05-0332 (RC)
BUILDING & SAFETY DEPARTMENT w4 P.O. Box 1504 (760),777-7012 ti9 78-495 CALLE TAMPICO FAX (760) 777-7011 LA QUINTA, CALIFORNIA 92253 •INSPECTION. REQUESTS (760) 777-7153 BUILDING PERMIT Application Number . . . .05-00000332, _..___._. Date 4/08/05 Property Address . . . . . .'-'79400 HIGHWAY_111._#10 APN: ' 649-820-002- - - Application description . . . REMODEL - COMMERCIAL Property Zoning . . . . . . . REGIONAL COMMERCIAL Application valuation . . . . 53000 Owner Contractor ti , - KLEINE NEIL WAYNE REIMER CONSTRUCTION CORP 41910 BOARDWALK A-10 69130 SAN HELENA AVENUE PALM DESERT CATHEDRAL CITY CA 92234 PALM DESERT CA 92211 (760) 328-4123 WCC: STATE FUND WC: 0482934 03/16/06 CSLB: 415901 12/31/05 CCC: B -C17 -------------------------- Structure Information ------------------------- Construction Type . . . . . TYPEtV - NON RATED Occupancy Type . . . . . . MERCANTILE•' Flood Zone . . . . . . . . NON -AO FLOOD ZONE Other struct info . . . . . CODE EDITION 2001 FIRE SPRINKLERS YES OCCUPANT LOAD 107.00 1ST FLOOR SQUARE FOOTAGE -.,'3.222.00 ----------------*--------------------'---------------------------------------- Permit . . . . . . BUILDING PERMIT Additional desc Permit Fee 428.00• Plan Check Fee .'. 278.20 Issue Date . . . . Valuation . . . . 53000 Qty Unit Charge Per Extension BASE FEE 414.50 3.00 4.5000 ---------------------------------------------------------------------------- THOU BLDG 50,001-100,000 13.50 Permit . . . . . . ELECT - ADD/ALT/REM Additional desc Permit Fee . . . . 79.44' Plan Check Fee 19.86 Issue Date . . . . Valuation . . . . 0 Qty Unit Charge Per Extension BASE FEE 15.00 3222.00 .0200 -------------------------------- ELEC GARAGE OR NON-RESIDENTIAL 64.44 . . . . . . '`MECHANICAL : Additional desc Permit Fee . . . . 51.00 Plan Check Fee 12.75 P.O. BOX 1504 • n/ VOICE (760) 777-7012 78-495 CALLS TAMPICO FAX (760) 777-7011 LA QUINTA, CALIFORNIA 92253 INSPECTIONS (760) 777-7153 BUILDING & SAFETY DEPARTMENT Application Number: e9 33 2 I Date: --0 so, Applicant: �Jzz�� Applicant's Mailing Address: Architect or Engineer: Architect or Engineer's Address: Lic. No.: BUILDING PERMIT DECLARATIONS LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that 1 am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professionals Code, and my Licentis in full force and effect. �1 License Class f S L_icpnsP Nn Tf S 5 D OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractors' State License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractors' State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).): U I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself or through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). U I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). U I am exempt under Sec. , B.& P.C. for this reason i Date << S Owner WORKERS' COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. _ I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My work rs' compensation insurance carrier and policy number re: Carrier STR ! 4eylm Policy Number d 4" S�iye" I certify that, in the performance of the work for which this permit is issue I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, if I should become subject to the workers' compensation provisions of Section 3700 of the Labor Code, 1 shall forthwith comply with those provisions. Date Z/< O WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000), IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Name Lender's Address APPLICANT ACKNOWLEDGEMENT IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the conditions and restrictions set forth on this application. 1. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application, the owner, and the applicant, each agrees to, and shall, defend, indemnify and hold harmless the City of La Ouinta, its officers, agents and employeesfor any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subje it to cancellation. I certify that I have read this application and state -Mat the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building const tion, and hereby authorize represe Ives of this county to enter upon the above -menti ned property for inspection purposes. Date B S Sig ure (Applicant or Agent): i Y r 0 Page 2 Application Number . . . . . 05-00000332 Date 4/08/05 Issue Date Valuation . . . . 0 Qty Unit Charge Per Extension BASE FEE 15.00 2.00 9.0000 EA MECH FURNACE <=100K 18.00 2.00 9.0000 EA MECH B/C <=3HP/100K BTU ---------------------------------------------------------------------------- 18.00 Special Notes and Comments COMMERCIAL INTERIOR TENANT IMPROVEMENT - 3,222 SQ.FT. SUITES 102 & 103. "PREMIER BILLIARDS" "M" OCCUPANCY, TYPE V -N CONSTRUCTION, 107 OCCUPANT LOAD, 2001 CODES. ---------------------------------------------------------------------------- Other Fees . . . . . . . . . ACCESSIBILITY PLAN REVIEW 27.82 ENERGY REVIEW FEE 27.82 STRONG MOTION (SMI) - COM 11.13 Fee summary Charged Paid Credited ----------------- Due ------------------------------ Permit Fee Total 558.44 .00 ---------- .00 558.44 Plan Check Total 310.81 .00 .00 310.81 Other Fee Total 66.77 .00 .00 66.77 Grand Total 936.02 .00 .00 936.02 0 0 1 Tlit(f 4 4QUM& P.O., BOX 1504 BUILDING & SAFETY DEPARTMENT 78-495 CALLE TAMPICO (760) 777-7012 LA QUINTA, CALIFORNIA 92253 FAX (760) 777-7011 To: Greg Butler, Building & Safety Manager To CDD: _02/01/05_ From: Oscar Orci, Planning Manager Due date: 02/13/05_ Status: IT Review Building Plans Approval (This is an approval to issue a building permit) The Community Development Department has reviewed the Building Plans for the following project: Description: TENANT IMPROVEMENTS Address or general location: 79-400 HWY 111 #102 (TI) Applicant Contact: _JOHN BART 776-9172 The Community Development Department finds that: ❑ ...these Building Plans do not require Community Development Department approval. ... these Building Plans are approved by the Community Development \ Department. ❑ ... these Building Plans require corrections. Please forward a copy of the attached corrections to the applicant. When the corrections are made please return them to the Community Development Department for review. Doug Evans, Planning. Director Date YO UNG ENGINEERING SERVICES •Engineering *Architecture•Surveying• Building & Safety Services Letter of Transmittal To: City of U Quinta Attn: Ed Randall Tel No.: (760) 777-7012 We are forwarding: No. of Copies 1 .1 1 ' 1 X By Messenger Description: Sets of redlined plans Date: 4/7/05 Project: 79-400 Hwy 111 Suite 102 PC#: PC# 05-0332 (2nd Check) Tract No.: Set of revised plans Structural calculation packet Architectural response list Comments: Structural contents are approvable. Thanks This Material Sent for: Your Files Your Review Checking Other By: Eric Frenzel Phone # 760-360-5770 By Mail Your Pickup Per Your Request x Approval At the request of: 77-804 Wildcat Drive, Suite C, Palm Desert, CA 92211 (760) 360-5770 Bronz Young Cf. Craig E. Anthony Fire Chief Proudly serving the unincorporated areas of Riverside County and the Cities of: Banning 4. Beaumont Calimesa 4. Canyon Lake Coachella le Desert Hot Springs Indian Wells Indio Lake Elsinore 4. La Quinta 4. Moreno Valley Palm Desert Perris Rancho Mirage San Jacinto 4. Temecula Board of Supervisors Bob Buster, District 1 John Tavaglione, District 2 Jeff Stone, District 3 Roy Wilson, District 4 Marion Ashley, District 5 RIVERSIDE COUNTY FIRE DEPARTMENT Highway lo, Fax (160) 863-7012 March 29, 2005 Robert Pitchford Architect 74-835 Fox Hils Ct. Palm Desert, CA 92260 Re: Non -Structural Building T/I Plan Review LAQ-05-TI-032 / Premier Billiards & Design 79-400 Hwy 111, Ste. 102 Fire Department personnel have reviewed and approved the plans you submitted for the above referenced project. Please be advised the following conditions apply as a part of the conditions for the issuance of a building permit. i. 1) As may be necessary to maintain proper fire sprinkler protection due to constructions changes, fire sprinkler system plans for the tenant improvement area may be required to be submitted to the Fire Department for review, along with a plan/inspection fee. The approved plans, with Fire Department Job card must be at the job site for all inspections. 2) Provide keys to the tenant space for inclusion in the main building Knox Box. Key(s) shall have a durable and legible tag affixed for identification of the correlating tenant space. 3) Install portable fire extinguishers per Title 19, but not less than 2A1 OBC in rating. Contact certified extinguisher company for proper placement of equipment. 4) Approved building address shall be placed in such a position as to be plainly visible and legible from the street and rear access if applicable. In multi -tenant buildings, businesses shall post the business name and suite number on back doors as well as the front. Suite numbers or letters must be a minimum of 6" in height. All addressing must be legible and of a contrasting color with the background. Please contact the Fire Department Planning & Engineering staff for final inspection prior to occupancy. Requests for inspections are to be made at least 72 hours in advance and may be arranged by calling (760) 863-8886. All questions regarding the meaning of these conditions should be referred to the Fire Department Planning & Engineering staff at (760) 863-8886. I/Cc: City of La Quinta - Building Dept:, WMW nava Q*ft%PR0AECMThL4Q4&Tt-M.d= Sincerely, FRANK KAWASAKI Chief Fire Department Planner By �FJL Walter Brandes Fire Safety Specialist EMERGENCY SERVICES DIVISION • PLANNING SECTION • INDIO OFFICE 82-675 Highway 111, 2- FI., Indio, CA 92201 • (760) 863.8886 • Fax (760) 863-7072 I - . TITLE 24 REPORT Title 24 Report for: Premier Billards &_ Design --�403 400High aw y 111, Suites102 & La Quinta, Ca -92253 Project Designer: Stein Trending Branding Design, LLC. 430 First Avenue North, Suite 640 Minneapolis, MN 55401 (612) 338-3339 Report Prepared By: Tim Scott H & H Air Conditioning 74-991 Joni Drive #20 Palm Desert, CA 92260-2043 (760) 340-3088 CITY OF LA QUINTA BUILDING & SAFETY DEpr. APPROVED FOR CONSTRUCTION Job Number: copes OA 3 3/ DS8Y _ 05 = Date: 1/7/05 The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has kpproval and is i authorized by the California Energy Commission for use with both the Residential and Nonresidential 2001 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC (415) 883-5900. EnergyPro 3.1 By EnergySoft Job Number: User Number: 5533 _ j II TABLE OF CONTENTS I Cover Page 1 . Table of Contents 2 Nonresidential Performance Title 24 Forms 3 Form LTG -4 Tailored LPD Summary and Worksheet 8 Form LTG -5 Room Cavity Ratio Worksheet 9 Form LTG -MM Lighting Mandatory Measures 10 MECH-3 Mechanical Ventilation 11 M EnergyPro 3.1 By EnergySoft Job Number: i User Number: 5533 PERFORMANCE CERTIFICATE OF COMPLIANCE Part 1 of 3 PERF -1 PROJECT NAME DATE Premier Billards & Design 1/7/05 PROJECT ADDRESS 79400 Highway 111, Suites 102&103 La Quinta PRINCIPAL DESIGNER-ENVEL6P TELEPHONE Building Permit # Stein Trending Branding Design, LLC. (612) 338-3339 DOCUMENTATION AUTHOR TELEPHONE Checked by/Date H & H Air Conditioning (760) 340-3088 Enforcement Agency Use EnergyPro 3.1 By EnergySoft User Number: 5533 Job Number: Page:3 of 11 Certificate of Compliance lists the building features and performance specifications needed to comply with Title 24, Parts 1 and IThis 6, of the State Building Code. This certificate applies only to a Buildi g using the performance compliance approach. DOCUMENTATION AUTHOR SIGTTAT DA E Tim Scott 1 7�p y The Principal Designers hereby certify that the proposed building design represented in the construction documents an mo elled for this permit application are consistent with all other forms and worksheets, specifications, and other calculations submitted with this permit application. The proposed building as designed meets the energy efficiency requirements of the State Building Code, Title 3,222 Sq.Ft. ENV. LTG. MECH. 15 BUILDING TYPE NONRESIDENTIAL mechanical engineer, electrical engineer or architect. i HIGH RISE RESIDENTIAL E] HOTEL/MOTEL GUEST ROOM PHASE OF CONSTRUCTION NEW CONSTRUCTION Code Sections 5537, 5538, and 6737.1. (These sections of the Business and Professions Code ae printed in full in the Nonresidential Manual.) ADDITION [:] ALTERATION F-� EXISTING + ADDITION I EnergyPro 3.1 By EnergySoft User Number: 5533 Job Number: Page:3 of 11 Certificate of Compliance lists the building features and performance specifications needed to comply with Title 24, Parts 1 and IThis 6, of the State Building Code. This certificate applies only to a Buildi g using the performance compliance approach. DOCUMENTATION AUTHOR SIGTTAT DA E Tim Scott 1 7�p y The Principal Designers hereby certify that the proposed building design represented in the construction documents an mo elled for this permit application are consistent with all other forms and worksheets, specifications, and other calculations submitted with this permit application. The proposed building as designed meets the energy efficiency requirements of the State Building Code, Title 24, Part 6. ENV. LTG. MECH. R n 1. 1 hereby affirm that I am eligible under the provisions of Division 3 of the Business and Professions Code to sign this document as the person responsible for its preparation; and that I am licensed as a civil engineer, mechanical engineer, electrical engineer or architect. i Fi o 2. 1 affirm that I am eligible under the provisions of Division 3 of the Business and Professions Code Section ; 5537.2 or 6737.3 to sign this document as the person responsible for its preparation; and that I am a licensed contractor preparing documents for work that I have contracted to perform. 0 3. 1 affirm that I am eligible under Division 3 of the Business and Professions Code to sign this document because it pertains to a structure or type of work described as exempt pusuant to Business and Professions Code Sections 5537, 5538, and 6737.1. (These sections of the Business and Professions Code ae printed in full in the Nonresidential Manual.) Indicate location on plans of Note Block for Mandatory Measures Required Forms Envelope Compliance Not In The Scope Of TITIS Submittal PRINCIPALENVECOPE-DESTGNER - NAM SIGN-ATUR C -PTO. ATE— ILIGHTING COMPLIANCE Indicate location on plans of Note Block for Mandatory Measures i Required F rms LTG -1 � 2 DESIA GNER -1NA y PR,INCWAAIGH75 SIGN"E LIC. NO. DACE —I a Indicate location on plans of Note Block for Mandatory Measures Mechanical Compliance Not In the Scope Required Forms This SUbmlttal - ^--- PRINCIPAL MECHANICAL DESIGNER - NAME SIGNATURE LIC. NO. DATE EnergyPro 3.1 By EnergySoft User Number: 5533 Job Number: Page:3 of 11 PERFORMANCE CERTIFICATE OF COMPLIANCE Part 2 of 3 PERF -1 DATE Premier Billards & Design 1/7/05 u sq -yr ENERGY COMPONENT Standard Design Proposed Design Compliance Margin ItiStandard _, ,,. 'Froposee Space Heating Space Cooling Indoor Fans Heat Rejection Pumps & Misc. Domestic Hot Water Lighting Receptacle Process TOTALS: 1.40 1.58 -0.19°"x° "� t SpBGeOoo'I d°�= 63.04 59.68 3.35 19.37 18.53 0.84 0.00 0.00 0.00 0.00 0.00 0.00x`; 0.00 0.00 0.00F�.;: 50.09 40.41 9.68'0"�0�` 15.92 15.92 0.00R"r 149.81 136.13 13.69 kBkdsqh-Y` GENERAL INFORMATION Building Orientation Number of Stories Number of Systems Number of Zones (South) 180 deg Conditioned Floor Area 3,222 sqft. 1 Unconditioned Floor Area o sqft. 2 Conditioned Footprint Area 3,222 sqft. 1 Orientation Front Elevation (South) Left Elevation (west) Rear Elevation (North) ti Right Elevation (East)l Total Roof Gross Area sqft. sqft. sqft. sqft. sqft. sqft. Glazing Area Glazing sqft. sqft. sqft. sqft. sqft. sqft. Ratio 1,180 120 10.2% 0 0 0.0% 1,180 98 8.3% 0 0.0% 2,360 218 9.20/6 3,222 =::::� 0.0% Standard Proposed Lighting Power Density 1.700 wisgft. 1.371 wisgft. Prescriptive Env. Heat Loss 623 513 Prescriptive Env. Heat Gain 62,997 50,825 emar s: Run InitiationTime: un Code: 1105133056 EnergyPro 3.1 By EnergySoft User Number: 5533 Job Number: Page:4 of 11 PERFORMANCE CERTIFICATE OF COMPLIANCE Part 3 of 3 PERF -1 PROJECT NAME Premier Billards & Design DATE 1/7/05 System Name Zone Name Floor Area Occupancy Type (sqft.) Inst. LPD (W/sf)1 Port. Ctrl .at ore LPD Credits (W/sf)1 (W/sf)2 (W/S03 Proc. Loads (W/sf) HVAC -5 Premier Billards Comp Bldg Retail/Wholesale 3,222 1.371 0.000 Notes: 1. See LTG -1 (items marked with asterisk, see LTG -2 by others) 2. See LTG -3 3. See LTG -4 Items above require special documentation i ne local enforcement agency snoula pay special attention to the items specitiea in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The local enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted. Plan Field The Zone "Premier Billards" has a Display Perimeter Credit of 213 ft. The exceptional features listed in this performance approach application have specifically been reviewed. Adequate written justification and documentation for their use have been provided by the applicant. Authorized Signature or Stamp I•cun initiation I lme: U1/U1/U5 13:24:16 Run Code: 1105133056 EnergyPro 3.1 By EnergySoft User Number: 5533 Job Number: Page:5 of 11 LIGHTING COMPLIANCE SUMMARY Part 1 of 2 LTG -1 Premier Billards & Design I 1/7/05 LAMPS BALLASTS afire Code LUMINAIRE DESCRIPTION TYPE DESCRIPTION# Use Unly Watts er Lamp DESCRIPTION # tLdmp T odnds FTotal Watts # Watts A (2) 4 ft Fluorescent T12 ES F40T12/ES 2 34 Magnetic Standard 1.0 30 82.0 2,460 J LV Track Light 25w per Foot Track Lights 1 25 No Ballast 12 25.0 300 K (1) 26w Compact Fluorescent Quad 2 Pin CFQ26W/G24d-3 1 26 Magnetic Standard 1.01 31 37.0 111 L (1) 4 ft Fluorescent T8 Elec F32TB 1 32 Electronic 1.0 10 32.01 320 M LV Track Light 25w per Foot Track Lights 1 25 No Ballast 49 25.0 1,225 4,416 Lighting Schedule on Plans Shows Exterior Lighting Subtotal from this Page Meets Total 4,416 �0 Efficacy and Control Requirement of§130(c) Portable Lighting (From LTG -1) Less Control Credit Watts (From LTG -3) Control Requirements ofg131(f) 4,416 Adjusted Actual Watts CONTROL LOCATION I CONTROL CONTROL TYPE I LUMINAIRES CONTROLLED (Room # or Dwg. #) IDENTIFICATION (Occupant, Daylight, Dimming, etc.) I I YI-j # OF LU1AIRAIR1 NOTE TO FIELD NOTE TO FIELD - or building Department Use Unly Run Initiation Time: 0 un Code: 1105133056 EnergyPro 3.1 By EnergySoft User Number: 5533 Job Number: Page:6 of 11 LIGHTING COMPLIANCE SUMMARY Part 2 of 2 LTG -1 Premier Billards & Design 1 1/7/05 FA] a o u 0 OR ZONE ID (W/sgft) (SF) (B X C) TOTAL 0 0 F o a a o a a LUMIN. TASK # OF TOTAL TOTAL ROOM # PORTABLE LIGHTING # OF WATTS PER AREA TASK AREA (SF) WATTS OR ZONE ID Description FIXT. FIXTURE (SF) AREAS (D x E) (C x E) ROOM # TOTAL AREA OR ZONE ID (SF) TOTAL 0 Designer needs to provide detailed documentation that the lighti level provided by the overhead lighting meets the needs of the space. The details include luminaire types, CU, and mounting locations relative to work areas. BUILDING SUMMARY TOTAL AREA (SF � (FROM TABLES 1A+1 +1C) TOTAL WATTS (FROM TABLES 1A+1B) BUILDING TOTAL 3,222 0 Run Initiation Time: 01107105 13:24:16un Code: 1105133056 EnergyPro 3.1 By EnergySoft User Number: 5533 Job Number: Page:7 of 11 TAILORED LPD SUMMARY and WORKSHEET Part 1 of 3 LTG -4 Premier Billards & Design 117/05 1. Watts for Illuminance Categories A -D (from column G) — 01 watts 2. Watts for Illuminance Categories E-1 (from LTG -4 Part 2) 0 watts 3. Watts for Display Lighting (from LTG -4 Parts 2 & 3) + 1 01+ 0 = 0 watts Public Area Display Sales Feature Floor Display Sales Feature Wall Display 4. Total Allowed Watts (lines 1+2+3) > 0 watts uminance Categories , ancl u and Gross Sales Area FA a a o o n a ROOM NAME TASK/ACTIVITY ILLUMINANCE CATEGORY ROOM CAVITY RATIO FLOOR AREA ALLOWED LPD ALLOWED WATTS (E x F) Premier Billards & Design A 1.01 0 0.20 0 PAGE TOTAL 01 BUILDING TOTAL 3,22201 SF WATTS EnergyPro 3.1 By EnergySoft User Number: 5533 Job Number: Page:8 of 11 ROOM CAVITY RATIO WORKSHEET (RCR>=3.5) LTG-5 Premier Billards & Design 1 1/7/05 Room Name Task/Activity Description Room Length (L) Room Width (W) Koom Cavity Height (H) Room Cay. Ratio 5xHx(L+W) /(LxW) . - a Room Name Task/Activity Description Room Area (A) Room Perimeter (P) Room Cavity Height (H) Room Cay. Ratio 2.5 x H x P /A LIGHTING MANDATORY MEASURES LTG -MM MINIM Premier Billards & Design 1/7/05 DESCRIPTION Designer Enforcement r § 131(d)l For every floor, all interior lighting systems shall be equipped with a separate automatic control to shut off the lighting. This automatic control shall meet the requirements of Section 119 and may be an occupancy sensor, automatic time switch, or other device capable of automatically shutting off the lighting. § 131(d)20verride for Building Lighting Shut-off: The automatic building shut-off system is provided with a manual, accessible override switch in sight of the lights. The area of override is not to exceed 5,000 square feet. u § 119(h) Automatic Control Devices Certified: All automatic control devices specified are certified, all alternate equipment shall be certified and installed as directed by the manufacturer. �J § 111 Fluorescent Ballast and Luminaires Certified: All fluorescent fixtures specified for the project are certified and listed in the Directory. All installed fixtures shall be certified. [XI § 132 Tandem Wiring for One and Three Lamp Fluorescent Fixtures: All one and three lamp s fluorescent fixtures are tandem wired with two lamp ballasts where required by Standards Section 132; or all one and three lamp fluorescent fixtures are specified with electronic high -frequency ballasts and are exempt from tandem wiring requirements. L-] § 131(a) Individual Room/Area Controls: Each room and area in this building is equipped with a separate switch or occupancy sensor device for each area with floor -to -ceiling walls. u § 131(b) Uniform Reduction for Individual Rooms: All rooms and areas greater than 100 square feet and more than 0.8 watts per square foot of lighting load shall be controlled with bi-level switching for uniform reduction of lighting within the room. U § 131(c) Daylight Area Control: All rooms with windows and skylights that are greater than !� 250 square feet and that allow for the effective use of daylight in the area shall have 50% of the lamps in each daylit area controlled by a separate switch; or the effective use of daylight cannot be accomplished because the windows are continuously shaded by a building on the adjacent lot. Diagram of shading during different times of the year is included on plans. § 131(f) Control of Exterior Lights: Exterior mounted fixtures served from the electrical panel inside the building are controlled with a directional photo cell control on the roof and a corresponding relay in the electrical panel, or uses an astronomical time clock. § 131(e) Display Lighting. Display lighting shall be separately switched on circuits that are - 20 amps or less. § 130(c) . Efficacy of Exterior Lights: Exterior mounted fixtures with lamps over 100 Watts served from the electrical panel inside the building have a source efficacy of at least 60 lumens per Watt, or are controlled by a motion sensor. EnergyPro 3.1 By EnergySoft User Number: 5533 Job Number: Page:10 of 11 MECHANICAL VENTILATION MECH-3 Premier Billards & Design 1/7/05 a © a o a F© o 0 o a ZONE/SYSTEM Premier Billards HVAC -5 I AREA BASIS AREA CFM CFM (SF) PER SF (B x C) OCCUPANCY BASIS REQ'D O.A. (MAX OF D OR G) DESIGN OUTDOOF AIR CFM VAV MIN. RATIO TRANS FER AIR NO OF PEOPLE CFM PER PERSON MIN. CFM (ExF) 741 537 204 Total 741 537 C Minimum Ventilation Rate per Section 121, Table 1-F. E Based on Expected Number of Occupants or at least 50% of Chapter 10 1997 UBC Occupant Density. I Must be greater than or equal to H, or use Transfer Air. Design Outdoor Air includes ventilation from Supply Air System & Room Exhaust Fans. K Must be greater than or equal to (H minus 1), and, for VAV, greater than or equal to (H -J). EnergyPro 3.1 By EnergySoft User Number: 5533 Job Number: Page: 11 of 15 Certificate of'Occupancy � - - _ WTaf 4 IM%�TM OF�w Building & Safety Department , This Certificate is issued pursuant to the requirements of Section 109 of the California Building Code, certifying that, at the time of issuance, this structure was in compliance with the provisions of the Building Code and the various ordinances of the City regulating building construction and/or use. BUILDING ADDRESS: 79-400 Highway 111 Suite 102 Use classification: Commercial "Premier Billiards" Tenant Improvement Building Permit No.: 05-0332 Occupancy Group: M Type of Construction: VN Land Use Zone: CR Owner of Building: Neil Kleine Address: 41910 Boardwalk A-10 City, ST, ZIP: Palm Desert, CA 92211 By: Daniel P. Crawford Jr. Date: 5/17/05 Building Official POST IN A CONSPICUOUS PLACE 7o