Loading...
0307-393 (CSCS)LICENSED CONTRACTOR DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professionals Code, and my License is in full force and effect. License # Lic. Class Exp. Date ,626242 ( 33 CP Coq Signature of OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from tyle Contractor's License Law for the following reason: Pk ( ) I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec. 7044, Business & Professionals Code). ( ) I, as owner -of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business & Professionals'' Code). ( ) I am exempt under Section B&P.C. for this reason Date Signature of Owner WORKER'S COMPENSATION DECLARATION I hereby affirm under. penalty of perjury one of the following declarations: ( ) I have and will maintain a certificate of consent to self-insure.for workers'. compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. ( ) I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier & policy no. are: Carrier gTATy yVT LN ' Policy No. 15013616.01 (This section need not be completed if the permit valuation is for $100.00 or less). ( ) I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that if I should become subject to the workers' compensation provisions of Section 3700 of the Labor Code, I shall forthwith' comply with those provisions. ,,,.,Date: m Applicant -��' �'Z Warning: Failure to secure Workers' Compensation overage is unlawful and shall "subject an employer to criminal penalties and III fines up to $100,000, in addition to the cost of•compekation, damages as p ovided for in Section 3706 of. the Labor Code, inte-res�and attorney's fees. IMPORTANT Application is hereby made to the D rector of Building and Safety fob a permits subject' t6 -'the, conditions and rAirictions set forth on his application-' �, 1. Each person upon whose behalf.':this application is made & each person at whose request and for whose benefit'work is performed under or pursuant to any permit issued as a result of this applicaton agrees to, & shall, indemnify & hold harmless.the City of La Quinta, its officers, agents and employees. 2. Any permit issued" s a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I c,,Kif that I have read this application and state that the above information is correct: I agree to comply with all City, and State laws relating to the building construction, and hereby authorize representatives of this City to enter upon the above mentioned property for inspection purposes. > rrc atT�•-fsCSignature. (OwneAent) N A " BUILDING PERMIT PERMIT#W07-391 - DATE / / / VALUATION LOT f1 TRACT 1 tfiA�j G C .i.rJ i 4f t� c�`4•.R, Y,'94:�A .r U j' P;s JOB SITEi py ADDRESS `'K nL1' i 9. � APN 64'3 " 7 OWNER CONTRACTOR / DESIGNER / EN (NEER 71 -OS4 TA1;12.I=X,..A1,%✓' 78.600 RfYt31"MAY I I I RtiAi'010 lt(IRAGE CA 92270 I.A, Qi$1 ;r .k CA 92253 (BOJ i l w3:345 i:At /? 7108 S . USE OF PERMIT CC3MNERC,IAL COMMERCIAL SHELL, IMI OCCUPANCY, TYPii`iP'AI SPIZIN SLED (10,Sn►3 SZ) 2001 CDC 00R,4',t3IF':4` IO '�. 63,0'J SFS ST+1II�Ki.I�It. it�,3ti13.�0 Sl< AIR: -- COMMERCIAL OF CONTRA�`P It,It4OUNT SX�,Pi1°7.60 L.- ='MAIIIND C110s"'l' 0111 COI+I•S'l'A UC1'.1off 4$,X,461_50 CONSTRUCTION TION W 101.000.418 000 $1lo1,S PE.6A4 CHECK. Iris 101-.000449-3. A 91,519X"..: YET DEPOSIT 101-000439-318 •31,600,00 McCI IANIC.d•AL, PER � 101,000-421-000 $245.50 ELEC IUCALFLIi 001.60 I'I�f. MBI'NO E'f:P 101-000-419-000 I:ti.50 ; STROkdtY lt+l•ClT1014 RE'. ':OMIM 100-000-24 1? -000 $86,41 GRA.PINO FEE 10i-000-423-000 DEVELOPER IMPACT FEF ART IN PUBLIC �'oe.CI:S < CC7.IhF 270-0004,45 -000 $40".51 3tTB-`r%'YrAT COI-IMUMTON AND PI -00 CHECK o`= 13S.0 PRE-PAIDIMS 41 600.00 i -_�-- — Y .PEWI ft!,Q,T FR95 DUE NOW 2004 :A„�IS9s APR 0 5 1 J QU,@% CA ITY RECEIP DATEBY t DAT I INSP r✓" V - w on INSPECTION RECORD OPERATION DATE INSPECTOR BUILDING APPROVALS Set Backs Forms & Footings Slab Grade Steel Roof Deck O.K. to Wrap Q Framing Insulation Fireplace P.L. Fireplace T.O. Party Wall Insulation Party Wall Firewall Exterior Lath Drvwaii - Int. Lath 471 OPERATION DATE INSPECTOR MECHANICAL APPROVALS lerground Ducts :ts _ um Air nbustion Air aust Fans .U. npressor its Is is & Controls , s idensate Lines Final a '' POOL_ S - SPAS BLOCKWA!LL APPROVAL6' st6el Set Backs 1 Electric Bond Footings Main Drain,*". Bond Beam 49pwa4, 11W Approval to Cover 9'Q4_M A. -;j T6- - • O Equipment, Location . Underground Electric • Underground Pibg.Test• Final Gas Piping PLUMBING APPROVALS Gas Test Electric Final ., . Waste Lines C4AI Heater Final ` Water Piping Plumbing Final Plumbing Top Out Equipment Enclosure Shower Pans O,K. for Finish Plaster Sewer Lateral S Pool Cover : Sewer Connection Encapsulation, Gas Piping Gas Test Appliances Final' ` COMMENTS: Final Utility Notice (Gas) p ELECTRICAL APPROVA 5 Temp. Power Pole Underground Conduit Rough Wiring Low Voltage Wiring Fbdures Main Service Sub Panels Exterior Receptacles71 G.F.I. Smoke Detectors Tema. Use of Power [ Final Utility Notice CERTIFICATE OF COMPLIANCE Desert Sands Unified School District �4-coo 47950 Dune Palms Road Q BERMUDA DUNES Date 2/9/04 La Quinta, CA 92253 rn RANCHO MIRAGE d No. 25490 (760) 771-8515 NJ INDIMDESERT WELLS PALM DESERT y� L NDIO A I Q0 1�3 Owner One Eleven La Quinta APN # 643-080-045 Address 71-084 Tamarisk Lane Jurisdiction La Quinta City Rancho Zip Permit # 0307-393 Tract # Pm25865 Study Area Type Commercial No. of Units 1 Lot # No. Street S.F. Lot # No. Street S.F. Unit 1 1 P9 78982 Highway 111 10580 Unit 6 Unit 2 Unit 7 Unit 3 Unit 8 Unit 4 Unit 9 Unit 5 Unit 10 Comments At the present time, the Desert Sands Unified School District does not collect fees on garages/carports, covered patiostwalkways, residential additions under 500 square feet, detached accessory structures (spaces that do not contain facilities for living, sleeping, cooking, eating or sanitation) or replacement mobile homes. It has been determined that the above-named owner is exempt from paying school fees at this time due to the following reason: EXEMPTION NOT APPLICABLE This certifies that school facility fees imposed pursuant to Education Code Section 17620 and Government Code 65995 Et Seq. in the amount of $0.34X 10,580 S.F. or $3,597.20 have.been paid for the property listed above and that building permits and/or Certificates of Occupancy for this square footage in this proposed project may now be issued. Fees Paid By OCMells Fargo - Dave Smoley Check No. 0737704084 Name on the check Telephone Funding Commercial By Dr. Doris Wilson Superintendent Fee collected /exempted b hero MC ilvrey,, Payment Recd $O.00 Q( „ $3,597.20 Over/Under Signature NOTICE: Pursuant to Government Code Sech 66020(d)(1), this wi I serve to notify you that the 90 -day approval period in which you may protest the fees or other payment identified above will begin to run from the date on which the building or installation permit for this project is issued, or from the date on which those amounts are paid to the District(s) or to another public entity authorized to collect them on the District('s) behalf, whichever is earlier. NOTICE: This Document NOT VALID if Duplicated Embossed Original - Building Department/Applicant Copy - ApplicanVReceipt Copy -Accounting CALIFOANIq Y QVlt RP Tfalk RIVERSIDE COUNTY FIRE DEPARTMENT a�dE1PE PROIECTlpN DIn cooperation with the F California Department of Forestry and Fire Protection • Eag10E g'gU, 210 West San Jacinto Avenue - Perris, California 92570 - (909) 940-6900 - Fax (909) 940-6910 Tom Tisdale Fire Chief Proudly serving the Unincorporated Areas of Riverside County and the Cities of Banning . Beaumont Calimesa 4. Canyon Lake , Coachella Desert Hot Springs 4. Indian Wells Indio .. Lake Elsinore .;. La Quinta .y Moreno Valley 4. Palm Desert Penis Rancho Mirage 4. San Jacinto Temecula Board of Supervisors Bob Buster, District 1 John Tavaglione, District 2 Jim Venable, District 3 Roy Wilson, District 4 Marion Ashley, District 5 March 3, 2004 To: City of La Quinta . Building Department Re: ' -Release for Permit _ __ LAQ-03-TI-050178-982 Hwy III, Retail shops' The Riverside County Fire Department hereby releases the above referenced project for issuance of a permit for construction, at the discretion of the Building Department. Res fully, Dale A. Evenson Fire Safety Specialist H%QF=ENERALWORAASMUdg Permh Release - LOA= EMERGENCY SERVICES DMSION - PLANNING SECTION - INDIO OFFICE 82-6675 Highway 111, 2ne Fl., Indio, CA 92201 - (760) 863-8886 - Fax (760) 863-7072 • TAlf °F �WQ�t�tw Building & Safety Department Public Works Release to Issue Building Permit To: John Freeland, Senior Engineer Date to PWD: 3-25-2004 From:'Greg Butler, Building & Safety Manager Permit #:0307-393 A release from Public Works Department is required prior to building permit issuance for the following project: Description: 10580 SF SHELL BLDG Address or general location: 78-982 Hwy 111(NW Corner A4ams�i i l� L.O+ 2 oP LLA 95-19-7 sb? Q0031770 APN and/or legal description: Applicant contact and telephone number: DAVE SMOLEY 771-3345 Please do not return this form to Building & Safety Department until released for building permit issuance. For issues delaying or preventing release, please contact applicant directly at the number above. Note: Action required (reply to Building Department or contact Applicant) within five (5) working days from date received by Public Works Department. To: Greg Butler, Building & Safety Manager From: John Freeland, Senior Engineer The Public Works Department has reviewed the above project and finds that: ❑ ... issuance of this Building Permit does not require Public Works Department approval. issuance of this Building Permit is approved by the Public Works Department. John. Freeland, Senior Engi GoodyearMgreen — 4/18/03 0I Date 9 JHA ENGINEERING, INCORPORATED C O N S U LTJ N G C I V 11: 1 N G I N E G R S • S U R V E Y I N G April 1, 2004 City of La Quinta 78495 Calle Tampico La Quinta, Ca 92253 ATTN: Building & Safety Department SDP No.: 2003-770 Re: Retail Buildings — Consolidated Contracting, Inc. — (Desert Cities Development) Address: 78982 Highway 111, La Quinta, Legal: Lot 1 — Lot Line Adjustment No. 95-197 Gentlemen, This letter shall serve as a certification stating that the grading of said lot has been done in accordance with the approved grading plan. Our office conducted a field inspection.of this site and found that the pad elevation was constructed to an elevation of 76.4 and the approved elevation for the pad was 76.4. This falls within the tolerance of standard grading practice. Sincerely, OQROFEft (fJohn H. Hacker R.C.E. 14614 wA90. 14614m Exp 3/31/05 UP. 3-31-05 N �9TF CIVIC. OQ�\ JHH /wa p OF C A 1 Yc/file 032147c.001 Pad Cert 41921 BEACON HILL - SUITE A - PALM DESERT, CA. 92211 (760) 779-0657 FAX (760) 779-5143 To: Greg Butler, Building & Safety Manager To CDD: 10/17/2003 From: Oscar Orci, Planning Manager Due date: 10/24/2003 Status:2n-d review Building Plans Approval (This is an approval to issue a Building Permit) a The Community Development Department has reviewed the Building Plans for the following project: Description: 10,580 Commercial Shell Address or general location: 78-982 hwy 111 Applicant Contact: Desert Cities Dev. (760) 771-3345 The Community Development Department finds that: ❑ ...these Building Plans do not require Community Development Department approval. these Building Plans are approved by the Community Development Department. 0 ...these Building Plans require corrections. Please forward a copy of the attached corrections to the applicant. When the corrections are made please return them to the Community Development Department for review., -r .r ate a -g w as •�'�` e.1 yv. ' :MR Oscar Orci, Planning Manager W I ►! � v�Ux•ty Olhl� V-'e'JVU W I Ti4f 4 �w4" P.O. BOX 1504 BUILDING & SAFETY DEPARTMENT 78-495 CALLE TAMPICO (760).777-7012 LA QUINTA, CALIFORNIA 92253 FAX (760) 777-7011 To: Greg Butler, Building & Safety Manager To CDD: 4-23-2004 From: Oscar Orci, Planning Manager Due date: 5-6-2004 Status: I" Review .Building Plans Approval (This is an approval to issue a Building Permit) The Community Development Department has reviewed the Building Plans for the following project: Description: One Eleven La Quinta g Address or general location: 78-982 Highway 111 Applicant Contact: Dave Smoley 760-771-3345 The Community Development Department finds that: ❑ ...these Building Plans do not requite Community Development Department approval. 'NJ ...these Building Plans are approved by the Community Development Department. ❑ ...these Building Plans require corrections. Please forward a copy of the attached corrections to the applicant. When the corrections are made please return them to the Community Development Department for review. Oscar Orci, Planning Manager Date R F STRUCTURAL CONSULTANTS, INC. 75-153 MERLE DRIVE, STE. B, PALM DESERT, CA 92211 PHONE (760) 836-1000 FAX (760) 836-0856 E- MAIL R. FRANGIE@VERIZON.NET OCTOBER 4, 2004 CONSOLIDATE CONTRACTING INC. 4' 46-753 ADAMS STREET LA QUINTA, CA. 92253 Attn.: MR. PHIL MANCINI Re.: THE RETAIL BUILDING �78=982::HIGHWAY�T:Iaa LA QUINTA,, CA, 92253 FOLLOW-UP TO WALK THROUGH JOB NO.: 4110 DEAR PHIL THIS LETTER ADVISES THAT WE HAVE OBSERVED THE STRUCTURAL REQUIREMENTS THAT ARE VISIBLE DURING CONSTRUCTION AT THE TIME OF OUR SITE VISIT. WE BELIEVE THAT THE AS -BUILT CONSTRUCTION AT THE TIME OF OUR VISIT IS IN GENERAL, CONFORMANCE WITH OUR. STRUCTURAL PLANS AND RELEVANT CORRESPONDENCE ISSUED BY OUR OFFICE. WE OBSERVED THE BUILDING IN ITS FRAMED CONDITION PRIOR TO INSTALLATION OF DRYWALL AND STUCCO. WE OBSERVED THE VISUAL AND ACCESSIBLE STRUCTURAL REQLm—EMENTS_ (FXCLUSILONS APRE ITEMS SUCH AS: FOOTING SIDE. AND<REINTORC v : T, TOR SLATE SPLs S, F�OOF ffrt�AT"G, AND A'� �' STR.� S :� Y O u Hi ROOF SlIE AT C=.). RESPETFlU.- ' S`BNUTT D Cl Q� p / c NICNOCAS F. �9 ASOU_ NO 50 EL EXP, ' � NICHOLAS ABOU FADEL, PEca`IFo NSP HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME DATE Retail Buildings 7/25/2003 SYSTEM NAME FLOOR AREA HP-1a,1b,1c,1d,1e,1f 6,080 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 6 Heating System Output per System 57,000 Total Output (Btuh) 342,000 Output (Btuh/sqft) 56.2 Cooling System Output per System 60,000 Total Output (Btuh) 360,000 Total Output (Tons) 30.0 Total Output (Btuh/sgft) 59.2 Total Output (sgft/Ton) 202.7 Air System CFM per System 2,000 Airflow (cfm) 12,000 Airflow (cfm/sgft) 1.97 Airflow (cfmrron) 400.0 Outside Air (%) 25.3 Outside Air (cfm/sgft) 0.50 Note: values above given at ARI conditions 26.0 of Outside Air 3040 cfm 69.6 of 112.0/77.90F �117 Outside Air 3040 cfm 74.9/67.7 of PSYCHROMETRICS 58.6 of 58.60F Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAK COIL HTG. PEAK CFM I Sensiblel Latent CFM I Sensible 359,994 39,223 249,004 CARRIER 50JX0605 251,587 98,478 224,924 Total Adjusted System Output 251,587 98,478 224,924 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK Jul 3 F Jan 12 am ream Temperatures at Time of Heating Peak) 76.2 of S I A' D t Supply Fan Heating Coil 12000 cfm k Return Air Ducts 4 84.3/70.4OF 84.3/70.4OF M 64.6/63.4OF Supply Fan Cooling Coil 12000 cfm 3.1 By EnergySoft User Number: 5354 Return Air Ducts Job Number: 03-181 upp y Ir uc s 75.8 of ROOMS 70.0 of Supply Air Ducts 65.4 / 63.7 of 71.8% R.H. ROOMS 74.0/67.4OF 18 of 18 Earth Systems 1Z7, Southwest June 18, 2003 Desert Cities Development 46-755 Adams Street La Quinta, California 92253 Attention: Mr. Dave Smoley Subject: Soil Engineering Report Update with Supplemental Recommendations Project: Proposed Retail Shops; Pad M3 One Eleven La Quinta Centre La Quinta, California 79-811 B Country Club Drive Bermuda Dunes, CA 92201 (760)345-1588 (800)924-7015 FAX (760) 345-7315 File No.: 09224-01 03-06-770 References: 1. Buena Engineers, Inc., Geotechnical Engineering Report, One Eleven La Quinta Center, La Quinta, California, File No.: B7 -2083-P1, Report No.: 90- 04-724, dated April 5, 1990. 2. Buena Engineers, Inc., Report of Testing and Observations During Grading, I 11, La Quinta Center, La Quinta, California, File No.: B7 -2083-P3, Report No.: 92-04-737, dated April 13, 1992. In accordance with your request, we have reviewed previously prepared documents associated with the previously completed rough grading and obtained one sample to be tested for pH, resistivity, soluble chloride, and soluble sulfate. The subject lot was originally mass graded as part of the existing shopping center development. Site Grading Based upon our review of the soil testing at the subject site, performed through April 14, 1998, it .is our opinion that the grading has been performed in general accordance with the original project plans and above referenced geotechnical engineering report. The subject building pad area was prepared and compacted as part of the overall mass grading. The existing pad grade of this lot was moisture conditioned, processed and compacted at the original grade. The intent of the grading was to densify the soil within the footprint of the proposed building to a depth of 3 to 4 feet below finish pad elevation. Based on our review of the available information it is our opinion that the subject pad was graded adequately for the proposed use. However, there is uncertainty that the limits of the previously completed grading completed on a previous building configuration with respect to the limits of the proposed building. The pad has remained dormant for over three years since the finish grading therefore some remedial effort is recommended prior to precise grading and building construction. The surface fill soils have dried out since the time of the original grading and compaction has likely decreased. Therefore, supplemental testing and probing of the soils around the perimeter of the proposed restaurant should be performed. If isolated soft areas are encountered supplemental compaction will be required to densify the soil JUN 2 3 2003 June 17, 2003 - 2 - File No.: 09225-01 03-06-770 to' a depth of at least 2 feet below the bottom of the footing bottoms as outlined below. Compaction of the bottom of the footing excavations should be verified by testing. If initial testing indicates that regarding of the site is necessary then the pad should be prepared by removing organic growth from the pad surface. The pad should then be over -excavated to a depth of 2 feet below the bottom of the deepest footing, scarified an additional 12 -inches, moisture conditioned and recompacted to a minimum of 90% relative compaction. Due to granular nature of the site soils it may be possible to moisture condition the upper 3 feet of soil and obtain compaction by using heavy equipment and compacting from the surface. If this method of compaction is used, test holes should be excavated to verify moisture penetration and the effects of the compactive effort. If it is found that either the desired moisture penetration or compaction cannot be achieved by this method, the soils will require over excavation and recompaction. If the current pad elevation is to be altered from its current elevation, fills should be compacted as recommended in the referenced soil engineering report. If the pad is to be lowered in elevation, the depth of moisture conditioning may need to be increased. Additionally, depending upon the depth of cut (if any), additional over -excavation and compaction may be required. Mitigation of Soil Corrosivity One sample of the upper 12 inches of existing fill soil from each lot was obtained and tested for pH, resistivity, soluble chloride, and soluble sulfate (results attached). This type of testing serves as an indicator as to the potential adverse effects of reinforcing steel, concrete, and buried pipes. The existing fill soils were found to have severe sulfate ion concentration (1,035 ppm) and moderate chloride ion concentrations (897 ppm). Sulfate ions can attack the cementitious material in concrete, causing weakening of the cement matrix and eventual deterioration by raveling. Chloride ions can cause corrosion of reinforcing steel. The Uniform Building Code requires for moderate sulfate conditions that Type II or V Portland Cement be used with a maximum water cement ratio of 0.45 using 4,500 psi concrete mix (UBC Table 19-A-4). A minimum concrete cover of 3 inches should be provided around steel reinforcing or embedded components exposed to native soil or landscape water (to 18 inches above grade). Additionally, the concrete should be thoroughly vibrated during placement. Electrical resistivity testing (195 ohm -cm) of the soil suggests that the site soils may present a very severe corrosion potential for metal loss from electrochemical corrosion processes. Corrosion protection of steel can be achieved by using epoxy corrosion inhibitors; asphalt coatings; cathodic protection; or encapsulating with densely consolidated concrete. We understand that there will not be any buried metal pipes in direct contact with the soil. We further understand that buried pipes will consist of plastic PVC or will be bituminous dipped, wrapped, or encased in PVC sleeves. Therefore, for the above stated conditions, it is our opinion that a specific corrosion analysis is not warranted since buried metal pipes will not be in direct contact with the soil. The contractor should exercise care during installation so not to nick the protective coating around any metal pipes. EARTH SYSTEMS SOUTHWEST JUN 2 3 2003 June 17, 2003 - 3 - File No.: 09225-01 03-06-770 Concrete Slabs -on -Grade Sub rg ade: Concrete slabs -on -grade and flatwork should be supported by compacted soil as discussed above and in the referenced geotechnical engineering report. Vapor Retarder: In areas of moisture sensitive floor coverings, an appropriate vapor retarder should be installed in order to reduce the potential for moisture transmission from the subgrade soil to the slab. The effectiveness of the moisture retarder is dependent upon the quality of the product, methodology/quality of the overlaps, protection of the retarder during construction, and the successful sealing off of the barrier around utility lines. We recommend that an impermeable membrane (6 -mil plastic) underlie the floor slabs. The membrane should be covered with 2 inches of sand to help protect it during construction and to aide in concrete curing. The 2 inches of sand is not intended to increase the thickness specified by the project architect or structural engineer. Rather the moisture retarder may be placed such that about 2 inches of sand is provided above and 2 inches of sand below the moisture retarder. The sand should be lightly moistened just prior to placing the concrete. Low -slump concrete should be used to help minimize shrinkage. Slab 'thickness and reinforcement: Slab thickness and reinforcement of slab -on -grade are contingent upon the structural engineer or architect's recommendations and the expansion index of the supporting soil. Based upon our findings, a modulus of subgrade reaction of approximately 200 pounds per cubic inch can be used in concrete slab design. Concrete slabs and flatwork should be a minimum of 4 inches thick (actual, not nominal). Concrete floor slabs may either be monolithically placed with the foundations or doweled after footing placement. However, the design engineer/architect should consider the potential adverse effects of temperature changes when providing recommendations for concrete slabs as well as the effects of a free floating slab versus slabs tied to the adjacent footings. The project architect or geotechnical engineer should continually observe all reinforcing steel in slabs during placement of concrete to check for proper location within the slabs and/or footings. Control Joints: Control joints should be provided in all concrete slabs -on -grade at a maximum spacing of 36 times the slab thickness (12 feet maximum on -center, each way) as recommended by American Concrete Institute (ACI) guidelines. All joints should form approximately square patterns to reduce randomly oriented contraction cracks. Contraction joints in the slabs should be tooled at the time of the pour or saw cut (1/4 of slab depth) within 8 hours of concrete placement. Construction (cold) joints should either be thickened butt joints with one-half inch dowels at 24 -inches on center or a thickened keyed joint to resist vertical deflection at the joint. All construction joints in exterior flatwork should be sealed to prevent moisture or foreign material intrusion. Precautions should be taken to prevent curling of slabs in this and desert region during the curing process. The contractor should take precautionary measures to ensure proper batching of the concrete, proper placement (without effecting the maximum water/cement ratio), proper finishing, and proper curing. These procedures will reduce the potential for randomly oriented cracks, however, may not eliminate them from occurring. JUN 2. 3 2003 EARTH SYSTEMS SOUTHWEST f June 17, 2003 - 4 - File No.: 09225-01 03-06-770 Seismic Design At a minimum, design of onsite structures should conform to the latest editions of the Uniform Building Code, or City/County codes, whichever is most restrictive. It should be noted that building codes are generally intended to protect human safety and prevent structural collapse. They are not necessarily intended to prevent structural damage or preserve functionality after a large earthquake. Therefore, more stringent seismic design should be considered if a particular level of structural performance is desirable after a large earthquake. That design_ should be based on a site and project specific seismicity analysis. The following are updated 1997 UBC seismic design values. Reference Seismic Zone: 4 Seismic Zone Factor, Z: 0.4 Soil Profile Type: Sp Seismic Source Type: A Closest Distance Known to Seismic Source: Andreas Fault -Southern) Near Source Factor Na: 1.04 Near Source Factor, Nv: 1.28 Figure 16-2 Table 16-I Table 16-S Table 16-U 9.0 km= 5.6 miles (San Seismic Coefficient, Ca: 0.46=0.44Na Seismic Coefficient, Cv: 0.82=0.64Nv Table 16-S Table 16-T Table 16-Q Table 16-R Except as mentioned above, it is our opinion that the referenced documents are applicable to the proposed development. We make no representation as to the accuracy of the dimensions, measurements, calculations, or any portion of the design. Should you have any questions concerning our addendum report please give us a call and we will be pleased to assist you. Sincerely, EARTH SY WEST A �. CE 38234 m EXP. 03/31/05 v Craig CE 38234 �TEOF Cgt�E�P Distribution: 4 Mies Development 1/RC File 2/BD File JUN 2 3 2003 EARTH SYSTEMS SOUTHWEST File No.: 09224-01 June 4, 2003 SOIL CHEMICAL ANALYSES Job Name: Retail Shops Pad M3 Job No.: 09224-01 Sample ID: Pad 3 Sample Depth, feet: 0-1' pH: 7.9 Resistivity (ohm -cm): 1.95 (saturated soil ) Chloride (Cl), ppm: 897 Sulfate (SO4), ppm: 1,035 Note: Tests performed by Subcontract Laboratory: Surabian Ag Laboratory and Consultants, Inc. 79-607 Country Club Drive. Bermuda Dunes, CA 92201 Tel: (760) 772-7995 General Guidelines for Soil Corrosivity Chemical Agent Amount in Soil Degree of Corrosivity Soluble 0 -1000 ppm Low Sulfates 1000 - 2000 ppm Moderate 2000 - 5000 ppm Severe > 5000 ppm Very Severe Resistivity , 1-1000 ohm -cm Very Severe 1000-2000 ohm -cm Severe 2000-10,000 ohm -cm Moderate 10,000+ ohm -cm Low EARTH SYSTEMS SOUTHWEST JUN 2 3 2003 TANDY'S INSPECTION INC. PO BOX 13766 PALM DESERT, CA 92255 SPECIAL INSPECTION DAILY REPORT OFFICE/FAX 909.769.9717 PAGER 760.776.3339 TYPE OF INSPECTION PERFORMED SAMPLE INFORMATION fREE (C o toc oicrVt. TICKET NUMBER 04 PHYSICAL ADDRESS PERMIT NUMBER *71 -q'163= 30 4t --3q3 JOB NAME TYPE OF STRUCTURE O %JC- E►J LA. �s.�TA C1�-�.f� E 2 (20 ARCHITECT ENGINEER c %.'L- y- F (::�') • 1(ZAr� GENERAL CONTRACTOR SUB CONTRACTOR a kc. Jam' PA cj,- DESCRIPTION av2J� o LE�t DF D vAoN o , coNCc�CE B `-t Vim--ct1�a � s � >2• o ! '1� 1 HEREBY CERTIFY THAT I HAVE INSPECTED ALL OF THE ABOVE REPORTED WORK, UNLESS OTHERWISE NOTED, AND TO THE BEST OF MY ABILITY I HAVE FOUND THIS WORK TO COMPLY WITH THE APPROVED PLANS, SPECIFICATIONS & APPLICABLE BUILDING LAWS. CC: TORS SIGNATURE INSPECTORS CERTIFICATION AGENCY AND NUMBER SAMPLE INFORMATION SUPPLIER TICKET NUMBER MIX NUMBER SAMPLED AIR TEMP SAMPLE TEMP SLUMP TIME IN MIXER sv�u►.)LXII q u t;So� - 05a $`..So "1 0911 a0 LOCATION Ce�`�Xw��=cxrsr,a 6 wy . M szbr oR "7 -0.w. WELDING INFORMATION PROCESS WELDERS NAME CERTIFYING AGENCY AND CERTIFICATION NUMBER 1 HEREBY CERTIFY THAT I HAVE INSPECTED ALL OF THE ABOVE REPORTED WORK, UNLESS OTHERWISE NOTED, AND TO THE BEST OF MY ABILITY I HAVE FOUND THIS WORK TO COMPLY WITH THE APPROVED PLANS, SPECIFICATIONS & APPLICABLE BUILDING LAWS. CC: TORS SIGNATURE INSPECTORS CERTIFICATION AGENCY AND NUMBER TANDY'S INSPECTION INC. PO BOX 13766 PALM DESERT, CA 92255 SPECIAL INSPECTION DAILY REPORT OFFICE/FAX 909.769.9717 PAGER 760.776.3339 TYPE OF INSPECTION PERFORME•D� SAMPLE INFORMATION DATE PHYSICAL ADDRESS 76--`lg Z 4 �� C Cf - -A PERMIT NUMBER 0307-32Q) 14 JOB NAME r/ //��y/�g� TYPE OF STRUCTURE 60 ARCHITECT t✓� fid.. L.e° ENGINEER jkr �iiR�(ii�11 �i1c GENERAL CONTRACTOR �B SUBCONTRACTOR ry I HEREBY CERTIFY THAT I HAVE INSPECTED ALL OF THE ABOVE REPORTED WORK, UNLESS OTHERWISE NOTED, AND TO THE BEST OF MY ABILITY I HAVE FOUND THIS WORK TO COMPLY WITH THE APPROVED PLANS, SPECIFICATIONS 8 APPLICABLE BUILDING LAWS. CC: INSPECTORS Sr.NATqtf l �L r tlC3Z(o� INSPECTORS CERTIFICATION AGENCY AND NUMBER SAMPLE INFORMATION DESCRIPTION OF WORK INSPECTED TICKET NUMBER MIX NUMBER —"""E E - I AIR TEMP SAMPLE AMPLED SLUMP TIME IN MIXER STEMP LOCATION WELDING INFORMATION PROCESS WELDERS NAME CERTIFYING AGENCY AND CERTIFICATION NUMBER 'R67f 06r, 17 Sib o SD I z so/ 2 JOf lj l (gD if _J' i�fS'Df f�/sf�� owtil #,S c,w Zvvsr, -A(07-6- ® 'Per, Z3 ,s0l -Ce7p; w 3 6b -ACT oS How Nwpl OT€ #3 LA -P JP t ts J, oj, eo®' lZ64, 2.° vv+%p.-), I HEREBY CERTIFY THAT I HAVE INSPECTED ALL OF THE ABOVE REPORTED WORK, UNLESS OTHERWISE NOTED, AND TO THE BEST OF MY ABILITY I HAVE FOUND THIS WORK TO COMPLY WITH THE APPROVED PLANS, SPECIFICATIONS 8 APPLICABLE BUILDING LAWS. CC: INSPECTORS Sr.NATqtf l �L r tlC3Z(o� INSPECTORS CERTIFICATION AGENCY AND NUMBER SAMPLE INFORMATION SUPPLIER TICKET NUMBER MIX NUMBER —"""E E - I AIR TEMP SAMPLE AMPLED SLUMP TIME IN MIXER STEMP LOCATION WELDING INFORMATION PROCESS WELDERS NAME CERTIFYING AGENCY AND CERTIFICATION NUMBER I HEREBY CERTIFY THAT I HAVE INSPECTED ALL OF THE ABOVE REPORTED WORK, UNLESS OTHERWISE NOTED, AND TO THE BEST OF MY ABILITY I HAVE FOUND THIS WORK TO COMPLY WITH THE APPROVED PLANS, SPECIFICATIONS 8 APPLICABLE BUILDING LAWS. CC: INSPECTORS Sr.NATqtf l �L r tlC3Z(o� INSPECTORS CERTIFICATION AGENCY AND NUMBER TANDY'S INSPECTION SERVICES, INC. PO BOX 13766 PALM DESERT, CA 92255-3766 SPECIAL INSPECTION REPORT OFFICE / FAX 909.769.9717 PAGER 760.776.3339 TYPE OF INSPECTION PERFORMED DATE CONCRETE I 16 -Jul -04 PHYSICAL ADDRESS PERMIT NUMBER 178.982'_17iI_GHWAY_-Ll-1- _-LA QUINTA- - & PUBLIC WORKS #4116 JOB NAME TYPE OF STRUCTURE RETAIL BUILDING @ ONE ELEVEN LA QUINTA CENTER COMMERCIAL ARCHITECT ENGINEER GENERAL CONTRACTOR SUBCONTRACTOR DESERT CITIES / CONSOLIDATED CONTR. M.C.0 DESCRIPTION OF WORK•INSPECTED 7/16 - CONSTRUCTED ONE SET OF 3 EA. CONCRETE TEST CYLINDERS FROM 1 ST AND ONLY LOAD OF A-1 REDI- MIX 4500 PSI CONCRETE. CONCRETE PLACED AT CATCH BASIN LOCATED IN NORTHWEST CORNER OF PROPERTY BY TRASH ENCLOSURE. REF. DET. 16 ON SHEET 1 OF PRECISE GRADING & PAVING PLAN. SAMPLE INFORMATION LOCATION I CATCH BASIN @ NORTHWEST CORNER OF PROPERTY SUPPLIER TICKET NUMBER MIX NUMBER TIME AIR TEMP SAMPLE SLUMP TIME IN WATER SAMPLED I I TEMP I MIXER ADDED A-1 6:00 AM 1 86° 1 80° 1 4" 1 , 0 I HEREBY CERTIFY THAT 1 HAVE INSPECTED ALL OF THE ABOVE REPORTED WORK, UNLESS OTHERWISE NOTED, AND TO THE BEST OF MY ABILITY 1 HAVE FOUND THIS WORK TO COMPLY WITH THE APPROVED PLANS, SPECIFICATIONS & APPLICABLE BUILDING LAWS. CC: Lo. ---Ri -L�ti lc -c_ l(ilsu e`+ INSPECTORS CERTIFICATION AGENCY AND NUMBER R '4' TANDY'S �- INSPECTION INC. PO BOX 13766 PALM DESERT, CA 92255 SPECIAL INSPECTION DAILY REPORT OFFICE/FAX 909.769.9717 PAGER 760.776.3339 TYPE OF INSPECTION PERFORMED DESCRIPTION OF WORK INSPECTED SUPPLIER mrir3s c4 sco• C -xoj6 �i--, iz- DATE J ,-PSS v4 r SAMPLE SLUMP TEMP TIME IN MIXER PHYSICAL ADDRESS_ PERMIT NUMBER R- _ 106 NAME TYPE OF STRUCTURE QUG U7L Ei QLA PROCESS CO wt VIA K Z ARCHITECT CERTIFYING AGENCY AND CERTIFICATION NUMBER E NEER Q ` �l-•1-.. ��� NERAL CONTRACTOR SUB CONTRACTOR I HEREBY CERTIFY THAT I HAVE INSPECTED ALL OF THE ABOVE REPORTED WORK, UNLESS OTHERWISE NOTED, AND TO THE BEST OF MY ABILITY I HAVE FOUND THIS WORK TO COMPLY WITH THE APPROVED PLANS, SPECIFICATIONS & APPLICABLE BUILDING LAWS. CC: i / I CTORS SIGNATURES 1 INSPECTORS CERTIFICATION AGENCY AND NUMBER DESCRIPTION OF WORK INSPECTED SUPPLIER mrir3s c4 sco• C -xoj6 �i--, iz- , 4 - ,-PSS v4 r SAMPLE SLUMP TEMP TIME IN MIXER tcGSrti�teG O t4( t1i T LOCATION WELDING INFORMATION PROCESS WELDERS NAME CERTIFYING AGENCY AND CERTIFICATION NUMBER I HEREBY CERTIFY THAT I HAVE INSPECTED ALL OF THE ABOVE REPORTED WORK, UNLESS OTHERWISE NOTED, AND TO THE BEST OF MY ABILITY I HAVE FOUND THIS WORK TO COMPLY WITH THE APPROVED PLANS, SPECIFICATIONS & APPLICABLE BUILDING LAWS. CC: i / I CTORS SIGNATURES 1 INSPECTORS CERTIFICATION AGENCY AND NUMBER SAMPLE INFORMATION SUPPLIER TICKET NUMBER MIX NUMBER AIR TEMP SAMPI ED SAMPLE SLUMP TEMP TIME IN MIXER LOCATION WELDING INFORMATION PROCESS WELDERS NAME CERTIFYING AGENCY AND CERTIFICATION NUMBER I HEREBY CERTIFY THAT I HAVE INSPECTED ALL OF THE ABOVE REPORTED WORK, UNLESS OTHERWISE NOTED, AND TO THE BEST OF MY ABILITY I HAVE FOUND THIS WORK TO COMPLY WITH THE APPROVED PLANS, SPECIFICATIONS & APPLICABLE BUILDING LAWS. CC: i / I CTORS SIGNATURES 1 INSPECTORS CERTIFICATION AGENCY AND NUMBER R F STRUCTURAL CoNmSUL.TANT.S:., INC. ------------------------------------------------------------ 44-100 MONTEREY AVE., SUITE 2.01C, PAU- 1 DESERT, CA. 92260 PHONE (760) 836-1000 FAX (760) 836-0856 E-MAIL R.FRANGIE@VER12QN.NET JUNE 3 0, 2004 CONSOLIDATED CONTRACTING, INC. 46=7-53 ADAMS STREET LA QUINTA, CA. 92253 Attn.: Mr.DAVE. SMOLEY Re.: THE RETAIL SHOPS, PAD M-3, LA QUINTA, CA. REVISION. JOB NO.: 4110 DEAR Mr. SMOLEY 73��'Z fel In regard of the. above_ mentioned ,project; and as per our phone.on. June 9, 2004, wesubmit the following: Follow the attached partial framing and foundation plans for the relocation of the ladder room at the fear of unit 1B. Verify the above information with the building department prior to application. If you have any questions please do not hesitate to call our office at the above listed phone number. Nasrallah Nicholas aboufadel attachment (5) [DATE 1 OF LA:EQTD NTA UILDING & SAEPT. APPRO�t NSTF Z O 8, SHELL2RZ �O CtVIL ENS+\ AgpOLP's F. U-FADEL tJo 50585 ."P. 9130105 78 " 1,8 2 MAY -07-2004 12:39 OM CARL COX I a I rp i w i N� 73 17 O P 0 760 347 9036 8.02 Np 131..011 to I tin 'a Tgbh ►n41 oN xda saiuedmoo UlIA04S WV 69;90 03M b00z-60-Nor MAY -07-2004 12:39 PM CARL COX 0- T60 34T 9036 P.03 Q.A 11 nn -i TC617T)InOi 'Ohl V14 saiuedmo, U Inoyq WH 8q: go 03M b00Z-60-NM D) ry HIGH TO LOW R00 10 ALL AROUND 314 e�fr GIRDS SD2 SD2 1 HIGH SOAK G GIRD 1 8 S D 2 0 _�--� �+�.�., o Q 6x6 Q� S� x Q Q 6x6 -IDR ----- — DR -- -- HR-- - 17 11 --- 17 11 1 11 L=15'-0" O L=9' L=71- ' — - - — 4x12 — 10 ALL AROUND TOP PLATE SPLICE r-+ --------------------------------- HDR _ ---------- HDR ---- _ _ _ _ _ _ _ _4x12.--------- �- TYP. HDR — — -� A'UND 10ALL ALL AROUND 16 GLB 24F V4 DFS Q 0 IT 11 SD1 5/8" x 12" A.B. @ 32" 0/C. 1 1 5/8" x 12" A.B. jDl N� @ 32" O/C. -(-v ----------------------- - ------ ----------DO - -------------- 11 11 11 17 3'-6" PAD EACF LATERAL ANALYSIS SHEAR WALL # 1 AT LEFT SHOP # 1 TOTAL LOAD = 394.25 x 76.00/2 = 14981.50 LBS. SHEAR WALL LENGTH = 43.00 FT. SHEAR WALL = 14981.50 / 43.00 = 348.41 PLF USE SHEAR WALL TYPE 11 WITH 5/8" x 12" A. B. AT 32" O/C. MAX DRAG LOAD = 3370.84 LBS. USE (24) 16D'S PER TOP PLATE SPLICE MAX. UPLIFT LOAD = 1732.89 LBS. USE SIMPSON HPAHD22 HOLDOWN EACH END. SHEAR WALL # 2 BTWN SHOP # 1 AND # 2 TOTAL LOAD = 394.25 x 151.00/2 = 29765.88 LBS. SHEAR WALL LENGTH = 48.00 FT. SHEAR WALL = 29765.88 / 48.00 = 620.12 PLF USE SHEAR WALL TYPE 13 WITH 5/8" x 12" A. B. AT 8" O/C WITH 2x SILL PLATE. MAX DRAG LOAD =3599.10 LBS. USE (26) 16D'S PER TOP PLATE SPLICE. MAX. UPLIFT LOAD = 6110.95LBS. USE SIMPSON HDBA HOLDOWN EACH END, WITH (2) # 5 BARS TOP AND BOTTOM 8'-0" PAST HOLDOWN EACH WAY. SHEAR WALL # 3 AT RIGHT OF SHOP # 4 TOTAL LOAD = 394.25 x 75.00/2 = 14784.38 LBS. SHEAR WALL LENGTH = 46.00 FT. SHEAR WALL = 14784.38 / 46.00 i 321.40 PLF USE SHEAR WALL TYPE 11 WITH 5/8" x 12" A..B. AT 32" O/C. MAX DRAG LOAD = 3203.28 LBS. USE (24) 16D'S PER TOP PLATE SPLICE MAX. UPLIFT LOAD = 1188.04 LBS. USE SIMPSON HPAHD22 HOLDOWN EACH END. SHEAR WALL # 4 AT REAR ELEVATION TOTAL LOAD = 651.70 x 70.00/2 = 26068.00 LBS. g,fl t i �q".t �- b SHEAR WALL LENGTH = 13.00 + 16.00 + 16.00 Y3-00 FT. SHEAR WALL = 26068.00 / 77.96 Mr'�A PLF 33Q.µ W. ZS USE SHEAR WALL TYPE 11 WITH 5/8" x 12" A. B. AT 32" O/C. d IL MAX DRAG LOAD = 310744 LBS. USE (22) 16D'S PER TOP PLATE SPLICE. &e' MAX. UPLIFT LOAD = 2497.14 LBS. USE SIMPSON BPAHD22 HOLDOWN EACH END, EACH PANEL