13-0390 (AR)P.O. BOX 1504
78-495 CALLE TAMPICO . , V,
LA QUINTA, CALIFORNIA 92253 ..jp�
Application Number:
Property Address:
APN:
Application description:
Property Zoning:
Application valuation:
Applicant:
(•o�-1'tA-Ii�7l�L.
13-00000390-
81760 RUSTIC CANYON DR
764-280-999-82 -300237-
ADDITION - RESIDENTIAL
MEDIUM HIGH DENSITY REP.
11000
Architect or
1
BUILDING & SAFETY DEPARTMENT
BUILDING PERMIT
------------------
LICENSED CONTRACTOR'S DECLARATION
I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with
Section 70001 of Division 3 of the Business and Professionals Code, and my License is in full force and effect.
License Class: 13 License 96330
Date: Contractor.
OWNER-BUILDIR DECLARATION
hereby affirm under penalty of perjury that 1 am exempt from the Contractor's State License Law for the -
following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to
construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the
permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State
License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or
that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section -7031 .5 by
any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).:
( - ) I, as owner of'the property, or my employees with wages as their sole compensation, will do the work, and
the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The
Contractors' State License Law does not apply to an owner of property who builds or improves thereon, .
and who does the work himself or herself through his or her own employees, provided that the
improvements are not intended or offered for sale. If, however, the building or improvement is sold within
one year of completion, the owner -builder will have the burden of proving that he or she did not build or
improve for the purpose of sale.).
(_ 1 1, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec.
7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of
property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed
pursuant to the Contractors' State License Law.).
(_ I I am exempt under Sec. , BAP.C. for this reason -
Date:
Owner:
CONSTRUCTION LENDING AGENCY
I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the
work for which this permit is issued (Sec. 3097, Civ. C.).
Lender's Name:
Lender's Address:
LQPERMIT
VOICE (760) 777-7012
FAX (760) 777-7011
INSPECTIONS (760) 777-7153
Date: 4/24/13
Owner:
STILLMAN, RONALD & LORI
81760 RUSTIC CANYON
LA QUINTA, CA 92253
Contractor:
HUNT CONSTRUCTION SERVICES
PO BOX 116
PALM SPRINGS, CA 92263
(760)578-7153
Lic. No.: 963308
------------------
WORKER'S COMPENSATION DECLARATION
I hereby affirm under penalty of perjury one of the following declarations:
I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided
for by Section 3700 of the Labor Code, for the performance of the work for which this permit is
issued.
I have and will maintain'workers' compensation insurance, as required by Section 3700 of the Labor -
Code, for the performance of the work for which this permit is issued. My workers' compensation
�insurance carrier and policy number are:
Carrier EX-10GT. Policy Number EXEMPT
I certify that, in the performance of the work for which this permit is issued, I shall not employ any
person in any manner so as to become subject to the workers' compensation laws of California,
and agree that, if I should become subject to the workers' compensation provisions of Section
3700 of the Labor Code, I shall forthwith comply with those provisions.
Date: - Applicant:
WARNING:. FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL
SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND
DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN
SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES.
APPLICANT ACKNOWLEDGEMENT
IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the
conditions and restrictions set forth on this application. .
1., Each person upon whose behalf this application is made, each person at whose request and for
whose benefit work is performed under or pursuant to any permit issued as a result of this application,
the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City
of La Quinta, its officers, agents and employees for any act or omission related to the work being
performed under or following issuance of this permit.
2. Any permit issued as a result of this application becomes null and void if work is not commenced
within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject
permit to cancellation:
I certify that I have read this application and state that the above information is correct. I agree to comply with all
city and county ordinances and state laws relating to building construction, and hereby authorize representatives
of this county to enter upon the above-mentioned property for inspection purposes.
Signature (Applicant or Agent):
LQPERMIT
Application Number . . . . . 13-0.0000390
------ Structure Information 92SF PATIO CONVERSION/VB/RES-3
[ENG] -----
Other struct info CODE EDITION
2010
FLOOD ZONE
NO
1ST FLOOR SQUARE;FOOTAGE
----------------------------------------------------------------------------
92.00
Permit . . . BUILDING.PERMIT
Additional desc .
Permit Fee . . . . 126.00 Plan Check Fee
81.90
Iooue Datc . . . . ValuaLion . . .
. 11000
Expiration Date 10/21/13
Qty Unit Charge Per
Extension
BASE FEE
45.00
9.00 9.0000 THOU BLDG 2,001-25,000
----------------------------------------------------------------------------
81.00
Permit . . . ELECT - ADD/ALT/REM
Additional desc .
Permit Fee . . 18.22 Plan Check Fee
4.56
Issue Date. Valuation . . .
. 0
Expiration Date 10/21/13
Qty Unit Charge Per
Extension
BASE FEE
15.00
92.00 .0350 ELEC NEW RES - 1 OR 2 FAMILY
----------------------------------------------------------------------------
3.22
Permit . . . MECHANICAL
Additional desc .
Permit Fee . . . . 19.50 Plan Check Fee
4.88
Issue Date . . . . Valuation
0
Expiration Date 10/21/13
Qty Unit Charge Per
Extension
BASE FEE
15.00
1.00 4.5000 EA MECH VENT INST/ DUCT ALT
4.50
--------------------------------------=-------------------------
Special Notes and Comments
------------
92SF PATIO CONVERSION TO'CLOSET SPACE
(ENGINEERED] THIS PERMIT DOES NOT
INCLUDE ADDITION TO EXISTING•BUILDING
FOOTPRINT. 2010 CALIFORNIA BUILDING
CODES.
April 24, 2013 3:20:56 PM AORTEGA
-
------------------------------------------------------------ ----------------
Other Fees . . . . . BLDG STDS ADMIN (SB1473)
1.00
LQPERMIT
Application Number
. . . . .
13-00000390
Other Fees .
. . . . . .
ENERGY REVIEW FEE
8.19
STRONG MOTION (SMI).- RES
1.,10
Fee summary
Charged
Paid Credited
Due
Permit Fee Total
163.72
.00 .00
163.72
Plan Check Total
91.34
.00 .00
91.34
Other Fee Total
10.29
00 .00
10.29
Grand Total
265.35
.00 .00
265.35
ern.# G
1
Cit}/ Of b Quitltd
But/ding 8r Safety Division
P.O. Box 1504,78-495 Calle Tampico
La.Quinta, CA 92253 - (760) 777-7012
Building Permit Application'and Tracking Sheet
Permit #
Project Address:
Owner's Name:. i� d L -O 7 i 4 % �. I t� Iy
A P. Number.
}�
Address: $ �o V U .L t C "�A 0
Legal Descri tion:
S P
Contractor: 9Uak C�`j e S�, (/ C
City, ST, Zip: L A U* ;�A, � /} ,� - �, 5,3
(� H
Telephone:
Address:
Project Description:
City, p: ; � �
Ci ST, Zi C i c' �`1f e- � di 4 e • —e cr
Telephone: �� G ^ J� i J3 ` `gor
a
®
State Lic. # : 3/�® p
Arch., Engr., Designer. S f (qt � �y
//Z p�
Address: T 4 0 1, ,, i Q
City., ST, Zip: i j • �h
Telephone: ,bD- ' — Construction Type �ccupancy:
State Lic. #: Project type (circle one): New Add'n alter- Repair Demo
Name of Contact Person: Sq. Ft : ! O� f a # Stories:
Telephone # of Contact Person: Estimated Value of Project:
APPLICANT: DO NOT WRITE BELOW THIS LINE
#
Submittal
Req'd
Rec'd
TRACMG
PERM T FEES
Plan Sets
Plan Check submitted 1{
�`
Item Amount
Structural Cates.
Reviewed, ready for corrections
Plan Check Deposit. .
Truss Calcs.
Called Contact Person 4R
Plan Check Sal ince
Title 24 Cates.
2.
Plans picked up
Constmedon
Flood plain plan
Plans resubmitted...
Mechanical
Grading plan
2"! Review, ready for correctio a
Electrical
Subcoutactor List .
Called Contact Person
Plumbing
Grant Deed
Plans picked up
S.M.L
H.O.A. Approval
Plans resubmitted
Grading
IN HOUSE:-
'`° Review, ready for correedons/issae
Developer Impact Fee
Planning Approval
Called Contact Person
A.I.P.P.
Pub. Wks. Appr
Date of permit issue
School Fees
Total Permit Sees
UAW
M* ft ass
Coachella Valley Unified School District
83-:733 Avenue 55, Thermal, CA 92274
(760) 398-5909 — Fax (760) 398-1224
This Box For District Use Only
DF.
EVLOPFIZ FEES PAID
AREA: .. .. .. ..
AMOUNT, . .. .. ..
LEVELONEAMOUNT:
LEVEL TWO AMOUNT:
MIT'GATION AMOUNT:
COMM IND. AMOUNT:
DATE:
RECEIPT:
CHECKH:
INITIALS
CERTIFICATE OF COMPLIANCE
(California Education Code 17620)
Project Name: T'd7ald,8i LoriiShlhnan Date: April 29, 2013
Owner's Name: Phone No.
Project Address: 81-760 Rustic Canyon; La Quintal CA
Project Description: Patio Conversion
APN: 764-280-999-82 Tract #: Lot #'s:
Type of Development: Residential XX Commercial Industrial
Total Square Feet of Building Area: 92. .
Certification of Applicant/Owners: • The person signing certifies that IM above information is correct and makes this statement under
penalty of perjury and further represents that he/she is authorized to sign on behalf of the owner/develo-jer.
Dated:
o
SCHOOL DISTRICT'S REQUIREMENTS FOR THE ABOVE PROJECT HAVE BEEN OR WILL BE SATISFIED IN':
ACCORDANCE WITH ONE OF THE FOLLOWING: (CIRCLE ONE)
Education Code Gov. Code Project
17620 65995 Approval
Number of Sq.Ft. 92
Amount per Sq.Ft. EXEMPT
Amount Collected 0.00
Building Permit Application Completed: Yes/No
By: Elsa F. Esqueda, Director of Facilities and:Maintenance
Certificate issued by: Leticia Torres, Facilities Analyst
NOTICE OF 90 DAY PERIOD ]
Agreement Existing Not.Subject to Fee
Prior to 1/1/87 Requirement
il�lote:
Pursuant to AB 181 any room additions or enclosures of 500
s.f. or less are exempt from dev--loper fees. Any mobile homes
being relocated within the same school district's jurisdiction
are exempt from developer fees.
Section 66020 of the Government Code asserted by, Assembly Bill 3081, effective January;l, 1997, requires that-�District provide (1) a written, notice to the
project appellant, at the time of payment of school fees, mitigation payment or other exactions ("Fees".), of the 90 -day period to protest the imposition of these
Fees and (2) the amount of the fees. Therefore, in accordance with section 66020 of the Government code and other aiplicable law, this Notice shall serve to
advise you that the 90 -day protest period in regard. to such Fees or the validity thereof, commences with the payment of the fees or performance of any other
requirements as described in section 66020 of the Government code. Additionally, the amount of the fees imposed is as ierein set forth, whether payable at this
time or in whole.or in part prior to issuance of a Certificate of Occupancy. As in the latter, the 90 days starts of the date hereof. This Certificate of
Compliance is valid for thirty (30) days from the date of issuance. Extension will be granted only for good cause, as desermiried by the School District, and up
to three (3) such extensions may be granted.
N1 V:G mvdocs1de%'fees/certi11C.Ite of compliance Perm Updaltd 3-2007 11/2010
.0
C�4
Trflogv
A
March 28, 2013
Ronald Stillman '
Lori Stillman
81760 Rustic Canyon Dr
La Quinta, CA 92253
Property: 81760 Rustic Canyon Dr
Account: 015000020881
CONDITIONAL APPROVAL
Dear Ronald Stillman:
We are pleased to'inform you that your plans for enclosing.the_small_patio-ar-ea..and convert it as .part of the
living area/home, received on 03/12/2013, have been approved by the Design Review Committee with, the
following conditions: 7, 8, 9, 19 and 23. • This submittal does not address landscaping or stucco
color/texture. The owner may proceed with the acknowledgement that impacted landscaping, stucco
and stucco color will conform with the TLQMA Design Guidelines (see attached copy).
Please note: Any damages caused by contractor due to construction must be repaired; all irrigation
and landscape shall be restored to original condition.
This approval does not constitute consent by the Association for the applicant to encroach, trespass, or
build on any property other than that of the applicant. This approval is related solely to the items reserved
for approval by the CC&R's in accordance with the Design Review Guidelines. The approval does 'not
extend to the quality of work done by your architect, or contractor, or to any, structural engineering, soils
engineering, or site grading and drainage design. You are urged to obtain the services of a state licensed
professional for consultation as needed: ,
The Design Review .Committee is composed of volunteers. As such, it does not review applications to
ensure compliance with building codes, or other local or state 1'aws..Please be advised that this approval
does not relieve you from obtaining any necessary building permits from the governmental agencies
involved to ensure compliance with these codes. Any violations of these ordinances will be your
responsibility to correct. Thank you for your patience in this matter and for complying with the
Association's policies and standards.
Sincely,
For_ aign��ieCommittee
r
Barry Stere ' CCAM, CMCA, AMS
General Mlager -
Enclosures
cc: Board of Directors
Design Review Committee
Trilogy at La Quinta MAintenance Assoc.
Professionally Managed by Action Properly Management. Inc.
60-750 Trilogy Parkway, LaQuinta, CA 92253-7717
Phone: 760-777-6059 Fax: (760) 564-2474
www.actionlife.com
BUILDING ENERGY ANALYSIS REPORT '
PROJECT:
F Stillman Residence Addition
81=760 Rustic Canyon Drive
La Quinta, CA 92253
Project Designer: ,.
Hunt Construction Services
P.O:. Box 1.16
Palm Springs, CA 92263
(760) 578-7153
Report Prepared by:
Tim Scott
Scott Design and Title 24, Inc,
77-085 Michigan Driv
Palm, Desert, Ca 9221 CITE' OrLA QUINTA
(7 60) 200-4780 BUILDING & SAFETY DEPT.
APPROVED,,,
FOR CONSTRUCTION
DATE BY
• Job Number:REGEIVE®
Date: APR 0 12013
4/1/2013 CITY OF LA QUINTA .
COMMUNITY DEVELOPMENT
The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is �.
authorized by the California Energy Commission for use with both the Residential and Nonresidential 2008 Building Energy Efficiency Standards.
This program developed by EnergySoft, LLC — www.energysoft.com.
EnergyPro 5.1 by EnergySft User Number: 6712 RunCode: 2013-04-01720:10:46 ID:
. _ x
.i �
< ..
7
. t
PERFORMANCE CERTIFICATE: Residential Part 1 of 5
CF -1 R
Project Name
Stillman Residence Addition
Building Type m Single Family ❑ Addition Alone
❑ Multi Family m Existing+ Addition/alteration
Date
4/1/2013
`Project Address
81-760 Rustic Canyon Drive La Quinta
California Energy Climate Zone
CA Climate Zone 15
Total Cond. Floor Area
92
Addition
92
# of Stories
1
FIELD INSPECTION ENERGY CHECKLIST
❑ Yes ❑ No � HERS Measures -- If Yes, A CF -4R must be provided per Part 2 of 5 of this form.
❑ Yes ❑ No Special Features -- If Yes, see Part 2 of 5 of this form for details.
INSULATION Area Special
Construction Type Cavity Features see Part 2 of 5 Status
Roof Wood Framed Attic R-30 92 Radiant Barrier New
Wall Wood Framed R-19 152 New
Slab Unheated Slab -on -Grade None 92 Perim = 20' New
FENESTRATION U- Exterior
Orientation Area Factor SHGC Overhang Sidefins Shades Status
Rear (M 40.0 0.710 0.73 none none Bug Screen
Removed
Rear (tM 6.0 0.520 0.29 none none Bug Screen
New
HVAC SYSTEMS
Ot . Heating Min. Eff Cooling Min. Eff Thermostat Status
1 Central Furnace 60% AFUE Split Air Conditioner 13.0 SEER Setback
Existing
HVAC DISTRIBUTION Duct
Location Heating Cooling Duct Location R -Value
Status
HVAC- Ducted Ducted Attic, Ceiling Ins, vented 4.:
Existing
WATER HEATING
Ot . Type Gallons Min. Eff Distribution
Status
EnergyPro 5.1 by Ener Soft User Number: 6712 Run Code: 2013-04-01T20:10:46 ID:
Page 3 of 10
PERFORMANCE CERTIFICATE: Residential Part 2 of 5) CF -1 R
Project Name
Stillman Residence Addition
Building Type ® Single Family ❑ Addition Alone
❑ Multi Family m Existing+ Addition!Alteration
Date
4/1/2013
SPECIAL FEATURES INSPECTION CHECKLIST
The enforcement agency should pay special attention to the items specified in this checklist. These items require special written
justification and documentation, and special verification to be used with the performance approach. The enforcement agency
determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of
the special justification and documentation submitted.
The Roof R-30 Roof(R.30.2x 12.16) includes credit for a Radiant Barrier that is Continuous meeting eligibility and installation criteria as specified in
Residential Appendix RA4.2.2.
HERS REQUIRED VERIFICATION
Items in this section require field testing and/or verification by a certified HERS Rater. The inspector must receive a
completed CF -4R form for each of the measures listed below for final to be given.
Ene Pro 5.1 b Ene Soft User Number. 6712 RunCode: 2013-04-01720:10:46 /D: Page 4 of 10
PERFORMANCE CERTIFICATE: Residential (Part 3 of 5) CF-1 R
Project Name
Building Type m Single Family ❑ Addition Alone
Date
Stillman Residence Addition
❑ Multi Family m Existing+ Addition/Alteration
4/1/2013
ANNUAL ENERGY USE SUMMARY
Standard Proposed Margin
TDV kBtu/ft2- r
Space Heating 2.13 0.05 2.08
Space Cooling 218.30 211.46 6.83
Fans 53.12 51.90 1.21 t
Domestic Hot Water 205.28 205.28 0.00
Pumps 0.00 0.00 0.00
Totals 478.82 468.70 10.12
Percent Better Than Standard: 2.10
BUILDING COMPLIES - NO HERS VERIFICATION REQUIRED
Fenestration
Building Front Orientation: (E) 90 deg Ext. Walls/Roof Wall Area Area
Number of Dwelling Units: 1.00 (E) 0 0
Fuel Available at Site: Natural Gas (S) 60 0
Raised Floor Area: 0 (tM 98 6
Slab on Grade Area: 92 (N) 0 0
Average Ceiling Height: 8.0 Roof 92 0
Fenestration Average U-Factor: 0.52 TOTAL: 6
Average SHGC: 0.29 Fenestration/CFA Ratio: 6.5%
REMARKS
STATEMENT OF COMPLIANCE
This certificate of compliance lists the building features and specifications needed
to comply with Title 24, Parts 1 the Administrative Regulations and Part 6 the
Efficiency Standards of the California Code of Regulations.
The documentation author hereby certifies that the documentation is accurate and complet .
Documentation Author
Company Scott Design and Title 24, Inc,
4/1/2013
Address 77-085 Michigan Drive Name Tim Scott
City/State/ZipCity/State/Zip Palm Desert, Ca 92211 Phone (760) 200-4780 Signed Date
The individual with overall design responsibility hereby certifies that the proposed building design represented in this set
of construction documents is consistent with the other compliance forms and worksheets, with the specifications, and
with any other calculations submitted with this permit application, and recognizes that compliance using duct design,
duct sealing, verification of refrigerant charge, insulation installation quality, and building envelope sealing require
installer testing and certification and field verification by an approved HERS rater.
Designer or Owner.(per Business & Professions Code)
Company Hunt Construction Services
Address P.O. Box 116 Name Hark Hunt
City/State/Zip Palm Springs, CA 92263 Phone (760) 578-7153 Signed License # Date
Ener Pro 5.1 by EnerqySoft User Number: 6712 RunCode: 2013-04-01720:10:46 ID: Page 5 of 10
CERTIFICATE OF COMPLIANCE: Residential Part 4 of 5 CF -1 R
Project Name
Stillman Residence Addition
Building Type m Single Family ❑ Addition Alone
El Multi Family m Existing+ Additioi/Alteration
Date
4/1/2013
OPAQUE SURFACE DETAILS
Surface U- Insulation Joint Appendix
Type Area Factor Cavity Exterior Frame Interior Frame Azm Tilt Status 4 Location/Comments
Roof, 92 0.032 0-30 0 0 New 4.2.1-A8 Addition
Wall 60 0.074R-19 180 90 1 New 4.3.1-A5 Addition
Wall 58 0.074 R-19 270 90 Remove 4.3.1-A5 Addition
Wall1 92 0.074 R-19 270 90 New 4.3.1-A5 Addition
Slab 92 0.730 None 0 180 New 4.4.7-A1 Addition
FENESTRATION SURFACE DETAILS
Type Area U -Factor SHGC Azm Status GlazingType Location/Comments
1 Window 40.0 0.710 Default 0.73 1 Default 270 Removed Double Metal Window addition
F2ID
Window 6.0 0.520 NFRC 0.29 NFRC 270 New Double Metal Tinted _addition
(1) U -Factor Type: 116-A = Default Table from Standards, NFRC = Labeled Value
2 SHGC Type: 116-13 = Default Table from Standards, NFRC = Labeled Value
EXTERIOR SHADING DETAILS
Window Ove hanq Left Fin Ri ht Fin
ID Exterior Shade Type SHGC Hot Wd Len Hot LExt RExt Dist Len I H t Dist Len Hot
1 Bug Screen 0.76
2 Bug Screen 0.76
Ener Pro 5.1 by Ener Soft User Number: 6712 RunCode: 2013-04-01720:10:46 ID: Page 6 of 10
CERTIFICATE OF COMPLIANCE: Residential (Part 5 of 5)
CF -1 R
Project Name
Stillman Residence Addition
Building Type ® Single Family ❑ Addition Alone
❑ Multi Family m Existing+ Addition/Alteration
Date
4/1/2013
BUILDING ZONE INFORMATION
System Name Zone Name
Floor Area ft
New Exis - ting A tered Removed Volume Year Built
HVAC- Addition
92
736
Totals 921 01 01 01
1
HVAC SYSTEMS
System Name Qty. Heating Type
Min. Eff. Cooling Type Min. Eff. Thermostat Type Status
HVAC 1 Central Furnace
80% AFUE Split Air Conditioner 13.0 SEER Setback
Existing
HVAC DISTRIBUTION
System Name Heating
Duct
Cooling Duct Location R -Value
Ducts
Tested? Status
HVAC- Ducted
Ducted Attic, Ceiling Ins, vented 4.2
❑ Existing
WATER HEATING SYSTEMS
S stem Name
Qty.
Type
Distribution
Rated
Input
Btuh
Tank
Cap.
al
Energy
Factor
or RE
Standby
Loss or
Pilot
Ext.
Tank
Insul. R-
Value
Status
Standard 50 gal or Less
1
Small Gas
All Pipes Ins
40,000
50
0.59
n/a
n/a
Existing
MULTI -FAMILY WATER
HEATING
DETAILS
HYDRONIC
HEATING SYSTEM
PIPING
Control
Hot Water Piping Length
(ft)
o
iii
n
a
System Name
Pipe
Lena th
Pipe
Diameter
Insul.
Thick.
Qty. HP
Plenum Outside Buried
❑
Ener Pro 5.1 by EnergySoft User Number: 6712
RunCode: 2013-04-01720:10:46 ID:
Pae 7 of 10
MANDATORY MEASURES SUMMARY: Residential Pae 1 of 3 MF -1 R
Project Name
Stillman Residence Addition
Date
4/1/2013
NOTE: Low-rise residential buildings subject to the Standards must comply with all applicable mandatory measures listed, regardless of
the compliance approach used. More stringent energy measures listed on the Certificate of Compliance (CF -1 R, CF -1 R -ADD, or CF -
1 R -ALT Form) shall supersede the items marked with an asterisk (') below. This Mandatory Measures SumrT ary shall be incorporated
into the permit documents, and the applicable features shall be considered by all parties as minimum component performance
specifications whether they are shown elsewhere in the documents or in this summary. Submit all applicable sections of the MF -1 R
Form with plans.
Building Envelope Measures:
116(a)l: Doors and windows between conditioned and unconditioned spaces are manufactured to limit air leakage.
§116(a)4: Fenestration products (except field -fabricated windows) have a label listing the certified LI -Factor, certified Solar Heat Gain
Coefficient SHGC , and infiltration that meets the re uirements of 10-111 (a).
117: Exterior doors and windows are weather-stripped; all joints and penetrations are caulked and sealed.
118(a): Insulationspecified or installed meets Standards for Insulating Material. Indicate type and include on CF -6R Form.
[§118(i): The thermal emittance and solar reflectance values of the cool roofing material meets the requirements of §118(i) when the
installation of a Cool Roof is specified on the CF -1 R Form.
*§1 50 a : Minimum R-19 insulation in wood -frame ceiling orequivalent Ll -factor.
§150(b): Loose fill insulation shall conform with manufacturer's installed design labeled R -Value.
*§150(c): Minimum R-13 insulation in wood -frame wall orequivalent Ll -factor.
*§15 0 d : Minimum R-13 insulation in raised wood -frame floor orequivalent Ll-factor.
150 (f): Air retarding wrap is tested labeled and installed according to ASTM E1677-95 2000 when specified on the CF -1 R Form.
4150(g): Mandatory Vapor barrier installed in Climate Zones 14 or 16.
§150(1): Water absorption rate for slab edge insulation material alone without facings is no greater than 0.3%; water vapor permeance
rate is no greater than 2.0perm/inch and shall be protected from physical damage and UV light deterioration
Fireplaces, Decorative Gas Appliances and Gas Log Measures:
150 e 1 A: Masonry or facto -built fireplaces have a closable metal or glass door covering the entire opening of the firebox.
§150(e)1 B: Masonry or factory -built fireplaces have a combustion outside air intake, which is at least six square inches in area and is
Lequipped with a with a readily accessible, operable, and tight -fitting damper and or a combustion -air control device.
§150(e)2: Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the
outside of the building, are prohibited.
Space Conditioning, Water Heating and Plumbing System Measures:
§110-§113: HVAC equipment, water heaters, showerheads, faucets and all other regulated appliances are certified by the Energy
Commission.
§113(c)5: Water heating recirculation loops serving multiple dwelling units and High -Rise residential occupaicies meet the air release
valve, backflow prevention, pump isolation valve, and recirculation loop connection requirements of §113(c)5.
§115: Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces, household cooking appliances
(appliances with an electrical supply voltage connection with pilot lights that consume less than 150 Btu/hr are exempt), and pool and
spa heaters.
150(h): Heating and/or cooling loads are calculated in accordance with ASHRAE, SMACNA or ACCA.
Heating systems are equipped with thermostats that meet the setback requirements of Section 112 c).
,§150(i):
§1500)1 A: Storage gas water heaters rated with an Energy Factor no greater than the federal minimal stancard are externally wrapped
with insulation having an installed thermal resistance of R-12 or greater.
§150(j)1 B: Unfired storage tanks, such as storage tanks or backup tanks for solar water -heating system, or Ether indirect hot water
'tanks have R-12 external insulation or R-16 internal insulation where the internal insulation R -value is indicated on the exterior of the
tank.
'§1 50(j)2: First 5 feet of hot and cold water pipes closest to water heater tank, non -recirculating systems, and entire length of
recirculating sections of hot water pipes are insulated per Standards Table 150-13.
§150(j)2: Cooling system piping (suction, chilled water, or brine lines),and piping insulated between heating: source and indirect hot
water tank shall be insulated to Table 150-B and Equation 150-A.
§150(j)2: Pipe insulation for steam hydronic heating systems or hot water systems >15 psi, meets the requi -ements of Standards Table
123-A.
150(j)3A: Insulation is protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind.
§150(j)3A: Insulation for chilled water piping and refrigerant suction lines includes a vapor retardant or is enclosed entirely in
conditioned space.
§150(6)4: Solar water -heating systems and/or collectors are certified by the Solar Rating and Certification Corporation.
EnergyPro 5.1 by EnergySoR User Number: 6712 RunCode: 2013-04-01T20:10:46 ID: Page 8 of 10
F
r
•+
Date
Stillman Residence Addition
.-41112013
� r
§150(m)1: All air -distribution system ducts and plenums installed, are sealed and insulated to meet the requirements of CMC Sections
601, 602, 603,.604, 605 and Standard 6-5; supply -air and return -air ducts and plenums are insulated to a minimum installed level of R-
4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct -closure system that meets the
applicable requirements of.UL 181, UL 181 A, or UL 181 B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is
MANDATORY MEASURES SUMMARY: Residential (Page 2 of 3 MF -1 R
Project Name _
Date
Stillman Residence Addition
.-41112013
� r
§150(m)1: All air -distribution system ducts and plenums installed, are sealed and insulated to meet the requirements of CMC Sections
601, 602, 603,.604, 605 and Standard 6-5; supply -air and return -air ducts and plenums are insulated to a minimum installed level of R-
4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct -closure system that meets the
applicable requirements of.UL 181, UL 181 A, or UL 181 B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is
used to seal openings reater than 1/4 inch, the combination of mastic and either mesh or tape shall be used
§150(m)1: Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed
sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may
contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area
of the ducts: -
'•§150(m)2D: Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes
„unless such tape is used in combination with mastic and draw bands.
4150(m)7: Exhaust fans stems have back draft or automatic dampers.
§150(m)8: Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated
dampers.' . '
§150(m)9: Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind.
Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar
radiation that can cause'de radation of the material.
4150(m)10: Flexible ducts cannot have porous inner cores.
§150(6): All dwelling units shall meet the requirements of ANSI/ASHRAE Standard 62.2-2007 Ventilation and Acceptable Indoor Air
Quality in Low -Rise Residential Buildings. Window operation is not a permissible method of providing the Whole Building Ventilation
required in Section.4 of that Standard.
Pool and Spa'Heating Systems and Equipment Measures: `
§114(a): Any pool or spa heating system shall be certified to have: a thermal efficiency that complies with the Appliance Efficiency
Regulations; an on-off switch mounted outside of the heater; a permanent weatherproof plate or card with operating instructions; and
shall not use electric resistance heating ora pilot light. r
,,§114(b)1: Any pool or spa heating equipment shall be installed with at least 36" of pipe between filter and heater, or dedicated suction
and return lines, or built-up connections for future solar heating.
114(b)2: Outdoor pools ors as that have a heat pump or gas heater shall have a cover.
§114(b)3: Pools shall have directional 'inlets that adequately mix the pool water, and a time switch that will allow all pumps to be set or
programmed to run only during off-peak electric demand periods.
150 : Residential pool systems or equil5ment meet the pump sizing, flow rate, piping, filters, and valve requirements of 150
Residential, Lighting Measures: r
§150(k)1: High efficacy luminaires or LED Light Engine with Integral Heat Sink has an efficacy that is no lower than the efficacies
contained in Table 150-C and is not a low efficacy luminaire asspecified by §150(k)2.
150(k)3: The wattage of permanently installed luminaires shall be determined asspecified by §130(d).
§150(k)4: Ballasts for fluorescent lamps rated 13 Watts or greater shall be electronic and shall have an output frequency no less than
20 kHz.
'§1 50(k)5: Permanently installed night lights and night lights integral to a permanently installed luminaire or exhaust fan shall contain
only high efficacy lamps meeting the minimum efficacies contained in Table 150-C and shall not contain a line -voltage socket or line -
voltage lamp holder; OR shall be rated to consume no more than five watts of power as determined by §130(d), and shall not contain a
,medium screw -base socket.
'.§l 50 k 6: Lighting integral to exhaust fans, in rooms other than kitchens, shall meet t.he aRplicable requirements of 5150(k.). -
150(k)7: All switching devices and controls shall meet the requirements of §150(k)7.
§150(k)8: A minimum of'50 percent of the total rated wattage of permanently installed lighting in kitchens shall be high efficacy.
EXCEPTION: Up to 50 watts for dwelling units less than or equal to 2,500 ftz or 100 watts for dwelling units larger than 2,500 fiz maybe
exempt from the 50% high efficacy requirement when: all low efficacy luminaires in the kitchen are controlled by a manual on occupant
sensor, dimmer, energy management system (EMCS), or a multi -scene programmable control system; and all permanently installed
luminaries in garages, laundry rooms, closets greater than 70 square feet, and utility rooms are high efficacy and controlled by a
manual -on occupant sensor.'
§150(k)9: Permanently installed lighting that is internal to cabinets shall use no more than 20 watts of power per linear foot of
illuminated cabinet. '
EnergyPro 5.1 by EnergySoR User Number: 6712 RunCode: 2013-04-01T20:10:46 /D: Page 9 of 10
r
i
� r
r
MANDATORY MEASURES SUMMARY: Residential (Page 3 Y 3 MF -1 R
Project Name
Date
Stillman Residence Addition
4/1/2013
§150(k)10: Permanently installed luminaires in bathrooms, attached and detached garages, laundry rooms, closets and utility rooms
shall be high efficacy.
EXCEPTION 1: Permanently installed low efficacy luminaires shall be allowed provided that they are controlled by a manual -on
occupant sensor certified to comply with the applicable requirements of §119.
EXCEPTION 2: Permanently installed low efficacy luminaires in closets less than 70 square feet are not required to be controlled by a
manual -on occupancy sensor.
§150(k)l 1: Permanently installed luminaires located in rooms or areas other than in kitchens, bathrooms, garages, laundry rooms,
closets, and utility rooms shall be high efficacy luimnaires. EXCEPTION 1: Permanently installed low efficacy luminaires shall be
allowed provided they are controlled by either a dimmer switch that complies with the applicable requirement of §119, or by a manual -
occupant sensor that complies with the applicable requirements of §119. EXCEPTION 2: Lighting in detached storage building less
,on
than 1000 square feet located on a residential site is not required to comply with §150 k 11:
§150(k)l2`. Luminaires recessed into insulated ceilings shall be listed for zero clearance insulation contact (IC) by Underwriters
laboratory; and have a label that certifies the lumiuraire is airtight with air
Laboratories or other nationally recognized testing/rating
leakage less then 2.0 CFM at 75 Pascals when tested in accordance with ASTM E283; and be sealed with a gasket or caulk between
the luminaire housing and ceiling.
§150(k)l3: Luminaires providing outdoor lighting, including lighting for private patios in low-rise residential Wildings with four or more
dwelling units, entrances, balconies, and porches, which are permanently mounted to a residential building or to other buildings on the
same lot shall be high efficacy. EXCEPTION 1: Permanently installed outdoor low efficacy luminaires shall be allowed provided that
they are controlled by a manual on/off switch, a motion sensor not having an override or bypass switch that c:isables the motion sensor,
and one of the following controls: a photocontrol not having an override or bypass switch that disables the photocontrol; OR an
astronomical time clock not having an override or bypass switch that disables the astronomical time clock; OR, an energy management
control system (EMCS) not having an override or bypass switch that allows the luminaire to be always on EXCEPTION 2: Outdoor
luminaires used to comply with Exceptionl to §150(k)13 may be controlled by a temporary override switch which bypasses the motion
sensing function provided that the motion sensor is automatically reactivated within six hours. EXCEPTION 3: Permanently installed
luminaires in or around swimming pool, water features, or other location subject to Article 680 of the California Electric Code need not
be high efficacy luminaires.
§150(k)14: Internally illuminated address signs shall comply with Section 148; OR not contain a screw -base socket, and consume no
more than five watts of power as determined according to §130(d).
§150(k)15: Lighting for parking lots and carports with a total of for 8 or more vehicles per site shall comply wth the applicable
requirements in Sections 130, 132, 134, and 147. Lighting for parking garages for 8 or more vehicles shall comply with the applicable
requirements of Sections 130, 131, 134, and 146.
§150(k)l6: Permanently installed lighting in the enclosed, non -dwelling spaces of low-rise residential buildings with four or more
dwelling units shall be high efficacy luminaires. EXCEPTION: Permanently installed low efficacy luminaires shall be allowed provided
that they are controlled by an occupant sensors certified to comply with the applicable requirements of 119.
5 - '
EnergyPro 5.1 by EnergySoft User Number: 6712 RunCode: 2013-04-01720:10:46 ID: Page 10 of 10