Loading...
10-1425 (SFD)P.O. BOX 1504 78-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 c&t!t4 40" BUILDING & SAFETY DEPARTMENT BUILDING PERMIT Application Number: 10-00001425— Property Address: 77490 CALLE ARROBA AP N: 774-115-012-12 -000000- Application description: DWELLING - SINGLE FAMILY DETACHED Property Zoning: COVE RESIDENTIAL Application valuation: 99448 Applicant: Architect or Engineer: 0�� LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professionals Code, and my License is in full force and effect. License Class: License No.: Date: Contractor: OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred.dollars ($500).: (_ 1 I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). (�_ 1 I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). (_ 1 I am exempt under Sec. - , BAP.C. for this reason Date: d ' CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of p jury that there is a construction lending agency for the performance of the work for which this permit is issu d (Sec. 9 , Civ. C.). - k4 Lender's Name: Q Lender's Address: r LQPERMIT Owner: KNALL CHRISTIAN 4224 LA SALLE AVENUE CULVER CITY, CA 90232 Contractor: Owner VOICE (760) 777-7012 FAX (760) 777-7011 INSPECTIONS (760) 777-7153 Date: 4/26/11 LAQP 2 G 201,1 � 'I Y_ i I� CITOf � A'f3UIN ------------------ WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: _ I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. _ I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier Policy Number _ I certify that, in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, if I should become subject to the workers' compensation provisions of Section L 3700 of the Labor Code, I shall ort�hw�ithcommply with those provisions. Date: 2! plicant: 1A71IC�_ _ WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the conditions and restrictions set forth on this application. 1 . Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application, . the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. ' I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives oft i county to enter upon the above-mentioned property for insp tion pur os Date: ok 12,61 Sig ura (Applicant or Agent): Application Number . . . . . *10-00001425 ------ Structure Information 1,_514SF DWELLING/VB/RES-3/CL A [ENG] ----- Other struct info . . CODE EDITION 2007/2008 # BEDROOMS 3..00 . FIRE SPRINKLERS no GARAGE SQ FTG 536.00 PATIO SQ FTG. 176:00 NUMBER OF UNITS 1.00 ---------------------=------------------------------- 1ST FLOOR SQUARE FOOTAGE. ----------------------- 1514.00 Permit BUILDING PERMIT Additional desc . Permit Fee . . . . 639:5.0. Plan Check Fee 415.68 Issue Date Valuation 99448 Expiration Date 10/23/11 Qty Unit Charge Per Extension BASE FEE 414..50 50.00 4.5000 ---------------------------------------------------------------------------- THOU BLDG 50,001-100,000 22.5.00 Permit MECHANICAL Additional desc . Permit Fee .71.00 Plan Check Fee 17.75 Issue Date Valuation . . . . 0 Expiration Date 10/23/11 Qty Unit Charge Per Extension BASE FEE 15.00 1.00 9.0000 EA MECH FURNACE <=100K 9.00 1.00 4.5000 EA MECH VENT INST/ DUCT ALT 4.50 1.00 16.5000 EA MECH B/.0 >3-15HP/>100K-500KBTU 16.50 3.00' 6.5000 EA MECH VENT FAN 19.50 1.00 6.5000 ---------------=------------------------------------------------------------ EA MECH EXHAUST HOOD 6.50 Permit . . . ELEC-NEW RESIDENTIAL Additional des_c. Permit Fee . . . . 93.71 Plan Check Fee 23.43 Issue Date . . . . Valuation . . . . 0 Expiration Date 10/23/11 Qty Unit Charge Per Extension BASE.FEE 15.00 1514.00 0350 ELEC NEW RES - 1 OR 2 FAMILY 52.99 536.00 .0200 ELEC GARAGE OR NON-RESIDENTIAL- 10.72 1.00 15.0000.EA ELEC TEMPORARY POWER POLE 15.00 LQPERMIT Application Number . . . . 10-00.001425. ---------------------------------------------------------------------------- Permit PLUMBING Additional desc . Permit Fee 139.50 Plan Check Fee 34.88' Issue Date Valuation .0 Expiration Date 10/23/11 Qty Unit Charge Per Extension .. BASE FEE 15.00 12.00 6.0000 EA PLB FIXTURE 72.00 1.00 15.0000 EA PLB BUILDING SEWER 15.00 1.00 7.5000 EA PLB WATER HEATER/VENT _7.50 1.00 3.0000 EA PLB WATER INST/ALT/REP 3.00 1.00• 9.0000 EA PLB LAWN SPRINKLER SYSTEM. 9.00 1.00 3.0000 EA PLB GAS PIPE -1-4 OUTLETS 3.00 1.00 15.0000 EA PLB GAS METER 15.00. Permit GRADING PERMIT Additional desc . Permit Fee . . . . 15.00 Plan Check Fee .00 Issue Date Valuation 0 Expiration Date 10/23/11 Qty Unit Charge Per Extension BASE FEE =------------------------- 15.00 ---------------------=--------------------- Special Notes and Comments ------- 1,514SF DWELLING/VB/RES-3/CLASS A -FR (ENGINEERED] FINISHED FLOOR ELEVATION ' SHALL BE (12) INCHES MAXIMUM FROM DATUM POINT ON AVENIDA OBREGON. THIS PERMIT DOES NOT INCLUDE BLOCK WALLS, POOL AND SPA, OR DRIVE WAY APPROACH. 2007 CALIFORNIA.BUILDING/200.8 ENERGY CODES. April 4.,.2011'11:40:50 AM AORTEGA ---------------------------------------------------------------------------- Other Fees . . . . . . . . . ART IN PUBLIC PLACES -RES 20.00 BLDG STDS ADMIN (SB1473) 4.00 DIF COMMUNITY CENTERS -RES 74.00 DIF CIVIC CENTER - RES 995.00 ENERGY REVIEW FEE 41.57 DIF FIRE PROTECTION -RES 140.00 GRADING PLAN CHECK FEE .00 DIF LIBRARIES - RES 355.00 MULTI -SPECIES (MSHCP) FEE 533.00 DIF PARK MAINT FAC - RES 22.00 LQPERMIT Application•Number . . . . . 10-00001425. ---------------------------------------------------------------------------- Other Fees . . . . . . . . . DIF PARKS/REC .- RES 892.00 COVE PRECISE PLAN FEE 100.00 STRONG MOTION (SMI).- RES 9.94 DIF STREET MAINT FAC -RES 67.00 DIF TRANSPORTATION - RES 1930.00 Fee summary Charged Paid Credited ---------- Due ----------------- Permit Fee Total ---------- 958.71 ------ --- ---------- 134.05. .00 824.66 Plan Check Total 491.74 365.95 .00 125.79 Other Fee Total 5183.51 .00 .00 5183.51 Grand Total 6633.96 500.00 .00 6133.96 LQPERMIT P.O. Box 1504' LA QUINTA; CALIFORNIA 92247 -1 504 78-495 CALLE-fAMPIcO LA QUINTA, CALIFORNIA 92253 BUILDING & SAFETY DEPARTMENT PROPERTY OWNER'S PACKAGE ,(7 60) 777-7012 FAX (760) 777-7011 Disclosures & Forms for Owner -Builders Applying for Construction Permits WPQ.RTANT! NOTICE TO ]PROPERTY OWNER Dear Property Owner. An application for a building permit has been. submitted in your name listing yourself as the builder of the property improvements specified at We are providing you with an Owner -Builder Acknowledgment and Information Verification Form to make you aware of your responsibilities and possible risk you may incur by having this permit issued in your name as the Owner -Builder. We will not issue a building permit until you have read, initialed your understanding of each provision, signed, and returned this form to us at our official address indicated. An agent of the owner cannot execute this notice unless you, the property owner, obtain the prior approval of the permitting authority. OWNER'S ACKNOWLEDGMENT AND VERIFICATION OF II ORMAMM DIRECTIONS: Read and initial each statement below to signify you understand or verify this information, 10-16- 1. 1 understand a frequent practice of unlicensed persons is to have the property owner obtain an "Owner -Builder' building permit that erroneously implies that the property owner is providing his or her own labor and material personally. L as an Owner -Builder, may be held liable and subject to serious financial risk for any injuries sustained by an unlicensed person and his or her employees while working on my property. My homeowner's insurance may not provide coverage for those injuries. 1 am willfully acting as an Owner -Builder and am aware of.the limits of my insurance coverage for injuries to workers on my property - Cy -2- I understand building permits are not required to be signed by property owners unless they are responsible for the construction and are not hiring a licensed Contractor to assume this responsibility. C -V—'3. I understand as an "Owner -Builder" I am the responsible party of record on the permit. I understand that I may protect myself from potential financial risk by hiring a licensed Contractor and having the permit filed in his or her name instead of my own. Cil. 1 understand Contractors are required by law to be licensed and bonded in California and to list their license numbers permits and contracts. CCIL5_ I understand if I employ or otherwise engage any persons, other than California licensed Contractors, and the total vah of my construction is at least five hundred dollars ($500), including labor and materials, 1 may be considered an "employe under state and federal law. �6. l understand if l am considered an "employer" under state and federal law, I must register with the state and fede government, withhold payroll taxes, provide workers' compensation disability insurance, and contribute to uneniPloym compensation for each "employee." 1 also understand my failure to abide by these laws may subject me to serious Finan( risk. CAL 7. 1 understand under California Contractors' State License Law, an Owner -Builder who builds single-family reside► structures cannot legally build them with the intent to offer them for sale, unless all work is performed by licer subcontractors and the number of structures does not exceed four within any calendar year, or all of the work is perfor under contract with a licensed general building Contractor. U-8. 1 understand as an Owner -Builder if 1 sell the property for winch this permit is issued, 1 may be held liable for any financial or personal U' Y'a ies sustained by any subsequent owner(s) that result from any latent construction defects in the workmanship or materials. CX -9. 1 understand I may obtain more information regarding my obligations as an "employet" from the tnterral Revenue Service, the United States Small Business Administration, the California Department of Benefit Payments, and the California Division of Industrial Accidents. I also understand 1 may contact the California Contractors' State License Board (CSL,B) at I- 800-321-CSLB (2752) of www.cslb.ca.gov for more utformation about licensed contractors. GI): 10. 1 am aware of and consent to an Owner -Builder building permit applied for in my name, and understand that I am the party legally and financially responsible for proposed construction activity at the following address: C.K.. l L I agree that, as the party legally and financially responsible for this proposed construction activity, l will abide by all applicable laws and requirements that govern Owner -Builders as well as employers. U— 12. 1 agree to notify the issuer of this form immediately of any additions, deletions, or changes to any of the information I have provided on this form. Licensed contractors are regulated by laws designed to protect the public. If you contract with someone who does not have a license, the Contractors' State License Board may be unable to assist you with any financial loss you may sustain as a result of a complaint. Your only remedy against unlicensed Contractors may be in civil court It is also important for you to understand that if an unlicensed Contractor or employee of that individual or firm is injured while working on your property, you may be held liable for damages. If you obtain a permit as Owner -Builder and wish to hire Contractors; you will be responsible for verifying whether or not those Contractors are properly licensed and the status of their workers' compensation insurance coverage. Before a building permit can be issued, this form must be completed and signed by the property owner and returned to the agency responsible for issuing the permit. Note: A copy of the property owner's driver's license, form or other verification acceptable to tke agency is required to be presented when tke permit is issued to verify the Property owner's signature. Signature of property owner _4JIL— Date: Old Note: The following Authorization Form is required to be completed by the property owner only when designating an agent of the property owner to apply for a construction permit for the Owner -Builder. AUTHORIZATION OF AGENT TO ACT ON PROPERTY OWNER'S BEHALF Excluding the Notice to Property Owner, the execution of which l understand is my personal responsibility, I hereby authorize the following Person(s) to act as. my agent(s) to apply for, sign, and file the documents necessary to obtain an Owner -Builder Permit for my project. Scope of Construction Project (or Description of Work): Project Location or Address: Name of Authorized Agent: Address of Authorized Agent: Tel No I declare under penalty of perjury that l am the property owner for the address listed above and l personally filled out the at information and certify its accuracy. Note: A copy of the owner's driver's license, form notarization, or other verification acceptable to the agency is required to be presented when the permit is issued to verify the property owner's signature. Property Owner's Signature: Date: CITY OF LA QUINTA SUB -CONT I=ST JOB ADDRESS %?' ��� C' _Uj¢ PERMIT NUINIdER /D-14.26 OWNER _ „BUILDER This form shall be posted on the job with the Building Inspection Card at all times in a conspicuous place. Only persons appearing on this list or their employees are authorized to work on this job. Any changes to this list must be approved by the Building Division prior to commencement of work. Failure to comply will result in a stoppage of work and/or the voidance of building permit. For each applicable trade, all information requested below must be Completed by annlicant. "On File" iS not an grrp_ntahlp rP_SnnnRP_ Trade /..ClassiFic 0 Contractor . State.Conpa�ctW s Lrcenso.. .Workers Co. .:..7tsoxion:Insurance Ci.:Business Lac�.�se , Company Name Classification (e.g. A, B. C-8) License Number (xxxxxx) Exp. Date (xx/xx/xx) Carrier Name (e.g. State Fund, CalComp) Policy Number (Format Varies) Exp. Date (xx/xx/xx) . License Number (xxxx) Exp. Date (xx/xx/xx) EARTHWORK (C;-12:). EMC : t-xm c eAi�AfA C. -2A C`lL (000Z 11�30 )1 �QA+l(Y E WC, 112-iL SCI I CONCRETErCsa l N > Vb �- Gi2 iD3f �Z CVE('esi NahmaDLs -"1(ODO 101 D1 �2 I D 2 I iI FR14MI.NG: (.0-5) >:...:::. ::.:. . Wo w,'`o ti I N G . p - S Z,)5% O O 51 O STRUCT::S:T(=EL (C. -S1)..... MASONRY (C 29):.:...`.. �Vti1 N C(Z PLUMBING, (G=36} . M V ti L V /%(-4L- 5 84 8 3 I I S C oM �. li�fS , i t7f� +09 109-12 0 "3 0 I I 1 1J 11 f -LATH, P S.. E : ("5). DRYWALL (G-9).. OSI HVAC (C=20), - ' © A <✓ (� ELECTRICAL. (C:=10) ROORNG (C-39) N fo`i"D N \ N C - 51 l`� �lJ t� Z� Oa S(o O '1 SHM.T.'META1: . F O:ORJNG (C-.1:51: i -Q C --R .GLAZ)N:G (C-17) INSfJ1LhTIO.N. EG:=2:1 Q w (V SEWAGE I�tSP'i�2? PAINTING (C=33). CERAMIC TILE:(C-54). 0 VJ N E-P� CABINETS (C-6). FENCING '(C,1,3) LANDSCAPING. (C-27) POOL (C-53) . . Ib_ IL}1 Building 11.1 it lww JA- Tjhf 4 4 a" P.O. BOX 1504 APPLICATION ONLY 78-495 CALLE TAMPICO VAL LA QUINTA, CALIFORNIA 92253 uwner Trityl _ ` f A / / I mailing V 4� O A f t , Address �n1 �( (�[.,,1� Vim, q(A) r4liH Zi W2 Contractor Address Zip State Lia city & Classif. Lic. # Arch., Engr., Designer YdeC �UK Z11 Lict# ' LICENSED CONTRACTOR'S DECLARATION 1 hereby affirm that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, and my license is in full force and effect. SIGNATURE DATE OWNER -BUILDER DECLARATION I hereby affirm that I am exempt from the Contractor's License Law for the following reason: (Sec. 7031.5, Business and Professions Code: Any city or county which requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor's License Law, Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, or that he is exempt therefrom, and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500). O I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. (Sec. 7044, Business and Profes- sions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or Im- provement is sold within one year of completion, the owner -builder will have the burden of proving that he did not build or improve for the purpose of sale). D I, as owner of the property, am exclusively contracting with licensed contractors to construct the project. (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who contracts for such projects with a contractor(s) licensed pursuant to the Contractor's License Law) ❑ 1 am exempt under Sec. B. & P.C. for this reason Date Owner WORKER'S COMPENSATION DECLARATION I hereby affirm that I have a certificate of consent to self -insure, or a certificate of Worker's Compensation Insurance, or a certified copy thereof. (Sec. 3800, Labor Code.) Policy No. Company ❑ Copy is filed with the city. ❑ Certified copy is hereby furnished. CERTIFICATE OF EXEMPTION FROM WORKERS' COMPENSATION INSURANCE (This section need not be completed it the permit is for one hundred dollars ($100) valuation or less). I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to Workers' Compensation Laws of California. Date Owner NOTICE TO APPLICANT.. If, after making this Certificate of Exemption you should become subject to the Workers' Compensation Provisions of the Labor Code, you must forthwith comply with such provisions or this permit shall be deemed revoked. CONSTRUCTION LENDING AGENCY I hereby affirm that there is a construction lending agency for the performance of the work for which this permit is issued. (Sec. 3097, Civil Code.) Lender's Name Lender's Address This is a building permit when properly filled out, signed and validated, and is subject to expiration if work thereunder is suspended for 180 days. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter the above-mentioned property for inspection purposes. Signature of applicant Date Mailing Address City, State, Zip WHITE = BUILDING DEPARTMENT BUILDING: TYPE CO ST. OCC. GRP. Pl- A.P Number�� Legal Description C Project Description If If Sq. Ft. Size New'N No. j No. Dw. Stories / Units Add ❑ Alte'r ❑ Repair ❑ Demolition ❑ Estimated Valuation PERMIT AMOUNT Plan Chk. Dep. Plan Chk. Bal. Const. Mech. Electrical Plumbing S.M.I. Grading Driveway Enc. Infrastructure Inj 2610r TOTAL REMARKS • ZONE: BY: Minimum Setback Distances: Front Setback from Center Rear Setback from Rear Prop. Line Side Street Setback from Center Line Side Setback from Property Li FINAL DATE INSPECTOR Issued by: Validated by: Validation: Date YELLOW = APPLICANT PINK = FINANCE Date 4/8/11 No. 30962 Owner Christian Knall Address City Zip . Tract # Type Single Family Residence CERTIFICATE OF COMPLIANCE Desert Sands Unified School District 47950 Dune Palms Road La Quinta, CA 92253 (760) 771-8515 APN # Jurisdiction Permit # No. of Units o Q BERMUDA DUNES C' RANCHO MIRAGE CJ �. INDIAN WELLS PALM DESERT ,y LA QUINTA 1Q1 N0Oy� 8 774-115-015 La Quinta 1 Lot # No. Street S.F. Lot # No. Street S.F. Unit 1 77490 Calle Arroba 1514 Unit 6 Unit 2 Unit 7 Unit 3 Unit 8 Unit 4 Unit 9 Unit 5 Unit 10 Comments At the present time, the Desert Sands Unified School'District does not collect fees on garages/carports, covered patios/walkways, residential additions under 500 square feet, detached accessory structures (spaces that do not contain facilities for living, sleeping, cooking, eating or sanitation) or replacement mobile homes. It has been determined that the above-named owner is exempt from paying school fees at this time due to the following reason: EXEMPTION NOT APPLICABLE This certifies that school facility fees imposed pursuant to Education Code Section 17620 and Government Code 65995 Et Seq. in the amount of $2.97 X 1,514 S.F. or $4,496.58 have been paid for the property listed above and that building permits and/or Certificates of Occupancy for this square footage in this proposed project may now be issued. Fees Paid By CC/Bank of America - Christian Knall Check No. 432307996 Name on the check Telephone 310-703-4849 Funding Residential BY Dr. Sharon P. McGehee Superintendent Fee collected /exemp d by Sh roGil r y Payment Recd ; :!$0.00 : - $4,496.58 : �Over/Under' Fti . Signature " NOTICE: Pursuari4 to Government Code Section 66020(d)(1), this VAs�ve to notify you that the 90 -day approval period in which you may protest the fees or other payment identified above will begin to run from the date on which the building or installation permit for this project is issued, or from the date on which those amounts are paid to the District(s) or to another public entity authorized to collect them on the District('s) behalf, whichever is earlier. NOTICE: This Document NOT VALID without embossed seal Embossed Original - Building Department Applicant Copy - Applicant/Receipt Copy - Accounting R Tjhf 4 4 a" P.O. BOX 1504 78-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 To: Greg Butler, Building & Safety Manager From: Les Johnson, Director -PDD BUILDING & SAFETY DEPARTMENT (760) 777-7012 FAX (760) 777-7011 To PD: 04-04-11 Due Date: ASAP Permit #: 10-1425 Status: 1 ST REVIEW Building Plans Approval (This is an approval to issue a Building Permit) The Planning Department has reviewed the Building Plans for the following project: Description: COVE CHECK/ -V Address or General Location: 77-490 CALLE ARROBA Applicant Contact: STEVEN NIETO 760-564-4707 The Planning Development Department finds that: ❑ ...these Building Plans do not require Planning Department approval. IJP ...these Building Plans are approved by the Planning Department. ❑ ...these Building Plans require corrections. Please forward a copy of the attached corrections to the applicant. When the corrections are made please return them to the Planning Department for review. ll Les Johnson. Director -PD Date APR 5' Clay of La WOO PlcnnFng b9pG��t r : JOVEN ENGINEERING S t r u c t u r a .I E n g i n e e r i n g r r . MT772 P.O. BOX 5098 La Quinta, CA 92248-5098 (760) 408-6441 March 11, 2011 City of La Quinta Building & Safety Department 78-495 Calle Tampico La Quinta, CA 92253-1504 Attn. Department of Building and Safety Ref: Knall Residence 77-490 Calle Arroba La Quinta, CA Plan Check No. 10-1425 Subject: Roof Truss Calcs Dear Sirs, Job No. 10-582 We have been provided with Truss Calculations package provided by Spates Fabricators to be used for referenced project. We have reviewed Truss layout and Calculations and find them to be in general agreement with the design intent for this project. If you have further questions, please feel free to call. Sincerely, loven 7'. r J1 seph R. Venuti, C.E. 41210 C JOVEN JOBS yilfl'i: 1 RHSSR-I APD RECORDING REQUESTED BY: Ticor Title Co. AND WHEN RECORDED MAIL TO: A Christian Knall 4224 La Salle Avenue Culver City, CA 90232 TICOR TITLE REDLANDS -77q.- Title Order No.: 5273481 M -- DOC # 2010®0142774 03/30/2010 08:00A Fee:15.00 Page 1 of 1 Doc T Tax Paid Recorded in Official Records County of Riverside Larry W. Ward Assessor, County Clerk & Recorder IIIIII IIIIIII III IIIII IIII IIIIIIII VIII III VIII IIII IIII GRANT DEED THE UNDERSIGNED GRANTOR(S) DECLARE(S) DOCUMENTARY TRANSFER TAX is $55.00 [X] computed on full value of property conveyed, or [ ] computed on full value less value of liens or encumbrances remaining at time of sale. [X] City of La Quinta AND FOR A VALUABLE CONSIDERATION, receipt of which is hereby acknowledged, Elizabeth Vasquez, a Single Woman hereby GRANT(s) to: IOSAF Christian/Knall, a Single Man the real property in the City of La Quinta, County of Riverside, State of California, described as: Lot 12, Block 188. Santa Carmelita at Vale La Quinta, Unit 19, as per map recorded in Book 19, Page 34 of Maps, in the Office of the County Recorder of said County. Also Known as: Vacant Lot - APN 774-115-012-2, La Quinta, CA 92253 - DATED March 12, 2010 STATE OF C FORNIA ' COUNTY OFA, On before me, 11 t " 1h ,e- A Notary Public in and for said State persona ElizabV6-5er6ez who proved to me on the basis of satisfactory evidence to be VII CKIE K. DONATI the person(s) whose name(s) is/are subscribed to the within '' ' Commission # 1715534 instrument and acknowledged to me that he/she/they < <�� $, Notary Public - California z executed the same in his/her/their authorized capacity(ies), Z Riverside County and that by his/her/their signature(s) on the instrument the My Comm. Expires Feb 7,2011 person(s), or the entity upon behalf of which the person(s) acted, executed the instrument. I certify under PENALTY OF PERJURY under the laws of the State of California that the foregoing paragraph ' and correct. WITNESS my hand 9nd official seal. _ Signature - (Seal) MAIL TAX ST_TEMENT RTYSH0WU ARTY SHOWN, MAIL AS DIRECTED ABOVE: U PAGE SIZE DA MISC LONG RFD COPY ffMl L 465 426 CO NCOR SMF HG / EXAM V" fUNI T: CTY GRANT DEED THE UNDERSIGNED GRANTOR(S) DECLARE(S) DOCUMENTARY TRANSFER TAX is $55.00 [X] computed on full value of property conveyed, or [ ] computed on full value less value of liens or encumbrances remaining at time of sale. [X] City of La Quinta AND FOR A VALUABLE CONSIDERATION, receipt of which is hereby acknowledged, Elizabeth Vasquez, a Single Woman hereby GRANT(s) to: IOSAF Christian/Knall, a Single Man the real property in the City of La Quinta, County of Riverside, State of California, described as: Lot 12, Block 188. Santa Carmelita at Vale La Quinta, Unit 19, as per map recorded in Book 19, Page 34 of Maps, in the Office of the County Recorder of said County. Also Known as: Vacant Lot - APN 774-115-012-2, La Quinta, CA 92253 - DATED March 12, 2010 STATE OF C FORNIA ' COUNTY OFA, On before me, 11 t " 1h ,e- A Notary Public in and for said State persona ElizabV6-5er6ez who proved to me on the basis of satisfactory evidence to be VII CKIE K. DONATI the person(s) whose name(s) is/are subscribed to the within '' ' Commission # 1715534 instrument and acknowledged to me that he/she/they < <�� $, Notary Public - California z executed the same in his/her/their authorized capacity(ies), Z Riverside County and that by his/her/their signature(s) on the instrument the My Comm. Expires Feb 7,2011 person(s), or the entity upon behalf of which the person(s) acted, executed the instrument. I certify under PENALTY OF PERJURY under the laws of the State of California that the foregoing paragraph ' and correct. WITNESS my hand 9nd official seal. _ Signature - (Seal) MAIL TAX ST_TEMENT RTYSH0WU ARTY SHOWN, MAIL AS DIRECTED ABOVE: • is • .,,..,o BUILDING ENERGY ANALYSIS REPORT. . , I _ 1 , PROJECT: Knall Residence 77-490 Calle Arroba La Quinta, CA 92253 Project Designer: South West Concepts 78=115 Calle Estado La Quinta, CA 92253 (760) 564-4707 Report Prepared by: Tim Scott Scott Design and Title 24, Inc, 77-085 Michigan Drive Palm Desert, Ca 92211 (760) 200-4780 Job Number: Io. 14% Orr" CITY OF LA QUINTA BUILDING & SAFETY DEPT. APPROVED FOR CONSTRUCTION DATE4 4 �� BY&= Date: L', MAR 1 d 2011 1 J 1 3/2/2011 The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2008 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC — www.energysoft.com. Enemy Pro 5.1 by EnergySoft User Number: 6712 RunCode: 2011-03-02710:00:06 ID: • • PERFORMANCE CERTIFICATE: Residential Part 1 of 5 CF -1 R Project Name Knall Residence Building Type m Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 3/212011 Project Address 77-490 Calle Arroba La Quinta California Energy Climate Zone CA Climate Zone 15 Total Cond. Floor Area 1,514 Addition n/a # of Stories 1 FIELD INSPECTION ENERGY CHECKLIST ❑ Yes ❑ No HERS Measures -- If Yes, A CF -4R must be provided per Part 2 of 5 of this form. ❑ Yes ❑ No Special Features -- If Yes, see Part 2 of 5 of this form for details. INSULATION Construction Type Area Special Cavity ( Features see Part 2 of 5 Status Roof Wood Framed Attic R-38 1,514 Radiant Barrier Cool Roof New Wall Wood Framed R-13 1,326 Ext --R-5.0 New Door Opaque Door None 20 New Slab Unheated Slab -on -Grade None 1,514 Perim = 168' New FENESTRATION U- Exterior Orientation Area(ft) Factor SHGC Overhang Sidefins Shades Status Right (N) 12.0 0.450 0.39 4.0 none Bug Screen New Right (N) 4.0 0.470 0.39 4.0 none Bug Screen New Right (N) 25.0 0.470 0.39 6.0 none Bug Screen New Right (N) 29.0 0.470 0.39 none none Bug Screen New Front (E) 28.0 0.470 0.39 none none Bug Screen New Left (S) 53.3 0.510 0.39 none none Bug Screen New Left (S) 51.0 0.450 0.39 none none Bug Screen New Left (S) 20.0 0.510 0.39 4.0 none Bug Screen New Left (S) 6.0 0.470 0.39 4.0 none Bug Screen New Left (SKM 17.5 0.470 0.39 none none Bug Screen New Rear (KM 33.3 0.510 0.39 4.0 none Bug Screen New HVAC SYSTEMS Ot . Heating Min. Eff Cooling Min. Eff Thermostat Status 1 Central Fumace 80% AFUE Split Air Conditioner 14.0 SEER Setback New HVAC DISTRIBUTION Location Heating Duct Cooling Duct Location R -Value Status A/C 1 Ducted Ducted Attic, Ceiling Ins, vented 8.0 New WATER HEATING Ot . Type Gallons Min. Eff Distribution Status 1 Small Gas 50 0.62 All Pipes Ins New EnergyPro 5.1 by EnergySoft User Number., 6712 RunCode: 2011-03-02T10:00.06 ID: Page 3 of 18 • • PERFORMANCE CERTIFICATE: Residential Part1 of 5 CF -1 R Project Name Knall Residence Building Type m Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 3/2/2011 Project Address 77-490 Calle An-oba La Quinta California Energy Climate Zone CA Climate Zone 15 Total Cond. Floor Area 1,514 Addition n/a # of Stories 1 FIELD INSPECTION ENERGY CHECKLIST ❑ Yes ❑ No HERS Measures -- If Yes, A CF -413 must be provided per Part 2 of 5 of this form. ❑ Yes ❑ No Special Features -- If Yes, see Part 2 of 5 of this form for details. INSULATION Area Special Construction Type Cavity (ft) Features see Part 2 of 6 Status FENESTRATION U- Exterior Orientation Area Factor SHGC Overhang Sidefins Shades Status Rear (K9 10.0 0.450 0.39 4.0 none Bug Screen New Rear (WJ 25.0 0.470 0.39 none none Bug Screen New Rear (Kq 10.0 0.450 0.39 none none Bug Screen New HVAC SYSTEMS Ot . Heating Min. Eff Cooling Min. Eff Thermostat Status HVAC DISTRIBUTION Duct Location Heating Cooling Duct Location R -Value Status WATER HEATING Ot . Type Gallons Min. Eff Distribution Status EneTyPro 5.1 by EnergySoft User Number. 6712 Run Code: 2011-03-02T10:00:06 ID: n--- 4 of 18 I • • PERFORMANCE CERTIFICATE: Residential (Part 2 of 5) CF -1 R Project Name Knall Residence Building Type m Single Family ❑ Addition Alone 1 ❑ Multi Family ❑ Existing+ Addition/Alteration I Date 3/2/2011 SPECIAL FEATURES INSPECTION CHECKLIST The enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted. The Roof R-38 Roof Attic Reflectance = 0. 65, Emittance = 0.75 shall be rated and labeled by the Cool Roof Rating Council in accordance with Section 10-113 of the standards. The Roof R-38 Roof Attic includes credit for a Radiant Barrier that is Continuous meeting eligibility and installation criteria as specified in Residential Appendix RA4.2.2. HERS REQUIRED VERIFICATION Items in this section require field testing and/or verification by a certified HERS Rater. The inspector must receive a completed CF -411 form for each of the measures listed below for final to be given. The Cooling System Carrier 24ACB460158DLX110 includes credit for a 12.0 EER Condenser. A certified HERS rater must field verify the installation of the correct Condenser. The HVAC System A/C 1 incorporates HERS Verified Refrigerant Charge or a Charge Indicator Display. The HVAC System A/C 1 incorporates HERS verified Duct Leakage. HERS field verification and diagnostic testing is required to verify that duct leakage meets the specified criteria. EnergyPro 5.1 by Ene Soft User Number..- 6712 RunCode: 2011-03-02710:00:06 ID: Page 5 of 18 C • • PERFORMANCE CERTIFICATE: Residential (Part 3 of 5) CF -1 R Project Name Building Type m Single Family ❑ Addition Alone Date Knall Residence 1 ❑ Multi Family ❑ Existing+ Addition/Alteration 3/212011 ANNUAL ENERGY USE SUMMARY Standard Proposed Margin TDV kBtu/ft2- r Space Heating 3.19 3.57 -0.38 Space Cooling 59.50 55.04 4.46 Fans 12.03 15.66 -3.63 Domestic Hot Water 19.27 17.37 1.90 Pumps 0.00 0.00 0.00 Totals 93.99 91.64 2.35 Percent Better Than Standard: 2.5% BUILDING COMPLIES - HERS VERIFICATION REQUIRED Fenestration Building Front Orientation: (E) 90 deg Ext. Walls/Roof Wall Area Area Number of Dwelling Units: 1.00 (E) 350 28 Fuel Available at Site: Natural Gas (S) 500 148 Raised Floor Area: 0 (►M 330 78 Slab on Grade Area: 1,514 (N) 490 70 Average Ceiling Height: 10.0 Roof 1,514 0 Fenestration Average U -Factor: 0.48 TOTAL: 324 Average SHGC: 0.39 Fenestration/CFA Ratio: 21.4% REMARKS STATEMENT OF COMPLIANCE This certificate of compliance lists the building features and specifications needed to comply with Title 24, Parts 1 the Administrative Regulations and Part 6 the Efficiency Standards of the California Code of Regulations. The documentation author hereby certifies that the documentation is accurate and complete. Documentation Author Company Scott Design and Title 24, Inc,4 322011 Address 77-085 Michigan Drive Name Tim Scott City/State/ZipCity/State/Zip Palm Desert Ca 92211 Phone (760) 200-4780 Signed Date The individual with overall design responsibility hereby certifies that the proposed building design represented in this set of construction documents is consistent with the other compliance forms and worksheets, with the specifications, and with any other calculations submitted with this permit application, and recognizes that compliance using duct design, duct sealing, verification of refrigerant charge, insulation installation quality, and building envelope sealing require installer testing and certification and field verification by an approved HERS rater. Designer or Owner (per Business & Professions Code) Company South West Concepts Address 78-115 Calle Estado Name Steve Nieto City/State/Zip La Quinta, CA 92253 Phone (760) 564-4707 Signed License # Date EnemvPro 5.1 by EnemySoft User Number: 6712 Run Code: 2011-03-02T10:00:06 ID: Page 6 of 18 Ah • CERTIFICATE OF COMPLIANCE: Residential (Part 4 of 5) CF -1 R Project Name Knag Residence Building Type m Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 3/2/2011 OPAQUE SURFACE DETAILS Surface Type Area U- Insulation Factor Cavity Exterior Frame Interior Frame Azm Joint Appendix Tilt Status 4 Location/Comments Roof 1,514 0.026 R-38 0 0 New 4.2.1-A9 Entire Residence Wall 420 0.068 R-13 5.0 None 0 90 New 4.3.1-A3 Entire Residence Wall 302 0.068 R-13 5.0 None 90 90 New 4.3.1-A3 Entire Residence Door 20 1.450 None 90 90 New 4.5.1-A1 Entire Residence Wall 3301 0.068 R-13 5.0 None 180 90 New 4.3.1-A3 Entire Residence Wall 231 0.068 R-13 5.0 None 225 90 New 4.3.1-A3 Entire Residence Wall 2521 0.068 R-13 5.0 None 270 90 New 4.3.1-A3 Entire Residence Slab 1,093 0.730 None 0 180 New 4.4.7-A1 Entire Residence Slab 421 0.730 None 0 180 New 4.4.7-A1 Entire Residence FENESTRATION SURFACE DETAILS ID Type Area U -Factor SHGC Azm Status Glazing Type Location/Comments 1 Window 12.0 0.450 NFRC 0.39 NFRC 0 New Double Tinted-Oper Entire Residence 2 Window 4.0 0.470 NFRC 0.39 NFRC 0 New Double Tinted Entire Residence 3 Window 25.0 0.470 NFRC 0.39 NFRC 0 New Double Tinted Entire Residence 4 Window 4.0 0.470 NFRC 0.39 NFRC 0 New Double Tinted Entire Residence 5 Window 25.0 0.470 NFRC 0.39 NFRC 0 New Double Tinted Entire Residence 6 Window 20.0 0.470 NFRC 0.39 NFRC 90 New Double Tinted Entire Residence 7 Window 8.0 0.470 NFRC 0.39 NFRC 90 New Double Tinted Entire Residence 8 Window 33.3 0.510 NFRC 0.39 NFRC 180 New Double Tinted -Doors Entire Residence 9 Window 10.0 0.450 NFRC 0.39 NFRC 180 New Double Tinted -Window Entire Residence 10 Window 20.0 0.510 NFRC 0.39 NFRC 180 New Double Tinted -Doors Entire Residence 11 Window 6.0 0.450 NFRC 0.39 NFRC 180KNewDouble le Tinted -Window Entire Residence 12 Window 25.0 0.450 NFRC 0.39 NFRC 180le Tinted -Window Entire Residence 13 Window 10.0 0.450 NFRC 0.39 NFRC 180 Tinted -Window Entire Residence 14 Window 20.0 0.510 NFRC 0.39 NFRC 180le Tinted -Doors Entire Residence 15 Window 6.0 0.470 NFRC 0.39 NFRC 180le Tinted Entire Residence 16 Window 10.5 0.470 NFRC 0.39 NFRC 225le Tinted Entire Residence (1) U -Factor Type: 116-A = Default Table from Standards, NFRC = Labeled Value 2 SHGC Type: 116-13 = Default Table from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAILS ID Exterior Shade Type SHGC Window L!jqL Wd Ove hang Left Fin Len HqA LExt REM Dist Len Right Fin H t Dist Len H t 1 Bug Screen 0.76 6.7 3.0 4.0 0.1 4.0 4.0 2 Bug Screen 0.76 2.0 3.0 4.0 0.1 4.0 4.0 3 Bug Screen 0.76 8.0 3.0 6.0 0.1 6.0 6.0 4 Bug Screen 0.76 5 Bug Screen 0.76 6 Bug Screen 0.76 7 Bug Screen 0.76 8 Bug Screen 0.76 9 Bug Screen 0.76 10 Bug Screen 0.76 11 Bua Screen 0.76 12 Bug Screen 0.76 13 Bug Screen 0.76 14 Bug Screen 0.76 6.7 6.0 4.0 0.1 4.0 4.0 15 Bug Screen 1 0.76 2.0 3.0 4.0 0.1 4.0 4.0 16 Bug Screen 0.76 EnergyPro 5.1 by EnergySoft User Number: 6712 RunCode: 2011-03-02T10:00:06 ID: Page 7 of 18 • • CERTIFICATE OF COMPLIANCE: Residential (Part 4 of 5) CF -1 R Project Name Knall Residence Building Type m Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 3/2/2011 OPAQUE SURFACE DETAILS Surface U- Type Area Factor Insulation Joint Appendix Cavi Exterior Frame Interior Frame Azm Tilt Status 4 Location/Comments FENESTRATION SURFACE DETAILS ID Type Area U -Factor SHGC Azm Status Glazing Type Location/Comments 17 Window 7.0 0.470 NFRC 0.39 NFRC 225 New Double Tinted Entire Residence 18 Window 33.3 0.510 NFRC 0.39 NFRC 270 New Double Tinted -Doors Entire Residence 19 Window 10.0 0.450 NFRC 0.39 NFRC 270 New Double Tinted -Window Entire Residence 20 Window 25.0 0.470 NFRC 0.39 NFRC 270 New Double Tinted Entire Residence 21 Window 1 10.0 0.450 NFRC 0.39 NFRC 270 New Double Tinted -Window Entire Residence (1) U -Factor Type: 2 SHGC Type: 116-A = Default Table from Standards, NFRC = Labeled Value 116-13 = Default Table from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAILS ID Exterior Shade Type Window SHGC H t Wd Ove hang Left Fin Right Fin Len HqA LExt RExt Dist Len H t Dist Len H t 17 Bug Screen 0.76 18 Bug Screen 0.76 6.7 5.0 4.0 0.1 4.0 4.0 19 Bug Screen 0.76 2.0 5.0 4.0 0.1 4.0 4.0 20 Bug Screen 0.76 21 Bug Screen 0.76 EnergyPro 5.1 by EnergySoft User Number: 6712 RunCode: 2011-03-02T10:00:06 ID: Page 8 of 18 C] • • CERTIFICATE OF COMPLIANCE: Residential Part 5 of 5) CF -1 R Project Name Knall Residence Building Type ❑ Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 3/2/2011 BUILDING ZONE INFORMATION System Name Zone Name Floor Area New Existinq Altered Removed Volume Year Built A/C 1 Entire Residence 1,514 15,140 Totals 1,514 0 01 0 HVAC SYSTEMS System Name Qty. Heating Type Min. Eff. Cooling Type Min. Eff. Thermostat Type Status A/C 1 1 Central Fumace 80% AFUE Split Air Conditioner 14.0 SEER Setback New HVAC DISTRIBUTION System Name Heating Duct Ducts Cooling Duct Location R -Value Tested? Status A/C 1 Ducted Ducted Attic, Ceiling Ins, vented 8.0 m New 13 WATER HEATING SYSTEMS S stem Name Qty. Type Distribution Rated Input Btuh Tank Cap. al Energy Factor or RE Standby Loss or Pilot Ext. Tank Insul. R- Value Status A.O. Smith #PGCG-50-22 1 JSmallGas All Pipes Ins 40,000 50 0.62 n/a n/a New MULTI -FAMILY WATER HEATING DETAILS HYDRONIC HEATING SYSTEM PIPING Control Hot Water Piping Length ft � 0 i� v a — System Name Pipe Length Pipe Diameter Insul. Thick. 7Qty. HP Plenum Outside Buried 13 EnergyPro 5.1 by EnergySoft User Number: 6712 RunCode: 2011-03-02710:00:06 ID: Page 9 of 18 4 MANDATORY MEASURES SUMMARY: Residential Pae 1 of 3 MF -1 R Project Name nail Residence Date 3/2/2019 NOTE: Low-rise residential buildings subject to the Standards must comply with all applicable mandatory measures listed, regardless of the compliance approach used. More stringent energy measures listed on the Certificate of Compliance (CF -1 R, CF -1 R -ADD, or CF - 1 R -ALT Form) shall supersede the items marked with an asterisk (•) below. This Mandatory Measures Summary shall be incorporated into the permit documents, and the applicable features shall be considered by all parties as minimum component performance specifications whether they are shown elsewhere in the documents or in this summary. Submit all applicable sections of the MF -1 R Form with plans. Building Envelope Measures: 116(a)l: Doors and windows between conditioned and unconditioned spaces are manufactured to limit air leakage. §116(a)4: Fenestration products (except field -fabricated windows) have a label listing the certified U -Factor, certified Solar Heat Gain Coefficient SHGC and infiltration that meets the requirements of 10-111 (a). 117: Exterior doors and windows are weather-stripped; all joints and penetrations are caulked and sealed. 118(a): Insulationspecified or installed meets Standards for Insulating Material. Indicate type and include on CF -613 Form. §118(1): The thermal emittance and solar reflectance values of the cool roofing material meets the requirements of §118(1) when the installation of a Cool Roof is specified on the CF -1 R Form. *§1 50 a : Minimum R-19 insulation in wood -frame ceiling orequivalent U -factor. 150(b): Loose fill insulation shall conform with manufacturer's installed design labeled R -Value. *§1 50 c : Minimum R-13 insulation in wood -frame wall orequivalent U -factor. *§1 50 d : Minimum R-13 insulation in raised wood -frame floor orequivalent U -factor. 150(f): Air retarding wrap is tested labeled, and installed according to ASTM E1677-95 2000 when specified on the CF -1 R Form. 150 : Mandatory Vapor barrier installed in Climate Zones 14 or 16. §150(1): Water absorption rate for slab edge insulation material alone without facings is no greater than 0.3%; water vapor permeance rate is no greater than 2.0perm/inch and shall be protected from physical damage and UV light deterioration. Fireplaces, Decorative Gas Appliances and Gas Log Measures: 150 (e)IA: Masonry or factory -built fireplaces have a closable metal or glass door covering the entire opening of the firebox. §150(e)1 B: Masonry or factory -built fireplaces have a combustion outside air intake, which is at least six square inches in area and is eq ui ed with a with a readily accessible operable, and tight -fitting damper and or a combustion -air control device. §150(e)2: Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the outside of the building, are prohibited. Space Conditioning, Water Heating and Plumbing System Measures: §110-§113: HVAC equipment, water heaters, showerheads, faucets and all other regulated appliances are certified by the Energy Commission. §113(c)5: Water heating recirculation loops serving multiple dwelling units and High -Rise residential occupancies meet the air release valve, backflow prevention, pump isolation valve, and recirculation loop connection requirements of §113(c)5. §115: Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces, household cooking appliances (appliances with an electrical supply voltage connection with pilot lights that consume less than 150 Btu/hr are exempt), and pool and spa heaters. 150(h): Heating and/or cooling loads are calculated in accordance with ASHRAE, SMACNA or ACCA. 150(i): Heating systems are equipped with thermostats that meet the setback requirements of Section 112(c). §1500)1A: Storage gas water heaters rated with an Energy Factor no greater than the federal minimal standard are externally wrapped with insulation having an installed thermal resistance of R-12 or greater. §1500)1 B: Unfired storage tanks, such as storage tanks or backup tanks for solar water -heating system, or other indirect hot water tanks have R-12 external insulation or R-16 internal insulation where the internal insulation R -value is indicated on the exterior of the tank. §1500)2: First 5 feet of hot and cold water pipes closest to water heater tank, non -recirculating systems, and entire length of recirculatinq sections of hot water pipes are insulated per Standards Table 150-13. §1500)2: Cooling system piping (suction, chilled water, or brine lines),and piping insulated between heating source and indirect hot water tank shall be insulated to Table 150-B and Equation 150-A. §1500)2: Pipe insulation for steam hydronic heating systems or hot water systems >15 psi, meets the requirements of Standards Table 123-A. 150(j)3A: Insulation is protected from damage, including that due to sunlight, moisture equipment maintenance and wind. §1500)3A: Insulation for chilled water piping and refrigerant suction lines includes a vapor retardant or is enclosed entirely in conditioned space. 150 ' 4: Solar water -heating systems and/or collectors are certified by the Solar Rating and Certification Corporation. EnergyPro 5.1 by EnergySoft User Number: 6712 RunCode: 2011-03-02710:00:06 ID: Page 10 of 18 MANDATORY MEASURES SUMMARY: Residential (Page 2 of 3 MF -1 R Project Name Date nall Residence 3/2/2011 §150(m)1: All air -distribution system ducts and plenums installed, are sealed and insulated to meet the requirements of CMC Sections 601, 602, 603, 604, 605 and Standard 6-5; supply -air and return -air ducts and plenums are insulated to a minimum installed level of R- 4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct -closure system that meets the applicable requirements of UL 181, UL 181 A, or UL 181 B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings reater than 1/4 inch the combination of mastic and either mesh or tape shall be used §150(m)1: Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area of the ducts. §150(m)2D: Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such tape is used in combination with mastic and draw bands. 150(m)7: Exhaust fans stems have back draft or automatic dampers. §150(m)8: Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated dampers. §150(m)9: Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that can cause degradation of the material. 150 m 10: Flexible ducts cannot have porous inner cores. §150(o): All dwelling units shall meet the requirements of ANSI/ASHRAE Standard 62.2-2007 Ventilation and Acceptable Indoor Air Quality in Low -Rise Residential Buildings. Window operation is not a permissible method of providing the Whole Building Ventilation required in Section 4 of that Standard. Pool and Spa Heating Systems and Equipment Measures: §114(a): Any pool or spa heating system shall be certified to have: a thermal efficiency that complies with the Appliance Efficiency Regulations; an on-off switch mounted outside of the heater; a permanent weatherproof plate or card with operating instructions; and shall not use electric resistance heating ora pilot light. §114(b)1: Any pool or spa heating equipment shall be installed with at least 36" of pipe between filter and heater, or dedicated suction and return lines, or built-up connections for future solar heating. 114(b)2: Outdoor pools ors as that have a heat pump or gas heater shall have a cover. §114(b)3: Pools shall have directional inlets that adequately mix the pool water, and a time switch that will allow all pumps to be set or programmed to run only during off-peak electric demand periods. 150 : Residential pool systems orequipment meet the pump sizing, flow rate, piping, filters, and valve requirements of §150 . Residential Lighting Measures: §150(k)1: High efficacy luminaires or LED Light Engine with Integral Heat Sink has an efficacy that is no lower than the efficacies contained in Table 150-C and is not a low efficacy luminaire asspecified by §150(k)2. 150(k)3: The wattage of permanently installed luminaires shall be determined asspecified by §130(d). §150(k)4: Ballasts for fluorescent lamps rated 13 Watts or greater shall be electronic and shall have an output frequency no less than 20 kHz. §150(k)5: Permanently installed night lights and night lights integral to a permanently installed luminaire or exhaust fan shall contain only high efficacy lamps meeting the minimum efficacies contained in Table 150-C and shall not contain a line -voltage socket or line - voltage lamp holder; OR shall be rated to consume no more than five watts of power as determined by §130(d), and shall not contain a medium screw -base socket. 150(k)6: Lighting integral to exhaust fans, in rooms other than kitchens, shall meet the applicable requirements of §150(k). 150(k)7: All switching devices and controls shall meet the requirements of §150(k)7. §150(k)8: A minimum of 50 percent of the total rated wattage of permanently installed lighting in kitchens shall be high efficacy. EXCEPTION: Up to 50 watts for dwelling units less than or equal to 2,500 ft2 or 100 watts for dwelling units larger than 2,500 ft2 may be exempt from the 50% high efficacy requirement when: all low efficacy luminaires in the kitchen are controlled by a manual on occupant sensor, dimmer, energy management system (EMCS), or a multi -scene programmable control system; and all permanently installed luminaries in garages, laundry rooms, closets greater than 70 square feet, and utility rooms are high efficacy and controlled by a manual -on occupant sensor. §150(k)9: Permanently installed lighting that is internal to cabinets shall use no more than 20 watts of power per linear foot of illuminated cabinet. EnergyPro 5.1 by EnergySoR User Number: 6712 RunCode: 2011-03-02710:00:06 ID: Page 11 of 18 • F, 4 MANDATORY MEASURES SUMMARY: Residential (Page 3 of 3 MF -1 R Project Name Date Knall Residence 1 3/2/2011 §150(k)l0: Permanently installed luminaires in bathrooms, attached and detached garages, laundry rooms, closets and utility rooms shall be high efficacy. EXCEPTION 1: Permanently installed low efficacy luminaires shall be allowed provided that they are controlled by a manual -on occupant sensor certified to comply with the applicable requirements of §119. EXCEPTION 2: Permanently installed low efficacy luminaires in closets less than 70 square feet are not required to be controlled by a manual -on occupancy sensor. §150(k)l 1: Permanently installed luminaires located in rooms or areas other than in kitchens, bathrooms, garages, laundry rooms, closets, and utility rooms shall be high efficacy luimnaires. EXCEPTION 1: Permanently installed low efficacy luminaires shall be allowed provided they are controlled by either a dimmer switch that complies with the applicable requirements of §119, or by a manual - on occupant sensor that complies with the applicable requirements of §119. EXCEPTION 2: Lighting in detached storage building less than 1000 square feet located on a residential site is not required to comply with §150 k 11. §150(k)l2: Luminaires recessed into insulated ceilings shall be listed for zero clearance insulation contact (IC) by Underwriters Laboratories or other nationally recognized testing/rating laboratory; and have a label that certifies the lumiunaire is airtight with air leakage less then 2.0 CFM at 75 Pascals when tested in accordance with ASTM E283; and be sealed with a gasket or caulk between the luminaire housing and ceiling. §150(k)13: Luminaires providing outdoor lighting, including lighting for private patios in low-rise residential buildings with four or more dwelling units, entrances, balconies, and porches, which are permanently mounted to a residential building or to other buildings on the same lot shall be high efficacy. EXCEPTION 1: Permanently installed outdoor low efficacy luminaires shall be allowed provided that they are controlled by a manual on/off switch, a motion sensor not having an override or bypass switch that disables the motion sensor, and one of the following controls: a photocontrol not having an override or bypass switch that disables the photocontrol; OR an astronomical time clock not having an override or bypass switch that disables the astronomical time clock; OR an energy management control system (EMCS) not having an override or bypass switch that allows the luminaire to be always on EXCEPTION 2: Outdoor luminaires used to comply with Exceptionl to §150(k)l3 may be controlled by a temporary override switch which bypasses the motion sensing function provided that the motion sensor is automatically reactivated within six hours. EXCEPTION 3: Permanently installed luminaires in or around swimming pool, water features, or other location subject to Article 680 of the California Electric Code need not be high efficacy luminaires. §150(k)l4: Internally illuminated address signs shall comply with Section 148; OR not contain a screw -base socket, and consume no more than five watts of power as determined according to §130(d). §150(k)l5: Lighting for parking lots and carports with a total of for 8 or more vehicles per site shall comply with the applicable requirements in Sections 130, 132, 134, and 147. Lighting for parking garages for 8 or more vehicles shall comply with the applicable requirements of Sections 130, 131, 134, and 146. §150(k)l6: Permanently installed lighting in the enclosed, non -dwelling spaces of low-rise residential buildings with four or more dwelling units shall be high efficacy luminaires. EXCEPTION: Permanently installed low efficacy luminaires shall be allowed provided that they are controlled by an occupant sensors certified to comply with the applicable requirements of 119. EnergyPro 5.1 by EnergySoft User Number: 6712 RunCode: 2011-03-02710:00:06 ID: Page 12 of 18 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name Knall Residence Date 3/2/2011 System Name A/C 1 Floor Area 1,514 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 COIL CFM Total Room Loads 1,139 Return Vented Lighting Return Air Ducts Return Fan Ventilation 0 Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COOLING PEAK COIL HTG. PEAK Heating System Sensible Latent CFM Sensible Output perSystem 71,000 20,619 1,745 673 22,854 Total Output Btuh 71,000 0 Output Btuh/s ft 46.9 1,190 1,123 Cooling System 0 0 Output perSystem 59,000 0 0 0 0 Total Output Btuh 59,000 0 1,190 1 22,999 1,745 0 Total Output ons 4.9 1,123 Total Output Btuh/s ft 39.0 Total Output s ft/Ton 307.9 1 25,100 Air System CFM perSystem 2,025 HVAC EQUIPMENT SELECTION Airflow cfm 2,025 Carrier 24ACB460/58DLX110 39,029 14,113 71,000 Airflow cfm/s ft 1.34 Total Adjusted System Output 39,029 (Adjusted for Peak Design conditions) 1 TIME OF SYSTEM PEAK 14,113 71,000 Aug.3 PM Jan 1 AM Airflow cfm/Ton 411.9 Outside Air % 0.0% Outside Air cfm/s ft 0.00 Note: values above given at ARI conditions HEATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26 OF 69 OF Outside Air 0 cfm Supply Fan 2,025 cfm 69 OF 69 OF 102 OF Heating Coil 102 OF ROQM 70 OF COOLING SYSTEM PSYCHROMETICS Airstream Temperatures at Time of Cooling Peak 112/78°F 79/66°F 79/66°F 60/59°F Outside Air 0 cfm Supply Fan Cooling Coil61 / 60 OF ......... _..... _._.... 2,025 cfm 52.2% ROOt1n 79 / 66 OF 78 ! 66 OF EnergyPro5.1 by EnergySoR User Number: 6712 RunCode: 2011-03-02710:00:06 ID: Page 13 of 18 • • C] ROOM LOAD SUMMARY Project Name Knall Residence System Name A/C 1 ROOM LOAD SUMMARY Date 3/212011 Floor Area 1.514 ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK Zone Name Room Name Mult. CFM Sensible Latent CFM Sensible Latent CFM Sensible Entire Residence Entire Residence 1 1,139 20,619 1,745 1,139 20,619 1,745 6731 22,854 PAGE TOTAL TOTAL* 1,139 20,619 1,745 673 22,854 1,139 20,6191 1,7451 673 22, 854 Total includes ventilation load for zonal systems. EnemyPrp 5.1 by EnemySoft User Number. 6712 RunCode: 2011-03-02710:00:06 ID: Pae 14 of 18 C� J • r� ROOM HEATING PEAK LOADS Project Name Knall Residence Date 3/2/2011 ROOM INFORMATION DESIGN CONDITIONS Room Name Entire Residence Floor Area 1,514.0 ft2 Indoor Dry Bulb Temperature 70 OF Time of Peak Jan 1 AM Outdoor Dry Bulb Temperature 26 OF Conduction Area U -Value X 0.0260 X 0.0675 X 0.4500 AT °F Btu/hr R-38 Roof Attic 1,514.0 X X X 44 = = = 1,732 R-13 Wall W 1"Faom 1,325.9 44 3,941 Double Tinted -Oyer 12.0 44 238 Double Tinted 134.5 X X X X 0.4700 X X X 44 = = = 2, 781 Wood Door 20.0 1.4500 44 1,276 Double Tinted -Doors 106.6 0.5100 44 2,392 Double Tinted -Window 71.0 0.4500 X 44 = 1,406 Slab -On -Grade Perim = 168.0 X 0.7300 X 44 = 5,396 X X X X X X = X X X X X X X X X = = X X X X X X X = X X X X X X = X X X X X X X X = = = = X X X X X X X X to another room 10.00 X 0.312 Ceiling Height ACH X = X = Page Total /60] X 44 AT Items shown with an asterisk (') denote conduction Infiltration:[ 1.00 X 1.064 Schedule Air Sensible Fraction through an interior surface X 1,514 X Area 19,162 = 3,692 TOTAL HOURLY HEAT LOSS FOR ROOM 22,854 Energ Pro 5.1 by Energ Soft User Number: 6712 RunCode: 2011-03-02710:00:06 ID: Page 15 of 18 • RESIDENTIAL ROOM COOLING LOAD SUMMARY X X X X X X X X X GLF + + + + + + + + + Project Name X X X X X X X X X GLF = = = = = = = = = Btu/hr Date Knall Residence 12.0 23.5 282 0.0 3/2/2011 ROOM INFORMATION 23.9 95 DESIGN CONDITIONS 23.9 25.0 23.9 Room Name Entire Residence Outdoor Dry Bulb Temperature 4.0 112 OF Floor Area 0.0 1,514.0 ft2 Outdoor Wet Bulb Temperature 23.9 78 OF Indoor Dry Bulb.Tem erature 23.9 78 OF Outdoor Daily Range: 941 0.0 34 OF 8.0 47.0 376 0.0 24.7 33.3 24.8 Opaque Surfaces Orientation Area U -Factor 1 10.0 CLTD' Btu/hr R-38 Roof Attic (N) 1,514.0 X 0.0260 X 56.0 = 2,204 R-13 Wall W 1 " Faom (N) 420.0 X 0.0675 X 23.0 = 653 R-13 Wall W 1 " Faom (E) 302.0 X 0.0675 X 33.0 = 673 Wood Door (E) 20.0 X 1.4500 X 33.0 = 957 R-13 Wall W 1 "Faom (S) 329.7 X 0.0675 X 26.0 = 579 R-13 Wall W 1"Faom (SK9 22.5 X 0.0675 X 31.0 = 47 R-13 Wall W 1 " Faom NO 251.7 X 0.0675 X 33.0 = 561 X X = X X = Page Total 5,674 Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Shaded Unshaded FP_nP_Stratlnn Window Window Window Window Window Window Window Window Window Orientation (N) (N) (N) (N) (N) (E) (E) (S) (s) Area X X X X X X X X X GLF + + + + + + + + + Area X X X X X X X X X GLF = = = = = = = = = Btu/hr 0.0 23.5 12.0 23.5 282 0.0 23.9 4.0 23.9 95 0.0 23.9 25.0 23.9 597 0.0 23.9 4.0 23.9 95 0.0 23.9 25.0 23.9 597 0.0 23.9 20.0 47.0 941 0.0 23.9 8.0 47.0 376 0.0 24.7 33.3 24.8 825 0.0 23.5 1 10.0 23.6 236 Page Total 4,043 Internal Gain Btu/hr Occupants 4.0 Occupants X 230 Btuh/occ. Equipment 1.0 Dwelling Unit X 1,600 Btu Infiltration: 1.064 X 0.87 X 82.85 X 34 = C Air Sensible CFM ELA AT I TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 20.6191 Latent Gain Btu/hr Occupants 4.0 Occupants X 200 Btuh/occ. = 800 Infiltration: 4,771 X 0.87 X 82.85 X 0.00276 = 945 Air Sensible CFM ELA AW • TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 1,7451 • RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Knall Residence ROOM INFORMATION DESIGN CONDITIONS Room Name Entire Residence Outdoor Dry Bulb Temperature Floor Area 1, 514.0 ft' Outdoor Wet Bulb Temperature Indoor Dry Bulb Temoerature 78 OF Outdoor Dally Ranae: Orientation r Date 3/2/2011 112 OF 78 OF 34 OF Area X X X X X X X X X U -Factor X X X X X X X X X CLTD' = = = = = = = = = 24.8 0.0 23.6 0.0 23.6 0.0 23.6 20.0 X X X X 24.8 6.0 24.0 0.0 32.8 0.0 32.8 15.4 X 47.8 Page Total Page Total Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Fenestration Window Window Window Window Window Window Window Window Window OriPntatinn (S) (S) (S) (S) (S) (S) (SM (SW) (tM Shaded Area Unshaded GLF Area 24.7 + 20.0 X 23.5 + 6.0 X 23.5 + 25.0 X 23.5 + 10.0 X 24.7 + 0.0 X 23.9 + 0.0 X 23.9 + 10.5 X 23.9 + 7.0 X 24.7 + 17.9 X GLF = = = = = = = = = 0.0 X X X X 24.8 0.0 23.6 0.0 23.6 0.0 23.6 20.0 X X X X 24.8 6.0 24.0 0.0 32.8 0.0 32.8 15.4 X 47.8 Page Total Btu/hr 0 Btu/hr 495 141 589 236 493 143 345 230 1.236 Internal Gain Btu/hr Occupants 4.0 Occupants X 230 Btuh/occ. Equipment 1.0 Dwelling Unit X 1,600 Btu Infiltration: 1.064 X 0.87 X 82.85 X 34 = Air Sensible CFM ELA AT I TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 20,6191 Latent Gain Btu/hr Occupants 4.0 Occupants X 200 Btuh/occ. = 800 Infiltration: 4,771 X 0.87 X 82.85 X 0.00276 = 945 Air Sensible CFM ElA AW • TOTAL HOURLY LATENT HEAT GAIN r� :7 • RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date KnaU Residence 1 3/2/2011 ROOM INFORMATION DESIGN CONDITIONS Room Name Entire Residence Outdoor Dry Bulb Temperature 112 OF Floor Area 1,514.0 ft' Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 78 OF Outdoor Daily Range: 34 OF Opaque Surfaces Orientation Area U -Factor, CLTD' Btu/hr X X = X X = X X = X X = X X = X X = X X = X X = X X = Page Total 0 Items shown with an asterisk (`) denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Shaded Unshaded Fenestration Orientation Area GLF Area GLF Btu/hr I/trndow (tM 10.0 X 23.5 + 0.0 X 46.6 = 235 Window (M 0.0 X 23.9 + 25.0 X 47.0 = 1,176 Window (tM 0.0 X 23.5 + 10.0 X 46.6 = 466 X + X - X + X - X + X - X + X - X + X - X + LX - Page Total 1,877 Internal Gain Btu/hr Occupants 4.0 Occupants X 230 Btuh/occ. = 920 Equipment 1.0 Dwelling Unit X 1,600 Btu = 1,600 Infiltration: 1.064 X 0.87 X 82.85 X 34 = 2,596 Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 20,619 Latent Gain Btu/hr Occupants 4.0 Occupants X 200 Btuh/occ. = 800 Infiltration: 4,771 X 0.87 X 82.85 X 0.00276 = 945 Air Sensible CFM ELA AW TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 1,745 EnemvPro 5.1 by EnemySoft User Number. 6712 RunCode: 2011-03-02T10:00:06 ID: Pae 18 of 18