BRES2016-036978-495 CALLE TAMPICOU VOICE (760) 777-7125 FAX (760) 777-7011 LA QUINTA, CALIFORNIA 92253 DESIGN & DEVELOPMENT DEPARTMENT INSPECTIONS (760) 777-7153 BUILDING PERMIT Date: 12/23/2016 Application Number: BRES2016-0369 Owner: Property Address: 81020 GOLF VIEW DR CORY MCCULLOCH APN: 762280031 Property Zoning: Application Valuation: $32,000.00 Applicant: 0 a Contractor: ALL DAY HEATING & COOLING INC D ALL DAY HEATING & COOLING INC 82=578 PISA LANE 2 3 2016 82-578 PISA LANE INDIO, CA 92203 DEC INDIO, CA 92203 CITY pF �,QUINT�EpARTMENT (760)834-1064 pESIGN AND DEVEI.�pMENT Llc. No.: 1008011 LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Busines and Professions Code, and my License is in full force and effect. Liceen�n`se,Class: C20 License No.: 100088011 De: 23 I L Contractor: V OWNER -BUILDER DECLARATIO I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions_of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: (_) I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). (_) I, as owner of the property, am exclusively contracting with licensed contractors to construct the project. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). (_) I am exempt under Sec. . B.&P.C. for this reason Date: Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Lender's Address: WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of Jhg work for which this permit is issued. wave and will maintain workers' compensation insurance, as required by Section'3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier: NORGUARD INSURANCE COMPANY Policy Number: ALWC784110 _ I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, if I shouldbecome subject to the workers' compensation provisions of Section 37 0 of the or ode, I shall forthwith comply with those provisions. 11112e:! %Zt25 t C� Applicant: WARNING: FAILURE TO SECURE WORKERS'COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT: Application is hereby made to the Building Official for a permit subject to the conditions and restrictions set forth on this application. 1. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application , the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents, and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances ands to laws rel in building construction, and hereby authorize representatives of this ty to en te 'the above- mentioned property for inspection ppurposes. : k Signature (Applicant or Agent): I Date: 12/23/2016 Application Number: BRES2016-0369 Owner: Property Address: 81020 GOLF VIEW DR CORY MCCULLOCH APN: 762280031 Property Zoning: Application Valuation: $32;000.00 Applicant: Contractor: ALL DAY HEATING & COOLING INC ALL DAY HEATING & COOLING INC 82-578 PISA LANE 82-578 PISA LANE INDIO, CA 92203 INDIO, CA 92203 (760)834-1064 Llc. No.: 1008011 -.------------------------------------------------------------------------------------------ Detail: HVAC CHANGE OUT - 4 SPLIT SYSTEM HVAC UNITL 16EER/80AFUE, 1 TANKLESS WATER HEATER [2013 ENERGY] CARBON MONOXIDE ALARM(S) TO BE INSTALLED PRIOR TO FINAL INSPECTION. 2013 CALIFORNIA BUILDING CODES. 0 FINANCIAL INFORMATION DESCRIPTION ACCOUNT QTY AMOUNT BSAS SB1473 FEE 101-0000-20306 0 $2.00 Total Paid for BUILDING STANDARDS ADMINISTRATION BSA: $2.00 DESCRIPTION ACCOUNT QTY AMOUNT CONDENSER/COMPRESSOR 101-0000-42402 0 $152.00 DESCRIPTION ACCOUNT QTY AMOUNT CONDENSER/COMPRESSOR PC 101-0000-42600 0 $101.32 Total Paid for MECHANICAL: $253.32 DESCRIPTION ACCOUNT QTY AMOUNT PERMIT ISSUANCE 101-0000-42404 0 $96.27 Total Paid for PERMIT ISSUANCE: $96.27 DESCRIPTION ACCOUNT QTY AMOUNT WATER HEATER CHANGEOUT 101-0000-42401 0 $12.67 DESCRIPTION ACCOUNT QTY AMOUNT WATER HEATER CHANGEOUT PC 101-0000-42600 0 $7.60 Total Paid for PLUMBING FEES: $20.27 DESCRIPTION ACCOUNT QTY AMOUNT SMI - RESIDENTIAL 101-0000-20308 0 $4.16 Total Paid for STRONG MOTION INSTRUMENTATION SMI: $4.16 DESCRIPTION ACCOUNT QTY AMOUNT TECHNOLOGY ENHANCEMENT FEE 502-0000-43611 0 $5.00 Total Paid for TECHNOLOGY ENHANCEMENT FEE: $5.00 G' Bin Qty of La Qu«nta Building 8£ Safety Division Permit # 78-495 Calle Tampico La Quinta, CA 92253 - (760) 777-701,2 Building Permit Application and Tracking Sheet Project Address: 1 — v t� ��, .� wner's Name: A. P. Number: Address: G oL—:p Legal Description: Contractor: >L� City, ST, Zip: Z Tel h n G T O e o e: C P Address: �Z .5 Project Description: City_ ST, Zip:��7 O 3 Tele6 P hn e: �—1 a G z State Lic. # : (L(c� 'F—Cj i Arch.,'Engr., Designer: City Lie. #.. �J Address: tS City, ST, Zip: Telephone: one: a to ,. St Lie. i�. L • Name of Contact Person: tru ane Cons c t ion TY Occupancy: P O P Y= Pr Ject type circle one): New Add'n Alter Repair Demo. Sq. Ft.:#Stories: #Units: Telephone # of Contact Person: stimated Value of Project: a' pC_,--)cD APPLICANT: DO NOT WRITE BELOW THIS LINE # Submittal Req'd Rcc'd TRACKING PERMIT FEES Plan Sets Plan Check submitted Item Amount Structural Cafes. Reviewed, ready for corrections Plan Check Deposit Truss Calcs. Called Contact Person Plan Check Balance Title 24 Calcs. Plans picked up Construction ' Flood plain plan Plans resubmitted Mechanical Grading plan 2°" Review, ready for corrcctions/issue Electrical . SubcontactorList Called Contact Person Plumbing Grant Deed Plans picked up S.M.I. H.O.A. Approval Plans resubmitted Grading IlY ROUSE:- Jrd Reyiew, ready for corrections/issue Developer Impact Fee Planning Approval Called Contact Person A.I.P.P. Pub. Wks. Appr Date of permit issue School Fees, Total Permit Fees .N CERTIFICATE OF COMPLIANCE CF1R-ALT 02-E Alterations to Space Conditioning Systems (formerly CF -1R -ALT -HVAC) (Page 1 of 4 ) Project Name: 81-020 Golf View Drive I Date Prepared: 2016-12-19 A. General Information CF1R-ALT-02 is applicable to multiple space conditioning systems contained within a single dwelling unit. When multiple dwelling units must be documented, use one CF1R-ALT-02 document for each dwelling unit. O3 Project Name 81-020 Golf View Drive 02 Date Prepared 2016-12-19 03 Project Location 81-020 Golf View Drive 04 Building Type - Single family 05 CA City La Quinta 06 Dwelling Unit Name 81-020 Golf View Drive 07 Zip Code 92253 08 Dwelling Unit Conditioned 3400 nstallirig I I stalli g `Installing Floor Area (ft2) Location or Area by this SC `ducted containing M fs 16 system Number of space conditioning enn ely w 09 Climate Zone 15 10 (SC) systems in this dwelling 4 component? components? feet of ducts? duct system? unit. Alteration Type B. Space Conditioning (SC) System Information 01 02 03 04.*� 05� 1 706 1 �N 1 1 07 )� W 08) `� 09 10 Is the SC""" Installin a 1l SC System SC System CFA served system a re rf iger nt 4 Installing new SC nstallirig I I stalli g `Installing Identification or Location or Area by this SC `ducted containing M fs 16 system more than 40 enn ely w entirely new Name Served System (ft2) system? component? components? feet of ducts? duct system? SC system? Alteration Type System 1 kitchen 1200 Yes Yes Yes No No No Altered space conditioning system System 2 guest bedrooms 900 Yes Yes Yes No No No Altered space conditioning system System 3 master bedroom 900 Yes Yes Yes No No No Altered space conditioning system System 4 casita room 400 Yes Yes Yes No No No Altered space conditioning system Registration Number: 216-A0467098A-000000000-0000 CA Building Energy Efficiency Standards - 2013 Residential Compliance Registration Date/Time: 2016-12-19 09:02:27 Report Version: 2013 Rev 1.008 Schema Version: 0.555SDD HERS Provider: Ca10ERTS Report Generated: 2016-12-19 07:42:48 CERTIFICATE OF COMPLIANCE CF1R-ALT 02-E Alterations to Space Conditioning Systems (formerly CF -1R -ALT -HVAC) (Page 2 of 4 ) C. Extension of Existing Duct System, Greater Than 40 Feet (Section150.2(b)1Diib) This section does not apply to this project. D. Altered Space Conditioning System (Sections 150.2(b)lE and F) 01 02 03 04 05 06 07 08 09 10 11 12 Heating Cooling System Heating Altered Heating Minimum Altered Cooling Minimum Required New or Identification System Heating Efficiency Efficiency Cooling Cooling Efficiency Efficiency Thermostat Replaced New Duct or Name Type Components Type Value System Type Components Type Value Type Duct Length R -Value Central gas All new Central split All new This field or This field or System 1 furnace heating AFUE 80 AC cooling SEER 16 Setback section is not section is not components components applicable applicable Central gas All new Central split All new This field or This field or System 2 furnace heating AFUE 80 AC cooling SEER 16 Setback section is not section is not components ;components'- applicable applicable 3 Central gas All new heating AFUE f I 80 ',1 1 € .1 ^Central splitSystem �y `- LAII�new\►. iEER f tsil i 16 Setback This field or section is not This field or section is not furnace +-- . components components`.:•L applicable applicable Central gas All new : ! All new °'" This field or This field or System 4 furnace heating AFUE 80Central_split AC cooling SEER 16 Setback section is not section is not components components I applicable applicable Reouired Documentation: CF2R-MCH-01-E - Space Conditioning Systems Ducts and Fans -Duct insulation requirement for new plenums: R6. CF2R-MCH-20-H & CF311-MCH-20-H — Duct Leakage testing required when heating or cooling components are installed in ducted systems, or when more than 40 ft of duct length is replaced. -Leakage rate compliance:!g 15%, or:5 10% leakage to outside, or seal all accessible leaks. CF2R-MCH-25-H & CF3R-MCH-25-H Refrigerant Charge Verification required when refrigerant containing components are installed or altered (applicable in CZ 2, 8-15). CF2RCF3R-MCH-23 & CF3R-MCH-23 Air Flow 2 300 CFM/ton required when MCH -25 is required. Exceptions: -Duct systems registered with HERS provider as previously sealed are exempt from MCH -20 Duct Leakage Testing requirements. -Heating-only systems and Air Handler/Furnace changes do not require verification of Air Flow MCH -23, or Refrigerant Charge MECH-25. -Existing duct systems constructed, insulated or sealed with asbestos are exempt from MCH -20 Duct Leakage Testing requirements. Registration Number: 216-A0467098A-000000000-0000 CA Building Energy Efficiency Standards - 2013 Residential Compliance Registration Date/Time: 2016-12-19 09:02:27 Report Version: 2013 Rev 1.008 Schema Version: 0.555SDD HERS Provider: CalCERTS Report Generated: 2016-12-19 07:42:48 A. . .y r \4 W, CERTIFICATE OF COMPLIANCE CUR -ALT -024 Alterations to Space Conditioning Systems (formerly CF -IR -ALT HVAC) (Page 3 of 4 ) E. Entirely New or Complete Replacement Duct System, with or without Equipment Changeout (Sections 150.2(b)iDiia and 150.2(b)1E, F) This section does not apply to this project. F. Entirely New or Complete Replacement Space Conditioning System (Section 150.2(b)1C) This section does not apply to this project. . Registration Number: 216-A046709BA-000000000-0000 C ao CERTS, nc. HERS PROi1I DER Registration Date/Time: 2016-12-19 09:02:27 HERS Provider: CalCERTS CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version: 2013 Rev 1.008 Report Generated: 2016-12-19 07:42:48 Schema Version: 0.555SDD CERTIFICATE OF COMPLIANCE CF1R-ALT 02-E Alterations to Space Conditioning Systems (formerly CF -IR -ALT -HVAC) (Page 4 of 4 Documentation Author's Declaration Statement 1.1 certify that this Certificate of Compliance documentation is accurate and complete. Documentation Author Name: Documentation Author Signature: SANCHEZ, MIGUEL Company: Signature Date: MIGUEL SANCHEZ 2016-12-19 07:42:04 Address: CEA/ HERS Certification Identification (if applicable): 83947 Moonlit Drive City/State/Zip: Phone: Coachella CA 92236 760-834-1064 Responsible Person's Declaration statement I certify the following under penalty of perjury, under the laws of the State of California: 1. The information provided on this Certificate of Compliance is true and correct. 2. 1 am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design or system design identified on this Certificate of Compliance (responsible designer). 3. That the energy features and performance specifications, materials, components, and manufactured devices for the building design or, system design identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of Regulations 11 i .I k ,,,, 4. The building design features or system design features identified on this Certificate of Compliance are consistent with the Information provided on other applicable compliance documents, worksheets, calculations, plans and specifications submitted to the enforcement agency for approval'with this building permit application. 5. 1 will ensure that a registered copy of this Certificate of Compliance shall be made available with the building Permits) issued for..the building; and made available to the—enforcement agency for all applicable inspections. I understand that a registered copy of this Certificate of Compliance is required to be included with the documentation the builder provides to the building owner at occupancy. Responsible Designer Name: `+� : I tf. . r A w 7 Responsible Designer Signature: V 0 � j��� 9-N Sanchez, Miguel Company: Date Signed: ALL DAY HEATING & COOLING INC 2016-12-19 09:02:27 Address: License: 82-578 PISA LANE 1008011 City/State/Zip: ' Phone: INDIO CA 92203 760-834-1064 X123 Digitally signed by CaICERTS. This digital signature is provided in order to secure the content of this registered document and in noway implies Registration Provider responsibility for the accuracy of the information. Registration Number: 216-A0467098A-000000000-0000 Registration Date/Time: 2016-12-19 09:02:27 HERS Provider: CaICERTS CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version: 2013 Rev 1.008 Report Generated: 2016-12-19 07:42:48 Schema Version: 0.555SDD STATE OF CALIFORNIA RESIDENTIAL ALTERATIONS — WATER HEATER CEC-CFIR-ALT-01-E (Revised 06114) CALIFORNIA ENERGY COMMISSION CERTIFICATE OF COMPLIANCE CF1R-ALT-01-E WATER HEATER Prescriptive Residential Alterations for Water Heater (Page 1 of 2) A. GENERAL INFORMATION Site address: 8 t _ Building Type: Single Family Dwelling ❑ Multi Family Dwellings City, Zip Code: ONTARIO, CA Climate Zone: 10 G. WATER HEATING SYSTEMS Section 150.2 b 1G 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 Water Water Water # of Water Fuel Rated Rated Heating Heating Standby Exterior Back -Up Central Dwelling Heating Heating Heater Water Heater Type Input Input Efficiency Efficiency Loss (%) Insul. Solar DHW System Unit DHW System System Type Heaters Storage Type Value Type Value R -Value Savings Distribution System Identification Type in Volume Fraction Type Distribution or system (gal) Type Name pJa Q I o,.--) T�1 C1 o,,k ( t3 (a �C�.S `�'J I kkK 10 CaL o'fo fJ l V 4 N A 1 Ernck, WATER HEATING SYSTEMS Water heating compliance for an alteration is described in Section 150.2(b)1G. For single dwelling a gas or propane water heater, with a storage tank of 60 gallons maximum or instantaneous (tarikless) can be used. Dwelling Unit distribution systems are limited to Standard trunk and branch or demand recirculation for gas or propane water heater. Demand recirculation is not allowed for electric water heater. If there is no natural gas connected to the building, an electric water heater may be replaced with another electric water heater. However, changing from gas to electric is not allowed. Multi -family central systems must use certified equipment as defined under Section 110.1 and 110.3. NOTE: If the proposed installation does not meet the requirements allowed specifically for alterations, use form CFIR-NCB-01 to document the water heater alteration. Instructions for sections with column numbers are given below: 1. Water Heating System Identification or Name: enter a unique name for the Water Heating System. 2. Water heating system type: Domestic Hot Water (DHW), Hydronic, Combined Hydronic, or Central. DHW is for domestic hot water, hydronic is a water heating system used for space heating only; combined hydronic are when the water heater will provide both space conditioning and domestic hot water. 3. Water heater type: For non -central systems only Small Storage or Small Instantaneous are allowed. For central systems pick from Large Storage, Small Storage, Heat Pump, Boiler, Large Instantaneous, Small Instantaneous or Indirect. CERTIFICATE OF COMPLIANCE C11`111 -ALT -01-E WATER HEATER Prescriptive Residential Alterations for Water Heater (Page 2 of 2) 4. Number of water heaters in system: In single-family and multi -family with water heaters in each dwelling units the value is 1. For multi -family central systems serving multiple dwelling units enter the total number of water heaters. 5. Water heater volume (gal): tank capacity in gallons. For individual water heaters for a dwelling unit this will be 60 gallons or less. If instantaneous, enter n/a. For multi -family central systems enter the total storage volume. 6. Fuel Type: Gas, Propane, Electric (Only if natural gas is not available) 7. Rated Input Type: Enter the equipment input rating type, for gas or propane fired units are Btuh, for electric fired system the units are kW. 8. Rated Input Value: Enter the numeric value of rated input. 9. Heating Efficiency Type: Energy Factor, AFUE, or Thermal Efficiency. From product literature ora California Energy Commission directory. 10. Heating Efficiency Value: Enter the value from product literature or a California Energy Commission directory 11. Standby Loss (percent): Applies only to large storage water heaters, Enter n/a for small storage or instantaneous water heaters. 12. Exterior Insulation R -Value: Enter the R -value if exterior insulation on the storage tank is installed 13. Back-up solar savings fraction: If compliance requires a back-up solar system, indicate the solar contribution (e.g., 0.30). External calculations are required. 14. Central DHW Distribution System: For multi -family buildings with using a central distribution system a demand recirculation system with at least two distribution loops must be installed. This requirement applies to any building with eight or more units. If the system is non -central or project is individual units enter n/a. 15. Dwelling Unit DHW Distribution Type: For a Central DHW this field shall be Standard. If non -central then pick from Standard, Demand Recirculation — Manual Control, Demand Recirculation — Sensor Control. If non -central electric water heater this must be Standard, no recirculation system shall be installed. DOCUMENTATION AUTHOR'S DECLARATION STATEMENT • I certify that this Certificate of Compliance documentation is accurate and complete. Name: ❑Owner . ❑ Authorized agent -4ontractor Signature: Company Contractor license #: %=,O t�� t Address: � Z_S Phone: City/State/Zip: . Date: For assistance or questions regarding the Energy Standards, contact the Energy Hotline at: 1-800-772-3300. r- STATE Old CAL�,-ORNIA ALTERATIONS - HVAC L2t CEC-CFIR-ALT-04-E Revised 06/14 CALIFORNIA ENERGY COMMISSION CERTIFICATE OF COMPLIANCE CFIR-ALT-04-E Alterations - HVAC CZ 2, and 8-15 (formerly CF -IR -ALT -HVAC) (Page 1 of 1) Site Address:// 61. Enforcement Agency: Date Prepared:. Permit#: ,23 (_o'.).,o — T_- v< <-'v Equipment Type Equipment Efficiency New Ducting, Plenums, Lineset: Conditioned Thermostat Required R -value Floor Area (sq ft) ❑ Packaged System ❑ Evaporator Coil AFUE COP ❑ R-6 (CZ 8-13) Ducting 1, Served by system ❑ Setback ❑ Split System ❑ Condensing Unit ❑ R-8' (CZ 11, 14, 15) Ducting 3 0tv, sgft (if not already P Mini Split ❑ Compressor ) 9j SEER HSPF ❑ R-6 (all CZ's) Plenums present must ❑ Furnace ❑ Lineset EER ❑ R-5 or R7.5) Lineset' be installed) ❑ TXV HERS VERIFICATION SUMMARY Installer determines work to be completed and matches to one of the.options below. At permit application this form is allowed to be filled out by hand. For final inspection all forms are to be registered (no hand filled forms allowed) and a copy left on site. ,'1. HVAC Changeout/Repair Required Compliance Documents to be left on site for Final: All Equipment, CF111-ALT-02-E Condenser Unit, Evaporator Coil, CF2R: MECH-01, MECH-20-HERS, MECH-(23 or 24)2 -HERS, MECH-25-HERS2 Compressor, TXV, Lineset, CF3R: MECH-20-HERS, MECH-(23 or 24)-HERS2, MECH-25-HERS2 Air Handler/Furnace' (Can include new ducting) Installer Requirement: Duct leakage (< 15%, or < 10% to outside, or seal all accessible leaks), Air Flow 2 300 CFM/ton, Refrigerant Charge. Exempted from duct leakage testing if: ❑ 1. Duct system registered with HERS provider as previously sealed, or ❑ 2. There is less than 40 linear feet of duct in unconditioned space, or ❑ 3. Existing duct systems are constructed, insulated or sealed with asbestos (list manufacture date of building ❑ 2. New HVAC System Required Compliance Documents to be left on site for Final: All new equipment and All New Ducts' CFIR-ALT-02-E including Mini Split CF2R: MECH-01, MECH-20-HERS, MECH-22-HERS, MECH-(23 or 24) -HERS', MECH-25-HERS2 CF3R: MECH-20-HERS, MECH-22-HERS, MECH-(23 or 24)-HERS2, MECH-25-HERS2 Mini Splits require CFIR-ALT-02-E, CF2R-MECH-01, and (CF2R-CF3R) MECH-25-HERS Installer Requirement: Duct leakage < 6%, Fan Efficacy (.58W/CFM), Air Flow 2 350 CFM/ton (or alternative), Refrigerant Charge ❑ 3. All New Ducts with Replacement Required Compliance Documents to be left on site for Final: All New Ducts' and one or more of the following CF1R-ALT-02-E replaced: Condenser Unit, Evaporator Coil, CF2R: MECH-01, MECH-20-HERS, MECH-(23 or 24) -HERS, MECH-25-HERS Compressor, TXV, Lineset, Furnace2 CF3R: MECH-20-HERS, MECH-(23 or 24) -HERS, MECH-25-HERS Installer Requirement: Duct leakage < 6%, Air Flow >_ 350 CFM/ton (or alternative), Refrigerant Charge Exempted from duct leakage testing if: ❑ 1. Existing duct systems are constructed, insulated or sealed with asbestos ❑ 4. New Ducting over 40 feet Required Compliance Documents to be left on site for Final: New ducting but less than All New Ducts' I CF111-ALT-02-E, CF2R: MECH-20-HERS, CF3R: MECH-20-HERS Installer Required to: Duct leakage (!S_15% or, < 30% to outside or, or seal all accessible leaks) ❑ EXCEPTION: Existing duct systems constructed, insulated or sealed with asbestos. 'All new ducting R-8 required when more than 40 ft installed and R-6 when less than 40 ft installed. This includes in walls, between floors etc. 2 Heating only systems and Air Handler/Furnace changes do not require Air Flow MECH-(23 or 24), or Refrigerant Charge verification MECH-25 3 All New Ducts is when at least 75 percent of the duct system is new duct material, and up to 25 percent may consist of reused parts from the dwelling unit's existing duct system (e.g., registers, grilles, boots,.air handler, coil, plenums, duct material) ° R-5 (1" thick insulation) for linesets 1" and less. R-7.5 (1.5" thick insulation) for linesets over 1 inch. Most mfg will require Suction line Diameter with insulation as the following 1.5-2T-2%", 2.5-3T-2%", 3.S to 4T-2%", 5T-4%." Contractor (Documentation Author's /Responsible Designer's Declaration Statement) I certify the following under penalty of perjury, under the laws of the State of California: 1. The information provided on this Certificate of Compliance is true and correct. 2. 1 am eligible under Division.3 of the California Business and Professions Code to accept responsibility for the information on this document. 3. That the energy features and performance specifications for the design identified on this Certificate of Compliance conform to the requirements of Title 24, Parts 1 and 6 of the California Code of Regulations (CCR). 4. That the energy features and performance specifications, materials, components, and manufactured devices for the building design or system design identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the CCR. 5. The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents, worksheets, calculations, plans and specifications submitted to the enforcement agency for approval with this building permit applic tion. Responsible Designer Name: Responsible De er Sign u e:Dat Signed: License: t 0a Company: Address: City/State/Zip: P ne: 46,L-c- �a--( �1E re T 5 C > ._ d 2-S� v ,5 4:;7-3 _,> I — (--I& o o�J�-I - t o C. For assistance or questions regarding the Energy Standards, contact the Energy Hotline at: 1-800-772-3300