Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
BSOL2014-0025
A 78-495 CALLE TAMPICO VOICE (760) 777-7125 LA QUINTA, CALIFORNIA 92253 FAX (760) 777-7011 COMMUNITY DEVELOPMENT DEPARTMENT INSPECTIONS (760) 777-7153 BUILDING PERMIT Date: 11/12/2014 Application Number: BSOL2014-0025 Owner: Property Address: 81721 HIDDEN LINKS DR HERBERT NAGEL APN: 767640045 81721 HIDDEN LINKS DR Application Description: 9.35kW PV SYSTEM -(34) 275W PAN+M250 INV/100A SUB/225A SERV LA QUINTA, CA 0 Property Zoning: Application Valuation: $65,000.00 Applicant: SOL FUSION INC 20750 VENTURA BLVD STE 430 WOODLAND HILLS, CA 91364 NOV 12 2014 CITY OF LA QUINTA COMMUNITY DEVELOPMENT DEPARTMENT LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, and my License is in full force and effect. License Class: B. CIO License No.: 980873 fl Date: J400 1Dlti —Contractor: OWNER -BUILDER DECLARATION hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Divisi 3 of the Business and Professions Code) or that he or she is exempt therefrom and th basis for the alleged exemption. Any violation of Section 7031.5 by any applicant f r a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: ( ) I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself of herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). (_) I, as owner of the property, am exclusively contracting with licensed contractors to construct the project. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). ( I I am exempt under Sec. . B.&P.C. for this reason Date: Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Lender's Address: Contractor: SOL FUSION INC 20750 VENTURA BLVD STE 430 WOODLAND HILLS, CA 91364 (855)765-3874 Llc. No.: 980873 WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: I have and will maintain a certificate of consent to self -insure for workers' Z29pensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier: _ Polity Number: _ I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, if I shout su sectto t e workers' compensation provisions of Section 3700 a Labor Code, I shall forthwith Comply with those provisions. C ��� IV0110 ?,Yl Applicant: WARNING: FAILURE TO SE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN' MPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT: Application is hereby made to the Building Official for a permit subject to the conditions and restrictions set forth on this application. 1. Each person upon whose behalf this application is made, each person at whose request and for. whose benefit work is performed under or pursuant to any permit issued as a result of this application , the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents, and employees for any actor omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter Jnentioned property for inspection purposes.' Date: NIOs'� Signature (Applicant or Agen e• r.'�`;;�:J�»�Esrraz�,. .,�+�,de°,?'�*X34.:. ESCRIF4T10N'��� is ACCOUNTrs" TY �<,'i41VI0UNTF Pi41Dti'a Pi41U''`DATE �.. ,k- ..s.H..�c,.".:. .. �„*�.•::„i n...F..:,s...rt-y. .—:.¢Q<,.. BSAS SB1473 FEE 101-0000-20306 0 $3.00 : $0.00 �;�;PAIR:B�Y� ,-`��",� �,��� � METHOD`s`�'�' `"•�; �` �'��RECEIPT;€#> .� � t� , x� � r� �� rF� ���, _ �� <� , : �'; ;<,��a ._, .�. �.�f� _......�.�� :<.._,�_ , ..a� ,x�. _..x..<��' � u .,� :<y. Yom. ��:x�..��.: � �� �.�.._,�,P.: �, �w zw :� ���.P,,� HECK _b �.� � ��.:E� _�,_.��,� #�� • �CLTD BYE Total Paid for BUILDING STANDARDS ADMINISTRATION BSA $3.00 $0.00 �t L a<.._ ., �,n �Y;..YzF_%3v.i. �,'i;�4:�i. ,�h�R ..,.w3a agf"�� �:C :'F.€`S � :fi�klT�,F^�u.s.....<a ' n^•.f , j.S.:n"hi ...u�.d �1.. h•�'A !u �.. ���mKz�Y4�s'3&' .u(! C J64tw. ai �� 'XLH �� Sd,i. 3: e ti'.�ae..Swu xf... ,Yi'. Y.ki $G`.n.s?'>`^° +.d/#"a PV"SYSTEM - ARRAY, FIRST 20 101-0000-42403 0 $24.17 $0.00 :�X sdr�.:.Ev N�,�•' Fy'y ;ty YLG "'YE..�M ID;fY v; •,1�2 3,> �:E. °.� �<,��. ?.,@�.� .�..�>&P,fA�, ;B„� � ,$<..: I YkC 1R.4L.—T:D.- agsin ' :a„y_ :� `Kt ...�. ° , R'��{ '�Nti.� �; r DESCRIPTION;, 4b•M �� � tS k � rc �t r „s,-'4:, (QTl(-AMOUNT�E' �� `Y.? .9' z': �i_ PAID x PAIDDATE ,, . ,;�' c._-'."z'•o-.;a; ktS" g`ACCQUNT, ..,. %e xlK'arc.4F,.'r`�.?Ra'u?n"��.'Pdi:D:. PV SYSTEM - ARRAY,'FIRST 20 PC 101-0000=42600 0 $24.17 $0.00 -- ��,.} 3�,f � >y Y�.:: i1la. 'g f*R '...3'Ti"e'.:�'.,4v�Y,� Wsv3 `v°3+�Fy �'h f� �. .-�.:. ,'..�'�3 � � E Z t.. �:. zCS$��"'� 'f`��.. :.: 1!' ;•f'� Y. B Se �r?r OWN � f DESCRIPTION` .wh.�� '-. 'PV SYSTEM - MISC EQUIPMENT , 101-000042403 0 $48.34 $0.00 # '�� Y BOOM, st. �Zi BY:,� ..< ., a< Ea..<.o—u'a:acz ."�'f •: 2.�4�ro 1«6 �6=.-S. ,�...�. ...!'.1-.-, g METHOD .N.r��i$b.a.,.. .h�..,.:_.,,u, »„'a #c...e��. '..�'...'�_4. °:RECEIPT#' CHECK # CLTD BY r c.` X 4 z � ✓# S” a ::a *, ° k � dP” ' , � � ' t ,�� sz s .�..'£'�i" s 'S �r t ,�;:z_,,' x PV,SYSTEM - MISC EQUIPMENT PC -. .101-0000-42600 0 $48.34 $0.00 PAID BY �q, r.,.�.: Y...,:�s.::<.,,. .�s METHOD RECEIPT #� ,�.mk ir:�s.;: st, . <<;CHECK f'64YE' N11alA,=':iLs4..r,. �. Total "Paid,forELECTRICAL: $145.02 $0.00 a , s DESCRIPTION E �, ACCOUNTS h { `r PAIED',DATE.. y„. n fi :°4 AMOUNTS PERMIT ISSUANCE 101-0000-42404 0: $91.85 $0.00 , f w< <...w ' ECEIPT�# .. EY.y�.d"_: iCLTD BY p ...,, , Total Paid forPERMIT ISSUANCE:. $91.85 $0.00 Description: 9.35kW PV SYSTEM -(34) 275W PAN+M250 INV/100A SUB/225A SERV Type: SOLAR • Subtype: Status: APPROVED Applied: 10/2/2014 PJU Approved: 11/10/2014 JFU Parcel No: 767640045 Site Address: 81721 HIDDEN LINKS DR LA QUINTA,CA 92253 Subdivision: TR 31202-2 Block: Lot: 33 Issued: Lot Sq Ft: 0 Building Sq Ft: 0 Zoning: Finaled: Valuation: $65,000.00 Occupancy Type: Construction Type: Expired: No. Buildings: 0 No. Stories: 0 No. Unites: 0 Details: 9.35kW SOLAR ARRAY - (34) 275W SUN EDISON PANELS + M250 EN PHASE MICROINVERTERS/100A SUBPANEL/225A SERVICE CHANGEOUT [612SF] 2013 CALIFORNIA ELECTRICAL CODE. ADDITIONAL SITES CHRONOLOGY TYPE' -. STAFF NAME CHRONOLOGY ACTION DATE COMPLETION DATE NOTES E-MAIL JAKE FUSON 10/29/2014 10/29/2014 EMAILED BERNARDO CASTRO 2ND REVIEW CORRECTIONS AND REDLINED PLANS. SENT 3RD CORRECTION LIST AND REDLINES TO BERNARDO E-MAIL JAKE FUSON 11/3/2014 11/3/2014 CASTRO WITH SOL FUSION AT Bernardo@solfusion.net E-MAIL JAKE FUSON 11/6/2014 11/6/2014 EMAILED CORRECTIONS TO BERNARDO CASTRO WITH SOL FUSION AT Bernardo@solfusion.net CALLED APPLICANT BERNARDO CASTRO AND NOTIFIED HIM TELEPHONE CALL JAKE FUSON 11/10/2014 11/10/2014 PLANS WERE APPROVED AND PERMIT WAS READY TO BE ISSUED. Printed: Wednesday, November 12, 2014 11:18:18 AM 1 of 3 4sa' F, SYSTEnAS Printed: Wednesday, November 12, 2014 11:18:18 AM 2 of 3 SYSTEMS • FINANCIAL•• EMAIL c NAME TYPE NAME ADDRESSI . CONTACTS CITY STATE ZIP PHONE FAX .:, APPLICANT SOL FUSION INC 20750 VENTURA BLVD WOODLAND HILLS CA 91364 $3.00 $0.00 CONTRACTOR SOL FUSION INC 20750 VENTURA BLVD WOODLAND HILLS CA 91364 $24.17 $0.00 OWNER HERBERT NAGEL 81721 HIDDEN LINKS DR LA QUINTA CA 0 Printed: Wednesday, November 12, 2014 11:18:18 AM 2 of 3 SYSTEMS • FINANCIAL•• CLTD DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE RECEIPT # CHECK # METHOD PAID BY BY: BSAS SB1473 FEE 101-0000-20306 0 $3.00 $0.00 Total Paid forBUILDING STANDARDS ADMINISTRATION $3.00 $0.00 BSA: PV SYSTEM - ARRAY, 101-0000-42403 0 $24.17 $0.00 FIRST 20 PV SYSTEM - ARRAY, 101-0000-42600 0 $24.17 $0.00 FIRST 20 PC PV SYSTEM - MISC 101-0000-42403 0 $48.34 $0.00 EQUIPMENT , PV SYSTEM - MISC 101-0000-42600 0 $48.34 $0.00 EQUIPMENT PC Total Paid forELECTRICAL: $145.02 $0.00 PERMIT ISSUANCE 101-0000-42404 1 0 $91.85 $0.00 Total Paid for PERMIT ISSUANCE: $91.85 $0.00 TOTALS:00 Printed: Wednesday, November 12, 2014 11:18:18 AM 2 of 3 SYSTEMS ISOLAR FINAL" I I BOND INFORMATION SUBDIR ETRAKIT ENABLED Attachment Type CREATED OWNER ATTACHMENTS DESCRIPTION REMARKS - NOTES REVIEW TYPE REVIEWER SENT DATE DUE DATE RETURNED .DATE REVIEWS STATUS NON-STRUCTURAL AJ ORTEGA 10/2/2014 10/9/2014 10/28/2014 REVISIONS REQUIRED COMMENTS.pdf NON-STRUCTURAL JAKE FUSON 10/28/2014 10/29/2014 10/29/2014 REVISIONS REQUIRED SEE ATTACHED REVIEW. NON-STRUCTURAL JAKE FUSON 11/3/2014 11/10/2014 11/3/2014 REVISIONS REQUIRED SEE ATTACHED REVIEW. NON-STRUCTURAL JAKE FUSON 11/6/2014 11/13/2014 11/6/2014 REVISIONS REQUIRED NON-STRUCTURAL JAKE FUSON 11/10/2014 11/10/2014 11/10/2014 APPROVED 11/3/2014 JAKE FUSON BOND INFORMATION SUBDIR ETRAKIT ENABLED Attachment Type CREATED OWNER ATTACHMENTS DESCRIPTION PATHNAME DOC 10/28/2014 JAKE FUSON SOLAR 1ST REVIEW SOLAR 1ST REVIEW 0 COMMENTS.pdf COMMENTS.pdf DOC 10/29/2014 JAKE FUSON SOLAR 2ND REVIEW SOLAR 2ND REVIEW 0 COMMENTS.pdf COMMENTS.pdf DOC 10/29/2014 JAKE FUSON SOLAR 2ND REVIEW SOLAR 2ND REVIEW 0 REDLINES.pdf REDLINES.pdf DOC 11/3/2014 JAKE FUSON SOLAR 3RD REVIEW SOLAR 3RD REVIEW 0 REDLINES.pdf REDLINES.pdf DOC 11/3/2014 JAKE FUSON SOLAR - 3RD REVIEW SOLAR - 3RD REVIEW 0 CORRECTIONS.pdf CORRECTIONS.pdf Printed: Wednesday, November 12, 2014 11:18:18 AM 3 of 3 C SYS7[MS AERIAL SITE PLAN SHEET INDEX: PV -0 Cover Sheet PV -4 Notes & Signage PV -8 Racking Specs PV -1 Photovoltaic Site Plan PV -5 Module Specs PV -9 Rail Specs N PV -2 PV Racking Details PV -6 Inverter Specs PV -10 Support Rail Calcs PV -3 Electrical Diagram PV -7 Inverter Specs PV -11 Grounding Specs PV -12 Directory Placard Detail PLANS TO COMPLY WITH ALL FOLLOWING CODES: A. 2013 California Building Code B. 2013 California Electrical Code C. 2013 California Residential Code D. 2013 California Fire Code PROJECT SUMMARY: SCOPE OF WORK: 20750 VENTURA BLVD. SUITE 431 Installation of a 9.35kW DC Roof -mounted photovoltaic system on WOODLAND HILLS, CA, 91364 existing single family dwelling. Proposed installation to compose of (34) P. 818.924.2485 275W Panels and new electrical components including inverter, dl ' I t and racking equipment as required. 0 SOL FUSION. FPROPERTY APN#: LICENSE NO. 980873 CL: B, C10 Tr %1 R. /rel'—T", 10/31/14 11DSIGNATUREDATE PV SYSTEM OUTPUT: 9.35kW DC / 8.14kW AC ` cO MODULE TYPE: LO E (34) SUN EDISON-F275CzC-3Y, PTC rating 248.1 N PV INVERTER: a) W j, (34) ENPHASE M250-60-2LL-S22-IG,CEC Eff. Rating 96.5% Q U U) ARRAY PLACEMENT: U Flush Mounted on 2nd Story Roof -�^ ARRAY TILT / AZIMUTH nU`� 1 Q Z z Al T C �e V� CO T� 13° Tilt / 86° Azimuth 13° Tilt / 266° AZ �^► ` VV�� 1 �/ DSP W ROOF TYPE: &5�� Pitched Concrete S Tile Roof �� U) `a PV ARRAY HEIGHT: ©A.� W � z Maximum 6" from top of roofing J Z INTERCONNECTION METHOD: Q I LO Interconnect via (N) 60A circuit breaker in (NEW) 225A Rated Panel(UPGRADE) _J C`3 Z W z a) O >_ M L GENERAL NOTES: Z w Q U 1. Solar photovoltaic system to be installed on existing Residential structure. Q o= U W r w m C C E 2. Design to comply with the latest edition of California Electrical Code, NEC, w W w m w N w � the applicable solar guidelines and all local ordinances and policies. o Z LW o r o `0 o j, 3. This project has been designed in accordance with CBC Section 1609 to a Z 2 a a C`3 Cn withstand a minimum 110 MPH wind load, Exposure C. 4. Existing house is 2 story(ies) tall. 5. Existing roof truss are 2 in. x 4 in. and 24 in on center. 6. This system will not be interconnected until approval from the local COVER jurisdiction and the utility are obtained. 7. This system is an utility interactive system with no storage batteries. SHEET 8. The solar photovoltaic installation shall not obstruct any plumbing, mechanical or building roof vents. 9. If the existing main service panel does not have verifiable grounding electrode, it is the contractors responsibility to install a supplemental REV DAq grounding electrode. 81 1DESCRIPTIONI 10. Each module will be grounded using the supplied connection points I I I I I I I , , , 1 , I 1 identified on the module and the manufactures installation instructions. 11. A ladder shall be in place for inspection in compliance with CAL -OSHA 11111 III A 11111111111111111 111111 regulations. 12. Proper access and working clearance will be provided per section 110.210 E 11/6/20) 13. All exterior conduit to be painted to mach existing exterior color. P 9 (A SCALE 111111111111111,11 1 N 14. Roof access points shall be provided per the following:1 11 w �1 BY I a. Located in areas not requiring placement of ground ladders over 1N openings such as door or windows. Q ANN b. Located at strong points of building construction in locations where N access point does not conflict with overhead obstructions such as tre� limbs, wires, or signs. PV=0 PROPERTY UNE N v O ", XX I 1T w m C/) N C 0 A A B B BfBJB BJB B - FA,-AtAtA A A A A fAf A A A t,A N�� �L8 38 0 o as =0 � =m a ao a s � m nm DO C- pp z P w 0<� r Z Om O O x cn r m DO m O m r Cl)m Cep m r- Dom n K DD M— - �� OCA -� ��� mw D z _ N Z D o n 0 77 n O np 0 �cNi, mm D =mn Oz 0c M m mw w �D no m XZ zz U) z r D x m 77 �� z < r0 = -A p -jmC M 0 O� m 0 � n C) 000 m DO D � O 0 0 z -o r m O a p m m 0 r m cn D <m m C) m Mr00 0 0 O _D Z Z PROJECT DECRIPTION: o (D W n 0 -o m ��C- z Grid Interactive - Negatively Grounded PV System °_; � r M m -a 0 D M O W 00 p System DC: 9.35kW / System AC: 8.14kW D D =D O m x w o m M Z N -� D z r o D 0 > C)< Z M 0 m � p p C7 O _ _ C7mmw r0 OZ w n r- � 1 O rn c`" C -)M Omcz Tc)cn� Z C7 = z j n 2C Op O n C p� Z M D D m p C Q D D Gi OC p -DI 77 Z C/)Z—� �77Z— D-10 a<0Km0 ZZmp� -Mm,�, z-nED OWN m--10 0�N m0� XM (M700 -� �mN _-0 N f T l N 77 — Ci p<N X77 < 0 O O mO 000 mp C�, 7j mm M -nM m� < m m M -1 O O Zcnz p=O D � > r- m D � Z -U mor pec m 00 nz O �' < D M Z M p m� pm D n Z= 0 D cn Z_ 2 C7 D D r r - r < 00 mm z U) :01 nmm1 Orrcn mC— n=cn C C — �: z 7o>0m D C p D ZCn Om0 zTpz O -I N 7� 0 77mrnv O � w 7J � O 00 .n 0 M C M r mm m� M' O D IE D 7 Z D D D D n n - T1 D 7 n 7 D -0 D =N D r =0 � =m = � < PROJECT NAME: cn �' r Cn n O m r m N of Cn z =m - - - - -- = N E G A L R E S I D E N C E _. �;- z m 00 _<_ _ _ _ _ > (A C mcn cD < rim 0 _ OWNER: 0 z 0 - M M 0 HERBERT NEGAL/ P: m= co M_ C _ = D 0 r D PROJECT ADDRESS: 000 -o r 81721 HIDDEN LINKS DR. LA QUINTA , CA 92253 W D o D _D _, = Z PROJECT DECRIPTION: o (D W =W D Grid Interactive - Negatively Grounded PV System °_; � m _z _° -c -> System DC: 9.35kW / System AC: 8.14kW m g o m o 1 1 1 PARTIAL ROOF PLAN SHOWING RACKING LAYOUT - 3/32" = 11-0'I MATERIAL LIST ITEM DESCRIPTION QTY FLUSH MOUNTED PV MODULE PROSOLAR TILE TRAC 6" ANCHOR AND FLASHING 4'-0" OC MAX 3❑ UNIRAC SM SUPPORT RAIL ®UNIRAC SPLICE BAR UNIRAC MID/END CLAMPS ©(E) PITCHED S TILE ROOF WITH (E) 2x4 TRUSS AT 24" O.C. NOTE: ROOF PENETRATION TO BE SECURE AND WATER TIGHT rol 12 1 TILE TRAC ATTACHMENT DETAIL- NTS PV MODULE, PER PLAN PROSOLA ASSEMBL UNIRAC SM /SUPPORT RAIL, TYP L BRACKET TYP (E) S TILE ROOF .i/16''x6" 1AG W/ 9.511 EMBED -H — — ----------- X --X -ti— - (E) SOLA' — — — WATER SUITE 430 WOODLAND HILLS, CA, 91364 P. 818.924.2485 SOL FUSION. MODULE SUN EDISON-F275CZC-3Y 34 INVERTER ENPHASE M250-60-2LL-S22-IG 34 STANCHION PROSOLAR TILE TRAC 6" 74 SUPPORT RAIL UNIRAC SM RAIL. SILVER, 168" 2n RAIL SPLICE SM SPLICE KIT, SILVER 8 MODULE CLAMP SM MID CLAMP, SILVER 48 SM END CLAMP, SILVER 32 U FLUSH MOUNTED PV MODULE PROSOLAR TILE TRAC 6" ANCHOR AND FLASHING 4'-0" OC MAX 3❑ UNIRAC SM SUPPORT RAIL ®UNIRAC SPLICE BAR UNIRAC MID/END CLAMPS ©(E) PITCHED S TILE ROOF WITH (E) 2x4 TRUSS AT 24" O.C. NOTE: ROOF PENETRATION TO BE SECURE AND WATER TIGHT rol 12 1 TILE TRAC ATTACHMENT DETAIL- NTS PV MODULE, PER PLAN PROSOLA ASSEMBL UNIRAC SM /SUPPORT RAIL, TYP L BRACKET TYP (E) S TILE ROOF .i/16''x6" 1AG W/ 9.511 EMBED -H — — ----------- X --X -ti— - (E) SOLA' — — — WATER (E) SOL WATER 1 3 1 PV ARRAY RACKING DETAIL - CUSTOM PROSOLAR TILE TRAC AND FLASHING. 4'-0" OC MAX (SEE DETAIL 2) PV MODULE, PER PLAN UNIRAC SM SUPPORT RAIL, TYP 20750 VENTURA BLVD. SUITE 430 WOODLAND HILLS, CA, 91364 P. 818.924.2485 SOL FUSION. L L- (E) SOL WATER 1 3 1 PV ARRAY RACKING DETAIL - CUSTOM PROSOLAR TILE TRAC AND FLASHING. 4'-0" OC MAX (SEE DETAIL 2) PV MODULE, PER PLAN UNIRAC SM SUPPORT RAIL, TYP 20750 VENTURA BLVD. SUITE 430 WOODLAND HILLS, CA, 91364 P. 818.924.2485 SOL FUSION. LCE N S E NO 9) 0.V 0.0 7 3) r^i . fl - V L. O, V I V 10/31/14 SIGNATURE DATE PV RACKING 130 TILT DETAILS 6"-, �— REV DESCRIPTION DATE 5/16"X6" LAG (E) 2x4 TRUSS W/ 2.5" EMBED AT 24" OC W/ 8' MAX SPAN DATE 11/3/2014 SCALE AS NOTED DRAWN BY AA PV -2 C7 E N � U) W Q (n U U - 0- Z H A� Z -0 ryT� 00 W ( U 7-3U o D Q E - C9) > >, cz W Y 0) -- Z z Ir J J z�� Q ! U-) J C3 z z Q) m C) L�jQ Z w a C3' fr o w z W In a o w w W w z w N -).- U) O � d z W0 o - r � 00 O i C3 ], c9) PV RACKING 130 TILT DETAILS 6"-, �— REV DESCRIPTION DATE 5/16"X6" LAG (E) 2x4 TRUSS W/ 2.5" EMBED AT 24" OC W/ 8' MAX SPAN DATE 11/3/2014 SCALE AS NOTED DRAWN BY AA PV -2 MODULE SPECIFICATIONS: INVERTER SPECIFICATIONV: ELECTRICAL NOTES: MODULE QTY 34 No. INVERTER QTY 34 No. 1. ALL WORK SHALL COMPLY WITH THE 2013 CBC, 2013 CEC, AND 2011 NEC WITH SPECIAL EMPHASIS ON ARTICLE 690 MANUFACTURER SUN EDISON MANUFACTURER ENPHASE 2. A SINGLE CONDUCTOR SHALL BE PERMITED TO BE USED TO PERFORM THE MULTIPLE FUNCTIONS OF DC GROUNDING, AC GROUNDING, AND BONDING BETWEEN AC AND MODULE TYPE SE-F275CZC-3y INVERTER TYPE M250-60-2LL-S22 DC SYSTEMS. AS PER NEC 690.47(C) ANS SIXED AS PER CEC. 250.122 20750 VENTURA BLVD. SUITE 430 MAX POWER OUTPUT (Pmax) 275Wp MAX INPUT DC VOLTAGE 48V 3. EQUIPMENT GROUND CONDUCTORS REQUIRED IN RACEWAYS SIZED PER CEC 250-122 OPERATING VOLTAGE (Vmp) 31.6V PEAK POWER VOLTAGE RANGE 27V -39V 4. PER ART 250.92, NON-CURRENT CARRYING METAL PARTS OF EQUIPMENT SHALL BE EFFECTIVELY BONDED TOGETHER. BOND BOTH ENDS OF RACEWAY. WOODLAND HILLS, CA, 91364 OPERATING CURRENT (Imp) 8.72A OPERATING RANGE 16V -48V 5. SOLAR BACKFEED BREAKER TO BE INSTALLED AT OPPOSITE END OF THE CIRCUIT OR FURTHEST AWAY FROM THE MAIN PER 690.64(B)(7). P. 818.924.2485 OPEN CIRCUIT VOLTAGE (Voc) 38.6V MAX DC SHORT CIRCUIT 15A 6. ALL EQUIPMENT TO BE UL LISTED FOR USE. SHORT CIRCUIT CURRENT (Isc) 9.28A MAX OUTPUT POWER 250W 7. CONDUIT TO RUN ALONG ROOF AND THEN DOWN THRU EAVE ALONG WALL TO PV INVERTER. MAX SERIES FUSE RATING 15A NOMINAL OUTPUT CURRENT 1.OA B. ALL LABELS AND MARKINGS SHALL BE ATTACHED PER NEC ARTICLES 690.5 (C), 690.14 (C)(2), 690.17,690.53,690.35(F), 690.54,690.64(B)(7) and 705.1 AND THE LOCAL AHJ. SOL FUSION. MAX SYSTEM VOLTAGE 600A NOMINAL VOLTAGE RANGE 211-264V 9. IF EXISTING MAIN SERVICE PANEL DOES NOT HAVE A VERIFIABLE GROUNDING ELECTRODE, IT IS THE PV CONTRACTOR'S RESPONSIBILITY TO INSTALL A SUPPLEMENTAL LICENSE NO. 980873 CL: B, C10 PTC RATING 248.1 CELL TYPE MONO MAX UNITS PER CIRCUIT 16 INVERTER EFFICIENCY 96.5% GROUNDING ELECTRODE. 10. ALL MODULES TO BE GROUNDED IN ACCORDANCE WITH CODE AND MANUFACTURE'S INSTALLATION INSTRUCTIONS. 10/31/14 XCo Copper er The calculation assumes uncoated copper or aluminum conductors operating at90 Cfor all cables and Is based on the AC resistance or Impedance from NEC 2013 Tables 8 and 9 for stranded conductors operating on for Nate: Voltage drop for ac systems g y� SIGNATURE l DATE E240] Phase Volts a 60Hz system. should total no ethan 5% under full load conditions. C0 LO E Length Distance Derate Factor Over Current Cable Conduit Conduit Design Add Usable Voltage Voltage General N VD Feeder Cables One Way off Roof (Table 310.16, Fill 0) Amp (A) Size Size Type Temp (0C) Factor (0C} Current Drop (V) Drop (014 Formula: U) (Ft} (in.) 310.15(B)(2)c w U >% > OK OK 1A 3 #10 THWN-2, 1 #8 THWN-2 GND 80 18.75 10 3/4" EMT 3.5" 50 17 0.58 1 23.2 3.72 1.55% 1 P = (I -R -L) / Vmax 2A (3)#10 7HWN-2, (1)#8 THWN-2 GND 80 10 10 3/4" EMT 3.5"' 50 17 0.58 1 23.2 1.98 0.83% OK OK U - 0 0 OK OK 3A (3) #10 THWN-2, (1) #8 7HWN-2 GND 5 13.75 10 3/4" EMT 3.5" 50 17 0.58 1 23.2 0.17 0.07%Z " OK OK Z 5A (3) #8 THWN-2, (1) #8 THWN-2 GND 5 42.5 6 3/4" EMT N/A 50 N/A 0.82 1 61.5 0.13 0.05% OK OK w � BRANCH CIRCUIT A: ® 4ACD (15) SUN EDISON F275 MODULE ® Q (� '^ U) UL 467 LISTED FOR OUTPUT VOLTAGE: 240Vac OUTPUT (BRANCH CIRCUITY �-/� w \ GROUNDINGAND BONDING _ _ -- 1.OA'15'1.25=18.75A J -BOX 30A AC DISCO. 30A AC DISCO. I Z7UL L]STED, SUITABLE FOR GROUNDING. NEMA 3 NEMA 3 NEMA 3 20A 2P -77 J LDIRECT BURIALAND CU CONDUCTORS �� � �� _ _ _- `" - - -` CONTINUOUS EQUIPMENT GROUND / \ CONTINUOUS AC GROUND WIRE Q � LO d$6A CU (INTEGRATED) 20A 2P Z Z M (TYP) EA MODULE I BRANCH CIRCUIT B: (11) SUN EDISON F275 MODULE 20A 2P Q 7 L W Q a AC CABLE (TYP) UL TYPE TC -ER FR-EPR/CPE (B) SUN EDISON 275W (8) ENPHASE M250 INVERTER (11) M-25060-240 MICRO INVERTER I \ ® o- waunsouRCE: MoOULEr. LLI < I� LU Q O � U i V^ IJ MULTICONDUCTOR CABLE, VOc(38.6V),114=44.O04V 2A Z O = W 600V UNSHIELDED, 90 DEGREE C RATED FOR B1 BZ Isc (s.28A)'t25=t1.6A OUTPUT (SOURCE: EA INVERTER): B8 { I O U w CO F T U U EXPOSED AND WET /DRY - - OUTPUT CURRE T51W / EA 60A 240V . I OUTPUT CURRENT51W ®O O -. 2P AC DISCONNECT -� W Z N _ to LOCATIONS. MEETS COLD OUTPUT VOLTAGE: 240Vac LOCKABLE, VISIBLE, OUTPUT CIRCUIT( I O W O r O 'i TEST AT -40 DEGREES C (BRANCH J-BOx 30A AC DISCO. NON FUSED *1.2DIN5= 10A Cr O- Z > O = D- CO 0- It O- V (4) #12 CABLES Ll, L2, N, G f f ({ NEMA 3 NEMA 3 I NEMA 3R 1. oU8 1 CONTINUOUS EQUIPMEN I GHUUND 17-1 CONTINUOUS AC GROUND WIRE _ _ _ CUE (INTEGRATED) OO ENPHASE MICOR INVERTERS Z I A`B CU EGC WITH INTEGRATED GROUND. NEC COMPLIANT (11) SUN EDISON 275W _ (NEW) 225A RATED NG 20 A iPH, 3W BRANCH CIRCUIT 27 #8 IRREVERSIBLE CRIMP �^ I (TO REPLACE EXISTING 200A CENTERFED NON CENTER FED PANEL) (11) SUN EDISON F275 MODULE ELECTRICAL UNGROUNDED PV POWER (11) ENPHASE M250 INVERTER (11) M-25060.240 MICRO INVERTER F SYSTEM (690.35, 690.41) (TYP) -. _ Cl Cit INPUT (SOURCE: MODULE), _ I von (38.6V) • 1 14 44.004V I. (928A)'125 t16A C11 F I ,M (E) LOADS O DIAGRAM OUTPUT (SOURCE. EA INVERTER) O I `� 'j OUTPUT POWER: 250W/EA o: I ` / I (N) OUTPUT CURRENT: 1.OA / EA ®® I �O 200A (Yddd/A0q /EEp �LL� / zPA (\ (\ OUTPUT VOLTAGE:240Vac _ J BOX CY . C C OUTPUT (BRANCH CIRCUIT(. - 2P I NEMA 3 I NG. GROUN I ND _� - 225A RATED BUS I REV DESCRIPTION DATE NOTE: $-BAIF U CONTINDUIOUS AOC GRMUND WIRE 1PV WIRING IS TO BE TAGGED AND IDENTIFIED AT EACH END AND AT INTERMEDIATE CONNECTIONS AND SPLICES. (INTEGRATED) o 3.PHOTOVOLTAIC SYSTEM CONDUCTORS SHALL BE IDENTIFIED AND GROUPED. THE MEANS OF IDENTIFICATION SHALL BE PERMITTED BY SEPARATE COLOR CODING, I (N) ADDITIONAL GROUND (E) SERVICE GROUND ® 3A MARKING TAPE, TAGGING, OR OTHER APPROVED MEANS. THE MEANS OF GROUPING SHALL BE WIRE TIES OR SIMILAR MEANS AT LEAST ONCE, AND THEN AT I ROD 6' MIN IF REQUIRED TO IID INTERVALS NOT TO EXCEED (6) FEET. (CEC690.4(B)) _ P T L C U EA S T A O T i D T O E O S I T Y E N C 6 4 DATE, 1 6/2014 REQUIRED MARKINGS AND LABELS LOCATIONMAIN LOCATION: ON AD DISCONNECT LOCATION ON EACH JUNCTION BOX, COMBINER BOX, LOCATION: MSP TEXT SIZE: 3 / B" MIN. NON BOLD TEXT SIZE 14 PTSNONICE BOLD O MTRL REFLECTIVE, PERMANENT, TEXT SHALL1 TEXT ® MTRL REFLECTIVE, VEE PERMANENT, TEXT SHALL BE THE 14PT. NON BOLD CBUIILLDING SHALL BE INSTALLED IN METAALRLIC RACEWAY AND DEVICE WHEREEXPOSED DURING SERVICE DED CIRCDUIITS MAY BE O SCALE NTS O MTRL: REFLECTIVE, PERMANENT, TEXT SHALL BE BE WHITE. BACKGROUND SHALL BE RED. TEXT SIZE: 14 PT. NON BOLD WHITE, BACKGROUND SHALL BE RED. AND SHALL BE IDENTIFIED EVERY 1 OFT - AND WITHIN i FT OF 1 WHITE, BACKGROUND SHALL BE RED. WARNING: THIS SERVICE IS SUPPLIED WARNING: INVERTER TURNS AND BENDS. AND WITHIN IN 1FT ABOVE AND OW N BOXESRNING, OR MTBE WHITE, BAINARNING GROUND ALL BRL REFLECTIVE, PERMANENT. E RED. LL ELECTRICA,SHOCK HAZARD O PENETRATIONS ERS AND ALLDROOF/CEILING C C (LING AND JUNCTIO DRAWN BY AA OUTPUT CONNECTION DO NOT TOUCH TERMINALS. MTRL: IN 318" WHITE LETTERING ON RED BACKGROUND - WITH FADE FROM MULTIPLE SOURCES: UTILITYDO NOT RELOCATE THIS TERMINALS ON BOTH THE RESISTANT MATERIAL ELECTRIC SHOCK HAZARD. THE DC AND PHOTOVOLTAIC OVERCURRENT PROTECTION DEVICE CONDUCTORS OF THIS PHOTOVOLTAIC LINE AND LOAD SIDES MAY BE WARNING: PHOTOVOLTAIC POWER SOURCE SYSTEM ARE UNGROUNDED AND MAY ENERGIZED THE OPEN PV=3 BE ENERGIZED POSITION. GENERAL ELECTRICAL REQUIREMENTS. I PV EQUIPMENT LABELS AND NOTES: I GENERAL FIRE GUIDELINES & MARKING REQTS: 1. ALL EQUIPMENT SHALL BE UL -LISTED FOR THE APPLICATION. 2. ALL WORK SHALL COMPLY WITH 2013 CALIFORNIA BUILDING CODE, 2013 CALIFORNIA ELECTRIC CODE, ARTICLE 690, AND ALL MANUFACTURERS LISTINGS AND INSTALLATION INSTRUCTIONS. INSTALLER IS ENCOURAGED TO FOLLOW NEC -2011 WITH A FOCUS ON ARTICLE 690. 3. NO PIPING, DUCTS OR EQUIPMENT FOREIGN TO ELECTRICAL EQUIPMENT SHALL BE PERMITTED TO BE LOCATED WITHIN THE DEDICATED SPACE ABOVE THE ELECTRICAL EQUIPMENT, 4. ALL INSTALLED EQUIPMENT TO CONFORM TO NEC 690.61, AN INVERTER OR AN AC MODULE IN AN INTERACTIVE SOLAR PHOTOVOLTAIC SYSTEM SHALL AUTOMATICALLY DE -ENERGIZE ITS OUTPUT TO THE CONNECTED ELECTRICAL PRODUCTION AND DISTRIBUTION NETWORK UPON LOSS OF VOLTAGE IN THAT SYSTEM AND SHALL REMAIN IN THAT STATE UNTIL THE ELECTRICAL PRODUCTION AND DISTRIBUTION NETWORK VOLTAGE HAS BEEN RESTORED, 5. SYSTEM VOLTAGE CALCULATIONS ARE BASED ON EXPECTED AMBIENT TEMPERATURE OF #"C TO ##'C. 6. ALL INSTALLED EQUIPMENT SHALL BE RATED FOR USE WITH CONDUCTORS RATED FOR 9VC. 7. ALL CONDUCTORS SHALL BE COPPER AND SUITABLE FOR WET LOCATIONS. 8. WIRE TYPE TO BE THWN-2 90DEG C OR EQUAL, EXCEPT THOSE IN FREE AIR, IN FREE AIR USE USE -2. 9. ALL MC CONNECTORS BETWEEN MODULES SHALL BE MC4 TYPE OR EQUIVALENT AND CONNECT INSULATED WIRES RATED FOR 90'C AND WET AND EXPOSED CONDITIONS. 10. CLEAR WORKING SPACE ABOUT EQUIPMENT TO BE PROVIDED AS REQUIRED BY CEC 11026. NO APPARATUS OR OTHER EQUIPMENT FOREIGN TO THE ELECTRICAL INSTALLATION SHALL BE LOCATED IN THE DEDICATED EQUIPMENT SPACE 11. UNDERGROUND CONDUIT RUNS SHALL BE BURIED TO AN 18' MINIMUM DEPTH, EXCEPT WHERE UNDER PARKING LOTS & DRIVEWAYS. A 24' MINIMUM DEPTH UNDER PARKING LOTS & DRIVEWAYS IS REQUIRED. ALL BELOW GRADE RUNS SHALL HAVE THEIR LOCATION IDENTIFIED BY A WARNING RIBBON THAT IS PLACED IN THE TRENCH AT LEAST 12' ABOVE THE UNDERGROUND INSTALLATION 12. ALL INSTALLATION IS ABOVE GROUND. 13. ALL FITTINGS AND HUBS SHALL BE RATED FOR RAIN OR WET LOCATION AND COMPLY WITH UL 514B. 14. WHERE CONDUIT ENTERS BOX, FITTING OR OTHER ENCLOSURE, A GROUNDING WIRE IS USED. BONDING JUMPERS TO BE INSTALLED AROUND CONCENTRIC OR ELECTRIC KNOCKOUTS. 15. GROUNDING METHOD SHALL BE CONTINUOUS AND SUCH THAT REMOVAL OF ANY PIECE OF EQUIPMENT SHALL NOT INTERRUPT THE GROUNDING OF ANY OTHER PIECE OF EQUIPMENT. 16. WHERE EVER FIRE RATED BUILDING ASSEMBLIES ARE PENETRATED, SEAL PENETRATION WITH FIRE -RATED SEALANT SO AS TO MAINTAIN REQUIRED RATING PER CBC, CHAPTER 7. 17. INVERTERS TO BE INSTALLED HAVE BEEN TESTED AND LISTED BY UNDERWRITERS LABORATORIES TO MEET THE REQUIREMENTS OF UL1741 STATIC INVERTERS AND CHARGE CONTROLLERS FOR USE IN PJ POWER SYSTEMS AND UL1998 SOFTWARE PROGRAMMABLE COMPONENTS, AS WELL AS IEEE4129-2000. 18. DC CONDUCTOR SIZING BASED ON ISC MINIMUM AMPACITY PER NEC 690.9. TEMPERATURE DERATING BASED ON TABLE 310.16, CALC'D AT 90 DEGREES C. CONDUCTOR DERATING BASED ON NEC 310.15(B)(2)(A) AND ON NUMBER OF CURRENT CARRYING CONDUCTORS IN CONDUIT. CONDUIT S12E PER NEC ANNEX C, TABLE Cl. 19. DC DISCONNECT LOCATION SHALL BE IN COMPLIANCE WITH NEC690.14(C)(1). READILY ACCESSIBLE, OUTSIDE OF STRUCTURE OR IF INSIDE, NEAREST TO SYSTEM CONDUCTOR ENTRANCE POINT. 20. DC EQUIPMENT GROUND -CONTINUOUS DC GEC -BOND DIRECTLY TO MAIN AC GEC 21. INDIVIDUALLY GROUND ALL MODULE FRAMES, RAILS AND MOUNTING STRUCTURE USING BARE COPPER WIRE EMPLOYING SEPARABLE CONNECTION IN ACCORDANCE WITH NECK 250.124(A). USE APPROVED LAY-UP LUGS ATTACHED WITH STAINLESS STEAL: 18-8 GRADE OR HIGHER, 24 OR 32 THREADS PER INCH. 22. EQUIPMENT GROUNDING CONDUCTORS SMALLER THAN 6 AWG SHALL BE PROTECTED FROM PHYSICAL DAMAGE BY RACEWAY OR CABLE ARMOR EXCEPT WHERE NOT SUBJECT TO OR WHERE PROTECTED FROM PHYSICAL DAMAGE. 23. AC, DC DISCONNECT AND ALL OTHER APPLICABLE EQUIPMENT TO BE LABELED PER 69054 AD A POWER SOURCE WITH OPERATING CURRENT & SHORT CIRCUIT CURRENT. 24. CONTRACTOR TO FIELD VERIFY ALL DIMENSIONS AND CONDITIONS PRIOR TO CONSTRUCTION 25. SPLICING CONNECTORS: POLARIS CONNECTORS 26. DC ARRAY CONDUCTORS ARE TO REMAIN OUTSIDE OF BUILDING PRIOR TO FUSEABLE COMBINER BOX OR FUSEABLE DC DISCONNECTING MEANS. FUSEABLE DISCONNECTING MEANS IS REQUIRED OUTSIDE OF THE BUILDING, §690.14(C)(1) 27. INSPECTION REQUIRED FOR ROOF CONNECTION MOUNTING ASSEMBLIES PRIOR TO INSTALLATION OF SOLAR MODULE. 28. THE RESPONSIBILITY OF RE -CERTIFYING WINDOWS PER NFRC IS REQUIRED AND PROVIDED BY THE ARCHITECT. 29. EQUIPMENT OVER 600 VOLTS SHALL COMPLY WITH ARTICLE 490 30. FOR CIRCUITS OVER 250 VOLTS TO GROUND, THE ELECTRICAL CONTINUITY OF METAL RACEWAYS SHALL BE ENSURED BY CONNECTIONS USING THREADED COUPLINGS OR LISTED DEVICES SUCH AS BONDING TYPE LOCKNUTS OR BUSHINGS WITH BONDING JUMPERS. 31. RACEWAYS FOR GEC SHALL BE BONDED AT EACH END. 32. FOR DC EQUIPMENT INSTALLED ON THE ROOF, CONDUIT, WIRING SYSTEMS, AND RACEWAYS SHALL BE LOCATED AS CLOSE AS POSSIBLE TO THE RIDGE, HIP, OR VALLEY AND SHALL RUN FROM THE RIDGE, HIP, OR VALLEY DIRECTLY TO AN OUTSIDE WALL DC COMBINER BOXES SHALL BE LOCATED SO AS TO MINIMIZE CONDUIT RUNS IN PATHWAYS BETWEEN ARRAYS. DC WIRING LOCATED INSIDE BUILDING SHALL BE RUN IN METALLIC CONDUIT OR IN RACEWAYS AND SHALL BE RUN ALONG THE BOTTOM OF LOAD BEARING STRUCTURAL FRAMING MEMBERS WHEREVER FEASIBLE. 33. DIRECT-CURRENT PHOTOVOLTAIC SOURCE AND OUTPUT CIRCUIT OF A UTILITY INTERACTIVE INVERTER FROM A BUILDING INTEGRATED OR OTHER PHOTOVOLTAIC SYSTEM SHALL BE RUN OUTSIDE A BUILDING UNLESS CONTAINED IN METALLIC RACEWAYS OR ENCLOSURES FROM THE POINT OF PENETRATION OF THE SURFACE OF THE BUILDING OR STRUCTURE TO THE FIRST READILY ACCESSIBLE DISCONNECTING MEANS. 34. WHEN THE COMBINED RATING OF THE MAIN BREAKER SERVING A PANEL AND THE SOLAR BREAKER EXCEEDS THE BUSS BAR RATING, THE SOLAR BREAKER MUST BE AT THE END OPOSITE THE MAIN BREAKER. 1. LABEL "CAUTION: SOLAR CIRCUIT" SHALL BE ON ALL EXPOSED CONDUIT, ENCLOSURES, CABLE ASSEMBLIES, JUNCTION BOXES. 2. LABELS SHALL HAVE WHITE LETTERING WITH RED BACKGROUND. 3. LABELS LETTERING SHALL BE ALL CAPITAL LETTERS, ARIAL OR EQUAL FONT, AND A MINIMUM OF 3/8" HEIGHT AND SIZE. 4. LABELS MINIMUM SIZE (HEIGHT =4", WIDTH =4") S. LABELS SHALL BE REFLECTIVE, WEATHER RESISTANT MATERIAL. 6. ALL PV SYSTEM COMPONENTS SHALL BE USTED BY A RECOGNIZED TESTING AGENCY. 7. WIRING MATERIAL SHALL BE SUITABLE FOR SUN EXPOSURE AND WET LOCATIONS. FILED APPLIED PROTECTIVE COATINGS ARE NOT ACCEPTABLE. B. SIGNS SHALL BE POSTED ADJACENT TO EACH PV DISCONNECT AND INVERTER TO INDICATE "PHOTOVOLTAIC SYSTEM" 9. ALL PV MODULES AND ASSOCIATED EQUIPMENT AND WIRING MATERIAL SHALL BE PROTECTED FROM ANY PHYSICAL DAMAGE. 10. ALL FIELD INSTALLED JUNCTION, PULL AND OUTLET BOXES LOCATED BEHIND MODULES OR PANELS SHALL BE ACCESSIBLE DIRECTLY OR BY DISPLACEMENT OF A MODULE(S) OR PANELS(S) SECURED BY REMOVABLE FASTENERS. 11. THE ROOF MOUNTED PHOTOVOLTAIC MODULES, PANELS, OR SOLAR VOLTAIC ROLL ROOFING MATERIAL SHALL HAVE THE SAME OR BETTER USTED FIRE -RESISTANCE RATING THAN THE BUILDING ROOF -COVERING MATERIAL. 12. PHOTOVOLTAIC DC CONDUCTORS ENTERING THE BUILDING SHALL BE INSTALLED IN A METALLIC RACEWAY AND SHALL BE IDENTIFIED EVERY I OFT - AND WITHIN 1 FT OF TURNS AND BENDS, AND WITHTIN 1 FT ABOVE AND BELOW PENETRATIONS OF ROOF/CEILING ASSEMBLIES, WALLS, OR BARRIERS - WITH MINIMUM 3/8" HIGH WHITE LETTERING ON RED BACKGROUND READING: "WARNING: PHOTOVOLTAIC POWER SOURCE" §690.5(C) LABELS AND MARKINGS: A WARNING LABEL SHALL APPEAR ON THE UTIUTY-INTERACTIVE INVERTER OR BE APPLIED BY INSTALLER NEAR THE GROUNG-FAULT INDICATER AT A VISSIBLE LOCATION, SATTING THE FOLLOWING: WARNING ELECTRICAL SHOCK HAZARD IF A GROUND FAULT IS INDICATED, NORMALLY GROUNDED CONDUCTORS MAY BE UNGROUNDED AND ENERGIZED APPLIED BY THE INSTALLER IN A VISIBLE LOCATION AT THE BATTERIES. 5690.14(C)(2) MARKING: EACH PHOTOVOLTAIC SYSTEM DISCONNECTING MEANS SHALL BE PERMANENTLY MARKED TO IDENTIFY IT AS A PHOTOVOLTAIC SYSTEM DISCONNECT. §690.15 DISCONNECTION OF PHOTOVOLTAIC EQUIPMENT MEANS SHALL BE PROVIDED TO DISCONNECT EQIPMENT, SUCH AS INVERTERS, BATTERIES, CHARGE CONTROLLERS, AND THE LIKE, FROM ALL UNGROUNDED CONDUCTORS OF ALL SOURCES. IF THE EQUIPMENT IS ENERGIZED FROM MORE THAN ONE SOURCE, THE DISCONNECTING MEANS SHALL BE GROUPED AND IDENTIFIED. §690.17 SWITCH OR CIRCUIT BREAKER: THE DISCONNECTING MEANS FOR UNGROUNDED CONDUCTORS SHALL CONSIST OF A MANUALLY OPERABLE SWITCHES) OR CIRCUIT BREAKER(S) COMPLYING WITH ALL THE FOLLOWING REQUIREMENTS: 1. LOCATED WHERE READILY ACCESSIBLE 2. EXTERNALLY OPERABLE WITHOUT EXPOSING THE OPERATOR TO CONTACT WITH LIVE PARTS 3. PLAINLY INDICATING WHETHER IN THE OPEN OR CLOSED POSITION 4. HAVING AN INTERRUPTING RATING SUFFICIENT FOR THE NOMINAL CIRCUIT VOLTAGE AND THE CURRENT THAT IS AVAILABLE AT THE LINE TERMINALS OF THE EQUIPMENT 5. WHERE ALL TERMINALS OF THE DICONNECTING MEANS MAY BE ENERGIZED IN THE OPEN POSITION, A WARNING SIGN SHALL BE MOUNTED ON OR ADJACENT TO THE DISCONNECTING MEANS. THE SIGN SHALL BE CLEARLY LEGIBLE AND HAVE THE FOLLOWING WORDS: WARNING ELECTRICAL SHOCK HAZARD DO NOT TOUCH TERMINALS. TERMINALS ON BOTH THE UNE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION. §690.53 DIRECT-CURRENT PHOTOVOLTAIC POWER SOURCE: APERMANENT LABEL FOR THE DIRECT-CURRENT PHOTOVOLTAIC POWER SOURCE INDICATING ITEMS (1) THROUGH (5) SHALL BE PROVIDED BY THE INSTALLER AT THE PHOTOVOLTAIC DISCONNECTING MEANS: 1. RATED MAXIMUM POWER -POINT CURRENT 2. RATED MAXIMUM POWER -POINT VOLTAGE 3. MAXIMUM SYSTEM VOLTAGE FPN TO (3): SEE 690.7(A) FOR MAXIMUM PHOTOVOLTAIC SYSTEM VOLTAGE. 4. SHORT-CIRCUIT CURRENT FPN TO (4): SEE 690.8(A) FOR CALCULATION OF MAXIMUM GRCUIT CURRENT. 5. MAXIMUM RATED OUTPUT CURRENT OF THE CHARGE CONTROLLER (IF INSTALLED) FPN: REFLECTING SYSTEMS USED FOR IRRADIANCE ENHANCEMENT MAY RESULT IN INCREASED LEVELS OF OUTPUT CURRENT AND POWER. §0.54 INTERACTIVE SYSTEM PONT OF INTERCONNECTION. ALL INTERACTIVE SYSTEM(S) POINTS OF INTERCONNECTION WITH OTHER SOURCES SHALL BE MARKED AT AN ACCESSIBLE LOCATION AT THE DISCONNECTING MEANS AS A POWER SOURCE AND WITH THE RATED MAX AC OUTPUT CURRENT AND THE NOMINAL OPERATING AC VOLTAGE. §690.56(6) FACILITIES WITH THE UTILITY SERVICES AND PV SYSTEMS. BUILDING OR STRUCTURES WITH BOTH UTILITY SERVICE AND PHOTOVOLTAIC SYSTEM SHALL HAVE A PERMANENT PLAQUE OR DIRECTORY PROVIDING THE LOCATION OF THE SERVICE DISCONNECTING MEANS AND THE PHOTOVOLTAIC SYSTEM DISCONNECTING MEANS IF NOT LOCATED AT THE SAME LOCATION. §690.64(6)4) MARKING. EQUIPMENT CONTAINING OVERCURRNET DEVICES IN CIRCUITS SUPPLYING POWER TO A BUSBAR OR CONDUCTOR SUPPLED FROM MULTIPLE SOURCES SHALL BE MARKED TO INDICATE THE PRESENCE OF ALL SOURCES. SEC. 5, MARKINGS, LABELS, AND WARNING SIGNS. A. PURPOSE: PROVIDES EMERGENCY RESPONDERS WITH APPROPRIATE WARNING AND GUIDANCE WITH RESPECT TO ISOLATING THE SOLAR ELECTRICAL SYSTEM. THIS CAN FACILITATE IDENTIFYING ENERGIZED ELECTRICAL LINES THAT CONNECT THE SOLAR PANELS TO THE INVERTER, AS THESE SHOULD NOT BE CUT WHEN VENTING FOR SMOKE REMOVAL. B. MAIN SERVICE DISCONNECT: 1. RESIDENTIAL BUILDINGS: THE MARKING MAY BE PLACED WITHIN THE MAIN SERVICE DISCONNECT. THE MARKING SHALL BE PLACED ON THE OUTSIDE COVER IF THE MAIN SERVICE DISCONNECT IS OPERABLE WITH THE SERVICE PANEL CLOSED. 2. COMMERCIAL BUILDINGS: THE MARKING SHALL BE PLACED ADJACENT TO THE MAIN SERVICE DISCONNECT CLEARLY VIGIDLC TROM TI IC LOCATION WI ICRC TI2 LEVER IS OPERATED. 3. MARKINGS: VERBIAGE, FORMAT, AND TYPE OF MATERIAL A. VERBIAGE: CAUTION: SOLAR ELECTRIC SYSTEM CONNECTED B. FORMAT: (1) WHITE LETTERING ON A RED BACKGROUND. (2) MINIMUM 318 INCHES LETTER HEIGHT. (3) ALL LETTERS SHALL BE CAPITALIZED. (4) ARWL OR SIMILAR FONT, NON -BOLD. C. MATERIAL: (1) REFLECTIVE, WEATHER RESISTANT MATERIAL SUITABLE FOR THE ENVIRONMENT (USE UL -969 AS STANDARD FOR WEATHER RATING). DURABLE ADHESIVE MATERIALS MEET THIS REQUIREMENT, C. MARKING REQUIREMENTS ON DC CONDUIT, RACEWAYS, ENCLOSURES, CABLE ASSEMBLIES, DC COMBINERS, AND JUNCTION BOXES: 1. MARKINGS: PLACEMENT, VERBIAGE, FORMAT, AND TYPE OF MATERIAL. A. PLACEMENT: MARKINGS SHALL BE PLACED EVERY 10 FEET ON ALL INTERIOR AND EXTERIOR DC CONDUITS, RACEWAYS, ENCLOSURES, AND CABLE ASSEMBLIES, AT TURNS, ABOVE AND FOR BELOW PENETRATIONS, ALL DC COMBINERS, AND JUNCTION BOXES. B. VERBIAGE; CAUTION: SOLAR CIRCUIT NOTE: THE FORMAT AND TYPE OF MATERIAL SHALL ADHERE TO V.13,38, C OF THIS REQUIREMENT. C. INVERTERS ARE NOT REQUIRED TO HAVE CAUTION MARKINGS. SEC. 7. DIRECT CURRENT (DC) CONDUCTOR LOCATIONS. A. CONDUIT, WIRING SYSTEMS, AND RACEWAYS: I. LOCATED AS CLOSE AS POSSIBLE TO THE RIDGE, HIP OR VALLEY AND FROM THE HIP OR VALLEY AS DIRECTLY AS POSSIBLE TO AN OUTSIDE WALL B. CONDUIT RUNS BETWEEN SUB ARRAYS AND DC COMBINER BOXES SHALL: 1. USE DESIGN GUIDELINES THAT MINIMIZES THE TOTAL AMOUNT OF CONDUIT USED ON THE ROOF BY TAKING THE SHORTEST PATH FROM THE ARRAY TO THE DC COMBINER BOX. 2. THE DC COMBINER BOXES ARE TO BE LOCATED SUCH THAT CONDUIT RUNS ARE MINIMIZED M THE PATHWAYS BETWEEN ARRAYS. C. DCWIRING: 1. DC WIRING SHALL BE RUN IN METALLIC CONDUIT OR RACEWAYS WHEN LOCATED WITHIN ENCLOSED SPACES IN A BUILDING. 2. WHEN POSSIBLE DC WIRING SHALL RUN ALONG THE BOTTOM OF LOAD-BEARING MEMBERS. SFC. R. GROUND MOUNTED PHOTOVOLTAIC ARRAYS. A. SETBACK REQUIREMENTS: 1. DOES NOT APPLY TO GROUND MOUNTED FREESTANDING PHOTOVOLTAIC ARRAYS. 2. A 10 FEET MINIMUM CLEARANCE IS REQUIRED AROUND GROUND -MOUNTED PHOTOVOLTAIC SYSTEMS. 3. SHALL NOT OBSTRUCT FIRE DEPARTMENT ACCESS, SEC. 9. OVERHEAD ARRAYS ON ROOFTOPS (E.G. TRELLIS SYSTEMS). A. MINIMUM REQUIREMENTS: 1. OVERHEAD ARRAYS SHALL COMPLY WITH THE SAME MARKING, LABELING, AND WARNING SIGNS AS REQUIRED OF ROOF -MOUNTED SYSTEMS. 2. THERE SHALL BE AN UNOBSTRUCTED CLEARANCE OF SEVEN FEET OR MORE BETWEEN THE ROOF DECK SURFACE AND THE UNDERSIDE OF THE OVERHEAD ARRAY. 3. THE REGULATIONS IN 57.12.03, AND 57.138.04 OF THE LOS ANGELES FIRE CODE SHALL BE COMPLIED WITH. 4. AN UNINTERRUPTED SECTION OF SOLAR PHOTOVOLTAIC PANELS SHALL NOT EXCEED 150 FEET BY 150 iEET IN DIMENSION IN EITHER AXIS. 5. THE OVERHEAD CLEAR WIDTH BETWEEN ARRAYS OR SUB -ARRAYS SHALL BE FOUR FEET OR GREATER EXTENDING FROM THE EDGE OF THE ARRAY(S) TO THE ROOF DECK SURFACE, THEREBY, MAINTAINING AN UNOBSTRUCTED ACCESS PATHWAY, AND PROVIDING FOR EMERGENCY VENTILATION PROCEDURES. THE USE OF THE AREA BELOW ARRAYS IS PROHIBITED. 20750 VENTURA BLVD. SUITE 430 WOODLAND HILLS, CA, 91364 P. 818.924.2485 SOL FUSION. LiCENSE NO. 980873 CL: B, C i0 10/31/14 SIGNATURE DATE GENERAL NOTES & SIGNAGE REV DESCRIPTION DATE DATE 11/6/2014 SCALE NTS DRAWN BY AA PV -4 LO Ln C N 0 W Q C/) U U Q I� Z H A♦ Z _0 co, W W c cn >, U) cri W a Y c Z Ir J J Z I LO (� Z z (1) CO Ww W O > � w Q Z Q 0 mr c U I- w p - O i Z 00 Q 0 w W w 3 w N w- -) .- TA O z W0 r '� OIr >, z GENERAL NOTES & SIGNAGE REV DESCRIPTION DATE DATE 11/6/2014 SCALE NTS DRAWN BY AA PV -4 WW SunEdisori SILVANTIS ADVANTAGE • 16.89% module efficiency with positive power tolerance • PID -free: compatible with transformerless and multi-MPPT inverters • Higher return on investment with more watts -per -module • Reliability tested beyond international standards • Utility -grade manufacturing: ISO 14001, ISO 9001 and 100% EL inspection QUALITY 8 SAFETY ROBUST 13 AESTHETIC DESIGN • Industry leading PID test conditions: • Black anodized corrosion resistant aluminum frame 96 hours, 85 C, 85% relative humidity, 1kV » White back sheet: SE-F2xxCzC-3y • IEC certified by TUV SOD: Black back sheet: SE-F2xxKzC-3y n 61730 to ensure electrical safety • Low glare anti -reflective coated (ARC) tempered 61215 long term operation in a variety of glass climates including snow loading up to 5400 Pa and hail testing SUNEDISON WARRANTY 61701 Level 1 salt mist corrosion resistant for 25 -year limited warranty for materials and marine regions workmanship for residential applications 62716 ammonia testing for agricultural 25 -year linear power warranty at STC: environments a Year 1 5 3.5% of rated power • CSA listed to UL 1703 for 1,000 V systems in the » After year 1 : S 0.7% rated power degradation US and Canada per year • MCS certified for UK • TS16949 6 AQL Level II -0.4 manufacturing quality m� SunEdieon'e Linear Warranty �A` 1! PY CYCLE e c us 'tiaN e �. C E © $� u VAC I Z 3 • 3 B B 9 1B 11 12 13 la 15 It 11 18 IB 20 21 W 23 2• n YM aaa•rwt7ca 1 WSunEdison SILVANTIS F -SERIES: 255 W TO 275 W PHYSICAL PARAMETERS Module Dimensions 1,658 mm x 990 mm x 50 mm Module Weight 19.3 kg Cell -Type Continuous CZ (CCz) monocrystalline Number of Cells 60 Frame Material Black Anodized ALrminum U Tempered ARC Glass Thickness W 32 mm Q TEMPERATURE COEFFICIENTS AND PARAMETERS' U Nominal Operating Cell Temperature (NOCT) UQ 46C ± 2C Temperature Coefficient of Pmax -0.45 %/C Temperature Coefficient of Voc Z -0.34 %/C - Temperature Coefficient of Isc +0,06 %/C Operating Temperature -40 C to +85 C W Maximum System Voltage 1000 V (UL E IEC) Limiting Reverse Current 9.20 A Maximum Series Fuse Rating 15A Power Selection Q -0 W to +5 W Junction Box Rating IP67 -(D IEC 61730 Application Class A Packaging Specifications 0 � W V C Z a) IM Z Q LO J 0 Z Z N C? W , W O > 0) Q uiCc Z w av Q � � � Ci W 0 Z V W m a o w W w w N w OW Z O r O A 0- Z o 2 0- °O a- C3' Cn MODULE SPECS REV DESCRIPTION DATEI IIII I IIIIIIIIIIII I V III I,II IIIIIIIIIIIIIIIIIIII (IIII IIII II IIIIIIIIIIIII,IIII VIII (IIII II11111111111111111111 111111 IIII11111111111IIII II II II II IIIIIIII DATE 11/3/2014 III II II I1111111111111IIIIIIIIIIIIII SCALE NTS I 1111111111IIII III I DRAWN BY AA I I IIIIIIIII11Illlt V III I PV -5 Enphase Microinverters EnphasaIM250 I The Enphase" M250 Microinverter delivers increased energy harvest and reduces design and installation complexity with its all -AC approach. With the M250, the DC circuit is isolated and insulated from ground, so no Ground Electrode Conductor (GEC) is required for the microinverter. This further simplifies installation, enhances safety, and saves on labor and materials costs. The Enphase M250 integrates seamlessly with the Engage Cable, the Envoy" Communications GatewayT", and Enlighten Enphase's monitoring and analysis software. PRODUCTIVE Optimized for higher -power modules Maximizes energy production Minimizes impact of shading, dust, and debris ea enphase° Enphase' M250 Microinverter ii DATA INPUT DATA (DC) Recommended input power (STC) Maximum input DC voltage Peak power tracking voltage Operating range Min/Max start voltage M250-60-2LL-S22/S23/S24 210 - 300 W 48 V 27V -39V 16V -48V 22V/48V Max DC short circuit current 15 A Max input current 10A OUTPUT DATA (AC) @208 VAC @240 VAC Peak output power 250 W 250 W Rated (continuous) output power 240 W 240 W Nominal output current 1.15 A (A rms at nominal duration) 1.0 A (A rms at nominal duration) Nominal voltage/range 208 V / 183-229 V 240 V / 211-264 V Nominal frequency/range 60.0 / 57-61 Hz 60.0 / 57-61 Hz Extended frequency range" 57-62.5 Hz 57-62.5 Hz Power factor >0.95 >0.95 Maximum units per 20 A branch circuit 24 (three phase) 16 (single phase) Maximum output fault current 850 mA rms for 6 cycles 850 mA rms for 6 cycles EFFICIENCY ..... ...... .... CEC weighted efficiency, 240 VAG 96.5% CEC weighted efficiency, 208 VAC 96.0% Peak inverter efficiency 96.5% Static MPPT efficiency (weighted, reference EN50530) 99.4% Night time power consumption 65 mW max MECHANICAL DATA Ambient temperature range -40°C to +65°C Operating temperature range (internal) -40°C to +85°C Dimensions (WxHxD) 171 mm x 173 mm x 30 mm (without mounting bracket) Weight 2.0 kg Cooling Natural convection - No fans Enclosure environmental rating Outdoor - NEMA 6 FEATURES 20750 VENTURA BLVD. SUITE 430 WOODLAND HILLS, CA, 91364 P. 818.924.2485 Snl FUSION. LICENSE NO. 980873 CL: B, C10 10/31/14 SIGNATURE DATE W U Z W Q U) W Ir J INK. 0 2 z o w W O Ir Z J 0 W Z W 00 W W ZW O 2 co N N CA U Q Z .o 9 Ir Q U) Y Z_ J Z W w Q W _Q o = w N O Ir a CO 0) U) W 7 ry 00 !_ Z3 U i Q (1) 0) U) C� C/) cy) Z LO Z C? O > O U CO LU Q C) S✓ W O 'L R- (n INVERTER SPECS Compatibility Compatible with 60 -cell PV modules. REV DESCRIPTION DATE SIMPLE RELIABLE Communication Power line No GEC needed for microinverter 4th -generation product Integrated ground The DC circuit meets the requirements for ungrounded PV arrays in No DC design or string calculation More than 1 million hours of testing NEC 690.35. Equipment ground is provided in the Engage Cable. No required and millions of units shipped additional GEC or ground is required. Ground fault protection (GFP) is integrated into the microinverter. Easy installation with Engage Industry-leading warranty, up to 25 Monitoring Free lifetime monitoring via Enlighten software Cable years Compliance UL1741/IEEE1547, FCC Part 15 Class B, CAN/CSA-C22.2 NO. 0-M91, DATE 11/3/2014 0.4-04, and 107.1-01 SCALE NTS Frequency ranges can be extended beyond nominal if required by the utility DRAWN BY AA S, To learn more about Enphase Microinverter technology,enphase` visit enphase.com ��� G N E F G v 0 2013 Enpliase Energy. All rights reserved- All trademarks or brands in this document are registered by their respective owner PV -6 Engage Cable System and Accessories Enphase Engage Cable The EngageTM Cable is a continuous length of 12AWG cable with pre-installed connectors for Enphase Microinverters. The cable is handled like standard outdoor -rated electrical wire, allowing it to be cut, spliced and extended as needed. The Engage Accessories complement the Engage Cable and give it the ability to adapt to any installation. FAST Quick installation Large branch capacity [e] enphase E N E R G Y FLEXIBLE SAFE Simple design No high voltage DC No additional cables Reduced fire risk Ic lis 20750 VENTURA BLVD. SUITE 430 WOODLAND HILLS, CA, 91364 P. 818.924.2485 SOL FUSION. LICENSE NO. 580873 CL: B, C10 s.. 10/31/14 SIGNATURE DATE Enphase"' Engage Cable System // DATA N N CABLE TYPES / ORDERING OPTIONS LU Q CI Voltage Connector Spacing PV Module Orientation Model Number #Connectors* Weight— U 240 VAC, 4 conductors 1.025 meter (40") Portrait ET10-240-40 40 40 lbsU - > CL Y 240 VAC, 4 conductors 1.7 meter (67") Landscape ET17-240-40 40 45 lbsz H T -0 'l 208 VAC, 5 conductors 1.025 meter (40") Portrait ET10-208-30 30 30 lbs Z 1 208 VAC, 5 conductors 1.7 meter (67") Landscape ET17-208-30 30 35 lbs W ( U E +• Description Rating� U) Cf)Cable temperature rating 90°C (194°F) wet/dry _ (1 Cable insulator rating THWII W Y UV exposure rating UL 746 C, F1 Z Cc J z Conductor size 12AWG Q J LO U Compliance IEC 60529 IP67, CAN/CSA 22.2 No. 21, 182.3, UL 486A/B, 514C, 6703, and 9703 J Z Z (D C'7W to W U > Cable rating TC -ER - Q 7 w 0 ° U 0 Q U Cable Diameter 1.25 cm (0.49") I— p U Minimum bend radius 12 cm (4.75") Z LU UQ 0 w W w CO w N w cr ENGAGE ACCESSORIESO Z LUO T O j Cc Z O= a 00 aid () Branch Terminator Disconnect Tool One terminator needed per branch Plan to use at least one per circuit installation ET -TERM -10 (sold in packs of 10) ET -DISC -05 (sold in packs of 5) INVERTER SPECS Watertight Sealing Cap: Cable Clip ® One needed to cover each unused _ i Many needed to fasten cabling connector on the cabling ��' to the racking or to secure looped E ET -CLIP -100 (sold in packs of 100) ET -SEAL -10 (sold in packs of 10) I cabling REV DESCRIPTIONI. DAT Engage Coupler Used for splicing two power cables within an array ET-SPLK-05 (sold in packs of 5) DATE 11/3/2014 SCALE NTS DRAWN BY AA To learn more about Enphase Microinverter technology, r enphase, visit enphase.com E N E R G Y 0 2013 Enphase Energy. All rights reserved. All trademarks or brands in this document are registered by their respective owner. PV -7 Third Party R Lab Tested T)11eT1r(3C 1,740 lbs' oo'Patent #5,746,029 V pullout alue j Tile Roof Structural Attachment The patented TileTracou attachment allows for a structural roof rafter connection with optimal attachment stud location odjustability. Design results in the best looking systems in the industry. Tile Trac "for s -curve concrete tile lI Tall Threaded Stud) Part # TT -18-T6 Tile Trac ca forfat concrete the (4" Tall Threaded Stud) Benefits of the TileTrac Part # TT -18d4 • Industry's most cost effective the • Aluminum and Stainless Steel components for attachment product corrosion resistance and strength • Minimal install labor and time • 1,740 lbs of 3rd party lab tested pullout strength • Over 12 years of industry • Water -tight seal lab tested for 7 days under 34 preferred design inches of water, zero leakage • Requires only one Stainless Steel • 10 sq. inches of base area evenly distributes roof lag bolt (included) load and provides sufficient sealant bonding area professional The TileTrac-, Design Structurally attaches to roof rafter and allows the rail attachment stud to be SOLAR located at the strongest point of the tile (the crown) where water does not now. products Inc. Without TileTrac° With TileTrac" Rafter Not structurally attached to the rafter Water Flows High Point/ Support Rail in the Valle Crown y of the Tile of the Tile r (optimum) TileTrac assembly structurally attached Rafter to the rafter Installation steps for both s -curve and flat concrete tile* STEP 1: Select a file in the area of the roof rafter. Step 4: Seal the initial tile nail hole. Using a 3/16" drill bit and drill guide (FJ -Drill), drill pilot hole along the rafter renter STEP 2: Remove the file by pushing and pulling. It is usually held in place by a small nail. Step 5: Insert the lag bolt and washer through the TileTrac' and apply fresh room temperature sealant to the base. Step 7: After bolting the base to the roof, slide the upper carriage into the correct position under the crown of the tile. For Flat tile, slide the upper mrrioge near the middle of the tile. Step 8: Replace the tile by lining up the snap lines and nark the drill locution accordingly. STEP 3: Using an electronic stud finder (recommended), or other means, locate the rafter center. Mark a reference point on the file above. Step 6: Using a 1/2" socket, install the lag bolt until seated. Do not overtighten. The sealant should flow outward sealing any holes. Step 9: Using a 3/8" carbide drill bit and ROTARY HAMMER DRILL in hammer mode, drill through the tile. See online video at www.prosolar.corn for details. Step 10: Insert the threaded stud through the file and Step 11: Unbind nuts and remove from stud. Apply UV ruled tighten with 9/16" wrenches to engage stud with base. Bind sealant between stud base and tile and compress with a two 3/8" nuts (included) using 9/16" wrenches and tighten. 3/8" washer. Apply UV rated sealant around top of washer. `Not recommended for clay or slate tiles. Step 12: Fasten rail with lower and upper 3/8" nuts/washers as shown. ©Professional Solar Products, Inc. June 2008. TileTrac"is a registered trademark and covered under Pat. #5,746,029 20750 VENTURA BLVD. SUITE 430 WOODLAND HILLS, CA, 91364 P. 818.924.2485 SOL FUSION. LICENSE NO. 980873 CL: B, C10 10/ SIGNATURE DATE 4 RACKING SPECS REV DESCRIPTION DATE I—II . III DATE 11/3/2014 SCALE....., NTS DRAWN BY AA PV -8 co N a) rn 4-1 W Q U U C Q Z H T U) c� W Y 0 Z tY I J Z 1 Q r LC) J C3 Z zryM W vi W O >_ (7) uj Q Z W C)a 0 2 < ZC'3 H W Q0cr — Q= (0 — � U I— o WLU Wm WP, W 0 r a_Z r UJ O2 aco it ISE (3 RACKING SPECS REV DESCRIPTION DATE I—II . III DATE 11/3/2014 SCALE....., NTS DRAWN BY AA PV -8 SOLARMOUNT Beam Connection Hardware SOLARMOUNT L -Foot Part No. 304000C, 304000D Y 1 ►x 3X St 07 FOR 'b.A DWa F 2.0'. Dimensions specified in inches unless noted :FUNIRAC • L -Foot material: One of the following extruded aluminum alloys: 6005- T5, 6105-T5, 6061-T6 • Ultimate tensile: 38ksi, Yield: 35 ksi • Finish: Clear or Dark Anodized • L -Foot weight: 0.215 lbs (98g) • Allowable and design loads are valid when components are assembled with SOLARMOUNT series beams according to authorized UNIRAC documents Foot For the beam to L -Foot connection: • Assemble with one ASTM F593 W-16 hex head screw and one ASTM F594 Wserrated flange nut • Use anti -seize and tighten to 30 ft -lbs of torque • Resistance factors and safety factors are determined according to part 1 section 9 of the 2005 Aluminum Design Manual and third -party test results from an IAS accredited laboratory NOTE: Loads are given for the L -Foot to beam connection only; be sure to check load limits for standoff, lag screw, or other attachment method Applied Load Direction Average Ultimate lbs (N) Allowable Load lbs (N) Safety Factor, FS Design Load Ibs (N) Resistance Factor, m Sliding, Z± 1766 (7856) 755 (3356) 2.34 1141 (5077) 0.646 Tension, Y+ 1859 (8269) 707 (3144) 2.63 1069 (4755) 0.575 Compression, Y- 13258 (14492) 1325 (5893) 2.46 2004 (8913) 0.615 Traverse, X± 486 (2162) 213 (949) 2.28 323 (1436) 0.664 SOLARMOUNT Beams Part No. 310132C, 310132C -B, 310168C, 310168C-8, 310168D 310208C,310208C-B,310240C,310240C-B,310240D, 410144M, 410168M, 410204M, 410240M 20750 VENTURA BLVD. SUITE 430 WOODLAND HILLS, CA, 91364 P. 818.924.2485 8H U N I RAC SOL FUSION. on LICENSE NO. 980873 CL: B, C10 SIGNATURE DATE Properties Units SOLARMOUNT SOLARMOUNT HD Beam Height in 2.5 3.0 Approximate Weight (per linear ft) plf 0.811 1.271 Total Cross Sectional Area in' 0.676 1.059 Section Modulus (X -Axis) in' 0.353 0.898 Section Modulus (Y -Axis) in' 0.113 0.221 Moment of Inertia (X -Axis) in' 0.464 1.450 Moment of Inertia (Y -Axis) in 0.044 0.267 Radius of Gyration (X -Axis) in 0.289 1.170 Radius of Gyration (Y -Axis) in 0.254 0.502 Rails are extruded using these aluminum alloys: 6005-T5, 6105-T5, 6061-T6 SLOT FOR T -BOLT OR 1/a" HEX HEAD SCREW 2X SLOT FOR BOTTOM CLIP 2.500 T 1.316 SLOT FOR 3/8" HEX BOLT 3.7 �I 750 _����!_��J Y A ►X SOLARMOUNT Beam SLOT FOR T -BOLT OR 1.728 I/a" HEX HEAD SCREW SLOT FOR BOTTOM CLIP SUPPORT RAIL SPECS 3.000 toto E DATEI SLOT FOR 1.385 III HEX BOLT 1 1 Jill 'f 1.607 ��l.5 1 1 l 1 I I I 1 1 1 1111 111111111111111111111 A 11111 Y —� "-'Q 1 1 1 1 1 1 1 1 A cn W.X DATE I 1111111111111111111111 U SOLARMOUNT HD Beam SCALE 1111111111111111111111111111111111 NTS DRAWN BY 11111111111111111111111111111111111 d Z I-_ T Z CO W D Y 0)- Q Z N Zi to J 0 Z z(1) M LLI cn W O > d) Q Z wdi ° U 2 < F– CCQ = U � f� Z LU w COW NC) 0 — W W [\ C Q EL Z W O = T oQ (10om - 0 (D T U) SUPPORT RAIL SPECS 3.000 REV DESCRIPTION DATEI SLOT FOR 1.385 III HEX BOLT 1 1 Jill 'f 1.607 ��l.5 1 1 l 1 I I I 1 1 1 1111 111111111111111111111 A 11111 Y —� 1 1 1 1 1 1 1 1 1 A W.X DATE I 1111111111111111111111 11/3/2014 1 SOLARMOUNT HD Beam SCALE 1111111111111111111111111111111111 NTS DRAWN BY 11111111111111111111111111111111111 AA Dimensions specified in inches unless noted PV -9 9/12/2014 o"UNIRA Project Title: NEGAL RESIDENCE Project ID: 16276428 Name: HERBERT NEGAL Address: 1721 HIDDEN LINKS DR City, State: La Quinta, CA 92253 Module: SunEdison MEMC-13275ACA EW Dimension: 275 Watts Engineering Report I Ptan Review Roof Point Load Up: 298 lbs Roof Point Load Down: 246 lbs Total Number of Modules: 23 Total KW: 6.3 KW Rows/ Columns: 2 / 13 (with gaps) NS Dimension: -155.6 in EW Dimension: -521.7 in Loads Used for Design Module Watts: Wind Speed: 110 mph Ground Snow Load: 0 psf Wind Exposure: C Loads Determined by Zip City, State: La Quinta, CA Wind Speed: 85 mph Ground Snow Load: None psf http://design.unirac.com/tool/project/solarmou nV 16276428/ Unirac - Engineering Report - 16276428 Engineering Report Sept. 12,2014,10:58 a.m. Designed by ALberto@solfusion.net SOLARMOUNT 23 - 275 Watt Panels Inspection HERBERT NEGAL Maximum Rail Span (Zone 1): 79" Selected Rail Span: 48' Product: SOLARMOUNT Module Manufacturer: SunEdison Model: MEMC-P275ACA Module Watts: 275 watts Module Length: 77.80' Module Width: 38.98 " Module Thickness: 1.97 " Module Orientation: Portrait Maximum Rail Cantilever: 16.00 " Expansion Joints: Every 40' Rails Direction: EW Roof Pitch: 7-27° Roof Type: Other 484 ftz 6.3 KWs VYIP& +m :=IJNIRA � HILI I,:iK'r:.a I, , I Ih41''MEr Project Title: NEGAL RESIDENCE Project ID: 16276428 Name: HERBERT NEGAL Address: 1721 HIDDEN LINKS DR City, State: La Quinta, CA 92253 Module: SunEdison MEMC-P275ACA EW Dimension: 275 Watts Engineering Report I Ptan Review Roof Point Load Up: 298 lbs Roof Point Load Down: 246 lbs Total Number of Modules: 11 Total KW: 3.0 KW Rows/ Columns: 2 / 13 (with gaps) NS Dimension: -155.6 in EW Dimension: -281.9 in Loads Used for Design Module Watts: Wind Speed: 110 mph Ground Snow Load: 0 psf Wind Exposure: C Loads Determined by Zip City, State: La Quinta, CA Wind Speed: 85 mph Ground Snow Load: None psf 1/1 1 http://design.unirac.com/tool/projecVsolarmount/16276428/ Unirac - Engineerinq Report - 16276428 Engineering Report Sept. 12, 2014,11 a.m. Designed by Alberto@soLfusion.net SOLARMOUNT 11 - 275 Watt Panels Inspection DESCRIPTION illlllil lillli it illl Maximum Rail. Span (Zone 1): 79' Selected Rail Span: 48• Product: SOLARMOUNT Module Manufacturer: SunEdison Model: MEMC-P275ACA Module Watts: 275 watts Module Length: 77.80 " Module Width: 38.98' Module Thickness: 1.97 " Module Orientation: Portrait Maximum Rail Cantilever: 16.00 " Expansion Joints: Every 40' Rails Direction: EW Roof Pitch: 7-27" Roof Type: Other 232 ftz 3.0 KWs 20750 VENTURA BLVD. SUITE 430 WOODLAND HILLS, CA, 91364 P. 818.924.2485 SOL FUSION. LICENSE NO. 980873 CL: B. C10 S"1G ATLIRE DATE 4 10/31 /1 SUPPORT RAIL CALCULATIONS REV Illi DESCRIPTION illlllil lillli it illl N DATE Iliii .III �Illllllllllllllllll III Illl,lllllllllllllll DATE i illlllllll llllllll llllllli Ill�l l III�I 11/3/2014 11 ii Ilii SCALE IIIIIIIIIII II 111111 111111 NTS IIII IIIIIi DRAWN BY AA W rn U) Q Cn U U - 0 z H- AI Z -0 �.T/Oj W Q a) cn > >, (z� W Y Z IM J z � Q i U7 J z z a) c) W W O >_ cy) w Q z W U Fr Q~ C'3 W Cr C = w 0 Z m Q O — W W D w z w N w .- U) O Er z W o 2 O r om o0 O a C3 Cn SUPPORT RAIL CALCULATIONS REV Illi DESCRIPTION illlllil lillli it illl DATE Iliii .III �Illllllllllllllllll III Illl,lllllllllllllll DATE i illlllllll llllllll llllllli Ill�l l III�I 11/3/2014 11 ii Ilii SCALE IIIIIIIIIII II 111111 111111 NTS IIII IIIIIi DRAWN BY AA ill I PV -1 0 /LSCO Copper Lay -In Ground Lug�� ' @ Dimensions Direct Burial Bg7P !q-�p1 TYPE Features Benefits GBL -DB, L,y-in feature • Provides ease of installation of continuous loop grounding conductor T GBL-4DB • Manufactured from high strength copper • Suitable for direct burial and for use with copper 10 .218 conductors .470 1.15 • Stainless steel 1/4-28 torque screw • Resists oxidation and corrosion in earth or concrete .375 .825 • Rated for 600 volts • Ensures reliability GBL-4DBT* Catalog Number Ground Wire Range Bok Size Dimensions Screw Type C D I EF G H T GBL-4DB 4-14 10 .218 .680 .470 1.15 .19 .375 .825 Slot GBL-4DBT* 4-14 10 .218 .680 .470 1.15 .19 .375 .825 Slot * T denotes tin plating Tested to UL 467, UL File E34440 257 =4730 Madison Road, Cincinnati, Ohio 45227-1426 Phone 513 533-6200 Fax 513 871-4084 Web site www.ilseo.com Canada 1050 Lakeshore Road East, Mississauga, Ontario, Canada L5E1E4 Phone 905 274-2341 Fax 905 274-8763 20750 VENTURA BLVD, SUITE 430 WOODLAND HILLS, CA, 91364 P. 818.924.2485 SOL FUSION. LICENSE NO. 980873 CL: B, C10 S�rTUR�� ���DATE4 � GROUNDING SPECS REV DESCRIPTION DATE DATE 111/3/2014 SCALE NTS DRAWN BY AA PV -1 1 co LO E U) W Q U U � Q Z H a) r Z -a 00 W ( C W Y C cr_ J a) Z Q L,7 J 0 Z z N M W , W O > CLj Q Z w 0 a v Q It 0 w 0 Z w W w m Q w N w a) W Z N Ir Z 02 a M CIE (n GROUNDING SPECS REV DESCRIPTION DATE DATE 111/3/2014 SCALE NTS DRAWN BY AA PV -1 1 CAUTION 20750 VENTURA BLVD. SUITE 430 WOODLAND HILLS, CA, 91364 P. 818.924.2485 POWER TO THIS BUILDING IS ALSO IO. LSO. ICI LICENSSEEKNO. 980873 CL: B, C10 SUPPLIED FROM THE FOLLOWING 1°'3,„4 AT SIGNATURE DATE SOURCES WITH DISCONNECTS LOCATED c HIDDENLINK; DR. AS SHOWN m W Q () U Z H C.L. 70 Al TT Z 0 co W p DRIVE WAY � Z5 U p o >� +- U) W Y cm Z Q J Z AC DISCONNEC Lo o Z z a) C? SERVICE POINT AND ON ROOF J Lu W o > 0) UTILITY METERING Q Z w p U PV SYSTEM DISCONNECT FOR- Q o w p W a o UTILITY OPERATION _ w W w 00 w N w C a) 100A PV LOAD CENTER �� ENPHASE MICRO oz W o r o I Z o = If 00 a U` (n INVERTER DIRECTORY SOLAR PHOTOVOLTAIC _ PLACARD ON ROOF DETAIL \ AC DISCONNECT ON ROOF REV DESCRIPTION DATE ill. illllllll.IIIIII iIII 111111 III II 111111111111111,1111 1.11111 ROOFt l I 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 I I I I I I I ACCESS POINT ” II. 1111111111111111111111 111111 s/z EXISTING BUILDING DATE,11 /3/2014 ii111111111111111111111 i ii i i. SCALE AS NOTED DRAWN BY AA PV-12