12-0196 (SOL)P.O. BOX 1504 4 78-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 BUILDING & SAFETY DEPARTMENT BUILDING PERMIT Application Number: 12-00000196 _ Owner: Property Address:' -77849 CALLE ARROBA HARTMAN SANDRA APN: 774-172=013-2 -000000- 77849 CALLE ARROBA Application description: SOLAR LA QUINTA, CA 92253 Property Zoning: COVE RESIDENTIAL Application valuation: 40000 Contractor: Applicant: Architect or Engineer: SOLARCITY CORPORATION 2896 METROPOLITAN PLACE POMONA, CA 91767 (650)28 No.: 8 LiC. No.: 888104 VOICE (760) 777-7012 FAX (760) 777-7011 INSPECTIONS (760) 777-7153 Date: 5/22/12 ------------------------------------------------------------------------------------------------- LICENSED CONTRACTOR'S DECLARATION WORKER'S COMPENSATION DECLARATION I hereby affirm. under penalty of perjury th�1-nnsed underprovisions of Chapter 9 (commencing with I hereby affirm under penalty of perjury one of the following declarations: Section 7000) of Division 3 of the Businessionals Code, and my License is in full force and effect. - _ I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided License Class: B C10 C20 License No.: 888104 for by Section 3700 of the Labor Code, for the performance of the work for which this permit is �^ h - issued. Date. ' O / G6ontract _ I have and will maintain workers' compensation insurance, -as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation OWNER -BUILDER DECLARATION insurance carrier and policy number are: I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the Carrier ZURICH AMERICAN Policy Number WC967346703 following reason ISec. 7031 .5, Business and Professions Code: Any city or county that requires a permit to _ I certify that, in the performance of the work for which this permit is issued, I shall not employ any construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the person in any manner so as to become subject to the workers' compensation laws of California, permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State and agree that, if I sh uld bec a subject to the workers' compensation provisions of Section License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or 3700 of the Labor C , I shall fo hwith co StAI h those provisions. that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by ��JJ2Q any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($5001: Date:F"/0pplicant: (_ 1 1, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). 1 _ 1 I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). (_ ) I am exempt under Sec. , B.&P.C. for this reason Date: Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Name: Lender's Address: LQPERMIT WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,0001. IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the conditions and restrictions set forth on this application. 1. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application, the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents and employees for any act or omission related to the work being performed under or following issuance of this permit. . 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the abgue-infamation is correct. I agree to comply with all city and county ordinances and state laws relating to buildiV constru 'on, and hereby authorize representatives of thiscountyto enter upon the above-mentioned operty or or purposes. Date% 'ZA3�26ignature (Applicant or Agent . 1� R LQPERMIT Application Number . . . . . 12-00000196 Permit . . . SOLAR PERMIT Additional desc . Permit Fee . . . . 22.50 Plan Check Fee 5.63 Issue Date . . . . 5/23/12 Valuation . . . . 40000 Expiration Date 11/19/12 Qty Unit Charge Per Extension BASE FEE 15.00 1.00 4.5000 EA SOLAR COLLECTOR < 1000 4.50 1.00 3.0000 ---------------------------------------------------------------------------- EA SOLAR EQUIP MISCELLANEOUS 3.00 Permit . . . ELEC-MISCELLANEOUS,. Additional desc . Permit Fee . . . . 30.00 Plan Check Fee 7.50 Issue Date . . . . 5/23/12 Valuation . . . . 0 Expiration Date 11/19/12 Qty Unit Charge Per Extension BASE FEE 15.00 2.00 7.5000 EA ELEC PWR APP >1 TO <=10 15.00 -----------------------'----------------------------------------------------- Special Notes and Comments 10.8kW SOLAR ARRAY - (46) 235W.YINGLI PANELS W/ (1) PVI -4.2 AND (1) PVI -6000 POWER ONE•AURORA INVERTERS [782SF]"THIS PERMIT INCLUDES 225AMP SERVICE UPGRADE. 2010 CALIFORNIA ELECTRICAL CODE. May 22, 2012 4:43:25 PM AORTEGA ---------------------------------------------------------------------------- Other Fees . . . . . . . . . BLDG STDS ADMIN (SB1473) 2.00 Fee summary Charged Paid Credited ---------- Due --------------------------- Permit Fee Total -------------------- 52.50 52.50 .00 .00 Plan Check Total 13.13 13.13 .00 .00 Other Fee Total 2.00 2.00 .00 .00 Grand Total 67.63 67.63 .00 .00 Bin# 1� I�-t Pemlit # Project Address: -1 -7 A. P. Number: Legal Description: Contractor. Address:3 City, ST, Zip:e<)Jn Telephone: � .e�� State Lia # Arch.. EW., Designer. Address: City, ST, Zip: Telephone: State Lie. #: Name of Contact Person: Telephone # of Contact F # Submittal Pian Sets Structural Calm Truss Cala. 'Litte 24 Cales. Flood plain plan Grading plan Subcoataetor List Grant Deed H.O.A. Approval IN HOUSE: - Planning Approval Pub. Wks. Appr School Fees City of La Quinta Building & Safety Division P.O. Box 1504, 78-495 Calle Tampb Q Owner's Name d �� rim Address: -1-7-b+5) 0.1 le- City, ST, Zip: lA Q,,.l A Z- Z GJ 3 Tel hone: 1 Project Descriptions 1c%VL�IGZ� Gtr -1 d L,, City Lia #; I61CALA qmw I " 4.1, d Out Total Permit Fees 3IWlion • sem- at Sjoaj%q - 5&w� �� t Construction Type: Occupancy: � I . Project type (circle one): New Add'a Alter Repair Demo Sq. Pt.: ## Stories: t! Units: Estimated Value of Project APPLICANT: DO NOT WRITE BELOW THIS UNE Rev'd TRACKING PERMIT PEES Plan Cheek submitted 3 5 Item Amount Reviewed, ready for corrections Plan Cheek Deposit Called Contact Person Plan Check Balance .Plane picked up f'� Construction S.W 7,Z.5-6- Plans resubmitted ' Mechanical 2' Revlew, ready for eormctiElectrical Called Contact Person Plumbing Plans picked tip S.M.L Plans. resubmitted Grading Rcgicw, ready for correctioas/issuc Developer impact Fee Call.0contact Person I.P.P. Date of permit issue Total Permit Fees 3IWlion • sem- at Sjoaj%q - 5&w� �� t MAY 10 2012 To: AJ Ortega' City'of La'Quinta B&S The following required changes have been provided for: Address: 77849 Calle Arroba, La Quinta CA 92253 Project: Hartman Residence 10.81 kW roof mounted PV system. Per plan check comments, changes have been made as follows: 1. Designers name, phone number, and wet signature have been added to every page of the planset. 2. The note for installers has been changed to "Use Individual MPPT's" to properly reflect electrical calculations. Please see PV9. 3. Connections have been clarified to be irreversibly crimped on the line diagram. Please see PV9 4. The tie-in method has been switched from a supply side connection to a standard breaker tie-in. The customer is going to upgrade his electrical panel from 200A to 225A, and maintain a 200A main breaker. In this way our system will comply with NEC 690.64(B)(2). 5. Regarding the corrections on the electrical calculators. The PVI -4.2 cutsheet has been swapped in to show our specific model. This gives a power rating for this inverter as 4200 watts. With the standard grid voltage of 240 volts, the inverter continuous output current rating will be 17.5A ( 4200 / 240 = 17.5). Please see PV13. 6. Explanation for not fusing on the DC side: Both PowerOne inverters (PVI -4.2 and PVI -6000) in this system have a maximum utility backfeed of 0 amps. The block diagram for the PVI -6000 is shown on the next page (which is also similar to the PVI 4.2). The control circuit (grey box) in the PVI -5000 senses the current and voltage from both the DC side of the inverter as well as the utility service coming from the AC side. In the unlikely event that the utility tries to backfeed our inverter through the breaker in our subpanel, the control circuit in the inverter would sense that the power coming from the DC side is not equal to the utility feed coming from the AC side. At this point, the inverter opens the grid parallel relay, and no current can flow to the DC side. Additionally, the dual MPPT'S for each inverter are kept separate right up until the AC output. Since each PV source circuit cannot be backfed from any of the other PV source circuits or from the inverter, no overcurrent protection is required on the DC side. 3055 Clearoiew Way San Mateo, CA 94402 T (650) 638-1028 (888) SOL -CITY F (650) 638-1029 SOLARCITY.COM AZ ROC 243771, CA CSL8 888104, CO EC 8041, OR CCB 180498, TX TDLR 27006 BLOCK DIAGRAM OF PVI-5000-OUTD AND PVI-6000-OUTD FOR NORTH AMERICA Cis wrr i ----------------------------------------------------- w�msx ewcuvs Nvw � ii�A ��� iea wvuuua � i 1 rum �¢ur J� NP 7 •— � �� a NA c ______________________________________________________________________________ If you have any questions about how the PowerOne inverters cannot backfeed to the DC source circuits, feel free to contact PowerOne directly. I had a lengthy conversation with Roy Allen at PowerOne about this topic. His contact information is: Roy All Field Application Engineer 760-801-5344 Please do not hesitate to get in touch with me if you have any other questions or concerns. Thank you for your time and consideration. Mike Fitch PV Designer SolarCity Inc. (650) 963-5610mfitch .solarcity.com 3055 Clearview Way San Mateo, CA 94402 T (650) 638-1028 (888) SOL -CITY F (650) 638-1029 SOLARCITY.COM AZ ROC 243771, CA CSL8 888104, 00 EC 8041, OR CCB 1.80498, TX TDLR 27006 -5 VERSION i = Cis wrr i ----------------------------------------------------- w�msx ewcuvs Nvw � ii�A ��� iea wvuuua � i 1 rum �¢ur J� NP 7 •— � �� a NA c ______________________________________________________________________________ If you have any questions about how the PowerOne inverters cannot backfeed to the DC source circuits, feel free to contact PowerOne directly. I had a lengthy conversation with Roy Allen at PowerOne about this topic. His contact information is: Roy All Field Application Engineer 760-801-5344 Please do not hesitate to get in touch with me if you have any other questions or concerns. Thank you for your time and consideration. Mike Fitch PV Designer SolarCity Inc. (650) 963-5610mfitch .solarcity.com 3055 Clearview Way San Mateo, CA 94402 T (650) 638-1028 (888) SOL -CITY F (650) 638-1029 SOLARCITY.COM AZ ROC 243771, CA CSL8 888104, 00 EC 8041, OR CCB 1.80498, TX TDLR 27006 m ABBREVIATIONS ELECTRICAL NOTES INDEX LEGEND LICENSE A AMPERE 1. WHERE ALL TERMINALS OF THE DISCONNECTING PV1 PV2 COVER SHEET SITE PLAN () E UTILITY METER & WARNING LABEL (6)* CA # 888104 ALTERNATING CURRENT MEANS MAY BE ENERGIZED IN THE OPEN C-46, C-10 BLDG BL BUILDING POSITION A SIGN WILL BE PROVIDED WARNING PV3 STRUCTURAL VIEWS INVERTER W/ INTEGRATED DC DISCO AN CONC CONCRETE OF THE HAZARDS PER ART. 690.17. PV4 STRUCTURAL VIEWS Inv & WARNING LABELS (3),(4),(5),(6) tv C COMBINER BOX 2. EACH UNGROUNDED CONDUCTOR OF THE PV5 STRUCTURAL VIEWS D DISTRIBUTION PANEL MULTIWIRE BRANCH CIRCUIT WILL BE IDENTIFIED BY PHASE AND SYSTEM PER ART. 210.5. PV6 PV7 STRUCTURAL VIEWS STRUCTURAL VIEWS , g DC DISCONNECT & WARNING LABELS (4),(5) DC EGC DIRECT CURRENT EQUIPMENT GROUNDING CONDUCTOR 3. A NATIONALLY -RECOGNIZED TESTING LABORATORY SHALL LIST ALL EQUIPMENT IN PV8 PV9 UPLIFT CALCULATIONS SINGLE LINE pc AC DISCONNECT &WARNING LABELS JURISDICTION NOTES (E) EMT EXISTING ELECTRICAL METALLIC TUBING COMPLIANCE WITH ART. 110.3. PV10 ELECTRICAL CALCULATIONS (2),(4),(6) - "ALL CONSTRUCTION G SOLAR GUARD METER 4. CIRCUITS OVER 250V TO GROUND SHALL PV11 ELECTRICAL CALCULATIONS PV12 LABELS & AHJ NOTES Q JUNCTION BOX GALV GALVANIZED COMPLY WITH ART. 250.97, 250.92(6) 5. DC CONDUCTORS EITHER DO NOT ENTER pV13 CUTSHEETS SHALL COMPLY WITH 2 010 GEC GND GROUNDING ELECTRODE CONDUCTOR GROUND BUILDING OR ARE RUN IN METALLIC RACEWAYS PV14 CUTSHEETS c � DC COMBINER BOX &WARNING LABELS (7),(9) CALIFORNIA RESIDENTIAL, HOG HOT DIPPED GALVANIZED OR ENCLOSURES TO THE FIRST ACCESSIBLE DC PV15 PV1 CUTSHEETS CUTSHEETS MECHANICAL, ELECTRICAL, I CURRENT DISCONNECTING MEANS PER ART. 690.31(E). DISTRIBUTION PANEL & WARNING 0 PLUMBING, ENERGY, A N D Imp CURRENT AT MAX POWER 6. ALL WIRES SHALL BE PROVIDED WITH STRAIN LABELS (1),(2) GENERAL NOTES INVS INVERTERS RELIEF AT ALL ENTRY INTO BOXES AS LOAD CENTER &WARNING LABELS GREEN BUILDING CODES AND. Isc SHORT CIRCUIT CURRENT REQUIRED BY UL LISTING. Lc (2),(4),(6) THE L A QUINTA MUNICIPAL kVA KILOVOLT AMPERE 7. MODULE FRAMES SHALL BE GROUNDED AT THE CODE." kW LBW KILOWATT LOAD BEARING WALL UL -LISTED LOCATION PROVIDED BY THE MANUFACTURER USING UL LISTED GROUNDING 1. THIS SYSTEM IS GRID-INTERTIED VIA A O DEDICATED PV SYSTEM METER MIN MINIMUM HARDWARE. UL -LISTED POWER -CONDITIONING INVERTER. � CONDUIT RUN ON EXTERIOR • 11.Oiq (N) NEW 8. ALL EXPOSED METAL PARTS (MODULE FRAMES, 2. THIS SYSTEM HAS NO BATTERIES, NO UPS. SOURCE INPUT CIRCUITS __- CONDUIT RUN ON INTERIOR CIT' OrIA QUINTA NEC NATIONAL ELECTRIC CODE RAIL, BOXES, ETC.) SHALL BE GROUNDED USING 3. PHOTOVOLTAIC AND AND INVERTS AND INVERTER INPUT CIRCUIT ARE — GATE - - INTERIOR EQUIPMENT BUILDING & SAFETY DEPT. NIC NOT IN CONTRACT UL LISTED LAY -IN LUGS LISTED FOR THE TO SHALL BE MADE 4. SOLAR MOUNTING FRAMES ARE TO BE APPROVED OC ONTCENTERALE ELECTRICALOYSTS CONTINUOUS WITH ATTACHED GROUNDED. -- --_ s NUMBERS REFER TO LABELS ( ) P PANEL BOARD RAIL. 5. _ ALL WORK TO BE DONE TO• THE CURRENT IB_ C.-� „ON-TSPAGE FOR CONSTRUCTION PL PROPERTY LINES 9. MODULE FRAMES, RAIL, AND POSTS SHALL BE 6. ALL ELECTRICAL WORK SHALL COMPLY -WITH PV PHOTOVOLTAIC BONDED WITH EQUIPMENT GROUND CONDUCTORS THE 2011 NATIONAL ELECTRIC CODE. Iti frt n PVC POLYVINYL CHLORIDE AND GROUNDED AT THE MAIN ELECTRIC PANEL. nATC VICINITY MAS �o■a * S SUBPANEL SCH SCHEDULE 10. THE DC GROUNDING ELECTRODE CONDUCTOR SHALL BE SIZED ACCORDING TO ART. SS SSD STAINLESS STEEL SEE STRUCTURAL DRAWINGS 250.166(6) & 690.47. PARCEL NUMBER: „ ,_�atcwn�, ,,, - - +, --� --i �'f r ��-; ail �' '� r;� •�� j ' �' � � �'1'y � -,�� ' 1 *► a STC SWH STANDARD TESTING CONDITIONS SOLAR WATER HEATER _ t, ��ua tia.,sanu•r - '- �••• A--+ ++ ,?�.• - ,r -� r 1.4 55 oa�ticwy t . �s .r _ ,,� _. ,,, 774172013-0 TYP 7; \� UON UNLESS OTHERWISE NOTED`' ��1i`-� rri , ^ �� � n�il�•u , � ; _'. ; � t� :`- ,r, ��,� pa•. IL' UPS VVOLTAGE Vm p UNINTERRUPTIBLE POWER SUPPLY VOLT AT MAX POWER '' ''sem ,g r L "' �' N:.e ° ��' _a' r — — , ' X' moi' w °' t ''; : _." LEGAL DESCRIPTION: Voc VOLTAGE AT OPEN CIRCUIT ":: M.�, r= '= '� •, r.. t ` ' ' - - 1`r% r �r i `r , a .. \ Lot 1 MB 020/025 SANTA CARMELITA / W WATT T,Q . ., a ,.! -1, I: 1 ' ■ �: I ' m _ �- -.s '"Aw1 60,6Aw lw'S0 30M Aw A. Aw 50' 1.. %I.- r VALE LA QUINTA UNIT 23 3R NEMA 3R, RAINTIGHT �1�F'"�f� t� i x A" Park ear A. it _ 9��,: ' 'F, i,"u_.1- REV BY DATE COMMENTS ,. �Ir f ��.� ` L '� e ~ e •li� r',. T•. w f` ` ,� J .S • M 67 Oi I r c La wW REV A MFlTC 4/16/2012 Plancheck Corrections +1, V4,f• p b dh CONFIDENTIAL —THE INFORMATION HEREIN CONTAINED SHALL NOT BEE USED FOR THE JOB NUMBER JB -922218 0 0 PREMISE OWNER HARTMAN, AHt La Quints DESCRIPTION: SANDY HARTMAN RESIDENCE DESGN: Mike Fitch (650-963-5610) ��'� MARKET: - REST MODULES,� 46 YINGLI YL235P-29b BENEFIT OF ANYONE EXCEPT SOLARgTY INC., NOR SHALL IT BE DISCLOSED IN WHOLE OR IN 77849 CALLE ARROBA 10.81 kW ROOF MOUNT PV SYSTEM solalcity. PART TO OTHERS OUTSIDE THE RECIPIENTS ORGANIZATION, EXCEPT IN CONNECTION WITH LA QUINTA, CA 92253 PROECT MANAGER: MDUNTNG SYSTEM: 3055 Clearview Way T:(650)638- 028 I San Mateo, CA W0638-1029 (888)-SOL-CITY(765-2489) I www.solarcity.com THE SALE AND USE OF THE RESPECTIVE SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF SOLARCITY INC. * HOLLAENDER PAGE NAME 7607774017 COVER SHEET SHEET: PV 1 REV: DATE: A 2/22/2012 PAYMENT TYPE LEASE INVERTER Multiple Inverters r t.' 'I- ROOF MOUNT TCH: 0 1 ARRAY PITCH: 10 !IkUTH: 180 ARRAY AZIMUTH: 180 4TERIAL: Rolled Roofino Torchdown / Bitumen I.yi113j RAFTERS SIZE: 2x4 . SPACING: 24" O.0 SUPPORT: 2x4 WEB MAX. SPAN: 6'-3" NOTES A CALLE ARROBA ; TRANSFORMER INFORMATION: l 906842 25' 75 KVA B PHASE TO R HIGH 7.2KV p ; LOW 120/240V INVERTER: POWERONE AURORA PVI-4.2-OUTD-S-US; ROOF MOUNT - . SPACING. SUPPORT: 2x4 WEB 1 ARRAY PITCH: 5 AZIMUTH: 225 nv,' I MATERIAL: Rolled Roofing Torchdown METER #: 16 O4SR-116412 M c1 Cb SIZE: Proposed Bi-directional meter# s Ac SUPPORT: 2x4 WEB CONFIDENTIAL — THE INFORMA71ON HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT SOLARCITY ULC.. NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE THE RECIPIENT'S ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF SOLARarr INC. 60A CUTLER -HAMMER AC�� �__ — K rte..; 0 0 - RV -1 MARKET: REST Q DISCONNECT: DG222NRB-f . I N r! I PROSECT iw,NACER * f WITHIN 5' OF MAIN PANELMP4 1-tNVERTM ROOF MOUNT - - TOR PVPITCH: 0 ARRAY PITCH: ' 5 ' POWERONE AURORA AZIMUTH: 225 ARRWA-ZIMUTH:,225:- ^ ,•_, PVI-600.0-OUTD-US MATERIAL: Rolled Roofing Torchdown Bitumen f STORY: i t Lc RAFTERS SIZE: 2x4','' - <- _ �. : .•�t�, ' . ;'; SPACING: 24"-.O.C. Bi UPPORT 2x4 WEB MP5 ROOF MOUNT AX. SPAN: 6'-8" PITCH: 0 1 ARRAY PITCH: 5 NOTES AZIMUTH: 225 ARRAY AZIMUTH: 2 MATERIAL: Rolled Roofino Torchd STORY: 1 RAFTERS SIZE: 2x4 24" 0 C M H DOSE OWER: AHd La Quinta HARTMAN, SANDY 77849 CALLE ARROBA LA QUINTA, CA 92253 7607774017 C 20' TO R J MP2 ROOF MOUNT PITCH: SPACING. SUPPORT: 2x4 WEB 1 ARRAY PITCH: 5 AZIMUTH: 225 MAX. SPAN: 4'-5" MATERIAL: Rolled Roofing Torchdown STORY: NOTES I� Cb SIZE: 2x4 s Ac SUPPORT: 2x4 WEB CONFIDENTIAL — THE INFORMA71ON HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT SOLARCITY ULC.. NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE THE RECIPIENT'S ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF SOLARarr INC. ,IDB NUMBER JB -922218 0 0 (2),(4),(6) MARKET: REST Q MODULES: 46 YINGLI # YL235P-, PROSECT iw,NACER * 0 MOUNTING SYSTEM: HOLLAENDER PAYMENT TYPE LEASE INVERTER I Multiple Inverters M H DOSE OWER: AHd La Quinta HARTMAN, SANDY 77849 CALLE ARROBA LA QUINTA, CA 92253 7607774017 C 20' TO R J MP2 ROOF MOUNT PITCH: 0 1 ARRAY PITCH: 5 AZIMUTH: 225 ARRAY AZIMUTH: 225 MATERIAL: Rolled Roofing Torchdown STORY: 1 RAFTERS RAFTERS SIZE: 2x4 SPACING: 24" O.C. SUPPORT: 2x4 WEB MAX. SPAN: 5'-4" NOTES MODULES: Yingli # YL235-29b DC Rating of array. 10.810kW PV5 0 35 TO R FRONT OF HOUSE NOTES DESCRIPTION: HARTMAN RESIDENCE 10.81 kW ROOF MOUNT PV SYSTEM PAGE NAME- SITE AMESITE P Bitumen LEGEND MP3 ROOF MOUNT F PITCH: 0 ARRAY PITCH: 5 AZIMUTH: 225 ARRAY AZIMUTH: 2 V5 MATERIAL: Rolled Roofing Torchd, STORY: 1 RAFTERS © SIZE: 2x4 SPACING: 24" O.C. Ac SUPPORT: 2x4 WEB MAX. SPAN: 5-10" NOTES DESCRIPTION: HARTMAN RESIDENCE 10.81 kW ROOF MOUNT PV SYSTEM PAGE NAME- SITE AMESITE P Bitumen LEGEND SITE PLAN Scale: 3/32" = 1' N W E S DESIGN: Mike Fitch (650-963-5610) �'- 0- O— 1 3055 Clearview Way LLT• Rfl DATE SanMateo, CA 94402 2/22/20112 T:(650) 638-1028 1 F:(650) 638-1029 PV 2 A (888) -QTY (765-2489) 1 www.solarcity.com 0 (E) UTILITY METER & WARNING LABEL (6)* INVERTER W/ INTEGRATED DC DISCO & WARNING LABELS (3),(4),(5),(6) © DC DISCONNECT & WARNING LABELS (4),(5) Ac AC DISCONNECT & WARNING LABELS (2),(4),(6) o Q JUNCTION BOX 0 Z 0 DC COMBINER BOX & WARNING LABELS (7),(9) a DISTRIBUTION PANEL & WARNING 'a ❑O LABELS (1),(2) LOAD CENTER & WARNING LABELS Lc (2),(4),(6) O DEDICATED PV SYSTEM METER Bi men CONDUIT RUN ON EXTERIOR --- CONDUIT RUN ON INTERIOR — GATE - - - INTERIOR EQUIPMENT *( ) NUMBERS REFER TO LABELS ON CUTSHEET PAGE SITE PLAN Scale: 3/32" = 1' N W E S DESIGN: Mike Fitch (650-963-5610) �'- 0- O— 1 3055 Clearview Way LLT• Rfl DATE SanMateo, CA 94402 2/22/20112 T:(650) 638-1028 1 F:(650) 638-1029 PV 2 A (888) -QTY (765-2489) 1 www.solarcity.com .�-2' TYPE' :) LBW (E) 2x4 BOX TRUSSES 24 SPACING (E) LBW PREMISE OWNER: AHd La Quinta DESCRIPTION: HARTMAN, SANDY HARTMAN RESIDENCE 77849 CALLE ARROBA 10.81 kW ROOF MOUNT PV SYSTEM LA QUINTA, CA 92253 PAGE NAME: 7607774017 ._ STRUCTURAL VIEWS DESIGN: Mike Fitch (650-963-5610) REAR VIEW OF ROOF PLANE 5 ^. SOLAR PANEL ATTACHED WITH MODULE Scale: 1/4"=1'-0" ij CLAMPS, J"-16 BOLTS, BASE WITH LAGS, AND TIGHTEN SH REV DATE PV 3 A 2/22/2012 AND NUTS (4) SOLARCITY SOLAR RAIL { U—BOLT ASSEMBLY & FIXED (2) (3) PIPE TEE W/SET SCREWS 1-1/4" (SCH. 40 PIPE) STEEL (4) PIPE ASTM A53 GR. B 5. 4' j! r (E)- MOD. BITUMEN C 2'-6" Pv3 2'-8" 3'— 3 (E) ROOF DECKING 17'-3" (2) A" DIA LAG BOLT — (2—j" EMBED, MIN) (E) RAFTER (E) LBW SIDE VIEW OF ROOF PLANE 5 RAFTERS: 2x4 @ 24" O.C. SUPPORT: 2x4 WEB Scale: 1/4"=1'-0" MAX SPAN: 4'-5" � STANDOFF 1 CONFIDENTIAL — THE INFORMATION HERON CONTAINED SHALL NOT BE USED FOR THE NORBENEFITSH OF ANYONE EXCEPT IN WHOLE INC., NOR SHALL IT BE DISCLOSED IN WHOLE OR IN NOR PART IZ OTHERS OUTSIDE THE RECIPIENTS ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF SOLARCITY INC. INSTALLATION ORDER PREMISE OWNER: AHd La Quinta DESCRIPTION: HARTMAN, SANDY HARTMAN RESIDENCE 77849 CALLE ARROBA 10.81 kW ROOF MOUNT PV SYSTEM LA QUINTA, CA 92253 PAGE NAME: 7607774017 ._ STRUCTURAL VIEWS DESIGN: Mike Fitch (650-963-5610) (1) CLEAN ROOF DECK APPLY M1 SEALANT BENEATH (2) FLANGE BASE AND ON PENETRATION POST. MOUNT MOUNTING SYSTEM: HOLLAENDER BASE WITH LAGS, AND TIGHTEN SH REV DATE PV 3 A 2/22/2012 POST W/ CHANNEL LOCKS. (4) M-1 STRUCTURAL SEALANT (2) (3) AT BASE OF CHEMCURB AND AROUND PENETRATION. (4) 1 PART POURABLE SEALANT. ` CONFIDENTIAL — THE INFORMATION HERON CONTAINED SHALL NOT BE USED FOR THE NORBENEFITSH OF ANYONE EXCEPT IN WHOLE INC., NOR SHALL IT BE DISCLOSED IN WHOLE OR IN NOR PART IZ OTHERS OUTSIDE THE RECIPIENTS ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF SOLARCITY INC. JOB NUMBER JB -922218 O O PREMISE OWNER: AHd La Quinta DESCRIPTION: HARTMAN, SANDY HARTMAN RESIDENCE 77849 CALLE ARROBA 10.81 kW ROOF MOUNT PV SYSTEM LA QUINTA, CA 92253 PAGE NAME: 7607774017 ._ STRUCTURAL VIEWS DESIGN: Mike Fitch (650-963-5610) �:, ; • �Of � ' � MARKET; .REST MODULES:- ODULES 46 YINGLI YL235P-29b PROECT MANAGER: * MOUNTING SYSTEM: HOLLAENDER 3055 Clearview way A 94402 San Mateo, T:(650) 638-1028 1 F:( 650) 638-1029 (888)SOL-CIT`((765-2489) I www.solarcty.com SH REV DATE PV 3 A 2/22/2012 PAYMENT TYPE: LEASE INVERTER Multiple Inverters i r' r REAR VIEW OEROOF PLANE 4 Scale: 1/4"=1'-0" (E) LBW PV3 5' 1 2'-6'> — 2'-11 rr 3'-6'r 13'": F—8" —^rr (E)BW (E) LBW G SIDE VIEW OF ROOF PLANE 4 RAFTERS: 2x4 @ 24" O.C. SUPPORT: 2x4 WEB Scale: 1/4"=1'-0" MAX SPAN: 6'-8" CONFIDENTIAL – THE INFORMATION HEREINIOII NUMBER JB -922218 O O PREMISE OHNE: W La Quinta DESCRIPTION: DESIGN: SH CONTAINED ALL NOT BE USED FOR THE HARTMAN, SANDY HARTMAN RESIDENCE Mike Fitch (650-963-5610)BEN M"`` RESI Y0D11 46 YINGLI YL235P-29b NOREFIT OF SHALL ITNYONE EXCEPT BE DISCLOSED SN OLE OR IN OLARCITY INC.. 77849 CALLE ARROBA 10.81 kW ROOF MOUNT PV SYSTEM ��fa�jPART iV. TO OTHERS OUTSIDE THE RECIPIENTS ORGANIZATION, EXCEPT IN CONNECTION WITH LA QUINTA, CA 92253 PROJECT MANAGER: MOUNTING SYSTEM: THE SALE AND USE OF THE RESPECTIVE SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN ; HOLLAENDER PAGE NAME 3055 Clearview Way San Mateo, CF 94402 SHEET' EW DATE PAYMENT TYPE: LEASE INVERTER, Multiple Inverters PERMISSION OF SOLARCITY INC. 7607774017 STRUCTURAL VIEWS PV 4 A 2/22/20121 / T:(650) 638- 028 1 (650) 638-1029 (888)-SOL{TTY (765-2489) 1 www.solardty.can t 5' (E) LBW REAR VIEW OF ROOF PLANE 3 {� Scale: 1/4"=1'-0" SIDE VIEW OF ROOF'PLANE 3 RAFTERS: 2x4 W 24" O.C. SUPPORT: 2x4 WEB Scale: 1/4"=1'-0" MAX SPAN: 5-10" CONFIDENTIAL –THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT SOLARCITY INC_ NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE THE RECIPIENTS ORGANIZATION, EXCEPT IN CONNECTION WITH THE SAIF AND USE OF THE RESPECTIVE SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF SOLARCITY INC. JOB NUMBER J B-922218 0 0 PREMISE OWNER: AHd La Quinta DESCRIPTION: HARTMAN, SANDY HARTMAN RESIDENCE 77849 CALLE ARROBA 10.81 kW ROOF MOUNT PV SYSTEM LA QUINTA, CA 92253 PAGE NAME 760777401 7 STRUCTURAL VIEWS DESIGN: Mike Fitch (650-963-5610) _ • Solaltity. MARKET: RESI. ` , MODULES: 4s YINGLI YL235P-29b PROJECT MANAGER. # MOUNTING SYSTEM: HOLLAENDER 3055 GearvieW Way San Ma8I CA 94402 7:(650)638-1028 I F:(650)638 -1-I I WW'�'.�arcity.can $HEFT: REV DAIS 2/22/2012 PV 5 A(888}SOL�TY(765-2489) PAYMENT TYPE: LEASE INVERTER: Multiple Inverters REAR VIEW OF ROOF PLANE 2 ' Scale: 1/4"=1'-0" 5' � :=� I 3'-9" r2'-10" 53— 15'-8" f5'-4" —3" 5'-4" (E):::LBW (E) LBW SIDE VIEW OF ROOF PLANE'2 RAFTERS: 20 @ 24" O.C. SUPPORT: 2x4 WEB Scale: 1/4"=1'-0" MAX SPAN: 5'-4" (E) LBW CONFIDENTIAL - THE INFORMATION HEREIN CONTAINED MALL NOT BE USED FOR THE JOB NUMBER JB -922218 O O PREMISE OWNER: AM La Quanta "° DESCRIPTION: HARTMAN, SANDY HARTMAN RESIDENCE UL51GN: Mike Fitch (650-963-5610) MARKET: RESI � MODULES 46 YINGLI YL235P-29b BENEFIT OF ANYONE EXCEPT IN VMOTY MC., NOR SHALL IT BE DISCLOSED IN WHOLE OR IN 77849 CALLE ARROBA 10.81 kW ROOF MOUNT PV SYSTEM 'Sol m Sol�rc'� PART TO OTIM OUTSIDE THE RECIPIENTS ORGANIZATION, EXCEPT IN CONNECTION WITH LA QUINTA, CA 92253 PROJECT NANAf R: MOUNTING'SYSTEM: THE SALE AND USE OF THE RESPECTIVE SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN * HOLLAENDER PAGE NAME 3055 ateo, CA Way San Mateo, CA 94402 REV: DAA; PAYMENT TYPE: LEASE 1N1Qt7Q� Multiple Inverters PERMISSION OF SOLARCITY INc. 7607774017 STRUCTURAL VIEWS 2/22/2012 PV 6 A(888)-SOL-CITY(765-2489) T:(650)638-1028 1 R(650)638-1029 1 www.solarcity.com REAR VIEW~OF ROOF PLANE 1 Scale: 1/4"=l' -O" (E) LBW (E) LBW _lk (E) LBW SIDE VIEW OF ROOF PLANE 1 RAFTERS: 2x4 @ 24" O.C. A SUPPORT: 2x4 WEB Scale: 1/4"=1'-0" MAX SPAN: 6'-3" CONFIDENTIAL –THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE ,q8 NUMBER JB -92221 8 0 0 PREMISE ONNER MU La QuInta HARTMAN, SANDY DESCRIPTION: HARTMAN RESIDENCE DESIGN: Mike Fitch (650-963-5610) • NOR SH OF ANYONE EXCEPT IN WHOLE INC., NOR SHALL IT BE DISCLOSED IN WHOLE OR IN MARKET: RESI MODULES 46 YL235P-29b 77849 CALLE ARROBA 10.81 kW ROOF MOUNT PV SYSTEM " O'� '�yo PART TO OTHERS OUTSIDE THE RECIPIENTS ORGANIZATION, EXCEPT IN CONNECTION WITH PROJECT MANAGER: ..YINGLI MOUNTING SYSTEM: LA QUINTA, CA 92253 THE SALE AND USE OF THE RESPECTIVE SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN * HOLLAENDER PAGE NAME 3055 Clearview way San Mateo, CA 94402 SHS: REV: DATE PERMISSION OF sOLARCITY INC. PAYMENT TYPE LEASE INVERTER Multiple Inverters 7607774017 .,, STRUCTURAL VIEWS PV 7 A 2/22/2012 T:(650) 638-1Oz8 I F:(650) 638-1Oz9 (888) -SOL -CITY (765-2489) 1 www.solaraty.com :t UPLIFT CALCULATIONS INPUT VARIABLES_; CONFIDENTIAL — THE INFORMATION HEREIN NUMeETs O O JB -922218 CALCULATIONSAND VALUES NOISE OWNER: aHa La Quints rr e• DESCPoP110N: HARTMAN, SANDY HARTMAN RESIDENCE DESIGN* Mike Fitch (650-963-5610) Required Variables Design wind pressures based upon: Mean Roof Height: 18 ASCE 7-05 Chapter 6 Wind Loading Exposure Category: C Equation 6.5.13.3: Component and Cladding Elements Basic wind speed (or city in the future): 85 Wind pressure P = qh*Cn*G Importance factor (1 for residential): 16.5.10: Velocity pressure EPT IN ORGANIZATION, IXCEPT IN CONNECTION WI1H qh =0.00256*Kz*Kzt*Kd*V^2*1 Roof shape: pitched ! From Table 6-3: Roof Angle (degrees): 2 Kz = 0.88 Roof zone: 3 * Contiguous sq. feet of array: 211 From Figure 6-4: Kzt = 1.00 Least width of the building: 50 C' Obstructed wind flow? TRUE From Table 6-4: PERMISSION OF SOLARCITY INC. Kd = 0.85 Local Topographical Features T:(650)638-1028 I F:(650)638-1029 (888)-SOL{SrY(765-2489) I wwwsolarcity.can (choose "standard " or refer to pictures right, and below) From figure 6-1: j� V=85 Type of hill: none Hill height (h) (ft): From table 6-1: Slope of hill (degrees): I = 1 Horizontal distance from hilltop to house (x): _ # From Velocity Pressure Equation Height from bottom of hill to mean roof height (z): qh = 13.84 h y From Figure 6-198 Design Wind Pressure P (lbs. per sq. ft.) = qh*Cn*G Cn (uplift) _ -1.33 Pd (downforce pressure) = Cn (down) = 0.50 Pu (uplift pressure) = FEW From 6.5.8.1 G = 0.85 Max Tributary Area Feet Inches Pipe Rack or X -Y X (E -W distance between standoffs) = 4 0 Yingli YL235 P -29b Y (N -S distance between standoffs) = 6 0 Amax (sq. ft.) = 0.5*L*X _ Staggered Penetrations = Yes L (length of panel in ft. perpendicular to rail) N/A Module Rail Max. Span/Cantilever (in) = 72 36 X = 4.00 Y = 6.00 Max Uplift Force on a Single Standoff L= 9.85 Pmax (lbs.) = Amax*Pu Amax = 19.70 309 Dead Load Calculations Factor of safety = FI*D*NI/Pmax DL (lbs/sq. ft.) = (Mm+Mh)/(L*W) 5/16 x 4 in. = Lag size and length 984 = Capacity (Ibs) of 1 lag (NDS) L (length of modules) 5.41 2 = NI (number of lags per standoff) W (width of modules) 3.25 6.37 = Factor of safety Mm (weight of modules) 43.65 Point Load Calculations Mh (weight of hardware per module) = 6.59 PL (Ibs) = Amax*DL DL = 2.86 56 CONTAINED MALL NOT BE USED FOR THE NOISE OWNER: aHa La Quints rr e• DESCPoP110N: HARTMAN, SANDY HARTMAN RESIDENCE DESIGN* Mike Fitch (650-963-5610) `����' �: NARKEL RESI - YOOULES 46 YINGLI YL235P-29b BENEFIT OF ANYONE EXCEPT SOLARCIIY INC, NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS THE RECIPIENTS 77849 CALLE ARROBA 10.81 kW ROOF MOUNT PV SYSTEM LA QUINTA, CA 92253 �? SO���I o PRQJEer MANAGER EPT IN ORGANIZATION, IXCEPT IN CONNECTION WI1H ti �` MOUNTING SYSTEM: 3055 Clearview way THE SALE AND USE OF THE RESPECTIVE SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN * HOLLANDER PAGE NAME San Mateo, CA 94402 SHEET- REV: DATE: PAYMENT TYPE LEASE INVERTER Multiple Inverters PERMISSION OF SOLARCITY INC. 7607774017 UPLIFT CALCULATIONS PV 8 A 2/22/2012 T:(650)638-1028 I F:(650)638-1029 (888)-SOL{SrY(765-2489) I wwwsolarcity.can GROUND SPECS GENERAL NOTES ;) INVERTER SPECS MODULE SPECS LICENSE OND (N) #6 GEC TO (E) LIFER AT PANE N 225A MAIN SERVICE PANEL Inv 1: DC Ungrounded INV 1 —(1)POWER-ONE Inverter ((!AIL; �@ URORA PVI-4.2-OUTD-S-US 420OW, 277v/24OV/208V, 9 9969E — 46 Y1NGU YL2 SP -29b Pv Module P 2011); 235W, 211.2W PTC, H4, 50MM, Silver Frame CA # 888104 WITH IRREVERSIBLE CRIMP N; 200 2P MAIN CIRCUIT BREAKER Inv 2: DC Ungrounded Voc: 37 C-46, C-10 INV 2 on Tie -In: Supply Side Connection —(1)POWER-ONE Inverter (-2 q URORA PVI -600 —OU —US �pB` gg G111 60DOW, 277V24OV208V, 96.5%796.59:/969: VpmoX: ; 29.5 Meter Number:lB4SR-116412 *MODULE CURRENT RATINGS ARE SHOWN AS Isc AND Imp IN INV 3 THE DC STRINGS IDENTIFIER OF THE SINGLE LINE DIAGRAM. MAIN SERVICE PANELInverter 1 CUTLER -HAMMER BRYANT 13 9 8 Disconnect 7 Load Center 5 POWER -ONE C 1 Dc+ 200A 2P A 60A AURORA PVI-4.2-OUTD-S-US Dc- I String(s) Of 11 On MP 1. (E) LOADS B 25A/2P zaavr------ _ ---------------- - - - - -J EGCIGEC • n 1 GFP/GFCI DC+ - I 10 1 r-- -- N _ _ ------------- —— ——— — — — — —— — GND —� r — N DC- EGC DC+ --- — ; O DC I 2 DC+ DC I String(s) Or 9 On MP I ��__— B I I I`� L_ GND EGCIGEC ---------- - - - j ------ I _____� ,,, __________ Z ------------- I I _GEC _ -p------------ _ - - - --- - - - - - - - - - -— - - - - -- ------- EGC/GEC I 1 1 I 1 1 # 10 Jumper WOAO/2P :; 9 _ � J ; Inverter 2 N 1 BONDED WITH EGCU 1 6 POWER -ONE 14 li C 3 Dc+ IRREVERSIBLE 1 String(s)Of 13 1 CRIMP I AURORA PVI-6000-OUTD-US DC- Split over MP2-MP5 1 1 35A/2P I •• ----- - --------___- GEC 1 1 I % L1 zwv - ---� --------------- - r EGC/GEC _ I GFPIGFCI DC+ I 12 " ( I TO 120/240V 1 N DC- i .r, r^t 1 4 1 SINGLE PHASE UTILITY 1 t �—--------————— ——————— —— — — —— —— l EGC DC+ --- -- DC+ ltoverMP2-M3 1 �N DC- Split over MP2-MP5 1 1 � GND EGC/GEC _ — _ _ _ _ _ _ ------' — — DC------------------� I —--———————————————————— _GEC _ — ------------ _ ------- EGC/GEC I #10 Jumper 1 TRANSFORMER INFORMATION: —1— METER NUMBER: 1B4SR-116412 CITY OF LA QUINTA 906842 Proposed By -Directional meter#-_ :• ^. 75KVA B Phase' BUILDING & SAFETY DEPT. INVERTER'S MAXIMUM UTILITY BACKFEED CURRENT IS 0 AMPS High 7.2KV Low 120/240V p p� A P R OVE Li p" {" __ NOTE FOR INSTALLERS: QA TTF FOR CONSTRUCTION USE INDIVIDUAL MPPT'S SOURCE CIRCUITS & OUTPUT CIRCUITS HAVE BEEN SIZED IN , DANCE WITH 690.8(B) AND EXCEPTION (b) OF 690.9(A) HAS TO 120/240V 1 APPLIED. PER UL1741 LISTING THE GRID—CONNECTED INVERTER SINGLE PHASE ISCONNECT BEFORE SUPPLYING DC CURRENT TO THE PV COF DATE T CIRCUIT, AND IS NOT CONSIDERED AS A POSSIBLE SUPPLY UTILITY SERVICE E OF THE CONDUCTORS. REFER TO CUTSHEET FOR VALIDATION ' ERTER UL1741 LISTING AND COMPLIANCE. POI (1)(N) 60A/2P PV BACKFEED BREAKER A (1)CUTLER—HAMMER $ DG222URB /�C Disconnect- 60A, 24OVac Non—Fusible, NEMA 3R A (1)Conduit Kit; 3/4" EMT � C (2)HOFFMAN 8 A6R64 D� Enclosure; NEMA 3R SOURCED TO MATCH (N) MAIN PANEL — (1 )CUTLER—HAMMER'# DGlOOkB (1 )AWG #6, Solid Bare Copper GEC _ 2 Port —(B)Multi—Cable B)Mul ia14bAWG�Samte Ground/Neutral it; 60-100A, General Duly (DG) ........................................................ s (1 )Conduit Kit; 3/4" EMT ® W_(1 )AWG #6, Solid Bare Copper GEC • B (1 )BRYANT �BR816L125RP -~ ................................................ Load Center; 125A, 120�24OV, NEMA 3R — (I ) CUTLER—HAMM BR215 Breaker; 25A_HAMM2P, 2 Syaces BIRpaces — (1) CBrea Breaker; 35A 2P.2 S (1)AWG 16, THWN-2, Block � Olot— (i ) AWG 16, THWN-2, Red O 1 AWG X10, THWN-2, Black — i AWG d6, Solid Bore Copper GEC (1) AWG #10, THWN-2, Red 1 AWG #8, THWN-2, Red Voc = 407 VDC O (1) AWG #8, THWN-2, Black Vmp 324.5 VDC Isc = 8.54 ADC Imp= 7.97 ADC 2 AWG 510, PV WIRE, Black Voc = 407 VDC Isc = 8.54 ADC O (1) AWG #6, Solid Bare Copper EGC/GEC Vmp = 324.5 VDC Imp= 7.97 ADC II�L (1) AWG $6, THWN-2, White NEUTRAL Vmp =240 VAC Imp = 48.0 AAC L -L ILII �===CELL (1) AWG #10. THWN-2, White NEUTRAL Vmp =240 VAC Imp = 20.0 AAC ...... - (1) AWC ¢10, THWN-2, Green . EGC .... - (1) Conduit. Kit; .3/4' (1)AWG j6, THWN-2, Black EMT ......... ...... - (1) AWG. #10, THWN-2, Green . EGC .... - S 1) Canduit Kit; 3/4" EMT .. _ .. _ . _ - Q ( ) � B6 . Copper (1)AWG 8, THWN-2, Black — 1 AWG Solid Bare C er GEC (1) AWG #8, THWN-2, Red Voc ® (1)AWG #8, THWN-2, Black Vmp 333 VDC = 265.5 VDC Isc 8.54 ADC Imp= 7.97 ADC 2 AWG #10, PV WIRE, Black Voc = 333 VDC Isc = 8,54 ADC ( )6, Solid Bare Co er EGC GEC Vm = 265.5 VDC Imp= 7.97 ADC O 1 AWG Copper / P p= ®� (1 ) AWG j16, THWN-2, Red ©� (1 ) AWG #8, THWN-2, Red — (1) AWG #6, THWN-2, White NEUTRAL Vmp =240 VAC Imp = 48.0 AAC - 1 ) AWG #10, THWN-2, Green EGC — (1) Conduit Kit; 3/4' EMT "` (1) AWG J10, THWN-2, White NEUTRAL Vmp =240 VAC Imp = 28.0 AAC — (1) AWC y10, THWN-2. Green EGC - (1) Conduit. Kit; 3/4' EMT (1 ) AWG #8, THWN-2, Red Voc © (1) AWG #8, THWN-2, Black Vmp 481 VDC = 383.5 VDC Isc 8.54 ADC Imp= 7.97 ADC (2 )AWG X10, PV WIRE, Black Voc = 481 VDC Isc = 8.54 ADC O (1) AWG #6, Solid Bare Copper EGC/GEC Vmp = 383.5 VDC Imp= 7.97 ADC .................. O (i) AWG j6, Solid Bare Copper GEC . , , , , , (1 )AWG #8, THWN-2, Red Voc = 481 VDC Isc = 8.54 ADC . _ , , . , . (2')AWG #10, PV WIRE, Black Voc —_'4 VDC Isc = 8.54 ADC © (1 )AWG ®8, THWN-2, Black Vmp = 383.5 VDC Imp= 7.97 ADC ® (1 )AWG #6, Solid Bare Copper EGC/GEC Vmp = 383.5 VDC Imp= 7.97 ADC ar. CONFIDENTIAL — THE INFORMATION HEREIN JOB NUMBER: JB -922218 0 0 �1 Quin DESCRIPTION: DE9L;r1 CONTAINED SHALL NOT BE USED FOR THE HARTMAN, SANDY HARTMAN RESIDENCE Mike Fitch (650-963-5610)BEN �:, , • Ma ET: RESI "0D11� 46 YINGLI YL235P-29b NOREFIT OF SHALL IT BEN DISCLOSED IN MOLE OREXCEPT SOLARCITY CIN 77849 CALLE ARROBA 10.81 kW ROOF MOUNT PV SYSTEM wf� SolarC�ty PART TO OTHERS OUTSIDE THE RECIPIENT'S ORGANIZATION, EXCEPT IN CONNECTION WITH LA QUINTA, CA 92253 PROXCT MANAGER: MOUNTING SYSTEM: THE SALE AND USE OF THE RESPECTIVE SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN * HOLLAENDER PACE NAME 3055 Clearview Way San Mateo, CA 94402 SHEET- REV DATE PAYMENT TYPE: LEASE INVERTER: Multiple Inverters PERMISSION OF SOLARCITY INC. • 760777401 7 t� SINGLE LINE 2/22/20121 PV 9 A(888) T:(650) 638-1028 I F:(650) 638-1029 -SOL -CITY (765-2489) 1 www.solarcity.com a. Conductor must have 30 deg. C ampacity >= 125% of continuous current per Art 215.2(A)(1). b. Conductor must have (after corrections for conditions of use) >= continuous current per Table 310.16. c. Evaluate conductor temperature at terminations per 110.14(C).' Ampacity of wire derated for conditions of termination must be >= continuous current*1.25. All string terminations are rated at 90" C. ------------------------------------------ 2. OCP Sizing per Art 690.8(6)(1) a. Round up to next size per Art 240.4(B) ------------------------------------------- 3. Conductor Sizing per Art 690.8(B)(1) a. Conductor must have 30 deg. C ampacity >= 125% of continuous current per Art 215.2(A)(1). b. Conductor must have (after corrections for conditions of use) >= continuous current per Table 310.16. c. Evaluate conductor temperature at terminations per A� Ampacity of wire derated for conditions of terminatio >= continuous current*1.25. All branch terminations a 75' C min. ------------------------------------- 4. OCP Sizing a. Round up to next size per Art 240.4(B) ------------------------------------- 5. Conductor Sizing per Art 690.8(6)(1) a. Conductor must have 30 deg. C ampacity >= 125% of current per Art 215.2(A)(1). n1 OF LA C�UI�1 gWE)ING & SAFETY DI FOR CONSTRUCTIC b. Conductor must have (after corrections for conditions of use) >= continuous current per Table 310.16. c. Evaluate conductor temperature at terminations per Art 110.14(C). Ampacity of wire derated for conditions of termination must be >= continuous current*1.25. All inverter output terminations are rated at 75' C. ------------------------------------------- 6. OCP Sizing a. Round up to next size per Art 240.4(B) 7. Conductor Sizing per Art 690.8(B)(1) a. Conductor must have 30 deg. C ampacity >= 125% of continuous current per Art 215.2(A)(1). b. Conductor must have (after corrections for conditions of use) >= continuous current per Table 310.16. c. Evaluate conductor temperature at terminations per Art 110.14(C). Ampacity of wire derated for conditions of termination must be >= continuous current*1.25. All inverter output terminations are rated at 75' C min. CONFIDENTIAL - THE INFORMATION HEREIN loe NUMBE,t JB -922218 00 CONTAINED SHALL NOT BE USED FOR THE PVI -4.2S96.0% 4,200 4, 10 BENEFIT OF ANYONE EXCEPT SOLARCnY INC., MARKET: MODULES NOR MALL IT BE DISCLOSED IN WHOLE OR IN . REST 46 YINGLI #YL PART TO OTHERS OUTSIDE THE RECIPIENTS I Imp (A) Max. Length (ft) IWire ORGANIZATION, EXCEPT IN CONNECTION WITH MANAGER MOUNTING SYSTEM: THE SALE AND USE OF THE RESPECTIVE * HOLLAENDER SOLARGTY EQUIPMENT, WITHOUT THE WRITTEN PAYMENT TYPE INVERTER PERMISSION OF 50LARCITY INC. LEASE Multiple Inverters BY_ ELECTRICAL CALCULATIONS Module: 20 Yingli Y1235P-29b 211.21 Inv Pwr W PTC Strten Voltage Drop Calculations Version 5_8.18 Inverter 1:. f 1�Power-0ne PVI -4.2S96.0% 4,200 4, 10 Vdrop = Imp ' (2 ' Length)' Resistance / mp) Module: 26 Yh4i YL236P-29b 211.2 I Imp (A) Max. Length (ft) IWire Inverter 2: 1 Power -One PVWkOO-S 98.5% 6,000 571§§F -String: 1 7.97 25 1 C AWG 10 at Max Ave Hi: 107 deg F Module: Vdrop = (7.97 A " 50 ft " 0.00124 Ohms) / 271 V = 0.18% Inverter 3: _ Branch: F 7.97 30 D AWG 08 at Max Ave Hi: 107 deg F Module: r Vdrop = (7.97 A ' 60 ft *0.00078 Ohms) / 271 V = 0.14% Inverter 4: _ _ Total voltage drop in DC conductors Inverter: 1 17.50 10 1 C AWG 10 1 at 240V Total: ® modules Total Inv Pwr10, 354 PTC Vdrop = 17.50 A . 20 ft • 0.00120 Ohms) / 240 V 0.18% Photovoltaic Module Electrical Specifications: V Total STC 10,810 t deg F deg C Combined Vdrop = 42.50 5 (42.50 A ' 10 ft E AWG O6 ' 0.00049 Ohms) / at 240V 240 V 0.09% Voc= 37 Vmp= 28.5 V Record Low Temp: 13 1 Total voltage drop in AC conductors Isc= &54 A Max Average Hi Temp: 107[41.66671 Total voltage drop in AC and DC conductors = 0.58% Imp= 7.97 A Tvoc= -0.1 V/deg C Power -One Strings: iadual Tisc= 6.12 mA/deg C String Type A and 2 Combined Strings Type A Voc Correction Method: Manuf Tvoc data Branch Circuit Type A 1 -way wire length:30 ft Power -One PV14.2-S ° 1 strings per branch 1 1 strings per branch 2 11 iyingli YL235P-29b Inverter Min Vdc Input: 90 Vdc 11 modules per series string 9,modules per series string 40 V Min Vmp at Max Temp: 271 Vdc Voc= 40 V 3 324. V Max Voc at Min Temp:461 Vdc Vmp= 324.5 V 28. vnt:; A Inverter Max Vdc Input: Vdc Isc= 8.54 A 7.9 A Max String Size: 1 �25jft Imp= 7.97 A 7.9 10. A Art 690.8(AX1) 1 -way wire length: Icont= 1 10.68 A 10. A Art 690.8(A)(1) 1.a Conductor.,C AWG 10 JPV Wire :. 2.a Conductor 11D AWG 08 THWN-2 Conductor 2:1D AWG 08 THW N-2 Conductor 1: Conductor 2: N Icont ' 1.25 = (Amps) 13.34 Icont ' 1.25 = (Amps) 13. 13.3Z 30 deg C ampacity = 40 - ---- - 30 deg C ampacity = 55 1.b Icont= (Amps) 13 ' -^ r ) 2.b I Ront= (Amps) 13.13.34 Start ampacity _ ' `3 Start ampacity 55 Temperature derate (%=F) 0.41, _ Temp. derate (%=F) 0.41 0.41 1 Conduit fill derate (%=#) 1 Cndt. fill derate (%=#) 0. 0.8 - Derated ampacity I& � Derated ampacity 18. 18.04 E f Term 1 Term 2 1.c Icont'1.25= (Amps) 13. ° r J Temp tableSdeg 7 g Ampacity 2.c 1 Icont"1.25= (Amps) 13.34 13. t Ampacity50 50 1.d Icont " 1.25 = (Amps) 13.34 2.dr EGC C AWG 10 C AWG 10 Art. 250.122 OCP size = 1$r OCP size = Inverter Type A Output Combined Inverter Output Power -One PV1.4.2S 1 -way wire length: 10 ft Service Voltage= 240 Volts (cont= 17. A Art 690.8(AX1) Total Inverter Power -®1 Watts Icont = # of inverters'max inverter current 1 -way wire length: E]5ft Art 690.8(A)(1) 3.a Icont *1.25 = (Amps) 21.88 A Art 690.8(8X1) OCP size= 2 A Art. 240.6(A) Ront = (Amps) 42-34 3.b Conductor IC AWG 10 THWN-2 at.90 deg C: Table 310.15(BX16) 4.a Ront'1.25 = (Amps) 53.13 A Art 690.8(8)(1) (cont ' 1.25 = (Amps) OCP size = A Art. 240.6(A) 4.b Conductor JE AWG 06 Icont " 1.25 = (Amps) THWN-2 at 90 deg C: Table 310.15(BX16) ff, 30 deg C ampacity 44 3.c Icont= (Amps) 17.50 Start ampacity 30 deg C ampacity = 7 4.c Ront= (Amps) 42.59 Temperature derate (%=F) 0.91' Conduit fill derate (%=#) 1 Start ampacity 7 Derated ampacity 36. Temp. derate (%=F) Cndt. fill derate (%=#) 0.91 1 3.d Icont'1.25= (Amps) 21.88 Ampacity Derated ampacity N. 3.e EGC = C AWG 10. Art. 250.122 4.d Icont'1.25= (Amps) 53.13 GEC = D AWG 08 Art. 690.47, 250.166(B) Ampacity 651 PRE111SE OWNER: AW La Quina HARTMAN, SANDY 77849 CALLE ARROBA LA QUINTA, CA 92253 7607774017 2 HARTMAN RESIDENCE 10.81 kW ROOF MOUNT PV SYSTEM PAGE NAME- ELECTRICAL AMEELECTRICAL CALCULATIONS Mike Fitch (650-963-5610) • =� .olarCity 3055 aearview Way SHEET: REV: DATE San Mateo, CA 94402 2/2212012 T:(650) 638-1028 1 F:(650) 638-1029 PV 10 A (888)-SOLrrrr(765-2489) 1 www.sdarcity.con a. Conductor must have 30 deg. C ampacity >= 125% of continuous current per Art 215.2(A)(1). b. Conductor must have (after corrections for conditions of use) >= continuous current per Table 310.16. c. Evaluate conductor temperature at terminations per 110.14(C). Ampacity of wire derated for conditions of termination must be >= continuous current*1.25. All string terminations are rated at 90, C. ------------------------------------------ 2. OCP Sizing per Art 690.8(8)(1) a. Round up to next size per Art 240.4(B) ------------------------------------------- 3. Conductor Sizing _per Art 690.8(B)(1) a. Conductor must have 30 deg. C ampacity >= 125% of continuous current per Art 215.2(A)(1). b. Conductor must have (after corrections for conditions of use) >= continuous current per Table 310.16. c. Evaluate conductor temperature at terminations per Art 110.14(C). Ampacity of wire derated for conditions of termination Fill W"qq >= continuous current*1.25. All branch terminations are r lteLJTY OF LA QUID ---- C min_______________________________ BUILDING &SAFETY C 4. OCP Sizing i�r�0V1 - ---- Round up to next size per Art 2) - FOR CONSTRUCTI( 5. Conductor Sizing per Art 690.8(B)(1) a. Conductor must have 30 deg. C ampacity >= 125% of cs BY current per Art 215.2(A)(1). DATE b. Conductor must have (after corrections for conditions of use) >= continuous current per Table 310.16. c. Evaluate conductor temperature at terminations per Art 110.14(C). Ampacity of wire derated for conditions of termination must be >= continuous current*1.25. All inverter output terminations are rated at 75' C. ------------------------------------------- 6. OCP Sizing a. Round up to next size per Art 240.4(8) 7. Conductor Sizing per Art 690.8(8)(1) a. Conductor must have 30 deg. C ampacity >= 125% of continuous current per Art 215.2(A)(1). b. Conductor must have (after corrections for conditions of use) >= continuous current per Table 310.16. c. Evaluate conductor temperature at terminations per Art 110.14(C). Ampacity of wire derated for conditions of termination must be >= continuous current*1.25. All inverter output terminations are rated at 75' C min. CONFIDENTIAL - THE INFORMATION HEREIN JOB NUMBER JB -922218 00 CONTAINED SHALL NOT BE USED FOR THE Voltage Drop Calculations MARKET: MODULES:- ODULESNOR BENEFIT OF ANYONE EXCEPT SOLARCITY INC., NORSHALL IT BE DISCLOSED IN WHOLE OR IN REST 46 ' YINGLI #YL PART TO OTHERS OUTSIDE THE RECIPIENT'S PROJECT MANAGER MOUNTING SYSTEtI: ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE * HOLLAENDER SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PAYMENT TYPE INVERTER PERMISSION of SOLARCITY INC. LEASE Multiple Inverters ELECTRICAL CALCULATIONS Module: 20 Yingli YL235P-29b 211.2 Inv Pwr W PTC StrLen Voltage Drop Calculations Version 5_8.18 Inverter 1: t 1 Power -One PVI -4.2-S 96.096 4,200' 4 0 10 Vdrop = Imp) 2 ' Length 'Resistance) / Vmp Module: 26 Yingli YL235P-29b _ _ _ I Imp (A) Max. L"ength'(ft) Wire Inverter 2: 1f� 1 Power -One PVI -6000-S 96.b% 6,0001 5,299 String: 7.97 35- C AWG 10 . ' at Max Aye Hi: 107 deg F Module: L� Vdrop = (7.97 A 70 ft - 0.00124 Ohms) / 320 V = 0.22% Inverter 3: f Branch: 7.97 75 D AWG 08 at Max Ave Hi: 107 deg F Module: L.� Vdrop = (7.97 A 150 ft ' 0.00078 Ohms) / 320 V = 0.29% Inverter 4: ` � Total voltage drop in DC conductors =ILL% Inverter: 1 25.00 10 D AWG 08 at 240V Total: ®modules Total Inv Pwr 10 ,?Pp 97q PTC Vdrop = (25.00 A 20 ft --425-0 -T- ' 0.00078 Ohms) / 240 V 0.16% Photovoltaic Module Electrical Specifications: V Total STCJ 10,810 ( deg F deg C Combined Vdrop = F (42.50 A 10 ft 1 E AWG 06 ' 0.00049 Ohms) / at 240V 240 V 0.09% Voc= 37 Vmp= 29.5 V Record Low Temp: 13 Total voltage drop in AC conductors = 0.250/j. Isc= 8.54 A Max Average Hi Temp: 107 41.6667 Total voltage drop in AC and DC conductors = Imp= 7.97 A , I Tvoc= -0.1369 V/deg C Power -One Strings: ndividual MPP Tisc= 1 5.124 mA/deg C 1 String Type A and 2 Combined Strings Type A Voc Correction Method: Manuf Tvoc data Branch Circuit Type A 1 -way win; length: L 75 ft Power -One PVI -6000-S 11strings per branch 11 strings per branch 2 13 Yingli YL235P-29b Inverter Min Vdc Input: 90 Vdc 13 modules per series string 13 modules per series string Voc= 481 V Min Vmp at Max Temp: 320 Vdc Voc= 1 V 481 V Vmp= 383.5 V Max Voc at Min Temp: _ 544 Vdc Vmp= 383.5 V 383.5 V 8.54 A Inverter Max Vdc Input: 600 Vdc Isc= 8.54 A 8.54 A 7.97 A Max String Size: 14 Imp= 7.97 A 7.97 A 10.68 A Pq Art 690.8(AX1) 1 -way wire length: 35�ft Icont= 10.68 A 10.68 A Art 690.8(AX1) Conductor. C AWG 10 PV Wire 2.a Conductor 1:[D -AWG 08 THWN-2 Conductor 2:1D AWG 08 THWN-2 "[ Conductor 1: Conductor 2: (cont ' 1.25 = (Amps) 113.34 (cont ' 1.25 = (Amps) 13.34 13.34 30 deg C ampacity = i' 401 30 deg C ampacity = 55 SS (cont= (Amps) 3.34 2.b Icont= (Amps) 13. 13.3 Start ampacity 40 Start ampacity 5 55 Temperature derate (%=F) 10.41 Temp. derate (%=F) 0.41 0.41 Conduit fill derate (%_#) >*{ 1 Cndt. fill derate (%=#) 0. 0.8 Derated ampacity 6.40 Derated ampacity 1d. 18.04 Term 1 Term 2 1.c Icont*1.25= (Amps) 3.34 Temp table 75degC 75degC Ampacity 40 2.c Icont'1.25= (Amps) 13.34 13.34 {) r ! ±p Ampacity 50 50 1.d Icont' 1.25 = (Amps) lf3.34 2.d EGC C AWG 10 C AWG 10 Art. 250.122 OCP size = 15 OCP size 1 15 1 Inverter Type A Output Combined Inverter Output Power -One PVI 6000-S 1 -way wire length: 10 ft Service Voltage= 240 Volts Icont= 25.00 A F Art 690.8 AX1 Total Inverter Power -®1 Watts Icont = # of inverters*max inverter current 1 way wire length: EEft Art 690.8(A)(1) 3.a Icont '1.25 = (Amps) . 31.251 A Art 690.8(6X1) OCP size = `i�3S A Art. 240.6(A) Icont = (Amps) 42.50 3.b Conductor AWG 08 THWN-2 at 90 deg C: Table 310.15(BX16) 4.a Icont *1.25 = (Amps) 53.131A Art 690.8(B)(1) Icon( ' 1.25 = (Amps) '§91.25 OCP size = 601 A Art. 240.6(A) 30 deg C ampacity = 55 E 4.b Conductor E AWG 06 1.25 = (Amps) THWN-2 at 90 deg C: Table 53.13 310.15(6X16) 3.c Icont= (Amps) ,'25.00Icont' Start ampacity ' SS 30 deg C ampacity = 75 Temperature derate (%=F) 0.91 4.c lconl= (Amps) 42_.50 Conduit fill derate (%_#)', 0.8 Start ampacity 75 Derated ampacity ;40.04 Temp. derate (%=F) Cndt. fill dente (%_#) 0.91 1 3.d Icont*1.25= (Amps) 31.25 Ampacity -� 50 Derated ampacity 68.25 3.e EGC = C AWG 10 All. 250.122 4.d Icont*1.25= (Amps) 53.13. GEC = D AWG 08 All. 690.47, 250.166(B) Ampacity�T65 PRINISE OWNER AW La Quinta HARTMAN, SANDY -29b 77849 CALLE ARROBA LA QUINTA, CA 92253 7607774017 14 DESCRIPTION: HARTMAN RESIDENCE 10.81 kW ROOF MOUNT PV SYSTEM PAGE NAME-- ELECTRICAL AMEELECTRICAL CALCULATIONS DESIGN: Mike Fitch (650-963-5610) SHEET: REV. DALE: PV 11 A 2/22/201 SolarCi 3055 Clearview Way San Mateo, CA 94402 T:(650) 638-1028 I F:(650) 638-1029 (888) -SOL -CITY (765-2489) 1 www.solarcity.com CITY OF LA QUINTA LABELS BUILDING & SAFETY DEP1 PHOTOVOLTA WARNING[ ELECTRIC SHOO HAIARDI mw -APPROVED =`AOR CONSTRUCTION WWW.SOLAROntOM WARNING! ELECTRIC SHOCK HALIRDI (SM sawn WWW--ALAKm.COM PHOTOVOLTAIC OC DISCONNECT WARNINGI ELECTRIC SHOCK HAIARDI Vac V Vrnp V lac A Imp A �I la ��:SolarCity, WW1-w.51l0L AAan,ITC .coN YG E 23.5 YL235P•29b YL230P-29b SERIES I YL225P-29b YINGLISOLAR.COM I YingliAmericas PV MODULE a, I • e Offidoi Spordar of the 2010 RFA World Cup- Yngl Green Energy (NYSE:YGE) is one of the world's largest fully vertically integrated PV manufactvret�: CONFIDENTIAL — THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT SOLARCITY INC., NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE THE RECIPIENTS ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF SOLARCITY INC. Changing rhe Shope of POtvB/ General Specifications Outdoor Models PM-3.0.OUTD-US / PM-3.0-OUTO-S-US PYI-3.6-011TO-11S / PYI-3.6-011TO-S-US PYI-4.2.011TO-US / PVI-4.2-OUTO-S-US High -Efficiency, 3 kW to 4.2 kW Inverters Aurora® grid -tie transformerless inverters offer a unique combination of ultra-high efficiencies, installer -friendly designs, long service life, and competitive initial acquisition costs; significantly increasing return on investment in solar -power installations. Industry -Leading Features and Performance • High efficiencies deliver more energy— up to 96.60/6 (96% CEC). • Two inputs vrlth independent MPPTs, optimize power from multiple arrays oriented In different directions. • Compact size and high power density: 460OW max of output power in a box size of just 3311/16" x 1213!16" x 8114". Unmatched Applications flexibility • Full -fated power available up to 50 •C ambient temperature. • Two Input sections, with parallel option, with independent high-speed MPPTs, optimize energy harvesting from multiple arrays oriented in different directions. • Wide MPF? operating range: 90 to 580 VDC. Field -Proven Reliability • IP65 (NEMA 4) rated enclosure withstands the harshest environmental conditions. • Frord-mounted heat sink resists contamination, enhancing cooling and increasing reliability and long-term efficiency. • Grid -connected operation according to international standards, UL1741AEEE1547 & CSA -022.2 N.107.1.01. • 10 -year warranty, optionally extendable to 15 and 20 years. iB Nuam JB -922218 00 MARKET: MODULES RESI 46 ' YINGLI 4YL PRO,ECT MANAGER: MOUNTING SYSTEM: * HOLLAENDER PAYMENT TYPE INVERTER: LEASE Multiple Inverters INVERTER AURORA Photovoltaic Inverters Installer,Friendly t • Reverse -polarity protection minimizes potential damage caused by miswiring during installation. • Front -panel mounted LCD display provides real-time updates for all critical operating parameters. • RS -48.5 and USB communications Interfaces. • Integrated DC switch available in compliance with NEC Standard, Article 69D "Solar Photovoltaic System" (USA). • Anti-islanding protection. I Models AC Power PVI-3.0-OUTD-US 3000 W PVI-3.0.OUTO-S-US 3000 W PVI-3.6-OUTD-US 3600 W y PVI-3.6-OUTD-S-US 3600 W PVI-4.2-OUTD-US 4200 W PVI-4.2-OUTD-S-US 4200 W AURORA° Communicator software simplifies monitoring via PC. AURORA® Easy Control datalogger is available for remote control via Internet or modem. Renewable Energy Division lEMISE OYMER: MU La Quinta HARTMAN, SANDY 77849 CALLE ARROBA LA QUINTA, CA 92253 7607774017 , •d du b,W}at b denpe •Cpul mne -rgm,aera+.p rou<bsne.�m.uzbm.etranw HARTMAN RESIDENCE 10.81 kW ROOF MOUNT PV SYSTEM PAGE NAME CUTSHEETS Mike Fitch (650-963-5610) REV: DATE: PV 13 A 2/22/201 0 3055 Clearview Way San Mateo, CA 94402 T:(650) 638-1028 1 F:(650) 638-1029 (888)-SOL-CrY (765-2489) 1 www.solarcity.com CONFIDENTIAL — THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT SOLARCITY INC., NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE THE RECIPIENTS ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF SOLARCITY INC. General Specifications Outdoor Models PVI-5000-OUTD-US PVI-6000-OUTD-US High -Efficiency, MW to 6kW Inverters Aurorae grid -tie transforrnedess inverters offer a unique combination of ultra-high efficiencies, installer -friendly designs, long service fife, and competitive initial acquisition costs; significantly Increasing return on investment in solar -power installations. Industry -Leading features and Performance • High efficiencies deliver more energy — up to 97% (96,5 CEC). • Two inputs with independent MPPTs, optimize power from multiple arrays oriented in different directions. • Compact size and high power density: 6000W max of output power in a box Just 38 5/8" x 1213/16 x 711/16" Unmatched Applications Flexibility • Full -rated power available up to 50•C ambient temperature. • Dual input sections with parallel option, with independent high-speed MPPTs, optimize energy harvesting from multiple arrays oriented in different directions. • Wide MPPT operating range: 90 to 580VDC Field -Proven Reliability • IP65 (NEMA 4) rated enclosure withstands the harshest environmental conditions. • Front -mounted heat sink resists contamination, enhancing tooling and increasing reliability and long-term efficiency. • Grid -connected operation according to international standards, UL1741BEEE1547 & CSA -022.2 N.107.1-01 • Ten-year warranty, optionally extendable to fifteen and twenty years. ,oB NumBER JB -922218 00 MARKET: I NODULES O,ECT MANAGER: MOUNTING SYSREM: * HOLLAENDER YMENT TYPE: INVERTER LEASE Multiple Inverters INVERTER AURORA Installer Friendly • Reverse -polarity protection minimizes potential damage caused by miswiring during installation. • Front -panel mounted LCD display provides real-time updates for all critical operating parameters. • RS -485 and USB communications interfaces. • Integrated DC switch available in compliance with NEC Standard, Article 690 "Solar Photovoltaic System" (USA) • Anti-islanding protection PREMISE MM AIU La Quinta HARTMAN, SANDY 77849 CALLE ARROBA LA QUINTA, CA 92253 7607774017 Changing The Shape of Power AURORA Photovoltaic Inverter SPECIFICATIONSrrl INPUT PARAMETERS OC 81de / ,rrr r r Nominal DC Power k 5.15 6.18 Total Max. Recommended DC Power fkW1 5.3 6.4 Operating MPPT Input VoftaQe Range M 90 to 580 360 nominal Full Power MPPT Range M 140.530 170-530 Max. Input Voltage M 600 Activation Voltage M 200 nominal ad'ustable within 120-350 No Of IndeDendent MPPT Trackers 2 Max. Input Power Each MPPT W 4 4 No. Of DC Inputs 2 1 each MP 2 1 each MP Max. DC Current Each MPPT A 18 22 short circum 18 22 short dreult Thermally Protected DC Side Varislor 4 2 for each MPPTj DC Switch Integrated Fiatin : 600Vdc125A DC Connectlorns 4 (2 POSITIVE, 2 NEGATIVE) SCREW TERMINAL BLOCK 3 KNOCK -OUTS: G1&1/2' or G1' (using ring reduction) CONDUCTOR CROSS SECTION: MAX AWG4 OUTPUT PARAMETERS AC Side Nominal AC Power 5000 6000 Max. AC Power fkWl 5000 6000 C Grid Connection single phase / split phase Nominal AC Voltage Range M Detaun : 240V split phase Optional :208 or 277 single phase(setting required) Maxfnwm AC Voltage Range M 187.2-224.6.216.2592 a 249.3-299.2 Nominal AC Frequency z 60 Max. AC Line Current[Al24.2018 30 short circuit 294 25.21.6 30 short circuit C Side Varistor 2 Uve - Neutral / Live - PE AC Connection SCREW TERMINAL BLOCK 3 KNOCK -OUTS: G1&1/2" or Gt' (using ring reduction) CONDUCTOR CROSS SECTION: AWG4/8 Lina Paver Factor 1 AC Current Distortion D <2% at rated power with sine wave vottage Max. Efficiency 97% CEC Efficiency 96.5% Feed In Power Threshold 20 Niaht Time Consumption IWI < 2 Isolation Transformer -less EMVIRONMENTALPARAMETERs Cooling Natural cooling Ambient Temp. R °C -25 / + 60 r derailing above 50°C Operating Altitude Iftl 6.000 Acoustical Noise [dBA1 < 50 0 1 mt Environmental IP Rating IP65 Relative Humidity 0.100% oondensin MECHANICAL Dimensions HxWxD Inches 385/8-x1213M6'x711/16' Weight PbsI 66 OTHER Display YES (Alphanumeric 2 lines Communication RS485 (Spring terminal block - Conductor cross section: 0,08.1,5mmgrAWG28.16) USB connection (Service) 'Aurora Eas-Contror system for remote control (Optional) Standards and Codes Aurora Inverters comply with standards set for grid -tied operation, safety, and electromagnetic compatibility including: UL1741AEEE1547 & CSA -022.2 N.107.1-01, VDE0126, CEI 11-20, DK5940, CEI64-8, IEC 61683, IEC 61727, EN50081, EN50082, EN61000, CE certification, EI Real Decreto RD1663/20DO de Espaiia. HARTMAN RESIDENCE 10.81 kW ROOF MOUNT PV SYSTEM PAGE NAME: CUTSHEETS DESGN: Mike Fitch (650-963-5610) SHEET: REV. DATE- PV ATEPV 14 A 2/22/201 iarCi 3055 Clearview Way San Mateo, CA 94402 7:(650)638-1028 1 F:(650) 638-1029 (888)-SOL-CrY(765-2489) 1 www.solarcity.com PIPE FITTINGS foil nam , Witw lillon*A Certificate of Compliance The Hollaender Mfg. Co. hereby certifies that the products listed below are routinely supplied by our company and meet or exceed all requirements of the following specifications: i Product: Speed -Rail®, Nu -Rail® and Interna -Rail® as manufactured by The Hollaender Manufacturing Co, t Metal: Fittings cast of aluminum alloy 535. Aluminum ingot complies with ASTM B 179. Product cast in accordance with ASTM B26. Set Screw: Forged knurl cup point set screw with class 3A threads. Set screw complies with ANSI/ASME B 18.3 & FF -S-200. Zinc plated, alloy steel set screws comply with ASTM F912 and JS - 600. Austenitic stainless steel set screws are 302 alloy. Testing: Structural tests have been performed on Hollaender handrail systems and individual components by certified independent laboratories including Space Dynamics Research Corp., Belcan, Pittsburgh Testing Laboratories, H.C. Nutting, and University of Dayton Research Institute. - I Design: Structural fittings, when properly installed per manufacturer recommendations, meet or exceed all applicable requirements as specified by OSHA, BOCA, SBC and UBC. All products supplied by the Hollaender Mfg. Co. are manufactured completely in the United States of America. Call Toll Free: 800-772-8800 www.hollnender.cont "The Fitting with the Alb "® Copyright 2001 The Hollaender Manufacturing Company ) P.O. Box 156399, 10285 Wayne Avenue, Cincinnati, Ohio 45215-6399, Fax: 800-772-8806 1 ,IiDtltr imndratl Sotctr& Chemical Composition Limits per ASTM B 26-98 Si Fe Cu M nM g Ti Other All 0.15 0.15 0.05 0.10-0.25 6:2-7.5 0.01-0.25 0.15 Remainder Typical Mechanical Properties Temper Ultimate Yield Elongation Shear Compressive Brinell Endurance Strength Strength Stren th Yield Strength Hardness Limit (ksif (ksij (% in 2 In.) (ksi� (ksi) Iksi) F 40 20 13 27.45 23.5 70 10 (35 min.) 118 min.) 19 min.) (70 min.) ASfMB2ii88 • Thermal Conductivity (6 77F, SI units): 0.24 cal/cm•s•K. • Heat Treatment - Achieves its physical and mechanical properties as -cast (F). This eliminates the time and cost of heat treating. • Machinability -,Excellent machinability as -cast, excellent surface finish, and high dimensional stability. • Corrosion Resistance - Highest of any cast alloy. It can be anodized for additional corrosion protection to a 0.7 mil thickness (2151111. • Finishing - Produces an excellent surface finish by burnishing or polishing. Anodizes well to a clear -satin finish due to the minimal amount of silicon in the alloy. • Weldability - It can be welded by any of the inert gas processes. T.I.G. or M.I.G., using filler rod of 5356 or 5183. Load Capacity of Fitting Set Screws When Pro perlyTorqued Std. IPS Size Steel Pipe Schedule 40 Aluminum IPS Size Pipe Schedule 40 Fitting Torque No. Push Fitting Torqque No. Push Size FL Lbs. Screws Out Size Ft. a. Screws Out 3/4' 13 1 1C60Did. 1-1/4' 10 1 937 lbs. 13 2 1900 lbs. 10 2 1006lbs. 1' 14 1 1200 lbs. 1-1/2' 12 1 9501bs. Above data. -piled try au iodepen deet laboratory using tha fdloving test pecedumr. Slanda d LF..S: sued pipe within the vertical bevel ol the tea linings• to the tontine shawe above, A 30.0001b Universal Testing Medina applied ren®l load to the pipe member in ao attempt to produce pipe slippage. Load capacities bard above ere rased an a salety Fath of 2:1. 12 2. 1020Ibs. Above data compiled by an in l epeedent laboratory using the forming prucedow.. A 30.000 lb. Universal Testing Mwbina applied venical load to the pipe member in an etlempt Io produce pipe slippage thmngb the venial barrel al the linin. Load capeskin listed above are tassel on a safely Wor of 100%. Call Toll Free: 800.172.8800 • www.holloonder.corn - Copyright 2001 Hollaender h JB -922218 0 0 14 2 1800 Its. 1-1/4' 17 1 1og0Or, 17 2 20001bs. 1.1/2' 17 1 1850 lbs. 17 2 2350Ibs. 2' 17 1 1925 am 17 2 3200 Un Above data. -piled try au iodepen deet laboratory using tha fdloving test pecedumr. Slanda d LF..S: sued pipe within the vertical bevel ol the tea linings• to the tontine shawe above, A 30.0001b Universal Testing Medina applied ren®l load to the pipe member in ao attempt to produce pipe slippage. Load capacities bard above ere rased an a salety Fath of 2:1. 12 2. 1020Ibs. Above data compiled by an in l epeedent laboratory using the forming prucedow.. A 30.000 lb. Universal Testing Mwbina applied venical load to the pipe member in an etlempt Io produce pipe slippage thmngb the venial barrel al the linin. Load capeskin listed above are tassel on a safely Wor of 100%. Call Toll Free: 800.172.8800 • www.holloonder.corn - Copyright 2001 Hollaender h JB -922218 0 0 CONFIDENTIAL A THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT SOLARCITY INC., NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART IZ OTHERS C PT IN THE RECIPIENTS ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF SOLARCITY INC. ae NUMBERHARTMAN, PREMISE oYMER: AKI: La Quints DESCRIPTION: SANDY HARTMAN RESIDENCE 77849 CALLE ARROBA 10.81 kW ROOF MOUNT PV SYSTEM LA QUINTA, CA 92253 i PAGE NAME 7607774017 h CUTSHEETS DESIGN: Mike Fitch 650-963-5610 ( )� �' �e1b Of� I�� MARKET: RESI MODULES 46 YINGLI YL235P-29b PRQECT MANAGER: MOUNTING SYSTEM: HOLLAENDER 3055 Clearview Way San Mateo, CA 94402 7:(650) 638-1028 I F:(650) 630.1029 (888) -SOL -Ceti' (765-2489) (www.solarcity.can SHEET; REV6 DATE; PV 15 A 2/22 2012 PAYMENT TYPE LEASE INVERTER Multiple Inverters CONFIDENTIAL - THE INFORMATION HEREIN JOB NUMBER JB -922218 CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MAR(E7. MODULES NOR SHALL IT BE DISCLOSED IN WHOLE OR IN RESI 46 YIP PART TO OTHERS OU19DE THE RECIPIENTS --- Amparo Rating ---- ---- -------------- I itches NEMA 1 Enclosure Indoor NEMA 3R Enclosure Rainproof January 2001 I I 120V 7AOV 240V MOV, Val. 1, Ref. No. 102421 I I 121DI240V AC General Duty, Fusible, and Non -Fusible, Single Throw 1 Price Number U.S. S I I 120/240V AC General Duty, Fusible, Single Throw Number U.S. a Number Mrs100 Table E-311, 12DJ24DV AC General Duty, Fusible, Single Tbrow 100 IT60 I H — 314.00 DG923URB0 630.00 200 I I 400 H — — 50-126 — I I DG=FRK0 2A75.00 125 600 H — — 1 I DG32WGK0 3,680.00 DG326MK0 6,020.00 — 600 H i 3 -Pale 3 -wire (Three Blades, Three Fuses)— 240V AC 75-200 — DG326NGK System I I 30 H — /-1/2-3 3-7-1/2 — D0321NG8 128.00 DG321NRB 192.00 b n 15 200 H — 15 25-5015— D �K 85.00 DG324NRK 980.00 400 H — — 50-125 — D6325<IGK2,090.00 DG325 Amparo Rating Fuse Type Provision Maximum Horsepower Rettrtga O NEMA 1 Enclosure Indoor NEMA 3R Enclosure Rainproof 1�haas AC 9 -Phase AC OC 120V 7AOV 240V MOV, Catalog Prke Catalog Prlee Price Number U.S. S Number U.S. a Number Mrs100 I 1-VIiue (three Bladen, Three Fuses, SRI)—120/LPoV AC - I I I I I I O WARNING! Swkch is not approved for service entrance unless s neutral kit Is Installed. I I O Drilled to accept field Installed neutral kits. I � O Use 3 -wire catalog numbers below. � I I I I I I I Discount 1 I Symbol ........................22 -CD 1 I 1 tTD� For more information contact Cutler -Hammer at: www.cb.cutler-hammercotNcatalog CAT.200.0 I O Maximum hp ratings apply only when dual element fuses are used. 1 I O Solid neutral bars are not Included in 400A and 600A switches. Order separately from table on Page Sd. I I O Use 4 -wire catalog numbers below. I ! 120R40Y AC General Duty, Non -Fusible, Single Thro 3D H H Number U.S. S Price Number U.S. S 100 IT60 2W H — 314.00 DG923URB0 630.00 200 — I 400 H — — 50-126 — D0325FGK0 2,020.00 DG=FRK0 2A75.00 125 600 H — — 76-200 — DG32WGK0 3,680.00 DG326MK0 6,020.00 I 1-VIiue (three Bladen, Three Fuses, SRI)—120/LPoV AC - I I I I I I O WARNING! Swkch is not approved for service entrance unless s neutral kit Is Installed. I I O Drilled to accept field Installed neutral kits. I � O Use 3 -wire catalog numbers below. � I I I I I I I Discount 1 I Symbol ........................22 -CD 1 I 1 tTD� For more information contact Cutler -Hammer at: www.cb.cutler-hammercotNcatalog CAT.200.0 I O Maximum hp ratings apply only when dual element fuses are used. 1 I O Solid neutral bars are not Included in 400A and 600A switches. Order separately from table on Page Sd. I I O Use 4 -wire catalog numbers below. I ! 120R40Y AC General Duty, Non -Fusible, Single Thro Number U.S. S Price Number U.S. S 100 — 16 30 — 314.00 DG923URB0 630.00 200 — 15 60 — OG92AUGK0 665.00 DG324URK0 955.00 400 — — 125 — D(i325UGK0 1A60.00 pG325URK0 2,260.00 600 — NRK 2,555.00 — 600 H — — 75-200 — DG326NGK 3,825.00 DG326NRK 6,310.00 row System Amparo Maximum Horsepower Ratings NEMA 1 Enclosure NEMA 3R Ertdoauro Rating 1•Phase AC 3-0Aase AC DC Indoor Relnproo! 120V 240V 210V 250V Catalog Price Catalog w ! nmrrtnrsre mole 2 -Wire Rwo Bladed —2104 AC �31 — 3 — — DG221UGB0 93.60 DG221UR80 124.00 60 _ 10 DG222UGB0 120.00 0G722UR60 225.00 4 100 15 DG213UGB0 251.00 DG223UR60 303.00 200 —0 Number U.S. S Price Number U.S. S nmrrtnrsre mole 2 -Wire Rwo Bladed —2104 AC �31 — 3 — — DG221UGB0 93.60 DG221UR80 124.00 60 _ 10 DG222UGB0 120.00 0G722UR60 225.00 4 100 15 DG213UGB0 251.00 DG223UR60 303.00 200 —0 3 -mere 3.wae r r arae nreeesr —xsrw aL 30 — 3 7-,R — oG3z,ucso ,os.00 Dr,3swNBo 191.00 100 — 16 30 — 3 -mere 3.wae r r arae nreeesr —xsrw aL 30 — 3 7-,R — oG3z,ucso ,os.00 Dr,3swNBo 191.00 1.T.E I I I I I I I I I 00 PREMISE OWNER: AHJ: La Qulnta DESCRIP110N: HARTMAN, SANDY HARTMAN RESIDENCE LI YL235P-29b 77849 CALLE ARROBA 10.81 kW ROOF MOUNT PV SYSTEM ORGANIZATION, EXCEPT IN CONNECTION WITH PROJECT MANAGER MOUNTING SYSTEM: LA QUINTA, CA 92253 THE SALE AND USE OF THE RESPECTIVE * � , ` HOLLAENDER PACE NAME SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PAYMENT TYPE: INVERTER PERMISSION OF SOLAROTY INC. LEASE Multiple Inverters 7607774017 CUTSHEETS Mike Fitch (650-963-5610) SHEET: REN 'DATE- PV ATE PV 16 A 2/22/201 ��=�So1arCi ty 3055 Clearview Way San Mateo, CA 94402 7:(650)638-1028 I F:(650) 638-1029 (888}SOL{ITy (765-2489) 1 www.solartaty.cam DG321NTU1 Table 837.120240Y AC General Duty. Nos-Fusihle. Sirwle Th 100 — 16 30 — DG823UGB0 314.00 DG923URB0 630.00 200 — 15 60 — OG92AUGK0 665.00 DG324URK0 955.00 400 — — 125 — D(i325UGK0 1A60.00 pG325URK0 2,260.00 600 — — 200 — D0926UOKOO 2,770.00 DG926URK0 4,150.00 1.T.E I I I I I I I I I 00 PREMISE OWNER: AHJ: La Qulnta DESCRIP110N: HARTMAN, SANDY HARTMAN RESIDENCE LI YL235P-29b 77849 CALLE ARROBA 10.81 kW ROOF MOUNT PV SYSTEM ORGANIZATION, EXCEPT IN CONNECTION WITH PROJECT MANAGER MOUNTING SYSTEM: LA QUINTA, CA 92253 THE SALE AND USE OF THE RESPECTIVE * � , ` HOLLAENDER PACE NAME SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PAYMENT TYPE: INVERTER PERMISSION OF SOLAROTY INC. LEASE Multiple Inverters 7607774017 CUTSHEETS Mike Fitch (650-963-5610) SHEET: REN 'DATE- PV ATE PV 16 A 2/22/201 ��=�So1arCi ty 3055 Clearview Way San Mateo, CA 94402 7:(650)638-1028 I F:(650) 638-1029 (888}SOL{ITy (765-2489) 1 www.solartaty.cam DG321NTU1 Table 837.120240Y AC General Duty. Nos-Fusihle. Sirwle Th