07-0224 (RC)1+
P.O. BOX 1504
78-495 CALLE TAMPICO
LA QUINTA, CALIFORNIA 92253
Application Number. r 07-00000224
Property Address: L'79255 -HIGHWAY 111 STE
APN: 649-030-999-8 -30420
Application description: REMODEL - COMMERCIAL
Property Zoning: REGIONAL COMMERCIAL
Application valuation: 25000
c&t�P4'4Qumm
BUILDING & SAFETY DEPARTMENT
BUILDING PERMIT
Applicant: Architect or Engineer:
--------------------------------------------------
LICENSED CONTRACTOR'S DECLARATION
hereby affirm under penalty of perju that I am licensed un r provisions of,Chapter 9 (commencing with
Section 7000) of Division 3 of the B iness and P fession s de, and my License is in full force and effect.
License Cl ss: r1 ce a No.: 762799
Date 041 Contractor:
OWNER -BUILDER DECLARATION
I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the
following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to
construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the
permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State
License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or
that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by
any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars 1$5001.:
(_) I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and
the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The
Contractors' State License Law does not apply to an owner of property who builds or improves thereon,
and who does the work himself or herself through his or her own employees, provided that the
improvements are not intended or offered for sale. If, however, the building or improvement is sold within
one year of completion, the owner -builder will have the burden of proving that he or she did not build or
improve for the purpose of sale.).
(_ 1 I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec.
7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of
property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed
pursuant to the Contractors' State License Law.).
I—) I am exempt under Sec. , B.&P.C. for this reason
Date: Owner:
CONSTRUCTION LENDING AGENCY
I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the
work for which this permit is issued (Sec. 3097, Civ. C.).
Lender's Name:
Lender's Address:
LQPERA11T
Owner:
STAMKO DEV CO
C/O PROVIDENT FINANCIAL MGMT
10345 W OLYMPIC BLVD 2 FL
LOS ANGELES, CA 90064 .
VOICE (760) 777-7012
FAX (760) 777-7011
INSPECTIONS (760) 7,77-7153
Date: 1/31/07
Contractor:
STAMKO DEVELOPMENT CO L PKOWYOFLAQUINJU
6080 CENTER DR, #668
LOS ANGELES, CA 90045"� ZO(310)242-5637Lic. No.: 762799
------------------
WORKER'S COMPENSATION DECLARATION
I hereby affirm under penalty of perjury one of the following declarations:
_ I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided
- for by Section 3700 of the Labor Code, for the performance of the work for which this permit is
issued.
I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor
Code, for the performance of the work for which this permit is issued. My workers' compensation
insurance carrier and policy number are:
Carrier STATE FUND Policy Number 1557214-2006
I certify that, in the pe rmance of the work for w ' permit is issued, I shall not employ any
person in any mann r o as to become subject o the w kers' compensation laws of California,
and agree that, if I Id becomes ject to a worker compensation provisions of Section
33700 of the Labor o e, I shall f with co ply with ose provisions.
Dat . 7 d • Applicant:
WARNING: FAILURE TO SECURE W RKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL
SUBJECT AN EMPLOYER TO CRIMIN L PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND
DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN
SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES.
APPLICANT ACKNOWLEDGEMENT
IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the
conditions and restrictions set forth on this application.
1. Each person upon whose behalf this application is made, each person at whose request and for
whose benefit work is performed under or pursuant to any permit issued as a result of this application,
the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City
of La Quinta, its officers, agents and employees for any act or omission related to the work being
performed under or following issuance of this permit.
2. Any permit issued as a result of this application becomes null and void if work is not commenced
within 180 days from date of issuance of suc permit, or cessation of work for 180 days will subject
permit to cancellation.
I certify that I have read this application and state that a bove information is correagreecomply with all
city and county ordinances and state laws relating to b i ing constructs , and herepresentatives
of this co my o mann er upon the above-mentioned prop y for inspe n purposes.
Dat 0 ` Signature (Applicant or Agent):
LQPERAIIT
t
Application Number . . . . . 07-00000224
Permit BUILDING PERMIT
Additional desc .
Permit Fee . . . . 252.00 _ Plan Check
Fee
163.80
Issue Date . . . . Valuation
. . . .
25000
:Expiration Date 7/30/07
Qty Unit Charge Per
Extension
BASE FEE
45..00
23.00 9.0000 THOU BLDG 2,001-25,000
----------------------------------------------------------------------------
207.00
Permit ELECT - ADD/ALT/REM
^
Additional desc .
Permit Fee 33.00 Plan Check
Fee
8.25
Issue Date Valuation
. . .
0'
Expiration Date 7/30/07•
Qty Unit Charge Per
Extension
BASE FEE
15.00
900.00 .0200 ELEC GARAGE OR NON-RESIDENTIAL,
------------------ ------------------------------------------------------------
18.00
Permit ` . . . MECHANICAL
Additional desc .
Permit Fee . . . . 24.00 Plan Check
Fee
6.00
- Issue Date . . IValuation
. . .`.
0
Expiration Date 7/30/07
Qty Unit Charge Per
Extension
BASE FEE
15.00
1.00 9.0000 EA MECH APPL REP/ALT/ADD
-------=--------------=-----------------------------------------------------
9.00
Permit PLUMBING
Additional desc .
Permit Fee . . . . 70.50 Plan Check
Fee
17.63
Issue Date Valuation
0
Expiration Date 7/30/07..
Qty Unit Charge Per
Extension
BASE FEE
15.00
8.00 6.0000 EA PLB FIXTURE
48.00
1.00 7.5000 EA PLB WATER HEATER/VENT
7.50
----------------------------------------------------------------------------
Special Notes and Comments
TENANT IMPROVEMENT DIPPIN DOTS.900•SQ.
FT. January 31, 2007 9:10:34 AM
LQPERAIIT
t
Application'Number
07-00000224
Special Notes and
Comments
jjohnson
Fee summary
Charged
Paid•.
Credited
Due
Permit Fee Total
379.50
.00
.00
379.50
Plan Check Total
_.195.68
.0.0
.00
195.68
Grand Total
575.18
.00
.00
575.18
LQPERHIIT
Bl�CN78
City of La Quinta
Building U Safety Division
P.O. Box 1504, 78-495 Calle Tampico
La Quinta, CA 92253 - (760) 777-7012
Building Permit Application and Tracking Sheet
Permit # Z,lJ.
0
Project Address: Owner's Name: V,1bb �� e -
A. P. Number: Address:
Legal Description: City, ST, Zip:
Contractor: IJ4 V—c�, Telephone:
Address: C Project Description: ^`
lA v�
City, ST, Zip: L4S, t K S `)
Telephone: 771 It W
State Lic. # : City Lic. #:
a
Arch., Engr., Designer: rte L� U
OP
Address: n F1,
City, ST, Zip:
Telephone: rif �t�j Construction T 8
ype: 1� �3 Occupancy:
State Lic. #: Project type (circle one): g� Add'n Alter Repair Demo
Name of Contact Person: to L V A Sq. Ft.: # Stories: # Units:
Telephone # of Contact Person:
Lob
Estimated Value of Project:
APPLICANT: DO NOT WRITE BELOW THIS UNE
#
Submittal
Req'd
Rec'd
TRACKING
PERMIT FEES
(� AAVDll�
Plan Sets s
Plan Check submitted
IQ p7
Item
Amount
Structural Cates.
Reviewed, ready for corrections
Plan Check Deposit
Truss Calcs.
Called Contact Person
Plan Check Balance
Energy Calcs.
Plans picked up
Construction
Flood plain plan
Plans resubmitted
Mechanical
Grading plan
2" Review, ready for correction(r.e
3
Electrical
Subcoutactor List
Called Contact Person11363
Plumbing
Grant Deed
Plans picked up
S.M.I.
H.O.A. Approval
Plans resubmitted
Grading
IN HOUSE:-
''' Review, ready for corrections/issue
Developer Impact Fee
Planning Approval
Called Contact Person
A.I.P.P.
Pub. Wks. Appr
Date of permit issue
jl
School Fees
I
�1Y4L
44
CV I
�.
Total Permit Fees
i ly 1 U-1 CN MgRD ( in nov5 )
19107 `P c vp (i/)P�Atcv "
/z¢/o7 OP 4MRwm
COACHELLA VALLEY WATER DISTRICT ASSESSOR'S PARCEL NUMBER
85-995 Avenue 52
Coachella, California 92236
(760) 398-2651
APPLICATION FOR WASTEWATER INTERCEPTOR/SEPARATOR APPROVAL
APPLICANT:' Submit this form with a copy of a SCALED plot plan (1" = 20' to 1" = 40' SCALE) drawn to District specifications. A nonrefundable filing fee is required
when the application is submitted. Check must be made payable to the Coachella Valley Water District. Approval of this application shall remain valid -for a period
not to exceed one (1) year from date of payment.
Plan Check No.
Agent, Contmcto Con t Person Address State Zip Telephone
," - \-I ri FP, -4h nR ity d r-,•(> . CA ra'18.1 PA
Owner Address City State Zip Telephone
l L Ser, LA iDUK44 %ZM ('174-6too
Job Property Address City Zi
-I •ate I I I s� S Q IN Cd • f -'Uzip
Legal Description I IDBA .
PLEASE COMPLETE THIS SECTION FOR REVIEW OF FOOD ESTABLISHMENTS
NOTE: PLANS WILL NOT BE ACCEPTED UNLESS THIS APPLICATION IS COMPLETE AND THE PLAN CHECK FEE IS PAID.
GENERAL CONSTRUCTION:
Type of Construction -
New
lO Pte.
New Food Facility V Remodel of Existing Food Establishment Hours of Operation Seating Capacity: Internal External
External Seating with Misters'or Heaters Bar with Food Service Bar Nonfood Service Water Softener
Service:
Multiservice (reusable) Single Service (disposable)
OWNER/REPRESENTATIVE DECLARATION: I certify that I have read the entire application and state that all information is correct. I understand that the amount of fee
paid is based on my declaration of information on this form and that incorrect information is grounds for denial of the submitted plans. I also understand that plans will be
discarded if not picked up within sixty (60) days of approval or denial and that no inspection of my establishment will be conducted, or approval granted to operate, until all
proper information ed has received and plans have been approved and returned.
Signature � - Date 1 1�
No. of Systems
❑ New ❑ Existing
❑ Replacement ❑ Addition
❑ Connect to Sewer
No. Dwelling Units
Fixture Units
❑ Sand/Oil
❑ Grease Interceptor
❑ Lim Trap
❑ Clarifier
Grease hnt meptor Waived
Gal.
Approved ❑ Denied ❑ Conditional Approval*
*See Remarks
Signature r�jeel
Date
Fee S , -5-0 oa
Check No. , 4
Date Lo D
Initial
CVWD-921
Plan Check #
RIVERSIDE COUNTY COMMUNITY HEALTH AGENCY
A. DEPARTMENT OF ENVIRONMENTAL HEALTH
FOOD ESTABLISHMENT PLAN APPROVAL NOTICE
Date 1/17/07
Project Name Dippin Dots Address 79-255 Hwy 111 Ste. 5, La Quinta
Plans Submitted by Larry Lenarz Phone 360-0106
Owner Larry & Lucinda Address 44375 Buttercup Ln. La Quinta Phone 360-0106
Lenarz
The plans are now approved subject to the conditions listed below and the attached compliance sheet.
1. Provide a grease interceptor sizing letter from the appropriate agency prior to final approval.
2. The 3 -compartment sink must have minimum 18"xl8" drainboards.
3. The air curtain must be an approved high velocity air curtain capable of producing 1600 fpm at 3' above the floor. (ie. Mars
NCH, NH).
4. All sneeze guard protection will be evaluated at on site inspections.
5. Provide a 12" high splash guard on the right side of the hand sink in the service area. See redline correction on sheet A 2.75
6. Provide a minimum 46,000 BTU water heater.
7. Floor sinks must not be buried under equipment or cabinetry. (ie. the floor sink under the front service area hand sink.) Floor
sinks must be at least half exposed with a curb around the backside coved with approved 3/8" radius cove base tile.
8. Provide approved integral 3/8" radius cove base in conjunction with the quarry or ceramic tile. Slim foot tile is not approved
on tot) of ceramic or auarry tile.
9. All wall paint and interior surfaces of all cabinetry must be light in color. Paints must be gloss or semi gloss finish.
CONSTRUCTION INSPECTIONS: Contact the Plan Checker for a Preliminary Inspection when construction is
approximately 80% complete, with plumbing, rough ventilation, and rough equipment installed. Request for
inspection should be made at least five (5) working days in advance.
A FINAL INSPECTION MUST be made upon completion of ALL work including finished details. APPROVAL to
operate shall not be granted, or remodeled areas approved to operate, until the facility has passed the FINAL
INSPECTION, .and "APPLICATION TO OPERATE" has been completed and PERMIT FEES have been paid.
Request for inspection should be made at least five (5) working days in advance.
PLANS CHECKED BY Kelly Amon R.E.H:S. III Phone (760) 320-1048
I acknowledge the corrections noted
construction:
Signature
Company Name.
icated on the plans and agree to incorporate them during
Date - 'nl- 0
brc k L ti I A%S %'Cl kvso
DEH -SAN -178 (Rev 2/06)
V
Corona
Hemet
Indio'
Murrieta
Palm Springs
Riverside
2275 S. Main St Suite 204
800 S. Sanderson
. 47-950 Arabia St "A"
.38740 Sky Canyon Dr
2500 N. Palm Canyon Dr
4065 County Cir
(951) 273-9140
(951) 766-2824
(760) 863-8287
(951) 461-0284
(760) 320-1048
(951) 358-5172
Fax (951) 520-8319
Fax (951) 766-7874
Fax (760) 863-8303
Fax (951) 461-0245
Fax (760) 320-1470
Fax (951) 358-5017
John R. Hawkins
Fire Chief
Proudly serving the
Unincorporated
Areas of Riverside
County and the
Cities of:
Banning
Beaumont
4.
Calimesa
Canyon Lake
4.
Coachella
Desert Hot Springs
Indian Wells
4.
Indio
Lake Elsinore
La Quinta
4.
Moreno Valley
4.
Palm Desert
Perris
Rancho Mirage
4.
San Jacinto
Temecula
Board of Supervisors
Bob Buster,
District 1
John Tavaglione,
District 2
Jim Venable,
District 3
Roy Wilson,
District 4
Marion Ashley,
District 5
RIVERSIDE COUNTY FIRE DEPARTMENT
In cooperation with the
California Department of Forestry and Fire Protection
210 West San Jacinto Avenue • Perris, California 92570 • (909) 940-6900 • Pax(909)940-69'1-0
October 11, 2006
Gabriel Lujan
45175 Panorama Drive, Ste A
Palm Desert, CA 92260
RE: TENANT IMPROVEMENT PLAN CHECK
LAQ-06-TI-084 / Dippin Dots at 79255 Hwy 111, Ste 5, La Quinta, CA
You have been issued a release for a tenant improvement on an existing building. THIS IS
NOT AN OCCUPANCY PERMIT.
It is prohibited to use/process or store any materials in this occupancy that would classify it
as an "H" occupancy per Sec. 307 of the 2000 UBC.
THE FOLLOWING CONDITIONS MUST BE MET PRIOR TO INSPECTION:
Install door hardware and exit signs as per Chapter 10 of the 2000 UBC
Install Knox Lock Boxes, Models 4400, 3200 or 1300, mounted per recommended standard
of the. Knox Company. Plans must be submitted to the Fire Department for approval of
mounting location/position and operating standards. Special forms are available from this
office for the ordering of the Key Lock Boxes. This form must be authorized and signed by
this office for the correctly coded system to be purchased. If the building/facility is protected
with a fire alarm system or burglar alarm system, the lock boxes will require "tamper"
monitoring.
A minimum 2A10BC Fire Extinguisher, (State Fire Marshal Approved) must be mounted in a
visible location within 75' walking distance from any point in your building or suite. Fire
extinguishers can be installed by a licensed extinguisher company with a State Fire Marshal
service tag attached to the extinguisher, or purchased from a retail store with a sales receipt
attached. A licensed fire extinguisher company must service extinguisher yearly.
ELECTRICAL PANEL BOX:
All breakers must be labeled and a clearance of 36 inches must be maintained around the
panel at all times.
OTHER REQUIREMENTS:
Approved building address shall be placed in such a position a to be plainly visible and
legible from the street. Said numbers shall contrast with their background.
A durable sign stating"This door to remain unlocked during business hours" shall be placed.
on or adjacent to the front exit door. - The sign shall be in letters not less than one inch high
on a contrasting background.
EMERGENCY SERVICES DIVISION . PLANNING SECTION • INDIO OFFICE
82-675 Highway 111, 2nd FI., Indio, CA 92201 • (760) 863.8886 • Fax (760) 863-7072
F .
Applicant/installer.shall be responsible to contact the Fire Department to schedule
inspections. A re-inspectiortfee will be required if more than one (1) inspection is necessary.
Requests for inspections are:to be made at least 72 hours in advance and may be arranged
by calling (760) 863-8886. ,
All questions regarding the meaning of these conditions should be referred to the Fire
Department Planning & Engineering Staff at (760) 863-8886.
Sincerely,
Tracy Hobday
Chief Fire Department Planner
By: O'C
Sonia Cooley
Fire Safety Specialist
' COUNTY OF RIVERSIDE COMMUNITY HEALTH AGENCY
DEPARTMENT OF ENVIRONMENTAL HEALTH
ENVIRONMENTAL HEALTH SERVICES
SUPPLEMENTAL REPORT TO SAN. FORM # DATE 3
SUBJECT //� {�(�/� r //"i PERMIT NO. &-A S1".
ADDRESS`7ZSS/ I ►�l �r�. L�.� r�U/�7G
INSPECTOR
REMARKS:S`y�j
m;vl,
vi► G S www /�
f14W 5���V o
U
-ha- Lmd, .u���1
V
DEH -SAN -118 (Rev 8/02) Distribution: WHITE—Office; CANARY—Owner; PINK—Office
COUNTY OF'RIVERSIDIE- COMMUNITY HEALTH AGENCY
DEPARTMENT OF ENVIRONMENTAL HEALTH
ENVIRONMENTAL HEALTH SERVICES
SUPPLEMENTAL REPORT TO SAN. FORM # DATE Lo
SUBJECT llf2(2111 P01 PERMIT NO.
LA -A.
ADDRESS —7 V4 t1l
- INSPECTOR TODYWObS-)
REMARKS: c>e c
r))- 6 1; OtkL4, 0 t K 6 h1b UD -y A -P V 0 �Lnd Inv 47UL Lfas 0-(
AppnveA 4v opUcc-c,,- C,D-vl-A*
U�,A ec` (k VIA Q. �qyp\-) A-c--q,,-yyi D4 ke.,u A, LL C -w, LA -e,-3
1�. to (e c �-eA do I?— A I cl -61 So I.-
DEH -SAN -118
J
1 1
r ..
Certificate of Occu ancy,
OF Building & Safety Department
This Certificate is issued pursuant to the requirements of Section .109 of the California Building,
"
Code, certifying that, at the time of issuance, this structure was in compliance with the
provisions of the Building Code and the various ordinances of the City regulating building
construction and/,or use.
BUILDING ADDRESS: 79-255 HIGHWAY 111 STE #5.
Use classification: COMMERCIAL (DIPPIN DOTS) -Building Permit No.: 07-224
Occupancy Group: B Type of Construction: VN Land Use Zone: CR
Owner of Building: STAMKO DEV CO Address: 10345 W. OLYMPIC BLVD 2 FIL
F
City,, ST, ZIP: LOS ANGELES, CA 90064
By: STEVE TRAXEL
Date: APRIL 4, 2007
Building Official
u
POST IN A CONSPICUOUS PLACE
Z
r
TITLE 24 REPORT
Title 24 Report for:
Stamko Development T.I.-Dipping Dots
79-255 Highway 111, Suite 5
La Quinta, Ca 92253
Project Designer:
Gabriel Lujan and Associates
45-175 Panorama Dr., Suite A
Palm Desert, Ca 92260
(760) 568-8545
Report Prepared By:
Tim Scott
Scott Design & Title 24
77085 Michigan Dr.
Palm Desert, CA 92211
(760) 200-4780
Job Number:
Date:
8/24/2006
CITY OF LA QUINTA
BUILDING & SAFETY DEPT.
APPROVED
FOR CONSTRUCTION
BY,
The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is
authorized by the California Energy Commission for use with both the Residential and Nonresidential 2005 Building Energy Efficiency Standards.
This program developed by EnergySoft, LLC - www.energysoft.com.
EnergyPro 4.1 by EnergySoft Job Number: User Number: 6712
4
PERFORMANCE CERTIFICATE OF COMPLIANCE Part 1 Of 3 PERF -1
PROJECT NAME
This Certificate of Compliance lists the building features and performance specifications needed to comply with Title 24, Parts 1 and 6 of the
DATE
Stamko Development T.I.-Dipping Dots
DOCUMENTATION AUTHOR
Tim Scott
8/24/2006
PROJECT ADDRESS
The Principal Designer hereby certifys that the proposed building design represented in this set of construction documents is
BUILDING CONDITIONED FLOOR AREAE
79-255 Highway 111, Suite 5 La Quinta
through 118, and 140, 142, 143 or 149 of Title 24, Part 6.
ZONE
CLIMAT15
PRINCIPAL DESIGNER - ENVELOPE
TELEPHONE
Building Permit #
Gabriel Lujan and Associates
(760) 568-8545
PHASE OF CONSTRUCTION
DOCUMENTATION AUTHOR
TELEPHONE
Checked by/Date
Scott Design & Title 24
(760) 200-4780
Enforcement Agency Use
GENERAL INFORMATION
This Certificate of Compliance lists the building features and performance specifications needed to comply with Title 24, Parts 1 and 6 of the
California Code of Regulations. This certificate applies only to a Building using the performance compliance approach.
The documentation preparer hereby certifies that the documentation is a urate and complete.
DOCUMENTATION AUTHOR
Tim Scott
DATE OF PLANS
DAT
The Principal Designer hereby certifys that the proposed building design represented in this set of construction documents is
BUILDING CONDITIONED FLOOR AREAE
900 ScI.Ft.
through 118, and 140, 142, 143 or 149 of Title 24, Part 6.
ZONE
CLIMAT15
BUILDING TYPE
®
NONRESIDENTIAL HIGH RISE RESIDENTIAL
❑ ❑ R 2. 1 affirm that I am eligible under the provisions of Division 3 of the Business and Professions Code Section
HOTEL/MOTEL GUEST ROOM
PHASE OF CONSTRUCTION
®
NEW CONSTRUCTION ADDITION
Code Sections 5537, 5538, and 6737.1. (These sections of the Business and Professions Code are printed in
full in the Nonresidential Manual.)
EXISTING + ADDITION/ALTERATION
STATEMENT OF COMPLIANCE
This Certificate of Compliance lists the building features and performance specifications needed to comply with Title 24, Parts 1 and 6 of the
California Code of Regulations. This certificate applies only to a Building using the performance compliance approach.
The documentation preparer hereby certifies that the documentation is a urate and complete.
DOCUMENTATION AUTHOR
Tim Scott
SIG A,
DAT
The Principal Designer hereby certifys that the proposed building design represented in this set of construction documents is
consistent with the other compliance forms and worksheets, with the specifications, and with any other calculations submitted with this
permit application. The proposed building as designed meets the energy efficiency requirements contained in sections 110, 116,
through 118, and 140, 142, 143 or 149 of Title 24, Part 6.
ENV. LTG. MECH.
❑ ❑ ❑ 1. 1 hereby affirm that I am eligible under the provisions of Division 3 of the Business and Professions Code to
sign this document as the person responsible for its preparation; and that I am licensed in the State of
California as a civil engineer, mechanical engineer, or I am a licensed architect.
❑ ❑ R 2. 1 affirm that I am eligible under the provisions of Division 3 of the Business and Professions Code Section
5537.2 or 6737.3 to sign this document as the person responsible for its preparation; and that I am a licensed
contractor performing this work.
❑ ❑ ❑ 3. 1 affirm that I am eligible under Division 3 of the Business and Professions Code to sign this document
because it pertains to a structure or type of work described as exempt pursuant to Business and Professions
Code Sections 5537, 5538, and 6737.1. (These sections of the Business and Professions Code are printed in
full in the Nonresidential Manual.)
ENVELOPE COMPLIANCE
Indicate location on plans of Note Block for Mandatory Measures
ENV -1
Required Forms
PRINCIPAL ENVELOPE DESIGNER - NAME
SIGNATURE
LIC. NO.
DATE
Gabriel Lu'an and Associates
LIGHTING COMPLIANCE
Indicate location on plans of Note Block for Mandatory Measures
LTG -1, LTG -2
Required Forms
PRINCIPAL LIGHTING DESIGNER - NAME
Gabriel Wan and Associates
SIGNATURE
LIC. NO.
DATE
MECHANICAL COMPLIANCE
Indicate location on plans of Note Block for Mandatory Measures
ECH-1, MECH-2 MECH-3 MECH-5
Require orms
RINCIPAL MECHANICAL DESIGNER - NAME
IG U E
LIC. NO.
DAzE
FScott Design & Title 24
EnergyPro 4.1 by EnergySoft User Number: 6712 Job Number: Pape:3 of 24 1
PERFORMANCE CERTIFICATE OF COMPLIANCE Part 2 of 3 PERF -1
PROJECT NAME DATE
Stamko Development T.I.-Dipping Dots 8/24/2006
ANNUAL TDV ENERGY USE SUMMARY kBtu/s ft- r
Standard Proposed Compliance
ENERGY COMPONENT Design Design Margin
Space Heating 2.63 0.05 2.58"°
Space Cooling 520.17 440.74 79.42
Indoor Fans 111.90 114.48 -2.58
Heat Rejection 0.00 0.00 0.00
Pumps & Misc. 0.00 0.00 0.00
Domestic Hot Water 57.40 57.89 -0.49
Lighting 165.26 174.52 -9.25
Receptacle 82.18 82.18 0.00
Process o.o0 0.00 0.00
TOTALS: 939.54 869.86 69.68
Percent better than Standard: 7.4% ( 7.4% excluding
( standard Proposed
1
............................................
50 100 150 200250 300 350 400 450 500
kBtu/sgR-yr
�
0
process)
BUILDING COMPLIES
GENERAL INFORMATION
Building Orientation (N)Odeg Conditioned Floor Area 900 sgft.
Number of Stories 1 Unconditioned Floor Area 0 sgft.
Number of Systems 1 Conditioned Footprint Area 900 sgft.
Number of Zones F 11 Fuel Type Natural Gas
Orientation Gross Area Glazing Area Glazing Ratio
Front Elevation (N) 180 sgft. 60 sgft. 33.3%
Left Elevation (E) 720 sgft. 0 sgft. 0.0%
Rear Elevation (S) 180 sgft. 0 sgft. 0.0%
Right Elevation (W)l 720 sgft. 0 sgft. 0.0%
Total 1,800 sgft. 1 60 sgft. 3.3%
Roof 900 sgft. E=� sgft. 0.0%
Standard Proposed
Lighting Power Density 1.500 W/sgft. 1.584 W/sgft.
Prescriptive Env. Heat Loss 249 Btu/h 253 Btu/h
Prescriptive Env. Heat Gain 18,803 Btu/h-F 19,575 Btu/h-F
Remarks:
Run Initiation Time: 08/24/06 14:19:00 Run Code: 1156454340
EnergyPro 4.1 by EnergySoft User Number: 6712 Job Number: Page:4 of 24
PERFORMANCE CERTIFICATE OF COMPLIANCE Part 3 of 3 PERF -1
PROJECT NAME
Stamko Development T.I.-Dipping Dots
DATE
8/24/2006
ZONE INFORMATION
System Name Zone Name Occupancy Type
Floor
Area
(sqft.)
Inst.
LPD
(W/sf)1
Ctrl. Allowed LPD
Credits > Area Tailored
(W/sf)2 (Wis 3 (W/S4
Proc.
toads
(W/sf)
HVAC -1 Suite 5 Comp Bldg Retail and Wholesale
900
1.58
Notes: 1. See LTG -2-C 2. See LTG -4-C 3. See LTG -5-C
(items marked with asterisk, see LTG -2 -C by others) (by others)
4. See LTG -6-C
Items above require special documentation
EXCEPTIONAL CONDITIONS COMPLIANCE CHECKLIST
The local enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification
and documentation, and special verification to be used with the performance approach. The local enforcement agency determines the adequacy of
the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation
submitted.
The HVAC System "Carrier 50JX0605" is designated as 3 Phase, or is Exempted from the NAECA 13 SEER requirement.
di no exceptional features ustea in tors performance approach application have specifically been reviewed. Adequate written justification and
ocumentation for their use have been provided by the applicant.
Authorized Sianature or Stamo
EnergyPro 4.1 by EnergySoft User Number: 6712 Job Number: Page:5 of 24 1
CERTIFICATE OF COMPLIANCE ENV -1-C
NAME
Stamko Development T.I.-DiDDina Dots
OPAQUE SURFACES
DATE
8/24/2006
#
Surface
Type
Area
U -Fac.
Insulation
Cay. Cont.
Act.
Am.
Tilt
Cond'
Status
Joint Appendix
IV Reference
Location / Comments
1
Roof
900
0.034
R-30
R-0.0
0
0
New
02-A26
Suite 5
2
Wall
120
0.074
R-19
R-0.0
0
90
New
09-A5
Suite 5
3
Wall
720
0.110
R-11
R-0.0
90
90
New
09-A2
Suite 5
4
Wall
159
0.074
R-19
R-0.0
180
90
New
09-A5
Suite 5
5
Door
21
0.700
None
R-0.0
180
90
New
28-A2
Suite 5
6
Wall
720
0.110
R-11
R-0.0
270
90
New
09-A2
Suite 5
Existing, Altered, Removed)
FENESTRATION SURFACES
FIMore than or equal to 10,000 sq.ft. of site -built fenestration area must include a label certificate either issued by NFRC or provide a CEC Default Label Certificate using the default U -factors from
I
Standards Table 116-A and B. Certificate shall be filed in the contractors oroiect office dudno construction and in the buildino manaoers office after—f-Minn
#
Tvpe
Area U -Fac'
SHGC2
Act.
Am.
Cond.
Stat.
lGlazing Type
Location/
Comments
1
Window Front N
30 0.720 NFRC
0.59 NFRC
0
New
Double Metal Tint
Suite 5
2
Window Front N
24 0.720 NFRC
0.59 NFRC
0
New
Double Metal Tint
Suite 5
3
Window Front N
6 0.720 NFRC
0.59 NFRC
0
New
Double Metal Tint
Suite 5
1 D -tactor type: 116-A Default Table from Standards, Table NI -1 Default Table from the ACM Manual Appendix, NFRC Labeled value.
2 SHGC Type: 116-B Default Table from Standards, COG Center of Glass, NFRC Labeled Value
EXTERIOR SHADING
Window Overhang Left Fin Right Fin
## Exterior Shade Type SHGC Hgt. Wd. Len. H t. LExt.RExt. Dist. Len. H t. Dist. Len. H t.
1 None 0.76
2 None 0.76
3 None 0.76
MINIMUM SKYLIGHT AREA FOR LARGE ENCLOSED SPACES
❑The proposed building contains an enclosed space with floor area greater than 25,000 sq.ft, a ceiling height greater than 15 feet and a LPD for general lighting of at least 0.5 Wlsq.ft. If this
box Is checked, ENV4-C must be filled out when submitting under the Prescriptive Compliance Approach.
Run Initiation Time: 08/24/06 14:19:00 Run Code: 1156454340
EnergyPro 4.1 by EnergySoft User Number: 6712 Job Number: Page:6 of 24
CERTIFICATE OF COMPLIANCE (Part 1 of 3) LTG -1 -C
r
ROJECT NAME DATE
Stamko Development T.I.-Dipping Dots 8/24/2006
INSTALLED INDOOR LIGHTING POWER FOR CONDITIONED AND UNCONDITIONED SPACES
INSTALLED
WATTS
INSTALLED LIGHTING, CONDITIONED SPACES (From LTG -2-C) 1,426
PORTABLE LIGHTING (From LTG -3-C) 0
LIGHTING CONTROL CREDIT, CONDITIONED SPACES (From LTG -4-C) 0
CONDITIONED SPACE ADJUSTED INSTALLED LIGHTING POWER 1,426
INSTALLED LIGHTING, UNCONDITIONED SPACES (From LTG -2-C) 0
LIGHTING CONTROL CREDIT, UNCONDITIONED SPACES (From LTG -4-C) 0
UNCONDITIONED SPACE ADJUSTED INSTALLED LIGHTING POWER 0
ALLOWED INDOOR LIGHTING POWER FOR CONDITIONED SPACES
❑ COMPLETE BUILDING METHOD (From LTG -5-C) ALLOWED
❑ AREA CATEGORY METHOD (From LTG -5-C) WATTS
❑ TAILORED METHOD (From LTG -5-C) ALLOWED LIGHTING POWER 1,426
❑X PERFORMANCE METHOD
❑ COMMMON LIGHTING SYSTEM (From LTG -8-C)
ALLOWED INDOOR LIGHTING POWER FOR UNCONDITIONED SPACES From LTG -5-C) 0
MANDATORY INDOOR AND DAYLIGHTING AUTOMATIC CONTROLS
CONTROL LOCATION
(Room #)
CONTROL
IDENTIFICATION
CONTROLTYPE
(Auto Time Switch, Dimm
Check if
SPACE CONTROLLED kaylightingi
NOTE TO
FIELD
Run Initiation Time: 08/24/06 14:19:00 Run Code: 1156454340
EnergyPro 4.1 by EnergySoft User Number: 6712 Job Number: Paae:7 of 24
4
CERTIFICATE OF COMPLIANCE (Part 3 of 3) LTG -1-C-]
PROJECT NAME
Stamko Development T.I.-Dipping Dots
DATE
1 8/24/2006
Designer:
This form is to be used by the designer and attached to the plans. Listed below are all the acceptance
tests for lighting systems. The designer is required to check the boxes by all acceptance tests that
apply and list all equipment that require an acceptance test. If all equipment of a certain type requires
a test, list the equipment description and the number of systems to be tested in parentheses. The NJ
number designates the Section in the Appendix of the Nonresidential ACM Manual that describes the
test. Also indicate the person responsible for performing the tests (i.e. the installing contractor, design
professional or an agent selected by the owner). Since this form will be part of the plans, completion
of this section will allow the responsible party to budget for the scope of work appropriately.
Building Departments:
Before an occupancy permit is granted for a newly constructed building or space, or a new lighting
system system serving a building or space is operated for normal use, all control devices serving the
building or space shall be certified as meeting the Acceptance Requirements for Code Compliance.
In addition a Certificate of Acceptance, LTG -1-A, Forms shall be submitted to the building department
that:
A. Certifies plans, specifications, installation certificates, and operating and maintenance
information meet the requirements of§ 10-103(b) and Title 24 Part 6.
Test Description
Test Performed By:
O LTG -2-A: Lighting Control Acceptance Document
- Occupancy Sensor Acceptance
- Manual Daylight Controls Acceptance
- Automatic Time Switch Control Acceptance
Equipment requiring acceptance testing
O LTG -3-A: Automatic Daylighting Controls Acceptance Document
Equipment requiring acceptance testing
EnergyPro 4.1 by EnergySoft User Number: 6712 Job Number: Paoe:8 of 24 1
17 -
CERTIFICATE OF COMPLIANCE MECH-1-C
PROJECT NAME DATE
Stamko Development T.I.-Dippinq Dots 8/24/2006
uesigner:
This form is to be used by the designer and attached to the plans. Listed below are all the acceptance tests for mechanical systems. The designer is required to
check the boxes by all acceptance tests that apply and list all equipment that requires an acceptance test. If all equipment of a certain type requires a test, list the
equipment description and the number of systems to be tested in parentheses. The NJ number designates the Section in the Appendix of the Nonresidential
ACM Manual that describes the test. Also indicate the person responsible for performing the tests (i.e. the installing contractor, design professional or an agent
selected by the owner). Since this form will be part of the plans, completion of this section will allow the responsible party to budget for the scope of work
appropriately.
Building Departments:
SYSTEM ACCEPTANCE. Before an occupancy permit is granted for a newly constructed building or space, or a new space -conditioning system serving a
building or space is operated for normal use, all control devices serving the building or space shall be certified as meeting the Acceptance Requirements for
Code Compliance.
In addition a Certificate of Acceptance, MECH-I-A Form shall be submitted to the building department that certifies plans, specifications, installation
certificates, and operating and maintenance information meet the reauirements of Section 10-1 03(b) and Title 24 Part 6
STATEMENT OF COMPLIANCE
❑ MECH-2-A: Ventilation System Acceptance Document
-Variable Air Volume Systems Outdoor Air Acceptance
-Constant Air Volume Systems Outdoor Air Acceptance
Equipment requiring acceptance testing
Test required on all New systems both New Construction and Retrofit.
❑ MECH-3-A: Packaged HVAC Systems Acceptance Document
Equipment requiring acceptance testing
Test required on all New systems both New Construction and Retrofit.
❑ MECH-4-A: Air -Side Economizer Acceptance Document
Equipment requiring acceptance testing
Test required on all New systems both New Construction and Retrofit. Units with economizers that are installed at the factory and certified with the
commission do not require equipment testing but do require construction inspection.
❑ MECH-5-A: Air Distribution Acceptance Document
Equipment requiring acceptance testing
This test required If the unit serves 5, 000 fi2 of space or less and 25% or more of the ducts are in nonconditioned or semiconditioned space like an
attic. New systems that meet the above requirements. Retrofit systems that meet the above requirements and either extend ducts, replace ducts or
replace the packaged unit.
❑ MECH-6-A: Demand Control Ventilation Acceptance Document
Equipment requiring acceptance testing
All new DCV controls installed on new or existing packaged systems must be tested.
❑ MECH-7-A: Supply Fan Variable Flow Control Acceptance Document
Equipment requiring acceptance testing
All new VA fan volume controls installed on new or existing systems must be tested
❑ MECH-8-A: -Hydronic System Control Acceptance Document
-Variable Flow Controls Applies to chilled and hot water systems. ,
-Automatic Isolation Controls Applies to new boilers and chillers and the primary pumps are connected to a common header.
-Supply Water Temperature Reset Controls
Applies to new constant /low chilled and hot water systems that have a design capacity greater than or equal to 500,000 Btu/hr.
-Water-loop Heat Pump Controls
Applies to all new watertoop heat pump systems where the combined loop pumps are greater than 5 hp.
-Variable Frequency Controls Applies to all new distribution pumps on new variable flow chilled, hydronic heat pump
or condenser water systems where the pumps motors are greater than 5 hp.
Equipment requiring acceptance testing
EnergyPro 4.1 by EnergySoft User Number: 6712 Job Number: Page:9 of 24
N
4-
0
r
tf
N
0-
(D
C)
O
Q
IT
CV
00
w
Q
0
N
O
0
CD
0
O
U)
w
Q
Z
F -
w
w
O
a
0
(O
(O
O
C14
Iq
N
0
rn
a
Q
m
U
U
N
a
Installed
M
CL
02
°E
o
LL
V
Watts
J
Z
O
ED
p
LU
In
0
�_
V
j
N
O
J
O
o
r
z
J
w
Q
(Gxl)
H
Z
mIx
v
O
U
IL
=
E
z
z
0
�
�
r
Number
of
Luminaires
�
CEC
C=
Defaults
X
X
O
C)
Wafts
cj
per
((0
N
Luminaire
r
Number of
C�
O
LL
Ballast per
'r'-
CV
Luminaire
Watts
M
M
U)
w
per
N
Lamp
R
Number of
N
'q
m
0
Lamps per
N
CLE
Luminaire
t4
J
U
Lamp
Type
co
ccH
N
V_
U-
LL
c
�
d
U
U
_N
_N
Q
co
C
N
F
to
N
N
N
J
>
>
LL
LL
.v
v
N
�T
a�
E
M
Z
0
(O
(O
O
CD
0
N
0
rn
a
Q
m
U
U
N
a
w
CL
02
°E
o
LL
V
J
Z
O
ED
p
LU
In
0
�_
V
j
N
O
J
O
o
r
z
J
w
Q
H
Z
mIx
v
O
U
IL
=
E
z
z
0
r
m
0
IV
N N
o�
L:
E E
Z
C
,
ro
w
'c
C
3
0
o
O1
W
a
v
0
a
w
AIR SYSTEM REQUIREMENTS Part 1 of 2 MECH-2-C
f PROJECT NAME DATE
r1 Stamko Development T.I.-Dipping Dots 8/24/2006
SYSTEM FEATURES
ITEM OR SYSTEM TAG(S)
Number of Systems
T-24
MANDATORY MEASURES Section
Heating Equipment Efficiency
Cooling Equipment Efficiency
Heat Pump Thermostat
Furnace Controls
Natural Ventilation
Minimum Ventilation
VAV Minimum Position Control
Demand Control Ventilation
Time Control
Setback and Setup Control
Outdoor Damper Control
Isolation Zones
Pipe Insulation
• Duct Insulation
PRESCRIPTIVE MEASURES
Calculated Heating Capacity x 1.43 2
Proposed Heating Capacity 2
Calculated Sensible Cooling Capacity x 1.212
Proposed Sensible Cooling Capacity 2
Fan Control
DP Sensor Location
Supply Pressure Reset (DDC only)
Simultaneous Heat/Cool
Economizer
Heating Air Supply Reset
Cooling Air Supply Reset
Duct Sealing for Prescriptive Compliance
1: For each central and single zone air systems (or group of similar units) fill in the reference to sheet number and/or specification section and paragraph number where the
required features are documented. If a requirement is not applicable, put "N/A" in the column.
2: Not required for hydronic heating and cooling. Either enter a value here or put in reference of plans and specificatons per footnote 1.
3: Enter Yes if System is: Constant Volume, Single Zone; Serves < 5,000 sqft; Has > 25% duct in unconditioned space. Duct sealing is required for Prescriptive Compliance,
see PERF -1 for performance method duct sealing requirements.
AIR SYSTEMS, Central or Single Zone
HVAC -1
1
Reference on Plans or Specification 1
112(a)
7.20 HSPF
112(a)
12.0 SEER / 10.2 EER
112(b)
Yes
112(c), 115(a)
n/a
121(b)
Yes
121(b)
180 cfm
121 c
No
121(c)
No
121 c 122(e)
Programmable Switch
122(e)
Heating & Cooling Required
122
Auto
122()
n/a
123
124
R-4.2
144 a & b
n/a
144 a&b
0btuh
144 a & b
n/a
144 a & b
40,262 btuh
144 c
Constant Volume
144 (c)
144 c
Yes
144 d
No
144 a
No Economizer
144
Constant Tem
144(f)
Constant Temp
144 k)
No
Lug.a��►��rr��.a�•1u�11uu1!��a!r1l�rirarr�r��rr►.
EnergyPro 4.1 by EnergySoft User Number: 6712 Job Number: Paae:11 of 24 1
WATER SIDE SYSTEM REQUIREMENTS Part 2 of 2 MECH-2-C
PROJECT NAME DATE
Stamko Development T.I.-Dipping Dots 8/24/2006 71
SYSTEM FEATURES
2 WATER SIDE SYSTEMS: Chillers, Towers, Boilers, H dronic Loops
ITEM OR SYSTEM TAG(S)
Number of Systems
MANDATORY MEASURES
Equipment Efficiency
Pipe Insulation
PRESCRIPTIVE MEASURES
Calculated Capacity
Proposed Capacity
Tower Fan Controls
Tower Flow Controls
Variable Flow System Design
Chiller and Boiler Isolation
CHW and HHW Reset Controls
WLHP Isolation Valves
VSD on CHW, CW & WLHP Pumps > 5
HP
DP Sensor Location
T-24
Section Reference on Plans or Specification'
112(a)
123
144(a&b)
144(a&b)
144 h
144 h
144 0)
144
144 0)
144
144
144
•1: For each chiller, cooling tower, boiler, and hydronic loop (or groups of similar equipment) fill in the reference to sheet number and/or specification section and paragraph
number where the required features are documented. If a requirement is not applicable, put "N/A" in the column.
2: Water side systems include wet side system using other liquids such as glycol or brine.
ITEM OR SYSTEM TAG(S)
Number of Systems
MANDATORY MEASURES
Water Heater Certification
Water Heater Efficiency
Service Water Heating Installation
Pool and Spa Efficiency and Control
Pool and Spa Installation
Pool Heater - No Pilot Light
Spa Heater - No Pilot Light
113 (a)
113 b
113 (c)
114 a
114 b
115 (c)
115 d
Service Hot Water, Pool Heating
DHW Heater
1
AO SMITH ELJF-10
99%
n/a
n/a
n/a
n/a
Reference on Plans or Specification
1: For each water heater, pool heat and domestic water loop (or groups of similar equipment) fill in the reference to sheet number and/or specification section and
paragraph number where the required features are documented. If a requirement is not applicable, put "N/A" ins the column.
Run Initiation Time: 08/24/06 14:19:00 Run Code: 1156454340
EnergyPro 4.1 by EnergySoft User Number: 6712 Job Number: Page:12 of 24
U
M
No
►E,
0
O
N F
L
00 1
w L
a
o �
t
t
L
c
t
O
0
C
m
Q
_O
a)
N
0
Z
Transfer Air
N
0
Design Min. Ai
L
Setpoint
c
s"
Uv
m
a
u c
Max of
m
[
n
Columns H, J,
U t5
- cn
M
z
K or 300 CFM
a
Bx0.4
c
y
CO
—
>
a
Y
CFM/sq. ft.
m
>
LJ
r g
30% of Design
5
Zone Supply
3
CFM
m
Design
C)
$
H
O
m
—
Vent. Air
F
CFM
O
REQ'D V.A00
00_
O
�
i
=
Max of
y
m
g E
(D or G)
a 3
N
Min CFM
m
o
a
; 2
E
Fn
C7
by Occupant
v
n
m
(EXF)
o
2-=0
U
CFM
Z
LL
per
x
m E
Qa
Person
m
a m
s E
L)
U
m
io aci
E
t
Number of
O
W
People
O
a
o
`o o
E
Min CFM
00
N
c
y
N t
�
p
by Area04
(B X C)
m
Eo
N
N
N
N
o Z
m`
c
E
to
..
G
Q
CFM
N
o
T c
`o
¢ 0.
M
y
per
o
0.EE
;=
E
W
Square Foot
L g
:c o
z'
Q
Condition
`o m
d
>
m
Area
m
aj(SF)
a
an d
v
m
s >
d
U)
my
w
`
E
ym
-
m
m =
e
o E
m o
Z
`o
a o
x
mo
U
mm
O
m>
t=
0
Q
m
i
m
v S
U)
J
m
5
m
LL
c
i
x
o
Qn
I—
W
`o
a 0
E
ci
c
nm
i
Q
h
ii]
x
m 0
H
V
m
E m
a
r
J
Q
Z
w>�
c
c
m
m o
c E
?,
m
�.i
N
o
m n
_
c
o=
x
y
o
O
m
K
0
U
';
m
a
Q
z
M
IL-
V�
N
LO
c
W
WN
W
2-
-+
Y
2
Z
U)
_
17,
MECHANICAL EQUIPMENT DETAILS
Part 1 of 2 MECH-5-C
PROJECT NAME
Stamko Development T.I.-Dipping Dots
DATE $24/2006
CHILLER AND TOWER SUMMARY
Efficiency
Tons
PUMPS
Equipment Name
Equipment Type
Qty.
Tot.
Qty
GPM
BHP
Motor
Eff.
Drive
Eff.
Pump
Control
D / BOILER MM
Energy Standby ITANK INSUL.
Rated Vol. Condition Factor Loss or Ext.
System Name System Type Distribution Type Qty Input I (Gals.) Status or RE J Pilot I R -Val.
0 SMITH ELJF-10 Small Elec. Point of Use 1 5,120 10 New 0.95 n/a n/a
AM CENTRAL SYSTEM RATINGS
HEATING COOLING
Aux. Condition
System Name System Type Qtv —Output kW Eff. Out ut Efficiency Status Economizer Type
Carrier 50JX0605 Packaged DX 1 0 0.0 7.20 HSPF 60,000 12.0 SEER / 10.2 EER New No Economizer
r
ENVELOPE MANDATORY MEASURES ENV -MM
PROJECT NAME DATE
Stamko Development T.I.-Dippinq Dots I
8/24/2006
DESCRIPTION
Designer
Enforcement
❑ §118(,) Installed Insulating Material shall have been certified by the manufacturer to comply
". with the California Quality Standards for insulating material, Title 20, Chapter 4, Article
3.
X❑ § 118(c) All Insulating Materials shall be installed in compliance with the flame spread rating
and smoke density requirements of Sections 2602 and 707 of Title 24, Part 2.
FX]§ 117(a) All Exterior Joints and openings in the building that are observable sources of air
leakage shall be caulked, gasketed, weatherstripped or otherwise sealed.
❑ § 116(b) Site Constructed Doors, Windows and Skylights shall be caulked between the unit
and the building, and shall be weatherstripped (except for unframed glass doors and
fire doors).
X] § 116(a)1 Manufactured Doors and Windows installed shall have air infiltration rates not
exceeding those shown in Table Number 1-E. of the Standards. Manufactured
fenestration products must be labeled for U -value according to NFRC procedures.
X❑ §118(e) Demising Walls in Nonresidential Buildings:
The opaque portions of framed demising walls in nonresidential buildings shall have
Insulation with an installed R -value of no less than R-11 between framing members.
EnergyPro By EnergySoft User Number: User Job Number: Page: 15 of 24
A
B
C
D
E
F
Room
Name
Task/Activity
Description
Room
Length (L)
ft
Room
Width (WW)
ft
Room Cavity
Height (H)
(ft)
Room Cay. Ratio
5xHx(L+W)
/(LxW)
A
B
C
D
E
F
Room
Name
Task/Activity
Description
Room
Area (A)
(so
Room
Perimeter (P)
(ft)
Room Cavity
Height (H)
(ft)
Room Cay. Ratio
2.5 x H x P
/A
EnergyPro 4.1 by EnergySoft User Number: 6712 Job Number: Page:16 of 24 1
is
is
LIGHTING MANDATORY MEASURES LTG -MM
NAME DATE
Stamko Development T.I.-Dipping Dots 8/24/2006
DESCRIPTION
Designer
Enforcement
X❑ §131(d)1 For every floor, all interior lighting systems shall be equipped with a separate automatic
control to shut off the lighting. This automatic control shall meet the requirements of
Section 119 and may be an occupancy sensor, automatic time switch, or, other device
capable of automatically shutting off the lighting.
a §131(d)2Override for Building Lighting Shut-off: The automatic building shut-off system is
provided with a manual, accessible override switch in sight of the lights. The area
of override is not to exceed 5,000 square feet.
§119(h) Automatic Control Devices Certified: All automatic control devices specified are
certified, all alternate equipment shall be certified and installed as directed by the
manufacturer.
X❑ §111 Fluorescent Ballast and Luminaires Certified: All fluorescent fixtures specified for
the project are certified and listed in the Directory. All installed fixtures shall be
certified.
X] §132 Tandem Wiring for One and Three Lamp Fluorescent Fixtures: All one and three
lamp fluorescent fixtures are tandem wired with two lamp ballasts where required
by Standards Section 132; or all one and three lamp fluorescent fixtures are
I specified with electronic high -frequency ballasts and are exempt from tandem
wiring requirements.
X❑ §131(a) Individual Room/Area Controls: Each room and area in this building is equipped
with a separate switch or occupancy sensor device for each area with floor -to -
ceiling walls.
5131(b) Uniform Reduction for Individual Rooms: All rooms and areas greater than 100
square feet and more than 0.8 watts per square foot of lighting load shall be
controlled with bi-level switching for uniform reduction of lighting within the room.
§131(c) Daylight Area Control: All rooms with windows and skylights that are greater than
250 square feet and that allow for the effective use of daylight in the area shall
have 50% of the lamps in each daylit area controlled by a separate switch; or the
effective use of daylight cannot be accomplished because the windows are
continuously shaded by a building on the adjacent lot. Diagram of shading during
different times of the year is included on plans.
§131(e) Display Lighting. Display lighting shall be separately switched on circuits that
are 20 amps or less.
EnergyPro 4.1 by EnergySoft User Number: 6712 Job Number: Page: 17 of 24
is
MECHANICAL MANDATORY MEASURES Part 1 of 2 MECH-MM
NAME
Stamko DeveloDment T.I.-DiDDina Dots
DATE
8/24/2006
DESCRIPTION
Designer
Enforcement
Equipment and Systems Efficiencies
0 §111 Any appliance for which there is a California standard established in the
Appliance Efficiency Regulations will comply with the applicable standard.
§ 115(a) Fan type central furnaces shall not have a pilot light.
F§ 123 Piping, except that conveying fluids at temperatures between 60 and 105 degrees
Fahrenheit, or within HVAC equipment, shall be insulated in accordance with
Standards Section 123.
§ 124 Air handling duct systems shall be installed and insulated in compliance with
Sections 601, 603 and 604 of the Uniform Mechanical Code.
Controls
§ 122(e) Each space conditioning system shall be installed with one of the following:
FX] § 122(e)1A Each space conditioning system serving building types such as offices and
manufacturing facilities (and all others not explicitly exempt from the
requirements of Section 112 (d)) shall be installed with an automatic time switch
with an accessible manual override that allows operation of the system during
off -hours for up to 4 hours. The time switch shall be capable of programming
different schedules for weekdays and weekends and have program backup
capabilities that prevent the loss of the device's program and time setting for at
least 10 hours if power is interrupted; or
§ 122(e)1 B An occupancy sensor to control the operating period of the system; or
§ 122(e)1C A 4 -hour timer that can be manually operated to control the operating period of
the system.
§ 122(e)2 Each space conditioning system shall be installed with controls that temporarily
restart and temporarily operate the system as required to maintain a setback
heating and/or a setup cooling thermostat setpoint.
§ 122(g) Each space conditioning system serving multiple zones with a combined
conditioned floor area more than 25,000 square feet shall be provided with
isolation zones. Each zone: shall not exceed 25,000 square feet; shall be
provided with isolation devices, such as valves or dampers, that allow the supply
of heating or cooling to be setback or shut off independently of other isolation
areas; and shall be controlled by a time control device as described above.
® § 122(a&b) Each space conditioning system shall be controlled by an individual thermostat
that responds to temperature within the zone. Where used to control heating, the
control shall be adjustable down to 55 degrees F or lower. For cooling, the
control shall be adjustable up to 85 degrees F or higher. Where used for both
heating and cooling, the control shall be capable of providing a deadband of at
least 5 degrees F within which the supply of heating and cooling is shut off or
reduced to a minimum.
§ 122(c) Thermostats shall have numeric setpoints in degrees Fahrenheit (F) and
adjustable setpoint stops accessible only to authorized personnel.
§ 112(b) Heat pumps shall be installed with controls to prevent electric resistance
4
supplementary heater operation when the heating load can be met by the heat
pump alone.
EnergyPro By EnergySoft User Number: User Job Number: Page: 18 of 24
I __
MECHANICAL MANDATORY MEASURES Part 2 of 2 MECH-MM
NAME DATE
Stamko Development T.I.-Dipping Dots 8/24/2006
Description
Designer
Enforcement
Ventilation
❑X § 121(e) controls shall be provided to allow outside air dampers or devices to be operated at
the ventilation rates as specified on these plans.
X] § 122(f) Gravity or automatic dampers interlocked and closed on fan shutdown shall be
provided on the outside air intakes and discharges of all space conditioning and
exhaust systems.
§ 1440 All gravity ventilating systems shall be provided with automatic or readily accessible
manually operated dampers in all openings to the outside, except for combustion air
openings.
R§ 121(f)1 Air Balancing: The system shall be balanced in accordance with the National
Environmental Balancing Bureau (NEBB) Procedural Standards (1983), or
Associated Air Balance Council (AABC) National Standards (1989); or
❑ § 121(f)2 Outside Air Certification: The system shall provide the minimum outside air as
shown on the mechanical drawings, and shall be measured and certified by the
Installing licensed C-20 mechanical contractor and certified by (1) the design
mechanical engineer, (2) the installing licenced C-20 mechanical contractor, or (3) the
person with overall responsibility for the design of the ventilation system; or
X❑ § 121(f)3 Outside Air Measurement: The system shall be equipped with a calibrated local or
remote device capable of measuring the quantity of outside air on a continuous
basis and displaying that quantity on a readily accessible display divice; or
X❑ § 121(f)4 Another method approved by the Commission.
Service Water Heating Systems
R§ 113(b)2 If a circulating hot water system is installed, it shall have a control capable of
automatically turning off the circulating pump(s) when hot water is not required.
X❑ § 113(b)3B Lavatories in restrooms of public facilities shall be equipped with controls to limit the
outlet temperature to 110 degrees F.
RX § 113(b)3C Lavatories in restrooms of public facilities shall be equipped with one of the
following:
Outlet devices that limit the flow of hot water to a maximum of 0.5 gallons per
minute.
Foot actuated control valves, and outlet devices that limit the flow of hot water to a
maximum of 0.75 gallons per minute.
Proximity sensor actuated control valves, and outlet devices that limit the flow of hot
water to a maximum of 0.75 gallons per minute.
Self-closing valves, and outlet devices that limit the flow of hot water to a maximum
of 2.5 gallons per minute, and 0.25 gallons/cycle (circulating system).
Self-closing valves, and outlet devices that limit the flow of hot water to a maximum
of 2.5 gallons per minute, and 0.50 gallons/cycle (non -circulating system).
Self-closing valves, and outlet devices that limit the flow of hot water to a maximum
of 2.5 gallons per minute, and 0.75 gallons/cycle (foot switches and proximity sensor
controls).
EnergyPro By EnergySoft User Number: User Job Number: Page:19 of 24
HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY
PROJECT NAME DATE
Stamko Development T.I.-Dipping Dots 8/24/2006
SYSTEM NAME FLOOR AREA
HVAC -1 900
Number of Systems
1
Heating System
Output per System
0
Total Output (Btuh)
0
Output (Btuh/sqft)
0.0
Cooling System
Output per System
60,000
Total Output (Btuh)
60,000
Total Output (Tons)
5.0
Total Output (Btuh/sgft)
66.7
Total Output (sgft/Ton)
180.0
Air System
CFM per System
2,000
Airflow (cfm)
2,000
Airflow (cfm/sqft)
2.22
Airflow (cfm/Ton)
400.0
Outside Air (%)
9.0
Outside Air (cfm/sgft)
0.20
Note: values above given at ARI conditions
Total Room Loads
Return Vented Lighting
Return Air Ducts
Return Fan
Ventilation
Supply Fan
Supply Air Ducts
TOTAL SYSTEM LOAD
COIL COOLING PEAK
COIL HTG. PEAK
CFM
ISensible
Latent
CFM
I Sensible
1,945
29,353
4,390
495
20,804
0
1,468
1,040
0
0
180
7,147
2,010
180
8,335
0
0
1,4681
1,040
39143:5[=6 400 31 220
Carrier 50JX0605 40,262 13,673 0
Total Adjusted System Output 40,262 13,673
(Adjusted for Peak Design Conditions)
01
TIME OF SYSTEM PEAK Jul 3 pm Jan 12 am
EATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak
26.0 OF 65.6 OF 110.0 °F 110.0 OF
Supply Air Ducts
Outside Air
180 cfm 109.5 °F
Heating Coil Supply Fan
2000 cfm ROOMS
69.5 OF 70.0 OF
Return Air Ducts I
1000LING SYSTEM PSYCHROMETRICS (Airstream Temperatures at Time of Coolina Peakl
112.0 / 77.9 OF 78.0 / 65.7 OF 0 59.1 / 58.1 OF
Outside Air
180 cfm
Cooling Coil
74.7/64.3 °F
0
Supply Fan
2000 cfm
59.1 / 58.1 OF
-� Supply Air Ducts
59.8 / 58.4 OF
58.7% R.H. ROOMS
74.0 / 64.0 OF
h Return Air Ducts \1
EnergyPro 4.1 by Energysoft User Number: 6712 Job Number: Page: 20 of 24
ROOM LOAD SUMMARY
EnergyPro By EnergySoft User Number: User Job Number: Page:21 of 24
PROJECT NAME
Stamko Development T.I.-Dipping Dots
DATE
8/24/2006
7
SYSTEM NAME
HVAC -1
FLOOR AREA
900
ROOM LOAD SUMMARY
ROOM COOLING PEAK
COIL COOLING PEAK
COIL HTG. PEAK
ZONE NAME
ROOM NAME
Mult.
CFM
SENSIBLE
LATENT
CFM
SENSIBLE
LATENT
CFM
SENSIBLE
Suite 5
Suite 5
1
1,945
29,353
4,390
1,945
29,353
4,390
495
20,804
' PAGE TOTAL 1,945 29,353 4,390F 495 20,804
TOTAL 1 1,9451 29,353 4,390 495 20,804
EnergyPro By EnergySoft User Number: User Job Number: Page:21 of 24
ROOM HEATING PEAK LOADS
ct Title
mkn nPvPlnnmPnt Ti -ninninn fonts
a/9nnF
Room Information Desi n Conditions
Room Name suite 5
Time of Peak Jan 12 am
Floor Area 900
Outdoor Dry Bulb Temperature 26OF
Indoor Dry Bulb Temperature 70 OF
X
x
X
X
X
X
X
X
X
X
x
X
X
X
X
X
X
X
X
X
X
x
X
x
X
X
X
X
X
x
X
X
X
x
X
X
X
X
X
X
Conduction Area H -value AT oI= Rtri/hr
•
R-30 Roof R.30.2x10.24
surface
Area
900.0
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
x
X
X
X
X
X
X
X
X
X
x
X
X
X
X
X
X
0.0340
X
x
X
X
X
X
X
X
X
X
x
X
X
X
X
X
X
X
X
X
X
x
X
x
X
X
X
X
X
x
X
X
X
x
X
X
X
X
X
X
44
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
1,346
R-19 Wall .19.24.16
120.0
0.0740
44
391
Double Metal Tent
30.0
0.7200
44
950
Double Metal Tint
24.0
0.7200
44
760
6.0
0.7200
44
190
R-11 Partition Wall .11.2x4 16
720.0
0.1100
44
3,485
R-19Wall (W.19,24,16)
159.0
0.0740
44
518
Metal Door
21.0
0.7000
44
647
R-1 1 Parfitaon Wall ON 11 Px4 1 F;)
720.0
0,1100
44
3,485
Slab -On -Grade
perimeter= 150.0
0.7300
4,818
Items shown with an asterisk (`) denote conduction through an interior
Infiltration: r 1.001 X 1.064 X
schedule Air Sensible
Fraction
to another room.
900 X 12.00
Ceiling Height
0.500 / 6 ]
ACH
Page Total:
®
OT
16 590
4 214
TOTAL HOURLY HEAT LOSS FOR ROOM 20,804
EnergyPro 4.1 by EnergySoft User Number: 6712 Job Number: Page: 22 of 24
ROOM COOLING PEAK LOADS
Project Title Date
Stamko Development T.I.-Dipping Dots 8/24/2006
ROOM INFORMATION DESIGN CONDITIONS
Room Name Suite 5 Time of Peak Jul 3 pm
Floor Area 900 Outdoor Dry Bulb Temperature 112 OF
Indoor Dry Bulb Temperature 74`F Outdoor Wet Bulb Temperature 78 OF
Conduction
-30 Roof R.30.2x10.24
-19 Wall W.19.2x6.16
Double Metal Tint
Double Metal Tint
-11 Partition Wall W.11.2x4.16
-19 Wall .19.2x6.16
Metal Door
-11 Partition Wall W.11.2x4.16
Area
1 900.01
21.0
1. Design Equivalent Temperature Difference (DETD)
Items shown with an asterisk (') denote conduction through an interior surface to another room.
Solar Gain
U -Value
X
0.0340
X
0.0740
X
0.7200
X
0.7200
X
0.1100
X
0.0740
X
0.7000
X
0.1100'
X
0:832
DETD 1
X
X
X
X
X
X
X
X
X
72.5
=
=
=
=
=
=
=
=
=
56.8
27.1
27.1
39.5
45.6
39.1
57.6
30.0
Page Total
Orientation
Area
X
X
X
X
x
X
X
X
X
x
SGF
X
X
X
X
X
x
X
X
X
X
SC
Weighting
X
X
X
X
X
X
X
X
X
X
Factor
=
=
=
=
=
=
=
=
=
U
30.0
41
0.657
0.832
(N)
24.0
41
0.657
0:832
(N)
6.0
41
0.657
0.832
Page Total
Btu/hr
2,218
504
586
586
3,126
537
575
4,560
12 691
Btu/hr
672
538
134
1 344
Sched. Weighting Btu/hr
Internal Gain Frac. Area Heat Gain Factor
i hts 1.0 X 900 X 1.584 Watts/sqft X 3.41 Btuh/Watt x 0.999 = 4,862
ccu ants 1.0 X 900 x 300 Btuh/OCC. / 10 sgft/OCc. x 1.00 = 2,700
Receptacle 11.0c X 900 x 1.340 Watts/sgft x 3.41 Btuh/Watt x 1.00 = 4,116
rocess 1.0 x 900 x 0.000 Watts/sgft x 3.41 Btuh/Watt x 1.00 = 0
Infiltration: 1.00 X 1.064 X 900 X 12.00 X 0.50 / 6] X 38 = 3 640
Schedule Air Sensible Area Ceiling Height ACH &T
Fraction
TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 29,353
Sched.
Latent Gain Frac. Area Heat Gain Btu/hr
Occupants 1.00 X 900 x 3001 Btuh/OCC. / 100 sgftlocc. = 2 700
Receptacle 1.00 x x a on Watts/sgft x 3 4131 Btuh/Watt =
Process 1.00 x soo x 0.000 Watts/sgft x 3.4131 Btuh/Watt = o
Infiltration: x 4 771 x x x / 60] x_
chedule Air Latent Area Ceiling Height ACH pyy
TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 437901
EnergyPro By EnergySoft User Number: User Page:23 of 24
ROOM COOLING COIL LOADS
Project Title Date
Stamko Development T.I.-Dipping Dots 8/24/2006
ROOM INFORMATION DESIGN CONDITIONS
Room Name Suite 5 Time of Peak Jul 3 pm
Floor Area 900 Outdoor Dry Bulb Temperature 112 9F
Indoor Dry Bulb Temperature 74`F Outdoor Wet Bulb Temperature 78 OF
Conduction
-30 Roof (R.30.2x10.24
19 Wall W.19.2x6.16
Double Metal Tint
Double Metal Tint
-11 Partition Wall .11.2x4.16
-19 Wall W.19.24.16
Metal Door
-11 Partition Wall W.11.2x4.16
Area
1 120.01
21
1. Design Equivalent Temperature Difference (DETD)
Items shown with an asterisk (') denote conduction through an interior surface to another room.
Solar Gain
U -Value
X
0.0340
X
0.0740
X
0.7200
X
0.7200
X
0.1100
X
0.0740
X
0.7000
X
0.1100
X
0.832
DETD 1
X
X
X
X
X
X
X
X
X
72.5
=
=
=
=
=
=
=
=
=
56.8
27.1
27.1
39.5
45.6
39.1
57.6
30.0
Page Total
Orientation
Area
X
X
X
X
X
X
x
X
X
X
SGF
x
X
X
x
x
X
X
X
X
X
Sc
Weighting
X
X
X
X
x
x
X
X
X
x
Factor
=
=
=
=
=
=
=
=
=
(N)
30.0
41
0.657
0.832
(N)
24.0
41
0.657
0.832
(N)
6.0
41
0.657
0.832
Page Total
Btu/hr
2,218
504
586
586
3,126
537
575
4.560
12 691
Btu/hr
672
538
134
1344
Sched. Weighting
Internal Gain Frac. Area Heat Gain Factor Btu/hr
i hts 1.0 x 900 X 1.584 Watts/sqft x 3.41 Btuh/Watt X 0.999 = 4,862
ccu ants 1.0 x 900 x 300 Btuh/occ. / 10 sqft/occ. X 1.00 = 2,700
Receptacle 1.0 x 900 X 1.340 Watts/sgft x 3.41 Btuh/Watt X 1.00 = 4,116
rocess 1.0c x 900 x 0.000 Watts/sqft x 3.41 Btuh/Watt x 1.00 = 0
Infiltration: 1.00 x 1.064 x 900 x 12.00 x 0.50 / 60] x 38 = 1 3,6401
-Schedule Air Sensible Area Ceiling Height ACH Z�,T
Fraction
TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 29,353
Sched. Btu/hr
Latent Gain Frac. Area Heat Gain
Occupants 1.00 x 900 x 3001 Btuh/OCC. / 100 sgft/occ. = 2 700
Receptacle 1.00 x x 0 000 Watts/sgft x i 41a I Btuh/Watt =
Process 1.00 x 900 X 0.000 Watts/sqft x 3.413 Btuh[Watt = o
• Infiltration: x x x Ceiling Height x ACH � / 6] x _ 1 1'640J
chedule Air Latent Area pyy
TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 4 390
EnergyPro By EnergySoft User Number: User Page:24 of 24