Loading...
05-1490 (RC)r�- 00 �°'Q BUILDING & SAFETY DEPARTMENT 1504 (760) .777-7012 78-49 C LLE TAMPICO FAX (760) 777-7011 C1TMorcrLA b!•AaQUIN A, CALIFORNIA 92253 INSPECTION REQUESTS (760) 777-7153. FINANCEO - . . BUILDING PERMIT Application Number LO 5=" 000'01490- Date 5/09/05 Property Address . . . . . . 78370 HIGHWAY 111 STE 250 APN: 604-050-048- - - Application description . . . REMODEL - COMMERCIAL Property Zoning . . . . . . . COMMUNITY COMMERCIAL Application valuation . . . . 2500 Owner Contractor --------------------------------- MADISON PTM LA QUINTA --------------------------------- PRIMUS CONTRACTING GROUP, INC 71361 SAN GORGONIO RD 1409 SO: 600 WEST, SUITE D RANCHO MIRAGE, CA 92270 BOUNTIFUL, UT 84010 WCC: STATE FUND WC: 1705181 10/01/05 CSLB: 814726 11/30/06 CCC: B Other struct info CODE EDITION 2001 FIRE SPRINKLERS YES MIXED-USE OCCUPANCY B OCCUPANT LOAD 6.00 ---------------------------------------------------------------------------- 2ND FLOOR SQUARE FOOTAGE 528.00 P.O. Box 1504 • �i . w VOICE (760)'777'-7012 78-495 CALLS TAMPICO FAX (760) 777-7011 LA QUINTA, CALIFORNIA 92253 INSPECTIONS (760) 777-7153 BUILDING & SAFETY DEPARTMENT Application Number: 03-- /' Applicant: Applicant's Mailing Address: Date: Architect or Engineer: Architect or Engineer's Address: Lic. No.. BUILDING PERMIT DECLARATIONS LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professionals Code, and my License is in full force and effect. License Class License No. Date Contractor OWNER -BUILDER DECLARATION I hereby affirm under penally of perjury that I am exempt from the Contractors' State License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractors' State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).): U I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself or through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractors) licensed pursuant to the Contractors' State License Law.). U I am exempt under Sec. , BA P.C. for this reason Date D� Owner 7�'r WORKERS' COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier Policy Number I certify that, in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, if I should become subject to the workers' compensation provisions of Section 3700 of the Labor Code, I shall forthwith comply with thoseprovisions. Date G Applicant WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000), IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Name Lender's Address APPLICANT ACKNOWLEDGEMENT IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the conditions and restrictions set forth on this application. 1. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application, the owner, and the applicant, each agrees to, and shall, defend, indemnify and hold harmless the City of La Quinta, its officers, agents and employeesfor any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building constructio , and herqby autk�orize representatives of this county IQ enter u Don the ab e -mentioned property for inspection purposes. Date 4 / Signature (Applicant or Agent): Application Number . ­05-00001490 ---------------------------------------------------------------------------- Permit . . . . . . BUILDING PERMIT Additional desc . . Permit Fee 54.00 Plan Check Fee 35.10 Issue Date Valuation . . 2500 Expiration Date 11%05/05 Qty Unit Charge Per Extension BASE FEE 45.00 1.00 9.0000 THOU BLDG 2,001-25,000 9.00 -------=-------------------------------------------------------------------- Permit . . . . . . Additional desc Permit Fee Issue Date . . . Expiration Date . . ELECT - ADD/ALT/REM 25.56 11/05/05 Plan Check Fee 6.3'9 Valuation . . . . 0. Qty Unit Charge Per Extension BASE FEE 15.00 528.00 .0200 ELEC GARAGE OR NON-RESIDENTIAL -------------=-----------------------------------------=-------------------- 10.56 Permit . . . . . . MECHANICAL Additional desc Permit Fee . . . . 19.50 Plan Check Fee 4.88 Issue Date Valuation 0 Expiration Date 11/05/05 h Qty Unit Charge Per Extension BASE FEE 15.00 1.00 4.5000 EA MECH VENT INST/ DUCT ALT 4.50 -------------------------------- ------------------------------------------- Special Notes and Comments COMMERCIAL - 528 SQ.FT. INTERIOR TENANT IMPROVEMENT OF SUITE 250. OFFICE FOR MARRA CONSULTING - "WHEELER'S DESERT LETTER" "B" OCCUPANCY, TYPE V -N . CONSTRUCTION, OCCUPANT LOAD=6. 2001 CODES. -----------------7-----------------=---------------------------------------- Other Fees . . . . . . . . . ACCESSIBILITY PLAN REVIEW 3.51 ENERGY REVIEW FEE 3.51 Fee summary Charged Paid Credited ----------------- Due ---------------------------------------- Permit Fee Total 99.06 .00 .00 99.06 Plan Check Total 46.37 .00 .00 46.37 Other Fee Total 7.02 .00 .00 7.02 Grand Total 152.45 .00 .00 152.45 9 P.O. BOX 1504 78-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 Application Number:05-00001490-_ ;. Property Address: 78370 HIGHWAY 111 STE APN: 604-050-048- - Application description: REMODEL - COMMERCIAL Property Zoning: COMMUNITY COMMERCIAL Application valuation: 2500 Applicant: Com' T- &-t 4 4 Q" BUILDING & SAFETY DEPARTMENT BUILDING PERMIT Owner: 250 MADISON PTM LA QUINTA - 71361 SAN GORGONIO RD RANCHO MIRAGE, CA 92270 Architect or Engineer: SEP 29 2005 ____________________________________ ___ LICENSED CONTRACTOR'S DECLARATION CC Q I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (com w Section 7000) of Division 3 of the Business and Professionals Code, and my License is in full force and a ANCEi License Class: B C36 License .: 344538 Date:, Y'--? / O r' Contractor: OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031 .5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: (_ 1 I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). (_) I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). I—) I am exempt under Sec. , B.&P.C. for this reason Date: Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Name: _ Lender's Address: LQPERMIT Contractor: RICHEY CONSTRUCTION, BOB 84550 AVENUE 54 COACHELLA, CA 92236 (760)880-0162 Lic. No.: 344538 VOICE (760) 777-7012 FAX (760) 777-7011 INSPECTIONS (760) 777-7153 Date: 9/29/05 WORKER'S COMPENSATION DECLARATION reby ffirm under penalty of perjury one of the following declarations: I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. _ I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier STATE FUND Policy Number 0030200 _ I certify that, in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, if I should become subject to the workers' compensation provisions of Section C� p 3700 of the Labor Code, I shall forthwit comply with those provisions. Date: / 1_6—rApplicant: WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the conditions and restrictions set forth on this application. 1. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application, the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this county to enter upon the above-mentioned property for i spection pu poses. Date::F Signature (Applicant or Agent): �/ Application Number . . . . . 05-00001490 Permit . . .. BUILDING PERMIT Additional desc . . Permit Fee . . . . 54.00 Plan Check Fee 35.10 Issue Date . . . . 5/26/05 Valuation . . . . 2500 Ei Expiration Date 11/22/05 Qty Unit Charge Per Extension BASE FEE 45.00 1.00 9.0000 THOU BLDG 2,001-25,000 ---------------------------------------------------------------------------- 9.00 Permit . . . ELECT - ADD/ALT/REM Additional desc . Permit Fee . . . . 25.56 Plan Check Fee 6.39 Issue Date 5/26/05 Valuation . . . . 0 Expiration Date.. 11/22/05 Qty Unit Charge Per Extension BASE FEE 15.00 528.00 .0200 ELEC GARAGE OR NON-RESIDENTIAL ----------------------------------------------7----------------------------- 10.56 Permit . . . MECHANICAL Additional desc . Permit Fee . . . . 19.50 Plan Check Fee 4.88 Issue Date . . . . 5/26/05 Valuation 0 Expiration Date 11/22/05 Qty Unit Charge Per Extension BASE FEE 15.00 1.00 4.5000 EA MECH VENT INST/ DUCT ALT. 4.50 ---------------------------------------------------------------------------- Special Notes and Comments COMMERCIAL - 528 SQ.FT. INTERIOR TENANT IMPROVEMENT OF SUITE 250. OFFICE FOR MARRA CONSULTING - "WHEELER'S DESERT LETTER" "B" OCCUPANCY, TYPE V -N CONSTRUCTION, OCCUPANT LOAD=6. 2001 CODES.9-29-05 CHANGE OF.CONTRACTOR. ---------------------------------------------------------------------------- Other Fees . . . . . . . . . ACCESSIBILITY PLAN REVIEW 3.51 CHANGE OF CONTRACTOR 4.50 ENERGY REVIEW FEE 3.51 Fee summary Charged Paid Credited Due --------------------------------------------------------- Permit Fee Total 99.06 99.06 .00 .00 0 t LQPERMTT • �. - - Application Number . . . . 05-00001490 Plan Check Total 46.37 46.37 .00 .00 Other Fee Total 11.52 7.02 .00 4.50 Grand Total 156.95 152.45 .00 4.50 i r LQPERMIT P.O. BOX 150"4 78-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 To: Greg Butler, Building & Safety Manager From: Doug Evans, Planning Director BUILDING & SAFETY DEPARTMENT (760) 777-7012 FAX (760) 777-7011 To CDD: 04/22/05 Due date: 05/06/05 Status: Building Plans Approval (This is an approval to issue a Building Permit) The Community Development Department has reviewed the Building Plans for the following project: Description: Tenant Improvement - Wheelors Desert Letter Address or general location: 78-370 HIGHWAY 111 Suite 250 Applicant Contact: Ed Alderson 771-1755 • 1 The Comm y Development Department finds that: #µ ."..these.Building Plans do not require Community Development Department approval. ❑ " ...these Building Plans are approved by the Community Development,; i1 Department. ❑ ...these Building Plans require corrections. Please forward a copy of -the attached corrections to the applicant. When the corrections are made please return them to the Community Development Department for review. lanning Dire Date RIVERSIDE COUNTY FIRE DEPARTMENT: Highway Indio, Fax - DEPARTMENT Craig E. Anthony November 8, 2005 Fire Chief Proudly serving the City of La Quinta unincorporated Building Department areas of Riverside County and the Cities of: Re: Fire and Life Safety Clearance Banning LAQ-05-TI-036 e.4 78-370 Hwy 111, Ste. 250 Beaumont 4. The Riverside County Fire Department is granting a fire and life safety clearance for the group Cahmesa B occupancy known as Wheeler Publishing. Canyon Lake 4 - Coachella Respectfully, Desert Hot Springs Tracy Hobday Indian wells Chief Fire Department Planner Indio Lake Elsinore .;. B La Quints y Walter Grandes Moreno Valley Fire Safety Specialist Palm Desert .y Perris 4. Rancho Mirage 4. San Jacinto .;. Temecula Board of Supervisors Bob Buster, District 1 John Tavaglione, District 2 Jeff Stone, District 3 Roy Wilson, District 4 Marion Ashley, District 5 HAPEAM Oatata QWrda1PR0JECTMT111Ag05-T1-= Fhml.doc EMERGENCY SERVICES DIVISION • PLANNING SECTION • INDIO OFFICE 82-675 Highway 111, 2nd R., Indio, CA 92201 • (760) 863-8886 • Fax (760) 863-7072 Craig E. Anthony Fire Chief Proudly serving the unincorporated areas of Riverside County and the Cities of: Banning 4: Beaumont 4. Calimesa 4. Canyon Lake Coachella Desert Hot Springs e. - Indian Wells 4. Indio Lake Elsinore 4. La Quinta Moreno Valley Palm Desert Penis Rancho Mirage `• San Jacinto 0 Temecula Board of Supervisors Bob Buster, District 1 John Tavaglione, District 2 Jeff Stone, District 3 Roy Wilson, District 4 Marion Ashley, District 5 RIVERSIDE COUNTY FIRE DEPARTMENT April 27, 2005 Prest, Vuksic, Architects, Inc. 44-530 San Pablo Ave, Ste. 200 Palm Desert, CA 92260 Re: Non -Structural Building Plan Review LAQ-05-TI-036 /-Marra Consulting - Plaza @ Point Happy — Suite 250 Fire Department personnel have reviewed and approved the plans you submitted for the above referenced project. Please be advised the following conditions apply as a part of the conditions for the issuance of a building permit. 1) Fire sprinkler system plans for the tenant improvement area must be submitted to the Fire Department for review, along with a plan/inspection fee. The approved plans, with Fire Department Job card must be at the job site for all inspections. 2) Provide keys to the tenant space for inclusion in the main building Knox Box. Key(s) shall have a durable and legible tag affixed for identification of the correlating tenant space. 3) Install portable fire extinguishers per Title 19, but not less than 2A1 OBC in rating. Contact certified extinguisher company for proper placement of equipment. 4) Approved building address shall be placed in such a position as to be plainly visible and legible from the street and rear access if applicable. In multi -tenant buildings, businesses shall post the business name and suite number on back doors as well as the front. Suite numbers or letters must be a minimum of 6" in height. All addressing must be legible and of a contrasting color with the background. Please contact the Fire Department Planning & Engineering staff for final inspection prior to occupancy. Requests for inspections are to be made at least 72 hours in advance and may be arranged by calling (760) 863-8886. All questions regarding the meaning of these conditions should be referred to the Fire Department Planning & Engineering staff at (760) 863-8886. Sincerely, FRANK KAWASAKI Chief Fire Department Planner By Walter Brandes Fire Safety Specialist Cc: City of La Quinta - Building Dept. KVEZAP Daft" 0ukhV4KW MTTUAo-0LaF1=.d•e EMERGENCY SERVICES DIVISION • PLANNING SECTION • INDIO OFFICE 82-675 Highway 111, 2"d FI., Indio, CA 92201 • (760) 863-8886 • Fax (760) 863-7072 Certificate of Occu ancy P T4&f ot QUA& G� OFT19� Building Y p & Safety Department This Certificate is issued pursuant to the requirements of Section 109 of the California Building Code, certifying that, at the time of issuance, this structure was in compliance with the provisions of the Building Code and the various ordinances of the City regulating building construction and/or use. BUILDING ADDRESS: 78-370 Highway 111 Suite 250 Use classification: Commercial "Office" TI Building Permit'No.: 05-1490 Occupancy Group: B Type of Construction: VN Sprinkled Land Use Zone: CR Owner of Building: Madison PTM La Quinta Address: 71361 San Gorgonio Rd City, ST, ZIP: Rancho Mirage, CA 92270 - �+&14 By: Daniel P. Crawford Jr. Date: 11115/05 - Building Official - POST IN A CONSPICUOUS PLACE Apr. 22. 2005 8: 58AM No. 4224 P. 2 CERTIFICATE OF GOMPLIANGE Part I of 3 LT6-I PRO -ECT NAME 5UITE 250; BUILDING B DATE 04/08/05 PROJECT ADDRESS HIGHWAY III 4 WA5HIN6TON Permit PRINCIPAL DE516NER - LIGHTINGBuilding ROBERT A. 5TEPHEN5 160 321-7841 ❑ NONR!"51DENTiAL p HIGH RISE RESIDENTIAL ❑ HOTEUMOTEL GUE5T ROOM DOCUh�NTA1TON AUTHORCaked 51'STEM ELECTRIC GO. INC. 160 321-1841 by/bate i�AIFZD A I I AICnOI A A rl ry l ��ZO IGHTIN6 ANCE Wortorwt Aggg Use DATE OF PLAN$ ILDING CONDITIONED FLOOR AREA IMATE ZONE 528 sqFt. 15 BUILDIN6 TYPE ❑ NONR!"51DENTiAL p HIGH RISE RESIDENTIAL ❑ HOTEUMOTEL GUE5T ROOM MME OF CaN9TRIIGTiON NEW CONSTRUCTION p ADDITION ❑ ALTERATION ❑ EXISTING . ADDITION ��ZO IGHTIN6 ANCE ❑ COMPLETE BUILDING p AREA CATEGORY ❑ TAILORED ❑ PEWORMANC.E 4TATCMj--MT nC 1"/lAAID1 1AA1/G -II uu ILnI VI WI-Irwrlrun- This Certificate of Compliance lists the bullding Features and performance specifications needed to comply with Title 24, Farts I and b of the Callfornla Gods of Regulations. This certificate applies only to building fighting requirements. The documentotlon preparer hereby certifies that the documentation is accurate and complete. ROBERT A. 5TEPHEN5 I F-01 The Principal Lighting Designer hereby certlrle5 that the proposed building design represented in this set of construction documents Is comIstent with°the other compliance forms and Worksheets, mith the specifications, and with any other calculations submitted with this permlt application. The proposed building has been designed to meet the lighting requirements contained In Sections 110,114,130 through 132, and 146 or 149 of Title 24, Part b. Please check one; ❑ I hereby affirm that I an eligible under the provisions of DM5lon 3 of the Mtness and Professions Code to sign this document as the person resporsttile For Its prepparation; and that i an licensed In the State of C41lFornin 05 a civil engineer or electrical engineer, or I an a Ilcersed archltect. . ®I affirm that I am el!qIble under the provisions of Division 3 of the Buslnes5 and Professions Gode by Section 55312 or 61313 to sign this d"ocawt as the person responsible For Its preparation; and that I am a licensed contractor performing this work. ❑ i affirm that I am ellgble under the exemption to Division 3 of the Business and Professions Code to sign this document because It pertains to a structure or type of work described as exempt pursuant to Business and Profes5lon5 Code Sections 5531,553b and 6131.1. 610203019 Indicate location on plans of Note Block For Mandatory Measures ISHEET E1.1 ror aerauea 1n5u'ucu0n5 on the use of this and all Energy EFficlency Standards compliance Forms, please refer to the bwesldentlal Manual published the California Energy -Commission. LTG -I: Required on plans For asubmittals. Part 2 and 3 may be Incorporated In schedules on plans. LTG -2: Required on all submittals. LT6-3; Optional. Use only IF lighting control credits are taken. LTO -4: Optional. Use only IF Tailored method is used. LT6-5: OPtiorial. Use only If Tailored method 15 used. Enerquft 3.1 . Sq kilwgA6Pt User NuMber - .bb Naribery - I IRMW of 5 C Apr. 22. 2005 8: 58AM No. 4224 P. 3 LIGHTING GOMPLIANGE SUMMARY Part 2 of 3 LT6-I I°RO.IECT NAME SUITE 250, BUILDI N6 B SATE 0/08/05 INSTALLED LIGHTING SCHEDULE Lighting Schedule on Pkm Shows Extehor LWh.g Meets ❑ Effk-aq and Control RegWement of 13o(c) ❑ Control Requirements of 1310) Subtotal From this Page 5qq Total C Portable Lighting (From LTC -0 Less Control Credit Watts (From LT(; -3) F— MANDATORY AUTOMATIC CONTROL5 corJTJ Loc fnON CONTROL CONTROL TP riorE ro onIDENTIFICATION (Auto Tkw Switch, Exterior, etch SPADE CONTROLLED FIELD COMM. RM "LDP" AT5 INTERIOR CONTROL5 FOR CREDIT DM ) IDENnGOFiGATiON Enwqfto 31 99Ener t 055 N rriben - Joy NArben . P :2 OF 3 04 ROUND REG 00ML16-H—T • • OEM - ' �m • • ��� / I _ ■■ ■--_ _ .m ■--_ 100 0 Lighting Schedule on Pkm Shows Extehor LWh.g Meets ❑ Effk-aq and Control RegWement of 13o(c) ❑ Control Requirements of 1310) Subtotal From this Page 5qq Total C Portable Lighting (From LTC -0 Less Control Credit Watts (From LT(; -3) F— MANDATORY AUTOMATIC CONTROL5 corJTJ Loc fnON CONTROL CONTROL TP riorE ro onIDENTIFICATION (Auto Tkw Switch, Exterior, etch SPADE CONTROLLED FIELD COMM. RM "LDP" AT5 INTERIOR CONTROL5 FOR CREDIT DM ) IDENnGOFiGATiON Enwqfto 31 99Ener t 055 N rriben - Joy NArben . P :2 OF 3 Ct Ap r. 22. 2005 ' 8: 58AM No. 4224 P. 4 LIGHTING GOMPLIANGE 5UMMAR'' Part 3 of 3 LT6-I I rm"c"' '""' SUITE 250, BUILDIN6 B IPATE 04/08/05 TABLE IB - PORTABLE L16HTIN6 5HOWN ON PLAN5 FOR OFFICE AREA5 >250 SQUARE FEET FAI© o a a F a ROOH ILUMK TASK I OF . TOTAL. TOTAL MW io FORTABL.E Ll6nP46 s OF WATTS PER AREA TA5K A1 -A (SF) WATTS t VILUINO SUMMAKT - PORTABLE LIGHTING BUILDING SUMMARY ( ) (SROM TA�6LE5 IA+16+1G) TOTAL WATT5 (FROM TABLES IA -IB) BUILDING TOTAL 52b b34 TOTAL. TABLE K, - PLAN5 SHOW PORTABLE LIGHTING 15 NOT REQUIRED FOR OFFICE AREAS > 250 5QUARE FEET OR ZONE Ip A)R1 A ( h needs Dasto provide detalled documentation that the IlotN level provided bg the overhead Ilcitlng meets the needs of the space. The details include luminaire tFas, GU, and mounthq locatlons relative to work areas. TOTAL 1 0 t VILUINO SUMMAKT - PORTABLE LIGHTING BUILDING SUMMARY ( ) (SROM TA�6LE5 IA+16+1G) TOTAL WATT5 (FROM TABLES IA -IB) BUILDING TOTAL 52b b34 r --&. l 3.1 EN Ener User Nmber: - Job N,mbW! - P !3 of 9 c` Apr. 22. 2005 '8: 58AM No. 4224 P. 5 L16HTIN6 COMPLIANCE SUMMARY LT6 �l�T NAME 5UITE 250, BUILDIN6 B 04/08/05 ACTUAL LIGHTING POWER LUMINAIRE DESGRIMON MAIDW OF UHIMAIRE5 WATT5 PLR LUMINAIRE (Inklvd[nQI EC DffAULT Total Watts Y N' A 2'X2' REG. FLUOR. 4 62 ©❑ ©❑ ®❑ El E] ❑❑ ❑❑ ❑❑ ❑❑ 246 B ROUND REG DOWNLI6HT 1 13 91 G GABLE L16HT 13 20 260 WATT5 PER 5F AREA (51F) ALLOWED WATT5 PA6F TOTAL D BUILDING TOTAL D D 5 TOTAL ALLOWED WATT5 (From LT6-4 or From ter nul.J Subtotal From Ws Page 5qq Bulldog Total Portable 44" (From LT6-V Less Control credit Watts (From LT6-3) A4)usted Actual Ptatts SK ALLOWED LIGHTING POWER Choose One Meffinti) COMPLETE BUILDING METHOD BUILDING CATEGORY (From Table I-tV WATT5 PER SP GOMf'LPiE q�Op� WATTS OFFIGE I.2 528 634 AREA CATEC-OW METHOD AREA CATEGORY (From Tdblo I -N WATT5 PER 5F AREA (51F) ALLOWED WATT5 PA6F TOTAL D BUILDING TOTAL D D 5 TOTAL ALLOWED WATT5 (From LT6-4 or From ter nul.J Ener o Ft User mfty Job NHLW, P SO/QO/-vo 9 gviiine 'oGz ainS zM I . It WW-91� 5i.,c (nG iw ,,WId4NVH 9NI1H911 9 'd tizzy ON Wd85: q Soot 'ZZ 'JAV ti 'ssal Jo sdW 0,- WP ZWP IM vilroV U0 PAMims. NoIDJDd05 aq IIDys bunLAI fiDlciqa -&4,4l fil2Idsla (a)I>rl -lewd IDOIJIoal9 M 4 fiDloJ 6ulpu0ds9,,um D Pw JOOu GtA uo I0JIU07 IM CqNd 1VMI aJlp n 4IIM PsIloJlum oJD NpllNA M OP154 loved Imlival9 Stn wail ponm s9j"j ovpm WIJ81q °57461"1 jowng Jo io-Auog un a s�nld uo P9Pr N sl Joofi 941 to N I JJ� 6W� sew uo.r9 � 6WVW Jo WhOtQ 'I01.1Ua�DfPD" UO 6gpllnq D fiA POPOW fil5nonn ILW Ox SMOPWM 941 Xm-)N P04611�� v ®q I 14 ifiop 40 9sn S'd�J 9ngV94i9 Jo'IMIM5 9Ioxcles n FI P9110JILM r'" Ilft 4"G w `AI " jo %os envy IIS 09-V Of! a 10IFnP Jo 95n VAIMJ19 An JoJ MOIID IMM pW I"d a mbs 05E W11 J9ID9J6 ®JD 1041 6I4611FD15 PW 540pgM tMM SwooJ IIV `IagU07 po y lAlFoa (.2rEl w0ou 941 LMM 6WI4611 10 U01rXWJ WJO410 J01614�9IM5 I9n9I-lq u}IM P9110JIUO: 5`dzl aI uOW Pool k4ii Jo 1ooJ o-wbs Jad SIIvM 90 W41 9.Ow Pun 1994 9JDnbs 001 W41 J8109J6 span Pw 6UJOOJ IIV ;qWa l IDWIPul roJ m1vnpe21 UUOJILn (WIEI 'sIIDM 4193'- JCoIJ IMM C9J0 4W9 J01 921A8P J0006 f=dnYio JD "Ims gpxd9s D 7 Lglm PaInbo 9 buIPllril s14I W 00-D PSD w00J 4"9 ISI0409 DONA000d lvwq I (D)Iel .s,W 4AbaJ 6444 u19Pun1 W" Id`MXV SJD PUD 5150116x1 fnu9nb9JJ414 01WA-Y 19 tam peul"dS oJo 40.0VII 7ua759,1on14 djq tv q IID w ., tgl uoMges spxptjm fiq P046pJ NOW yIWIID'q &I om:l 471M pg -gm uWwI 9Jn SOAK, 1U9059Jorgj duel go -q Pw 9W Ily `50-MxI,A 1u9vseJOn dural 99J41 pw au0 JoJ Nim incl zo P9IJIIJaJ 9411046 6o-XI1 MPIsw IIV -rte-m.qo ®4I W Pg9I Pm Po►JII,," ax mroid S'd�J JoJ IaIJI"A, som"I au9-,soxnlJ IN poll"j" s9AUWuq Iw IWIIoA 7N� Wl FA PvM4P W MINN PW P®IdllAo eq IIvW aumAnb9 eaauallo Ilv'peIJlw S" . 9Jo POIJI79ds 5011n91P 10ilut" 9n uqw Iry minjog SWNea laqL'YJ onDUKInll (L&I IM LLJ _19919JDnbs o0d6 P999x9 01 IOU 51 q "Ao 5'dZl Jo Dan 941 .5411 141 Jo I461s u147IIMS OnAWno Gl4SS97W ynnuvw D 1QM P9pinoid sl ar9lsf� JJo-InW NPllrlq 9IIDua1w Ma=JJo-In4S 6ulori 6uppq Joy 9 l"V Zoo 0 ft AIAl GLA JJo Null NlmwmInr) jo 9192cit" 971A®P-VtnO�Jo VgIms ewll')IIPW0Iry J0W*S fnw&rm w oq'fivw Pw b1► uoII�S V Q IO 5au9w9 9iuroJ 941 198U% IIS IOJ1U07. DIIDuOIID 6141 .6MLAI eta jj0 vW 01 Iain JIOUJOIn0 19gVX dos D WM paddlnba eq 11RP SUVA Wil J01*4 IID ',,volt hMAG Jo -j I(P)Iel N auaula��o�u� .4au6isa4 NOL LJI 0530 SO/QO/-vo 9 gviiine 'oGz ainS zM I . It WW-91� 5i.,c (nG iw ,,WId4NVH 9NI1H911 9 'd tizzy ON Wd85: q Soot 'ZZ 'JAV 4r-22. 2005 8: 58AM No. 4224 P. 2 GERTIF16ATE OF GOMPLIANGE Part I of 3 LT6-1 PRO.IFCT NAME SUITE 250, BUILDIN6 B DATE 04/08/05 PROJECT ADDRESS CLIMATE ZONE HIGHWAY III t WA5HIN6TON Buildng Permit # PRINCIPAL DE516NBZ - LI6HTIN6 15 ROBERT A. 5TEPHEN5 160 321-1541 cmcked by/bate DOGII�NTATION AUTHOR 5Y5TEM ELEGTRIG GO. INC. T0. 160 321-1841 i rum.. n..--..--... METHOD OF LIGHTING W,,umnt Aqmq Usg DATE OF PLAN$ ILDI% CONDITIONED FLOOR AREA The documentation preporer hereby certifies that the documentation Is accurate and complete. CLIMATE ZONE 528 sqft, ROBERT A. 5TEPHENS 15 BUILDIN6 TYPE NONRIw51DENTIAL [] HIGH RISE RESIDENTIAL E] HOTamoTEL GUEST Room PHME OF 60N6T@1GTiON NEM CONSTRUCTION ADDITION ❑ ALTERATION E] EXI5TING r ADDITION METHOD OF LIGHTING [] COMPLETE INJILDING AREA CATEGORY 0 TAILORED Ej PERFORMANCE COMPLIANCE b1313 to sign this document as the person responsible For its and that I am a preparation; licensed contractor perF"Ing this work. u u iLn r Vr WI q LI �I�VL This Certificate of Compliance lists the building Features and performance specifications needed to comply with Title 24, Ports I and b of the GaIlFornia Gods of Regulations. This certificate applies only to building lighting requirements. The documentation preporer hereby certifies that the documentation Is accurate and complete. DOCUMIENTATION AUTHORDATE ROBERT A. 5TEPHENS r6,,ATu,,,-- 04/08/0 The Principal Lighting Designer hereby certifies that the proposed building design represented In this set of construction documents Is consistent Wlth°the other compliance Forms and Workshe l:s, with the specifications, and with any other calculations submitted with this permit application. The proposed bullcIN has been designed to meet the lighting ' requirements contained in 5ectlons 110, IIB, 130 through 132, and 146 or 149 of Title 24, Part b. Please check one: r] I hereby aFFirm that I an eligible under the provisions of Division 3 of the Business and Professions Gode to sign this document as theperson responsible For Its preparation; and that I am licensed In the 5tate of California as a civil engineer or electrical engineer, or I an a licensed architect. ® 1 affirm that I am el ible under the provisions of Division 3 of the Business and Professions Code by Section 55312 or b1313 to sign this document as the person responsible For its and that I am a preparation; licensed contractor perF"Ing this work. I affirm that I am ellgable under the exemption to Division 3 of the Business, and Professions Code to 5191 this document because It pertains Eo a structure or type of described work as exempt pursuant to Business and Professlon5 Code 5ectlons 5531, 5538 and 6131.1. PRINCIPAL LIGHTING DESIGNER - NATE 51OMTVREr04/0b/05 LIG. # ROBERT A. 5TEPHEN5 610203019 LIGHTING MANDATORY MEASURES Indicate location on plana of Note Block For Mandatory Measures 5HEET ELI For detailed Instruetlons on the use of this and all Energy EFFIclency Standards compllonce Forms, plea Nonresidential Manual published the California Energy Gommisslon. LTG -I: Required on plans For off submittals. Part 2 and 3 may be, incorporated In schedules on plans. LTG -2: Required on all submittals. LT6-3: Optional. Use only IF lighting control credits are taken. LT6-4: Optional. Use only iF Tailored method Is used. LT6-5: Optional. Use onlu IF Tailored method Is used. BrerquPro 5,1 By Erwq I't User Nurber - .Job Nmberr - of 5 I Apr. 22. 2005 8: 58AM No. 4224 P. 3 L IGHTIN6 COMPLIANCE 5UMMARY Part 2 of 3 LT6-1 I PROJECT NKIE SUITE 250, BUIL L)IN6 B DATE INSTALLED LI6HTIN6 56HEMLE I ..nom I .STM Lighting Schedule on Plans 9ior+9 Exterior LlghtUlg Meets ❑ Effl"q and Control Requirement of 130(c) ❑ Control Requirmionts of 1310) Subtotal From this Page Total Portable Llghting (From LTG -1) Less Control Credit Watts (From LT6-3) Sqq 5qq MANDATORY AUTOMATIC, GONTROL5 GORp� LOCATION CONTROL CONTROL TYPE NOTE TO (Room 10 IDENTIFICATION (Auto Three 5wltch. Exterior, eW SPACE CONTROLLED FIF1D COMM. RM 16P" AT5 I TERIOR GONTROL5 FOR CREDIT LOCATION II IDENTIFICATION r3wqfto 31 gg Ener t User NxNaer, - JOb Nxnbwen - P !2 Of 3 :4 1 U 1 [#Jl IBM[- - ©® �- ■mm - i ROUND REC, DO ��Mmmmlq �� ■m®= ■■r�■■• ■m mmm ,. r ■■ ■MNIMISM ■■ ■■ ■ ■■M EN ■■■■■SME ■■ ■ IM ISM ■■ ■IEMEN MINIMEM MEN ME IME ■■■ ■��� IME ■■ ■ �� ■■ ■��� Lighting Schedule on Plans 9ior+9 Exterior LlghtUlg Meets ❑ Effl"q and Control Requirement of 130(c) ❑ Control Requirmionts of 1310) Subtotal From this Page Total Portable Llghting (From LTG -1) Less Control Credit Watts (From LT6-3) Sqq 5qq MANDATORY AUTOMATIC, GONTROL5 GORp� LOCATION CONTROL CONTROL TYPE NOTE TO (Room 10 IDENTIFICATION (Auto Three 5wltch. Exterior, eW SPACE CONTROLLED FIF1D COMM. RM 16P" AT5 I TERIOR GONTROL5 FOR CREDIT LOCATION II IDENTIFICATION r3wqfto 31 gg Ener t User NxNaer, - JOb Nxnbwen - P !2 Of 3 Jf Ap r. 22. - 2005 8: 58AM No. 4224 P. 4 L16HTIN6 GOMPLIANGE 5UMMARY Part 3 of 3 LT6-I PRO.EFGT OVE 51JITE 250, BUILDING B DATE 04/08/05 TABLE IA - PORTABLE LIGHTING NOT 5HOHN ON PLAN5 FOR OFFICE AREAS >250 SQUARE FEET TABLE IB - PORTABLE LIGHTING SHOHN ON PLANS FOR OFFICE AREAS >250 SQUARE FEET FAI © o 0 o a a U"K TASK V OF TOTAL, TOTAL RDOM I PORTABLE U61 -MM& 4 OF MTr5 PW AREA TASK AREA (T) WATTS M MW In n ._tea.— Mr care inch n - — BUILDING 50MMARY - PORTABLE LIGHTING ( ) BUILDING SUMMARY (FROM TA�>3L IA+16+tG) (FRO A�BL5 A+IBJ BUILDING TOTAL 6 &Wqfto 3.1 E4 &ffq450ft User Knber: - Job N,mbw! - Paae:3 aF 3 TOTAL TABLE IG - PLAN5 5HON PORTABLE LIGHTING 15 NOT REQUIRED FOR OFFICE AREAS > 250 5QUARE FEET ORONs E ID TOTAE A)RFA (( D85ITer needs to provide detailed docurrentotlon that the IlghtN level provided by the overhead Lighting meets the needs of the space, The details Include luminalre hVes, a, and mauntN locatlons relative to work areas. TOTAL 1 O . BUILDING 50MMARY - PORTABLE LIGHTING ( ) BUILDING SUMMARY (FROM TA�>3L IA+16+tG) (FRO A�BL5 A+IBJ BUILDING TOTAL 6 &Wqfto 3.1 E4 &ffq450ft User Knber: - Job N,mbw! - Paae:3 aF 3 Apr, 22. 2005 8 ; 58AM No. 4224 P. 5 L16HTIN6 6OMPLIANGE 5UMMARY LT6-2 PROJECT NAME 5UITE 250, BUILDIN6 B DATE 04/08/05 AGTl1AL LIGHTING POKER WMllNAIRE t(AI DESGRIFMON NJMBER OF UHIMAIRE5 WATT5 PER LUMINAIRE (InQlvdhigI CEC DEFAJLT Total Watts Y N' ©❑ ®❑ ®❑ E] E] D❑ ❑❑ ❑❑ A 2'X2' REG. FLUOR. 4 62 248 B ROUND REG D0HNLI6HT l 13 91 G GABLE L16HT 13 20 260 WATT5 PER 5F AREA (51F) ALLOYED WATT5 PA6E TOTAL ` BUILDING TOTAL D AREA 5 TOTAL ALLOPED HATT5 (From LT6-4 or From ter nmJ Subtotal From thl5 Page 5qq Bulldhq Total Portable LlghWq (From LTErU Less Control Credlt Hatt5 (From LT6-3) Adjusted Actual Ybtts Sqq Al I nV4rD 11(4MINA Pf)WPP /1'hnmao 1)„o Moi6~41 COMPLETE BUILDING METHOD BUILDING CATE60RY (From Table I -MU WATT5 PER SF WAT15 OFFIGF 1.2 528 634 AREA CATEGORY METHOD AREA GATEGORY (From Table I -N WATT5 PER 5F AREA (51F) ALLOYED WATT5 PA6E TOTAL ` BUILDING TOTAL D AREA 5 TOTAL ALLOPED HATT5 (From LT6-4 or From ter nmJ tiler o ft User Reber ,bb mntw. P a Apr. 22. 2005 8: 58AM No. 4224 P. 6 LIGHTING MANDATORY MEA5URE5 LTG -MM PR0'rr WE SUITE 250, BUILDIN6 B I DATE 04/08/05 DE5GRIPTION I Designer I Enforcement © 131(d)I For every floor, all Interior Ilghting systems shall be equipped with a separate adanotic control to shut off the lighting. This automatic control shall meet the requbements of RA5 Section IN and may.be on ocapancy sensor, automatic time swltch, or other device usable of automatically shutting off the lighting. 0 131(d)2 Override For Building Lich 5hwt-oFf: The automatic building shut-off sgstem is provided with a marual, accessible override SNltch In sight of the lights. The area of RA5 override is not to exceed 5,000 square Feet. ® Ilq(V Automatic Conb,ol Device, C®rtlW, All automatic control devices speclfled ore certified, all alternate equipment shall be cwtlfied aurid Installed as directed by the RA5 manufacturer. Fluorescent Ballot aid Luminaires Certified: All Fluorescent Fixtures specified For the project ore certlFled and Ilsted in the Directory. All installed Fixtures stall be ceAlMed. RA5 132 Tandem Wiring For One and Three Lamp Fluorescent Fixtures: All one and three lamp Fluorescent Ft+bAvr, are tandem wired with two larp ballasts where raqu(red by 9tarbards 5e6tlon 132; or all three lamp Fluorescent Fixtures are specified with RA5 electronic high -frequency ballasts and ars exempt From tandem wlrtng requirememt5. 0 131(a) MMdual Room/Area Co itrob, Each room acid area In this Nil" is equipped with RAS separate switch or ouupa q sensor device for each ores with Fbor4o-coilmy walls. JZ 131(b) LhlForm Reduction for Indlvldual Rooms: All rooms and areas greater than loo square feet and more than Ob watts per square Foot of lighting load shall be RAS controlled with bl-level switching For uniform reduction of lighting withln the room, ❑( 131(c) Daylight Area Control: All rooms with wlndom aid 9411ghts that are greater than 250 square Feet amd that allow For the effective use of daylight in the "a shall have 50% of the " in each dayllt area controlled by a separate switch; or the orfective RA5 use at doyllght carrot be accomplished because the Nlndows are conte n,ously shaded by a bullding on tho adjocent• lot. Dlagraum of shading during different tines of the year Is included on plans. 0 131(F) Control of Exterior Ughts: Exterior mounted Fbchre5 served from the electrical panel Inside the building are controlled with o directional photo cell control on the roof and a corresponding re4 In the electrical panel. ❑ 131(e) Display 1-11itmg. Dbplq I19fiting shall be separately switched an dreults that ane 20 a" or less.