14-0774 (RC)T i
78-495 CALLE TAMPICO
4 a(� VOICE (760) 777-7125
LA QUINTA, CALIFORNIA 92253r FAX (760) 777-7011
COMMUNITY DEVELOPMENT DEPARTMENT INSPECTIONS (760) 777-7153
BUILDING PERMIT
Date: 7/21/2014
Application Number: RC -14-774 Owner:
Property Address: 78411 HIGHWAY 111 HARSCH INV REALTY
APN: 604050059 1121 SALMON ST 4TH FL
Application Description: DELETION OF 2 DECORATIVE BALCONIES PORTLAND, OR 92253
Property Zoning:
Application Valuation:
Applicant:
ROBERT RICCIARDI
41325 YUCCA LN
BERMUDA DUNES, CA 92203
LICENSED CONTRACTOR'S DECLARATION
I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter
9 (commencing with Section 7000) of Division 3 of the Business and Professions Code,
and my License is in full force and effect.
License Class: B License No.: 327652
_ c.
Date: � �ntractor Q
OWNER -BUILDER DECLARATIONf J
I hereby affirm under penalty of perjury that I am exempt from the Contractor's State
License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any
city or county that requires a permit to construct, alter, improve, demolish, or repair
any structure, prior to its issuance, also requires the applicant for the permit to file a
signed statement that he or she is licensed pursuant to the provisions of the
Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3
of the Business and Professions Code) or that he or she is exempt therefrom and the
basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a
permit subjects the applicant to a civil penalty of not more than five hundred dollars
($500).:
(_) I, as owner of the property, or my employees with wages as their sole
compensation, will do the work, and the structure is not intended or offered for sale.
(Sec. 7044, Business and Professions Code: The Contractors' State License Law does not
apply to an owner of property who builds or improves thereon, and who does the work
himself or herself through his or her own employees, provided that the improvements
are not intended or offered for sale. If, however, the building or improvement is sold
within one year of completion, the owner -builder will have the burden of proving that
he or she did not build or improve for the purpose of sale.).
(_) I, as owner of the property, am exclusively contracting with licensed contractors
to construct the project. (Sec. 7044, Business and Professions Code: The Contractors'
State License Law does not apply to an owner of property who builds or improves
thereon, and who contracts for the projects with a contractor(s) licensed pursuant to
the Contractors' State License Law.).
(_) I am exempt under Sec. B.&P.C. for this reason
Date:
Owner:
CONSTRUCTION LENDING AGENCY
I hereby affirm under penalty of perjury that there is a construction lending agency for
the performance of the work for which this permit is issued (Sec. 3097, Civ. C.).
Lender's
Lender's
Contractor: U �" " Il
JEFFREY C WATTENBA U
79575 MANDEVILLE R D JUL 21 2 114
BERMUDA DUNES, CA 22 3
CITY OF LA QUINTA
(760)578-7375 COMMUNITY DEVELOPMENT DEPARTMENT
Llc. No.: 327652
WORKER'S COMPENSATION DECLARATION
I hereby affirm under penalty of perjury one of the following declarations:
I have and will maintain a certificate of consent to self -insure for workers'
compensation, as provided for by Section 3700 of the Labor Code, for the performance
of the wor r which this permit is issued.
Se&I have and will maintain workers' compensation insurance, as required by
ion00 of the Labor Code, for the performance of the work for which this permit
is issued. My workers' compensation insurance carrier and policy number are:
Carrier: _ Policy Number: _
I certify that in the performance of the work for which this permit is issued, I
shall not employ any person in any manner so as to become subject to the workers'
compensation laws of California, and agree that, if I should become subject to the
workers' compensation provisions of Section 3700 of the Labor Code, I shall forthwith
comply with those provisions.
Date:(Applicant:
ia 1/4 641
WARNING: FAILURE TO SECURE WORKERS' COMdLlON COVERAGE IS UNLAWFUL,
AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO
ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF
COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE,
INTEREST, AND ATTORNEY'S FEES.
APPLICANT ACKNOWLEDGEMENT
IMPORTANT: Application is hereby made to the Building Official for a permit subject to
the conditions and restrictions set forth on this application.
1. Each person upon whose behalf this application is made, each person at whose
request and for whose benefit work is performed under or pursuant to any permit
issued as a result of this application , the owner, and the applicant, each agrees to, and
shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents, and
employees for any act or omission related to the work being performed under or
following issuance of this permit.
2. Any permit issued as a result of this application becomes null and void if work is
not commenced within 180 days from date of issuance of such permit, or cessation of
work for 180 days will subject permit to cancellation.
I certify that I have read this application and state that the above information is correct.
I agree to comply with all city and county ordinances and state laws relating to building
construction, and hereby authorize representatives of this city to enter upon the above
mentioned property for inspection purposes.
Date: Z L `Signature (Applicant or Agent):
r
ez;� f_
'4%
Bin #
City of La Quinta
-Building &r Safety Division
P.O. ' Box 1504, 78-495 Calle Tampico
La Quinta, CA 92253 - (760) 7.77-1012
Building Permit Application and Tracking- Sheet
Permit #
Project Address:
Owner's Name:
up
A.P.Number:CoD�%��
Add
Address: 4 L
L I egal Description: 0 L'�
j City, ST, Zip: k-'^1
Contractor:
:S_LTc
ielephone: 0 0
------------ -- ---- ---
7 ->Z<-:3-'`>Z
. ..... ..
Address: -
ProjectDescription:
City, ST, Zip--z2e
dU 12
ol e i e -k 6 _*_4
Telephone:
X-1
Z-4 1,4
State Lic. #
City Lic. #...
Ce Aj Ife/"
Arch., Engr., Designer:2
p ')s,
Address: 4A 0 0 Fy -_4
City., ST, Zip:. 1 A- CA 9 2 2
Telephone:0 (p
State Lic. #:
6,L) P IA 1 4 j d
0
Construction Type: Occupancy:
Pi oject type (circle one): New Add'n Alter Repair Demo
Name of Contact Person:F
4 �k— PL, C, k e;' r—d .1
Sq. Ft:
T—Stories:
Units:
Telephone *.of Contact Person: 0 0 -3 L_
Estimated Value of Project: 0c) 0
APPLICANT: DO NOT WRITE BELOW THIS LINE
N
Submittal
Req'd
Rcc'd
TRACKING
PERMIT FEES
Plan Sets
Plan Check submitted
Item
Amount
Structural Calcs.
Reviewed, ready for corrections
Plan Check Deposit
Truss Cates.
Called Contact Person
a
Plan Check Balance.
Title 24 Calcs.
Plans picked up IUC4 f4p`
712-
construction
Flood plain plan
Plans resubmitted
Mechanical
Grading plan
2" Review, ready for corrections/issue
Electrical
Subcontactor List
Called Contact Person
Plumbing
Grant Deed
Plans picked up
S.M.I.
H.O.A. Approval
Plans resubmitted
Grading
IN HOUSE:-
Review, ready for correctionsfissuc
Developer Impact Fee
Planning Approval
Called Contact Person
A.I.P.P. Its
Pub. Wks. Appr
Date of permit issue
Scho6l Fees
Total Permit Fees
liz '(01
�oI41,14 011-011eA -
IV112,4
P -
0)
LA
MIN
DESCRIPTION
FINANCIAL INFORIVIATIM
ACCOUNT QTY
AMOUNT
PAID
PAID DATE
HOURLY PLAN CHECK - YES
101-0000-42600
2
$140.00
$0.00
PAID BY
METHOD
RECEIPT #
CHECK #
CLTD BY
Total Paid forCITY STAFF - PER HOUR:
$140.00
$0.00
DESCRIPTION
ACCOUNT
QTY
AMOUNT
PAID
PAID DATE
REMODEL, EA ADDITIONAL 500 SF
101-0000-42400
0
$48.62
$0.00
PAID BY .
METHOD
RECEIPT #
CHECK #
CLTD BY
DESCRIPTION:
ACCOUNT
QTY
AMOUNT
PAID
PAID DATE
REMODEL, FIRST 500 SF PC
101-0000-42600
0
$132.99
$0.00
PAID BY
METHOD
RECEIPT #
CHECK #
CLTD BY
Total Paid for REMODEL:
$181.61
$0.00
TOTALS:$0.00
Z Y.
T4ht
"
Building & Safety Department
78-495 Calle Tampico
La Quinta, CA 92253
(760) 777-7125 voice — (760) 777-7011 fax
To: Les Johnson, Community Development Director * To: PD: June 4, 2014
From: Greg .Butler, Building Official Due date: ASAP
Permit #14-774 Status: 1ST Review
Building Plans Approval
- (This is an approval to issue a Building Permit)
CVMSHCP Applicable Fee N/A
The Planning Department has reviewed the Building Plans for the following project:
Description: Remodel exterior balcony at Plaza La Quinta Shopping Center
Address or general location: 78-401 Highway 111, #C
Applicant Contact: Robert Ricciardi
The Planning Department finds that:
❑ ...these.Building Plans do not require Planning Department approval
..these Building Plans are approved by the Planning Department.
.❑ ....these Buildin Plans require corrections. Please forward a copy of the attached
corrections to a applicant. When the corrections are made please return them
;tothe lannin Department for review.
flo 11
Les Ahnson, cDhmunity Development Director Date
NOTE: LEAS RETURN PLANS WITH GREEN SHEET TO THE BUILDING AND
SAFETY A TMENT
I - BUILDING ENERGY ANALYSIS REPORT
PROJECT:
Plaza La Quinta Shopping CentIV
r
78-411 HWY 111
La Quinta , CA 92253 JUN 0 4 2014
CITY OF IA QUINTA
Project Designer: COMMUNITY DEVELOPMENT
Robert H. Ricciardi Architects
75-400 Gerald Ford Drive, Suite 115
Palm Desert, Ca 92211
(760) 408-1208
Report Prepared by:
• Jon Scott
Scott Design and Title 24, Inc,
°` ° 77-085 Michigan Drive
Palm Desert, Ca 92211
(760) 200-4780 Cf
Job Number:
Date:
5/22/2014
CITY OF LA QUINTA
BUILDING & SAFM L%EPT.
APPROVED
FOR:STRU'C�TIIOON
DA A-ey' '
The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is
authorized by the California Energy Commission for use with both the Residential and Nonresidential 2008 Building Energy Efficiency Standards.
rc; This program developed by EnergySoft, LLC — www.energysoff.com.
Pro.5.1 by EnergySoft User Number: 6712 Run Code: 201405-22T15:26:49 ID•
4
4
PERFORMANCE CERTIFICATE OF COMPLIANCE Part 1 of 3 PERF -1 C
Project Name
Date
Plaza La Quinta Shopping Center
5/22/2014
Project Address
Climate Zone
Total Cond. Floor Area
Addition Floor Area
78-411 HWY 111 La Quinta
CA Climate Zone 15
900
0
GENERAL INFORMATION
Building Type: m Nonresidential ❑ High -Rise Residential ❑ Hotel/Motel Guest Room
❑ Relocatable - indicate ❑ specific climate zone ❑ all climates
Phase of Construction: ❑ New Construction ❑ Addition ® Alteration
STATEMENT OF COMPLIANCE
This certificate of compliance lists the building features and specifications needed to
comply with Title 24, Parts 1 and 6 of the California Code of Regulations. This
certificate applies only to a Building using the performance compliance approach.
The documentation author hereby certifies that the documentation is accurate and complete.-,.,/
Documentation Author
Name Jon Scott
Signatur<S
Company Scoff Design and Title 24, Inc,
Date 522/2014
Address 77-085 Michigan Drive
Phone (760) 200-4780
City/State/Zip Palm Desert, Ca 92211
The Principal Designer hereby certifies that the proposed building design represented in this set of
construction documents is consistent with the other compliance forms and worksheets, with the specifications, and with
any other calculations submitted with this permit application. The proposed building has been designed to meet the energy
efficiency requirements contained in sections 110, 116 through 118, and 140 through 149 of Title 24, Part 6. Please
check one:
ENV. LTG. MECH.
I hereby affirm that I am eligible under the provisions of Division 3 of the Business and Professions Code to
❑ ❑ ❑ sign this document as the person responsible for its preparation; and that I am licensed in the State of
California as a civil engineer, mechanical engineer, electrical engineer, or I am a licensed architect.
1 affirm that I am eligible under the provisions of Division 3 of the Business and Professions Code by section
❑ ❑ ❑ 5537.2 or 6737.3 to sign this document as the person responsible for its preparation; and that I am a licensed
contractor performing this work.
I affirm that I am eligible under Division 3 of the Business and Professions ode o sign this document
13 13❑ because it pertains to a structure or type of work described as exempt pu o Business and Professions
Code Sections 5537, 5538 and 6737.1.
Principal Envelope Designer
Name Robert H. Ricciardi
Signature
(4xj . JAA
Company Robert H. Ricciardi Architects Date l
Address 75-400 Gerald Ford Drive, Suite 115 License # G-36,08
City/State/Zip Palm Desert, Ca 92211 Phone (760) 408-1208
Principal Mechanical Designer
Name
Signature
Company Mechanical Compliance Not /n the Scope Of This Submittal Date
Address License #
City/State/Zip Phone
Principal Lighting Designer.
Name
Signature
Company Lighting Compliance Not In The Scope Of This Submittal Date
Address License #
City/State/Zip Phone
INSTRUCTIONS TO APPLICANT COMPLIANCE & WORKSHEETS (check box if worksheets are included)
m ENV -1C Certificate of Compliance. Required on plans. ❑ MECH-1C Certificate of Compliance. Required on plans.
❑ LTG -1C Certificate of Compliance. Required on plans. ❑ MECH-2C Air/Water Side/Service Hot Water & Pool Requirements.
❑ LTG -2C Lighting Controls Credit Worksheet. ❑ MECH-3C Mechanical Ventilation and Reheat.
❑ ' LTG -3C Indoor Lighting Power Allowance. ❑ MECH-5C Mechanical Equipment Details.
EneTyPro 5.1 by EnergySoft User Number. 6712 Run Code: 2014-05-22715:26:49 /D: Page 3 of 11
PERFORMANCE CERTIFICATE OF COMPLIANCE Part 2 of 3 PERF -1 C
Project Name Date
laza La Quinta Shopping Center 5/22/2014
ANNUAL TDV ENERGY USE SUMMARY kBtu/s ft- r
Standard Proposed Compliance
Energy Component Design Design Mar in
Space Heating
Space Cooling
Indoor Fans
Heat Rejection
Pumps & Misc.
Domestic Hot Water
Lighting
Receptacle
Process
Process Lighting
TOTALS
4.23
2.03
2.20
515.13
450.30
64.83
78.07
75.80
2.27
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
184.10
184.10
0.00
91.38
91.38
0.00
0.00
0.00
0.00
0.00
0.00
0.00
872.91
803.61
69.31
Heating
Cooling
Fans
Heat Rej
Pumps
DHW_-
Lighting a
Receptacle "
Process - -
Process Ltg -
Percent better than Standard 7.9%1 7.9 i excluding process)
BUILDING COMPLIES
GENERAL INFORMATION
Building Orientation (SK9 225 deg Conditioned Floor Area 900 sqft.
Number of Stories 2 Unconditioned Floor Area 0 sqft.
Number of Systems 1 Conditioned Footprint Area 0 sqft.
Number of Zones 1 Natural Gas Available On Site yes
Orientation Gross Area Glazina Area Glazina Ratin
Front Elevation
Left Elevation
Rear Elevation
Right Elevation
Total
Roof
(SK9
920
(NM
1,040
(NE)
180
(SE)
1,040
3,180
900
sqft.
sqft.
sqft.
sqft.
sqft.
sgft.
112
144
0
0
256
0
sqft.
sqft.
sqft.
sqft.
sqft.
sqft.
12.2
13.8
0.0%
0.0%
8.1
0.0%
Standard Proposed Prescriptive Values for
Prescriptive Lighting Power Density 1.600 W/sgft. 1.60o W/sqft. Comparison only. See
Prescriptive Envelope TDV Energy 75,992 87,563 LTG -1 C for allowed LPD.
Remarks:
Ene Pro 5.1 6 Ene Soft User Number: 6712 Run Code: 2014-05-22715:26:49 /D: Page 4 of 11
F'
4
PERFORMANCE CERTIFICATE OF COMPLIANCE Part 3 of 3 PERF -1 C
Project Name
Plaza La Quinta Shopping Center
Date
5/22/2014
ZONE INFORMATION
System Name
Zone Name
Occupancy Type
Floor
Area
s ft.
Inst.
LPD
W/Sf'
Ctrl.
Credits
W/sf 2
Allowed LPD
Proc.
Loads
W/Sf
Area Tailored
W/sf 3 W/sf "
HVAC Existing
Existing Building
Retail Sales, Wholesale
900
"1.600
Notes: 1. See LTG -1C 2. See LTG -2C 3. See LTG -3C 4. See LTG -4C
items marked with asterisk see LTG -1-C b others b others
Items above require special documentation
EXCEPTIONAL CONDITIONS COMPLIANCE CHECKLIST
The local enforcement agency should pay special attention to the items specified In this checklist. These items require special written
justification and documentation, and special verification to be used with the performance approach. The local enforcement agency
determines the adequacy of the justifications, and may reject a building or design that otherwise complies based on the adequacy of the
special justification and documentation submitted.
The exceptional features listed in this performance approach application have specifically been reviewed. Adequate written justification and
documentation for their use have been provided by the applicant.
Authorized Signature or Stamp
EneigyPro 5.1 by EnergySoft User Number: 6712 RunCode: 2014-05-22T15:26:49 /D: Page 5 of 11
•
•
CERTIFICATE OF COMPLIANCE (Part 1 of 3) ENV -1 C
AND FIELD INSPECTION ENERGY CHECKLIST
Project Name
Plaza La Quinta Shopping Center
Date
5/22/2014
Project Address
78-411 HWY 111 La Quinta
Climate Zone
15
Total Cond. Floor Area
900
Addition Floor Area
0
GENERAL INFORMATION
Building Type: m Nonresidential ❑ High -Rise Residential ❑ Hotel/Motel Guest Room
❑ Schools (Public School) ❑ Bledlocatable g. Public School m Conditioned Spaces ❑ Unconditioned Spaces
❑ Skylight Area for Large Enclosed Space i 8000 ft2 (If checked include the ENV -4C with submittal)
Phase of Construction: ❑ New Construction ❑ Addition m Alteration
Approach of Compliance: ❑ Component m Overall Envelope ❑ Unconditioned (file affidavit)
Front Orientation: N, E, S, W or in Degrees:
225 deg
FIELD INSPECTION ENERGY CHECKLIST
OPAQUE SURFACE DETAILS
INSULATION
Ta /ID
AssemblyType
y
Q
c
C
d uj
OZ
M
... 7
�;
VM
OE
°
d 7
W>
° C
d
WU.
C
d
'E >
M IM
° C
d
LLL
�
C
C a
�Q
r N
C%
UN
N
a
IL
1.
Roof
900
(N)
0.049
R-19
4.2.1-A4
Existing
❑
❑
2
Wall
180
(NE)
0.044
R-13
13.0
None
4.3.1-A3
Existing
❑
❑
3
Wall
1,040
(SE)
0.044
R-13
13.0
None
4.3.1-A3
Existing
❑
❑
4
Wall
808
(SW
0.044
R-13
13.0
None
4.3.1-A3
Existing
❑
❑
5
Wall
896
(NM
0.044
R-13
13.0
None
4.3.1-A3
Existing
❑
❑
❑
❑
❑
❑
❑
❑
❑
❑
❑
❑
1. See Instructions in the Nonresidential Compliance Manual, page 3-96.
2. If Fail, then describe on Page 2 of the Inspection Checklist Form and take appropriate action to correct. A fail does not meet compliance.
FENESTRATION SURFACE DETAILS
Tag/ID
Fenestration
T e
a
c3:
A C
c z
O
°
A
2>
v
LL 'o
> N
C7
=
2—
d
U w
= o'
(n N
R
t
>
O
T3 5
co -5
v 6
)
0.
A
a
1
Window
112
(SVIO
0.560
NFRC
0.460
NFRC
❑
Existing
❑
❑
2
Window
224
(NK9
0.560
NFRC
0.460
NFRC
❑
Removed
❑
❑
3
Window
144
(NVO
0.510
NFRC
0.390
NFRC
❑
New
❑
❑
❑
❑
❑
❑
❑
1 ❑
❑
❑
❑
❑
❑
❑
❑
❑
❑
E❑
O
❑
❑
❑
❑
1. See Instructions in the Nonresidential Compliance Manual, page 3-96.
2. If Fail then describe on Page 2 of the Inspection Checklist Form and take appropriate action to correct. Verify building plans if necessary.
EnergyPro 5.1 by EnergySoft User Number: 6712 Run Code: 2014.05-22715:26:49 /D: Page 6 of 11
W
C�
J
C
CERTIFICATE OF COMPLIANCE (Part 2 of 3)
AND FIELD INSPECTION ENERGY CHECKLIST
ENV -1 C
Project Name
Plaza La Quinta Shopping Center
Date
5/22/2014
ROOFING PRODUCT COOL ROOFS
(Note if the roofing product is not CRRC certified, this compliance approach cannot be used). Go to Overall Envelope Approach or
Performance Approach.
CHECK APPLICABLE BOX BELOW IF EXEMPT FROM THE ROOFING PRODUCT "COOL ROOF" REQUIREMENTS:
Pass
Fail'
N/A
❑ Roofing compliance not required in Climate Zones 1 and16 with a Low -Sloped. 2:12 pitch or less.
❑
❑
❑
❑ Roofing compliance not required in Climate Zone 1 with a Steep -Sloped with less than 5 Ib/ftZ. Greater than 2:12 pitch.
❑
❑
❑
❑ Low -sloped Wood framed roofs in Climate Zones 3 and 5 are exempted, solar reflectance and thermal emittance or
that have a U -factor of 0.039 or lower. See Opaque Surface Details roof assembly, Column H of ENV -2C.
E3
13
13SRI
❑ Low -sloped Metal building roofs in Climate Zone 3 and 5 are exempted, solar relectance and thermal emittance or SRI
that have a U -factor of 0.048 or lower. See Opaque Surface Details roof assembly below, Column H of ENV -2C.
❑
❑
❑
❑ The roof area covered by building integrated photovoltaic panels and building integrated solar thermal panels are
exempted. Solar reflectance and thermal emittance or SRI, seespreadsheet calculator at www.energy.ca. ov/title24/
❑
❑
❑
❑ Roof constructions that have thermal mass over the roof membrane with a weight of at least 25 Ib/ft are exempt from
Cool Roof criteria below.
11
13
13the
❑ High-rise residential buildings and hotels and motels with low -sloped roofs in Climate Zones 1 through 9, 12 and 16 are
ted from the low -sloped roofingcriteria.
1313
13exem
1. If Fail then describe on this page of the Inspection Checklist Form and take appropriate action to correct. Verify building plans if necessary.
CRRC Product ID
Number'
Roof Slope
s 2:12 > 2:12
Product Weight
< 51b/f? z 51b/ft2
Product
Type 2
Aged Solar
Reflectance
Thermal
Emmitance
SIR 15
Pass
Fai16
❑ ❑
❑ ❑
❑ 4
❑
❑
❑ ❑
❑ ❑
❑4
❑
❑
❑ ❑
1 ❑ ❑
❑4
❑
❑
❑ ❑
❑ ❑
❑ 4
❑
❑
❑ ❑
❑ ❑
❑ 4
❑
❑
❑ ❑
❑ ❑
❑ 4
❑ 1
❑
1. The CRRC Product ID Number can be obtained from the Cool Roof Rating Council's Rated Product Directory at
www.coolroofs.org/r)roducts/search.r)hr)
2. Indicate the type of product is being used for the roof top, i.e. single -ply roof, asphalt roof, metal roof, etc.
3. If the Aged Reflectance is not available in the Cool Roof Rating Council's Rated Product Directory then use the Initial Reflectance value from the
same directory and use the equation (0.2+0.7(p;Nt;a, — 0.2) to obtain a calculated aged value. Where p is the Initial Solar Reflectance from the Cool
Roof Rating Council's Rated Product Directory.
4. Check box if the Aged Reflectance is a calculated value using the equation above.
5. The SRI value needs to be calculated from a spreadsheet calculator at httr)://www.energy.ca.aov/title24/
6. If Fail then describe on this page of the Inspection Checklist Form and take appropriate action to correct. Verify building plans if necessary.
To apply Liquid Field Applied Coatings, the coating must be applied across the entire roof surface and meet the dry mil thickness or coverage
recommended by the coatings manufacturer and meet minimum performance requirements listed in §118(i)4. Select the applicable coating:
❑ Aluminum -Pigmented Asphalt Roof Coating
❑ Cement -Based Roof Coating
❑ Other
Discrepancies:
EnemyPro 5.1 by EneMySoft User Number: 6712 RunCode: 2014-05-22715:26:49 /D:
Pae 7 of 11
n
LI
•
u
CERTIFICATE OF COMPLIANCE (Part 3 of 3) ENV -1 C
AND FIELD INSPECTION ENERGY CHECKLIST
Project Name
Plaza La Quinta Shopping Center
Date
5/22/2014
Required Acceptance Tests
Designer:
This form is to be used by the designer and attached to the plans. Listed below is the acceptance test for Envelope
Fenestrations system. The designer is required to check the acceptance tests and list all the fenestration products that
require an acceptance test. If all the site -built fenestration of a certain type requires a test, list the different fenestration
products and the number of systems. The NA7 Section in the Appendix of the Nonresidential Reference Appendices
Manual describes the test. Since this form will be part of the plans, completion of this section will allow the responsible
party to budget for the scope of work appropriately.
Enforcement Agency:
Systems Acceptance. Before Occupancy Permit is granted for a newly constructed building or space or whenever new
fenestration is installed in the building or space shall be certified as meeting the Acceptance Requirements.
The ENV -2A form is not considered a complete form and is not to be accepted by the enforcement agency unless the
boxes are checked and/or filled and signed. In addition, a Certificate of Acceptance forms shall be submitted to the
enforcement agency that certifies plans, specifications, installation certificates, and operating and maintenance
information meet the requirements of §10-103(b) of Title 24 Part 6. The field inspector must receive the properly filled
out and signed forms before the building can receive final occupancy. A copy of the ENV -2A for each different
fenestration product line must be provided to the owner of the building for their records.
Test Description ENV -2A Test Performed By:
Fenestration Products Name or ID Area of like Building Envelope
Requiring Testing or Verification Products Acceptance Test
Double Metal TINT 144
❑
13
13
13
13
13
13
13
13
EnergyPro 5.1 by EnergySoft User Number: 6712 RunCode: 2014-05-22T15:26:49 ID: Page 8 of 11
ENVELOPE MANDATORY MEASURES: NONRESIDENTIAL ENV -MM
Project Name
Plaza La Quinta Shopping Center
Date
5/22/2014
DESCRIPTION
Building Envelope Measures:
§118(a): Installed insulating material shall have been certified by the manufacturer to comply with the California Quality
Standards for insulating material, Title 20 Chapter 4, Article 3.
§118(c): All Insulating Materials shall be installed in compliance with the flame spread rating and smoke density requirements of
Sections 2602 and 707 of Title 24, Part 2.
§118(f): The opaque portions of framed demising walls in nonresidential buildings shall have insulation with an installed R -value
of no less than R-13 between framing members.
§117(a): All Exterior Joints and openings in the building that are observable sources of air leakage shall be caulked, gasketed,
weatherstripped or otherwise sealed.
Manufactured fenestration products and exterior doors shall have air infiltration rates not exceeding 0.3 cfm/ft.2 of
§116(a) 1: window area, 0.3 cfm/ft.2 of door area for residential doors, 0.3 cfm/ft.2 of door area for nonresidential single doors
(swin-ging and sliding),and 1.0cfm/ft.2 for nonresidential double doors (swinging).
§11.6(a) 2: Fenestration U -factor shall be rated in accordance with NFRC 100, or the applicable default U -factor.
§116(a) 3: Fenestration SHGC shall be rated in accordance with NFRC 200, or NFRC 100 for site -built fenestration, or the
applicable default SHGC.
§11.6(b): Site Constructed Doors, Windows and Skylights shall be caulked between the unit and the building, and shall be
weatherstripped (except for unframed glass doors and fire doors).
EnemvPro 5.1 by Ene Sof User Number: 6712 Run Code: 2014-05-22715:26:49 /D: Pa e 9 of 11
CJ
C,
J
�i
LIGHTING MANDATORY MEASURES: NONRESIDENTIAL LTG -MM
Project Name
Date
Plaza La Quinta Shopping Center
5/22/2014
Indoor Lighting
Measures:
§131(d): Shut-off Controls
For every floor, all interior lighting systems shall be equipped with a separate automatic control to shut off the lighting.
1.
This automatic control shall meet the requirements of Section 119 and may be an occupancy sensor, automatic time
switch or other device capable of automatically shutting off the lighting.
2
Override for Building Lighting Shut-off: The automatic building shut-off system is provided with a manual, accessible
override switch in sight of the lights. The area of override is not to exceed 5,000 square feet.
§119(h):
Automatic Control Devices Certified: All automatic control devices specified are certified, all alternate equipment shall
be certified and installed as directed by the manufacturer.
§111:
Fluorescent Ballast and Luminaires Certified: All fluorescent fixtures specified for the project are certified and listed in the
Directory. All installed fixtures shall be certified.
§131(a):
Individual Room/Area Controls: Each room and area in this building is equipped with a separate switch or occupancy
sensor device for each area with floor -to -ceiling walls.
Uniform Reduction for Individual Rooms: All rooms and areas greater than 100 square feet and more than 0.8 watts
§131(b):
per square foot of lighting load shall be controlled with bi-level switching for uniform reduction of lighting within the
room.
Daylight Area Control: All rooms with windows and skylights that are greater than 250 square feet and that allow for
§131(c):
the effective use of daylight in the area shall have 50% of the lamps in each daylit area controlled by a separate switch;
or the effective use of daylight cannot be accomplished because the windows are continuously shaded by a building on
the adjacent lot. Diagram of shadinq during different times of the year is included on plans.
§131(c):
Display Lighting. Display lighting shall be separately switched on circuits that are 20 amps or less.6.
Outdoor Lighting Measures:
§130(c)1:
Mandatory lighting power determination for medium base sockets without permanently installed ballasts
§132(a):
All permanently installed luminaires with lamps rated over 100 Watts either have a lamp efficacy of at least 60 lumens
per Watt or are controlled by a motion sensor.
§132(b):
All Luminaires with lamps rated greater than 175 Watts in hardscape area, including parking lots, building entrances,
canopies, and all outdoor sales areas meet the Cutoff Requirements.
§132(c)1:
All permanently installed outdoor lighting meets the control requirements listed.
§132(c):
Building facades, parking lots, garages, canopies, and outdoor sales areas meet the Multi -Level Lighting Requirements
listed. .
EnergyPro 5.1 by
EnergySoft User Number 6712 RunCode: 2014-05-22T15:26:49 /D: Pae 10 of 11
•
•
•
MECHANICAL MANDATORY MEASURES: NONRESIDENTIAL MECH-MM
Project Name
Date
Plaza La Quinta Shopping Center
5/22/2014
Equipment and System Efficiencies
§111:
Any appliance for which there is a California standard established in the Appliance Efficiency Regulations will comply
with the applicable standard.
§115(a):
Fan type central furnaces shall not have a pilot light.
§123:
Piping, except that conveying fluids at temperatures between 60 and 105 degrees Fahrenheit, or within HVAC
equipment, shall be insulated in accordance with Standards Section 123.
§124:
Air handling duct systems shall be installed and insulated in compliance with Sections 601, 602, 603, 604, and 605 of
the CMC Standards.
Controls
§122(e):
Each space conditioning system shall be installed with one of the following:
1A.
Each space conditioning system serving building types such as offices and manufacturing facilities (and all others not
explicitly exempt from the requirements of Section 112 (d)) shall be installed with an automatic time switch with an
accessible manual override that allows operation of the system during off -hours for up to 4 hours. The time switch
shall be capable of programming different schedules for weekdays and weekends and have program backup
capabilities that prevent the loss of the device's program and time setting for at least 10 hours if power is interrupted; or
1 B.
An occupancy sensor to control the operating period of the system; or
1 C.
A 4 -hour timer that can be manually operated to control the operating period of the system.
2
Each space conditioning system shall be installed with controls that temporarily restart and temporarily operate the
system as required to maintain a setback heating and/or a setup cooling thermostat setpoint.
Each space conditioning system serving multiple zones with a combined conditioned floor area more than 25,000
§122(8)'
square feet shall be provided with isolation zones. Each zone: shall not exceed 25,000 square feet; shall be provided
with isolation devices, such as valves or dampers that allow the supply of heating or cooling to be setback or shut off
independently of other isolation areas; and shall be controlled by a time control device as described above.
§122(c):
Thermostats shall have numeric setpoints in degrees Fahrenheit (F) and adjustable setpoint stops accessible only to
authorized personnel.
§122(b):
Heat pumps shall be installed with controls to prevent electric resistance supplementary heater operation when the
heating load can be met by the heat pump alone
Each space conditioning system shall be controlled by an individual thermostat that responds to temperature within the
zone. Where used to control heating, the control shall be adjustable down to 55 degrees F or lower. For cooling, the
§122(a&b):
control shall be adjustable up to 85 degrees F or higher. Where used for both heating and cooling, the control shall be
capable of providing a deadband of at least 5 degrees F within which the supply of heating and cooling is shut off or
reduced to a minimum.
Ventilation
§121(e):
Controls shall be provided to allow outside air dampers or devices to be operated at the ventilation rates as specified
on these plans.
122 f
§ ()'
All gravity ventilating systems shall be provided with automatic or readily accessible manually operated dampers in all
openings to the outside, except for combustion air openings.
Ventilation System Acceptance. Before an occupancy permit is granted for a newly constructed building or space, or a
§121(f):
new ventilating system serving a building or space is operated for normal use, all ventilation systems serving the
building ors ace shall be certified as meeting the Acceptance Requirements for Code Compliance
Service Water Heating Systems
§113(c)
Installation
3.
Temperature controls for public lavatories. The controls shall limit the outlet Temperature to 110° F.
2
Circulating service water -heating systems shall have a control capable of automatically turning off the circulating pump
when hot water is not required.
EnergyPro 5. 1 by
EnergySoft User Number: 6712 Run Code: 2014-05-22715:26:49 /D: Pae 11 of 11