Loading...
05-0302 (CSCS) Revision 2P.O. BOX 1504 78-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 Application Number: Property Address: APN: Application description Property Zoning: Application valuation: Applicant: r05-00000302 1 79024 HIGHWAY 111 c&-ty/ 4 4 Q" BUILDING & SAFETY DEPARTMENT BUILDING PERMIT 649-820-999- - NEW COMML - STORES & CUSTOMER SERVICE REGIONAL C Architect or Engineer: LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed er provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and P als Code, and my License is in full force and effect. License Class: 572657 License No.: WC 591636301 e: Co ctor: L(/, OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the following reason (Sec. 7031 .5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: 1 _ 1 1, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). (= 1 I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). ' (_ 1 I am exempt under Sec. , B.&P.C. for this reason Date: Owner: CONSTRUCTION LENDING AGENCY _ - I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Name: - Lender's Address: N I LQPERMIT VOICE (760) 777-7012 FAX (760) 777-7011 INSPECTIONS (760) 777-7153 Date: 3/09/07 Owner: --------------------------------- FOURTH QUARTER PROPERTIES 45 ANSLEY DR NEWNAN, GA 30263 D Contractor: MAR 0 9 2007 VRATSINAS CONSTRUCTION O. CITY OFLAQUINTA P.O. BOX 2558 PIS LITTLE ROCK, AR 72203 Lic. No.: WC591636301 WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. V� I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier 0017 Policy Number ZURICH AMERICAN I certify that, in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to beco su 'ect to the workers' compensation laws of California, and agree that, if I should beco j to the workers' compensation provisions of Section 33700 of the Labor Code, I rt ith comply with those provisions. Bate: / icant WARNING: FAILURE TO SECURE WORKERS' CO PENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIE AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the conditions and restrictions set forth on this application. - 1 . Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application, the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents and employees for any act or omission related to the work being . performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above infor ti n ' correct. I agree to comply with all city and county ordinances and state laws relating to building con cti nd hereby authorize representatives of this c ty to�Jenter upon thea ve-mentioned property for ' s purposes. ateGl ( Si ure (Applicant or Agent): Application Number . . . . . 05-00000302 Permit . . . BUILDING PERMIT Additional desc . Permit Fee•.. 1070.00 Plan Check Fee 695.50 Issue Date . . . . 10/28/05 Valuation . . . . 222457 Expiration Date 5/30/07 Qty Unit Charge Per Extension BASE FEE 639.50 123.00 3.5000 ----------------------------------------------------= THOU BLDG 100,001-500,000 ----------------------- 430.50 Permit . . . MECHANICAL Additional desc . Permit Fee 69.00 Plan Check Fee 17.25 Issue Date . . . . 10/28/05 Valuation . . . . 0 Expiration Date 5/30/07 Qty Unit Charge Per Extension BASE FEE 15.00 3.00 9.0000 EA MECH FURNACE <=100K 27.00 3.00 9.0000 ---------------------------------------------------------------------------- EA MECH B/C <=3HP/1OOK BTU 27.00 Permit . . . ELEC-NEW COMMERCIAL Additional desc . Permit Fee 103.92 Plan Check Fee 25.98 Issue Date 10/28/05 Valuation . . . . 0 Expiration Date 5/30/07 Qty Unit Charge Per Extension BASE FEE 15.00 4446.00 .0200 ---------------------------------------------------------------------------- ELEC GARAGE OR NON-RESIDENTIAL 88.92 Permit . . . PLUMBING Additional desc . Permit Fee . . . . 30.00 Plan Check Fee 7.50 Issue Date . . . . 10/28/05 Valuation . . . . 0 - Expiration Date 5/30/07 Qty Unit Charge Per Extension BASE FEE 15.00 2.00 6.0000 EA PLB ROOF DRAIN 12.00 1.00 3.0000 ------------------------------------------------------------------------------ EA PLB WATER INST/ALT/REP 3.00 Permit . . . . . . GRADING PERMIT LQPERMIT LQPERMIT Application Number . . . . . 05-00000302 Permit . . . GRADING PERMIT Additional desc . Permit Fee. . . . . 15.00 Plan Check Fee .00 Issue Date 10/28/05 Valuation 0 Expiration Date 5/30/07 Qty Unit Charge Per Extension BASE FEE 15.00 ----------------------------------------------- ----------------------------- �. Special Notes and Comments 4446 SQ. FT. SHELL BUILDING ONLY (PAD 1).June 10, 2005 2:01:06 PM JJOHNSON AS OF 8-28-06 CHANGE OF CONTRACTOR TO EWING BUILDERS ------------------ --------------------------------------------------------- Other Fees . . . . . . . . . ART IN PUBLIC PLACES -COM 1092.28 CHANGE OF CONTRACTOR 9.00 DIF CIVIC CENTER - COMM 422.37 ENERGY REVIEW FEE 69.55 DIF FIRE PROTECTION -COMM 142.27 HOURLY PLAN CHECK 122.15 STRONG MOTION (SMI) - COM 46.71 DIF STREET MAINT FAC -COMM 102.25 DIF TRANSPORTATION - COMM 7664.90 Fee summary Charged Paid Credited Due Permit Fee Total 1287.92 1287.92 .00 .00 Plan Check Total 746.23 746.23 .00 .00 Other Fee Total 9671.48 9666.98 .00 4'.50 Grand Total 11705.63 11701.13 .00 4.50 THOMAS ENTERPRISES, INC. January 30.,2:007 2385 Shelte-r'l.sland Dri�!F Sm',P 202 San Diego, Olifbrni'a 92106 Tei: 6? 9,2' -619,222.9607 th.orna'sem.corn City of La Quinta .ATtii:.E,d Randall, Building'Departn-wnt 78-495 Calle TainpIc.0 .La QuIluta, CA 92253 'Re*, T Oenter,.Padl Mr., Randall: Thomas Enterprises has clianged contractors .frons Ewing Builders to VCC in order to complete Pad I at The Pavilions at La QUInta. The purpose of this letter is to :transfe.rthe existingboilding permit back to VCC. Th nk..,yOj4 Garrett C 61burn. Development Manager, Thomas Enterprises; lc. CC,,;; RiohDiM VC.C. .Brian. i ng;,. E Rujldo$� -1-S S m u'+i ng,.Arch.'�tecl, .February 9, 2007 Mr. Ed Randall Building & Safety Department City-of.La Quinta. �78-495,Calle Tampico La,oq'iptaq 92253 R e, -Shop;guili- s 46�'646.Adams ,,, 70r,070, Q24, 174; Highway 1'1 '1 DearVir.,'RandaW -Ewing Builders is. no. longer thegeneral contractor for the re -construction of the Iire•damage for Pad 1 at the comerof Adams and Hwy; 111.1 VCC General Contractors,. the original contractor, 'has been assigned to complete te the construction. However, the stamped set of plans- is not being made available to VCC; that LitYs.,approved. and, permitted set of.,cleaWiogs,for the Shops: and tf W -.�. ypsIl ha.'the,, We respep.. u.y�,, j buildings, . - ' 'Pei jh.�Iud -calculations, be sent out for printing, by a. bonded reprographics g ,.,, 11 — - — - - — . phics .ddm.parjq� approved .by- the 'City •6f' La 64u i n t- a. it Is :our u.nderstan n that All Utoy� R6proj.raphics is, .such .a 'bonded company. All printing costs shall be paid by VCC prior to. release of the documents. i Thank you for your cooperation. Respectfully, 1:t:eac) El Camino Real Site z(X) San Diego. CA rprjo FOX EWING February 12, 2007 City of La Quinta Attn: Ed Randall, Building Department 78-495 Calle Tampico La Quinta, CA 92253 - RE: The Pavilion at La Quinta Shopping Center, Pad 1 Mr. Randall: Ewing Builders is no longer the general contractor for the above reference project. Thomas Enterprises has changed contractors from Ewing Builders to VCC. Please transfer the existing building permit back to VCC. Thank You, Brian Ewing -1- THOMAS ENTERPRISES, INC. 1* August 18, 2006 The City of La Quinta 78-495 Calle Tampico La Quinta, CA 92253 (760) 777-7015 La Quinta, CA 92253 RE: Pad 1 Reconstruction To Whom It May Concern: 45 Aisley Drive Newnan, Georgia 30263 Tel: E78.423.5445 Fax: 678.423.5446 wwv,thomasent. om This letter is to notify the city that Ewing Builders _is -responsible for the reconstruction of Pad 1 building, locatetl�at'�793024'Hwy: California, under the previously approved and obtained construction permit Ewing Builders will handle all additional permits, inspections, and new fees, including insurance and business permits. The site work general contractor. VCC ' is still responsible for all flat work, hardscapes and underground utilities for Egad # 1 also under the previously approved and obtained construction permits. � I i Please do..not hesitate to call with any questions or concerns. I { Thanks, } • i I t✓ Kevin Case I s I Thomas Enterprises, Inc. i a _ f� b Sm thConsu tingArch tects July 5, 2006 'Mr. Burt Hanada Building & Safety Manager CITY OF LA QUINTA r Building & Safety Department '78-495 Calle Tampico La Quinta, CA 92253 Re: Pavilion at La Quinta — 7_9�02.4,Highway 1 Building, Reconstruction of Pad Building 1 Dear Mr. Hanada: This letter is in reference to the proposed reconstruction of Pad Building 1, noted above, due to the recent fire that occurred while the building construction was approximately 90% complete. A site visit by Smith Consulting Architects and GSSI structural engineers was performed on May 23, 2006 to assess the extent of the fire and evaluate the structural damage. A copy of the letter from GSSI, that indicates the extent of the structural damage, is attached for reference. Please note that we concur with GSSI's assessment of the extent of the 'damage. Please accept this letter as confirmation that the reconstruction work for this building shall be in accordance with the previously approved plans and specifications under which the building was being constructed.. It is our understanding that these letters are sufficient to allow the reconstruction to start once the demolition work has been completed and inspected by your department. you require ac I•.K--r----- ...., , Barrett, AIA n please let as know at your earliest convenience. Cc: ;Daniel -P.-Crawford,-Jr. - Building Inspector; City of La Quinta w/encl. Mel Kuhnel - Thomas Enterprises w/encl. - - Les VanKuren —VCC w/encl. .1222o EI Camino Real Suite zoo San Diego, CA 92130 858.793.4777 858.793.4787 Fax n, Ala"y-25-2006 02:22pm From-GSSI ENGINEERS 618-687-3814 T-673 P.001/001 F-572 p GSS I Structural Engineers May 25, 2006 Mr. Norman Barrett Project Architect Smith Consulting Architects 12220 El Camino Real, Suite 200 I:-` SAY 2 5 2006 San Diego, CA 92130 Tel: 858-793-4777 �.1ifECrB +v Fax: 858-793-4787 `— Re: The Pavilion at La Quinta — Pad 1 Building Fire Damage Report Dear Mr. Barrett: A site visit was performed on May 23, 2003, to evaluate the structural damage of Pad 1 building due to the fire which occurred this past weekend. Based on our observation the fire damage to the structure occurred in the southeast corner of the building between grids B and D. The fire . damaged the exterior walls, roof mansards, the roof steel deck and the steel trusses fmd biros girders. Except for smoke and soot damage, the 24 inch deep steel truss girder between grids B and C, and the steel tube columns at grids 2-C and 2-D do not appear to have been damaged structurally. In several areas between grids A and B the under side of the steel deck has some smoke and soot damage. The drive-through soffit has visible signs of water damage:. The concrete slab on grade and foundations do not appear to have any damage due to they fire. We recommendation that the walls and roof structure between grids B and D (except for the truss girder between grids B and C, and the columns at grids 2-C and 2-D, be completely removed and rebuilt at as originally should in the construction documents. Also, portions of the roof deck with smoke and soot damage should be thoroughly cleaned or removed and replaced, and Die drive soffit plaster should also be removed and replaced. Additionally, other portions of the building may be required to be removed and replaced subject to further observations; of damaged areas not visible at the time of our site visit. Generally, the remainder of the roof structure between grids A and B appears to be in good condition. Please call if you have any questions. Sincerely, GSSI Engineers Oscar Gonzalez, S.E. Principal