Loading...
BMCH2015-0365a 7w VOICE (760) 777-7125 8-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 /1 FAX (760) 777-7011 COMMUNITY DEVELOPMEN DE ARTMENT INSPECTIONS (760) 777-7153 BUILDING R"M�T S,� o O Date: 9/24/2015 Application Number: BMCH2O15-0365 P G 42 ff 11 w er: Property Address: 79717 LIGA CO Cl Ol�i EN LHOMMEDIEU APN: 776180013 V NNN!)y�FVoFrq �T 17 LIGA Application Description: LHOMMEDIEU RESIDENCE / 3 HVAC CHANGE OUT OPtif �A QUINTA, CA 92253 Property Zoning: f?qR fNT Application Valuation: $50,072.00 Applicant: Contractor: IE INC. HARRISON ENTERPRISES INC DBA GENERAL AIR 32115 LA BAYA 31170 RESERVE DRIVE WESTLAKE VILLAGE, CA 91362 THOUSAND PALMS, CA 92276 (760)601-3500 Llc. No.: 686310 LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, and my License is in full force and effect. License Class:: C20 C36 License No.: 686310 Contractor: OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: ( ) I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not. apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). ( 11, as owner of the property, am exclusively contracting with licensed contractors to construct the project. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). (_) I am exempt under Sec. . B.&P.C. for this reason Date: Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Lender's WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier:- Policy Number: _ I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, if I should become subject to the workers' compensation provisions of Section 3700 of the Labor Code, I shall forthwith comply With thos provisions. WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT: Application is hereby made to the Building Official for a permit subject to the conditions and restrictions set forth on this application. 1. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application , the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents, and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter upon the above- rrenvo ned pro erty for inspection purposes. Date7� ` Signature -'(Applicant of Agent): FINANCIAL INFORMATION PESCRIPTION ACCOUNT QTY AMOUNT PAID' PAID DATE BSAS SB1473 FEE 101-0000-20306 0 $3.00 $0.00 PAID BY .,METHOD RECEIPT # CHECK # CLTD BY Total Paid for BUILDING STANDARDS ADMINISTRATION BSA: $3.00 $0.00 DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE HVAC CHANGEOUT - SPLIT -SYSTEM 101-0000-42402 0 $217.56 $0.00 PAID BY METHOD RECEIPT # CHECK # CLTD BY DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE HVAC CHANGEOUT - SPLIT -SYSTEM PC 101-0000-42600 0 $108.78 $0.00 PAID BY METHOD RECEIPT # CHECK # CLTD BY Total Paid for CHANGEOUT: $326.34 $0.00 DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE PERMIT ISSUANCE 101-0000-42404 0 $91.85 $0.00 PAID BY METHOD RECEIPT # CHECK # CLTD BY Total Paid for PERMIT ISSUANCE: $91.85 $0.00 TOTALS:• 00 Description: LHOMMEDIEU RESIDENCE / 3 HVAC CHANGE OUT Type: MECHANICAL Subtype: Status: UNDER REVIEW Applied: 9/24/2015 MFA Approved: 9/24/2015 MFA Parcel No: 776180013 Site Address: 79717 LIGA LA QUINTA,CA 92253 Subdivision: TR 24890-6 Block: Lot: 37 Issued: Lot Sq Ft: 0 Building Sq Ft: 0 Zoning: Finaled: Valuation: $50,072.00 Occupancy Type: Construction Type: Expired: No. Buildings: 0 No. Stories: 0 No. Unites: 0 APPLICANT Details: (3) HVAC CHANGE OUT - 5 TON 20 SEER, 4 TON 21 SEER, 2 TON 23 SEER SPLIT SYSTEM [2008 ENERGY] CARBON MONOXIDE ALARM(S) TO BE INSTALLED PRIOR TO FINAL INSPECTION. 2013 CALIFORNIA BUILDING CODES. CHRONOLOGY CONDITIONS NAME TYPE NAME ADDRESSI CONTACTS CITY STATE ZIP PHONE FAX EMAIL APPLICANT IE INC. 32115 LA BAYA WESTLAKE VILLAGE CA 91362 (760)258-6700 CONTRACTOR HARRISON ENTERPRISES INC DBA GENERAL AIR 31170 RESERVE DRIVE THOUSAND PALMS CA 92276 (760)258-6700 OWNER STEVEN LHOMMEDIEU 79717 LIGA LA QUINTA CA 92253 1 (760)258-6700 Printed: Thursday, September 24, 2015 1:11:16 PM 1 of 2 CRsysrc,ins r ...., . . Permit Details - PERMIT NUMBER City of La Qpinta , .., BMCH26115!0365 PARENT PROJECTS Printed: Thursday, September 24, 2015 1:11:16 PM 2 of 2 rWSYS7EMS CLTL� DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE RECEIPT # CHECK # METHOD PAID BY , BY BSAS SB1473 FEE 101-0000-20306 0 $3.00 $0.00 Total Paid for BUILDING STANDARDS ADMINISTRATION $3.00 $0.00 BSA: HVAC CHANGEOUT - 101-0000-42402 0 $217.56 $0.00 SPLIT -SYSTEM HVAC CHANGEOUT - 101-0000-42600 0' $108.78 $0.00 SPLIT -SYSTEM PC Total Paid for CHANGEOUT: $326.34 $0.00 PERMIT ISSUANCE 101-0000-42404 1 0 $91.85 $0.00 Total Paid for PERMIT ISSUANCE: $91.85 $0.00 TOTALS: $421.19 $0.00 PARENT PROJECTS Printed: Thursday, September 24, 2015 1:11:16 PM 2 of 2 rWSYS7EMS TRA4 VG [or atoa for tsson issae N SobntkW Rwd . Ree,d moo City•of La QWho Pka Seb Plan Geek Balance. a Safety Dwon Permit # Strachral CalmRevt P.O Box 1504,'78-49S Calle Tamptto Meeks"for vmk ready LA -W4 CA 92253..-(760) 777-7012 [ttns Cala. Building Permit Applicadon and Tracking Sheet Caped Comet P Projea Addm S.M.i. Q. Owner's Name:. - • Grading A. P. Nwnber A:Legrn Devdoper impact Fee °lDcsc"ptQ1`. City, ST, Zip. LA QUINTA, CA A.U.P. Contractor: GENERAL A/C & HEATING Tdephoae: ' Address: 31170 RESERVE DRIVE Pnojea De-cipaan: City, ST, Zip: THOUSAND PALMS, CA 92276 -0 Sabeoaaetor i A Telq*Ow-760-343-7488 J R ro Caped Contact P State [.ia #: 686310. City Lie.,�6n �� SLP.Q. I ' Grant Deed Arch., Engr, Dasip w. (ln a Plans Pfd tap Addr= t" .� City. ST. 4: Plans resubmitted ' . Tedephoae: . Co **Won Type: Oecupm' CY: State l.ie. g: ' P'oJca type (CW0 one): New Add'n Alter Repair Demo NTOofConwPerson: PATRICK ...___ • Sq. Ft.: � IF Stories: p Unita Tekpboae f of Coruact person: 760-343-7488 ' C O� . Estimated• Value of project: : J0 APPLICANT: DO NOT WRITE 8110W THIS UNE TRA4 VG [or atoa for tsson issae N SobntkW Rwd . Ree,d moo Pian Clock Deposit Pka Seb Plan Geek Balance. Pisa Cke& gbffi Coratraeden Strachral CalmRevt Meeks"for vmk ready Electrical [ttns Cala. Plantbiag Caped Comet P S.M.i. Tine 21 Cala. Grading Pkm paid up Devdoper impact Fee Flood plata plan A.U.P. Plans raubmitted ' Gi'adiag plan 1' Review, ready Sabeoaaetor i A Total Permit Feet Caped Contact P Grant Deed Plans Pfd tap H.O.A. Approval Plans resubmitted IN HOUSE:- ,,e Renew. ready Planning Approval Can Contact P Pub. Wks. Appr - Date of perait S&od Fee TRA4 VG [or atoa for tsson issae PEBhRT FEn ued L Anont moo Pian Clock Deposit Plan Geek Balance. Coratraeden Meeks"for correctiouftue Electrical rsoa Plantbiag S.M.i. Grading eormdonLqune Devdoper impact Fee A.U.P. ' Total Permit Feet CERTIFICATE OF COMPLIANCE Alterations to Space Conditioning Systems (formerly CF -1R -ALT HVAC) Project Name: STEVE LHOMMEDIEU I Date Prepared: CF111-ALT-014 (Page 1 of 9 ) 2015-09-24 A. General Information MR -ALT -02 is applicable to multiple space conditioning systems contained within a single dwelling unit. When multiple dwelling units must be documented, use one CF1R-ALT-02 document for each dwelling unit. 01 Project Name STEVE LHOMMEDIEU 02 Date Prepared 2015-09-24 03 Project Location 79717 LIGA 04 Building Type Single family 05 CA City La Quinta 06 Dwelling Unit Name STEVE LHOMMEDIEU 07 Zip Code 92253 013 Dwelling Unit Conditioned 4025 Installing palling, Installing Floor Area (ft2) Location or Area by this SC Iducted containing system Number of space conditioning entirely en w 09_ Climate Zone 15 10 (SC) systems in this dwelling 3 component? components? _ duct system? unit. Alteration Type B. Space Conditioning (SC) System'lnformation-' 01 02 r 03 ` 04 05 is 1E 006 4 IAL 07 -, i 08 1 09 _ 10 the SC— ` 'Installing a` SC System SC System CFA served "%,,system a-« refrigerant t *Installing new SC Installing palling, Installing Identification or Location or Area by this SC Iducted containing system more than 40 entirely en w entirely new Name Served System (ft2) system? component? components? feet of ducts? duct system? SC system? Alteration Type System 1 Location 1 1342 Yes Yes Yes No No No Altered space conditioning system System 2 Location 2 1342 Yes Yes Yes No No No Altered space conditioning system System 3 Location 3 1342 Yes Yes Yes No No No Altered space conditioning system C. Extension of Existing Duct System, Greater Than 40 Feet (Section 150.2(b)iDiib) This section does not apply to this project. Registration Number: 215-A6336501A-000000000-0000 Registration Date/Time: 2015-09-24 09:12:10 HERS Provider: CaICERTS CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version: 2013-1.006 Report Generated: 2015-09-24 09:11:45 Schema Version: 0.555SDD CERTIFICATE OF COMPLIANCE CF1R-ALT-02-E Alterations to Space Conditioning Systems (formerly CF -1R -ALT -HVAC) (Page 2 of 3 ) D. Altered Space Conditioning System (Sections 150.2(b)lE and F) 01 02 03 04 05 06 07 08 09 10 11 12 Heating Cooling System Heating Altered Heating Minimum Altered Cooling Minimum Required New or Identification System Heating Efficiency Efficiency Cooling Cooling Efficiency Efficiency Thermostat Replaced New Duct or Name Type Components Type Value System Type Components Type Value Type Duct Length R -Value Central gas All new Central split All new This field or This field or System 1 furnace heating AFUE 0.8 AC cooling SEER 20 Setback section is not section is not components components applicable applicable Central gas All new Central split All new This field or This field or System 2 furnace heating AFUE 0.8 AC cooling SEER 21 Setback section is not section is not components components applicable applicable Central gas All new Central split All new This field or This field or System 3 furnace heating AFUE 0.8 AC cooling SEER 23 Setback section is not[section is not components - components applicable applicable Reauired Documentation:CF2R_,- MCHation -Space Conditioning Systems Ducts and Fans y P4O insulation for R6. "CF2R-MCH-20-H -Duct requirement new plenums: -Duct when heating installed inducted thanft duct length is & CF3R-MCH-20 H —Duct Leakage testing requirecJ or cooling components are systems, or when more of Leakage rate compliance: 515%, or 510% leakage to outside or seal'all accessible]eaks. 4 ° replaced. CF2R-MCH-25-H & CF3R-MCH-25-H Refrigerant Charge Verification required whenrefrigerant containing components are installed or altered (applicable in CZ 2, 8-15). CF2RCF3R-MCH-23 & CF3R-MCH-23 Air Flow 2 300 CFM/ton required when MCH-2S.is equlred. R S � }� D E R. Exceptions: ;i -Duct systems registered with HERS provider as previously sealed are exempt from MCH -20 Duct Leakage Testing requirements. -Heating-only systems and Air Handler/Furnace changes do not require verification of Air Flow MCH -23, or Refrigerant Charge MECH-25. -Existing duct systems constructed, insulated or sealed with asbestos are exempt from MCH -20 Duct Leakage Testing requirements. E. Entirely New or Complete Replacement Duct System, with or without Equipment Changeout (Sections 150.2(b)1Diia and 150.2(b)1E, F) This section does not apply to this project. F. Entirely New or Complete Replacement Space Conditioning System (Section 150.2(b)1C) This section does not apply to this project. Registration Number: 215-A6336503A-000000000-0000 Registration Date/Time: 2015-09-24 09:12:10 HERS Provider: CaICERTS CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version: 2013-1.006 Report Generated: 2015-09-24 09:11:45 Schema Version: 0.555SDD CERTIFICATE OF COMPLIANCE CF111-ALT-024 Alterations to Space Conditioning Systems (formerly CF -1R -ALT -HVAC) (Page 3 of 3 ) Documentation Author's Declaration Statement 1. 1 certify that this Certificate of Compliance documentation is accurate and complete. Documentation Author Name: Documentation Author Signature: n Jacoby, Ian c9an �aco Jt. Company: Signature Date: i PERMIT E RATERS 2015-09-24 09:11:46 Address: CEA/ HERS Certification Identification (if applicable): 31225 La Baya Drive #213 City/State/Zip: Phone: West Lake Village CA 91362 818-735-7876 Responsible Person's Declaration statement!, I certify the following under penalty of perjury, under the laws of the State of California: 1. The information provided on this Certificate of Compliance is true and correct. 2. 1 am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design or system design identified on this Certificate of Compliance (responsible designer). 3. That the energy features and performance specifications, mate ria ls,'compo nnents, and manufactured devices for the building design or system design identified on this Certificate of Compliance conform to the requirements of Title 24, Part land Part 6 of the California Code of�Regulation 4. The building design features or system design features identified on this Certificate of Compliance are consistentwith.the information provided on other,,applicable compliance documents, worksheets, calculations, plans and specifications submitter! to the enforcement agency for proval with this building permit application. "'+� I I 11 5. I will ensure that a registered copy of this Certificate of,Compliance shall be made available with the building permrt(s) issued for the building, and made available to the,enforcement agency for all applicable inspections. I understand that a registered copy of this Certificate of Compliance is,required to be,included with the,documentationkthe builder provides to the building owner at occupancy. �.. Responsible Designer Name: » —J Responsible Designer Signature:` Shanley, Barbara �� Company: Date Signed: HARRISON ENTERPRISES INC dba GENERAL AIR CONDITIONING 2015-09-24 09:12:10 Address: License: 31-170 RESERVE DRIVE STE A 686310 City/State/Zip: Phone: THOUSAND PALMS CA 92276 760-343-7488 Digitally signed by Ca10ERTS. This digital signature is provided in order to secure the content of this registered document, and in noway implies Registration Provider responsibility for the accuracy of the information. Registration Number: 215-A6336501A-000000000-0000 Registration Date/Time: 2015-09-24 09:12:10 HERS Provider: CaICERTS CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version: 2013-1.006 Report Generated: 2015-09-24 09:11:45 Schema Version: 0.555SDD