Loading...
0011-217 (ELEC)LICENS9D CONTRACTOR DECLARATION I hereby affirm under penalty of perjury that.] am licensed under provi�ions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professionals Code, and my License is. in full force and effect. /Licen e # ;I - . Lic. Class Exp. Date 7 2172 c4s 4 1 awc t I e e Signature of Contractor OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractor's License Law for the following reason: ( ) 1, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or o ffered fo r sale (Sec. 7044, Business & Professionals Code). - . . ( ) 1, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business & Professionals Code). I am exempt under Section B&P.C. for this reason Date Signature of Owner WORktA,s COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: . ( ). I have and will maintain a Certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor,Qode, for,th,e pe ,rfoymance of the work for which this permit -is issued. (X I have and will maintain workers' compensation insurance, as required by Sdcti-on 3700 of the Labor Code, for the performance of the work for which th is permit is issued. My workers' compensation insurance carrier & policy no. are: Carrier Policy No. . WNTIN1,04TAL CA91 (This section need not be completed if the permit valuation is for $100.00 or less). ( ) I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that if I should become s'ubjpet to the workers' compensation provisions of Section 3700 of the Labor Cgde, lish Fer ,,_III fo�egith comply with tl�Iose provisions. - I f�, MI'A' Mate: I I �, ADDlicant— Warning: Failure to secure Workers' Compensation coverage is unlawful and shall subject an employer to criminal penalties and civil fines up to $100,000" in addition to the cost of compensation, damages as provided for in Section 3706 of the Labor Code, interest and attorney's fees. IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the conditions and restrictions set forth on his application. 1. Each person upon whose behalf this application is made & each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this applicaton agrees to, & shall, indemnify & hold harmless the City of La Quinta, its officers, agents and employees. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information i%. correct. -I agree to comply with all City, and State laws relating to the buildinaf c t 6 t'on' and hereby authorize representatives of this City to enter upon onst c' the bove-mentioned prope y for inspection purposes. /ignature (Owner/Agent Date PERMIT# BUILDING PERMIT DATE VALUATION LOT, TRACT .12 JOB SITE APN ADDRESS 78-752-MIGHWAY111 I OWNER CONTRACTOR / DESIGNER / ENGINEER PFF P"X. TR U.Tr PLA-gri-LIM, W107.1 1 14"5) 3LUVEIR 011=1 Wa POMOXA CA. 9 17 61? F, ONTANA CA 92337 (9Q�)82'3-4239. CM4, 4405 USE OF PERMIT LUUMUCAL SIX 1,?LZC;T,;UCA.(, SIONS VOW, SA 2000 ST3 VALUATION 'o.ww"00 1,3 3) C01 �T RSTMATE S*T (O'CONS17RUC. lf)lq 40MMOD YKRWf FM fS[rVMWiY MAN CIMCK FER 101-000-439-318 91,1100 F,LW.rR=AL *FRZ 101-000-420-000 $90.00 KM, -TOTAL 00ROIRTIMTONAND IDLAIR ClUXX $10S.100 UU0 PFYI-PAWY M-03 $0.00 TOTALYMMUFNES)DUS AOW $105,A) DEC' 13 2000 Oi- LA Q 041 DIA2 RECEIP By/ DATEZNALEZD JINSPECTOR _34,b . F : , INSPECTION RECORD OPERATION DATE INSPECTOR OPERATION DATE INSPECTOR BUILDING APPROVALS MECHANICAL APPROVALS Set Backs Underground Ducts Forms & Footings Ducts Slab Grade Return Air Steel Combustion Air Roof Deck Exhaust Fans O.K. to Wrap F.A.U. Framing Compressor Insulation Vents Fireplace P.L. Grills Fireplace T.O. Fans & Controls Party Wall Insulation Condensate Lines Party Wall Firewall Exterior Lath Drywall -Int. Lath Final Final BLOCKWALL APPROVALS POOLS - SPAS steel Set Backs Electric Bond Footings Main Drain Bond Beam Approval to Cover Equipment Location Underground Electric Underground Plbg. Test Final I I Gas Piping PLUMBING APPROVALS Gas Test Electric Final Waste Lines Heater Final Water Piping Plumbing Final Plumbing Top Out Equipment Enclosure Shower Pans O.K for Finish Plaster Sewer Lateral Pool Cover Sewer Connection Encapsulation Gas Piping Gas Test Appliances Final Final Utility Notice (Gas) ELECTRICAL APPROVALS Temp. Power Pole Underground Conduit Rough Wiring Low Voltage Wiring Fixtures Main Service Sub Panels Exterior Receptacles G.F.I. Smoke Detectors Temp. Use of Power Final Utility Notice (Perm) COMMENTS: 11/21/2000 15:15 19098232013 PLASTI LINE WEST t y 3 Plash -Line .Wes$ A Division of Plasti-Line, Inc. 13489 Slaver Building 8 Fontana, California 92337 Tel. (909) 823-1239 Fax.. (909) 823-2013 11/22/00 To: Whom it may concern, From: Scott Martin; Plasti-Line, West Regarding: Sign artwork for PFF Bank & Trust, 78-752 Highway 111, La Quinta In regards to the drawings (00-735 pages 1through 5) created by Plasti-Line.. West, for PFF Bank & Trust, it is important to note these raceways will be manufactured for a behind the wall application only, and will not be visible on the elevations, froze the exterior of the building. Thank you, Scott,Martin Field ,Activities Manager Plasti-Line, West PAGE 02/02 Eq � 10'-611 Ea I T-0" r .................. Time and Temperature display Height: 1.75 Lineal feet Length: 5.38 Lineal feet �1 1• ea I i 1 _';int,) PFFi B� IT ' 1 '�TrRILI ■ East Elevation 5cale:1/8"=1'-0" Time and Temperature dis laV Height: 1.75 Lineal feet Length: 5.38 Lineal feet West Elevation 5cale:1/8"=1'-0" APP'R(3 /tW b1( MMUNITY DEVELOPMENT DEPARTMENT 8Y — DATE EXHIBIT CASE N0."- 4,41 ilk CITY OF LA QUINTA BUILDING & SAFETY DEPT. APPROVED FOR CONSTRUCTION 7ATF �1 2'�- aU BY Production Setup: Neon O Vinyl O Router O Former O Outsource O PLW Engineering Dwg: Yes O No O Knox. Engineering Dwg: Yes O No O i71 0 P®ast� Una West In Nate, pons is drawing ale Indicated an this drlwlnq an DO NOT MANUFACTURE UfaE wrrHDUT REQUIRED APPROVALS O ALL OF TXa a01tEa6lLOw YUST BE naTLLLFD AND GATED iPoOR TO UANIlIALTUWNO ProJDct PFF Bank iQ9/15/00 ER Q0118/00 ER Drawing No. A Division of Plasti-Line Inc. copyPlast na, I and owned by and shallbnot repro 00-735A7 Drawing Approved by hili8lS Dae Location La Quinta CA Q2 9/21/00 ER ®11/14/00 ER rbe be ce reproduced, used by or disclosed to any person, firm or corporation for any purpose whatsoever � 13489 Stover, Building B, Fontana, California 92337 Sales Approval to Mfr Date n/1 1 /oo 7 ,.a PLW Rep. It Aal Lin IV' Drawn by RDmO . O9/21/00 ER e11/20/00 ER (909) 823-1239 Fax. (909) 823-2013 without written Or �e e& �"°''"` , Sheet 1 of 5 Production Approval to Mfr CllentApprovaJ Date of Approval ®g/28/0 EK ® E 1 25'-0„ 24' ED o a o 0 � a t + 1 0 t LD Ell Eck North Elevation 5cale: 1/8"=1'0" F-C-ITY OF LA OUINTA ` PSI' .DING & SAFETY DEPT. 0, V E D FOR �_-ONSTRUCTION l South Elevation 5cale:1/8" =1'-0" Production Setup: Neon O Vinyl O Router. O Former O Outsource O PLW Engineering Dwg:. Yes O No O Knox. Engineering Dwg: Yes O No O ® plant® Llne ����Ali lndka m plans or rangemenre 4fdkerea M afW drawing ef0 DO NOT MArIUFACTURE"T"MA1WITHOUT OATEDM REQUIREDAPPROVALSprom:. ALL OF TIM Bmi9BELOW WIST BE UaiUlEe u.D OATE�P�i1Gi1 TO YANUFACR:FI:Ja PFF Bank t&9/15/00 ER 10/18/00 Q ER Drawing No. A Division of Plastl-Une, Inc. copyrighted I ena owned by ;;'rte ; ed.°"used by o; disclosed to any person, firm at corporation for any purpose whatsoever without written ®®-735 D Drawing Approved by Initials Dale LocaIlon La QUinta, CA &9/21/00 ER' &11/14/00 ER 13489 Stover, Building B, Fontana, Calilomia 92337 Sales Approval to Mfr Dato 9/11 /00 PLW Rap. Martin Drawn by Romo a 9/21/00 0 ER e11/20/00 EP. (909) 823-1239 Fax. (909) 823-2013 permission na. Wast. �""°' Inc.Production Sheet 2 of Approval to Mfr Client Approval Date of Approval &,9/26/01 ER Q JI 5 25'-011 24'-2" Raceway 24" t. � � LD N 81/= LD N 5cale:1/2" =1'-0" ® Fab. alum. letter � ©Trim cap Mfr. & Insatll: 5° 8° ®Acrylic face (2) Two Sets of Internally Illuminated Pan Channel Letters: ® Neon tube ® 1/2" Chase nipple w/lock ring Returns p Pop rivets Trim Ca Fabricated Aluminum, 5" deep, finish Blocl tng p ®End cap over electrode Dark Blue TM 3630-137 1/4" White Outlin Drain hole 1/4" Dark Blue Outline Faces I 81/2' ® 5hort Sleeve over electrode White Acrylic 7328 with 1/4" Dark Blue 3630-137 m GTO sleeving Fac outline . ®Raceway w/C channel frame Trite: ® GFI Neon transformer 1" Blue painted TM 3630-137 ® 2" x 2" x 1/4" stl angle Actual Size ® Mounting hardware as rej'd . Illumination 0 (see Chart) 15mm, 6500 White neon, 30ma, CITY OF LA QUINTA I ���,��;AA ® Glass stand remote GFI transformers SAFE i Y DEPT. ��;N"'' l BUILDING & ±of Raceway, '�APpROVED Fab. .063 Alum., 81/2"h x 8"d,FOR CONSTRUCTION j paint TM bldg )ATE BY— MI", Y -- F - r 1. Production Setup: Neon ❑ Vinyl ❑ Router ❑ Former ❑ Outsource ❑ PLW Engineering Dwg: Yes ❑ No ❑ Knox. Engineering Dwg: Yes ❑ No ❑ JMMM= ® P/�st� �0�� ���� AllIdeas.an EN emngng are Indicated on ENS drawing are DD NOT OMS SEL CTU REWRHDUTREDUIREDAPPROVALS � OF nm edxee atavw oust eE vetwto eva an:o rwce ro uewr:Aeruwr:o prosect PFF Bank &9/15/00 ER ®10/18/00 ER Drawing o. s ' A Ditrision of Plasfl-Line Inc. copyrighted and owned by p'�"""°� Inc. °"d °""" "°` di reproduced, used by o< dtsctosed to any poreon, ttrm or corporation tar any Wrp080 whatsoever oo 7 Q 35 Drawing Approved by INtia1S Dale _ L��on La Quinta CA ©9/21/00 ER ©11/14/00 ER 13489 Stover, Building B, Fontana, California 92337 Sales Approval to Mir Dato 9/11/00 . PLW Rep. Martin Df awn by Romo ©9/21/00 EK 811/20/00 ER (909) 823-1239 ' Fax: (909) 823-2013 without written a otesd-Une, VYo"�'"°' "` Sheet 5 of 5 Production Approval to Mir clt2rt Approval Date of Approval ®9/2B/O EK ® r 5ca le: 3/8" =1'-0" „ �r 1/2" 12" O Fab. alum. letter 0 Trim cap 0 Acrylic face 0 Neon tube ® 1/2" Chase nipple w/lock ring 0 Pop rivets O End cap over electrode 0 Drain hole 0 Short sleeve over electrode 0 GTO sleeving m Raceway w/C channel frame ® GFI Neon transformer 0 2" x 2" x 1/4" stl angle ® Mounting hardware as regi! (See Chart) Q Glass stand Production Setup: Neon O M 10'-6" T-0" 10' Raceway Trim C 1/4" White Outl 1/4" Dark Blue Outli Fa T 1/2" 181/2" 5hield. CITY OF LA QUINTA Parkblue3630-137 BUILDING &SAFETY DEPT. "PFF" io White diffuser 3635-70 APPROVED Bank & Trust (Individual pan channel letters) FOR CONSTRUCTION K turns: r - DATE BY ---Fabricated aluminum, 5" deep, finish Dark Blue 3630-137 Mfr. & Install: (1) One Set of Internally Illuminated Letters and Logo akgd: (Logo) Fabricated #4 brushed finish Stainless Steel face and returne(13"d). Laser cut graphics and thru 3/4" thick Clear acrylic with polished edges. Overlay Clear faces with vinyl as noted: Chevrons: Top: Sultan Blue 3630-157 Middle: Bright Blue 3630-167 Bottom: Light European Blue 3630-147 Actual Size NST g gu?li�zl�� Vinyl ❑ Router ❑ Former ❑ Outsource O PLW Engineering Dwg: Yes ❑ No O Faces: White acrylic 7328 with 1/4" Darrk Blue 3630-137, outline Trim Cap: 3/4" Blue painted TM 3630-137 Illumination 5T,15mm, 6500 White neon, 30ma, remote GFI transformers Raceway Fab. .063 Alum., 81/2"h x 8"d, paint TM bldg Knox. Engineering Dwg: Yes 0 No O ®�� ©��t���' ��� And IIdeas.ndic" pram i edrav& am dndrated on drawled we DO NOT MANUFACTURE WITHOUT REQUIRED APPROVALS �ofTMsemEaeFloweauereEuaruuao oarcocaonro run m PrOl PFF Bank Q9/15/00 ER 10/18/00 © ER Drawing No. A Division of Plasf!-Line, Inc. an eopyrld a. I and owned by bee rep," d use snail "a disclosed to any person. Mo or corporation for any purpose whatsoevar without written ®® 735 D Drawing Approved by InilielS Date Dale Location La Quinta, CA 209/21/00 EK ®11/14/00 EK 13489 Stover, Building B, Fontana, California 92337 Sales Approval to Mfr onto 9/11/00 ..a PL6V Rep. Martin °ram Romo 09/21/00 ER e11/20/00 ER (909) 823-1239 Fax. (909) 823-2013 a°MastWn4„�"�" °' Inc. Sheet 4 of 5 Production Approval to Mtr Client Approval Date o1 Approval ®9/28/0 EK Oe 50a l e: 3/8" =1'-0" cri t 10'-6" 6'-0" 10' Raceway Trirr 1/4" White 0 1/4" Dark Blue Ou Mfr. & Install: (1) One Set of Internally Illuminated Letters and Logo Bkad: (Logo) Fabricated #4 brushed finish Stainless Steel face and returns (13"61). Laser out graphics and thru 3/4" thick Clear acrylic with polished edges. Overlay Clear faces with vinyl ae noted: Chevrons: Top: Sultan Blue 3630-157 Middle: Bright Blue 3630-167 Bottom: Light European Blue 3630-147 Shield: 1151/2 Dark Blue 3630-137 "PFF" is White diffuser 3635-70 Production Setup: - Neon 0 Vinyl 0 Router 0 Former 0 Outsource 0 Actual size PLW Engineering Dwg: Yes 0 No 0 Bank & Trust (Individual pan channel letters) Returns: Fabricated aluminum, 5" deep, finish Dark Blue 3630-137 Faces: White acrylic 7328 with 1/4" Dark Blue 3630-137 outline Trim Cap: 3/4" Blue painted TM 3630-137 Illumination 5T,15mm, 6500 White neon, 30ma, remote GFI transformers Raceway Fab. -063 Alum., 81/2"h x 8"d, paint TM bldg Knox. Engineering Dwg: Yes 0 No 0 f CITY OF LA QUINTA BUILDING & SAFETY DEPT I APPROVED FOR CONSTRUCTION DATE BY I Plast® Line' WestAD - 0 Fab. alum. letter DO NOT MA3aEUDW MEwRHOII)OAPEO RED APPROVALS •u OF THE 60727 OEI.OW 1NSf BE IW TL4EO ND orTEO PAIOA TO LWt1:LACNILNO ® Trim cap 5' 1 8" ©10/18/00 0 Acrylic face Drawing No. A Division of Plast!-Une Inc. r copyrighted Inc. and owned by Pe repro ceand us shall not be reproduced, used by or disclosed to any person. firm �n corporation porat°n fw a purposeitten 0 Neon tube Drawing Approved by �1i81S 0 1/2" Chase nipple w/lock ring LOt:a[IOn La Quints CA 02 9/21/00 Blocking ® Pop rivets ®11/14/00 EK 0 End cap over electrode Sales Approval to Mfr 0 Drain hole Date 9/1 1 /00 Plw Rep. Martin 0 Short sleeve over electrode Q9/21/00 ERper 81/2" ® GTO sleeving ER (909) 823-1239 Fax: (909) 823-2013 m Raceway w/C channel frame Sheet 5 5 Production Approval to Mfr 0 GFI Neon transformer �-� Client Approval Date of Approval ® 2" x 2" x 1/4" stl angle Qe ® Mounting hardware as read n (see Chart) Glass stand i,U z A LIT u y S= g1 4+.t -m fit l ��N 4 10' Raceway Trirr 1/4" White 0 1/4" Dark Blue Ou Mfr. & Install: (1) One Set of Internally Illuminated Letters and Logo Bkad: (Logo) Fabricated #4 brushed finish Stainless Steel face and returns (13"61). Laser out graphics and thru 3/4" thick Clear acrylic with polished edges. Overlay Clear faces with vinyl ae noted: Chevrons: Top: Sultan Blue 3630-157 Middle: Bright Blue 3630-167 Bottom: Light European Blue 3630-147 Shield: 1151/2 Dark Blue 3630-137 "PFF" is White diffuser 3635-70 Production Setup: - Neon 0 Vinyl 0 Router 0 Former 0 Outsource 0 Actual size PLW Engineering Dwg: Yes 0 No 0 Bank & Trust (Individual pan channel letters) Returns: Fabricated aluminum, 5" deep, finish Dark Blue 3630-137 Faces: White acrylic 7328 with 1/4" Dark Blue 3630-137 outline Trim Cap: 3/4" Blue painted TM 3630-137 Illumination 5T,15mm, 6500 White neon, 30ma, remote GFI transformers Raceway Fab. -063 Alum., 81/2"h x 8"d, paint TM bldg Knox. Engineering Dwg: Yes 0 No 0 f CITY OF LA QUINTA BUILDING & SAFETY DEPT I APPROVED FOR CONSTRUCTION DATE BY I Plast® Line' WestAD - Indkat°, an this or lodxated on Nb drawlnq are DO NOT MA3aEUDW MEwRHOII)OAPEO RED APPROVALS •u OF THE 60727 OEI.OW 1NSf BE IW TL4EO ND orTEO PAIOA TO LWt1:LACNILNO Protect PFF Bank Q9/15/00 EK ©10/18/00 EK Drawing No. A Division of Plast!-Une Inc. r copyrighted Inc. and owned by Pe repro ceand us shall not be reproduced, used by or disclosed to any person. firm �n corporation porat°n fw a purposeitten 00-735 Drawing Approved by �1i81S Date LOt:a[IOn La Quints CA 02 9/21/00 EK ®11/14/00 EK 13489 Stover, Building B, Fontana, California 92337 Sales Approval to Mfr Date 9/1 1 /00 Plw Rep. Martin °raver by Romo Q9/21/00 ERper 811/20/00 ER (909) 823-1239 Fax: (909) 823-2013 orr pW0- 1y:11 1U`1 ' " Sheet 5 5 Production Approval to Mfr Client Approval Date of Approval &9/25/01AEK Qe of