BRES2015-010878-495 CALLETAIV!151to�
LA QUINT-A,'CA"L'I'F'O'iRNIA-922.53�',
Application Number:
Property Address:
APN:
Application Description
Property Zoning:
Application Valuation:
Applicant:
STRACTSINC
550 S. OLEANDER ROAD
PALM SPRINGS, CA 92264
4
.COMMUNITY, DEVELOPMENT DEPARTMENT
BUILDING PERMIT
BRES2015-0108
78234 PINNACLE POINT"�
770370043
HOSTETTER/SITTING ROOM
$40,000.00
JUN 5 2015
CRY
LICENSED CONTRACTOR'S DECLARATION
I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter
9 (commencing with Section 7000) of Division 3 of the Business and Professions Code,
and my License is in full force and effect.
License Class: B icense No.: 346196
C4 (tr/actor:����
(Date: OWNER-BUI DER DECLARATION
I hereby affirm under penalty of perjury that I am exempt from t //eC6Ma`ctor's State
License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any,
city or county that requires a permit to construct, alter, improve, demolish, or repair
any structure, prior to its issuance, also requires the applicant for the. permit to file a
signed statement that he or she is licensed pursuant to the provisions of the
Contractor's State License Law (Chapter 9 (c6mmencing with Section 7000) of Division 3
of the Business and Professions Code) or that he or she is exempt therefrom and the
basis for the alleged exemption. Any violation of Section 7b3l. 5 by any applicant for a.
.permit subjects the applicant to a civil penalty of hot more than five hundred dollars
($500).: e
( ) 1, as owner of the property, or my employees with wages as their sole
compensation, will do the work, and the structure is not intended. or offered for sale.
(Sec. 7044, Business and Professions Code: The Contractors' State License Law does not
apply to an owner of property who builds orimproves thereon, and who does the work
himself or herself through his or her own employees, provided that the imorovements
are not intended or offered for sale. If, however, the building or improvement is sold
within one year of completion, the owner -builder will have the burden of proving that
he or she did not build or improve for the purpose of sale.).
1, as owner of the property, am exclusively contracting with licensed contractors
to construct the project. (Sec. 7044, Business and Professions Code: The Contractors'
State License Law does not apply to an owner of property who builds or improves
thereon, and who contracts for the projects with a contractor(s) licensed pursuant to
the Contractors' State License Law.).
I am exempt under Sec. _ B.&P.C. for this reason
Date:
Owner:
CONSTRUCTION LENDING AGENCY
I hereby affirm under penalty of perjury that there is a construction lending agency for
the performance of the work for which this permit is issued (Sec. 3097, Civ. C.).
Lender's Name:
. J
Lender's Address:
VOICE (760) 777-7125
FAX (760) 777-7011
INSPECTIONS (160) 777-7153
Date: 6/5/2015
Owner:
JERRY HOSTETTER -
121 ESHELMAN RD
LANC�STER, PA 92253
Contractor:
KELLY DOMER PARTNERS INC DBA K
1554 LINCOLN AVE
SAN RAFAEL, CA 94901
(415)464-0900
LIc. No.: 346196
WORKER'S COMPENSATION DECLARATION
I hereby affirm under penalty of perjury one of the following declarations:
I have and will maintain a certificate of consent to self -insure for workers'
compensation, as provided for by.Section 3700 of the Labor Code, for the performance
of the work for which this permit is issued.
I have andwill maintain workers' compensation insurance, as required by
Section 3700 of the Labor Code, for the performance of the work for which this permit
is issued. - My Workers' compensation insurance carrier and policy number are:
Cartier: Policy Number:
I that in the performance of the work for which this permit is issued, I
shall not employ any p . erson in any manner so as'to become subject to the workers'
compensation laws of California, and agree that, if I should become subject to the
workers; co�npensation provisions of Section /3700of t Labor Code, I shall forthwith
complywiththose dvisions.
/P
t
Dade Ari DIlican
WARNING: FAILURE iO SECURE WWR—. S' COMPENSATION COVERAG NLAWFUL,
' V'c
AND SHALL SUBJECT AN ' EMPLOYv 0 CRIMINAL PENALTIES AND CIVfL FINES UP TO
ONE HUNDRED THOUSAND 1)012i�RS ($100,000). IN ADDITION TO THE COST OF
COMPENSATION, DAMAGESAS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE,
INTEREST, AND ATTORNEY'S FEES.
APPLICANT ACKNOWLEDGEMENT
IMPORTANT: Application is hereby made to the Building Official for a permit subject to
the conditions and restrictions set forth on this application.
1.� Each person upon whose behalf thig application is made, each person at whose
request and for whose benefit wc�rk is performed under or pursuant to any permit
issued as i'result'ofthis application , the owner, and the applicant, each agrees to, and
shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents, and
employees for any act or omission related to the work being performed under or
following issuance of this permit.
2. Any permit issued as a result'of this application becomes null and void if work is
not corrimericedwithin 1 * 80 days from date of issuance of such permit, or cessation of
work for 180 days will subject permit to cancellation.
I certify.that I have read this application and state that the above information is correct.
I agree to comply with all city and county ordinances and state laws relating o bouildin
0
f t V
construction;'and hereby authorize representatives of this toe u th e.
mentioned prorlerty for inspection purposes.
PPI
irh Sgnature (Ap Ii
Date: 11' n
FINANCIAL INFORMATION
DESCRIPTION
ACCOUNT
QTY
AMOUNT
PAID
PAID DATE
ADDITION, EA ADDITIONAL 500 SF
101-0000-42400
0'
$62.36
$62.36
6/5/15
PAID BY
METHOD
RECEIPT,#
CHECK #
CLTD BY
KELLY PACIFIC CONSTRUCTION
CHECK
R6832
14625
MFA
DESCRIPTION
ACCOUNT
CITY.
AMOUNT
PAID
PAID DATE
ADDITION, EA ADDITIONAL 500 SF PC
101-0000-42600
0
$17 .40
$17.40
6/Sj1S
PAID. BY
METHOD
RECEIPT #
CHECK #
CLTD BY
KELLY PACIFIC CONSTRUCTION
CHECK
R6832
14625
MFA
D.ESCRIPTION
ACCOUNT.
QTY
AMOUNT
PAID
PAID DATE
ADDITION, FIRST 100 SF
101-0000-42400
0
$120.83
$120.83
6/5/15
PAID BY
METHOD
RECEIPT #
CHECK #
CLTD BY
KELLY PACIFIC CONSTRUCTION
CHECK
R6832
.14625
MFA
DESCRIPTION
ACCOUNT
CITY.
AMOUNT.
PAID.
PAID DATE
ADDITION, FIRST 100 SF PC
101-0000-42600
0
$171.14
$171.14
6/5/15
PAIDIBY
METHOD
RECEIPT #
CHECK #
CLTD BY
KELLY PACIFIC CONSTRUCTION
CHECK
R6832
14625
MFA
Total Paid forADDITION: $371.73 $371.73
DESCRIPTION
ACCOUNT
QTY'
AMOUNT
PAID
PAID,DATE:
BSAS S81473 FEE
101-0000-20306
0
$2.00
$2.00
6/5/15
PAID BY
METHOD
RECEIPT #
CHECK #
CLTD BY
KELLY PACIFIC CONSTRUCTION
CHECK
R6832
14625
MFA
Total Paid forBUILDING STANDARDS ADMINISTRATION BSA $2.00 $2.00
DESCRIPTION
ACCOUNT
iQTY
AMOUNT
PAID
PAID DATE
RESIDENTIAL, FIRST 1,OOOSF
101-0000-42403
0
$145.03
$145.03
6/5/15
PAID BY
METHOD
RECEIPT #
CHECK #
CLM By
KELLY PACIFIC CONSTRUCTION
CHECK
R6832
14625
MFA
DESCRIPTION
ACCOUNT
QTY
AMOUNT
PAID
PAID DATE
RESIDENTIAL, FIRST 1,OOOSF, PC
101-0000-42600
0
$47.86
$47.86
6/5/15
PAID BY
METHOD
RECEIPT #
CHECK #
CLTD BY
KELLY PACIFIC CONSTRUCTION
CHECK
R6832
14625
MFA
Total Paid forELECTRICAL - NEW CONSTRUCTION: $192.89 $192.89
DESCRIPTION
ACCOUNT
QTY:
AIVIOUNT.
PAID
PAID DATE
FURNACE
101-0000-42402
0
$36.26
$36.26
6/5/15
PAID BY
METHOD
RECEIPT #
CHECK #
CLTD BY
KELLY PACIFIC CONSTRUCTION
CHECK
R6832
14625
MFA
DESCRIPTION
ACCOUNT
QTY.
AMOUNT
PAID
PAID DATE
FURNACEPC
101-0000-42600
0
$24.17
$24017
6/5/15
PAID BY
METHOD
RECEIPT #
CHECK #
CLTD BY
KELLY PACIFIC CONSTRUCTION
CHECK
k6832
14625
MFA
Total Paid forMECHANICAL: $60.43 $60.43
Won
Oh"'�P:� t 9`66'- 2 0 3-' $5;20 6/5/15
SMI - RESI ENT 5.20..
-�HECK "R6832 14625 MFA
KELLY PACIFIC CONSTRUC71710�
2111-
-`$5.20
Description: HOSTETTER/SITTING ROOM ADDITION
Type: BUILDING RESIDENTIAL
Subtype: REMODEL Status: ISSUED
Applied: 3/26/2015 ECON
WEB
CHRONOLOGY
Approved: 6/1/2015 AOR
Parcel No: 770370043 Site Address: 78234 PINNACLE POINT LA QUINTACA 92253
Subdivision: TR 30056
Block: Lot: 4
Issued: 6/5/2015 MFA
Lot Scl Ft: 0
Building Scl Ft: 0 Zoning:
Finaled:
Valuation: $40,000.00
Occupancy Type: Construction Type:
Expired: 12/2/2015 MFA
No. Buildings: 0
No. Stories: 0 No. Unites: 0
4/16/201S
Details: 212SF SITTING ROOM ADDITION TO EXISTING BEDROOM 2/VB/RES-3/CLASS A-FR/NON-SPRINKLERED. 2013 CALIFORNIA BUILDING
CODES
67
4
__j Applied to Approved
IM;Approved to Issued
Printed: Friday, June 05, 2015 3:00:13 PM I of 5 CRWYSTEMS
ADDITIONAL SITES
CHRONOLOGY
CHRONOLOGY TYPE",'
.��STAFF N A M_ _E-��', ".7
---'4 b4fE -COMPLETION:
CT ON, DATE�-'f`
SENT CORRECTION- LIST PDF TO ANTON PER HIS REQUEST AS
E-MAIL
BURTHANADA
4/16/2015
4/16/201S
HE HAD NOT BEEN CONTACTED BY A.Z. FOR STEPS TO
RETREIVE COMMENTS, IN EMARKUP.
ANGELICA,
NOTE
ANGELICA ZARCO
4/16/2015
S/S/201S
I SENT ANTON FROM STRACTS THE CORRECTION LIST VIA
EMAIL AS HE SAID HE HADN'T BEEN CONTACTED ON HOW TO
RETREIVE HIS COMMENTS IN EMARKUP.
PLAN CHECK
REDLINED PLANS PUBLISHED AND COMPLETE CORRECTIONS
COMPLETE/READY FOR PICK
AJ ORTEGA
4/13/2015
4/14/2015
LIST UPLOADED - PROJECT FORWARDED TO AZARCO FOR
UP
CONTACT WITH APPLICANT AND ETRAKIT RETRIEVAL.
PHONED ANTON MARINKOVICH, LEFT MESSAGE THAT PLANS
TELEPHONE CALL
AJ ORTEGA
6/1/201S
6/1/201S
ARE APPROVED AND READY TO ISSUE WITH SCHOOL FEE
EXEMPTION AND VALID CONTRACTOR.
CONDITIONS
Printed: Friday, June 05, 2015 3:00:13 PM I of 5 CRWYSTEMS
I.— gmg
VIC
I i - H
NO
w
MA
I E N
&TAT111
01
ON
1- MOM
0.9- 1 1 1 i i I I&E, IT V M%V
-REMAR
ON
X;i
UP
Ri
m
w
m
R. 'T HOOL
READY TO ISSUE
_ATORTEGA...
6/1/2015
INc6m�LET14"'
1101-dadb�424bo
0�:.'., �___$62.36 $62.' -36
--',6/SZ1S- -.116832�'j
1462S:,. �CHECK
ktd-IFIC�:
0 `A�
-.MFA
FEE EXEMPT[ ON.-:
im v!
OEM M
-fie
'Naft-1010 FIN I I
It w
AP AeTSINC''
i �.�OL Wiff OAD
SSO"z
"PALM SP
aRt6h stracts.com
0' KELLY:DOM R P b""
NTRACTOR "AlkA-E-Ri.-M- BAK
4 LIN'COLWAVt
SA`N_,RAFAhL
94901,
--.--.OWNER,,- ..JERR I Y HOST !T7
2i. h6
I ESHE
KELLY PAClk'��
',CONS.T
j _0A jii T7,
-ADDITIONAL 506,SF.PC
'0
X;i
VIM. ill
'A'
IN 20 L L 0 U N T&I
w
m
sm"Otm
1101-dadb�424bo
0�:.'., �___$62.36 $62.' -36
--',6/SZ1S- -.116832�'j
1462S:,. �CHECK
ktd-IFIC�:
0 `A�
-.MFA
ADDITRNAL51010,5F
N 710!
CO STRUC
Abi iii6N-iA-*..
101� 000-42600
$1�.4 b'
.-6 SJIS R6832_.,
4
'1 625,
KELLY PAClk'��
',CONS.T
MFA
-ADDITIONAL 506,SF.PC
'0
ADDITION. -FIRST 100 SF.
`0
.101, -000-:424'dQ
.0 $120'.,83 $A2b;93.
-6 5 1S, '"R68j2
1462S:. CHECK
KELLY_PA IFI
�CONSTRUqlpliil
ADDITION, FIRST 100 SF-
101m=0742600
6 $i7i.14 ..$171' .14L
6/S 15 116831-
14 62S, -CHECK.
1E LIV44CIOIC
MFA
P
CONSTRUCTION
-
6id'forADDITI �371.7.i 71.73
BSAS SB1473 FEE
101-0000-20306
0
$2.60
$2.00
F6/5/is
R6832
146iS
CHECK'
KELILV P4,66C -
MFA�
.
-.CON!
Total Paid for BUILDING STANDARDS ADMINISTRATION
$1.00 p.00
6SA:
RESIDENTIAL, FIRST
.101-0000-42403
0
$14S.0j
$145.03
6/S/1S
R6832
1462S
CHECK
KELLY PACIFIC
MFA
1,000SF
CONSTRUCTION
RESIDENTIAL, FIRST
101-0000-42600
0
$47.96
$47.86
6/S/iS
R6832
CHECK
KELLY PACIFIC
MFA
1,000S�, PC..
.1462S
CONSTRUCTION
Total Paid for ELECTRICAL - NEW CONSTRUCTION: $192.89- $192.80
P ri. nted:' Friday, June 05, 2015 3:00:13 PM 2 of 5 C§?W.,YsTrms
Printed: Friday, June 05, 2015 3:00:13 PM 3 of 5 e7pw.'YSTEMS
SEQID INSPECTION TYPE INSPECTOR SCHEDULED COMPLETED
DATE DATE
RESULT REMARKS NOTES
FINAL"
REVIEWS
CLTD
DESCRIPTION
ACCOUNT
QTY
AMOUNT
PAID
PAID DATE
RECEIPT#
H CK#
METHOD
PAID BY
YOUNG
ENGINEERING
3/27/2015
4/10/201S
4/13/2015
REVISIONS REQUIRED
PROVIDE FRAMING DETAIL - NEW TO EXISTING.
SHOW ATTACHMENT OF NEW PARAPET
PROVIDE FRAMING DETAIL - NEW TO EXISTING
PROVIDE FRAMING DETAIL - NEW TO EXISTING
SHOW ATTACHMENT OF PARAPET
NOT A CONTINOUS FOOTING DETAIL
BY
FURNACE
101-0000-42402
0
$36.26
$36.26
6/5/15
R6832
14625
CHECK
KELLY PACIFIC
MFA
CONSTRUCTION
FURNACEPC
101-0000-42600
0
$24.17
$24.17
'6/5/15
R6832
14625
CHECK
KELLY PACIFIC
MFA
I
I
I
I
I CONSTRUCTION
Total Paid forMECHANICAL: $60.43 $60.43
SMI - RESIDENTIAL
101-0000-2030
$5.20
$5.20
6/5/15
R6832
14625
CHECK
KELLY PACIFIC
I
MFA
CONSTRUCTION
Total Paid forSTRONG MOTION INSTRUMENTATION SMI: $5.20 $5.20
TOTALS: $632.25 $632.25
Printed: Friday, June 05, 2015 3:00:13 PM 3 of 5 e7pw.'YSTEMS
SEQID INSPECTION TYPE INSPECTOR SCHEDULED COMPLETED
DATE DATE
RESULT REMARKS NOTES
FINAL"
Printed: Friday, June 05, 2015 3:00:13 PM 3 of 5 e7pw.'YSTEMS
PARENT PROJECTS
REVIEWS
REVIEW TYPE
REVIEWER
SENT DATE
DUE DATE
RETURNED
DATE
STATUS
REMARKS
NOTES
STRUCTURAL
YOUNG
ENGINEERING
3/27/2015
4/10/201S
4/13/2015
REVISIONS REQUIRED
PROVIDE FRAMING DETAIL - NEW TO EXISTING.
SHOW ATTACHMENT OF NEW PARAPET
PROVIDE FRAMING DETAIL - NEW TO EXISTING
PROVIDE FRAMING DETAIL - NEW TO EXISTING
SHOW ATTACHMENT OF PARAPET
NOT A CONTINOUS FOOTING DETAIL
PROVIDE HOLDOWN PER CALC /n
NON-STRUCTURAL
AJ ORTEGA
3/27/2015
4/10/201S
4/9/201S
REVISIONS REQUIRED
NOTE #01: SHOW TEMPERED GLAZING
LOCATIONS ON PLAN
Printed: Friday, June 05, 2015 3:00:13 PM 3 of 5 e7pw.'YSTEMS
Printed: Friday, June 05,*2015 3:00:13 PM 4of5
. . CRWYSTEMS
-BRES2015'-011l !T
1ST SUBMITTAL ENERGY
DO'C -3/31/2015
AJ ORTEGA CALCULATIONS
SUBMITT �ll ENERGY 0
NOTi`h!:,SH,6lIllI1�_40ci PROTECTION AND
(REdISTEREDI)
CALCULATIONS.
TAMP ER-kESCSTANT.TYPE.AT RECEPTACLES.
T
(REqIS.ERED).pdf
BRES201S-0108 1ST
T PICAL)
Y.
1ST SUBMITTAL ENERGY
AJ ORTEGA
NOTE #03: SHOW , OPERABLE EMERGENCY ESCAPE
CALCULATIONS
CALCULATIONS. pdf
DOC 3/31/2015
AJ ORTEGA 1ST SUBMITTAL -PLAN 1
BAES2015-0108 1ST
1 .. . I .. 0
A"i"CUt-IjOENINGTROM EXISTING
ES
SU6 MITTAL PLAN.pdf
BEbRO6M 2..
ERENCE
�R.TE404. UP[ S
NON-STRUCTURAL .:AJ ORTEGA . 3/27/ift_ 4/ill/2 61S
4/9/2'01S REVIS�1116 NS REQUIRED
'NOTE
GENERAL SECTIqNS..
NOTE #0S:*SHOW:dMl -FINISH GRADE,.
AND SPECIFY.PLATE REQUIREMENTS.�.
t P R 0-V Ib; E '. E N G I AND
I) T ILINtll RAPETS.'%
-REVIEW-CORRECTION"d!�,.Is mEb—,
T T .4TT IN-
ppTPNjT9, ff3 #9V9 ?.LAN,`,CPMMENTS.
N6N-'Stk &Ull AJ'_j-"` A*i
'6 VED.
"'11/j27ill
hd
SENT.
STRUCTURAL' -
F
-READ PROVAll
E III INEEI
. ....... .... ..
I&AIIII 111�1:l A i;li
Printed: Friday, June 05,*2015 3:00:13 PM 4of5
. . CRWYSTEMS
-BRES2015'-011l !T
1ST SUBMITTAL ENERGY
DO'C -3/31/2015
AJ ORTEGA CALCULATIONS
SUBMITT �ll ENERGY 0
(REdISTEREDI)
CALCULATIONS.
T
(REqIS.ERED).pdf
BRES201S-0108 1ST
DOC 3/31/2015
1ST SUBMITTAL ENERGY
AJ ORTEGA
SUBMITTAL.ElEll 0
CALCULATIONS
CALCULATIONS. pdf
DOC 3/31/2015
AJ ORTEGA 1ST SUBMITTAL -PLAN 1
BAES2015-0108 1ST
1 .. . I .. 0
SU6 MITTAL PLAN.pdf
Printed: Friday, June 05,*2015 3:00:13 PM 4of5
. . CRWYSTEMS
Printed: Friday, June 05, 2015 3:00:13 PM 5 of 5
CRFWIYSTCAiS
Bin #
City of La Quinta
Builyipg §� Safety Division
P.O. Box 1504�78-495 Calle Tampico
La Quinta, CA 92253 - (760) 777-7012
Building Permit Application and Tracking Sheet
Permit #
Project Address:
Owner's Name
A. P. Number:
Address: 7_90S41
Legal Description: �"Or3 Fasop�,,U &7Z
City, ST, Zip: . C04-1
Contractor:
Telephone:
Address:
ProjectPescription:
City ST, Zip:
Telephone:
.. ........
Stat lic. # City Lic. #..-
Arch., Engf., Designer:
Address: 1Jr__
City, ST, Zip:
Telephone: Al- 9
......
. ....... .
.............
.....
Constructio'n T�pe: 71:�� Occupancy:X
StateLic.#:
Project type (circle one): New (jdq Alter Repair Demo
Name of Contact Persqn:,4—A/7V^1 /_fPJZ, //,!�W
Sq., Fu Z1515�r_
I # Stori es
Units:
Telephone # of Contact Person:
Estimated Value of Project: Oqv
APPLICANT: DO NOT WRITE BELOW THIS LINE
N
Submittal
Reqld
Rec1d
TRACKING
PERMIT FEES
Plan Sets
Plan Check submitted
Item'
Amount
Structural CaIcs.
Reviewed, ready for corrections
Plan Check Deposit
Truss Calcs.
.-Called Contact Person
Plan Check Balance
Title 24 Calcs.
Plans picked up
Construction
Flood plain plan
Plans resubmitted
Mechanical
-Grading plan
2". Review, ready for corrections/issue
Electric I
a
Subcontactor Li st
Called Contact Person
Plumbing
Gran(Deed
Plans picked up
S.M.L
H.O.A. Approval
Plans resubmitted
Grading
IN HOUSE:-
Review, ready for corrections/issue
Developer Impact Fee
Planning Approval
Called Contact Person
A.I.P.
Pub. Wks. Appr
Date of permit issue
School Fees
Total Permit Fees
CERTIFICATE OF COMPLIANCE
Desert Sands Unified School District
0
47950 Dune Palms Road BE MU 0 LINES
V) RANCHOMIRAGE
Date 614/15 La Quinta, CA 92253 INDIAN WELLS
PALM DESERT
LAQUINTA
No. 31817 (760) 771-8515 �QINDIO
I , 0 ��
Owner Hostetter APN # 770-370-043
Address 78234 Pinnacle Point Jurisdiction La Quinta
city La Quinta Zip Permit #
Tract # No. of Units
Type Residential Addition
Lot # No. Street S.F. Lot # No. Street S.F.
Unit 1 78234 Pinnacle Point
Unit 2
Unit 3
Unit 4
Unit 5
Comments
212 Unit 6
Unit 7
Unit 8
Unit 9
Unit 10
At the present time, the Desert Sands Unified School District does not collect fees on garages/carports, covered patios/walkways, residential additions under
500 square feet, detached accessory structures (spaces that do not contain facilities for living, sleeping, cooking, eating or sanitation) or replacement mobile
homes. It has been determined that the above-named owner is exempt from paying school fees at this time due to the following reason:
Residential Addition 500 Sq Feet or Less
EXEMPT
This certifies that school facility fqes imposed pursuant to
Education Code Section 17620 and Government Code 65995 Et Seq.
in the amount of $0.00 X 212 S.F. or $0.00 have been paid for the property listed above and that
building permits and/or Certificates of Occupancy for.this square footage in this proposed project may now be issued.
Fees -Paid By Exempt - Jim Kelly — Check No.
Bank Name/Recipient of Certificate Telephone 415-722-9388
Funding Exempt
BY Dr. Gary Rutherford
Superintendent
Fee collected /exempte Sharon cGilv Payment Recd : "�_��$000 =71
Z,
ibver/U�dei�
Signature
NOTICE: Pursudfit to Government Code Section 6020(d)(1), this will strve 0 notify you that the 90 -day approval period in which you may protest the fees
or other payment identified above will begin to run from the date on whifh tV building or installation permit for this project is issued, or from the date on
which those amounts are paid to the District(s) or to another public entit�.Athorized to collect them on the District('s) behalf, whichever is earlier.
NOTICE: This Document NOT VALID without embossed seal
Embossed Original - Building Department Applicant Copy - Applicant/Receipt Copy - Accounting
A
February 11, 2015
Mr. Jerry Hostetter
121 Eshelman Road
Lancaster, PA 17601
Re: California Village, Lot 3, Tr. 30056. -at 78234 Pinnacle Point
Architecturat Modification Concept — Enlarge Guest Room
Dear Mr. Hostetter,
e ai n — -T— ��i&�I_ljesign Review
siat s6i�7 oification from th& ra&i ion 6it
This correi�o_n&e_n al I d . e gn for the enclosure of your existing patio was
Committee ("ADRU) that the conceptu si
discussed at the February 5, 2015 meeting.
enlarge a guest bedroom by enclosing an existmig pationwasTLapp—roved, i c - nc-61–m
The request to final: corisid ation pri . or to start' g work in the field. As a
Formal plans should -be submitted for . er. gress from the room has
courtesy comment you may want to verify with the City that proper* e
been provided based,, . on the current City codes. The -committee suggests some additional
detailing at the top of the parapet to be consistent with the adjacent parapet.design.
We look forward.to receiving your- -final working drawings A submittal schedule and a remodel
a
application are attached: for your use with your fiiture submittal. ..Please contact Brook Marsh 11
at 760-219-8057 or by email at DRCFacilitAior@gmai I I.Com with any questions regarding this
matter.
Sincerely, AND DESIGN REVIEW COMMITTEE
TRADITIpARCHITECTUR4L
A A , . t") 4 11
By: %.V- K:j V "L/ -
Title: ----------- Date.
cc: ADRC File
o by,the*ADRC may be.aPP0410-10 the Board of Directorsfor the Aj : sociation. Ifyoll visli to pursue an
Purstiont to Cal. Civil Code, any rejectio ge do.
nnn I PaL Dlease contact the Association's property manager so that you maybe put on the next meeting a n
RESORT MANAGEMENT
PALM DESERT, CALIFORNIA 92255-4387
1 A 07711
42-635 MELANIE PLACE, SUITE.103 - PALM UESERTUALIFORN
TELEPHONE (760) 346-1161 - FAX(760)346-9918
r YOUNG
ENGINEERING
l( ) S E R V I C E S
Letter of Transmittal
To: City of La Quinta Today's Date:
78-495 Calle Tampico City Due Date:
La Quinta, CA 92253 Project Address:
Attn: Kay Plan Check #:
Submittal: El 1st
0 2nd
El 3rd
We are forwarding: Z By Messenger El
Includes: # Of Descriptions:
Copies:
5-26-15
5-25-15
78234 Pinnacle Point
BRES 2015-0108,
0
4 th
El
5 th
El
Other:
By Mail (Fed
Ex or UPS)
Includes:
# Of
and Roof
Copies:
El Your Pickup
Descriptions:
1 Revised Structural Plans
Revised Struct. Calcs
Revised Truss
Revised Soils Report
Approved Structural Plans
App roved Structural Calcs
-Approved Truss Calcs
Approved Soils Report
Other:
Comments: Structural content is approvable.
9116%90 L; I V QJJ
If you have any questions, please call. MAY 2 6 2015
Time =.75 HR ._..F1TT0FU QUINTA
WWMMW"1 I T W&VOLOPMENT
Th is Material
ID
Other: n
Se nt for:
Your Files
Your Review
Checking
BY: Kathryn Samuels
Palm Desert Office: (760) 772-5107
Other:
ED Per Your Request
El Approval
E] At the request of:
Structural Plans
1 Structural Calculations
El
El
Truss Calculations Floor
and Roof
El
Soils Report
El
Structural Comment List/
El
Responses
13
Redl i ned. Structural Plans
El
El
Redlined'Structural Calcs
El
E]
Redlined Truss Calcs
El
1:1
Redlined Soils Reports
El
El Your Pickup
Descriptions:
1 Revised Structural Plans
Revised Struct. Calcs
Revised Truss
Revised Soils Report
Approved Structural Plans
App roved Structural Calcs
-Approved Truss Calcs
Approved Soils Report
Other:
Comments: Structural content is approvable.
9116%90 L; I V QJJ
If you have any questions, please call. MAY 2 6 2015
Time =.75 HR ._..F1TT0FU QUINTA
WWMMW"1 I T W&VOLOPMENT
Th is Material
ID
Other: n
Se nt for:
Your Files
Your Review
Checking
BY: Kathryn Samuels
Palm Desert Office: (760) 772-5107
Other:
ED Per Your Request
El Approval
E] At the request of:
-CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD uia'f% rf CF1 R -PRF -01
Project Name:. Hostetter Guest Sitting Add Calculation Date/Time: 20:56, Thu, Apr 3 �'j Page I of 6
Calculation Description: Title 24 Analysis
Input File Name: Hostefter-Stracts-15.xml
AAAV I I
GENERAL INFORMATION
0 (L R
01
01
Project Name Hostetter Guest Sitting Add
CITY OF
I A
This building Incorporates featu r6s. that require field testing and/or,�'vke'-r:iiicaRti�o�'n'.by A�'_certifie`d HERS r'a4ite'r un6r`the supervision ofa CEC a
02
Calculation Description Title 24 Analysis
This building incorporates one 01 ffibre Speciii Feaiui6s show-h-beiOw-
COMMUN11Y
DEWL-:�PMENT
03
Project Location 78-234 Pinacle
La
ENERGY USE SUMMARY
04
C ity La Quinta
05
Standards Version Compliance 2015
06
06
Zip Code 92253
07
Compliance Manager Version
BEMCmpMgr 2013-3c (710)
08
Climate Zone CZ15
09
Software Version
Energy o 6.5
Space Heating
10
Building Type Single Family
11
Front Orientation (deg/Cardinal) 0
12
Project Scope Newly Constructed
13
Number of Dwelling Units
1
-1.28
14
Total Cond. Floor Area (FT 2) 212
15
Number of Zones
1
6.77
16
Slab Area (FT 2) 212
17
Number of Stories
I
18
Addition Cond. Floor Area N/A
19
Natural Gas Available
Yes LLI
op
20
Addition Slab Area (FT2) N/A
21
Glazing Percentage
36.8./ig <
to
IL J F
n
h % npr�s - �'� -Am I
COMPLIANCE RESULTS
0 (L R
01
Building Complies with Computer Performafi6i
EL C -C
02
This building Incorporates featu r6s. that require field testing and/or,�'vke'-r:iiicaRti�o�'n'.by A�'_certifie`d HERS r'a4ite'r un6r`the supervision ofa CEC a
rovi e
03
This building incorporates one 01 ffibre Speciii Feaiui6s show-h-beiOw-
JV
La
ENERGY USE SUMMARY
04
05
06
07
08
Energy Use
(kTDV/ft2-yr)
Standard
Design
Proposed
Design
Compliance
Margin
Percent
Improvement
Space Heating
0.35
0.50
-0.15
-42.9%
Space Cooling
276.98
278.26
-1.28
-0.5%
IAQ Ventilation
6.77
6.77
0.00
0.0%
Water Heating
77.42
74.85
2.57
3.3%
Photovoltaic Offset
----
0.00
0.00
----
Compliance Energy Total
361.52
360.38
1.14
0.3%
Registration Number: 215-NO075394B-000000000-0000 Registration Date/Time: 2015-04-30 21:01:43 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CFlR-02272015-710 Report Generated at: 2015-04-30 20:56:40
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Hostetter Guest Sitting Add Calculation Date/Time: 20:56, Thu, Apr 30, 2015
Calculation Description: Title 24 Analysis Input File Name: Hostetter-Stracts-15.xml
REQUIRED SPECIAL FEATURES
The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis.
Window overhangs and/or fins
HERS FEATURE SUMMARY
CF1 R -PRF -01
Page 2 of 6
The following is a summary of the features that must be field -verified by a certified HERS Rater as a condition for meeting the modeled energy performance for this computer analysis. Additional detail is
provided in the building components tables below.
Building -level Verifications:
High Quality Insulation Installation (QII)
IAQ mechanical ventilation
Cooling System Verifications:
- -- None --
HVAC Distribution System Verifications:
* -_ None --
Domestic Hot Water System Verifications:
- -- None --
ENERGY DESIGN RATING
This is the sum of the annual TDV energy consumption for energy use components, included in the performance compliance appLoach for the Standard Design Building (Energy Budget) and the annual
TDV energy consumption for lighting and components not regulated 15;l4le 24, PAh 6.(gu6h i -s d6ine"'q'ti:c-ap"Pi�i'apht'�es' 5��d consumer electronics) and accounting for the annual TDV energy offset by an
on-site renewable energy system. 4
04
Refere'nce Efie Energy Design Rating
._Fg� Use'�+ 1
Margin Percent Improvement
E
Total Energy (kTDV/f2-yr)*
t569.07, - � -0 1 - 567.93
U I - 1_t I I
1.14 0.2%
I I
* includes calculated Appliances and Miscellaneous Energy Use (AMEU)
BUILDING - FEATURES INFORMATION
01
02
03
04
05
06
07
Project Name
Conditioned Floor Area (ft2)
Number of Dwelling
Units
Number of Bedrooms
Number of Zones
Number of Ventilation
Cooling Systems
Number of Water
Heating Systems
Hostetter Guest Sitting Add
212
1
3
1
1
1
ZONE INFORMATION
01
02
03
04
05
06
07
Zone Name
Zone Type
HVAC System Name
Zone Floor Area
(ft)
Avg. Ceiling
Height
Water Heating System I
Water Heating System 2
Casita
Conditioned
HVAC exl
212
14
DHW Sys 1
Registration Number: 215-NO075394B-000000000-0000 Registration Date/Time: 2015-04-30 21:01:43 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CFlR-02272015-710 Report Generated at: 2015-04-30 20:56:40
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Hostetter Guest Sifting Add Calculation Date/Time: 20:56, Thu, Apr 30, 2015
Calculation Description: Title 24 Analysis
Input File Name: Hostefter-Stracts-15.xml
CFIR-PRF-01
Page 3 of 6
OPAQUE SURFACES
01
02
03
04
05
06
07
01
02
03
04
05
06
07
08
Name
Zone
Construction
Azimuth
Orientation
GrossArea(ft)
Window& Door Area (ft2)
Tilt(deg)
N Wall
Casita
R-21 Wall (W.21.2x6.16)
0
Front
250
72
90
S Wall
Casita
R-21 Wall (W.21.M.116)
180
Back
250
6
90
WWall
Casita
R-1 3 Wall + RI 3new
270
Right
250
1
12.0
Roof
Casita
R-38 Roof Attic
1x2
Window
212
1.0
2.0
ATTIC
01 02 03 04 05 06 07 08
Name Construction Type Roof Rise Roof Reflectance Roof Emittance Radiant Barrier Cool Roof
Attic Casita Attic RoofCasita Ventilated 3 0.1 0.85 ' No No
WINDOWS
01
02
03
04
05
06
07
08
09
10
Name
Type
Surface (Orientation-Ailmuth)
Width (ft)
Height (ft)
Multipl!
er
Area
(ft)
U -factor
SHGC
Exterior Shading
1.5x8
Window
N W611 (Fr6nt-0)
1.5
8.0
1
12.0
0.28
0.18
Insect Screen (default)
6x8
Window
N Wall. (Front -0)
6.0
8.0
1
48.0
0.28
1 0.18
Insect Screen (default)
1.5x8 2
Wnclow
N Wall (Front -0)
1.5
8.0
1
12.0
0.28
0.18
Insect Screen (default)
1x2
Window
S Wall (Back -180)
1.0
2.0
1
2.0
0.28
0.18
Insect Screen (default)
1x2 2
Window
S Wall (Back -180)
1.0
2.0
1
2.0
0.28
0.18
Insect Screen (default)
1x2 3
Wriclow
S Wall (Back -180) 1
1.0
1 2.0
1
2.0
0.28
0.18 1
Insect Screen (default)
Registration Number: 215-NO075394B-000000000-0000 Registration Date/Time: 2015-04-30 21:01:43 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CFIR-02272015-710 Report Generated at: 2015-04-30 20:56:40
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Hostetter Guest Sifting Add Calculation Date/Time: 20:56, Thu, Apr 30, 2015
Calculation Description: Title 24 Analysis
Input File Name: Hostetter-Stracts-15.xml
CFIR-PRF-01
Page 4 of 6
OVERHANGS AND FINS
01
02
03
04
05
06
07
Total Cavity
01
02
03
04
05
06
07
08
09
10
-7TT--F
12 13
1-14
Cavity/ Frame: no insul. / 2x4 Top Chrd
Overhang
2k4,tbp ChA of R6of TrIuss @ 24'
Left Fin
Roof Deck: Wood Sidinglsheathingldecking
Attic RoofCasita
Right Fin
Wood Framed C '160)
Window
Depth
Dist Up
Left
Extent
Right
Extent
Flap Ht.
Depth
Top Up
DistL
Bot Up
Depth
Top Up Dist R
Bot Up
1.5x8
10
0.1
10
10
0
0
0
0
0
1 0
0 0
0
6x8
10
0.1
10
10
0
0
0
0
0
0
0 0
0
1.5x8 2
10
0.1
10
10
0
0
0
0
0
0
0 0
1 0
1x2
8
0.1
8
8
0
0
0
0
0
0
0 0
0
1x2 2
8
0.1
8
8
0
0
0
0
0
0
0 0
0
1x2 3
8
0.1
8
8
0
0
0
0
0
0
0 0
0
OPAQUE SURFACE CONSTRUCTIONS
01
02
03
04
05
06
07
Total Cavity
Winter Design
Construction Name
Surface Type
Construction Type
Framing
R -value
U -value
Assembly Layers
Cavity/ Frame: no insul. / 2x4 Top Chrd
2k4,tbp ChA of R6of TrIuss @ 24'
Roof Deck: Wood Sidinglsheathingldecking
Attic RoofCasita
Attic Roofs
Wood Framed C '160)
1, 0. C
none� �3
W.644
Roofing: Light Roof (Asphaft Shingle)
Inside Finish: Gypsum Board
Ceilings (below
Cavity / Frame: R-9.1 / 2x4
R-38 Roof Attic
attic)
Wood Framed Ceiling
2x4 @ 16 in. O.C.
R 38
0.025
Over Floor Joists: R-28.9 insul.
Inside Finish: Gypsum Board
Cavity / Frame: R-21 / 2x6
Exterior Finish: Wood
R-21 Wall (W.21.2x6.16)
Exterior Walls
Wood Framed Wall
2x6 @ 16 in. O.C.
R 21
0.066
Sidinglsheathingldecking
Inside Finish: Gypsum Board
Sheathing /Insulation: R 13 Sheathing
Cavity / Frame: R- 13 / 2x4
Exterior Finish: Wood
R-1 3 Wall + R1 3new
Exterior Walls
Wood Framed Wall
2x4 @ 16 in. O.C.
R 13
0.040
Sidinglsheathingldecking
SLAB FLOORS
01 02
03 04 06 06 07
Name Zone
Area (ft2) Perimeter (ft) Edge Insul. R -value & Depth Carpeted Fraction Heated
Covered Slab Casita
212 36 None 0.8 No
Registration Number: 21,5-NO075394B-000000000-0000 Registration Date/Time: 2015-04-30 21:01:43 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF111-02272015-710 Report Generated at: 2015-04-30 20:56:40
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Hostetter Guest Sifting Add Calculation Date/Time: 20.-56, Thu, Apr 30, 2015
Calculation Description: Title 24 Analysis
Input File Name: Hostefter-Stracts-15.xml
CF1R-PRF-01
Page 5 of 6
BUILDING ENVELOPE - HERS VERIFICATION
01 02 03 04
Quality Insulation Installation (Qll) Quality Installation of Spray Foam Insulation Building Envelope Air Leakage ACH @ 50 Pa
Required Not Required Not Required
WATER HEATING SYSTEMS
01
01
02 03 04 05 06
Name
System Type Distribution Type Water Heater Number of Heaters Tsolar Fraction I[%)
1
DHW Sys 1 - 1/1
DHW Pipe Insulation, All Lines DHW Heater 1 1 1 .0%
WATER HEATERS
01
02
03
04
05
06
07
08
Name
Heater Element Type
Tank Type
Tank Volume
(gal)
Energy Factor or
Efficiency
Input Rating
Tank Exterior
Insulation
R -value
Standby Loss
(Fraction)
DHW Heater 1
Natural Gas
Small Storage
50
0.61
40000-Btu/hr
0
0
WATER HEATING - HERS VERIFICATION
01
02
03
04
05
06
07
Name
Pipe Insulation
Parallel Piping
Compact Distribution
Point -of Use
Recirculation
Control
Central DHW
Distribution
DHW Sys 1 - 1/1
---
---
---
---
---
---
IAQ (indoor Air Quality) FANS
01
02
03
04
05
06
Dwelling Unit
IAQ CFM
IAQ Wafts/CFM
IAQ Fan Type
IAQ Recovery
Effectiveness(%)
HERS Verification
SFam IAQVentRpt
32.12
0.25
Default
0
Required
COOLING VENTILATION
01 02 03 04 05
Name Cooling Vent CFM Cooling Vent Watts/CFM Total Watts Number of Fans
WH Fan 1 61 0.52459 32 1
Registration Number: 215-NO075394B-000000000-0000 Registration Date/Time: 2015-04-30 21:01:43 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CFlR-02272015-710 Report Generated at: 2015-04-30 20:56:40
I -- . CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Hostetter Guest Sitting Add
Calculation Description: Title 24 Analysis
Calculation Date/Time: 20:56, Thu, Apr 30, 2015
Input File Name: Hostefter-Stracts-15.xml
CFIR-PRF-01
Page 6 of 6
DOCUMENTATION AUTHOR'S DECLARATION STATEMENT
1. 1 certify that this Certificate of Compliance documentation is accurate and complete.
Documentation Author Name:
Documentation Author Signature:
Tim Scott
Company:
Signature Date:
Scott Design and Title 24, Inc.
2015-04-30 21:01:43
Address:
CEA/HERS Certification Identification (if applicable):
77085 Michigan Drive
City/State/Zip:
Phone:
Palm Desert, CA 92211
(760) 200-4780
RESPONSIBLE PERSON'S DECLARATION STATEMENT
I certify the following under penalty of perjury, under the laws of the State of California:
1. 1 am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design identified on this Certificate ofCompliance.
2. 1 certify that the energy features and performance specifications identified on this Certificate of Compliance conform to the requirements of Title 24, Part I and Part 6 ofthe California Code of
Regulations.
3. The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents,
worksheets, calculations, plans and specifications submitted to the enforcement a nc for a pr val with this building pe�Emit application.
_'N9 'Y — 1p_�.
Responsible Designer Name: iL
onsible! Designer Sigfiblum
Tim Scott
Company:
Date Signed -
Scott Design and Title 24, Inc.
2015-04-30 21:01:43 -
Address:
License:
77085 Michigan Drive
na
City/State/Zip:
Phone:
Palm Desert, CA 92211
(760) 200-4780
Digitally signed by CaICERTS. This digital signature is provided in order to secure the content of this registered document, and in no way implies Registration Provider responsibility for the accuracy of the
information.
Registration Number: 215-NO075394B-000000000-0000 Registration Date/Time: 2015-04-30 21:01:43 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CFIR-02272015-710 Report Generated at: 2015-04-30 20:56:40
4
I BUILDING ENERGY ANALYSIS REPORT I
PROJECT:
Hostetter'Guest Sitting Add
78-234 Pinacle
La Quinta, CA 92253
Project Designer:
Stracts Architecture
550 S. Oleander
Palm Springs, CA 92662
(760) 636-8951
Report Prepared by:
Jon Scott
Scott Design and Title 24, Inc,
77-085 Michigan Drive
Palm Desert, CA 92211
(760) 200-4780
CITY OF LA OUINTA
BUILDING & SAFETY DEPT.
APPROVED
FOR CONSTRUCTION
Job Number:
Date:
4/30/2015
RECEIVED
mAy 112015
CITY OF LA OUINTA
COMMUNITY DEVELOPMENT
The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is
authorized by the California Energy Commission for use with both the Residential and Nonresidential 2013 Building Energy Efficiency Standards.
This program developed by EnergySoft, LLC — www.energysoft.com.
Ener_qyPro 6.5 by EnergySoft User Number 6712 ID:
ItP
k
I TABLE OF CONTENTS I
Cover Page
Table of Contents
Form CF -1 R -PRF -01 -E Certificate of Compliance
Form RMS -1 Residential Measures Summary
Form MF -1 R Mandatory Measures Summary
1
2
3
9
10
I EnergyPro 6.5 by EnergySoft Job Number: ID: User Number: 6712 1
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Hostetter Guest Sitting Add Calculation Date/Time: 20:56, Thu, Apr 30, 2015
Calculation Description: Title 24 Analysis
Input File Name: Hostefter-Stracts-15.xmi
CFIR-PRF-01
Page I of 6
GENERAL INFORMATION
01
Project Name Hostetter Guest Sitting Add
Building Complies with Computer Performance
02
7-
Calculation Description Title 24 Analysis
02
This building incorporates features that require field testing andlo verification by a certified HERS rater under the supervision of a CEC-approved HERS provider.
03
Project Location 78-234 Pinacle
04
City La Quinta
05
Standards Version Compliance 2015
06
Zip Code 92253
07
Compliance Manager Version BEMCmpMgr 2013-3c (710)
08
Climate Zone CZ15
09
Software Version EnergyPro 6.5
10
Building Type Single Family
11
Front Orientation (deg/Cardinal) 0
12
Project Scope Newly Constructed
13
Number of Dwelling Units 1
14
Total Cond. Floor Area (FT2) 212
1.5 4�qj'
Number of Zones 1
16
Slab Area (FT2) 212
17
Number of Stories 1
18
Addition Cond. Floor Area N/A
I
Natural Gas Available Yes
20
Addition Slab Area (FT2), N/A
Glazing Percentage 36.8%
kl'��
COMPLIANCE RESULTS
01
Building Complies with Computer Performance
02
This building incorporates features that require field testing andlo verification by a certified HERS rater under the supervision of a CEC-approved HERS provider.
03
This building incorporates one or more Special Features show-nbelow
Aw.
ENERGY USE SUMMARY
04
05.
Z
06
07
08
Energy Use
(kTDV/ft2-yr)
Standa'rd
A)"
ign
Proposed
Design
Compliance
Margin
Percent
Improvement
Space Heating
0.50
-0.15
-42.9%
Space Cooling
276.98
278.26
-1.28
-0.5%
IAQ Ventilation
6.77
6.77
0.00
0.0%
Water Heating
77.42
74.85
2.57
3.3%
Photovoltaic Offset
----
0.00
0.00
----
Compliance Energy Total
361.52
360.38
1.14
0.3%
Registration Number:
CA Building Energy Efficiency Starid6rds - 2013 Residential Compliance
Registration Date/Time:
Report Version - CF111-02272015-710
HERS Provider:
Report Generated at: 2015-04-30 20:56:35
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Hostetter Guest Sitting Add Calculation Date/Time: 20:56, Thu, Apr 30, 2015
Calculation Description: Title 24 Analysis Input File Name: Hostetter-Stracts-15.xml
REQUIRED SPECIAL FEATURES
The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis.
- Window overhangs and/or fins
CFIR-PRF-01
Page 2 of 6
HERS FEATURE SUMMARY
The following is a summary of the features that must be field -verified by a certified HERS Rater as a condition for meeting the modeled energy performance forthis computer analysis. Additional detail is
provided in the building components tables below.
Building -level Verifications:
High Quality Insulation Installation (QII)
IAQ mechanical ventilation
Cooling System Verifications: b
None -- 0
V_AC Distribution System Verifications:
�None --
o_m_estic Hot Water System Verifications:
-- None
ENERGY DESIGN RATING
This is the sum of the annual TDV energy consumption for energy use components included in th4lperformance compliance approach for the Standard Design Building (Energy Budget) and the annual
TDV energy consumption for lighting and components not regulated by Title 24, Part 6 (such asVomestic appliances and consumer electronics) and accounting for the annual TDV energy offset by an
on-site renewable energy system.
04
Reference Energy Use #,,IV
Energy Design Rating Margin Percent Improvement
Total Energy (kTDV/f2-yr)*
569.07
567.93 1.14 0.2%
includes calculated Appliances and Miscellaneous Energy Use (AMEU) W
- do
BUILDING - FEATURES INFORMATION
01
02
03
04
05
06
07
Project Name
Conditioned Floor Area (ft2)"
Ndmber of Dwelling
r *e Units
Number of Bedrooms
Number of Zones
Number of Ventilation
Cooling Systems
Number of Water
Heating Systems
Hostetter Guest Sitting Add
212
1
3
1
1
1
ZONE INFORMATION .0
01
02
fAr
03
04
05
06
07
ZoneName
Re-
Zonej�,Re
HVAC System Name
Zone Floor Area
(ft)
Avg. Ceiling
Height
Water Heating System 1
Water Heating System 2
Casita
Conditio'Aed
HVAC exl
212
14
DHW Sys 1
Registration Number: mc% Registration Date/Time: HERS Provider:
CA Building Energy Efficiency Staridaeds - 2013 Residential Compliance Report Version - CFlR-02272015-710 Report Generated at: 2015-04-30 20:56:35
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Hostetter Guest Sifting Add Calculation Date/Time: 20:56, Thu, Apr 30, 2015
Calculation Description: Title 24 Analysis
Input File Name: Hostetter-Stracts-15.xmi
CFIR-PRF-01
Page 3 of 6
OPAQUE SURFACES
01
02
03 A�-
04
05
06
07
01
02
03
04
05
06
07
08
Name
Zone
Construction
Azimuth
Orientation
Gross Area (ft)
Window & Door Area (ft2)
Tilt (deg)
N Wall
Casita
R-21 Wall (W.21.2x6.16)
0
Front
250
72
90
S Wall
Casita
R-21 Wall (W.21.2x6.16)
180
Back
250
6
90
WWall
Casita
R-1 3 Wall + R1 3new
270
Right
250
1
90
Roof
Casita
R-38 Roof Attic
1x2
Wnclow
212
1.0
2.0
ATTIC
01 02 03 04 05 06 07 08
Name Construction Type Roof Ri§b- Roof Reflectance Roof Emittance Radiant Barrier Cool Roof
Attic Casita Attic RoofCasita Ventilated "3p 0.1 0.85 No No
WINDOWS
01
02
03 A�-
04
05
06
07
08
09
10
Name
Type
Surface (Orientation -Azimuth),,.
Width (ft)
Height (ft)
multipli
er
Area
M2
U -factor
SHGC
Exterior Shading
1. 5x8
Window
N Wall (Front -0)
1.5
8.0
1
12.0
0.28
0.18
Insect Screen (default)
6x8
Wnclow
N Wall (Front -0) Avv-
6.0
8.0
1
48.0
0.28
0.18
Insect Screen (default)
1.5x8 2
Wridow
N Wall (Front -0
1.5
8.0
1
12.0
0.28
0.18
Insect Screen (default)
1x2
Wnclow
S Wall (Back:41,9
1.0
2.0
1
2.0
0.28
0.18
Insect Screen (default)
1x2 2
Wriclow
S Wall (Back!'l -80)
1.0
2.0
1
2.0
0.28
0.18
Insect Screen (default)
1x2 3
Window
S Wall (Wa`6kf"! 80)
1.0
2.0
1
2.0
0.28
0.18
1 Insect Screen (default)
Registration Number:
CA Building Energy Efficiency Stariclar , ds - 2013 Residential Compliance
Registration Date/Time:
Report Version - CFIR-02272015-710
HERS Provider:
Report Generated at: 2015-04-30 20:56:3S
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Hostetter Guest Sitting Add Calculation Date/Time: 20:56, Thu, Apr 30, 2015
Calculation Description: Title 24 Analysis
Input File Name: Hostefter-Stracts-15.xml
CF1R-PRF-01
Page 4 of 6
OVERHANGS AND FINS
01
02
03
04
05
06
07
Carpeted Fraction Heated
Covered Slab Casita
212 36
None
Total Cavity
01
02
03
04
05
06
07
08
09
10
11
12 13
F-1 4_
Cavity I Frame: no insul. 12x4 Top Chrd
Overhang
2x4 Top Chd�rd'of Roof Truss 24
Left Fin
Roof Deck Wood Sidinglsheathingldecking
Attic RoofCasita
Right Fin
Wood Framed Ceiling
Window
Depth
Dist Up
Left
Extent
Right
Extent
Flap Ht.
Depth
Top Up
DistL
Bot Up
Depth
Top Up Dist R
Bot Up
1.5x8
10
0.1
10
10
0
1 0
0
0
0
0
0 0
0
6x8
10
0.1
10
10
0
0
0
0
0
0
0 0
0
1.5x8 2
10
0.1
10
10
0
0
0
0
0
0
0 0
1 0
1x2
8
0.1
8
8
0
011*.,
0
0
0
0
0 0
0
1x2 2
8
0.1
8
8
0
&�w
0
0
0
0
0 0
0
1x2 3
8
0.1
8
8
0
,Otb
0
0
0
0
0 0
tl�y
OPAQUE SURFACE CONSTRUCTIONS
01
02
03
04
05
06
07
Carpeted Fraction Heated
Covered Slab Casita
212 36
None
Total Cavity
Winter Design
Construction Name
Surface Type
Construction Type
Framing
R -value
U -value
Assembly Layers
Cavity I Frame: no insul. 12x4 Top Chrd
2x4 Top Chd�rd'of Roof Truss 24
Roof Deck Wood Sidinglsheathingldecking
Attic RoofCasita
Attic Roofs
Wood Framed Ceiling
in. O.C.
none
0.644
Roofing: Light Roof (Asphaft Shingle)
Inside Finish: Gypsum Board
Ceilings (below
Cavity / Frame: R-9.1 / 2x4
R-38 Roof Attic
attic)
Wood Framed Ceiling
2x4 @ 16 in. O.C.
R 38
0.025
Over Floor Joists: R-28.9 insul.
14&1
Inside Finish: Gypsum Board
Cavity / Frame: R-21 / 2x6
Exterior Finish: Wood
R-21 Wall (W.21.M.16)
Exterior Walls
Wood Framed 11
2x6 @ 16 in. O.C.
R 21
0.066
Sidinglsheathingldecking
Inside Finish: Gypsum Board
Sheathing /Insulation: R 13 Sheathing
Cavity / Frame: R- 13 / 2x4
Exterior Finish: Wood
R-1 3 Wall + R1 3new
Exterior Walls
Woocl�llhra�necl Wall
2x4 @ 16 in. O.C.
R 13
0.040
Sidinglsheathingldecking
owl
SLAB FLOORS
01 C402
03 04
05
06 07
�K-4
Name %A, Zone
Area (ft2) Perimeter (ft)
Edge Insul. R -value & Depth
Carpeted Fraction Heated
Covered Slab Casita
212 36
None
0.8 No
Registration Number: 41
,
A
CA Building Energy Efficiency StaridA'rds - 2013 Residential Compliance
Registration Date/Time:
Report Version - CFIR-02272015-710
HERS Provider:
Report Generated at: 2015-04-30 20:56:35
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Hostetter Guest Sifting Add Calculation Date/Time: 20:56, Thu, Apr 30, 2015
Calculation Description: Title 24 Analysis
Input File Name: Hostefter-Stracts-15.xml
CF1R-PRF-01
Page 5 of 6
BUILDING ENVELOPE - HERS VERIFICATION
01 02 03 04
Quality Insulation Installation (QII) Quality Installation of Spray Foam Insulation Building Envelope Air Leakage ACH @ 50 Pa
Required Not Required Not Required ---
WATER HEATING SYSTEMS
01
01
02 03 04 05 06
Name
System Type Distribution Type Water Heater Number of Heaters Solar Fraction I(%)
DHW Sys 1 - 1/1
DHW Pipe Insulation, All Lines DHW Heater 1 1 .0%
WATER HEATERS
01
01
02
03
04
05
06
07
08
k��Jj
C!'A'
IAQ Recovery
Effectiveness(%)
HERS Verification
Recirculation
Central DHW
Name
Tank Exterior
Piping
Compact Distribution
Point -of Use
Control
Tank e
lv§ M
Energy Factor or
Insulation
Standby Loss
Name
Heater Element Type
Tank Type
.�06
Efficiency
Input Rating
R -value
(Fraction)
I
DHW Heater 1
Natural Gas
Small Storage
50
0.61
40000-Btu/hr
0
0
4r
WATER HEATING - HERS VERIFICATION
01
02
0
04
05
06
07
IAQ CFM
IAQ Watts/CFM
k��Jj
C!'A'
IAQ Recovery
Effectiveness(%)
HERS Verification
Recirculation
Central DHW
Name
Pipe Insulation
Piping
Compact Distribution
Point -of Use
Control
Distribution
,,faeallel
DHW Sys 1 - 1/1
---
---
---
IAQ (Indoor Air Quality) FANS
01
02
03
04
05
06
Dwelling Unit
IAQ CFM
IAQ Watts/CFM
IAQ Fan Type
IAQ Recovery
Effectiveness(%)
HERS Verification
SFam IAQVentRpt
32.12
0.25
Default
0
Required
6o
COOLING VENTILATION
01 02 03 04 05
Name Cooling Vent CFM Cooling Vent Wafts/CFM Total Watts Number of Fans
WH Fan 1 61 0.52459 32 1
Registration Number:
CA Building Energy Efficiency Standa�ds - 2013 Residential Compliance
Registration Date/Time:
Report Version - CFIR-02272015-710
HERS Provider:
Report Generated at: 2015-04-30 20:56:35
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Hostetter Guest Sifting Add Calculation Date/Time: 20:56, Thu, Apr 30, 2015
Calculation Description: Title 24 Analysis Input File Name: Hostetter-Stracts-15.xmi
CF1 R -PRF -01
Page 6 of 6 ,
DOCUMENTATION AUTHOR'S DECLARATION STATEMENT
1. 1 certify that this Certificate of Compliance documentation is accurate and complete.
Documentation Author Name:
Documentation Author Signature -
z�n-*"'A\
Jon Scott
Company:
Signature Date:
Scott Design and Title 24, Inc,
4/30/2015
Address:
CEA1HERS Certification Identification (If applicable):
77-085 Michigan Drive
City/State ip-
ffafrn Desert, CA 92211
Phone:
200-4780
(760)
RESPONSIBLE PERSON'S DECLARATION STATEMENT
I certify the following under penalty of perjury, under the laws of the State of California:
1. 1 am eligible under Division 3 of the Business and Professions Code to accept responsibility fo�,tR�e building design identified on this Certificate ofCompliance.
2. 1 certify that the energy features and performance specifications identified on this Certificate of,66'mpliance conform to the requirements of Title 24, Part 1 and Part 6 ofthe California Code of
Regulations. tq
3. The building design features or system design features identified on this Certificate of CornAl'iance are consistent with the information provided on other applicable compliance documents,
worksheets, calculations, plans and specifications submitted to the enforcement agency,j�� approval with this building permit application.
Responsible Designer Name:
Responsible Designer Signature:
Stracts Architecture
Company:
Date Signed:
Stracts Architecture
Address:
License:
560 S. Oleander
City/State/Zip:
Phone:
Palm Springs, CA 92662
(760) 636-8951
Registration Number: Registration Date/Time:
CA Building Energy Efficiency Staricl�Ms - 2013 Residential Compliance Report Version - CF113-02272015-710
HERS Provider:
Report Generated at: 2015-04-30 20:56:35
RESIDENTIAL MEASURES SUMMARY
RMS -1
Project Name
Hostetter Guest Sitting Add
Building Type [0 Single Family 0 Addition Alone
0 Multi Family 0 Existing+ Addition/Alteration
Date
413012015
Project Address
78-234 Pinacle La Quinta
California Energy Climate Zone
CA Climate Zone 15
Total Cond. Floor Area
212
Addition
n1a
# of Un Fts-
INSULATION
Construction Type
Area
Cavity (ft) Special Features Status
Roof Wood Framed Attic
R 38 212 New
Waft Wood Framed
R 21 422 New
Wall Wood Framed
R 13 250 Rigrid=R- 13. 0 Existing
Slab Unheated Slab -on -Grade
- no insulation 212 Perim = 36' New
Demising, Wood Framed
R 13 12 Rigid=R-13.0 New
FENESTRATION
Orientation Area(ft)
I Total Area: 781 Glazing Percentage: 36.8 % New/Altered Average U -Factor: 0.28
U -Fac SHGC Overhang. Sidefins Exterior Shades Status
Front (N) 72.0
0.280 0.18 10.0 none Bug Screen New
Rear (S) 6.0
0.280 0.18 8.0 none Bug Screen New
HVAC SYSTEMS
Qty. Heating
Min. Eff Cooling Min. Eff Thermostat Status
1 Central Furnace
80% AFUE Split Air Conditioner 14.0 SEER Setback
Existing
HVAC DISTRIBUTION Duct
Location Heating Cooling Duct Location R -Value Status
HVAC ex Ducted
Ducted Attic 8.0 Altered
WATER HEATING
Qty. Type
Gallons Min. Eff Distribution Status
EnergyPro 6.5 by EnergySoft User Number: 6 712 RunCode: 2015-04-3OT20:57:45 ID:
Paqe 9 of 13
2'013 Low -Rise Residential Mandatory Measures Summary
NOTE: Low-rise residential buildings subject to the Standards must comply with all applicable mandatory measures listed, regardless of the
com,oliance apDroach used ExceDtions mav aDDlv. Review the resvective code section for more information -
Building Envelope Measures:
§ I 10.6(a) 1:
Doors and windows between conditioned and unconditioned spaces are manufactured to limit air leakage.
§ I 10.6(a)5:
Fenestration products (except field -fabricated windows) have a label listing the certified U -Factor, certified Solar Heat Gain
Coefficient (SHGC), and infiltration that meets the requirements of § 10- 111 (a).
§110.7:
Exterior doors and windows are weatherstripped; all joints and penetrations are caulked and sealed.
§1 10.8(a):
Insulation specified or installed meets Standards for Insulating Material. Indicate type and include on the CF2R.
§ 110. 8 (i):
The thermal emittance and aged solar reflectance values of the cool roofing material meets the requirements of § I 10.8(i) when the
installation of a cool roof is specified on the CF I R.
§ 110.80):
A radiant barrier shall have an emittance of 0.05 or less when the installation of a radiant barrier is specified on the CF] R.
Minimum R-30 insulation in wood -frame ceiling; or the weighted average U -factor sh t exceed 0.031. Minimum R-19 in a
§ I 50.0(a):
rafter roof alteration. Attic access doors shall have permanently attached insulation using adhesive or mechanical fasteners. The
attic access shall be gasketed to prevent air leakage.
§ I 50.0(b):
Loose fill insulation shall conform with manufacturer's installed design labeled R -value.
§ 1 50.0(c):
Minimum R- 13 insulation in 2x4 inch wood ftamin�wall or have a U -factor of 0. 102 or less (R- 19 in 2x6 or 0.074 maximum U -
factor).
§ I 50.0(d):
Minimum R-19 insulation in raised wood -frame floor or 0.037 maximum U -factor.
In Climate Zones 14 and 16 a Class 11 vapor retarder shall be installed on the conditioned space side of all insulation in all exterior
§ I 50.0(g)]:
walls, vented attics and unvented attics with air -permeable insulation.
§ I 50.0(g)2:
In Climate Zones ]- 16 with unvented crawl spaces the earth floor of the crawl space shall be covered with a Class I or Class 11
vapor retarder.
In a building having a controlled ventilation crawl space, a Class I or Class 11 vapor retarder shall be placed over the earth floor of
§ I 50.0(g)3:
the crawl space to reduce moisture entry and protect insulation from condensation, as specified in the exception to Section
150.0(d).
§ 150.0(1):
Slab edge insulation shall: have a water absorption rate, for the insulation material alone without facings, no greater than 0.3%;
have water vapor permeance rate is no greater than 2.0 perm/inch, be protected from physical damage and UV light deterioration;
and when installed as part of a heated Slab floor meets the requirements of § I 10.8(g).
§ I 50.0(q):
Fenestration, including skylights, separating conditioned space from unconditioned space or outdoors shall have a maximum U -
factor of 0.58; or the weighted average U -factor of all fenestration shall not exceed 0.58.
Fireplaces, Decorative Gas Appliances and Gas Log Measures:
§ I 50.0(e) I A:
Masonry or factory -built fireplaces have a closable metal or glass door covering the entire opening of the firebox.
§150.0(e)]B:
Masonry or factory -built fireplaces have a combustion outside air intake, which is at least six square inches in area and is
equipped with a readily accessible, operable, and tight -fitting damper or a combustion -air control device.
§ I 50.0(e) I C:
Masonry or factory -built fireplaces have a flue damper with a readily accessible control.
§150.0(e)2:
Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the outside
of the building, are prohibited.
Space Conditioning, Water Heating and Plumbing System Measures:
§ 110.0-§ 110.3:
HVAC equipment, water heaters, showerheads, faucets and all other regulated appliances are certified to the Energy Commission.
§ I 10.3(c)5:
Water heating recirculation loops serving multiple dwelling units meet the air release valve, backflow prevention, pump isolation
valve, and recirculation loop connection requirements of § I 10.3(c)5.
Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces, household cooking appliances (appli-
§110.5:
ances without an electrical supply voltage connection with pilot lights that consume less than 150 Btu/hr are exempt), and pool
and spa heaters.
§ I 50.0(h) 1:
Heating and/or cooling loads are calculated in accordance with ASHRAE, SMACNA or ACCA using design conditions specified
in §150.0(h)2.
§ I 50.0(h)3A:
Installed air conditioner and heat pump outdoor condensing units shall have a clearance of at least five feet from the outlet of any
dryer vent.
§ I 50.0(i):
Heating systems are equipped with thermostats that meet the setback requirements of § I 10.2(c).
§ 150.00) 1 A:
Storage gas water heaters with an energy factor equal to or less than the federal minimum standards shall be externally wrapped
with insulation having an installed thermal resistance of R- 12 or greater.
§ 150.00)] B:
Unfired hot water tanks, such as storage tanks and backup storage tanks for solar water -heating systems, have R- 12 external
insulation or R -I 6 internal insulation where the internal insulation R -value is indicated on the exterior of the tank.
For domestic hot water system piping, whether buried or unburied: the first 5 feet of hot and cold water pipes from the storage
tank, all piping with a nominal diameter of 3/4 inch or larger, all piping associated with a domestic hot water recirculation system
§150.00)2A:
regardless of the pipe diameter, piping from the heating source to storage tank or between tanks, piping buried below grade, and
all hot water pipes from the heating source to kitchen fixtures must be insulated according to the requirements of TABLE 120.3-
A.
§ I 50.00)2B:
All domestic hot water pipes that are buried below grade must be installed in a water proof and non -crushable casing or sleeve
that allows for installation, removal, and replacement of the enclosed pipe and insulation.
2 . 013 Low -Rise Residential Mandatory Measures Summary
§150.00)2C:
Pipe for cooling system lines shall be insulated as specified in § I 50.00)2A * Piping insulation for steam and hydronic heating
systems or hot water systems with pressure > 15 psig shall meet the requirements in TABLE 120.3-A.
§ 150.00)3:
Insulation is protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind.
Insulation exposed to weather shall either be rated for outdoor use or installed with a cover suitable for outdoor service. For
§150.00)3A:
example, protected by aluminum, sheet metal, painted canvas, or plastic cover. Cellular foam insulation protected as specified or
painted with coating that is water retardant and provides shielding from solar radiation that degrades the material.
Insulation covering chilled water piping and refrigerant suction piping located outside the conditioned space shall have a Class I
§ I 50.00)3B:
or Class 11 vapor retarding facing, or the insulation shall be installed at the thickness that qualifies as a Class I or Class 11 vapor
retarder.
Systems using gas or propane water heaters to serve individual dwelling units shall include: a 120V electrical receptacle within 3
feet of the water heater; a Category III or IV vent, or a Type B vent with straight pipe between the outside termination and the
§ I 50.0(n)]:
space where the water heater is installed-, a condensate drain that is no more than 2 inches higher than the base of the installed
water heater, and allows natural draining without pump assistance; and a gas supply line with a capacity of at least 200,000
Btu/hr.
§ I 50.0(n)2:
Recirculating loops serving multiple dwelling units shall meet the requirements of § I 10.3(c)5.
§ I 50.0(n)3:
Solar water -heating systems and collectors shall be certified and rated by the Solar Rating and Certification Corporation (SRCC)
or by a -testing agency approved by the Executive Director.
Ducts and Fans Measures:
All air -distribution system ducts and plenums installed are sealed and insulated to meet the requirements of CMC §601.0, §602.7
§603.0, §604.0, §605.0 and ANSI/SMACNA-006-2006 HVAC Duct Construction Standards Metal and Flexible 3rd Edition.
Supply -air and return -ail' ducts and plenums are insulated to a minimum installed level of R-6.0 (or higher if required by CMC
§605.0) or enclosed entirely in directly conditioned space as confirmed through field verification and diagnostic testing
(RA3.1.4.3.8). Connections of metal ducts and inner core of flexible ducts are mechanically fastened. Openings shall be sealed
§ I 50.0(m) 1:
with mastic, tape, or other duct -closure system that meets the applicable requirements of UL 181, UL 181 A. or UL 181B or
aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings greater than 'A inch, the
combination of mastic and either mesh or tape shall be used. Building cavities, support platforms for air handlers, and plenums
defined or constructed with materials other than sealed sheet metal, duct board or flexible duct shall not be used for conveying
conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms
shall not be compressed to cause reductions in the cross-sectional area of the ducts.
Factory -Fabricated Duct Systems shall comply with specified requirements for duct construction, connections, and closures; joints
§ I 50.0(m)2:
and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such tape is
used in combination with mastic and draw bands.
§150,.O(m)3-6:
Field -Fabricated Duct Systems shall comply with requirements for: pressure -sensitive tapes, mastics, sealants, and other
requirements specified for duct construction; duct insulation R -value ratings: duct insulation thickness: and duct labeling.
§ I 50.0(m)7:
All fan systems that exchange air between the conditioned space and the outside of the building must have backdraft or automatic
dampers.
§ I 50.0(m)8:
Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated dampers
except combustion inlet and outlet air openings and elevator shaft vents.
Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind but not
§ I 50.0(m)9:
limited to the following: insulation exposed to weather shall be suitable for outdoor service. For example, protected by aluminum,
sheet metal, painted canvas, or plastic cover. Cellular foam insulation shall be protected as above or painted with a coating that is
water retardant and provides shielding from solar radiation.
§ I 50.0(m) 10:
Flexible ducts cannot have porous inner cores.
When space conditioning systems use forced air duct systems to supply conditioned air to an occupiable space, the ducts shall be
§ I 50.0(m) 11:
sealed and duct leakage tested, as confirmed through field verification and diagnostic testing, in accordance with Reference
Residential Appendix RA3.
Mechanical systems that supply air to an occupiable space through ductwork exceeding 10 feet in length and through a thermal
§150.0(m)12:
conditioning component, except evaporative coolers, shall be provided with air filter devices that meet the requirements of
§ I 50.0(m) 12.
Space conditioning systems that utilize forced air ducts to supply cooling to an occupiable space shall have a hole for the
placement of a static pressure probe (HSPP), or a permanently installed static pressure probe (PSPP) in the supply plenum. The
§ I 50.0(m) 13:
space conditioning system must also demonstrate airflow �� 350 CFM per ton of nominal cooling capacity through the return
grilles, and an air -handling unit fan efficacy :S 0.58 W/CFM as confirmed by field verification and diagnostic testing, in
accordance with Reference Residential Appendix RA3.
Zonally controlled central forced air cooling systems shall be capable of simultaneously delivering, in every zonal control mode,
§ I 50.0(m)l 5:
an airflow from the dwelling, through the air handier fan and delivered to the dwelling, of �! 350 CFM[ per ton of nominal cooling
capacity.. and operating at an air -handling unit fan efficacy of:5 0.58 W/CFM as confirmed by field verification and diagnostic
testing, in accordance with Reference Residential Appendix RA3.
All dwelling units shall meet the requirements of ASHRAE Standard 62.2. Neither window operation nor continuous operation of
§ I 50.0(o):
central forced air system air handlers used in central fan integrated ventilation systems are permissible methods of providing the
Whole Building Ventilation.
§ I 50.0(o) I A:
Whole Building Ventilation airflow shall be confirmed through field verification and diagnostic testing, in accordance with
Reference Residential Appendix RA3.
Pool and Spa Heating Systems and Equipment Measures:
Any pool or spa heating system shall be certified to have: a thermal efficiency that complies with the Appliance Efficiency
§ I 10.4(a):
Regulations; an on-off switch mounted outside of the heater that allows shutting off the heater without adjusting the thermostat
setting; a permanent weatherproof plate or card with operating instructions; and shall not use electric resistance heating.
2 1 013 Low -Rise Residential Mandatory Measures Summary
§ I 10.4(b) 1:
Any pool or spa heating equipment shall be installed with at least 36 inches of pipe between filter and heater or dedicated suction
and return lines. or built-up connections for future solar heating.
§ I 10.4(b)2:
Outdoor pools or spas that have a heat pump or gas heater shall have a cover.
§ I 10.4(b)3:
Pools shall have directional inlet , s that adequately mix the pool water, and a time switch that will allow all pumps to be set or pro-
grammed to run only during off-peak electric demand periods.
§ 110.5:
Natural gas pool and spa heaters shall not have a continuous burning pilot light.
§ I 50.0(p):
Residential pool systems or equipment shall meet specified pump sizing. flow rate, piping, filters. and valve requirements.
Lighting Measures:
§ 110.9:
All lighting control devices and systems, ballasts, and luminaires shall meet the applicable requirements of § 110.9.
§ I 50.0(k) I A:
Installed luminaires shall be classified as high -efficacy or low -efficacy for compliance with § 150.0(k) in accordance with TABLE
150.0-A or TABLE 150.0-B. as applicable.
§1 50.0(k)l B:
When a high efficacy and low efficacy lighting system are combined in a single luminaire, each system shall separately comply
with the applicable provisions of § I 50.0(k).
The wattage and classification of permanently installed luminaires in residential kitchens shall be determined in accordance with
§ I 50.0(k)] C:
§ 130.0(c). In residential kitchens, the wattage of electrical boxes finished with a blank cover or where no electrical equipment has
been installed, and where the electrical box can be used for a luminaire or a surface mounted ceiling fan, shall be calculated as 180
watts of low efficacy lighting per electrical box.
§ I 50.0(k) I D:
Ballasts for fluorescent lamps rated 13 watts or greater shall be electronic and shall have an output frequency no less than 20 kHz.
Permanently installed night lights and night lights integral to installed luminaires or exhaust fans shall be rated to consume no
§ I 50.0(k)] E:
more than 5 watts of power per luminaire or exhaust fan as determined in accordance with §1 30.0(c). Night lights do not need to
be controlled by vacancy sensors.
§ I 50.0(k) I F:
Lighting integral to exhaust fans (except when installed by the manufacturer in kitchen exhaust hoods) shall meet the applicable
requirements of § I 50.0(k).
§150.0(k)2A:
High efficacy luminaires must be switched separately from low efficacy luminaires.
§ I 50.0(k)2B:
Exhaust fans shall be switched separately from lighting systems.
§ I 50.0(k)2C:
Luminaires shall be switched with readily accessible controls that permit the luminaires to be manually switched ON and OFF.
§ I 50.0(k)2D:
Controls and equipment are installed in accordance with manufacturer's instructions.
§ I 50.0(k)2E:
No control shall bypass a dimmer or vacancy sensor function if the control is installed to comply with § I 50.0(k).
§ I 50.0(k)2F:
Lighting controls comply with applicable requirements of § 110.9.
An Energy Management Control System (EMCS) may be used to comply with dimmer requirements if. it functions as a dimmer
§ I 50.0(k)2G:
according to § 110.9; meets Installation Certificate requirements of § 130.4; the EMCS requirements of § 130.5: and all other
requirements in § I 50.0(k)2.
An Energy Management Control System (EMCS) may be used to comply with vacancy sensor requirements of § I 50.0(k) if: it
§150.0(k)2H:
functions as a vacancy sensor according to § 110.9; meets Installation Certificate requirements of §130.4; the EMCS requirements
of § 130.5 -, and all other requirements in § 150.0(k)2.
§ I 50.0(k)21:
A multiscene programmable controller may be used to comply with dimmer requirements of this section if it provides the
functionality of a dimmer according to § 110.9, and complies with all other applicable requirements in § I 50.0(k)2.
§ I 50.0(k)3A:
A minimum of 50 percent of the total rated wattage of permanently installed lighting in kitchens shall be high efficacy.
Kitchen lighting includes all permanently installed lighting in the kitchen except internal lighting in cabinets that illuminate only
§ I 50.0(k)3 B:
the inside of the cabinets. Lighting in areas adjacent to the kitchen, including but not limited to dining and nook areas, are
considered kitchen lighting if they are not separately switched from kitchen lighting.
§ I 50.0(k)4:
Permanently installed lighting that is internal to cabinets shall use no more than 20 watts of power per linear foot of illuminated
cabinet.
§150.0(k)5:
A minimum of one high efficacy huninaire shall be installed in each bathroom; and all other lighting installed in each bathroom
shall be high efficacy or controlled by vacancy sensors.
§ I 50.0(k)6:
Lighting installed in attached and detached garages, laundry rooms, and utility rooms shall be high efficacy luminaires and
controlled by vacancy sensors.
§ I 50.0(k)7:
Lighting installed in rooms or areas other than in kitchens, bathrooms, garages, laundry rooms, and utility rooms shall be high
efficacy, or shall be controlled by either dimmers or vacancy sensors.
Luminaires recessed into ceilings shall: be listed for zero clearance insulation contact (IC) by Underwriters Laboratories or other
nationally recognized testing/rating laboratory-, have a label that certifies that the luminaire is airtight with air leakage less than 2.0
CFM at 75 Pascals when tested in accordance with ASTM E283; be sealed with a gasket or caulk between the luminaire housing
§ I 50.0(k)8:
and ceiling, and shall have all air leak paths between conditioned and unconditioned spaces sealed with a gasket or caulk; and
allow ballast maintenance and replacement without requiring cutting holes in the ceiling.
For recessed compact fluorescent luminaries with ballasts to qualify as high efficacy for compliance with § I 50.0(k), the ballasts
shall be certified to the Energy Commission to comply with the applicable requirements in § 110.9.
For single-family residential buildings, outdoor lighting permanently mounted to a residential building or other buildings on the
same lot shall be high efficacy, or may be low efficacy if it meets all of the following requirements:
i. Controlled by a manual ON and OFF switch that does not override to ON the automatic actions of Items ii or iii below: and
§ I 50.0(k)9A:
ii. Controlled by a motion sensor not having an override or bypass switch that disables the motion sensor, or controlled by a
motion sensor having a temporary override switch which temporarily bypasses the motion sensing function and automatically
reactivates the motion sensor within 6 hours: and
iii. Controlled by one of the following methods:
I
2013 Low -Rise Residential Mandatory Measures Summary
a. Photocontrol not having an override or bypass switch that disables the photocontrol; or
b. Astronomical time clock not having an override or bypass switch that disables the astronomical time clock, and which is
programmed to automatically turn the outdoor lighting OFF during daylight hours; or
c. Energy management control system which meets all of the following requirements: At a minimum provides the functionality of
an astronomical time clock in accordance with § 110.9; meets the Installation Certification requirements in § 130.4; meets the
requirements for an EMCS in § 130.5; does not have an override or bypass switch that allows the luminaire to be always ON: and,
is programmed to automatically turn the outdoor lighting OFF during daylight hours.
For low-rise multifamily residential buildings, outdoor lighting for private patios,. entrances, balconies, and porches; and outdoor
lighting for residential parking lots and residential carports with less than eight vehicles per site shall comply with one of the
§ I 50.0(k)9B:
following requirements:
i. Shall comply with § I 50.0(k)9A; or
ii. Shall comply with the applicable requirements in § 110.9, § 130.0, § 130.2, § 130.4, § 140.7 and § 14 1.0.
§ I 50.0(k)9C:
For low-rise residential buildings with four or more dwelling units, outdoor lighting not regulated by § I 50.0(k)9B or 150.0(k)9D
shall comply with the applicable requirements in § 110.9, §130.0, § 130.2.
, §130.4, §140.7 and §141.0.
§ I 50.0(k)9D:
Outdoor lighting for residential parking lots and residential carports with a total of eight or more vehicles per site shall comply
with the applicable requirements in § 110.9, §130.0, § 130.2, § 130.4, § 140.7 and § 141.0.
§ I 50.0(k) 10:
Internally illuminated address signs shall comply with § 140.8; or shall consume no more than 5 watts of power as determined
according to § 130.0(c).
§ I 50.0(k) 11:
Lighting for residential parking garages for eight or more vehicles shall comply with the applicable requirements for
nonresidential garages in §110.9, §130.0, §130.1, §130.4t §140.6. and §141.0.
In a low-rise multifamily residential building where the total interior common area in a single building equals 20 percent or less of
§150.0(k)12A:
the floor area, permanently installed lighting for the interior common areas in that building shall be high efficacy luminaires or
controlled by an occupant sensor.
In a low-rise multifamily residential building where the total interior common area in a single building equals more than 20
percent of the floor area, permanently installed lighting in that building shall:
§ I 50.0(k) 1213:
i. Comply with the applicable requirements in § 110.9, § 130.0, §130. 1, § 140.6 and § 141.0; and
ii. Lighting installed in corridors and stairwells shall be controlled by occupant sensors that reduce the lighting power in each
space by at least 50 percent. The occupant sensors shall be capable of turning the light fully On and Off from all designed paths of
ingress and egress.
Solar Ready Buildings:
Single family residences located in subdivisions with ten or more single family residences and where the application for a
§110.1 0(a)l:
tentative subdivision map for the residences has been deemed complete, by the enforcement agency, on or after January 1, 2014,
shal I comply with the requirements of § I 10. 1 0(b) through § I 10. 1 O(e).
§ I 10. 1 0(a)2:
Low-rise multi -family buildings shall comply with the requirements of § I 10. 1 0(b) through § I 10. 1 0(d).
The solar zone shall have a minimum total area as described below. The solar zone shall comply with access, pathway, smoke
ventilation, and spacing requirements as specified in Title 24, Part 9 or other Parts of Title 24 or in any requirements adopted by a
local jurisdiction. The solar zone total area shall be comprised of areas that have no dimension less than 5 feet and are no less than
80 square feet each for buildings with roof areas less than or equal to 10,000 square feet or no less than 160 square feet each for
§ I 10. 1 0(b) 1:
buildings with roof areas greater than 10,000 square feet.
For single family residences the solar zone shall be located on the roof or overhang of the building and have a total area no less
than 250 square feet. For low-rise multi -family buildings the solar zone shall be located on the roof or overhang of the building or
on the roof or overhang of another structure located within 250 feet of the building or on covered parking installed with the
building project and have a total area no less than 15 percent of the total roof area of the building excluding any skylight area.
§ I 10. 1 0(b)2:
All sections of the solar zone located on steep -sloped roofs shall be oriented between I 10 degrees and 270 degrees of true north.
§ I 10. 1 0(b)3A:
No obstructions, including but not limited to, vents, chimneys, architectural features, and roof mounted equipment,
. shall be
located in the solar zone.
Any obstruction, located on the roof or any other part of the building that projects above a solar zone shall be located at least twice
§ I 10. 1 0(b)3B:
the distance, measured in the horizontal plane, of the height difference between the highest point of the obstruction and the
horizontal projection of the nearest point of the solar zone, measured in the vertical plane.
§ I 10. 1 0(b)4:
For areas of the roof designated as solar zone, the structural design loads for roof dead load and roof live load shall be clearly
indicated on the construction documents.
The construction documents shall indicate: a location for inverters and metering equipment and a pathway for routing of conduit
§ I 10. 1 0(c):
from the solar zone to the point of interconnection with the electrical service (for single family residences the point of
interconnection will be the main service panel); a pathway for routing of plumbing from the solar zone to the water -heating
system.
§ I 10. 1 0(d):
A copy of the construction documents or a comparable document indicating the information ftom § I 10. 1 0(b) through § I 10. 1 0(c)
shall be provided to the occupant.
§ I 10. 1 O(e) 1:
The main electrical service panel shall have a minimum busbar rating of 200 amps.
The main electrical service panel shall have a reserved space to allow for the installation of a double pole circuit breaker for a
§ I 10. 1 O(e)2:
future solar electric installation. The reserved space shall be: positioned at the opposite (load) end ftom the input feeder location or
main circuit location, and permanently marked as "For Future Solar Electric".
. . . . . . . . . .
. . . . .
. . . . . .
ago
NEI
I