13-1141 (SOL)P.O. BOX 1504
78-495 CALLE TAMPICO
LA QUINTA, CALIFORNIA 92253
Application Number: 13-00001141
Property Address: 77490 CALLE ARROBA
APN: 774-115-012-12 -000000-
Application description: SOLAR
Property Zoning: COVE RESIDENTIAL
Application valuation: 35000
4 VOICE (760) 777-7012
FAX (760) 777-7011
BUILDING & SAFETY DEPARTMENT INSPECTIONS (760) 777-7153
I
BUILDING PERMIT
Applicant: Architect or Engineer: U NOV Q 12013
Or
t
FINANCE DEPT
LICENSED CONTRACTOR'S DECLARATION
I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with
Section 7000) of Division 3 of the Business and Professionals Code, and my License is in full force and effect.
L'c�rtse Class: C10 -C46 L'ce se No.: 915598
Date: N0J/1f Contractor. H " `1'0 V"2 r
JOWNER -BUILDER DECLARATION
I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the
following reason (Sec. 7031 .5, Business and Professions Code: Any city or county that requires a permit to
construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the
permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State
License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or
that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by
any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500)•:
(_ 1 I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and
the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The
Contractors' State License Law does not apply to an owner of property who builds or improves thereon,
and who does the work himself or herself through his or her own employees, provided that the
improvements are not intended or offered for sale. If, however, the building or improvement is sold within
one year of completion, the owner -builder will have the burden of proving that he or she did not build or
improve for the purpose of sale.).
(_) I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec.
7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of
property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed
pursuant to the Contractors' State License Law.).
(_ 1 I am exempt under Sec. , B.&P.C. for this reason
Date:
Owner:
CONSTRUCTION LENDING AGENCY
I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the
work for which this permit is issued (Sec. 3097, Civ. C.).
Lender's Name:
Lender's Address:
LQPERMIT
Date: 11/01/13
Owner:
YOUNGMAN PHIL
77490 CALLE ARROBA
LA QUINTA, CA 92253
(908)967-0951.
Contractor:
HELIOPOWER INC
25767 JEFFERSON AVENUE
MURRIETA, CA 92562
(951)677-7755
Lic. No.: 915598
WORKER'S COMPENSATION DECLARATION
I hereby affirm under penalty of perjury one of the following declarations:
I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided
for by Section 3700 of the Labor Code, for the performance of the work for which this permit is
sued.
I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor
Code, for the performance of the work for which this permit is issued. My workers' compensation
insurance carrier and policy number are:
Carrier HDI-GERLING Policy Number EWGCC000110513
_ I certify that, in the performance of the work for which this permit is issued, I shall not employ any
person in any manner so as to become subje t to the workers' compensation laws of California,
and agree that, if I should become subject o he workers' compensation provisions of Section
3700 of the bor Code, I alrforth ith o ho provisions.
Date: t Applicant:
WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL
SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND
DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN
SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES.
APPLICANT ACKNOWLEDGEMENT
IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the
conditions and restrictions set forth on this application.
1 . Each person upon whose behalf this application is made, each person at whose request and for
whose benefit work is performed under or pursuant to any permit issued as a result of this application,
the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City
of La Quinta, its officers, agents and employees for any act or omission related to the work being
performed under or following issuance of this permit.
2. Any permit issued as a result of this application becomes null and void if work is not commenced
within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject
permit to cancellation.
I certify that I have read this application and state that the above information is rrect. Vagree to comply with all
city and county ordinances an state laws relating t0 building nstructi n, an er tho ' e rep esentatives
of thie�co my to enter the above-mentioned property f inspecti pur s.
Date: Signature (Applicant or Agent):
Application Number . . . . . 13-00001141
Permit . . . ELECTRICAL 2013
Additional desc . .
Permit Fee . . . . 23.83 Plan Check Fee
.00
Issue Date . . Valuation . . .
. 0
Expiration Date . . 4/30/14
Qty Unit Charge Per
Extension
1.00 23.8300 LS ELEC DEVICES, FIRST 20
23.83
----------------------------------------------------------------------------
Special Notes and Comments
7.OkW SOLAR ARRAY - (28) 25OW HYUNDAI
PANELS W/ (1) 6000W SOLAREDGE INVERTER
(476SF] 2010 CALIFORNIA ELECTRICAL CODE.
October 24, 2013 3:57:18 PM AORTEGA
----------------------------------------------------------------------------
Other Fees . . . . . . . . . BLDG STDS ADMIN (SB1473)
2.00
PLAN CHECK, ELECTRICAL
23.83
PERMIT ISSUANCE M/P/E
90.57
Fee summary Charged Paid Credited
----------------------------------------
Due
-----------------
Permit Fee Total 23.83 .00 .00
23.83
Plan Check Total .00 .00 .00
.00
Other Fee Total 116.40 .00 .00
116.40
Grand Total 140.23 .00 .00
140.23
LQPERMIT
Bin #
Qtyu of La Qulnta
B/Building &r Safety Division
P.O. Box 1504, 78-495 Calle Tampico
La Quinta, CA 92253 - (76Q) 777-7012
Building Permit Application and Tracking Sheet
Permit #
Project Address: -7-1 y q Q Tf-17VE
Owner's Name:
A. P. Number:
Address: P— ()
Legal Description:
City, ST, Zip:
Contractor:Telephone:0
C0�-�
Address: (1 A\)1E
Project Description: v
1� �p��r
(�
City, ST, Zip: u i � 1 eA-Ot C� -! S.2,
e m C)-'(
Telephone. b I 677- 775
. Sst*&
State Lic. # : City Lic. #;
Arch., Engr., Designer:
Address:
City., ST, Zip:
Telephone:
Construction Type: Occupancy:
Add'n Alter Repairait Demo
oProJecttyPa cir l w
State Lic. #:
Name of Contact Person:N'C\#Stories:t
#Units:
Telephone # of Contact Person: l " L�� —tel g 2
Estimated Value of Projec : r Q d
APPLICANT: DO NOT WRITE BELOW THIS LINE
#
I Submittal
Req'd
Recd
TRACKING
PERMIT FEES
Plan Sets
Plan Check submittedl
Item
Amount
Structural Calcs.
Reviewed, ready for corrections q
Plan Check Deposit
Truss Calcs.
Called Contact Person
Plan Check Balance.
Title 24 Calcs.
/
Plans picked up W
Construction
Flood plain plan
Plans resubmitted (gr#3
Mechanical
Grading plan
2'" Review, ready for correctio lissu
Electrical
Subcontactor List
Called Contact Person ®
Plumbing
Grant Deed
Plans picked up
S.M.I.
H.O.A. Approval
Plans resubmitted
Grading
IN HOUSE:-
'"' Review, ready for corrections/issue
Developer Impact Fee
Planning Approval
Called Contact Person
A.I.P.P.
Pub. Wks. Appr
Date of permit issue
School Fees
Total Permit Fees
qI�'3`���� S�uto. i�'c. •
lei�l J18�3 So�+ea. Ari --� tN�u t}�w►-� Q&4��,r -� r ��;�kc t �IA� 'c�
PV PHOTOVOLTAIC WIRE
° 600 VOLT
A P P L I C A T 10 N S Suitable for use as follows:
• For use in solar power applications
• Rated 90°C for exposed or concealed wiring in wet or dry locations
• Rated for direct burial
SPECIFICATIONS
• Stranded copper conductors
• XLP insulation
• UL Subject 4703
• UL 44
• UL 854
CONSTRUCTION
• Southwire PV Photovoltaic Wire is manufactured using stranded copper conductors with
single layer XLP insulation
• Bare or Tinned Conductors
• -40°C to +90°C
• Sunlight Resistant
• RoHS Compliant
• Direct Burial
• Sample Print Legend:
SOUTHWIRE E316464 (0) (UL) PV WIRE 10 AWG (5.26mm2) CU 600V 90'C WET OR
DRY (-40°C) SUN RES DIRECT BURIAL VW -1 OR USE -2 600V OR RHW-2 600V — RoHS
Other sizes and strand configurations are available upon request. Also available in various colors.
I—
AWG SIZE
NO. OF STRANDS INSULATION
THICKNESS
NOMINAL O.D.
NET WEIGHT
14
19
0.060
0.190
26.8
12
19
0.060
0.207
36.1
10
19
0.060
0.231
50.6
8
19
0.075
0.292
'80.3
14
7
0.060
0.190
26.8
12
7
0.060
0.207
36.1
10
7
0.060 11
0.231
50.6
8
7
1 0.075 1
0.292
1 80.3
Other sizes and strand configurations are available upon request. Also available in various colors.
STRANDED
COPPER p
CONDUCTORS p
.O
W
Bare or Tinned
Stranded Copper
Conductors
XLP Insulation
Direct Burial
-40°C to +90°C
600 Volts
UL green0s, Southwi
Umo RoHSComplient OEM Division
J
I—
J
\
O
STRANDED
COPPER p
CONDUCTORS p
.O
W
Bare or Tinned
Stranded Copper
Conductors
XLP Insulation
Direct Burial
-40°C to +90°C
600 Volts
UL green0s, Southwi
Umo RoHSComplient OEM Division
J
SHEET INDEX__
SHEET No.
DESCRIPTION
T-01
TITLE PAGE
PV -01
SITE PLAN
PV -02
ELECTRICAL
SINGLE LINE /
PV -02.1
PLACARDS/
CONDUIT CHART
PV -03
MOUNTING DETAIL
CUSTOMER INFO:
NAME:
YOUNGMAN, PHIL
ADDRESS:
77490 CALLE ARROBA
CITY:
LA QUINTA, CA 92253
PHONE:
908-967-0951
APN:
774115012
JURISDICTION:
LA QUINTA
YOUNGMAN, PHIL 7.0 kWDC PHOTOVOLTAIC SYSTEM
GaNeNk*t(i�eY.'�c
COMPANY:
NAME:
HELIOPOWER INC.
ADDRESS:
25767 JEFFERSON AVE.
CITY:
MURRIETA, CA 92562
PHONE:
--- 951-677-7755
FAX:
951-677-9559
CONTRACTOR 915598 CLASS C-46
LIC#:
YOUNGMAN, PHIL 7.0 kWDC PHOTOVOLTAIC SYSTEM
GaNeNk*t(i�eY.'�c
rrsw nwa
at
s a
}
size
B
NTS
a
A
aid
�
resistant material (i.e. engraved plastic). IsP
a
t•,M
Custom oft
L
Ca'k Crorg++a
Lot*
y
� 3
G
.
VIO-rlyr,
o.
S
3
Colic Artoba
Calle Avoba
I
a
6 C
�
fl
o
times rhornerey
rrsw nwa
CalleCrArm sme
�rrae manlrrcp
}
size
B
NTS
a
A
aid
�
resistant material (i.e. engraved plastic). IsP
a
t
Custom oft
L
0
VIO-rlyr,
S
3
TS
a,nne mcnnac, .
r I
CadeWirm
rrsw nwa
CalleCrArm sme
nate
Carte Clime
size
B
NTS
Drawn by
SV
A
aid
�
resistant material (i.e. engraved plastic). IsP
heel
T-01
Custom oft
0
CrOen
S
c
m
F4,pp
'
iR1lP
..
Celle Ar` e
..
Calk .4•r�
f:a.
Gre4*tms�
7
�
m
R
o
rrc�
Chdon Cade chlon Cane C:vllor.
1 VICINITY MAP
NTS
CONSTRUCTION NOTES:
1. Key Manufacturers are:
- Inverter, Solar Edge Technologies Inc.
900 Golden Gate Terrace Suite E
Grass Valley, CA 95945
- Panels, Hyundai Solar
1000 Bangeojin Circulation road,
Dong -Gu, Ulsan 682-792 Korea
- Racking, Professional Solar Products
4630 Calle Quetzal
Camarillo, CA 93012
- Solar PV System to be installed on a residential structure 1 story tall,
with 2X6 24" O.C. trusses.
- All components are UL listed and CEC certified, where warranted.
- The solar PV system will be installed in accordance with Article 690 of the 2010
NEC based on 2008 NEC and the 2010 CEC- 2010 CBG. A.
APPLICABLE CODES:
-All construction shall comply with the 2010 California Residential, Mechanical,
Electrical, Plumbing, Energy, and Green Building Codes and the La Quinta
Municipal Code.
- K 140001 *11413 UC 111 t IWAV IVI 111OPMAIV11 Ili YRIUI {rnL-v�7nn
regulations.
- This system is an utility interactive system with no storage batteries.
- The Solar PV installation shall not obstruct any plumbing, mechanical, or
building roof vents.
Cal 2 CI X01' c- t
vrA
IMI
2 FRONT VIEW
NTS
- A grounding electrode system in accordance with NEC 690-47 and 250-50 - A DC disconnecting means shall be installed at a readily accessible
through 60 and 250-166 shall be provided. Per NEC, grounding electrode location either outside of a building or structure or inside nearest the point of
system of existing building may be used and bonded to at the service entrance. entrance of the system conductors as per section 690-14 of the CEC.
If existing system is inaccessible or inadequate or is only metallic water piping, - Height of Integrated AC/DC Disconnect shall not Exceed 6'-7" per NEC 240.24
a supplemental grounding electrode will be used at the inverter location -The Grounding Electrode Conductor shall be protected from physical damage
consisting of a UL listed 8 ft ground rod with acorn clamp. Grounding electrode between the grounding electrode and the panel (or inverter) if smaller than #6
conductors shall be no less than #8AWG and no greater than #6AWG copper and copper wire per NEC 250.646. The Grounding Electrode Conductor will be
bonded to the existing grounding electrode to provide for a complete system. continuous, except for splices, or joints at busbars within listed equipment per
- Each module will be grounded using the supplied connections points identified NEC 250.64C.
on the module and the manufacturer's installation instructions. - Photovoltaic modules are to be considered non-combustible.
m LO LO
N04
Cr rn �o
WQcoLo
;QUCn
W ao 4
jJHCnti
- Exposed non-current carrying metal parts of module frames, equipments, and
conductor enclosures shall be grounded in accordance with 250.134 or 250.136 �� ��
(A) regardless of voltage.
-IID will be notified prior to use and activation of any solar installation. System CITY OF LA QUINTA
will be commissioned by owner per utility interconnection agreement.
- Proper access and working clearance around existing and proposed electrical BUILDING & SAFETY DEPT.
_ -4. z W
C) O Q
�-
equipment will be provided as per section 110.26 CEC.
- Alternate power source placard shall be plastic, engraved in a contrasting color APPROVEDPaper
to the plaque. This plaque will be attached by pop rivits or screws or other FOR CONSTRUCTIONsale
approved method. If exposed to sunlight, it shall be UV resistant
- Where metallic conduit containing DC conductors is used inside the building, it 400010
shall be identified as "Caution: High Voltage DC Circuit" every 5 feet. DATEt +s
- All plaques and signage req. by 2010 CEC will be installed as req. " 4W
-Signage and Labeling Specifications shall be: Red background with white "� P4 $4ft&, �!� .rnr
9 P g •
lettering, 318" letter heights, all capital letters, Arial or similar font, weather
size
B
NTS
Drawn by
SV
Title
TITLE PAGE
roject um er:
025.003
resistant material (i.e. engraved plastic). IsP
heel
T-01
X' 0)L".p W N
/�K0:) -0-0-0m i
�1Q�-O.uv 0m-om0 N
O _3 0 0 0 0 O O
\/ O
z- _ Z7N QQQ� QQQo Z
z v
N % CD 0
O w 0 0 0� 0 O —,� C>) y
'— `/� O N0 > >`° 0 0 m
m�/o _ novo o� I X
r-6
m ® � Q< N^' m CL N o z
Z 2r30 Q �N 0C/)>(D > -n
01 T)• p O O p�1 0 0 m ❑ o
%/ 0DV)� c- mpm- c;Itru m o I ❑
�, p c� me ��co a G I
XK N N 0 3
-400 > > mac°, o
om
OLnx Xao . <�
o� � � I D Z I
< C
c
rn
4
co
4
(0
o y m
— D
1 a 1
o � .c
CA 0 O
m o r
0-0
ZD-'
y
Z
O
w m N n v D D v m
�7rarmr-9 ^3 is
, a p a< m o a n=
aa m i^ � a n 0 3 a
�tonloa�cayn
m< m MOr " ^0m,
7vnr0(")�yoa� �a
001Crnl�tNn?mfD�mAo
m N p O 10 N x O.0,0
10/1
Aa m O.a O 7
7" ^ cr
a m D O m a 0.
rwwg
< 3 .
0m m
31 f nEcm
Om -10 0 CL
cr
moo. " : x
y m C N 7 C
ro o v 7y =. nm
= 7 fD 0 - m A -n
Cr
C c. ^
H O
N - 0 7 N O N y
^ c o a3 m
N m T o m 01 a
d X Q a a 0 C
n m % c O
O. j C O. m
o r^0omon
m rn
mmN + o ^ f1 N
v
Fonn� F
v m
0 N O 7< d A
0
m o oc n
rn
> > in(1 � m m
a orncn
no o
io ' 0 w
> � N o . m
m o n 0, m
^
v cr ° n (1
uci °i N N .�,
y
o N n L^w
y i m o.• m
O 0 O m
7 O bD C
O OO
3 — m �p 3
CI
m o
m o, a+
�cLD�o
CD
$mc)m
� I ;mD
0 n
m m
.�
N
O
N
v
mi
YOUNGMAN, PHIL
7.0 kWDC
s
25767 -JEFFERSON AV
CA
<
c
y
77490 CALLE ARROBA
PHOTOVOLTAIC
''//-
Murrieta, 92562
00
§
LA QUINTA CA 92253
/��
✓'
o
O
p ,
p
-0
ca
PHONE:908-967-0951
SYSTEM
HollieValtierra
HelioPower
P: (951)-677-7755
0
cn
F:(951) -677-9559o
w
W
Z
<
APN: 774115012
Lic# C-46 #915598
Solar Solutions, Engineered,
WW AEuoPOMR.COMn
o
CAUTION
VOLTAGEHIGH
DC CIRCUIT
STICKER LOCATED
EVERY 5 FEET ON EMT
BOND ALL METALLIC RACKING AND
PANEL FRAMING WITH ILSCO GBL-
4DBT GROUNDING LUGS
------------- 11
} + ++
1 2 313 P14
0 0 0
(1) STRING OF (14) HIS-M250MG
RIMMIN M
------ ----- ------------- - ----
1 2 3 000 13 P14
(1) STRING OF (14) HIS-M250MG
1 MODULE x 38.2 Voc = 38.2V
1 MODULE x 38.2 Voc x 1.14 = 43.54V
1 MODULE x 8.6 Isc x 1.25 = 10.75A
14 (STRINGS) x 1 (MODULES) x 250 (PMAX) / 350 Vdc = 10.0 Adc
'MPPT OPERATING RANGE WILL NOT EXCEED
55Vdc. (CONTROLLED BY THE OPTIMIZER).
TOTAL MAXIMUM STRING VOLTAGE
(CONTROLLED BY THE INVERTER) = 500Vdc
PV OUTPUT CIRCUIT CONDUCTOR
COLORS FOR UNGROUNDED
SYSTEMS (CEC 690.35)
BLUE -POSITIVE BLACK -NEUTRAL
EXISTING 200A SERVICE
200A MAIN CB
120 / 240V - 3 WIRE / 2 POLE /
1 PHASE/ 10kA AIC
I 200A I
f I
120/
I ! W I
Meter No.1 B4SR-146797 240V1 P a
Proposed bi-directional
meter # vz�
l�
*NOTE* NEUTRAL l
AND GROUND
BONDED HERE
l I
EQUIPMENT SCHEDULE
A&HYUNDAI HIS-M250MG SOLAR PANELS:
��SOLAR PASS-THROUGH BOX WITH
��----�/ SET -SCREW WIRE CONNECTORS IDEAL
PTC RATING 226.1
OB –SOLAREDGE POWER OPTIMIZER OP250-LV�,,�SOLAREDGE
MODEL NUMBER 22 UL LISTED (OR EQUAL)
SE6000A-US (240v) INVERTER
RATED DC INPUT POWER - 250 WATTS
WITH INTEGRATED DC/AC DISCONNECT
INPUT VOLTAGE RANGE - 5 TO 55 Vdc
RATED FOR 500V DC MAX POWER: 6000W
MAXIMUM INPUT CURRENT - 10 Adc
CEC EFFICIENCY: 97.5% MAX AC OUTPUT:
MAXIMUM OUTPUT CURRENT - 15 Adc
25A (@125% NEC)=31.25A '
STRING LIMITATIONS - 8 TO 21 MODULES
W cnp cno a
5200 WATTS STC PER STRING MAXIMUM
a SQ D D222NRB 60A RATED 35A FUSED AC
LL
OLL_
DISCONNECT, UL LISTED (OR EQUAL)
AC NAMEPLATE: 28X 226.1 X 0.975/1000 = 6.173kW
8/20/2013
—
W
>o
Z u) � V
Ir
ON �rn �u
U) S
U
W cnp cno a
lJ
LL
OLL_
_�
W a> u, J
W
2
0 0 o O
^ a6:
����
179 Q Qq
/n • \
N
CITY OF LA QUINTA
BUILDING & SAFETY DEPT.
APPROVED
FOR CONSTRUCTION
DATE BY
35A
WIRE AND CONDUI TYPICAL OF ONE
1.1 CONDUCTORS ARE (28 #12 PV WIRE A GROUND IS #10AWG BARE COPPER IN FREE AIR UNDER ARRAY
1.2 CONDUCTORS ARE (4) #10 PV WIRE A 1 OUND IS #10AWG BARE COPPER IN " CONDUIT OR LARGER.
1.3 CONDUCTORS ARE (4) #6 AWG USE -2 AND GROUND IS #10AWG THWN-2 COPPER IN Y4" CONDUIT OR LARGER
2.1 CONDUCTORS ARE (3) #8 AWG THWN-2 AND GROUND IS #8AWG THWN-2 COPPER IN Y4' EMT CONDUIT OR
2.2 BOND #6 AWG COPPER WITH IRREVERSIBLE SPICE OR LISTED ACORN CLAMP CONNECTION TO UFFER G.E.0
OVERCURRENT PROTECTION CALC
200A X 1.20%=240A
200A +35A =235A <240A
I m Lf) N LO
04 N_
0) O O
Q CO
QCiCD
W QO
j Q Z ti
j U Z Z
a 0 Q
nga
ti
B
Scale
NTS
Drawn by
SV
Title
SLD
Project Number:
025.003
PV -02
PLACARD LOCATED ON INTEGRATED PLACARD LOCATED FRONT STICKER LOCATED NEXT TO P.O.C. CIRCU�T PLACARD LOCATED AT INVERTER /
AC/DC DISCONNECT OF MAIN SERVICE PANEL BREAKER INSIDE MAIN SERVICE PANEL JUNCTION BOX / DISCONNECT
PLACARD LOCATED FRONT OF MAIN PLACARD LOCATED AT INVERTER PLACARD LOCATED FRONT OF AC DISCONNECT
SERVICE PANEL
CITY OF LA QUINTA
BUILDING & SAFETY DEPT.
APPROVED
FOR CONSTRUCTION
DATE By
--a-
A AmbientTerrverature --_
-107
Mirinum Historical Teffperaftn (F*)13
Min Cont Distance to Roof
3
Te Axe Adder ' 310.16(8)(2)c
40
WIRE RUNS, AMPACITY, VOLTAGE DROP AND CONDUIT REQUIREMENTS
147
Max Baled T
147,
Arfayoltage
Cutrent Carrying
Conductors
A Grounding
Conductors
A
B
C
= (A -B -C)
D
Amps
One-
# of
Maxvvl
Fuse or
Way
Design
Worst
Conduits
Select
Has
Wire
#Cnds in
Wire
Wlre
Tenn
Amps Amps
NEC
Breaker
DCI
Dist
Vdrop
#in
EGC
GEC
Case
Minimum
in
Max
Conduit
Wire Max
Neutral
Ampauity Conduit
Temp
Derated
Tenn
Ampatity
WireRtn P
Multiplier
Arrips
Min
Max
AC
d
Parallel
InsulQtv
AWG
Qtv AWG
Vdrop
Conduit
Parallel
Arms
Type
Term
Cord
g030C
Dente
Derate
Arros
Rati
30C
0"Module
To DC inizer 9.1 8.6
13.42
13.42
30.9
38.2
DC
2
2%
2 1
PV WIRE
1
10
02t%
Free -Air
1
Ck
Free -Air
141-158
N
40
1
0.58
23.2
90C
30
2.01689
DC OplirrimirtonBox Stim of 14 1 10_ L15 1
23.40 1
23.40
350
500
1 D
30
2% 1
2_ 1 t
f0 I PV WIRE I
1 1
-1
1,022%1FreeAir
I 1
I Ck -_I
Free -lir
141-158 1
N 1
55
1
0-58
.9
1 90C_1
40112WI7
JLwAon Box to hm of 14 1 10 1 15 1
23.40 1
23.40
1 350
500
1 DC I
W 1
2% 1
4 1 1
10
0.18% 1
39' EMT
1 1
Ck
1EMT
169--1767N1
5
1 q.8 1
0.41
itQ
90C 1
75
10.51824
r to PCIC_ .25 1
3125 1
35.00
1 211 1
264
AC 1
15 1
1% 1
3 1 1
1 8 1 THW4-2 1
1 1 8
1 t 1 6
026%
314* EMT
1
I Ck
I EMT 1
114-122 1
Y
55
1
0.8
5-i
75C 1
500.74367
A AmbientTerrverature --_
-107
Mirinum Historical Teffperaftn (F*)13
Min Cont Distance to Roof
3
Te Axe Adder ' 310.16(8)(2)c
40
Max"ExpectedModulelFree-AirTe F°
147
Max Baled T
147,
ro®tuurDurop v.otw
TatalAC VoltageRageDrop 028%
8/20/201
,m nLO
N
rvCDf�0
QQ C))
U
' W '
j -jCF)
i U 3 Z Z
IvaOQ
tiga.
Scale B
NTS
Drawn by
SV
Title
,OND/PLACARD
rotect um er:
025.003
PV -02.1
ch CCD
VJ NTJJ Z O C
O
O (cl)CD
.7 ? C
=
x D 73fl0
= O 0G 0)
6a-
mA �E0 Z O:.ZCaCD0�N
-0
^
r �O N ;u IN U3 C 7N
O d W 7— 7 fD N O_ 7: O
fn (D fD M m N N N N T
.r' A y 0 N d y .-. 3 0 V
Z ��. (D 3 D) d �, O O CM
o� C)a 41 v m (a c a C
y a Av C< O. n co 0
co °° co W c �
U) Sm
_ N X n 0 (D N 3
(D Co8° � O 7
CL
MAX. 7 (D O
CL O. O_
C
T
y,
7 N
a
_ _: -�
:% --=- k_
-------------- -.
mf V
2'-1"
MAX.
(E)
4,-0„
64.76"
1"
m
D -
(e� m X x o `c o o D cH r- o
a� X > O 9 A 3 3 -- (� 3
(n
O m w D D N N -4 Mm D p C m
'�-- () C Z O r O
fn r X m m D
SD O v O 2t!-r c n ri
m m --4 Z D r 2 c m r 0
O c = D -+ TT
r m m m
Z D
m = J
r m —1
p D
N
(n -4 c) 0) cn -n C 0 ?
�.�
v, r. cn cn
�0=r(Qoo�°-� N. o b g
r. m c m �' O=0 0) cm cm e� o
aa-c
CL a' mac --% CL a
CL m c (n Aw ...
(D .. (o o, 0 3 �
"► N tv
Uq 3Q
.� r►
(D G) CCD .. c a O D\ ^ D xk w
O Z" r OD N
co Ic O O N 0 m Q- M v cn n m �
O cn" N 0 B m �- C �-. ►1 C3 '� D O� D D
C. M � O QJ 0 c � 0 10 M rp a W. dR 0 (n (1) O r U)
-+. a) x n m rn �~+ c� m T C n z (n °r° (n
►� cn(c = p� �cci p � X r
mz
cn O an=-c'c ~� �' �� O OO o
N 3 N �► O O O '►� D C
N X "CS rn - i D 2
N ,�� y (D ((D �_ C < m-� k.J
O 0 C O O z
su CD CL Cn
(n
K).01
W
N Q o m q CA m 7PHIL
71 `- 25767 JEFFERSON AVEa
77490 CALLE ARROBA 7.0 kWDC: - Murrieta, CA 92562
a'. m PHOTOVOLTAIC •
l LA QUINTA, CA 92253 SYSTEM N
Q �' P: (951)-677-7755 0
C.4 p o N Z w PHONE: 908-967-0951 Rollie Valtierra a L�� P�ei' F: (951)-677-9559 w
W °—'• m APN: 774115012 Lie# C-46 #915598 Solar Solutions. Engineered. WWW.HELIOPOwER.COM o
aw
ate'
0
�
m
°'.w
0
•°,tip
o
�d
�
tl�
►tet
O
�'
�
�
�
~•
�
�
rOy�
00
�l •
�l
O
C7�
t�
l�
00
CO
INNOVATIVE 29970 Technology Drive, Suite 212
IS[STRUCTURAL Murrieta, CA 92563
t ENGINEERING Phone: (951) 600-0032
Fax: (951) 600-0036
Structural Calculations for:
Youngman Residence
7.OkWDC Photovoltaic Array Addition
77490 Calle Arroba
La Quinta, CA 92253
Owner/Developer.
HELIOPOWER INC.
25767 Jefferson Ave.
Murrieta, CA 92562
October 3, 2013
ISE Job#: 13-2114
OQApFE Sjo
Z o
s 627 � in
Exp. 6/30/14
op
INNOVATIVE
STRUCTURAL
ENGINEERING
29970 Technology Drive, Suite 212
Murrieta, CA 92563
Phone: (951) 600-0032
Fax: (951) 600-0036
I SOLAR RESIDENTIAL ROOF/BUILDING CHECK I
I Check Photovoltaic Array Addition at Buildings - 2010 California Building Code (CBC) I
Roof Type: Conc. Tile over 1/2" sheathing over Mfr. Trusses over 5/8" gypsum board
Live Load:
20.0 psf
Dead Load:
Total Roof Load w/o Solar Array
1 35.0 Ipsf
Roofing Material:
5.0
psf
Sheathing:
1.5
psf
Roof Framing Members:
3.0
psf
Drywall:
3.0
psf
Insulation:
1.0
psf
Miscellaneous:
1.5
psf
Solar Array & Rack System
2.58
psf — Additional Load Applied
Roof Dead Load w/o Solar Array
1 15.00
1psf Over < 50% of Roof Area
Roof Dead Load at Solar Array =
1 17.58
Ipsf
Check Additional Gravity Loads on Trusses: DATE BY
Total Load Increase at Affected Trusses = 0.77 Ipsf
Percentage of Total Load Increase = 2.20% 1 < 5.0% OK
:. Per CBC 3403.2 Additional Solar Array
Weight Is Structurally Acceptable
Check Additional Gravity Loads on Lateral Resisting System:
Dead Load Increase at Entire Roof = 0.77 psf
Prct. Dead Load Increase on Entire Roof = 5.13% < 10.0% OK
:. Per CBC 3403.2.3.1 Additional Solar Array
Lateral Load Is Structurally Acceptable
Total Roof Load w/o Solar Array
1 35.0 Ipsf
Total Roof Load at Solar Array =
37.6 psf
CITY OF LA Q U I N Ti
Area of Solar Array Addition (for gravity check) =
487 fe
BUILDING & SAFETY DEF
Total Area of Affected Trusses (for gravity check)
1632 ft'
APPROVED
Area of Solar Array Addition (for seismic check) =
487
Total Area of Affected Roof (for seismic check) =
1632 ft'
FOR CONSTRUCTION
Check Additional Gravity Loads on Trusses: DATE BY
Total Load Increase at Affected Trusses = 0.77 Ipsf
Percentage of Total Load Increase = 2.20% 1 < 5.0% OK
:. Per CBC 3403.2 Additional Solar Array
Weight Is Structurally Acceptable
Check Additional Gravity Loads on Lateral Resisting System:
Dead Load Increase at Entire Roof = 0.77 psf
Prct. Dead Load Increase on Entire Roof = 5.13% < 10.0% OK
:. Per CBC 3403.2.3.1 Additional Solar Array
Lateral Load Is Structurally Acceptable
INNOVATIVE 1 29970 Technology Drive, Suite 212
IS I STRUCTURAL Murrieta, CA 92563
ENGINEERING (951) 600-0032, (951) 600-0036 Fax
ROOF MOUNTED SOLAR PANELS
Desi n Parameters
Oita Class =
Short Period S.A., 5s =
Site Coefficient, F. =
5me = F.O. =
ODs = 2/3 5me =
Importance Factor, Ip =
Height of Equipment, z =
Height of Koaf, h =
Weight of Panels to each Mount, Wp =
ap =
Rp =
D
Per Table 1613.5.2
LOGO
Table 1613.5.3(1)
EQ 16-37
EQ 16-39
Section 13.1.3
ft
ft
lbs
Table 13.6-1
Table 13.6-1
1.500
1.00
1.50
1.00
1.00
15.00
15.00
40.80
1.00
2.50
Determine Fp, 5eismic Design Force (STRENGTH LEVE
Fp = (0.4ap5DSWp)(1+2,z/h) / (RP/Ip) = 20lbs EQ 13.3-1
[Not Greater Than:] Fp = 1.650^lp = 65 lbs EQ 13.3-2
8/16/2013) = 0.35DyWplp = 12 lbs EQ 13.3-3
Therefore, Use Fp = 20 lbs at each Roof Mount Bracket
INNOVATIVE
IS I STRUCTURAL
ENGINEERING
29970 Technology Drive, Suite 212
Murrieta, CA 92563
(951) 600-0032, (951) 600-0036 Fax
I ROOF MOUNTED SOLAR PANELS
Components and Cladding - Wind Load Design per ASCE 7-05.6.5.12.4 - h<60 ft
1175475 Design end Velocity (30 Gust), V =
85
mph
Wind Exposure =
C
GCp (Z�ne 2)=
Mean Panel Height =
15.00
ft
Total Effective Area of Typical Array =
487
ft2
Panel Area to Each Support =
16.25
fe
Angle of Panels =
1
degrees
"a" =
3
ft (3ft. Min.)
-6
Determine Wind Force at Each Koaf Mount
olh = 0.00256 KZ Kn Ka I =
13.4
psf
K= =
0.85
Table 6-3, Page 79
Kn =
1.0
Figure 6-4, Page 45-46
Ka =
0.85
Table 6-4, Page 80
I =
1.00
GCp (Zone 1) =
0.28
-0.97
Per Figures 6.11 thru 6.16
GCp (Z�ne 2)=
0.30
-1.60
Per Figure9 6.11 thru 6-16
GCp (Zone 3)=
0.30 1
2.40
(NO PANELS IN ZONE 3 IN THIS PROJECT)
(+) P = qh (GCp - GCp,) = 1
10.0
-21.4
psf, Positive Wind (10 psf min) - Worst Case
Lateral Load at Each Mount =3
-6
lbs
Compression / Uplift at Each Mount =1
162
-347
lbs
Roof Mount /e attavohed to rmf ehawMM8 & rwfinemAww w/ (1) 540"x 342%.## ZlWt w/M/n. 2" throws)
Embed psr He& Poxer
Allowable Loads for 5/16' Dlameter Lag Screw per the 2005 NDS:
(Table 11.2A) Wfthdrawl= Ib/in x 2.0" x (Cd = 1.6) = 851 Ibs
(Table 11K) Shear=Ea:d Ib x (Cd =1.6) 1 192 1 lbs
90LAR ARRA YATTAO MEW METHOD 19 579LICIVRALL YACCEMOLE1111//
CITY OF LA QUINTA
BUILDING & SAFETY DEPT.
APPINU
FOR CONSTRUCTION
DATE BY
www.hyundaisolar.com
0
H a o
Mvadu�e
Multi -crystalline Type
HiS-M240MG I HiS-M245MG I HiS-M250MG
MG -Series Mono -crystalline Type
HiS-S255MG I HiS-S260MG HiS-S265MG
Mechanical Characteristics
High Quality
• IEC 61215 (Ed.2) and IEC 61730 byTUV Rheinland
UL listed (UL 1703), Class C Fire Rating
Output power tolerance +3/-0 %
ISO 9001:2000 and ISO 14001:2004 Certified
Advanced Mechanical Test (5,400 Pa) Passed (IEC)
/ Mechanical Load Test (40 Ibs/ft') Passed (UL)
Ammonia Corrosion Resistance Test Passed
IEC 61701 (Salt Mist Corrosion Test) Passed
Fast and Inexpensive Mounting
Delivered ready for connection
Pre-confectioned cables
IEC (UL) certified and weatherproof connectors
Integrated bypass diodes
Limited Warranty
10 years for product defect
10 years for 90 % of warranted min. power
25 years for 80 %of warranted min. power.
x Important Notice on Warranty
The warranties apply only to the PV modules with Hyundai Heavy Industries Co., Ltd:s
logo (shown below) and product serial number on it.
O %r __ ` N
a
ul N� Pt/ CYCLE: C E
HYUNDAI
HEAVY INDUSTRIES CO,LTD.
Electrical Characteristics -
Multi -crystal line Type
983 mm (38.7")(W) x 1,645 mm (64.76")(L) x 35 mm (1.38")(H)
•r
Approx. 18.5 kg (40.8 lbs)
• .
60 cells in series (6 x10 matrix) (Hyundai cell, Made in Korea)
&V0900
4 mm' (12AWG) cables with polarized weatherproof connectors,
IEC certified (UL listed), Length 1.0 m (39.4")
ft..YS
H IP65, weatherproof, IEC certified (UL listed)
.. ... -
3 bypass diodes to prevent power decrease by partial shade
A
Front: High transmission low -iron tempered glass, 3.2 mm (0.126)
Encapsulant:EVA Back Sheet: Weatherproof film
8.0 8.1
Clear anodized aluminum alloy type 6063
High Quality
• IEC 61215 (Ed.2) and IEC 61730 byTUV Rheinland
UL listed (UL 1703), Class C Fire Rating
Output power tolerance +3/-0 %
ISO 9001:2000 and ISO 14001:2004 Certified
Advanced Mechanical Test (5,400 Pa) Passed (IEC)
/ Mechanical Load Test (40 Ibs/ft') Passed (UL)
Ammonia Corrosion Resistance Test Passed
IEC 61701 (Salt Mist Corrosion Test) Passed
Fast and Inexpensive Mounting
Delivered ready for connection
Pre-confectioned cables
IEC (UL) certified and weatherproof connectors
Integrated bypass diodes
Limited Warranty
10 years for product defect
10 years for 90 % of warranted min. power
25 years for 80 %of warranted min. power.
x Important Notice on Warranty
The warranties apply only to the PV modules with Hyundai Heavy Industries Co., Ltd:s
logo (shown below) and product serial number on it.
O %r __ ` N
a
ul N� Pt/ CYCLE: C E
HYUNDAI
HEAVY INDUSTRIES CO,LTD.
Electrical Characteristics -
Multi -crystal line Type
X All data at STC (Standard Test Conditions). Above data maybe changed without prior notice.
Mono -crystalline Type
000
•r
.
Nominal output (Pmpp)
W
240
245 250
Voltage at Pmax (Vmpp)
Current atPmax (Impp) _
V
30.5
30.7 30.9
A
7.9
8.0 8.1
Open circuit voltage (Voc)
V
37.7
38.0 38.2
Short circuit current (Isc)
A
8.3
8.4 8.6
Output tolerance
%
+3/-0
No. of cells & connections
PCs
60 in series
Cell type
_
6"Multi-crystalline silicon (Hyundai cell, Made in Korea)
Module efficiency
%
i,
14.8
15.2
15.5
Temperature coefficient of Pmpp
%/K
-0.43
-0.43
-0.43
Temperature coefficient ofVoc
%/K
-0.32
-0.32
-0.32
Temperature coefficient of Isc
%/K
0.048
0.048
0.048
X All data at STC (Standard Test Conditions). Above data maybe changed without prior notice.
Mono -crystalline Type
X -All data at STC (Standard Test Conditions). Above data may be changed without prior notice.
Module Diagram I (unit: mm, Inch) I-V Curves
Installation Safety Guide
ADD -(3937) 1M-093'1
-WCABLE& 4m CABIE&
ONWICTOR COMCIDR
GR"D MARK
4XC42
GRDLND HOLE
• Only qualified personnel should install or perform maintenance.
Be aware of dangerous high DC voltage.
Do not damage or scratch the rear surface of the module.
Do not handle or install modules when they are wet.
F C -(AI
a.5 3Y) Inftl.tra.=l.(IOOW/m' '
DETAILA _0P "c6Tmp"Te
-Oµrdng CdlTm =2SC
. SLOTTHRU -DR "CeUTi V-4SC
a -Dpa yiy4-0TaT_6SC
4 s ro .1 n n
8 3 I n
C (AI vdr.g.tn
Cdav2d• I IOOWmi
.Ma 42.•1 oowm ''.
DETAILS Nddv2d•90oW/ '
IB(0.11a kdd02d=aIO
W/
I..
1 _ I CA,m'P•2SC '
SECT NCC 4 S io ,5 24 Ss
m volleg.lvl
Nominal Operating Ce`II'Temperature
[OperaiingsTemperatur r
. Stt
Maximum ystemVoltage
� .55
[Maximu m_Reverse_Current
Sales & Marketing
2e0 FI., Hyundai Bldg.,75, Yul ok-ro, Jon no- u, Seoul 110-793, Korea
FSC 9 9 9
Tel: +82-2-746-8406,7422,8525 Fax: +82-2-746-7675
( Printed Date: April 20131
r '•
HYUNDAI
HEAVY INDUSTRIES CO -.LTD.
000
.4
Nominal output (Pmpp)
W
255
260 265
_Voltage at Pmax (Vmpp) _
V
30.8
31.0 31.2
Current at Pmax (Impp)
A
8.3
8.4 8.4
Open circuit voltage (Voc)
V
37.7
37.8 37.9
Short circuit current (Isc)
A
8.8
8.9 1 9.0
_Output tolerance _
%
+3/-0
No. of cells & connections
PCs
60 in series
Cell type
6"Mono-crystalline silicon (Hyundai cell, Made in Korea)
Module efficiency
%
15.8
16.1
16.4
Temperature coefficient of Pmpp_
%/K
-0.45
-0.45
-0.45
Temperature coefficient ofVoc
%/K
-0.33
-0.33
-0.33
Temperature coefficient of Isc
%/K
0.032
0.032
0.032
X -All data at STC (Standard Test Conditions). Above data may be changed without prior notice.
Module Diagram I (unit: mm, Inch) I-V Curves
Installation Safety Guide
ADD -(3937) 1M-093'1
-WCABLE& 4m CABIE&
ONWICTOR COMCIDR
GR"D MARK
4XC42
GRDLND HOLE
• Only qualified personnel should install or perform maintenance.
Be aware of dangerous high DC voltage.
Do not damage or scratch the rear surface of the module.
Do not handle or install modules when they are wet.
F C -(AI
a.5 3Y) Inftl.tra.=l.(IOOW/m' '
DETAILA _0P "c6Tmp"Te
-Oµrdng CdlTm =2SC
. SLOTTHRU -DR "CeUTi V-4SC
a -Dpa yiy4-0TaT_6SC
4 s ro .1 n n
8 3 I n
C (AI vdr.g.tn
Cdav2d• I IOOWmi
.Ma 42.•1 oowm ''.
DETAILS Nddv2d•90oW/ '
IB(0.11a kdd02d=aIO
W/
I..
1 _ I CA,m'P•2SC '
SECT NCC 4 S io ,5 24 Ss
m volleg.lvl
Nominal Operating Ce`II'Temperature
[OperaiingsTemperatur r
. Stt
Maximum ystemVoltage
� .55
[Maximu m_Reverse_Current
Sales & Marketing
2e0 FI., Hyundai Bldg.,75, Yul ok-ro, Jon no- u, Seoul 110-793, Korea
FSC 9 9 9
Tel: +82-2-746-8406,7422,8525 Fax: +82-2-746-7675
( Printed Date: April 20131
r '•
HYUNDAI
HEAVY INDUSTRIES CO -.LTD.
s®iarKoo
SolarEdge
S0
ingle Phase Invert�e
(North America)
The only inverters specially designed for distributed DC architecture
o Superior efficiency (97.5%)
o Small, lightweight and easy to install on provided bracket
a Built-in module -level monitoring I
i
o Communication to internet via Ethernet or Wireless 40
a Outdoor and indoor installation
O Integral AC/DC Switch 1
f�
SE3000A-US
ve: I t
SE380OA-US - SE7000A-US
architects of energ.Y-
1
`A .t
Single Phase Inverters
SE3000A- U S/SE13800A- U S/SE5000A- U S/
S:E6000A U_S/LS E�7000A U S
All our inverters are part of SolarEdge's innovative system designed
to provide superior performance at a competitive price. The SolarEdge
inverter combines a sophisticated, digital control technology and a one
stage, ultra -efficient power conversion architecture to achieve superior
performance - over 97% efficiency and best -in -class reliability. Our fixed -
voltage technology ensures the inverter is always worki ngat its optimal input
voltage, regardless of the number of modules or environmental conditions.
A proprietary data monitoring receiver is integrated in the single phase
TECHNICAL DATA
inverter and aggregates SolarEdge power optimizer's performance
data from each PV module. Multiple inverters can be connected in an
RS485 bus or using a wireless Zigbee MESH network. The data from the
solar inverters is transmitted to the web using an Ethernet connection
or a wireless link and can be accessed via the SolarEdge Monitoring
Portal for performance analysis, fault detection and troubleshooting.The
inverter comes with an AC/DC safety switch and is light enough for a
single person to install on a supplied bracket.
• •The following Pen Numbers ere arelleble (CAN PNs are eligible for Na Ontario Fl7 and mlcraFlT):
SE3000A-US
I SE380OA-US SE5000A-US SE6000A-US SE7000A-US
277V, min, operating temp -4F/-20C: SE5000Ad1S, SE6000A-US. SE7000A-US
208/240V min. operating temp AOF/.40C: SE3000A-US4CAN, SE3800A-USCAN, SE5000ALS CAN, SE6000AUS-CAN
Rated AC Power Output
3000
3800
5000
5200@208V
6000@240V
6000@277V
5200@208V
6000@240V
7000@277V
W
Max. AC Power Output
3000
3800
5000
5200@208V
6000@240V
6000@277V
5200@208V
6000@240V
7000@277V
W
AC Output Voltage Min. -Nom. -Max.
183 - 208 - 229 /
211- 240 - 264
183 - 208 - 229 / 211- 240-264 / 244 277 - 294
Vac
AC Frequency Min. -Nom. -Max.
59.3 - 60 - 60.5
Hz
Max. Continuous Output Current @208V
14.5
18.5 24 25 25
A
Max. Continuous Output Current @240V
12.5
16 21 25 25
A
Max. Continuous Output Current @277V
18.5 22 25
A
GFDI
1
A
Utility Monitoring, Islanding Protection, Country Configurable Thresholds Yes
Recommended Max. DC Power * (STC)
3750
4750 1 6250 1 7500 1 8750
W
Transformer -less, Ungrounded
Yes
Max. Input Voltage
500
Vdc
Nom. DC Input Voltage
325 @ 208V / 350 @ 240V / 400 @ 277V
Vdc
Max. Input Current
10
12.5 16 18 18.5
Adc
Reverse -Polarity Protection
Yes
Ground -Fault Isolation Detection
60OkQ Sensitivity
Maximum Inverter Efficiency
97.8
97.7
98.3
98.3 98.3
%
CEC Weighted Efficiency
97.5
97 @ 208V /
97.5@ 240V
97.5@ 208V, 240V
/ 98 @ 277V
97 @ 208V / 97.5@ 240V /
98 @ 277V
%
Nighttime Power Consumption
< 2.5
W
111 fill 111MM-
Supported Communication Interfaces
RS485, RS232, Ethernet, Zigbee (optional)
Safety
UL1741, IEC -62103 (EN50178), IEC -62109
Grid Connection Standards
Utility -Interactive, VDE 0126.1-1, AS -4777, RD -1663 , DK 5940, IEEE1547
Emissions
FCC part15 class B, IEC61000.6.2, IEC61000-6-3, IEC61000-3-11, IEC61000-3-12
RoHS
Yes
mpff-MVIN MW
AC Output
3/4" Conduit
DC Input
3/4" Conduit
Dimensions (HxWxD)
21 x 12.5 x 7 /
540x315x172
21 x 12.5 x 7.5 / 540 x 315 x 191
in/ mm
Dimensions with AC/DC Switch (HxWxD)
30.5 x 12.5 x 7 /
775x315x172
30.5 x 12.5 x 7.5 / 775 x 315 x 191
in/mm
Weight
42/19
45/20.5
Ib / kg
Weight with AC/DC Switch
48.5/22
52/23.5
Ib / kg
Cooling
Natural Convection
Min. -Max. Operating Temperature Range
-4 / -20 (CAN version -40 / -40) to +140 / +60
'F/ 'C
Protection Rating I
NEMA 3R
• •The following Pen Numbers ere arelleble (CAN PNs are eligible for Na Ontario Fl7 and mlcraFlT):
� SiRISF+EC J6L CIE
208/240V, min. operating temp AF/.20C: SE3000A.US. SE3800AUS, SESOOOA-US, SE6000AuS, SE7000A uS
277V, min, operating temp -4F/-20C: SE5000Ad1S, SE6000A-US. SE7000A-US
208/240V min. operating temp AOF/.40C: SE3000A-US4CAN, SE3800A-USCAN, SE5000ALS CAN, SE6000AUS-CAN
277V, min operating temp.40F/AOC: SE5000A-USCAN, SE6000AUSCAN, SE7000AUSCAN
USA 900 Golden Gate Terrace, Suite E, Grass Valley CA 95945, USA
Germany Bretonischer Ring 18.85630 Grasbrunn (Munich), Germany
Japan B-9 Ariake Frontier Building, 3-7-26 Ariake, Koto-Ku, Tokyo 135-0063, Japan
solar d°
Israel 6 HeHardsh St. PO.Box 7349, Neve Neeman, Hod Hasharon 45240, Israel
www.sclaredge.com
architects orenergy-
O SolarEdge Technologies, Inc. 20042011 . All rights reserved. SOLAREDGE. the SolarEdge logo, ARCHITECTS OF ENERGY and OPTIMIZED BY SOLAREDGE are trademarks or registered trademarks of SolarEdge Technologies.
Inc. All other trademarks mentioned herein are trademarks of their respective owners. Date: 01/2012. V02.Sub)ect to change without notice.
soar 0 Xo-.
SolarEdge Power Optlimizer
Mlold u Ile Ad d;�Oln
At
IOU
�� a•
Oil
y) re t
4-
A
-
A superior approach to maximizing the throughput of photovoltaic
systems using module embedded electronics
o Up to 25% increase in power output
o Superior efficiency (99.5%) - peak performance in both mismatched and unshaded conditions
t3 Flexible system design for maximum space utilization
o Next generation maintenance with module level monitoring and smart alerts
a Unprecedented installer and firefighter safety
o The most cost effective solution for residential, commercial and
large field Installations
architects of energyTM
OP250-LV OP300- V
OP400-MSV
HIGHLIGHTS
a Module level MPPT - optimizes each module independently
a Dynamically tracks the global maximum operating point for both
modules and PV inverter
o Module -level monitoring for automatic module and string level
fault detection allowing easy maintenance
c Electric arc detection - reduces fire hazards
o Unprecedented installer and firefighter safety mode - safe module
voltage when inverter is disconnected or off
o Connection of one or more modules to each power optimizer
TECHNICAL DATA
a Lower installation costs with faster design, less wiring, DC
'disconnects and fuses
o Easy and flexible installation — use the same installation methods
as exist today
o Allows parallel uneven length strings and multi -faceted
installations
n Allows connection of different module types simplifying inventory
considerations
o Immediate installation feedback for quick commissioning
USA 900 Golden Gate Terrace, Suite E, Grass Valley CA 95945, USA
Germany Bretonischer Ring 18, 85630 Grasbrunn (Munich), Germany G G. (` solar o° °
Japan B-9 Ariake Frontier Building, 3-7-26 Ariake, Koto-Ku, Tokyo 135-0063, Japan architects of energy -
Israel 6 HeHarash St. PO.Box 7349, Neve Neeman, Hod Hasharon 45240, Israel www.solaredge.com
O solarEdge Technologies, Inc. 20032011 . All rights reserved. SOLAREOGE, the SolarEdge logo, ARCHITECTS OF ENERGY and OPTIMIZED BY SOLAREDGE are trademarks or registered trademarks of
SolarEdge Technologies, Inc. All Other trademarks mentioned herein are trademarks of their respective owners. Date: 01/2012. Subject t0 change without notice.
OP250-LV OP300-MV/OP400-MV
Rated Input DC power
250 300/400
W
Absolute Maximum Input Voltage (Voc)
55 75
Vdc
MPPT Operating Range
5-55 5-75
Vdc
Maximum Input Current
10 10
Adc
Reverse -Polarity Protection
Yes
Maximum Efficiency
99.5
%
European Weighted Efficiency
98.8
%
CEC Weighted Efficiency
98.7
%
Inductive Lightning Protection
1
m / ft
Overvoltage Category
II
•i D� • ► .. .. • •• . •• ••
Maximum Output Current
15
Adc
Operating Output Voltage
5-60
Vdc
Total Maximum String Voltage (Controlled by
Inverter) - US and EU 1 -ph
500
Vdc
Total Maximum String Voltage (Controlled by
Inverter) - EU 3 -ph
950
Vdc
90W' eOR�•• • •' 1 r • •(�•�u7 r • •
Safety Output Voltage per Power Optimizer
1
Vdc
G;1®CmQil
Minimum Number of Power Optimizers per
String (1 or More Modules per power optimizer)
8 (1 -ph system) / 16 (3 -ph system)
Maximum Number of Power Optimizers per
String (1 or More Modules per power optimizer)
Module power dependent; typically 20 - 25 (1 -ph system) /
45 - 50 (3 -ph system)
Parallel Strings of Different Lengths or
Orientations
Yes
T.T. •
EMC
FCC Part15 Class B, IEC61000-6-2, IEC61000-6-3
Safety
IEC -62103 (class II safety), UL1741
Material
UL -94 (5 -VA), UV Resistant
RoHS
Yes
Dimensions (WxLxH)
120x13Ox37 / 4.72x5.11x1.45
mm / in
Weight
450/1.0
gr / Ib
Output PV Wire
0.95 m / 3 ft length ; 6 mm2 ; MC4
Input Connector
MC4 / Tyco / H+S / Amphenol — H4
Operating Temperature Range
-40 - +65 / -40 - +150
C / OF
Protection Rating
IP65 / NEMA 4
Relative Humidity
0-100
%
USA 900 Golden Gate Terrace, Suite E, Grass Valley CA 95945, USA
Germany Bretonischer Ring 18, 85630 Grasbrunn (Munich), Germany G G. (` solar o° °
Japan B-9 Ariake Frontier Building, 3-7-26 Ariake, Koto-Ku, Tokyo 135-0063, Japan architects of energy -
Israel 6 HeHarash St. PO.Box 7349, Neve Neeman, Hod Hasharon 45240, Israel www.solaredge.com
O solarEdge Technologies, Inc. 20032011 . All rights reserved. SOLAREOGE, the SolarEdge logo, ARCHITECTS OF ENERGY and OPTIMIZED BY SOLAREDGE are trademarks or registered trademarks of
SolarEdge Technologies, Inc. All Other trademarks mentioned herein are trademarks of their respective owners. Date: 01/2012. Subject t0 change without notice.
9/29/2010 https://www.ilsco.com/ProductsDetail....
. Search Seardt Options Home Login Register
Exoand <imane src=hitos//www.il...o.com/rimaoeslabout usoif title='about usl> ®Expand <imaoe 2='httDa/fwww.its o.com/limaaesIProductsair title=products/>
NWRIWIMIN
aoe . c='httos//www.ilsro.com//imaoegrefemnce.oif title_ reference'/> Expand <imaae src='Mips//www.il vo.com//imaoe9cudomer service.olf lille='custom
,
!ma�Mce'/�xpand <Imaae s-'https//www.ilmo.com//images/contact us.oif title='contact usl>
�CGBL - LAY -IN DIRECT BURIAL
• Manufactured from high strength copper alloy with stainless steel screw.
• UL listed and CSA certified for direct burial in earth or concrete.
• Tested to UL 467.
• Lay -in feature for ease in installation.
• For copper conductor only.
• Rated for grounding and bonding.
• Rated for 600 Volts.
• Add a T to the end of the catalog number for Tin Plated oersion as shown below.
• UL File E34440.
Item ID
Ground Conductor Range Length Width Height Bolt/Stud Size Hex Size Plating Standard Package Quantity NAE)UPC Number
GBL -4D8
4-14 AWG
1.1500 0.3750 0.8250 10
S
Clear
50
78366996017
GBL-4DBT
4-14 AWG
1.1500 0.3750 0.8250 10
S
Tin
50
78366996018
GBL-4DB-14
4-14 AWG
1.1500 0.4720 0.8250 1/4
S
Clear
50
78366996019
GBL-41)BT-14 4-14 AWG
1.1500 0.4720 0.8250 1/4
S
Tin
50
78366996020
iisco.com/ProductsDetaii.aspx?Mkff=6..,.
RETURN
Privacy Statement
1/1
HeHoPower
Engineering Energy Solutions since 2001
Plan Corrections — Residential PV
77490 Calle Arroba, La Quinta CA, 92553
Plan Check # 13-1141
1St review
Corrections List:
-Section A - General
1. Attached structural calculations stamped and signed
2. Codes note added to T-01
-Section B — Solar
IV. Wiring Methods
1. Conductor size adjusted', accordingly, added to PV -02 and PV -02.1
2. Exposed conductors shall be PV listed, note added to PV -02 and PV -02.1
V. Grounding
1. GEC (2.3) changed to (2.2) on PV -02
VI. Marking, Connection to Other Sources, Storage Batteries and Systems over 600V
1. Note added to PV -02
Section C — Structural
1. Engineering calculations provided
Salvador Villegas
Assistant Manager, Residential Design
Office: 951-677-7755
Direct: 760-284-3463
ww.HelioPower.com
Toll Free: 187 SOLAR 888
California Contractor's License: 915598
Nevada Contractor's License: 007111
idquarters
Sacramento
San Francisco
Palm Desert
'67 Jefferson Avenue
201 Harris Avenue, Suite 15
100 Montgomery Street, Suite 1055
75178.Gerald Ford Drive - Suite 3A
rrieta, CA 92562
Sacramento, CA 95838
San Francisco, CA 94104
Palm Desert, CA 92211
951.677.7755
Tel: 916.564.4442
Tel: 415.43 HELIO (415.434.3546)
Tel: 760.568.5650
951.677.9559
Fax: 916.564.6126
Fax: 415.788.5103
Fax: 877.279.3900