Loading...
0301-215 (ELEC)LICENSED CONTRACTOR DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professionals Code, and my License is. in full force and effect. License # Lic. Class Exp. Date 763401 C-45 0,51,31/2r, /2r, Date !?'y' !'' Signature of Contractor OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractor's License Law for the following reason: ( ) I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec. 7044, Business & Professionals Code). ( ) I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business & Professionals Code). ( ) I am exempt under Section , B&P.C. for this reason Date Signature of Owner _WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: ( ) I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. ( ) I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier & policy no. are: Carrier Policy No. (This section need not be completed if the permit valuation is for $100.00 or less). ,",,,(r)' I certify that in the performance of the work for which this permit is issued, 1 shall not employ'any person in any manner so as to become subject to the workers' compensation laws of California, and agree -that if I should become subject to the workers' compensation ,provisions of�Section 3700 of the Labor Code, I shall forthwith comply with those provisions:• ,.^Date: 11/1 �1.' Applicant �„• w ”. i Warning: Failure to secure Workers' Compensation coverage is unlawful and shall subject an employer to criminal penalties and civil fines up to $100,000, in addition to the cost of compensation, damages as provided for in Section 3706 of the Labor Code, interest and attorney's fees. . - IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the conditions and restrictions set forth on his application. 1. Each person upon whose behalf this application is made & each personlat, whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this applicaton agrees to, & shall, indemnify & hold harmless the City of La Quinta, its officers, agents and employees. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is correct. I agree to comply with all City, and State laws relating to the building construction, and hereby authorize representatives of this City to enter upon the above-mentioned property for inspection purposes. ,—'Signature (Owner/Agent) '�^ — Date BU40ILDING PERMIT PERMIT# ° 0301-2-16 DATE ��egLraSVs,VALUATION LOT TRACT JOB SITE APN ADDRESS OWNER CONTRACTOR / DESIGNER / EN (NEER TOM & C-01WIE, tl+ ORKMJrAR 'SOP O7.' TIME SKIM LA Q'id11'4TA% CA 92253 (160)341-8224 MVI 5799 USE OF PERMIT 2 lVi°ZR14A1,L'Y 1L1,LC1YA1W.AT D C. -#ANT ZL LETTERED SIGN PxR sig VALUATION ?,SDU,Rl3 Ls r � '3T 4Z�QA 3 Con ov, ck"Jwts' 1wanow 34500/60 EUMC `RIC L RU 7 Ol �,,100m42.0-000 $30.00 /� 1 {�,. Yry�rv���•�{�/q�yN j� �,•�• CHECK O V'W7.fi�.a'4rYX! AND MAN �a`I'4 •.�.I4.K ^�,�yp��j (j I $ 0.00 lac JAN 14 2003 TO�� FliMOTMRS JYr,X:K0 CITY OF L4 QUIN TA FINANCE DEPT. t/ RECEIPT DATE t: BY DATE NAL INSP TOR c 1. INSPECTION RECORD OPERATION DATE INSPECTOR OPERATION DATE INSPECTOR BUILDING APPROVALS MECHANICAL APPROVALS Set Backs Underground Ducts Forms & Footings Ducts Slab Grade Return Air Steel Combustion Air Roof Deck Exhaust Fans O.K. to Wrap F.A.U. Framing Compressor Insulation Vents Fireplace P.L. Grills Fireplace T.O. Fans & Controls Party Wali Insulation Condensate Lines Party Wall Firewall Exterior Lath t Drywall - Int. Lath Final Final_ BLOCKWALL APPROVALS POOLS - SPAS Steel Set Backs Electric Bond Footings Main Drain Bond Beam Approval to Cover Equipment Location Underground Electric Underground Plbg. Test Final Gas Piping PLUMBING APPROVALS Gas Test Electric Final Waste Lines Heater Final Nater Piping Plumbing Final "Plumbing Top Out Equipment Enclosure Shower Pans O.K. for Finish Plaster Sewer Lateral Pool Cover Sewer Connection Encapsulation Gas Piping Gas Test Appliances Final Final Utility Notice (Gas) ELECTRICAL APPROVALS Temp. Power Pole Underground Conduit Rough Wiring Lave Voltage Wiring Fixtures Main Service Sub Panels Exterior Receptacles G.F.I. Smoke Detectors Temp. Use of Power Final Utility Notice (Perm) COMMENTS:I I�t/yf�!✓ 7 Designed extlus' or: coioti - REA (�51� AS Miss CO. S; GIms Curves, P of THE Ll I Sign Details IGN DATE 76o341.81924 4-882 JON/ OR. PALM DESERT, CA 92260 ERIC MFRTBN j Fax 341.0580 THIS DESIGN IS THE EXCLUSIVE PROPERTY RIGHT OF TOP OF THE LINE SIGNS. ALL STANDARD COPY RIGHT LAWS WILL BE ENFORCED. Listed sign section. NEC 600.3. Depth Consists of insulating boots, — ► varies insulating sleeves, plastic face, :ubs supports and channel letter. suitable for damp, wet orpputdoor locations unless m6ked for dry or indoor locations only ---� Tube support Neon tube. ----- Spaclngs maintained per spacing table. Plastic face -- Electrode insulating Otter Boot, GM insulating 819M sleeve provided'. srles with sign. Conduit loclmut %picalI Fasteners as required by the local jurisdiction. Primary electrical source NEC 6005. Listed disoonned swot h M primary to 1 — be within sight (maximum 5011.) of sign. (Many interpret transformer enclosure to be part of sign.) NEC 110-3(b), 600.6. Listed flex (metal show) and listed GTO cable (secondary side only). See dwg C6 and C7 for dotal requirroments. For nonmeWlilc see dwg CBA and C7A. SpackW maintained per spacing table. SPACING TABLE A Between insulated high voltage wiring and 1) primary wiring and2) dead ' metal where dead metal is parallels 1 he high vonage wiring f or mom than length. 8. Between Aeon tubing and nearest surface. C. Between l nhwlafedhighvoltage pans and1)dead metaland2)insulatl higthvoltageorsu pplylconduaors. 0. Between uninsulatedhighvollagepartsand1)other uninsulatedhigh vdWgepartsvW2) w*mlatedsuppfyandbwvonageparts. Voltage A 8 C D 1001 to 5000 Minch Winch Which t irtch 5001 to 10000 3/4 in Winch 1.118inch 1-112hich 10001 to 15000 1 itich 1/4 Inch 1 -NP inch 2indn Listed sign section (consists of transformer and enclosure) suable for damp. wet or Outdoor locations unless marked for dry or indoor locations only. Accessible.. f 1 NEC 6043, 600.5(c)(1)(2), 800.7, 600.8, 600-8(d), 600.21 d 600.23. Grounded endosure. S r 1 v �--- Fasteners as required by iota! jurisdiction. Drain holes iF used in damp, �7 wet or outdoor locations. Wali varies In 00clotess " ♦—`♦ Seal txaldhtg penetration(s) to comply and material with applicable building code requirements. tvt 10 marks: _ istkhg marc sign section label shag e on each letter and transtonner act sure. he fast blank space identifies the umber of each sign section. The econd blank space irdieales he total number of sign sections. LUSTED by Qualified electrical testing laboratory ELECTRIC SIGN SECTION NO. XX -123456 of [_� 1 Installation of signs listed per UL48 Note: Installation requirements only. Manufacturing requirements contained in UL48. A11*19 assivILLUMINATED CHANNEL LETTER revro&=W or cure it any bm of br any I • g 40k, awevonic. Of Me"Ailbu, INSULATING BOOT AND SLEEVE OMW* . few". W% of Wornlab" agape and raw" sr.*= -.�ilhoutweieer+vemr's.ionotnrea+bN>fMcesetgRlral+i+pleoopi�aiel�vidrWj _._ ._ _._ _ _ ... pages meg be made by a bwa Ode ehelrkyl air 049a4tlon firm for I* am pod" Date: April 1996 ot pwA ft guidance on ore insreaation of e(eebicat s" or outs e ! ifsrlp, WW40 _. _. _. . �ar"� ''bnofo1epw)ww Scale IAEI T UL48-T10 1 , None Dwo. No. TITLE 24 REPORT Title 24 Report for: Curves Diet Center 78-595 Hwy 111 Suite 150 La Quinta, Ca 92234 5 Project Designer: Bob Sipovac Jr 72651 Theodora Ln Palm Desert, Ca. 92260 567-2347 Report Prepared By: Bob Sipovac Jr. Sipovac Construction 72651 Theodora Lane Palm Desert, CA 92260 (760) 779-0790 CITY OF LA QUINTA Job Number: BUILDING & SAFETY DEPT. 062003 FOR APPROVED CONSTRUCTION GATE S�y ? BY ��� Date: 2/12/2003 The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2001 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC (415) 883-5900. EnergyPro 3.1 By EnergySoft Job Number: 062003 User Number: 5289 i - t TABLE OF CONTENTS I Cover Page 1 Table of Contents 2 Form LTG -1 Certificate of Compliance 3 Form LTG -2 Lighting Compliance Summary 6 Form LTG -3 Lighting Controls Credit Worksheet 7 Form LTG -MM Lighting Mandatory Measures 8 Form MECH-1 Certificate of Compliance 9 Form MECH-2 Mechanical Equipment Summary 11 Form MECH-3 Mechanical Ventilation 13 Form MECH-4 Mechanical Sizing and Fan Power 14 Form MECH-MM Mechanical Mandatory Measures 15 t i a a A i EnergyPro 3.1 By EnergySoft Job Number: 062003 User Number: 5289 CERTIFICATE OF COMPLIANCE Part 1 of 3 LTG -1 PROJECT NAME DATE Curves Diet Center 2/12/2003 PROJECT ADDRESS 78-595 Hwy 111 Suite 150 La Quinta PRINCIPAL DESIGNER - LIGHTING TELEPHONE Building Permit # DOCUMENTATION AUTHOR Sipovac Construction TELEPHONE (760) 779-0790 Checked by/Date Enforcement A enc Use GENERAL INFORMATION DATE OF PLANS BUILDING CONDITIONED FLOOR AREA CLIMATE ZONE 01 /25/2003 1,207 sq.Fc. 15 BUILDING TYPE NONRESIDENTIAL n HIGH RISE RESIDENTIAL n HOTEL/MOTEL GUEST ROOM PHASE OF CONSTRUCTION NEW CONSTRUCTION ADDITION 0 ALTERATION EXISTING + ADDITION METHOD OF LIGHTING COMPLETE BUILDING ® AREA CATEGORY [—] TAILORED PERFORMANCE COMPLIANCE STATEMENT OF COMPLIANCE This Certificate of Compliance lists the building features and performance specifications needed to comply with Title 24, Rarts1 and 6 of the California Code of Regulations. This certificate applies only to building lighting requirements. The documentation preparer hereby certifies that the documentation is accurate and complete. DOCUMENTATION AUTHOR SIGN DATE Bob Si ovac Jr. z z v The Principal Lighting Designer hereby certifies that the proposed building design re esented in this et of construction documents is consistent with the other compliance forms and worksheets, with the specifications, and with any other calculations submitted with this permit application. The proposed building has been designed to meet the lighting requirements contained in Sections 110, 119, 130 through 132, and 146 or 149 of Title 24, Part 6. Please check one: ❑ I hereby affirm that I am eligible under the provisions of Division 3 of the Business and Professions Code to sign this document as the person responsible for its preparation; and that I am licensed in the State of California as a civil engineer or electrical engineer, or I am a licensed architect. I affirm that I am eligible under the provisions of Division 3 of the Business and Professions Code by Section 5537.2 or 6737.3 to sign this document as the person responsible for its preparation; and that I am a licensed contractor performing this work. ❑ I affirm that 1 am eligible under the exemption to Division 3 of the Business and Professions Code to sign this document because it pertains to a structure or type of work described as exempt pursuant to Business and Professions Code Sections 5537, 5538 and 6737,1, PRINCIPAL LIGHTING DESIGNER - NAME SIGNATURE DATE LIC. # LIGHTING MANDATORY MEASURES Indicate location on plans of Note Block for Mandatory Measures INSTRUCTIONS TO APPLICANT For detailed instructions on the use of this and all Energy Efficiency Standards compliance forms, please refer tot e Nonresidential Manual published by the California Energy Commission. LTG -1: Required on plans for all submittals. Part 2 and 3 may be incorporated in schedules on plans. LTG -2: Required on all submittals. LTG -3: Optional. Use only if lighting control credits are taken. LTG -A: Or, o_nal. Use only if Tailored method is used. LTG 5: Optional. Use only if Tailored method is used. EnergyPro 3.1 By EnergySoft . User Number 5289 Job Number: 062003 Page:3 of 16 LIGHTING COMPLIANCE SUMMARY Part 2 of 3 LTG -1 PROJECT NAME DATE Curves Diet Center 2/12/2003 INSTALLED LIGHTING SCHEDULE I eMac I Rei i ACTS II Luminaire Code LUMINAIRE DESCRIPTION TYPE SCRiPTiON # Wafts . Pa... Lamp --- - - .. DESCRIPTION # Lam +Ballast Total Watts # I Watts 2 4 ft Fluorescent T8 Elec F32T8 2 32 Electronic 1.0 10 62.0 620 II(�I�J Lighting Schedule on Plans Shows Extortor Lighting Subtotal from this Page 620 Meets Total 620 ❑ Efficacy and Control Requirement of fI30(c) Portable Lighting (From LTG -1) �0 Control Requirements of 6131Less Control* Credit Watts (From LTG -31 � .. ❑(f) 310 Adjusted Actual Watts MANDATORY AUTOMATIC CONTROLS CONTROL LOCATION CONTROL CONTROL TYPE NOTE TO (Room #) IDENTIFICATION (Auto Time Switch, Exterior, etc.) SPACE CONTROLLED FIELD CONTROL LOCATION (Room # or Dwg. #) Diet Center CONTROL CONTROLTYPE IDENTIFICATION (Occupant, Daylight, Dimmi -50% 10 NOTE TO NOTES TO FIELD - For Buildina Department Use Only EnergyPro 3.1 By Energysoft User Number: 5289 Job Number: 062003 Page:4 of 16 _IGHTING COMPLIANCE SUMMARY Part 3 of 3 LTG -1 PROJECT NAME DATE _Curves Diet Center 2/12/2003 RQQM # 99FAULT AR€A TOTAL WATT§ OR ZONE ID W/s ft SF B X C TOTAL 0 0 ]TABLE I B- PORTABLE LIGHTING SHOWN ON PLANS FOR OFFICE AREAS> 50 SQUARE FEET FA] a o a o a a LUMIN. TASK # OF TOTAL TOTAL ROOM # _ PORTABLE LIGHTING # OF WATTS PER AREA TASK AREA (SF) WATTS TABLE 1C - PLANS SHOW PORTABLE LIGHTING IS NOT REQUIRED FOR OFFICE AREAS > 250 SQUARE FEET ROOM # -OR ZME 1u TOTAL AREA W iresigner neeris co jiravitfre tieiczri�eti titicurtieiniaocion Yi ati cne iiyfiiYi ng' level provided by the overhead lighting meets the needs of the space. The details Include luminaire types, CU, and mounting locations relative to work areas. TOTAL 0 BUILDING SUMMARY - PORTABLE LIGHTING BUILDING SUMMARY TOTAL AREA (SF) (FROM TABLES 1A+1B+1C) TOTAL WATTS (FROM TABLES 1A+1 B) BUILDING TOTAL 1.207 0 EnergyPro 3.1 By EnergySoft User Number: 5289 Job Number: 062003 Paae:5 of 16 LIGHTING COMPLIANCE SUMMARY LTG -2 PROJECT NAME DATE Curves Diet Center 2/12/2003 LUMINAIRE It1RM� 4 ft Fluorescent T8 Elec COMPLETE BUILDING METHOD NUMBER OF LUMiNAIR 10 WATTS PER LUMINAIRE ktcfudirt i. BaHastk CEC DEFAULT Y 1A!• 62.0 ® ❑ ,F] El ❑❑ ❑❑ ❑❑ ❑❑ ❑❑ uu ❑❑ Total Watts 620 Subtotal from this Page 620 Building Total 620 Portable Lighting (From LTG -1) 01 Less Control Credit Watts (From LTG -3) 310 Adjusted Actual Watts 310 BUILDING CATEGORY (From Table 1-M) WATTS COMPLETE ALLOWED PER SF BLDG. AREA WATTS AREA CATEGORY METHOD AREA CATEGORY (From Table 1-N) Retail/Wholesale Sales WATTS AREA ALLOWED PER SF (SF) WATTS 2.00 1,207 2,414 P TQTAL 1,201, 2,414 BUILDING TOTAL 1 207 2 414 AREA WATTS TOTAL ALLOWED WATTS` D EnergyPro 3.1 By EnergySoft User Number 5289 Job Number: 062003 Page:6 of 16 1 LIGHTING CONTROL CREDIT WORKSHEET LTG - PROJECT NAME Curves Diet Center DATE 2/12/2003 WORKSHEET a ROOM # ZONE ID © LYGHMG CONTROL DESCRIPTION © PLA118 REF. o FROOM AREA (SF) a DAYLIGHTING o © WATTS OF CONTROL LIGHTING 0 LIGHTING ADJUST. FACTOR 0 I CONTROL I CREDW S WAIG X H ROOM RATIO" GLAZING VLT Diet Center Daylighting Controls - 50% 1 207 620 0.50 310 Enter on LTG -1 PAGE BUILDING and 2: Actual Lighting TOTAL TOTAL Power 310 • For windows, use For skylights, use the Window Wall Ratio for the Skylight -to -Roof ratio the room. for the room. 310 calculation. EnergyPro 3.1 By Energysoft User Number 5289 Job Number: 062003 Page:7 of 16 LIGHTING MANDATORY MEASURES LTG -MM PROJECT NAME Curves Diet Center DATE 2/12/2003 DESCRIPTION Designer Enforcement § 131(d)1 For every floor, all Interior lighting systems shall be equipped with a separate automatic control to shut off the lighting. This automatic control shall meet the requirements of Section 119 and may be an occupancy sensor, automatic time switch, or other device capable of automatically shutting off the lighting. ❑ § 131(d)2 Override for Building Lighting Shut-off: The automatic building shut-off system is vmvil4 with a manua6 aowaa :1 Yon ift mfth in *WM of tha Wit Ttm aria $f override Is not to exceed 5,000 square feet. § 119(h) Automatic Control Devices Certified: All automatic control devices specified are certified, all alternate equipment shall be certified and Installed as directed by the manufacturer. n§ 111 Fluorescent Ballast and Luminaires Certified: All fluorescent fixtures snecifIed for the project are certified and listed in the Directory. All installed fixtures shall be certified. X❑ § 132 Tandem Wiring for One and Three Lamp Fluorescent Fixtures: All one and three lamp fluorescent fixtures are tandem wired with two lamp ballasts where required by Standards Section 132; or all one and three lamp fluorescent fixtures are specified with electronic ht�qh-frequency ballasts and are exempt from tandem wiring requirements. 0 § 131(a) Individual Room/Area Controls: Each room and area in this building is equipped with a separate switch or occupancy sensor device for each area with floor -to -ceiling walls. § 131(b) Uniform Reduction for Individual Rooms: All rooms and areas greater than 100 feat and mew tt!z-- " watts pw sclimse foot of ti g.load ahatl.be controlled with bi-level switching for uniform reduction of lighting within the room. r § 131(c) Daylight Area Control: All rooms with windows and skylights that are greater than 250 square feet and that allow for the effective use of daylight In the area shall have 50% of the lamps in each daylit area controlled by a separate switch; or the effective r use of dayftht cannot be accomplished because the wkWoays are continuously. shaded by a building on the adjacent lot. Diagram of shading during different times of the year is included on plans. § 131(f) Control of Exterior Lights: Exterior mounted fixtures served from the electrical panel inside the building are controlled with a directional photo.cell control on the roof and a corresponding relay in the electrical panel, or uses an astronomical time clock. ❑ § 131(e) Display Lighting. Display lighting shall be separately switched on circuits that are 20 amps or less. ❑ §.130(c) Efficacy of Exterior Lights: Exterior mounted fixtures with lamps over 100 Watts served from the trectrtcaP parrei inside thebuhtift'haae a source effrcacyorat least 60 lumens per Watt, or are controlled by a motion sensor. EnergyPro 3.1 By EnergySoft User Number: 5289 Job Number: 062003 Page78 of 16 CERTIFICATE OF COMPLIANCE Part 1 of 2 MECH-1 PROJECT NAME DATE Curves Diet Center 2/12/2003 PROJECT ADDRESS BUILDING TYPE ® NONRESIDENTIAL ❑ HIGH RISE RESIDENTIAL ❑ HOTELIMOTEL GUEST ROOM 78-595 Hwy 111 Suite 150 La Quinta METHOD OF MECHANICAL ® PRESCRIPTIVE ❑ PERFORMANCE PRINCIPAL DESIGNER - MECHANICAL TELEPHONE Building Permit # }FO2YrIihlErirTArROW AUT+tOR Sipovac Construction (760) 779-0790 Checked-by/Date Enforcement Agency Use GENERAL INFORMATION DATE OF PLANS BUILDING CONDITIONED FLOOR AREA 01 /25/2003 �CLIMATEZONE 1,207Sq.Ft. 15 BUILDING TYPE ® NONRESIDENTIAL ❑ HIGH RISE RESIDENTIAL ❑ HOTELIMOTEL GUEST ROOM PHASE OF CONSTRUCTION ❑ NEW CONSTRUCTION ❑ ADDITION X❑ ALTERATION ❑ EXISTING + ADDITION METHOD OF MECHANICAL ® PRESCRIPTIVE ❑ PERFORMANCE COMPLIANCE PROOF OF ENVELOPE COMPLIANCE ❑ PREVIOUS ENVELOPE PERMIT ❑ ENVELOPE COMPLIANCE ATTACHED STATEMENT OF COMPLIANCE This Certificate of Compliance lists the building features and performance specifications needed to comply with Title 24, Parts 1 and 6 of the California Code of Regulations. This certificate applies only to building mechanical requirements. The documentation preparer hereby certifies that the documentation is accurate and complete. DOCUMENTATION AUTHOR SIGNAT DATE -Bob Si ovac Jr. i 05 1 The Principal Mechanical Designer hereby certifies that the proposed building design represe pa in this sef4constructi6n documents is consistent with the other compliance forms and worksheets, with the specifications, and with any other calculations submitted with this permit application. The proposed building has been designed to meet the mechanical requirements contained in Sections 110 through115, 120 through 124, 140 through 142, 144 and 145. Please check one: ❑ I hereby affirm that I am eligible under the provisions of Division 3 of the Business and Professions Code to sign this document as the person responsible for its preparation; and that I am licensed in the State of California as a civil engineer, or mechanical engineer or I am a licensed architect. ❑ 1 affirm that I am eligible under the exemption to Division 3 of the Business and Professions Code by Section 5537.2 or 6737.3 to sign this document as the person responsible for its preparation; and that I am a fterrsed twrtractcrr perkrnrrirrg this work. ❑ I affirm that I am eligible under the exemption to Division 3 of the Business and Professions Code to sign this document because it pertains to a structure or type of work described pursuant to Business and Professions Code sections 5537, 5538, and 6737.1. PRINCIPAL MECHANICAL DESIGNER - NAME SIGNATURE DATE LIC. # I MECHANICAL MANDATORY MEASURES Indicate location on plans of Note Block for Mandatory Measures INSTRUCTIONS TO APPLICANT For detailed instructions on the use of this and a!I Energy Efficiamy Standards compliance forms, please refer to the Nonresidential Manual published by the California Energy Commission. MECH-1: Required on plans for all submittals. Parts 2 may be incorporated in schedules on plans. MECH-2: Required for all submittals, but may be incorporated in schedules on plans. MECH-3: Required for all submittals unless required outdoor ventilation rates and airflows are shown on plans per Section 4.3.4. MECH=4: Required for Prescriove submittals. MECH-5: Opti - nal. Performance use only for mechanical distribution summa!)f. EnergyPro 3.1 By EnergySoft User Number: 5289 Job Number: 062003 Page:9 of 16 CERTIFICATE OF COMPLIANCE Part 2 of 2 MECH-1 (PROJECT NAME DATE Curves Diet Center 2/12/2003 SYSTEM FEATURES SYSTEM NAME TIME CONTROL SETBACK CONTROL ISOLATION ZONES HEAT PUMP THERMOSTAT? ELECTRIC HEAT? FAN CONTROL VAV MINIMUM POSITION CONTROL? SIMULTANEOUS HEAT/COOL? HEATING SUPPLY RESET COOLING SUPPLY RESET HEAT REJECTION CONTROL VENTILATION OUTDOOR DAMPER CONTROL ECO9KW2r--R TVA DESIGN O.A. CFM MECH-3 COLUMN I HEATING EQUIPMENT TYPE HEATING EQUIPMENT EFFICIENCY COOLING EQUIPMENT TYPE COOLING EQUIPMENT EFFICIENCY MAKE AND MODEL NUMBER PIPE INSULATION REQUIRED? PIPE/DUCT INSULATION PROTECTED? HEATING DUCT LOCATION I R -VALUE COOLING DUCT LOCATIONR-VALUE VERIFIED SEALED DUCTS IN CEILING/ROOF SPACE MECHANICAL SYSTEMS HVAC # 1 11 Programmable Switch Heating & Cooling Required n/a n/a n/a Constant Volume No No Constant Temp Constant Tem n/a Air Balance Auto f�irz. t`oo<.+ar 302 cfm Gas Furnace 80% AFUE Packaged DX 5.7 SEER 1-8.6 EER BDP CO. 561AJ060-"" Yes Yes Ducts in Attic I 4.2 Ducts in Attic 4.2 No NOTE TO EnergyPro 3.1 By EnergySoft User Number: 5289 Job Number: 062003 1 Page: 10 of 16 CODE TABLES: Enter code from table below Into columns above. a :REAT, Pt_eW T; tEtaes, OST( ATT? ELECTRIC HEAT? TME CGNTR L SETBACK CTRL. . ISOLATION ZONES I FAA! CMTROL S: Prog. Switch O: Occupancy Sensor M: Manual Timer H: Heating C: Cooling B: Both Enter Number of Isolation Zones. I: Inlet Vanes P: Variable Pitch V: VFD O: Other C: Curve VAV MINIMUM POSITION CONTROL? SIMULTANEOUS HEAT / COOL? Y: Yes N: No HEAT AND COOL SUPPLY RESET? VENTILATION OUTDOOR DAMPER ECONOMIZER O.A. CFM HIGH EFFICIENCY? B: Air Balance out. de -Pea M: Out. Air Measure D: Demand Control N: Natural A: Auto a1 -4- A: Air `` N: Not Required EC: Economizer Control See Section Enter Outdoor Air Vim`' Note: This shall be no less than Col. H on MECH-3. PIPE INSULATION REQUIRED? PIPE/DUCT INSULATION PROTECTED? SEALED DUCTS IN CEILING/ROOF SPACE EnergyPro 3.1 By EnergySoft User Number: 5289 Job Number: 062003 1 Page: 10 of 16 MECHANICAL EQUIPMENT SUMMARY Part 1 of 2 MECH-2 ROJE£'r MME Curves Diet Center DATE2/12/2003 CHILLER AND TOWER SUMMARY Efficiency Tons PUMPS Equipment Name Equipment Type Qty. Tot. Qty GPM BHP Motor Eff. Drive Eff. Pump Control none TANK INSUL. Energy Factor or Recovery Efficiency Standby Loss or Pilot System Name System Type Distribution Type Q Rated Input (Gals.) Vol. Ext. R-Val. L CENTRAL SYSTEM RATINGS HEATING COOLING System Name System Type Qty. Output Aux. kW Eff. Output Sensible Efficiencv Economizer Type CO. 561 AJ060="" Packaged UX i 'Q4,iJiJU 0.101F6W6 AFUEj 57'.-- n", 'JTSEERi"S.6'EE—K INO Economizer CENTRAL SYSTEM FAN SUMMARY SUPPLY FAN RETURN FAN Motor Drive Motor Drive System Name Fan Type Motor Location CFM BHP Eff. Eff. CFM BHP Eff. Eff. BDP CO. 561AJ060=' Constant Volume Draw -Through 1,905 0.75 77.0%1100.0% I EnergyPro 3.1 By EnergySoft User Number: 5289 Job Number: 062003 Page: 11 none of 16 MECHANICAL EQUIPMENT SUMMARY Part 2 of 2 MECH-2 'FRo;rECTwx>urE Curves Diet Center DATE 2/12/2003 ZONE TERMINAL SUMMARY VAV TERMINAL BOX TERMINAL F BASEBOARD Zone Name System Type City. Min. CFM Ratio Reheat Coil CFM BHP Moto Eff. Drive Eff. :Type=Output Type DeltaT i EXHAUST FAN SUMMARY Room Name Q . CFM BHP Moto Eff. f9rive Eff. i i Motor CFM BHP Eff. l' Drive Eff. Room Name EnergyPro 3.1 By Energysoft User Number: 5289 Job Number: 062003 Page- 12 of 16 MECHANICAL VENTILATION MECH-3 PROJECT NAME DATE Curves Diet Center 2/12/2003 MECHANICAL VENTILATION A] ©© o 0 o FG o o. a o Aik%A aASiS -OCc.ichvm& BASis RE01D. r?'caiGPi COND. MIN. NO. CFM MIN. O.A. OUTDOO VAV ZONE/SYSTEM AREA CFM CFM OF PER CFM (MAX OF AIR MIN. (SF) PER SF (B x C) PEOPLE PERSON (ExF) D OR G) CFM RATIO Tanant Space 1,207 0.25 302 302 302 HVAC # 1 Total 302 302 i I I I II EnergyPro 3.1 By EnergySok User Number: 5289 Job Number: 062003 Page: 13 of 16 1 MECHANICAL SIZING AND FAN POWER MECH-4 PROJECT NAME DATE Curves Diet Center 2/12/2003 SYSTEM NAME HVAC # 1 FLOOR AREA 1,207 INOTE: Provide one copy of this form for each mechanical system when using the Prescriptive Approach. SIZING AND EQUIPMENT SELECTION 1. DESIGN CONDITIONS: - OUTDOOR DRY BULB TEMPERATURE .0"T, i a.a.z - INDOOR, DRY BULB TEMPERATURE 2. SIZING: - DESIGN OUTDOOR AIR - i�i'i?M��LcOS RETURN VENTED LIGHTING - RETURN AIR DUCTS - RETURN FAN - SUPPLY FAN - SUPPLY DUCTS (APPENDIX C) SEE ASHRAE CHAPTER 8, 1993 OR APPENDIX B COOLING HEATING 112 OF 26 OF 741 OF 70 OF 30.2 CFM (MECH 3; COLUMN 1) .12 0.75 1d,i'.'3 0 810 0 810 TOTALS SAFETY / WARM-UP FACTOR 1.21 ivr ,�i� ffAUJUSTED_LOAD_(f0fX t_I*15 Ate► i xs =i v i►mr: / nv "r� 36 163 3. SELECTION: INSTALLED EQUIPMENT CAPACITY (ADJUSTED FOR DESIGN CONDITIONS) 35,727 Btu / Hr IF INSTALLED CAPACITY EXCEEDS MAXIMUM FAN DESCRIPTION DESIGN. BRAKE HP .��a�Y'�ati rj.T�u • F61 a EFFICIENCY MOTOR =DRIVE I 77.' '01 1"UU:0- NOTE: Include only fan systems exceeding 25 HP (see Section 144). Total Fan System Power Demand may not exceed 0.8 Watts/cfm for constant volume systems or 1.25 Watts/cfm for VAV systems. � i EnergyPro 3.1 By EnergySoft User Number 5289 a o NUMBER PEAK WATTS FxEx746/(C,X OF FANS 14,130 n/ 0 0 0 14,130 1.43 20 205 124,070:0] Btu / Hr CFM (Supply Fans) TOTALS 1 727 1 1 905 TOTAL FAN SYSTEM POWER DEMAND. F 0.381 TTS /'CM Col. F / Col. G Job Number: 062003 Page: 14 of 16 MECHANICAL MANDATORY MEASURES Part 1 of 2 MECH-MM PROJECT NAME DATE Curves Diet Center 2/12/2003 DESCRIPTION Designer Enforcement Equipment and Systems Efficiencies r§111 Any appliance for which there is a California standard established In the Appliance Efficiency Regulations will comply with the applicable standard. a§ 115(a) Fan type central furnaces shall not have a pilot light.' X❑ § 123 Piping, except that conveying fluids at temperatures between 60 and 105 degrees i. Fahrenheit: orwithin•HUAC"eauinment shall 6e.Insulated.inaccortlancewlth ......................... Standards Section 123...... .. ... .... . . § 124 Air handling duct systems shall be Installed and insulated in compliance with Sections 601, 603 and 604 of the Uniform Mechanical Code. Controls § 122(e) Each space conditioning system shall be installed with one of the following: U § 122(e)1A Each space conditioning system serving building types such as offices and manufacturing facilities (and all others not explicitly exempt from the requirements of Section 112 (d)) shall be installed with an automatic time switch with an accessible manual override that allows operation of the system during off -hours for up to 4 hours. The time switch shall be capable of programming different schedules for weekdays and weekends; incorporate an automatic holiday "shut - scheduled operation; and has program backup capabilities that prevent the loss of the device's program and time setting for at least 10 hours if power is interrupted; or § 122(e)1 B An occupancy sensor to control the operating period of the system; or n. � .��,_,�� e�,�,.. ;,��.. t::�t �::: K„� �;; ;;„���,. ,. : ;�.�� :: � �t.• :::,�o .�;,� � a :f too system. 1^1§ 122(e)2 Each space conditioning system shall be installed with controls that temporarily restart and temporarily operate the system as required to maintain a setback heating and/or a setup cooling thermostat setpoint. § 122(8) Each space conditioning system serving multiple zones with a combined conditioned floor area more than 25,000 square feet shall be provided with isolation zones. Each zone: shall not exceed 25,000 square feet; shall be provided with isolation devices, such as valves or dampers, that allow the supply of heating or cooling to be setback or shut off independently of other isolation areas; and shall • be controlled by a time control device as described above. F§ 122(a&b) Each space conditioning system shall be controlled by an individual thermostat • that responds to temperature within the zone. Where used to control heating, the control shall be adjustable down to 55 degrees F or lower. For cooling, the control shall be adjustable up to 65 degrees F or higher. Where used for both heating and cooling, the control shall be capable of providing a deadband of at least 5 degrees F within which the supply of heating and cooling is shut off or reduced to a minimum. F§ 122(c) Thermostats shall have numeric setpoints In degrees Fahrenheit (F) and adjustable setpoint stops accessible only to authorized personnel. § 112(b) Heat pumps shall be installed with controls to prevent electric resistance supplementary heater operation when the heating load can be met by the heat pump aiurre. EnergyPro 3.1 By EnergySoft User Number: 5289 Job Number: 062003 Page: 15 of 16 MECHANICAL MANDATORY MEASURES = Part 2 of 2 MECH-MM PROJECT NAME DATE Curves Diet Center 2/12/2003 Description IDesigner lEnforcement Ventilation § 121(e) Controls shall be provided to allow outside air dampers or devices to be operated at the ventilation rates as specified on these plans. ❑ § 122(f) Gravity or automatic dampers interlocked and closed on fan shutdown shall be provided on the outside air intakes and discharges of all space conditioning and exhaust systems. § 122(f) All gravity ventilating systems shall be provided with automatic or readily accessible manually operated dampers in all openings to the outside, except for combustion air openings. . X] § 121(f)1 Air Balancing: The system shall be balanced in accordance with the National Environmental Balancing Bureau (NEBB) Procedural Standards (1983), or . A------i.'.t:.d. A!- San !--nv.'�_ .r..nun.-i! 1 A B11 M. -*;on-- 1 vb.2nd.--de+ 'I 220q: F -I§ 121(f)2 Outside Air Certification: The system shall provide the minimum outside air as shown on the mechanical drawings, and shall be measured and certified by the installing licensed C-20 mechanical contractor and certified by (1) the design mechanical engineer, (2) the installing licenced C-20 mechanical contractor, or (3) the person with overall responsibility for the design of the ventilation system; or U § 141({)3 Outside Air Measurement: The system shall be equipped with a calibrated local or remote device capable of measuring the quantity of outside air on a continuous basis and displaying that quantity on a readily accessible display divice; or F -I§ 121(f)4 Another method approved by the Commission. a Service Water Heatinca Svstems ❑ § 113(b)2 if a circulating hot water system is installed, it shall have a control capable of automatically turning off the circulating pump(s) when hot water is not required. § 113(b)3B Lavatories in restrooms of public facilities shall be equipped with controls to limit the outlet temperature to 110 degrees F. � FX I S 11'41hVI ' Lavatories in real roams of public facilities shall be eauiooed with one of the following: Outlet devices that limit the flow of hot water to a maximum of 0.5 gallons per minute. Foot actuated control valves, and outlet devices that limit the flow of hot water to a rraxiniti r JSb.°r`'rr�a'ri69'rS �S--"WrV z&. Proximity sensor actuated control valves, and outlet devices that limit the flow of hot water to a maximum of 0.75 gallons per minute. Self-closing valves, and outlet devices that limit the flow of hot water to a maximum • , of 2.5 Gallons nor minute. and 0.25 oallons/cvcle (circulating system). Self-closing valves, and outlet devices that limit the flow of hot water to a maximum of 2.5 gallons per minute, and 0.50 gallons/cycle (non -circulating system). Self-closing valves, and outlet devices that limit the flow of hot water to a maximum of 2.5 gallons per minute, and 0.75 gallons/cycle (foot switches and proximity sensor e�r�aisy. EnergyPro 3.1 By EnergySoft User Number: 5289 Job Number: 062003 Page: 16 of 16