10-1080 (RC)P.O. BOX 1504
78-495 CALL•E TAMPICO
LA QUINTA, CALIFORNIA 92253
Application Number:
10-00001080
Property Address:
78590 HIGHWAY 111
APN:
604 -080 -999 -
Application description:
REMODEL - COMMERCIAL
Property Zoning:
COMMUNITY COMMERCIAL
Application valuation:
100000
T41, �4'e4�Q"
Applicant: Architect or Engineer:
--------------- - -
LICENSED CONTRACTOR'S DECLARATION
BUILDING & SAFETY DEPARTMENT
BUILDING PERMIT
I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with
Section 7000) of Division 3 of the Business and Professionals Code, and my License is in full force and effect.
License Class: B License No.: 769556
�( Date:/I Z Contractor:
• OWNER -BUILDER DECLARATION
I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the
following reason (Sec. 7031 .5, Business and Professions Code: Any city or county that requires a permit to
construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the
permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State
License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or
that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by
any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).:
(_) I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and
the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The
Contractors' State License Law does not apply to an owner of property who builds or improves thereon,
and who does the work himself or herself through his or her own employees, provided that the
improvements are not intended or offered for sale. If, however, the building or improvement is sold within
one year of completion, the owner -builder will have the burden of proving that he or she did not build or
improve for the purpose of sale.).
(_) I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec.
7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of
property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed
pursuant to the Contractors' State License Law.).
(_) I am exempt under Sec. , BAP.C. for this reason
Date:
Owner:
CONSTRUCTION LENDING AGENCY
1 hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the
work for which this permit is issued (Sec. 3097, Civ. C.).
Lender's Name: _
Lender's Address:
LQPERnIIT
VOICE (760) 777-7012
FAX (760) 777-7011
INSPECTIONS (760) 777-7153
Owner:
WASHINGTON ADAM PARTNERSHIP
42620 CAROLINE CT 4102
PALM DESERT, CA 92211 r
Contractor:
KARMAN GENERAL CONTR, JON -
9375 ARCHIBALD AVENUE
RANCHO CUCAMONGA, CA 91730
(909)944-5274
Lic. No.: 769556
Date: 11/23/10
® t 1rs
z
• �;t�� 2 � 2a tib, a
------------------
WORKER'S COMPENSATION DECLARATION
I hereby affirm under penalty of perjury one of the following declarations:
I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided
for by Section 3700 of the Labor Code, for the performance of the work for which this permit is
issued.
I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor
Code, for the performance of the work for which this permit is issued. My workers' compensation
insurance carrier and policy number are:
Carrier SPARTA INS Policy Number 003WK06641
I certify that, in the performance of the work for which this permit is issued, I shall not employ any
person in any manner so as to become subject to the workers' compensation laws of California,
and agree that, if I should become subject to the workers' compensation provisions of Section
700 of the Labor Code, I shall forthwith comply with those provisions.
K Date Q Applicant:
WARNING: FAILURE TO SECURE W RKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL
SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND
DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN
SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES.
APPLICANT ACKNOWLEDGEMENT
IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the
conditions and restrictions set forth on this application.
1 . Each person upon whose behalf this application is made, each person at whose request and for
whose benefit work is performed under or pursuant to any permit issued as a result of this application,
the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City
of La Quinta, its officers, agents and employees for any act or omission related to the work being
performed under or following issuance of this permit.
2. Any permit issued as a result of this application becomes null and void if work is not commenced
within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject
permit to cancellation.
I certify that I have read this application and state that the above information is correct. I agree to comply with all
city and county ordinances and state laws relating to, building construction, and hereby authorize representatives
of this county to nter upon the above-mentioned property for inspection purposes.
Pate: Signature (Applicant or Agent): ^/91
LQPERMIT
„Application Number
. I . . 10-00001080
------ Structure Information
1,580SF TI/VB/B-OCC/34-OL/SPRINKLED -----
Other struct info . .
. . . CODE EDITION
2007/2008
FIRE SPRINKLERS
FULLY
MIXED -USE -OCCUPANCY
B
OCCUPANT LOAD
34.00
----------------------------------------------------------------------------
1ST FLOOR SQUARE FOOTAGE
1580.00
Permit 'BUILDING
PERMIT
Additional desc .
Permit Fee
639.50 Plan Check Fee,.
415.68
Issue Date
Valuation . .
. . 100000
Expiration Date
5/22/11
• Qty Unit Charge
Per
Extension.
BASE FEE
414.50
50.00 4.5000
----------------------------------------------------------------------------
THOU BLDG 50,001-100,000
225.00
Permit . . .
ELECT - ADD/ALT/REM
,Additional desc .
Permit Fee . . . .
57.00 Plan Check Fee
14.25
Issue Date . . . .
Valuation
0
Expiration Date
5/22/11
Qty Unit Charge
Per
Extension
BASE FEE
15.00
20.00 .7500
PER ELEC DEVICE/FIXTURE 1ST 20
15.00
60.00 .4500
-------------------------------------------------=--------------------------
EA ELEC DEVICE/FIXTURE >20
27.00 ,
Permit . . .
MECHANICAL
Additional desc . .
HOOD AND MAKEUP AIR UNITS ONLY
Permit Fee . . . .
43.50 Plan Check Fee
10.88
Issue Date
Valuation . .
. . 0
Expiration Date
5/22/11
Qty Unit Charge
Per
Extension
BASE FEE
15.00
2.00 4.5000
EA MECH VENT INST/ DUCT ALT
9.00
1.00 6.5000
EA MECH EVAP COOLER
6.50.
1.00 6.5000
EA MECH VENT FAN
6.50
1.00 6.5000
----------------------------------------------------------------------------
EA MECH EXHAUST HOOD
6.50
Permit
PLUMBING
Additional desc .
LQPERMIT
Application Number _ 10.00001080
Permit PLUMBING
Permit Fee 1 79.50 -•Plan Check Fee
19.88
Issue Date . . . . Valuation
0
Expiration Date 5/22/11.
Qty Unit Charge Per -
Extension
BASE FEE
15:00
9.00 6.0000 EA PLB FIXTURE
54.00
1.00 7.5000 EA PLB WATER HEATER/VENT
7.50
1.00 3.0000 EA PLB WATER INST/ALT/REP
3.00
-------------------------------------------------------------=--------------
Special Notes and Comments
_
1,580SF TI/B-OCC/34-OL/SPRINKLED [SUBWAY
STORE #48246-01 THIS PERMIT DOES NOT'
INCLUDE ADDITIONAL HVAC EQUIPMENT OR
f
OPTIONAL FEATURES SHOWN ON PLAN.
2007/2008 CALIFORNIA BUILDING CODES.
November 23, 2010 4:56:38 PM AORTEGA.
----------- -------------------------------------
Other Fees . . . . . .- . . ACCESSIBILITY.PLAN REVIEW
41.57
BLDG STDS ADMIN (SB1473)
4.00
ENERGY REVIEW FEE
41.57
Fee,summary. Charged -.,.Paid Credited
Due
•Permit Fee Total 819.50 .00 .00
819.50
Plan.Check Total 460.69 .'00 .00
460.69
Other Fee Total 87.14 .00 .00
87.14
Grand Total 1367.33 .00. .00
1367.33
LQPERMIT
Bin #
�9
G
City of La Quinta
Building 8T Safety Division
P.O. Box 1504, 78-495 Calle Tampico
La Quanta, CA 92253 - (760) 777-7012
Building Permit Application and Tracking Sheet
Permit # _
p
Project Address: ,?S %D b�Aj
Owner's Name: _
A. P. Number: U
,
Address: 15f1U1//- l
Legal Description:
City, ST, Zip:
Contractor: -r b
Address:
Telephone: a f
Project Description: L.V
City, ST, Zip:
&Ai-Z t Utop
Telephone:IFA
� • ;�. ri�,�J
City Lic. #;
State Lic. # :
Arch., Engr., Designer. G
Address:
City., ST, Zip: &A ou." N
OF
Telephone: l 'Z f., y_
.� �7 3 b ,K ` § Construction Type: V-3 Occupancy
State Lic. #: ' ' •:'•� � "`'F`�•"•�<.,r � ��.• Project type,circle one): New Add'n Alter Repair Demo
Name of Contact Person: (EJ/, A Sq. Ft.: %59 # Stories: / # Units:
Telephone # of Contact Person: ZS3 O3
Estimated Value of Project: 06> 0Q()
APPLICANT: DO NOT WRITE BELOW THIS LINE
#
Submittal
Req'd
Recd
TRACMG
PERMIT FEES
Plan Sets
Plan Check submitted 0Item
Amount
Structural Cale&
Reviewed, ready for corrections if
Plan Check Deposit
Truss Calcs.
Called Contact Person
Plan Check Balance,
Title 24 Calcs.
p�
Plans picked up j' Vta
Construction
Flood plain plan
Pians resubmitted
Mechanical
Grading plan
21" Review, ready for correctionsfissuen
Electrical
Subcontactor List
Called Contact Person
Plumbing
Grant Deed
Plans picked up
S.M.I.
H.O.A. Approval
Plans resubmitted
Grading
IN HOUSE:-
Review, ready for correctionstissue If
Developer Impact Fee
Planning Approval
Called Contact Person
A.I.P.P,
Pub. Wks. Appr
Date of permit issue
School Fees
Total Permit Fees
/ol ZD u �f�c �. "f' zK .d1�-�.e- i°/a7 /o/tel -11- Z- /a /Z*re
11 t`�co • 1JS � - s Jkf�P�l�taus f � �ss��
4�6.
rowllArsl,�i�L
PROUDLY SERVING THE
UNINCORPORATED AREAS
OF RIVERSIDE COUNTY
AND THE CITIES OF:
BANNING
BEAUMONT
CALI M ESA
CANYON LAKE
COACHELLA
DESERT HOT SPRINGS
EASTVALE
INDIAN WELLS
INDIO .
LAKE ELSINORE
LA QUINTA
MENIFEE
MORENO VALLEY
PALM DESERT
PERRIS
RANCHO MIRAGE
RUBIDOUx CSD
SAN JACINTO
TEMECULA
WILDOMAR
BOARD OF
SUPERVISORS:
BOB BUSTER
DISTRICT 1
JOHN TAVAGLIONE
DISTRICT 2
JEFF STONE
DISTRICT 3
JOHN BENOIT
DISTRICT 4
MARION ASHLEY
DISTRICT 5
IVERSI'DE Oouwy SIRE-DEPAR'l`11/1imr
IN COOPERATION WITH
THE CALIFORNIA DEPARTMENT OF FORESTRY AND FIRE PROTECTION
77-933 Las Montanas Rd., Ste. #201, Palm Desert, CA 92211-4131 • Phone (760) 863-8886
• Fax(760)863=7072
www.rvcfire.org
Date: November 2, 2010
Case Number: LAQ-I0-TI-041
Project Name: Subway, 78-590 Hwy 1 I 1
Plan Type: Tenant Improvement
You have been issued a release for a tenant improvement on an existing building. THIS IS NOT AN.
OCCUPANCY PERMIT. -
THE FOLLOWING CONDITIONS MUST BE MET PRIOR TO LNSPECTION:
➢ Fire sprinkler system plans for the tenant improvement area must be submitted to the Fire
Department for review, along with a plan/inspection fee. A licensed C-1.6 contractor will have to
submit plans for review and approval and modify the fire sprinkler system in accordance with
NFPA 13, 2002 Edition. A licensed C-16 contractor shall do all sprinkler work and certification.
The approved plans, with Fire Department Job card must be at the job site for all inspections.
➢ Provide keys to the tenant space for inclusion in the main building Knox Box. Key(s) shall have
durable and legible tags affixed for identification of the correlating tenant space.
➢ Shelving, counters, etc., must be in place, however, no merchandise may be placed in the
building prior to .inspection
➢ A minimum 2AIOBC Fire Extinguisher, (State Fire Marshal Approved) must be mounted in a
visible location within 75' walking distance from any point in your building or suite. Fire
extinguishers can be installed by a licensed extinguisher company with a State Fire Marshal
service tag attached to the extinguisher, or purchased from a retail store with a sales receipt
attached. A licensed fire extinguisher company must service extinguisher yearly.
➢ All breakers must be labeled and a clearance of 36 inches must be maintained around the panel at
all times.
Applicant/installer shall be responsible to contact the Fire Department to schedule inspections: A re-
inspection fee will be required if more than one (1) inspection is necessary. Requests for inspections are
to be made at least 72 hours in advance and may be arranged by calling (760) 863-8886.
All questions regarding the meaning of these conditions should be referred to the Fire Department
Planning & Engineering Staff at (760) 863-8886.
ICM
Jason Walsh
Fire Safety Specialist
RIVERSIDE COUNTY COMMUNITY HEALTH AGENCY
DEPARTMENT OF ENVIRONMENTAL HEALTH
FOOD ESTABLISIIMENT PLAN APPROVAL NOTICE
SR# 20723 Date 1.0/25/10
Project Name Subway Address 75890 Highway 111, La Quinta
Plans Submitted by Pedro Garcia Phone 619-253-0340
Owner Don Sowle Address 78664 Como Ct. La Quinta Phone None listed
The plans are now approved subject to the conditions listed below and the attached compliance sheet.
1. Provide a grease interceptor letter from the sewer agency.
2. Page F-2, P2 eggshell finish is not approved, must use semi gloss or gloss paint finish.
3. Page F4, the floor sink.located under.6'e'soda fountain must be half exposed under the soda cabinet,
with the back of the flooc?sirik enclosed with a 3/8" radius cove base.
4. Provide a water heat6r., . ith minimum capacity of 70 gallons with a rating of at least 12.5kW (electric)
or 55000 BTU's (gas).
5: Sneeze guards are to be evaluated during on-site inspections.
CONSTRUCTION INSPECTIONS: Contact the Plan Checker for a Preliminary Inspection when construction is
approximately 80% complete, with plumbing, rough ventilation, and rough equipment installed. Request for inspection should
be made at least five (5) working days in advance.
A FINAL INSPECTION MUST be made upon completion of ALL work including finished details. APPROVAL to operate
shall not be granted, or remodeled areas approved to operate, until the facility has passed the FINAL INSPECTION, and
"APPLICATION TO OPERATE" has been completed and PERMIT FEES have been paid.
Request for inspection should be made at least five (5) working days in advance.
PLANS CHECKED BY Tracey Ford, EHS III Phone (760) 863-8287
I .acknowledge the corrections noted herein and as indicated on the plans and agree to incorporate them during construction:
Signature
Company Name.
DEH -SAN -178 (Rev 2/06)
Date
Corona
Hemet
Indio
Murrieta
2275 S. Main St
800 S. Sanderson
47-950 Arabia St
; 38740 Sky Canyon
Suite 204
(951) 766-2824
"A"
Dr
(951) 273-9140
Fax(951)766-
(760) 863-8287
(951) 461-0284
Fax (951) 520-8319
7874
Fax(760)863-
Fax (95 1) 461-0245
8303
Department Web Site
— www.rivcoeh.org
Palm Springs
554 S. Paseo Dorotea
(760) 3207,1048
Fax (760) 320-1470
Riverside
4065 County
Cir
(951) 358-5172
Fax(951)358-
5017
ax(951)358-
5017
COACHELLA VALLEY WATER DISTRICT ASSESSOR'S PARCEL NUMBER
85-995 Avenue 52
Coachella, California 92236
(760) 399-2651
APPLICATION FOR WASTEWATER INTERCEPTORISEPARATOR APPROVAL
APPLICANT: Submit this form with a copy ora SCALED plot plan (1"= 20' to I"= 4(y SCALE) drawn to District specifications. A nonrefundable filing fee is required
when the application is submitted. Check must be made payable to the Coachella Valley Water District. Approval of this application shall remain valid for a period
not to exceed one (1) year from date of payment.
Plan Check No.
Agent. Contractor, Contact Person
Owner
U 60 W Lf'
Job Propert Add�
y
?8�Y t�r• ,;N;-1
Address
J, City
Legal Description `4
DBA
PLEASE COMPLETE THIS SECTION FOR REVIEW OF FOOD EST,
NOTRe Pr enrcwrr..,.,r... -- _--.
r y.. -o
Zip 76p Telephor
Zip
Z�
- - -- ti arta r� uvry ra wMP4ETE AND THE PLANCHECK
GENERAL CONSTRUCTION: FEE IS PAID.
Type of Construction:7Aernal Seating with Mist + I P r
New Food FacilityAS— Remodel of Exist- g Food Establishment
Ext
ers or Heaters 9m of Operation ting Capacity: internal
Service: �Z External
Bar with Food Service Bar Nonfood Service Water Softener
Multiservice (reusable) Single Service (disposable) L�
OWNER/REPRESENTATIVEDEClARATION:
paid I certify that I have read the entire application and state that all information is correct. I understand that the amount of fee
is based on my declaration of information on this form and that incorrect information is grounds for denial of the submitted plana. I also understand that plans will be
discarded if not picked up within sixty (60) days of approval or denial and that no inspection
Proper information requested has been received and plans have been apved establishment will be conduct
" . �+ or approval granted to operate, until all
Signature �� !.-•• a— �Z
Date
Type of System(s) No. Dwelling Fixture units E3Ssnd/OiI fiqGremw interceptor Waived
[3New ■ [3Grease Interceptor
■Replacement[3Addition ■
■Connect to Sewer I
■
wl
/
Of �,�(( u
Approved ❑Denied ❑Conditional Approval*
'See Remarks
Date
Fee $ - & jj
Check No.
Date
(nidal
CVWD-921
t
P.O. Box 1504
78-495 CALLE TAMPICO
LA OUINTA, CALIFORNIA 92253
To: Greg Butler, Building & Safety Manager
From: Les Johnson, Director -Planning
Permit #:
BUILDING & SAFETY DEPARTMENT
(760) 777-7012
FAX (760).777-7011
To CDD: /0- -90-/0
Due Date: /0 - a7 -%D
Status:, 45-64
Building Plans Approval
(This is an approval to issue a Building Permit)
The Planning Department. has reviewed the Building Plans for the following
project:
o �
Description:
Address or General Location: n
Applicant Contact:. edto. 6/q - a 23 - 0 0#0
The Planning Department finds that:
❑ ...these Building Plans .do not require Planning Department approval.
...these Building Plans are approved by the Planning Department.
❑ ...these Building Plans require corrections. Please forward a copy of the
attached corrections to the applicant. When the corrections are made
please return them to the Planning Department for review.
Les Johnso , Director -Planning
receiveucl
OCT 2 0 2010
City of La Quin,?a
Nanning Departmer+i
to/f,it 0
Date
4
Certificate of Occupancy
Ihaoown� � .
oF�9�. Building & Safety Department
This Certificate is issued pursuant to the requirements of Appendix Chapter 1 Section 110 of the
California Building Code, certifying that, at the time of issuance, this structure was in compliance
with the provisions of the Building Code and the various ordinances of the City regulating
building construction and/or use.
BUILDING ADDRESS: 78-590 HIGHWAY 111
Use classification: COMMERCIAL —SUBWAY RESTAURANT Building Permit No.: 10-1080
Occupancy Group: B Type of Construction:
VB Land Use Zone: CR
Code Edition: 2007/2008 Sprinkler Installed: YES Occupant Load: 34
Owner of Building: WASHINGTON ADAMS PARTNERSHIP
Address: 42-620 CAROLINE CT #102
City, ST, ZIP: PALM DESERT, CA 92211
By: AJ ORTEGA
Building Official Date: JANUARY 5. 2011 ,
' POST IN A CONSPICUOUS PLACE
4
Certificate of Occupancy
Ihaoown� � .
oF�9�. Building & Safety Department
This Certificate is issued pursuant to the requirements of Appendix Chapter 1 Section 110 of the
California Building Code, certifying that, at the time of issuance, this structure was in compliance
with the provisions of the Building Code and the various ordinances of the City regulating
building construction and/or use.
BUILDING ADDRESS: 78-590 HIGHWAY 111
Use classification: COMMERCIAL —SUBWAY RESTAURANT Building Permit No.: 10-1080
Occupancy Group: B Type of Construction:
Riverside County Fire Department Fire Protection Planning Section
' � T
Riverside Office: 2300 Market St., Ste. 150, Riverside, CA 92501 Ph. (951) 955.4777 Fax (951) 955.4886
Murrieta Office: 39493 Los Alamos Rd., Ste A, Murrieta, CA 92563 Ph. (951) 600-6160 Fax (951) 600.6164
+ Palm Desert Office: 77.933 Las Montahas Rd., A 201 Palm Desert, CA 92 21 1-41 31 Ph. (760) 863-8886 (760) 863-7072
Fire Department Clearance/Release
Date: December 29, 2010
To: City of La Quinta Building Dept.
.Fax:
Tract/Parcel Map #:
Permit/Lot #: LAQ-10-TI-041 (Subway)
Job Site Address: 78-590 Hwy 111
Final For Recordation
Release For Building Permit(s)
Shell Final Only (No Tenant)
Approved Final For Occupancy
Building Plan Check Fees Paid
Building Plan Check Fees Not'Paid
Other Fees
Fees Not Required
'If you should have any questions, please contact the appropriate Riverside County Fire Protection
Planning office for further assistance.
Au orizing Signature For Release
Jason Walsh
Print Name
Form C — Revised 12/29/2010
�- BUILDING ENERGY ANALYSIS REPORT
PROJECT:
Subway 48246-0
78590 H ig hway 111
La Quinta, CA 92253
Project Designer:
G Design
Report Prepared by:
Michael Dell
DELL CO.
1629 York Drive
Vista, Ca 92084
760-940-0064
RECEIV1FI:)
OCT 20 2010
BY. CITY OF LA QUINTA
Job Number: BUILDING & SAFETY DEPT.
APPROVED
nr10-1410m FOR CONSTRUCTION
Date: DATE BY
10/14/2010
The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is
authorized by the California Energy Commission for use with both the Residential and Nonresidential 2008 Building Energy Efficiency Standards.
This program developed by EnergySoft, LLC — www.energysoft.com.
EnergyRo 5.1 by Ener Soft User Number: 1712 RunCode: 2010-10.14719:56:19 /D: nr10-1410m
J.,;r4 {i1QUlMD Cr.AQjUWq {3X EUQtaaGjj' -,,-C - //1` A"611g1� �4G1: CQ;Si'
T n(jjo,.'-iq Na 1pof 4. (OtUIJ cmd) C'-'ll;w;2,eou (JL MO : rp qow (Na Lqc—m3UUPVI VIA SOOa RMAll%6 E0901A F;(i(_
IV Fui:lb :6to r wbr.(El b,,Odi!'W P5a POW Urq 10 bullnuu CII Mcnipow 2'auu;7Us- w ccWbyfjcN E1.7CU ,11'2 b14Qt9Ll iin Jt1'nrl/:'l 7.:q f?
J 01.1141504 0
!ALJ 0-J,4•1 ULU Lois come.Lunc-Ltoo
`l 1 i4 i; �e� •
neo-aqo-ooel
Mfg' 09 a5O9.4•
J P.',Sa AOLK D1.1 AS
DErf- CO"
Al!('PS-1 Dbli
blbbOLI bLrbaLcq ph:
1
C p%--elau
bLOISCI Us2liUUGL:
rs -onmo, c4' a5sn
inn H!aPMSA J J J
bUOIECI:
TABLE OF CONTENTS
Cover Page
Table of Contents
Form LTG -1-C Certificate of Compliance
Form LTG -3-C Indoor Lighting Power Allowance
Form LTG -MM Lighting Mandatory Measures
EnergyPro 5.1 by EnergySoft Job Number. ID• nr10-1410m User Number. 1712
1
2
3
7
8
CERTIFICATE OF COMPLIANCE Part 1 of 4) LTG -1 C
Project Name
Date
Subway 48246-0
10/14/2010
Project Address
Climate Zone
Total Cond. Floor Area
Unconditioned Floor Area
78590 Highway 111 La Quinta
15
1,580
0
GENERAL INFORMATION
Building Type: m Nonresidential ❑ High -Rise Residential ❑ HoteVMotel Guest Room
❑ School ❑ Relocatable Public m Conditioned Spaces ❑ Unconditioned Spaces
School
Phase of Construction: ❑ New Construction ❑ Addition m Alteration
Method of Compliance: ❑ Complete Building m Area Category ❑ Tailored
Documentation Author's Declaration Statement
I certify that this Certificate of Compliance documentation is accurate and complete.
Signature
Name
Michael Dell
Date
Company
DELL CO.
10/1412010
Address
CEA #
1629 York Drive
CEPE # NR08-90-3530
City/State2ip
Phone
Vista, Ca 92084
760-940-0064
The Principal Lighting Designer's Declaration Statement
• I am eligible under Division 3 of the California Business and Professional Code to accept responsibility for the
lighting design.
• This Certificate of Compliance identifies the lighting features and performance specifications required for
compliance with Title 24, Pages 1 and 6 of the California Code of Regulations.
• The design features represented on this Certificate of Compliance are consistent with the information provided
to document this design on the other applicable compliance forms, worksheets, calculations, plans and
specifications submitted to the enforcement agency for approval with this building permit application.
Name
Signature
Pedro Garcia
Company
Phone
G Design
Address
License #
City/State/Zip
Date
Lighting Mandatory Measures
Indicate location on building plans of Mandatory Measures Note Block:
LIGHTING COMPLIANCE FORMS & WORKSHEETS check box if worksheets is Included
For detailed instructions on the use of this and all Energy Efficiency Standards compliance forms; please refer to the Nonresidential Manual published
by the California Energy Commission.
m LTG -1 C Pages 1 through 4 Certificate of Compliance. All Pages required on plans for all submittals.
m LTG -2C Lighting Controls Credit Worksheet
0 LTG -3C Indoor Lighting Power Allowance
❑ LTG -4C Pages 1 through 4 Tailored Method Worksheet
❑ LTG -5C Pages 1 and 2 Line Voltage Track Lighting Worksheet
EnergyPro 5.1 by EnergySoftUser Number: 1712 RunCode: 2010-10-14719:56:19 ID: nr10-1410m Page 3 of 8
CERTIFICATE OF COMPLIANCE Part 2 of 4) LTG -1 C
Project Name
Subway 48246-0
Date
11011412010
INDOOR LIGHTING SCHEDULE and FIELD INSPECTION ENERGY CHECKLIST
Installation Certificate, LTG -1- INST (Retain a copy and verify form is completed and signed.)
Field Inspector ❑
Certificate of Acceptance, LTG -2A Retain a copy and verity form is completed and signed.)
Field Inspector ❑
A separate Lighting Schedule Must Be Filled Out for Conditioned and Unconditioned Spaces Installed Lighting Power listed on
this Liahtinq Schedule is only for:
® CONDITIONED SPACE ❑ UNCONDITIONED SPACE
® The actual indoor lighting power listed below includes all installed permanent and portable lighting systems in accordance
with §146(a).
Only for offices: Up to the first 0.2 watts per square foot of portable lighting shall not be required to be included in the
® calculation of actual indoor lighting power density in accordance with the Exception to §146(a). All portable lighting in excess of
0.2 watts per square foot is totaled below.
Luminaire (Type, Lams Ballasts
Installed Watts
A
B
C
D
E
F
G
H
None
or
Item
Ta
Complete Luminaire Description'
(Le, 3 lamp fluorescent troffer,
F32T8, one dimmable electronic ballasts
m
3
li
a
m m
a
;
-J
How wattage
Was determined
2 2
(D Cd
E E
> >
Z
�
X
C3
m
42
`0
3:a
Field
Ins actor'
CEC
Default
From
NA8
d
c
E-
o �
8 o
¢ F-
H
m m
u.
A
(2) 4 ft Fluorescent T8
❑
62.0
®
1 ❑
2
124
❑ ❑
8
2 ft PL -40W L
❑
45.0
®
❑
9
405
❑ ❑
C
2 ft PL -40W L
❑
45.0
®
❑
3
135
❑ ❑
D
(1) 45w D
❑
49.0
®
❑
5
245
❑ ❑
G
(2) 4 ft Fluorescent T8 Rapid Start
❑
70.0
®
❑
7
490
❑ ❑
P
P 15w MAXLIGHT MLS15
❑
16.0
®
❑
9
144
❑ ❑
❑
❑
❑
❑ ❑
❑
❑
❑
❑ ❑
❑
❑
❑
❑ [313
11
1:10
❑
❑
❑
❑
❑ ❑
❑
❑
❑
❑ ❑
❑
❑
❑
❑ ❑
❑
❑
❑
❑ ❑
❑
❑
❑
❑ ❑
❑
❑
❑
❑ ❑
❑
❑
❑
❑ ❑
❑
❑
❑
❑ ❑
Installed Watts Page Total:
11543
Building total number of pages:
Installed Watts Building Total
Sum of alla es
1,543
Enter into LTG -1C Page 4 of 4
1. Wattage shall be determined according to Section 130 (d and e). Wattage shall be rating of light fixture, not rating of bulb.
2 . If Fail then describe on Page 2 of the Inspection Checklist Form and take appropriate action to correct. Verify building plans if necessary.
Ener Pro 5.1 by Ener Soft User Number: 1712 RunCode: 2010-10-14719:56:19 ID: nr10-1410m Page 4 of 8
CERTIFICATE OF COMPLIANCE Part 3 of 4
LTG-1C
Project Name
Subway 48246-0
Date
10/14/2010
INDOOR LIGHTING SCHEDULE and FIELD INSPECTION ENERGY CHECKLIST
Fill in controls for all spaces: a) area controls, b) multi-level controls, c) manual daylighting controls for daylit areas > 250 ftz,
automatic daylighting controls for daylit areas > 2,500 ftp, d) shut-off controls, e) display lighting controls, f) tailored lighting controls —
general lighting controlled separately from display, ornamental and display case lighting and g) demand responsive automatic
controls for retail stores > 50,000 ftz, in accordance with Section 131.
MANDATORY LIGHTING CONTROLS — FIELD INSPECTION ENERGY CHECKLIST
Field
Ins for
Number Special
Type/ Description of Units Location in Building Features
Pass
Fail
Auto Time Switch T.I. ❑
❑
❑
❑
❑
❑
❑
❑
❑
❑
❑
❑
❑
❑
❑
❑
❑
❑
❑
❑
❑
❑
❑
❑
❑
❑
❑
❑
❑
❑
❑
❑
❑
❑
❑
❑
❑
❑
❑
❑
❑
❑
❑
❑
❑
❑
❑
❑
❑
❑
❑
❑
❑
❑
❑
❑ 1
❑
❑
❑
❑
❑
.❑
❑
❑
❑
❑
SPECIAL FEATURES INSPECTION CHECKLIST See Page 2 of 4 of LTG-1C
The local enforcement agency should pay special attention to the items specified in this checklist. These items require special written
justification and documentation, and special verification. The local enforcement agency determines the adequacy of the justification,
and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation
submitted.
Field Inspector's Notes or Discrepancies:
Ener Pro 5.1 by Ener Soft User Number: 1712 RunCode: 2010-10-14719:56:19 ID: nr10-1410m
Pae 5 of 8
CERTIFICATE OF COMPLIANCE Part 4 of 4 LTG -1 C
Project Name
Date
Subway 48246-0
10/14/2010
CONDITIONED AND UNCONDITIONED SPACE LIGHTING MUST
NOT BE COMBINED FOR COMPLIANCE
Indoor Lighting Power for Conditioned S ces
Indoor Lighting Power for Unconditioned S ces
Watts
Watts
Installed Lighting
1,543
Installed Lighting
0
from Conditioned LTG -1 C, Page 2
from Unconditioned LTG -1 C, Page 2
Lighting Control Credit _
0
Lighting Control Credit _
0
Conditioned Spaces from LTG -2C
Unconditioned Spaces from LTG -2C
Adjusted Installed
1 543
Adjusted Installed =
0
Lighting Power
Lighting Power
Complies if Installed 5 Allowed
Complies if Installed:5 Allowed
Allowed Lighting Power
Allowed Lighting Power
Conditioned Spaces from LTG -3C or PERF -1
2,074
Unconditioned Spaces from LTG -3C)0
Required Acceptance Tests
Designer:
This form is to be used by the designer and attached to the plans. Listed below is the acceptance test for the Lighting system,
LTG -2A. The designer is required to check the acceptance tests and list all control devices serving the building or space shall be
certified as meeting the Acceptance Requirements for Code Compliance. If all the lighting system or control of a certain type requires
a test, list the different lighting and the number of systems. The NA7 Section in the Appendix of the Nonresidential Reference
Appendices Manual describes the test. Since this form will be part of the plans, completion of this section will allow the responsible
party to budget for the scope of work appropriately. Forms can be grouped by type of Luminaire controlled.
Enforcement Agency:
Systems Acceptance. Before Occupancy Permit is granted for a newly constructed building or space or when ever new lighting
system with controls is installed in the building or space shall be certified as meeting the Acceptance Requirements.
The LTG -2A form is not considered a complete form and is not to be accepted by the enforcement agency unless the boxes are
checked and/or filled and signed. In addition, a Certificate of Acceptance forms shall be submitted to the enforcement agency that
certifies plans, specifications, installation certificates, and operating and maintenance information meet the requirements of
§10-103(b) of Title 24 Part 6. The field inspector must receive the properly filled out and signed forms before the building can receive
final occupancy. A copy of the LTG -2A for each different lighting luminaire control(s) must be provided to the owner of the building
for their records.
Controls for Credits
LTG -2A
Controls and
Sensors and
Automatic
Number of
Daylighting
Luminaire
Controls
Equipment Re uirin Testing
Description controls
Location
Acceptance
13
13
13
13
13
13
❑
13
Ener Pro 5.1 by Ener Soft User Number: 1712 RunCode: 2010-10-14T19:56:19 ID.- nr10-1410m Pae 6 of 8
INDOOR LIGHTING POWER ALLOWANCE LTG-3C'
Project Name
Subway 48246-0
Date
10/14/2010
ALLOWED LIGHTING POWER Chose One Method
A Separate LTG-3C must be filled out for Conditioned and Unconditioned Spaces. Indoor Lighting Power Allowances listed on this
page are only for:
0 CONDITIONED SPACES ❑ UNCONDITIONED SPACES
COMPLETE BUILDING METHOD
BUILDING CATEGORY From §146 Table 146-E
WATTS
PER (fe) X
TOTALS
COMPLETE
BLDG. AREA
=
ALLOWED
WATTS
AREA
WATTS
AREA CATEGORY METHOD
BUILDING CATEGORY From §146 Table 146-F
WATTS
PER (ft2)
X
Area ft2
=
ALLOWED
WATTS
Dining
1.10
659
725
Kitchen, Food Preparation
1.60
796
1,274
Con'idor/Restroom/Support
0.60
125
75
TOTALS
1,580
2,074
AREA
WATTS
TAILORED METHOD
Total Allowed Watts using the Tailored Method taken from LTG-4C Pae 1 of 4 Row 3
0
The indoor lighting power allowance using the Tailored Method of compliance shall be determined using the LTG-4C set of forms. A separate set of LTG-
4C forms shall be filled out for CONDITIONED and UNCONDITIONED spaces
EnergyPro 5.1 by Ener Soft User Number: 1712 RunCode: 2010.10-14T19:56:19 ID: nr10-1410m Pae 7 of 8
LIGHTING MANDATORY MEASURES: NONRESIDENTIAL LTG -MM
Project Name
Date
Subway 48246-0
10/14/2010
Indoor Lighting
Measures:
§131(d): Shut-off Controls
For every floor, all interior lighting systems shall be equipped with a separate automatic control to shut off the lighting.
1.
This automatic control shall meet the requirements of Section 119 and may be an occupancy sensor, automatic time
switch or other device capable of automatically shutting off the lighting.
2
Override for Building Lighting Shut-off: The automatic building shut-off system is provided with a manual, accessible
override switch in sight of the lights. The area of override is not to exceed 5,000 square feet.
§119(h):
Automatic Control Devices Certified: All automatic control devices specified are certified, all alternate equipment shall
be certified and installed as directed by the manufacturer.
§111:
Fluorescent Ballast and Luminaires Certified: All fluorescent fixtures specified for the project are certified and listed in the
Directory. All installed fixtures shall be certified.
§131(a):
Individual Room/Area Controls: Each room and area in this building is equipped with a separate switch or occupancy
sensor device for each area with floor -to -ceiling walls.
Uniform Reduction for Individual Rooms: All rooms and areas greater than 100 square feet and more than 0.8 watts
§131(b):
per square foot of lighting load shall be controlled with bi-level switching for uniform reduction of lighting within the
room.
Daylight Area Control: All rooms with windows and skylights that are greater than 250 square feet and that allow for
§131(c):
the effective use of daylight in the area shall have 50% of the lamps in each daylit area controlled by a separate switch;
or the effective use of daylight cannot be accomplished because the windows are continuously shaded by a building on
the adjacent lot. Diagram of shading during different times of the year is included on plans.
§131(c):
Display Lighting. Display lighting shall be separately switched on circuits that are 20 amps or less.6.
Outdoor Lighting Measures:
§130(c)1:
Mandatory lighting power determination for medium base sockets without permanently installed ballasts
§132(a):
All permanently installed luminaires with lamps rated over 100 Watts either have a lamp efficacy of at least 60 lumens
per Watt or are controlled by a motion sensor.
§132(b):
All Luminaires with lamps rated greater than 175 Watts in hardscape area, including parking lots, building entrances,
canopies, and all outdoor sales areas meet the Cutoff Requirements.
§132(c)1:
All permanently installed outdoor lighting meets the control requirements listed.
§132(c):
Building facades, parking lots, garages, canopies, and outdoor sales areas meet the Multi -Level Lighting Requirements
listed.
Ener Pro 5.1 by