BSOL2015-020178-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 Application Number: Property Address: APN: Application Description Property Zoning: Application Valuation: c&ty/ 4 4v COMMUNITY DEVELOPMENT DEPARTMENT BUILDING PERMIT BSOL2015-0201 54860 AVENIDA MADERO 774265028 VANDIVER /2.OkW PV SYSTEM - (8) 250W PANELS/(1) INVERTE $17,750.00 Applicant: UNITED FIELD REMODELING INC DBA ADDITION .17855 VANOWEN STREET RESEDA, CA 91335 D -LQ [N70 Q 2015 CIILA QUINTA COMMUNITY DB ELOPMENT DEPARTMENT LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, and my License is in full force and effect. License Class: B /License No.: 89621a=l:]� Date: -u1S Contractor. OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: (__j I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. (Sec.'7044, Business and Professions Code: The Contractors' State License Law does riot apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees; provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). ( ) I, as owner of the property, am exclusively contracting with licensed contractors to construct the project. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an Aver of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). (_) I am exempt under Sec. , B.&P.C. for this reason Date: Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Lender's I I I I IIII'I'I II'I 34 VOICE (760) 777-7125 FAX (760) 777-7011 INSPECTIONS (760) 777-7153 Date: 11/24/2015 Owner: . GWENDOLYN VANDIVER , 92253 Contractor: UNITED FIELD REMODELING INC DBA ADDITION 17855 VANOWEN STREET RESEDA, CA 91335 (818)784-2300 Llc. No.: 896912 WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of thew rk for which this permit is issued. I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier: _ Polity Number: _ I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, if I should become subject to the workers' compensation provisions of Section 3700 o e Labor Code, I shall forthwith comply with those provisions. Date: t/ Applicant: WARNING: FAILURE TO SECURE WORKERS'COMPENSATICVCOVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT: Application is hereby made to the Building Official for a permit subject to the conditions and restrictions set forth on this application. 1. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application , the owner, and the applicant, each agrees to, and. shall defend, indemnify and hold harmless the City of La Quinta, its.officers, agents, and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter upon the above-mentioned property for inspection purposes. Date: �1z Signature (Applicant or Agent): J :�>, '.F -p... ..'.f f: �' S-.lRe. :>-„. f+'.L '.ham: _Fi'?re yt%•� r�:'kispl9i s�R .a?t,.<�;A`5 - :.w'�`C 'Y .-r:s.y,;Ri✓,ee,.'. !{�-.A +c J: ATS 1 AINIOUNT�PAIDz DATE p fDESCRIPTION�k,' ��ACCOUNTCITY Mwl—xPAID BSAS SB1473 FEE ' # i 101-0000-20306 0' $1.00 $1.00 11/24/15 x''.:;i: s%"4t'. Pit, hwF... ."`{ °, r`"sX.q+n*:: y'^,.nx,',e?'"2�, ;??E” PAID BYE14 Ell y, �RECEIRT # :�$ `CHECK #1 CLTD Blf,� �METFIOD ;4.r .: n::. .. !M�` ,'?r. -..:....,..W._::u-��,P:....MM�.���.`�.;�,`��''�,:,r:.,r.�-"'v.:+>.,,��c1�3s4s���.E�<�,:�.:..�.m..Wii�'r..ewe..._.a':,dx,u;�@..a��.Wtlss�...7r�E:.:av:...-<7.3<..�sm<.,_�....r,�ts':. RYAN REYES % DEBIT 1111081 SGU Total Paid for BUILDING STANDARDS ADMINISTRATION.BSA: $1.00 "$1.00 DESCRTION .06 EMIR,*R .D PAI� Z ± DAT;mEG.;o;. .s.t.�, .. e PV SYSTEM - ARRAY, FIRST 20 t 101-0000-42403 • $24.17, $24.17 11/24/15 .0 ." �""• (�`.`s' S it '��f.kzE. T,L'�`, :yi> 4 #� L. CLTDBY. �.: x3PAID:BY� s , <METHODRECEIPT# € , ::.:;_ Ar «,,rCHECK J RYAN REYES DEBIT R11081 SGU X.fr ..:'S` `?" 'n _'b^ .'�:� y :+q � DESCRIPTION �" v >z% t8.. -.srV. -'k Y'�.,-n °..qa :' R'+'' j ACCOUNT C 0,#��F'.�r?�+•.r�?.:e='4{st"y'eA�.�a.'�T"��ios� CIR £ _:.. QTLY .' .' �`:.`-...'$i.' w`"i AMOUNTS^, .�.E+PAID-PAID:DATE; 'M.=F &t : i'?m �3t b3 •ArY<-Ra...,�..C,.. . PV SYSTEM - ARRAY, FIRST 20 PC 101-0000-42600 0 $24.17 $24.17 11/24/15 !' t•E:`ct 'k'-`, .Y"F6yf }�.�,{✓,'L#7,yy' PAIDBY:: %?*3`*, n:r .�".n'.w"�-?&�%'C?,4` b..,':ia 'i',<:'t AE -.:.'k.b% t 1evN5 RECEIPT , f, tl Y y'b.,h'ei$Et .:nw.fhsi•�::T,iFf. CLTDrBY rxrr,E �;.<<in°? .r�� .» MET�>t�` #�.,k CHECK¢# r.�E RYAN REYES DEBIT R13081 SGU ;� a ,� #: A3 M : v1:.. .. "">Z_ `t✓`. �� ,� DESCRIPTION" w+ •" s+°t�`s W ..:..:�,' tP"+� t � t;sr, ' ACCOUNT'S .s, }�t£YL['t; TY W(:' E.. ��� AMOUNT3a #_x`t .a's�`'t€�,�. PAID t ..""„ k PAID DATE `:' u. ,w'� �;r�'.�.-a;.-�, :&r�.pr.Q<,,:_.:°:.+:.k<.-.:..; .w:,.��. .``...!;:. S PV -SYSTEM --MISC EQUIPMENT' ' , 101-0000-42403 0 $24.17 .$24.17 11/24/15 .r '• . ,. :+A, -A ?eg� f .25 :�' `1irtY r59{%3o'Ail�dc Jt � .�'�.:r''�?�'G E'p'"� 11 v 4Si.-�§ J2 -...4E0' ��E � l �� RECEIPT # �3-.xP'!F A. 'S V f �TXrgr �*.x " � CHECK #� 5 k .'.;.may., k 4 4j$� ' CLTD BY= .t r r :skPAID:BY�'C� �YGb..%3sAw of3METHOD F R EY RYAN REYES DEBIT„ R11081 SGU DESCRIPTION t ? ACCOUNT 'rQTY AMOUNT `"`PAID i PAID DATE{'- x ��' "s ,..'��,_'(i.:v, . v4"��'".!.,$fia+3St,`Ap..v,'k.'t.'d�'i:+z�,Y.ii'.:d;f :tzhs� °.•.ksY'.Mil.'s Ek{:f,.�z€tt:.?k`(-:aLiB1,t+,',R'a°.'RE.;:4N ;" 3.,.!erf..`$,>,T'h'..w'%2i:Yv:.��aiE�i`t?:'L`. ..viii:-..E-..i,.ev..,.:'i PV SYSTEM-`MISC EQUIPMENT PC " 101-000042600 0 $24.17 $24.17 11/24/15 • nn :N-:Y}'�'G�rd'G�:, Ig.y$.;i3SyYA $'.St, V?S�m�y'-'�'S. z CPR 4, 4 4ij�.T¢E YG k`k t. xB PAID BY -,� F>�� �`��:�,. ��Y�4��:G:�:§€"t�yy"�;� •v `a .0 � L�Yz'E• METHOD .....E, .... „.; ..:.-L:fE:�£,E'S""stt"v SA'r {; RECEIPT # '.��{(,°%�''�T .. i_%14'Y l f�p �� '!±s � .}Xh' CHEGK�# 1. CLTD BY '%. o�'"`. rE:a•ir �s'sb.,_.si..&,_.�t�9n,�.3,..::.�3Rxx''9:.;&h 4 RYAN REYES DEBIT. R11081 SGU Total Paid,for-ELECTRICAL: $96.68 $96.68 —W ;yy' f4::Y : 5 ., :...v..X•.: { -Y n_y_}h,9,� ,{ i"w PN' _DESCRIPTION _G-£ ..w"PI'�.iv:•'u`T.{ - t' AMOUNTS 1y.z 4'F. 53 PAID A IPAID`DATE '"< F�ACCOUNT AQTY..py.j'' <.`�....+rtx- '<#x,1., F ♦ vi ,.:.a'�., is "'°- YSr_. y 4'•k,3'i-�,2 PERMIT ISSUANCE 101-0000-42404 0 $91.851 •$91.85 11/24/15 f X`Ffr 4b4_?"'d3kdf{ b' AL- Y.'*i t•:x�;._� .'_t . A:4ltye6:,:-'K4 3 'aPAID BYi��}r,G. x�b4 6:,:-' B'.YY.�" E-Si.S �. �eY ✓r { a �a�METI IOD+ •p.. ..,i' RECEIPT #f�� �"3CHECK # `d CLTD BYE &<..: .a _ •fi.k +i:t. Y,, .::� �6 f Ks ±y Y?:t T. , x�. �� ,�a' ': Y, '�' E ,Y: iF "e Ex»a ..._ •. t I'm °s...u.sa�:.%„AA.'e'u'a5.=5aR'E:s ,.,A 'k.. Q�� a YiiE2-.... '$'it7. kA'.ax s RYAN REYES ..DEBIT R11081 SGU Total -Paid for PERMIT ISSUANCE: $91.85 " . $91:85 • J s , e ; r , J • J Description: VANDIVER /2.OkW PV SYSTEM --(8) 25OW PANELS/(1) INVERTE Type: SOLAR Subtype: Status: APPROVED Applied: 10/6/2015 SGU Approved: 11/23/2015 LUR Parcel No: 774265028 Site Address: 54860 AVENIDA MADERO LA QUINTA,CA 92253 Subdivision: SANTA CARMELITA VALE LA QUINTA Block: 275 Lot: 19 Issued: UNIT 25 Lot Sq Ft:.0 Building Scl Ft: 0 Zoning: Finaled: Valuation: $17,750.00 Occupancy Type: Construction Type: Expired: No. Buildings: 0 No. Stories: 0 No. Unites: 0 Details: 2.OkW SOLAR ARRAY - (8) 25OW SOLARWORLD PANELS W/ (1)PVI-3.0-OUTD-US-AFCI INVERTER [120SF] 2013 CALIFORNIA ELECTRICAL CODE. Printed,: Tuesday, November 24, 2015 11:15:02 AM 1 of 3 - !?�L�■RJ_' .I LJ SYS TEti1S ADDITIONAL NOTES CHRONOLOGY TYPE Cl IRONOLOGY STAFF NAM E. ACTION DATE COMPLETION DATE PLAN CHECK PICKED UP STEPHANIE. GUM PERT 10/15/2015 10/15/2015 PLAN CHECK SUBMITTAL RECEIVED STEPHANIE GUMPERT 10/6/2015 10/6/2015 TELEPHONE CALL LUIS URIBE 10/14/2015 10/14/2015 LET BENTON KNOW 1ST REVIEW IS COMPLETE AND PLAN ARE READY FOR CORRECTIONS. TELEPHONE CALL LUIS URIBE 11/23/2015 .11/23/2015 SPOKE WITH ISSAC, PERMIT IS READY TO BE ISSUED CONDITIONS CONTACTS NAME TYPE NAME ADDRESSI CITY STATE ZIP PHONE FAX EMAIL APPLICANT UNITED FIELD REMODELING INC DBA ADDITION 17855 VANOWEN STREET RESEDA CA 91335 BENTON@EQUISOLAR. COM Printed,: Tuesday, November 24, 2015 11:15:02 AM 1 of 3 - !?�L�■RJ_' .I LJ SYS TEti1S Permit Details PERMIT NUMBER City of La Quinta BSOL2015-0201 NAME TYPE NAME ADDRESSI CITY STATE ZIP PHONE FAX EMAIL CONTRACTOR UNITED FIELD REMODELING INC DBA 17855 VANOWEN RESEDA CA 91335 BENTON@EQUISOLAR. ADDITION STREET COM OWNER GWENDOLYN VANDIVER 92253 Printed: Tuesday, November 24, 2015 11:15:02 AM 2 of 3 cyry SYSTEMS FINANCIAL INFORMATION CLTD DESCRIPTION ACCOUNT QTY AMOUNT PAID . ' . PAID DATE RECEIPT # CHECK # ~ METHOD PAID BY BY BSAS SB1473 FEE 101-0000-20306 0 $1.00 $1.00 11/24/15 R11081 DEBIT RYAN REYES SGU Total Paid for BUILDING STANDARDS ADMINISTRATION $1.00 $1.00 BSA: PV SYSTEM -ARRAY, 101-0000-42403 0 $24.17 $24.17 11/24/15 R11081 DEBIT RYAN REYES SGU FIRST 20 PV SYSTEM - ARRAY, 101-0000-42600 0 $24.17 $24.17 " 11/24/15 R11081 DEBIT RYAN REYES SGU FIRST 20 PC PV SYSTEM -MISC 101-0000-42403 0 $24.17 $24.17 11/24/15 R11081 DEBIT RYAN REYES SGU EQUIPMENT - PV SYSTEM -MISC 101-0000-42600 0 $24.17 $24.17 11/24/15 R11081 DEBIT RYAN REYES SGU EQUIPMENT PC Total Paid for ELECTRICAL: $96.68 $96.68 PERMIT ISSUANCE 101-0000-42404 0 $91.85 $91.85 11/24/15 R11081 DEBIT RYAN REYES SGU Total Paid for PERMIT ISSUANCE: $91.85 $91.85 s Printed: Tuesday, November 24, 2015 11:15:02 AM 2 of 3 cyry SYSTEMS Permit Details PERMIT NUMBER ' City of La Quinta BSO1�201450201 NON-STRUCTURAL - I LUIS URIBE 10/6/2015 10/13/2015 10/14/2015 REVISIONS REQUIRED 1 WK 1ST BLDG NS (1 WK) I LUIS URIBE 111/12/2015111/19/2015 11/23/2015 1 APPROVED Printed: Tuesday, November 24, 2015 11:15:02 AM 3 of 3 SYSTEMS Rin # Permit # a'�I � v Project Address: g6o Vel Qty of La. Quinta Buifding &' Safety Division 78-495 Calle Tampico La Quinta, CA 92253 - (760) 777-7012 Building Permit Application and Tracking Sheet Owner's Name: A. P. Number: Address:1/4 C11111 Legal Description: City, ST, Zip: -CA qaa�j H Contractor: Un- n Telephone: � minim Address: I� �' C ^ Project Description: City, ST, Zip:ItSt1,S !.'r7 K w Tele h ne: P0 d � y Z � State Lic. # : J City Lic. Arch., Engr., Designer: Address: City, ST, Zip: Telephone: ane Occupancy: Construction Y: Con tructi n Type: YP State Lic. #:Ject type one) Proja : New Add'n Alter Repair Demo Name of Contact Person: 6 cG Sq. Ft.: # Stories: # Units: Telephone # of Contact Person: Estimated Value of Project: APPLICANT: DO NOT WRITE BELOW THIS LINE # Submittal Req'd Rcc'd TRACKING PERMIT FEES Plan Sets Plan Check submitted Item 'Amount Structural Cafes. Reviewed, ready for corrections Plan Check Deposit Truss Cates. Called Contact Person Plan Check Balance Title 24 Calcs. Plans picked up Construction Flood plain plan . Plans resubmitted Mechanical Grading plan 2°" Revic%v, ready forcorrcctionsrssue Electrical Subcontactor List Called ContactPcrson Plumbing Grant Deed Plans picked up S.M.I. II.O.A. Approval Plans resubmitted Grading IN ROUSE:- Review, ready for corrcctionstiissue Developer Impact Fee Planning Approval Called Contact Person A.I.P.P. Pub. Wks. Appr Date of permit issue school Fees, Total Permit Fees i PHOTOVOLTAIC PLANS SCOPE OF WORK INSTALLATION OF A 2.0 KW ROOFTOP PHOTOVOLTAIC SYSTEM INCLUDING (8) MODULES AND (1) INVERTER. A NEW 200A MAIN SERVICE PANEL UPGRADE IS REQUIRED. GENERAL NOTES: 1. ALL EQUIPMENT SHALL BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURER'S APPROVED INSTALLATION METHOD 2. ALL EQUIPMENT AND WIRING SHALL BE LISTED BY UL OR A RECOGNIZED TESTING AGENCY BY THE LOCAL AHJ 3. USE MINIMUM 8 AWG EQUIPMENT GROUNDING CONDUCTOR (EGC) WHEN IT IS SUBJECT TO SUN EXPOSURE AND/OR WET LOCATION, OR INSTALL THE EGC IN AN APPROVED RACEWAY 4. ALL EXPOSED WIRING SHALL BE SUNLIGHT RESISTANT AND SUITABLE FOR WET CONDITIONS 5. ALL WORKING SPACES AND ACCESS ABOUT ELECTRICAL EQUIPMENT SHALL BE IN COMPLIANCE WITH NEC 110.26 6. THE INSTALLATION IS ONLY FOR UTILITY INTERACTIVE SYSTEMS AS SHOWN IN THE SINGLE LINE DIAGRAM 7. THE SHORT CIRCUIT CURRENT FOR 120/240V, SINGLE PHASE SERVICE THAT IS 0 - 225A, IS 10,000A OR IF 226 - 400A IS 22,000A 8. ALL ELECTRICAL EQUIPMENT INCLUDING THE SERVICE SHALL HAVE A LEGIBLE, VISIBLE, AND DURABLE MARKING INDICATING THE MANUFACTURER NAME, CURRENT, VOLTAGE, FREQUENCY, AND NUMBER OF PHASES 9. EACH INSTALLED EQUIPMENT, WIRING AND OVERCURRENT PROTECTIVE DEVICE (OCPD) SHALL HAVE A SHORT CIRCUIT RATING NOT LESS THAN THE AVAILABLE SHORT CIRCUIT CURRENT AT THEIR INPUT TERMINALS 10. THE MODULES SHALL BE MADE OF EITHER CRYSTALLINE OR MULTI CRYSTALLINE SILICON MATERIAL 11. ALL MODULES SHALL BE ROOF MOUNTED 12. THE MODULES RATINGS SHALL BE BASED ON SOLAR IRRADIANCE STANDARD TEST CONDITION (STC) OF 1000W/M^2 SYSTEM SIZE: 2.OKW DC / 1.7KW AC CEC PV EQUIPMENT LABELS AND NOTES: 1. ALL PV MODULES AND ASSOCIATED EQUIPMENT AND WIRING MATERIAL SHALL BE PROTECTED FROM ANY PHYSICAL DAMAGE 2. ALL PV SYSTEM COMPONENTS (EQUIPMENT AND WIRING) SHALL BE LISTED BY UL OR A RECOGNIZED TESTING AGENCY BY THE LOCAL AHJ 3. ALL WIRING MATERIAL SHALL BE SUITABLE FOR SUN EXPOSURE AND WET LOCATIONS 4. ALL FIELD INSTALLED JUNCTION, PULL AND OUTLET BOXES LOCATED BEHIND MODULES OR PANELS SHALL BE ACCESSIBLE DIRECTLY OR BY DISPLACEMENT OF A MODULE(S) OR PANEL(S) SECURED BY REMOVABLE FASTENERS. 5, THE ROOF MOUNTED PHOTOVOLTAIC MODULES, PANELS, OR SOLAR VOLTAIC ROLL ROOFING MATERIAL SHALL HAVE THE SAME OR BETTER LISTED FIRE -RESISTANCE RATING THAN THE BUILDING ROOF -COVERING MATERIAL 6. PHOTOVOLTAIC SYSTEM INSTALLATION SHALL COMPLY WITH THE NEC 690.61 REQUIREMENT, LOSS OF INTERACTIVE SYSTEM 7. EXPOSED NON-CURRENT CARRYING PARTS OF MODULE OR MODULE FRAMES, EQUIPMENT AND CONDUCTOR ENCLOSURE SHALL BE GROUNDED IN ACCORDANCE WITH NEC 250.134 OR 250.136(A) REGARDLESS OF VOLTAGE 8. REMOVAL OF AN EQUIPMENT FROM THE SYSTEM SHALL NOT DISCONNECT THE (EQUIPMENT GROUNDING) BONDING CONNECTION BETWEEN THE GROUNDING ELECTRODE CONDUCTOR AND EXPOSED CONDUCTING SERVICES BY MEANS OF A BONDING JUMPER, NEC 690.48 9. A BONDING JUMPER SHALL BE INSTALLED PRIOR TO REMOVAL OF A INTERACTICE INVERTER OR THE OTHER EQUIPMENT THAT DOES NOT DISCONNECT (REMOVE) TO MAINTAIN THE SYSTEM GROUNDING, NEC 690.49 10. LIVE PARTS IN PV SOURCE CIRCUITS AND PV OUTPUT CIRCUITS OVER 150V TO GROUND SHALL NOT BE ACCESSIBLE TO OTHER THAN QUALIFIED PERSONS WHILE ENERGIZED DESIGN REQUIREMENTS FOR ROOF MOUNTED SYSTEM: 1, DO NOT COVER (MECHANICAL OR PLUMBING) VENTS THROUGH THE ROOF WITH THE COLLECTOR PROJECT COMPLIES WITH • 2013 CALIFORNIA BUILDING CODE • 2013 CALIFORNIA RESIDENTIAL CODE • 2013 CALIFORNIA MECHANICAL CODE • 2013 CALIFORNIA ELECTRICAL CODE • 2013 CALIFORNIA PLUMBING CODE • 2013 CALIFORNIA ENERGY CODE • 2013 CALIFORNIA GREEN BUILDING CODE ` • LA QUINTA MUNICIPAL CODE ASSESSOR MAP CITY OF QUINTA BUILDING & SAFEN DPT. AF'PROVEON �i 3/(By - LOCATION OF PROJECT AREA OF WORK law Avenida Madel i ,4. R United Field Remodeling, Inc 17855 Vanowen Street Reseda, CA 91335 PH: (818) 784-2300 CONTRACTOR:A LIC# B-896912 LICENSE HOLD it Hagag SIGNATURE: Plans Designed by. Derek Brosch Date: 9/15/2015 Revision: A-10/21/15 Project: 15-09-185 ��'� v NOV 12 2015 � Y OF LA QUINTA LAITY DvVFLOPMF..,­ r 1 - TITLE SHEET O L M L (D > N 00 -0 O-) — U M C Q CMM) > (D C)'4^ > '0 Lo M N C) Q O L D Q0 ILI co 100 J A LO ECONCION AL AND SHOW BASIC SYSTEM OPERATION ONLY. IT IS SHOW BASIC INGS SYSTEMONLYS NOT INTENDED TO INCLUDE ALL DEVICES AND DETAILS NECESSARY FOR PROPER ORIENTATION. IT IS THE RESPONSIBILITY OF THE INSTALLING CONTRACTOR TO ENSURE THAT ALL NECESSARY DETAILS AND DEVICES ARE INSTALLED TO GUARANTEE PROPER OPERATION AND COMPLIANCE WITH LOCAL BUILDING CODES. `(vl THIS DOCUMENT CONTAINS PROPRIETARY INFORMATION AND ITS RECEIPT OR v \J\ POSSESSION DOES NOT CONVEY ANY RIGHTS TO REPRODUCE, DISCLOSE ITS CONTENTS. OTC ANYTHIN TO MANUFACTURE, USE, SELL MAY DESCRIBE. REPRODUCTION. DISCLOSURE OR USE WITHOUT SPECIFIC WRITTEN G IT AUTHORIZATION IS STRICTLY FORBIDDEN 1 - TITLE SHEET GENERAL NOTES: 1. LOCATIONS OF SERVICE PANEL AND ELECTRICAL EQUIPMENT COMPANY. 2. LOCATION OF SERVICE PANEL AND ADDITIONAL EQUIPMENT NOT DRAWN TO SCALE. 3. ADDITIONAL ELECTRICAL EQUIPMENT (INVERTER, AC DISCONNECT, ETC) IS WITHIN 10 FEET OF SERVICE PANEL. 4. PV EQUIPMENT SHALL BE INSTALLED IN ACCORDANCE WITH NEC 690 AND POSTED WITH APPLICABLE WARNINGS, SIGNAGE, AND PLAQUES PER NEC 705-10,690-17, & 690-64(bK5). 5. UTILITY HAS 24 -HR UNRESTRICTED ACCESS TO ALL PV SYSTEM COMPONENTS LOCATED AT SERVICE ENTRANCE 6. ORIENTATION OF HOUSE ON LOT WHERE SHOWN IS APPROXIMATE. LA QUINTA NOTES: 1. PHOTOVOLTAIC SYSTEM CONDUCTORS SHALL BE IDENTIFIED AND GROUPED. THE MEANS OF IDENTIFICATIONS SHALL BE PERMITTED BY SEPARATE COLOR CODING, MARKING TAPE, TAGGING, OR OTHER APPROVED MEANS. THE MEANS OF GROUPING SHALL BE WIRE TIES OR SIMILAR MEANS AT LEAST ONCE, AND THEN AT INTERVALS NOT TO EXCEED SIX (6) FEET. 2. PHOTOVOLTAIC EQUIPMENT AND SYSTEMS AND ALL ASSOCIATED WIRING AND INTERCONNECTIONS SHALL BE INSTALLED ONLY BY QUALIFIED PERSONS. 3. MATERIALS USED FOR MARKING SHALL BE REFLECTIVE, WEATHER RESISTANT AND SUITABLE FOR THE ENVIRONMENT, BE OF ALL CAPITALIZED LETTERS WITH A MINIMUM HEIGHT OF 3/8 INCH WHITE ON RED BACKGROUND 4. MARKING SHALL CONTAIN THE WORDS "WARNING: PHOTOVOLTAIC POWER SOURCE" 5. CONDUITS SHALL BE SPECIFICALLY MARKED EVERY 10 FEET, WITHIN 1 FOOT OF TURNS OR BENDS AND WITHIN 1 FOOT ABOVE AND BELOW PENETRATIONS OF ROOF/CEILING ASSEMBLIES, WALLS, OR BARRIERS. 98'-11 49'-8" PROPERTY LINE (:) SITE PLAN N.T.S. 101 W (8) SOLARWORLD 250W MODULES PROPERTY LINE .,Y, OF L, OUiN'TA C'' SAFETY DEPT. BUlLD1NGp ®V E® FOR CONSTRUCT — DATE�� United Field Remodeling, Inc 17855 Vanowen Street Reseda, CA 91335 PH: (818)1784-2300 CONTRACTOR: ICN B-896912 LICENSE HOLDE : He SIGNATURE: p Plans Designed by: Derek Brosch Date: 9/15/2015 Revision: A - 10/21/15 Project: 15-09-185 JI p 1` M N -0 N (0 U vaQ M ROOF RIDGE -0 i � V U . LU (/� (1) Cu (1) C D 3/4" EMT CONDUIT 0 m w ROUTED ACROSS � �=3 (0 Z LL ROOF & UNDER Cu O C) ti D OI'- EAVES (TYPICAL) m C� � J v o m L Lid O THESE DRAWINGS ARE CONCEPTUAL AND SHOW BASIC SYSTEM OPERATION ONLY. IT IS NOT INTENDED TO INCLUDE ALL DEVICES AND DETAILS NECESSARY FOR PROPER ORIENTATION. IT IS THE RESPONSIBILITY OF THE INSTALLING CONTRACTOR TO ENSURE THAT ALL NECESSARY DETAILS AND DEVICES - ABB 3.OKW ARE INSTALLED TO GUARANTEE PROPER (NEW) OPERATION AND COMPLIANCE WITH LOCAL INVERTER BUILDING CODES. THIS DOCUMENT CONTAINS PROPRIETARY (NEW) 30A SOLAR FORMATION NDITSRECEIPTOR IN POSSESSION DOES NOT CONVEY ANY RIGHTS AC DISCONNECT TO REPRODUCE, DISCLOSE ITS CONTENTS, OR TO MANUFACTURE. USE. OR SELL ANYTHING IT MAY DESCRIBE. REPRODUCTION, DISCLOSURE. OR USE WITHOUT SPECIFIC WRITTEN (NEW) 200A AUTHORIIATIONIS STRICTLY FORBIDDEN. ROOF PLAN MAIN SERVICE PANEL 2 - SITE PLAN ield Remodeling, Inc i Vanowen Street ;eda, CA 91335 (818) 784-2300 TOR: I A LICK B-896912 IOL : Nir Hagag E: ned by: Derek Brosch 9115/2015 A - 10/21/15 15-09-185 U C Fn d Eli ^O W � N (U (V 00 2a.)M. Cu Q M -2 0 cfl > CU Lr) QQ0 (0Cti 0o co qq- J L0 INGS ARE CONCEPTUAL AND SYSTEM OPERATION ONLY. IT IS D TO INCLUDE ALL DEVICES AND ESSARY FOR PROPER '. 1T IS THE RESPONSIBILITY OF NO CONTRACTOR TO ENSURE :ESSARY DETAILS AND DEVICES :D TO GUARANTEE PROPER ND COMPLIANCE WITH LOCAL )ES. :NT CONTAINS PROPRIETARY I AND ITS RECEIPT OR DOES NOT CONVEY ANY RIGHTS CE, DISCLOSE ITS CONTENTS, OR TORE, USE, OR SELL ANYTHING IT IE. REPRODUCTION, DISCLOSURE, OUT SPECIFIC WRITTEN ON IS STRICTLY FORBIDDEN. ROOF PLAN SYSTEM DETAILS: (8) SOLARWORLD 250W MODULES (1) PVI-3.0-OUTD-US (240V) STC: 8 x 250W = 2,000 W DC CEC: 8 x 222.3 x 0.96 =1,707 W AC CEC STRING #1: (8) SOLARWORLD 250W MODULES PV PV PV PV MODULE MODULE MODULE MODULE --J -- 77 \------= J OCPD BREAKER SIZE CALCULATIONS: INVERTER MAX OUTPUT CURRENT X 125% 14.5A X 125%= 18.1A, 20A OCPD BREAKER USED 120% RULE CALCULATIONS PER NEC: BOTTOM FED MAIN BREAKER BUSBAR X 100% - MAIN BREAKER > SOLAR BREAKER 200A (BUSBAR) x 120% - 200A (MAIN BREAKER) = 40A 40A BACKFEED CURRENT AVAILABLE A 200A MAIN SERVICE PANEL UPGRADE IS REQUIRED PV MODULE RATINGS QTY CONDUCTOR INFORMATION O(2) SW 250 MONO #10 AWG PV WIRE IN FREE AIR (1) #6 AWG BARE COPPER GND IN FREE AIR MAX POWER POINT VOLTAGE(Vmp) 31.1V #10 AWG THWN-2 O(2) (1) #8 AWG THWN-2 GN IN 34' EMT O(3) 0.87 #10 AWG THWN-2 (1) #8 AWG THWN-2 GN IN 34' EMT ONEW GROUNDING SYSTEM, #6 AWG EGC OCPD BREAKER SIZE CALCULATIONS: INVERTER MAX OUTPUT CURRENT X 125% 14.5A X 125%= 18.1A, 20A OCPD BREAKER USED 120% RULE CALCULATIONS PER NEC: BOTTOM FED MAIN BREAKER BUSBAR X 100% - MAIN BREAKER > SOLAR BREAKER 200A (BUSBAR) x 120% - 200A (MAIN BREAKER) = 40A 40A BACKFEED CURRENT AVAILABLE A 200A MAIN SERVICE PANEL UPGRADE IS REQUIRED PV MODULE RATINGS MAKE SOLARWORLD MODEL SW 250 MONO MAX POWER 250W OPEN CIRCUIT VOLTAGE (Voc) 37.8V MAX POWER POINT VOLTAGE(Vmp) 31.1V SHORT CIRCUIT CURRENT(Isc) 8.28A MAX POWER POINT CURRENT(Imp) 8.05A GROUNDING TYPE NEGATIVE ARRAY RATINGS MAKE LOWEST HISTORIC TEMP. -7" C # OF MODULES IN SERIES 8 Voc @ LOWEST TEMP. 338.7V Vmp 248.8V Isc 8.28A Imp 8.05A (NEW) 3.0KW 1 T SOLAR INVERTER W/INTEGRATED AFCI ROOF -MOUNTED _ JUNCTION BOX 1 INTEGRATED MPPT1 DC (NEW) _ — MPPT2 DISCONNECT 3 PERFORMANCE 3 METER FOR -------------� ® IID L— fl INVERTER RATINGS MAKE ABB MODEL PVI-3.0-OUTD-US (240V) MAX OUTPUT POWER 330OW MAX DC VOLTAGE 600V NOMINAL AC VOLTAGE 240V MAX AC CURRENT 14.5A CEC INVERTER EFFICIENCY 96% AFCI PROTECTION INTEGRATED PANEL UPGRADE NOTE: • SERVICE PANEL WILL BE UPGRADED FROM A 100A SERVICE TO A 200A SERVICE. A METER SPOT WILL BE PERFORMED BY UTILITY PRIOR TO UPGRADING THE PANEL. • AN ELECTRICAL PERMIT MUST BE OBTAINED BEFORE ANY WORK CAN COMMENCE ON UPGRADING THE PANEL. 20A SOLAR BREAKER (NEW -PV BREAKER SHALL BE LOCATED ON THE OPPOSITE SIDE OF MAIN SERVICE PANEL) (NEW) 30A LOCKABLE 3 NONFUSED r OUTDOOR AC �-}- DISCONNECT CITY OF LA QUIDNTPA BUILDING �®��® APP FOR CONSTRUCTION DATE BY -- Wire Run fl > BIDIRECTION m Minimum Wire Size Calculations (a) 900C c N INCOMING UTILITY D Circuit Max 125% 156% Temp. Fill Factor Conduit Fill Required DC Min. AC Wire Wire Type DC/AC Current Factor Factor Correction Correction Correction Wire Ampacity Size 41 C+22 C 41eC Ampa city Wire Ampacity Derated Ampacity String #1 to J -box DC 8.28 12.92 - 1 0.87 12.92 #10 Cu 40 34.80 w ,,Nmoiome Manu :.L T• 'Wnwrm+-Aw .4" O 00 ca � J J -box to Inverter #1 DC 8.28 12.92 0.65 0.8 - 12.92 #10 Cu 40 20.80 Inverter #1 to Main Service AC 14.50 18.13 - 0.65 1 0.87 - 18.13 #8 Cu 55 47.85 BOTTOM FED MAIN SERVICE PANEL 200A MAIN BREAKER I (NEW) o fl > BIDIRECTION m METER c N INCOMING UTILITY D VOLTAGE: M 120V/24OV, 1 cp, 3W HelioLug LIC# B-896912 UL.27o3E338690 QIM57 $;'al' aj'F,& 9 0: Hagag Included Components 1) Lay fn lug (iin plated sollcJ_coper lay -fn tug with a.stainless-sieel_set'screwj 2� Siair{Cess;star;4iash®i' Date: 3) S1alNess`"sfeel;tigll; 4)'Stairilgis:seerrated_looic nut'. , i� Y 5 qb.F. t npr 15-09-185 M Co 0i� HOWLO Ord•f c� h w ,,Nmoiome Manu :.L T• 'Wnwrm+-Aw .4" O United Field Remodeling, Inc 17855 Vanowen Street Reseda, CA 91335 PH: (818) 784-2300 CONTRACTOR: LIC# B-896912 LICENSE HOLDI Hagag SIGNATURE: Plans Designed by: Derek Broach Date: 9/152015 Revision: A - 1021115 Project: 15-09-185 a) L_ -0 CO N (0 (o Q U M Co 0i� � c� •=3 C O 00 ca � J THESE DRAWINGS ARE CONCEPTUAL AND SHOW BASIC SYSTEM OPERATION ONLY. IT IS NOT INTENDED TO INCLUDE ALL DEVICES AND DETAILS NECESSARY FOR PROPER ORIENTATION. IT IS THE RESPONSIBILITY OF THE INSTALLING CONTRACTOR TO ENSURE THAT ALL NECESSARY DETAILS AND DEVICES ARE INSTALLED TO GUARANTEE PROPER OPERATION AND COMPLIANCE WITH LOCAL BUILDING CODES. THIS DOCUMENT CONTAINS PROPRIETARY INFORMATION AND ITS RECEIPT OR POSSESSION DOES NOT CONVEY ANY RIGHTS TO REPRODUCE, DISCLOSE ITS CONTENTS. OR TO MANUFACTURE, USE. OR SELL ANYTHING IT MAY DESCRIBE. REPRODUCTION, DISCLOSURE. OR USE WITHOUT SPECIFIC WRITTEN AUTHORIZATION IS STRICTLY FORBIDDEN. 4 - SINGLE LINE DIAGRAM United Field Remodeling, Inc 17855 Vanowen Street Reseda, CA 91335 PH: (818) 784-2300 CONTRACT CA LIC# B-896912 LICENSE HO D R: Nir Hagag SIGNATURE: Plans Design y: Derek Brosch Date: 9/162015 Revision: A - 10/21/15 Project: 15.09.185 a) THESE DRAWINGS ARE CONCEPTUAL AND SHOW BASIC SYSTEM OPERATION ONLY. ITIS NOT INTENDED TO INCLUDE ALL DEVICES AND DETAILS NECESSARY FOR PROPER ORIENTATION. IT IS THE RESPONSIBILITY OF THE INSTALLING CONTRACTOR TO ENSURE THAT ALL NECESSARY DETAILS AND DEVICES ARE INSTALLED TO GUARANTEE PROPER OPERATION AND COMPLIANCE WITH LOCAL BUILDING CODES. THIS DOCUMENT CONTAINS PROPRIETARY INFORMATION AND ITS RECEIPT OR POSSESSION DOES NOT CONVEY ANY RIGHTS TO REPRODUCE. DISCLOSE ITS CONTENTS. OR TO MANUFACTURE. USE. OR SELL ANYTHING IT MAY BILL OF MATERIALS -BARBARA VANDIVER EQUIPMENT QTY DESCRIPTION SOLAR PV MODULE 8.00 SOLARWORLD SW250 MONO N ap INVERTER 1.00 ABB PVI-3.0-OUTD-US (240V) AC DISCONNECT 1.00 30A, 240V, NEMA 3R, UL LISTED SOLAR LABELS PER PLANS SOLAR LABELS ATTACHMENTS (COMP SHINGLE) 14.00 PROSOLAR FAST JACK -E SERIES FLASHING 14.00 FLASHING FOR FAST JACKS RAILS 6.00 PROSOLAR 2-1/2" RAILS- 12' SECTION RAIL SPLICE 5.00 SPLICE KIT MID CLAMPS 16.00 PROSOLAR MID CLAMPS -CLEAR END CLAMPS 6.00 PROSOLAR END CLAMPS -CLEAR GROUNDING LUGS 15.00 HELIOLUG United Field Remodeling, Inc 17855 Vanowen Street Reseda, CA 91335 PH: (818) 784-2300 CONTRACT CA LIC# B-896912 LICENSE HO D R: Nir Hagag SIGNATURE: Plans Design y: Derek Brosch Date: 9/162015 Revision: A - 10/21/15 Project: 15.09.185 a) THESE DRAWINGS ARE CONCEPTUAL AND SHOW BASIC SYSTEM OPERATION ONLY. ITIS NOT INTENDED TO INCLUDE ALL DEVICES AND DETAILS NECESSARY FOR PROPER ORIENTATION. IT IS THE RESPONSIBILITY OF THE INSTALLING CONTRACTOR TO ENSURE THAT ALL NECESSARY DETAILS AND DEVICES ARE INSTALLED TO GUARANTEE PROPER OPERATION AND COMPLIANCE WITH LOCAL BUILDING CODES. THIS DOCUMENT CONTAINS PROPRIETARY INFORMATION AND ITS RECEIPT OR POSSESSION DOES NOT CONVEY ANY RIGHTS TO REPRODUCE. DISCLOSE ITS CONTENTS. OR TO MANUFACTURE. USE. OR SELL ANYTHING IT MAY L 0 -Cu CO U7 N > s` U (6 N ap C cu Q co cv a� > c CO cu 0 m (0C) o cu. LID DESCRIBE. REPRODUCTION, DISCLOSURE, OR USE WITHOUT SPECIFIC WRITTEN AUTHORIZATION IS STRICTLY FORBIDDEN. 5 —BILL OF MATERIALS SYSTEM SIGNAGE ALL SIGNAGE SHALL BE IN PLASTIC, RED IN COLOR WITH WHITE LETTERING, AND ATTACHED WITH APPROVED ADHESIVE. ALL LETTERS SHALL BE A MINIMUM OF 3/8" HEIGHT AND ALL CAPITALIZED. REQUIRED WARNI-NG LABELS PLACE ON ALL CONDUIT, LOCATED ON ROOF, INTERIOR AND EXTERIOR, EVERY 10' AT TURNS AND ABOVE AND/OR BELOW PENETRATIONS AND ALL DC COMBINER AND JUNCTION BOXES IN %" WHITE LETTERING ON RED BACKGROUND, ON FADE RESISTANT MATERIAL CAUTION: SOLAR CIRCUIT NEC 690.54 PLACE THIS LABEL AT "POINT OF INTERCONNECTION" (ON THE COVER OF THE MAIN SERVICE PANEL) CAUTION INTERACTIVE PHOTOVOLTAIC POWER SOURCE RATED AC OUTPUT CURRENT (A): 14.5A NOMINAL OPERATIONAL AC VOLTAGE (V): 240V NEC 690.14(C)(2) PLACE THIS LABEL ON THE AC DISCONNECTING MEANS NEC 690.64(B)(7) PLACE THIS LABEL AT POC TO SERVICE DISTRIBUTION EQUIPMENT (NEXT TO THE SOLAR BREAKER INSIDE THE PANEL) NEC 690.17 PLACE THIS LABEL ON ALL DISCONNECTING MEANS WHERE ENERGIZED IN AN OPEN POSITION WARNING ELECTRIC SHOCK HAZARD DO NOT TOUCH TERMINALS TERMINALS ON BOTH LINE AND LOAD SIDE MAY BE ENERGIZED IN THE OPEN POSITION NEC 690.5(C) PHOTOVOLTAIC AC DISCONNECT PLACE THIS LABEL ON INVERTER(S) OR NEAR GROUND FAULT INDICATOR NEC 690.53 PLACE THIS LABEL ON THE INVERTER SYSTEM RATINGS RATED MAX POWER POINT CURRENT (Imp): 8.05A RATED MAX POWER POINT VOLTAGE (Vmp): 248.8V MAX SYSTEM VOLTAGE (Voc): 338.7V SHORT CIRCUIT CURRENT (Isc): 8.28A PLACE THIS LABEL AT "AC DISCONNECT" (ON THE COVER OF THE AC DISCONNECT) CAUTION: SOLAR ELECTRIC SYSTEM CONNECTED WARNING ELECTRIC SHOCK HAZARD IF A GROUND FAULT IS INDICATED NORMALLY GROUNDED CONDUCTORS MAY BE UNGROUNDED AND ENERGIZED WARNING INVERTER OUTPUT CONNECTION DO NOT RELOCATE THIS OVERCURRENT DEVICE CAUTION: POWER TO THIS BUILDING IS ALSO SUPPLIED FROM THE FOLLOWING SOURCES WITH DISCONNECTS LOCATED AS SHOWN AT: METER AND wo MAIN SERVICE a AC DISCONNECT < DC DISCONNECT o INVERTER z w Q MARKING CONTENT AND FORMAT ❑ RED BACKGROUND ❑ WHITE LETTERING ❑ MINIMUM 3/8" LETTER HEIGHT ❑ ALL CAPITAL LETTERS ❑ ARIAL OR SIMILAR FONT, NON—BOLD ❑ WEATHER RESISTANT MATERIAL SUITABLE FOR THE ENVIRONMENT (DURABLE ADHESIVE MATERIALS MUST MEET THIS REQUIREMENT United Field Remodeling, Inc 17855 Vanowen Street Reseda, CA 91335 PH: (818) 784-2300 CONTRACTOR: A IC# B-896912 LICENSE HOLDE Hagag SIGNATURE: Plans Designed by: Derek Brosch Date: 9/152015 Revision: A - 10121115 Project: 15-09-185 CITY OF LA QUINTA BUILDING SAFETY DEPT. APP OVED FOR COSTRUCTION N O -0 M LO N > -0 C0 . a)2a-5 to CN 00 4- >w-204 (UQM (� N 0CU > C O (u(� O m co Cu d' LO J THESE DRAWINGS ARE CONCEPTUAL AND SHOW BASIC SYSTEM OPERATION ONLY. IT IS NOT INTENDED TO INCLUDE ALL DEVICES AND DETAILS NECESSARY FOR PROPER ORIENTATION. IT IS THE RESPONSIBILITY OF THE INSTALLING CONTRACTOR TO ENSURE THAT ALL NECESSARY DETAILS AND DEVICES ARE INSTALLED TO GUARANTEE PROPER OPERATION AND COMPUANCE WITH LOCAL BUILDING CODES. THIS DOCUMENT CONTAINS PROPRIETARY INFORMATION AND ITS RECEIPT OR POSSESSION DOES NOT CONVEY ANY RIGHTS TO REPRODUCE. DISCLOSE ITS CONTENTS. OR TO MANUFACTURE. USE. OR SELL ANYTHING IT MAY DESCRIBE. REPRODUCTION. DISCLOSURE. OR USE WITHOUT SPECIFIC WRITTEN AUTHoFuzAnON IS STRICTLY FORBIDDEN. 6 - SIGNAGE & PLACARD Sunmodule" - SW 250 mono /Version 2.0 and 2.5 Frame World-class quality ,,1�,,e 1) Fully -automated production lines and seamless monitoring of the process �� a Clualifled. IEC 61215 and material ensure the quality that the company sets as its benchmark for V� - 31.1 V Safety IEC DQE Its sites Worldwide. Maximum power point current '51C: 1000W/m•, 25%. AM 1.5 Periodic Inspection IEC Design Loads' Two rail system . _ _. ' °aaool"•°va SolarWorld Plus -Sorting Plus -Sorting guarantees highest system efficiency. SolaMorld only delivers modules that have greater than or equal to the nameplate rated. power. 25 years linear performance guarantee and extension of product warranty to 10 years SolarWorld guarantees a maximum performance depression of 0.7% p.a. in the course of 25 years, a significant added value compared to the two-phase warranties common in. the industry. In addition, SolarWorld is offering a product warranty, which has been extended to 10 years' -in accordance with the applicable SolarWorld Limited Warranty at purchase. www.solarworld.com/warranty www.solarworld.com 11900, 9001 O 14001 �,�/ x,71 fj IS Certified C UL US LISTED rnorwouac xoom. r io„e i Mad. in USA Jjwii SOLARWORLD We turn sunlight into power. Sunmodule" - SW 250 mono/ Version 2.0 and 2.5 Frame PERFORMANCE UNDER STANDARD TEST CONDITIONS (STC)' THERMAL CHARACTERISTICS INOCT SW 250 Maximum power P 250 Wp Open circuit voltage V„ 37.8 V Maximum power point voltage V� - 31.1 V Short circuit current 1% 8.28A Maximum power point current '51C: 1000W/m•, 25%. AM 1.5 -.-•+Its.--.- --+.+•-+8.05A THERMAL CHARACTERISTICS INOCT ' 46Y) TC 1„ 0.004 %/K Cell dimensions -0.30 %/K TCD -0.45 %/K Operatmgtemperature -40'C to 85'C Fv uwes" satukror4d sW LW efenasi I I • • 2SYeo0 teriisit 16YD . _ . _. .90 rp40 f0-�.fiioYC/u!. .0 ':ID'.+ .7D {3D- •"DW carniaM J 65.94 ill= am :rsion 5 frame Atom ounting Aes SW-02-SOOIUS 07.2012 PERFORMANCE AT 800 W/ml, NOCT, AM 1.5 SW 250 Maximum power _ _ P_ 183.3 Wp Open circuit voltage V. 34.6V Maximum power point voltage V. 28.SV Short circuit current Iu6.68 A Maximum power point current •- -: »- +�-l- -».++_.m 6.44A mo°` Minor reduction in efficiency under parllal load conditions at 25•C: at 20OW/m•.95% (+/.3%) of the STC efficiency (1000 W/m+) is achieved. COMPONENT MATERIALS Cells per module 60 Cell type Mono crystalline Cell dimensions 6.14 in x 6.14 in (156 mm x 156 mm) Front tempered glass (EN 12150) Frame Clear anodized aluminum Weight 46.7 lbs (21.2 kg) SYSTEM INTEGRATION PARAMETERS Maximum system voltage SC II 100ov] Max. system voltage USA NEC 600 V Maximum reverse current 16 A Number of bypass dlodes 3 UL Design Loads' Two rail system 113 psf downward 64 psf upward UL Design Loads' Three rail system 170 psf downward 64 psf upward IEC Design Loads' Two rail system . _ _. 113 psf downward _ _ _ 50 psf upward •Please refer to the Sunmodule installation instructions for the details associated with these load cases. ADDITIONAL DATA Powertolerance'l -0 Wp/+5 Wp J-BoxIP65 Connector MC4 Module efficiency 14.91% Fire rating (UL 790) cm;7I 0.6 15.3 0.6 15.3 ID_7 "1 I VERSION 2.0 FRAME VERSION 2.5 FRAME x4 Compatible with 'Top -Clown' Compatible with both 'Top -Down' 0 (107)1 mounting methods and "Bottom' mounting methods • ♦Grounding Locations: ♦Grounding Locations: 4 corners of the frame - 4 corners of the frame - 4 locations along the length of the module in the extended flanget 1) Sunmodules dedicated for the United States and Canada are tested to UL 1703 Standard and listed by a third party laboratory. The laboratory may vary byproduct and region. Check with your SolarWorld representative to confirm which laboratory has a listing for the product. 2) Measuring tolerance traceable to TUV Rheinland: +P 2% (TUV Power Controlled). 3) All units provided are imperial. SI units provided in parentheses. SolarWorld AG reserves the right to make specification changes without notice United Field Remodeling, Inc 17855 Vanowen Street Reseda, CA 91335 PH: (818) 784-2300 CONTRACTOR LIC# B-896912 LICENSE HOL R 'r Hagag SIGNATURE: Plans Designed by: Derek Brosch Date: 9/152015 Revision: A - 10/21/15 Project: 15-09-185 U W 0 n W 1790 0 CU2 ICU C (0 co LO N 00 M U Ce) co 0 //O••�� • =3(/ LL CU J THESE DRAWINGS ARE CONCEPTUAL AND SHOW BASIC SYSTEM OPERATION ONLY. IT IS NOT INTENDED TO INCLUDE ALL DEVICES AND DETAILS NECESSARY FOR PROPER ORIENTATION. IT IS THE RESPONSIBILITY OF THE INSTALLING CONTRACTOR TO ENSURE THAT ALL NECESSARY DETAILS AND DEVICES ARE INSTALLED TO GUARANTEE PROPER OPERATION AND COMPLIANCE WITH LOCAL BUILDING CODES. THIS DOCUMENT CONTAINS PROPRIETARY INFORMATION AND ITS RECEIPT OR POSSESSION DOES NOT CONVEY ANY RIGHTS To REPRODUCE. DISCLOSE ITS CONTENTS. OR TO MANUFACTURE. USE. OR SELL ANYTHING 1T MAY DESCRIBE. REPRODUCTION. DISCLOSURE. OR USE WITHOUT SPECIFIC WRITTEN AUTHORIZATION IS STRICTLY FORBIDDEN. 7 - DATA SHEET This family of single-phase string The high-speed MPPT offers real - inverters complements the typical time power tracking and improved number of rooftop solar panels energy harvesting. enabling homeowners to get the most The flat efficiency curve ensures high efficient energy harvesting for the size efficiency at all output levels allowing of the property. a consistent and stable performance Start: uP..voltage.(Vstart).................... .............. ............ .......................................................................... across the entire input voltage and This inverter offers a dual input output power range. section that processes two strings The transformerless operation gives the with independent Multiple Power Point highest efficiency of up to 97.0 percent. Tracking (MPPT). The wide input voltage range makes This is especially useful for rooftop the inverter suitable to low power installations with two different installations with reduced string size. orientations from two sub -arrays This rugged outdoor inverter has been oriented in different directions or designed to be a completely sealed unbalanced strings (For example: East unit able to withstand the harshest and West). environmental conditions. The dual -input sections with independent MPPT enable a more 12.5A optimal energy harvesting condition. .....16A...................... 20.OA Highlights: — Single-phase and three-phase output grid connection — Wide input -voltage range for increased stringing flexibility and energy harvesting — The high speed and precise MPPT algorithm offers real-time power tracking and improved energy harvesting — Outdoor NEMA 4X rated enclosure for unrestricted use under any environmental conditions — Integrated DC disconnect switch in compliance with international Standards (-S Version) Power and productivity „ 1111 for abetter worldTM P+,.'. Additional highlights: — RS -485 communication interface (for connection to laptop or data logger) — Integrated Arc Fault Detection and Interruption (-A Version) Technical data and types Type code PVI-3.0-OUTD-US PVI-3.6-OUTD-US PVI-3.8-OUTD-US 0iVI-4.2-cium-US - - — - - ---- - ._ .. . IMedhahlcal specifications _ _ Nominal output power 3000W 360OW 3W0 3800W 420OW !­!&6'0f"':00 Maximum output power wattage %Ai w w . VV %Ar VV w w w \Ar w w Number of independent MPPT channels i LICENSE HOLD 2 2 2 ............ _......... .............._........_2..........................i Maximum usablo power for oach channel 2000W ................................... ...... -. 3000W..................I.................. _3000W................... ......... ......... .........3000W......... ..... Absolute maximum voltage (Vmax)... .... ................................. ... .................600V ......... ...... ....................... -... ... ......... _ Start: uP..voltage.(Vstart).................... .............. ............ .......................................................................... Q U .... ......._200V..(adl..,i 20350V)...... ..... ........... ..........,......................... ..... ......... .............. Full power MPPT voltage range ..................... ......... ........ ...._160 -530V.................`..................1_0 ........ -530V 140-530V ........................._....................................................................... 140.530V ........... ..... Operating MPPT voltage range ......................................................... 0.7 x Vstart - 580V (a90V) ... ........... .................. ....................................................... Cy ___... Maximum current (Idcmax) for both Mftt'T in 20A 32A 32A 32A arallel .P....................................................................................................:.......................................................!......................................................;............................................................................................................ Maximumusable current per channel J ...........................................10A.............................................16A.......................i....................._16A.......................................I Maximum short circuit current Ilmlt per 12.5A 20.OA 20.OA .....16A...................... 20.OA channel ............................................................................................................ ... ....................................................... ...... _....................................................................... Numberof wire lending terminals,per channel...:............ ................................................................................ _2..Pairs............. ....... ,..................... ..... ........ .... .....-............. .... Arrav wirino termination Terminal block. oressure clamp. AWG20-AWG6 Grid connection type ...... ................-............... ,............. .................................. ... Adjustable voltage range (Vmin-Vmax) (V) Maximum current (I.,,,,,) rated 1. Capability enabled at nominal AC Voltage and min sulflGent DC power available. 2 ABB Solar Inverters I Product flyer for PVI-3.0/3.6/3.8/4.2-TL-OUTD ............................................................................................................................................................... 57-60.5Hz ' ....1p7.2..:....1 ....!Ma .... .... !�aus....i.....!?r.Ms....?..._Aanw....i_._A.rws....'.... A.ws....'..._AaMs.._i..._Asu s.... i....%?a.s.... > 0.995 ................................................................................................................................................................ .................. .................. .............. .2.% ............. .................. .................. .................. ................. .................. ........................................................ . Varistor, 2 (Lr - L / LI - 25A,,,< 97% ....................................96%............ < 0.6Wn..< < 8Wn 16 characters x 2 lines LC[ VSN700 Data Loqqer 6 D +140°F (.25'C to, 60°C) with. dera ..................... ..- ...... .... -40°F to +176°F (-40"C, to ............. I.... _....................... RH condens .................. ........... ....0-100% ....................................... . ...................................<50db(A)@1m United Field Remodeling, Inc 17855 Vanowen Street Reseda, CA 91335 PH: (818) 784-2300 B-896912 CONTRACTOR:*irI'agag LICENSE HOLD N -0 SIGNATURE: Plans Designed by: Derek Brosch Date: 9/152015 Revision: A - 10/21/15 Project: 15-09-185 r1 LTJ N N -0 CO N > CU U M 2 TNT M X00 V > � (U � Q U M '^�'' W > CD LO O Cy co 00 ICU � J THESE DRAWINGS ARE CONCEPTUAL AND SHOW BASIC SYSTEM OPERATION ONLY. IT IS NOT INTENDED TO INCLUDE ALL DEVICES AND DETAILS NECESSARY FOR PROPER ORIENTATION. IT IS THE RESPONSIBILITY OF THE INSTALLING CONTRACTOR TO ENSURE THAT ALL NECESSARY DETAILS AND DEVICES ARE INSTALLED TO GUARANTEE PROPER OPERATION AND COMPLIANCE WITH LOCAL BUILDINGCODES. THIS DOCUMENT CONTAINS PROPRIETARY INFORMATION AND ITS RECEIPT OR POSSESSION DOES NOT CONVEY ANY RIGHTS TO REPRODUCE. DISCLOSE ITS CONTENTS, OR TO MANUFACTURE, USE, OR SELL ANYTHING IT MAY DESCRIBE. REPRODUCTION, DISCLOSURE. OR USE WITHOUT SPECIFIC WRITTEN AUTHORIZATION IS STRICTLY FORBIDDEN. 8 - DATA SHEET �, Integrated with Fast Jack' attachments ooRTrac 7be patented Roof Trac' system installed urith the Fast Jacks Patent 86.360.491 attacbment method provides an ideal sohitio'n for installations The Original "Top -Down" PV Mounting System. where aflashingrsdesfired.7beFa,stjackOisalso the solar industries preferred method of attachment for new construction roofs. Root ttac®9 rant Jack'" protected patens under Latent #6,360,491 8 Otheepatents Other pendlrg. Tile Trac® protected under Patent #S,646,029. professional (800) 84 -SOLAR SCOL^ n (805) 383 -0804 -fax /�V� 4630 Calle Quetzal products Camarillo, CA 93012 For more iri/brrnation you can visit us on the web at www.RoojTrac.com Thc Hast Jack attachment provides a quick attd snnTtg h7siallcttionsolutiom Ourpatented design places the holt directly under the stanchion post where it provides the most support. .his fea- utre allows standard roofflashittgs to lay flat on the twf deck. The removable post allows tlt4,d5irtgs to be slipped over the base tvilbow damaging surronndirkg composi- tion shingle. E� i A _ V '7 l rj� Third Party 1 Lab Tested d 0 I loa 3,600 lbs Uplial load 1380 lbs' Side f Tested 111kWat'lroo om 7; W49 Fa 5 tJa ck U 12703 ` Fastfack® Structural RoofAttachment 0- with New Aluminum Flashing and Collar Irttertek "See 90 second real-time complete install video at www.prosolar.com" Available in: C 2' tall FastJackO E -Series Part #FJE-200 3" tall Fast,lackO E -Series Part #FJE-300 4-1/2" tall Fast.lacke E -Series Part #FJE450 FasUack0 E -Series Flashing 8 Collar Part #FJE-Flash Benefits of Fastjack-and Fastjack-Flashing • Lowest cost, highest quality • Solid aluminum post prevents water flow • 90 second install time through post into roof • Includes Lag screw and ProSolar rail • Heavy-duty 0.032" aluminum flashing attachment hardware thickness • Black powder -coated flashing and collar The Fastjack® Design • Patented, single lag bolt design makes it the easiest to install attachment • 2 piece design allows flashing to easily slip over base, prior to post • Flashing design prevents water ingress from any direction • Made in U.S.A., American Recovery and Reinvestment Act (ARRA) compliant United Field Remodeling, Inc 17855 Vanowen Street Reseda, CA 91335 PH: (818) 784-2300 CONTRACTOR: IC# B-896912 LICENSE HOLDE i ag SIGNATURE: Plans Designed by: Derek Brosch Date: 9/15/2015 Revision: A-10/21/15 Project: 15-09.185 N O -0 M N �7 4 (U U 1 C (U '2 Q CU N/ttshated above k; bow the Fasl Jack' ulktchinott seandmvlt) integrates u4lb All at/acbment batdware s`c concealed the RooJ'7htc. mounting syslem. untbin the support ritil leaving an (Mnlheticall v pleasing solar array. >�. Splice Kit �.. � Me splice kil provides a solution to rigidly lock multiple rail i�o_ sets togelher. The splice kit has a feature that allows for ther- mal arpan ion/cantrachon of the tails without damaging O � the roof -top! professional (800) 84 -SOLAR SCOL^ n (805) 383 -0804 -fax /�V� 4630 Calle Quetzal products Camarillo, CA 93012 For more iri/brrnation you can visit us on the web at www.RoojTrac.com Thc Hast Jack attachment provides a quick attd snnTtg h7siallcttionsolutiom Ourpatented design places the holt directly under the stanchion post where it provides the most support. .his fea- utre allows standard roofflashittgs to lay flat on the twf deck. The removable post allows tlt4,d5irtgs to be slipped over the base tvilbow damaging surronndirkg composi- tion shingle. E� i A _ V '7 l rj� Third Party 1 Lab Tested d 0 I loa 3,600 lbs Uplial load 1380 lbs' Side f Tested 111kWat'lroo om 7; W49 Fa 5 tJa ck U 12703 ` Fastfack® Structural RoofAttachment 0- with New Aluminum Flashing and Collar Irttertek "See 90 second real-time complete install video at www.prosolar.com" Available in: C 2' tall FastJackO E -Series Part #FJE-200 3" tall Fast,lackO E -Series Part #FJE-300 4-1/2" tall Fast.lacke E -Series Part #FJE450 FasUack0 E -Series Flashing 8 Collar Part #FJE-Flash Benefits of Fastjack-and Fastjack-Flashing • Lowest cost, highest quality • Solid aluminum post prevents water flow • 90 second install time through post into roof • Includes Lag screw and ProSolar rail • Heavy-duty 0.032" aluminum flashing attachment hardware thickness • Black powder -coated flashing and collar The Fastjack® Design • Patented, single lag bolt design makes it the easiest to install attachment • 2 piece design allows flashing to easily slip over base, prior to post • Flashing design prevents water ingress from any direction • Made in U.S.A., American Recovery and Reinvestment Act (ARRA) compliant United Field Remodeling, Inc 17855 Vanowen Street Reseda, CA 91335 PH: (818) 784-2300 CONTRACTOR: IC# B-896912 LICENSE HOLDE i ag SIGNATURE: Plans Designed by: Derek Brosch Date: 9/15/2015 Revision: A-10/21/15 Project: 15-09.185 N O -0 M N (U U >a) (U '2 Q CU M "t i i�o_ �=3ICU C) O � m � ca L J THESE DRAWINGS ARE CONCEPTUAL AND SHOW BASIC SYSTEM OPERATION ONLY. IT IS NOT INTENDED TO INCLUDE ALL DEVICES AND DETAILS NECESSARY FOR PROPER ORIENTATION. IT IS THE RESPONSIBIUTY OF THE INSTALLING CONTRACTOR TO ENSURE THAT ALL NECESSARY DETAILS AND DEVICES ARE INSTALLED TO GUARANTEE PROPER OPERATION AND COMPLIANCE WITH LOCAL BUILDING CODES. THIS DOCUMENT CONTAINS PROPRIETARY INFORMATION AND ITS RECEIPT OR POSSESSION DOES NOT CONVEY ANY RIGHTS TO REPRODUCE. DISCLOSE ITS CONTENTS, OR TO MANUFACTURE. USE. OR SELL ANYTHING IT MAY DESCRIBE. REPRODUCTION, DISCLOSURE, OR USE WITHOUT SPECIFIC WRITTEN AUTHORIZATION Is STRICTLY FORBIDDEN. 9 - DATA SHEET