Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
10-0127 (RC)
.- - P.O. BOX 1504 78-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 r it / 1 4 BUILDING & SAFETY DEPARTMENT BUILDING PERMIT Application Number: .. 10-0000012-7 Property Address: 78445 HIGHWAY 111 APN: 604-050-008- - - Application description: REMODEL - -COMMERCIAL Property Zoning: COMMUNITY COMMERCIAL Application valuation: 50000 Applicant: Architect or Engineer: ------------------ LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professionals Code, and my License is in full force and effect. License Class: B License No.: 585025 f Date: Contraaor� *WAWA" A&6J2V4=_ OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the following reason (Sec. 7031 .5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: (_) I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, . and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). 1 _ 1 I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). ' ( ) I am exempt under Sec. , B.&P.C. for this reason Date: Owner: CONSTRUCTION LENDING AGENCY 1 hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). r Lender's Name: Lender's Address: LQPERA11T ' Owner: M & H REALTY -PARTNERS II C/O PETER MERLONE 353 SACRAMENTO ST 21ST FL SAN FRANCISCO, CA 94111 Contractor: MANN CONSTRUCTION 11827 ABINGTON STREET RIVERSIDE, CA 92503 (951)275-4964 Lic. No.: 585025 VOICE (760) 777-7012 FAX (760) 777-7011 INSPECTIONS (760) 777-7153 U Date: 5/10/10 0 2010 LA AUINIA -------------\3700o -----------------------------— ORKER'S COMPENSATION DECLARATION I hereby affirm under penalty e of the following declarations: I have and will mtificate of consent to self -insure for workers' compensation, as provided for by Sectione Labor Code, for the performance of the work for which this permit is issued. I have and will mers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier EXEMPT Policy Number EXEMPT 1 certify that, in the performance of the work for which this permit is issued, 1 shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, if 1 should become subject to the workers' compensation provisions of Section 3700 of the Labor Code, I shall forthwith comply with those provisions. . Date:./Q/o Applicant: WARNING: FAILURE TO SECURE WORKERS' COMPENSATION UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the conditions and restrictions set forth on this application. 1. Each person upon whose behalf this application is made, each person at whose request and.for whose benefit work is performed under or pursuant to any permit issued as a result of this application, the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. y . �I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this county to enter upon the above-mentioned property for inspection purposes. Dat,: !f/D•�DSignatuure (Applicant. or Agent): Application Number . . . . . 10-00000127 ------ Structure Information 2494 SF T.I. ----- Construction Type . . . TYPE V, UNPROTECTED Occupancy Type . . . . . BUSINESS <50 Other struct.info . . . . . CODE'EDITION 2007/08 ENERGY MIXED-USE OCCUPANCY B OCCUPANT LOAD 50.00 1ST FLOOR SQUARE FOOTAGE 2494.00 ---------------------------------------------------------------------------- 2ND FLOOR SQUARE FOOTAGE .00 Permit . . . . . BUILDING PERMIT Additional desc . - -- -" Permit -Fee . . . .""- 414.50 Plan Check Fee 269.43 Issue Date . . . . Valuation . . . . 50000 Expiration Date 11/06/10 Qty Unit Charge Per Extension BASE FEE 252.00 25.00 6.5000 ---------------------------------------------------------------------------- THOU BLDG 25,001-50,000 162.50 Permit . . . ELECT - ADD/ALT/REM Additional desc . Permit Fee . . . . 83.10 Plan Check Fee 20.78 Issue Date Valuation . . . . 0 Expiration Date 11/06/10 Qty Unit Charge Per Extension BASE FEE 15.00 20.00_ .7500 PER ELEC DEVICE/FIXTURE 1ST 20 15.00 118.00 .4500 EA ELEC DEVICE/FIXTURE >20 53.10 Permit MECHANICAL Additional desc . Permit Fee . . . . 39.50 Plan Check Fee 9.88 - Issue Date . . . . Valuation . . . . 0 Expiration Date'. 11/06/10 Qty Unit Charge Per Extension BASE FEE 15.00 2.00 4.500.0 EA MECH VENT INST/ DUCT ALT 9.00 1.00 9•.0000 EA MECH APPL REP/ALT/ADD 9.00 1.00 6.5000 EA MECH VENT FAN 6.50 Permit. . . . . . . PLUMBING LQPERMIT Application Number . . . . . 10-00000127. Permit . . . PLUMBING Additional desc . Permit Fee . . . . 160.50 Plan Check Fee 40.13 Issue.Date . . . . Valuation . . . . 0 Expiration Date 11/06/10 Qty Unit Charge Per Extension BASE FEE 15.00 21.00 6.0000 EA PLB FIXTURE 126.00 1.00 7.5000 EA PLB WATER HEATER/VENT 7.50 1.00 3.0000 EA PLB WATER INST/ALT/REP 3.00 1.00 3.0000 EA PLB FIXTURE DRAIN/VENT REP/ALT 3.00 2.00 3.0000 EA PLB GAS PIPE 1-4 OUTLETS 6.00 -------------------------------------------------------------------------- Special Notes and Comments 2494 SF TENANT IMPROVEMENT FOR NAIL SALON. "B" OCCUPNCY, TYPE VB, CONSTRUCTION. OCCPANT LOAD = 50. 2 EXITS REQUIRED. 2007 CODES / 2008 ENERGY. TENANT: "CITY NAILS 2" ' ---------------------------------------------------------------------------- Other Fees . . . . . . . . . ACCESSIBILITY PLAN REVIEW 26.94 BLDG STDS ADMIN (SB1473) 2.00 ENERGY REVIEW FEE 26.94 Fee summary Charged Paid Credited Due ----------------- Permit Fee Total 697.60' .00 .00 69'7.60 Plan Check Total 340.22 .00 .00 340.22 Other Fee Total 55.88 .00 .00 55.88 Grand Total 1093.70 .00 .00 1093.70 Bin # '' 4 Qty of is Quinta Building &r Safety Division P.O. Box 1504, 78-495 Calle Tampico La Quinta, CA 92253 - (760) 777-7012 Building Permit Application and Tracking Sheet Permit # Project Address: 79- ogy 14WA-Y II I Su 1 TE7, q #.f' Owner's Name: NA I-Mu D/6P A. P. Number: Address: 787/S NA PL E Legal Description: Contractor: MAN4 COWS—MUCTIOA) Address: I g Z7 A B,Aj(,TOA) S-T. City, ST, Zip: L-At Nut"J-7,4 C.4 92253 Telephone: (-7(o o ) 7,7 — 4 73 6 Project Description: City, ST; Zip: RIVERSIDG: CA 1725D3 Telephone: Ctfl-a75— qqb:tl 'PAR-1QfJ -azallel—, State Lic. # 5.0 z 6- City Lic. #.-. Arch., Engr., Designer: ICA/- 13trURT, AA,1V 267—OC47&— RxS Address: Qbox 26-1-7 City.,ST,Zip: Y- Telephone: 5/-a33 -99 10 StateLic.#: -6o?36 Name of Contact Person: Construction pe: PProject type (Ale one): New Add'n (Alter) Repair Demb Sq. Ft.: -Z # Stories: #Units: Telephone # of Contact Person: (9 a�3 3-,83 to Estimated Value of ProiectIs APPLICANT: DO NOT WRITE BELOW THIS LINE # Submittal Req'd Reeld TRACKING PERMIT FEES Plan Sets Plan Check submi tt 7 Lh'L Item Amount Structural Calcs. Reviewed, ready forrection, Ko —1) .1 V— Plan Ch . eck Deposit Truss Cales. Called Contact Pe 4's Plan Check Balance. Title 24 Cates. Plans picked up U Construction Flood plain plan Plans resubmitted Mechanical Grading plan 2" Review, ready for correction ' ss U ) Electrical Subcontactor List Called Contact Person Ijj Plumbing Grant Deed Plans picked up S.M.I. H.O.A. Approval Plans resubmitted Grading IN HOUSE:- Review, ready for corrections/issue Developer Impact Fee Planning Approval Called Contact Person A.I.P.P, Pub. Wks. Appr Date or permit issue School Fees Total Permit Fees P.O. BOX 1504 BUILDING & SAFETY DEPARTMENT 78-495 CALLE TAMPICO (760) 777-7012 LA QUINTA, CALIFORNIA 92253 FAX (760) 777-7011 To: Greg Butler, Building & Safety Manager To PD: 03-09-10 From: Les Johnson, Director -PDD Due Date: 03-16-10 Permit #: Status: 1ST REVIEW Building PlansApproval r ` (This is an approval to issue a Building Permit) The Planning Department has reviewed 'the Building Plans for the following project: .Description: TENANT IMPROVEMENT (SALON) Address or General Location: 78-445 HIGHWAY 111 STE. 445 Applicant Contact: DU LU (951)-233-8810 The Planning Development Department finds that: ❑ ...these Building Plans do not require Planning Department approval. ..these Building Plans are approved by the Planning Department. ❑ ...these Bdilding Plans require corrections. Please forward a copy of the attached corrections to the applicant. When the corrections are made please return them to the Planning Department for review. IA— +-IZ•IO Les John4oli, Director -PD Date o received MAIC 0 9 20110 City of La Qulnta Plaming Department I Bin # �p City of La Quinta Building & Safety Division Box 1504, 78-495 Calle Tampico 1 La Quinta, CA 92253 - (760) 777-7012 Building Permit Application and Tracking Sheet PerP.O. D . I �t � l Prof U� �7 1� �.w ((( Sr.. Yur A P. Number. Legal Description: p`" °–� Contractor: A 4� Owner's Name: Address: ✓ City, ST, Zip: Telephone: - ,,::, Project Description: ` Address: �(�_ p a3� City, ST, Zip:Sj ( cTelephone:State Oci�'Lic Lic. # : o . #; Arch., Engr., Designer. Address: -? --� City., ST, Zip: vt'r5t �i_.�2Zf-?, Telephone: CS 29S —$8( Q State Lic. #: Name of Contact Parson: Construction Type Occupancy: Project type (circle one): New Add'n Allier Repair Demo Sq. Ft.: 2057 # Stories: # Units: Telephone # of Contact Person: &6 '2S� Estimated Value of Project: APPLICANT: DO NOT WRITE BELOW THIS UNE # Submittal Req'd Recd TRACKING PERMIT FEES Plan Sets Plan Check submitted /Q Item Amount Structural Cafes.Reviewed, ready for corrections Plan Check Deposit Tress Cala.. Called Contact Person Plan Check Balance Title Zd Calca Planspicked up Construction Flood plain plan Plans resubmitted Mechanical Grading plan 2" Review, ready for corrections/issue Electrical Subeontaetor List Called Contact Person Plumbing Grant Deed Plans picked up S.K.I. H.O.A. Approval Plans resubmitted Grading IN HOUSE:- Review, ready for correcdoas/rssue Developer Impact Fee Planning Approval Called Contact Person ` .LP -P. Pub. Wks. Appr Date of permit issue School Fees Total Permit Fees John R. Hawkins Fire Chief Proudly serving the unincorporated areas of Riverside County and the Cities of: Banning 4. . Beaumont 4. Calimesa Canyon Lake .; Coachella Desert Hot Springs Indian Wells 4. Indio Lake Elsinore La Quinta Moreno Valley Palm Desert Perris Rancho Mirage Rubidoux CSD 4. San Jacinto 4. Temecula Board of Supervisors Bob Buster, District 1 John Tavaglione, District 2 Jeff Stone, District 3 Roy Wilson, District 4 Marion Ashley, District 5 RIVERSIDE COUNTY FIRE DEPARTMENT In cooperation with the California Department of Forestry and Fire Protection 77-933 Las Montanas Rd STE 201 . Palm Desert, CA 92211 March 29, 2010 863-8886;d Fax (760) 863-7072 RE: TENANT IMPROVEMENT PLAN CHECK LAQ-IO-TI-009 City Nails 2 78-445 Hwy 111 Suite 445 La Quinta, CA You have been issued a release for a tenant improvement on an existing building. THIS IS NOT AN OCCUPANCY PERMIT. It is prohibited to use/process or store any materials in this occupancy that would classify it as an "H" occupancy per Sec. 307 of the 20007 UBC. THE FOLLOWING CONDITIONS MUST BE MET PRIOR TO INSPECTION: Install door hardware and exit signs as per Chapter 10 of the 2007 UBC. A minimum 2A1OBC Fire Extinguisher, (State Fire Marshal Approved) must be mounted in a visible location within 75' walking distance from any point in your building or suite. Fire extinguishers can be installed by a licensed extinguisher company with a State Fire Marshal service tag attached to the extinguisher, or purchased from a retail store with a sales receipt attached. A licensed fire extinguisher company must service extinguisher yearly. All breakers must be labeled and a clearance of 36 inches must be maintained around the panel at all times. A durable sign stating "This door to remain unlocked during business hours" shall be placed on or adjacent to the front exit door. The sign shall be in letters not less than one inch high on a contrasting background. Provide key(s) to the tenant space for inclusion in the main building Knox Box. Key(s) shall have durable and legible tags affixed for identification of the correlating tenant space. Key(s) shall be provided at time of final inspection. An approved audible interior notification alarm device shall be provided in approved locations. A C-10 licensed contractor must submit plans, designed in accordance with NFPA 72 to the Fire Department for review and approval prior to installation. As may be necessary to maintain proper fire sprinkler protection due to constructions changes, fire sprinkler system plans for the tenant improvement. area may be required to be submitted to the Fire Department for review. Approved suite address shall be placed in such a position to be plainly visible and legible from the street. Said numbers shall contrast with their background. Applicant/installer shall be responsible to contact the Fire Department to schedule inspections. A re- inspection fee will be required if more than one (1) inspection is necessary. Requests for inspections are to be made at least 72 hours in advance and may be arranged by calling (760) 863-8886. • All questions regarding the meaning of these conditions should be referred to the Fire Department Planning & Engineering Staff at (760) 863-8886. • Sincerely, 4 By: Jason Stubble Fire Safety Specialist t i OWNER MANUA PLEASE SAVE THIS MANUAL FOR FUTURE REFERENCE FOOT -SPA CITY OF LA QU BUILDING & SAFETY DEPT. Chair 9600 Patent Pending 4��= CNS C E APPROVED •••• FOR CONSTRUCTION Gwtreat DATE Z fl BY eanjet®, La TulipT1 Gulfstream Inc are trademarks of Gulfstream Inc. 4 ID ` �,2, Patent #D610697, #13600950 © 2010 All rights reserved. Design and Specifications are subject to change without not# Table of Contents Owner Mahual Safety and Precautions ......................................................................... 1-2 IdentifyingParts ................................................................................... 3-4 Foot -spa Clearance ............................................................................. 5 INSTALLATIONS Attaching, Seat ......................................................................... 6 JetAssembly ......................................................................... 7-9 Plumbing Connections ............ .................................................... 10 Operations and Use ......................................................................... 11-13 Cleaning& Maintenance ..................................................................... 14 Warranty & Service ......................................................................... 15 Thank you for purchasing the La Tulip spa from Gulfstream Inc. Please carefully read the instructions before installing the spa. Carefully follow the instructions, your spa will give you years of beauty and service. This product is to be connected to a branch circuit outlet protected by a Class A GROUND FAULT CIRCUIT INTERRUPTER (GFCI), and the GFCI shall be tested regularly for continued protection and correct operation. If a Class A GFCI protected outlet is not available, DO NOT USE THIS PRODUCT! Please contact a licensed electrician for installation of a Class A GFCI according to local electric codes, or equivalent. AWarning THIS PRODUCT IS FOR IN DOOR USE ONLY DISCONNECT POWER SUPPLY CORD BEFORE SERVICING AND CLEANING Foot -spa must be installed by a licensed plumber and electrician in accordance with local codes. Plumbing and Electrical Installation instructions must be adhered to in order for the warranty to be in effect and to insure the utmost in safety. Chair and spa have a maximum seating capacity of 350 pounds. The foot -spa is not intended to be stood in or used as a step. The portable foot -spa model is movable, standing in tub or using as a step may cause severe damage to the unit as well as possible serious injury to the person. If a crack occurs in the glass bowl, DO NOT manually handle the bowl unless the proper attire is worn. Q Warning Under no circumstances must the bowl be used by your customers as you can be held accountable for any injury that may occur. Gulfstream is not liable for any injury that may occur. BASIC PRECAUTIONS SHOULD ALWAYS BE OBSERVED, INCLUDING THE FOLLOWING: 1. Read and follow all instructions 2. DANGER. To reduce the risk of injury, do not permit children to use this unit unless they are supervised at all times 3. Use this unit only for its intended use as described in this manual. Do not use attachments that are not recommended by the manufacturer. 4. Never drop or insert any object into any opening. 5. Do not block jets during whirlpool operation. 6. The unit must be connected to an electrical supply circuit that is protected by a ground fault circuit interrupter. 7. The clean jet motor is magnetically driven and is insulated twice. Therefore it does not require to be bonded. Save these instructions 1. Excessive water temperature is dangerous and should be checked BEFORE use. Warning 2. Maximum temperature of the water should never exceed 100 degrees F. 3. Always enter and exit the Foot Spa slowly and carefully. 4. NEVER bring and / or operate any electrical devices into or near the Foot Spa. <p� GROUNDING METHODS Because this unit must be connected to a circuit with a ground -fault circuit interrupter (GFCI), DO NOT use a grounding adapter. The use of a grounding adapter is prohibited in Canada by Part I of the Canadian Electrical Code. GROUNDING INSTRUCTIONS This appliance must be plugged into an outlet equipped with a ground -fault circuit interrupter. The ground -fault interrupter can be in the out -let shown in illustration A or in the circuit breaker (fuse) box. If your outlet or circuit breaker (fuse) box is not equipped with a ground -fault interrupter, you must have your electrician install one. In the event of an electrical short-circuit, the ground -fault circuit interrupter will turn off the electrical power to the unit immediately, greatly reducing the likelihood of serious injury. This appliance is for use with a nominal 120 -volt circuit and has a grounding plug that looks like the plug illustrated in the sketch. The outlet must be properly installed and grounded in compliance with all local codes and ordinances. If it is necessary to use an extension cord, use only a three -wire extension cord that has a three -blade grounding plug and a three -blade grounding plug and a three -slot receptacle that will accept the plug on the appliance. Replace or repair a damaged cord. A B O 00 0 O GROUNDING PIN GROUND -FAULT O INTERRUPTER OUTLET o NEMA 5-15R NOT INCLUDED O OPERATION AND USE INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS. COMPLIANCE WITH LOCAL CODES OR INSPECTIONS IS THE RESPONSIBILITY OF THE PURCHASER AND/OR INSTALLER 1. IMPORTANT! At the end of the day, ALWAYS turn the main power OFF! 2. DANGER: To reduce the risk of injury, do not permit children to use this unit unless they are closely supervised at all times. 3. CAUTION: This unit should not be used by persons with open wounds, cuts or sores on their feet or legs, or by persons with poor circulation, or by persons with heart conditions. If in doubt, the client should consult with his or her physician. 4. Use this unit only for its intended use as described in this manual. Do not use attachments not recommended by the manufacturer 5. Do no operate with a damaged cord or plug. If unit is malfunctions or is damaged in any manner, contact an authorized service representative for examination or repair. 6. Never drop or insert any objects into any opening. 7. Do not block jets during pedicure operation. 8. Water temperature should be checked before use. Water temperature should never exceed 100 degrees Fahrenheit. 9.- Never bring any electrical devices into the unit or operate electrical devices near it. 10. The unit must be connected to a supply circuit that is protected by a ground -fault circuit interrupter (GFCI). 11. Connect the unit only to a properly grounded outlet. See grounding instructions. 12. Close supervision is necessary when the unit is used by, on or near children or invalids. C �Li� cp> 1. water i-iner 3. Back Cushion & Massage 4. Headrest Cushion with Logo 5. Wooden Armrest 6. Manicure Tray 7. Seat Cushion 8. Adjustable Footrest 9. Front Control Panel 10. Jet 11. Drain 12. Jet Control 13. Water Control 14. Hand Spray 15. Drain Control Control Panel [lH5] IDENTIFY YOUR •• 'A SEAT n -I- 11-% w Armrest can be re Reclining SPA [ A 27 - (0) 55" FOOT -SPA CLEARANCE WALL CLEARANCE TYPICAL FOOT -SPAS Center Foal-sp 60" 28" — 'learanc Center K (0) Attaching The Seat to The Base Align the seat wit tightly secure witl (0) :h trays or remote stand to est with screws provided Cleanjet Installation O 4 The Opening .41 Align fingers to the opening, turn counter -clockwise and pull in the arrow direction to remove jet cover Cleanjet Max Components Suction Control Screen (Optional) R • Jet Cover (0) Impeller Plate & Anchors (Cleanjet Max only) Jet Motor & Housing Cleanjet Max Installation Jet Cover and Impeller Anchor (0) Snap the jet cover and impeller onto the anchors located on the plate in the direction of arrow as shown. Make sure the jet snapped securely on the plate. To remove, simply pull the jet cover and impeller from the anchors Cleanjet Max SL Installation r oot� Handle �� Tub Wall Opening ............ ...............: .............. Liner Lock .... Jet r, :z Place the poly liner and drain plug firmly onto the tub, hold the handle and push into the opening located under the footrest in the direction ' of the arrow until it is secured. Make certain that the jet is snapped firmly on the tub wall and the handle is secured to the opening. To remove, simply pull out the handle with jet cover and impeller from the opening Pull out the lock as shown to remove cover and impeller from the handle t , 9 Cleanjet Max Assembly <o� Jet motor components are located behind the tub/bowl wall Q Warnin Disconnect the foot -spa unit from any electrical source before 9 Disassemble the jet unit. All surface must be dry. Some jet Components may contain sharp object and very hot after usage. To remove the jet unit follow the steps below OCarefully detach the Jet Cover and Impeller from Tub Wall © Turn the Cap Head counter -clockwise to remove, carefully pull the metal clamp and the jet motor backward There may be water sealant between the Motor and Tub wall To assemble the jet unit, install in the reverse steps above. You may have to apply some water sealant between the Motor and The Tub wall Under Seat Compartment Tub Wall Motor Cap Head h7 .... o o Aluminum Clamp E2 C Plate located inside the bowl (Cleanjet Max only) Jet Cover & Impeller Jet Handle (Cleanjet Max SL only) apa r Plumbing Connections Gravity Drain Hot & Cold %" Fitting 1 1/4" ABS Pipe P -Trap Not provided (0) 1. Discharge pump may be connected to an existing sink drain or floor drain. It can also pump up to 7 ft high, but this will increase the length of,the drain time. The drain connection is at the rear of the unit by. a 3/4" fitting. 2. Gravity drain uses a standard gravity drain. A floor drain is recommended. Connection via a P -Trap is supplied. 3. Hot and cold water supply connections are located at the rear of the unit ('/2" fittings). Please be advised that the hot and cold water supply lines are not fitted with optional back flow Preventers unless ordered at initial sale. 4. Have a qualified licensed electrician to install the wiring according to local codes. The Cleanjets are 1/10 hp, 120V, 1.2 AMP 600HZ. A 15 amp GFI protected circuit must be used to supply power to the unit. The roller back massage chair uses a 115V supply. 5. Spa base should be anchored securely to the floor. The base may be anchored through the opening in the back of the base wherever access is convenient for the installer. FAILURE TO ANCHOR THE BASE MAY RESULT IN PERSONAL INJURY OR DAMAGE TO THE UNIT. DAMAGE AS A RESULT WILL VOID THE WARRANTY. Jet (On/Off) Control Panel Water Control Hand Spray Drain Control (m) 1. To fill water: The foot -spa is provided with a single hot and cold mixing valve located on the front of your spa(far left). This is a pressure balance valve that requires you to lift the handle to start the water flow and to adjust to the temperature that is desired. The clean jet motor must be completely submerged in water. CAUTION: DO NOT USE FOAMING, SUDSING OR MINERAL OIL BASED ADDITIVES IN THE WATER. 2. To start whirlpool: Press the button as shown. This will start your Clean Jet motor. You may stop the whirlpool function at any time by pressing the button again. 3. The foot -spa is equipped with a hand held sprayer. To activate the hand shower, pull the hand shower from the receptacle and depress the thumb control on the sprayer handle. This will turn on the water. When you release pressure on the thumb control this will turn the water off. 4. To drain whirlpool tub: The spa is equipped with a built in.optional discharge pump. Open the drain plug by turning the control knob as shown. Press discharge pump timer button as shown (pump will run for approx. 2 min.) Average time for drain 1 minute. 9600 & 9700 chairs Shiatsu Roller back massage is equipped with a state of -the -art massage system. The massage system is easy to use; the remote has a one touch power that starts select your own massage. You can also adjust the front to rear position of the chair and the reclining back. By using the remote your client can adjust the back to the most comfortable position. BASIC PRECAUTIONS SHOULD ALWAYS BE OBSERVED, INCLUDING THE FOLLOWING: 1. Read and follow all instructions 2. DANGER. To reduce the risk of injury, do not permit children to use this unit unless they are supervised at all times 3. Use this unit only for its intended use as described in this manual. Do not use attachments that are not recommended by the manufacturer. 4. Never drop or insert any object into any opening. 5. Do not block jets during whirlpool operation. 6. The unit must be connected to an electrical supply circuit that is protected by a ground fault circuit interrupter. 7. The clean jet motor is magnetically driven and is insulated twice. Therefore it does not require to be bonded. Save these instructions 9700 Shiatsu Remote Control Please refer to instruction manual for operations (0) rq Auto Timing Power Neck Back Waist Shoulder Pause Knocking Kneading Kneading Knocking Speed Air On/Off Width AdjusPment intensity Adj stment Recline a Incline Seat Backward Seat Forward ry t % _Y t (0) OPERATIONS & US 5 (®) 9500/9600 Shiatsu Remote Control Please refer to instruction manual for operations Power Timing TT960 \� Upper Knead Fla Knead Body p Flap Neck press Manual Knock Shoulder Back Back Waist � Stretching Q Speed Width [E.EB Seat Seat Seat Backwarc• Incline Recline I (m) Please refer the diagrams to remove jet covers for cleaning Gulfstream Inc. highly recommends the following cleaning regimen. You should always contact your local governing agency for their specific cleaning and disinfecting requirements and regulations for pedicure spas. For your clients safety, always use the regulations as a minimum standard for cleaning and disinfecting. Combining your states standards with the regimen listed below will provide your clients with a safe and healthy pedicure spa environment experience. Routine maintenance: Powdered cleansers or abrasives are NOT RECOMMENDED. A clean towel or sponge, are all that are usually needed. A soft bristled brush may be used when excessive residue is present. Use a mild soap and water solution to clean the upholstery, but do not over wet. Wipe dry with a clean towel. No internal maintenance of the spa components is necessary. Remove clean jet caps and spray with disinfectant after each use. For extra protection, our recommendation is that the system be flushed daily or weekly depending on use. To flush the clean jet system fill spa with hot water to just above the jets. Add disinfectant. Run whirlpool for 15 minutes, drain and then wipe dry with clean soft cloth. NOTE: Cleaning or sanitizing is NOT disinfecting. According to the Centers for Disease Control and Prevention (CDC), and the US Environmental Protection Agency (EPA), disinfecting occurs only when there is a reduction of pathogenic microbes at 99.999%. Sanitizing is only a reduction of 99.9%. Cleaning of whirlpool pedicure spas requires surfactant and chelating detergents that are low -foaming and have the ability to remove body oils, organic oil additives, mineral oil, skin cells, nail clippings etc that can accumulate both in the basin and the jets which may become a fertile area for micro organisms to grow. The use of oil based products can build up in the whirlpool system causing clogging in the jets. Adherence to the above cleaning will minimize build up. Gulfstream does not recommend the use of mineral oil based products. TESTING/FLUSHING FOOT SPA After foot spa has been installed, fill tub with water just above the jets. Carefully check for leaks at drain and over flow. After checking underside for leaks turn on system by pushing whirlpool button and watch for leaks as water circulates. Let tub run full cycle. Open drain plug for water discharge. Gulfstream warrants to the original purchaser that the new pedicure spa will be free from defect during the Standard Warranty Period (listed below). The shipping date and the uniquely -coded Serial Number on the back of each spa chair will justify the start of the warranty period for the product. The warranty is null and void if the pedicure spa is taken from its initial place of installation, or it is not installed in accordance with federal, state or local codes and ordinances. Also, this warranty does not apply if the pedicure spa has been subject to misapplication, improper installation or maintenance, negligence, improper cleaning or other circumstances beyond Gulfstream's control. Warranty 1. Limited Three(3) Years warranty on Spa Shell. 2. Limited One(1) Year warranty on the Whirlpool Pump. 3. Limited One(1) Year warranty on the Clean Jet. 4. Limited One(1) Year warranty on the Glass Bowl. 5. Limited One(1) Year Parts -Only warranty which covers the Hydraulic System, Discharge Pump, Massage System and All Electrical Components. 6. Gulfstream will pay standard shipping charges on all replacement parts during the first 90 days of the stated Warranty Period. After 90 days the consumer is responsible for all labor and shipping costs incurred. Exclusions 1. Damage to pump parts and/or motor parts due to obstruction in plumbing lines etc. 2. Staining, fading or discoloration of plastic surfaces due to exposure and/or the use of harmful cleaning agents or chemicals. 3. Staining, fading or discoloration caused by improper or poor water additives not related to the maintenance of proper water are not covered by this warranty. 4. Staining, fading or, discoloration of the seat, armrests or footrests. 5. Freight damage, misuse, neglect, accident, natural disaster and abuse. 6. Unauthorized repairs. Service 1: The Dealer shall forward all warranty -related matters to our Customer Service Department. 2. Serial Numbers and Original Invoice must accompany all warranty claims. 3. Customers are responsible for shipping defective parts back to Gulfstream. These parts must be packaged correctly in order to protect against any further damage. 4. All parts are to be shipped by UPS Ground Service, average 2-5 days. 5. All defective parts must be shipped back to Gulfstream within 30 days of receiving the new replacement parts or warranty will be void. 6. Any warranty claim that cannot be determined over the phone, the customer must send photos and original invoice directly to Gulfstream before any repairs can be performed. 7. Any service performed on the product without Gulfstreams authorization will also void the Warranty. 8. Each service call from the customer will be assigned a Claim Number. The Claim Number will stay open until the problem is resolved. No dealer or other person has any authority to bind Gulfstream Inc. to changes or additions to this warranty or its products. Accordingly, Gulfstream Inc. Is not responsible for such warranties or representations. rea (lut . • Manufacturer of Acrylic Bath Whirlpool & Pedicure Foot Spas Gulfstream Inc. Cambridge, Ontario, Canada N1R 5X5 Tel.: 519-622-0950 Fax: 519-622-6926 www.gulfstreaminc.com © 2010 All rights reserved. Design and Specifications are subject to change without notice J W61d6-- Y 1® Electric Washer/Dr er PRODUCT MODEL NUMBER LTE6234D Electrical: A 3 or 4 wire, single phase, 120/240 - volt, 60 -Hz., AC -only electrical supply (or 3 or 4 wire, 120/208 -volt electrical supply, if specified on the serial/rating plate) on a separate 30 -amp circuit, fused on both sides of the line must be provided. A time -delay fuse or circuit breaker is recommended. Connect to an individual branch circuit. Do not have a fuse in the neutral or grounding circuit. Exhaust venting: Exhaust your dryer to the outside. Four -inch diameter vent is required. Rigid or flexible metal exhaust vent must be used. Do Not use plastic or metal foil vent. Exhaust outlet hood must be at least 12 inches from the ground or any object that may be in the path of the exhaust. The dryer can be converted to exhaust out right or left side. EXHAUST VENTING Select the route that will provide the straightest and most direct path outdoors. Plan the installation to use the fewest number of elbows and turns. Use the fewest 90' turns possible. Do not use vent runs longer than specified in vent length chart. Determine the number of elbows you will need Recommended hood styles s Angled hood style is acceptable. A 4' (10.2 cm) 4 (102 cm) It 4;-' - (102 cm) N" A. Louvered hood style B. Box hood style Vent Length Chart No. of Type of Vent Box or Angled 90° turns Lowered hoods or elbows minimum 51/2" (14 cm) hoods clearance behind the dryer for 0 Rigid metal 37 ft (11.3 m) 35 ft (10.7 m) Flexible metal 25 it (7.6 m) 20 it (6.1 m) 1 Rigid metal 32 ft (9.7 m) 27 ft (8.2 m) Flexible metal 21 It (6.4 m) 16 ft (4.9 m) 2 Rigid metal 24 It (7.3 m) 19 it (5.8 m) Flexible metal 15 It (4.6 m) 10 It (3.0 m) NOTE: Side exhaust adds a 90° turn inside the washer/dryer. To determine maximum exhaust length, add one 900 turn to the chart. OVERALL DIMENSIONS 71%" (181.9 cm) (81.3 Gi I -Y Otz LkQUI,NfA BUILDING & SAFETY DEPT APPROVED UO NSrRUCTIpN z !� g1/ 233/4" (60.3 cm) -1 (68.6 cm) T 321/4" (81.9 cm) ' Most installations require a minimum 51/2" (14 cm) > clearance behind the dryer for the exhaust vent with elbow. RECESSED AREA AND CLOSET INSTALLATION Additional clearances might be required for wall, door and floor moldings. Rear clearance may be 0° (0 cm) when house exhaust system is lined up directly with dryer exhaust. A 0 0 ... p 0 __..27" 0 0' 1" -H � (0 cm) (68.6cm) (0 cm) (2.5 cm) (81.3 cm) E.- + 6.. i 3.. (15.2 cm) (7.6 cm) 48 in? 310 cm2) 24 in? 155 cm2) 3" (7.6 cm) 51,2.. (14 cm) DRAIN SYSTEM A. Recessed area B. Side view - closet or confined area C. Closet door with vents Standpipe drain system - wall or floor The standpipe drain requires a minimum diameter standpipe of 2" (5 cm). The minimum carry -away capacity can b6 no less than 17 gal. (64 L) per minute. A 2° (5 cm) diameter to 1° (2.5 cm) diameter standpipe adapter kit is available. The top of the standpipe must be at least 39° (99 cm) high and no higher than 96° (2.4 m) from the bottom of the washer. Laundry tub drain system The laundry tub needs a minimum 20 gal. (76 L) capacity. The top of the laundry tub must be at least 34° (86.4 cm) above the floor and no higher than 96° (2.4 m,) from the bottom of the washer. Floor drain system The floor drain system requires a siphon break that may be purchased separately. The siphon break must be a minimum of 28" (71 cm) from the bottom of the washer. Additional hoses might be needed. Because Whirlpool Corporation policy includes a continuous commitment to improve Dimensions are for planning purposes only. For complete details, see Installation Ref. 8577199 our products, we reserve the right to change materials and specifications without notice. Instructions packed with product. Specifications subject to change without notice. y 08-24-05 CERTIFICATE OF COMPLIANCE' (Page 1 of 4) LTG -1C Project Name: Date: CITY NAILS 2 02/16/2010 Project Address:Climate Zone: 15 Building CFA: 78-445 HIGHWAY 111, SUITE 445 LA OUINTA, CA 92253 unconditioned Floor Areo: General Information Building Type: ® Nonresidental ❑ High -Rise Residentol ❑ Hotel/Motel ❑ Schools ❑ Relocatable Public School ® Conditioned Spaces ❑ Unconditioned Spaces Phase of Construction: ❑ New Construction ❑ Addition ® Alternation Method of Compliance: ® Complete Building ❑ Area Category ❑ Tailored Documentation Author's Declaration Statement o I certify that this Certificotion of Complionce documentation is accurate and complete. Name: DU LAM LU Signature: Company: Date: 02/16/2010 Address: If applicable: P.O. BOX 8677 CEA # tt City/State/Zip CEPEPhone: RIVERSIDE, CA 92515 (951) 233-8810 Principal Lighting Designer's Declaration Statement o I am eligible under Division 3 of the Business and Professions Code to accept responsiblilty for the lighting design. o Thi Certificate of Compliance identifies the lighting feotures and performance specifications required for compliance with Title 24, Page 1 and 6 of California Code of Regulations. o The design features represented on this Certificate of Compliance ore consistent with the information provided to document this design on the other applicable compliance forms, worksheets, calculations, plans, and specifications submitted to the enforcement agency for approval with this building permit application. Nome: DU LAM LU � Signature: Company: Phone: (951) 233-8810 Address: License #: P.O. BOX 8677 C 60886 City/State/Zip Date: RIVERSIDE, CA 92515 02/16/2010 Lighting Mandatory Measures ❑ Indicate location on building plans of Mandatory Measures Note Block: LIGHTING COMPLAINCE FORMS d WORKSHEETS (check box if worksheet Is include) For detailed instructions on the use of this and all Enercy Efficiency Standards compliance forms, please refer to the Nonresidential Manual published by the California Energy Commission. ® LTG -1C, Parts 1 through 4 Certificate of Compliance. All Pages required on plans for all submittals. ❑ LTG -2C Lighting Controls Credit Worksheet ® LTC -3C Indoor Lighting Power Allowonce ❑ LTG -4C, Pages 1 through 4 Tailored Method Worksheet ❑ LTG -5C, Pages 1 and 2 Line Voltage Track Lighting Worksheet 2OOB Nenrla/dent/i/ Comp/lance Forme August 2009 ti CERTIFICATE OF COMPLIANCE (Page 2 of 4) LTG -1C INDOOR LIGHTING SCHEDULE AND FIELD INSPECTION ENERGY CHECKLIST Project Name: CITY NAILS 2 Dote: 02/16/2010 Installation Certificate, LTG-I-INST (Retain a co Field Inspector copy and verify form is completed and signed.) ❑ Certificate of Acceptance, LTG -2A (Retain a co Field copy and verify form is completed and signed.) Inspector El A separate Lighting Schedule Must Be Filled Out for Conditioned and Unconditioned Spaces Installed Lighting Power on this Lighting Schedule is only for: ® CONDITIONED SPACE []UNCONDITIONED SPACE ®The actual indoor lighting power listed below includes oil installed permanent and portable lighting systems in accordance with SS146(a) ❑ Only for offices: Up to the first 0.2 watts per square foot of portable lighting shall not be required to be included in the calculation of indoorlighting actual power density in accordance with the Exception SS146(a). All portable lighting in excess of 0.2 watts per square foot is totoed below. to Luminalre Schedule (Type, Lamps, Ballasts Lamps/ Ballasts Installed Watts A B C D E F G H How wattage was Field 2 Inspector determined N N L 7 t O L� C31 L O O �- L N W N O N X p E Complete Luminaire Description ° - N ° CEC According W o m o z } (i.e., 3 lamp fluorescent troffer, F32T8, one dimmable electronic ballast) a) +-E t•- ° Default from to s130 D•- °+ } _ - N a J NAB (d or e) z C 3 a RECESSED DOWNLIGHT ❑ 23 ® ❑ 84 1932 ❑ ❑ C LED EXIT SIGN W/ EMERG. LIGHT COMBO ❑ 24 ® ❑ 5 120 ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ Cl ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ INSTALLED WATTS PAGE TOTAL: 2052 Building total number of pages t Installed Watts Building Total (Sum of all pages) 2052 Enter into LTG -1C Page 4 of 4 1. Wattage shall be determined according to Section 130(d and e). Wattage shall be rating of light fixture, not rating of bulb. 2. If Fail then describe on Page 2 of the Inspection Checklist Form and take appropriate action to correct. Verify building plans if necessary. i ��.... .•v•ooi�an�isi �.ompnence roinl8 August 2009 CERTIFICATE .OF COMPLIANCE (Page 3 of 4) Project Nome: CITY NAILS 2r Date: INDOOR LIGHTING SCHEDULE AND FIELD INSPECTION ENERGY CHECKLIST LTG -1C 02/16/2010 Fill in controls for oil spaces: a) area controls, b) multi-level controls, c) manual daylighting controls for daylit areas > 250 ft2, automatic daylighting controls for daylit areas > 2,500 ft2, d) shut-off controls, e) display lighting controls, f) tailored lighting controls - general lighting controlled separately from display, ornamental accordance with Section 131. and display case lighting and g) demand responsive automatic controls for retail stores > 50,000 ft2, in MANDATORY LIGHTING CONTROLS - FIELD INSPECTION ENERGY CHECKLIST Inspecdtor Type / Description Number of Units Location in Building U) _(D oL u ,a � d o LIGHTING CONTROL PANEL 1 RETAIL SALE AREA ❑ ❑ ❑ OCCUPANCY MOTION SENOR S NEW ROOMS & RESTROOMS ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ O ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ SPECIAL FEATURES INSPECTION CHECKLIST (See Page 2 of 4 of LTG -1C) The local enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification. The local enforcement agency determines the adequacy of the justification, and may reject o building or design that otherwise complies based on the adequacy of the special justification and documentation submitted. Field Inspector's Notes or Discrepancies: ROM Nonrea/dent/s/ Comp//encs Forma August 2009 CERTIFICATE OF COMPLIANCE (Page 4 of 4) LTG -1C Project Name: CITY NAILS 2 Dote: 02/16/2010 Conditioned and Unconditioned space Lighting must not be combined for compliance Indoor Lighting Power for Conditioned Spaces Indoor Lighting Power for Unconditioned Spaces Watts watts Installed Lighting Installed Lighting (from Conditioned LTG -1C Page 2) 2052 (from Unconditioned LTG -1C Page 2) Lighting Control Credit Lighting Control Credit Conditioned Spaces (from LTG -2C) Unconditioned Spaces (from LTG -2C) Adusted Installed Adusted Installed Lighting Power Lighting Power Complies if Installed < Allowed Complies if Installed < Allowed 1 1 Allowed Lighting Power Allowed Lighting Power Conditioned Spaces (from LTG -3C) 3084 Unconditioned Spaces (from LTG -3C) Required Acceptance Test Designer: This form is to be used by the designer and attached to the plans. Listed below is ten acceptance test for the Lighting system, LTG -2A. The designer is requried to check the acceptance tests and list oil control devices serving the building or space shall be certified as meeting teh Acceptance Requirements for Code Compliance. If all the lighting system or control of a certain type requires a test, list the different lighting and the number of systems. The NA7 Section in the Appendix of the Nonresidential Reference Appendices Manual describes the test. Since this will be part of the plans, completion of this section will allow the responsible party to budget for the scope of work appropriately. Forms con be grouped by type of Luminoire controlled. Enforcement Agency: System Acceptance. Before Occupancy Permit is granted for a newly constructed building or space or when ever new lighting system with controi:is installed in the building or space shall be certified as meeting the Acceptance Requirements. The LTG -2A form is not considered a complete form and is not to be accepted by the enforcement agency unless the boxes are checked and/or filled and signed. In addition, a Certification of Acceptance forms shall be submitted to the enforcement agency that certifies plans, specifications, installation certificates, and operating and maintenance information meet the requirement of s10 -103(b) of Title 24 Port 6. The field inspector must receive the properly filled out and signed forms before the building con receives occupancy. A copy of the LTG -2A for each different lighting luminaire control (s) must be provided to the owner of the building for their records. Luminaires Controlled LTG -2A Equipment Requiring Testing Description r I« E—e Z cti LocationElElEl13El 2006 Nonres/dent/s/ Comp//encs Forma August 2009 a ADOOR LIGHTING POWER ALLOWANCE LTG -3C Project Name: CITY NAILS 2 Date: 02/16/2010 ALLOWED LIGHTING POWER (Choose One Method) A separate Lighting LTG -3C must be filled out for Conditioned and Unconditioned Spaces. Indoor Lighting Power Allowances listed on this page are only for: ® CONDITIONED spaces ❑ UNCONDITIONED spaces COMPLETED BUILDING METHOD BUILDING CATEGORY (From146 Table 146=E) WATTS § PER (ft2) X BEAUTY SALON 1,5 TOTALS COMPLETE BLDG. AREA _ ALLOWED WATTS 2056 3084 D E F 2056 3084 AREA WATTS AREA CATEGORY METHOD - Part A A B C D AREA CATEGORY (From § 146 Table 146-F) WATTS X AREA Z _ ALLOWED 2 PER (ft ) (ft ) WATTS Sum of Additonal Allowed Watts from Area Category Method - Part B (from table below) TOTALS AREA WATTS AREA CATEGORY METHOD - Part B Additional Wattage Allowance (from Table 146-F Footnotes) A B C D E F G Primary Additional Wattage Description(s) and Quantity of Special Total ALLOWED Function Sq Ft Watts Per Allowance Luminaire 2Types in each Primary Design WATTS ft2 Allow (B x C) Function Area Watts Smaller of D or F TOTALS - Enter into Area Category Method - Part A (table above) I. Additional watts available only when allowed according to the footnotes on bottom of Table 146-F for chandelier or sconces; art, craft, assembly or manufacturing specialized task work; precision commerical/industrial work; or lab specialized task work, 2. Special luminaries ore light fixtures described in the Table 146-F Footnotes that are subject to an additional wattage allowance. TAILORED METHOD Total Allowed Watts using the Tailored Method token from LTG -4C (Page 1 of 4) Row 3 The indoor lighting power allowance using the Tailored Method of compliance shall be determined using the LTG -4C set of Forms. A separate set of LTG -4C forms sholl be filled out for CONDITIONED and UNCONDITIONED spaces. 20M Nonrooldentlel Comp//encs Forms August 2009