Loading...
06-2658 (RC)P.O. BOX 1504 78-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 Application Number::>,_ 06: 00002658 Property Address: 79255 HIGHWAY 111 STE 2 APN: 649-030-999-8 -30420 - Application description: REMODEL - COMMERCIAL Property Zoning: REGIONAL COMMERCIAL Application valuation: 45000 Tihf 4 4 Q" Applicant: Architect or Engineer: ac-t�' Ilk V BUILDING &{SAFETY DEPARTMENT BUILDING PERMIT -------------------------------------------------- LICENSED CONTRAC 0 DECLARATION I hereby affirm under penalty of perjury at 1 am licensed unde provis ns of Chapter 9 (commencing with Section 7000) of Division 3 of the Busi ess andePo2,onalsode, a d my License is in full force and effect. `Lic�q;eC�s nse 762799 Dai./.�-� Contra—cto�-`,�' 6 OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury hat I am exempt from the Contractor's State License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars (5500).: (_) I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). 1 _ 1 I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects.with a contractor(s) licensed pursuant to the Contractors' State License Law.). ( 1 1 am exempt under Sec. , B.&P.C. for this reason Date: Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). , Lender's Name: Lender's Address: LQPERMEIT Owner: STAMKO DEV CO C/O PROVIDENT FINANCIAL MGMT 10345 W OLYMPIC BLVD 2 FL LOS ANGELES, CA 90064 Contractor: STAMKO DEVELOPMENT CO 6080 CENTER DR, #668 LOS ANGELES, CA 90045 (310)242-5637 Lic. No.: 762799 VOICE (760) 777-7012 FAX (760) 777-7011 INSPECTIONS (760) 777-7153 Date: 9/18/06 ----------------------------------------------- WORKER'S COMPENSATION DECLARATION - I hereby affirm under penalty of perjury one of the following declarations: 1 have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier STATE FUND Policy Number 1557214-2006 I certify that, in the performance of the work for which this permit is issued, I shall not employ any person in, any manner as to become subject to the er ' compensation laws of California,' and.agree that, if I s Id become subj t to the wo ers' c pensation provisions of Section 3700 of the Labor C e, I shall forth th comply !h th a provisions. Date Applicant: t WARNING: FAILURE TO SECURE W RKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMI L PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the conditions and restrictions set forth on this application. 1. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application, the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such pe it, or cessation of work for 180 days will subject permit to cancellation. 1 certify that I have read this application and state that the ab a information is correct. I agre o com y with all city and county ordinances and state laws relating to building struction, and by autho a repre ntatives of this coyg_ty to entjer ugon the above-mentioned property I. spection P. or_ Application Number 06-00002658 Permit . . . BUILDING PERMIT Additional desc . Permit Fee . . . 382.00 Plan Check Fee 248.30 Issue Date . . . . Valuation . . . . 45000 Expiration Date 3/17/07 Qty Unit Charge Per Extension BASE FEE (2.52.00 20.00 6.5000 ---------------------------------------------------------------------------- THOU BLDG 25,001-50,000 i30.00 Permit . . . ELECT -.ADD/ALT/REM Additional desc . Permit Fee . . . . 34.80 Plan Check Fee 8.70 Issue Date . . . . Valuation . . . . 0 Expiration Date . . 3/17/07 Qty Unit Charge Per Extension BASE FEE 15.00 44.00 .4500 ------------------------------------- EA ELEC DEVICE/FIXTURE•>20 --------------------------------------- 19.80 Permit MECHANICAL Additional desc . Permit Fee . . . . 57.50 Plan Check Fee 14.38 Issue Date . . . . Valuation . . . . 0 Expiration Date 3/17/07 Qty Unit Charge Per Extension BASE FEE 15.00 2.00 9.0000 EA MECH FURNACE <=100K 18.00 2.00 9.0000 EA MECH B/C 2=3HP/100K BTU 18.00 1.00 6.5000 ---------------------------------------------------------------------------- EA MECH VENT FAN 6.50 _ Permit . . . PLUMBING •Addit.ional desc . Permit Fee . . . . 52.50 Plan Check Fee 13.13 Issue Date . . . . Valuation . . . . 0 Expiration Date 3/17/07 Qty Unit Charge Per Extension BASE FEE 15.00 2.00 6.0000 EA PLB FIXTURE 12.00 1.00 7.5000 EA PLB WATER HEATER/VENT 7.50 1.00 3.0000 EA PLB WATER INST/ALT/REP 3.00 1.00 15.0000 EA PLB GAS METER 15.00 LQPERDIIT Application Number . . . . . 06-00002658 s - -----------------------------------------------------=---------------------- Special Notes and Comments 1831 sq. ft.TENANT IMPROVEMENT.September 18, 2.006 9:29:10 AM jjohnson Other Fees . . . . . . . . STRONG MOTION (SMI) - COM 9.45 Fee summary Charged --------------------------- Paid -------------------- Credited ---------- Due Permit Fee Total 526.80 00 .00 526.80 Plan Check Total 284.51 .00 .00 284.51 Other Fee Total 9.45 .00 .00 9.45 Grand Total 820.76 .00 .00 820.76 LQPERAIIT y ,Su � r� Ol Al- T .;'4 -r Bin # C2C� t. City of La Quinta Building u Safety Division P.O. Box 1504, 78-495 Calle Tampico La Quinta, CA 92253 - (760) 777-7012 Buildin -mit Application and Tracking Sheet Permitfl 2 O '° Project Address:- -2� y 1) + 2 Owner's Name: A. P. Number: Address:~ Legal Description: City, ST, Zip: • LA dyj*YA CA, 5:7ZZS3 Contractor: Telephone:(7&e>).q'77 "ZPo�6 Address: Project Description: City, ST, Zip: A AvLL 1p pl A Telephone: _ State Lie. # : City Lip. #: Arch., Engr., Designer:g�j N I-& Cr*JiM qT' C�k Address:'Cil a C4 City, ST, Zip: Etk UM Vj4 `UATa_ / Tele hone GJ �j c P '1(� % 5 " l State Lie. #: Name of Contact Person-.- C -A B V�C� Construction Type: Occupancy: Project type (circle one): New Add'n Alter Repair Demo Sq. Ft.: # Stories: # Units: Telephone # of Contact Person: 67&0) 679, a5�Cj Estimated Value of Project: APPLICANT: DO NOT WRITE BELOW THIS LINE # Submittal , Req'd Recd TRACKING PERMIT FEES "Plan Sets Plan Check submit9l G Item Amount Structural Calcs. Reviewed, rea for corrections Plan Check Deposit Truss Calcs. Called Con ct Person Plan Check Balance Energy Calcs. Plans picked up O Construction Flood plain plan ,Plans resubmitted Mechanical Grading, plan 2nd Review, ready r rrection ' sue Electrical " Subcontactor. List Called Contact PersonPlumbing . Grant Deed Plans picked up S.M.I. H.O.A. Approval : Plans resubmitted Grading IN HOUSE: - Review, ready for correctios/issue Developer Impact Fee Planning Approval Called Contact Person .5 A.I.P.P. Pub. Wks. Appr Date of permit' e School Fees C t Fo i 2w c — Pkt c.g -,O>Z " / t -La Nd.X(, Total Permit Fees . Certificate of Occupancy - � uliliw Tea OFBuilding & Safety Department This Certificate is issued pursuant to the requirements of Section 109 of the California Building Code, certifying that, at the time of issuance, this structure was in compliance with the provisions of the Building Code and the various ordinances of the City regulating building construction and/or use. BUILDING ADDRESS: 79-255 HIGHWAY 111 STE #2 Use classification: COMMERCIAL(REVOLUTION RIDE) Occupancy Group: B Owner of Building: STAMKO DEV CO Building Official Type of Construction: VN Building Permit No.: 06-2658 Land Use Zone: CR Address: 10345 OLYMPIC BLVD 2 FL City, ST, ZIP: LOS ANGELES, CA 90064 By: STEVE TRAXEL Date: 02-02-2007 PLACE John R. Hawkins Fire Chief - RIVERSIDE COUNTY FIRE DEPARTMENT In cooperation with the California Department of Forestry and Fire Protection 210 West San Jacinto Avenue • Perris, California 92570 • (909) 940-6900 • Fax (909) 940-6910 I t Proudly serving the January 9, 2007 Unincorporated - - Areas of Riverside ' County and the J33 Enterprises Cities of: 533 S Vinewood Street ` Banning Escondino, CA 92029 Beaumont Re: Sprinkler Monitoring Plan Review LAQ-06-TI-050 Revolution Ride at 79255 Hwy 111 Ste 2, La Quinta Calimesa 4. LAQ-06-TI-092 The Center of La Quinta at 79255 Hwy 111, Ste 4, La Quinta Canyon Lake The alarm plans you submitted for the above referenced project have been reviewed by the Riverside Coachella :• County Fire Department and are approved with the following conditions: Desert Hot Springs 1) NFPA 72, Section 5-2.2.3: It shall be conspicuously indicated by the prime contractor that the fire alarm system providing service at a protected premises complies with all the requirements of this Indian Wells • code by providing a means of third party verification, as specified in 5-2.2.3.1 or. 5-2.2.3.2. Indio 4. 2) For Central Station monitoring service, provide written documentation, at the time of acceptance Lake Elsinore testing, that there is a contract to provide the runner and maintenance services as required • per NFPA 72. La Quinta Moreno Valley 3) 1999 NFPA 72, Sec. 1-5.1.4: Installation personnel shall be supervised by persons who are ;. qualified and experienced in the installation, inspection, and testing of fire alarm systems. Palm Desert Examples of qualified personnel shall include, but not be limited to, the following: a) Factory trained and certified personnel Perris b) National Institute of Certification in Engineering Technologies (NICET) fire alarm level II '' certified personnel Rancho Mirage c) , Personnel licensed or certified by state or local authority San Jacinto ... 4) The Fire Department Planning Division staff shall witness the following inspections/tests: Temecula a) Pre -Device Inspection — Wiring and all junction boxes shall be inspected prior to being covered by wallboards and/or hanging of any devices. b) Acceptance Test - The alarm installer shall provide all needed testing equipment to complete Board of Supervisors the final alarm inspection. Bob Buster, District 1 John Tavaglione, 5) Provide a completed NFPA 72 Record of Completion that the system has been installed in District 2 accordance with the approved plans and specifications as required by 2001 CFC, Sec. 1006.3.4.2. Jim Venable, District 3 Roy Wilson, - .6) The Fire Department Job Card, approved plans and conditions letter must be at the job site or no District 4 inspection will be performed. Marion Ashley, District 5 EMERGENCY SERVICES DIVISION • PLANNING SECTION • INDIO OFFICE 82-675 Highway 111, 2n° FI., Indio, CA 92201 • (760) 863-8886 • Fax (760) 863-7072 \ Requests for inspections are to be made at least 72 hours in advance and may be arranged by calling (760) 863-8886. Should there be need for further information and/or clarification, please contact the undersigned. Thank you for your continuing cooperation in advance. Sincerely, Tracy Hobday Battalion Chief/County Fire Marshal By Sonia Cooley Fire Safety Specialist. t EMERGENCY SERVICES DIVISION • PLANNING SECTION • INDIO OFFICE 82-675 Highway 111, 2nd FI., Indio, CA 92201 • (760) 863-8886 • Fax (760) 863-7072 l 11/1.3/2006 MON 1.0:11 FAX i W�t1UI.ilit) I Bi" Permit # Project Address: City of La Qu'inta �Building U Safety Division U�� j _' P.O. Box 1504, 78-495 Calle Tampico YJ U Quinta, CA 92253•• (760) 777-7012 Building Permit Application and Tracking Sheet �j N � Su1Tfi 2. 0 wncr's Name. �}IUKD vv mPN4� A P. Number Address: 7 2)0&0 ���,E-S1"ftD CJ, Legal Description: Qui " City, ST, Zip: LA, WP tjTp,) (� ZZtJ3 Contractor: "req Telephone (1 D -1 Address: Project Description - .City, ST, Zip: Telephone: State Lie. # :. �O�L Arch., Engr., Designer: City Lie. #: EL Address: Gf A Y__ SATl✓ A C6.. -ST. Zip: ( Telephone: (pQ (p State Lie. #: Name of Contact Person: CA (,� Construction;•iype:v-&V jj CL),T&e ccupancy: Project type {circle one): New Add'n Alter 'Repair Demo l 'i.l�Q . Sq. Ft: �'Gg : #Stories: # Units: j Telephone # of Contact Person: Estimated Value of Project: Z�� ' Uco . APPLICANT: DO NOT WRITE BELOW THIS LINE # Submittal Plaa Sets Req'd. Reed TRACKING .. Plaa Check submitted PERMIT FEES Item Amount Structural Calcs. Reviewed, ready or correetioas Plaa Chetk Deposit T"' G1cs Called Contact Person las Cheek Balance Energy .Ca.Ics. Flood plain plan Plass ticked up Pians resubmitted i>6 Contraction Mechanical Gradiogplao: Sabcoatactor Inst Z"' Review, ready for vi correctlo u e i Called Contact Person Electrical 'Plumbing Grant Deed Plan picked up $.M.I. H.O.A. Approval Plans resubmitted G ding IN IiOUSF:- .".Revlew, ready for torr .onsrtssue Developer Impact Fee,: PlanningApproval Called Contact Person .Pub. Wks. Appr Date of permit issue. School Fees ------------------ ' • ' : ... Total Permit Fees ul 1 �N �aaro(. I RIVERSIDE COUNTY FIRE DEPARTMENT In cooperation with the California Department of Forestry and Fire Protection 210 West Son Jacinto Avenue. Perris, California Fax Tom O'Keefe July 17,2W6 Fire Chief Proudly serving the Gabriel Lujan & Associates Unincorporated 45175 Panorama Drive, Suite A Areas ofd the eside County and Palm Desert, CA 92260 Cities of Banning RE: TENANT IMPROVEMENT PLAN CHECK Beaumont LAQ-06-TI-050/ Revolution Ride at 79255 Hwy 111, Ste 2, La Quinta, CA .• Calimesa You have been issued a release for a tenant improvement on an existing building. THIS IS `' NOT AN OCCUPANCY PERMIT. Canyon Lake Coachella It is prohibited to use/process or store any materials in this occupancy that would classify it o• as an "H" occupancy per Sec. 307 of the 2000 UBC. Desert Hot Springs %% THE FOLLOWING CONDITIONS MUST BE MET PRIOR TO INSPECTION: Indian Wells Indio Install door hardware and exit signs as per Chapter 10 of the 2000 UBC. 441. Lake Elsinore Install Knox Lock Boxes, Models 4400, 3200 or 1300, mounted per recommended standard of the Knox Company. Plans must be submitted to the Fire Department for approval of La4. Quinta C. mounting location/position and operating standards. Special forms are available from this Moreno valley office for the ordering of the Key Lock Boxes. This form must be authorized and signed by o• this office for the correctly coded system to be purchased. If the building/facility is protected Palm Desert with a fire alarm system or burglar alarm system, the lock boxes will require "tamper" `e 0 Perris monitoring. 4. Rancho Mirage A minimum 2A1 OBC Fire Extinguisher, (State Fire Marshal Approved) must be mounted in a c' visible location within 75' walking distance from any point in your building or suite. Fire San Jacinto extinguishers can be installed by a licensed extinguisher company with a State Fire Marshal Temecula service tag attached to the extinguisher, or purchased from a retail store with a sales receipt attached. A licensed fire extinguisher company must service extinguisher yearly. Board of supervisors ELECTRICAL PANEL BOX: Bob Buda, All breakers must be labeled and a clearance of 36 inches must be maintained around the District i panel at all times. John Tava is, District Dtrict 2 OTHER REQUIREMENTS: Jim Venable, Approved building address shall be placed in such a position a to be plainly visible and District3 legible from the street Said numbers shall contrast with their background. Roy Wilson, District4 A durable sign stating "This door to remain unlocked during business hours" shall be placed Marion Ashley, on or adjacent to the front exit door. The sign shall be in letters not less than one inch high District s on a contrasting background. Applicantlinstaller shall be responsible to contact the Fire Department to schedule inspections. A re-inspegff&WM&aa"e W &n.?ggoQgspection is necessary. 82-675 HWwvay 111, 2nd R., Indio, CA 92201 • (760) 863-8985 • Fax (760) 563-7072 Y• , Requests for inspections are to be made at least 72 hours in advance and may be arranged by calling (760) 863-8886. All questions regarding the meaning of these conditions should be referred to the Fire Department Planning & Engineering Staff at (760) 863-8886. Sincerely, Tracy Hobday Chief Fire Department Planner By: Sonia Cooley Fire Safety Specialist TITLE 24 REPORT Title 24 Report for: Stamko Development T. I. ` 79-255 Highway 111, Suite 2 La Quinta, Ca 922 CITY OF LA QUINTA BUILDING & SAFETY DEPT. APPRO ED FOR CONS TR TION Project Design rDAT ` BY Gabriel Lujan and Associates 45-175 Panorama Dr., Suite A Palm Desert, Ca 92260 (760) 568-8545 Report Prepared By: Tim Scott Scott Design & Title 24 77085 Michigan Dr. Palm Desert, CA 92211 (760) 200-4780 Job Number: Date: 7/12/2006 JUL- 12 2006 The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2005 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC - www.energysoft.com. L. EnergyPro 4.1 by EnergySoft Job Number: User Number: 6712 4 PERFORMANCE CERTIFICATE OF COMPLIANCE Part 1 of 3 PERF - PROJECT NAME This Certificate of Compliance lists the building features and performance specifications needed to comply with Title 24, Parts 1 and 6 of the DATE Stamko Development T. 1. DOCUMENTATION AUTHOR 7/12/2006 PROJECT ADDRESS` • Tim Scott '-' — - ---i 79-255 Highway 111, Suite 2 La Quinta The Principal Designer hereby certifys that the proposed building design represented in this set of construction documents is . w PRINCIPAL DESIGNER - ENVELOPE TELEPHONE Building Permit # Gabriel Lujan and Associates (760) 568-8545 ® DOCUMENTATION AUTHOR TELEPHONE Checked by/Date Scott Design & Title 24 (760) 200-4780 Enforcement Agency Use GENERAL INFORMATION This Certificate of Compliance lists the building features and performance specifications needed to comply with Title 24, Parts 1 and 6 of the California Code of Regulations. This certificate applies only to a Building usi g the performance compliance approach. The documentation preparer hereby certifies that the documentation !I. accipate and c plete. DOCUMENTATION AUTHOR DATE OF PLANS DATT • Tim Scott BUILDING CONDITIONED FLOOR AREA 1,813Sq.Ft. The Principal Designer hereby certifys that the proposed building design represented in this set of construction documents is CLIMATE ZONE 15 BUILDING TYPE ® NONRESIDENTIAL HIGH RISE RESIDENTIAL HOTELIMOTEL GUEST ROOM PHASE OF CONSTRUCTION ® NEW CONSTRUCTION ADDITION 5537.2 or 6737.3 to sign this document as the person responsible for its preparation; and that I am a licensed EXISTING + ADDITION/ALTERATION STATEMENT OF COMPLIANCE This Certificate of Compliance lists the building features and performance specifications needed to comply with Title 24, Parts 1 and 6 of the California Code of Regulations. This certificate applies only to a Building usi g the performance compliance approach. The documentation preparer hereby certifies that the documentation !I. accipate and c plete. DOCUMENTATION AUTHOR SI NA DATT • Tim Scott 1-7 I q06 The Principal Designer hereby certifys that the proposed building design represented in this set of construction documents is consistent with the other compliance forms and worksheets, with the specifications, and with any other calculations submitted with this permit application. The proposed building as designed meets the energy efficiency requirements contained in sections 110, 116, through 118, and 140, 142, 143 or 149 of Title 24, Part 6. ENV. LTG. MECH. ❑ ❑ 1. 1 hereby affirm that I am eligible under the provisions of Division 3 of the Business and Professions Code to sign this document as the person responsible for its preparation; and that I am licensed in the State of California as a civil engineer, mechanical engineer, or I am a licensed architect. ❑ ❑ n 2. 1 affirm that I am eligible under the provisions of Division 3 of the Business and Professions Code Section 5537.2 or 6737.3 to sign this document as the person responsible for its preparation; and that I am a licensed contractor performing this work. ❑ ❑ ❑ 3. 1 affirm that I am eligible under Division 3 of the Business and Professions Code to sign this document because it pertains to a structure or type of work described as exempt pursuant to Business and Professions Code Sections 5537, 5538, and 6737.1. (These sections of the Business and Professions Code are printed in full in the Nonresidential Manual.) ENVELOPE COMPLIANCE Indicate location on plans of Note Block for Mandatory Measures Envelope Compliance Not In The Scope Of S Ubmittal Requir orms PRINCIPAL ENVELOPE DESIGNER - NAME SIA LIC. NO. DATE I r<- LIGHTING COMPLIANCE Indicate location on plans of Note Block for Mandatory Measure -1, LTG -2 Required F s PRINCIPAL LIGHTING DESIGNER - NAME SIGNAT RE LIC. NO. DATE Gabriel Luean and Associates • l`�-O MECHANICAL COMPLIANCE Indicate location on plans of Note Block for Mandatory easures MEC -1 MECH-2 MECH-3 MECH-5 Required rms PRINCIPAL MECHANICAL DESIGNER - NAME GN LIC. NO. DAT Scott Design & Title 24 'l7 oro EnergyPro 4.1 by EnergySoft User Number: 6712 Job Number: Page:3 of 23 1 PERFORMANCE CERTIFICATE OF COMPLIANCE Part 2 of 3 PERF -1 PROJECT NAME DATE P' Stamko:DevelOoment:T.l.: 7/12/2006 ANNUAL TDV ENERGY USE SUMMARY kBtu/s ft- r Standard Proposed Compliance ENERGY COMPONENT Design Design Margin ilk S.tanGard' Pranased Space Heating 0:47 0.31 0.16� Space Cooling - 370.89 _ 322.26 48.62 x Indoor Fans . 100.4.5 113.66 -13.21 Heat Rejection o.00 000 o.00 Pumps &'Misc. ''0.00 0.00 0.00 Domestic Hot Water . 56.99 57.48 -0.49 Lighting 16526 192.14. ! -26.88 Receptacle 82.18 82.18 0.00 R mua r Process o.00 . 0.00 o 'ao so so i2o1so1eoz�:o24oz7o��3o3so. TOTALS: `, 776.24768.04„ 8.20 kBtwsgft-yr -" Percent better than Standard: '1.1% ( 1.1% excluding process) BUILDING :COMPLIES GENERAL INFORMATION Building Orientation N o deg Conditioned Floor Area 1,813 sqft. Number of Stories ^1 Unconditioned Floor Area 0 sqft. °Number of.Systems 2 Conditioned Footprint Area 1,813 sqft. Number of Zones 1 Fuel Type Natural Gas Orientation -. Gross Area Glazing Area Glazing Ratio Front Elevation.. N 490 sqft. 170 sqft. 34.7% Left Elevation {E) 728 sqft. 0 sqft. 0.0% Rear Elevation S 490 sqft. 0 sqft. 0.0% Right Elevation (W) 728 sqft., 0 sqft. 0.0O/C Total 2,436 sqft: 170 sqft. 7.0% Roof 1;813 sqft. sqft. O.o% Standard Proposed Lighting Power Density 1.5o6 wisgft.- 1.744 wisgft. Prescriptive.Env.•Heat Loss 40Btuih 403 Btu/h `Prescriptive Env.Heat Gain 34,563 Btu/h-F 35,736 Btu/h-F ,Remarks: i Run Initiation Time: 07/12/06 10:28:10 Run Code: 1152725290 EnergyPro 4.1 by EnergySoft.' User Number: 6712 Job Number: Page:4 of 23 PERFORMANCE CERTIFICATE OF COMPLIANCE Part 3 of 3 PERF -1 PROJECT NAME Stamko Development T.I. DATE 7/12/2006 ZONE INFORMATION if System Name Floor Inst. ' Ctrl. Area LPD Credits Zone Name Occupancy Type (sgft.) (W/sf)l :(W/sf)2 Allowed LPD Proc. Loads (Wlsf) Area Tailored W/s 3 (W/S4 HVAC -1 & 2 Suite 2 Comp Bldg Retail and Wholesale 1,813 1.744 Notes: 1. See LTG -2-C 2. See LTG4-C 3. See LTG -5-C 4. See LTG -6-C Items abova require special documentation (items marked with asterisk, see LTG -2 -C by others) (by others) EXCEPTIONAL CONDITIONS COMPLIANCE CHECKLIST The local enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The local enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted. The HVAC System "Carrier 50JX0605" is designated as 3 Phase, or is Exempted from the NAECA 13 SEER requirement. The exceptional features listed In this performance approach application have specifically been reviewed. Adequate written justification and • documentation for their use have been provided by the applicant. EnergyPro 4.1 by EnergySoft User Number: 6712 Job Number: Page:5 of 23 1 CERTIFICATE OF COMPLIANCE (Part 1 of 3) LTG -1 -C PROJECT NAME DATE Stamko Development T.I. 7/12/2006 INSTALLED INDOOR LIGHTING POWER FOR CONDITIONED AND UNCONDITIONED SPACES INSTALLED LIGHTING, UNCONDITIONED SPACES (From LTG -2-C) 0 LIGHTING CONTROL CREDIT, UNCONDITIONED SPACES (From LTG -4-C) 0 UNCONDITIONED SPACE ADJUSTED INSTALLED LIGHTING POWER 0 ALLOWED INDOOR LIGHTING POWER FOR CONDITIONED SPACES ❑ COMPLETE BUILDING METHOD (From LTG -5-C) ALLOWED ❑ AREA CATEGORY METHOD (From LTG -5-C) WATTS ❑ TAILORED METHOD (From LTG -5-C) ALLOWED LIGHTING POWER 3,162 ❑X PERFORMANCE METHOD ❑ COMMMON LIGHTING SYSTEM (From LTG -8-C) ALLOWED INDOOR LIGHTING POWER FOR UNCONDITIONED SPACES From LTG -5-C o MANDATORY INDOOR AND DAYLIGHTING AUTOMATIC CONTROLS CONTROL LOCATION (Room #) CONTROL IDENTIFICATION CONTROL TYPE Time Switch, Dimming, etc.) Check if SPACE CONTROLLED Daylighting NOTE TO FIELD EnergyPro 4.1 by EnergySoft User Number: 6712 Job Number: Page:6 of 23 1 INSTALLED WATTS INSTALLED LIGHTING, CONDITIONED SPACES (From LTG -2-C) 3,162 PORTABLE LIGHTING (From LTG -3-C) 0 LIGHTING CONTROL CREDIT, CONDITIONED SPACES (From LTG -4-C) 0 CONDITIONED SPACE ADJUSTED INSTALLED LIGHTING POWER 3,162 INSTALLED LIGHTING, UNCONDITIONED SPACES (From LTG -2-C) 0 LIGHTING CONTROL CREDIT, UNCONDITIONED SPACES (From LTG -4-C) 0 UNCONDITIONED SPACE ADJUSTED INSTALLED LIGHTING POWER 0 ALLOWED INDOOR LIGHTING POWER FOR CONDITIONED SPACES ❑ COMPLETE BUILDING METHOD (From LTG -5-C) ALLOWED ❑ AREA CATEGORY METHOD (From LTG -5-C) WATTS ❑ TAILORED METHOD (From LTG -5-C) ALLOWED LIGHTING POWER 3,162 ❑X PERFORMANCE METHOD ❑ COMMMON LIGHTING SYSTEM (From LTG -8-C) ALLOWED INDOOR LIGHTING POWER FOR UNCONDITIONED SPACES From LTG -5-C o MANDATORY INDOOR AND DAYLIGHTING AUTOMATIC CONTROLS CONTROL LOCATION (Room #) CONTROL IDENTIFICATION CONTROL TYPE Time Switch, Dimming, etc.) Check if SPACE CONTROLLED Daylighting NOTE TO FIELD EnergyPro 4.1 by EnergySoft User Number: 6712 Job Number: Page:6 of 23 1 r 17- CERTIFICATE OF COMPLIANCE (Part 3 of 3) LTG -1-C PROJECT NAME Stamko Development T. I. DATE 7/12/2006 Designer: This form is to be used by the designer and attached to the plans. Listed below are all the acceptance tests for lighting systems. The designer is required to check the boxes by all acceptance tests that apply and list all equipment that require an acceptance test. If all equipment of a certain type requires a test, list the equipment description and the number of systems to be tested in parentheses. The NJ number designates the Section in the Appendix of the Nonresidential ACM Manual that describes the test. Also indicate the person responsible for performing the tests (i.e. the installing contractor, design professional or an agent selected by the owner). Since this form will be part of the plans, completion of this section will allow the responsible party, to budget for the scope of work appropriately. Building Departments: Before an occupancy permit is granted for a newly constructed building or space, or a new lighting system system serving a building or space is operated for normal use, all control devices serving the building or space shall be certified as meeting the Acceptance Requirements for Code Compliance. In addition a Certificate of Acceptance, LTG -1-A, Forms shall be submitted to the building department that: A. Certifies plans, specifications, installation certificates, and operating and maintenance information meet the requirements of§ 10-103(b) and Title 24 Part 6. Test Description Test Performed By: ❑ LTG -2-A: Lighting Control Acceptance Document - Occupancy Sensor Acceptance - Manual Daylight Controls Acceptance - Automatic Time Switch Control Acceptance Equipment requiring acceptance testing ❑ LTG -3-A: Automatic Daylighting Controls Acceptance Document Equipment requiring acceptance testing 1 EnergyPro 4.1 by EnergySoft User Number: 6712 Job Number: Paae:7 of 23 1 1� CERTIFICATE OF COMPLIANCE MECH-7-C NAME Stamko Development T. I. DATE 7/1 ueslgner: This form is to be used by the designer and attached to the plans. Listed below are all the acceptance tests for mechanical systems. The designer is required to check the boxes by all acceptance tests that apply and list all equipment that requires an acceptance test. If all equipment of a certain type requires a test, list the equipment description and the number of systems to be tested in parentheses. The NJ number designates the Section in the Appendix of the Nonresidential ACM Manual that describes the test. Also indicate the person responsible for performing the tests (i.e. the installing contractor, design professional or an agent selected by the owner). Since this form will be part of the plans, completion of this section will allow the responsible party to budget for the scope of work appropriately. Building Departments: SYSTEM ACCEPTANCE. Before an occupancy permit is granted for a newly constructed building or space, or a new space -conditioning system serving a building or space is operated for normal use, all control devices serving the building or space shall be certified as meeting the Acceptance Requirements for Code Compliance. In addition a Certificate of Acceptance, MECH-1-A Form shall be submitted to the building department that certifies plans, specifications, installation certificates, and operating and maintenance information meet the requirements of Section 10-103(b) and Title 24 Part 6. STATEMENT OF COMPLIANCE ❑ MECH-2-A: Ventilation System Acceptance Document -Variable Air Volume Systems Outdoor Air Acceptance -Constant Air Volume Systems Outdoor Air Acceptance Equipment requiring acceptance testing Test required on all New systems both New Construction and Retrofit. ❑ MECH-3-A: Packaged HVAC Systems Acceptance Document Equipment requiring acceptance testing Test required on all New systems both New Construction and Retrofit. ❑ MECH-4-A: Air -Side Economizer Acceptance Document Equipment requiring acceptance testing Test required on all New systems both New Construction and Retrofit. Units with economizers that are installed at the factory and certified with the commission do not require equipment testing but do require construction inspection. ❑ MECH-5-A: Air Distribution Acceptance Document Equipment requiring acceptance testing This test required If the unit serves 5,000 ft2 of space or less and 25% or more of the ducts are in nonconditioned or semiconditioned space like an attic. New systems that meet the above requirements. Retrofit systems that meet the above requirements and either extend ducts, replace ducts or replace the packaged unit. ❑ MECH-6-A: Demand Control Ventilation Acceptance Document Equipment requiring acceptance testing All new DCV controls installed on new or existing packaged systems must be tested. ❑ MECH-7-A: Supply Fan Variable Flow Control Acceptance Document Equipment requiring acceptance testing All new VAV fan volume controls installed on new or existing systems must be tested ❑ MECH-8-A:-Hydronic System Control Acceptance Document -Variable Flow Controls Applies to chilled and hot water systems. -Automatic Isolation Controls Applies to new boilers and chillers and the primary pumps are connected to a common header. -Supply Water Temperature Reset Controls Applies to new constant flow chilled and hot water systems that have a design capacity greater than or equal to 500,000 BtWhr. -Water-loop Heat Pump Controls Applies to all new watertoop heat pump systems where the combined loop pumps are greater than 5 hp. -Variable Frequency Controls Applies to all new distribution pumps on new variable Bow chilled, hydronic heat pump or condenser water systems where the pumps motors are greater than 5 hp. Equipment requiring acceptance testing EnergyPro 4.1 by EnergySoft User Number: 6712 Job Number: Page:8 of 23 INDOOR LIGHTING SCHEDULE (Part 1 of 2) LTG -2-C PROJECT NAME DATE Stamko Development T. 1. 7/12/2006 INSTALLED LIGHTING POWER FOR CONDITIONED SPACES • Luminaire Lamps/Ballasts Installed Watts ' C D E F G H I J Name Type Description <m CD� r �•v 3Q).03.m o m m o Q).0 'D N �o°� 3 _� m m oYal i= 3v _ m m v m m N, r C z �'o =S H (2) 4 ft Fluorescent T8 Elec F32T8 2 32 1.0 62.0 X 1 62 (4) 4 ft Fluorescent T8 Elec 4 32 2.0 124.0 X 25 3.100 _ PAGE TOTAL 3 162 BUILDING TOTAL (sum of all pages) 3,162 PORTABLE LIGHTING (From LTG -3-C) D CONTROL CREDIT (From LTG4-C) D • ADJUSTED ACTUAL WATTS 3 162 Kun Initiation I Ime: U711z/Oti 10:zt3:10 Run Gode: 1152725290 EnergyPro 4.1 by EnergySoft User Number: 6712 Job Number: Page:9 of 23 AIR SYSTEM REQUIREMENTS Part 1 of 2 MECH-2-C PROJECT NAME I Stamko Development T. I. ITEM OR SYSTEM TAG(S) Number of Systems T-24 MANDATORY MEASURES Section Heating Equipment Efficiency Cooling Equipment Efficiency Heat Pump Thermostat Furnace Controls Natural Ventilation Minimum Ventilation VAV Minimum Position Control Demand Control Ventilation Time Control Setback and Setup Control Outdoor Damper Control Isolation Zones Pipe Insulation •Duct Insulation PRESCRIPTIVE MEASURES Calculated Heating Capacity x 1.43 2 Proposed Heating Capacity 2 Calculated Sensible Cooling Capacity x 1.212 Proposed Sensible Cooling Capacity 2 Fan Control DP Sensor Location Supply Pressure Reset (DDC only) Simultaneous Heat/Cool Economizer Heating Air Supply Reset Cooling Air Supply Reset Duct Sealing for Prescriptive Compliance 1: For each central and single zone air systems (or group of similar units) fill in the reference to sheet number and/or specification section and paragraph number where the required features are documented. If a requirement is not applicable, put "N/A" in the column. 2: Not required for hydronic heating and cooling. Either enter a value here or put in reference of plans and specificatons per footnote 1. 3: Enter Yes if System is: Constant Volume, Single Zone; Serves < 5,000 sgft; Has > 25% duct in unconditioned space. Duct sealing is required for Prescriptive Compliance, see PERF -1 for performance method duct sealing requirements. DATE 7/12/2006 AIR SYSTEMS, Central or Single Zone HVAC -1 & 2 2 Reference on Plans or Specification 1 112(a) 7.20 HSPF 112(a) 12.0 SEER / 10.2 EER 112(b) Yes 112c,115a n/a 121(b) Yes 121 b) 363 cfm 121 c No 121 c No 121 c 122(e) Programmable Switch 122(e) Heating & Cooling Required 122 Auto 122() n/a 123 124 R-4.2 144 a & b n/a 144 a & b 71,201 btuh 144 a & b n/a 144 a & b 87,398 btuh 144 c Constant Volume 144 c 144 c Yes 144 d No 144 a No Economizer 144 Constant Tem 144(f) Constant Temp 144 k) No AILL-A BsM vm r r -1 -qEALN RL•I Ems! ruU uIAS ua �r•_fu�ua� ii■�Y��� r.f►• EnergyPro 4.1 by EnergySoft User Number: 67112 Job Number: Pape:10 of 23 1 WATER SIDE SYSTEM REQUIREMENTS Part 2 of 2 MECH-2-C PROJECT NAME I Stamko Development T. I. DATE 7/12/2006 2 WATER SIDE SYSTEMS: Chillers, Towers, Boilers, H dronic Loops ITEM OR SYSTEM TAG(S) Number of Systems T-24 MANDATORY MEASURES Section Reference on Plans or Specification' Equipment Efficiency 112(a) Pipe Insulation 123 PRESCRIPTIVE MEASURES Calculated Capacity 144 (a & b) Proposed Capacity 144 (a & b) Tower Fan Controls 144 h Tower Flow Controls 144 h Variable Flow System Design 144 0) Chiller and Boiler Isolation 144 CHW and HHW Reset Controls 144 0) WLHP Isolation Valves 144(l) VSD on CHW, CW & WLHP Pumps > 5 144 ' HP DP Sensor Location 144 0) 1: For each chiller, cooling tower, boiler, and hydronic loop (or groups of similar equipment) fill in the reference to sheet number and/or specification section and paragraph number where the required features are documented. If a requirement is not applicable, put "N/A" in the column. 2: Water side systems include wet side system using other liquids such as glycol or brine. ITEM OR SYSTEM TAG(S) Number of Systems MANDATORY MEASURES Water Heater Certification Water Heater Efficiency Service Water Heating Installation Pool and Spa Efficiency and Control Pool and Spa Installation Pool Heater - No Pilot Light Spa Heater - No Pilot Light 113 (a) 113 b 113 (c) 114 a E b (c) d Service Hot Water, Pool Heating DHW Heater 1 Reference on Plans or Specification' AO SMITH ELJF-10 99% n/a n/a n/a 1: For each water heater, pool heat and domestic water loop (or groups of similar equipment) fill in the reference to sheet number and/or specification section and paragraph number where the required features are documented. If a requirement is not applicable, put "N/A" ins the column. rck-2_rML-A 0IJML".00-1M�1!rrL1.IIUEFrA?rUIUllaIMVEWALWJII� Run Initiation Time: 07/12/06 10:28:10 Run Code: 1152725290 EnergyPro 4.1 by EnergySoft User Number: 6712 Job Number: Page: 11 of 23 U M U W Z O J_ W Q U_ Z 2 W 2 a) 0 O Y ''U VJ M Z Transfer Air N 0 Design Min. Ai m Setpoint J c Max of E! n Columns H, J, a K or 300 CFM Cn 2 c E .Z 2 Bx0.4 m Y CFM/sq. ft. m m a 12 s g 30% of Design t Zone Supply 3 CFM "g Design „ o c m — Vent. Air M f7 o ; CFM H o g REQ -D V.A rn G) = N EX = Max of M c+) H `m g E (D or G) a g y Min CFM m z a E E rn by Occupant o U E E Z m (ExF) �o �0 0 ° `o rn` U CFM = a z o a z LL per o X = E (L Person m D g y E�� v Number of = o m m O uJ People ' d `°m T m E Min CFM � u m 5 = v p by Area m N N (BxC) o s � 0 G Q CFM N o�c .m `o'¢$ a m U per o s E o= E 04 Q Square FootLU n m s a = z C a Conditionco E=Q 9 = m cc Area 2 0 C > U (SF) m 2 Qa m 5 m E ui o` E Z D Q o x yo U m m O m>_ O Q L C m 12O O U'iiY = mm O N J 5 m LL= o e a ~ii 'G Z U) r .E h E _ W W Q fn - m e= - � m m E y a W w> m o a .� J v Q 0 c D D n c c E E E �� `O :.i N N of = ._ c 'x a Z Cd cc .0 mm r � m w 2 z U) _ MECHANICAL EQUIPMENT DETAILS Part 1 of 2 MECH-5-C PROJECT NAME Stamko Development T.I. DATE 7/12/2006 CHILLER AND TOWER SUMMARY Motor Eff. Drive Eff. Efficiency Tons PUMPS Drive Eff. Carrier 50JX0605 Equipment Name Equipment Type Qty. Tot. Qty GPM BHP Motor I Eff. Drive Eff. Pump Control BOILER Energy IStandby TANK INSUL. Rated Vol. Condition Factor Loss or Ext. System Name System Type Distribution Type Qty Input (Gals.) Status or RE Pilot R -Val. O SMITH ELJF-10 Small Elec. Point of Use 1 5,120 10 New 0.95 n/a n/a CENTRAL SYSTEM RATINGS HEATING COOLING Aux. Condition System Name System Type Out ut kW Eff. Out ut Efficient Status Economizer Type Carrier 50JX0605 Packaged DX 2 57,000 0.0 7.20 HSPF 60,000 12.0 SEER / 10.2 JEER New No Economizer 1Rllppl y FAN RFTIIRIJ FAN System Name Fan:[ype Motor Location CFM BHP Motor Eff. Drive Eff. CFM BHP Motor Eff. Drive Eff. Carrier 50JX0605 Constant Volume Draw -Through 2,000 1.00 82.5% 100.0% none EnergyPro 4.1 by EnergySoft User Number: 6712 Job Number: Page: 13 of 23 1 17, ENVELOPE MANDATORY MEASURES ENV -MM PROJECT NAME Stamko Development T.I. DATE 7/12/2006 DESCRIPTION Designer Enforcement §118(a) Installed Insulating Material shall have been certified by the manufacturer to comply with the California Quality Standards for insulating material, Title 20, Chapter 4, Article 3. X❑ § 118(c) All Insulating Materials shall be installed in compliance with the flame spread rating and smoke density requirements of Sections 2602 and 707 of Title 24, Part 2. §117(a) All Exterior Joints and openings in the building that are observable sources of air leakage shall be caulked, gasketed, weatherstripped or otherwise sealed.' ❑ § 116(b) Site Constructed Doors, Windows and Skylights shall be caulked between the unit and the building, and shall be weatherstripped (except for unframed glass doors and fire doors). n§ 116(a)1 Manufactured Doors and Windows Installed shall have air infiltration rates' not exceeding those shown In Table Number 1-E. of the Standards. Manufactured fenestration products must be labeled for U -value according to NFRC procedures. X❑ 1118(e) 118(e) Demising Walls in Nonresidential Buildings: The opaque portions of framed demising walls in nonresidential buildings shall have insulation with an installed R -value of no less than R-11 between framing members. EnergyPro By EnergySoft User Number: User Job Number: Page: 14 of 23 A B C D E F Room Name Task/Activity Description . Room Area (A) M Room Perimeter (P) (ft) Room Cavity Height (H) (ft) Room Cay. Ratio 2.5 x H x P /A EnergyPro 4.1 by EnergySoft User Number: 6712 Job Number: 5 of 23 LIGHTING MANDATORY MEASURES LTG -MM PROJECT NAME Stamko Development T.I. DATE 7/12/2006 DESCRIPTION Designer Enforcement ❑X §131(d)1 For every floor, all interior lighting systems shall be equipped with a separate automatic control to shut off the lighting. This automatic control shall meet the requirements of Section 119 and may be an occupancy sensor, automatic time switch, or other device capable of automatically shutting off the lighting. 4 X❑ §131 (d)2 Override for Building Lighting Shut-off: The automatic building shut-off system is provided with a manual, accessible override switch in sight of the lights. The area of override is not to exceed 5,000 square feet. 0 §119(h) Automatic Control Devices Certified: All automatic control devices specified are certified, all alternate equipment shall be certified and installed as directed by the manufacturer. X❑ §111 Fluorescent Ballast and Luminaires Certified: All fluorescent fixtures specified for the project are certified and listed in the Directory. All installed fixtures shall be certified. §132 Tandem Wiring for One and Three Lamp Fluorescent Fixtures: All one and three lamp fluorescent fixtures are tandem wired with two lamp ballasts where required by Standards Section 132; or all one and three lamp fluorescent fixtures are specified with electronic high -frequency ballasts and are exempt from tandem wiring requirements. §131(a) Individual Room/Area Controls: Each room and area in this building is equipped I with a separate switch or occupancy sensor device for each area with floor -to - ceiling walls. X❑ §131(b) Uniform Reduction for Individual Rooms: All rooms and areas greater than 100 square feet and more than 0.8 watts per square foot of lighting load shall be controlled with bi-level switching for uniform reduction of lighting within the room. §131(c) Daylight Area Control: All rooms with windows and skylights that are greater than 250 square feet and that allow for the effective use of daylight in the area shall have 50% of the lamps in each daylit area controlled by a separate switch; or the effective use of daylight cannot be accomplished because the windows are continuously shaded by a building on the adjacent lot. Diagram of shading during different times of the year is included on plans. ❑ §131(e) Display Lighting. Display lighting shall be separately switched on circuits that are 20 amps or less. EnergyPro 4.1 by EnergySoft User Number: 6712 Job Number: Page: 16 of 23 MECHANICAL MANDATORY MEASURES Part 1 of 2 MECH-MM PROJECT NAME Stamko Development T. I. DATE 7/12/2006 DESCRIPTION Designer Enforcement Equipment and Systems Efficiencies ❑X §111 Any appliance for which there is a California standard established in the Appliance Efficiency Regulations will comply with the applicable standard. ❑ § 115(a) Fan type central furnaces shall not have a pilot light. FX§ 123 Piping, except that conveying fluids at temperatures between 60 and 105 degrees Fahrenheit, or within HVAC equipment, shall be insulated in accordance with Standards Section 123. § 124 Air handling duct systems shall be installed and insulated in compliance with Sections 601, 603 and 604 of the Uniform Mechanical Code. Controls § 122(e) Each space conditioning system shall be installed with one of the following: § 122(e)1A Each space conditioning system serving building types such as offices and manufacturing facilities (and all others not explicitly exempt from the requirements of Section 112 (d)) shall be installed with an automatic time switch with an accessible manual override that allows operation of the system during off -hours for up to 4 hours. The time switch shall be capable of programming different schedules for weekdays and weekends and have program backup capabilities that prevent the loss of the device's program and time setting for at least 10 hours if power is interrupted; or ❑ § 122(e)1 B An occupancy sensor to control the operating period of the system; or F§ 122(e)1 C A 4 -hour timer that can be manually operated to control the operating period of the system. a' 'i122(e)2 Each space conditioning system shall be installed with controls that temporarily restart and temporarily operate the system as required to maintain a setback heating and/or a setup cooling thermostat setpoint. § 122(8) Each space conditioning system serving multiple zones with a combined conditioned floor area more than 25,000 square feet shall be provided with isolation zones. Each zone: shall not exceed 25,000 square feet; shall be provided with isolation devices, such as valves or dampers, that allow the supply of heating or cooling to be setback or shut off independently of other isolation areas; and shall be controlled by a time control device as described above. ® § 122(a&b) Each space conditioning system shall be controlled by an individual thermostat that responds to temperature within the zone. Where used to control heating, the control shall be adjustable down to 55 degrees F or lower. For cooling, the control shall be adjustable up to 85 degrees F or higher. Where used for both heating and cooling, the control shall be capable of providing a deadband of at least 5 degrees F within which the supply of heating and cooling is shut off or reduced to a minimum. X § 122(c) Thermostats shall have numeric setpoints in degrees Fahrenheit (F) and adjustable setpoint stops accessible only to authorized personnel. ❑ § 112(b) Heat pumps shall be installed with controls to prevent electric resistance supplementary heater operation when the heating load can be met by the heat pump alone. EnergyPro By EnergySoft User Number: User Job Number: Page: 17 of 23 MECHANICAL MANDATORY MEASURES Part 2 of 2 MECH-MM PROJECT NAME DATE I Stamko Development T.I. 1 7/12/2006 Description Designer Enforcement Ventilation ❑X § 121(e) Controls shall be provided to allow outside air dampers or devices to be operated at the ventilation rates as specified on these plans. 0 § 122(f) Gravity or automatic dampers interlocked and closed on fan shutdown shall be provided on the outside air intakes and discharges of all space conditioning and exhaust systems. ❑ § 122(o All gravity ventilating systems shall be provided with automatic or readily accessible manually operated dampers in all openings to the outside, except for combustion air openings. k 0 § 121(f)1 Air Balancing: The system shall be balanced in accordance with the National Environmental Balancing Bureau (NEBB) Procedural Standards (1983), or Associated Air Balance Council (AABC) National Standards (1989); or ❑ § 121(02 Outside Air Certification: The system shall provide the minimum outside air as shown on the mechanical drawings, and shall be measured and certified by the Installing licensed C-20 mechanical contractor and certified by (1) the design mechanical engineer, (2) the installing licenced C-20 mechanical contractor, or (3) the person with overall responsibility for the design of the ventilation system; or X] § 121(03 Outside Air Measurement: The system shall be equipped with a calibrated local or remote device capable of measuring the quantity of outside air on a continuous basis and displaying that quantity on a readily accessible display divice; or X❑ §121(04 Another method approved by the Commission. Service Water Heating Systems ❑ § 113(b)2 If a circulating hot water system Is Installed, it shall have a control capable of automatically turning off the circulating pump(s) when hot water is not required. X❑ § 113(b)3B Lavatories In restrooms of public facilities shall be equipped with controls to limit the outlet temperature to 110 degrees F. X] § 113(b)3C Lavatories In restrooms of public facilities shall be equipped with one of the following: Outlet devices that limit the flow of hot water to a maximum of 0.5 gallons per minute. Foot actuated control valves, and outlet devices that limit the flow of hot water to a maximum of 0.75 gallons per minute. Proximity sensor actuated control valves, and outlet devices that limit the flow of hot water to a maximum of 0.75 gallons per minute. Self-closing valves, and outlet devices that limit the flow of hot water to a maximum of 2.5 gallons per minute, and 0.25 gallons/cycle (circulating system). Self-closing valves, and outlet devices that limit the flow of hot water to a maximum of 2.5 gallons per minute, and 0.50 gallons/cycle (non -circulating system). Self-closing valves, and outlet devices that limit the flow of hot water to a maximum of 2.5 gallons per minute, and 0.75 gallons/cycle (foot switches and proximity sensor controls). EnergyPro By EnergySoft User Number: User Job Number: Page: 18 of 23 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME DATE Stamko Development T.I. 7/12/2006 YSTEM NAME FLOOR AREA HVAC -1 & 2 1,813 EATING SYSTEM PSYCHROMETRICS 26.0 of 65.6 of Outside Air 363 cfm 69.6 of Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAK COIL HTG. PEAK CFM I Sensible Latent CFM I Sensible 3,314 55,840 9,41 2,656 33,854 0 2,792 1,693 0 0 363 14,411 5,100 363 16,826 0 0 2,792 1 1,693 75,8341 14,51 54 065 Carrier 50JX0605 87,398 19,097 71,201 Total Adjusted System Output g7 398 19,097 71,201 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK Jul 3 pm Jan 12 am Heating Coil 82.4 of 10-f Supply Fan 4000 cfm 82.4 of —30Supply Air Ducts 82.0 of ROOMS 70.0 of �% Return Air Ducts 4 POOLING SYSTEM PSYCHROMETRICS (Airstream Temperatures at Time of Coolina Peak) I 12.0 / 77.9 of Outside Air 363 cfm 74.7/63.40F 78.0 / 64.9 of 57.5 / 56.5 of 57.5 / 56.5 of e .. Supply Air Ducts Cooling Coil Supply Fan 58.2 / 56.7 of 4000 cfm 55.4% R.H. ROOMS 74.0/63.2OF h Return Air Ducts '4 EnergyPro 4.1 by Energysoft User Number: 6712 Job Number: Page: 19 of 23 ROOM LOAD SUMMARY :1 EnergyPro By EnergySoft User Number: User Job Number: Page:20 of 23 P ROJECT NAME Stamko Development T. I. DATE 7/12/2006 YSTEM NAME HVAC -1 & 2 FLOOR AREA 1,813 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK ZONE NAME ROOM NAME Mult. CFM SENSIBLE LATENT CFM SENSIBLE LATENT CFM SENSIBLE Suite 2 Suite 2 1 3,314 55,840 9,411 3,314 55,840 9,411 2,656 33,854 PAGE TOTAL 1 3,314 55,840 9,411 2,656 33,854 TOTAL 1 3,314 55,840 9,411 2,656 33,854 EnergyPro By EnergySoft User Number: User Job Number: Page:20 of 23 ROOM HEATING PEAK LOADS Project Title Atamkn n,=valnnmant T I Date 7/17/7f111R Room Information Desi n Conditions Room Name Suite 2 Time of Peak Jan 12 am Floor Area 1,813 Outdoor Dry Bulb Temperature 26°F Indoor Dry Bulb Temperature 70°F Btu/hr Conduction Area X X X X x X X X X X X X X X X X X X X X X X X x X X X X X X x X X X X X X x X U -Value X X X x x X X X X X X X X X X X X X X X X X X x X X x X X X X X X X X X X X X AT of = = = = = = = = = = = = = _ = = Btu/hr 1,813.0 0.0340 44 2 712 320.0 0.0740 44 1,042 30.0 0.7200 44 950 60.0 0.7200 44 1,901 30.0 0.7200 44 950 40.0 0.7200 44 1,267 10.0 0.7200 44 317 728.0 0.1100 44 3.524 44 1.527 21.0 0.7000 647 728.0 0.1100 44=1 -1594 perimeter = 174.0 0.7300 44 5,589 Items shown with an asterisk (') denote conduction through an interior surface to another room. Page Total: 23 950 Infiltration: r 1.001 X 1.064 X 1 813 X 14.00 X 0.500 / 6] X � = 9 904 `schedule Air Sensible Area Ceiling Height ACH DT Fraction TOTAL HOURLY HEAT LOSS FOR ROOM 33,854 EnergyPro 4.1 by EnergySoft User Number: 6712 Job Number: Page: 21 of 23 ROOM COOLING PEAK LOADS Project Title Date &L-L- Stamko Development T. I. 7/12/2006 ROOM INFORMATION DESIGN CONDITIONS Room Name Suite 2 Time of Peak Jul 3 pm Floor Area 1,813 Outdoor Dry Bulb Temperature 112 c� Indoor Dry Bulb Temperature 74c� Outdoor Wet Bulb Temperature 78 OF Conduction -30 Roof R.30.2x10.24 -19 Wall .19.2x6.16 Double Metal Tint Double Metal Tint -11 Partition Wall .11.2x4.16 -19 Wall W.19.2x6.16 Metal Door 11 Partition Wall .11.2x4.16 Area 1,813.0 X 320.0 X 120.0 X 50.0 X 728.0 X 469.0 X 21.0 X 728.0 X X 1. Design Equivalent Temperature Difference (DETD) Items shown with an asterisk (') denote conduction through an interior surface to another room. Solar Gain U -Value 0.0340 0.0740 0.7200 0.7200 DETD 1 X X X X X X X X X 72.5 = = = = = = = = = 57.9 27.1 27.1 39.5 42.1 39.1 57.6 30.0 Page Total Orientation Area X X X X X X X X X X SGF X X X X X X X X X X SC Weighting X X X X X X X X X X Factor = = = = = = = = = (N) 30.0 41 0.657 0.832 (N) 60.0 41 0.657 0.832 (N) 30.0 41 0.657 0.832 (N) 40.0 41 0.657 0.832 (N) 10.0 41 0.657 0.832 Page Total Btu/hr 4,468 1,372 2,342 976 3,161 1,461 575 4,611 18 966 Btu/hr 672 1,344 672 896 224 3 808 Sched. Weighting Internal Gain Frac. Area Heat Gain Factor Btu/hr i hts 1.0 X 1,813 X 1.744 Watts/sqft X 3.41 Btuh/Waft X 0.999 = 10,782 ccu ants 1.0c X 1,813 X 300 Btuh/OCC. / 10 sgft/occ. X 1.00 = 5,439 Receptacle 1.0 X 1,813 X 1.340 Wafts/sgft x 3.41 Btuh/Watt X 1.00 = 8,292 rocess 1.0c X 1,813 X 0.000 Wafts/sqft X 3.41 Btuh/Watt X 1.00 = 0 Infiltration: �cheduleX X X X /6]X Air Sensible Area Ceiling Height ACH OT Fraction TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 5570 Sched. Latent Gain Frac. Area Heat Gain Btu/hr Occupants 1.00 X 1 813 X 300 Btuh/OCC. / 100 sgft/occ. = 5 439 Receptacle 1.00 x x 0 000 Wafts/sgft x 1 4131 BtuhlWatt = Process 1.00 X 1,813 X 0.000 Watts/sgft x 1 3.4131 Btuh/Waft = o • Infiltration: x x X13 x x � / 6] x � _ chedule Air Latent Area Ceiling Height ACH pyy TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 9411 EnergyPro By EnergySoft User Number: User Page: 22 of 23 ROOM COOLING COIL LOADS Project Title Date Stamko Development T. 1. 7/12/2006 ROOM INFORMATION DESIGN CONDITIONS Room Name Suite 2 Time of Peak Jul 3 pm Floor Area 1,813 Outdoor Dry Bulb Temperature 112 9F Indoor Dry Bulb Temperature 74`F Outdoor Wet Bulb Temperature 78 `k Conduction -30 Roof R.30.2x10.24 -19 Wall W.19.2x6.16 Double Metal Tint Double Metal Tint -11 Partition Wall W.11.2x4.16 -19 Wall .19.2x6.16 Metal Door -11 Partition Wall .11.2x4.16 Area 1,813.0 X 320.0 X 120.0 X 50.0 X 728.0 X 469.0 X 21.0 X 728.0 X X 1. Design Equivalent Temperature Difference (DETD) Items shown with an asterisk (') denote conduction through an interior surface to another loom. Solar Gain U -Value 1 0.03401 1 0.70001 DETD ' X X X X X X X X X 72.5 = = = = = = = = = 57.9 27.1 27.1 39.5 42.1 39.1 57.6 30.0 Page Total Orientation Area X X X X x x X X x x SGF x X X X X X X X x X SC Weighting x X x X X X X X X X Factor = = = = = = = = (N) 30.0 41 0.657 0.832 (N) 60.0 41 0.657 0.832 (N) 30.0 41 0.657 0.832 (N) 40.0 41 0.657 0.832 _(N) 10.0 41 0.657 0.832 Page Total Btu/hr 4,468 1,372 2,342 976 3,161 1,461 575 4-611 18 966 Btu/hr 672 1,344 672 896 224 3 808 Sched. Weighting Btu/hr Internal Gain Frac. Area Heat Gain Factor i hts 1.0 X 1,813 X 1.744 Watts/sgft X 3.41 BtuhfWatt X 0.999 = 10,782 ccu ants 1.0c X 1,813 X 300 Btuh/OCC. / 10 sgft/occ. x 1.00 = 5,439 Receptacle 1.0 X 1,813 X 1.340 Watts/sgft x 3.41 BtuhfWatt X 1.00 = 8,292 rocess 11.0c X 1,813 X 0.000 Watts/sqft x 3.41 Btuh/Watt X 1.00 = 0 Infiltration: 1.00 X 1.064 X 1 813 X 14.00 X 0.50 /601 X 38 = 8 554 chedule Air Sensible Area Ceiling Height ACH OT Fraction TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 55,840 Sched. Latent Gain Frac. Occupants 1.00 Receptacle 1.00 Process 1.00 Infiltration: ch� Area Heat Gain Btu/hr X 1 813 X 3001 Btuh/OCC. / 100 sgft/occ. = 5 439 x x 0.000 Watts/sgft x 141,41 Btuh/Watt = x 1,813 I x 0.000 Watts/sgft X 3.413 Btuh/watt = I 0I x 7Z1 x L_1,813J x x � / 6 ] x � Air Latent Area Ceiling Height ACH pyy