Loading...
07-2622 (RER)P.O. BOX 1504 78-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 Application Number: 407-00002622 1 Property Address: `77511 CALLE ARROBA APN: 774-155-022-2 -000000- Application description: REMODEL - RESIDENTIAL Property Zoning: COVE' RESIDENTIAL Application valuation: 156657 T44t 4 XP Q" Applicant: Architect or Engineer: 13I BUILDING & SAFETY DEPARTMENT BUILDING PERMIT LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professionals Code, and my License is in full force and effect. License Class: License No.: Date: Contractor: OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the following reason (Sec. 7031 .5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars 1$500).: (_ 1 I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). 1 _ 1 I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). (_ 1 I am exempt under Sec. , B.&P.C. for this reason rf /! ate: ��l��lU Owner CONSTRUCTION LE NDI G AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Name: Lender's Address: 0 i LQPEFM1IT Owner: HUNTER WALTER CLEVE *NOT ON FILE UNKNOWN, CA 99999 Other struct info Contractor: Owner DITION VOICE (760) 777-1012 FAX (760) 777-7011 INSPECTIONS (760) 777-7153 C D 005- 1-&q �ry0'e Date: 1/17/08 --------------------------------7-- ---- WORKER'S COMPENSATION DECLARATION ` I hereby affirm under penalty of perjury one of the following declarations: I have and will maintain a certificate of consent to self -insure for workers' compensation, /provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. _ I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier .00 Policy Number - - - - - - - - - - - - - - - I certify that, in the performance of the work for which this permit is issued, I shall not employ any person in,any manner so as to become subject to the workers' compensation laws.of California, and agree that, if I should become subject to the workers' compensation provisions of Section �1 3700 of the L r Cod I shall fo ith comp) ith tho provi //C lic 1 WARNING: FAIL RE 00'TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000) IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the conditions and restrictions set forth on this application. 1 . Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application, the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify th t I have read this application and state that the above information is correct. I agree to comply with all city a county ordinances d state laws relating to building construction, and hereby authorize representatives of s county to enter the above-mentioned prop= tor insg tion poses. Date ignature (Applicant or Agent): Application Number . . . . 07-00002622 Permit . . . BUILDING PERMIT Additional desc . Permit Fee . . . . 839.00 Plan Check Fee 545.35 Issue Date . . . . Valuation . . . . 156657 Expiration Date 7/15/08 Qty Unit Charge Per Extension BASE FEE 639.50 57.00 ---------------------------------------------------------------------------- 3.5000 THOU BLDG 100,001-500,000 199.50 Permit . . . ELECT - ADD/ALT/REM Additional desc . Permit Fee . . . . 110.27 Plan Check Fee 27.57 Issue Date . . . . Valuation . . . . 0 Expiration Date 7/15/08 Qty Unit Charge Per Extension BASE FEE 15.00 2722.00 ----------------------------------- .0350 ELEC ----------------------------------------- NEW RES - 1 OR 2 FAMILY 95.27 Permit . . MECHANICAL Additional desc . Permit Fee . . . . 83.50 Plan Check Fee'. 20.88 Issue Date . . . . Valuation 0 Expiration Date 7/15/08 Qty Unit Charge Per Extension BASE FEE 15.00 2.00 9.0000 EA MECH FURNACE <=100K 18.00 2.00 9.0000 EA MECH B/C <=3HP/100K BTU 18.00 4.00 6.5000 EA MECH VENT FAN 26.00 1.00 ---------------------------------------------------------------------------- 6.5000 EA MECH EXHAUST HOOD 6.50 Permit . . . PLUMBING Additional desc . Permit Fee . . . . 99.00 Plan Check Fee 24.75 Issue Date . . . Valuation . . . . 0 Expiration Date 7/15/08 Qty Unit Charge Per Extension BASE FEE 15.00 10.00 6.0000 EA PLB FIXTURE - 60.00 1.00 7.5000 EA PLB WATER HEATER/VENT 7.50 1.00 3.0000 EA PLB WATER INST/ALT/REP 3.00 LQPERDIIT Application Number 07-00002622 Permit . . . . . . PLUMBING Qty Unit Charge Per Extension • 1.00 9.0000 EA PLB LAWN SPRINKLER SYSTEM 9.00 6.00 .7500 EA PLB GAS PIPE >=5 4.50' ---------------------------------------------------------------------------- Special Notes and Comments EXISTING HOME 1438 SQ. FT. DEMO 1366 SQ.. FT. NEW HOME WILL BE 2722 SQ. FT. WITH EXISTING GARAGE OF 425 SQ. FT. ---------------------------------------------------------------------------- Other Fees . . . . . . ENERGY REVIEW FEE 54.54 STRONG MOTION (SMI) - RES 15.66 Fee summary Charged ----------------- ---------- Paid ---- - ----- ---------- Credited ---------- Due Permit Fee Total 1131.77 .00 .00 1131.77 Plan Check Total 618.55 .00 .00, 618.55 Other Fee Total •70.20 .00 .00 70.20 Grand Total 1820.52 ..00 .00 1820.52 11 7? --r-1.1 .. CITY OF LA QUINTA BUILDING & SAFETY DEPT. APPROVED . FOR CONSTRUCTION DATE 3 e', z3zo cAc v YR a ap ew tkpi / 'li6 cow, 4w'* -rb rel Etcs7lMj CoLoi�, a' (.I IZ- PAtu W(Z Nt; s (litFA Z2. Cz-) At. w I Z x Zx e New o/o / 4xo zT>�— 0 s 3CI q® ;o Cdr 0 ■ CITY OF LA QUINTA BUILDING & SAFETY DEPT. /APPROVE® FOR CONSTRUCTION DATE By &7rsj7ilq Zo q��srb r 7 ►, -G(,a- Ar- A - 0,6A- J, - s 3CI q® ;o Cdr 0 ■ CITY OF LA QUINTA BUILDING & SAFETY DEPT. /APPROVE® FOR CONSTRUCTION DATE By &7rsj7ilq Zo q��srb r 7 ►, -G(,a- Ar- A - 0,6A- Bit, # of La Quinta P SEP 2 8 20PZ unding & Safety Division �.0. 1504, 78-495 Calle Tampico La Quint , CA 92253 - (760) 777-7012 By— �kdi tg -ermi Application and Tracking Sheet Permit # a- �-- Project Address:77%Owner's Name: A. P. Number: ... % Q Address- Legal Description: City, ST, Zip: Contractor:Telephone:Xi A Address: ? Project Descriptio City, ST, Zip: L.A 6?VN)r.4,qgoeo Iv t OKE Telephone: :r s� State Lic. # : City Lic. #:Mai65� Arch., Engr., Designer: /) Address: City, ST, Zip: Telephone: 6 State Lic. #: _ f `� " Construction Type: Y Occupancy: Project type (circle one): New Add'n Alter Repair Demo Name of Contact Person:G Sq. Ft.: f 2 # Stories: # Units: , Telephone # of Contact Person: a 2 Estimated Value of Project: O- APPLICANT:* DO NOT WRITE BELOW THIS LINE #. Submittal Req'd Rec'd TRACKING PERMIT FEES Plan Sets �%/ Plan Check submitted // 9!� Item Amount Structural Cala. Reviewed, ready for correctionsO Plan Check Deposit Truss Calcs. 2 Called Contact Person Plan Check Balance Energy Calcs. ?/ Plans picked up i Construction Flood plain plan Plans resubmitted Mechanical Grading plan 2"" Review, ready for corrections/issue Electrical Subcontactor List Called Contact Person Plumbing Grant'Deed Plans picked up S.M.I. H.O.A.Approval Plans resubmitted Grading IN HOUSE:- ''" Review, ready for corrections/issue Developer Impact Fee Planning Approval Called Contact Person A.I.P.P. Pub. Wks. Appr Date of permit issue School Fees Total Permit Fees SCOTT MORRISON & ASSOCIATES P.O. Box 55329 Riverside, CA 92517 (909)624-1665 ASBESTOS SURVEY REPORT Completed On , May 15, 2006 PLM0511#0601 Client: ,Catherine Hunter 77-511 Calle Arroba La Quinta, CA Project: 77-511 Calle Arroba La Quinta, CA (partial remodel) 31855 Date Palm Drive, Ste. #3-507 Cathedral City, CA 92234 (760)323-7743 On May 11, 2006 an asbestos inspection and bulk sampling was conducted at the above project address. Bulk samples were taken of all suspect asbestos containing building materials (ACBM) from the areas to be remodeled only at the request of the client named above. Bulk samples were submitted to Carolina Environmental, Inc. located at: 107 New Edition Court in Cary, NC (NVLAP Code 101768-0 and Cal. Environ. Lab. Cert. #2483) to estimate the percentage of asbestos by volume and determine the type(s) present . Carolina Environmental, Inc. determines percentages and type of asbestos by using EPA approved method 600/M4-82-020: Interim Method for the Determination of Asbestos in Bulk Samples. Bulk samples are analyzed by PLM (Polarized Light Microscopy). Asbestos is quantified by using the visual arena estimation technique and can only determine the approximate percentage of asbestos present. After a thorough search is conducted and no asbestosis detected"none detected" will be noted in the report. The essence of polarized light microscopy is not to emphatically determine that no asbestos is present, merely that none was detected or, if it was, it was likely to be less than 1.0% of the sample. When findings reveal less than or close to 1.0% asbestos contained in a sample, further analysis may be called for on additional samples to confirm or denounce the initial findings. The California Code of Regulations (CCR 1529) requires bulk sampling be conducted according to the A.H.E.R.A. protocol provisions of 40 CFR Part 763.86. The A.H.E.R.A. protocol recommends three (3) or more friable surfacing samples from a homogeneous area be collected and analyzed before any building material is determined to be non -asbestos containing. Scott Morrison & Associates conducts asbestos inspection surveys following the A. H. E. R.A. inspection protocol. ASBESTOS INSPECTION BY: Scott C. Morrison, DOSH #92-0248 BULK SAMPLES ANALYZED BY: Carolina Environmentait lnc., NVLAP #101768-0 The results on the following page(s) indicate that asbestos was detected in 01 of the 06 samples analyzed. (1) P.O. Box 55329 Riverside, CA 92517 (909)624-1665 INVOICE SCOTT MORRISON & ASSOCIATES 31855 Date Palm Drive, Ste. #3-507 Cathedral City, CA 92234 (760)323-7743 Client: Catherine Hunter 77-511 Calle Arroba La Quinta, CA Project: 77-511 Calle Arroba La Quinta, CA (partial remodel) Inspection date: May 11, 2006 Date: May 15, 2006 Project/ P.O# File name: PLM0511#0601 asbestos inspection/ bulk sampling (single-family home) _ $160.00 06 total bulk samples for analysis (PLM) @ $20.00 each = $120.00 # hours of travel time @ $ per hour = included Total amount due = $280.00 Please send payment to: 31-855 Date Palm Drive, Ste.#3-507 Cathedral City, CA 92234 <sY Terms: Due upon receipt. Original report upon payment. Thank you. P SCOTT MORRISON & ASSOCIATES P.O. Box 55329 31855 Date Palm Drive, Ste. #3-507 Riverside, CA 92517 Cathedral City, CA 92234 (909)624-1665 (760)323-7743 PLM0511 #0601 Sample #CH -1 Type of material: drywall Location: interior E. wall, living room Area:throughout interior walls Friable:no Results: none detected Sample #CH -2 Type of material: drywall Location: interior W. wall, master bedroom Area:throughout interior walls Friable:no Results: none detected Sample #CH -3 Type of material: drywall Location: interior S. wall, master bedroom bathroom Area: throughout interior walls Friable:no Results: none detected Sample #CH -4 Type of material: 12" floor tile/ green Location: bathroom floor Area: approx. 15 sq. ft. Friable:no Results: 3% Chrysotile asbestos Sample #CH -5 Type of material:tile mastic/ yellow Location:under sample #CH -4 Area:approx. 15 sq. ft. Friable:no Results:none detected Sample #CH -6 Type of material: exterior wall stucco/ It. green -grey Location: exterior NE wall Area:throughout exterior walls Friable:no Results: none detected Note: Alf asbestos containing building material(s) containing greater than 1.0% asbestos by volume or weight, must be removed by a state certified asbestos abatement contractor prior to any demolition or renovation of the property. Inspector (V " xi. Scott C. Morrison Certified Asbestos Consultant DOSH#92-0248 (2) A Date 2/12/08 No. 29912 Owner Hunter Address 77 -511 -Calle Arroba City La Quinta Zip Tract # Type Residential Addition Lot # No. Street Unit 1 77511 Calle Arroba Unit 2 Unit 3 Unit 4 ` Unit 5 CERTIFICATE OF COMPLIANCE Desert Sands Unified School District 47950 Dune Palms Road La Quinta, CA 92253 (760) 771-8515 APN # Jurisdiction Permit # No. of Units S.F. Lot # No 395 Unit 6 Unit 7 Unit 8 Unit 9 Unit 10 4����F1EDsc�o Q BERMUDA DUNES r 04) RANCHO MIRAGE INDIAN WELLS d� PALM DESERT y LA QUINTA 1QINDIO y(1 O J 774-155-022 La Quinta 1 Street '-AJ Comments Originally pd for 961sf on 12/20/06, cert #29105 (revised copy attached). Demo'd 1,366 sf & rebuilding to total 2,722sf. (961sf + 395sf=1,356sf. 1356sf + 1366sf = 2,722sf) At the present time, the Desert Sands Unified School District does not collect fees on garages/carports, covered patiostwalkways, residential additions under 5 00 square feet, detached accessory structures (spaces that do not contain facilities for Irving, sleeping, cooking, eating or sanitation) or replacement mobile ho mes. It has been determined that the above-named owner is exempt from paying school fees at this time due to the following reason: EXEMPTION NOT APPLICABLE This certifies that school facility fees imposed pursuant to Education Code Section 17620 and Government Code 65995 Et Seq. in the amount of $2.63 X 395 S.F. or $1,038.85 have been paid for the property listed above and that building permits and/or Certificates of Occupancy for this square footage in this proposed project may now be issued. Fees Paid By OC/Wells Fargo - Walter Hunter Check No. 0009702943 Name on the check Telephone 912.8431 Funding Residential By Dr. Sharon P. McGehee Superintendent Fee collected /exempted by Sh ron McGilvrey Payment Recd `= $0.00 $1,038.85 ,•Over/Under, Signature NOTICE: Pursuant to Government Code Section 66020(d)(/this this will serve to notify you that the 90 -day approval period in which you may protest the fees o r other payment identified above will begin to run from the date on which the building or installation permit for this project is issued, or from the date on which those amounts are paid to the District(s) or to another public entity authorized to collect them on the District('s) behalf, whichever is earlier. NOTICE: This Document NOT VALID without embossed seal Embossed Original - Building Department Applicant Copy - Applicant/Receipt Copy - Accounting TITLE 24 REPORT Title 24 Report for: The Hunter Residence 77511 Calle Arroba La Q u i nta, CA 92253 Project Designer: Beach Design, Inc. 45138 E. Florida AVenue Hemet, CA 92544 (951) 927-8083 Report Prepared By• DL Richart Beach Design, Inc. C 45138 E. Florida Ave. Hemet, CA 92544 (951) 927-8083 Job Number: Hunter -07 Date: 11/1/2007 CITY OF LA QUINT BUILDING & SAFETYVd APPROVE FOR CONSTRUCT DA Nm 9 M 0 T M I NOV 2 0 2007 The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2005 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC - www.energysoft.com. EnergyPro 4.4 by EnergySoft Job Number: Hunter -07 User Number: 6922 I TABLE OF CONTENTS I Cover Page Table of Contents Form CF -1 R Certificate of Compliance Form MF -1 R Mandatory Measures Summary Form WS -5R Residential Kitchen Lighting HVAC System Heating and Cooling Loads Summary Room Heating Peak Loads Room Cooling Peak Loads 9 1 2 3 7 9 10 11 13 EnergyPro 4.4 by EnergySoft Job Number: Hunter -07 User Number: 6922 Certificate Of Compliance : Residential (Part 1 of 4) CF -1 R TheBunteLResidence Existing Floor Area: (N) 0 deg Raised Floor Area: 11/SI2097 Project Title _77.5 I t i nta Volume Units Zone Type Type EVACJ;ystem 9 79� Date Project Address Building Permit # Beach _Desi�gaYlnc (951) 927-8083 Telephone Plan Check/Date Documentation hor BaeL-Dr CL-CA.mateZone_L5 Field Check/Date CompliWKce Method Climate Zone TDV Standard Proposed Compliance AkBtu/sf-yr) Design Design Margin Space Heating 1.92 0.65 1.27 Space Cooling 57.56 58.52 -0.96 Fans 8.10 8.37 -0.27 Domestic Hot Water 9.43 9.28 0.15 Pumps 0.00 0.00 0.00 Totals 77.01 76.83 0.18 Percent better Building Type: FX] Single Family ❑ Multi Family Building Front Orientation: Fuel Type: 0.2% ❑ Addition Total Conditioned Floor Area ❑ Existing + Add/Alt Existing Floor Area: (N) 0 deg Raised Floor Area: Natural Gas Slab on Grade Area: Fenestration:' Average Ceiling Height: Area: 475 ft2 Avg. U: 0.29 Number of Dwelling Units: Ratio: 17.5% - . Avg. SHGC: 0.36 Number of Stories: BUILDING ZONE INFORMATION # of Thermostat Zone Name Floor Area Volume Units Zone Type Type EVACJ;ystem 9 79� 9a 43� X00_ Conditioned _-Setback- OPAQUE SURFACES Insulation Act. Gains Condition 2,722 ft2 n/a ft2 0 ft2 2,722 ft2 9.0 ft 1.00 1 Vent Hgt. Area 2 -n/a Type Frame Area U -Fac. Cay. Cont. Azm. Tilt Y / N Status JA IV Reference Location / Comments Wall- Wood- 1.58_ _0_0Z4_ --R--19-0`-0_0_ 0__9.0 Door None- ___4.0 _0-50.0_ _Clone_ 0`-0.0 0__90 Wall_ vYood_ ---457- -0.074 -R19_ _R_00_ 9.0_ 90 Wall- wood- -226_ _0_074 019_ R_Q_0 -.80_ 9.0 Wall_ Wood_ 69--UL4- R19 R-0_0 -27-0 90 _RooL_.Wood_ x-328_ 0-025.0-3$_ _R-0.0 0_ 0 Wall wnnd ----I$3_ _0.074 Os9_ 0`0_0 -0_ 9.0 Door- None- X8.0_500_ -Clone_ 0•`0 0 0_ 9D Wall- YVnod_ _5.8.0_074 019 -0.0 90- 90 Wall_ Wood _ .144 0..074 R-19 RAO __1_8a___90 WaIL- V1l_ood- 290_ _0.074-R_1.9.0'`0A-2Z0_ 90 .Dnor_ None 1.8_ _05.00 -None_ 0:=0-_ X7.0__9.0 Roof Wood- x.,394 0.025 R-38_ 0_0_ 0_ 0 X X X IX X EX IX X X IX IX [ X O ❑ ❑ ❑ ❑New ❑ ❑ ❑ ❑N.ew ❑ ❑ ❑ ❑ ❑ ❑Naw- ❑Clew ❑Ne.w ❑ ❑ ❑ _0.9=A5 1st-Eloor N.ew 28-A4 1st_FJoor New 0.9_A5 1sLF_loo.r New -0.9- 5 1stFloor 01-A5 1st-Elo_or New 0J_ -A18 1st -8 or New _09=A5 2ndFJoor Kew 28-A4 2nd-Eloor New 09-A5 2ndFJoor Clew _09-A5 2nd-Eloor 09_A5_ 2nd Boor 28=A4 2nd_Eloor _0JA18 2ndEloor Run Initiation Time: 11/01/0710:40:28 Run Code: 1193942428 EnergyPro 4.4 by Energysoft User Number: 6922 Job Number: Hunter -07 Page:3 of 14 Certificate Of Compliance : Residential (Part 2 of 4) CF -1 R The Hunter Residence 11/1/2007 Project Title Date FENESTRATION SURFACES # Type Area U -Factor' SHGC2 True Azm. Tilt Cond. Stat. Glazing Type Location/ Comments -1— -Window Front (N)- 114.0 _0.29.0_NFRC -0-3.6 11FRC 0_ _90_ NewMilgardMn-y.LSC 1.siEloor 2 Window Left (E_ 25.0 0.290 NFRC 0_36 NFRC 90 90 New Milgard Vinyl SC 1st Floor 3 Window Rear (S) 127.0 0.290 NFRC 0_36 NFRC 180 90 New Milgard Vinyl SC 1st Floor 4 Window Front (NL 47.0 0.290 NFRC 0_36 NFRC 0 90 New Milgard Vinyl SC 2nd Floor 5 Window Rear (S) 98.0 0.290 NFRC 0_36 NFRC 180 90 New ward Vinyl SC 2nd Floor 6 Window Right (W)_ 64.0 0.290 NFRC 0_36 NFRC 270 90 New Milgard Vinyl SC 2nd Floor 1. Indicate source either from NFRC or Table 116A. INTERIOR AND EXTERIOR SHADING # Exterior Shade Type SHGC 1 Bug Screen 0.76 2 Bug Screen 0.76 3 Bug Screen 0.76 4 Bug Screen 0.76 5 Bug Screen 0.76 6 Bug Screen 0.76 2. Indicate source either from NFRC or Table 116B. Window Overhang Hgt. Wd. Len. Hgt. LExt. REA Left Fin Right Fin Dist. Len. Hgt. Dist. Len. Hgt. THERMAL MASS FOR HIGH MASS DESIGN Area Thick. Heat Inside Condition Location/ Type (sf) (in.) CaD. Cond. R -Val. JA -IV Reference Status Comments PERIMETER LOSSES Insulation Condition Location/ Type Length R -Val. Location JA IV Reference Status Comments Slab Perimeter 122 None No Insulation 26-A1 New 1st Floor Slab Perimeter 111 None No Insulation 26-A1 New 2nd Floor Run Initiation Time: 1110110710:40:28 Run Code: 1193942428 EnergyPro 4.4 by EnergySoft User Number. 6922 Job Number: Hunter -07 Page:4 of 14 Certificate Of Compliance : Residential (Part 3 of 4) CF -1 R The Hunter Residence 11/1/2007 Project Title Date HVAC SYSTEMS Heating Minimum Cooling Minimum Condition Thermostat Location Type Eff Type Eff Status Type HVAC System Electric 7.70 HSPF Split Air Conditioner 14.5 SEER New Setback HVAC DISTRIBUTION Location Duct Cooling Location HVAC System Ducted Ducted Hydronic Piping Pipe Pipe Insul. System Name Length Diameter Thick. Duct Condition Ducts R -Value Status Tested? 8.0 New No WATER HEATING SYSTEMS Rated Tank Energy Tank Insul. Water Heater # in Input Cap. Condition Factor Standby R -Value System Name Type Distribution Syst. (Btu/hr) (gal) Status or RE Loss (%) Ext. A O Smith ECRT-50 Small Elec. All Pipes Ins 1 40,000 50 New 0.94 n/a n/a Multi -Family Central Water Heating Details Hot Water Pump Hot Water Piping Length (ft) Add 1/2" Control # HP Tvoe In Plenum Outside Buried Insulation COMPLIANCE STATEMENT This certificate of compliance lists the building features and specifications needed to comply with Title 24, Parts 1 and 6 of the California Code of Regulations, and the administrative regulations to implement them.This certificate has been signed by the individual with overall design responsibility. The undersigned recognizes that compliance using duct design, duct sealing, verification of refrigerant charge and TXVs, insulation installation quality, and building envelope sealing require installer testing and certification and field verification by an approved HERS rater. Desigr s or (per Business & Professions Cope) Nam Title/Firm: Beach Design, Inc. Address: 45138 E. Florida AVenue Hemet, CA 92544 n (951) 927-8083 Lic. #: -Q e) (date) Enforcement Agency Name: Title/Firm: Address: Telephone: (signature) (date) Documentation Author Name: DL Richart Title/Firm: Beach Design, Inc. Address: 45138 E. Florida Ave. Hemet, CA 92544 951 927-8083 � Q 1(sle) ( Certificate Of Compliance : Residential (Part 4 of 4) CF -1 R The Hunter Residence 11/1/2007 Project Title Date Special Features and Modeling Assumptions The local enforcement agency should pay special attention to the items specified in this checklist These items require special written justification and documentation, and special verification to be used with the performance approach. The local enforcement agencv determines the adeguacv of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted. Plan Field The DHW System "A O Smith ECRT-50" includes credit for a Solar System with a 60.0% Solar Fraction (see CF -SR). HERS Required Verification Items in this section require field testing and/or verification by a certified home energy rater under the supervision of a' HERS provider using approved testing and/or verification methods. Plan Field The HVAC System "HVAC System" incorporates a HERS verified Refrigerant Charge test or a HERS verified Thermostatic Expansion Valve. This building has credit for Insulation Quality Installation. A certified HERS rater must visually verify the installation of all Insulation. EnergyPro 4.4 by EnergySoft User Number: 6922 Job Number: Hunter -07 Page:6 of 14 1 Mandatory Measures Summary: Residential (Page 1 of 2) MF -1 R NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. More stringent compliance requirements from the Certificate of Compliance supercede the items marked with an asterisk (') below. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. DESCRIPTION Check or initial applicable boxes or check NA if not applicable and included with the permit application documentation. NIA DESIGNER ENFORCE - MENT Building Envelope Measures ❑ ❑X ❑ § 150(a): Minimum R-19 in wood ceiling insulation or equivalent U -factor in metal frame ceiling. ❑ ❑X ❑ § 150(b): Loose fill insulation manufacturer's labeled R -Value: ❑ ❑X ❑ § 150(c): Minimum R-13 wall insulation in wood framed walls or equivalent U -factor in metal frame walls (does not ❑ ❑X ❑ apply to exterior mass walls). Y ❑ ❑ § 150(d): Minimum R-13 raised floor insulation in framed floors or equivalent U -factor. P El ❑ § 150(e): Installation of Fireplaces, Decorative Gas Appliances and Gas Logs. ❑ ❑X ❑ 1. Masonry and factory -built fireplaces have: ❑ ❑X ❑ a. closable metal or glass door covering the entire opening of the firebox ��{1I El El b. outside air intake with damper and control, flue damper and control 159 � ❑ ❑ 2. No continuous burning gas pilot lights allowed. Y ❑ ❑ § 150(f): Air retarding wrap installed to comply with §151 meets requirements specified in the ACM Residential Manual. [A ❑ ❑ § 150(g): Vapor barriers mandatory in Climate Zones 14 and 16 only. VN ❑ ❑ § 150(1): Slab edge insulation - water absorption rate for the insulation alone without facings no greater than 0.3%, water vapor ❑ ❑ permeance rate no greater than 2.0 punch. ❑ ❑X ❑ § 118: Insulation specified or installed meets insulation installation quality standards. Indicate type and include ❑ ❑X ❑ CF -6R Form: ❑ ❑X ❑ § 116-17: Fenestration Products, Exterior Doors, and Infiltration/Exfiltration Controls. 1. Doors and windows between conditioned and unconditioned spaces designed to limit air leakage. ❑ ❑X ❑ 2. Fenestration products (except field fabricated) have label with certified U -Factor, certified Solar Heat Gain ❑ ❑X ❑ Coefficient (SHGC), and infiltration certification. 3. Exterior doors and windows weatherstripped; all joints and penetrations caulked and sealed. ❑ IR ❑ Space Conditioning, Water Heating and Plumbing System Measures § 110-13: HVAC equipment, water heaters, showerheads and faucets certified by the Energy Commission. ❑ Q ❑ § 150(h): Heating and/or cooling loads calculated in accordance with ASHRAE, SMACNA or ACCA. ❑ ❑X ❑ § 150(i): Setback thermostat on all applicable heating and/or cooling systems. ❑ ❑X ❑ § 1500): Water system pipe and tank insulation and cooling systems line insulation. 1. Storage gas water heaters rated with an Energy Factor less than 0.58 must be externally wrapped with insulation ❑ ❑ having an installed thermal resistance of R-12 or greater. 2. Back-up tanks for solar systems, unfired storage tanks, or other indirect hot water tanks have R-12 external ❑ ❑ insulation or R-16 internal insulation and indicated on the exterior of the tank showing the R -value. 3. The following piping is insulated according to Table 150-A/B or Equation 150-A Insulation Thickness: 1. First 5 feet of hot and cold water pipes closest to water heater tank, non -recirculating systems, and entire ❑ ❑X ❑ length of recirculating sections of hot water pipes shall be insulated to Table 150B. 2. Cooling system piping (suction, chilled water, or brine lines), piping insulated between heating source and ❑ ❑X ❑ indirect hot water tank shall be insulated to Table 150-B and Equation 150-A. 4. Steam hydronic heating systems or hot water systems > 15 psi, meet requirements of Table 123-A. FX ❑ ❑ 5. Insulation must be protected from damage, including that due to sunlight, moisture, equipment maintenance, ❑ ❑X ❑ and wind. 6. Insulation for chilled water piping and refrigerant suction piping includes a vapor retardant or is enclosed ❑ ❑ entirely in conditioned space. 7. Solar water -heating systems/collectors are certfiied by the Solar Rating and Certificabon Corporation. ❑ ❑ EnergyPro 4.4 by EnergySoft User Number. 6922 Job Number: Hunter -07 Page:7 of 14 Mandatory Measures Summary: Residential (Page 2 of 2) MF -1 R NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. More stringent compliance requirements from the Certificate of Compliance supercede the items marked with an asterisk (') below. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. DESCRIPTION Instructions: Check or initial applicable boxes when completed or check NIA if not ENFORCE- annlirahia_ N/A DESIGNER MENT Space Conditioning, Water Heating and Plumbing System Measures: (continued) § 150(m): Ducts and Fans 1. All ducts and plenums installed, sealed and insulated to meet the requirements of the CMC Sections 601, 602, 603, 604, ❑ ❑x ❑ 605, and Standard 6-5; supply -air and retum-air ducts and plenums are insulated to a minumum installed level of R-4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct -closure system that meets the applicable requirements of UL 181, UL 181 A, or UL 181 B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings greater than 1/4 inch, the combination of mastic and either mesh or tape shall be used. 2. Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed ❑ sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area of the ducts. 3. Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive ❑ duct tapes unless such tape is used in combination with mastic and draw bands. 4. Exhaust fan systems have back draft or automatic dampers. ❑ 5. Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operating dampers. 6. Protection of Insulation. Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that can cause degradation of the material. 7. Flexible ducts cannot have porous inner cores. § 114: Pool and Spa Heating Systems and Equipment 1. A thermal efficiency that complies with the Appliance Efficiency Regulations, on-off switch mounted outside of the heater, weatherproof operating instructions, no electric resistance heating and no pilot light. 2. System is installed with: a. At least 36" of pipe between finer and heater for future solar heating. b. Cover for outdoor pools or outdoor spas. 3. Pool system has directional inlets and a circulation pump time switch. § 115: Gas fired fan -type central furnaces, pool heaters, spa heaters or household cooking appliances have no continuously burning pilot light. (Exception: Non -electrical cooking appliances with pilot < 150 Btu/hr) § 118 (i): Cool Roof material meets specified criteria Lighting Measures § 150(k)1: HIGH EFFICACY LUMINAIRES OTHER THAN OUTDOOR HID: contain only high efficacy lamps as outlined in Table 150-C, and do not contain a medium screw base socket (E241E26). Ballasts for lamps 13 Watts or greater are electric and have an output frequency no less than 20 kHz. § 150(k)1: HIGH EFFICACY LUMINAIRES - OUTDOOR HID: contain only high efficacy lamps as outlined in Table 150-C, luminaire has factory installed HID ballast. § 150(k)2: Permanently installed luminaires in kitchens shall be high efficacy luminaires. Up to 50% of the Wattage, as determined in Section 130(c), of permanently installed luminaires in kitchens may be in luminaires that are not high efficacy luminaires, provided that these luminaires are controlled by switches separate from those controlling the high efficacy luminaires. § 150(k)3: Permanently installed luminaires in bathrooms, garages, laundry rooms, utility rooms shall be high efficacy luminaires. OR are controlled by an occupant sensor(s) certfied to comply with Section 119(d). § 150(k)4: Permanently installed luminaires located other than in kitchens, bathrooms, garages, laundry rooms, and utility rooms shall be high efficacy luminaires (except closets less than 70 ft) OR are controlled by a dimmer switch OR are controlled by an occupant sensor that complies with Section 119(d) that does not tum on automatically or have an always on option. § 150(k)5: Luminaires that are recessed into insulated ceilings are approved for zero clearance insulation cover (IC) and are certified to ASTM E283 and labeled as air tight (AT) to less than 2.0 CFM at 75 Pascals. § 150(k)6: Luminaires providing outdoor lighting and permanently mounted to a residential building or to other buildings on the same lot shall be high efficacy luminaires (not including lighting around swimming pools/water features or other Article 680 locations) OR are controlled by occupant sensors with integral photo control certified to comply with Section 119(d). § 150(k)7: Lighting for parking lots for 8 or more vehicles shall have lighting that complies with Sections 130, 132, and 147. Lighting for parking garages for 8 or more vehicles shall have lighting that complies with Section 130, 131, and 146. ❑x C ❑X ❑ ❑ ❑ R1 El Elf 19 ❑ ❑ ❑ ❑X ❑ ❑ ❑ i ❑■ A ❑ ❑ § 150(k)8: Permanently installed lighting in the enclosed, non -dwelling spaces of low-rise residential buildings with four or more ® ❑ ❑ dwelling units shall be high efficacy luminaires OR are controlled by occupant sensor(s) certified to comply with Section 119(d). EnergyPro 4.4 by EnergySoft User Number. 6922 Job Number. Hunter -07 Page:8 of 14 Residential Kitchen Lighting Worksheet WS -5R The Hunter Residence 11/1/2007 Project Title Date At least 50% of the total rated wattage of permanently installed luminaires in kitchens must be in luminaires that are high efficacy luminaires as defined in Table 150-0. Luminaires that are not high efficacy must be switched separately. Kitchen Lighting Schedule. Provide the following information for all luminalres.to be installed in kitchens. Luminaire Type High Efficacy? Watts High Efficacy Quantity Watts Other Watts (1) 26w Compact Fluorescent Quad 2 Pin Yes X1 No 37.0 x 6 = 222 or U 26w Compact Fluorescent Quad 2 Pin Yes X I No 1 74.0 x 2 = 148 or 60w Surface Mount Incandescent Yes I No IX 60.0 x 1 = or 60 Yes No x = or Yes No x = or Yes No x = or Yes No I x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No X. = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Total A: 370 B: 60 COMPLIES IF Az B YES Gil NO ❑ EnergyPro 4.4 by EnergySoft User Number: 6922 Job Number: Hunter -07 Page:9 of 14 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME DATE The Hunter Residence 11/1/2007 SYSTEM NAME FLOOR AREA HVAC System 2,722 NGINEERING CHECKS SYSTEM LOAD Number of Systems I1 Heating System Output per System 29,600 Total Output (Btuh) 29,600 Output (Stuh/sgft) 10.9 Cooling System Output per System 29,600 Total Output (Btuh) 29,600 Total Output (Tons) 2.5 Total Output (Btuh/sgft) 10.9 Total Output (sgft/Ton) 1,103.5 Air System CFM per System 800 Airflow (cfm) 800 Airflow (cfm/sgft) 0.29 Airflow (cf nfTon) 324.3 Outside Air (%) 0.0 Outside Air (cfm/sgft) 0.00 Note: values above given at ARI conditions Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAK COIL HTG. PEAK CFM ISensiblel Latent I CFM I Sensible 1,516 30,278 3,688 1,093 31,912 0 4,709 3,495 0 0 0 0 0 0 0 744 -744 4,709 3,495 40,439 3,688 38158 Rheem RCFL-A 3621B 26,139 0 29,600 Total Adjusted System Output26,139 0 29,600 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK Aug 2 pm Jan 12 am EATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heatin Peak 26.0 of 65.9 of 100.7 of 101.5 of O Supply Air Ducts Outside Air 0 cfm Heating Coil Supply Fan 97.4 of 800 cfm ROOMS 65.9 of 70.0 of Return Air Ducts `S DOLING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Cooling Peak 111.0/77.60F 83.5/64.30F 52.8/51.30F 53.7 / 51.7 OF I O Supply Air Ducts Outside Air 0 cfm/ Cooling Coil Supply Fan 59.2 / 54.0 of 800 elm 41.9% R.H. ROOMS 83.5/64.3 OF 78.0 / 62.5 of Ile Return Air Ducts I EnergyPro 4.4 by EnergySoft User Number: 6922 Job Number: Hunter -07 Page: 10 of 14 ROOM HEATING PEAK LOADS Project Title Date The Hunter Residence 11/1/2007 Room Information Desicin Conditions Room Name 1st Floor Time of Peak Jan 12 am Floor Area 1,328 Outdoor Dry Bulb Temperature 26OF Indoor Dry Bulb Temperature 70 OF C, Conduction Area U -Value AT of Btu/hr Door perimeter =121.5 X x X X x X X x X x x X X x X X X X X x X x X X X X X X x x x X X x X X X x X 0.7300 x X X X X x X X X x X X X X x X X X x x x x x x X x X x x x x X X X x X x X x 44 = = = = = = = = = = = = = = = = = = 3,903 158.0 0.0740 44 514 114.0 0.2900 44 1,455 40.0 0.5000 44 880 457.0 0.0740 44 1,488 25.0 0.2900 44 319 225.5 0.0740 44 734 127.0 0.2900 44 1,621 69.0 0. 74 44 225 1,328.0 0.0250 44 1.461 items snown with an asterisk (-r) denote conduction tnrougn an intenor surface to another room. Page Total: 12,599 Infiltration: 1.00 1 x 1.064 x 1 328 x 10.00 x 0.403 / 6] x AT = 4176 chedule Jr Sensible Area Ceiling Height ACH AT Fraction TOTAL HOURLY HEAT LOSS FOR ROOM 16,775 EnergyPro 4.4 by EnergySoft User Number: 6922 Job Number: Hunter -07 Page: 11 of 14 ROOM HEATING PEAK LOADS Project Title The Hunter Residence Date 11/1/2007 Room Information Desicin Conditions Room Name 2nd Floor Time of Peak Jan 12 am Floor Area 1,394 Outdoor Dry Bulb Temperature 26 of Indoor Dry Bulb Temperature 70 OF 0.7300 Conduction Wood Door Area X X X x X X X X X x X X X X X X X X X X X X X x X x X x X X X X X x X X. x X x U -Value x X X x X X X X x X x X X X X X X X X x, x x X X X X X X x X X X X X X X X X X AT of = = = = = = = = = = = = = = = = = = = Btu/hr perimeter = 111.0 0.7300 44 3,565 183.0 0.0740 44 596 47.0 0.2900 44 600 18.0 0.5000 44 396 57.5 0.0740 44 187 144.0 0.0740 44 469 98.0 0.2900 44 1250 290.0 0.0740 44 944 0 0.2900 44 817 18.0 0.5000 44 396 1394.0 0.0250 44 33 Items shown with an asterisk ('f) denote conduction through an interior surface to another room. Page Total: 10 754 Infiltration: 1.001X 1.064 x 1 394 x 8.00 x 0.504 / 6] x � = 4 383 chedule Jr Sensible Area Ceiling Height ACH OT Fraction TOTAL HOURLY HEAT LOSS FOR ROOM 15,137 EnergyPro 4.4 by EnergySoft User Number: 6922 . Job Number: Hunter -07 Page: 12 of 14 RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Title Date The Hunter Residence 11/1/2007 Room Information Design Conditions Room Name: 1st Floor Outdoor Dry Bulb Temperature: 1120E Floor Area: 1,328 sf Outdoor Web Bulb Temperature: 780E Indoor Dry Bulb Temperature: 78OFOutdoor Daily Range: 340F opaque surraces R-19 Wall Wood Door R-19 Wall R-19 Wall R-19 Wall R-38 Roof Attic Orientation Area X X X X X X x x x x x x U -Factor X X X X X X x x x x x x CLTD 1 N 158.0 0.0740 23.0 N 40.0 0.5000 23.0 E 457.0 0.0740 33.0 S 225.5 0.0740 26.0 1,013 69.0 0.0740 33.0 N 1,328.01 0.0250 56.0 Items shown with an asterisk (`) denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Fenestration Nage I otal Btu/hr 269 460 1,116 434 168 1,859 4 306 Orientation Btu/hr Shaded Area x X x X X X X X x GLF + + + + + + + + + Unshaded Area X X X X X X X X x GLF = Btu/hr N 0.0 19.2 114.0 19.2 2,184 E 0.0x 19.2+ 25.0X 40.5= 1,013 S 0.0x 19.2+ 127.0X 19.2= 2,444 Page Total 5641 Internal Gain Btu/hr Occu ants F4 Occupants X 230 Btuh/occ. = 920 E ui ment Dwelling Units X 1,6001 Btuh = 1,600 Infiltration: 1.064 x 0.87 x 93.70 x 0 = 2 936 Air Sensible CFM ELA Z�'T TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 15,4041 Latent Gain Btu/hr Occu ants F___41 Occupants x 1 200 Btuh/occ. = 800 Infiltration: 4,771 x 0.87 x 93.70 x 0.00263 = 1019 Air Latent CFM ELA pW TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 1,819 EnergyPro 4.4 by EnergySoft User Number: 6922 Job Number: Hunter -07 Page: 13 of 14 K RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Title Date The Hunter Residence 11/1/2007 Room Information Desi n Conditions Room Name: 2nd Floor Outdoor Dry Bulb Temperature: 1120E Floor Area: 1,394 sf Outdoor Web Bulb Temperature: 78oF Indoor Dry Bulb Temperature: 78OFOutdoor Daily Range: 340F Opaque 5urraces R-19 Wall Wood Door R-19 Wall R-19 Wall R-19 Wall Wood Door R-38 Roof Attic Orientation Area X X X X X X X X X X X X U -Factor X X X X X X X X X X X X CLTD 1 (N) 183.0 0.0740 23.0 N 18.0 0.5000 23.0 E 57.5 0.0740 33.0 S 144.0 0.0740 26.0 1,886 290.0 0.0740 33.0 64.0 18.0 0.5000 33.0 (N) 1,394.0 0.0250 56.0 Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Fenestration Internal Gain rage 1 otal Btu/hr 311 207 140 277 708 297 1,952 3 893 Orientation Shaded Area X x x X X x X X X X GLF + + + + + + + + + + Unshaded Area X x x x X x X X X X Page GLF = = - = = = = - = = Btu/hr N 0.0 19.2 47.0 19.2 900 S 0.0x 19.2+ 98.0X 19.2= 1,886 0.0 19.2 64.0 40.5 2,594 5 380 Total Btu/hr Occupants Occupants X 230 Btuh/ocC. = 920 E ui rent 1 Dwelling Units x 1 600 Btuh = 1,6001 Infiltration: 1.064 X 0.87 X 98.36 X = 3.0A'>1 Air Sensible CFM ELA DT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 14,875 Latent Gain Btu/hr occupants Occupants x 200 Btuh/oCC. = 800 Infiltration: 4,771 .x 0.87 x 98.36 x 0.00263 = 1069 Air Latent CFM ELA .&W l TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 1,869 4 EnergyPro 4.4 by EnergySoft User Number. 6922 Job Number: Hunter -07 Page: 14 of 14