07-2285 (RER)P.O. BOX 1504 78-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 Application Number: -07 =00002285 Property Address: 79099 LIGA APN: 772-130-073- - Application description: REMODEL - RESIDENTIAL Property Zoning: LOW DENSITY RESIDENTIAL Application valuation: 10000 Applicant: Architect or Engineer Cab �Z BUILDING & SAFETY DEPARTMENT BUILDING PERMIT LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7 00) of Division 3 of the Busine S and Professionals Code, and my License is in full force and effect. License Cas B is o.: 788530 �- Date:O�( ontractorv OWNER -BU LDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the following reason (Sec. 7031 .5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: (_) I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered.for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). (_ 1 1, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). (_ I I am exempt under Sec. , B.&P.C. for this reason _ Date: Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Name: _ Lender's Address: LQPERi1IIT Owner: ZATOPA RESIDENCE 2500 RALSTON AVE HILLSBOROUGH, CA BURLINGAME, CA 94010 Contractor: SUNTERRA BUILDERS 78920 STARLIGHT LANE " BERMUDA DUNES, CA 922 (760)702-5772 Lic. No.: 788530 VOICE (760) 777-7012 FAX (760) 777-7011 INSPECTIONS (760) 777-7153 Date: 9/18/07 WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: I have and will maintain a certificate of consent to self -insure for,workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. I have and will maintain workers' compensation insurance, as required bySection 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier EXEMPT Policy Number EXEMPT I certify that, in the performance of the work for which this -permit is issued, I shall not employ any person in any mann r so as to become subject to the workers' compensation laws of California, an agree that, if I s Id ecome subject to the wor rs' compensation provisions of Section 3 0 of the Labor Cad I shall forthwit p it se provisions. � r Date: Applicant: WAR IN : FAILURE TO SECUR RKERS' COMPENSATI N COVERAGE IS UNLAWFUL, AND SHALL SUBJEC AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000) IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT. IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the conditions and restrictions set forth on this application. 1. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application, the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that thea ve information is correct. I agree to comply with all city and count ordantes and state laws relating to ti, construction, and hereby th a epresentatives of this cco�un toe Per upon the above-mentioned prope or inspection o Date: / V nature (Applicant or Agentl: ` LQPERMIT Application Number . . . . . 07-00002285 ------ Structure Information EXISTING RESIDENCE ----- Other struct info CODE EDITION 2001 CBC # BEDROOMS ---------------------------------------------------------------------------- .00 Permit . . . BUILDING PERMIT Additional desc . Permit Fee . . . . 117.00 Plan Check Fee 76.05 Issue Date . . . . Valuation . . . . 10000 Expiration Date 3/16/08 Qty Unit Charge Per Extension BASE FEE 45.00 " .8.00 9.0000 THOU BLDG 2,001-25,000 72.00 Permit MECHANICAL Additional desc . Permit Fee . . . . 26.00 Plan Check Fee 6.50 Issue Date Valuation . . . . 0 Expiration Date 3/16/08 Qty Unit Charge Per Extension BASE FEE 15.00 1.00 11.0000 EA MECH DOMESTIC.INCINERATOR 11.00 ---------- - - --------------------- Special Notes and Comments --------- FIREPLACE ADDITION TO EXISTING CASITA. 2001 CBC, CMC. ---------------------------------------------------------------------------- Other Fees . . . . . . . . . STRONG MOTION (SMI) - ZES 1.00 Fee summary Charged Paid Credited ---------------------------------------- Due ----------------- Permit Fee Total 143.00 .00 .00 143.00 Plan Check Total 82.55 .00 .00 82.55 Other Fee Total 1.00 .00 .00 1.00 Grand Total 226.55 .00 .00 226.55 LQPERMIT Bin # City of La Quinta l JA -.PK-- Building & Safety Division r P.O. Box 1504, 78-495 Calle Tampicov` 2 La Quinta, CA 92253 - (760) 777-701"2 Building Permit Application and Tracking Sheet Permit # Project Address: 41 gig Owner's Name: A. A. P. Number: Address: Legal Description: Contractor vjL49E C City, ST, Zip: �d /0(/ Telephone: Address: 7 ^q?,® I ". D-4 Project Description: City, -ST, Zip: elf%A OVljE7 S CA IZ20 Telephone: Y State Lic. # : City Lic. #: '03 Arch., Engr., Designer: N Address: City,. ST, Zip: 4/ U// f Telephone: . 77 �/ IL State Lic. #: G Name of Contact Person: ���� Construction Type: Occupancy: /moo Project type (circle one): New Add'n Alter Repair Demo �#Stories: #Units:q. . Telephone # of Contact Person: 'rl S70 Estimated Value'of Project: 0, APPLICANT: DO NOT WRITE BELOW THIS LINE # Submittal Req'd - Rec'd TRACKING. " PERMIT FEES Plan Sets' Plan Check submitted Item Amount Structural Calcs. Reviewed, ready'for corrections 8' 22 Plan Check Deposit Truss Calcs. Called Contact Person y Plan Check Balance Energy Calcs. Plans picked up Construction Flood plain plan Plans resubmitted Mechanical Grading plan 2nd Review, ready for correctio s/issue Electrical Subcontactor List Called Contact Person In 100, Plumbing Grant Deed Plans picked up S.M.I. H.O.A. Approval Plans resubmitted Grading IN HOUSE:- '"' Review, ready for corrections/issue Developer Impact Fee Planning Approval Called Contact Person A.I.P.P. Pub. Wks. Appr Date of permit issue School Fees Total Permit Fees R 09/14/2007 11:09. 7603469997'x' ,►r T �' c ITR J)CATION COURSE HOMEOWNERS ASSOC September 6. 2007 Mr. and Mrs. ,Alan Zatopa 2900 Ralston Ave. Hills Borough, CA 94010 RE: Architectural Approval Request 79099 Liga Dear Mr.. and Mrs. Zatopa, The members of the Architectural Committee have reviewed your application and plan submitted for the addition of a fireplace to your casita and grant approval to that project. Enclosed please find a 'Notice of m P� iW can p ust be their alb eti when the . sued project is complete so that the Co Should you have any questions please do not hesitate to contact our office. Sincerely, On behalf of the Citrus Course HOA Architecbural Committee Maryann Hoss Assistant Association Manager P.O. Box 129200811» Desert, CA 92255 - 75061 Mediterranean, Suite 8, Palm Desert. California 760.3469000 - FAX 760.346.9997 • www.citruscoursehae.con1 CITY OF LA QUINTA §Y§, -CONTRACTOR LIST A JOB ADDRESS ® PERMIT NUMBER a-7— J OWNER ,.. _BUILDER S� This form shall be posted on the fob with the Building Inspection Card at all times in a conspicuous place.. Only persons appearing on this list or their employees are authorized to work on this job. Any changes to this list must be approved by the Building Division prior to commencement of work. Failure to comply will result in a stoppage of work and/or the voidance. of building permit. For each applicable trade, all information requested below must be.completed by applicant. "Un tile" is not an acceptanie response. F ■11111111110 WKEW W NVE FIF04 " I. Alto A. 15OKERN FIREPLACE AND CHIMNEY SYSTEMS, NORTH AMEIRICAN DISTRIBUTION BY EARTHCORE INDUSTRIES, INC., JACKSONVILLE, FLORIDA (TELEPHONE 500-642-21120). 11. FROMT VEWAIMOK A. MODULAR REFRACTORY MA50NRY PRECAST FIREPLACE AND CHIMNEY COMPONENTS. 1. DE-516NED FOR FIELD A55EMBLY A5 A FIREPLACE AND CHIMNEY UNIT. 2. ALL INTERLOGKIN6 PARTS NECESSARY FOR ASSEMBLY OF A COMPLETE FIREBOX AND SMOKE DOME. 5. INTERLOGKIN6 DOUBLE MODULE CHIMNEY COMPONENTS. III. MATERIAL -en A. L16HT WEIGHT CONCRETE OFA PROPRIETARY MIXTURE OF ICELANDIC VOLCANIC, PUMICE A66RESATE AND ALUMINATE CEMENT FOR PRECAST FIREBOX, CHIMNEY BLOCK AND FLUE LINER COMPONENTS. 1. COMPRESSIVE STRENGTH: FIREBOX AND CHIMNEY BLOCK: 1112 P51. 2. COMPRESSIVE 5T17EN6'M: FLUE LINER: 1115 P51. 5" PREMIXED (DRY) 15OKERN LIP MORTAR, MASONRY ADHESIVE. 1. TENSILE STRENGTH: 601 P51; COMPRESSIVE STRENGTH: 2460 P51. 2. ASTM 46261T. G. STANDARD 1 1/8" HIGH TEMPERATURE REFRACTORY BRICK TO LINE FIREBOX INTERIOR D. STANDARD CAST IRON POKER -STYLE DAMPER (OPTIONAL TOP MOW DAMPER). W. INSTALLAT06 A. REFERENCE MANUFACTURERS INSTALLATION INSTRUCTIONS FOR STANDARD CONFIGURATIONS,,*EIGHTS, SIZES AND INSTALLATION DETAILS. B. SUITABLE MASONRY FOJNDA71ON AND NONCOMBUSTIBLE HEARTH EXTENSION MAST BE PROVIDED. G. UNIT TO BE A55EMBLED ON 51TE PER MANUFACTURER'S ILLUSTRATED INSTRUCTIONS. I. PREMIXED 15OKERN LIP MORTAR 15 U5ED AT ALL .JOINTS BET161EEN COMPONENTS. 2. FIREBOX TO BE LINED WITH MINIMUM 1116' RATED FIRE BRICK. D. STANDARD FIREPLACE AND CHIMNEY UNITS L15TED FOR 'ZERO CLEARANCE" TO UUNINSULATEDU W00D FRAMING MEMBERS. V. GERTIf�G/►TIOM4 A. AARNOCK HERSEY/1NTERTEK TE5TING SERVICES REPORT NO. 652A12500. B. MEETS OR EXCEEDS U.L. 105HT; U.L. 121-1111; U.L. I"M; U.L.G. 5610; ANSI 2.11. M. CODE 000 PI.IANGE: A. LOB.0. NO. 501-1 / SBGU NO. gb2b / MEA N.Y.G. 241-40-E. IWKM FIFMAGE AND Wit -W 9IW..1PI6ATI0Nm RIS INSULATED STEEL CHIMNEY (U L. REPORT # 105HT) STAINLESS STEEL ANCHOR PLATE BY CHIMNEY MANUFACTURER 3/8" ANCHOR BOLT5 REFRACTORY CEMENT - MASONRY FIREPLACE OWKERN) 4. f: INSTALL ALL CHIMNEY COMPONENTS PER MANUFACTURE'S INSTRUCTIONS IRP. CHIMNEY TRAM noN VENT GAP PER MANUF, SPEOS 6.1. METAL OAP 6.1. FLA5HIN6 AND COUNTER FLASHING AND SEALANT SLOPE TO 2X10 TRIM W/ DRAIN 5TUCCO OVER "SUPER .NMBO-TEX" CO MIN. PAPER GOVT. EXTERIOR STUCCO 2X EXT STUDS FLUE PROVIDE MANUFACTURE APPROVED SPARK ARRESTOR. SCALE: 1" = 1'_0" CHIMNEYS ATTACHED TO ANY APPLIANCE OR FIREPLACE THAT BURIALS SOLID FUEL SHALL BE EQUIPPED WITH AN APPROVED SPARK ARRESTER. THE NET FREE AREA OF THE SPARK ARRESTER SHALL NOT BE LESS THAN FOUR TIMES THE NET FREE AREA OF THE OUTLET OF THE CHIMNEY. THE SPARK ARRESTER SCREEN SHALL HAVE HEAT AND CORROSION RE515TANCE EQUIVALENT TO 0.109" (NO. 12 B.W. 6A6E) WIRE, 0.042" No. 14 B.W. 6A6E) 6ALVANIZED WIRE OR 0.022" (NO. 24 B.W. 6A&E) STAINLESS STEEL. OPENIN65 SHALL NOT PERMIT THE PASSA6E OF SPHERES HAVIN6 A DIAMETER LAR6ER THAN 1/2" AND SHALL NOT BLOCK THE PASSAGE OF 5PHERE5 HAVIN6 A DIAMETER OF LESS THAN 5/6". CAN LltlmjT EEI:, •' q) SWELVING -INTERIOR ELtiATIOR 11 1 G.I. C[41CAP W/ I.C.B.O. APPROVED SPARK AWESTOR. PROVIDED BY FIREPLACE MANLIFACTURE32. 2X4 W/ STUCCO O/ Q ev RIGHT L VATI 0 SCALE: 1/4" = V-0" G.I. CHIK44EY CAP W1 I.C.B.O. APPROVED SPARK ARRESTOR. ENVY REAR ELEVATION 12._0 SCALE: 1 /4" = 1'— A;�QD SURFACE GUEST SUITE P12OVIDED BY F91253LACE MANUFACTURER. 2X4 W/ STUCCO 0/ Q t LEFT ELEVATION SCALE: 1/4" = 1'-0" G.I. CHINIsEY CAP W/ I.C.B.O. APPROVED SPARK ARRESTOR. =_- PROVIDED BY FIREPLACE AC . 2X4 W/ STUCCO 0/ -- - - 4 --------------- N FRONT ELEVATION SCALE: 1/4" = 1'-0" Fggtj���� HALL_ 10'-0" CL' G ffvffr.l 9'-0' CL' G R1 -, N�t I. --= I I 4 1 OW A I I XISTING CAS11A VERIFY LOCATION OF SMOKE DETECTOR P_ FRONT SIM -9014 5 I �� QIEST NON-GOM5Z 5722 nBLE ! HEARV - REAVILY 10°-0" G, DISTINWISHASLE FROM j FLOOR NDING / ADJACENT .7. 1 ril II �}g i 6X8 N 6)*BOTT T 50ii®� AT b' -O' I 5LOGCINS 8'-O" STRONG -TIE STRAP I FRAMING 850TTOM AT c0 tpW LEACH �ll�.D B1 LOOKIN6 - + TF}'1 \ 1� L. ,A LW I ! 25'-4' 5'MM I 7 I — — — — — — — — — — — 6"X 24" ISOKERN FIREPLACE. PROVIDE LARGE CROWN CAP AND SPARK ARRESTOR / RAIN CAP. I.C.B.O. NO. 5017. 6X8 COMBUSTIBLE MATERIALS SHALL NOT BE PLACED WITHIN 6" (152mm) OF TTOM AT THE FIREPLACE OPENING. NO SUCH MATERIAL WITHIN 12" (305mm) OF THE 2'-4' 5'-4' 2'-4' g""0" VV FIREPLACE OPENING SHALL PROJECT MORE THEN 1/8" (3mm) FOR EACH 1' N (25mm) CLEARANCE FROM SUCH OPENING. CBC SECTION 3102.7.8 101-0" COMBUSTIBLE MATERIALS SHALL NOT BE PLACED WITHIN 6" (152mm) OF -- THE FIREPLACE OPENING. NO SUCH MATERIAL WITHIN 12" (305mm) OF THE FIREPLACE OPENING SHALL PROJECT MORE THEN 1/8" (3mm) FOR EACH 1' (25mm) CLEARANCE FROM SUCH OPENING. CBC SECTION 3102.7.8 MANUFACTURERS SPECIFICATIONS). FL1313R PLAN / SITE PLAN DEMO SCALE: 1/411 = II_011 u 4 NEA CHIMNEY SCALE: 1/811 = V-011 A A SEP 0 4 2907 BUILDING CODES.' 2001 GALf1=0RN1A BU1LL71N6 CODE (G130) 2001 CALIFORNIA MECHANICAL GODS (CMG) 2001 CALIFORNIA PLUME3IN6 GODS (CPG) 2004 CALIFORNIA ELECTRICAL GODS: (CEG) 2001 GaL1i=ORNIA FIRE: CODE (CFC) `zo& 20035 CALIFORNIA ENERGY CODE (T24 ) L 00) WIM Jim AND ELEVATION OF CTION • 4 qW T -q 1/6' 4 glib' 6� R WKEW W NVE FIF04 " I. Alto A. 15OKERN FIREPLACE AND CHIMNEY SYSTEMS, NORTH AMEIRICAN DISTRIBUTION BY EARTHCORE INDUSTRIES, INC., JACKSONVILLE, FLORIDA (TELEPHONE 500-642-21120). 11. FROMT VEWAIMOK A. MODULAR REFRACTORY MA50NRY PRECAST FIREPLACE AND CHIMNEY COMPONENTS. 1. DE-516NED FOR FIELD A55EMBLY A5 A FIREPLACE AND CHIMNEY UNIT. 2. ALL INTERLOGKIN6 PARTS NECESSARY FOR ASSEMBLY OF A COMPLETE FIREBOX AND SMOKE DOME. 5. INTERLOGKIN6 DOUBLE MODULE CHIMNEY COMPONENTS. III. MATERIAL -en A. L16HT WEIGHT CONCRETE OFA PROPRIETARY MIXTURE OF ICELANDIC VOLCANIC, PUMICE A66RESATE AND ALUMINATE CEMENT FOR PRECAST FIREBOX, CHIMNEY BLOCK AND FLUE LINER COMPONENTS. 1. COMPRESSIVE STRENGTH: FIREBOX AND CHIMNEY BLOCK: 1112 P51. 2. COMPRESSIVE 5T17EN6'M: FLUE LINER: 1115 P51. 5" PREMIXED (DRY) 15OKERN LIP MORTAR, MASONRY ADHESIVE. 1. TENSILE STRENGTH: 601 P51; COMPRESSIVE STRENGTH: 2460 P51. 2. ASTM 46261T. G. STANDARD 1 1/8" HIGH TEMPERATURE REFRACTORY BRICK TO LINE FIREBOX INTERIOR D. STANDARD CAST IRON POKER -STYLE DAMPER (OPTIONAL TOP MOW DAMPER). W. INSTALLAT06 A. REFERENCE MANUFACTURERS INSTALLATION INSTRUCTIONS FOR STANDARD CONFIGURATIONS,,*EIGHTS, SIZES AND INSTALLATION DETAILS. B. SUITABLE MASONRY FOJNDA71ON AND NONCOMBUSTIBLE HEARTH EXTENSION MAST BE PROVIDED. G. UNIT TO BE A55EMBLED ON 51TE PER MANUFACTURER'S ILLUSTRATED INSTRUCTIONS. I. PREMIXED 15OKERN LIP MORTAR 15 U5ED AT ALL .JOINTS BET161EEN COMPONENTS. 2. FIREBOX TO BE LINED WITH MINIMUM 1116' RATED FIRE BRICK. D. STANDARD FIREPLACE AND CHIMNEY UNITS L15TED FOR 'ZERO CLEARANCE" TO UUNINSULATEDU W00D FRAMING MEMBERS. V. GERTIf�G/►TIOM4 A. AARNOCK HERSEY/1NTERTEK TE5TING SERVICES REPORT NO. 652A12500. B. MEETS OR EXCEEDS U.L. 105HT; U.L. 121-1111; U.L. I"M; U.L.G. 5610; ANSI 2.11. M. CODE 000 PI.IANGE: A. LOB.0. NO. 501-1 / SBGU NO. gb2b / MEA N.Y.G. 241-40-E. IWKM FIFMAGE AND Wit -W 9IW..1PI6ATI0Nm RIS INSULATED STEEL CHIMNEY (U L. REPORT # 105HT) STAINLESS STEEL ANCHOR PLATE BY CHIMNEY MANUFACTURER 3/8" ANCHOR BOLT5 REFRACTORY CEMENT - MASONRY FIREPLACE OWKERN) 4. f: INSTALL ALL CHIMNEY COMPONENTS PER MANUFACTURE'S INSTRUCTIONS IRP. CHIMNEY TRAM noN VENT GAP PER MANUF, SPEOS 6.1. METAL OAP 6.1. FLA5HIN6 AND COUNTER FLASHING AND SEALANT SLOPE TO 2X10 TRIM W/ DRAIN 5TUCCO OVER "SUPER .NMBO-TEX" CO MIN. PAPER GOVT. EXTERIOR STUCCO 2X EXT STUDS FLUE PROVIDE MANUFACTURE APPROVED SPARK ARRESTOR. SCALE: 1" = 1'_0" CHIMNEYS ATTACHED TO ANY APPLIANCE OR FIREPLACE THAT BURIALS SOLID FUEL SHALL BE EQUIPPED WITH AN APPROVED SPARK ARRESTER. THE NET FREE AREA OF THE SPARK ARRESTER SHALL NOT BE LESS THAN FOUR TIMES THE NET FREE AREA OF THE OUTLET OF THE CHIMNEY. THE SPARK ARRESTER SCREEN SHALL HAVE HEAT AND CORROSION RE515TANCE EQUIVALENT TO 0.109" (NO. 12 B.W. 6A6E) WIRE, 0.042" No. 14 B.W. 6A6E) 6ALVANIZED WIRE OR 0.022" (NO. 24 B.W. 6A&E) STAINLESS STEEL. OPENIN65 SHALL NOT PERMIT THE PASSA6E OF SPHERES HAVIN6 A DIAMETER LAR6ER THAN 1/2" AND SHALL NOT BLOCK THE PASSAGE OF 5PHERE5 HAVIN6 A DIAMETER OF LESS THAN 5/6". CAN LltlmjT EEI:, •' q) SWELVING -INTERIOR ELtiATIOR 11 1 G.I. C[41CAP W/ I.C.B.O. APPROVED SPARK AWESTOR. PROVIDED BY FIREPLACE MANLIFACTURE32. 2X4 W/ STUCCO O/ Q ev RIGHT L VATI 0 SCALE: 1/4" = V-0" G.I. CHIK44EY CAP W1 I.C.B.O. APPROVED SPARK ARRESTOR. ENVY REAR ELEVATION 12._0 SCALE: 1 /4" = 1'— A;�QD SURFACE GUEST SUITE P12OVIDED BY F91253LACE MANUFACTURER. 2X4 W/ STUCCO 0/ Q t LEFT ELEVATION SCALE: 1/4" = 1'-0" G.I. CHINIsEY CAP W/ I.C.B.O. APPROVED SPARK ARRESTOR. =_- PROVIDED BY FIREPLACE AC . 2X4 W/ STUCCO 0/ -- - - 4 --------------- N FRONT ELEVATION SCALE: 1/4" = 1'-0" Fggtj���� HALL_ 10'-0" CL' G ffvffr.l 9'-0' CL' G R1 -, N�t I. --= I I 4 1 OW A I I XISTING CAS11A VERIFY LOCATION OF SMOKE DETECTOR P_ FRONT SIM -9014 5 I �� QIEST NON-GOM5Z 5722 nBLE ! HEARV - REAVILY 10°-0" G, DISTINWISHASLE FROM j FLOOR NDING / ADJACENT .7. 1 ril II �}g i 6X8 N 6)*BOTT T 50ii®� AT b' -O' I 5LOGCINS 8'-O" STRONG -TIE STRAP I FRAMING 850TTOM AT c0 tpW LEACH �ll�.D B1 LOOKIN6 - + TF}'1 \ 1� L. ,A LW I ! 25'-4' 5'MM I 7 I — — — — — — — — — — — 6"X 24" ISOKERN FIREPLACE. PROVIDE LARGE CROWN CAP AND SPARK ARRESTOR / RAIN CAP. I.C.B.O. NO. 5017. 6X8 COMBUSTIBLE MATERIALS SHALL NOT BE PLACED WITHIN 6" (152mm) OF TTOM AT THE FIREPLACE OPENING. NO SUCH MATERIAL WITHIN 12" (305mm) OF THE 2'-4' 5'-4' 2'-4' g""0" VV FIREPLACE OPENING SHALL PROJECT MORE THEN 1/8" (3mm) FOR EACH 1' N (25mm) CLEARANCE FROM SUCH OPENING. CBC SECTION 3102.7.8 101-0" COMBUSTIBLE MATERIALS SHALL NOT BE PLACED WITHIN 6" (152mm) OF -- THE FIREPLACE OPENING. NO SUCH MATERIAL WITHIN 12" (305mm) OF THE FIREPLACE OPENING SHALL PROJECT MORE THEN 1/8" (3mm) FOR EACH 1' (25mm) CLEARANCE FROM SUCH OPENING. CBC SECTION 3102.7.8 MANUFACTURERS SPECIFICATIONS). FL1313R PLAN / SITE PLAN DEMO SCALE: 1/411 = II_011 u 4 NEA CHIMNEY SCALE: 1/811 = V-011 A A SEP 0 4 2907 BUILDING CODES.' 2001 GALf1=0RN1A BU1LL71N6 CODE (G130) 2001 CALIFORNIA MECHANICAL GODS (CMG) 2001 CALIFORNIA PLUME3IN6 GODS (CPG) 2004 CALIFORNIA ELECTRICAL GODS: (CEG) 2001 GaL1i=ORNIA FIRE: CODE (CFC) `zo& 20035 CALIFORNIA ENERGY CODE (T24 ) L 00) WIM Jim • R PLOT: 8/24/2007 1221 PM F91 E, Fireplace 1