Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
BCOM2015-0043
78-495 CALLE TAMPICO D VOICE (760) 777-7125 LA QUINTA, CALIFORNIA 92253 FAX (760) 777-7011COMMUNITY DEVELOPMENT DEPARTMENT INSPECTIONS (760) 777-7153 BUILDING PERMIT Date: 8/14/2015 1 -Application Number: BCOM2015-0043 Owner: Property Address: 78805 HIGHWAY 111 WM LA QUINTA APN: 643020043 80618 DECLARATION AVE Application Description: ONE NEW ATM & PREP FOR ONE FUTURE ATM INDIO, CA 92253 Property Zoning: Application Valuation: $33,552.00 Applicant: FRY CONSTRUCTION CO, INC., CE OUTSIDE CITY LIMITS LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, and my License is in full force and effect. License Class: _ License No.: :LIC -0003995 y� i�t : O's -1 / �' Contractor:` i OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: (_) I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). (_) I, as owner of the property, am exclusively contracting with licensed contractors to construct the project. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). ( I I am exempt under Sec. . B.&P.C. for this reason Date: Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Na Lender's Add Contractor: FRY CONSTRUCTION CO, INC.; CE OUTSIDE CITY LIMITS (909)920-5020 Llc. No.: :LIC -0003995 WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. I have and will maintain workers' compensation insurance, as required by . Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier:— Polity Number: I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, if I should become subject to the workers' compensation provisions of Section 3700 of the Lab r Code, I shall forthwith comply with those provisions. Date: 0O' I -1 " 1 Applicant: WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT: Application is hereby made to the Building Official for a permit subject to the conditions and restrictions set forth on this application. 1. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application , the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its offices, agents, and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter upo a above- mentioned property for inspection purposes. Date: Q?1— I `9 — I) Signature (Applicant or Agent) DESCRIPTION FINANCIAL INFORMATION ACCOUNT QTY AMOUNT : 'PAID PAID DATE BSAS SB1473 FEE 101-0000-20306 0 $2.00 $0.00 PAID BY, METHOD RECEIPT # CHECK # CLTD BY Total'Paid forBUILDING STANDARDS 'ADMINISTRATION BSA '$2.00 $0.00 DESCRIPTION ACCOUNT.. QTY AMOUNT PAID PAID DATE FIXTURES, FIRST 20 101-0000-42403 1 $24.17 $0.00 PAID BY, - ' METHOD.: RECEIPT -4 CHECK # CLTD BY DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE FIXTURES, FIRST 20 PC 101-0000-42600 1 $24.17 $0.00 PAID BY METHOD RECEIPT # CHECK # CLTD BY Total Paid for ELECTRICAL: $48.34 $0.00 DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE REMODEL, FIRST 100 SF 101-0000-42400 0 $49.31 $0.00 PAID BY METHOD RECEIPT# CHECK# CLTD BY DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE REMODEL, FIRST 500 SF PC 101-0000-42600 0 $134.88 $0.00 PAID BY METHOD RECEIPT # CHECK # CLTD BY Total Paid for REMODEL: $184.19 $0.00 TOTALS:00 Description: ONE NEW ATM & PREP FOR ONE FUTURE ATM ADDITIONAL Type: BUILDING, COMMERCIAL Subtype:. REMODEL Status: APPROVED Applied: 8/3/2015 PJU Approved: 8/13/2015 JJO Parcel No: 643020043 Site Address: 78805 HIGHWAY 111 LA QUINTA,CA 92253 Subdivision: TR 32683 Block: Lot: 43 Issued: Lot Sq Ft: 0 Building Sq Ft: 0 Zoning: Finaled: Valuation: $33,552.00 Occupancy Type: Construction Type: Expired: No. Buildings: 0 No. Stories: 0 No. Unites: 0 ONE WEEK LIST PER JIMMY. Details: INSTALL ONE NEW eATM AND PREP FOR ONE (1) FUTURE eATM Printed: Friday, August 14, 2015 9:57:05 AM 1 of 2 (CR SYSTEiMS ADDITIONAL CHRONOLOGY CHRONOLOGY TYPE STAFF NAME ACTION DATE COMPLETION DATE NOTES PLAN CHECK SUBMITTAL PHILIP JUAREZ 8/3/2015 8/3/2015 ONE WEEK LIST PER JIMMY. RECEIVED T TELEPHONE CALL JIM JOHNSON 8/13/2015 8/13/2015 CALLED ERNESTO TO INFORM HIM PLANS ARE READY TO ISSUE CONDITIONS CONTACTS NAME TYPE NAME ADDRESSI CITY STATE ZIP PHONE FAX EMAIL APPLICANT FRY CONSTRUCTION CO, INC., CE OUTSIDE CITY LIMITS (909)920-5020 CONTRACTOR FRY CONSTRUCTION CO, INC., CE OUTSIDE CITY LIMITS (909)920-5020 OWNER WM LA QUINTA 80618 DECLARATION INDIO CA 92253 (909)920-5020 AVE Printed: Friday, August 14, 2015 9:57:05 AM 1 of 2 (CR SYSTEiMS Printed: Friday, August 14, 2015 9:57:05 AM 2 of 2 SYSTEMS FINANCIAL INFORMATION ......,,, CLTD DESCRIPTION ACCOUNT CITY AMOUNT PAID PAID DATE RECEIPT # CHECK # METHOD PAID BY BY BSAS 561473 FEE 101-0000-20306 0 $2.00 $0.00 Total Paid forBUILDING STANDARDS ADMINISTRATION .$2.00 $0.00 BSA:- SA:-FIXTURES, FIXTURES,FIRST 20 101-0000-42403 1 $24.17 $0.00 FIXTURES, FIRST 20 PC 101-0000-42600 1 $24.17 $0.00 Total Paid forELECTRICAL: $48.34 $0.00 REMODEL, FIRST 100 SF 101-0000-42400 0 $49.31 $0.00 REMODEL, FIRST 500 SF 101-0000-42600 0 $134.88 $0.00 PC Total Paid forREMODEL: $184.19 $0.00 TOTALS: $234.53 00 Printed: Friday, August 14, 2015 9:57:05 AM 2 of 2 SYSTEMS Bin # Qty of La Quinta Building 8r Safety Division l,Q P.O. Box 1504, 78-495 Calle Tampico �� La Quinta, CA 92253 - (760) 777-7012 Building Permit Application and Tracking Sheet Permit # �1 ct�� Project Address: 78805 Hwy 111 La Quinta, CA.92253 Owner's Name: JP Morgan Chase Bank A. P. Number: Address: Legal Description: CHASE Bank City, ST, Zip: L9 7-215• 7 Contractor: C.E. Fry Construction, Inc. • FI)v'h`;:jb ^:i:iit!yq•�ni�J• •.nl.). Telephone: :?;•vlk):s: Project Description: Address: 286 Corporate Way City, ST, Zip: Upland, CA 91786 Install One (1) New eATM and Prep for One (1) future. (909) 920-5015 City Lic. # eATMTelePhone: State Lic. # : 299051 B Arch., Engr., Designer: Address: City., ST, Zip: Telephone: State Lic. #: Construction Type: Occupancy: Project type (circle one): New Add'n Alter Repair Demo Name of Contact Person: _ il �� Sq. Ft.: # Stories: #Units.. Telephone # of Contact Person: 010 q ZO - SO IS Estimated Value of Project: S . APPLICANT: DO NOT WRITE BELOW THIS LINE # Submittal Req'd Recd TRACKING PERMIT FEES Plan Sets Plan Check submitted Item Amount Structural Calcs Reviewed, ready for corrections Plan Check Deposit Truss Calcs. Called Contact Person Plan Check Balance Title 24 Calcs. Plans picked up Construction Flood plain plan Plans resubmitted Mechanical Grading plan 2'" Review, ready for corrections/issue Electrical Subcontactor List Called Contact Person Plumbing Grant Deed Plans picked up S.M.I. H.O.A. Approval Plans resubmitted Grading IN HOUSE:- '"' Review, ready for corrections/issue Developer Impact Fee Planning Approval Called Contact Person A.I.P.P. Pub. Wks. Appr Date of permit issue School Fees Total Permit Fees q. OF eATM & TELLER WDW EXIST. TELLER EXIST. TELLER MILLWORK OR MILLWORK OR ® o WALL BEHIND - WALL BEHIND - a VERIFY IN FIELD o VERIFY IN FIELD ® cl) eATM CENTER oil Ln CORE UNIT TRIM KIT TRIM KIT v _ N 0 0 0 eATM OPTIONAL eATM ELEC & DATA rn SIDE CARS CONNECTIONS iv Ir 4 II TRIM KIT BEHIND REAR ELEVATION SIDE ELEVATION FRONT ELEVATION — (1) DUPLEX ELEC. OUTLET, (1) EXIST. TELLER MILLWORK OR WALL Ev— SINGLE-PORT DATA OUTLET BEHIND - VERIFY IN FIELD S AND (1) SECURITY TERMINAL — ________.._Y__. - - CONCEAL CONNECTIONS — — _— — —_ — 1 — -- ON K 9 LOCATE eATM v3.0 ADJACENT TO USE EXIST. TELLER LINECl TELLER MILLWORK OR WALL - 6'-10" RACEWAY WHERE POSSIBLE .5 1 1 1 REFER TO DETAILS FOR ADDL. INFO. AFF I I I WALL-MOUNT eATM J M SECURITY KEYPAD (#9) r 0� eATM CENTER CORE UNIT ml IMMEDIATELY ADJACENT TO PERIMETER KEYPAD (#2) I r-1IeATM OPTIONAL SIDE CARS r�l PROVIDE BLUE PENDANT LIGHT ' 1 FIXTURE ABOVE eATM WHERE eATM IS INSTALLED ADJACENT TO I „I J 9 j WALL BEHIND ONLY 1 111 513/4 CAMERA(S) AT 9'-0' AFF CAPTURING q OF eATM & ` W eATM VAULTS & CUSTOMERS L TELLER WDW DATA/ ELEC. PLAN — _ 4 eATM'V ! �iJ L QUINTA $A �R2.5 1/4" =1'-0" 2 I i���� DEPT, VED FOR CONST DESIGN STANDARD DAT 03.141 DES G R AR ALE A /4' =1'-0' CHAS EO eATM v3.0 RDC 15-002-R1_Page 4 of 11 0 V 2' 4' 8' 7 I R2.5 518' FLEXIBLE FILLER ADHERED TO (3) EDGES OF MDF ENCLOSURE ABUTTING eATM (EPDM CELLULAR RUBBER WEATHER STRIP OR EQ.) EXIST. TELLER MILLWORK - VERIFY IN FIELD 314' BLACK MELAMINE ENCLOSURE - COORD. DEPTH SO THAT eATM CLEARS FARTHEST TELLER MILLWORK PROJECTION 4•4 DIA. OPG. THRU TELLER MILLWORK WALL TO ACCOMMODATE ELEC. I DATA CONNECTIONS - COORD LOCATION wl EXIST. RACEWAY VERIFY LOCATION OF EXIST. ELEC I DATA RACEWAY IN FIELD v3.0 TRIM KIT - SECTION 1/2" = 1'-0" 4 OF eATM 8 TELLER WDW r— ---I i � I --------- --- T IR2.5 4'«/. DIA OPG. THRU TELLER V.0. MILLWORK WALL TO ACCOMMODATE ELEC./DATA CONNECTIONS - COORD. - LOCATION w/ EXIST. RACEWAY OUTLINE OF eATM BEYOND ' 3/4' BLACK THERMALLY -FUSED - MELAMINE ENCLOSURE w/REMOVABLE TOP (SCREW TO SIDE PANELS) 4'i/- DIA. OPG. THRU TELLER MILLWORK WALL TO ACCOMMODATE ELEC. / DATA CONNECTIONS - COORD. LOCATION w/ EXIST. RACEWAY CONT. 2z BLOCKING AT FACE OF. MILLWORK TO SUPPORT SIDE PANELS WHEN TOP REMOVED -CONCEAL ALL FASTENERS eATM ELEC./DATA RECEPTACLES - VERIFY LOCATION IN FIELD _ TELLER LINE COUNTERTOP ABOVE 1 eATM 1 v3.0 I 1 I 5/8' FLEXIBLE FILLER ADHERED TO (3) 1 1 1 EDGES OF MELAMINE ENCLOSURE ABUTTING eATM (EPDM CELLULAR RUBBER WEATHER STRIP OR EQ.) I 1 1 I CONCEAL eATM ELEC! DATA/ I 1 1 I SECURITY WIRING . 773 14 Y TELLER WOW QUINTA 6 v3.0 TRIM KIT - SECTION 5 v3.0 TRIM I�� FET}DEPT 1/2 = 1'-01/2°=1'-0�RFOR coNs�® rRucr,ON DESIGN STANDARD R4VAIJ DESIGNER AREA SCALE HASEO eATM v3.0 TRIM KIT DETAILS os. va° _ 11-01 RDC 15-002-R1_Page 5 of 11 0 1' 7 4' 8' v y O I CD Chapter3. Installation Information WkIaWion Manual Height and Depth Main Fascia Items Z p ® p 111 ► The following pictures and tables give the height and depth to the mai Qi�jt;;SD located on the fascia.Q ®� m oZS Z That satisfies the ADA standard 8nd.allows good accessibility and cor v&4ier f rr O both of unhandicapped and handicapped people. O Z(L � Q J 0 � G LU . B m Q E F -JHD Unit COIN SPR ERP/CCR. CCIM Symbol A B C D Height 17.58inch (446.5mm) 39.12inch (993.6mm) 33.47inch (850.2mm) 30.86inch (783.9mm) Depth from Front Shelf 4.86inch (123.5mm) 8.95inch (227.5mm) 3.05inch (77.4mm). 3.68inch) (93.5mm) Unit BRM MCU OPL Symbol E F G Height 34.07inch (865.4mm) . 38.73inch (983.1mm) 60.56inch (1538.2mm) Depth from Front Shelf 8.91 inch (226.3mm) 8.48inch (215.3mm) 15.89inch (403.6mm) Chapter3. Installation Information Recommenaea instaiiation ana service clearance I"" UL- U0,z o®o ► Following diagram is describing the recommended areas required for in 3tMD U Servicing the ATM. (Areal View) 0 W > � Q } ® m [nCO Z 19.68inch (500.Omm) 47.04inch (1194.9mm) 19.68inch (600.0i UL 06 O 1.97inch 41.73inch (1060.Omm) U ®Z (50.Omm) . F Cr. E LJ. W CO Q E 0 � o N � u c w' n � t v c'DI 86.41inch (2194.9mm) 3-6 © 2014 Nautilus Hyosung Inc. All Rights Reserved. NAUTILl1S.' HY-O,. NU ` RDC 15-002-R1_Page 9 of 11 Installation Manual Chapter3. Installs i .CF_ ► Following diagram is describing the recommended areas required for installing arm U I.— servicing servicing the ATM. (Side View) C) � �.U)0 m 47.59inch (1208.8mm) LL. °d Z O 13.13inch (333.6mm) Q z 0 EL - �o W Q o o ...E E E of Ch � o> • L t V .V C C Cf in r CD n :C4 o - : NAUTILUS HYOSUNG © 2014 Nautilus Hyosung Inc. All Rights Reserved. 3-7 RDC 15-002-R1_Page 10 of 11 Installation Manual Chapters. Required for the Chapter5. Requirement for the floor and Anchoring Bolting Down the MX8200OT rj�Anchoring C3 LU U Q> CC m crz LL O ► To bolt down the MX82000T using the Anchor Bolt Location Sheet (templ e0# 9`tQ following steps: 1. Ensure that the surface where the MX82000T is to be placed is level s jL,]L. ft t attl�d tl not tip over when opening the upper/lower modules or the door. rterm Q Place 2. the anchor bolt location sheet where the MX82000T is to be insta IJP 3. Drill the correct diameter and depth holes at the locations marked on the ee . 4. With the groove of the anchor bolt facing up, drive the anchors into the holes drilled in step 3. 5. Place the MX82000T on the bolt location sheet, matching the mounting holes of the unit with the anchors. 6. Firmly tighten the mounting bolts in the anchors. ► Anchor bolts location sheet sample 41.73inch (1060.0mm) 30.87inch (784.0mm) 6.22inch (1151 I.Ornni) 14.57inch (370..Omm) 13.58inch (345.0mm) _ E E BACK o n � ------ Anchor hole s oz0.0 co ..m E E E E L CD C C L U I ' c U C I rknchor Setting N i 1. Makf 8. anchor holes. I 2. Place. the ATM machine over the fixed, labI so that onchor'holes ling rup acc�rding to the, picture. - ------------------- -=---- FRONT 4NA'UTILUS HYOSUN.G © 2014 Nautilus Hyosung Inc. All Rights Reserved. 5-1 RDC 15-002-R1—Page 11 of 11' k . CITY Of ' COMMUNIr Ld Ql.11lltd CHASE0,, RETAIL DISTRIBUTION NET WOfRE�TI®NFEE OF '.L . 78805 Hwy 11, La Quinta, CA 92253 BE CHARGED IF THE APPROVEDi^Iq DND Numher 10389 IS AND 10B CARL ARE NOT ON 'AIM �R A SCHEpUtEp CFPTIONSI RM Approval . TLT Incremental Equipment .Partner Staffing End -State Staffing "*"' ° Name - -Market Quad EndState Teller # of # of DU. # of # of eATM. #of II FA PCA. IA MB RM Total PBs RBs PCBs Bankers ABM ABM ��Ap�� g� BQ �Ct�t Molal eATMs ATMs CR's Tablets 1, U_ REUSED /RELOCMfgD- & S^F Ty P"OVED��� � 11 C NEW MILLWORK vSTRf T1 Sales Ops a e9e Windows AUG 03 2015 �t La �uinta Inland Empire 1 - 1.0 9 �R A SCHEpUtEp CFPTIONSI RM Approval . DATE 4 m on the following Code Holidays: t5 SCCR6 CCR9 AST. 5 "*"' ° LN EN%o E I, President's Day Memorial Day Independence Day SCCR? CCR1 SCTnt"I Labor Day Veteran's Day 0 Thanksgiving Day ® EXISTING TO BE REMOVED Christmas Day CSC LEGEND: s1 EXISTING TO BE REMOVED EXISTING FURNITURE REUSED RELOCATED 1, U_ REUSED /RELOCMfgD- & S^F Ty P"OVED��� � 11 C NEW MILLWORK vSTRf T1 DESIGNER: SC/KC 2015-07-08 �- AUG 03 2015 �t 9 O FOLD CITY OF LA QUINTA COMMUNITY DEVELOPMENT ® ; �oFFlce . ® °. 1DEQUATELY SIZED DEBRIS CONTAINER DOCUMENTS I LON ° OFFI E � OF ICE REQUIRED ON THE JOB SITE DURING ALL to 1 W 9 E BASES OF CONSTRUCTION AND MUST BE '^ its )f 50 --, a ..FTSED AS NECESSARY. FAILURE TO DO SO V oe 2" )f 50 ... — ' --' °- _. "FA COt �N F MST Q-= _.a _- „CA� SSE TI HE C TY TO HAVE THE CONTAIN jw�IiPED AT THE EXPENSE OF THE OWNER/ :"RACTOR." ® C7) 1HOUM SCCR 2 C Q r 1st - April 30 y - Friday: 7:00 a.m. to 5:30 jom. Saturday: 8:00 a.m. to 5:00 P.M. Sunday: Ione Government c^ d - e Holidays: ®n ,, EXISTING Nzaylst-Sep,,,,gnber30tiPROPOSED S, F. ,s• lea©-a:ay - Fn � .ry: 6:00 a.m. to 7:00-OP441 S.F. Satu-relay: 8:00 a.m. to 5:00 p.m. Sunday: Norne FLOOR PLANS fgoveranment Code Holidays: bone Confidential. JPMorgan Chase Bank, N.A. Proprietary Information. ��--F__;--- AT 4 T i Construction is NOT PERMITTED 4 m on the following Code Holidays: t5 SCCR6 CCR9 AST. 5 New Year's Day LN Dr. Martin Luther King JOY President's Day Memorial Day Independence Day SCCR? CCR1 SCTnt"I Labor Day Veteran's Day 0 Thanksgiving Day ® EXISTING TO BE REMOVED Christmas Day CSC LEGEND: y � EXISTING TO BE REMOVED EXISTING FURNITURE REUSED RELOCATED B3�LA A �'� EXISTING FURNI7~11R1 P� 1()r1`JLj NET NEW NEW SIGNAGE/MARKETINGFUTURE REUSED /RELOCMfgD- & S^F Ty P"OVED��� PATH OF TRAVEL eATM SIGNAGE PANEL L NEW BORDER TILE j� }� CON NEW MILLWORK vSTRf T1 DESIGNER: SC/KC 2015-07-08 �- La Quintd CHASE O RETAIL DISTRIBUTION NETWORK 78805 Hwy 11, La Quinta, CA 92253 DND Number 10389 0 Y 4' 8' 76' DEMOLITION PLAN Confidential. JPMorgan Chase Bank, N.A. Proprietary Information. DEMOLITION GENERAL NOTES A o. WORK IN BLUE. - - B. FURNITURE VENDOR IS TO BE RESPONSIBLE FOR ALL FURNITURE THAT IS REMOVED AND / OR RELOCATED. GENERAL CONTRACTOR (GC) AND . [SUPERVISOR (PROJECT MANAGEMENT)) (SPM) ARE TO COORDINATE ALL' ' WORK WITH THE FURNITURE VENDOR C. ALL EXISTING FURNITURE THAT IS NOT BEING RE -USED IS TO BE MARKED FOR THE FURNITURE VENDOR FOR REMOVAL OR AS NOTED BY SPM ` PROJECT MANAGER THE GC WILL COORDINATE WITH THE EQUIPMENT VENDOR FOR PICK-UP OF EQUIPMENT AS NOTED IN THE CONSTRUCTION SCHEDULE. D. 5 p® AND SPM TO COORDINATE ALL WORK OF.(AND WITH) TECH OPS AS REQUIRED. - ' TECH OPS IS RESPONSIBLE FOR THE REMOVAL OF ALL DECOMMISSIONED BANK EQUIPMENT (EXCLUDING FURNITURE) AS REQUIRED. TECH OPS WILL COORDINATE WITH ALL TRADES AND VENDORS AS REQUIRED. REFER TO DESIGN STANDARDS DRAWINGS DETAILS 14-151R 2.3 (LATEST REVISION). F. m � D•O6 REDEPLOYMENT. GC TO COORDINATE WITH SPM AND VENDORS AS - G. POWER AND DATA IS TO BE TERMINATED AND OR RELOCATED FROM ALL FURNITURE AND EQUIPMENT REMOVAL / RELOCATIONS. ALL WORK SHALL MEET THE REQUIREMENTS OF THE GOVERNING BUILDING OR ELECTRICAL CODE. H. THE GC ALONG WITH THE SPM, WILL COORDINATE WITH APPROPRIATE VENDOR FOR THE REMOVAL OF THE EXISTING EMERCH MONITORS. THE GC WILL COORDINATE WITH ALL ASSIGNED VENDORS. - J. ALL NOTES AND EXISTING CONDITIONS INDICATED ON PROPOSED PLAN SHALL BE FIELD VALIDATED BY SCOPING TEAM. K ALL TCD'S TO BE REMOVED UNLESS NOTED OTHERWISE. GCI SPM TO VERIFY WITH BCM EXISTING TCD'S TO REMAIN. L. REMOVE EXISTING DIGITAL TELLER LINE MONITOR AND/ OR TELLER WINDOW IDENTIFICATION (NUMBERING) AT ALL TELLER POSITIONS. . DEMOLITION NOTES D-01 REMOVE THE EXISTING CSC. FINISHES ARE TO MATCH EXISTING SURROUNDING CONDITIONS. EXISTING FLOOR BOX TO REMAIN. PROVIDE COVER PLATE APPROVED FOR WALKING TRAFFIC. NEW COVER TO ALIGN WITH ADJACENT FINISHES. REMOVE EXISTING PENDANT LIGHT FOR REINSTALLATION AS NEEDED. TERMINATIONS ARE TO BE DONE PER CURRENT LOCAL CODE REQUIREMENTS.SEE CONSTRUCTION NOTES AND SCHEDULES FOR REMAINDER OF REQUIRED WORK. D-02 REMOVE EXISTING WHITE PENDANT LIGHT FIXTURES AT TELLER POSITIONS. SALVAGE FOR POSSIBLE RE -USE. MI REMOVE THE EXISTING WALL COVERING AND SIGNAGE FROM THE TELLER LINE SOFFIT / MOCK SOFFIT. PATCH AND PREP SOFFIT FOR NEW FINISHES PER THE FINISH SCHEDULE. - - D-04 KEEP EXISTING PIN PADS IDENTIFIED FOR RE -INSTALLATION. DECOMMISSIONED PIN PADS ARE TO BE REMOVED ALONG WITH POWER AND DATA CONNECTIONS. RETURN EQUIPMENT TO THE SPM OR DESIGNATED AGENT. D-05 REMOVE EXISTING FDIC AND MARKETING SIGNAGE AT DECOMMISSIONED TELLER POSITIONS. D-06 EXISTING DEAL DRAWER TO BE DECOMMISSIONED. SPM ALONG WITH BRANCH MANAGER ARE TO INSPECT DEAL DRAWER TO ASSURE THE UNIT HAS BEEN DECOMMISSIONED CORRECTLY. 0-11 0 . (.T FM I> CSC D.04 D•O2 i----- d D•01 Co T oN �- 0 D•03-- ,Q 3 ' 'COFFEE 00, CART ID '---- - .. - ATM ATM AHD MIDm M 0 Z 100% � D CESK - / /CHECK, \ / D'O•� O _ 0 Y 4' 8' 76' DEMOLITION PLAN Confidential. JPMorgan Chase Bank, N.A. Proprietary Information. DEMOLITION GENERAL NOTES A ALL DEMOLITION WORK IS SHOWN IN RED. ALL RELOCATED/REUSED WORK IN BLUE. - - B. FURNITURE VENDOR IS TO BE RESPONSIBLE FOR ALL FURNITURE THAT IS REMOVED AND / OR RELOCATED. GENERAL CONTRACTOR (GC) AND . [SUPERVISOR (PROJECT MANAGEMENT)) (SPM) ARE TO COORDINATE ALL' ' WORK WITH THE FURNITURE VENDOR C. ALL EXISTING FURNITURE THAT IS NOT BEING RE -USED IS TO BE MARKED FOR THE FURNITURE VENDOR FOR REMOVAL OR AS NOTED BY SPM PROJECT MANAGER THE GC WILL COORDINATE WITH THE EQUIPMENT VENDOR FOR PICK-UP OF EQUIPMENT AS NOTED IN THE CONSTRUCTION SCHEDULE. D. TECHNICAL OPERATIONS (TECH OPS) IS RESPONSIBLE FOR THE REMOVAL OF ALL DECOMMISSIONED BANK EQUIPMENT REQUIRING A RIGGER GC AND SPM TO COORDINATE ALL WORK OF.(AND WITH) TECH OPS AS REQUIRED. - E. TECH OPS IS RESPONSIBLE FOR THE REMOVAL OF ALL DECOMMISSIONED BANK EQUIPMENT (EXCLUDING FURNITURE) AS REQUIRED. TECH OPS WILL COORDINATE WITH ALL TRADES AND VENDORS AS REQUIRED. REFER TO DESIGN STANDARDS DRAWINGS DETAILS 14-151R 2.3 (LATEST REVISION). F. GC IS RESPONSIBLE FOR THE REMOVAL OF AND SAFE STORAGE OF EXISTING MERCHANDISING AND SIGNAGE FOR REUSE OR REDEPLOYMENT. GC TO COORDINATE WITH SPM AND VENDORS AS REQUIRED. G. POWER AND DATA IS TO BE TERMINATED AND OR RELOCATED FROM ALL FURNITURE AND EQUIPMENT REMOVAL / RELOCATIONS. ALL WORK SHALL MEET THE REQUIREMENTS OF THE GOVERNING BUILDING OR ELECTRICAL CODE. H. THE GC ALONG WITH THE SPM, WILL COORDINATE WITH APPROPRIATE VENDOR FOR THE REMOVAL OF THE EXISTING EMERCH MONITORS. THE GC WILL COORDINATE WITH ALL ASSIGNED VENDORS. - J. ALL NOTES AND EXISTING CONDITIONS INDICATED ON PROPOSED PLAN SHALL BE FIELD VALIDATED BY SCOPING TEAM. K ALL TCD'S TO BE REMOVED UNLESS NOTED OTHERWISE. GCI SPM TO VERIFY WITH BCM EXISTING TCD'S TO REMAIN. L. REMOVE EXISTING DIGITAL TELLER LINE MONITOR AND/ OR TELLER WINDOW IDENTIFICATION (NUMBERING) AT ALL TELLER POSITIONS. . DEMOLITION NOTES D-01 REMOVE THE EXISTING CSC. FINISHES ARE TO MATCH EXISTING SURROUNDING CONDITIONS. EXISTING FLOOR BOX TO REMAIN. PROVIDE COVER PLATE APPROVED FOR WALKING TRAFFIC. NEW COVER TO ALIGN WITH ADJACENT FINISHES. REMOVE EXISTING PENDANT LIGHT FOR REINSTALLATION AS NEEDED. TERMINATIONS ARE TO BE DONE PER CURRENT LOCAL CODE REQUIREMENTS.SEE CONSTRUCTION NOTES AND SCHEDULES FOR REMAINDER OF REQUIRED WORK. D-02 REMOVE EXISTING WHITE PENDANT LIGHT FIXTURES AT TELLER POSITIONS. SALVAGE FOR POSSIBLE RE -USE. MI REMOVE THE EXISTING WALL COVERING AND SIGNAGE FROM THE TELLER LINE SOFFIT / MOCK SOFFIT. PATCH AND PREP SOFFIT FOR NEW FINISHES PER THE FINISH SCHEDULE. - - D-04 KEEP EXISTING PIN PADS IDENTIFIED FOR RE -INSTALLATION. DECOMMISSIONED PIN PADS ARE TO BE REMOVED ALONG WITH POWER AND DATA CONNECTIONS. RETURN EQUIPMENT TO THE SPM OR DESIGNATED AGENT. D-05 REMOVE EXISTING FDIC AND MARKETING SIGNAGE AT DECOMMISSIONED TELLER POSITIONS. D-06 EXISTING DEAL DRAWER TO BE DECOMMISSIONED. SPM ALONG WITH BRANCH MANAGER ARE TO INSPECT DEAL DRAWER TO ASSURE THE UNIT HAS BEEN DECOMMISSIONED CORRECTLY. ITY OF LA QU BUILDING & SAFETY DEIPA LEGEND: /�.-.p,� "'•� FLOOR MATERIAL KEY NOTE EXTENTS � I P R O ` C ® ' i.C_•�.,i V C EXISTING TO BE REMOVED FOR p EXISTING FURNITURE REUSED /RELOCATED Fl CONSTRUCTION OKEYED NOTE - - I DATE SC/KC 2015-07-08--T� BY N•05 0OFFICE OFFI E OF ICE 11-11 Al 11-11 Il -II PROPOSED FLOOR PLANS Confidential. JPMorgan Chase Bank, N.A. Proprietary Information. GENERAL NOTES A. THE GENERAL CONTRACTOR (GC) WILL PROVIDE ON SITE SUPERVISION FOR ALL AFTER HOURS WORK AND WILL OVERSEE ALL VENDOR'S _ PROVIDING SERVICES FOR THIS PROJECT. B. THE GC SHALL REFER TO THE LEGEND ON EACH SHEET FOR NEW INTENDED WORK BY COLOR, INCLUDING NEW EQUIPMENT, SYSTEMS - FURNITURE, OFFICE CONSTRUCTION, INSTALLATIONS, RELOCATED/ REUSED WORK, AND DESIGNATED PROGRAM WORK. DEMOLITION WORK IS PN -03 NOT SHOWN ON THIS PLAN. THE GC IS TO COMPARE THE EXISTING AND PROPOSED PLANS TO DETERMINE GENERAL DIFFERENCES IN THE PLAN AND EXTENTS OF NEW WORK. ACTUAL DEMOLITION REQUIREMENTS SHALL PN -04 BE FIELD VERIFIED AND COORDINATED WITH SUPERINTENDENT.. - C. ALL NOTES AND EXISTING CONDITIONS INDICATED ON PLAN SHALL BE FIELD VALIDATED BY SCOPING TEAM D. GC IS TO START ALL DIMENSIONS FROM THE SHOWN WORK POINTS. BUILDING DIMENSIONS MAY VARY FROM THE PLAN. . E. [SUPERVISOR (PROJECT MANAGEMENT)] (SPM) WILL COORDINATE WITH THE MERCHANDISING MANAGER FOR ALL SIGNAGE NEW AND EXISTING THAT IS TO BE REMOVED AND INSTALLED. GC WILL COORDINATE WITH THE MERCHANDISING VENDOR AS NEEDED FOR SCHEDULING., F. ALL EXISTING BUILDING SYSTEMS (LIGHTING, POWER DATA, SECURITY, PN -07 FIRE SPRINKLERS, HVAC, ETC.) SHALL REMAIN AS IS. FIELD VERIFY EXACT EXTENTS AT AREAS AFFECTED BY DEMOLITION /CONSTRUCTION. NOTIFY SPM IMMEDIATELY IF CONFLICTS ARISE. G. PRIOR TO CORING, TRENCHING, OR PLACING EQUIPMENT ON SLAB GC. WILL X-RAY SLAB REQUIREMENTS FOR NEW WORK, GC WILL COORDINATE PN -06 ALL SLAB WORK WITH SPM H. GC IS RESPONSIBLE FOR OBTAINING A STRUCTURAL ENGINEER'S _ VERIFICATION THAT THE EXISTING FLOOR LOAD CAPACITIES CAN ACCOMMODATE ALL NEW EQUIPMENT. IF EXISTING FLOOR LOAD CAPACITIES CANNOT ACCOMMODATE NEW EQUIPMENT, THEN GENERAL CONTRACTOR SHALL PROVIDE ALL NECESSARY STRUCTURAL FLOORING ALTERATIONS REQUIRED TO MEET THESE REQUIREMENTS. J. ALL RELOCATED DESKS ARE TO RECEIVE POWER AND DATA. SEE DESIGN STANDARD DRAWINGS (DSD) FOR LOCATIONS. * ALL FURNITURE AND FURNITURE PANELS TO MATCH EXISTING, UNLESS NOTED OTHERWISE AND ARE PROVIDED BY THE FURNITURE VENDOR FURNITURE VENDOR TO SURVEY EXISTING FURNITURE PANELS AND DETERMINE IF ADDITIONAL NEW FURNITURE PANELS ARE NEEDED TO ENABLE THE FINAL LAYOUT /CONFIGURATION. FURNITURE VENDOR IS RESPONSIBLE FOR STRUCTURAL SUPPORT AND CONNECTION OF FURNITURE PANELS. L NEW FULL HEIGHT WALLS ARE SHOWN WITH SOLID FILL EXISTING WALLS TO REMAIN ARE SHOWN WITHOUT FILL NEW PARTIAL HEIGHT WALLS ARE NOTED ON PLAN. M. PLEASE SEE THE PAINTING SCHEDULE ON INNOVATION RETROFIT FINISH REQUIREMENTS SHEET IR 2.2 (LATEST REVISION). SCOPING SPM WILL VERIFY THE EXISTING WALL COLOR AND PROVIDE NOTIFICATION TO ADRE DEPARTMENT. N. THE GC IS RESPONSIBLE FOR ALL FLOOR PROTECTION DURING CONSTRUCTION AND THE DELIVERY AND INSTALLATION OF THE CR'S I NEW ATM S. P. EXISTING FLOORING TO REMAIN UNLESS NOTED OTHERWISE OR AFFECTED BY DEMOLITIONICONSTRUCTION. PATCH, REPAIR AND INFILL AS REQUIRED. Q. WHERE TRENCHING OR CORE DRILLING IS REQUIRED SUB FLOORING AND OR SUBSTRATE SHALL BE RETURNED TO A LEVEL CONDITION. WHERE (OAR'S) ARE PROVIDED OVER EXISTING FINISHES, PATCHING DUE TO CONSTRUCTION ACTIVITY WILL MATCH ADJACENT EXISTING OR NEW FINISHES. R EXISTING CEILINGS TO REMAIN UNLESS NOTED OTHERWISE OR AFFECTED BY DEMOLITIONICONSTRUCTION. PATCH, REPAIR AND INFILL AS REQUIRED, COORDINATE WITH SPM S. PROVIDE PRE -FINISHED FLUSH CAP AT ABANDONED PENDANT LIGHT FIXTURE. COLOR TO MATCH ADJACENT CEILING COLOR INSTALL PENDANT LIGHT FIXTURES PER TO DSD. T. SECURITY PROJECT MANAGER WILL PROVIDE A SECURITY PLAN FOR THE PROJECT UNDER A SEPARATE COVER THE GC WILL COORDINATE ALL REQUIRED WORK BY THE ASSIGNED VENDOR U. SIGNAGE VENDOR WILL REINSTALL EXISTING BUSINESS BANKING SIGNAGE TO BE CENTERED ON MERCHANT TELLER POSITION (MST). PLAN NOTES. PN -01 RECONFIGURE LOBBY AREA FOR NEW eATMS AS SHOWN ON PLAN. - LOCATE NEW / EXISTING QUEUING STANCHIONS AS SHOWN ON THE PROPOSED FLOOR PLAN. PN -02 INSTALL NEW TELLER STACKER INFILL PANEL AS SHOWN ON PLAN AT NON -OPERATIONAL TELLER WINDOWS AND ACCESS TELLER (AT) - POSITIONS. PROVIDE AND INSTALL AS REQUIRED PER DSD DETAILS 14.15/ IR 2.5 AND RDC 15-001 (LATEST REVISION). PN -03 PROVIDE NEW OR REUSE EXISTING BLUE PENDANT LIGHT FIXTURES CENTERED AT ALL ACTIVE TELLER STATIONS EXCEPT AST PER DSD 2 & 5/ IR 1.2 (LATEST REVISION). - PN -04 RE -INSTALL TELLER PIN PADS AT ALL ACTIVE TELLER STATIONS. PROVIDE POWER AND DATA PER DSD.10.11/ IR 2.3 AND RDC 13-004 (LATEST REVISION). ' PN -05 INSTALL NEW TABLET CHARGER (TC) ON EXISTING COUNTER CONNECT TO EXISTING POWER PN -06 INSTALL NEW eATM 3.0 LOCATIONS AS SHOWN ON THE PLAN, RE -USE EXISTING OR PROVIDE NEW POWER AND DATA FROM TELLER SIDE OF ADJACENT TELLER LINE OR WALL CONSTRUCTION. INSTALL POWER DATA, SECURITY, AND CLOSURE PANEL PER DSD DETAILS 4.7 ON SHEET IR 2.5 (LATEST REVISION). PN -07 FUTURE eATM AS SHOWN ON THE PLAN, PROVIDE AND INSTALL J -BOX TO ADJACENT TELLER LINE OR WALL CONSTRUCTION. LOCATE IN - ACCORDANCE WITH DESIGN GUIDANCE FOR eATM J3.0. INSTALL POWER, - DATA, AND CLOSURE PANEL PER DSD DETAILS ON SHEET IR 2.5 (LATEST REVISION). PN -06 PROVIDE HOLD -OPEN FUNCTIONALITY AT EXISTING VESTIBULE DOOR(S). GC SHALL VERIFY THAT EXISTING DOOR(S) HAVE HOLD -OPEN FUNCTIONALITY OR PROVIDE NEW KICK DOWN HOLDER AS REQUIRED BY DSD HARDWARE SET 2A. DOOR HARDWARE SCHEDULE/ IR 2.2 (LATEST REVISION). - - LEGEND: EXISTING PARTITION TO REMAIN NEW PARTITION EXISTING FURNITURE REUSED /RELOCATED NET NEW NEW SIGNAGE / MARKETING FUTURE PATH OF TRAVEL eATM SIGNAGE PANEL NEW BORDER TILE NEW MILLWORK # KEYED NOTE SC/KC 2015-07-08 0 2' 4' B' 16' FINISH PLAN 77 Confidential. JPMorgan Chase Bank, N.A. Proprietary Information. CHASE �� RETAIL DISTRIBUTION NETWORK UNLESS NOTED OTHERWISE. ' B. ALL NOTES INDICATED ON THE PROPOSED PLAN SHALL BE FIELD FINISH PLAN GENERAL NOTES A. ALL NEW FINISHES AND MATERIALS TO MATCH EXISTING FINISHES, UNLESS NOTED OTHERWISE. ' B. ALL NOTES INDICATED ON THE PROPOSED PLAN SHALL BE FIELD VALIDATED BY SCOPING TEAM C. GENERAL CONTRACTOR (GC) IS TO START ALL DIMENSIONS FROM THE SHOWN WORK POINTS. BUILDING DIMENSIONS MAY VARY FROM THE PLAN. D. EXISTING CEILINGS TO REMAIN UNLESS NOTED OTHERWISE OR AFFECTED BY DEMOLITION /CONSTRUCTION. PATCH, REPAIR, AND INFILL / REPLACE TO MATCH EXISTING OR AS NOTED. E. EXISTING FLOORING TO REMAIN UNLESS NOTED OTHERWISE OR AFFECTED BY DEMOLITION /CONSTRUCTION. PATCH, REPAIR, AND INFILL / REPLACE TO MATCH EXISTING AS NOTED AND SHOWN. WHERE TRENCHING OR CORE DRILLING IS REQUIRED, SUB FLOOR AND / OR SUBSTRATE SHALL BE RETURNED TO A LEVEL CONDITION. F. GC WILLCOORDINATE WITH THE MERCHANDISING VENDOR FOR THE REINSTALLATION OF EXISTING AND NEW MERCHANDISING AND INTERIOR SIGNAGE ELEMENTS. G. REPLACE EXISTING BASE WITH NEW TO MATCH EXISTING IN AREAS OF FLOORING OR WALL COVERING REMOVAL AND REINSTALLATION HAS OCCURRED. H. PROVIDE NEW TRANSITION STRIPS AS REQUIRED - MATCH EXISTING TYPES STYLES AND FINISHES. FINISH PLAN NOTES FIN -01 PAINT TELLER UNE BACK WALL IN ACCORDANCE WITH INTERIOR FINISH MATERIAL LEGEND DSD SHEET IR 2.1 AND INNOVATION RETROFIT FINISH REQUIREMENTS LEGEND SHEET IR 2.2 (LATEST REVISION). FIN -02 REFINISH THE EXISTING KMDI MOCK SOFFIT w/ (1) FULL COAT OF KILZ WHITE PRIMER (PRIMER WASHES ARE NOT ACCEPTABLE) AND (3) COATS MAIN BRANCH COLOR PAINT FINISH IS TO BE ROLLED. LEGEND: NEW CARPET NEW TILE NEW AREA RUG OVER FLOOR FINISH WALL FINISH EXTENT NEW SIGNAGE / MARKETING NEW BORDER TILE NEW MILLWORK # KEYEDNOTE SC/KC 2015-07-08 CHASE e� RETAIL DISTRIBUTION NETWORK - 0 2' 4' 8' 16' EQUIPMENT PLAN Confidential. JPMorgan Chase Bank, N.A. Proprietary Information. EQUIPMENT GENERAL NOTES A.. ALL NEW POWER /DATA /SECURITY WORK SHOWN IN BLUE.. . B. ALL NOTES INDICATED ON PLAN SHALL BE FIELD VALIDATED BY SCOPING . TEAM. C. GENERAL CONTRACTOR IS TO START ALL DIMENSIONS FROM THE SHOWN WORK POINTS. BUILDING DIMENSIONS MAY VARY FROM THE PLAN. D.'. GC / ELECTRICAL CONTRACTOR TO CAP (FLUSH WITH FLOORING) EXISTING OR ABANDONED FLOOR BOXES. NEW TOP TO BE FOOT TRAFFIC RATED. E. FOR NEW POWER / DATA /SECURITY FLOOR LOCATIONS GENERAL CONTRACTOR / ELECTRICAL CONTRACTOR TO USE MOST DIRECT ROUTE WITH THE LEAST FLOOR AND CONSTRUCTION IMPACT. F. GC / ELECTRICAL CONTRACTOR TO DETERMINE THE SIMPLEST - INSTALLATION (EITHER WALL OR FLOOR MOUNTED) FOR WORKSTATION POWER/DATA INSTALLATION. G. FOR EQUIPMENT REFER TO. BANK EQUIPMENT SCHEDULE DSD SHEET IR 2.2 (LATEST REVISION)... .. EQUIPMENT PLAN NOTES EN -01 RE -INSTALL TELLER PIN PADS AT ALL ACTIVE TELLER STATIONS. PROVIDE POWER AND DATA PER DSD.10.11/ IR 2.3 AND RDC 13004 (LATEST . REVISION). - EN -02 PROVIDE AND INSTALL NEW (MATCH EXISTING WHEN PRESENT) OR RELOCATED DUAL BAND QUEUE ROPES AND STANCHIONS IN - ACCORDANCE WITH DSD SCHEDULED EQUIPMENT. . EN -03 PROVIDE AND INSTALL POWER/ DATA/ SECURITY FOR NEW eATM PER DSD DETAILS 47 ON SHEET IR 2.5 (LATEST REVISION). - EN -04 PROVIDE AND INSTALL POWER/ DATA/ SECURITY J -BOX FOR FUTURE eATM PER DSD DETAILS 47 ON SHEET IR 2.5 (LATEST REVISION). EN -05 INSTALL NEW TABLET CHARGER (TC) ON EXISTING COUNTER. CONNECT TO EXISTING POWER. CITY OF LA QTM oN TA BUILDING & SAFETY APPROVED LEGEND: 1 FOR CONSTRUCTION BE BANK EQUIPMENT BY CENTER POINT OF REQUIRED FLOOR DEVIC� DATE ® KEYED NOTE SC/KC 2015-07-08 PAGE 5.0