Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
BCOM2015-0046
78-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 ,,'� I I I'IIII II'II'III IIII D "1WLIIIIfiI/ 25 VOICE (760) 777-7125 FAX (760) 777-7011 COMMUNITY DEVELOPMENT DEPARTMENT INSPECTIONS (760) 777-7153 BUILDING PERMIT 60 Application Number: BCOM2015-0046 Owner: Property Address: 78315 HIGHWAY 111 HARSCH INV REALTY APN: 604050059 1121 SALMON ST 4TH FL Application Description: HARSH INVESTMENT / LESLIE'S / 3,431SF MERCANTILE TI PORTLAND, OR 92253 Property Zoning: Application Valuation: $100,000.00 Applicant: Contractor: IDEATION DESIGN GROUP (RAVIN CROSBY) rC0V,t4UNITY r -J J C 0 R INC 11881 NORTH 113TH WAY P 0 BOX 26864 SCOTTSDALE, AZ 85259 w 0 2015 OVERLAND PARK, KS 66225 (913)461-8804 DEVEL0P,%1ENTDEPARTP^ENT LIC. No.: 872762 LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, and my License is in full force and effect. License Class: B License No.: 872762 Date: U 4 15- Contractor: Z OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the 1 basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: (_) I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does.the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). (� I, as owner of the property, am exclusively contracting with licensed contractors to construct the project. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State license Law.). ' (_) I am exempt under Sec. . B.&P.C. for this reason Date: Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Lender's Date: 11/10/2015 WORKER'S COMPENSATION DECLARATION I hereby irm under penalty of perjury one of the following declarations: I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier: Polity Number: - I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, if I should become subject to the workers' compensation provisions of Section 3700 of the Labor Code, I shall forthwith corrlply with those provisions. Date: ( O Applicant WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT: Application is hereby made to the Building Official for a permit subject to the conditions and restrictions set forth on this application. 1. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application , the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents, and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter upon the above-mentioned property for inspection purposes. Dae: i c Signature (Applicant or Agent): I LA FINANCIAL INFORMATION DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE :••<,..BSAS 581473. F•EE 101-0000-20306 0 1 $4.00 $4.00 11/10/15 PAID BY J C O R INC METHOD CHECK RECEIPT # MR242 CHECK # 11707 CLTD BY AOR Total Paid for BUILDING STANDARDS ADMINISTRATION BSA: $4.00 $4.00 DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE NON-RESIDENTIAL, EA ADDITION 2,000SF 101-0000-42403 0 $36.26 $36.26 11/10/15 PAID BY METHOD RECEIPT # CHECK # CLTD BY J C O R INC CHECK MR242 11707 AOR DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE NON-RESIDENTIAL, EA ADDITION 2,000SF, PC 101-0000-42600 0 $9.67 $9.67 11/10/15 PAID BY METHOD RECEIPT # CHECK # CLTD BY J C O R INC CHECK C MR242 11707 AOR DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE NON-RESIDENTIAL, FIRST 2,000SF 101-0000-42403 0 $108.77 $108.77 11/10/15 PAID BY METHOD RECEIPT # CHECK # CLTD BY J C O R INC CHECK MR242 11707 AOR DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE NON-RESIDENTIAL, FIRST 2,000SF, PC 101-0000-42600 0 $84.12 $84.12 11/10/15 PAID BY METHOD RECEIPT # CHECK # CLTD BY J C O R INC CHECK MR242 11707 AOR Total Paid for ELECTRICAL - NEW CONSTRUCTION: $238.82 $238.82 DESCRIPTION 4 ACCOUNT QTY AMOUNT PAID PAID DATE CONDENSER/COMPRESSOR 101-0000-42402 0 $72.52 $72.52 11/10/15 PAID BY METHOD RECEIPT # CHECK # CLTD BY J C O R INC CHECK MR242 11707 AOR DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE CONDENSER/COMPRESSOR PC 101-0000-42600 0 $48.34 $48.34 11/10/15 PAID BY METHOD RECEIPT # CHECK # CLTD BY J C O R INC CHECK MR242 11707 AOR DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE VENT FAN 101-0000-42402 0 $60.45 $60.45 11/10/15 PAID BY METHOD RECEIPT # CHECK # CLTD BY J C O R INC CHECK MR242 111707 AOR DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE VENT FAN PC 101-0000-42600 0 $24.15 $24.15 11/10/15 PAID BY METHOD 'r RECEIPT # CHECK # CLTD BY J C O R INC CHECK tMR242 11707 AOR Total Paid for MECHANICAL: $205.46 $205.46 DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE FIXTURE/TRAP 101-0000,;42401 0 $72.54 $72.54 11/10/15 PAID BY, METHOD RECEIPT # CHECK # CLTD BY ' J C O R INC CHECK MR242 11707 AOR DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE .F FIXTURE/TRAP PC 101-0000-42600 0 $72.54 $72.54 11/10/15 PAID BY METHOD RECEIPT# CHECK # CLTD BY J C O R INC CHECK MR242 11707 AOR DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE WATER HEATER/VENT 101-0000-42401 0 $12.09 $12.09 11/10/15 PAID BY METHOD RECEIPT # CHECK # CLTD BY J C O R INC CHECK MR242 11707 AOR DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE WATER HEATER/VENT PC 101-0000-42600 0 $7.25 $7.25 11/10/15 PAID BY METHOD. RECEIPT # CHECK # CLTD BY J C O R INC CHECK MR242 11707 AOR DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE WATER SYSTEM INST/ALT/REP 101-0000-42401 0 $12.09 $12.09 11/10/15 PAID BY METHOD RECEIPT# CHECK # CLTD BY J C O R INC CHECK MR242 11707 AOR DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE WATER SYSTEM INST/ALT/REP PC 101-0000-42600 0 $12.09 $12.09 11/10/15 PAID BY METHOD RECEIPT # . CHECK # CLTD BY J C O R INC CHECK MR242 11707 AOR Total Paid for PLUMBING FEES: $188.60 $188.60 DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE REMODEL, EA ADDITIONAL 500 SF 101-0000-42400 0 $152.25 $152.25 11/10/15 PAID BY METHOD RECEIPT #' CHECK # CLTD BY J C O R INC CHECK MR242 11707 AOR DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE REMODEL, EA ADDITIONAL 500 SF PC 101-0000742600 0 $121.80 $121.80 11/10/15 PAID BY METHOD RECEIPT # CHECK # CLTD BY J C O R INC CHECK MR242 11707 AOR DESCRIPTION ACCOUNT QTY" AMOUNT PAID PAID DATE REMODEL, FIRST 100 SF 101-0000-42400 0 $49.31 $49.31 11/10/15 PAID BY METHOD : ; RECEIPT # CHECK # CLTD BY J C O R INC CHECK MR242 11707 AOR DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE REMODEL, FIRST 500 SF PC 101-0000-42600 0 $134.88 $134.88 11/10/15 PAID BY METHOD RECEIPT # CHECK # CLTD BY J C O R INC CHECK MR242 11707 AOR Total Paid for REMODEL:. $458.24 $458.24 DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE STORAGE RACKS, EA ADDITIONAL 100 LF 101-0000-42404 0 $11.60 $11.60 11/10/15' PAID BY METHOD RECEIPT # CHECK # CLTD BY ....,.J•C.O R INC r CHECK MR242 11707 AOR DESCRIPTION'. ACCOUNT QTY: AMOUNT PAID PAID DATE STORAGE RACKS, FIRST 100 LF 101-0000-42404 0 $24.66 $24.66 11/10/15 PAID. BY METHOD RECEIPT # CHECK # CLTD BY J C O R INC CHECK MR242 11707 AOR DESCRIPTION ACCOUNT QTY AMOUNT: PAID PAID DATE STORAGE RACKS, FIRST 100 LF PC 101-0000-42600 0 $95.72 $95.72 11/10/15 PAID BY ' METHOD 'RECEIPTr# CHECK # CLTD BY.. 1 C O R INC CHECK MR242 11707 AOR Total Paid for STORAGE RACKS: $131.98 $131.98 DESCRIPTION ACCOUNT QTY AMOUNT PAID.. PAID DATE SMI - COMMERCIAL 101-0000-20308 0 $28.00 $28.00 11/10/15 PAID BY. METHOD RECEIPT # CHECK # CLTD BY 1 C O R INC CHECK MR242 11707 AOR Total Paid for STRONG MOTION INSTRUMENTATION SMI: $28.00 $28.00 Description: HARSH INVESTMENT/ LESLIE'S / 3,431SF MERCANTILE TI Type: BUILDING, COMMERCIAL Subtype: REMODEL Status: ISSUED Applied: 8/27/2015 PJU Approved: 11/10/2015 AOR Parcel No: 604050059 Site Address: 78315 HIGHWAY 111 LA QUINTA,CA 92253 Subdivision: PM 19028 Block: Lot: 3 Issued: 11/10/2015 AOR Lot Sq Ft: 0 Building Sq Ft: 0 Zoning: Finaled: Valuation: $100,000.00 Occupancy Type: Construction Type: Expired: 5/8/2016 AOR No. Buildings: 0 No. Stories: 0 No. Unites: 0 E-MAIL Details: 3,431SF MERCANTILE TENANT IMPROVEMENT/M-OCC/91-OL/NON-SPRINKLED [LESLIE'S POOL SUPPLIES] COMBINES SUITES M (78- 329), N (78-321) AND P (78-315) AND CREATES TWO CONTROLS AREAS THAT ARE SEPARATED FROM EACH OTHER AND THE REMAINING SUITE WITHIN THE SHELL BUILDING. THIS PERMIT DOES NOT INCLUDE BUILDING SIGNAGE, CHANGE IN USE OR EVALUATION OF THE ENTIRE SHELL BUILDING. 2013 CALIFORNIA BUILDING CODES. 75 0 Applied to Approved Approved to Issued ADDITIONAL CHRONOLOGY CHRONOLOGY TYPE STAFF NAME ACTION DATE COMPLETION DATE NOTES EMAIL RECEIVED FROM JUSTIN SLATER FROM IDEATION E-MAIL AJ ORTEGA 10/28/2015 11/2/2015 DESIGN GROUP, REVIEWED AND APPROVED ATTACHMENTS, WILL SCHEDULE CONTRACTOR TO MEET WITH ME TO SLIP - SHEETS DRAWINGS AND ISSUE PERMIT. PHONED RAVIN CROSBY THAT PLANS ARE READY FOR PLAN CHECK CORRECTIONS, HE WILL GET BACK TO ME WITH CARRIER- ARRIERPICKUP COMPLETE/READY FOR PICK AJ ORTEGA 9/17/2015 9/17/2015 PICKUPINFORMATION, SENT REVIEW COMMENTS VIA EMAIL UP (RCROSBY@IDEATIONDG.COM) EMAILED RAVIN CROSBY (RCROSBY@IDEATIONDG.COM) PLAN CHECK THAT PLANS HAVE TWO OUTSTANDING *ITEMS ALONG WITH COMPLETE/READY FOR PICK AJ ORTEGA 10/22/2015 10/22/2015 A FEW MISCELLANEOUS ITEMS THAT REQUIRE REVISIONS UP PRIOR TO APPROVAL, SEE ATTACHED EMAIL FOR SECOND REVIEW COMMENTS. PLAN CHECK SENT TO KAY HENSEL 10/12/2015 10/12/2015 STRUC TO YOUNG - DUE 10/19/2015 OUTSIDE PC Printed: Tuesday, November 10, 2015 10:24:48 AM 1 of 7 PLAN CHECK SUBMITTAL RECEIVED PHILIP JUAREZ 8/21/2015 8/21/2015 RECIEVED AT END OF BUSINESSW DAY.: CONDITIONS CLTD DESCRIPTION ACCOUNT CITY AMOUNT PAID PAID DATE RECEIPT # CHECK # METHOD PAID BY BY BSAS SB1473 FEE 101-0000-20306 0 $4.00 $4.00 11/10/15 MR242 11707 CHECK J C O R INC AOR Total Paid for BUILDING STANDARDS ADMINISTRATION $4.00 $4.00 BSA: CONTACTS 101-0000-42403 0 NAME TYPE NAME ADDRESSI CITY STATE ZIP PHONE FAX EMAIL APPLICANT IDEATION DESIGN GROUP (RAVIN CROSBY) 11881 NORTH 113TH WAY SCOTTSDALE AZ 85259 RCROSBY@IDEATIOND G.COM ARCHITECT DAVID UDKOW ARCHITECT 11881 NORTH 113TH WAY SCOTTSDALE AZ 85259 11/10/15 MR242 DAVIDAUDKOW@COX. NET CONTRACTOR J C O R INC P O BOX 26864 OVERLAND PARK KS 66225 OWNER HARSCH INV REALTY 1121 SALMON ST 4TH FL PORTLAND OR 92253 101-0000-42403 0 $108.77 Printed: Tuesday, November 10, 2015 10:24:48 AM 2 of 7 ......... FINANCIAL INFORMATION CLTD DESCRIPTION ACCOUNT CITY AMOUNT PAID PAID DATE RECEIPT # CHECK # METHOD PAID BY BY BSAS SB1473 FEE 101-0000-20306 0 $4.00 $4.00 11/10/15 MR242 11707 CHECK J C O R INC AOR Total Paid for BUILDING STANDARDS ADMINISTRATION $4.00 $4.00 BSA: NON-RESIDENTIAL, EA 101-0000-42403 0 $36.26 $36.26 11/10/15 MR242 11707 CHECK J C O R INC AOR ADDITION 2,000SF NON-RESIDENTIAL, EA 101-0000-42600 0 $9.67 $9.67 11/10/15 MR242 11707 CHECK J C O R INC AOR ADDITION,2,000SF, PC NON-RESIDENTIAL, 101-0000-42403 0 $108.77 $108.77 11/10/15 MR242 11707 CHECK J C O R INC AOR FIRST 2,000SF NON-RESIDENTIAL, 101-0000-42600 J0 $84.12 $84.12 11/10/15 MR242 11707 CHECK J C O R INC AOR FIRST 2,000SF, PC Total Paid for ELECTRICAL - NEW CONSTRUCTION: $238.82 $238.82 CONDENSER/COMPR ES 101-0000-42402 0 $72.52 $72.52 11/10/15 MR242 11707 CHECK J C O R INC AOR SO R , Printed: Tuesday, November 10, 2015 10:24:48 AM 2 of 7 ......... Printed: Tuesday, November 10, 2015 10:24:48 AM 3 of 7 ICIRW------ CLTD DESCRIPTION ACCOUNT CITY AMOUNT PAID PAID DATE RECEIPT # CHECK # METHOD PAID BY BY CONDENSER/COMPRES 101-0000-42600 0 $48.34 $48.34 11/10/15 MR242 11707 CHECK J C O R INC AOR SOR PC VENT FAN 101-0000-42402 0 $60.45 $60.45 11/10/15 MR242 11707 CHECK J C O R INC AOR VENT FAN PC 101-0000-42600 0 $24.15 $24.15 11/10/15 MR242 11707 CHECK J C O R INC AOR Total Paid for MECHANICAL: $205.46 $205.46 FIXTURE/TRAP 101-0000-42401 0 $72.54 $72.54 11/10/15 MR242 11707 CHECK J C O R INC AOR FIXTURE/TRAP PC 101-0000-42600 0 $72.54 $72.54 11/10/15 MR242 11707 CHECK J C O R INC AOR WATER HEATER/VENT 101-0000-42401 0 $12.09 $12.09 11/10/15 MR242 11707 CHECK J C O R INC AOR WATER HEATER/VENT 101-0000-42600 0 $7.25 $7.25 11/10/15 MR242 11707 CHECK J C O R INC AOR PC WATER SYSTEM 101-0000-42401 0 $12.09 $12.09 11/10/15 MR242 11707 CHECK J C O R INC AOR INST/ALT/REP WATER SYSTEM 101-0000-42600 0 $12.09 $12.09 11/10/15 MR242 11707 CHECK J C-0 R INC AOR INST/ALT/REP PC Total Paid for PLUMBING FEES: $188.60 $188.60 REMODEL, EA 101-0000-42400 0 $152.25 $152.25 11/10/15 MR242 11707 CHECK J C O R INC AOR ADDITIONAL 500 SF REMODEL, EA 101-0000-42600 0 $121.80 $121.80 11/10/15 MR242 11707 CHECK J C O R INC AOR, ADDITIONAL 500 SF PC REMODEL, FIRST 100 SF 101-0000-42400 0 $49.31 $49.31 11/10/15 MR242 11707 CHECK J C O R INC AOR REMODEL, FIRST 500 SF 101-0000-42600 0 $134.88 $134.88 11/10/15 MR242 11707 CHECK J C.0 R INC AOR PC Total Paid for REMODEL: $458.24 $458.24 STORAGE RACKS, EA 101-0000-42404 0 $11.60 $11.60 11/10/15 MR242 11707 CHECK J C O R INC AOR ADDITIONAL 100 LF STORAGE RACKS, FIRST 101-0000-42404 0 $24.66 $24.66 11/10/15 MR242 11707 CHECK J C O R INC AOR 100 LF Printed: Tuesday, November 10, 2015 10:24:48 AM 3 of 7 ICIRW------ INSPECTIONS PARENT PROJECTS CLTD DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE RECEIPT # CHECK # METHOD PAID BY BY STORAGE RACKS, FIRST 101-0000-42600 0 $95.72 $95.72 11/10/15 MR242 11707 CHECK JC O R INC AOR 100 LF PC SEE ATTACHED COMPLETE REVIEW COMMENTS. . 1ST PLANNING (2 JAY WUU 9/1/2015 9/16/2015 9/11/2015 READY FOR APPROVAL Total Paid .for STORAGE RACKS: $131.98 $131.98 SMI - COMMERCIAL 101-0000-20308 0 $28.00 $28.00 11/10/15 1 MR242 11707 CHECK J C O R INC AOR Total Paid for STRONG MOTION INSTRUMENTATION SMI: $28.00 $28.00 INSPECTIONS Printed: Tuesday, November 10, 2015 10:24:48 AM 4 of 7 ���% ....... PARENT PROJECTS NOTES REVIEW TYPE REVIEWER SENT DATE DUE DATE RETURNED REVIEWS STATUS- REMARKS DATE 1ST BLDG NS (2 WK) AJ ORTEGA 9/1/2015 9/16/2015 9/17/2015 REVISIONS REQUIRED SEE ATTACHED COMPLETE REVIEW COMMENTS. . 1ST PLANNING (2 JAY WUU 9/1/2015 9/16/2015 9/11/2015 READY FOR APPROVAL WK) APPLICANT REFERRED TO RIVERSIDE COUNTY FIRE FOR PLAN APPROVAL October 22, 2015 RE: TENANT IMPROVEMENT PLAN CHECK -Non Structural LAQ-I5-TI-027 Leslie's Swimming Pool supplies 78315 Hwy 111 La Quinta, CA You have been approved for a tenant improvement on an existing building. THIS IS NOT AN OCCUPANCY PERMIT. S THE FOLLOWING CONDITIONS MUST BE MET PRIOR TO INSPECTION: Printed: Tuesday, November 10, 2015 10:24:48 AM 4 of 7 ���% ....... FIRE FIRE BUCKET 9/10/2015 1 9/16/2015 10/23/2015 APPROVED Install door hardware and exit signs as per Chapter 10 of the 2013 CBC. A minimum 2A10BC Fire Extinguisher, (State Fire Marshal Approved) must be mounted in a visible location within 75' walking distance from any point in your building or suite. Fire extinguishers can be installed by a licensed extinguisher company with a State Fire Marshal service tag attached to the extinguisher, or purchased from a retail store with a sales receipt attached. A licensed fire extinguisher company must service extinguisher yearly. All breakers must be labeled and a clearance of 36 inches must be maintained around the panel at all times. Approved suite addresses shall be placed in such a position to be plainly visible and legible from the street. Said numbers shall contrast with their background. A durable sign stating "This door to remain unlocked during business hours" shall be placed on or adjacent to the front exit door. The sign shall be in letters not less than one inch high on a contrasting background. Provide key(s) to the tenant space for inclusion in the main building Knox Box. Key(s) shall have durable and legible tags affixed for identification of the correlating tenant space. Key(s) shall be provided at time of final inspection. SUBJECT TO FIELD INSPECTION - Nothing in our review shall be construed as encompassing I I I I structural integrity. Review of this plan does not authorize or approve any omission or deviation Printed: Tuesday, November 10, 2015 10:24:48 AM 5 of 7 from all applicable regulations. Final approval is subject to field inspection. Applicant/installer shall be responsible -to contact the Fire Department to schedule inspections. A re -inspection fee will be required if more than one (1) inspection is necessary. Requests for inspections are to be made at least 72 hours in advance and may be arranged by calling (760) 863 8886. All questions regarding the meaning of these conditions should be referred to the Fire Department Planning & Engineering Staff at (760) 863 8886. Sincerely, Ronald Griesinger Fire Safety Specialist TYPE OF CONSTRUCTION AND WATER CLOSET 2ND BLDG NS (1 AJ ORTEGA 10/12/2015 10/19/2015 10/22/2015 REVISIONS REQUIRED ACCESSIBILITY - W/ MISCELLANEOUS ITEMS FIRE WK) APPROVAL, CONTRACTOR INFORMATION, ENERGY FORMS. - ALTHOUGH THIS IS A RESUBMITTAL, STRUCTURAL 2ND BLDG STR (1 YOUNG 10/12/2015 10/19/2015 10/20/2015 READY FOR APPROVAL CALCS FOR RACKING, ROOF TOP EQUIPMENT AND WK) ENGINEERING INTERIOR SHELVING WERE REQUESTED AFTER THE FIRST PLAN CHECK 3RD BLDG NS (1I AJ ORTEGA I 11/10/2015 I 11/12/2015 I 11/10/2015 I APPROVED I I MET WITH CONTRACTOR TO ORAI-SHEET L REVISED DAY) Printed: Tuesday, November 10, 2015 10:24:48 AM 6 of 7 IC ........ Printed: Tuesday, November 10, 2015 10:24:48 AM 7 of 7 ATTACHMENTS Attachment Type CREATED OWNER DESCRIPTION PATHNAME _ SUBDIR ETRAKIT ENABLED BCOM2015-0046 - 2ND 2ND REVIEW COMPLETE REVIEW COMPLETE DOC 10/22/2015 AJ ORTEGA CORRECTIONS (EMAIL) CORRECTIONS 0 (EMAIL).pdf 1ST REVIEW . BCOM 2015-0046 -1ST DOC 10/20/2015 KATHRYN SAMUELS STRUCTURAL REVIEW STRUCTURAL 0 TRANSMITTAL TRANSMITTAL.pdf Printed: Tuesday, November 10, 2015 10:24:48 AM 7 of 7 Piq�wau /I/ Bin .# City Of La Qui[1ta Building 8t SaMVI Ai lon P.O. Box 1504,78-495 Calle Tampico La.Quinta, CA 92253 -:(760) 777-7012 Building Permit •Application and Tracking Sheet Permit # Cb1v� Project Add � 14#V H/ I-& &vtnTA 6AIL253 Owner'sName:./{af44 %rtt/es w,6-4�,I A. P. Number. Address: o f y c l 9/ k I,V a I( Legal Description: b '— OS "' City, ST, Zip: t:A Contactor rap Telephone: (iD -7?4 j 5$ O 3}4 Address: Project Description: 444 ,11.'f City, ST, Zip: D Ct✓-% eXi Telephone r s -:y State Lic. # : City Lic. #.: ' Arch., Engr., Designerkip w �IAJ Address: Mmrtk 115", w City, ST, Zip: Sce- dal 1 c 'Az- 06a,61 ,I)( - Telephone: L4 53� 5' Y'' �a > Construction Type:. V Occupancy: State Lic. #:G ^�' 1 :z :, _~; .:„:,.:.. ;w ":..""`<`;✓,''�' Project type (circle one): New Add'a Alte Repair\ Demo Name of G' tact Person: l! l vt G r©S 6 Sq. Ft.: 3 #Stories: # Units: Telephone # ; ^ntactPerson: ,(p0dN' q. ( 3 Estimated Value of Project: �� 60 O ' APPLICANT: DO NOT WRITE BELOW THIS LINE # Submittal Req'd Reed-] TRACKING—_•_•._- • PERMTI'FEES- Plan Sets , Plan Cheek submitted Item Amount Structural Cases. Reviewed, ready for corrections Plan Check Deposit. . Truss Calcs. Called Contact Person Plan Check Balance Tide 24 Cates.< ' Plans picked u G5641 VIA- J F Construction Flood plain plan Plansresnbmi Mechanical Grading plan tad Review, ready for correctionMiissue Electrical Subcontactor List Called Contact Person Plumbing Grant Deed Plans picked up S.M.I. LLOAL Approval Plans resubmitted Grading IN HOUSE:- 3" Review; ready for corrections!' aDeveloper Impact Fee Planning Approval. Called Contact Person A.LP.P. Pub. Wks. Appr :. Date of permit issue• AVJ School Fees Total Permit Fees YOUNG o h ENGINEERING, � a Ra �u. a a Letter of Transmittal To: City of La Quinta Today's Date: 10-20-15 78-495 Calle Tampico City Due Date: 10-19-15 La Quinta, CA 92253 Project Address: 78-315 Highway 111 - Attn: Kay Plan Check #: BCOM 2015-0046 Submittal: ® 1st ❑ 4th ❑ 2nd ❑ 5th ❑ 3'd ❑ Other: We are forwarding: ® By Messenger. ❑ By Mail (Fed Ex or UPS)., ❑ Your Pickup Includes: # Of Descriptions: Y Includes: # Of Descriptions: Copies: Copies. ® 2 Structural Plans ❑ Revised.StructuralPlans ® 2 Structural Calculations ❑ Revised Struct. Calcs Truss Calculations Floor ❑ and Roof ❑ Revised Truss ❑ Soils Report ❑ Revised Soils Report ❑ Structural Comment List " ❑ Approved Structural Plans El Redlined Structural Plans ❑ Approved Structural Calcs ❑ Redlined Structural Calcs ❑ Approved Truss Calcs ❑ Redlined Truss Calcs ❑ Approved Soils Report , Redlined Soils Reports ❑ Other: Comments: Structural content is approvable. If you have any questions, please call. Time = 1.75 HR This Material Sent 'for: ❑ - Your Files ® Per Your Request ❑ Your Review ❑ Approval a ❑ Checking ❑ At the request of: i Other: ❑, By: . Kathryn Samuels " Palm Desert Office:' ® (760) 772-5107 Other: ❑ Permit Number: BCOM2015-0046 Description: HARSH INVESTMENT REALTY TENANT IMPROVEMENT Applied: 8/27/2015 Approved: Site Address: 78315 HIGHWAY 111 Issued: Finaled: City, State Zip Code: LA QUINTA, CA 92253 Status: UNDER REVIEW Applicant: DAVID UDKOW ARCHITECT Parent Permit: Owner: HARSCH INV REALTY Parent Project: Contractor: TBD Details: LIST OF REVIEWS .RETURNED" SENT DATE DUE- DATE TYPE CONTACT STATUS REMARKS. DATE Review Group: BLDG 1ST (2WK) 9/1/2015 9/16/2015 1ST BLDG NS (2 WK) BUILDING BUCKET Notes 9/1/2015 9/16/2015 1ST PLANNING (2 WK) PLANNING BUCKET Notes: Printed: Tuesday, 01 September, 2015 1 of 1R SYSTEMS LESLIE'S SWIMMING POOL SUPPLIES Hazardous Materials Management Plan Retail Facilities SIC Code: General Information RECEIVED Business Name: Leslie's Swimming Pool Supplies 2-6 (Seasonal) Phone Number: TBD OCT 12 2015 Address: 78-041 Hwy 111; Ste. 315,321 & 329 CITY OF LA QUINTA � COMMUNITY DEVELOPMENT La Quinta, CA 92253 Store Manager: TBD Emergency Contacts: 1) TBD, District Manager Wk: Cell: 2) Mike Jennings, Director, Safety/Regulatory Affairs Wk: 602-366-3946 Cell: 480-227-9249 3) Mark Lum, Vice President, Risk Management Wk: 602-366-3849 Cell.: 480-227-3146 Corporate Address: Leslie's Poolmart, Inc. 2005 E. Indian School Rd. Phoenix, AZ 85016 Primary Contact: Mike Jennings, Director, Safety/Regulatory Affairs Business Activity: Retail sale of swimming pool and spa supplies SIC Code: 5999 Dun & Bradstreet #: 05-010-6095 Number of Employees: 2-6 (Seasonal) Number of Shifts: 1 Hours of Operation: 9 A -M. — 5-R P M CITY OF LA QUINTA BUILDING & SAFETY DEPT. APPROVED FOR CONSTRUCTION �0iS8Y�— Prepared by: Signature: Date: Name: Mike Jennings Title: Director, Safety/Regulatory Affairs Prepared in accordance with CFC 2013 1 LESLIE'S SWIMMING POOL SUPPLIES Hazardous Materials Management Plan Retail Facilities General Facility Description/Site Plan The store encompasses approximately 3,431 square feet. This location has approximately 2,636 square feet of retail retail'sales area and approximately 426 square feet of staging area. Separation between the retail sales area and the staging area is 1 -hour rated, allowing for two "control areas" for the storage of hazardous materials. The facility is not equipped with an automatic fire sprinkler system. A facility map is provided immediately below. Prepared in accordance with CFC 2013 2 LESLIE'S SWIMMING POOL SUPPLIES Hazardous Materials Management Plan Retail Facilities Hazardous Material Inventory Statement (HMIS) Attachment B hereto provides detail regarding hazardous materials stored at Leslie's. The following table provides Leslie's typical estimated maximum operating quantities, by hazard class, as well as the Maximum Allowable Quantities (MAQ) per the 2013 California Fire Code (CFC). Quantities reflected are in pounds for solids and gallons for liquids. Hazardous Material Storage and Handling Hazardous materials are stored and handled in final consumer packaging. Employees receive initial and recurrent training on the safe and proper handling and storage of hazardous materials onsite. Incompatible hazardous materials are separated either by distance or non-combustible barrier. Hazardous material storage and display areas are monitored by employees throughout the day. Prepared in accordance with CFC 2013 3 Leslie's Estimated Maximum Operating Quantities (Lbs./Gal.) Maximum Allowable Quantities (MAQ) per 2013 CFC, Tables 5003.11.1 & 5704.3.4.1 (CBC Table 414.2.5(1)) Retail Control Area Staging Control Area Non-Sprinklered Control Area (Lbs./Gal.) Class 1 Oxidizer 10,033/0 2,000/0 18,000/1,800 Class 2 Oxidizer 124/0 0/0 2,250/225 Class 3 Oxidizer 1,150/0 1,150/0 1,150/115 Water Reactive 1 8,033/0 2,000/0 Not Limited Unstable Reactive 1 1,150/0 1,150/0 Not Limited Corrosive 1,600/28 0/420 9,750/975 Flammable/Com- bustible (Not IA) 0/0 0/54 NA/1,600 Combustible IIIB 1 0/81 1 0/25 NA/13,200 Hazardous Material Storage and Handling Hazardous materials are stored and handled in final consumer packaging. Employees receive initial and recurrent training on the safe and proper handling and storage of hazardous materials onsite. Incompatible hazardous materials are separated either by distance or non-combustible barrier. Hazardous material storage and display areas are monitored by employees throughout the day. Prepared in accordance with CFC 2013 3 LESLIE'S SWIMMING POOL SUPPLIES Hazardous Materials Management Plan Retail- Facilities Employee Training.and Safety Equipment Mandated training is conducted for all new hires and at required intervals for all employees. Monthly safety meetings are conducted covering an array of topics including: Hazard Communication (MSDS, product labels), Fire Prevention/Housekeeping, Safe Chemical Storage and Handling, Emergency Evacuation/Response, Fire Extinguishier Identification/Use and Chemical Spill Procedures. The facility is equipped with fire extinguishers (water, dry chemical) and has a designated safety area with the following safety equipment: • Safety Cabinet containing safety goggles/glasses, chemical resistant gloves and N95 filtering facepiece respirators. • Dedicated chemical spill broom, dustpan and mophead • 55 -gallon poly overpack • 5 -gallon poly safety containers • Hazard tape • Caution cone Site Security and Monitoring Methods The facility is protected by a security system with 24 hour monitoring. Exterior doors are secured against unauthorized entry and customers are not allowed access beyond the sales area. Visual monitoring of the facility, including hazardous material storage areas, is made multiple times throughout the day. Emergency. Response In the event of an emergency that presents an immediate and serious danger to the health and welfare of employees, customers, and/or neighboring occupancies, facility management is trained to: 1) Evacuate the premises and neighboring occupancies, if necessary; 2) Notify local emergency response agencies; .3) Contact Leslie's Risk Management Department; 4) Remain available to provide liaison with local emergency responders. Facility management is trained to address small, incidental spills of hazardous materials in accordance with posted Chemical Spill Procedures. Large spills or spills that are deemed to be a hazard to people, property and /or the environment will be handled by a third -party emergency response team and/or local emergency response personnel. Prepared in accordance with CFC 2013 4 Leslie's Swimming Pool Supplies No. 468 La Quinta,•CA 12044 Chlor Brite 1 Lb 12055 12061 Chlor Brite 8 Lbs Chlor Brite 25 Lbs 12064 Chlor Brite 40 Lbs 48173 Spa Chlor Brite 2 Lbs acid (12-18) i Bifluoride Total 12100 Floating Chlorinator 4 Lbs 12156 1" Chlor Tabs 8 Lbs 12160 1" Chlor Tabs 20 Lbs 12165 1" Chlor Tab 35 Lbs 12423 3" Jumbo Tabs 7 Lbs 12427 3" Jumbo Tabs 20 Lbs 12437 3" Jumbo Tabs 35 Lbs 12611 Mighty Tabs 7 Lbs 12612 Mighty Tabs 35 Lbs Total 12500 Genesis Shock 10 Oz 12502 Genesis Shock 10 Pack Total 14015 Muriatic Acid Gal (2X1) Total 14790 SCALE-B-GON 14825 Total Tile Cleaner Qt Total 1 8 25 40 2 4 8 20 35 7 20 35 7 35 0.625 6.25 2 0.25 1M1I6 F!„ Hazardous Materials Inventory Statement (HMIS) Sodium dichloro-s-triazinetrione Dihydrate (98-100) Sodium Chloride (0.1-1) Trichloro-s-triazinetrione (98-100) Boric Acid (0-1) Trichloro-s-triazinetrione (67) Privileged and Confidential 51580-86-0 I S I Class 1 Oxidizer 7647-14-5 87-90-1 10043-35-3 S I Class 1 Oxidizer 87-90-1 1 S I Class 1 Oxidizer Acid (25-36) 7647-01-0 L Corrosive acid (12-18) i Bifluoride 7647-01-0L 1341-49-7 Combustible IIIB Corrosive uric acid tric Acid 7647-01-0 7664-38-2 L Corrosive 907, 192 600 960 96 2,750 24 96 240 420 420 1,920 5,600 42 140 8,902 94 38 131 216 216 3 3 - OCT 12 2015 CITY OF LA QUINTA Product stored in final consumer packaging (i.e. plastic pouches/containers) at ambient pressure and temperatuGQMMUNITY DEVELOPMENT 1 of 4 6 6 Leslie's Swimming Pool Supplies No. 468 'Hazardous Materials Inventory Statement (HMIS)Privileged and Confidential La Quinta, CA y 14012 Black Algae Killer Qt 0,25 Basic Copper Carbonate Quaternary Ammonium Compounds, Benzyl -C 1 2-16-Alky Alcohol Denat Ethanolamine Triethanolamine • 12069-69-1 68424-85-1 64-17-5 141-43-5 102-71-6 L Corrosive • 3 14021 Black Algae Killer 1/2 Gal 0.5 7 Total 10 14025 Algae Control Qt 0.25 Proprietary 14028 Algae Control 1/2 Gal 0.5 L Combustible IIIB 27 14030 Algae Control Gal 1 24 24 Total 75 48102 Brom Tabs Spa 1.5 Lbs 1.5 1,3 Dichloro-5, 5 -Dimethyl -Hydantoin 1,3 Dichloro-5, Ethyl -5 -Methyl Hydantoin 1-bromo-3-chloro-5,5-dimethylhydantoin Sodium Chloride 118-52-5 89415-87-2 16079-88-2 7647-14-5 S Class 2 Oxidizer 36 48105 Brom Tabs Spa 4 Lbs 4 64 Total 100 14670 Power Powder Plus 1 Lb 1 Calcium Hypochlorite (>70) Calcium Chlorate (2-3) Calcium Carbonate (2) Calcium Hydroxide (2) Lanthanum Carbonate (0-0.8) 7778-54-3 10137-74-3900 471-34-1 1305-62-0 6487-39-4 S Class 3 Oxidizer Unstable Reactive 1 14183 Power Powder Plus 25 Lbs 25 600 Total 1,500 14190 Power Powder Granular 50 Lbs 50 Calcium Hypochlorite Sodium Chloride Calcium Chlorate Calcium Chloride Calcium Hydroxide Calcium Carbonate 7778-54-3 7647-14-5 10137-74-3 10043-52-4 1305-62-0 471-34-1 S S - Class 3 Oxidizer Unstable Reactive 1 600 14191 Power Powder Granular 100 Lbs 100 200 Total 800 14626 Chlor Boost 1 Lb. 1 Calcium Hypochlorite (40-55%) Sodium Chloride (5-15%) Calcium Chlorate (04%) Calcium Chloride (04%) Calcium Hydroxide (0-5%) Calcium Carbonate (0-4%) Magnesium Sulfate Heptahydrate( 25-35%) 7778-54-3 7647-14-5 10137-74-3 10043-52-4 1305-62-0 471-34-1 10034-99-8 Class 1 Oxidizer 250 Total 250 Product stored in final consumer packaging (i.e. plastic pouches/containers) at ambient pressure and temperatures. 2 of 4 Leslie's Swimming Pool Supplies No. 468 Hazardous Materials InventoryStatement HMIS La Quinta, CA ( ) Privileged and Confidential •I 14390 ,•_ Butoxyethanol Spray & Rinse 0.125 Poly(oxy-1,2-ethanediyl),alpha(nonylphenyl)- Etidronic Acid Citric Acid • • 111-76-2 9016-45-9 2809-21-4 L Combustible IIIB 3 77.92.9 Total ' ' 3 14400 SAND FILTER REVITALIZER QT 0.25 Citric Acid ETIDRONIC ACID Butoxyethanol POLY(OXY-1,2-ETHANEDIYL),- ALPHA(NONYLPHENYL) 77.92.9 2809-21-4 111-76-2 9016-45-9 L Corrosive 3 Total 14238 ChlorinatingLiquid Gal 2X1 4 ( ) 2 Sodium hypochlorite (10-15) 7681-52-9 L Corrosive 9 216 Total 14540 Fresh N Clear 1 Lb216 Fresh N Clear 25 Lbs Fresh N Clear 40 Lbs Fresh N Clear Lbs 1 25 40 2 Oxone Monopersulfate Compound (80-100) Sodium Carbonate (0-20) 14546 70693-62-8 497-19-8 S Corrosive 772 14547 300 14550 480 Total 48 1,600 15363 Frog Spa Bromine Cartridges 1 1-bromo-3-chloro-5,5-dimethyl h yd antoin (96) 16079-88-2 S Class 2 Oxidizer 24 Total 26550 Patio Perfect Prairie Sand Gal Patio Perfect Smooth Cream Gal Patio Perfect Desert Tan Gal Patio Perfect Stone Creek Gal 1 1 1 1 Butoxy dipropanol (1.55) Ethylene Glycol (2.10) 24 26551 29911-28-2 107-21-1 L Combustible IIIB Irritant 2 26552 8 26553 2 Total 2 26640 Dura Seal White Gal14 Dura Seal Ice Blue Gal Dura Seal Blue Heaven Gal 1 1 1 Aromatic naphtha (3.82) 2-Butoxyethanol (0-1.7) Butoxy Propanal (0-.9) 26641 64742-95-6 111-76-2 1569-01-3 Combustible II Irritant 8 26642 4 Total 12 24 26648 Prime It (Base) Gal Prime It (Catalyst) Qt 1 0.25 Base Butoxy propanol (6.6) 2-Butoxyethanol (4) Catalyst Non -Hazardous 1569-01-3 111-76-2 - L Combustible II 12 3 26648 Total 15 Product ' stored in final consumer packaging (i.e. plastic pouches/containers) at ambient pressure and temperatures. 3of4 Leslie's Swimming Pool Supplies No. 468 Hazardous Materials Inventory Statement HMIS La Quinta, CA ry ( ) Privileged and Confidential Product stored in final consumer packaging (i.e. plastic pouches/containers) at ambient pressure and temperatures. 4 of 4 1 5 8' BASE PLATE DETAIL (1)-112"0 ANCHOR BOLT PER BASE PLATE 3 1 /4- EMB., (SEE NOTE NO. 4) 99" &� 51" 1`P s a a • i b: • ' i R h r d. i 42" I f IL no FRONT VIEW SIDE VIEW 24" ri A BOTH SIOE TYP SEC, B-B 11 BRACING DETAIL R iY I{I � � 7f 16"0 RIVET A5TM A576-908I HOT —WROUGHT UNS G10100 GRADE C-1010 2t_�3 PIN CONNECTION 4—.f lu 31 GENERAL CONFIGURATION CITY OF LA Q U I lT BUILDING & SAFETY DEPT, APPROVED FOR CON TRUCTiCN [SATE 1 * r BY . & NOTES: 1 —DESIGN OF STEEL STORAGE RACKS AS SHOWN RY THESE DRAWINGS AND CALCULATIONS ARE IN COMPLIANCE WITH THE REQUIREMENTS OF THE CRC 2013, ASCE SEI 7-10, ACI 318-1 1, RV I/ANSI MH 16.1 :2008 2--STEEL FOR ALL SHAPES FY=55 KSI. ASTM A1011 GR.55 (EXCEPT AS NOTED) 3—CEO FIELD WELDING IN THIS PROJECT ALL WELDED CONSTRUCTION IN THE SHOP OF THE APPROVED FABRICATOR #00777 (E70-XX ELECTRODES) 4—ALL ANCHORS LISTED BELOW ARE ACCEPTABLE FOR THIS PROJECT, HILTI KWIK DOLT—T7 E5R-1917, HILTI KWIK HUS—EZ SCREW ESR-3027 POWERS ED1 ESR-2818, POWERS Sot ESR-2502, POWERS SCREW ESR-2526 SIMPSON STRONG BOLT 2 ESR-3037, SIMPSON TITAN HD SCREW ESR-2713 ETW RED HEAD ESR-2427 SPECIAL INSPECTION IS REQUIRED 5—CONCRETE SLAB 6" THICK 2500 PSI. SOIL REARING CAPACITY 1000 PSF 6—STORAGE RACK CAPACITY: 1500 % LEVEL mw�r 7—RACK INSTALLATIONS SHALL DISPLAY IN ONE OFF MORE CONSPICUOUS LOCATIONS .momp A PERMANENT SIGN OF 50 SQUARE INCHES IN AREA. SHOWING THE CAPACITY �.. OF THE RACK (1500 # f LEVEL) 8—STORAGE RACKS SHALL BE INSTALLED WITH A MAXIMUM TOLERANCE FROM THE VE FRTICAL OF 1 /2" IN 10'-0°" OF HEIGHT 9--THE CLEAR SPACE BELOW SPRINKLERS SHALL BE A MINIMUM OF 18 INCHES BETWEEN THE TOP OF THE STORAGE AND THE CEILING SPRINKLER DEFLECTOR, 10—STOf ACE BACK AREA NOT OPEN TO PUBLIC, IrMPL , _ACCESS ONLY lxtCEIVED OCT 12 r'xi11fly RACK DESIGN AND EI EERi 0 412 WEST BROADWAY SUITE #244 GLENDALE CA. 91204 y � SCALE, NONE DRAWN BY: S.N.J. ua 19o-COs3524L m €7A7E. 9-19-15 s�� ecr, LESLIE'S POOL SUPPLIES #468 Cl � , 78-315 HIGHWAY 111, LA 0UINTA, CA 92253 OF STORAGE RACK DETAILS JOB NO. SHEET NO. RD-1Ir137