07-2170 (RC)P.O. BOX 1504
78-495 CALLE TAMPICO
LA QUINTA, CALIFORNIA 92253
Application Number:
07-00002170
Property Address:
78983 HIGHWAY 111
APN:
643-020-999-6 -30903 -
Application description:
REMODEL - COMMERCIAL
Property Zoning:
REGIONAL COMMERCIAL
Application valuation:
30000
T &-t 4 4 Qu&z
Applicant: Architect or Engineer:
------------------
LICENSED CONTRACTOR'S DECLARATION
BUILDING & SAFETY DEPARTMENT
BUILDING PERMIT
I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with
Section 7000) of Division 3 of the Business and Professionals Code, and my License is in full force and effect.
license Class: C34License No.: 821309
_
42��
Date: Contractor:
OWNER -BUILDER DECLARATION
1 hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the
following reason (Sec. 7031 .5, Business and Professions Code: Any city or county that requires a permit to
construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the
permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State
License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or
that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by
any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).:
(_ 1 I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and C
the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The
Contractors' State License Law does not apply to an owner of property who builds or improves thereon,
and who does the work himself or herself through his or her own employees; provided that the -
improvements are not intended or offered for sale. If, however, the building or improvement is sold within
one year of completion, the owner -builder will have the burden of proving that he or she did not build or
improve for the purpose of sale.).
(_) I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec.
7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of
property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed
pursuant to the Contractors' State License Law.).
( ) I am exempt under Sec. , B.&P.C. for this reason
7
Date: Owner:
CONSTRUCTION LENDING AGENCY
I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the
work for which this permit is issued (Sec. 3097, Civ. C.).
Lender's Name: (,/�
Lender's Address: T \ '
LQPEkMIT
Owner:
COST PLUS WORLD MARKET
200 4TH STREET
OAKLAND, CA 94607
(510)893-7300 .
VOICE (760) 777-7012
FAX (760) 777-7011
INSPECTIONS (760) 77777153
Date: 10/09/07
Contractor:
RPM INSTALLATIONS
5761 E. LA PALMA A
ANAHIEM, CA 92807
(714)528-5444
Lic. No.: 821309
-----------------------------------------------
WORKER'S COMPENSATION DECLARATION
I hereby affirm under penalty of perjury one of the following declarations:
I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided
for by Section 3700 of the Labor Code, for the performance of the work for which this permit is .
issued.
I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor
Code, for the performance of the work for which this permit is issued. My workers' compensation
insurance carrier and policy number are:
Carrier OAK RIVER INS Policy`Number 2210020317071
I certify that, in the performance of the work for which this permit is issued, 1 shall not employ any
person in any manner so:as to become subject to the workers' compensation laws of California,
and agree that, if I should become subject to the workers' compensation provisions of Section
��yy 3700 of the Labor a hall forthwith comply with those provisions.
-Dater I&IT-6-7
WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL
SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND
DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN
SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES.
APPLICANT ACKNOWLEDGEMENT
IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the
conditions and restrictions set forth on this application.
1 . Each person upon whose behalf this application is made, each person at whose request and foi
whose benefit work is performed under or pursuant to any permit issued as a result of this application,
the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City
of La Quinta, its officers, agents and employees for any act or omission related to the work being
performed under or following issuance of this permit.
2.• Any permit issued as a result of this application becomes null and void if work is not commenced
within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject
permit to cancellation.
certify that I have read this application and state that the above information is correct. 1 agree to comply with all
city and county ordinances and state laws relating to buildin istruction, and hereby authorise representatives
of this county to ernntt/er upon the above-mentioned pr y for in, ection purposes.
,Date: ��� I Signature (Applicant or Agent):
u
LQPERAiIT
Application Number .
. . . . OT -00002170
------ Structure Information
19293 SF SHELL - COST PLUS
-----
Other struct info . .
. . . CODE EDITION
01BMP04E05EN
FIRE SPRINKLERS
YES
MIXED-USE OCCUPANCY
M
OCCUPANT LOAD
.00
1ST FLOOR SQUARE FOOTAGE
19293.00
-------------------------------------------------
2ND FLOOR.SQUARE FOOTAGE
--------------------------
.00
Permit . . . BUILDING
PERMIT
Additional desc .
Permit Fee . . . .
284.50 Plan Check Fee
184.93
Issue Date . . . .
Valuation . . .
. 30000
Expiration Date
4/06/08
Qty Unit Charge
Per
Extension
BASE FEE
252.00
5.00 6.5000
THOU BLDG 25,001-50,000
-
32.50
---------------------------
Special Notes and Comments
---------------------------------
---------------
10 FT. STORAGE RACKS &
SHELVING FOR.
COST PLUS WORLD MARKET
RETAIL BUILDING.
2001 CBC.
------------=---------------------------------------------------------------
Other Fees . . . . .
. . . . ACCESSIBILITY PLAN REVIEW
36.98
STRONG MOTION (SMI) - COM
6.30
Fee summary Charged
----------------- -----
Paid Credited
----- ----------
Due
Permit Fee Total
---------- ----------
284.50 .00 .00
284.50
Plan Check Total
184.93 .00 .00•
184.93
Other Fee Total
43.28 .00 00
43.28
Grand Total
512.71 .00 .00
512.71
j -
- Permit #
City of La Quinta.
Btdidmg at Safety. Division
P.O. Box 1504, 78-495 Cage Tampion
1a Quinta, CAI= - (760) 777-7012
Building Permit Application and Tracking Sheet
Project Address: &
Owner's Name:✓La I2�f
A. P. Number.
TRACENG PERMIT FEES
Address: 766 q'0%
Legal Descriptiod:
Contractor.RPM VALt- d415 L-
Address: s E LA i�P, k.t--,n- AYk tO 32 %
City, ST, Zip: dlD r k \ P"r 9 fiO- q (o tS
Telephone. SI b $q 3 rJ WO - .• 3
Project Description r !a
City, ST, Zip: pilnr,Vea+n-, GY>r
�6
9—^-1 66, �i-t` t -i -rV.- .ST6C4au
Telephone: S2$514 4 `�
s " ? >. a.
'� s �/►�-f-t �r' Ow- W PK -
State Lic. # : 8Z ( Q -r
City Lic. #: �c tl
/-} t� cr;5 66� P-tr P' -*'•c✓ !r• -AU -5
Arch., Engr., Designer. _
Address:
City., ST, Zip: P6W� o A
1 6
[Name
elephon a $6 b 8' / Construction Type: Occupancy: X4�„ C
Project circle one ew Add'n Alter Repair Demo
ate Lia #: Z % % .;�, � ' .`'`. ,s�"`-' J tYPe � )� eP
of Contact Person: ZIA Sq. FL: Y2 9 j # Stories: #Units
Telephone # of Contact Person: 170 8 { 6 Estimated Value of Project: 30., Cd Q
APPLICANT: DO NOT WRITE BELOW THIS LINE
.i20 VCk DU -F— PC>MJ
Req'd
Rec'd
TRACENG PERMIT FEES
ffSubmittat
Plan Cheer; submitted 0
Item Amount
.Cales,
Reviewed, ready for corrections Plan Check Deposit
Truss Calcs.
. Called Contact Person Plan Check Balance.
Title 24 Calcs.
Pians picked up Construction
Flood plain plan
Pians resubmitted Mecthanirsl
Grading plan
21! Review, ready for eorrectio issue Electrical
Subcontactor List
Called Contact Person pPlumbing
Grant Deed
Plans picked up SM.L
H.O.A. Approval
Plans resubmitted Grading
INHOUSE:
''d Review, ready for correctionslissu I Developer Impact Fee
Planning Approval
Called Contact Person _ A.II P Y.
Pub, Wks. Appr
Date of permit issue "
School Fees
P
Total Permit Fees
.i20 VCk DU -F— PC>MJ
SEISMIC ANALYSIS
OF STORAGE RACKS
FOR
COST PLUS #334
78-983 HWY 111
LA QUINTA, CA 92253
Job No. 07-0545R
APPROVED BY
SALE. FATEEN, P.E.
4/11/2007
161 ATLANTIC STREET * POMONA * CA 91768 * TEL: (909) 869-0989 * FAX: (909) 869-0981
-
SEIZMIC
MATERIAL HANDLING ENGINEERING
=
EST. 1985
ALASKA
KENTUCKY
NORTH CAROLINA
STORAGE RACKS
STEEL SHELVING
SEISMIC ANALYSIS
ARIZONA
MARYLAND
OHIO
DRIVE-IN RACKS
MOVABLE SHELVING
STRUCTURAL DESIGN .
CALIFORNIA
MASSACHUSETTS
OKLAHOMA
CANTILEVER RACKS
STORAGE RACKS
CITY APPROVALS
COLORADO
MICHIGAN
OREGON
MEZZANINES
MODULAR OFFICES
STATE APPROVALS
CONNECTICUT
MINNESOTA
PENNSYLVANIA
CONVEYORS
GONDOLAS
PRODUCT TESTING
FLORIDA.
MISSOURI
TENNESSEE
CAROUSELS
BOOKSTACKS
FIELD INSPECTION
GEORGIA
MONTANA
TEXAS
PUSHBACK RACKS
FLOW RACKS
SPECIAL FABRICATION,
IDAHO
NEBRASKA
UTAH
RACKBUILDINGS
FOOTINGS
PERMITTING SERVICES
ILLINOIS
NEVADA
VIRGINIA
INDIANA
NEW JERSEY
WASHINGTON
'
KANSAS
NEW MEXICO
WISCONSIN
SEISMIC ANALYSIS
OF STORAGE RACKS
FOR
COST PLUS #334
78-983 HWY 111
LA QUINTA, CA 92253
Job No. 07-0545R
APPROVED BY
SALE. FATEEN, P.E.
4/11/2007
161 ATLANTIC STREET * POMONA * CA 91768 * TEL: (909) 869-0989 * FAX: (909) 869-0981
SEMMIC
MATERIAL HANDLING ENGINEERING
TEL: (909)869 - 0989 FAX: (909)869 - 0981
PROJECT COST PLUS #334
FOR RPM INSTALLATIONS, INC.
SHEET NO. 2
CALCULATED BY TC
161 ATLANTIC STREET, POMONA, CA 91768 VAI L 4i i iiwu i
TABLE OF CONTENTS
SCOPE:
THIS ANALYSIS OF THE STORAGE SYSTEM IS TO DETERMINE ITS
COMPLIANCE WITH THE APPROPRIATE BUILDING CODES WITH RESPECT TO
STATIC AND SEISMIC FORCES.
THE STORAGE RACKS ARE PREFABRICATED AND ARE TO BE FIELD
ASSEMBLED ONLY, WITHOUT -ANY FIELD WELDING.
e-SEIMP PROJECT
. FOR
MATERIAL HANDLING ENGINEERING SHEET NO.
TEL: (909)869 - 0989 FAX : (909)869 - 0981 CALCULATED BY
161 At LAN l IL; J 1 Kt t l, YUMUNA, L A y 1 roa
aits, i r
COST PLUS #334
RPM INSTALLATIONS, INC.
3
TC
THE STORAGE RACKS CONSIST OF SEVERAL BAYS, INTERCONNECTED IN ONE OR BOTH DIRECTIONS, WITH THE
COLUMNS OF THE VERTICAL FRAMES BEING COMMON BETWEEN AND ADJACENT BAYS.
THE ANALYSIS WILL FOCUS ON A TRIBUTARY BAY TO BE ANALYSED IN BOTH THE LONGITUDINAL AND
TRANSVERSE DIRECTION.
STABILITY IN THE LONGITUDINAL DIRECTION IS MAINTAINED BY THE BEAM TO COLUMN MOMENT RESISTING
CONNECTIONS, WHILE BRACING ACTS IN THE TRANSVERSE DIRECTION.
CONCEPTUAL DRAWIN
LEGEND
1. COLUMN
2. BEAM
3. BEAM TO COLUMN '
4. BASE PLATE
5. HORIZONTAL BRACING
6. DIAGONAL BRACING
7. BACK TO BACK CONNECTOR
*ACTUAL CONFIGURATION SHOWN ON COMPONENTS & SPECIFICATIONS SHEET
5
E
IC
MATERIAL HANDLING ENGINEERING
TEL: (909)869 - 0989 FAX: (909)869 - 0981
1 L 1 ATT A XTT fl 0 nv -r nllh.f/-0,1 A OA 01'744
PROJECT COST PLUS #334
FOR RPM INSTALLATIONS, INC.
SHEET NO. 4
CALCULATED BY TC
nATF. 4111 /2007
1V1 h1 Lt11V 11V J11WL1 1 V1vAV1�n v
-----
-- ---
COMPONENTS & SPECIFICATIONS : N.I.C. RACKING
ANALYSIS PER CHAP 22, DIV X OF THE 2001
CBC
W2
Y1 =42 in.
LEVELS = 2 H1= 60 in.
H2 = 36 in.
W1 =800 lbs.
W2 =800 lbs.T Y2 = 42 in.
Y3 = 24 in.
PANELS =`3
Y3
LIVE LOAD = 800 lbs.
H2
FRAME HEIGHT =1.20 in. ,
H W 1
H Y2
FRAME DEPTH = 42 in.
BEAM LENGTH= 96 in.
H1
ZONE=Zone4 (Na=•1.1)
Y1
TYPE = SINGLE ROW
/
COLUMN
BEAM @ Level 1
CONNECTOR @ Level 1
OK
OK
OK
Tube 3x1-5/8x13ga
StepBeam 4.5"x2.5"x15ga
TWO PIN CONNECTOR
Steel = 55000 psi
Steel = 55000 psi
Stress =i 4-%
Stress =21%
Max Static Capacity = 5642 lb.
Static Stress = 14% Seismic Stress = 8%
COLUMN BACKER
BEAM @ Level 2+
CONNECTOR @ Level 2+
OK
OK
StepBeam 4.5"x2.5"xl5ga
TWO PIN CONNECTOR
None
Max Static Capacity = 5642 lb.
Stress =(�%
Stress =
Static Stress = 1.4% Seismic Stress = 3%
BRACING
SLAB & SOIL
OK
OK
Slab = 5" X 2500 'psi OK
HORIZONTAL DIAGONAL
Soil Bearing Pressure = 1000 psf
1 1/2 X 20 GA (SQ. TUBE) 7/8
X 20 GA (PIPE)
Slab Puncture Stress = 19%
Stress = 6%
Stress =1.1%
Slab Bending Stress = 8%
BASE PLATE
ANCHORS
OK
Ramset/Redhead Trubolt 0.5 Dia. X 2.25 Min. Embd. OK
3.0 in X 3.0 in X 0.125 in
Pullout Capacity = 580 lbs.
Steel = 36000 psi
Shear Capacity = 1190 lbs.
MBase = 0 in. lb.
No. Of Anchors = 1 per Base Plate
Stress =32%
or approved equal) Anchor Stress = 4%
• SEMMIC
MATERIAL HANDLING ENGINEERING
TEL: (90§)869 -0989 FAX': (909)869 - 0981
PROJECT
FOR
SHEET NO.
CALCULATED BY
COST PLUS #334
RPM INSTALLATIONS, INC.
5
TC
L SEMMIC
MATERIAL HANDLING ENGINEERING
TEL: (909)869 - 0989 FAX : (909)869 - 0981
PROJECT COST PLUS #334
FOR RPM INSTALLATIONS, INC.
SHEET NO. 6
CALCULATED BY TC
161 Al LAN I IU b l K> t I, YUMIL) N A, LA Y l /05 Lr+ • r.
LONGITUDINAL ANALYSIS: N.I.C. RACKING
THE ANALYSIS IS BASED ON THE PORTAL METHOD, WITH THE POINT OF CONTRA FLEXURE OF THE COLUMNS
ASSUMED AT MID -HEIGHT BETWEEN BEAMS, EXCEPT FOR THE LOWEST PORTION, WHERE THE BASE PLATE
PROVIDES ONLY PARTIAL FIXITY, THE CONTRA FLEXURE IS ASSUMED TO OCCUR CLOSER TO THE BASE. (OR
AT THE BASE FOR PINNED CONDITION, WHERE THE BASE PLATE CANNOT CARRY MOMENT).
Mn -n Fn
MUpper + MLower — MConn'R' + MConn'L'
_ M5-5
MConn'R' MConn'L' M4-4 S
F
MConn 2 —MUpper +MLower 4
_ MUpper + MLower M3-3
__Z 7"
Mconn _ 2 + MEnds 71 F3
M2-2 2
VLong Ml -1
VCoI 2 = 771bs Fl
M base
MBase — 0 in/lb MEnds — 864 in/lb
FRONT ELEVATION
LEVELS
hi
f
AXIAL LOAD
MOMENT
Mconn
1
2
58
36
30
48
900
450
4,466
846
3,520
1,287
SAMPLE( CALC.
Ml -1 (VCol - hi) - MBase
_ (77 lbs X 58 in) - 0 in/lb = 4,466 in/lb
SEMMIC
MATERIAL HANDLING ENGINEERING
TEL: (909)869 - 0989 FAX: (909)869 - 0981
—I A— AITTT/ o[ rnvo-r ni-A AnXTA (`A 01^1(.4
PROJECT COST PLUS #334
FOR RPM INSTALLATIONS, INC.
SHEET NO. 7
CALCULATED BY TC
nATF 4/11/2007
COLUMN ANALYSIS: N.I.C. RACKING
ANALYZED PER DIV VII, CHAP 22 OF THE 2001 CBC. SECTION PROPERTIES BASED ON THE EFFECTIVE SECTION.
P = 900 lbs
M = 4466 in/Ib
Kx ' Lx
1.2 X 58in / 1.125m
Rx = 61.9 KL Max = 66.6
R
Ky'Ly = 1 X42in/0.631in'
Ry = 66.6 „
Axial r12 E65.7 = = 65.7 KSI
FQ .
k l rMax
Fy = 28 KSI
2 Since: Fe > `Fy /2 .
F = 55 KSI X [1 - 55 KSI / (4 X 65.71751KSI)]
P, = Fy 1— y
4 • Fe = 43.5 KSI
Pn=.Aeff F, = 0.646 in^2 X 43.5 KSI = 28096 Ibs
Pa"c = 28096 lbs / 1.92 = 14633 lbs
'p
0.06
Pa
Flexure
Since: P <0.15 Check: P + Cmx Mx <-1.33,
Po Pp Max ' px
Myield = My = Sx Fy = 0.545 In^3 X 55000 PSI = 29975 in/Ib
Max = 1Py = 29975 / 1.67 = 17949 in/lb
Of
= (3.14159)^2 X 29500 KSI X 0.8178 / (69.6 = 49153lbs
1 ,
�x = P = (1 / (1 - (1.92 X 900 lb / 49153 1b)))^ -I = 0.96
Pcr
(900 lb / 14633 lb) + (4466 in/lb / 17949 in/lb) = 0.28 < 1.33 (21%)
�A�
B
SECTION PROPERTIES
A 3 in
B 1.625 in
t
: 0.09 in
Aeff : 0.646 in^
Ix
: 0.8178 in^4
Sx
: 0.545 in/3
Rx
:1.125 in
Iy
: 0.257 in^4
Sy
: 0.267 in^3
Ry
: 0.631 in
Kx
:1.2
Lx
: 58 in
Ky
:1
Ly
:42 in
Fy
:55 KSI
E
: 29500 KSI
QC: 1..92
f2f: 1.67
Cmx : 0.85
Cb : 1
SEIZMIC
MATERIAL HANDLING ENGINEERING
TEL: (909)869 - 0989 FAX: (909)869 - 0981
101 A1LANHU JIK1',h1, YVMVNA, UA Y1 ioa
PROJECT COST PLUS #334
FOR RPM INSTALLATIONS, INC.
SHEET NO. 8
CALCULATED BY TC
A //
BEAM ANALYSIS: N.I.C. RACKING
BEAM TO COLUMN CONNECTIONS PROVIDE ADEQUATE MOMENT CAPACITY TO STABLIZE THE SYSTEM,
ALTHOUGH IT DOES NOT PROVIDE FULL FIXITY. THUS, THE BEAMS WILL BE ANALYSED ASSUMING PARTIAL END
FIXITY. FOR THE COMPUTATION OF BEAM TO COLUMN MOMENT CAPACITY, THE PARTIAL END FIXITY MOMENT OF
THE BEAM WILL BE ADDED TO THE LONGITUDINAL FRAME MOMENT FOR THE ANALYSIS OF THE CONNECTION.
EFFECTIVE MOMENT FOR PARTIALLY FIXED BEAM
For a simply supported beam, the max moment at the center is given by WL V8 . An assumption of partial fixity will decrease
this maximum moment by the following method.
Percentage of End Fixity =. 25% = 0.25 Mcenter(sim0e)
MCenter = MCenter(Simple ends) - 6*MCenter(Fixed ends) Mends Mcener
(fes (fixed)
W1 2/8 - (0 • 7 2 /12) = 0.104.97' T -'f •.
��uiiilllllllllll I II Ilii i o u �„
Reduction Coefficient R = 0.104/0.125 = 0.833
- -
MCenter — p' g72 l8 =0.833 • W12/$ L
MEnd¢ = 0 • Mm. �T ixedEnds). = W7? /12 - 0.25 L
= 0.0208 • ffq2 TYPICALBEAM FRONT VIEW
EFFECTIVE DEFLECTION FOR PARTIALLY FIXED BEAM
For a simply supported beam, the max deflection at the center is given by597 °/384 EI .
An assumption of partial fixity will .decrease this maximum deflection by the following
method.
_ SWl4
�"'� —� 384•E•IX
LiveLoad / 1v1= 800 lbs
DeadLoad 11vl =4lb/ft X 2 X (96/12) = 64 lbs
= 0.104 * gq 21 = 4320 in/Ib
MCenter —
MEnds = 0.0208* p72 = 864 in/lb
Fb = 0.6 • Fy = 33000 PSI
FBEff. = 33000 PSI
0
SEIMIC
MATERIAL HANDLING ENGINEERING
TEL (909)869 - 0989. FAX: (909)869 - 0981
,. I
101 t11 Lt11v l I%, J 1 MUi t, • W---' v
BEAM ANALYSIS: N.I.C. RACKING
MAXIMUM STATIC LOAD PER LEVEL DEPENDS ON:
1. MAXIMUM MOMENT CAPACITY
Fb M/Sx
FBEf = SX
Max.Weight / lvl = FBE$.-• 16-S,,_. a
8-L
_ ((33000 X 16 X 0.977) / (0.833 X 96)) X 0.875 = 5642 Ibs/lvl
2. MAXIMUM ALLOWABLE DEFLECTION
Darraw L1180 0.533 In
S4
Wl •
�= 384•E•Ix
Max.Weight / M = 384 • E • Ix ' AArraw • L3
5-48
PROJECT COST PLUS #334
FOR RPM INSTALLATIONS, INC.
SHEET NO. 9
CALCULATED BY TC
neTF. 4/11/2007
I = 2.294 in^4 S = 0.977 in^3
x x
Fy =55000 PSI a(impactCoefficient) = 0.875
_ 0.833 0.25
(Length) = 96 in in Lu = 96 in
Step = 1.625 in BeamThickness = 0.0673 i
• BeamDepth = 4.5 in
TopWidth = 1.75 in Bottom Width= 2.5 in
_ ((384 X 29000000 X 2.294 X 0.533) / (5 - (4 X 0.25))) X 96^3 = 7700 Ibs/lvl
MAXIMUM ALLOWABLE LIVE LOAD PER LEVEL = 5642lbs/lvl BeamStress = 14%
ALLOWABLE AND ACTUAL BENDING MOMENT AT EACH LEVEL
=
MArraw,sersmrc `sx * Fb * 1.33
Mstatic = W12/8
MArraw,sraric =S, * Fb
Mlmpact = Mstalic * 1.125
Mseismic
= Mconn
Level
Mstatic
MImpaet
MA11ow,statie
Mseismio
MA1ow,seismic
Result
1
4320
4860
32241
3520
42988
GOOD
2
4320
4860
32241
1287
42988
GOOD
SEUMIC
• INC.
MATERIAL HANDLING ENGINEERING
TEL: (909) 869-0989 • FAX: (909) 869-0981
161 ATLANTIC AVENUE • POMONA, CA 91768
PR03ECT COST PLUS #334
FOR RPM INSTALLATIONS, INC.
SHEET NO. 10
CALCULATED BY TC
DATE 4/11/2007
BEAM TO.COLUMN CONNECTION: SPEEDRACK
Mconn = (Mlower + Mupper)/2 + Mend
CAPACITY OF CONNECTOR:
A) SHEAR CAPACITY OF 3/8"O.PIN (DOUBLE SHEAR):
PIN DIA. = .375 in
Area = (0.375)^2*n/4
= .1104 in^2 Moc
Fy= 55,000 psi (MIN.)
Pmax= Area * Fv * 2 (DOUBLE SHEAR)
= 4,860 Ib
B) BEARING ON COLUMN (DOUBLE SHEAR):
Fy= 50,000 psi
Fu= 65,000 psi
t min= .09 in (13 GA.) .
Abrg.= t * D
_ .0338 in^2
Pmax brg.= (Pn/II) * 2 (DOUBLE SHEAR)
= (Fp*Abrg/C2) * 2 (DOUBLE SHEAR)
= (2.22Fu * Abrg/2.22) * 2 (DOUBLE SHEAR)
= Fu * Abrg * 2 (DOUBLE SHEAR)
= 4,388 Ib < 4860 Ib
C) MOMENT CAPACITY OF BRACKET:
D=4. in
IINIMUM P1 VALUE GOVERNS P1= 4,388 Ib
Mconn. cap.= Pmax x D x 1.33
= 4388 Ib'* 4 in * 1.33
= 23,342 in -Ib
Mupper
/-��
Nl—J
Mlower
R"
ICKING Pll`
t-SE1ZM1C
MATERIAL HANDLING ENGINEERING
r
TEL: (909)869 - 0989 FAX: (909)869 - 0981
PROJECT COST PLUS #334
FOR RPM INSTALLATIONS, INC.
SHEET NO. I 1
CALCULATED BY TC
DATE 4/11/2007
T IS ASSUMED THAT THE LOWER PANEL RESISTS THE FRAME SHEAR IN TENSION AND COMPRESSION.
F HORIZONTAL AND DIAGONAL MEMBERS ARE THE SAME, ANALYSIS WILL BE DONE ON THE
IAGONAL MEMBER AS IT WILL GOVERN.
i
IAGONAL BRACING : TENSION MEMBER
Ldiag = JL — 6)2 + (D - Q • BCoI ))Z = 54.8" o P. I
Vdia Prans • Mag
b' - d = 461 Ibs
At = o. (o F y = 33000
Brace Stress =
i
0.15 < 1.33 (11 %)
SIDE ELEVATION
Panel Height (L) =
42 In
Panel Depth (D) =
42 In
Column Depth (B) =
1.625 In
Clear Depth (d) _ (D - 2*13) =
0.
SUMP
MATERIAL HANDLING ENGINEERING
TEL: (909)869 - 0989 FAX: (909)869 - 0981
.1. .m. •- c.Tn--T nnXAr%'KTA fl AI'7LQ
PROJECT COST PLUS #334
FOR. RPM INSTALLATIONS, INC.
SHEET NO. 12
CALCULATED BY TC
DATE. 4/11/2007
OVERTURNING ANALYSIS: N.I.C. RACKING
ANALYSIS OF OVERTURNING WILL BE BASED ON SECTION 2228.7.1 OF THE 2001 CBC.
FULLY LOADED
Total Shear = 354 lbs
Movt =V runs Ht -1.15
Mout = 354 X 82 X 1.15 = 33382 in/lb
Mst = (Wp +.85wDL)• d/2
_ (1600+(.85 X 200)) X 42/2 = 37170 in/lb
Mst
r _ 1 (33382-37170)/42
PupL;ft = 14—m
Mst 1 -90 lbs. Puplift <= 0 No Up Lift
TOP SHELF LOADED
Shear = 196 lbs
MQvt = Vtop • Ht • 1.15
Vl
1 = 196 X 96 X 1:15 = 21686 in/Ib
ovt
'Mst(Wp+wDL)•d/2
M (800 + (.85 X 200)) X 42 /2 = 20370 in/lb
st
P _ 1(Movt — Mst / _ (21686 - 20370) / 42
UpL+lt — d
31 lbs:
ANCHORS
No. of Anchors : I
Pull Out Capacity: 580 Lbs.
Shear Capacity : 1190 Lbs.
COMBINED STRESS
Fullv Loaded (0�/ 580 X 1))+ ((354 /2)/(1190 X 1)) = 0.04
Top Shelf Loaded (31 / (580 X 1))+ ((196 /2)/(1190 X 1)) = 0.02
USE 1 Ramset/Redhead Trubolt 0.5 Dia. X 2.25 Min. Embd. Anchors.per BasePlate.
(or approved equal)
W
CROSS AISLE ELEVATION
Fr
i
V
SEIZMIC PROJECT COST PLUS #334
INC... FOR RPM INSTALLATIONS, INC:
SHEET NO. 13
MATERIAL HANDLING ENGINEERING CALCULATED BY TC
TEL: (909) 869-0989 • FAX: (909) 869-0981 DATE 4/11/2007
161 ATLANTIC AVENUE • POMONA, CA 91768
BASE PLATE ANALYSIS: TYPE "N.I.C. RACKING"
TRANSVERSE DIRECTION (CROSS AISLE LOADS) L' Beff
Pcol (LL+DL) = Pstatic= 900 LB
-Pseismic = (Movt*1.15/D)= 795 LB
Pcol = Pcol + (Mot/D)
= 1,695 LB
CHECK BENDING CAPACITY
BASE PLATE WIDTH (W)= 3. IN
-T
1
HOLE 0 = 0.5625 I
EFF.BASE PLATE DEPTH (B)= 2.0938 IN GE TO CENTER LINE (L) = 0.625 IN
b = 1.625 IN
PCOI
b1 = .4688 IN
THICKNESS (t) = 0.125 IN
Fy = 36,000 PSI
• fa = P/A
= Pcol/((D)(B)) .
= 270 PSI
b
b1
Mbase= (W/in)(L^2)/2
EFFECTIV
= (fa*1"STRIP)(b1^2)/2
E
= 29.65 IN -LB
Sbase = (1)(t^2)/6
_ .0026 INA 3
:j.,.
m
Fbase = (0.75)(Fy)1.33
= 35,910 'PSI
fb/Fb = Mbase/((Sbase)(Fbase))
= 0.32 < 1.00 OK
SEMMIC
MATERIAL HANDLING ENGINEERING
TEL: (909)869 - 0989 FAX: (909)869 - 0981
PROJECT COST PLUS #334
FOR RPM INSTALLATIONS, INC.
SHEET NO. 14
CALCULATED BY TC
161 ATLANTIC STRE 11 YUMUNA, CA Y1768
LM 11 r. Y, i iicvv i
SLAB AND SOIL: N.I.C. RACKING
THE SLAB WILL BE CHECKED FOR PUNCTURE STRESS. IF NO PUNCTURE OCCURS, IT WILL BE
ASSUMED TO DISTRIBUTE THE LOAD OVER A LARGER AREA OF SOIL AND
WILL ACT AS A FOOTING.
PUNCTURE
B= B•W +t
Parotic = 900 lbs Mot =
33382.2 in -lb p
Pm. =1.1 • (1.2 • Pa,a„c + 1.0 • (Mot l d )) =
2062 lbs
Fpunct _ 2 • f, =
— C ,
100 PSI
1 ( 1
Apunct = B + t I + I W+ t I •2 • t =
C )\
111 sq. in.
4B
J
J v • Pmax
b
= =
Fv Apunct • Fpunct
0.19
SLAB TENSION
10 L
P • 144
2 2
wb fsoir ' b
Asoi(— max.
= 223 sq. in.
1.33 • fl
= in -lb
L = Aso,,
B = 3.0 in
= 14.94 in
W = 3.0 , in
B= B•W +t
= 8.05 in
-
Frame Depth d = 42 in
L B
b =
= 3.45 in
CONCRETE
2
2 2
wb fsoir ' b
fc = 2500 PSI
—1.33 55
M =
= in -lb
`°nc - 2 144.2
t = 5 in.
2
1
Sconc =
= 4.17 Cb. in.
0 = 0.65
6
F = 50 f'
SOIL
cont c
= 162.5 PSI
fb MConc
fSoll = 1000 PSF
=
= 0.08
Fb SConc • FConc
OK
K
SEIZMIC PR07ECT ` COST PLUS #334
wC FOR RPM INSTALLATIONS, INC.
SHEET NO. 15
MATERIAL HANDLING ENGINEERING CALCULATED BY TC
TEL: (909) 869-0989 • FAX: (909) 869-0981 DATE 4/11/2007
161 ATLANTIC AVENUE • POMONA, CA 91768
LIGHT DUTY STORAGE FIXTURES
TYPE (120"H x 48"W x 18"D)
3
SHELVES
T
SEI
ZMIC
INC.
MATERIAL HANDLING ENGINEERING
..TEL: (909) 869-0989 • FAX: (909) 869-0981
161 ATLANTIC AVENUE POMONA, CA 91.768
PROJECT COST PLUS #334
FOR RPM INSTALLATIONS, INC.
SHEET NO. 16
CALCULATED BYTC
DATE 4/11/2007
SCOPE LIGHT DUTY STORAGE FIXTURE UNITS: WALL BRACE ANALYSIS
THE PURPOSE OF THIS ANALYSIS IS TO SHOW THAT THE FOLLOWING LIGHT DUTY STORAGE
FIXTURES COMPLIES WITH THE REQUIREMENTS SET FORTH IN THE 1997 UBC/ 2001 CBC. THE CRITICAL
CONFIGURATION TO BE ANALYZED, SINCE ALL MEMBERS AND LOADING ARE THE SAME WITHIN
EACH UNIT "TYP-P" IS THE CRITICAL CONFIGURATION ANALYZED.
PARAMETERS
STEEL- 36,000 PSI. (WHEN USED)
ANCHORS- 1/4"0x2" MIN. EMBED. REDHEAD TRUBOLT (ICC #ER -1372)
OR APPROVED EQUAL.
SLAB- 5 IN x 2500 PSI-
SOIL- 1,000 PSF
CRITICAL CONFIGURATION: TYPE (120"H x 48"W x 18"D)
-- 48"
38"
38"
38"
T
48 m
cn
72"X48"
GRID
G
M
72"
12"X48" BASE LEDGER
INSTALL BY CONTRACTOR
co
M
12"
CDMIT%IIC%A1 .;" QITC VICIA/
TYPICAL LIGHT DUTY STORAGE FIXTURE ELEVATION
j=S=ElZMl=C PROJECT COST PLUS #334
INC- FOR RPM INSTALLATIONS, INC..
SHEET NO. 17
MATERIAL HANDLING ENGINEERING CALCULATED BYTC
DATE 4/11/2007
TEL: (909) 869-0989 • FAX: (909) 869-0981
t
161 ATLANTIC AVENUE • POMONA, CA 91768
LOADS & DISTRIBUTION: TYPE (120"H x 48"W x 18"D)
ANALYSIS PER 1997 U.B.C./ 2001.C.B.C., SECTION 1632.2
100 LB/LVL <__= LIVE LOAD
10 LBILVL <__= DEAD LOAD
Fp= ap x Ca x Ip x Wp/ Rp <__= EQN. 32-2
= 0.7 * Ca * Ip * Wp <__= EQN. 32-3
NOTE: SINCE ap x.Ca x Ip x Wp/ Rp < 0.7 * Ca * Ip * Wp; MAXIMUM EQN. IS 32-3 (CONT
Fp=0.7*Ca*Ip*Wp
Ca= 0.484 WHERE Ca = 0.44Na AND Na = 1.1
Ip= 1
Rp= 4
Wp(total)= Wp(LL)/n + Wp(DL)
Wp(LL)= 100 LB/LVL
Wp(DL)= 10 LB/LVL
# OF LVLS= 3
1.4' <__= WORKING STRESS REDUCTION
TRANSVERSE DIRECTION
Vtrans= 0.7 * 0.484 * 1 * (100 LB + 10 LB )*3 LVLS/1.4
= 79.86 LB <__= TRANSVERSE SEISMIC SHEAR PER FRAME
LONGITUDINAL DIRECTION
Vlong= 0.7 * 0.484 * 1 * 100 LB + 10 LB )*3 LVLS/1.4
79.86 LB <__= LONGITUDINAL, SEISMIC SHEAR PER FRAME
3"
SIDE VIEW
LATERAL FORCE DISTRIBUTION
LEVEL
wx(DL+LL)
hx
wxhx
Fi
Fi*hx*1.15
1
2
3
110 LB/LVL
110 LB/LVL
110 LB/LVL
6.0 IN
38.0 IN
76.0 IN
660
4180
8360
3.99 LB
25.29 LB
50.58 LB
27.6 IN LB
1105.1 IN LB
4420.5 IN LB
=
13200 IN -LB
= 79.86
5553.2 IN LB
= Movt
'SEIZMIC
INC.
MATERIAL HANDLING ENGINEERING
TEL: (909) 869-0989 • FAX: (909) 869-0981
IAl ATI ANTIC: AVFNIIF • POMONA. CA 91768
PROJECT COST PLUS #334
FOR RPM INSTALLATIONS, INC:
SHEET NO. 18
CALCULATED BY TC
DATE 4/11/2007
WALL ADEQUACY ANALYSIS: TYPE (120"H x 48"W x 18"D)
WALL LATERAL -LOAD = 5 PSF (PER SECTION 1611.5 OF THE 1997 UBC/ 2001 CBC)
WALL AREA/UNIT = (120 IN) * (481N)
= 5,760 IN^2
= 40 FT^2
WALL CAPACITY = WALL LATERAL LOAD " (WALL AREA/UNIT)
= 5 PSF * 40 FT^2
= 200 LB
Vwall= Vtrans
= 80 LB < 200 LB THEREFORE WALL IS ADEQUATE TO RESIST SEISMIC LOADS.
CONNECTION TO WALL ANALYSIS: TYPE (120"H x 48"W x 18"D
WITHDRAWAL FORCE ON WALL CONNECTION= T
CONNECTION HEIGHT= 120. IN
Mot = y(Fi * Hi) * 1.15
= 4829" IN -LB "1.15
= 5,553.2 IN -LB
Mst = Z[(LIVE LOAD + 0.85*DEAD LOAD)*(D/2)]
= 3 LEVELS * (100 LB/LVL + 0.85*10 LB/LVL) * 18 IN/2
= 2,929.5 IN -LB
T = (Mot - Mst)/(HEIGHT OF CONNECTION)'
= 21.9 LB <= WITHDRAWAL
CHECK TENSION CAPACITY OF 1/4"0 X 3/4" EMBED. LAG SCREW
CONN TYPE = 1/4"0 X 3/4"
P(SCREW) = 110 LB (PER 1997 NDS, TABLE 9.2A, PAGE 78)
SINCE 21.9 LB < 110 LB THEN WALL ATTACHMENT IS SUFFICIENT TO RESIST SEISMIC FORCES:
NOTE:, SHOULD WALL BE CONSTRUCTED OF METAL STUDS, # 10 SHEET METAL SCREWS SHOULD BE
USED FOR CONNECTION.
ESSEIMIC
MATERIAL HANDLING ENGINEERING
TEL: (909) 869-0989 * FAX: (909) 869-0981
161 ATLANTIC AVENUE * POMONA, CA 91768
PROJECT COST PLUS #334
FOR RPM INSTALLATIONS, INC.
SHEET NO. 19
CALCULATED BY TC
DATE 4/11/2007
OVERTURNING/ANCHORAGE ANALYSIS: TYPE (120"H x 48"W x 18"D)
TOTAL DEPTH= 18 IN
(A) FULLY LOADED:
Vtotal = 79.9 LB
Vcol= 39.9 LB
Movt = Z(Fi * Hi) * 1.15.
= 4829* IN -LB "1.15
= 5,553.2 IN -LB <== SEE LOAD & DISTRIBUTION SHEET
Mst = J[(LIVE LOAD + DEAD LOAD)*(D/2)] + Tcap*H2
= [3 LEVELS *000 LB/LVL + 10 LB/LVL) * 18 IN/2] + (110 LB
= 16,170.0 IN -LB
Puplift = (Mot - Mst)/D ,
= (5553.2 IN -LB - 16170 IN-LB)/18 IN
0 LB <.= NO UPLIFT
(B) TOP SHELF LOADED
Vtop = 26.6 LB
Vcol= 13.3 LB
Mot= Vtop * h 1.15
=26.6 LB*76 IN 1.15
= 2,326.6 IN -LB
Mst = (LIVE LOAD+DEAD LOAD) * (D/2) -' Tcap*H2 SIDE VIEW
= [100 LB +10 LB] * (18 IN/2) + (110 LB * 120 IN) DEPTH OF UNIT (d) = 18 IN
= 14,190.0 IN -LB TOP SHELF HEIGHT (H1) = 76. IN
# LEVELS= 3.
Puplift = (Mot - Mst)/D CONNECTION HEIGHT (H2) = 120. IN
_ (2326.6 IN -LB - 14190 IN-LB)/18. IN CONN TYPE= 1/4"0 X 3/4"
= 0 LB <= NO UPLIFT Tcap = 110 LB
ANCHORS QUANTITY= 1 PULLOUT = 265 LB SHEAR= 420 LB
(PS/Pt)"5/3 + (VSNt)^5/351.00
COMBINED STRESS(A) = (0 LB/265 LB)^5/3 + (39.9 LB/420 LB)^5/3
= 0.02 < 1.00 OK
COMBINED STRESS(B) = (0 LB/265 LB)^5/3 + (13.3 LB/420 LB)^5/3
= 0.00 < 1.00 OK
USE (1)1/4" Ox2"MIN. EMBED. REDHEAD TRUBOLT (ICC #ER -1372)
OR'APPROVED EQUAL. AT FRONT COLUMN OF STORAGE FIXTURE (1) PER BASE ANGLE.
VALUES ARE THAT WITHOUT SPECIAL INSPECTION.
SPECIAL INSPECTION IS NOT REQUIRED FOR ANCHOR INSTALLATION.
i
A