Loading...
05-4192 (CSCS)F y Certificate of Occupanc1782 1 F Building & Safety Department OF This Certificate is issued pursuant to the requirements of Section 109 of the California Building I Code, certifying that, at the time of issuance, this structure was in compliance with the provisions of the Building Code and the various ordinances of the City regulating building construction and/or use. BUILDING ADDRESS: 79-410 Highway 111 Suite 106 Use classification: Commercial "Budget Blinds" Retail Building Permit No.: 05-4192 Occupancy Group: M Type of Construction: VN Sprinkled Land Use Zone: CIR Improved Shell Building Tenant Change of Use, Special Inspection Owner of Building: Mr. Chang Kim Address: 2114 ARI Lane City, ST, ZIP: Los Angeles, CA 90049 By: Daniel P. Crawford Jr. Date: 9/27/05 Building Official POST IN A CONSPICUOUS PLACE TITLE 24 REPORT Title 24 Report for: Suite 106 T.I., La Quinta Valley Plaza 79-410 Highway 111 (Building 6) La Quinta, Ca 92253 CITY OF LA CSUINTA BUILDING & SAFETY DEFT. APPROVE[ FOR CONSTRUCTION DA � D5- BY. Project Designer: Robert Pitchford, Architect 74-835 Fox Hills Palm Desert, Ca 92260 (760) 346-8775 Report Prepared By: Tim Scott H & H Air Conditioning 74-991 Joni Drive #20 Palm Desert, CA 92260-2043 (760) 340-3088 Job Number: Date: 4/15/05 The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2001 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC (415) 883-5900. EnergyPro 3.1By EnergySoft Job Number: User Number: 5533 7 1 11 TABLE OF CONTENTS Cover Page Table of Contents Nonresidential Performance Title 24 Forms Form LTG -4 Tailored LPD Summary and Worksheet Form LTG -5 Room Cavity Ratio Worksheet Form LTG -MM Lighting Mandatory Measures MECH 3 Mechanical Ventilation 1 2 3 8 9 10 11 EnergyPro 3.1 By EnergySoft Job Number: User Number 5533 PERFORMANCE CERTIFICATE OF COMPLIANCE Part 1 of 3 PERF -1 'PROJECT NAME This Certificate of Compliance lists the building features and performa ce specifications needed to comply with Title 24, Parts 1 and DATE Suite 106 T.I., La Quinta Valley Plaza SIGNA-T 4/15/05 PROJECT ADDRESS 15 BUILDING TYPE NONRESIDENTIAL 79-410 Highway 111 (Building 6) La Quinta HIGH RISE RESIDENTIAL HOTEL/MOTEL GUEST ROOM Building Permit # PRINCIPAL DESIGNER - ENVELOPE TELEPHONE Robert Pitchford, Architect (760) 346-8775 mechanical engineer, electrical engineer or architect. /DOCUMENTATION AUTHOR TELEPHONE Checked by/Date L H & H Air Conditioning (760) 340-3088 Enforcement Agency Use ISTATEMENT OF COMPLIANCE This Certificate of Compliance lists the building features and performa ce specifications needed to comply with Title 24, Parts 1 and 6, of the State Building Code. This certificate applies only to a Buildin using tperformance compliance approach. rDOCUMENTATION AUTHOR SIGNA-T DATE 860 Sq.Ft. 15 BUILDING TYPE NONRESIDENTIAL IThe Principal Designers hereby certify that the proposed building design represented in the construction documents and nliodelled HIGH RISE RESIDENTIAL HOTEL/MOTEL GUEST ROOM PHASE OF CONSTRUCTION NEW CONSTRUCTION ❑ ADDITION ❑ ALTERATION EXISTING + ADDITION ISTATEMENT OF COMPLIANCE This Certificate of Compliance lists the building features and performa ce specifications needed to comply with Title 24, Parts 1 and 6, of the State Building Code. This certificate applies only to a Buildin using tperformance compliance approach. rDOCUMENTATION AUTHOR SIGNA-T DATE Tim Scott _ 44 / . 0 S IThe Principal Designers hereby certify that the proposed building design represented in the construction documents and nliodelled for this permit application are consistent with all other forms and worksheets, specifications, and other calculations submitted with this permit application. The proposed building as designed meets the energy efficiency requirements of the State Building Code, Title 24, Part 6. ENV. LTG. MECH. ❑ F-] 1. 1 hereby affirm that I am eligible under the provisions of Division 3 of the Business and Professions Code to sign this document as the person responsible for its preparation; and that I am licensed as a civil engineer, mechanical engineer, electrical engineer or architect. r-1 r— I r�l 2. 1 affirm that I am eligible under the provisions of Division 3 of the Business and Professions Code Section l �1 I_J —1 5537.2 or 6737.3 to sign this document as the person responsible for its preparation; and that I am a licensed contractor preparing documents for work that I have contracted to perform. u 3. 1 affirm that I am eligible under Division 3 of the Business and Professions Code to sign this document because it pertains to a structure or type of work described as exempt pusuant to Business and Professions Code Sections 5537, 5538, and 6737.1. (These sections of the Business and Professions Code ae printed in full in the Nonresidential Manual.) Indicate location on plans of Note Block for Mandatory Measures Envelope Compliance Not In The Scope Of Required Forms Ti1fS Submittal CPRINCIPAL ENVELOPE -DESIGNER -NAME SIGNATURE-IC-NO�jDATE ILIGHTING COMPLIANCE Indicate location on plans of Note Block for Mandatory Measures R I d F LT -1 P NCIPAL LI TING D IGNER - N �1 LIC. NO. DggTE ,' T 1 .�7C W).— G1231�j b-1 1'065 Indicate location on plans of Note Block for Mandatory Measures Mechanical Compliance Not In the Scope 101 Required Forms This Submittal PRINCIPAL MECHANICAL DESIGNER - NAME I SIGNATURE ILIC. NO. I DATE j Run Initiation Time: 04/15/05 08:13:27 Run Code: 1113578007 lEnergyPro 3.1 By EnergySoft _ User Number: 5533 Job Number: Page:3 of 11 PERFORMANCE CERTIFICATE OF COMPLIANCE Part 2 of 3 PERF -1 DATE Suite 106 T.I., La Quinta Valley Plaza 4/15/05 ANNUAL SOURCE ENER6Y USE SUMMARY u sq -yr ENERGY COMPONENT Standard Design Proposed Design Compliance Margin( 5tandaid_ 'Proposed Space Heating Space Cooling Indoor Fans Heat Rejection Pumps & Misc. Domestic Hot Water Lighting Receptacle Process TOTALS: 0.35 0.70 -0.35 48.84 38.37 10.47 15.70 12.56 3.14 1nO-F-" ONE 0.00 0.00 0.00 0.00 0.00 0.00 r °" 0.00 0.00 0.00 50.23 23.37 26.8 16.05 16.05 0.00 ReeeF Klu'` 0.00 0.00 131.16 91.05 40.12 :.0 - 10. ., 20,. - 30 .40 S0. ketwsgh-yr GENERAL INFORMATION Building Orientation Number of Stories Number of Systems Number of Zones (East) 90 deg Conditioned Floor Area 860 sgft. 1 Unconditioned Floor Area 0 sgft. 1 Conditioned Footprint Area 0 sgft. 1 Orientation Front Elevation (East) Left Elevation (South) Rear Elevation (west) Right Elevation (North) Total Roof Gross Area sgft. sgft. sgft. sgft. sgft. sgft. Glazing Area Glazing sgft. sgft. sgft. sgft. sgft. sgft. Ratio 0 0 0.0% 0 0 0.0% 0 0 0.0% 0I 0 0.0% 0 0 0.0% 01 E::� o.o°i° Standard Proposed Lighting Power Density 1.700 wisgft. 0.793 wisgft. Prescriptive Env. Heat Loss o 0 Prescriptive Env. Heat Gain 0 0 emar s: Run InitiationTime: un Code: 1113578001 EnergyPro 3.1 By EnergySoft User Number: 5533 Job Number: Page:4 of 11 PERFORMANCE CERTIFICATE OF COMPLIANCE Part 3 of 3 PERF -1 (PROJECT NAME Suite 106 T.I., La Quinta Valley Plaza DATE 4/15/05 System Name Zone Name Occupancy Type Floor Area (sqft.) Inst. LPD (W/sf)1 Port.Ctrl. lailorea LPD Credits (W/sf)1 (W/sf)2 (W/sf)3 Proc. Loads (W/sf) HVAC 1 Suite 106 Comp Bldg Retail/Wholesa a 860 0.072 0.72 Notes: 1. See LTG -1 (items marked with asterisk, see LTG -2 by others) 2. See LTG -3 3. See LTG -4 Items above require special documentation I ne local enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The local enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted. I Plan I Field The exceptional features listed in this performance approach application have specifically been reviewed. Adequate written justification and documentation for their use have been provided by the applicant. Authorized Signature or Stamp 1 Kun Initiation I Ime: U4/1b/Ub Ut3:13:Z/ Kun Code: 1113578007 1 EnergyPro 3.1 By EnergySoft User Number: 5533 Job Number: Page:5 of 11 LIGHTING COMPLIANCE SUMMARY Part 1 of LTG -1 I Suite 106 T.I., La Quinta Valley Plaza 4/15/05 1 LAMPS RAI I ARTc Lu�inaire---1 Code LUMINAIRE DESCRIPTION TYPE DESCRIPTION # Watts Per Lamp DESCRIPTION # (Lamp + Ballas rTotal Watts # Watts (2) 4 ft Fluorescent T8 Elec F32T8 2 32 Electronic 1.0 1 62.0 62 Lighting Schedule on Plans Shows Exterior Lighting Subtotal from this Page 62 Meets Total 62 620 Efficacy and Control Requirement ofg130(c) Portable Lighting (From LTG -1) Control Requirements of §131(f) Less Control Credit Watts (From LTG -3) Adjusted Actual Watts 682 NOTE TO FIELD _IGHTING COMPLIANCE SUMMARY Part 2 of 2 LTG -1 Suite 106 T.I., La Quinta Valley Plaza 1 4/15/05 1 o a a o o a a LUMIN. TASK # OF TOTAL TOTAL ROOM # PORTABLE LIGHTING # OF WATTS PER AREA TASK AREA (SF) WATTS OR ZONE ID np—rinfinn FIXT FIXTI IRF ISP% eocec In _ n 1r - — Suite 106 (4) 4 ft Fluorescent T8 Elec 5 124.0 860 1 860 620 TOTAL 860 620 ROOM # OR ZONE ID TOTAL AREA (SF) Designer needs to provide detailed documentation that the lightin level provided by the overhead lighting meets the needs of the space. The details include luminaire types, CU, and mounting locations relative to work areas. TOTAL 0 BUILDING SUMMARY (FROM TABLES 1A+16+1 C) (FROM TABLES 1A+1B) BUILDING TOTAL 860 620 Run Initiation—Time: 04/15/05-797 un Code: 1113378007 EnergyPro 3.1 By EnergySoft User Number. 5533 Job Number: Page:7 of 11 �AILORED LPD SUMMARY and WORKSHEET Part 1 of 3 LTG -4 Suite 106 T.I., La Quinta Valley Plaza 4/15/05 uminance CategoneS , and U and Gross baleS Area a a a 1. Watts for Illuminance Categories A -D (from column G) 0 watts 2. Watts for Illuminance Categories E-1 (from LTG -4 Part 2) 0 watts 3. Watts for Display Lighting (from LTG -4 Parts 2 & 3) ROOM NAME 0 + + 0 = 0 watts Public Area Display Sales Feature Floor Display Sales Feature Wall Display FLOOR AREA 4. Total Allowed Watts (lines 1+2+3) > 0 watts uminance CategoneS , and U and Gross baleS Area a a a o 0 0 19 ROOM NAME TASK/ACTIVITY ILLUMINANCE CATEGORY ROOM CAVITY RATIO FLOOR AREA ALLOWED LPD ALLOWED WATTS (E x F) Sino A 2.01 0 0.20 0 PAGE TOTAL 0 01 BUILDING TOTAL > 860 SF WATTS J EnergyPro 3.1 By EnergySoft User Number: 5533 Job Number: Page:8 of 11 ROOM CAVITY RATIO WORKSHEET (RCR>=3.5) LTG -5 Suite 106 T.I., La Quinta Valley Plaza 1 4/15/05 1 Room Name Task/Activity Description Room Length (L) Room Width (W) Room Cavity Height (H) Room Gay. Ratio 5xHx(L+W) /(LxW) Room Name Task/Activity Description Room Area (A) Room Perimeter (P) Room Cavity Height (H) Room Cay. Ratio 2.5 x H x P /A LIGHTING MANDATORY MEASURES LTG -MM Suite 106 T.I., La Quinta Valley Plaza 4/15/05 DESCRIPTION Designer Enforcement [XI § 131(d)1 For every floor, all interior lighting systems shall be equipped with a separate automatic control to shut off the lighting. This automatic control shall meet the requirements of Section 119 and may be an occupancy sensor, automatic time switch, or other device capable of automatically shutting off the lighting. u § 131 (d)2 Override for Building Lighting Shut-off: The automatic building shut-off system is provided with a manual, accessible override switch in sight of the lights. The area of override is not to exceed 5,000 square feet. § 119(h) Automatic Control Devices Certified: All automatic control devices specified are certified, all alternate equipment shall be certified and installed as directed by the manufacturer. (� § 111 Fluorescent Ballast and Luminaires Certified: All fluorescent fixtures specified for the project are certified and listed in the Directory. All installed fixtures shall be certified. [XI X § 132 Tandem Wiring for One and Three Lamp Fluorescent Fixtures: All one and three lamp fluorescent fixtures are tandem wired with two lamp ballasts where required by Standards Section 132; or all one and three lamp fluorescent fixtures are specified with electronic high -frequency ballasts and are exempt from tandem wiring requirements. u § 131(a) Individual Room/Area Controls: Each room and area in this building is equipped with a separate switch or occupancy sensor device for each area with floor -to -ceiling walls. CXJ § 131(b) Uniform Reduction for Individual Rooms: All rooms and areas greater than 100 square feet and more than 0.8 watts per square foot of lighting load shall be controlled with bi-level switching for uniform reduction of lighting within the room. LX� § 131(c) Daylight Area Control: All rooms with windows and skylights that are greater than f, 250 square feet and that allow for the effective use of daylight in the area shall have 50% of the lamps in each daylit area controlled by a separate switch; or the effective use of daylight cannot be accomplished because the windows are continuously shaded by a building on the adjacent lot. Diagram of shading during different times of the year is included on plans. § 131(f) Control of Exterior Lights: Exterior mounted fixtures served from the electrical panel inside the building are controlled with a directional photo cell control on the roof and a corresponding relay in the electrical panel, or uses an astronomical time clock. l_.J § 131(e) Display Lighting. Display lighting shall be separately switched on circuits that are 20 amps or less. § 130(c) Efficacy of Exterior Lights: Exterior mounted fixtures with lamps over 100 Watts served from the electrical panel inside the building have a source efficacy of at least 60 lumens per Watt, or are controlled by a motion sensor. EnergyPro 3.1 By EnergySoft User Number: 5533 Job Number: Page: 10 of 11 MECHANICAL VENTILATION MECH-3 Suite 106 T.I., La Quinta Valley Plaza 4/15/05 FA © a a a o© a a o 0 EnergyPro 3.1 By EnergySoft User Number: 5533 Job Number: Page: 11 of 15 AREA BASIS OCCUPANCY BASIS REQ'D O.A. (MAX OF D OR G) DESIGN OUTDOOF AIR CFM VAV MIN. RATIO TRANS FER AIR ZONE/SYSTEM CND. AREA (SF) CFM PER SF CFM (B x C) OF PEOPLE PER PERSON CFM (ExF) Suite 106 860 0.23 198 198 86 112 HVAC 1 Total 198 86 C E I K Minimum Ventilation Rate per Section 121, Table 1-F. Based on Expected Number of Occupants or at least 50% of Chapter 10 1997 UBC Occupant Density. Must be greater than or equal to H, or use Transfer Air. Design Outdoor Air includes ventilation from Supply Air System & Room Exhaust Fans. Must be greater than or equal to (H minus 1), and, for VAV, greater than or equal to (H -J). EnergyPro 3.1 By EnergySoft User Number: 5533 Job Number: Page: 11 of 15