Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
BSOL2015-0047
LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, and my License is in full force and effect. License Class: C46, B. C10, A License No.: 888104 Date: - Contractor:�� OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed. statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: (_) I, as owner of the property, or.my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building•or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). ( 11, as owner of the property, am exclusively contracting with licensed contractors to construct the project. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). I. ) I am exempt under Sec. B.&P.C. for this reason Date: Owner: . CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Lender's Address: WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: 6 1 have and will maintain a certificate :)f consent to self -insure for workers' compensation, as provided for by Section 3700 & the Labor Code, for the performance of the wo r which this permit is issued. I have and will maintain workers' conpehsation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and -policy number are: Carrier: _ Policy Number: I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so a: to become subject to the workers' compensation laws of California, and agree that if I should become subject to the workers' compensation provisions of Section 37)0 of the Labor Code, l shall forthwith comply with those provisions. Date: / /lam Applicant: �� n WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000;. IN ADDITION TO THE COST OF COMPENSATION,, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND'ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT: Application is hereby made to the 3uilding Official for a permit subject to the conditions and restrictions set forth on this application. 1.Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application , the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the C-ty of La Quinta, its officers, agents, and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is . not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinEnces and state laws relating to building construction, and hereby authorize representati .,es of thiscity to enter up theabove. mentioned pr p/erty for inspection purposes. Date: r/ Signature (Applicant o T VOICE (760) 777-7125 78-495 CALLE TAMPICO ' D6 FAX (760) 777-7011 LA QUINTA, CALIFORNIA 92253 COMMUNITY DEVELOPMENT DEPARTMENT INSPECTIONS (760) 777-7153 BUILDING PERMIT Dater 4/16/2015 Application Number: BSOL201S-0047 Owner: Property Address: 81820 RUSTIC CANYON DR JULI CONWAY APN: 764550034 844 CREEKSIDE DR-SE7F!1 Application Description: ALLISON/(16)ROOF MOUNTED PANELS (1)INVERTER SALEM, OR 92253 Property Zoning:Application Valuation: $9,193.00Applicant: Contractor: o SOLARCITY CORPORATION SOLARCITY CORPORATION w C) 3055 CLEARVIEW WAY 3055 CLEARVIEW WAY U. ATTN ZOE STEELE ATTN ZOE STEELE Q SAN MATEO, CA 94402 SAN MATEO, CA 94402 (650)963-5630 Llc. No.: 888104 LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, and my License is in full force and effect. License Class: C46, B. C10, A License No.: 888104 Date: - Contractor:�� OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed. statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: (_) I, as owner of the property, or.my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building•or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). ( 11, as owner of the property, am exclusively contracting with licensed contractors to construct the project. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). I. ) I am exempt under Sec. B.&P.C. for this reason Date: Owner: . CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Lender's Address: WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: 6 1 have and will maintain a certificate :)f consent to self -insure for workers' compensation, as provided for by Section 3700 & the Labor Code, for the performance of the wo r which this permit is issued. I have and will maintain workers' conpehsation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and -policy number are: Carrier: _ Policy Number: I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so a: to become subject to the workers' compensation laws of California, and agree that if I should become subject to the workers' compensation provisions of Section 37)0 of the Labor Code, l shall forthwith comply with those provisions. Date: / /lam Applicant: �� n WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000;. IN ADDITION TO THE COST OF COMPENSATION,, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND'ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT: Application is hereby made to the 3uilding Official for a permit subject to the conditions and restrictions set forth on this application. 1.Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application , the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the C-ty of La Quinta, its officers, agents, and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is . not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinEnces and state laws relating to building construction, and hereby authorize representati .,es of thiscity to enter up theabove. mentioned pr p/erty for inspection purposes. Date: r/ Signature (Applicant o FINANCIAL • • + DESCRIPTION'S 'f,{� j'.>QTY x` ANIOUNT� PAIb€ '" *PAID DATE. ACCOUNT BSAS SB1473 FEE 101-0000-20306 0 $1.00 $0.00 f ,+,METHODp E RECEIPT# ` CLTDBY` Lf r.> ,, .z` E=CHECK# Total Paid forBUILDING STANDARDS ADMINISTRATION BSA' $1.00. $0.00 °e DESCRIPTION ' ,. ° { 'ACCOUNT QTY AMOUNT MA � PAID a ` .,�g PAID. DATE PV SYSTEM - ARRAY, FIRST 20 101-0000-42403 0 $24.17 $0.00 *PAID BY ' 'fig , `METHOD " ` RECEIPT# y. =CHECK#CLlDBY E' * DESCRIPTION > ° QTY AMOUNT t PAD . PAI'iD.:'.. DXA" TE?:ACCOUNT - y _. x a PV SYSTEM — ARRAY, FIRST 20 PC 101-0000-42600 0 $24.17 $0.00 Y O'NPAIDBY ` METHOD r t $3x<3E RECEIP.-T # r CHECK #, 3 BY ; a '12 qCLTD .5 FrV'1 Total Paid for ELECTRICAL: $48.34 $0.00 e DESCRIPTION'' w ACCOUNT r " ,QTY`S AMOUNT PAID `PAID DATE,. y _ PERMIT ISSUANCE 101-0000-42404 0 $91.85 $0.00 E PAID'BY ' 'r ��". ' RECEIPT # 7 CHECK # CLTD BY N > AMETHOD , ... , r. c. Total Paid for PERMIT ISSUANCE: $91.85 $0.00 TOTALS:00 r Description: ALLISON/(16)ROOF MOUNTED PANELS (1)INVERTER - Type: SOLAR Subtype: Status: APPROVED Applied: 4/14/2015 SKH Approved: 4/16/2015 JFU Parcel No: 764550034 Site Address: 81820 RUSTIC CANYON DR LA QUINTA,CA 92253 Subdivision: TR 30023-7 - Block: Lot: 77 Issued: Lot Sq Ft: 0 Building Sq Ft: 0 Zoning: Finaled: Valuation: $9,193.00 Occupancy Type: Construction Type: Expired: No. Buildings: 0 No. Stories: 0 No. Unites: 0 Details: 4.16 kW SOLAR ARRAY -. (16) 255W KYOCERA KU2606XPA PANELS, W/ (1) ABB PVI-3.6-OUTD-S-US-Z-A INVERTER [256SF] 2013 CALIFORNIA ELECTRICAL CODE. j Applied to Approved ...i 1 i� ir, ..i��.. � d►DDITIONAL�SITCS „w FINANCIAL INFORMATION Printed: Thursday, April 16, 2015 11:18:28 AM 1 of 2 CRWIMEWS CHRONOLOGY CHRONOL06YTYPE = STAFF NAME ACTIONDATE ,', COMPLETION DATE NO ESQ - ' T _-x.. .� ....; ..y1' _ _.. - NOTIFIED MELANIE W/ SOLAR CITY THAT PLANS WERE E-MAIL JAKE FUSON 4/16/2015 4/16/2015 APPROVED AND PERMIT WAS READY TO ISSUE. ' CONDITIONS, -NAME TYPE , NAME '* a ADDRESS1- CITY -" STATE ZIPS PHONE _`FAX EMAIL APPLICANT SOLARCITY CORPORATION 3055 CLEARVIEW WAY SAN MATEO CA 94402 mplasse@solarcity.com CONTRACTOR SOLARCITY CORPORATION 3055 CLEARVIEW WAY SAN MATEO CA 94402 mplasse@solarcity.coM OWNER JULI CONWAY 844 CREEKSIDE DR SE SALEM OR 92253 „w FINANCIAL INFORMATION Printed: Thursday, April 16, 2015 11:18:28 AM 1 of 2 CRWIMEWS v 17q� '-F: . ............ ........ ................. . j'7 -7,4 ' 'r . ......... . .............. .......... ....... . .......... .......... DESCRIPTION I ",1'4ACC0 U AIVIUUNI 7- L) E RECEIPT # „CHECK # 4--A ,B BSAS SB1473 FEE 101-0000-20306 0 $1.00 $0.00 Total Paid for BUILDING STANDARDS ADMINISTRATION $1.00 $0.00 BSA: PV SYSTEM - ARRAY, 101-0000-42403 0 $24.17 $0.06 FIRST 20 PV SYSTEM - ARRAY, 101-0000-42600 0 $24.17 $0.00 FIRST 20 PC Total Paid for ELECTRICAL: $48.34 $0.00 --T-101-0000-42404 PERMIT ISSUANCE $91.85 $0.00� Total Paid for PERMIT ISSUANCE: $91.85 $0.00 TOTALS: $141.19 $0.00 PARENT PROJECTS Printed: Thursday, April 16, 2015 11:18:28 AM 2 of 2 cffW'1ySTcmS Bf° C[ty Of La Quinta Buitdillg 8r Safety Division P.O. Box 1504,'78-49S Calle Tampico La.Quints, CA 92253 -:(760) 777-7012 Building Permit Application and Tracking SF eet Pemlit # ProjectAddress: % Owner's Name:. DG( �fl A- P. Number. y� Address: g(si, o C. }" Legal Description: City, ST, zip: La Quinta, CA Contractor. Solar City Teleph > Address: 3055 Clearview Way. "Jed Description: � roof mounted solar panels . city, ST, zip: San Mateo, CA, 94402 1 inverter(s) Telephone: 650-638-1028 State Lia # : 888104 City Lia #; Arch, Eng<., Designer Address: City, ST, zip: Telephone: State Lia #: NameofContactPerson:Melanie Plasse Construction Type: Occupancy: Project type (circle one): New Add'n Alter Repair Demo Sq.Ft.: #Stories: #Univ: Telephone # of contact Person: 7.610-552-0663 Estimated Value of Project: q f c9"3 iV1. l � �W�O �GtVC(i-I 66 WPLICAN'C: DO NOT WRITE BELOW THIS LINE # Submittal Req'd Reed TRACKING PERMIT FEES Plan Sets Plan Check submitted Item Amount Structural Cake. Reviewed, ready for corrections �j Plan Check l)tposit. . Truss Cates. Called Contact Person y 6 Plan Check 8slanee _ Title 24 Cales. Plans picked up Construction Flood plain plan Pians resubmitted.. Mechanical Grading plan 2'fu ! Review, ready for correctiow �sue Electrical Snbeoutactor List Called Contact Person Plumbing Grant Deed Plana picked up S bLL ILO A. Approval Plans resubmitted Grading IIV HOUSE: -2" Review; ready for corrections/issuc Developer Impact Fee Planning Approval. Called Contact Person A.LP.P. Pub. VVlks. Appr Date of permit issue Scholl Fees Total PerknilFees Trilogy;at La Quinta '.,_ "� ,_ C\;4- , 60-750 Trilogy Pkwy K �j ps ® , il La Quetta, CA 92253 � - '1 . Ph 760=7776059',; +: (itler^qt La pmlto`�lasoaaacaAssaiiat�n. ;' +:. Fax: 760.-777-1620 Ap.ril..10,;;2015 , ';JAM Es -,ALLISON /MARGARET ALLISON 21903 E.HERITAGE Pkwy j a ' Aurora'CO80Dl6 ,I RE: Design Review Modification Conditionally Approved ' 81,820 Rustic Canyon Dr/ Customer ID #:. TRLA_Q.-0960=Q2 ' Dear. James:A11ison Margarel 70son ,. ;We arelpleased'to inform you that your -plans for -installation of�soiar panels; received 'on >~,pril 8, 2015, have a been. approved by the0esign Review. Corrimittee;.with ahe following conditions 19 and 23: Any, exterior piping}or conduit must be painted to`inatch adiacent surface (see attached copyk ,h Please note• Any damages causedby contractors°due-to constructi'on,must, be:repaired. . r �. This approval :does not constitute consent by.tfie Association for the applicant I to encroach=, trespass,, or build on. any property -other than that of the applicant Th"is approval isrelateto theitems reserved for approval, by the,CC&R:'sJnn accordance`with'.the Design Review Guidelines. The approval does not extend to the quality of s work done by your architect;, or contractor, or to any structural engineering, soils'enginee'ng, or site grading. +. ,'and drainage:design. Yo,u are urged to.obtain;the, services of a state licensed professional for consultation a`s, ,,needed, - The Designr.Rev'iew Committee is composed' of volunteers. "As,such; it does not review appications'to ensure. compliance with building codes, or other local or stateJaws. please be,advised that this,ap.proval does not relieve you from obtairnng any necessary building' perrhits from,the governmental agencies:fnvolv:d to. ens ure! , j compliance with these codes.: Any, violations of these -ordinances wlll'b:e your resgonsibllityao correct: Thank.you fOr your patience in til is matterand for co'replying'with the Association S pOlicies'and static=ardSs, .:Sincerely, �,. , : +'For the bes'ign:Review Committee; Ct`_-rw�1 .. ,. •�tvw,-r+•�.Y..W�+t+'.�--#•..'.w""Te!•`y.!'7.i„"'cw... ... _.«. .��i'rr.•.^.w w... , _ .-•w... a.� ... _.. `."'t:.",�4r»•...-.:.,..-.,-.r-n.....•� �.. Mirna. Hernandez ' -•,`, :Asst Manager On Site Property ` :Enclosures •cc _Board q: Directors Design Review Committee , Jr; • t th - ^i• _ f r f '' - r w ` f of , • _ _ #a ; .• - •• 1. . .- . � '• - r' /�J ...s Trilogy at La Quinta 60-750 Trilogy Pkwy La Quinta, CA 92253 Ph: 760-777-6059. Fax: 760-777-1620 April 9, 2015 ]AM ES ALLISON / MARGARET ALLISON 21903 E HERITAGE Pkwy Aurora CO 80016 RE: Design Review Modification Received 81820 Rustic Canyon Dr / Customer ID #: TRLAQ-0960-02 ear James Allison 7 Margaretison : Trilogy `.� Trdo&yat l.a Qaiatn Wisbplr,Qce Aeaotis"00 This shall confirm receipt of an Design Review submission, received on April 8, 2015, for the above referenced address for installation of solar panels. Please be advised that the application and plans have been forwarded.to the Design Review Committee for review. The governing documents for your Association allow forty five days for review; however, we hope to have a response to you within 3-4 weeks. The Design Review Committee is composed of volunteers. As such, it does not review applications to ensure compliance with building codes, or other local or state laws. You are encouraged to contact the governmental agencies involved to ensure your plans comply with these codes. Thank you for your patience in this matter and for complying with the Association's policies and standards. Sincerely, For the Design Review Committee; Mirna Hernandez Asst Manager On -Site Property cc: Board of Directors 1 ABBREVIATIONS ELECTRICAL NOTES JURISDICTION- NOTES A AMPERE . 1. THIS SYSTEM IS GRID—INTERTIED VIA A ALL CONSTRUCTION SHALL COMPLY `WITH THE 2013 ' AC ALTERNATING CURRENT UL—LISTED POWER—CONDITIONING INVERTER. CALIFORNIA BUILDING, RESIDENTIAL, MECHANICAL, BLDG BUILDING 2. THIS SYSTEM HAS NO BATTERIES, NO UPS. ELECTRICAL, PLUMBING, ENERGY, AND GREEN - CONC CONCRETE 3. A NATIONALLY—RECOGNIZED TESTING BUILDING CODES AND THE LA QUINTA MUNICIPAL DC DIRECT CURRENT LABORATORY SHALL LIST ALL EQUIPMENT IN CODE EGC EQUIPMENT GROUNDING CONDUCTOR COMPLIANCE WITH ART. 110.3. • 1 (E) EXISTING 4. WHERE ALL TERMINALS OF THE DISCONNECTING EMT ELECTRICAL METALLIC TUBING MEANS MAY BE ENERGIZED IN THE OPEN POSITION, FSB FIRE SET—BACK A SIGN WILL BE PROVIDED WARNING OF THE GALV GALVANIZED HAZARDS PER ART. 690.17. GEC GROUNDING ELECTRODE CONDUCTOR 5. EACH UNGROUNDED CONDUCTOR OF THEAA GND GROUND MULTIWIRE BRANCH CIRCUIT WILL BE IDENTIFIED BY - _ �- e :W000C HDG HOT DIPPEDL GALVANIZED 'PH ' ASE AND SYSTEM PER ART. 210.5. I CURRENT 6.CIRCUITS OVER 250V TO GROUND SHALL - Imp' CURRENT AT MAX POWER COMPLY WITH ART. 250.97, 250.92(B). s - Isc SHORT CIRCUIT CURRENT 7. . DC 'CONDUCTORS EITHER DO NOT ENTER -- kVA KILOVOLT AMPERE BUILDING • OR ARE RUN IN METALLIC RACEWAYS OR , kW KILOWATT , ENCLOSURES TO THE FIRST ACCESSIBLE DC "" ^� OF � /l QUINTA LBW LOAD BEARING WALL DISCONNECTING MEANS PER ART. 690.31(E). V I� L.�1 ��I �t1 - MIN MINIMUM 8., ALL WIRES SHALL BE PROVIDED WITH STRAIN _ %BUILDING & SAFETY DEP' ` (N) NEW - RELIEF AT ALL ENTRY INTO BOXES AS REQUIRED BY AmmarAPPROVED NEUT NEUTRAL _ UL LISTING. - _ _ NTS NOT TO SCALE 9. MODULE FRAMES SHALL BE GROUNDED AT THE FOR CONSTRUCTION OC ON CENTER UL—LISTED LOCATION PROVIDED BY THE PL PROPERTY LINE MANUFACTURER USING UL LISTED GROUNDING POI POINT OF INTERCONNECTION HARDWARE. PV PHOTOVOLTAIC 10. MODULE FRAMES, RAIL, AND POSTS SHALL BE , SCH SCHEDULE BONDED'WITH EQUIPMENT GROUND CONDUCTORS. S STAINLESS STEEL STC STANDARD TESTING CONDITIONS 'z TYP TYPICAL UPS UNINTERRUPTIBLE POWER SUPPLY V VOLT r Vmp VOLTAGE AT MAX POWER _ VICINITY MAP INDEX Voc VOLTAGE AT OPEN CIRCUIT W WATT - • 'i�E� 3R NEMA 3R, RAINTIGHT� �'� ' �` i' t ' , PV1 COVER SHEET . �3;.,; ` ' _ PV2 SITE PLAN • PV3 STRUCTURAL VIEWS PV4 UPLIFT CALCULATIONS PV5 THREE LINE DIAGRAM LICENSE GENERAL NOTES r�� y - r w -yq,; ' 3� . r0 6 ONE LINE DIAGRAM 1. ALL WORK TO BE DONE TO THE 2013 t ''� �'� P% ELECTRICAL CALCULATIONS CA # 888104. " ` �'t t !4: sheets Attached CALIFORNIA BUILDING, CODE AND_ THE 2013'; t y- "` r 8iS20 Rtt�t+_ Cnyrgnr+ * f r CALIFORNIA"RESIDENTIAL CODE.. WITH N , tt s. ,yo A :�-- I i • : • 2. 'ALL ELECTRICAL WORK SHALL COMPLY _ ., 1 fit.: ,1—c s • THE 2011 NATIONAL .ELECTRIC CODE.AS AMENDED BY S�GanYa _. THE 2013 CALIFORNIA ELECTRIC CODE.. MODULE GROUNDING METHOD: ZEP SOLAR.., c ' ffEV BY DATE COMMENTS AHJ: La Quints •- • - NAME DATE COMMENTS UTILITY:PIrrigation Im erial District - 77 PREMISE OWNER 6 DESCPoPTION: DESIGN CONFIDENTIAL'- THE INFORMATION HEREIN JOB NUMBER: JB -9223204 0 !� .. - Y CONTAINED SHALL NOT BE USED FOR THE ALLISON, DAVID 1 ALLISON RESIDENCE _ Wenlie C en. g*�. • BENET,T OF ANYONE EXCEPT, SOLARCITY, INC., MOUNTING SYSTEM:A �",* S .o. IarCity " NOR SHALL IT BE DISCLOSED IN WHOLE OR IN ZEP Mighty Hook 81820 RUSTIC CANYON DR' 4.16 KW PV ARRAY ►�� • . r ,..... PART TO OTHERS OUTSIDE THE RECIPIENTS MODUn LA QUINTA CA 92253 = _ 3os5 aearview Way SOLARCITY SALATION, EXCEPT IN CONNECTION WITH ( ) # APN: 764550034 _ THE SALE AND USE OF THE RESPECTIVE 16 KYOCERA KU2606XPA SOLARCITY EOUIPMENT, WITHOUT .THE WRITTEN PAGE NAME: SHEET. REV: DATE - San Mateo, CA 94402 PERMISSION OF SOLARCITY INC. I"'iQtTR' (76O 771-5703 P 4 2 2015 T:(650) 638-1028 F:(650) 638-1029 ABB PVI=3.6—OUTD—S—US—Z—A _ \ ) COVER SHEET ' / / (888) -SOL -CITY (765-2489) www.sdarcatycom 4 rt' r ' �`► GC_' SAFETY [)r FOR ��V� PITCH: 18 ARRAY PITCH: 18 MP1 AZIMUTH: 175 ARRAY AZIMUTH: 175 MATERIAL: Spanish Tile STORY: 1 S1 rKAJ:10\\\V/ X%0 � 3 ' ; 9� ,. �� LEGEND H014ToOUARM03 66401 U E '011 w® o o a (E) UTILITY METER & WARNING LABEL �`�""��"► h'Ing INVERTER W/ INTEGRATED DC DISCO / r ® o & WARNING LABELS �' Ia © DC DISCONNECT & WARNING LABELS / I A PV3 ml AC © AC DISCONNECT & WARNING LABELS LL MI I DC JUNCTION/COMBINER BOX & LABELS TRANSFORMER INFORMATION: _ I Q DISTRIBUTION PANEL & LABELS KVA PHASE 200A, 240V, SINGLE PHASE, QM �In��l Ac = J L _7F Lc LOAD CENTER &WARNING LABELS HIGH KV 2 WIRES, 22kAiC LOW 120/240V EXISTING BI DIRECTIONAL O DEDICATED PV SYSTEM METER METER#1B4SR-115101 —METER# 1 B4SR-115101 w s Front Of House (E)DRNEWAY Q STANDOFF LOCATIONS "PROPOSED 61—DIRECTIONAL CONDUIT RUN ON EXTERIOR METER#—_------�-' 81820 Rustic Canyon Dr CONDUIT RUN ON INTERIOR— CUTLER—HAMMER # DG221URB �, �, Q GATE/FENCE HEAT PRODUCING VENTS ARE RED — AC DISCONNECT: /' + _ INTERIOR EQUIPMENT IS DASHED 5 FT FROM MAIN PANEL N SITE PLAN — INVERTER: ABB # PVI-3.6—OUTD—S—US—Z—A Scale:1/16" = 1' yy E 01, 16' 32' ho row" S CONFIDENTIAL —THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE JOB NUMBER JB -922,3204 00 PREMISE D"NM- ALLISON, DAVID DESMPPON: ALLISON RESIDENCE DESIGN: wenjie Chen SolarCity. BENEFIT OF ANYONE EXCEPT SOLARCITY INC., NOR ALL IT BE DISCLOSED IN WHOLE OR IN 81820 RUSTIC CANYON DR 4.16 KW PV ARRAY wi ll MOUNTING SYSTEM: ZEP Mighty Hook y;. $ PART TO OTHERS OUTSIDE THE RECIPIENTS LA QUINTA, CA 92253 MODULES: ORGANIZATION, EXCEPT IN CONNECTION NTH THE SALE AND USE OF THE RESPECTIVE (1 6) KYOCERA KU2606XPA ( ) # PAGE NAME _ Son Mateo, CAw94402 SHEET: REV: DATE SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF SOLARCITY INC. INVERTER: ABB PVI-3.6-006-S—US—Z—A (760) 771-5703 SITE PLAN PV 2 4/2/2015 T:(650) 638-1028 F:(650) 638-1029 (868)—SOL—aTY (765-2489) www.solarcity.com INSTALLATION ORDER ZEP SPANNER BAR LOCATE RAFTER, MARK RAFTER (6) LOCATION, AND REMOVE TILE (1) PLACE STANDOFF BASE & DRILL S1 PILOT HOLES AT THE RAFTER �^ " DIA BOLT & NUT (1) (2) (Z) 3 O 2) CLEAN PAPER AROUND PILOT • HOLE. ZEP SPANNER BAR CLAMP 3) ADJUST STANDOFF TO BATTEN HEIGHT. '-3" —2" 5-9" STANDOFF SEAL PILOT HOLES' AND BOTTOM '` 1'- (E) LBW - (E) TILE ((4) OF STANDOFF WITH'POLYURETHAN ' (E) ROOF DECKING (5) (4) SEALANT. SIDE VIEW OF MP1 NTS 5/16 DIA STAINLESS ~ 5) LAG STANDOFF INTO RAFTER. STEEL LAG BOLT (2-1/2" EMBED, MIN) LOWEST MODULE SUBSEQUENT MODULES" 6) NOTCH TILE WEATHERING TO FIT (E) RAFTER STANDOFF AROUND STANDOFF. y Scale: 1 1/2 = 1' Z) REINSTALL TILE. MP1 X -SPACING X -CANTILEVER Y -SPACING Y -CANTILEVER I NOTES LANDSCAPE 48" 24" 52" 52" 24" 24" PORTRAIT 48" 20" TOP CHORD 2X4 @ 24" OC ROOF AZI 175 PITCH 18 STORIES: 1 INVERTER ABB PVI-3.6-OUTD—S—US—Z—A ARRAY AZI 175 PITCH 18 BOT CHORD 2X4 @24" OC S -Tile (Cement) - CONFIDENTIAL - THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT SOLARCITY INC., NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE THE RECIPIENTS ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE SOLARCITY EQUIPMENT,' WITHOUT THE WRITTEN PERMISSION OF SOLARCITY INC. JOB NUMBER: JB -9223204 00 PREMIA OWNER: DESCRIPTION: — -- ALLISON, DAVID ALLISON RESIDENCE 81820 RUSTIC CANYON DR ' ' ' 4.16 KW PV ARRAY LA QUINTA CA 92253 • , I PAGE NAME 76O 77.1-5703 � ) STRUCTURAL VIEWS(BBB)-Sol-arr DESIGN: Wenjle Chen �„�a, ';SolarCity MWNIING SYSTEM: ZEP Mighty Hook ; . N1Ar1vvi__� MODULES: (16) KYOCERA # KU2606XPA Way on M teo,CleaCA 44 San Mateo, F: 94402 )-SOL) tTY (7 5 F:9) w 636-1029 (�65-2489 �,..sola,dtYaon SHEET RE .. DATE PV 3 4/2/2015 - INVERTER ABB PVI-3.6-OUTD—S—US—Z—A CONFIDENTIAL - THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT SOLARCITY INC., NOR SHALL IT BE DISCLOSED IN "IDLE OR IN PART TO OTHERS OUTSIDE THE RECIPIENT'S ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE SOLARCITY EQUIPMENT, WITHOUT THE WRIIIEN PERMISSION OF SOLARCITY INC. JOB NUMBER: JB -9223204 00 MOUNTING SYSTEAk ZEP Mighty Hook MODULES: (16) KYOCERA # KU2606XPA INVERTER: ABB # PVI-3.6—OUTD—S—US—Z—A ALLISON, DAVID 81820 RUSTIC CANYON DR LA QUINTA, CA 92253 (760) 771-5703 UPLIFT CALCULATIONS 04.02.2015 "��f • PV System Structural Version *43.0 � ���,aSolarQt 's 1 Desi a n Software '' 1t rlttta(ti'c +A Table Of EofttelR�ts Risk Category: II PV System Type S61WOty SleekMou it'" Spanish Tile Roof Spanish Tile Roof ers of Comp Rooftn Roof Slope 180 Rafter Soadno 24" C3.C: PV System Module Orientation Landscape and Portrait PV Module Area. 2.83 sf PV Module Width 39" PV Nodule Length 65" Standoff Attachment Hardware Mlahty Hook HDG ST Reduced Ground/'Roof Live/snow Loads Ground Snow Load pg 0.0 psf ASCE Table 7-1 SurrOuxding Roof Snow 0.0 psf ASCE Eq: 7.4-1 Roof Snow Over PV Modules 0.0 ASCE Eq: 7.4-1 Wind Des€ ' CrRe a Wind Design Code ASCE 7-10 Mod Design, McOW Pardally%F* Enclosed Method Basic Wind Speed V 110 mph Fig. 26.5-1A Exposure Category C Section 26.7 Roof Style Gable Roof e9.30.4-2A/B/c-5N8 Mean Roof Height h 1519t Section 26.2 Effective Wind Area 1 Module A 17.7 sf IBC 1509.7.1 WtnN :Rr�swre Ca'ku1gt1bh Coeff"Mts Wind Pressure Exposure Kz 0.85 Table 30.3-1 Topographic Factor Kit iwoo Section 26.9 Wind Directionality Factor Kd 0.85 Section 26.6-1 Impottance Factor I NA Velocity Pressure qh qh = 0.00256 (Kz) (Kzt) (Kd) (V^2) Equation 30.3-1 22.4 psf Ext Pressure Coefficient (Up) GCp (Up) -0.88 rig. 30.4-2A/8/c-5N8 Ext Pressure CoAclent m 0:45 FQ. 30,4-ZANO"' Design Wind Pressure= h GC Equation 30.4-1 WW Pressure Up P40) -19.6 ;psf Wind Pressure Down down 16.0 psf Max Allowable Standoff Spacing Landscape 48" 52" Max AtloweElble Cantilever LondmVe 24" 24" Standoff Confiquration Landscape Not-Sta ered Max;Slan,4off Tributary Area ITrlb 17 sf PV Assembly Dead Load W -PV 3 psf Net l)p4ft et Standoff T -actual -174 lbs Uplift Capacity of Standoff T -allow 350 lbs 3tindo f. , ,:: DCR. 49.6% Max Allowable Standoff Spacing Portrait 48" 52" "Att a Cantilever Port 20" 247 Standoff Configuration Portrait Not Sta eyed Max 9tanOff Tributary Area To 17 sf PV Assembly Dead Load W -PV 3 psf Net wind uplift bt Spnaloff T-actow _ _ -174 U _ Uplift Capacity of Standoff T -allow 350 lbs Standoff Doman' [>DZ. _ _ _ 494%. ALLISON RESIDENCE 4.16 KW PV ARRAY PAGE NAME UPLIFT CALCULATIONS Wenlie Chen SHEET: REV. DATE- PV ATEPV 4 4/2/2015 =;;SolarCity. y�Q 3055 Cleorvlew Way San Mateo, CA 94402 T:(650) 638-1028 F:(650) 638-1029 (888) -SOL -CITY (765-2489) www.adardty.com GROUND SPECS MAIN PANEL SPECS GENERAL NOTES INVERTER SPECS MODULE SPECS LICENSE BOND (N) #8 EGC/GEC TO (E) LIFER AT Panel Number: MC2442B1200SEC Inv 1: DC Ungrounded INV 1 — (1) ABB # PVI-3.6—OUTD—S—US—Z—A LABEL: A — (16) KYOCERA # KU2606XPA CA # 888104 PANEL WITH IRREVERSIBLE CRIMP Meter Number: lB4SR-115101 FCI Inverter; Zigbee 360OW, 240V, 96% PV Module; 260W, 232.9W PTC, 40MM, Blk Frame, H4, ZEP, 1000V, w/Ba kbar C-10 INV 2 Underground Service Entrance Voc: 38.3 Vpmax: 31 INV 3 Isc AND Imp ARE SHOWN IN THE DC STRINGS IDENTIFIER �E� 200A MAIN SERVICE PANEL E20OA/2P MAIN CIRCUIT BREAKER ADJUST.MIN. ACTIVATION VOLTAGES! solarcity CUTLER—HAMMER Inverter 1 IND 4 A 1 200A/2P Disconnect 5 ABB oC, Vstart = 120V PVI-3.6—OUTD—S—US—Z—A I DC- MP 1: 1x8 (E)LOADS B L1 F --- GC ----------=—-------- -- —E -----------------3 L2 - DC+ - - 20A/2P GND--— ——— -———————— —— N DG I ——————— —————— — — — —— —— — EGC/ --- DC+ 3 2 DC+ Vstart = 12OV ---- A B I cEc � D Do GND EGC--- 0o MP 1: 1X8 EGC --- ---____-- —---—— —— — —-----�---- -- —--— —— —— ————- —— — ----j r . (I )Conduit Kit; 3/4' EMT N I EGCIGEC —� - Z Z C7 . --- GEC TO 120/240V I _ SINGLE PHASE UTILITY SERVICE I I CITY OF LA QUINTA BUILDING & SAFETY DEPT. �- APPROVED PHOTOVOLTAIC SYSTEM CONDUCTORS SHALL BE IDENTIFIED FOR CONSTRUCTION AND GROUPED. THE MEANS OF IDENTIFICATION SHALL BE PERMITTED BY SEPARATE COLOR CODING, MARKING TAPE, TAGGING, OR OTHER APPROVED MEANS. THE MEANS OF DATE BY • GROUPING SHALL BE WIRE TIES OR SIMILAR MEANS AT LEAST ONCE, AND THEN AT INTERVALS NOT TO EXCEED SIX (6) FEET. PHOTOVOLTAIC EQUIPMENT AND SYSTEMS AND ALL ASSOCIATED WIRING AND INTERCONNECTIONS SHALL BE ` Voc* = MAX VOC AT MIN TEMP INSTALLED ONLY BY QUALIFIED PERSONS ' Poj (1) SIEMENS ® 022D PV BACKFEED BREAKER Breaker, 20A 2P, 2 Spaces B (1) CUTLER—HAMMER ®DG221UR8 /fj Disconnect; 30A, 240Voc, Non—Fusible, NEMA 3R /-� A (1) SolarCityy 4 STRING JUNCTION BOX D 2x2 S1R�GS, UNFUSED, GROUNDED — (i)CUTLER—HAMMER M DG03ONB Ground eutral It; 30A, General Duty (DG) F r O (1)AWG 810, THWN-2, Black (1)AWG 810, THWN-2, Red (1)AWG 810, THWN-2, White NEUTRAL Vmp =240 VAC Imp=16 AAC 1)AWG /10, THWN-2, Black Voc* = 345.01 VDC (1)AWG ,10, THWN-2, Red Vmp = 248 VDC Ok _ _ .Green EGC "EGC" , , " " , • ..... . Isc = 9.09 ADC Imp= 8.39 ADC (2)AWG 810, PV WIRE, Black Voc* = 345.01 VDC Isc = 9.09 ADC O (1)AWG 810, Solid Bare Copper EGC Vmp = 248 VDC Imp= 8.39 ADC .... , ..-0 )AVYG 88,.'R "N-2,. Green .. EGC/GEC,—(1)Conduit. Kit;. 3/4".EMT .......... (1 AWG #10, THWN-2, Black Voc* =345.01 VDC (1) AWG 110, THWN-2, Red Vmp = 248 VDC .... ISc = 9.09 ADC Imp 8.39 ADC ......... (2)AWG 810, PV WIRE Black Voc* = 345.01 VDC Isc ='9.09 ADC O (1)AWG 810, Solid Bare Copper EGC Vmp 248 VDC Imp= 8.39 ADC it .......... (1)AWG /10, THWN-2,.Green.. EGC r -wi CONFIDENTIAL — THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT SOLARCITY INC., JOB NUMBER: J B-9223204 00 PREMISE OWNER: DESCRIPTION: ALLISON, DAVID ALLISON RESIDENCE 81820 RUSTIC CANYON DR DESIGN: Wen11e Chen ' S'OI���' 'iii y MOUNTING SYSTEM: NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE THE RECIPIENTS ZEP Mighty Hook 4.16 KW PV ARRAY LA QUINTA CA 92253 ORGANIZATION, EXCEPT IN CONNECTION MATH THE SALE AND USE OF THE RESPECTIVE MODULES. (16) KYOCERA # KU2606XPA � " • 3055 Clearview Way SHEET REV. DATE. PV 5 4/2/2015 SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF SOLARCITY INC. NAME (760) 771-5703 -. THREE LINE DIAGRAM T.-(650) T: (650) Son Mae F:(650�638-1029 (888)—SOL-CITY (765-2489) www.solarclty.c«a INVERTER: ABB # PVI-3.6-0UTD—S—US—Z—A • EXISTING UNDERGROUND ELECTRICAL SERVICE ENTRANCE 200A 122 WC 1240V 1 PHASE 13 WIRE ELECTRICAL ONE LINE DIAGRAM !ll8 ht ,. ll PHOTOVOLTAIC SYSTEM UTILITY DISCONNECT SWITCH CUTLER -HAMMER # DG221URB 30A, 240VAC u — (1)Conduit Kit; 3/4" EMT 5 (1) AWG #10, THWN-2 (1 ) AWG #10, THWN-2 (1) AWG #10, THWN-2, White (1) AWG #8, THWN-2, Green, EGC • Vmp = 240 VAC Imp = 16 AAC YAC DC 3600 WATT UTILITY INTERACTIVE IN RTE 120 TO 600 VDC TO 120 /240 V C 10 ABB PVI-3.6-OUTD-S-US-Z- (1)Conduit Kit; 3/4" EMT PHOTOVOLTAIC SYSTEM JUNCTION BOX SolcrCity # 4 STRING JUNCTION BOX 2x2 STRINGS, UNFUSED, GROUNDED 3 (1) AWG #10, THWN-2 (1) AWG #10, THWN-2 ( 1 ) AWG #10, THWN-2, Green EGC (l Al (1) AWG #10, THWN-2 (1) AWG #10, THWN-2 (1) AWG #10, THWN-2, Green EGC PV ARRAY #1 8 MODULES KYOCERA # KU2606XPA 2080 WATT (DC) PV ARRAY #2 8 MODULES KYOCERA # KU2606XPA 2080 WATT (DC) (2) AWG #10, PV WIRE, Black vL (1 ) AWG #10, Solid Bare Copper EGC (2) AWG #10, PV WIRE, Black vL ( 1 ) AWG #10, Solid Bare Copper EGC CONFIDENTIAL -THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE r.�OOA/2P 1 20A/2P =;;,So�a�City. BENEFIT OF ANYONE EXCEPT SOLARCITY INC., NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE THE RECIPIENTS 81820 RUSTIC CANYON DR 4.16 KW PV ARRAY LA QUINTA, CA 92253� "` ELECTRICAL ONE LINE DIAGRAM !ll8 ht ,. ll PHOTOVOLTAIC SYSTEM UTILITY DISCONNECT SWITCH CUTLER -HAMMER # DG221URB 30A, 240VAC u — (1)Conduit Kit; 3/4" EMT 5 (1) AWG #10, THWN-2 (1 ) AWG #10, THWN-2 (1) AWG #10, THWN-2, White (1) AWG #8, THWN-2, Green, EGC • Vmp = 240 VAC Imp = 16 AAC YAC DC 3600 WATT UTILITY INTERACTIVE IN RTE 120 TO 600 VDC TO 120 /240 V C 10 ABB PVI-3.6-OUTD-S-US-Z- (1)Conduit Kit; 3/4" EMT PHOTOVOLTAIC SYSTEM JUNCTION BOX SolcrCity # 4 STRING JUNCTION BOX 2x2 STRINGS, UNFUSED, GROUNDED 3 (1) AWG #10, THWN-2 (1) AWG #10, THWN-2 ( 1 ) AWG #10, THWN-2, Green EGC (l Al (1) AWG #10, THWN-2 (1) AWG #10, THWN-2 (1) AWG #10, THWN-2, Green EGC PV ARRAY #1 8 MODULES KYOCERA # KU2606XPA 2080 WATT (DC) PV ARRAY #2 8 MODULES KYOCERA # KU2606XPA 2080 WATT (DC) (2) AWG #10, PV WIRE, Black vL (1 ) AWG #10, Solid Bare Copper EGC (2) AWG #10, PV WIRE, Black vL ( 1 ) AWG #10, Solid Bare Copper EGC CONFIDENTIAL -THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE JOB NUMBER:��� JB -9223204 0 0 POSE 0 DESGf8P11DN: ALLISON, DAVID ALLISON RESIDENCE DESIGIk Wenjie Chen =;;,So�a�City. BENEFIT OF ANYONE EXCEPT SOLARCITY INC., NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE THE RECIPIENTS 81820 RUSTIC CANYON DR 4.16 KW PV ARRAY LA QUINTA, CA 92253� "` MOUNTING SY51EM: ZEP Mighty Hook MODu�s r - `'Way ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE (16) KYOCERA # KU2606XPA PAGE NAME cross t e, CA 440 Son Mateo, CA 94402 SHEET: REV' DAIS THE WRITTEN PERMISSION EOFISOLARCITYINC. 760 771-5703 ) ONE LINE DIAGRAM PV 6 4 2 2015 / / (888)(SOL)CI381028 :(650) 38-102OLARCITY y.can INVERTER ABB PVI-3.6—OUTD—S—US—Z—A ELECTRICAL CALCULATIONS T String and 2 Combined Strings Module Type: Module Count: (cont = (Amps): Kyocera 260 1000V 16 11.36 - Branch Circuit Individual MPPT Derated ampacity 1 strings per Branch A 1 strings per Branch B 36.4 8 modules per series string 8 modules per series string String Branch A Branch B Conductor: Conductor: Conductor: Icont * 1.25 = (Amps) Icont * 1.25 = (Amps) 14.2 14.2 14.2 30 deg C ampacity = 40 40 40 , PV Wire Size: AWG #10 AWG #10 AWG #10 (cont = (Amps) 11.36 11.36 11.36 35 Start ampacity 40 40 40 , Temperature derate (%=F) 0.41 0.41 0.41 Conduit fill derate (%_#) 1 0.8 0.8 Derated ampacity 16.4 13.12 13.12 �(cont * 1.25.= (Amps) 14.2 14.2 14.2 Ampacity ` -- 40 40 • Inverter Output y Inverter Type: Inverter Count'.' Total ABB PVI -3.6-S AFCI 1 i'' (cont = (Amps): 16 Icont * 1.25 = (Amps) 20 OCP Size = 20 Conductor 3: - AWG #10 THWN-2 .. . . (cont * 1.25 = (Amps) _ 20 - 30 deg C ampacity = 40 Icont = (Amps) 16 Start ampacity 40 Temperature derate (%=F) . 0.91 , Conduit fill derate (%=#) 1 Derated ampacity 36.4 Icont * 1.25 = (Amps) 20 Ampacity 35 , 74 9A cb100 R0:3, ) .. . . CONFIDENTIAL — THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE JOB NUMBER 'JB -9223204 O O- PREMISE OWNER: ALLISON, DAVID DESCRIPTION: ALLISON RESIDENCE DESI W. Wenpe Chen ��k ���,e, BENEFIT OF ANYONE EXCEPT SOLARCITY INC.; — NOR SHALL IT BE DISCLOSED IN WHOLE OR IN MOUNTING SYSTEM: ZEP Mighty Hook - 81820 RUSTIC CANYON DR"' 4.16 KW PV ARRAY 'i � olar �' ty PART TO OTHERS OUTSIDE THE RECIPIENT'S MODULES: LA QUINTA, CA 92253 3W-11 ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE- (16) KYOCERA # KU2606XPA PAGE NAME • ^ 3055 georvieM Way Son Mateo, CA 94402 SHEET REV DATE SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF SOLMCIIY INC. INVERTER-- ABB PVI-3.6-0UTD—S—US—Z—A 76O 771-5703 ELECTRICAL CALCULATIONS: PV 7 4 2 / /2015 )_SOL) 638-105 E89) w 638-1029' (BBB)-soL-aTY(765—z4Bs)a..csolordty.c°m Label Location: (C)(IC)(CB) Per Code: CRC R331.2 Label Location: (DC) (INV) Per Code: CEC 690.14.C.2 Label Location: (DC) (INV) Per Code: CEC 690.53 Label Location: (DC) (CB) Per Code: CEC 690.17 Label Location: (INV) Per Code: CEC 690.5(C) Label Location: (AC) (POI) Per Code: CEC 690.14.C.2 Label Location: (AC) (POI) Per Code: CEC 690.54 CONFIDENTIAL — THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT SOLARCITY INC., NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE THE RECIPIENT'S ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF SOLARCITY INC. Label Set Label Location: (AC) Label Location: (DC) Per Code: CEC 690.17 Label Location: (POI) Per Code: CEC 705.12.D.7 Label Location: (POI) Per Code: CEC 690.54; CEC 690.17 Label Location: (D) (POI) Per Code: CEC 690.64.B.4 Label Location: (POI) Per Code: CEC 705.12.D.7 Label Location: (DC)(INV)(CB) Per Code: CEC 690.35(F) TO BE USED WHEN INVERTER IS UNGROUNDED C TTY OF LA QUIN PA S gU1LDINGP AFEN®v E® ,AOf,CONSTRUC-TION <�f DATE_." (AC): AC Disconnect (C): Conduit (CB): Combiner Box (D): Distribution Panel (DC): DC Disconnect (IC): Interior Run Conduit (INV): Inverter With Integrated DC Disconnect (LC): Load Center (M): Utility Meter (POI): Point of Interconnection 3055 Clearview Way San Mateo, CA 94402 T:(650) 638-1028 F:(650) 638-1029 (888)SOL-CITY (765-2489) www.solarcity.com • SOIafClty I ZepSolar Next -Level PV Mounting Technology 1 QSolafCity, I ZepSolar • .. Next -Level PV Mounting Technology . i - Zep System r Components y for concrete the roofs lx 3x 4x Spanner Bar 1 � `• �• ' - '• _ ° • ' _ ... f Part hlnt, 850-1400 - 4x - 850-1399 - 3x 850-1398 - 1x , i - - _ y .:i� .-� •• Yom, � I I J 1• -'r •r: C r` ` � • ' - F `,s £ Splice Kit _ Spanner Clamp + " Part No. 850-1401 Listed to UL 2703 ' Part No. 850-1194 Listed,to UL 2703 `' .. ♦ � ,- W `OMPAP,e`er Description - f - • • .. ' :: - 1 - \ —r . h • W PV mounting solution for concrete tile roofs (Ill • s FA�t1MPPr0v ` Works with all Zep Compatible Modules- • Auto bonding UL -listed hardware creates structual and electrical bond Zep System has a UL 1703 Class "A" Fire Rating when installed using ` �I. LISTED modules from any manufacturer certified as "Type 1" or "Type 2" ` , y Y * ' ' Adjustable Mighty Hook Interlock w Cam Foot i • r , Part No. 850-1396 Part No. 850-1388 Part No. 850-1413 • • Listed to UL 2582 ,Listed to UL 2703 'Listed to UL 2703 ,-y ` r Specifications. +� - �� Designed for pitched roofs ' •, _ -t - • ' ✓ _ r'r �; +#�' wv w f ? t F x "Installs in portrait and landscape orientations "�• - ,. ,, "''_ ••. � t Zep System supports module wind uplift and snow load pressures to 50 psf per UL 1703, ' _ Wind tunnel report to ASCE 7-05 and 7-10 standards a Zep System grounding products are UL listed to UL 2703 and ETL listed to UL 467 " Zep System bonding products are UL listed to UL 2703 • ' • r �; , M - Engineered for spans up to 72" and cantilevers up to 24" + - Zep wire management products listed to UL 1565 for wire positioning devices ,.tr_ - 'i - k Ground Zep Array Skirt, Grip, End Caps DC Wire Clip - '� J Attachment method UL listed to UL 2582 for Wind Driven Rain K .. Part No. 850-1172 : Part Nos. 500-0113, Part No. 850-1448 F ` • •Listed to UL 2703 and 860-1421, 850-1460, ' Listed UL 1565 ETL listed to UL 467 850-1467 iepsolaccom �. + r 4 P _ Listed to UL 2703. - ze solaccom ' This document does not create any express warranty by Zep Solar or about its products or services. Zep Solar's sole warranty is contained in the written product warranty for This document does not create any express warranty by Zep Solar or about its products or services. Zep Solar's sole warranty is contained in the written product warranty for ;. • each product. The end-user documentation shipped with Zep Solars products constitutes the sole specifications referred to in the product warranty. The customer is solely {. beach product. The end-user documentation shipped with Zep Solar's products constitutes the sole specifications referred to in the product warranty. The customer is solely • . �q.' • s - responsible for verifying the suitability of Zap Solar's products for each use. Specifications are subject to change without notice. Patents and Apps: zspats.wm. .� '9 ; + responsible for verifying the suitability of Zep Solar's products for each use. Specifications are subject to change without notice. Patents and Apps: zspats.com. - - - 01 13 15 ZS for Concrete Tile Roofs Cutsheet Rev 02.pdf .. Page: 1 of 2 . - - . , 01 13 15 ZS for Concrete Tile Roofs Cutsheet Rev 02.pdf • _ _ Page: 2 of 2 + "` a' lx 3x 4x Spanner Bar 1 � `• �• ' - '• _ ° • ' _ ... f Part hlnt, 850-1400 - 4x - 850-1399 - 3x 850-1398 - 1x , i - - _ y .:i� .-� •• Yom, � I I J 1• -'r •r: C r` ` � • ' - F `,s £ Splice Kit _ Spanner Clamp + " Part No. 850-1401 Listed to UL 2703 ' Part No. 850-1194 Listed,to UL 2703 `' .. ♦ � ,- W `OMPAP,e`er Description - f - • • .. ' :: - 1 - \ —r . h • W PV mounting solution for concrete tile roofs (Ill • s FA�t1MPPr0v ` Works with all Zep Compatible Modules- • Auto bonding UL -listed hardware creates structual and electrical bond Zep System has a UL 1703 Class "A" Fire Rating when installed using ` �I. LISTED modules from any manufacturer certified as "Type 1" or "Type 2" ` , y Y * ' ' Adjustable Mighty Hook Interlock w Cam Foot i • r , Part No. 850-1396 Part No. 850-1388 Part No. 850-1413 • • Listed to UL 2582 ,Listed to UL 2703 'Listed to UL 2703 ,-y ` r Specifications. +� - �� Designed for pitched roofs ' •, _ -t - • ' ✓ _ r'r �; +#�' wv w f ? t F x "Installs in portrait and landscape orientations "�• - ,. ,, "''_ ••. � t Zep System supports module wind uplift and snow load pressures to 50 psf per UL 1703, ' _ Wind tunnel report to ASCE 7-05 and 7-10 standards a Zep System grounding products are UL listed to UL 2703 and ETL listed to UL 467 " Zep System bonding products are UL listed to UL 2703 • ' • r �; , M - Engineered for spans up to 72" and cantilevers up to 24" + - Zep wire management products listed to UL 1565 for wire positioning devices ,.tr_ - 'i - k Ground Zep Array Skirt, Grip, End Caps DC Wire Clip - '� J Attachment method UL listed to UL 2582 for Wind Driven Rain K .. Part No. 850-1172 : Part Nos. 500-0113, Part No. 850-1448 F ` • •Listed to UL 2703 and 860-1421, 850-1460, ' Listed UL 1565 ETL listed to UL 467 850-1467 iepsolaccom �. + r 4 P _ Listed to UL 2703. - ze solaccom ' This document does not create any express warranty by Zep Solar or about its products or services. Zep Solar's sole warranty is contained in the written product warranty for This document does not create any express warranty by Zep Solar or about its products or services. Zep Solar's sole warranty is contained in the written product warranty for ;. • each product. The end-user documentation shipped with Zep Solars products constitutes the sole specifications referred to in the product warranty. The customer is solely {. beach product. The end-user documentation shipped with Zep Solar's products constitutes the sole specifications referred to in the product warranty. The customer is solely • . �q.' • s - responsible for verifying the suitability of Zap Solar's products for each use. Specifications are subject to change without notice. Patents and Apps: zspats.wm. .� '9 ; + responsible for verifying the suitability of Zep Solar's products for each use. Specifications are subject to change without notice. Patents and Apps: zspats.com. - - - 01 13 15 ZS for Concrete Tile Roofs Cutsheet Rev 02.pdf .. Page: 1 of 2 . - - . , 01 13 15 ZS for Concrete Tile Roofs Cutsheet Rev 02.pdf • _ _ Page: 2 of 2 + "` This family of single-phase string inverters complements the typical number of rooftop solar panels enabling home -owners to get the most efficient energy harvesting for the size of the property. This inverter offers a dual input section that processes two strings with independent Multiple Power Point Tracking (MPPT). This is especially useful for rooftop installations with two different orientations from two sub -arrays oriented in different directions. (For example: East and West) The dual input sections with independent MPPT enable a more optimal energy harvesting condition. The high-speed MPPT offers real- time power tracking and improved energy harvesting. The flat efficiency curve ensures high efficiency at all output levels allowing a consistent and stable performance across the entire" input voltage and output power range. The transformerless operation gives the highest efficiency of up to 97.0%. The wide input voltage range makes the inverter suitable to low power installations with reduced string size. This rugged outdoor inverter has been designed to be a completely sealed unit able to withstand the harshest environmental conditions. Highlights: - Single phase and split phase output grid connection. - Wide input range for increased stringing flexibility. - The high speed and precise MPPT algorithm offers real time power tracking and improved energy harvesting. - Outdoor NEMA 4X rated enclosure for unrestricted use under any environmental conditions. - Integrated DC disconnect switch in compliance with international Standards (-S Version). Power and productivity „ 10 ,N for a better world" P PIP Additional highlights: - RS -485 communication interface (for connection to laptop or data logger). - Integrated Arc Fault Detection and Interruption (-A Version). Technical data and types 2 ABB Solar Inverters I Product Byer for PVI-3.0/3.6/3.8/4.2-Tl-OUTO .') , C KU260-6XPA , '` 1 • w `rPm,"` {VmP 30.8 31.0 V ImP 8.28 8.39 A` V. .. FFF 38.0 38.3 V, CUTTING EDGE TECHNOLOGY As'a pioneer with four decades of experience in the ' development of photovoltaic systems, Kyocera drives the' market as a leading provider of PV products. We ' demonstrate our Kaizen ,phi.l,osophy,.mor.commitment,to.. continuous improvement, by setting the industry standard 'in the innovation of best -in -class solar energy equipment QUALITY BUILT IN • UV -stabilized, anodized aluminum frame in black. Supported by major mounting structure manufacturers Easily accessible grounding points on all four corners , for fast installation - • Proven junction box technology With 12 AWG PV wire works with transformerless inverters •Amphenol H4-UTX locking plug-in connectors' , provide safe, quick connections PROVEN RELIABILITY Kyocera modules confirmed by the Desert Knowledge Australia Solar Centre to have the highest average 'output of any crystalline module • First module manufacturer in the world to pass long- term sequential testing performed by TUV Rheinland • Only module manufacturer to achieve the rank of, "Performance Leader" in all six categories of.GTM. 'Research's 2014 PV Module Reliability Scorecard s CERTIFICATIONS' UL1703 Certified and Registered, UL Module Fire Performance: Type 2, CEC - j • NEC 2008 Compliant, IEC 6121561730, and ISO 14001 F may• - - bsL - µ s.. `. o, ,. .'. a . - • r �W c�Lus ' KU -60 1000V Series f ELECTRICAL SPECIFICATIONS MODULE CHARACTERISTICS ; gtt KU260-6XPA , 255 260 w `rPm,"` {VmP 30.8 31.0 V ImP 8.28 8.39 A` V. .. FFF 38.0 38.3 V, Iss 8.83 9.09 .A we-ce - t 211 :., TnOCT .. ' 45 - - ' 45 - 0C tP� ffVmP 183 .187' W 27.7 27.9 V Im' 6.61 6.71 L A V� 34.8 35.1 V 7.15 , 7.36 A PTC 228.3 232.9 W �Pm -0.45 -0.45 %J°C I IV, -0.48. --0.48 %/°C.� , 0.02 0.02 %/°C tImP (� -0.36 -0,36 %'0C it IE 0.06 "0.06 %�°C Operating Temp -40 to +90 -40 to +90 Series Fu!Rating = 15A, Maximum DC System Voltage (UL) 1000V Hailstone Impact in (25mm) @ 51 mp (23m Js) ' Cells per module: 60 (6 x 10) v # r L Dimensions: 65.43ini38.98ini 1.57in length/Width/height (1662mmi990mmi40mm) Weight 47.4lbs (21.5kg) PACKAGING SPECIFICATIONS' Modules per pallet 20 ` Pallets per 53' container. 36 Pallet box dimensions: 66ini40ini43in length/Width/height (1675mr3i1005mm/1055mr J 'Pallet box weight 1060lbs (480kg) 14mW - - 4.73- . _'�'_.. tum•• - , - e� POTTED JUNCTION BO%0P65) t $ CABLE W/ - - CONNECTOR (I (+� ❑ f _ LABEL , STABILIZER BAR - - r STABILIZER BAR 1. 10" (28.) - •38.98-(990.0 i. �, - • Grounding Role,: Slotted 9 -ting Hole - j r - 0.16" (4m4 - 0.35",0.47- (G -1Z). .• .. ! . FRAME CROSS SECTION DIAGRAM 'Subject to simulator measurement uncertainty of +l- 3%. KYOCERA reserves the right to modify these specifications without notice. LONG/SNORT SIDE - STABILIZER BAR ' 4 NEC 2008 COMPLIANT' NG Read tM inslrucli°n t • UL 1703 USTED 4 QWARN L manual in i s entirety prior to r. ' _ 062614 - -. handling, installing8operat- - ing Kyocera Solar modules. - t OUR VALUED PARTNER ) __ - , Y rte, 1 4 I 3 �? 2 I 1 .I V-1 h u B m m .281 [5.51 DIA, KNOCKOUT QUANTITY 1 ID CENTRIC KNOCKOUTS FOR TANGENTIAL KNOCKOUTS FOR 3/4 CONDUIT 1/2, 3/4 CONDUIT cl- OTY 2 QUANTITY 4 0 3 M UNTING HOLES N B NGENTIAL KNOCKOUTS FOR N IANTITY 1 NOTE: 1. METRIC DIMENSIONS (IN MILLIMETERS) O 2. WIRE RANGE OF LUGS IS AS FOLLOWS u B m m .281 [5.51 DIA, KNOCKOUT QUANTITY 1 ID CENTRIC KNOCKOUTS FOR TANGENTIAL KNOCKOUTS FOR 3/4 CONDUIT 1/2, 3/4 CONDUIT cl- OTY 2 QUANTITY 4 276.81 DIA. 3 M UNTING HOLES m m B NGENTIAL KNOCKOUTS FOR '2, 3/4, 1 CONDUIT IANTITY 1 NOTE: 1. METRIC DIMENSIONS (IN MILLIMETERS) ARE SHOWN IN BRACKETS. 2. WIRE RANGE OF LUGS IS AS FOLLOWS LINE AND LOAD LUGS #6-#14 COPPER OR ALUMINUM NEUTRAL #4-#14 COPPER OR ALUMINUM A ra wnnunlcx ax r� aurins is VE wax QFEAmrmlreaw�nox WARREN SPE 8/19/98 CUTLER -HAMMER E'T• s H� PRTSBURGH PA a osa® Es¢xr Fox ra nw- R. PROHASKA 8/119/98 ^� DIMENSION SHEET Bose Fax rwex rt s Faaea�m. as 30 AMP TYPE 3R GENERAL DUTY 95-1445MING n wrem oacc (nmim xal !WL SS74DGCI 1-2 °°"°°°E a c --95-1 445 i ov 1 2 1 I Switching Devices - Safety Switches 1 « - OG321NR8 120/240 Vac General -Duty, Fusible, Single -Throw, continued' - s - t •���� t 4� 4 �"' y` 1,• .i `3 Fi .. Maximum Horsepower RetingsO , ®.''.E 1- ,-,.: *y w. a • Sli } �._FI cT a +,t . - NEMA1-NEMA3R - +�'•' PowenngBUSinessWo/Idw/d¢=' 'Single -Phase AC : Three -Phase AC DC + ? Ampere Fuse Type g - Enclosure Indoor Enclosure Rainproof - r _ e� System - flaring Provision 12W 240V 240V ZSOV • Catalog Number Catalog Number - . -, - Cartridge Type —Three -Pole, Three -Wire (Three Blades, Three Fuses) -240 Vac�'+ 30 60 r — _ — — — O O wy. E .10�, .• r a •.! '� ;' B + 100 -fx' 0221M..�-' t' - 0 o i�i r ^ ,1 •200 y 1 y, f T . . orb .. General u y ty V1, 400 . .• 400 FI — — 50-125 - DG325FGKOO - DG325FRKOO . `t. .. ��IIt d t , _ - r 600 H - - — 15-200 T. — - DC326FGKO0 DG326FRKOO '> - erre toC., a Se Urldad':S@rVIc10�II er0 .::: ,..,, , ;,, �1 • - Cartridge Type—Four-Wire (Three Blades, Three Fuses, S/N)-120/240 Vac - - - s•' -• g"`-' , r r - 2 Pd,1 e_ Non Pus i b 1 e- x series: aty ' 30 H — 1-1/2-3 3-7-1/2. OG32INGB OG32INRB - •`• - = • b b b r golds sin fusibl®s '-r� series 'B cant 60 - H - — 3-10 7-1/2-15 — OG32ZNGB DG322NR8 .t v •� _ `-s*.?cr j .MADE INU.9.A. J :'-•�� ,• X X X 100 H —+ 1-1R-15 15-30- — DC323NGB OG323NR8�:�. �- Te 3R Rain -roof �1 •-,t�..js '' '-NECNOENEU_A:4 SI1W2012 7 (7 i� 0 • - a 859149q' ' 200 H — 15 250 — DG324NGK DG324NRK _ - ,. `.,_.:, : ;,.�::.f;.,-- i '1 _ pp (q MA) Tipd .3R a. prueba;de LI i+ r ^ - - 400 H — — 50-125 — DG325NGK OG325NRK a - - + - - j' - t • . ; ` • 600 , H — 75-200 - DG326NGK OG326NRK by t '` - e + ` - r :�� ; ��^ + _ _. ., •r. rte-. '� � ! ��• z, ' - DG32ZUR8 120/240 Vac General -Duty, Non -Fusible, Single -Throw • ,_ , r •r • t, r' , . ' -•82113 1"2023. s Maximum Horsepower Ratings - _ , ...r .,p+ _ NEMA1 NEMA 3R .._a.;,:� -- - „r.,c..•:� .Y ./,_ _ - . _ Ampere Single -Phase AC Three -Phase AC DC Enclosure Indoor Enclosure Rainproof - ''• - � � IK�l System .Rating 120V 240V- 240V 250V Catalog Number Catalog Number - - - Two -Pole, Two -Wire (Two Blades) -240 Vac - " - * • . I I 30 2 3 — — DG221UGO 0 _ DG221URB (D- _ 60 3 10 — _ - — DG222UGBr•r-OG222URB r•� r - + + ` , .. _ • s 1 ' p 4 100 — 15 _ — - — DG223UGB0' DG223URB0 200 — — — _ — 00 s. • - r _ �. • . F. - - • - Three -Pole, Three -Wire (Three Blades) -240 Vee , + b b b 30 2 _ 3 7-1/2 — DG321UGB0 DG321URB0 _ 60 3 10 15 _ DG322UGB0 DG322URB0 - 1g0- — 15'• 30 — DG323UG6O DG323URB0 _ Y • _ + ` 200 � — 15 60. — DG324UGK0 DG324URK0 400 — — 125 — DG325UGK0 OG325URKO • i + t- + r _ 600 — — - 200 — DG326UGKOO OG326URKOO - i - • _ :i t• •� . .. Y Notes • • - a i a. + 4 - , - - - 0 Maximum he ratings apply only when dual element time delay fuses are used .. 0 Use four -wire catalog numbers below. J - • •• _ _ _ + - e+� • n i - ^ - - Solid neutral bars are not included. Order separately from table on Page 15. - _ - _ _ .! ..,-: - x _y ^,xt ` - +..: - i' '�' 1 s _, �; s k • • ,. - at • s s,' . t�, WARNINGI Switch is not approved for service entrance unless a neutral kit is installed. - • _ - �- , ;a. ' - -^ is,, ; '-' • - - ,�:.+� �+ ,, •• ' -'"' ;1 + - _ - ' , r - y+�' 'x;Y Or Use three -wire catalog numbers below. e - .. - 1 + L • _ _ -•' •r^` - _ 0 Drilled to accept field installed neutral kits. - ' a �'All general -duty safety switches are individually packaged. ' - Accessories are limited in scope on general -duty safety switches. See Page 15 for availability. In addition, clear line shields are available as an accessory- _, on 200-iWAgeneral-duty switches. Catalog Numbers: 200A=7Q7/59-II.40M=70.8063-8.600A=7(-8064-8. . + • - rr_ - it Iry 40 Volume 2—Commercial Distribution CA08100003E—February2011 wwweatoncom 27 - .•---.r+ - - :)I O b 1/2, 3/4 CONDUIT 1/2, 3/4 CONDUIT N a' O ouANnrY 2 QUANTITY 4 n Nn ri 0 27 6.8 DIA. N a 2.46 [62] 3 MOUNTING HOLES N N O .88 [22] c u 4.75 [121] m a n u B m A e z o ffi oe �. aimne 4 D 7 ID CONCENTRIC KNOCKOUTS FOR TANGENTIAL KNOCKOUTS FOR 1/2, 3/4 CONDUIT 1/2, 3/4 CONDUIT a' O ouANnrY 2 QUANTITY 4 n Nn ri 0 27 6.8 DIA. a 2.46 [62] 3 MOUNTING HOLES N N .88 [22] c u 4.75 [121] m a n 6 1.01 [26] TANGENTIAL KNOCKOUTS FOR 1/2, 3/4, 1 CONDUIT QUANTITY 1 nQ NOTE: 1. METRIC DIMENSIONS (IN MILLIMETERS) ARE SHOWN IN BRACKETS. .281 [5.5] DIA. 2. WIRE RANGE OF LUGS IS AS FOLLOWS COPPER R ALUMINUM TI NEUTRAL AOR QUANTITY .82 [46 .82 [46 N #4D#14000PPER ALUMINUM 6.10 [155] m l A tx[ wmwmx ox ms oxxnum rs d[rtmrtxrc or umx mxrm mx WARREN SPE 8/19/98 CUTLER—HAMMER IFX- rt e: o¢aosm w mraoertc i+a na PITTSBURGH PA. a NOf 10 BC RDMUGICA USm9 , an usaasm oittrr rm ra r1w- R. PROHASKA 8/19/98 ^^e DIMENSION SHEET rose rox rt s ntmraxm. oa 30 AMP TYPE 3R GENERAL DUTY 95-1 5-7445.DWC 5574DGMCICI I-2 A— s c [5---95-1445 i DF t 3 2 11 I ff ZepSol'ar Datasheet; ZS Tile Components Interlock Datasheet: ZS Tile f } 01 - The Interlock provides north -south and east -west structural and ground bond connections creating a structurally - contiguous hyper -bonded array. Interlock UL listed to UL 2703 and ETL listed to UL 1703. ZS Tile-' Leveling Foot a=t --I 131.25in - 1:21imj ^ -i "I 139AmmJ � I y 2 tnl I.SSin ...� 2.251n' laL2mm2.2 , .20in I 1 101.6mm] I•, �— d.00in fortile roofs 3 R f - The Leveling Foot provides a means of attachment between the PV array and the mounting surface or flashed attachment • ' - apparatus and allows for easy array height adjustment (1.25' Throw). t Array Skirt ZS Tile`" offers the fastest and least expensive way to install PV Zep Compatible' arrays on tile roofs. It's designed to interoperate with a growing list of Zep Compatible PV modules that incorporate the patented Zep Groove ZS Tile mounting hardware is designed for USB with Zep - frame specification. Utilizing quarter turn, rock in, and drop-in con The Array skirt facilitates easy front -row installation while providing a clean look at the front of the PV array. Compatible'" modules from nections, ZS tile eliminates the need for rails and separate grounding leading PV module Manufacturers. Ground Zep hardware while offering a superior aesthetic approach. - I Visit zepso[ar.com for a current list of Zep Compatible'" PV modules. The Ground Zep provides a point of connection between the PV array and the equipment grounding conductor. One Ground Zep is required for every 72 PV modules. UL and ETL listed to UL 467. UL listed to UL 2703. ^ Key System Benefits Key Technical Features Our Other Product Families Universal Box Bracket AC/DC Cable Clip Replacement Tile Dramatically reduces installation Low system weight ZS Aero _ time for low -slope & flat roofs Easily enables additional support ZS Comp" , Eliminated mounting rails and clip at array edges for high wind for composition shingle roofs hardware applications ' . ZS Seam' Eliminates separate grounding for standing seam metal roofs Interlock ETL listed to UL 1703 as The Universal Box Bracket allows rapid attachment of Clips into Zep Groove for ultra -fast and easy The Replacement Tile provides a means of flashed hardware ground bond means . ZS Span electrical boxes to the moduteframe. management of PV wiring and micro -Inverter cables. z attachment for ZS Tile installations. for rail -based applications - Rapid, top -accessible precision ' Array Skirt Cap Set Tools array leveling Ground Zep UL and ETL listed to UL ® ZS Trap' 467 as grounding and bonding device for trapezoidal metal roofs . Ultra reliable hyper bonded ZS Wave - grounding matrix Interlock, Leveling Foot, and Ground for corrugated roofs Zep listed to UL 2703 as PV bonding Ultra-low parts count device' The Array Skirt Cap Set provides an aesthetic cover for Zep TooL4 functions, I toot; Flat Tool: For inter -module Enhanced aesthetics the exposed end or the Array Skirt. Made of anodized removal. aluminum, each set comes with two Skirt Caps. ,c 4O"egrre (� r This document darn act ante ally cutest nimpty by hp Sob, sa or about its products or YlaL ZepSnfars sole nudirly is contained In theaniten product rodusuty for tab VIsitreksoter.com for more Information about out products and company. w �L LISTED produm.The eaduserdoumentation shipped with Zen Solar 'sproducts roostitmesThe solespecifications refuted to in the product uniandty.The a9mer ois sluff respandlih In • - - pe0"pPTev O verifying thtwiubifilyof InSular's pmdims lot each use Specifications are subject mchange adthaut notice Coppighl 2010-2011 Zep sour, Inc US Patent 97592.537. U.S. .� Page 1. Of 2 ` Patent&109.a&1Ltahtneaants Pending. Lao updatcfebman 212003:11 PM - Page 20/2 l . , SolarCity Standard Box 4J The SolarCity Standard Box 4J is a 4 -String unfused Junction Box. The box is highly configurable and adaptable using the (4) jumper blocks included in each box. A factory installed cordgrip enhances installer productivity. R SolarCity. m October 2013 • Manufactured to meet UL 1741 Standards. • Non -Metallic, Corrosion Resistant NEMA 4X Enclosure. • Factory -Installed Cordgrip Enhances Installation Speed. • Break-Thru Skinned -Over Glands on Cordgrip Provide Weathertight Seal for All Configurations. • Easily Configurable Terminal Blocks Permit Adaptation to Site -Specific Stringing Needs. Technical Data / Specifications OA Voltage Rating [VDC] :600V Maximum DC Current [A]: 57A © Maximum Continuous Current [A]: 42A OD Maximum Voltage [VDC]: 600V Wire Size Range [AWG): #6 to #14 OF Enclosure Rating: NEMA 4X ©G Operating Temperature Range [°C]: -40 to 50 OH Typical Overall Dimensions [in]: 8"x6"x4"