Loading...
07-2713 (RC)P.O. BOX 1504 78-495 CALLE TAMPICO f LA QUINTA, CALIFORNIA 92253 Application Number: =07-00002713_ - Property Address: 79485 HIGHWAY 111 STE APN: 600-020-027- - Application description: REMODEL - COMMERCIAL Property Zoning: REGIONAL COMMERCIAL Application valuation: 15000 Applicant: Architect or Engineer: BUILDING & SAFETY DEPARTMENT BUILDING PERMIT ----------=--------------------------------------- LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professionals Code, and my License is in full force and effect. Licen ass: B LicenseNo.: 874137 ate: "L ontractor. " OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the following reason (Sec. 7031 .5, Business and Professions Code: Any city or county that -requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file'a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than'five hundred dollars ($500).: (_ 1 I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractor's' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herselfthroughhis or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have .the burden of proving that he or she did not build or improve for the purpose of sale.). (_ 1 I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). (_ 1 I am exempt under Sec. , B.&P.C. for this reason Date: Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Name: , Lender's Address: JJ tr. LQPERMIT Owner: STAMKO DEV CO 10345 W OLYMPIC BLV 2 LOS ANGELES, CA 90064 Contractor: REYES,'JOEL DAVID . 46150 RUBIDOUX STREET INDIO, CA 92201 (760)844-6224 Lic. No.: 874137 VOICE (760) 777-7012 FAX (760) 777-7011 INSPECTIONS (760) 777-7153 Date: 1/04/08 ------------------------------------------------ WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: _ I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided .- for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier EXEMPT Policy Number EXEMPT I certify that, in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, if I should become subject to the workers' compensation provisions of Section 3700 of the La Code, I shall forthwith comply with those provisions. te: G` plicant: 1:R0,_Obb WARNING: FAILURE TO SECURE WORK S' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL ' SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST.OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. ' APPLICANT ACKNOWLEDGEMENT IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the conditions and restrictions set forth on this application. 1 . Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application, the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of %th's county to enter u the above-mentioned property for iinspection purposes``(^/ Date: y G Signature (Applicant or Agent): a Application Number . . . 07-00002713 ------ Structure Information 1,300SF TI/V-NR/B-OCC/31-OL ----- Other struct info CODE EDITION 2001/2004'/2005 _ FIRE SPRINKLERS FULLY Y, MIXED-USE OCCUPANCY B OCCUPANT LOAD 31.0.0 -------------------7-------------------------------------------------------- 1ST FLOOR SQUARE FOOTAGE 1300.00 Permit . . . BUILDING PERMIT Additional desc . Permit Fee . . . . 162'.00 Plan Check Fee 105.30 Issue Date . . . . Valuation . . . . 15000 Expiration Date 7/02/08 Qty Unit Charge Per Extension BASE FEE 45.00 13.00 9.0000 -------------------------- THOU BLDG 2,001-25,000 ---------------------------------- 117.00 ---------------- Permit . . . ELECT - ADD/ALT/REM Additional desc . Permit Fee . . . . 42.60 Plan Check Fee 10.65 Issue Date . . . . Valuation . . . . 0 Expiration Date 7/02/08 Qty Unit Charge Per Extension BASE FEE 15.00 • 20.00 .7500 PER ELEC DEVICE/FIXTURE 1ST 20 15.00 28.00 .4500 ---------------------------------------------------------------------------- EA ELEC DEVICE/FIXTURE >20 12.60 Permit . . . MECHANICAL Additional desc . Permit Fee . . . . 19.50 Plan Check Fee 4.88 Issue Date Valuation . . 0 Expiration Date 7/02/08 Qty Unit Charge Per Extension BASE FEE 15.00 ' 1.00 4.5000.EA ---------------------------------------------------------------------------- MECH VENT INST/ DUCT ALT 4.50 Permit . . . PLUMBING Additional desc . . Permit Fee 100.50 Plan Check Fee 25.13 Issue Date Valuation 0 Expiration Date 7/02/08 • LQPERMIT , - Application Number . . . . 07-00002713,, Permit . . . . . . PLUMBING c Qty Unit Charge Per Extension BASE FEE 15.00 �. 10.00 6.0000 EA PLB FIXTURE 60.00 1.00 15.0000 EA PLB BUILDING SEWER 15.00 1..00 7.5000 EA PLB WATER HEATER/VENT 7.50 1.00 3.0000 EA PLB WATER INST/ALT/REP 3.00 ---------------------------------------------------------------------------- Special Notes and Comments 1,300SF TI/V-NR/B-OCC/31-OL/SPRINKLED [JUMPIN JUICE AND JAVA] THIS PERMIT DOES NOT INCLUDE BUILING SIGNAGE OR GREASE INTERCEPTOR. 2001 CBC, CMC, CPC, 2004 CEC, 2005 ENERGY.- THE APPROVAL OF PLANS AND SPECIFICATIONS DO NOT PERMIT THE VIOLATION OF ANY BUILDING, MECHANICAL, ELECTRICAL, PLUMBING, OR ENERGY CODE OR OTHER CITY ORDINANCE, STATE OR FEDERAL LAW. I January 4, 2008 9:43:47 AM AORTEGA ------------------------------------------1=--=---------------------------- -------------------------------------------- ---------------------------------- Other Fees . . . . . . . . . ACCESSIBILITY PLAN REVIEW Other 10.53 ENERGY REVIEW FEE 10.53 Fee summary Charged Paid Credited Due Permit Fee Total 324.60 .00 .00 324.60 " Plan Check Total 145.96 .00 .00 145.96 Other Fee Total 21.06 .00 .00 - 21.06 Grand Total 491.62 .00 .00 491.62 LQPERMIT ` CITY F LA JOB ADDRESS -4195- � �^�" t •'v� PERMIT NO MBER�UINTA SUB -CONTRACT FACTO .LIST t� _BUILDER �:x-��v 1 �o ctz. f.-� � • This fo�m's?�all be posted on the iob with the Building Inspection Card at all times in a conspicuous glace. Only per ons appearing on this list or their employees are authorized to work on this idb. Any changes .to this list must be approved by the Building Division prior to commencement of work. Failure to comply will result in a stoppage of work and/or the voidance. IN tam �•� - fCertiicat_e of Occupancy o o V OF uilding & Safety Department This Certificate is issued pursuant to the requirements of Section 109 of the California Building Code, certifying that, at the time of issuance, this structure was in compliance with the k provisions of the Building Code and the various ordinances of the City regulating building construction and/or use. y z BUILDING ADDRESS: 79-485 HIGHWAY 111. SUITE #8 Use classification: JUMPIN JUICE AND JAVA Building Permit No.: 07-2713 7 X Occupancy Group: B Type of Construction: V -NR (SPRINKLED) Land Use Zone: CR x 4 2 r Owner of Building: STAMKO DEVELOPMENT, CO. Address: 6080 CENTER DRIVE. #668 City, ST, ZIP: LOS ANGELES, CA 90045 By: AJ ORTEGA Date:_ MAY 5. 2008 Building Official POST IN A CONSPICUOUS PLACE Bin # , - . City of La Quinta Building �1 Safety Division P.O. Box -1504, 78-495 Calle Tampico La Quinta, CA 92253 - (760) 777-7012 Building Permit Application and Tracking. Sheet Permit # 1� Project Address: —)01 14 48,5 WII( so-ME . Owner's Name:e ' A. P. Number: Address: Legal Description: 7 Contractor: E �N C , City, ST, Zip: I t) Telephone: Address: Lf(� r) O o ` D ( A-A OD I"b Project Description: City, ST, Zip: �� S�KT CA'22- G O Telephone: -7 6 0$ 4 2 Z State Lic. # : City Lic. #: Arch., Engr., Designer: D Com, Address: —,26183 0 <-::.0 City, ST, Zip: P>(, AN Telephone- '74, c3 1q90 301 Construction Type: Occupancy: . Project type (circle one). Nei Add'n Alter Repair Demo State Lic. #: g 3'� Name of Contact Person:C IG Sq. Ft.: pp # Stories: # Units: Telephone # of Contact Person: %h6 ASO ? b I io Estimated Value of Projec APPLICANT: DO NOT WRITE BELOW THIS LINE # Submittal Req'd Recd TRACKING. PERMIT FEES' Plan Sets Plan Check submitted I Item Amount Structural Cates. Reviewed, ready for corrections Plan Check Deposit Truss Cates. Called Contact Person 11114plan, Check Balance Energy Cates.Plans picked up fJ 7 Construction Flood plain plan Plans resubmitted 1I Mechanical Grading plan f 2"" Review, ready for correctionshssue II Z Electrical Subcontactor List Called Contact Person It zq I07 Plumbing Grant Deed Plans picked up Cp�� L. 2 S.M.I. H.O.A. Approval Plans resubmitted ' ¢j Grading IN HOUSE:- ''" Review, ready for correctionslissue '� Developer Impact Fee Planning Approval Called Contact Person A.I.P.P. Pub. Wks. Appr Date of permit issue School FeesV\ nlo Total Permit Fees i6Jn �g - c..u�J�, ��wlo�e-ML 6xce-a xsaeo-o ot P.O. BOX 1504 BUILDING & SAFETY DEPARTMENT 78-495 CALLE TAMPICO (760) 777-71012 LA QUINTA, CALIFORNIA 92253 FAX (760) 777-7011 To: Greg Butler, Building & Safety Manager To PD: 10-05-07 From: Les Johnson, Director -PDD Due Date: 10-11-07 Permit #: 07-2713Status: 1ST REVIEW �h Building Plans Approval (This approval to issue a Building Permit) The Planning Department has reviewed the Building Plans for the following project: Description: TENANT IMPROVEMENT / COFFEE SHOP Address or General Location: 79485 HWY 111 STE. 8 Applicant Contact:CANDICE HOT 760-880-3016 i The Planning Development Department -finds that: ❑ ...these Building Plans do not require Community Development Department approval. ' rr ..these Building Plans are approved by the Community Development Department. Plc.c c« aKd M��v. ❑ ...these Building Plans require corrections. Please forward a copy of the attached corrections to the applicant. When the corrections are made please return them to the Community Development Department for review. Les Johnson Director -PD Date I RIVERSIDE 'COUNTY COMMUNITY HEALTH AGENCY DEPARTMENT OF ENVIRONMENTAL HEALTH FOOD ESTABLISHMENT PLAN APPROVAL NOTICE Plan Check # 9596 Date 12/20/07 Project Name JUMP/N JUICE & JAVA Address 79-485 Hwy 111 "08", La Quinta Plans Submitted by Candice Noto Phone (760)8803016 Owner Carl McPeters Address Phone The plans are now approved subject to the conditions listed below and the attached compliance sheet. 1) An approved 5' high sneeze guard is required around -front service counter. 2) "Glass" pendent lights are not permitted above front service counter or any other employee area. Remove/ relocate to customer area. 3) Provide an approved 50 gallon water heater capable of producing a minimum 49,000 btu's or 11 kw's. 4) All painted walls in employee areas must be a light colored, gloss or semi -gloss. 5) Concrete floor must be sealed with an approved sealer from the County of Riverside list. 6) Sanitary ceramic tile base cove is the only acceptable base cove with a concrete floor. 7) Provide grease interceptorsizing letter from the local sewer agency or Riverside County Land Use at (760) 393-3390. CONSTRUr., ,ON INSPFr" intact the Plan Checker for a Preliminary Inspection when construction is approxirr dui ,umbing, rough ventilation, and rough equipment installed. Request for ins five (5) working days.in advance. A )e made upon completion of ALL work including finished details. APPROVAL to of a remodeled areas approved to operate, until the facility has passed the FINAL IP:. ,ATION TO OPERATE" has been completed and PERMIT FEES have been paid. ar inspection should be made at least five (5) working days in advance. Dan Blum Phone (760) 320-1048 corrections noted herein and as indicated on the plans and agree to incorporate them during Signature Date /Z/72/A7 Company Name2�e ��cS-� , o .N-178 (Rev 2/06) Corona Hemet Indio. Murrieta Palm Springs Riverside 2275 S. Main St Suite 800 S. Sanderson 47-950 Arabia St 38740 Sky Canyon Dr 2500 N. Palm Canyon 4065 County Cir 204 (951) 766-2824 "A" (951) 461-0284 Dr (951) 358-5172 10C1N 1n9 01 nn C.... /0=1 N'7cc "O"A f7cn10413 01107 n...,,hcl\ n41 mnc ,"cm inn 1rmo U..., mcl� ago COUNTY OF RIVERSIDE COMMUNITY HEALTH AGENCY . DEPARTMENT OF ENVIRONMENTAL HEALTH ENVIRONMENTAL HEALTH SERVICES SUPPLEMENTAL REPORT TO SAN. FORM # DATE SUBJECT PERMIT NO. ADDRESS INSPECTOR REMARKS: � �' n S ; 0^ (" 1 , t a L– N�1 t" C rl o .. n i A a o 1 0A. -i '- I— I kc .J ! � t t /\ C 0 1 1 C 4 k c ra a\\ 0�\,J J `l�� " /14, -7y r• 9EWSAN-118 (Rev eroz) Distribution: WHITE—Office; CANARY—Owner; PINK—Office John R. Hawkins Fire Chief Proudly serving the unincorporated areas of Riverside County and the Cities of - Banning .; Beaumont .; Calimesa ❖. Canyon Lake Coachella 4. - Desert Hot Springs Indian Wells Indio Lake Elsinore 4. La Quinta 4. Moreno Valley 44- Palm ;Palm Desert 4. Penis Rancho Mirage .; Rubidoux CSD San Jacinto 4 Temecula Board of Supervisors Bob Buster, District I John Tavaglione, District 2 Jeff Stone, District 3 Roy Wilson, District 4 Marion Ashley, District 5 RIVERSIDE COUNTY FIRE DEPARTMENT In cooperation with the `California Department of Forestry and Fire Protection i 77-933 Las Montanas Rd. STE 201 Palm Desert, CA 92211-4131 (760) 863-8886 Fax (760) 863-7072 I: i I Dater 5 l J La Quinta 'Building Department i RE, Juw► iN 141f� r a Joy The Riverside County Fire Department is granting the fire clearance for the following location -% 9—'� $5 W w Please call if you should have questions. 760-863-8886. Thank You t t t t i RRespectfully, 5 JasN Stubble Fire Safety Specialist e t , 5 JasN Stubble Fire Safety Specialist John R. Hawkins Fire Chief Proudly serving the unincorporated areas of Riverside County and the . Cities of. Banning Beaumont Calimesa Canyon Lake Coachella Desert Hot Springs Indian Wells Indio ❖ . Lake Elsinore La Quinta Moreno Valley ev Palm Desert S 4. Perris Rancho Mirage San Jacinto Temecula Board of Supervisors Bob Buster, District I John Tavaglione, District 2 Jeff Stone, District 3 Roy Wilson, District 4 Marion Ashley, District 5. . I RIVERSIDE JNTY FIRE DEPA _ MENT In cooper .ttion with the California Department -of Forestry and Fire Protection 77-933 Las Montanas Rd., Suite 201 • Palm Desert, California 92211 • (760)' 863-8886 • Fax (760) 863-7072 October 24, 2007 Applicant: Candice C. Notto 74-830 Velie Way Suite A 760-880-3016 RE: TENANT IMPROVEMENT PLAN CHECK LAQ-07-TI-124 / J.UMPIN JUICE AND JAVA 79-485 HWY 111 SUITE 08 LA QUINTA, CA You have been issued a release for a tenant improvement on an existing building. THIS IS NOT AN OCCUPANCY PERMIT. It is prohibited to use/process or store any materials in this occupancy that would classify occupancy per Sec. 307 of the 2000 UBC. fy It as an "H" THE FOLLOWING CONDITIONS MUST BE MET PRIOR TO INSPECTION: Install door hardware and exit signs as per Chapter 10 of the 2001 CBC. Fire sprinkler system plans for the tenant improvement area must be submitted to the Fire Department for review, along with a plan/inspection fee. A licensed C-16 contractor will have to submit plans for review and approval and modify the fire sprinkler system in accordance with NFPA 13, 1999 Edition: A licensed C-16 contractor, shall do all sprinkler work and certification. The approved plans, with Fire Department Job card must be at the job site for all inspections. Provide keys ,to the tenant space for inclusion in the main building Knox Box. Key(s) shall have durable and legible tags affixed for identification of the correlating tenant space. Install Knox Lock Boxes, Models 4400, 3200 or 1300, mounted per recommended standard of the Knox Company. Plans. -must be submitted to the Fire Department for approval of mounting location/positio of the Key Lock Boxes. This form must be authorized and signed by this on and operating standards. Special forms are available from this office for the ordering office for the correctly coded system to be purchased. If the building/facility is protected with a fire alarm system or burglar alarm system, the lock boxes will require "tamper' monitoring. Shelving, counters, etc., must be in place, however, no merchandise may be placed in the building prior to inspection A minimum 2A10BC Fire Extinguisher, (State Fire Marshal Approved) must be mounted in a visible location within 75' walking distance from any point in your building or suite. Fire extinguishers can be installed by a licensed extinguisher company with a State Fire Marshal service tag attached to the extinguisher, or purchased from a retail store with a sales receipt attached. A licensed fire extinguisher company must service extinguisher yearly. 2300 Market Street, Suite 150. Riverside, California 9 (951) 955-4777 • Fax (951) 955-4886 39493 Los Alamos Road, Suite A. Murrieta, California.92563 . (951) 600-6160. Fax (951) 600-6164 V ' ELECTRICAL PANEL BOX: i All breakers must be labeled and a clearance of 36 inches must be maintained around the panel at all times. OTHER REQUIREMENTS: ,Approved building address- shall be placed in such a position as to be plainly visible and legible from the street and rear access if applicable. Building address numbers shall be a minimum of 12" for building(s) up to 25' in height, and 24" in height for building(s) exceeding 25' in height. In multi -tenant buildings, businesses shall post the business name and suite number on back doors as well as the front. Suite numbers or letters must be a minimum of 6" in height. All addressing must be legible and of a contrasting color with the background and adequately illuminated to be visible from the street at all hours. A durable sign stating "This door to remain unlocked during business hours" shall be placed on or adjacent to the front exit door. The sign shall be in letters not less than one inch high on a contrasting background.. Applicantlinstaller shall be responsible to contact the Fire Department to schedule inspections. A re -inspection fee will be required if more than one (1) inspection is necessary. Requests for inspections are.to be made at least 72 hours in advance and maybe arranged by calling (760) 863-8886. All questions regarding the meaning of these conditions should be referred to the Fire Department Planning & Engineering Staff at (760) 863-8886. 2300 Market Street, Suite 150 • Riverside, Califomia • (951) 955-4777 • Fax (951) 9554886 39493 Los Alamos Road, Suite A • Murrieta, California 92563 • (951) 600-6160 • Fax (951) 600-6164 COACHELLA VALLEY WATER DISTRICT ASSESSOR'S PARCEL: NUMBER 85-M MOO SZ, CoacheIIa,:CaWorn*01236.. . APPLICATION FOR.WASTEWATER.INTERCEPTORISEPAKATOR APPROVAL; APPLiCd1NT •,SabRdt tbie form wiWsi.copy ofaSCALED.ptot oah (' - W. to 1"r.44' SCALE) diaaato DistrictspeciHestiotn A aonrefimdabk 6lirig fee is rerrnired whet► the applicatiaa ii submito &Chock must be made payable to.the Ceacladh. Valley Wats District. Approval of this application shall.remain valid for a period . not b exceed ane (I) year fromdate of ..... .•PbmC6eck•Na • Agan, Coattaetor, Contact Pwn Adm ((may. state zip Tdephaae cam-= 7.�183o V �a Sal q 226 City Stater ZiP Tde*w Cdcz t_ c P rZS ci 65 -Lw"l I 11 08 Q V CA q Z h6 Pmp" Addmaa City `T. ,q$S:�wv tLegal DescrWon1\. . DBA . . MPitN V .cam J1�V� PLEASE. CONYi!tiETL THiS 3EC'YON: FSR`. REVYEW OF: FOOn:'ES'>GABSHMEr1'rS NOTI?a PI:AlYB WILL NM' BL At CEFTED UNLFSs'.TI4S i1Pi'LICAT70N n COMTL$18'AND THb`PLW CMEE7C FEE 15:PAi(D. GENEI4GL`C0N$TRU6TION ' Type of Coasts cdc' = New wod Pidli\y Ramadd of Haim ibod Et ort! . fiama of Opaatioa . I ,- gem h'. www i 0 External fiterm[SeatbogwithMistea.or[ireWa. Bai.whhFw&Serviae Bar:NoohWSa'wawsoReaer- rr.,'x:v.i•.,}�.rafVl�(1a�ahlC):4 .4'_V: _()�r_ - +-.��.o.,y..y.... .. OWNEIVMRESEKIATIVB DEC ARAnM l certify tbwfl tin a head tl►e e> a ap{►Heafioo emd•spde.tlid.atl irtfoaniat is ooeoct Ltrodasmnd t6atthe amamt of fa paid is banal an my deebratim..of irjtarmad on tau fwm and that tacorrect iuibtnsation �' grotmde. fa da W.of the 3bmitted p1m I also dW4pUnd that platin win,be dlacatded if not P aO Y i�): of q�psovd o; Q l a>sd'1Mt to iospe ua. .ary. ambt mmt Mill do ex ncoed; or gpmvd va—. d•tn opesabe, u*10, pnopa id las hero received i ad planabs" beau approved am�rmumd -7. a7 Na.'ofSyaoema cdsygn(d): No D+iiaog;thiita. Q saodlKiD :(irmclatacepmtwaivad; Fytt►ud:llai s 13 G oese:Iatereeptor E Nap` p F os Q Ifat hap:. QQ�Addidoo ClcbriHa. r I . TITLE 24 REPORT ' I Title 24 Report for: Jumpin' Juice & Java Tenant Improvement 79-485 Highway 111, Suite 8 La Quinta, Ca 92253 Project Designer: _ Candice Noto Designs 74-830 Velie Way, Suite E Palm Desert, Ca 92260 (760) 880-3016 Report Prepared By: Tim Scott Scott Design & Title 24 77085 Michigan Dr. Palm Desert, CA 92211 (760) 200-4780 Job Number: RM CITY OF LA QUINTA BUILDING & SAFETY DEPT. APPROVED FOR CONSTRUCTION Date: DA $ 4,oB 8Y 1/3/2008 he EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is uthorized by the California Energy Commission for use with both the Residential and Nonresidential 2005 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC - www.energysoft.com. EnergyPro 4.3 by EnergySoft Job Number: User Number: 6712 TABLE OF CONTENTS Cover Page Table of Contents Form LTG -1, C Certificate of Compliance Form LTG -2-C Indoor Lighting Schedule Form LTG -4-C Lighting Controls Credit Worksheet Form LTG -5-C Indoor Lighting Power Allowance Form LTG -7-C Room Cavity Ratio Worksheet Form LTG -MM Lighting Mandatory Measures Form MECH-1-C Certificate of Compliance Form MECH.-MM Mechanical Mandatory Measures 1 2 3 7 8 9 10 11 12 14 EnergyPro 4.3 by Energysoft Job Number: User Number: 6712 CERTIFICATE OF COMPLIANCE (Part 1 of 4) LTG -1-C ROJECT NAME DATE Jum in' Juice & Java Tenant Improvement 1/3/2008 ROJECT ADDRESS 79-485 Highway 111, Suite 8 La Quinta PRINCIPAL DESIGNER - LIGHTING TELEPHONE Building Permit # Candice Noto Designs (760) 880-3016 DOCUMENTATION AUTHOR TELEPHONE Checked by/Date Scott Design & Title 24 (760) 200-4780 1 Enforcement Agency Use GENERAL INFORMATION DATE OF PLANS BUILDING CONDITIONED FLOOR AREA CLIMATE ZONE 1,300 Sq.Ft. 15 BUILDING TYPE ❑X NONRESIDENTIAL ❑ HIGH RISE RESIDENTIAL ❑ HOTEUMOTEL GUEST ROOM ❑X CONDITIONED SPACES ❑ UNCONDITIONED SPACES ❑ INDOOR & OUTDOOR SIGNS PHASE OF CONSTRUCTION ❑X NEW CONSTRUCTION ❑ ADDITION ❑ ALTERATION METHOD OF LIGHTING ❑ COMPLETE BUILDING FX AREA CATEGORY ❑ TAILORED ❑ PERFORMANCE COMPLIANCE ❑ COMMON LIGHTING STATEMENT OF COMPLIANCE This Certificate of Compliance lists the building features and performance specifications needed to comply with Title 24, Parts 1 and 6 of the California Code of Regulations. This certificate applies only to building lighting requirements. The documentation preparer hereby certifies that the documentation is ccur a and complete. DOCUMENTATION AUTHOR SIGNAT DATE Tim Scott 3 0s The Principal Lighting Designer hereby certifies that the proposed building design represented in this set of construction documents is consistent with the other compliance forms and worksheets, with the specifications, and with any other calculations submitted with this permit application. The proposed building has been designed to meet the lighting requirements contained in Sections 110, 119, 30 - 132, 146, 148 & 149 of Title 24, Part 6. The plans & specifications meet the requirements of Part 6 (Sections 10-103a). ❑ The installation certificates meet the requirements of Part 6 (10-103a 3). E] The operation & maintenance information meet the requirements of Part 6 (10-103c). Please Check One: (These sections of the Business and Professions Code are printed in full in the Nonresidential Manual.) ❑ I hereby affirm that I am eligible under the provisions of Division 3 of the Business and Professions Code to sign this document as the person responsible for its preparation; and that I am licensed in the State of California as a civil engineer or electrical engineer, or I am a licensed architect. ❑ 1 affirm that I am eligible under the provisions of Division 3 of the Business and Professions Code by Section 5537.2 or 6737.3 to sign this document as the person responsible for its preparation; and that I am a licensed contractor performing this work. ❑ I affirm that I am eligible under the exemption to Division 3 of the Businessand rofessions Code to sign this document because it pertains to a structure or type of work described as exempt pursuant to Business and Pro ssions Code Sections 5537, 5538 and 6737.1. PRINCIPAL LIGHTING DESIGNER - NAME SIG DAT LIC. # Candice Noto Designs / LIGHTING MANDATORY MEASURES All Indicate location on plans of Note Block for Mandatory Measures LIGHTING COMPLIANCE FORMS & WORKSHEETS Check box if worksheet is included 1KLTG-1-C, Parts 1 of 4 and 2 of 4: Certificate of Compliance. Part 1 of 4 and 2 of 4 are required for all submittals ® LTG- 1-C, Part 3 of 4: Certificate of Compliance. Part 3 of 4 submittal is required only if Control Credits are claimed ®LTG -1-C, Part 4 of 4: Certificate of Compliance. Part 4 of 4 submittal is required when lighting controls are installed ®LTG -2-C: Indoor Lighting Schedule OLTG-3-C: Portable Lighting Worksheet ®LTG -4-C: Lighting Controls Credit Worksheet ®LTG -5-C: Indoor Lighting Power Allowance LTG -6-C: Tailored Method Worksheet TG -7-C: Room Cavity Ratio Worksheet LTG -8-C: Common Lighting Systems Method Worksheet C1 LTG -9-C: Line Voltage Track Lighting Worksheet EnergyPro 4.3 by EnergySoft User Number: 6712 Job Number: Page:3 of 16 Fr" L CERTIFICATE OF COMPLIANCE (Part 2 of 4) LTG -1 -C ROJECT NAME DATE Jumpin' Juice & Java Tenant Improvement I 1/3/2008 INSTALLED LIGHTING, CONDITIONED SPACES (From LTG -2-C) PORTABLE LIGHTING (From LTG -3-C) LIGHTING CONTROL CREDIT, CONDITIONED SPACES (From LTG -4-C) CONDITIONED SPACE ADJUSTED INSTALLED LIGHTING POWER INSTALLED LIGHTING, UNCONDITIONED SPACES (From LTG -2-C) LIGHTING CONTROL CREDIT, UNCONDITIONED SPACES (From LTG -4-C) UNCONDITIONED SPACE ADJUSTED INSTALLED LIGHTING POWER INSTALLED WATTS 1,673 0 11 1,662 0 0 0 ALLOWED INDOOR LIGHTING POWER FOR CONDITIONED SPACES ❑ COMPLETE BUILDING METHOD (From LTG -5-C) ALLOWED ❑X AREA CATEGORY METHOD (From LTG -5-C) WATTS ❑ TAILORED METHOD (From LTG -5-C) ALLOWED LIGHTING POWER 1,697 PERFORMANCE METHOD ❑ COMMMON LIGHTING SYSTEM (From LTG -8-C) ALLOWED INDOOR LIGHTING POWER FOR UNCONDITIONED SPACES From LTG -5-C) 0 MANDATORY INDOOR AND DAYLIGHTING AUTOMATIC CONTROLS CONTROL LOCATION (Room #) WE CONTROL IDENTIFICATION L._., e. CONTROL TYPE (Auto Time Switch, Dimming, etc.) SPACE CONTROLLED Check if NOTE TO FIELD NOTES TO FIELD - For Buildinq Department Use Only EnergyPro 4.3 by EnergySoft User Number: 6712 Job Number: Page:4 of 16 CERTIFICATE OF COMPLIANCE (Part 3 of 4) LTG -1 -C Is OJECT NAME DATE Jumpin' Juice & Java Tenant Improvement I 1/3/2008 CONTROL IDENTIFICATION CONTROLTYPE (OCCUDant. Davliaht. Dimmina. etc.) Occ Sensor - — 250 I EnergyPro 4.3 by EnergySoft User Number: 6712 Job Number: Page:5 of 16 1 i 4 CERTIFICATE OF COMPLIANCE (Part 4 of 4) LTG -1-C PROJECT NAME Jum in' Juice & Java Tenant Improvement DATE 1/3/2008 esigner: This form is to be used by the designer and attached to the plans. Listed below are all the acceptance tests for lighting systems. The designer is required to check the boxes by all acceptance tests that apply and list all equipment that require an acceptance test. If all equipment of a certain type requires a test, list the equipment description and the number of systems to be tested in parentheses. The NJ number designates the Section in the Appendix of the Nonresidential ACM Manual that describes the test. Also indicate the person responsible for performing the tests (i.e. the installing contractor, design professional or an agent selected by the owner). Since this form will be part of the plans, completion of this section will allow the responsible party to budget for the scope of work appropriately. Building Departments: Before an occupancy permit is granted for a newly constructed building or space, or a new lighting system system serving a building or space is operated for normal use,- all control devices serving the building or space shall be certified as meeting the Acceptance Requirements for Code Compliance. In addition a Certificate of Acceptance, LTG -1-A, Forms shall be submitted to the building department that: A. Certifies plans, specifications, installation certificates, and operating and maintenance information meet the requirements of§ 10-103(b) and Title 24 Part 6. Test Description Test Performed By: D LTG -2-A: Lighting Control Acceptance Document - Occupancy Sensor Acceptance - Manual Daylight Controls Acceptance - Automatic Time Switch Control Acceptance lir �� ��,t Equipment requiring acceptance testing -H Nn LOU ©C& S &� O LTG -3-A: Automatic Daylighting Controls Acceptance Document Equipment requiring acceptance testing EnergyPro 4.3 by EnergySoft User Number: 6712 Job Number: Page:6 of 16 1 INDOOR LIGHTING SCHEDULE (Part 1 of 2) LTG -2-C ROJECT NAME DATE Jumpin' Juice & Java Tenant Improvement 1/3/2008 INSTALLED LIGHTING POWER FOR CONDITIONED SPACES r L Luminaire Lamps/Ballasts Installed Watts C D E F G H I J Name Type Description pori v3 V CSC 333 �Nv �.� ry N O mv� 3m� N CdC 3•v3 9^v �•� D N O C 3�� ���_ N N (p O CD �m 'J r C Z 3• div nl (D w j x�m (n CD O. No A�4ec ft Fluorescent T8 Energy Savings F32T8 4 30 1.0 104.0 X 6 624 C Fec ft Fluorescent T8 Energy Savings 2 30 1.0 54.0 X 1 54 D 2) 26w Compact Fluorescent Triple 4 Pin FTR26W/GX24 -3 2 26 1.0 55.0 X 7 385 E P) 13w ( lec3w Compact Fluorescent Triple 4 Pin FM 13W/GX24 -1 1 13 1.0 14.0 X 5 70 F 75w Low Voltage Halogen 1 75 1.0 80.0 X 3 240 G 100w Surface Mount Incandescent 1 00W 1 100 1 MG 3 300 i r PAGE TOTAL 1 673 t BUILDING TOTAL (sum of all pages) 1 ,673 PORTABLE LIGHTING (From LTG -3-C) D CONTROL CREDIT (From LTG -4-C) 11 ADJUSTED ACTUAL WATTS 1 662 EnergyPro 4.3 by EnergySoft User Number: 6712 Job Number: Page:7 of 16 1 LIGHTING CONTROLS CREDIT WORKSHEET (Part 1 of 2) LTG -4-C CONTROL CREDITS FOR CONDITIONED SPACES OJECT NAME DATE Jum 6n' Juice & Java Tenant Improvement 1/3/2008 A B C D E F G H I J ROOM # ZONE ID CONDITIONED AREAS LIGHTING CONTROL DESCRIPTION PLAN REF. ROOM AREA (SF) DAYLIGHTING WATTS OF CONTROL LIGHTING LIGHTING ADJUST. FACTOR' CONTROL CREDIT WATTS (H X 1) WINDOW WALL RATIO GLAZING VLT SKYLIGHT EFFECTIVE APERTURE' Restroom Occ Sensor ft �— 250 C 58 54 0.20 11 1) From Equation 146-A 2) From Table 146-A PAGE TOTAL 11 BUILDING TOTAL 11 Enter in LTG -2-C: Lighting Control Credit 1 EnergyPro 4.3 by EnergySoft User Number: 6712 Job Number: Page:8 of 16 1 INDOOR LIGHTING POWER ALLOWANCE LTG -s -C OJECT NAME Jum in'Juice & Java Tenant Im rovement kLL DATE 1/3/2008 LOWED LIGHTING P WER Choose One Metho COMPLETE BUILDING METHOD - CONDITIONED SPACES ALLOWED WATTS WATTS PER SF COMPLETE BLDG. AREA ALLOWED WATTS BUILDING CATEGORY (From Section 146 Table 146-B) AREA CATEGORY METHOD - CONDITIONED SPACES AREA (SF) ALLOWED WATTS AREA CATEGORY (From Section 146 Table 146-C) WATTS PER SF All Others 0.60 431 259 Retail Sales Wholesale 1.70 478 813 Kitchen Food Preparation 1.60 391 626 D AREA D WATTS TAILORED METHOD - UNCONDITIONED SPACES • r 0 O EnergyPro 4.3 by EnergySoft User Number: 6712 Job Number: Page:9 of 16 ' PAGE TOTAL BUILDING TOTAL 1 , 300 1, 697 1 ,300 AREA 1 ,697 WATTS TAILORED METHOD - CONDITIONED SPACES TOTAL ALLOWED WATTS D (From LTG -6-C or from computer run.) 4 UNCONDITIONED SPACES Complete Building and Area Catagory Methods Category (From Section'146 Table 146 -B&C) WATTS PER SF AREA (SF) ALLOWED WATTS PAGE TOTAL BUILDING TOTAL D D D AREA D WATTS TAILORED METHOD - UNCONDITIONED SPACES TOTAL UNCONDITIONED SPACES ALLOWED WATTS (From LTG -5-C and LTG -6-C) 0 O EnergyPro 4.3 by EnergySoft User Number: 6712 Job Number: Page:9 of 16 ROOM CAVITY RATIO WORKSHEET (RCR>=3.5) LTG -7-C PROJECT NAME jumping JUICe & Java Tenant Improvement FORENFORCEMENTAGENCY USE ONLY CUMENTATION AUTHOR DATE 1/3/2008 PLAN CHECK BY DATE RECTANGULAR SPACES A B C D E F Room Name Task/Activity Description Room Length (L) ft Room Width (W) ft Room Cavity Height (H) (ft) Room Cay. Ratio 5xHx(L+W) /(LxW) NON-RECTAN ULAR SPACES A B C D E F Room Name Task/Activity Description Room Area (A) (so Room Perimeter (P) (ft) Room Cavity Height (H) (ft) Room Cay. Ratio 2.5 x H x P /A EnergyPro 4.3 by Energysoft User Number: 6712 Job Number: Page: 10 of 16 LIGHTING MANDATORY MEASURES LTG -MM &OJECT NAMEJumpiDATE n' Juice & Java Tenant Improvement 1/3/2008 4 4 DESCRIPTION Designer Enforcement §131(d)1 For every floor, all interior lighting systems shall be equipped with a separate automatic control to shut off the lighting. This automatic control shall meet the requirements of Section 119 and may be an occupancy sensor, automatic time switch, or other device capable of automatically shutting off the lighting. X] §131(d)2Override for Building Lighting Shut-off: The automatic building shut-off system is provided with a manual, accessible override switch in sight of the lights. The area of override is not to exceed 5,000 square feet. X❑ §119(h) Automatic Control Devices Certified: All automatic control devices specified are certified, all alternate equipment shall be certified and installed as directed by the manufacturer. X❑ §111 w Fluorescent Ballast and Luminaires Certified: All fluorescent fixtures specified for the project are certified and listed in the Directory. All installed fixtures shall be certified. X] §132 Tandem Wiring for One and Three Lamp Fluorescent Fixtures: All one and three lamp fluorescent fixtures are tandem wired with two lamp ballasts where required by Standards Section 132; or all one and three lamp fluorescent fixtures are specified with electronic high -frequency ballasts and are exempt from tandem wiring requirements. X❑ §131(a) Individual Room/Area Controls: Each room and area in this building is equipped with a separate switch or occupancy sensor device for each area with floor -to - ceiling walls. X❑ §131(b) Uniform Reduction for Individual Rooms: All rooms and areas greater than 100 square feet and more than 0.8 watts per square foot of lighting load shall be controlled with bi-level switching for uniform reduction of lighting within the room. ❑ §131(c) Daylight Area Control: All rooms with windows and skylights that are greater than 250 square feet and that allow for the effective use of daylight in the area shall have 50% of the lamps in each daylit area controlled by a separate switch; or the effective use of daylight cannot be accomplished because the windows are continuously shaded by a building on the adjacent lot. Diagram of shading during different times of the year is included on plans. §131(e) Display Lighting. Display lighting shall be separately switched on circuits that are 20 amps or less. EnergyPro 4.3 by EnergySoft User Number: 6712 Job Number: Page: 11 of 16 CERTIFICATE OF COMPLIANCE (Part 1 of 2) MECH-1-C PROJECT NAME DATE OF PLANS DATE Jum in' Juice & Java Tenant Improvement 1/3/2008 OJECT ADDRESS BUILDING TYPE NONRESIDENTIAL ❑ HIGH RISE RESIDENTIAL ❑ HOTEL/MOTEL GUEST ROOM PHASE OF CONSTRUCTION ❑X NEW CONSTRUCTION ❑ ADDITION ❑ ALTERATION ❑ UNCONDITIONED (File Affidavit) 79-485 Highway 111, Suite 8 La Quinta COMPLIANCE PROOF OF ENVELOPE COMPLIANCE ❑ PREVIOUS ENVELOPE PERMIT ❑ ENVELOPE COMPLIANCE ATTACHED PRINCIPAL DESIGNER - MECHANICAL TELEPHONE Building Permit # Scott Design and Title 24 (760) 200-4780 SIGNAT DOCUMENTATION AUTHOR TELEPHONE Checked by/Date Scott Design & Title 24 (760) 200-4780 Enforcement Agency GENERAL INFORMATION DATE OF PLANS BUILDING CONDITIONED FLOOR AREAONE 7` 1,300Sq.Ft.7 15 BUILDING TYPE NONRESIDENTIAL ❑ HIGH RISE RESIDENTIAL ❑ HOTEL/MOTEL GUEST ROOM PHASE OF CONSTRUCTION ❑X NEW CONSTRUCTION ❑ ADDITION ❑ ALTERATION ❑ UNCONDITIONED (File Affidavit) METHOD OF MECHANICAL ® PRESCRIPTIVE ❑ PERFORMANCE COMPLIANCE PROOF OF ENVELOPE COMPLIANCE ❑ PREVIOUS ENVELOPE PERMIT ❑ ENVELOPE COMPLIANCE ATTACHED STATEMENT OF COMPLIANCE This Certificate of Compliance lists the building features and performance specifications needed to comply with Title 24, Parts 1 and 6 of the California Code of Regulations. This certificate applies only to building mechanical requirements. The documentation preparer hereby certifies that the documentation is accurate and complete. DOCUMENTATION AUTHOR SIGNAT DAE Tim Scott i9 The Principal Mechanical Designer hereby certifies that the proposed building design represented in this set of constr tion documents is consistent with the other compliance forms and worksheets, with the specifications, and with any other Iculations submitted with this permit application. The proposed building has been designed to meet the mechanical quirements contained in the applicable parts of Sections 100, 101, 102, 110 through115, 120 through 125, 142, 144, and 145. ❑ The plans & specifications meet the requirements of Part 1 (Sections 10-103a). ❑ The installation certificates meet the requirements of Part 1 (10-103a 3). ❑ The operation & maintenance information meets the requirements of Part 1 (10-103c). Please check one: (These sectionsof the Business and Professions Code are printed in full in the Nonresidential Manual.) ❑ I hereby affirm that I am eligible under the provisions of Division 3 of the Business and Professions Code to sign this document as the person responsible for its preparation; and that I am licensed in the State of California as a civil engineer, or mechanical engineer or I am a licensed architect. ❑ I affirm that I am eligible under the exemption to Division 3 of the Business and Professions Code by Section 5537.2 or 6737.3 to sign this document as the person responsible for its preparation; and that I am a licensed contractor performing this work. ❑ I affirm that I am eligible under the exemption to Division 3 of the Business and Professions Code to sign this document because it pertains to a structure or type of work described pursuant to Business and Professions Code sections 5537, 5538, and 6737.1. PRINCIPAL MECHANICAL DESIGNER - NAME Scott Design and Title 24 SIGNATURE DATE LIC. # INSTRUCTIONS TO APPLICANT ® MECH-1-C: Certificate of Compliance. Part 1, 2, 3 of 3 are required on plans for all submittals. ❑ MECH-2-C: Air/Water/Service/Water Pools Requirements. Part 1 of 3, 2 of 3, 3 of 3 are required for all submittals, but may be on plans. ❑ MECH-3-C: Mechanical Ventilation and Reheat is required for all submittals with mechanical ventilation, but may be on plans. MECH-4-C: HVAC Misc. Prescriptive Requirements is required for all prescriptive submittals, but may be on plans. ❑ MECH-5-C: Mechanical Equipment Details are required for all performance submittals. EnergyPro 4.3 by EnergySoft User Number: 6712 Job Number: Page: 12 of 16 4 4 CERTIFICATE OF COMPLIANCE (Part 2 of 2) MECH-1-C PROJECT NAME DATE h Jumpin' Juice & Java Tenant Improvement 1 1/3/2008 vesigner: This form is to be used by the designer and attached to the plans. Listed below are all the acceptance tests for mechanical systems. The designer is required to check the boxes by all acceptance tests that apply and list all equipment that requires an acceptance test. If all equipment of a certain type requires a test, list the equipment description and the number of systems to be tested in parentheses. The NJ number designates the Section in the Appendix of the Nonresidential ACM Manual that describes the test. Also indicate the person responsible for performing the tests (i.e. the installing contractor, design professional or an agent selected by the owner). Since this form will be part of the plans, completion of this section will allow the responsible party to budget for the scope of work appropriately. Building Departments: SYSTEM ACCEPTANCE. Before an occupancy permit is granted for a newly constructed building or space, or a new space -conditioning system serving a building or space is operated for normal use, all control devices serving the building or space shall be certified as meeting the Acceptance Requirements for Code Compliance. In addition a Certificate of Acceptance, MECH-1-A Form shall be submitted to the building department that certifies plans, specifications, installation certificates, and operatinq and maintenance information meet the requirements of Section 10-103(b) and Title 24 Part 6. STATEMENT OF COMPLIANCE ❑ MECH-2-A: Ventilation System Acceptance Document -Variable Air Volume Systems Outdoor Air Acceptance -Constant Air Volume Systems Outdoor Air Acceptance Equipment requiring acceptance testing Test required on all New systems both New Construction and Retrofit. ❑ MECH-3-A: Packaged HVAC Systems Acceptance Document Equipment requiring acceptance testing Test required on all New systems both New Construction and Retrofit. MECH-4-A: Air -Side Economizer Acceptance Document Equipment requiring acceptance testing Test required on all New systems both New Construction and Retrofit. Units with economizers that are installed at the factory and certified with the commission do not require equipment testing but do require construction inspection. ❑ MECH-5-A: Air Distribution Acceptance Document Equipment requiring acceptance testing This test required If the unit serves 5,000 V of space or less and 25% or more of the ducts are in noncondifioned or semiconditioned space like an attic. New systems that meet the above requirements. Retrofit systems that meet the above requirements and either extend ducts, replace ducts or replace the packaged unit. ❑ MECH-6-A: Demand Control Ventilation Acceptance Document Equipment requiring acceptance testing All new DCV controls installed on new or existing packaged systems must be tested. ❑ MECH-7-A: Supply Fan Variable Flow Control Acceptance Document Equipment requiring acceptance testing All new VA fan volume controls installed on new or existing systems must be tested ❑ MECH-8-A: -Hydronic System Control Acceptance Document -Variable Flow Controls Applies to chilled and hot water systems. -Automatic Isolation Controls Applies to new boilers and chillers and the primary pumps are connected to a common header. -Supply Water Temperature Reset Controls Applies to new constant flow chilled and hot water systems that have a design capacity greater than or equal to 500,000 Btu/hr. -Water-loop Heat Pump Controls Applies to all new watedoop heat pump systems where the combined loop pumps are greater than 5 hp. -Variable Frequency Controls Applies to all new distribution pumps on new variable Bow chilled, hydronic heat pump or condenser water systems where the pumps motors are greater than 5 hp. Equipment re uirin acceptance testing EnergyPro 4.3 by EnergySoft User Number: 6712 Job Number: Page:13 of 16 MECHANICAL MANDATORY MEASURES Part 1 of 2 MECH-MM PROJECT NAME DATE Jum in' Juice & Java Tenant Improvement 1/3/2008 DESCRIPTION Designer Enforcement Equipment and Systems Efficiencies FX-] §11 Any appliance for which there is a California standard established in the Appliance Efficiency Regulations will comply with the applicable standard. 0 §115(a) Fan type central furnaces shall not have a pilot light. §123 Piping, except that conveying fluids at temperatures between 60 and 105 degrees Fahrenheit, or within HVAC equipment, shall be insulated in accordance with Standards Section 123. §124 Air handling duct systems shall be installed and insulated in compliance with Sections 601, 602, 603, 604, and 605 of the 2001 CMC Standards. Controls §122(e) Each space conditioning system shall be installed with one of the following: §122(e)1A Each space conditioning system serving building types such as offices and manufacturing facilities (and all others not explicitly exempt from the requirements of Section 112 (d)) shall be installed with an automatic time switch with an accessible manual override that allows operation of the system during off -hours for up to 4 hours. The time switch shall be capable of programming different schedules for weekdays and weekends and have program backup capabilities that prevent the loss of the device's program and time setting for at least 10 hours if power is interrupted; or §122(e)1 g An occupancy sensor to control the operating period of the system; or FEI§1 22(e)1 C A 4 -hour timer that can be manually operated to control the operating period of the system. §I22(e)2 Each space conditioning system shall be installed with controls that temporarily restart and temporarily operate the system as required to maintain a setback heating and/or a setup cooling thermostat setpoint. F] §122(g) Each space conditioning system serving multiple zones with a combined conditioned floor area more than 25,000 square feet shall be provided with isolation zones. Each zone: shall not exceed 25,000 square feet; shall be provided with isolation devices, such as valves or dampers, that allow the supply of heating or cooling to be setback or shut off independently of other isolation areas; and shall be controlled by a time control device as described above. ® §I22(a&b) Each space conditioning system shall be controlled by an individual thermostat that responds to temperature within the zone. Where used to control heating, the control shall be adjustable down to 55 degrees F or lower. For cooling, the control shall be adjustable up to 65 degrees F or higher. Where used for both heating and cooling, the control shall be capable of providing a deadband of at least 5 degrees F within which the supply of heating and cooling is shut off or reduced to a minimum. FX §1 §122(c) Thermostats shall have numeric setpoints in degrees Fahrenheit (F) and adjustable setpoint stops accessible only to authorized personnel. §112(b) Heat pumps shall be installed with controls to prevent electric resistance supplementary heater operation when the heating load can be met by the heat pump alone. EnergyPro 4.3 by EnergySoft User Number: 6712 Job Number: Page: 14 of 16 MECHANICAL MANDATORY MEASURES Part 2 of 2 MECH-MM NAME JumDin' Juice & Java Tenant Improvement DATE 1/3/2008 Description Designer Enforcement Ventilation F§121(e) Controls shall be provided to allow outside air dampers or devices to be operated at the ventilation rates as specified on these plans. ❑ §122(f) Gravity or automatic dampers interlocked and closed on fan shutdown shall be provided on the outside air intakes and discharges of all space conditioning and exhaust systems. X §144(f) All gravity ventilating systems shall be provided with automatic or readily accessible manually operated dampers in all openings to the outside, except for combustion air openings. ❑ §121(f)1 Air Balancing: The system shall be balanced in accordance with the National Environmental Balancing Bureau (NEBB) Procedural Standards (1983), or Associated Air Balance Council (AABC) National Standards (1989); or ❑ §121(f)2 Outside Air Certification: The system shall provide the minimum outside air as shown on the mechanical drawings, and shall be measured and certified by the installing licensed C-20 mechanical contractor and certified by (1) the design mechanical engineer, (2) the installing licenced C-20 mechanical contractor; or (3) the person with overall responsibility for the design of the ventilation system; or §I21(f)3 Outside Air Measurement: The system shall be equipped with a calibrated local or remote device capable of measuring the quantity of outside air on a continuous basis and displaying that quantity on a readily accessible display divice; or §121(f)4 Another method approved by the Commission. Service Water Heating Systems ❑ §113(b)2 if a circulating hot water system is installed, it shall have a control capable of automatically turning off the circulating pump(s) when hot water is not required. §113(c) Lavatories in restrooms of public facilities shall be equipped with controls to limit the outlet temperature to 110 degrees F. EnergyPro 4.3 by EnergySoft User. Number: 6712 Job Number: Page:15 of 16 LIGHTING INSPECTION CHECKLIST LTG -I NAME INSPECTION DATE Jumpin' Juice & Java Tenant Improvement 1 1/3/2008 FIXTURE CODE TYPE DESCRIPTION LAMP TYPE LAMP QUANT. NUMBER OF FIXTURES WATTS PER FIXTURE FIELD NOTES A 4 4 ft Fluorescent T8 Energy Savings Elec F32T8 4 6 104.0 C 2 4 ft Fluorescent T8 Energy Savings Elec F32T8 2 1 54.0 D 2 26w Compact Fluorescent Triple 4 Pin Elec 2 7 55.0 E 1 13w Compact Fluorescent Triple 4 Pin Elec CFM 1 5 14.0 F 75w Low Voltage Halogen Watt 1 3 80.0 G 100w Surface Mount Incandescent 775 yaw 1 3 100.0 t J EnergyPro 4.3 by EnergySoft User Number: 6712 Job Number: Paoe:16 of 16 1