06-2928 (CSCS)t
P.O. BOX 1504
78-495 CALLE TAMPICO
LA QUINTA, CALIFORNIA 92253
Application Number: % 06-00002928
Property Address: 78730 HIGHWAY 111
APN: 643-220-024- -
Application description: NEW COMML - STORES
Property Zoning: MEDIUM DENSITY RES
Application valuation: 442410
Applicant:
T4ht 444"
BUILDING & SAFETY DEPARTMENT
BUILDING PERMIT
& CUSTOMER SERVICE
Architect or Engineer: .
LICENSED CONTRACTOR'S DECLARATION
I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with
Section 7000) of Division3 of the Business and Professionals Code, and my License is in full force and effect.
License Class: B C8 License No.: 824183
Date: 0 Contractor:
OWNER -BUILDER DECLARATION
I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the
following reason (Sec. 7031 .5, Business and Professions Code: Any city or county that requires a permit to
construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the
permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State
License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or
that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by
any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).:
(_ 1 I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and
the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The
Contractors' State License Law does not apply to an owner of property who builds or improves thereon,
and who does the work himself or herself through his or her own employees, provided that the
improvements are not intended or offered for sale. If, however, the building or improvement is sold within
one year of completion, the owner -builder will have the burden of proving that he or she did not build or
improve for the purpose of sale.).
(_ 1 I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec.
7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of
property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed
pursuant to the Contractors' -State License Law.).
(_ I I am exempt under Sec. , B.&P.C. for this reason
Date:
Owner:
CONSTRUCTION LENDING AGENCY
I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the
work for which this permit is issued (Sec. 3097, Civ. C.).
Lender's Name: _
Lender's Address:
LQPERDIIT
Owner:
ONE ELEVEN LA QUINTA
C/O SABBY JONATHAN ,
42620 CAROLINE CT STE 102
PALM DESERT, CA 92211
Contractor:
CONSOLIDATED CONTRACTING, I
46753 ADAMS STREET
LA QUINTA, CA 92253
(760) 771'-3345
Lic. No.: 824183
VOICE (760) 777-7012
FAX (760) 777-7011
:INSPECTIONS (760) 777-7153
Date: 4/12/07
.ems• 1 •,
WORKER'S COMPENSATION DECLARATION
I hereby affirm under penalty of perjury one of the following declarations:
_ I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided
for by Section 3700 of the Labor Code, for the performance of the work for which this permit Is
issued.
I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor
Code, for the performance of the work for which this permit is issued. My workers' compensation
insurance carrier and policy number are:
Carrier STATE FUND Policy Number 1770749-2007
I certify that, in the performance of the work for which this permit is issued, I shall not employ any
person in any manner so as to become subject to the workers' compensation laws of California,
and agree that, if I should become subject to the workers' compensation provisions of Section
3700 of the Labor Code sh)forth comply with those provisions.
Date: Applicant:
WARNING: FAILURE TO SECU WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL
SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND
DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN
SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES.
APPLICANT ACKNOWLEDGEMENT '
IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the
conditions and restrictions set forth on this application.
1 . Each person upon whose behalf this application is made, each person at whose request and for
whose benefit work is performed under or pursuant to any permit issued as a result of this application,
the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City
of La Quinta, its officers, agents and employees for any act or omission related to the work being
performed under or following issuance of this permit.
2. Any permit issued as a result of this application becomes null and void if work is not commenced
within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject
permit to cancellation.
I certify that I have read this application and state that the above information is correct. I agree to comply with all
city and county ordinances and state laws relating to building construction, and hereby authorize representatives
of this ccu to enter upon the above -mentioned property f pection p oses.
Date: V (Signature (Applicant or Agent):
Application Number ".
. . . . 06-00002928
Permit . .
BUILDING PERMIT
Additional desc
Permit -Fee . .
1840.00
Plan Check Fee
1196.00
Issue Date . . . .
Valuation . . . .
442410
Expiration Date
5/07/07
Qty Unit Charge
Per
Extension
BASE
FEE
639.50
343.00 3.5000
-------------------------------------------------------------------
THOU BLDG
100,001-500,000 ,,..,
1200.50
Permit
ELEC-NEW COMMERCIAL
Additional desc .
Permit Fee . . .
230.54
Plan Check Fee
57.64
Issue Date . . . .
Valuation
0
Expiration Date
5/07/07
Qty . Unit Charge
Per
Extension
BASE
FEE
15.00
10777.00 .0200
-----------------------------------------------------=
ELEC
GARAGE OR NON-RESIDENTIAL
------------=---------
215.54
Y Permit . . .
GRADING PERMIT
Additional desc .
'Permit Fee . . . .
15.00
Plan Check Fee
.00
Issue Date . . . .
Valuation
0
Expiration Date
5/07/07
Qty Unit Charge
Per
Extension
----------------------------------------------------------------------------
BASE
FEE
15.00
Permit . . .
MECHANICAL
Additional desc .
Permit Fee . . . .
124.50
Plan Check Fee
31.13
Issue Date . . . .
Valuation . . . .
0
Expiration Date
5/07/07
Qty Unit Charge
Per
Extension
BASE
FEE
15.00
5.00 9.0000
EA MECH
FURNACE <=100K
45.00
5.00 9.0000
EA MECH
B/C <=3HP/100K BTU
45.00
3.00 6.5000
----------------------------------------------------------------------------
EA MECH
VENT FAN
•19.50
Permit . . .
PLUMBING
Additional desc .
LQPERn4IT
Application Number .
. . . . 06-00002928
Permit . . . .
PLUMBING
Permit Fee
91.50 Plan Check Fee
22.88
Issue Date
Valuation . . .
. 0
Expiration.Date
5/07/07
Qty Unit Charge,.
Per
Extension
BASE FEE
15.00
6.00 6.0000
EA PLB FIXTURE
36.00
1.00 15.0000
EA PLB BUILDING SEWER
15.00
3.00 7.5000
EA- PLB WATER HEATER/VENT
22.50
1.00 3.0000
'EA" PLB WATER INST/ALT/REP
13.00
----------------------------------------------------------------------------
Special Notes'and Comments
18000 SF RETAIL SHELL/2867
SF STORAGE
Other Fees . . . .".
. . . . ACCESSIBILITY PLAN REVIEW
63.95
ART IN PUBLIC PLACES-COM
2192.05
DIF CIVIC CENTER - COMM
1498.00
ENERGY REVIEW FEE
63.95
DIF FIRE PROTECTION-COMM
215.54
HOURLY PLAN CHECK
175.00
STRONG MOTION (SMI) - COM
92.90
DIF STREET MAINT FAC-COMM
1401.00
DIF TRANSPORTATION - COMM
40187.43
Fee summary- Charged
Paid Credited
Due
Permit Fee Total
2301.54 .00 .00
2301.54
Plan Check Total
1307.65 800.00 .00
507.65
Other Fee Total
45889.82 .00 .00
45889.82
Grand Total
49499.01 800.00 .00
48699.01
LQPERMIT
Cr city of La Q uinta
.
Bluum
asafety
Permit # nn P.O Box 1504, 78-495 Cab Tampico
�to Qtdnt , CA 92253 - (760) 777-7012
Banding Permit Application and Tracking Sheet
P''0jectAddre=%8--7--3oOwY tf I Ownet'sName: dl(6
A. P. Nmber: (P4 32-Zd cS Ammss- j l c>64 rA vtAR *k— I-AAr,-
Legal
on:`PA2a% �� M• #� ► i cdy, ST Tip: F�A,406 M I RA
contractor ej�AjWU (20WR,4fTj4 61 sad.. Tom= d•3u1 - S4 S—
Addnm: 7g-753 AD� K-- cr, . Project D
city, sT, zip: LA oi,,fm CAA. '3 Zz--5,3 �S - 57o ACq e
Telephone:IG6I ` 33415 sm. SEE s. -?QS - V 59 t -
state Liu # : 18-3 City Lic. #: -
Arch., Eng., Designer CAZL C,6X A I
Addaess:,SI657 -bR�
city, ST, Zip:--r:4bj0 66, q -,7
Telephone-" 7JLDD-34j • Ot7 .: `
,� � {
State Lam- #: `739 " - ` .f „ t
_
Name of cunt= Person LL- 6AsG-,
Construction Type:
V R cr-
Project type (circle one). New Add', Altm Demo
Repair
Sq. Ft: -I
#Stories
# Units: 2-
Telephone # of Contact Pelson - -7 -11 - 334-S
Estimated Value of Project:
APMCANT- DO NOT VVRrM 8MOWi THIS UM
d
Submittal
RM-d
Reed
TRACKING
PERNW FM
Phu Sets
Pfau Cke& submdued
Amout
Straetaral (afea
Reviewed, read? corregiens
Phu OW& Deposit
ltvssGales.
CancelcomisdPerma
P6aC Safa>toe-
�fitfc 1A Calm
Phi p d W ap
019 6
Cow '
FUW � &a
Plans rmbmiftd
�° y U b
leiecha,iraf
Grading P-
r! Review, ready for
Electrical
Subcoatactor Iyst
caned Contact Person
G �7
PI —big
Grant Deed
Plans picked up
S M.I
$O.A. Approval
I Plans resabmimedGrading
IN MUM-
''' Review, ready far
Developer Impact Fee
Phan Appro►al
caned Contact Pe>W--
Pub. Wks. Appr
Date of permit Gssse
S&od Fees
Total
G 0(oj SeT P�Ms / C6jC CS :lu Uc S i DV,6 : 8 3 C6
8� C; se-, s To COD 6� �J�� 8/�3IC&
to i� O� ��n�(WIPI��6►� ��
gVO&c, )v�m�&E/5-/0(o 57P-ArROv�V
AUG' 17 2006
CITY OF LA QUINTA
FINANCE DEPT.
Q n /�
Certificate of Occupancy
T _44Q"
Building & Safety Department
This Certificate is issued pursuant to the requirements of Section 109 of the California Building
Code, certifying that, at the time of issuance, this structure was in compliance with the
provisions of the Building Code and the various ordinances of the City regulating building
construction and/or use.
BUILDING ADDRESS: 78-730 HIGHWAY 111
Use classification: COMMERICAL (STORAGE UNITS)
Occupancy Group: B Type of Construction: II V-N
Special Conditions: STORAGE UNITS ONLY.
Owner of Building: ONE ELEVEN LA QUINTA
Building Official
Building Permit No.: 06-2928
Land Use Zone: RM
Address: 42-620 CAROLINE CT #102
City, ST, ZIP: PALM DESERT, CA 92211
By: STEVE TRAXEL
Date: FEB 28, 2008
'
CERTIFICATE OF COMPLIANCE
Desert Sands Unified School District�
p���Fi���o
f1L
-
47950 Dune Palms Road
BERMUDADUNES O
Date
4/18/07
La Quinta, CA 92253
rn RANCHO MIRAGE �f
INDIAN WELLS +.
No.
29354
(760) 771-8515
d PALM DESERT
`� LAINDIO A
�QINDIo
0
Owner
One Eleven La Quinta
APN #
643-220-024
Address
78730 Hwy 111
Jurisdiction
La Quinta
City
La Quinta Zip 92253
Permit #
Tract #
Study Area
Type
Commercial
No. of Units
Lot # No. Street
S.F. Lot # No.
Street S.F.
Unit 1
78730 Hwy 111
10777 Unit 6
Unit 2
Unit 7
Unit 3
Unit 8
Unit 4
Unit 9
Unit 5
Unit 10
Comments Ck amount $4,527.60 overpaid by $1.26 refunded in cash.
At the present time, the Desert Sands Unified School District does not collect fees on garages/carports, covered patiostwalkways, residential additions under 5
00 square feet, detached accessory structures (spaces that do not contain facilities for living, sleeping, cooking, eating or sanitation) or replacement mobile ho
mes. It has been determined that the above -named owner is exempt from paying school fees at this time due to the following reason:
EXEMPTION NOT APPLICABLE
This certifies that school facility fees imposed pursuant to
Education Code Section 17620 and Government Code 65995 Et Seq.
in the amount of $0.42 X 10,777 S.F. or $4,526.34 have been paid for the property listed above and that
building permits and/or Certificates of Occupancy for this square footage in this proposed project may now be issued.
Fees Paid By CC/Wells Fargo -Maria Marchetti Check No. 0068924503
Name on the check Telephone 760-
Commercial
By Dr. Doris Wilson
SuperintendentIV 10.
Fee collected /exempted by Yolanda Garcia Payment Recd 0.00 7�'- X
".Over/UUnder
$4,526.34 c-,
Signature
NOTICE: Pursuant to Government Code Section 66020(d)(1), this will serve to notify you that the 90-day approval period in which you may protest the fees o
r other payment identified above will begin to run from the date on which the building or installation permit for this project is issued, or from the date on which
those amounts are paid to the District(s) or to another public entity authorized to collect them on the District('s) behalf, whichever is earlier.
}
NOTICE: This Document NOT VALID if Duplicated
Embossed Original - Building Department/Applicant Copy - Applicant/Receipt Copy - Accounting
CITY :OF LA:QUINTA.- PUBLIC WORKS/ENGINEERING.DEPARTMENT
GREEN SHEET (PUBLIC WORKS CLEARANCE) FOR BUILDING PERMITS
Form updated & effective 8/25/2005
Please :.DO :NOT submit the Green Sheet -(Public Works Clearance) Packet. to: °the . Public.
Works/Engineering Department. until . ALL requirements listed below are .complete:. Incomplete
applications or ' applications which cannot be processed will be returned to Applicant:: Green "Sheet
approvals will be forwarded to the Building Department directly by Public Works:: .
Date' DevelopernlDW)RT
Tract No.: N,4 3104.1 Tract Name: 12�Tf+►L�5'(a2�f c' Lot No.(s): .
Address(s): -7 Y- 30 6 Ft' w I l
.The following are the. requirements 'for Public Works Clearance to authorize, issuance. of a building 1
permit from the Building/Safety Department.
CUSTOM .HOMES: PROVIDE ITEMS#2 -#3 #4 AND #5 BELOW: "
TRACT I1OMES: PROVIDE ITEMS #1, #2, #3, 94 (AS APPLICABLE) AND #6 BELOW
COMMERCIAL BUILDINGS/OTHER: PROVIDE ITEMS #1 #2 #3'AND #S BELOW..
1. Attach. Pad Elevation .Certificates in compliance with the approved design ' elevation . for
building pad (maximum allowable deviation of +/- 0.1 foot): Pad Elevation. Certificates must
be current (within 6 months .of current date). If a precise grading plan creates: the:*
..pad for
approval, please withhold green sheet submittal until a. Pad Elevation. Certificate: can' be.
provided.
2. Attach geotechnical certification of grading plan compliance:.
3. Attach recorded final "map showing proposed building locations are legal lots.
4. Attach a completed <1 acre per lot or infill project Fugitive'Dust Control project. information
form, PM10 plan &,agreement. or.provide alternative & valid City approved PM10 plan set
reference. number or -hard copy plan. PM10 plans for cornrriercial,and residential developments
(beyond 1 lot) 'are submitted separately with grading plans and are subject to additional
.requirements. RE(`
5: Attach. an' approved precise grading plan. for the building location(s). ACrITAV.
developments will require an approved flood plain development plan. MAY 6. Attach an approved rough grading plan for the building location(s). 3 1 2001.
I.have reviewed and confirmed the requirements listed above as Presented and find the im r �WS
. p vemE.
to be sufficiently complete for construction of a proposed buildings)/sttucture(s). on the subject
lot(s). Pursuant to the ove proj t ay be released. for building permit" issuance.
Recommended' by: Dated:
Declined for approval for reasons) as follow(s), please correct and resubmit7:
T:\PWDEPT\STAFFWmWc\Green Sheet PW Rdeaub50824GREEN SHEET COVERdoe
City of La Quinta `- PM 10Project Information (<1 acre per Lot or Inf ll Proiect)R Page 1 of 3
Form updated & effective 8/25/2005
Project Information . Project Contractor:
Project Phase
CTY�►�Ce�FG'flY�iC:.. tV IL
Project Phase Project Name:
*0L -mn__AG.
ec
Construction
❑ Demolition .
�
Project Tract
Number:../W
:-
���
Lot Number(s):
Anticipated Start Dater
Project Street.
Address:
-7 8,--7 qdOtiUJ,/
_3
Anticipated Completion:
Total acres in active
construction (<1 acre per
Lot):
Project Contact
Information
Please Note: Dust control is required 24 hours a day, 7 days a week,
regardless of construction status. Person listed below is responsible for
dust control during business and non- business hours.
Name:
Title:. ...
R • . Ui% CVnlrR-O c-f (D
Company Name:
C..,) n) :T_tJC-
-Mailing Address:
6 .- S3 AM S ST
City:
LA 601hKA -
State:
GA
Zi : Code:
Primary
Telephone
Number:
(eO= -j l -334-5
Fax:
LO - (-3
24 Hour.
Access/Einergency
Phone:
7&L") 225 r1�1? 2-
Cell Phone:
l 44/ , sr-�<S-0
PM10 Certificate
Number:
b(1.
* Expanded PM10 plans for commercial and residential developments > 1 acre are required -by the
City of La Quinta.
TA WDEMSTAFAGWOCircen Sheri PW ReIe 6050824MM1 PM 10-PACKET GREEN SKEET.doc - - -
V` .
7.
PM 10`(<l. acre per Lot or Infill Proiect) Fugitive Dust ControTPlan . Paee 2 of 3
Plan updated & effective 8/25/2005 . .
This plan shall take into account applicable SCAQIvM Rule.403,regulations.' Training .may be obtained by
contacting SCAQMD (Sharon Zamora. (909) 396-2f83). This plan.shall--consist-of the:foliowing action items:
•. WATERING: Continuous. watering is required to. prevent dust. and must occur a minimum of 4
times daily:
Water shall :be applied to dry soils. to stop:'.
'Visible dust emissions over 20% opacity
• Visible dust emissions that travel over..100 feet:
• Water source'/< in water meter at front (south) side of' ad:
•, EDUCATION: Responsible Dust Control Individual andkey personnel shall attend SCAQMD
PMIO. class and obtain•PM10 certificate number prior to construction activity.,
•. WEATHER MONITORING:' Wind: predictions shall be monitored.
• SIGNAGE: Use Coachella, Valley Fugitive Dust.:Control: PlanHandbook Construction Site Signage .
Guidelines:
• ' .TRAFFIC: .Construction traffic shall, not .be allowed on . the pad, .unless absolutely necessary: If:
vehicles ':operate on. pad,. `pad shall. be kept 'firm ' and moist through hose. watering: or. sprinklers.
Fugitive Dust shall be prevented by fencing off site to prevent unauthorized traffic on pad.: (.15 niph
maximum traffic speed):
PARKING: Parking is.not allowed on'the pad. All vehicles must park ori'.street(at designated areas
only).. .
• TRACK OUT: ,Provide 24 hour street .cleaning and track out system as, approved by. City. Public.
Works Inspector. (No dirt on'public or private'roads)..Track out shall be cleaned up within .one hour
of incident:
• DIRT. PILES: Dirt piles shall be limited to :50 cubic yards and built per California...Building Code
grading requirements-., Piles shall .be kept moist or -covered with tarp material: Larger dirt.piles will :
requirestockpile or grading permit.. <
FENCING: Provide PM10 fencing :at perimeter of public roads and. where applicable. Wood slat,.
fencing. can be.installed at rear of property and return 20 feet on either side if HOA restrictions apply.`
Block walls can replace PM 10 fencing during' the'construction phase. .
• EQUIPMENT:' Extra hoses. and sprinklers. shall be maintained on site..
• EXCAVATION MEASURES: All areas. to be excavated or graded shall be pre -watered. Water shall -
be applied during excavation or grading operations also.
• DUMP TRUCKS: Open top dump trucks to be wet down, moist and tarped prior to leaving site..
INACTIVE SITE: Within 10.days of ceasing -of activities, re -vegetate or:permaneritly stabilize as
required.
. s.
City of La Quinta - Site Specific Construction Phase PM 10 Agreement Page 3 of 3
Agreement updated, & effective 8/25/2005
..The signature of the property .owner or authorized representative):
• Shall act as his/her acknowledgement -of dust control .requirements and their enforceability;
pursuant to AQMD Rules 403 and 403.1
• Shall constitute and agreement to comply with all project conditions as identified .in the.
approved dust control plan;
The property owner (or authorized representative): .
Acknowledges that dust control. is required 24 hours a day,.7 days a'. week throughoutthe
period of project performance, regardless of project size or status;
• Shall ensure that each. and every contractor/subcontractor and all.* other persons associated.
e with thproject shall. be in continuous compliance with all requirements of the approved dust
control plan .
• Shall take all necessary precautions: to minimize .dust, even if additional measures beyond .
those -listed in the dust control plan are necessary
• Shall authorize representative of the'City/County to enter upon the above. mentioned property
for inspection and/or abatement purposes; and
• Shall hold harmless the City/County and its representatives from liability for any actions
related to this dust control plan. or any City/County initiated abatement activities.
1�
Company
JHA ENGINEERING, INCORPORATED
CIVIL ENGINEERING DESIGN • LAND PLANNING • S U R V E Y I N G
EN VIRON MENTAL SERVI CES
May 16; 2007
City of La Quinta _s
78-495 Calle Tampico
. La Quinta, CA..92253-1504 .
Building Department
ATTN- Building Inspection Supervisor
RE: Parcel 4 of Parcel Map No. 30147
Site Address: - Highway 111 (One Eleven La Quinta Shopping Center)
Builder: Consolidated Contracting, Inc. ,
`SDP No.: 2006-859
Gentlemen,
This shall serve as a pad certification letter stating that, the grading for said lot has
been done for the above mentioned property. A field inspection has been performed and shows
that the pad elevation has been graded as noted below;
• Pad Elevation
As -Built Elevation Approved Elevation
' 73.7 73.77
These elevations fall within the standards for grading practice and tolerances.
Sincerely,
pROFESS�O
C,��o�N
John H. Hacker R.C.E. 14614 C 1461'
Ex 1109 EXP.
03.3 49-
0 CIVIL
JHH/wap 9�C�CALIF�F'N\P
41921 BEACON HILL • SUITE A • PALM DESERT, CA. 92211
(760) 7 7 9 - 0 6 5 7 FAX (760) 779-5143
TITLE 24 REPORT
Title 24 Report for:
One -Eleven Center
46-753 Adams Street
La Quinta, Ca 92253 C
-�-Y OF LA Q��NTA
ILDING & SAFETY DEBT
APPROVE
FOR CONST UCTION
DATEIQ Z7 l� BY -
Project. Designer:
Carl Cox, A.I.A..
81-557 Drive, Carreon Blvd., Ste. Al.
Indio, Ca 92201
(760) 347-4007
Report Prepared By:
John Jolly
C+J Technical Solutions and Services, Inc.
1320 Valley Vista Dr. Suite 206
Diamond Bar, CA 91765
(909) 896-3631
Job Number: E
2 2006
Date:
10/4/2006
The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is
authorized by the California Energy Commission for use with both the Residential and Nonresidential 2005 Building Energy Efficiency Standards.
This program developed by EnergySoft, LLC - www.energysoft.com.
EnergyPro 4.2 by EnergySoft Job Number: C06044 User Number: 5950
TABLE OF CONTENTS
Cover Page 1
Table of Contents 2
Nonresidential Performance Title 24 Forms 3
Form ENV-MM Envelope Mandatory Measures 13
Form MECH-MM Mechanical Mandatory Measures 14
EnergyPro 4.2 by EnergySoft Job Number: C06044 User Number: 5950
PERFORMANCE CERTIFICATE OF COMPLIANCE Part 1 of 3 PERF-1
PROJECT NAME
DATE
One -Eleven Center
10/4/2006
PROJECT ADDRESS
........... .
_ .:..
46-753 Adams Street La Quinta
PRINCIPAL DESIGNER - ENVELOPE
TELEPHONE
Building Permit #
Carl Cox, A.I.A.
(760) 347-4007
DOCUMENTATION AUTHOR
C+J Technical Solutions and Services, Inc.
TELEPHONE
(909) 896-3631
Checked by/Date
Enforcement Agency Use
GENERAL INFORMATION
DATE OF PLANS
BUILDING CONDITIONED FLOOR AREA
10,678 Sq.Ft.
CLIMATE ZONE
15
BUILDING TYPE
NONRESIDENTIAL HIGH RISE RESIDENTIAL HOTEL/MOTEL GUEST ROOM
PHASE OF CONSTRUCTION [XIu
NEW CONSTRUCTION ADDITION EXISTING + ADDITION/ALTERATION
STATEMENT OF COMPLIANCE
This Certificate of Compliance lists the building features and performance specifications needed to comply with Title 24, Parts 1 and 6 of the
California Code of Regulations. This certificate applies only to a Building using the performance compliance approach.
The documentation prep arer hereby certifies that the documentation is accurate and complete.
RE DATE
DOCUMENTATION AUTHOR 711&ngUdesign
John Jolly
_ y
The Principal Designer
hereby certifys that the proposed repre nted in this set of construction documents Is
consistent with the other compliance forms and worksheets, with the specifications, and with any other calculations submitted with this
permit application. The proposed building as designed meets the energy efficiency requirements contained in sections 110, 116,
through 118, and 140, 142, 143 or 149 of Title 24, Part 6.
ENV. LTG. MECH.
1. 1 hereby affirm that I am eligible under the provisions of Division 3 of the Business and Professions Code to
sign this document as the person responsible for its preparation; and that I am licensed in the State of
California as a civil engineer, mechanical engineer, or I am a licensed architect.
2. 1 affirm that I am eligible under the provisions of Division 3 of the Business and Professions Code Section
5537.2 or 6737.3 to sign this document as the person responsible for its preparation; and that I am a licensed
contractor performing this work.
❑ 3. 1 affirm that I am eligible under Division 3 of the Business and Professions Code to sign this document
because it pertains to a structure or type of work described as exempt pursuant to Business and Professions
Code Sections 5537, 5538, and 6737.1. (These sections of the Business and Professions Code are printed in
full in the Nonresidential Manual.)
ENVELOPE COMPLIANCE
Indicate location on plans of Note Block for Mandatory Measures
Required For
N -1
PRINCIPAL ENVELOPE DESIGNER - NAME S NA URE
_
LIC. NO. DATE
Carl Cox A.I.A.
C -( `0
LIGHTING COMPLIANCE
Indicate location on plans of Note Block for Mandatory Measures
Lighting Compliance Not In The Scope Of
Required Forms
Th-i'S Submittal
PRINCIPAL LIGHTING DESIGNER - NAME SIGNATURE---]LIC. NO. DATE
MECHANICAL COMPLIANCE
Indicate location on plans of Note Block for Mandatory Measures
Required Forms MECH-1, MECH-2, MECH-3, MECH-5
PRINCIPAL MECHANICAL DESIGNER - NAME SIGPJATURE LIC. NO. DAT
C + J Technical Services and Solutions, ��� I - h31' !'o
EnergyPro 4.2 by EnergySoft User Number 5950 Job Number C06044 Page:3 of 15 1
PERFORMANCE CERTIFICATE OF COMPLIANCE Part 2 of 3 PERF-1
PROJECT NAME DATE
One -Eleven Center 10/4/2006
ANNUAL TDV ENERGY USE SUMMARY kBtu/s ft- r
Standard
ENERGY COMPONENT Design
Space Heating 3.02
Space Cooling 311.22
Indoor Fans 86.61
Heat Rejection 0.00
Pumps & Misc. 0.00
Domestic Hot Water 0.00
Lighting 150.35
Receptacle 68.58
Process 0.00
TOTALS: 619.78
Percent better than Standard:
Proposed Compliance
Design Margin
2.75 0.27
278.96 32.27
103.93 -17.32
0.00 0.00
0.00 0.00
0.00 0.00
150.35 0.00
68.58 0.00
0.00 0.00
604.57 15.21
2.5% ( 2.5% excluding
( Standard
Proposed'
-
SPHmbns
0•20.40 60•80 7DD12014016D•t80200220240260280300
kBtWsgfl-n
keetR*.ti n
""M.``
°'"
Re ep acie
process)
BUILDING COMPLIES
GENERAL INFORMATION
Building Orientation
Number of Stories
Number of Systems
Number of Zones
SE 135 deg
Conditioned Floor Area
Unconditioned Floor Area
Conditioned Footprint Area
Fuel Type
10,678
sgft.
sgft.
sgft.
1
0
5
10,678
5
Natural Gas
Orientation
Front Elevation SE
Left Elevation (SW)
Rear Elevation (NW)
Right Elevation (NE)l
Total
Roof
Gross Area
Glazing
sqft.
sgft.
sgft.
sgft.
sgft.
sgft.sgft.
Area
Glazing
sgft.
sgft.
sgft.
sgft.
sgft.
Ratio
1,109
513
46.3%
0
0
0.0%
854
0
0.0%
1 2.7481
0 1
0.0%
4,711
513
17,135
0.0%
Standard Proposed
Lighting Power Density 1.424 W/sgft. 1.424 W/sgft.
Prescriptive Env. Heat Loss 2,828 Btu/h 3,989 Btu/h
Prescriptive Env. Heat Gain 208,314 Btu/h-F 271,143 Btu/h-F
Remarks:
Run Initiation Time: 07/10/06 17:403 Run Code: 1152578913
EnergyPro 4.2 by EnergySoft User Number: 5950 Job Number: C06044 Page:4 of 15
PERFORMANCE CERTIFICATE OF COMPLIANCE Part 3 of 3 PERF-1
PROJECT NAME
One -Eleven Center
DATE
10/4/2006
ZONE INFORMATION
System Name
Storage
Zone Name
Storage
Occupancy Type
Commercial, Industrial Storage
Floor
Area
(sgft.)
2,537
Inst.
LPD
(Wlsf)1
*0.60
Ctrl.
Credits '
>.(W/sf)2
Allowed LPD
Proc.
Loads
(W/sf)
Area
W/s 3,
Tailored
(Wls 4
Shop
Restrooms
Corridor/Restroom/Support
92
*0.60
Retail
Retail Sales, Wholesale
6,503
*1.70
_
Retail
Retail
Retail Sales, Wholesale
1,500
*1.70
Restroom
Corridor/Restroom/Support
46
*0.60
Notes: 1. See LTG-2-C 2. See LTG-4-C 3. See LTG-5-C 4. See LTG-6-C Items above require special documentation
(items marked with asterisk, see LTG-2 -C by others) (by others)
EXCEPTIONAL CONDITIONS COMPLIANCE CHECKLIST
TI... 1.. ..1 ..s..
- --- ----- a-..-i ....... Y•7 �r.c...o. aucnuvn aa+ ulc uelna specnleo In Inls GneCKIISt. I nese Items require special written justification
and documentation, and special verification to be used with the performance approach. The local enforcement agency determines the adequacy of
the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation
submitted.
HVAC
HVAC
The HVAC
The HVAC
The HVAC
m "York B1 HH048AO6" is designated as 3 Phase, or is Exempte
m "York BP15000OA2/4/5*****" is designated as 3 Phase, or is I
m "Storage" incorporates HERS verified Duct Leakage. Target I,
m "Shop" incorporates HERS verified Duct Leakage. Target leaf
m 'Retail' incorporates HERS verified Duct Leakage. Target lea
from the NAECA 13 SEER requirement.
empted from the NAECA 13 SEER requirement.
kage is calculated and documented on the MECH-5-
ge is calculated and documented on the MECH-5-A.
Ige is calculated and documented on the MECH-5-A.
- - - - - --•- -- ••�•�� ••• ••••� r.. appluaaal appnca[lon nave specmcany peen reviewed. Adequate written justification and
documentation for their use have been provided by the applicant.
EnergyPro 4.2 by EnergySoft User Number: 5950 Job Number C06044 Page:5 of 15 1
CERTIFICATE OF COMPLIANCE ENVA -C
(PROJECT NAME - DATE
One -Eleven Center 10/4/2006
OPAQUE SURFACES
#
Surface
Type
'Area
U-Fac.
Insulation
Cay. Cont.
Act.
Am.
Tilt
Cond:
Status
Joint Appendix
IV Reference
Location /Comments
1
Roof
209
0.036
R-30
R-0.0
0
0
New
02-A9
Storage
2
Wall
105
0.650
None
R-0.0
0
90
New
12-A9
Storage
3
Wall
203
0.650
None
R-0.0
90
90
New
12-A9
Storage
4
Roof
190
0.036
R-30
R-0.0
0
0
New
02-A9
Storage
5
Wall
105
0.650
None
R-0.01
0
90
New
12-A9
Storage
6
Roof
90
0.036
R-30
R-0.01
0
0
New
02-A9
Storage
7
Wall
107
0.650
None
R-0.01
0
90
New
12-A9
Storage
8
Roof
180
0.036
R-30
R-0.01
0
0
New
02-A9
Storage
9
Wall
203
0.650
None
R-0.01
0
90
New
12-A9
Storage
10
lRoof
1 100
0.036
R-30
R-0.0
0
0
New
02-A9
Storage
11
Roof
180
0.036
R-30
R-0.0
0
0
New
02-A9
Storage
12
13
Roof
Wall
120
- 107
0.036
0.650
R-30
None
R-0.0
R-0.0
0
90
0
90
New
New
02-A9
12-A9
Storage
Storage
.14
Roof
100
0.036
R-30
R-0.0
0
0
New
02-A9
Storage
15
Roof
100
0.036
R-30
R-0.0
0
0
New
02-A9
Storage
16
Roof
348
0.036
R-30
R-0.01
0
0
New
02-A9
Storage
17
Wall
55
0.650
None
R-0.0
0
90
New
12-A9
Storage
18
Wall
55
0.650
None
R-0.0
90
90
New
12-A9
Storage
19
Roof
200
0.036
R-30
R-0.0
0
0
New
02-A9
Storage
20
Demising
143
0.650
None
R-0.0
0
90
New
12-A9
Storage (faces Shop
. t&W. cA.auiiy, ^1MIMU,niuveuf
FENESTRATION SURFACES
More than or equal to 10,000 sq.ft. of site -built fenestration area must include a label certificate either issued by NFRC or provide a CEC Default Label Certificate using the default Ll-factors from
Standards Table 116-A and B. Certificate shall be filed in the contractors project office during construction and in the buildin mane efs officeaftt f
#
1
Type
lWindow Front (S)
Area
266
U-Fac'
1.280 116-A
SHGC2
0.67 116-B
Act.
Am.
180
Cond.
Stat.
New
g g er cons ruc on
Glazing Type
Single Metal Tinted
Location/
Comments
Retail
2
lWindow Front (S)
247
1.280
116-A
0.67
116-B
180
New
Single Metal Tinted
Retail
i rra ��-� �o'a��� I able uum Standards, Table Ni-i Default Table from me AGM Manual Appendix, NFRC Labeled value.
(2) SHGC Type: 116-B Default Table from Standards, COG Center of Glass, NFRC Labeled Value
EXTERIOR
SHADING
##
1 -
Exterior Shade Type
None
SHGC
0.76
Window
Hgt. Wd.
9.5 28.0
Overhang
Left Fin
Right Fin
Len. Hgt. LExt.RExt.
12.0 1.3 18.0 18.0
Dist. Len. Hgt.
Dist. Len. Hgt.
2
None
' 0.76
9.5. 26.0
12.0 1.3 18.0 18.0
MINIMUM SKYLIGHT AREA FOR LARGE ENCLOSED SPACES
---•-•-- -- ---•-- ... _
Li••� r•�r��=� .,,...,.a:e Cor.tal..a an encwseu space wflfl floor area greater than zs,uuo sq.ft, a ceiling height greater than 15 feet and a LPD for general lighting of at least 0.5 Wlsq.ft. If this
box Is checked, ENV4-C must be filled out when submitting under the Prescriptive Compliance Approach.
L EnergyPro 4.2 by EnergySoft User Number: 5950 Job Number: C06044 Page:6 of 15 1
CERTIFICATE OF COMPLIANCE ENV-1-C
PROJECT NAME DATE
One -Eleven Center 10/4/2006
OPAQUE SURFACES
.
#
Surface
Type
Area
U-Fac.
Insulation
Cay. Cont.
Act.
Am.
Tilt
Cond.
Status
Joint Appendix
IV Reference
Location / Comments
21
22
Roof
Wall
130
106
0.036
0.650
R-30
None
R-0.0
R-0.0
0
90
0
90
New
New
02-A9
12-A9
Storage
Storage
23
24
Demising
Roof
105
100
0.650
0.036
None
R-30
R-0.0
R-0.0
0
0
90
0
New
1 New
12-A9
02-A9
Storage faces Shop)
Storage
25
IDemising
105
0.650
None
R-0.0
0
90
New
12-A9
Storage (faces Shop
2266
27
Roof
Demising
100
55
0.036
0.650
R-30
None
R-0.0
R-0.0
0
0
0
90
New
New
02-A9
12-A9
Storage
Storage (faces Shop)
28
29
Roof
Demising
50
203
0.036
0.650
R-30
None
R-0.0
R-0.0
0
0
0
90
New
New
02-A9
12-A9
Storage
Storage (faces Shop)
30
31
Roof
Roof
340
46
0.036
0.036
R-30
R-30
R-0.0
R-0.0
0
0
0
0
New
L New
02-A9
02-A9
Storage
Restrooms
32
Wall
566
0.650
None
R-0.0
90
90
1 New
12-A9
Restrooms
33
IRoof
46
0.036
R-30
R-0.0
0
0
New
02-A9
Restrooms
34
lWall
566
0.650
None
R-0.0
90
90
New
12-A9
Restrooms
35
Roof
6,503
0.036
R-30
R-0.0
0
0
New
02-A9
Retail
36
Wall
453
0.650
None
R-0.0
180
90
New
12-A9
Retail
37
Wall
579
0.650
None
R-0.0
90
90
New
12-A9
Retail
38
Roof
1,500
0.036
R-30
R-0.0
0
0
New
02-A9
Retail
39
Wall
258
0.650
None
R-0.0
0
90
New
12-A9
Retail
40
Door
21
0.700
None
R-0.0
0
90
New
28-A2
Retail
. t,.GW. X.5wie, n uiuved/
FENESTRATION SURFACES
I� More than or equal to 10,000 sq.ft. of site -built fenestration area must include a label certificate either issued by NFRC or provide a CEC Default Label Certificate using the default Li -factors from
I j S!3nd3.a� Tab! ,
#
-• •- -- • •� a„� ��,: „w:o
Type
_ �� e�
Area
III I— wiff—IMi s
U-Fac'
protect office during
SHGC2
construction
Act.
Azm.
and in the building
Cond.
Stat.
managers office after construction
Glazing Type
Location/
Comments
1 Uf
t T
- ac or ype. 116-A Default Table from Standards, Table NI-1 Default Table from the ACM Manual Appendix, NFRC Labeled value.
2) SHGC Type: 116.8 Default Table from Standards, COG Center of Glass, NFRC Labeled Value
EXTERIOR
SHADING
#
Exterior Shade Type
SHGC
Window
Hgt. Wd.
Overhang
Left Fin
Right Fin
Len. Hgt. LExt.RExt.
Dist. Len. Hgt.
Dist. Len. Hgt.
MINIMUM SKYLIGHT AREA FOR LARGE ENCLOSED SPACES
Li••_ •- _-----••�•••y CQ•••am•.s a-. ai:c:OsGu apace wfln floor area greater man 25,uou sq.n, a ceiling height greater than 15 feet and a LPD for general lighting of at least 0.5 W/sq.ft. If this
box Is checked, ENV-4-C must be filled out when submitting under the Prescriptive Compliance Approach.
EnergyPro 4.2 by EnergySoft User Number: 5950 Job Number: C06044 Pade:7 of 15 1
a
CERTIFICATE OF COMPLIANCE ENV-1-C
PROJECT NAME DATE
One -Eleven Center 10/4/2006
OPAQUE SURFACES
#
Surface
Type
Area
U-Fac.
Insulation
Cay. Cont.
Act.
Am.
Tilt
Cond.
Status
Joint Appendix
IV Reference
Location / Comments
41
Wall
143
0.650
None
R-0.0
180
90
New
12-A9
Retail
42
Wall
566
0.650
None
R-0.0
90
90
New
12-A9
Retail
43
Roof
6,503
0.036
R-30
R-0.0
0
0
New
02-A9
Restroom
FENESTRATION SURFACES
More than or equal to 10,000 sq.ft. of site -built fenestration area must it Gude a label certificate either issued by NFRC or provide a CEC Default Label Certificate using the default U-factors from
Rfandnrdc Tnhle 11R_A — G nuwit:—_ �,..- . — .— :_ .�_ _- --.-'- -- _ . . .
#
Type .
Area
U-Fac?
SHGCZ
Act.
Am.
Cond.
Stat.
—Illy ,naoay.l � vmce m,el wnswcaon
Glazing Type
Location/
Comments
I
(1) U-farfor
TvnP.' 11R-A r)Pfai ill Tahln from CAi
_ .._......_.__.. ..rr_.._..., .,......,...�,�,..a,�c.
ype: - Default Table from Standards, COG Center of Glass, NFRC Labeled Value
EXTERIOR
SHADING
#Exterior
Shade Type
SHGC
Window
Hgt. Wd.
Overhang
Left Fin
Right Fin
Len. Hgt. LExt.RExt.
Dist. Len. Hgt.
Dist. Len. Hgt.
MINIMUM SKYLIGHT AREA FOR LARGE ENCLOSED SPACES
I� Thn ernnn..a h„ IlAinn
__-_. -.._.. ,,,,.,,, „�,,,,,y „�,y,,, y,�a.�, .na„ ,a ,eel ana a ,_rtr ror general lighting of at least 0.5 W/sq.ft. If this
box is checked, ENV-" must be filled out when submitting under the Prescriptive Compliance Approach.
Run Initiation Time: 07/10/06 17:48:33 Run Code: 1152578913
EnergyPro 4.2 by EnergySoft User Number: 5950 Job Number C06044 Page:8 of 15 I
CERTIFICATE OF COMPLIANCE MECH-1-C
(PROJECT NAME DATE
One -Eleven Center 10/4/2006
Designer:
This form is to be used by the designer and attached to the plans. Listed below are all the acceptance tests for mechanical systems. The designer is required to
check the boxes by all acceptance tests that apply and list all equipment that requires an acceptance test. If all equipment of a certain type requires a test, list the
equipment description and the number of systems to be tested in parentheses. The NJ number designates the Section in the Appendix of the Nonresidential
,ACM Manual that describes the test. Also indicate the person responsible for performing the tests (i.e. the installing contractor, design professional or an agent
selected by the owner). Since this form will be part of the plans, completion of this section will allow the responsible party to budget for the scope of work
appropriately.
Building Departments:
SYSTEM ACCEPTANCE. Before an occupancy permit is granted for a newly constructed building or space, or a new space -conditioning system serving a
building or space is operated for normal use, all control devices serving the building or space shall be certified as meeting the Acceptance Requirements for
Code Compliance.
In addition a Certificate of Acceptance, MECH-I-A Form shall be submitted to the building department that certifies plans, specifications, installation
certificates, and ooeratina and maintenance infnrmntinn moot tho ro—iromcnfe of Q—ti— 1n IWiik% —A T:u ow
STATEMENT OF COMPLIANCE Olt
❑ MECH-2-A: Ventilation System Acceptance Document
-Variable Air.Volume Systems Outdoor Air Acceptance
-Constant Air Volume Systems Outdoor Air Acceptance
Equipment requiring acceptance testing
Test required on all New systems both New Construction and Retrofit. '
❑ MECH-3-A: Packaged HVAC Systems Acceptance Document
Equipment requiring acceptance testing
Test required on all New systems both New Construction and Retrofit.
❑ MECH-4-A: Air -Side Economizer Acceptance Document
Equipment requiring acceptance testing
Test required on all New systems both New Construction and Retrofit. Units with economizers that are installed at the factory and certified with the
commission do not require equipment testing but do require construction inspection.
❑ MECH-5-A: Air Distribution Acceptance Document
Equipment requiring acceptance testing
This test required If the unit serves 5, 000 ft2 of space or less and 25% or more of the ducts are in nonconditioned or semiconditioned space like an
attic. New systems that meet the above requirements. Retrofit systems that meet the above requirements and either extend ducts, replace ducts or
replace the packaged unit.
❑ MECH-6-A: Demand Control Ventilation Acceptance Document
Equipment requiring acceptance testing
All new DC V controls installed on new or existing packaged systems must be tested.
❑ MECH-7-A: Supply Fan Variable Flow Control Acceptance Document
Equipment requiring acceptance testing
All new VA fan volume controls installed on new or existing systems must be tested
❑ MECH-8-A:-Hydronic System Control Acceptance Document
-Variable Flow Controls Applies to chilled and hot water systems.
-Automatic Isolation Controls Applies to new boilers and chillers and the primary pumps are connected to a common header.
-Supply Water Temperature Reset Controls
Applies to new constant flow chilled and hot water systems that have a design capacity greater than or equal to 500,000 Btu/hr.
-Water-loop Heat Pump Controls
Applies to all new watedoop heat pump systems where the combined loop pumps are greater than 5 hp.
-Variable Frequency Controls Applies to all new distribution pumps on new variable flow chilled, hydronic heat pump
or condenser water systems where the pumps motors are greater than 5 hp.
Equipment requiring acceptance testing
Page:9 of 15
EnergyPro 4.2 by EnergySoft • User Number: 5950 Job Number: C06044
MR SYSTEM REQUIREMENTS Part 1 of 2 MECH-2-C
S
PROJECT NAME DATE
One -Eleven Center 10/4/2006
SYSTEM FEATURES
ITEM OR SYSTEM TAG(S) .
Number of Systems
T-24
MANDATORY MEASURES Section
Heating Equipment Efficiency
Cooling Equipment Efficiency
Heat Pump Thermostat
Furnace Controls
Natural Ventilation
Minimum Ventilation
VAV Minimum Position Control
Demand Control Ventilation
Time Control
Setback and Setup Control
Outdoor Damper Control
Isolation Zones
Pipe Insulation
Duct Insulation
PRESCRIPTIVE MEASURES
Calculated Heating Capacity x 1:43 2
Proposed Heating Capacity 2
Calculated Sensible Cooling Capacity x 1.212
Proposed Sensible Cooling Capacity 2
Fan Control
DP Sensor Location
Supply Pressure Reset (DDC only)
Simultaneous Heat/Cool
Economizer
Heating Air Supply Reset
Cooling Air Supply Reset
Duct Sealing for Prescriptive Compliance
AIR SYSTEMS, Central or Single Zone
Storage ::42
Shop
Retail
2
1
Reference on Plans or Specification 1
112(a)
6.90 HSPF
3.10 COP
3.10 COP
112(aa)
12.0 SEER / 10.7 EER
9.3 EER
9.3 EER
112(b)
Yes
Yes
Yes
112(c), 115(a)
n/a
n/a
n/a
121(b)
No
No
No
121(b)
339 cfm
998 cfm
236 cfm
121(c)
No
No
No
121(c)
No
No
No
121(g), 122(ee)
Programmable Switch
Programmable Switch
Programmable Switch
122(e)
Heating & Cooling Required
Heating & Cooling Required
Heating & Cooling Required
122(0
Gravity
Gravity
Gravity
122(g)
n/a
n/a
n/a
123
124
R-8.0 I
R-8.0
R-8.0
144 (a & b)
n/a
n/a
n/a
144 (a & b) _
56,212 btuh
177,379 btuh
88,689 btuh
144 (a & b)
n/a
n/a
n/a
144 (a & b)
67,701 btuh
217,260 btuh
102,014 btuh
144 (c)
Constant Volume
Constant Volume
Constant Volume
144 (c)
144 (c)
No
No
No
144 (d)
No
No
No
144 (e)
No Economizer
No Economizer
No Economizer
144 (f)
Constant Temp
Constant Temp
Constant Temp
144 (f)
Constant Temp
Constant Temp
Constant Temp
144 (k)
No
No
No
1: For each central and single zone air systems (or group of similar units) fill in the reference to sheet number and/or specification section and paragraph number where the
required features are documented. If a requirement is not applicable, put "N/K in the column.
2: Not required for hydronic heating and cooling. Either enter a value here or put in reference of plans and specificatons per footnote 1.
3: Enter Yes if System is: Constant Volume, Single Zone; Serves < 5,000 sgft; Has > 25% duct in unconditioned space. Duct sealing is required for Prescriptive Compliance,
see PERF-1 for performance method duct sealing requirements.
NOTES TO LD - For Buildina Department Use Only
EnergyPro 4.2 by EnergySoft User Number: 5950 Job Number: C06044 Paae:10 of 15 1
MECHANICAL VENTILATION MECH-3-C
PROJECT NAME DATE
___ One -Eleven Center 1 nIA19nnr%
PRESCRIPTIVE REHEAT
LIMITATION (Section 144(d))
MECHANICAL VENTILATION Section 121 b 2
AREA BASIS
OCCUPANCY BASIS
VAV MINIMUM
A
B
C
D
E
F
G
H
I
J
K
L
M
N
ZONE/SYSTEM
0
Tea
tvo
t'DrDT
-n 3
°0
'.
Q3
x>
nmT
3
z
c
00.
m 0
t7im-n
3
xO3
'fa-n
" m 3
.0+
M
$KA
G)0<
--
D
T'at
3Dto
No
0'
-nn-"
3c
a N
' f°
T
3W
a
a
�n
0S
CD
�00
n x
3
T.
o�
03
D
i
H
D
Storage
2,537
0.15
381
381
339
41
Storage
Total
381
339
Restrooms
92
0.15
14
14
23
Retail
6,503
0.25
1,626
1,626
975
650
Shop
Total
1,640
998
Retail
1,500
0.25
375
375
225
150
Restroom
46
0.15
7
7
12
Retail
Total
382
236
I
C
Minimum ventilation rate per Section 121 Table 121-A
E
Based on fixed seat or the greater of the expected number of occupants and 50 % of the CBC occupant load for egress purposes for spaces without fixed seating.
H
Required Ventilation Air (REO'D V.A. is the larger of the ventilation rates calculated on and AREA or OCCUPANCY BASIS (column D or G).
1
Must be greater than or equal to H, or use Transfer Air (column N) to make up the difference.
J
Design fan supply cfm (Fan CFM) x 30%; or
K
Condition area (ft_sq) x 04 cfm/ft. sq.; or
L
Maximum of Columns H, J, K, or 300 cfm
M
This must be less than or equal to Column L and greater that or equal to the sum of Columns H + N.
N Transfer air must be provided where the Required Ventilation Air (column H) is greater than the Design Minimum Air (column M). Where required, transfer air must be greater than or
equal to the difference between the Required Ventilation Air (column H) and the Design Minimum Air (column M), column H - M.
EnergyPro 1.2 by EnergySoft . User Number 5950 Job Number: C06044 Page 11 of 15
MECHANICAL EQUIPMENT DETAILS
Part 1 of 2 MECH-5-C
PROJECT NAME
One -Eleven Center
DATE 10/4/2006
CHILLER AND TOWER SUMMARY
Efficiency
Tons
PUMPS
Equipment Name
Equipment Type,
Qty.
Tot.
Qty
GPM
BHP
Motor
Eff.
Drive
Eff.
Pump
Control
DHW BOILER SUMMARY
Energy
Factor
or RE
Standby
Loss or
Pilot
TANK INSUL.
System Name
System Type
Distribution Type
Qty
Rated
Input
Vol.
(Gals.)
Condition
Status
Ext.
R-Val.
MULTI -FAMILY CENTRAL WATER HEATING DETAILS
Hot Water Pump Hot Water Piping Length (ft)
Add 1/2"
Control # HP Type* In Plenum Outside Buried Insulation
CENTRAL SYSTEM RATINGS
HEATING COOLING
Aux. Condition
System Name System Type Qty Output kW Eff. Output Efficiency Status Economizer Type
York B1 HH048AO6 Packaged DX 2 45,000 0.0 6.90 HSPF 46,500 12.0 SEER / 10.7 EER New No Economizer
York BP15000OA2/4/5**'**
Packaged DX 3 142,000 0.0 3.10 COP 144,000 9.3 EER New No Economizer
CENTRAL SYSTEM FAN SUMMARY
System Name Fan Type
York B1HH048AO6
Constant Volume
York BP15000OA2/4/5****
Constant Volume
Motor Location
SUPPLY
CFM
FAN
RETURN_FAN
BHP
Motor
Eff.
Drive
Eff.
CFM
BHP
Motor
Eff.
Drive
Eff.
Draw -Through
2,000
0.70
76.0%
100.0%
none
Draw -Through
4,800
3.00
86.5%
100.0%1
none
I EnergyPro 4.2 by Energy Soft User Number: 5950 Job Number: C06044 Paae:12 of 15 1
ENVELOPE MANDATORY MEASURES ENV -
It
PROJECT NAME DATE
One -Eleven Center 10/4/2006
DESCRIPTION
Designer
Enforcement
FX§
118(a)
in Insulating Material shall have been certified by the manufacturer to comply
with the California Quality Standards for insulating material, Title 20, Chapter 4, Article
3
0
§ 118(c)
All Insulating Materials shall be installed in compliance with the flame spread rating
and smoke density requirements of Sections 2602 and.707 of Title 24, Part 2.
0
§ 117(a)
All Exterior Joints and openings in the building that are observable sources of air
-leakage shall be caulked, gasketed, weatherstripped or otherwise sealed.
R
§ 116(b)
Site Constructed Doors, Windows and Skylights shall be caulked between the unit
and the building, and shall be weatherstripped (except for unframed glass doors and
fire doors).
§ 116(a)1 Manufactured Doors and Windows installed shall have air infiltration rates not
exceeding those shown in Table Number 1-E. of the Standards. Manufactured
fenestration products must be labeled for U-value according to NFRC procedures.
X]
§ 118(e)
Demising Walls in Nonresidential Buildings:
The opaque portions of framed demising walls in nonresidential buildings shall have
insulation with an installed R-value of no less than R-13 between framing members.
r
EnergyPro
By EnergySoft User Number: User Job Number: C06044 Page:13 of 15
MECHANICAL MANDATORY MEASURES Part 1 of 2 MECH-MM
NAME
One -Eleven Center
DATE
10/4/2006
DESCRIPTION
Designer
Enforcement
Equipment and Systems Efficiencies
a § 111 Any appliance for which there is a California standard established in the Appliance
Efficiency Regulations will comply with the applicable standard.
§ 115(a) Fan type central furnaces shall not have a pilot light.
❑ § 123 Piping, except that conveying fluids at temperatures between 60 and 105 degrees
Fahrenheit, or within HVAC equipment, shall be insulated in accordance with
` Standards Section 123.
0 § 124 Air handling duct systems shall be installed and insulated in compliance with
Sections 601, 602, 603, 604, and 605 of the 2001 CMC Standards.
Controls
§ 122(e) Each space conditioning system shall be installed with one of the following:
n§ 122(e)1A Each space conditioning system serving building types such as offices and
manufacturing facilities (and all others not explicitly exempt from the requirements
of Section 112 (d)) shall be installed with an automatic time switch with an
accessible manual override that allows operation of the system during off -hours for
up to 4 hours. The time switch shall be capable of programming different
schedules for weekdays and weekends and have program backup capabilities that
prevent the loss of the device's program and time setting for at least 10 hours if
power is interrupted; or
§ 122(e)1 B An occupancy sensor to control the operating period of the system; or
§ 122(e)1C A 4-hour timer that can be manually operated to control the operating period of the
system.
L§ 122(e)2 Each space conditioning system shall be installed with controls that temporarily
restart and temporarily operate the system as required to maintain a setback
heating and/or a setup cooling thermostat setpoint.
§ 122(g) Each space conditioning system serving multiple zones with a combined
conditioned floor area more than 25,000 square feet shall be provided with isolation
zones. Each zone:. shall not exceed 25,060 square feet; shall be provided with
isolation devices, such as valves or dampers, that allow the supply of heating or
cooling to be setback or shut off independently of other isolation areas; and shall
be controlled by a time control device as described above.
0 § 122(a&b) Each space conditioning system shall be controlled by an individual thermostat
that responds to temperature within the zone. Where used to control heating, the
control shall be adjustable down to 55 degrees F or lower. For cooling, the control
shall be adjustable up to 85 degrees F or higher. Where used for both heating and
cooling, the control shall be capable of providing a deadband of at least 5 degrees
F within which the supply of heating and cooling is shut off or reduced to a
minimum.
n§ 122(c) Thermostats shall have numeric setpoints in degrees Fahrenheit (F) and adjustable
setpoint stops accessible only to authorized personnel.
§ 112(b) Heat pumps shall be installed with controls to prevent electric resistance
supplementary heater operation when the heating load can be met by the heat
pump alone.
`
EnergyPro By EnergySoft User Number: User Job Number: C06044 Page:14 of 15
MECHANICAL MANDATORY MEASURES Part 2 of 2 MECH-MM
(PROJECT NAME DATE
One -Eleven Center 10/4/2006
Description -
Designer
Enforcement
Ventilation
❑X
§ 121(e)
Controls shall be provided to allow outside air dampers or devices to be operated at
the ventilation rates as specified on these plans.
§ 122(f)
Gravity or automatic dampers interlocked and closed on fan shutdown shall be
provided on the outside air intakes and discharges of all space conditioning and
exhaust systems.
§ 144(q
All gravity ventilating systems shall be provided with automatic or readily accessible
manually operated dampers in all openings to the outside, except for combustion air
openings.
§ 121(f)1
Air Balancing: The system shall be balanced in accordance with the National
Environmental Balancing Bureau (NEBB) Procedural Standards (1983), or
Associated Air Balance Council (AABC) National Standards (1989); or
a. § 121(f)2
Outside Air Certification: The system shall provide the minimum outside air as
shown on the mechanical drawings, and shall be measured and certified by the
installing licensed C-20 mechanical contractor and certified by (1) the design
mechanical engineer, (2) the installing licenced C-20 mechanical contractor, or (3) the
person with overall responsibility for the design of the ventilation system; or
0
§ 121(f)3
Outside Air Measurement: The system shall be equipped with a calibrated local or
remote device capable of measuring the quantity of outside air on a continuous
<
basis and displaying that quantity on a readily accessible display divice; or
§ 121(f)4
Another method approved by the Commission.
Service Water Heating Systems
§ 113(b)2
If a circulating hot water system is installed, it shall have a control capable of
automatically turning off the circulating pump(s) when hot water is not required.
§ 113(c)
Lavatories in•restrooms of public facilities shall be equipped with controls to limit the
outlet temperature to 110 degrees F.
EnergyPro