Loading...
0107-218 (SFD)'LICENSED CONTRACTOR DECLARATION-" rhereby affirm under penalty of pe 'ury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Divisi6n 3 of the Business and Professionals Code, and my License is in full force ind effect. i License # Lic. Class Exp. Date t571 203 B 0, [Date 7"ISignature of 0 , WNE R- BUILDER DECI AaATION I hereby affirm under penalty of perjury that I am exempt from the Contractor's License Law for the following reason: ( ) 1, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec. 7044, Business & Professionals Codc). ( ) 1, as owner of the property, am exclusively contracting with licensed cont ractors to construct the project (Sec. 7044, Business &-Professionals Code). - - % ( ) I am exempt under Section _, B&P.C. for this reason Date Signature of Owner WORKER'S COMPENSATION DECLARATION I hereby affiim under penalty of perjury one of the following declarations: ( ) I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section' 3700 of the Labor Code, for the performance of the work for which this permit is issued. I have and will maintaln workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit. is issued. My workers' compensation insurance carrier & policy no. are: Carrier Policy No. (This section need not be completed if the permit valuation is for $100.00 or less). ( ) I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that if I should become subject to the workers' compensation provisions of Section 3700 of the Labor Code, I sli'all forthwith comply with thoso�,`prdVisions. Date:,�Z/_-, Applicant-, Warning: Firffil—re-t7d`secure, Workers' Co I r' n6ens-ation coverage is unlawful and shall subjectan employer to criminal penaltiesand civil fines upto$100,000, 'in addition to the cost of compensation, damages as provided for in Section 3706 of the Labor Code, interest and attorney's fees. IMPORTANT Application is hereby made to the Director of Building and Safet for a permit subject to the conditions and restrictions set forth on hi application. 1. Each person upon whose behalf this application is made & each person a i a whose request and for whose benefit work is performed under or pursuant t any permit issued as a result of this applicaton agrees to, & shall, indemni m i M, p )JO & hold harmless the City of La Quinta, its officers, agents and employees 2. Any permit issued as a result of this application becomes null and void i work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is correct. I agree to comply with all City, an d ' -State laws relating to the building construction, and hereby authorize representati�es of this City to enter upon the above-mentioned property for -in, ection purposes. '�p s ignature (Owner/Agent)-"�',t"*i� ��Date--- PERMIT# % PERMIT. /-BUILDING- ._ . , �.,6. VALUATION LOT TRACT DATE 0101 US' SA14.�Q .7 30056, JOB SITE . '�APN ADDRESS rovu 7.7(3, -019 P.WNER CONTRACTOR DESIGNER / EN61NEER 111R_WM,014 C1XB AIMUMMM14 tam'Row Pi—nap cow'OT"Anav 78-iM 01-DAMAM 51 44835DUP CANYON M LA QTW'A CA 92253 PALM DFqMr CIA -92261, (?60)346-nZS MIX' 03031,. USE OF PERMIT �'ANMXY IFAWELY DWFLUNG 8F1`)(,29)41FR,M IT DOFZ -NOT 1NCJUVF D.WCK WAJAP00113PA OR .&MIROAON rJRIVTNMAY'CO3 Ml"UAHOE WITH AU, FEDRRAL &STATF. LAW% NCIAJUrNG THE ACT OF 19733(16 U.S.C. cua-lom CONSTRUCT104 M37.00 OF 13"AM CARPORT wio.w SF HMMATED COST 01r'CQN2;rHUCv110-N 283014�X FEWAM YME suhWARY CONSTRUCTION FLM 101 r�000-41 8-000 $1,28311" KAN CHECK PZZ 101-WO,439-318 HXCHANICAL FEZ 101 -000 -421 -ON X10C.TPUCAL MKIR 101-000-420-000 1.11LUMBINO n -E 101-0M419-000 STRONO MOTION IFFS fl-, 101-000-24,11-000 $29.38 CIRADNO FRY,' 101.,000-42.'d-000.- MAI DZVEL-OPER IMPACT YZE ART 110 PUBLIC' PLAMIW RESIr 701-000455-000 101-000-439-118 -11334.0 fix R C7 J U L 2 0 $4,285.81 ;_,F"Ss PRF!".:PAM no CITY OF LA 0 INTA T( PEJOW 1"EXES DUE A OW FINANCE DEPT RECEIPT DATE ONALEY.2 IN SP ECTOR r INSPECTION RECORD OPERATION T—DATE INSPECTOR OPERATION --7-1 DATE —FINSPECTOR BUILDING APPROVALS MECHANICAL APPROVALS Set Backs Forms & Footings Underground Ducts Ducts Stab Grade Return Air Steel Combustion Air Roof Deck Exhaust Fans O.K. to Wrap F.A.U. Framing Compressor Insulation �z_ Vents Fireplace P.L. Grills Fireplace T.O. Fans & Controls Party Wall Insulation Condensate Lines Party Wall Firewall Exterior Lath Drywall - Int. Lath Final Final -/7' I POOLS -SPAS BLOCKWAI AP ROVALS Steel Set Backs Electric Bond Footings Main Drain Bond Beam Approval to Cover Equipment Location Underground Electric Underground Plbg. Test Final Gas Piping PLUMBING &F�PROVA S Gas Test Waste Lines' Electric Final Heater Final Water Piping Plumbing Final Plumbing Top Out Equipment Enclosure Shower Pans O.K for Finish Plaster Sewer Lateral 'A Pool Cover Sewer Connection Encapsulation Gas Piping Gas Test Appliances Final COMMENTS: Final Utility Notice (Gas) ELECTRICAL APPROVALS Temp. Power Pole Underground Conduit Rough Wining Low Voltage Wiring Fixtures Main Service Sub Panels Exterior Receptacles G.F.I. Smoke Detectors Temp. Use of Power Of Final Utility Notice (Perm) Notice: Document Cannot Be Duplicated Date 7/19/01 Desert Sands Unified.Scho-01 District 47-950 ii Une Palms'Road La Quinta,;.-CA 92253 760-77.1-8515 CERTIFICATE OF COMPLIANCE No. 22275 Jurisdiction Owner NamieCoyote Comer LLC No. 78-186 Street Pinnacle- Point city La Quinta Zip 92253 A.PN# 770-370-019 La Quinta Permit # 1,og # Study Area Tract # Lot # SquareFodtage '3437 Type of Develo.0ment Single Family R6sidence No. of Units I Comments At the present time, the Desert Sands Unified .&hool` 'Dikridt does not collect fees, on garages/carports, covered patios/walkways, residential additions under 500 square.feet,- detached acce§sory kructiir�s or replacement mobilehomes. It has been deterniined the above-named owner is exempt from. 04ying.school-f6es at this time due to the following reason: EXEMPTION NOT APPLICABLE This certifies that school facility fees imposed pursuant to Government Code 53680 in the amount of 2.05 X 3,437 or $'7,045.85 Ahe prope4y lisf above and that building permits and/or Certificates of Occupancy for this square fboitiaig-emi this proposed project may 'now be -issued Fees Paid By cc/PD, National,.Blank/Autumn Sims Tele phonC..771-5,02l Nam�e'on the check.' By Dr.- Doris Wilson Superintendent. Fee collected /exempted by Juanita Green Payq�nt R6ceiVed $7,045.85 'Check No. 082.3119 Signature 41 NOTICE: Pursuant ot Aqq4nbIj 611`3691�(C 0 - HAP fi,19'�STATS_1998) this will serve to nofifyyrou thit the g, day approval period in which you may protest the fees or other payment identified above will begin to run fro the date on Which the bui!�ing or i�stallation permit for this priijkt issssuiid or onwhich.theY iii paid to the DistriEt(s) or to another public entity authorized to collect them.on the Districtfs)(s) behalf, whichever is girlier. Collector: Attach a copy of.cotinty or city plan check applicati'onfoi-m4o district copy for. all waivers. Embossed Original- Building Deipt./Appliedrit Copy - Applican*ecbipt Copy - Accounting REGISTERED INSPECTOR'S WEEKLY REPORT JONTANDY 37630 Medjool Ave. Pak. Desert, CA 92211 Office'.(760) 772-7192 'F,ax (760) 772-7193 P'a ' ger (760) 776-3338 TYPE OF INSPECTION PERFOR I MED b REINFORCED CONCRETE 0 STRUCT. STEEL ASSEMBLY 0 POST TENSIONED CONCRETE O�ASPHALT, 0 REINFORCED MASONRY 0 FIRE PROOFING 0 OTHER JOB LtC-jT6;N QU : _ REPORT SEOLIENCE NO. TYP FEAURE 7 PERMIT NO Of 69 cal Dtb DAY I OF WEEK MATER14L DESCRIPTION ARCHITECT. iUadCTO*R r HRS.CHARGED ENG.INEER ASSISTANTS HRS.CHARGED INSPECTION .DATE GENERAL CONTRAC,TOR SUB CONTRACTOR OASORU6 elR';P-� toq,-�. S' vvv COPY SENT TO CLIENT 0 CO�Tlhlrf�N NEXT !AGE. 0 PAGE of CERTIFICATION OF COMPLIA NCE I HEREBY CERTIFY THAT I HAVE INSPECTED TO THE BEST OF MY' '64GNATURE OF REGISTER CTOR KNOWLEDGE ALL OF THE A80VE REPORTEDWORK UNLESS OTHERWISE 77 NOTED. I HAVE FOUND THIS WORK TO COMPLY WITH THE APPROVED T& o 1� -(2�- PLANS, SPECIFICATIONS. AND APPLICABLE. SECTIONS OF THE -'IDATE CFF REPORT REGISTER NUMBFR GOVERNING BUILDING LAWS. Certificate of 07CCU a - p ncy City of La. Quint -a Ar - ffff� dSaf ety-D epartment suitaing an ThisIr Cerkicate issued pursuant to the ents of Section 109.of the Uniform,Buil ding Code, requirem certifying,, that, �at the time of issuance, this structure was,in compliance with the vaho' ord4qanc'es us of the City regulating building constructio h or use. Fot the following. - a BUILDING ADDRESS' 78-186 PINNACLE'POINT Use Cla,�s'ificatibh- SINGLE FAMILY'DWELLING' Bldg. Permit No.: 0-107-'218 Occupancy Group: R-3 Type of Construction: VN Land Use Zone: RL . Owner of Building: TAADITION-CLUB ASS.00IATES.. Building Official Address: 78-5WOLD AVENUE 52 City: LA QUINTA, CA 92253 By: RICHARD kIRKLAND Date: 05-20-02 POST IN A CONSPICUOUS PLACE M TITLE 24 REPORT Title 24 Report for: Tradition VUlage Plan 2B Tradition Golf Club La Quinta, CA 92253 Project Designer: CITY OF LA QUINTA BUILDING & SAFETY DEPT APPROVED FOR CONSTRUCTION DAFE !L�3 - 01 BY offie-6 51E -f McLarand Vasquez Emsiek & Partners, Inc. 1900 Main Street 8th Floor Irvine, CA 92614 14 if W -Too— �1� 9;5 (949) 809-3300 f4-12- u,/%i zat'3pr� C'00140L- jkp–�At� mp'-='s Report Prepared By: Tim Scott BREEZE AIR CONDITIONING 75-145 ST. CHARLES PLACE PALM DESERT, CA 92211 (760) 346-0855 Job Number: Date: 7/2/01 0 1 xv a jjer'5' The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is 'authorized by the California Energy Commission for use with both the Residential and Nonresidential 2001 Building Energy Efficiency Standards. This program developed by Gabel Dodd/EnergySoft, LLC (415) 883-5900. I EnergyPro 3.0 By EnergySoft Job Number: User Number: 3665 1 0 9 Certificate of Compliance: Residential (Part 1 of 2) CF -1 R Tradition Village Plan 2B 7/2/01 P-roi-ecrTiff-e- Date Tradition Golf lub La Quinta vrojeCt A00reSS BREEZE AIR CONDITIONING (760) 346-0855 Documentation Author i eiepnone Computer Performance 15 Building Permit# Plan Check Date Held Check Date Compliance Method (Package or Computer) Climate Zone Enforceme�_tA_gency Use Only GENERAL INFORMATION Total Conditioned Floor Area: 3,437 fe Average Ceiling Height: 10.7 ft Total Conditioned Slab Area: 3,437 fe Building Type: Wood (check one or more) Exterior Roof [XI Single Family Detached F-] Addition F� Single Family Attached n Existing Building F1 Multi -Family F-1 Existing Plus Addition Front Orientation: All Four OrientationS Floor Construction Type: FX_] Slab Floor Number of Dwelling Units: 1.00 Number of Stories: 1 F-] Raised Floor BUILDING SHELL INSULATION Component Type Frame Type Assembly U -Value Location/Comments (attic, garage, typical, etc.) R-38 Roof (R.38.2xl4.16) Wood 0.028 Exterior Roof R-21 Wall (W.21.2x6.16) Wood 0.059 Exterior Wall Slab On Grade n/a 0.756 Exposed Slab w/R-0.0 Perimeter Insulation Slab On Grade n/a 0.756 Covered Slab w/R-0.0 Perimeter Insulation Solid Wood Door None 0.387 Exterior Door FENESTRATION Shading Devices Type Orientation Area Fenestration Exterior Overhang Side Fins (SF) U -Factor SHGC Shading Yes / No Yes / No Rear 34.0 0.48 0.49 Bug Screen Rear 69.4 0.46 0.49 Bug Screen Right 81.0 0.46 0.49 Bug Screen Right 32.0 0.48 0.49 Bug Screen Front 34.0 0.48 0.49 Bug Screen 1:1 1XI El X Front 32.0 0.46 0.49 Bug Screen 1XI 1:1 El X Front 32.0 0.48 0.49 Bug Screen ff] 1:1 1:1 X Left 123.0 0.46 0.49 Bug Screen 1:1 N El X Left 130.0 0.48 0.49 Bug Screen F1 El 1:1 1XI Rear 34.0 0.48 0.49 Bug Screen N 11 El X E] 1:1 El R El El El El Run Initiation Time: 07102/01 07:32:11 Run Code: 994084331 EnergyPro 3.0 By EnergySoft User Number: 3665. Job Number: Page:3 of 46 Pertificate of Compliance: Residential (Part 2 of 2) CF -1 R Tradition Village Plan 2B 7/2101 T'r–aiieci e— Date HVAC SYSTEMS Note: Input Hydronic or Combined Hydronic data under Water Heating Systems, except Design Heating Load. Distribution Type (air conditioner, Efficiency Location Duct Heating Equipment Minimum Type and Duct or R -Value Type Comments Type (furnace, heat Efficiency Location Piping Thermostat Location pump, etc.) (AFUE/HSPF) (ducts, attic, etc.) R -Value Type Comments Central Furnace -80% AFUE Ducts in Attic 4.2 Setback HVAC -11 Central Furnace -80% AFUE Ducts in Attic 4.2 Setback HVAC -2 Central Furnace 80% AFUE Ducts in Attic 4.2 Setback HVAC -3 Cooling Equipment Minimum Duct Type (air conditioner, Efficiency Location Duct Thermostat Location heat pump, evap. cooling) (SEER) (attic, etc.) R -Value Type Comments Split Air Conditioner 14.0 SEER Ducts in Attic 4.2 Setback HVAC -11 Split Air Conditioner 15.8 SEER Ducts in Attic 4.2 Setback HVAC -2 Split Air Conditioner 12.1 SEER Ducts in Attic 4.2 Setback HVAC -3 WATER HEATING SYSTEMS Rated Tank Energy Fact External Water Heater Water Heater Distribution # in Input Cap. or Recovery Standby Tanklnsul. System Name Type Type Syst. Btu/hr (gal) Efficiency Loss R -Value AMERICAN G52 -75T75 Small Gas Recirc/Time+Temp 1 74,500 75 0.51 n/a 12 isI —factor. For small gas storage (rated inputs of less than or equal to 75,000 Btu/hr), electric resistance and heat pump water heaters, list energy For large gas storage water heaters (rated input of greater than 75,000 Btu/hr), list Rated Input, Recovery Efficiency and Standby Loss. For instantaneous gas water heaters, list Rated Input and Recovery Efficiency. REMARKS This certificate of compliance lists the building features and performance specifications needed to comply with Title 24, Parts 1 and 6 of the California Code of Regulations, and the administrative regulations to implement them. This certificate has been signed by the individual with overall design responsibility. When this certificate of compliance is submitted for a single building plan to be built in multiple orientations, any shading feature that is varied is indicated in the Special Features/Remarks section. Designer or Owner (per Business & Professions Code) Documentation Author Name: Name: Title/Firm: McLarand Vasquez Emsiek & Partners, Inc. Title/Firm: Address: 1900 Main Street 8th Floor Address: Irvine, CA 92614 Telephone: (949) 809-3300 Lic. #: (signature) (date) Enforcement Agency Name: Title/Firm: Address: Telephone: Tim Scott BREEZE AIR CONDITIONING 75-145 ST. CHARLES PLACE PALM DESERT. CA 92211 Telephone: (760) 346-0855 (s.lg e) jdatb) (signature/stamp) (date) I Run Initiation Time: 07/02/01 07:32:11 Run Code: 994084331 I EnergyPro 3.0 By EnergySoft User Number: 3665 Job Number: PageA of 46 9 Certificate of Compliance: Residential (Addendum) CF -1 R Tradition Village Plan 2B 7/2/01 Project Title Date Special Features and Modeling Assumptions The local enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The local enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies oaseu on ine auequacy or me speciai jusurication ano oocumentation submirted. Plan Field The DHW System "AMERICAN G52 -75T75" Energy Factor = 0.510. An EF below 0.58 requires an R-1 2 External Blanket. The HVAC System "HVAC -1" must meet all CEC Criteria for a Zonally Controlled system serving only Sleeping Areas. HIGH MASS Design(see C -2R) - Verify Thermal Mass: 529 sqft Exposed Slab Floor, 3.50" thick at Master Suite/Bedroom 2 HIGH MASS Design(see C -2R) - Verify Thermal Mass:. 598 sqft Covered Slab Floor, 3.50" thick at Master Suite/Bedroom 2 The HVAC System "HVAC -2" must meet all CEC Criteria for a Zonally Controlled system serving only Living Areas. HIGH MASS Design(see C -2R) - Verify Thermal Mass: 1967 sqft Exposed Slab Floor, 3.50" thick at Ent/Djn/Kit/Liv/GIIry/Pwd1fLn The HVAC System "HVAC -3" must meet all CEC Criteria for a Zonally Controlled system serving only Sleeping Areas. HIGH MASS Design(see C -2R) - Verify Thermal Mass: 87 sqft Exposed Slab Floor, 3.50" thick at Guest Suite HIGH MASS Design(see C-211) - Verify Thermal Mass: 256 sqft Covered Slab Floor, 3.50" thick at Guest Suite HERS Required Verification These features must be confirmed and/or.tested by a certified HERS rater under thp suRe��vision of a CEC approved HERS PIUVIUVI. !I IV rlF-r%O I CILWI I I MbLUVI.Ul I IVIIL LI IV I IVIU VVI11KCILIVI I CIIIU UICIUIIVbLI%, IVbLIII!J UI UlCbC MUCIZOUMb WI I d I UF IF] %,r -or%. Uhe HVAL; System "HVAC -1" includes a Thermostatic Expansion Valve (TXV). An access door or removable panel must be and a certified HERS rater must visually verify the installation of the TXV. --PT—an providec, Field The HVAC System "HVAC -2" includes a Thermostatic Expansion Valve (TXV). An access door or removable panel must be and a certified HERS rater must visually verify the installation of the TXV. providel, The HVAC System "HVAC -3" includes a Thermostatic Expansion Valve (TXV). An access door or removable -�a—nel must be and a certified HERS rater must visually verify the installation of the TXV. providec, I Run Initiation Mm—e--UM/01 07:32:11 Run Code: 994084331 1 EnergyPro 3.0 By EnergySoft User Number: 3665 Job Number: Page: 5 of 46 0 40 Mandatory Measures Checklist: Residential MF -1 R NOTE:- Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. Items marked with an asterisk (*) may be superseded by more stringent compliance requirements listed on the Certificate of Compliance. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. DESCRIPTION Instructions: Check or initial applicable boxes or enter N/A if not applicable. DESIGNER ENFORCEMENI Building Envelope Measures 150(a): Minimum R-1 9 ceiling insulation in wood frame assembly, or equivalent U -value. 150(b): Loose fill insulation manufacturer's labeled R -Value. 150(c): Minimum R-1 3 wall insulation in wood framed walls or equivalent U -value in metal frame walls (does not apply to exterior mass walls). 150(d): Minimum R-1 3 raised floor insulation in framed floors. 150(l): Slab edge insulation - water absorption rate — 0.3%, water vapor transmission rate — 2.0 perm/inch. §118: Insulation specified or installed meets insulation quality standards. Indicate type and form. §116-17: Fenestration Products, Exterior Doors and Infiltration/Exfiltration Controls 1. Doors and windows between conditioned and unconditioned spaces designed to limit air leakage. 2. Fenestration products (except field fabricated) have label with certified U -Factor, certified SHGC, and infiltration certification. 3. Exterior doors and windows weatherstripped; all joints and penetrations caulked and sealed. F—] §150(g): Vapor barriers mandatory in Climate Zones 14 and 116 only. X§ 150(0: Special infiltration barrier installed to comply with Section 151 meets Commission quality standards. FX -1 § 1 50(e): Installation of Fireplaces, Decorative Gas Appliances and Gas Logs. 1. Masonry and factory -built fireplaces have closable doors, outside air intake with damper and control, and flue damper and control; 2. No continuous burning gas pilots allowed. Space Conditioning, Water Heating and Plumbing System Measures X§110-13: HVAC equipment, water heaters, showerheads and faucets certified by the Commission. [X] § 1 50(h): Heating and/or cooling loads calculated in accordance with ASH RAE, SMAC NA or ACCA. §150(i): Setback thermostat on all applicable heating and/or cooling systems. §1500): Pipe and Tank Insulation 1. Storage gas water heaters with less than 0.58 energy factor shall be externally wrapped with R-12. 2. First 5 feet of pipes closest to water heater tank, non -recirculating systems, insulated (R4 or greater) 3. Back-up tanks for solar system, unfired storage tanks, or other indirect hot water tanks have R-1 2 external insulation or R-1 6 combined internal/external insulation. 4. All buried or exposed piping insulated in recirculating sections of hot water systems. 5. Cooling system piping below 55 degrees F. insulated. 6. Piping insulating between heating source and indirect hot water tank. *§11 50(m): Ducts and Fans . All ducts and plenums installed, sealed and insulated to meet the requirements of the 1998 CMC Sections 601, 603, 604 and Standard 6-3; ducts insulated to a minimum installed level of R-4.2 or enclosed in conditioned space. Openings shall be sealed with mastic, tape aerosol sealant or other duct- closure system that meets the applicable requirements of UL1 81, UL1 81A, or UL1 81 B. If mastic or tape is used to seal openings greater than 1/4 inch, the combination of mastic and either mesh tape or tape shall be used. Building cavities shall not be used for conveying conditioned air. Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such tape is used in combination with mastic and drawbands. 2. Exhaust fans systems have back draft or automatic dampers. 3. Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated dampers. [X] §114: Pool and Spa Heating Systems and Equipment 1. Certified with 78% thermal efficiency, on-off switch, weatherproof instructions, no electric resistance heating, no pilot. 2. System is installed with at least 36" of pipe between filter and heater for future solar, cover for outdoor pools or spas. 3. Pool system has directional inlets and a circulation pump time switch. §115: Gas fired central furnaces, pool heaters, spa heaters or household cooking appliances have no continuously burning pilot light. (Exception: Non -electrical cooking appliances with pilot < 150 Btu/hr) Lighting Measures §1 50(k)l: Luminaires for general lighting in kitchens shall have lamps with an efficacy 40 lumenstwatt or greater for general lighting in kitchens. This general lighting shall be controlled by a switch on a readily accessible lighting control panel at an entrance to the kitchen. 1XI150(k)2: Rooms with a shower or bathtub must have either at least one luminaire with lamps with an efficacy of 40 lumenstwaft or greater switched at the entrance to the room or one of the alternative to this requirement allowed in Section 150(k)2.; and recessed ceiling fixtures are IC (insulation cover) approved. EnergyPro 3.o By EnergySoft User Number: 3665 Job Number: Page:6 0 Com puter Method Summary (Part 1 of 3) C -2R Tradition Village Plan 213 7/2/01 -Pro-je-cf I itle Date Tradition Golf lub La Quinta erojeCt A00reSS BREEZE AIR CONDITIONING (760) 346-0855 Documentation Author I etephone Computer Performance 15 U111P 0"L.V WL VU k OL, OUC V. V111PULCI 1 111CILU V"W Building Permit 9 Plan CheclUDate Field ChecWuate Source Energy Standard Use (kBtu/sf-yr) Design Space Heating 3.69 Space Cooling 36.62 Domestic Hot Water 8.29 Totals 48.61 Facing North Margin 0.028 Facing East Margin 0 Facing South Margin Facing West Margin MasterSuite/Bedroom 2 2.43 1.27 37.78 -1.16 01 1 8.30 -0. 1 2.64 1.05 36.69 -0.07 8.30 -0.01 3.10 0.59 36.08 0.54 8.30 -0.01 3.42 0.27 33.96 2.66 8.30 -0.0 48.51 0 . 1 0 47.63 0.98 47.48 1.12 r-45.68 .9�3 L7 1 L$ U�l L U NU COMIJILI ZZ) I his L;-ZK Summarizes the results ot a tour carainal orientation analysis. I ne pages triat tollow aescribe the tront tacing North occurence. This plan has been analyzed with identical features in all orientations. GENERAL INFORMATION Conditioned Floor Area: 3,437 Floor Construction Type: Slab Floor Building Type: Single Fam Detached Raised Floor Building Front Orientation: All Four Orientations Number of Dwelling Units: 1.00 Total Conditioned Volume: 36,856 Number of Stories: 1 Slab Floor Area: 3,437 BUILDING ZONE INFORMATION # of Thermostat Vent Zone Name Floor Area Volume Units Zone Type Type Hgt. Area HVAC -1 1,127 12.17 0.33 Sleeping SleepingStat 2 - n/a HVAC -2 1,967 21,59 0.67 Living LivingStat 2 rVa HVAC -3 343 3,08 0.10 Sleeping SleepingStat 2 n/a OPAQUE SURFACES Type Area U -Val - ---S-01`ar-- Act. Gains Azm. Tilt Y/N Form 3 Reference Location / Comments Roof 1,127 0.028 0 0 R-38 R of (R.38.2xl4.16) MasterSuite/Bedroom 2 Wall 81 0.059 0 90 R-21 Wall (W.21.2x6.16) MasterSuite/Bedroom 2 Wall 134 0.059 180 90 F] R-21 Wall (W.21.2x6.16) MasterS u ite/Bed room 2 Wall 548 0.059 270 90 F� R-21 Wall (W.21.2x6.16) MasterS u ite/Bed room 2 Roof 1,967 0.028 0 0 E] R-38 Roof (R.38.2xl4.16) Ent1Din/Kit/Liiv/Glry/P Wall 258 0.059 0 90 R-21 Wall (W.21.2x6.16) Ent/Din/Kit/Liiv/Glry/P Door 24 0.387 0 90 Solid Wood Door EnVDin/Kit/Liiv/Glry1P Wall 635 0.059 90 90 1 E] R-21 Wall (W.21.2x6.16) Ent/Din/Kit/Liiv/Glry/P Wall 326 0.059 180 90 R-21 Wall (W.21.2x6.16) Ent1Din/Kit/Liiv/Glrv/P Wall 402 0.059 270 90 R-21 Wall (W.21.2x6.16) Ent1Din/Kit1Liiv/Glry/P Roof 343 0.028 0 0 R-38 Roof (R.38.2xl4.16) Guest Suite Wall 144 0.059 0 90 R-21 Wall (W.21.2x6.16) Guest Suite Wall 137 0.059 90 90 F-] R-21 Wall (W.21.2x6.16) Guest Suite Wall 153 0.059 180 90 n R-21 Wall (W.21.2x6.16) Guest Suite F-1 F-1 F-1 F-1 F-1 F-1 F-1 F-1 1-1 Q F-1 F-1 Q F F-1 F-1 M F-1 F� F-1 F-1 El ID Run Initiation Time: 07/02/0107:32:11 Run Code: 994084331 EnergyPro 3.0 By EnergySoft User Number: 3665 Job Number: Page:7 of 46 Com puter Method Summary (Part 2 of 3) C -2R Tradition Village Plan 213 7/2/01 Project Title Date l-LNL5 I KA I IUN 5UKFAL;h5 U_ Act. Glazing Type Location/ # Type Area Factor SHGC Azm. Tilt Comments 1 Window Rear (South) 34.0 0.480 0.49 180 90 Sunair NonMtl Tinted MasterSuite/Bedroom 2 Y Window Rear (South) 7.1 0.460 0.49 180 90 Sunair NonMtl Tinted MasterSuite/Bedroom 2 Window Right (West) --6.-460 -0.49 270 90 Sunair NonMtl Tinted Masters u ite/Bed room 2 Window Right (West) --2.0 2.0 0.460 0.49 270 90 Sunair NonMtl Tinted MasterS u ite/Bed room 2 Window Right (West) -2.0 --6-.460 0.49 270 90 Sunair NonMtl Tinted MasterS u ite/Bed room 2 Window Right (West) 5.0 0.460 0.49 270 90 Sunair NonMtl Tinted Maste rS u ite/Bed room 2 Window Right (West) 16.0 0.460 0.49 270 90 Sunair NonMtl Tinted Maste rS u ite/Bed room 2 window Right (West) 32.0 0.480 0.49 --2-7-0 90 Sunair NonMtl Tinted MasterSuite/Bea-room2 Window Right -(West) 1-6.0 -0.460 -0.49 -270 -90 Sunair NonMt1 Tinted Maste rS u ite/Bed room 2 0- Window Right (West) 32.0 0.460 0.49 270 90 Sunair NonMt1 Tinted Maste rS u ite/Bed room 2 T1 Window Right (West) 6.0 0.460 0.49 270 90 Sunair NonMtl Tinted MasterS u ite/Bed room 2 1-2 Window Front (North) 34.0 0.480 0.49 0 -0 90 Sunair NonMtl Tinted -90 EnVDin/KiVLiiv/Glry/P T3 Window Front (North 16.0 0.460 0.49 Sunair NonMtl Tinted EnVDin/Kit/Liiv/Gl!y/P T4 Window Front (North) 32.0 0.480 --6.-460 0.49 0 90 Sunair NonMt1 Tinted EnVDin/Kit1Liiv/Glry/P i-5 Window Front (North) 1-6.0 0.49 -0 -90 Sunair NonMt1 TFn-ted- Ent/Din/Kit/Lii;V/Glry/P Window Left (East) 16.0 0.460 0.49 90 90 Sunair NonMtl Tinted EnVDin/KiVLiiv/Glry/P i-7 Window Left (East) 3.0 0.466- -0.49 90 90 Sunair NonMtl Tinted EnVDin/Kit/Li1v/Glry/P f _8 Window Left (East) 3-2.0 --6.-480 -0.49 -90 -90 Sunair NonMtl Tinted Ent/Din/Kit/Liiv1Glry/P f _9 Window Left 6.0 0.460 0.49 -90 -90 Sunair NonMt1 Tinted Ent/Din/Kit/Liiv/Glry/P Window Left (East) 32.0 0.460 0.49 90 90 Sunair NonMtl Tinted Ent1Din/Kit/Liiv1Glry/P Y1 Window Left (East) 6.0 0.460 0.49 90 90 Sunair NonMtl Tinted EnVDin/Kit/Liiv/Glry/P Y2 Window Left (East) 3-2.0 --6-.-480 -0.49 -90 -90 Sunair NonMtl Tinted EnVDin/Kit/Liiv/Glry/P r3 Window Left (East) 6.0 0.460 0.49 90 90 Sunair NonMtl Tinted EnVDin/Kit/Liiv/Glry/P Y4 Window Left (East) 1-6.0 -6-.-460 -0.49 -90 -90 Sunair NonMt1 Tinted EnVDin/KiVLiiv!Glry/P Y5 Window Left (East) 6.0 0.460 0.49 90 90 Sunair NonMtl Tinted Ent/Din/KiVLiiv/Glry/P Y6_ Window Left (East) 32.0 0.460 0.49 90 90 Sunair NonMtl Tinted EnVDin/KiVLiiv/Glry/P 27 window Left­---JE-a`§q -32-.0- -0748*0- ---V.-49- -W ---gU Sunair Non= I inted Lnt/Din1Kit1Liiv1Glry/P Y8- Window Rear (S-obuth) _ICT -0-.48T -T W ___W sunair NonMtl Tinted _E_nUD`ffin7KVUU -ivTGTr-y7P--- 2_9 Window Rear (South) 6-2.3 -6-.-460 -0.49 -180 -90 gunair NonMtl Tinted EnVDin/KiVLiiv/Glry/P INTERIOR AND EXTERIOR SHADING Window Overhang Left Fin Right Fin # Exterior Shade Type SHGC _R­gt.__VVa_- Len. Hgt. LExt. HEM. _15ist. Len. Hgt. _13i'sE. --fen. Hgt. 1 Bug Screen U.76 19ug Screen -076 - - Bug Screen -0.76 - - 'Bug Screen -0.76 - - 'Bug Screen -0.76 'Bug Screen -076 - - -7- 'Bug Screen 0.76 8- B-ug-S-creen -0-76- - Y Bug Screen -0.76 _1 0- Bug Screen 0.76 AT Bug Screen -0-M TZ ug creen -0 716- _fS Wmg-96-reen -0-M -80 -20 -20 -01 -20 -20 - - -1-if B-u-g S-c-reen -80 -40 -20 -01 -20 -20 - - TS ug Screen _076- _8_.0 _2_.0 -20 -0 1 -2-0 ___n - - T6 ug Screen -0-76- 177 Bug Screen 0.76 Ta ug Screen _0.T6_ ug Screen -0-.76- -26 95-gSic-reen - - - 0 -.TG - IT ug Screen __0_K Y2 Bug Screen -0.76 T3_ 'Bug Screen -076 Y4_ Bug Screen 0.76 Y5_ Bug Screen -076 Y6 'Bug Screen -076 TY Bug Screen 0.76 1_8 Bug Screen -0.76 -4-.2 -20 __F1 -20 -TO 29 Bug Screen -076 I Run Initiation Time: 07/02/01 07:32:11 Run Code: 994084331 I EnergyPro 3.0 By EnergySoft User Number. 3665 Job Number: Page: 8 of 46 Computer Method Summary (Part 2 of 3) C -2R Tradition Village Plan 2B 7/2/01 -P—roj-e-Cl Title Date FF-INILSTIKATION 5URFAGF:b U- Act. Glazing Type Location/ # Type Area Factor SHGC Azm. Tilt Comments 30 Window Left (East) 34.0 0.480 0.49 90 90 Sunair NonMtl Tinted Guest Suite INTERIOR AND EXTERIOR SHADING VVindow Overhang Left Fin Right Fin # Exterior Shade Type SHGC -R-gt—.--M-. Len. Hgt. LEx­t­.--REx-t. Dist. Len. Hgt. -M—st. Ee—nHjt- Bug 5creen 076�— Run Initiation Time: 07/02/0107:32:11 Ruh Code: 994084331 EnergyPro, 3.0 By EnergySoft User Number: 3665 Job Number: Page: 9 of 46 Computer Method Summary (Part 3 of 3) C -2R Tra'dition Village Plan 2B Insulation (attic, etc,) 7/2/01 rojeCt Title Factor R -Val. Date THERMAL MASS FOR HIGH MASS DESIGN Slab Perimeter 36 Area Thick. Heat Inside Location Type (sf) (in.) Cap. Cond. Form 3 Reference R -Val. Comments Concrete, Heavyweight 529 3.50 28 0.98 n/a 0 MasterSuite/Bedroom 2 / Slab on Grade Concrete, Heavyweight 598 Y50 28 0.98 n/a 2 MasterSuite/Bedroom 2 / Slab on Grade Concrete, Heavyweight 1,967 -5.50 28 0.98 n/a 0 Ent/Din/Kit/Liiv/Glry/P / Slab on Grade Concrete, Heavyweight 87 5.50 28 0.98 n/a 0 Guest Suite / Slab on Grade Concrete, Heayyweight 256 -5.50 28 0.98 n/a 2 Guest Suite / Slab on Grade PERIMETER LOSSES HVAC SYSTEMS Heating Equipment Minimum Distribution Type Type (furnace, heat Efficienc� and Location Duct Thermostat Location pump, etc.) (AFU E/HS F)(ducts/aftic, etc.) R -Value Type Comments Central Furnace 80% AFUE Ducts in Attic 4.2 Setback HVAC -1 Central Furnace 80 % AFUE Ducts in Attic 4.2 Setback HVAC -2 Central Furnace 80% AFUE Ducts in Attic Setback HVAC -3 0 Hydronic Piping System Name Pipe Pipe Insul. Length Diameter Thick. Cooling Equipment Type (air conditioner, heat pump, evap. cooling) Split Air Conditioner Split Air Conditioner Split Air Conditioner Minimum Duct Efficiency Location F2 Insulation (attic, etc,) Type Length Factor R -Val. Depth Location / Comments Slab Perimeter 36 0.76 0.0 0 MasterSu ite/Bed room 2 Slab Perimeter 61 6.7-6 —0.0 —0 sterS u ite/Bed room 2 Slab Perimeter 185 .76 0.0 —0 Ent/Din/Kit/Liiv/Giry/P Slab Perimeter 21 .76 0.0 0 Guest Suite Slab Perimeter 34 6.7-6 —0.0 —0 —est Suite HVAC SYSTEMS Heating Equipment Minimum Distribution Type Type (furnace, heat Efficienc� and Location Duct Thermostat Location pump, etc.) (AFU E/HS F)(ducts/aftic, etc.) R -Value Type Comments Central Furnace 80% AFUE Ducts in Attic 4.2 Setback HVAC -1 Central Furnace 80 % AFUE Ducts in Attic 4.2 Setback HVAC -2 Central Furnace 80% AFUE Ducts in Attic Setback HVAC -3 0 Hydronic Piping System Name Pipe Pipe Insul. Length Diameter Thick. Cooling Equipment Type (air conditioner, heat pump, evap. cooling) Split Air Conditioner Split Air Conditioner Split Air Conditioner Minimum Duct Efficiency Location Duct (SEER) (attic, etc,) R -Value 14.0 SEER Ducts in Attic 4.2 15.8 SEER Ducts in Attic 4.2 12.1 SEER Ducts in Attic 4.2 Thermostat Location / Type Comments Setback HVAC -1 Setback HVAC -2 Setback HVAC -3 WATER HEATING SYSTEMS Ratedl Tank Energy Fact! 1 Tankinsul. Water Heater Water Heater Distribution #in Input Cap. or Recovery Standby R -Value System Name Type Type Syst. (Btu/hr) (gal) Efficiency Loss (%) Ext. AMERICAN G52 -75T75 Small Gas RecircrTime+Temp 1 74,500 75 0.51 n/a 12 For small gas storage (rated input <= 75000 Btu/hr), electric resistance and heat pump water heaters, list energy factor. For large gas storage water heaters (rated input > 75000 Btu/hr), list Rated Input, Recovery Efficiency and Standby Loss. For instantaneous gas water heaters, list Rated Input, and Recovery Efficiency. REMARKS Run Initiation Time: 07/02/01 07:32:11 Run Code: 994084331 EnergyPro 3.0 By EnergySoft User Number: 3665 Job Number: Page: 10 of 46 0 11 Com puter Method Summary (Addendum) C2 -R Tradition Village Plan 2B 7/2/01 Project Title -155te Special Features and Modeling Assumptions The local enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The local enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies Daseu on ine aoequacy Or ine speciai justaication ano aocumentation SUDMInea. Plan Field The DHW System "AMERICAN G52 -75T75" Energy Factor = 0.510. An EF below 0.58 requires an R-1 2 External Blanket. The HVAC System "HVAC -1" must meet all CEC Criteria for a Zonally Controlled system serving only Sleeping Areas. HIGH MASS Design(see C -2R) - Verify Thermal Mass: 529 sqft Exposed Slab Floor, 3.50" thick at Master Suite/Bedroom 2 HIGH MASS Design(see C -2R) - Verify Thermal Mass: 598 sqft Covered Slab Floor, 3.50" thick at Master Suite/Bedroom 2 The HVAC System "HVAC -2" must meet all CEC Criteria for a Zonally Controlled system serving only Living Areas. HIGH MASS Design(see C -2R) - Verify Thermal Mass: 1967 sqft Exposed Slab Floor, 3.50" thick at Ent/Din/Kit/Liv/GIIry/PwdFfLn The HVAC System "HVAC -3" must meet all CEC Criteria for a Zonally Controlled system serving only Sleeping Areas. HIGH MASS Design(see C -2R) - Verify Thermal Mass: 87 sqft Exposed Slab Floor, 3.50" thick at Guest Suite HIGH MASS Design(see C -2R) - Verify Thermal Mass: 256 sqft Covered Slab Floor, 3.50" thick at Guest Suite HERS Required Verification These features must be confirmed and/or tested by a certified HERS rater under the s ion of a CEC approved HERS provider. The HERS rater must document the field verification and diagnostic testing=e measures on a form CF -6R. I Plan I Field 1he HVAL; system "HVA(; -1- includes a Thermostatic Expansion valve (TAV). An access door or removable panel must be and a certified HERS rater must visually verify the installation of the TXV. proviaec, The HVAC System "HVAC -2" includes a Thermostatic Expansion Valve (TXV). An access door or removable panel must be and a certified HERS rater must visually verify the installation of the TXV. providec, The HVAC System "HVAC -3" includes a Thermostatic Expansion Valve (TXV). An access door or removable panel must be and a certified HERS rater must visually verify the installation of the TXV. providec, I Run Initiation Time: 07102101 07:32:11 Run Code: 994084331 EnergyPro 3.0 By EnergySoft User Number: 3665 Job Number: Page: 11 of 46 INSTALLATION CERTIFICATE (Part 1 of 7) CF -6R -site Address Permit Number An installation certificate is required to be posted at the building site or made available for all appropriate inspections. (The information provided on this form is required; however, use of this form to provide the information is optional.) After completion of final inspection, a copy must be provided to the building department (upon request) and the building owner at occupancy, per Section 10-1 03(b). HVAC SYSTEMS: Heating Equipment Equip. # of Efficiency, Duct Duct or Heat' ng Heat'99 Type(pkg CEC Certified Mfr Name Identical (AFUE, etc.) Location Piping Load Ca acity heat pump� & Model Number Systems [>= CF -1 R Value) (attic, etc.) R -Value (Btu/hr) (Bfu/hr) Cooling Equipment Equip. CEC Certified Compressor # of Efficiency' Duct Cooling Cooling Type (pkg., Unit Mfr Name & Identical (SEER, etc.) Location Duct or Load Capacity heat pump) Model Number Systems [>= CF -1 R Value] (attic, etc.) R -Value (Btu/hr) (BILAr) T. >-- -reads Greater Than or Equal to. 1, the undersigned, verify that equipment listed above is: (1) the actual equipment installed; (2) equivalent to or more efficient than that specified in the certificate of compliance (Form CF -1 R) submitted for compliance with the Energy Efficiency Standards for residential buildings; and (3) the equipment meets or exceeds the appropriate requirements for manufactured devices (from the Appliance Efficiency Regulations or Part 6), where applicable. Signature, Date Installing Subcontractor (Co. Name) OR General Contractor (Co. Name) OR Owner WATER HEATING SYSTEMS: CEC Certified Distribution If Recir- # of Rated2 Tank Effi-2 2 External Heater Mfr Name Type Std, culation, Identical Input (kW Volume ciency Standby Insulation Type & Model Number Point -41' -Use) Control Type Systems or Btulhr) Gallons (EF, RE) Loss I(%) R -Value 2 For small gas storage (rated input of less than or equal to 75,000 Btu/hr), electric resistance and heat pump water heaters, list Energy Factor. For large gas storage water heaters (rated input of greater than 75,000 Btu/hr), list Recovery Efficiency, Standby Loss and Rated Input. For instantaneous gas water heaters, list Recovery Efficiency and Rated Input. 3 R-12 external insulation is mandatory for storage water heaters with an energy factor of less than 0.58. Faucets & Shower Heads: All faucets & showerheads installed are certified to the Commission, pursuant to Title 24, Part 6, Section 111 1, the undersigned, verify that equipment listed above my signature is: (1) is the actual equipment installed; (2) equivalent to or more efficient than that specified in the certificate of compliance (Form CF -1 R) submitted for compliance with the Energy Efficiency Standards for residential buildings; and (3) equipment that meets or exceeds the appropriate requirements for manufactured devices (from the Appliance Efficiency Regulations or Part 6), where applicable. Signature, Date Installing Subcontractor (Co. Name) OR General Contractor (Co. Name) OR Owner COPY TO: Building Department HERS Provider (if applicable) Building Owner at Occupancy EnergyPro 3.0 By EnergySoft User Number: 3665 Job Number: Page: 12 of 46 INSTALLATION CERTIFICATE (Part 2 of 7) CF -6R te ddress -15-e-rm-TR-umber FENESTRATION / GLAZING: Product Ll- Product Interior or Value 1 SHGC' Exteror Shading (=<CF -1 R (=< CF -1 R # of Quantity Sguare Device or Comments/ Manufacturer/Brand Name value)2 valuey Panes (Optional) Feet Overhang Special Features ROUP LIKE PROD 1 . 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. 14. 15. 1. Manufactured Fenestration products use the values from the product label. Field fabricated fenestration products use the default values from Section 116 ofthe Energy Efficiency Standards. 2.s:nstalled U -value must be less than or equal to values from CF -11R. lnstalled.SHGC must be less than or equal to values from CF -1 R, or a shading device (interior, exterior or overhang) is in alled as specified an the CFAR. Altematively. installed weighted average U -values for the total fenestration area are less than or equal to values from CFAR. 1, the undersigned, verify that the fenestration/glazing listed above my signature (1) is the actual fenestration product installed; (2) is equivalent to or has a lower U -value and lower SHGC than that specified in the certificate of compliance (Form CF -1 R) submitted for compliance with the Energy Efficiency Standards for residential buildings; and (3) the product meets or exceeds the appropriate requirements for manufactured devices (from Part 6), where applicable. Item #s Signature, Date (if applicable) Item #S M�gnature, Date (if applicable) Item #s -6�ignature, Date (if applicable) Installing ubcontractor ( o. Name) OR General Contractor (Co. Name) OR Owner OR Window Distributor Installing Subcontractor (Co. Name) OR General Contractor (Co. Name) OR Owner OR Window Distributor Installing Subcontractor (Co. Name) OR General Contractor (Co. Name) OR Owner OR Window Distributor COPY TO: Building Department HERS Provider (if applicable) Building Owner at Occupancy lEnergyPro 3.0 By EnergySoft User Number: 3665 Job Number: Page: 13 of 46 0 0 INSTALLATION CERTIFICATE (Part 3 of 8) CF -6R Address — Permit Number DUCT LEAKAGE AND DESIGN DIAGNOSTICS Ej DUCT LEAKAGE REDUCTION Pressurization Test Results (CFM @ 25 PA) Test Leakage (CFM) Fan Flow If Fan Flow is Calculated as 400 cfm/ton x number of tons, or as 21.7 x Heating Capacity in Thousands of Btu/hr, enter calculated value here If fan flow is measured, enter measured value here Leakage Fraction = Test Leakage/(Measured or Calculated Fan Flow) Pass if leakage fraction — 0.06 ElFor AEROSOL TYPE SEALANTS ONLY - The following diagnostic testing was completed: Duct Fan Pressurization at rough -in measured leakage (CFM) ElYes El No R. Pressure pan test or House pressurization test ElYes F No F Visual Inspection of Duct Connections [:] THERMOSTATIC EXPANSION VALVE (TXV) El El Pass Fall 1:1 0 Pass Fail Yes n No Thermostatic Expansion Valve is installed and Access is provided for inspection Yes is a pass F-1 F-1 THERMOSTATIC EXPANSION VALVE (TXV) Pass Fail Yes R No ACCA Manual D Design calculations have been completed, Duct Design is on the plans and duct installation matches plans 2. F-] Yes F-] No TXV is installed or Fan flow has been verified. If no TXV, verified fan flowmatches design from CFAR. Measured Fan Flow Yes for both 1 and 2 is a Pass F1 1-1 Pass Fall F-1 1, the undersigned, verify that the above diagnostic test results and the work I performed associated with the test(s) is in conformance with the requirements for compliance credit. [The builder shall provide the HERS provider a copy of the CF -6R signed by the builder employees or sub -contractors certifying that diagnostic testing and installation meet the requirements for compliance credit.] Tests Signature, Date nstalling Subcontractor o. Name) Performed OR General Contractor ( o. Name) OR Owner COPY TO: Building Department HERS Provider (if applicable) Building Owner at Occupancy lEnergyPro 3.0 By EnergySoft User Number: 3665 Job Number: Page: 14 of 46 0 INSTAL,LATI.ON CERTIFICATE (Part 3 of 8) Site Address Permit Number DUCT LOCATION AND AREA REDUCTION DIAGNOSTICS DUCT IN CONDITIONED SPACE ElYes F-1 No Duct in conditioned space criteria matches CF -1R 1-1 n Yes is a pass Pass Fail REDUCED DUCT SURFACE AREA Measured duct exterior surface area in the following unconditioned duct locations (square feet): Attics Crawlspaces Basements Other (e.g., garages, etc.) F-1 Yes n No Duct surface area matches CF -1R? Yes is a pass El F-1 Pass Fall CF -6R F—] 1, the undersigned, verify that the duct surface area and duct locations claimed for duct surface area reductions and duct location improvements beyond those covered by default assumptions match those on the plans. [The builder shall provide the HERS provider a copy of the CF -6R signed by the builder employees or sub -contractors certifying that diagnostic testing and installation meet the requirements for compliance credit.] Tests Signature, Date InstaT ng SubcontractorAGo. Name Performed OR General Contractor ( o. Name) R Owner COPYTO: Building Department HERS Provider (if applicable) Building Owner at Occupancy IEnergyPro 3.0 By EnergySoft User Number: 3665 Job Number: Page: 15 of 46 INSTALLATION CERTIFICATE (Part 4 of 7) CF -611 ite AdElress _P­e_rffiT1R_umber BUILDING ENVELOPE LEAKAGE DIAGNOSTICS ENVELOPE SEALING INFILTRATION REDUCTION Diagnostic Testing Results Building Envelope Leakage (CFM @ 50 Pa) as measured by Rater is measured envelope leakage less than or equal to the required level from CF1 R? Yes No 1-1 1-1 Is Mechanical Ventilation shown as required on the CF -1 R? Yes No 2a. F-1 F-1 If Mechanical Ventilation is required on th . e CF -1 R (Yes on Line 2), has it been Yes No installed? 2b. [-] F-] Check this box yes if mechanical ventilation is required (Yes in line 2) and Yes No ventilation fan watts are no greater than shown on CF -1 R. Measured Wafts 3. F-] n Check this box yes if measured building infiltration (CFM @ 50 Pa) is greater than Yes No the CFM @ 50 values shown for an SLA of 1.5 on CF -1 R (If this box is checked no, mechanical ventilation is required.) 4. Fj F] Check this box yes if measured building infiltration (CFM @ 50 Pa) is less than the Yes No CFM @ 50 values shownfor an SLA of 1.5 on CF -1 R, mechanical ventilation is installed and house pressure is greater than minus 5 Pascal with all exhaust fans operating. Pass if: 11 0 a. Yes in line 1 and line 3, or Pass Fail b. Yes in line 1 and 2, 2a, and 2b, or c. Yes in line 1 and Yes in line 4. Otherwise Fail. 1, the undersigned, verify that the building envelope leakage meets the requirements claimed for building leakage reduction below default assumptions as used for compliance on the CF -1 R. This is to certify that the above diagnostic test results and the work I performed associated with the test(s) is in conformance with the requirements for compliance credit. [The builder shall provide the HERS provider a copy of the CF -6R signed by the builder employees or sub -contractors certifying that diagnostic testing and installation meet requirements for compliance credit.] I ests; Signature, Date -Installing Subcontractor Co. Name) Performed OR General Contractor (Co. Name) OR Owner COPY TO: Building Department HERS Provider (if applicable) Building Owner at Occupancy I EnergyPro 3.0 By EnergySoft User Number: 3665 Job Number: Page: 16 of 46 INSTALLATION CERTIFICATE (Part 6 of 7) CF -6R e ddress Fl—ermit Number The following is an explanation of many of the input values required on this form: WATER HEATING SYSTEMS Distribution Systems: Refer to Residential Manual for more details. Standard: Standard - Supply prssure based system, no pumps Pipe Insulation: Pipe Insulation on all 3/4 -inch pipes POU/HWR: Point of Use/Hot Water Recovery System Recirc/NoControl: Recirculation loop with no controls Recirc/Timer: Recirculation loop with a timer Recirc/Temp: Recirculation loop with temperature control Recirc/Time + Temp: Recirculation loop with a timer and temperature control Recirc/Demand: Recirculation loop with demand control Water Heater Type Windows, sliding glass doors, french doors, skylights, garden windows, and Information Needed any door with more than one square foot of glass Operator Type; Energy Factor Recovery Efficiency Standby Loss Rated Input Storage Gas, Oil or Electric Yes No No No Heat Pump Yes No No No Instantaneous Gas No Yes No No Instantaneous Electric Yes No No No Large Storage Gas No Yes Yes Yes Indirect Gas (Boiler) No Yes (AFUE) No Yes 0 FENESTRATION / GLAZING Fenestration: Windows, sliding glass doors, french doors, skylights, garden windows, and any door with more than one square foot of glass Operator Type; Slider, hinged, fixed U -Value: Installed U -Value must be less than or equal to value from CF -1 R OR Installed weighted average U -Value for the total fenestration area is less than or equal to value from CF -1 R SHGC: Installed SHGC must be less than or equal to value from CF -1 R OR Installed SHGC for the total fenestration area is less than or equal to value from CF -1R OR An interior shading device, overhang, or exterior shading device is installed consistent with the CF -1 R Shading Device: Include when the building complied using an interior shading device: blinds, opaque roller shades, blinds (do not list draperies), an exterior shading device: woven sunscreen, louvered sunscreen, low sun angle sunscreen, roll -down awning, roll -down blinds or slats (do not list bug screen), or an overhang (include depth in feet) lEnergyPro 3.0 By Energysoft User Number: 3666 Job Number: Page: 17 of 46 1 INSTALLATION CERTIFICATE (Part 7 of 7) CF -6R 9 - Site Address — Permit Number 0 0 The following is an explanation of many of the input values required on the Diagnostic portion of this form (page 3 of 6): TYPE OF CREDIT Refer to Residential Manual Chapters 4 and 5 for more details: Reduced Duct Surface Calculated as the outside area of the duct. Areas must be measured and Area: verified by HERS rater. Improved Duct Location: Supply duct located in other than attic, as verified by location of registers (does not require HERS rater verification). Catastrophic Leakage: Pressure pan test reading must be less than 1.5 Pascal at a house pressure of 25 Pascal. TXV: Access cover required to facilitate verification. Infiltration Reduction: Infiltration is measured without mechanical ventilation operating. Mechanical ventilation is required for very tight house construction when credits for infiltration reduction using diagnostic testing are beng used for achieving compliance. These very tight houses are defined as those with SLA of less than 1.5. The compliance documentation (CF -1 R) will contain the measured CFM target value from a blower door test at 50 Pascal pressure difference that represents this SLA of 1.5. Mechanical ventilation is also required if the builder chooses to design the building to use mechanical ventilation and claims a credit for infiltration below an SLA of 3.0. The compliance documentation (CF -1 R) will contain the measured CFM target value that represents this 3.0 SLA. If the builder claims credit in a design for infiltration reduciton that is at an SLA of 3.0 or higher, and the actual measured SLA is 1.5 or greater, then mechanical ventilation is not required. If the SLA in this case were below 1.5, then mitigation (such as mechanical ventilation) would be required. lEnergyPro 3.0 By Energysoft User Number: 3665 Job Number: Page: 18 of 46 -1 0 IVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME DATE Tradition Village Plan 2B 7/2/01 SYSTEM NAME FLOOR AREA HVAC -1 1,127 Number of Systems 11COILHTG.PEAK1 Heating System Output per System 88,000 Total Output (Btuh) 88,000 Output (Btuh/sqft) 78.1 Cooling System Output per System 50,500 Total Output (Btuh) 60,500 Total Output (Tons) 4.2 Total Output (Btuh/sqft) 44.8 Total Output (sqft[Ton) 267.8 Air System CFM per System 1,600 Airflow (cfm) 1,600 Airflow (cfm/sqft) 1.42 Airflow (cfm/Ton) 380.2 Outside Air (%) 0.0 Outside Air (cfm/sqft) 0.00 Note: values above niven at ARI conditions 26.0 OF 69.4 OF Outside Air 0 cfm Supply Fan 1600 cfm 69.4 OF Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COILCOOLINGPEAK 11COILHTG.PEAK1 CFMISensiblel Latent 11CFM1 SensUe 1 23,5201 4,83� LENNOX HS21-048-IP 41,584 0 Total Adjusted System Output 41,5841 ----0] (Adjusted for Peak Design Conditions) I TIME OF SYSTEM PEAK F Aug 2 pmi KIL;b (Airstream i emperatures at i ime OT mea 69.4 OF 121.1 OF Heating Coil Return Air Ducts RIGS (Airstream I emperatures at Time of Co; 11.0 / 77.6 OF 74.6 / 59.9 OF 74.6 / 59.9 OF 0 50.2 / 49.1 OF Outside 0 cfm 74.6/59.9 0 F Supply Fan Cooling Coil 1600 cfm k Return Air Ducts Y 88,000 88,0001 Jan 12 am� Supply Air Ducts 120.5 OF ROOKA-S] 70.0 OF Supply Air Ducts k�, 50.8 / 49.3 OF 43.1% R.H. ROOMS 1 74.0 / 59.7 OF EnergyPro 3.0 By EnergySoft User Number: 3665 Job Number: Page: 20 of 46 21,382 4,83 379 0 20,369 0 1,069 1,018 0 0 0 0 0 0 1,069 1,018 1 23,5201 4,83� LENNOX HS21-048-IP 41,584 0 Total Adjusted System Output 41,5841 ----0] (Adjusted for Peak Design Conditions) I TIME OF SYSTEM PEAK F Aug 2 pmi KIL;b (Airstream i emperatures at i ime OT mea 69.4 OF 121.1 OF Heating Coil Return Air Ducts RIGS (Airstream I emperatures at Time of Co; 11.0 / 77.6 OF 74.6 / 59.9 OF 74.6 / 59.9 OF 0 50.2 / 49.1 OF Outside 0 cfm 74.6/59.9 0 F Supply Fan Cooling Coil 1600 cfm k Return Air Ducts Y 88,000 88,0001 Jan 12 am� Supply Air Ducts 120.5 OF ROOKA-S] 70.0 OF Supply Air Ducts k�, 50.8 / 49.3 OF 43.1% R.H. ROOMS 1 74.0 / 59.7 OF EnergyPro 3.0 By EnergySoft User Number: 3665 Job Number: Page: 20 of 46 0 1HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME DATE Tradition Village Plan 2B 7/2/01 SYSTEM NAME FLOOR AREA HVAC -2 1,967 lNumber of Systems 42,839 Heating System Output per System 70,000 Total Output (Btuh) 140,000 Output (Btuh/sqft) 71.2 Cooling System Output per System 38,000 Total Output (Btuh) 76,000 Total Output (Tons) 6.3 Total Output (Btuh/sqft) 38.6 Total Output (sqft[Ton) 310.6 Air System CFM per System 1,200 Airflow (cfm) 2,400 Airflow (cfm/sqft) 1.22 Airflow (cfm/Ton) 378.9 Outside Air 0.0 Outside Air (cfm/sqft) 0.00 Note: values above given at ARI conditions 26.0 OF 69.2 OF Outside Air 0 cfm Supply Fan 2400 cfm 69.2 OF Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COILCOOLINGPEAK 11COILHTG.PEAK CFMISensiblel Latent 11CFM 47,123T 8,5472 HVAC EQUIPMENT SELECTION LENNOX HS21-036-1P 62,742 130 Total Adjusted System Output 62,7421 =1 30 (Adjusted for Peak Design Conditions) I TIME OF SYSTEM PEAK F Aug 2 pml KiLob (Airstream iei 69.2 OF 124.0 OF Heating Coil n 140,000 140,0001 Ja 30� Supply Air Ducts (A 123.2 OF ROOMS 70.0 OF Return Air Ducts I 11.0 / 77.6 OF 74.8 160.2 OF 74.8 / 60.2 OF = 50.3 / 49.1 OF Outside Air 0 cfm 74.8 / 60.2 OF Supply Fan Cooling Coil 2400 cfm �, Return Air Ducts Y Supply Air Ducts 51.1 / 49.5 OF 43.8% R.H. ROOMS 1 74.0 / 59.9 OF I EnergyPro 3.0 By EnergySoft User Number: 3665 Job Number: Page: 21 of 46 1 42,839 8,542 718 40,680 0 2,142 2,034 0 0 0 0 0 0 0 2,142 2,034 47,123T 8,5472 HVAC EQUIPMENT SELECTION LENNOX HS21-036-1P 62,742 130 Total Adjusted System Output 62,7421 =1 30 (Adjusted for Peak Design Conditions) I TIME OF SYSTEM PEAK F Aug 2 pml KiLob (Airstream iei 69.2 OF 124.0 OF Heating Coil n 140,000 140,0001 Ja 30� Supply Air Ducts (A 123.2 OF ROOMS 70.0 OF Return Air Ducts I 11.0 / 77.6 OF 74.8 160.2 OF 74.8 / 60.2 OF = 50.3 / 49.1 OF Outside Air 0 cfm 74.8 / 60.2 OF Supply Fan Cooling Coil 2400 cfm �, Return Air Ducts Y Supply Air Ducts 51.1 / 49.5 OF 43.8% R.H. ROOMS 1 74.0 / 59.9 OF I EnergyPro 3.0 By EnergySoft User Number: 3665 Job Number: Page: 21 of 46 1 1HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY I I PROJECT NAME DATE Tradition Village Plan 213 712/01 SYSTEM NAME FLOOR AREA HVAC -3 343 Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COILCOOLINGPEAK ICOILHTG.PEAK CIFM I Sensiblel Latent I CFM I Sensible 1 6,662� ::17,277] LENNOX HS26-018-2P 15,545 0 35,000 Total Adjusted System Oy.tput 15,5451 0] 1 35,0001 (Adjusted for Peak Design Conditions) I TIME OF SYSTEM PEAK Aug 2 pm Jan 12 am] PLA I INU bY5 I LIM! FbYL;HKUlMl1= I Klt;b (Airstream i emperatures at i ime OT meating I-eaK) 26.0 OF 69.4 OF 69.4 OF 124.3 OF 30 Supply Air DuctsS Outside Air 0 CfM MW 1 123.7 OF Supply Fan Heating Coil 600 cfm. ROOWS] 70.0 OF 69.4 OF I 11.0 / 77.6 OF )1, Outside Air 0 cfm 74.5/59.5 0 F * � 4 �, Return Air Ducts `L4 m iemi)eratures 74.5 / 59.5 OF 74.5 159.5 OF 50.1 / 49.0 OF .#�� � 0 Supply Fan Cooling Coil 600 cfm 6, Return Air Ducts 4 Supply Air Ducts 4 50.6 / 49.2 OF 41.8% R.H. ROOMS 1 74.0 / 59.3 OF EnergyPro 3.0 By EnergySoft User Number: 3665 Job Number: Page: 22 of 46 6,056 1,277 125 7,128 0 303 356 0 0 0 0 0 0 0 0 303 356 1 6,662� ::17,277] LENNOX HS26-018-2P 15,545 0 35,000 Total Adjusted System Oy.tput 15,5451 0] 1 35,0001 (Adjusted for Peak Design Conditions) I TIME OF SYSTEM PEAK Aug 2 pm Jan 12 am] PLA I INU bY5 I LIM! FbYL;HKUlMl1= I Klt;b (Airstream i emperatures at i ime OT meating I-eaK) 26.0 OF 69.4 OF 69.4 OF 124.3 OF 30 Supply Air DuctsS Outside Air 0 CfM MW 1 123.7 OF Supply Fan Heating Coil 600 cfm. ROOWS] 70.0 OF 69.4 OF I 11.0 / 77.6 OF )1, Outside Air 0 cfm 74.5/59.5 0 F * � 4 �, Return Air Ducts `L4 m iemi)eratures 74.5 / 59.5 OF 74.5 159.5 OF 50.1 / 49.0 OF .#�� � 0 Supply Fan Cooling Coil 600 cfm 6, Return Air Ducts 4 Supply Air Ducts 4 50.6 / 49.2 OF 41.8% R.H. ROOMS 1 74.0 / 59.3 OF EnergyPro 3.0 By EnergySoft User Number: 3665 Job Number: Page: 22 of 46 IROOM LOAD SUMMARY Tradition Village Plan 213 7/2101 SYSTEM NAME FLOOR AREA HVAC -1 1,127 [ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK ZONENAME ROOM NAME Mult. CFM SENSIBLE LATENT CFM SENSIBLE LATENT CFM SENSIBLE MasterSuite/Bedroom 2 Master Suite/13edroom 2 1 867 21,382 4,831 867 21,382 4,831 379 20,369 PAGE TOTAL 1 8671 21,3821 4,831]1 3791 20,369 TOTAL 1 8671 21,3821 4,831]1 3791 20,3769 I Energypro 3.0 By Energysoft User Number: 3665 Job Number: Page:23 of 46 1 IROOM LOAD SUMMARY ::1 I EnergyPro 3.0 By EnergySoft User Number: 3665 Job Number: Page: 24 of 46 PROJECT NAME Tradition Village Plan 213 DATE 712/01 SYSTEM NAME HVAC -2 FLOOR AREA 1,967 IROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK ZONENAME ROOM NAME Mult. CFM SENSIBLE LATENT CFM SENSIBLE LATENT CFM SENSIBLE Ent/Din/KiVLi1v/GIry/P Enwi n/K1VLivTGTFr—y1P—wdr7.n 1 1,759 42,839 8,542 1,759 42,839 8,542 718 40,680 t F-1— PAGE TOTAL 1 1,7591 42,8391 8,542]1 7181 40,680 TOTAL 1 1,7591 42,8391 8,542 1� 7181 40,680 I EnergyPro 3.0 By EnergySoft User Number: 3665 Job Number: Page: 24 of 46 is a 41 IROOM LOAD SUMMARY PROJECT NAME Tradition Village Plan 213 DATE 7/2/01 SYSTEM -NAME HVAC -3 FLOOR AREA 343 IROOM LOADMIMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK ZONENAME ROOM NAME Mult. CFM SENSIBLE LATENT CFM SENSIBLE LATENT CFM SENSIBLE Guest Suite Guest Suite 1 243 6,056 1,277 243 6,056 1,277 125 7,128 PAGE TOTAL 1 2431 6,0561 1,27711 1251 7,12�8] TOTAL 1 2431 6, 1 1251 7, I EnergyPro 3.0 By EnergySoft User Number: 3665 Job Number: Page:25 of 46 1 ROOM HEATING PEAK LOADS *!Project Title Date Tradition Village Plan 2B �7/2/01 Room Information Design Conditions Room Name Master Suite/Bedrwn 2 Time of Peak Jan 12 am Floor Area 1,127 Outdoor Dry Bulb Temperature 26 OF Indoor Dry Bulb Temperature 70 OF Conduction Area U -Value AT OF Btu/hr 0 Items shown with an asterisk (*) denote conduction through an interior surface to another room. Page Total: 10,8701 Infiltration: x [::� x XF --- 1-0.80] XF-- —1.0-01 / 6 x Air Sensible Area t—e1Ii—ng—R­ei­g-Rt ACH 6T Fraction TOTAL HOURLY HEAT LOSS FOR ROOM 20,36791 EnergyPro 3.0 By EnergySoft User Number: 3665 Job Number: Page: 26 of 46 1,127.0 X X X x X x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x 0.0280 x x X x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x 44.0 1,389 762.9 0.0592 44.0 1,988 66.0 0.4800 44.0 1,394 88.1 0.4600 44.0 1,783 perimeter 97.0 44.5 4,316 E-- I I Items shown with an asterisk (*) denote conduction through an interior surface to another room. Page Total: 10,8701 Infiltration: x [::� x XF --- 1-0.80] XF-- —1.0-01 / 6 x Air Sensible Area t—e1Ii—ng—R­ei­g-Rt ACH 6T Fraction TOTAL HOURLY HEAT LOSS FOR ROOM 20,36791 EnergyPro 3.0 By EnergySoft User Number: 3665 Job Number: Page: 26 of 46 r-1 ROOM HEATING PEAK LOADS I Project Title Dat Tradition Village Plan 2B �7/2/01 Room Information Design Conditions Room Name EntfDin/KitfU%dGllry/Pmdr/Ln Time of Peak Jan 12 am Floor Area 1,967 Outdoor Dry Bulb Temperature 26 OF Indoor Dry Bulb Temperature 70 OF Conduction Area U -Value AT OF Btu/hr R-38 Roof (R.38.2x14.16) R-21 Wall (W.21.2x6.16) Solid Wood Door Sunair NonMtl Tinted Sunair NonMtl Tinted Slab -On -Grade 1,967.0 X X X x X x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x 0.0280 x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x 44.0 2,424 1,620.7 0.0592 44.0 4,222 24.0 0.3872 44.0 409 196.0 0.4800 44.0 4,140 217.3 0.4600 44.0 4,398 perimeter 185.0 44.5 8,232 Items shown with an asterisk (') denote conduction through an interior surrace to another room. Page Total: Infiltration: x x XF- 10.-9ijxF---1-7.00 /6 x 1.00 �e. . Air sensible Area Ce-, Fn—gWe,-gKt ---ACR-- ILT Fraction ---j TOTAL HOURLY HEAT LOSS FOR ROOM _740,680 I EnergyPro 3.0 By EnergySoft User Number: 3665 Job Number: Page: 27 of 46 1 r--1 L'A 0 I ROOM HEATING PEAK LOADS Project Title Date Tradition Village Plan 213 �7/2/01 Room Information Design Conditions Room Name Guestsuite Time of Peak Jan 12 am Floor Area 343 Outdoor Dry Bulb Temperature 26 OF Indoor Dry Bulb Temperature 70 OF Conduction Area U -Value AT 0 F Btu/hr Items shown with an asterisk (*) denote conduction through an interior surface to another room. Page Total: Infiltration: x x x 1 9.00 x 1 1.001 / 60 x Air Sensible Area Caning Height ACH ILT Fraction 101 TOTAL HOURLY HEAT LOSS FOR ROOM 7,128 I EnergyPro 3.0 By EnergySoft User Number: 3665 Job Number: Page: 28 of 46 1 343.0 X X X x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x 0.0280 x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x 44.0 423 434.0 0.0592 44.0 1,131 34.0 0.4800 44.0 718 perimeter 55.0 44.5 2,448 Items shown with an asterisk (*) denote conduction through an interior surface to another room. Page Total: Infiltration: x x x 1 9.00 x 1 1.001 / 60 x Air Sensible Area Caning Height ACH ILT Fraction 101 TOTAL HOURLY HEAT LOSS FOR ROOM 7,128 I EnergyPro 3.0 By EnergySoft User Number: 3665 Job Number: Page: 28 of 46 1 01 E RESIDENTIAL ROOM COOLING LOAD SUMMARY Tradition Village Plan 2B 7/2/01 Project Title Date Room Name Design Indoor Dry Bulb Temperature: Design Outdoor Dry Bulb Temperature: Design Temperature Difference: Master Suite/Bedroom 2 740 F 1120F 380F Conduction Area U -Value DETD 1 Btu/hr x x x x x x x x x 55.0 = = = = 1,736 34.6 1,563 38.0 1,204 38.0 1,540 8 9 (West) (West) IA2 (West) 32) 0.545 124 0.0 2.0 1. Design Equivalent Temperature Difference (DETD) Page Total Items shown with an asterisk (*) denote conduction through an interior surface to another room. Shaded Unshaded Solar Gain Orientation Area SGF Area SGF SC Btu/hr 1 (South) 2 (South) 3 (West) 4 5 (West) (West) 6 7 (West) (West) 8 9 (West) (West) IA2 (West) 0.0 x x X x x X x X x X I :A, + + + + + + + + + 34.0 X x x X x X X X X x 32) X x x )X X X 0.545 = = = = = = = = 593 0.0 7.1 32) 0.545 124 0.0 2.0 73) 0.545 80 0.0 1 I 2.0 73 0.545 80 0.0 1 - 2.0 73 -)x - 0.545 80 0.0 161+ 5.0 73) 0.545 199 - 0.0 :�Aiii - 16.0 -)X 73 -0.545 637 0.0 32.0 73 0.545 1,274 13.0 1-6.0 -73) -0.545 637 0.0 32.0 73)x 0.54 1,274 Sched. Page Total Internal Gain Frac. Area Heat Gain Btu/hr Lights 1.00 X 1,127 x 0.000 Watts/sqft x 3.41. BtuhfWatt 0 Occupants 1.00 x 1,127 X 255 Btuh/occ. / 250 sqftlocc. 1,150 Receptacle 1.00 X 1,127 x 0.200 Watts/sqft x 3.413 BtuhfWatt 769 Process 1.00 x 1,127 X 0.000 Watts/sqft X 3.412 BtuhfWatt 0 Infiltration: X 1.064 X 1,12]7 x 10.80 x [:::�io:o] / 60] ILE a �1060 Sensible Area Celifing Height Fraction [TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 21,382 Sched. Latent Gain Frac. Area Heat Gain Btu/hr Occupants 1.00 x x 225 Btuh/occ. 1 250 sqftlocc. Receptacle 1.00 x x 0.000 Watts/sqft x 3.41� BtuhfWatt = Process 1.00 x x 0.000 Watts/sqft x 3.41 J, Btu h[Watt = Infiltration: 4,77 x X 1 10.80 x [� �1 0.003941 [Esc �e 1 Ooeo X [�,r L a �en Area C-eling eg oo /60 1 A1W Fraction FTOTAL HOURLY LATENT HEAT GAIN FOR ROOM 4,831 1EnergyPro 3.0 By EnergySoft User Number: 3665 Job Number: Page: 29 of 46 9 0 E RESIDENTIAL ROOM COOLING LOAD SUMMARY Tradition Village Plan 2B 7/2/01 Project Title Date Room Name Master Suite/Bedroom 2 D esign Indoor Dry Bulb Temperature: 740 F Design Outdoor Dry Bulb Temperature: 1120F Design Temperature Difference: 38OF Conduction Area U -Value DETID I 1. Design Equivalent Temperature Difference (DETD) Items shown with an asterisk (*) denote conduction through an interior surface to another room. S haded Unshaded Solar Gain Orientation Area SGIF Area SGIF A3 Page Total SC Btu/hr Btu/hr (West) 0.0 x x x x x x x x x x is + + + + + + + + + + 6.0 x x x x x x x x x x 73) X )x )x 0.545 239 —)x —)x —)x —)x —)x —)x —)x Sched. Page Total Internal Gain Frac. Area Heat Gain Btu/hr Lights 1.00 X 1,127 X 0.000 Watts/sqft x 3.41 BtuhfWaft 0 Occupants 1.00 x 1,127 X 255 Btuh/occ. / 250 sqftlocc. 1,150 Receptacle 1.00 X 1,127 X 0.200 Watts/sqft x 3.413 BtuhfVVaft 769 Process 1.00 x 1,127 X 0.000 Watts/sqft x 3.413 BtuhfWaft 0 J 27 x Infiltration: x 1.064 X il�� ng �iojo x [:��oo 60] . �120 "r ensible Area Fraction FTOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 21,382 Sched. Latent Gain Frac. Area Heat Gain Btu/hr Occupants 1.00 x x 225 Btuh/occ. if sqft/occ. Receptacle 1.00 x x 0.000 Watts/sqft x 3.41J, BtuhfWaft = Process 1.00 x x 0.000 Watts/sqft x 3.41 BtuhfWatt = Infiltration: x 4,77 x 1,127 X lo.8o x [::;-1� .00 IFS ;ce i.�0.0 LAFrizatent Area ening Heigh c, 60] /�M Fraction [TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 4,831 EnergyPro 3.0 By EnergySoft User Number: 3665 Job Number: Page: 30 of 46 0 0 RESIDENTIAL ROOM COOLING LOAD SUMMARY Tradition Village Plan 2B 7/2/01 Project Title Date Room Name Ent/Din/PQtfLiv/G11ry/PvAr/Ln Design Indoor Dry Bulb Temperature: 740 F Design Outdoor Dry Bulb Temperature: 1120F Design Temperature Difference: 380F Conduction R-38 Roof (R.38.2xl4.16) R-21 Wall (W.21.2x6.16) Solid Wood Door Sunair NonMtl Tinted Sunair NonMtl Tinted Area X X X X X x x x x U -Value 1,967.0 0 1,620.7 0 24.0 0 196.0 0 217.3 0 (East) 17 abv (East) 18 (East) 119 abv (East) 15) DETD' x 55.0 x 34.6 x 34.6 x 38.0 x 38.0 x x x x 1. Design Equivalent Temperature Difference (DETD) Items shown with an asterisk (*) denote conduction through an interior surface to another room. Shaded Unshaded Solar Gain Orientation Area SGIF Area SGIF 10 (North) 11 (North) 12 (North) 13 (North) 14 (East) 15 abv (East) 16 (East) 17 abv (East) 18 (East) 119 abv (East) Page Total Btu/hr 3,030 3,320 322 3,575 3,798 SC Btu/hr 0.0 x x X x x x x x x X 1 + + + + + + + + + + 34.0 X x X x x X x X X x 15) X X X ) x X )x X x 0.545 = = = = = = = = 278 0.0 1 16.0 15) 0.545 131 0.0 1 I 32.0 15) 0.545 262 0.0 i 16.0 15 0.545 131 0.0 1 16.0 73 -)x 0.545 637 0.0 1 3.0 73) 0.545 119 0.0 i 32.0 73 - 0.545 1,274 0.0 1d. 6.0 -)X 73 0.545 239 0.0 -32.0 -73) -0.545 1,274 - ITO F-6.0 73) 0.545 239 Sched. Page Total Internal Gain Frac. Area Heat Gain Btu/hr Lights 1.00 X 1,967 x 0.000 Watts/sqft x 3.413 BtuhNVaft 0 Occupants 1.00 X 1,967 X 255 Btuh/occ. / 250 sqftlocc. 2,006 Receptacle 1.00 X 1,967 x 0.200 Watts/sqft x 3.413 BtuhNVatt 1,343 Process 1.00 x 1,967 X 0.000 Watts/sqft x 3.412 BtuhfWaft 0 Infiltration: 1.064 X 1,9,]7 x [::� �ioo / 60] �c a �120 X �Alrr sensible Area X L �n� �16%98 Fractlon ITOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 42,839 Sched. Latent Gain Frac. Area Heat Gain Btu/hr Occupants 1.00 x x 225 Btuhlocc. 250 sqft/occ. Receptacle 1.00 x x 0.000 Watts/sqft x 3.41 , BtuhfWatt Process 1.00 x x 0.000 Watts/sqft x 3.41J, BtuhfWatt Infiltration: x L 4,77 x 1,96� X x 60] 0 00394 ATrTa Area Calling Height Fraction FTOTAL HOURLY LATENT HEAT GAIN FOR ROOM 8,542 I EnergyPro 3.0 By Energysoft User Number: 3665 Job Number: Page: 31 of 46 9 0 11 RESIDENTIAL ROOM COOLING LOAD SUMMARY Tradition Village Plan 2B 7/2/01 Project Title Date Room Name Design Indoor Dry Bulb Temperature: Design Outdoor Dry Bulb Temperature: Design Temperature Difference: Conduction Area U -Value x Ent1Din/KjtfLiv/G11ry/Pwdr/Ln 740 F 1120F 1. Design Equivalent Temperature Difference (DETD) Items shown with an asterisk (*) denote conduction through an interior surface to another room. Shaded Unshaded Solar Gain Orientation Area SGF Area SGIF 20 (East) 21 abv (East) 22 (East) 23 abv (East) A (East) Al (East) 26 (South) 27 (South) 239 0.0 id. 16.0 DETD' Page Total SC 380F Btu/hr Btu/hr 0.0 x x X x x x x x x X- :::1 + + + + + + + + + + 32.0 X x x X x X x x x x 73) X x x X x x Px 0.545 = = = = = = = = 1,274 0.0 11, 6.0 73) 0.545 239 0.0 id. 16.0 73) 0.545 637 0.0 1 6.0 73 -)X 0.545 239 (-0.0 1 1, 32. 0 73 -)x 0.545 1,274 0.0 32.0 73) 0.545 1,274 -34.0 - 15 -0.0 -32) -0.545 278 -0.0 -15 -62.3 -32) -0.545 1,087 -)X Sched. Page Total Internal Gain Frac. Area Heat Gain Btu/hr Lights 1.00 X 1,967 x 0.000 Watts/sqft x 3.413 BtuhNVatt 0 Occupants 1.00 X 1,967 X 255 Btuh/occ. / 250 sqftlocc. 2,006 Receptacle 1.00 X 1,967 x 0.200 Watts/sqft x 3.413 BtuhNVatt 1,343 Process 1.00 x 1,967 X 0.000 Watts/sqft x 3.413 BtuhfWatt 0 Infiltration: x 1064 X x J,� I ng �1%98 xE:� too 60 Lc . �120 INFr Sensilble Area c Fraction ITOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 42,8391 Sched. Latent Gain Frac. Area Heat Gain Btu/hr Occupants 1.00 x x 225 Btuh/occ. 250 sqft/occ. Receptacle 1.00 x x 0.000 Watts/sqft x 3.411 BtuhfWatt = Process 1.00 x x 0.000 Watts/sqft x 3.41J, BtuhfWatt = Infiltration: x 4,77 X 1,96� X too / 60] x E:�� LA . en� Area Celling Reight c z!1W Fraction [TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 8,542 IEnergyPro 3.0 By EnergySoft User Number: 3665 Job Number: Page: 32 of 46 1 RESIDENTIAL ROOM COOLING LOAD SUMMARY Tradition Villacie Plan 213 7/2/01 Room Name Design Indoor Dry Bulb Temperature: Design Outdoor Dry Bulb Temperature: Design Temperature Difference: Conduction R-38 Roof (R.38.U114.116) R-21 Wall (W.21.2x6.16) Surtair NonMtl Tinted Area U -Value x 1. Design Equivalent Temperature Difference (DETD) Items shown with an asterisk (*) denote conduction through an interior surface to another room. Shaded Unshaded Solar Gain Orientation Area SGF Area SGF 28 Guest Suite 740 F 1120F DETD 1 55.0 34.6 38.0 Page Total �L* 380F Btu/hr 528 889 620 Btu/hr (East) 0.0 x X x x x x x x x x 15 + + + + + + + + + + 34.0 X x x x x X x x x x 73) X x x ) x ) x 0.545 1,354 -)x -)x - -)x -)x -)x Sched. Page Total Internal Gain Frac. Area Heat Gain Btu/hr Lights 1.00 X 343 X 0.000 Watts/sqft x 3.413 BtuhfWatt 0 Occupants 1.00 X 343 X 255 Btuh/occ. / 250 sqftlocc. 350 Receptacle 1.00 X 343 X 0.200 Watts/sqft x 3.413 BtuhfWatt 234 Process 1.00 x 343 x 0.000 Watts/sqft x 3.412 BtuhfWaft 0 Infiltration: x 1 x 343� X 9.00 xE;-1,�oo Lc;e 10�60 Air Sensibie Wirea C -e -fling Height c, 60] Fraction ITOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 6,056 Sched. Latent Gain Frac. Area Heat Gain Btu/hr Occupants 100 x x 225 Btuh/occ. 250 sq 309 Receptacle 1.00 x x 0.000 Watts/sqft x 3.41 B u=tt t 0 0 Process 1.00 x x 0.000 Watts/sqft x 3.411�, Btuh[Watt Infiltration: x I x x I g.00l x [:��j.00 I / 6 Airl-atent Area tening meignt H 01 lonlw Fraction [TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 1,277 lEnergyPro 3.0 By EnergySoft User Number: 3665 Job Number: Page: 33 of 46 1 0 GASFUR;A'CES C340U H ENGINEERING DATA MERIT 80' SERIES Up-Flow/Horizontal AFUE - 80.0% Input - 44,000 to 110,000 Btuh (12.9 to 32.2 kW) Add-on Cooling - 1 to 4 Tons (3.5 to 14.1 kW) Bulletin No. 210278 June 2000 UP -FLOW POSITION A i _097 allt. 01(( Typical Applications Closet Installation With cooling coil Unit Type G - Gas Furnace Series 40 - Merit 80% Configuration UH - Up-Flow/Horizontal 02 G40UH -: HORIZONTAL POSITION Attic Installation With cooling coil and electronic air cleaner 1,- 045X Low NO, - Units meet California Nitrogen Oxides standards Nominal Gas Heat -Input 045 - 44,000 Btuh (12.9 kW) 070 - 66,000 Btuh (19.3 kW) 090 - 88,000 Btuh (25.8 kW) ElCabinet Width 1107 110,000 Btuh (32.2 kW) A - 14-1/2 in. (363 mm) B - 17-1/2 in. (445 mm) C - 21 in. (533 mm) CoilS with the same letter designation will physically match the furnace. Nominal Add -On Cooling Capacity 24 - 2 tons (7.0 kW) 36 - 3 tons (10.6 kW) 48 - 4 tons (14.1 IkW) NOTE - Due to Lennox' ongoing committment to quality. Specifications, Ratings and Dimensions subject to change without notice and without incurring liability. Improper installation, adjustment. alteration. service or maintenance can cause property damage or personal injury. Installation and service must be performed by a qualified installer and servicing agency. 02000 Lennox Industries Inc. Sent By: LENNOX IND INC; 909 590 9897; Apr -17-01 9:31AM; Page 5 0 I-] L 1 M -A I E-4 I kltz� Me" "a. GWUW2","S GOUH4W490 GOUH41154M MOdL4 No. - -X" Modek, 7 G4Kft-M-04= G40UH.36A.U= ---- G40U4A3&GM - Btuh (kWj 0 44.000 (12.3) 66.000 (19.3F- 88.000 (25.8) W=Input Put81Bvuh (kW) 36.011) (10.5) 54,100 (15.6) 72.100(21.1) AAFUE 80.0% COA)nlia SeAsunal Emciericy 74.2% 74.8% 1 7 75.3% Hlgh static (AC.NCGA) - in: w.g. (Pa) .50(124) Flue ocinriection - in. (mm) round 4(102) Gas pipe size IPS - in. (mm) 1/2(12.7) To-perature rize range - -r- (-c) 35-66 (19 - 36) 40 - 70 (22 - 39) Slower wheal nom. diameter & width - in. (mm) 10 x 7 (254 x 17B) 10 x 8 (254 x 203) 10 x 10 (21� x 254) Siowvir nxg- output - hp (W) 1/6(149) 1/3(249) 112(373) Tons (W of add-on 000ling 1 - 2 (3.5-7.0) 1 - 3 (3.5 - 10.6) 2 - 4 (7.0 -14.1) Shipping weignt - lbs. (kg) I p.�ckaga 121(55) 1 132(60) .1 146(86) 153(69) Flec.�l characle.1stics 120 -It& - So haft - I phass (less thari 12 amps) TMatching C33 �up-flow cased) I H33 (honzontal) Colls C33-iaA-2F, C33 -24A -2F, C33-3 2F, C33-36A-2F� c-p-wA-21F, CH33-18A-2F, U-W-24MA-21c, CH33-36A,2F C33-249-217. C3141CS-21F, C33,�. C33 -U!8 -21F, CM42B-212, CM48EI-21F, CH3a-368-2F, CH33A28-2f� CH33-"A8&ZF W 1lx M Air Filter and Rack K11 NO. and size offilters- imtrrim) HorLaorilal (end) 87L95-(1)14x25x1(358x635x25) I ff7L9G-(1)18x25x1(A57x6 X25) ISideRetism Single 44J22 or Ten Pack (66K63) - (j) 16 x 25 x 1 (406 x 635 x 251 EZ Filter Base 1 Catalog Number - Shipping WL - lbs. (kg) 73P56 - 6 (3) 73P56 - 7 (3) j0irnen3iorts-HxWxD-in.(mm) ____._.4xl�6,1/4x2f�-5/8(102x362x?27) No. & size of -filter (Wd provided) - in. (rnm) 4 x 17-&8 x 28-5/8 (102 x 448 x 727) x , x x 635 x 25) 16 x 25 x 1 (406 x 635 x 25) ,:Zj High AlUtude Pressm Swft& IQ 561.32 49U0 Hon;=nal Support Frarne Ks - ShWV W*ft - lbs. (14) SWiS - 18 lbs. (8 kg) LPG/Propane KIt 45LGO Twinning Kit ISL38 FkM UMMW MWICY T UOE Ma ptoosoom &V woormig lo F I C MMV regAzorm. Wow conrumori sysm MV kr rm-%� UMKW. NOTE - Filtem and orovisms for matintivig am not fumlsttW and mu2t be fleki pmvkie& M -,he sams C33 uncased motWs match the furnaces WuNm ban mquim an opawAW adaptor base or field fabrr-stad tranamn. Sae C33 coil Willow for aciditmal rftm;;*W. I ,09-equinWforproporopore6ov ataKftxje9ww4,5Wtc.(13Mm). r3l Clismable poNumthane frome Mm fftr A *Anmmi Ftx4 Utiltrabon Efterky. basW on DOE am promdim 9W accordiM 13 IFTC. nla� Woloatti coffbaum Syst= rAro for nWwW&MUed Lffacm NO T7E - Fi4tem and provissom for mountrig am not furnished arid rr%ct be FAdd pruyided. M The serne C33 urcarAd modeW me" tho lurrvaca* shwn but r"qufft an Optional adapW bat* or fWU t8brICAW b-ansidon. Sw C33 oa bulletin for addMonai Inliormadon. -M Required for wooer operaiion at anftde& oer 4= ft. (1370 rn). Q] ClWigble potyurutlione rrartso type ft4a. fZ1 PAbe corriewmen an ft unit Is 4 In. (102 rrvn) damew. Moot applicaftm will motAe 5 h (127 mm) ventriq ard fitild avpftd 4 x Sh (IM x 177 mm) xWow. See V&" TaMea n tn Irticallaim kwoucliartt; ior do%" h1offnaim jM No for �ae -1h RAa Amu. Ae Qew or wAs 60C And am sam ur%ft wo air ftw re*ummetim of i aoO ctm, (M Lja� or Wemr So$ Pjo%w Pwb. ws TOAM fm wkibmial G4OUH I Page 4 10. or SPECIFICATION�S GAMM41M-1110 GAGUHMr-135,1 GAI&A"MC-114 Gilak"W436 GdOL44-SOD-156 Input - Stith (kw) tU.z 71u,UWW-.i0 132,000(38.7) cutput - Stun (kW) IGB.9W (31.3) IJU,2UU (W.4) 1U6.901)(31.3) *AFUE 30.0% CalifDmie Seascinat Efficiemy 75.7% 76.0% 15.1% 76.0% High static (AGAIGGA) - in. w.g. (PaT- .50 (124) Flue ocinnection : in. (mm) round 4(102) M4 (102) 4(1021 M4 (102) Gas pipe size ips - 15'. (MM) Ternpairatire rise range - -F (-C) 40 - 70 (22 (28 50 - 80 �28 - 35 - 65 (19 - 38) 45 - 75 (25 - 42) 1 M - 80 Unver wrieei FOR aia. Z wtoth - tn. (trim) IU X 1U (254 X Z54) 11-1/Z x lu l;zuz x ZZ4) Blower fflotor output - hp (W) 112(373) 314 (5W) Tons (kVV) of sdo-on cooAng 2 - 4 (7.r- 14.1) 5 - 5+ (117.6 - 17.6+1 ShippIng weight -T5Z-(Wg-) 1 package 169(77) -T t78 (81) 172(78) 1 7� --201 (91)-- Ekwbical characi rT--acs i -20 voft ertz - 1 prtasa (loss than 12 amps) W Match Lng G33 ( p-Aow casod) CH33 (horizontal) Coils U C3136C-21F. C33 -MIC -21F. MMOMOC-21F, C1433,2[6C-21c, CH33-48C-2F, CH33-5OtW-2F -60M9F' C33 -620-2r I CH33-6150-2F� CJA33-620-2F C31 . ... .. .. . . ......... M Ak, RW mid RS& Kil Hon=fwd (eM) M97 - (1) 20 x 25 x I (SOF x 635 x 251 STL M (112 5 . 2 5 x Number and size of W"s - in. (mm) I Side Rewrn MSingW-43ff-or TeRn Fwk (GGK53) - (1) 16 x 25 x 1 (400 x M5 x 26) Log NuMber - Srdpplr#g WL - Ze. (Kg) 731597 - 8 (4) T- 73PSO - 10 (5) EZ f9fter Cimensions - H x W x 0 - in. (mm) Sase A x V-518 x 28-5/8 14 x 24-&8 x 28.&8 (102 x 625 x R7) No. & stre of fifter (W 56NRa) - F. FMM7 20 x Z-X-rp=x W35 x2b) 1 24 x 24 x 1 (510 X 810 X 25) -if High Altilaxie, Pressure Switch KA 4SL90 Horcocritel Support Favirie Kit - Stvp. VYL - bm ft) Sul a - 18 bs. (8 kg) PLAU Return Air Gase .... I RAB60C (12M71)l PMWP (TMWTY)- LPC-.7Prcparie kW I _1 v^nning KIT *Anmmi Ftx4 Utiltrabon Efterky. basW on DOE am promdim 9W accordiM 13 IFTC. nla� Woloatti coffbaum Syst= rAro for nWwW&MUed Lffacm NO T7E - Fi4tem and provissom for mountrig am not furnished arid rr%ct be FAdd pruyided. M The serne C33 urcarAd modeW me" tho lurrvaca* shwn but r"qufft an Optional adapW bat* or fWU t8brICAW b-ansidon. Sw C33 oa bulletin for addMonai Inliormadon. -M Required for wooer operaiion at anftde& oer 4= ft. (1370 rn). Q] ClWigble potyurutlione rrartso type ft4a. fZ1 PAbe corriewmen an ft unit Is 4 In. (102 rrvn) damew. Moot applicaftm will motAe 5 h (127 mm) ventriq ard fitild avpftd 4 x Sh (IM x 177 mm) xWow. See V&" TaMea n tn Irticallaim kwoucliartt; ior do%" h1offnaim jM No for �ae -1h RAa Amu. Ae Qew or wAs 60C And am sam ur%ft wo air ftw re*ummetim of i aoO ctm, (M Lja� or Wemr So$ Pjo%w Pwb. ws TOAM fm wkibmial G4OUH I Page 4 10. or