06-3750 (RC)Co P.O. BOX 1504 78-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 r Application Number: t C06__00003750 _ Property Address: 79255 HIGHWAY -111 STE 4 APN: 649-030-999-8 -30420.- Application description: REMODEL - COMMERCIAL Property Zoning: REGIONAL COMMERCIAL Application valuation: 30000 Tiht 4 4 Quum Architect or Engineer: P1 ------------------ LICENSED CONTRACTOR'S DECLARATION BUILDING & SAFETY DEPARTMENT BUILDING PERMIT I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professionals Cod and my License is in full force and effect. License Class: A Lic N : 762799 DatesContractor: �'W � OWNER -BUILDER DECLARATION �' I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: 1 ) 1, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). (_ ) I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). ( I I am exempt under Sec. , B.&P.C. for this reason Date: Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Name: _ Lender's Address: LQPERAIIT Owner: STAMKO DEV CO C/O PROVIDENT FINANCIAL MGMT 10345 W.OLYMPIC BLVD 2 FL LOS ANGELES, CA 90064 VOICE (760) 777-7012 FAX (760) 777-7011 INSPECTIONS (760) 777-7153 Date: * 11/22/06 Contractor:. U D STAMKO DEVELOPMENT CO 6080 CENTER DR, #668 LOS ANGELES, CA 90045 NOY 28 2006 (310)242-5637 Lic. No.: 762799 PIT%, _ I ----------------------------------------------- WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: _ I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided _for by Section 3700 of the Labor Code, for the performance of the work for which this permit is ' issued. I have and will maintain workers' compensation insurance, as.required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier STATE FUND Policy Number 1557214-2006 I certify that, in the performance of the work for which this permit is issued, I shall not employ any - person in any manner so as to become subject to the workers' compensation laws of California, and agree that, if I should become sub' to the workers' compensation provisions of Section - t�O 3700 of the Labor I hall fort ith omply with those provisions. Date: pplicant:WARNSECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJEMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the conditions and restrictions set forth on this application. 1 . Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application, the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents and employees for any act or omission related to the work being , performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, d ereby authorize representatives of thiscou ty toe ter upon the above-mentioned pr for ' spection urpo s. ate: _d d� $ignat rue(Applicant or Agent): 4w Application Number . . . . 06-00003750 Permit . . . BUILDING PERMIT Additional desc . Permit Fee . . . . 284.50 Plan Check Fee 184.93 Issue Date . . . . Valuation 30000 Expiration Date 5/21/07 . Qty Unit Charge Per Extension BASE FEE 252.00 5.00 6.5000 ----------- -------------------------------------------------------------- THOU BLDG 25,001-50,000 32.50 Permit . . . ELECT - ADD/ALT/REM Additional desc . Permit Fee . . . . 27.60 Plan Check Fee 6.90 Issue Date . . . Valuation . . . . 0 Expiration Date 5/21/07 Qty Unit Charge Per Extension. BASE FEE 15.00 28.00 .4500 ---------------------------------------------=------------------------------ EA ELEC DEVICE/FIXTURE >20 12.60 .Permit . . MECHANICAL Additional desc . Permit Fee 49.00 Plan Check Fee 12.25 Issue Date Valuation 0 Expiration Date 5/21/07 Qty Unit Charge Per Extension BASE FEE 15.00 1.00 11.0000 EA MECH FURNACE >100K 11.00 1.00 16.5000 EA MECH B/C >3-15HP/>100K-500KBTU 16.50 1.00 6.5000 ---------------------------------------------------------------------------- EA MECH VENT FAN 6.50 Permit PLUMBING Additional des.c . Permit Fee 37.50 Plan Check Fee 9.38' Issue Date . . . . Valuation . . 0 Expiration Date -•5/21/07 Qty Unit Charge Per Extension BASE FEE 15.00 2.00 6.0000 EA PLB FIXTURE 12.00 1.00 7.5000.EA ' PLB WATER HEATER/VENT 7.50 1.00 3.0000 EA PLB WATER INST/ALT/REP 3.00 Special Notes and Comments SHELL IMPROVEMENT ONLY.TENANT LQPERAIIT c Application Number . . 06-00003750 --------------------------------------------------------------=------------- Special Notes and Comments IMPROVEMENT PERMIT WILL BE REQUIRED BEFORE TENANT OCCUPIES THIS UNIT. Fee summary Charged Paid Credited Due -------------------------------------------------------- Permit Fee Total 398.60 .00 .00 398.60 Plan Check Total 213.46 .00 .00 213.46 Grand Total 612.06 .00 .00 612.06 • .'Bin If "�}�._�City • of LaQuinta Building& Safety Division P.O. Box 1504, 78-495 Calle Tampico La Quinta, CA 92253 - (760)777-7012 Building Perm'it.Appl i cation. and TrackingSheet Yermit # Project Address: —1cl Owner's Name: A. P. Ntimber Legal Description: Address: 2z -10O City, ST, Zip: LN GjAk Contractor: Telephone. —_Yjj -1CO3P3&4 Project Description: Address: -SVC City, ST, Zip: Telephone: 7)1--71ce8cr. State Lie. # City Lie. Arch., Engr., Address: A* M City, -ST, Zip: yl), ­4A cA,:qjaCc% Telephone: State Lic. #: Name of Contact Person: 6=_r t A Construction Type: 1-4 Occupancy: Project type (circle one): New -Add'n Alter Repair Demo Sq. Ft.: jt�, ;;T# St�ries: A I # Uni ts: Telephone # of Contact Person: r--l"ttimatedValue of Project- APPUCANT: DO NOT WRITE BELOW THIS LINE N Submittal Rqld.: Reed TRACKING PERMIT FEES Plan Sets Plan Check submittedV. 10/ "tto Win Amount Structural Calcs.. Reviewed, ready r corrections Plan Check !Deposit Truss Calcs. Called Contact on �l Hr Plan Check Balance. Energy Calcs. Plans Picked up, Construction Flood plain plan Plans resubmitted II p Mi6chanical Grading, plan 2" Review, ready for correctio /issue'F L -lectrical Subcontactor List. Called Contact Person Plumbing Grant Deed Plans picked up H.O.A. Approval Plans resubmitted Grading IN HOUSE:- Review, ready for correctionstissue Developer Impact . Fe . ei. Planning Approval Called Contact Person A.I.P.P. Pub. Wks. Appr Date Of permit issue School Fees Total Permit, Fees V? John R. Hawkins Fire Chief RIVERSIDE COUNTY FIRE DEPARTMENT In cooperation with the California Department of Forestry and Fire Protection 210 West San Jacinto Avenue • Perris, California 92570. • (909) 940-6900 • Fax (909) 940-6910 fi . Proudly serving the January 9, 2007 Unincorporated Areas of Riverside County and the JJJ Enterprises Cities of: 533 S Vinewood Street Banning Escondino, CA 92029 Beaumont Re: Sprinkler Monitoring Plan Review LAQ-06-TI-050 Revolution Ride at 79255 Hwy 111 Ste 2, La Quinta Calimesa .; LAQ-06-TI-092 The Center of La Quinta at 79255 Hwy 111, Ste 4, La Quinta" Can4. yon Lake The alarm plans you submitted for the above referenced project have been reviewed by the Riverside Coachella County Fire Department and are approved with the following conditions: Desert Hot Springs 1) NFPA 72, Section 5-2.2.3: It shall be conspicuously indicated by the prime contractor that the fire '. alarm system providing service at a protected premises complies with all the requirements of this Indian Wells .; code by providing a .means of third party verification as s pecified in 5-2.2.3.1 or. 5-2.2.3.2. Indio 2) For Central Station monitoring service, provide written documentation, at the time of acceptance Lake Elsinore testing, that there is a contract to provide the runner and maintenance services as required 4 per NFPA 72. La Quinta 4. Mo4. reno valley. 3) 1999 NFPA 72 Sec. 1-5.1.4: Installation personnel shall be supervised b re qualified and experienced in the installation, inspection, and testing of fire alarsm systems Palm Desert Examples of qualified personnel shall include, but not be limited to, the following: e a) Factory trained and certified personnel .Perris b) National Institute of Certification in Engineering Technologies (NICET) fire alarm level II '' certified personnel Rancho Mirage c) Personnel licensed or certified by state or local authority San Jacinto 4. 4) The Fire Department Planning Division staff shall witness the following inspections/tests: Temecula, a) Pre -Device Inspection — Wiring and all junction boxes shall be inspected prior to being covered by wallboards and/or hanging of any devices. b) Acceptance Test - The alarm installer shall provide all needed testing equipment to complete Board of supervisors the final alarm inspection. Bob Buster, ` District 1 John Tavaglione, 5) Provide a completed NFPA 72 Record of Completion that the system has been installed in District 2 accordance with.the approved plans and specifications as required by 2001 CFC, Sec. 1006.3.4.2. Jim Venable, District 3 ; Roy Wilson, 6) The Fire Department Job Card, approved plans and conditions letter must be at the job site or no District 4 inspection will be performed. Marion Ashley, District 5 f EMERGENCY SERVICES DIVISION • PLANNING SECTION . INDIO OFFICE 82-675 Highway 111, 2nd Fl., Indio, CA 92201 • (760) 863-8886 . Fax (760) 863-7072 Requests for inspections are to be made at least 72 hours in advance and may be arranged by calling (760) 863-8886. Should there be need for further information and/or clarification, please contact the undersigned. Thank you for your continuing cooperation in advance. Sincerely, Tracy Hobday Battalion Chief/County Fire Marshal By Sonia Cooley Fire Safety Specialist EMERGENCY SERVICES DIVISION • PLANNING SECTION • INDIO OFFICE 82-675 Highway 111, 2nd FI., Indio, CA 92201 • (760) 863-8886 . Fax (760) 863-7072 06/13/2007 11;27 3102426137 STAMKO PAGE 01 4 t FrOlm JAN GSGCCD 310,242.6197 Ta; CHRIS -RANCH O -W $12=007 erne: 4:02:09 PM Page 1 at t ST K0 DEVELOPMENT 6080 C£N rER Det. x`668 Las ANGZ.LSS, CA 90045 (31.0) 242-5637 e FAcswiLE (310) 242-6137 STAA4KQ1 Q@ACM-CQM March 20, 2007 CITY OF LA QUINTA Building e,nd Safety RE:,_ 79,255 HWY 111, SUITE #4 LA QUINTA, CA 92253 } To Whom it -May Concern; M wilt pin using the above referenced sulte ns Stamko's office for The Centre at La Quints. J for our construction manager, property manager, maintenance personnel and storing the Centre's i-naintenance supplies. If you have any questions, please call me at 310-874-4800. Re ards, C nstine F. Clarke /jlo a- TITLE 24 REPORT 6FACC /COPY Title 24 Report for: Stamko Development T. I. 79-255 Highway 111, Suite 4 La Quinta, Ca 92253 01 Project Designer: r Gabriel Lujan and Associates 45-175 Panorama Dr., Suite A Palm Desert, Ca 92260 (760) 568-8545 Report Prepared By: r Tim Scott Scott Design & Title 24 77085 Michigan Dr. Palm Desert, CA 92211CITY OF LA QUINTA (760) 200-4780 BUILDING & SAFETY DEPT, APP OWED FOR CONS . UCTION r DATED_ Job Number: C�� tioo6 Date: v� 10/19/2006 �y he EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is uthorized by the California Energy Commission for use with both the Residential and Nonresidential 2005 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC - www.energysoft.com. ,�- i EnergyPro 4.2 by EnergySoft Job Number: User Number: 6712 TABLE OF CONTENTS G Cover Page 1 Table of Contents 2 Nonresidential Performance Title 24 Forms 3 Form LTG -7-C Room Cavity Ratio Worksheet 14 Form LTG -MM Lighting Mandatory Measures 15 Form MECH-MM Mechanical Mandatory Measures 16 HVAC System Heating and Cooling Loads Summary 18 Room Load Summary 19 Room Heating Peak Loads 20 Room Cooling Peak Loads 21 Room Cooling Coil Loads 22 . EnergyPro 4.2 by EnergySoft Job Number: User Number 6712 r L PERFORMANCE CERTIFICATE OF COMPLIANCE Part 1 of 3 PERF -1 PROJECT NAME This Certificate of Compliance lists the building features and performance specifications needed to comply with Title 24, Parts 1 and 6 of the DATE Stamko Development T. 1. DOCUMENTATION AUTHOR 10/19/2006 OJECT ADDRESS Tim Scott - 79-255 Highway 111, Suite 4 La Quinta The Principal Designer hereby certifys that the proposed building design represented in this set of construction documents is ZONE CLIMA15 PRINCIPAL DESIGNER - ENVELOPE TELEPHONE Building Permit# Gabriel Lujan and Associates (760) 568-8545 ® DOCUMENTATION AUTHOR TELEPHONE Checked by/Date Scott Design & Title 24 (760) 200-4780 1 Enforcement Agency Use GENERAL INFORMATION This Certificate of Compliance lists the building features and performance specifications needed to comply with Title 24, Parts 1 and 6 of the California Code of Regulations. This certificate applies only to a Building us' g the performance compliance approach. The documentation preparer hereby certifies that the documentation is Acjolutte and Tmplete. DOCUMENTATION AUTHOR DATE OF PLANS Tim Scott BUILDING CONDITIONED FLOOR AREATE 1,155 Sq.Ft. The Principal Designer hereby certifys that the proposed building design represented in this set of construction documents is ZONE CLIMA15 BUILDING TYPE ® NONRESIDENTIAL HIGH RISE RESIDENTIAL HOTEL/MOTEL GUEST ROOM PHASE OF CONSTRUCTION ® NEW CONSTRUCTION ❑ ADDITION 5537.2 or 6737.3 to sign this document as the person responsible for its preparation; and that I am a licensed EXISTING + ADDITION/ALTERATION STATEMENT OF COMPLIANCE This Certificate of Compliance lists the building features and performance specifications needed to comply with Title 24, Parts 1 and 6 of the California Code of Regulations. This certificate applies only to a Building us' g the performance compliance approach. The documentation preparer hereby certifies that the documentation is Acjolutte and Tmplete. DOCUMENTATION AUTHOR SIGNAT EDATE Tim Scott t0 1 I Loll The Principal Designer hereby certifys that the proposed building design represented in this set of construction documents is consistent with the other compliance forms and worksheets, with the specifications, and with any other calculations submitted with this permit application. The proposed building as designed meets the energy efficiency requirements contained in sections 110, 116, through 118, and 140, 142, 143 or 149 of Title 24, Part 6. ENV. LTG. MECH. 1-1 ❑ 1. 1 hereby affirm that I am eligible under the provisions of Division 3 of the Business and Professions Code to sign this document as the person responsible for its preparation; and that I am licensed in the State of California as a civil engineer, mechanical engineer, or I am a licensed architect. ❑ ❑ ❑ 2. 1 affirm that I am eligible under the provisions of Division 3 of the Business and Professions Code Section 5537.2 or 6737.3 to sign this document as the person responsible for its preparation; and that I am a licensed contractor performing this work. F1 ❑ ❑ 3. 1 affirm that I am eligible under Division 3 of the Business and Professions Code to sign this document because it pertains to a structure or type of work described as exempt pursuant to Business and Professions Code Sections 5537, 5538, and 6737.1. (These sections of the Business and Professions Code are printed in full in the Nonresidential Manual.) ENVELOPE COMPLIANCE Indicate location on plans of Note Block for Mandatory Measures Envelope Compliance Not In The Scope Of Su ml a Required.,F s PRINCIPAL ENVELOPE DESIGNER -NAME SIGN UR LIC. NO. DTE !�� LIGHTING COMPLIANCE Indicate location on plans of Note Block for Mandatory a Required Forms LTG - f- 2 PRINCIPAL LIGHTING DESIGNER - NAME SIGNATURE LIC. NO. DATE Gabriel Wan and Associates Q • ,9Co MECHANICAL COMPLIANCE Indicate location on plans of Note Block for Mandatory Measures ECH-1, MECH-2 MECH-3 MECH-5 Required orms PRMECHANICAL DESIGNER - NAME IGN EINCIPAL LIC. NO. DAT Scott Design & Title 24 r0 4D'& EnergyPro 4.2 by EnergySoft User Number: 6712 Job Number: Page: 3 of 22 PERFORMANCE CERTIFICATE OF COMPLIANCE Part 2 of 3 PERF ROJECT NAME DATE Stamko Oevelo merit T. 1. 10/19/2006 ANNUAL TDV ENERGY USE SUMMARY kBtu/s ft- r Standard_ Proposed ENERGY COMPONENT -Design Design Space Heating` 1.e3 o.os - -Space COOling 50313 379.07 Indoor Fans , 72.21 71.64 Heat' Rejection 0.00 0.00 ... Pumps & Misc. 0.00 0.00 Domestic Hot Water 56.79 57.56 Lighting 165.26 147 85 Receptacle 82.18 82.18 Process` 0.00 0.00 TOTALS: 881:40 738.36 Percent better than Standard: .' 16.2% : .' Compliance Margin sqft. sqft. sqft. (Msia lord; 1.77_ s , �� MEM 124:05 0.57 0.00 . 0.00 -0.77 17.41 11 0.00n o.00 Front Elevation 143.04 process) ( 16.2% excluding BUILDING COMPLIES [G`MNE�RALFORMATION ' sqft. Building Orientation' Number of Stories Number of Systems - =Number of Zones,: N 0 d Conditioned Floor Area Unconditioned Floor Area Conditioned Footprint Area Fuel Type .1, 155 sqft. sqft. sqft. 1 o 1 1,155 Natural Gas - _ 1 of 22 Orientation Gross Area Glazing Area Glazing Ratio Front Elevation (N) 240 sqft. 115 sqft. 47.9% ;Left Elevation`_ (E) 624 sqft. 0 sqft. 0.0% Rear Elevation S. 240 sqft. 0 sqft: 0.0% Right, Elevation Total - (w) sea 1,728 sqft sgft. o 115 sqft. sqft. o.o% 6.7% : Roof 1,155 sgft.sgft. 0.0% Standard Proposed Lighting Power Density 1.500 W/sgft. 1.342 W/sgft. ' Prescriptive. Env.. Heat Loss 275 MUM 285 stum Prescriptive Env. Heat Gain 23,407 Btum-F 24,621 Btum-F Remarks: _ Run Initiation Time: 10/19/06 11:27:10 Run Code: 1161282430 EnergyPro 4.2 by EnergySoft ,. -User Number: 6712 Job Number: of 22 PERFORMANCE CERTIFICATE OF COMPLIANCE Part 3 of 3 PERF -1 PROJECT NAME Stamko Development T. I. DATE 10/19/2006 ONE INFORMATION System Name Zone Name Occupancy Type Floor Inst. Ctrl. Area LPD Credits (sgft.) (W/sf)1 (W/sf)2 Allowed LPD Proc. Loads (Wlsf) Area Tailored W/s 3 W/s 4 HVAC -1 Suite 4 Comp Bldg Retail and Wholesale 1,155 1.34 Notes: 1. See LTG -2-C 2. See LTG -4-C 3. See LTG -5-C 4. See LTG -6-C Items above require special documentation (items marked with asterisk, see LTG -2 -C by others) (by others) EXCEPTIONAL CONDITIONS COMPLIANCE CHECKLIST The local enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The local enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted. The HVAC System "Carrier 50JX0605' is designated as 3 Phase, or is Exempted from the NAECA 13 SEER requirement. The exceptional features listed in this performance approach application have specifically been reviewed. Adequate written justification and Ou"thorized cumentation for their use have been provided by the applicant. Signature or Stamo EnergyPro 4.2 by EnergySoft User Number: 6712 Job Number: Page:5 of 22 1 CERTIFICATE OF COMPLIANCE (Part 1 of 3) LTG -1 -C NAME Stamko Development T. I. DATE 10/19/2006 INSTALLED LIGHTING, UNCONDITIONED SPACES (From LTG -2-C) 0 LIGHTING CONTROL CREDIT, UNCONDITIONED SPACES (From LTG -4-C) 0 UNCONDITIONED SPACE ADJUSTED INSTALLED LIGHTING POWER 0 ALLOWED INDOOR LIGHTING POWER FOR CONDITIONED SPACES ❑ COMPLETE BUILDING METHOD (From LTG -5-C) ALLOWED ❑ AREA CATEGORY METHOD (From LTG -5-C) WATTS ❑ TAILORED METHOD (From LTG -5-C) ALLOWED LIGHTING POWER 1 550 PERFORMANCE METHOD ❑ COMMMON LIGHTING SYSTEM (From LTG -8-C) ALLOWED INDOOR LIGHTING POWER FOR UNCONDITIONED SPACES From LTG -5-C) o MANDATORY INDOOR AND DAYLIGHTING AUTOMATIC CONTROLS CONTROL LOCATION (Room #) INSTALLED CONTROL TYPE (Auto Time Switch, Dimming, etc.) WATTS Check if Dayiighting NOTE TO' FIELD INSTALLED LIGHTING, CONDITIONED SPACES (From LTG -2-C) 1,550 PORTABLE LIGHTING (From LTG -3-C) 0 LIGHTING CONTROL CREDIT, CONDITIONED SPACES (From LTG -4-C) 0 CONDITIONED SPACE ADJUSTED INSTALLED LIGHTING POWER 1,550 INSTALLED LIGHTING, UNCONDITIONED SPACES (From LTG -2-C) 0 LIGHTING CONTROL CREDIT, UNCONDITIONED SPACES (From LTG -4-C) 0 UNCONDITIONED SPACE ADJUSTED INSTALLED LIGHTING POWER 0 ALLOWED INDOOR LIGHTING POWER FOR CONDITIONED SPACES ❑ COMPLETE BUILDING METHOD (From LTG -5-C) ALLOWED ❑ AREA CATEGORY METHOD (From LTG -5-C) WATTS ❑ TAILORED METHOD (From LTG -5-C) ALLOWED LIGHTING POWER 1 550 PERFORMANCE METHOD ❑ COMMMON LIGHTING SYSTEM (From LTG -8-C) ALLOWED INDOOR LIGHTING POWER FOR UNCONDITIONED SPACES From LTG -5-C) o MANDATORY INDOOR AND DAYLIGHTING AUTOMATIC CONTROLS CONTROL LOCATION (Room #) CONTROL IDENTIFICATION CONTROL TYPE (Auto Time Switch, Dimming, etc.) SPACE CONTROLLED Check if Dayiighting NOTE TO' FIELD i I EnergyPro 4.2 by EnergySoft User Number: 6712 Job Number: Page:6 of 22 1 4 CERTIFICATE OF COMPLIANCE (Part 3 of 3) LTG-1-C. PROJECT NAME Stamko Development T. 1. DATE 10/19/2006 esigner: This form is to be used by the designer and attached to the plans. Listed below are all the acceptance tests for lighting systems. The designer is required to check the boxes by all acceptance tests that apply and list all equipment that require an acceptance test. If all equipment of a certain type requires a test, list the equipment description and the number of systems to be tested in parentheses. The NJ number designates the Section in the Appendix of-the Nonresidential ACM Manual that describes the test. Also indicate the person responsible for performing the tests (i.e. the installing contractor, design professional or an agent selected by the owner). Since this form will be part of the plans, completion of this section will allow the responsible party to budget for the scope of work appropriately. Building Departments: Before an occupancy permit is granted for a newly constructed building or space, or a new lighting system system serving a building or space is operated for normal use, all control devices serving the building or space shall be certified as meeting the Acceptance Requirements for Code Compliance. In addition a Certificate of Acceptance, LTG-1-A, Forms shall be submitted to the building department that: A. Certifies plans, specifications, installation certificates, and operating and maintenance information meet the requirements of§ 10-103(b) and Title 24 Part 6. Test Description Test Performed By: ❑ LTG-2-A: Lighting Control Acceptance Document - Occupancy Sensor Acceptance - Manual Daylight Controls Acceptance - Automatic Time Switch Control Acceptance Equipment requiring acceptance testing ❑ LTG-3-A: Automatic Daylighting Controls Acceptance Document Equipment requiring acceptance testing EnergyPro 4.2 by EnergySoft User Number: 6712 Job Number: Page:7 of 22 4 4 CERTIFICATE OF COMPLIANCE MECH-1-C PROJECT NAME DATE 1h Stamko Development T.I. 10/19/2006 Designer: This form is to be used by the designer and attached to the plans. Listed below are all the acceptance tests for mechanical systems. The designer is required to check the boxes by all acceptance tests that apply and list all equipment that requires an acceptance test. If all equipment of a certain type requires a test, list the equipment description and the number of systems to be tested in parentheses. The NJ number designates the Section in the Appendix of the Nonresidential ACM Manual that describes the test. Also indicate the person responsible for performing the tests (i.e. the installing contractor, design professional or an agent selected by the owner). Since this form will be part of the plans, completion of this section will allow the responsible party to budget for the scope of work appropriately. Building Departments: SYSTEM ACCEPTANCE. Before an occupancy permit is granted for a newly constructed building or space, or a new space -conditioning system serving a building or space is operated for normal use, all control devices serving the building or space shall be certified as meeting the Acceptance Requirements for Code Compliance. In addition a Certificate of Acceptance, MECH-1-A Form shall be submitted to the building department that certifies plans, specifications, installation certificates, and operatinq and maintenance information meet the requirements of Section 10-103(61 and Title 24 Part R STATEMENT OF COMPLIANCE ❑ MECH-2-A: Ventilation System Acceptance Document -Variable Air Volume Systems Outdoor Air Acceptance -Constant Air Volume Systems Outdoor Air Acceptance Equipment requiring acceptance testing Test required on all New systems both New Construction and Retrofit. ❑ MECH-3-A: Packaged HVAC Systems Acceptance Document Equipment requiring acceptance testing Test required on all New systems both New Construction and Retrofit. MECH-4-A: Air -Side Economizer Acceptance Document Equipment requiring acceptance testing Test required on all New systems both New Construction and Retrofit. Units with economizers that are installed at the factory and certified with the commission do not require equipment testing but do require construction inspection. ❑ MECH-5-A: Air Distribution Acceptance Document Equipment requiring acceptance testing This test required If the unit serves 5,000 R2 of space or less and 25% or more of the ducts are in nonconditioned or semiconditioned space like an attic. New systems that meet the above requirements. Retrofit systems that meet the above requirements and either extend ducts, replace ducts or replace the packaged unit. ❑ MECH-6-A: Demand Control Ventilation Acceptance Document Equipment requiring acceptance testing + All new DCV controls installed on new or existing packaged systems must be tested. ❑ MECH-7-A: Supply Fan Variable Flow Control Acceptance Document Equipment requiring acceptance testing All new VA fan volume controls installed on new or existing systems must be tested ❑ MECH-8-A:-Hydronic System Control Acceptance Document -Variable Flow Controls Applies to chilled and hot water systems. -Automatic Isolation Controls Applies to new boilers and chillers and the primary pumps are connected to a common header. -Supply Water Temperature Reset Controls Applies to new constant flow chilled and hot water systems that have a design capacity greater than or equal to 500,000 Btulhr. -Water-loop Heat Pump Controls Applies to all new watedoop heat pump systems where the combined loop pumps are greater than 5 hp. -Variable Frequency Controls Applies to all new distribution pumps on new variable flow chilled, hydronic heat pump or condenser water systems where the pumps motors are greater than 5 hp. Equipment requiring acceptance testing EnergyPro 4.2 by EnergySoft User Number: 6712 Job Number: Page:8 of 22 INDOOR LIGHTING SCHEDULE (Part 1 of 2) LTG -2-C ECT NAME Stamko Development T. I. ITIONED DATE 10/19/2006 Luminaire Lamps/Ballasts Installed Watts C D E F G H I J Name Type Description �m ca'c 3 3 3 N m `� ° r 3mo N cmc 3.av 3 o� SR m `, ° r- 3� vm N m 0 m n mm C C) �' Yes No r C Z 3• �or Lu y xm3 - N al n (2) 4 ft Fluorescent T8 Elec F32T8 2 32 1.0 62.0 X 1 62 (4) 4 ft Fluorescent T8 Elec 4 32 2.0 124.0 X 12 1.488 PAGE TOTAL 1 550 BUILDING TOTAL (sum of all pages) 1 ,550 PORTABLE LIGHTING (From LTG -3-C) CONTROL CREDIT (From LTG -4-C) D • ADJUSTED ACTUAL WATTS 1 550 EnergyPro 4.2 by EnergySoft User Number: 6712 Job Number: Paae:9 of 22 1 AIR SYSTEM REQUIREMENTS Part 1 of 2 MECH-2-C ROJECT NAME 1 Stamko Development T.I. ITEM OR SYSTEM TAG(S) Number of Systems T-24 MANDATORY MEASURES Section Heating Equipment Efficiency Cooling Equipment Efficiency Heat Pump Thermostat Furnace Controls Natural Ventilation Minimum Ventilation VAV Minimum Position Control Demand Control Ventilation Time Control Setback and Setup Control Outdoor Damper Control Isolation Zones Pipe Insulation Wct Insulation PRESCRIPTIVE MEASURES Calculated Heating Capacity x 1.43 2 Proposed Heating Capacity 2 Calculated Sensible Cooling Capacity x 1.212 Proposed Sensible Cooling Capacity 2 Fan Control DP Sensor Location Supply Pressure Reset (DDC only) Simultaneous HeatlCool Economizer Heating Air Supply Reset Cooling Air Supply Reset Duct Sealing for Prescriptive Compliance DATE 10/19/2006 AIR SYSTEMS, Central or Single Zone HVAC -1 1 Reference on Plans or Specification 1 112(a) 7.20 HSPF 112(a) 12.0 SEER / 10.2 EER 112(b) Yes 112(c), 115(a) n/a 121(b) Yes 121 b 231 cfm 121 c No 121(c) No 121 c 122(e) Programmable Switch 122(e) Heating & Cooling Required 122 Auto 122( n/a 123 124 R-4.2 144 a & b n/a 144 a&b 0btuh 144 a & b n/a 144 a & b 37,872 btuh 144 c Constant Volume 144 c) 144 c Yes 144 d No 144 a No Economizer 144 Constant Tem 144 (f) Constant Temp 144 k No 1: For each central and single zone air systems (or group of similar units) fill in the reference to sheet number and/or specification section and paragraph number where the required features are documented. If a requirement is not applicable, put "N/A" in the column. 2: Not required for hydronic heating and cooling. Either enter a value here or put in reference of plans and specificatons per footnote 1. 3: Enter Yes if System is: Constant Volume, Single Zone; Serves < 5,000 sgft; Has > 25% duct in unconditioned space. Duct sealing is required for Prescriptive Compliance, see PERF -1 for performance method duct sealing requirements. 1w I U-0 I V f ICLU - r - r MUIIUIIIU LJULJdFL111e111L use vm L_ EnergyPro 4.2 by EnergySoft User Number: 6712 Job Number: Paae:10 of 22 1 WATER SIDE SYSTEM REQUIREMENTS Part 2 of 2 MECH-2-C ROJECT NAME DATE I Stamko Development T. 1. 10/19/2006 2 WATER SIDE SYSTEMS: Chillers, Towers, Boilers, H dronic Loops ITEM OR SYSTEM TAG(S) Number of Systems T-24 MANDATORY MEASURES Section Reference on Plans or Specification Equipment Efficiency 112(a) Pipe Insulation 123 PRESCRIPTIVE MEASURES Calculated Capacity 144 (a & b) Proposed Capacity 144 (a & b) Tower Fan Controls 144 h Tower Flow Controls 144 h Variable Flow System Design 144 0) Chiller and Boiler Isolation 144 CHW and HHW Reset Controls 144 0) WLHP Isolation Valves 144 ' VSD on CHW, CW & WLHP Pumps > 5 144 0) HP DP Sensor Location 144 0) •1: For each chiller, cooling tower, boiler, and hydronic loop (or groups of similar equipment) fill in the reference to sheet number and/or specification section and paragraph number where the required features are documented. If a requirement is not applicable, put "N/A" in the column. 2: Water side systems include wet side system using other liquids such as glycol or brine. ITEM OR SYSTEM TAG(S) Number of Systems MANDATORY MEASURES Water Heater Certification 113 (a) Water Heater Efficiency 113 b Service Water Heating Installation 113 (c) Pool and Spa Efficiency and Control 114 a) Pool and Spa Installation 114 (b Pool Heater - No Pilot Light 115 (c) Spa Heater - No Pilot Light 115 d Service Hot Water, Pool Heating DHW Heater 1 Reference on Plans or Specification' AO SMITH ELJF-06' 99% n/a n/a n/a 1: For each water heater, pool heat and domestic water loop (or groups of similar equipment) fill in the reference to sheet number and/or specification section and paragraph number where the required features are documented. If a requirement is not applicable, put "N/A" ins the column. I L%J 1 y r1GLl./ - rVl 10ununlm LJVU011aiminyzm! will Run Initiation Time: 10/19/0611:27:10 Run Code: 1161282430 EnergyPro 4.2 by EnergySoft User Number: 6712 Job Number: Page: 11 of 22 U M V W Z O r Q J_ F— W U_ LU Z U5 I N O W a O rn N Z Transfer Air N N 0 Design Min. Ail _ 04 a Setpoint Max of J Columns H, J, m 6 M K or 300 CFM a E 5 Bx0.4 .z N j O Q Y CFM/sq. ft. m d Q m g 30% of Design L Zone Supply 3 CFM d Design M M m h o o m m — Vent. Air (14 `" E 3 CFM o g REQ'D V.A Lr) L N E x = Max of N N y m g E a S Min CFM m m`a a E g a N C7 by Occupant o H U E E Z Q (Ex F) V �—m' a m ��, o 0 V a z o Q Q CFM Z per U o W w x m Qa Person m a m s E c m m N E G v W Number of t _ c m o o � O People m m m `m o E m o m Min CFM LO p by Area N H = mCIj w (BxC) s o� n N 47 mU CFM N o Z m` E per o E�� E N Square Foot `m > o o < :3m w n m 9 _ c z Lo E E m= o v a Condition m D D w. m Area a V m C o m V (SF) d x m F o ami m Z o Q o y o U m m y2 Q J m w, m N 0 -i m o 2 V L > 0 U) `o LL x a �$ F W a c E c m a`) Z E 5 n tL i v m `m o m Q N m 10 'n m m U E 'v J x m o m n _ m t� Q`m O v D 42 c E_ N •• .- c x uEi c a m K O Q 2 U 2 IL- ami a`- r- W 2 2 Z MECHANICAL EQUIPMENT DETAILS Part 1 of 2 MECH-5-C PROJECT NAME Stamko Development T. 1. TIATE0/119/2006 ILLER AND TOWER SUMMARY System Name System Type Efficiency Tons PUMPS Vol. (Gals.) Condition Status Equipment Name Equipment Type Qty. Tot. Qty GPM BHP Motor Eff. Drive Eff. Pump Control 0.95 n/a n/a MULTI -FAMILY CENTRAL WATER HEATING DETAILS Hot Water P mp Hot Water Piping Len th ft Control # HP Type In Plenum Outside DHW / BOILER SUMMARY Add 1/2" Insulation Energy Factor or RE Standby Loss or Pilot TANK INSUL. System Name System Type Distribution Type Qty Rated Input. Vol. (Gals.) Condition Status Ext. R -Val. O SMITH ELJF-06* Small Elec. Point of Use 1 5,120 6 New 0.95 n/a n/a MULTI -FAMILY CENTRAL WATER HEATING DETAILS Hot Water P mp Hot Water Piping Len th ft Control # HP Type In Plenum Outside Buried Add 1/2" Insulation ENTRAL SYSTEM RATINGS HEATING COOLING System Name S stem Type QW Output Aux. kW Eff. Outout Efficiency Condition Status Economizer Type Carrier 50JX0605 Packaged DX 1 0 0.0 7.20 HSPF 60,000 12.0 SEER / 10.2 EER New No Economizer CENTRAL SYSTEM FAN SUMMARY N System Name Fan T e Motor Location CFM BHP Motor Eff. Drive Eff. CFM BHP Motor Eff. Drive Eff. Carrier 50JX0605 Constant Volume Draw -Through 2,000 0.75 77.0% 100.0% none Run Initiation Time: 10/19/0611:27:10 Run Code: 1161282430 EnergyPro 4.2 by Energysoft User Number: 6712 Job Number: Page: 13 of 22 A B C D E F Room Name Task/Activity Description Room Area (A) (so Room Perimeter (P) (ft) Room Cavity Height (H) (ft) Room Cay. Ratio 2.5 x H x P /A EnergyPro 4.2 by EnergySoft User Number: 6712 Job Number: Page: 14 of 22 4 4 LIGHTING MANDATORY MEASURES LTG -MM ECT NAME Stamko Development T. I. DATE 10/19/2006 DESCRIPTION Designer Enforcement §131(d)1 For every floor, all interior lighting systems shall be equipped with a separate automatic control to shut off the lighting. This automatic control shall meet the requirements of Section 119 and may be an occupancy sensor, automatic time switch, or other device capable of automatically shutting off the lighting. a §131(d)20verride for Building Lighting Shut-off: The automatic building shut-off system is provided with a manual, accessible override switch in sight of the lights. The area of override is not to exceed 5,000 square feet. X] §119(h) Automatic Control Devices Certified: All automatic control devices specified are certified, all alternate equipment shall be certified and installed as directed by the - manufacturer. XI §111 Fluorescent Ballast and Luminaires Certified: All fluorescent fixtures specified for the project are certified and listed in the Directory. All installed fixtures shall be certified. X] §132 Tandem Wiring for One and Three Lamp Fluorescent Fixtures: All one and three lamp fluorescent fixtures are tandem wired with two lamp ballasts where required - by Standards Section 132; or all one and three lamp fluorescent fixtures are specified with electronic high -frequency ballasts and are exempt from tandem wiring requirements. , RI §131(a) Individual Room/Area Controls: Each room and area in this building is equipped with a separate switch or occupancy sensor device for each area with floor -to - ceiling walls. §131(b) Uniform Reduction for Individual Rooms: All rooms and areas greater than 100 square feet and more than 0.8 watts per square foot of lighting load shall be controlled with bi-level switching for uniform reduction of lighting within the room. ❑ §131(c) Daylight Area Control: All rooms with windows and skylights that are greater than 250 square feet and that allow for the effective use of daylight in the area shall have 50% of the lamps in each daylit area controlled by a separate switch; or the effective use of daylight cannot be accomplished because the windows are continuously shaded by a building on the adjacent lot. 'Diagram of shading during different times of the year is included on plans. ❑. §131(e) Display Lighting. Display lighting shall be separately switched on circuits that are 20 amps or less. EnergyPro 4.2 by EnergySoft User Number: 6712 Job Number: Page: 15 of 22 4 4 MECHANICAL MANDATORY MEASURES Part 1 of 2 MECH-MM ECT NAME Stamko Development T.I. DATE 10/19/2006 DESCRIPTION Designer Enforcement Equipment and Systems Efficiencies §111 Any appliance for which there is a California standard established in the Appliance Efficiency Regulations will comply with the applicable standard. F] § 115(a) Fan type central furnaces shall not have a pilot light. § 123 Piping, except that conveying fluids at temperatures between 60 and 105 degrees Fahrenheit, or within HVAC equipment, shall be insulated in accordance with Standards Section 123. RX § 124 Air handling duct systems shall be installed and insulated in compliance with Sections 601, 602, 603, 604, and 605 of the 2001 CMC Standards. Controls § 122(e) Each space conditioning system shall be installed with one of the following: FX] § 122(e)1A Each space conditioning system serving building types such as offices and manufacturing facilities (and all others not explicitly exempt from the requirements of Section 112 (d)) shall be installed with an automatic time switch with an • accessible manual override that allows operation of the system during off -hours for up to 4 hours. The time switch shall be capable of programming different schedules for weekdays and weekends and have program backup capabilities that prevent the loss of the device's program and time setting for at least 10 hours if power is interrupted; or § 122(e)1 B An occupancy sensor to control the operating period of the system; or § 122(e)1 C A 4 -hour timer that can be manually operated to control the operating period of the system. X❑ § 122(e)2 Each space conditioning system shall be installed with controls that temporarily restart and temporarily operate the system as required to maintain a setback heating and/or a setup cooling thermostat setpoint. F§ 122(8) Each space conditioning system serving multiple zones with a combined conditioned floor area more than 25,000 square feet shall be provided with isolation zones. Each zone: shall not exceed 25,000 square feet; shall be provided with isolation devices, such as valves or dampers, that allow the supply of heating or cooling to be setback or shut off independently of other isolation areas; and shall be controlled by a time control device as described above. ® § 122(a&b) Each space conditioning system shall be controlled by an individual thermostat that responds to temperature within the zone. Where used to control heating, the control shall be adjustable down to 55 degrees F or lower. For cooling, the control shall be adjustable up to 85 degrees F or higher. Where used for both heating and cooling, the control shall be capable of providing a deadband of at least 5 degrees F within which the supply of heating and cooling is shut off or reduced to a minimum. RX § 122(c) Thermostats shall have numeric setpoints in degrees Fahrenheit (F) and adjustable setpoint stops accessible only to authorized personnel. § 112(b) Heat pumps shall be installed with controls to prevent electric resistance supplementary heater operation when the heating load can be met by the heat pump alone. + EnergyPro By EnergySoft User Number: User Job Number: Page: 16 of 22 F— L L MECHANICAL MANDATORY MEASURES Part 2 of 2 MECH-MM ECT NAME Stamko Development T.I. DATE 10/19/2006 Description Designer Enforcement Ventilation r§ 121(e) Controls shall be provided to allow outside air dampers or devices to be operated at the ventilation rates as specified on these plans. X] § 122(f) Gravity or automatic dampers interlocked and closed on fan shutdown shall be provided on the outside air intakes and discharges of all space conditioning and exhaust systems. § 122(o All gravity ventilating systems shall be provided with automatic or readily accessible manually operated dampers in all openings to the outside, except for combustion air openings. X❑ § 121 (01 Air Balancing: The system shall be balanced in accordance with the National Environmental Balancing Bureau (NEBB) Procedural Standards (1983), or Associated Air Balance Council (AABC) National Standards (1989); or ❑ § 121(02 Outside Air Certification: The system shall provide the minimum outside air as shown on the mechanical drawings, and shall be measured and certified by the Installing licensed C-20 mechanical contractor and certified by (1) the design mechanical engineer, (2) the installing licenced C-20 mechanical contractor, or (3) the person with overall responsibility for the design of the ventilation system; or X] § 121(03 Outside Air Measurement: The system shall be equipped with a calibrated local or remote device capable of measuring the quantity of outside air on a continuous basis and displaying that quantity on a readily accessible display divice; or X § 121(f)4 • Another method approved by the Commission. Service Water Heating Systems F1§ 113(b)2 If a circulating hot water system is installed, it shall have a control capable of automatically turning off the circulating pump(s) when hot water is not required. X] § 113(c) Lavatories in restrooms of public facilities shall be equipped with controls to limit the outlet temperature to 110 degrees F. EnergyPro By EnergySoft User Number: User Job Number: Page: 17 of 22 9 WAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME DATE Stamko Development T. 1. 10/19/2006 STEM NAME FLOOR AREA HVAC -1 1,155 Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAK COIL HTG. PEAK CFM TSensible Latent CFM I Sensible 2,739 34,609 5,634 562 23,597 0 1,730 1,180 0 0 23 9,142 1,44 231 10,680 0 0 1,730 1,180 47,2121 7,0751 E::"8 Carrier 50JX0605 37,872 17,569 0 Total Adjusted System Output37,872 17,569 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK Jul 3 pm Jan 12 am EATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26.0°F 64.4°F 110.0°F 110.0°F O Ducts Outside Air Supply Air 231 cfm 109.4 °F Heating Coil Supply Fan 2000 cfm ROOMS 69.4 OF 70.0 °F Return Air Ducts S :DOLING SYSTEM PSYCHROMETRICS (Airstream Temperatures at Time of Cooling Peak) 12.0/77.9°F 79.1/67.4°F 61.3/60.4°F 61.3/60.4°F O Supply Air Ducts Outside Air 231 cfm Cooling Coil Supply Fan 62.1 / 60.7 OF 2000 cfm 64.2% R.H. ROOMS 74.8/65.8 °F 74.0 / 65.5 OF 1110� 0 - Return Air Ducts EnergyPro 4.2 by EnergySoft User Number: 6712 Job Number: Paae:18 of 22 1 ROOM LOAD SUMMARY EnergyPro By EnergySoft User Number: User Job Number: Page: 19 of 22 PROJECT NAME Stamko Development T. 1. DATE 10/19/2006 STEM NAME HVAC -1 FLOOR AREA 1,155 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK ZONE NAME ROOM NAME Mult. CFM SENSIBLE LATENT CFM SENSIBLE LATENT CFM SENSIBLE Suite 4 Suite 4 1 2,739 34,609 5,634 2,739 34,609 5,634 562 23,597 PAGE TOTAL 1 2,736 34,606 5,634 562 23,597 TOTAL 1 2,739 34,609 5,634 562 23,597 EnergyPro By EnergySoft User Number: User Job Number: Page: 19 of 22 ROOM HEATING PEAK LOADS ro.ect Title Date amko Development T.I. 110/19/2006 Room Information Desi n Conditions Room Name Suite Time of Peak Jan 12 am Floor Area 1,155 Outdoor Dry Bulb Temperature 26OF Indoor Dry Bulb Temperature 70 OF Conduction Area Ll -Value AT OF Btu/hr Metal Tint 1155.0 x x X X X X X x X X x X x X X X x X x X x X X x X X x X x x x x x x X x x x X 0.0340 x x X X x X X x x x x X x X X x X X X x x x x x x x x X x x x X x x X X x x X 44 = = = = = = = = = = = = = = = = = = = = = = = = = = = 1,728 125.0 0.0740 44 407 60.0 0.7200 44 1,901 30.0 0.7200 44 950 25.0 0.7200 44 792 624.0 0.1100 44 3,020 219.0 0.0740 44 713 21.0 0.7000 44 647 624.0 0,1100 44 .020 perimeter = 156.0 0.7300 44 .3 5,011 Items shown with an asterisk (•rr) denote conduction through an interior surface to another room. Page Total: 18 189 Infiltration:I1 1.001 x 1.064 x 1 155 x 12.00 x 0.500 /6] x 0 = 5408 chedule Air Sensible Area Ceiling Height ACH pT Fraction TOTAL HOURLY HEAT LOSS FOR ROOM 23,597 EnergyPro 4.2 by EnergySoft User Number: 6712 Job Number: Page:20 of 22 ROOM COOLING PEAK LOADS Project Title Date Stamko Development T.I. 10/19/2006 ROOM INFORMATION DESIGN CONDITIONS Room Name Suite Time of Peak Jul 3 pm Floor Area 1,155 Outdoor Dry Bulb Temperature 112 tk Indoor Dry Bulb Temperature 74`F Outdoor Wet Bulb Temperature 78 OF Conduction 30 Roof (R.30.2x10.24 19 Wall W.19.2x6.16 Double Metal Tint 11 Partition Wall W.11.2x4.16 19 Wall W.19.24.16 Metal Door -11 Partition Wall W.11.2x4.16 Area X X X X X X X X X U -Value 1,155.0 0.0340 125.0 0.0740 115.0 0.7200 624.0 0.1100 219.0 0.0740 21.0 0.7000 624.0 0.1100 0.657 0.832 (N) 25.0 1. Design Equivalent Temperature Difference (DETD) Items shown with an asterisk (') denote conduction through an interior surface to another room. Solar Gain X X X X X X X X X DETD 1 = = = = = = = = = 72.5 37.8 27.1 39.5 40.3 39.1 57.6 60.0 41 Page Total Orientation Area X X X X X X x X x X SGF X X X X X X x X x x SC Weighting x X X x X x X X X X Factor = = = = = = = = = = (N) 60.0 41 0.657 0.832 (N) 30.0 41 0.657 0.832 (N) 25.0 41 0.657 0.832 Page Total Btu/hr 2,846 350 2,245 2,709 653 575 3,952 13 330 Btu/hr 1,344 672 560 2 576 Sched. Weighting Internal Gain Frac. Area Heat Gain Factor Btu/hr i hts 1.0 X 1,155 X 1.342 Watts/sqft X 3.41 Btuh/Watt X 0.999 = 5,285 ccu ants 1.0 X 1,155 X 300 Btuh/OCC. / 10 sqft/occ. x 1.00 = 3,465 Receptacle 1.0c X 1,155 X 1.340 Watts/sgft x 3.41 Btuh/Watt X 1.00 = 5,282 rocess 1.0c X 1,155 x 0.000 Watts/sqft X 3.41 Btuh/Watt X 1.00 = 0 Infiltration: 1.00 x 1.064 x 1 155 x 12.00 x 0.50 /601 x 38 = 4_6711 chedule Air Sensible Area Ceiling Height ACH AT Fraction TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 34,609 Sched. Latent Gain Frac. Area Heat Gain Btu/hr ccu ants 1.00 x 1 155 x 300 Btuh/OCC. / 100 sgft/occ. = 3 465 Receptacle 1.00 x x 000 Watts/sgft x 34131 Btuh/Watt = Process 1.00 X 1,155 x 0.000 Watts/sgft x 1 3.413 Btuh[Watt = 0 Infiltration: x x 1 1 x x / 60] x = 2169 chedule Air Latent Area Ceiling Height ACH pyy EnergyPro By Energ Soft User Number: User Page:21 of 22 r L ROOM COOLING COIL LOADS Project Title Stamko Development T.I. ___]"Date 10/19/2006 ROOM INFORMATION DESIGN CONDITIONS SC Room Name Suite Time of Peak Jul 3 pm Floor Area 1,155 Outdoor Dry Bulb Temperature 112 `k Indoor Dry Bulb Temperature 74`k Outdoor Wet Bulb Temperature 78 OF Conduction 30 Roof (R.30.2x10.24) 19 Wall .19.2x6.16 Double Metal Tint 11 Partition Wall W.11.2x4.16 19 Wall W.19.2x6.16 Metal Door -11 Partition Wall W.11.2x4.16 Area 1,155.0 125.0 115.0 624.0 1. Design Equivalent Temperature Difference (DETD) Items shown with an asterisk (') denote conduction through an interior surface to another room. Solar Gain ow U -Value 1 0.03401 1 0.11001 DETD t 72.5 = 37.8 = 27.1 = 39.5 = 40.3 = 39.1 = 57.6 = Page Total Orientation Area X X X x x x x X X X SGF X X X x x x x x X x SC Weighting X X X x x x x X x X Factor = = = = = = = = = = (N) 60.0 41 0.657 0.832 (N) 30.0 41 0.657 0.832 (N) 25.0 41 0.657 0.832 Page Total Btu/hr 2,846 350 2,245 2,709 653 575 3,952 13 330 Btu/hr Sched. Weighting Internal Gain Frac. Area Heat Gain Factor Btu/hr i hts 1.0 X 1,155 X 1.342 Watts/sgft X 3.41 Btuh/Watt X 0.999 = 5,285 ccu ants 1.0 X 1,155 X 300 Btuh/OCC. / 10 sqft/occ. X 1.00 = 3,465 Receptacle 1.0 X 1,155 X 1.340 Watts/sqft x 3.41 Btuh/Watt X 1.00 = 5,282 rocess 1.0 X 1,155 x 0.000 Watts/sgft x 3.41 Btuh/Watt X 1.00 = 0 Infiltration: 1.00 X 1.064 X 1 155 X 12.00 X 6] X 38 = 4 671 chedule Air Sensible Area Ceiling Height ACH OT Fraction TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 34,609 Sched. Latent Gain Frac. Area Heat Gain Btu/hr ccu ants 1.00 X 1 155 X 300 Btuh/OCC. / 100 sgft/occ. = 3 465 Receptacle 1 o x x 0 onn Watts/sgft x 4131 Btuh/Watt = Process 1.00 X 1,155 X 0.000 Watts/sqft X 3.413 Btuh[Watt = o 1 Infiltration: x x x x / 6] x chedule Air Latent Area Ceiling Height ACH pyy EnergyPro By EnergySoft User Number: User Page: 22 of 22