Loading...
07-2071 (SFD)P.O. BOX 1504 787495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 Application Number: 07-00002071 - Property Address: 81928 RUSTIC CANYON DR APN: 764-280-999-69' -300237- Application description: DWELLING - SINGLE FAMILY Property Zoninq: MEDIUM HIGH DENSITY_ RES Application valuation: 157369 BUILDING& SAFETY DEPARTMENT BUILDING PERMIT DETACHED' Applicant: Jrch;,te;ct or Engineer: K LICENSED CONTRACTOR'S DECLARATION I her y affirm rider penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Sect i 7000) f Division 3 of the Businesand Profes ionals Code, and my License is in full force and effect. - Lic ss: Liensu, _ e No.: 672285 ' ate: ntractor: OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the following reason (Sec. 7031 .5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the . permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law .(Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: (_ 1 I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractors' State License Law does, not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the. improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the,purpose of sale.). (_ I I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). ( 1 I am exempt under Sec. , B.&P.C. for this reason Date: Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ: C.). Lender's Name: Lender's Address: - LQPERMIT VOICE (760) 777-7012 FAX (760) 777-7011 INSPECTIONS (760) 777-7153 Date: 7/17/07 Owner:_ SHEA LA QUINTA C/O JEFF MCQUEEN 8800 N GAINE SFR t 0 Sf'.nTTSDA.T.R, 0 R9?SR• A Contractor: JUL 2 7 2007 SHEA HOMES., IN 1 60800 TRILO Y LA QUINTA, A 92 OF LA QUINTA (760)777-600 NANCE DEPT. LiC. No.: 672285 WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: I.have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. ' KI have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My on compensation insurance carrier and policy number are: Carrier 'AMERICAN HOME Policy Number "1247619 I certify that, in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject tot workers' compensation laws of California, Land agree that, if Id becA�ine subject to the ers' compensation provisions of Section µj00 of the p�'od I sha%forth4J-1hlco hose provisions. . WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the conditions and restrictions set forth on this application. 1. Each person.upon whose behalf this application is made, each person at whose request and for .. whose benefit work is performed under or pursuant to any permit issued *as a result of this application, the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. th t I have re d this application aestate the b e information is correct. I agree to comply with all ci�c(ordin ces an state lawsildi g structio and hereby authorize representatives, o is ou ty en above-mero 'trt r pection rposeDate: ignature Applicant: Application Number . . . . 07-00002071 Permit . . . BUILDING.PERMIT Additional desc . Permit Fee 842.50 Plan Check Fee 547.63 Issue Date Valuation . . . 157369 Expiration Date 1/13/08 Qty Unit Charge Per Extension BASE FEE 639.50 - 5R.0� 'i , r)nn 1 ---------------------------------------------------------------------------- T TnTT RTTIr i_nn nn1,-5nn nn0 203:00 Permit . . . MECHANICAL Additional desc . Permit Fee . . . . 73.00 Plan Check Fee 18.25' ` Issue Date Valuation . . . . 0 Expiration Date 1/13%08 Qty Unit Charge Per Extension BASE FEE 15.00 1.00 9.0000 EA MECH FURNACE <=100K 9.00 1.00 16.5000 EA MECH B/C >3-15HP/>100K-500KBTU 16.50 - 4.00 6.5000 EA MECH VENT FAN 26.00 1.00 6.5000 EA MECH EXHAUST .HOOD - 6.50 Permit . . . ELEC-NEW RESIDENTIAL Additional desc . Permit Fee 87.78 Plan Check Fee 21.95 Issue Date Valuation 0 Expiration Date 1/13/08 Qty. Unit"Charge Per Extension BASE FEE 15.00 1773.00. .0350 ELEC•NEW RES - 1 OR 2 FAMILY 62.06 536.00 .0200 ---------------------------------------------------------------------------- ELEC GARAGE OR NON-RESIDENTIAL 10..72 Permit . . .. PLUMBING . Additional desc . Permit Fee 129.00 Plan Check Fee 32.25 Issue Date Valuation 0 Expiration Date 1/13/08 Qty Unit Charge Per Extension BASE FEE 15.00. 10.00 610000 EA PLB FIXTURE 60.00 1.00 1.5.0000 EA PLB BUILDING SEWER 15.00 LQPERMIT • c Application Number .. . . 07-00002071" Permit . . . . PLUMBING Qty Unit Charge Per Extension 1'.00 7.5000 EA PLB WATER HEATER/VENT 7.50 1.00 3.0000 EA PLB WATER INST/ALT/REP •3.00 1.00 9.0000 EA PLB LAWN SPRINKLER.SYSTEM 9.00 6.00 .7500 EA PLB GAS PIPE >=5 4.50 .1.00 15.0000 EA PLB GAS METER 15.00 Permit GRADING PERMIT Additional desc . Permit Fee . . . . 15.00 Plan'Check Fee .00 Issue Date. Valuation 0 Expiration Date 1/13/08 Qty Unit Charge- Per _ Extension - BASE FEE 15.00 - ---------------------------------------------------------- - Special.Notes and Comments SFD - LOT 69, PLAN 4515C, 1773 SF. WITH 24 SF BOX BAY @ NOOK. PERMIT DOES NOT INCLUDE POOL, SPA, BLOCK WALLS OR DRIVEWAY APPROACH. 2001 CBC, CMC, CPC, 2004 CEC, 2005 ENERGY CODES Other Fees . . ---------------------------------------- . ... ART IN"PUBLIC PLACES -RES 20.00 DIF COMMUNITY CENTERS -RES- 74.00 DIF'CIVIC CENTER - RES 995.00 ENERGY REVIEW FEE 54.76• DIF'FIRE PROTECTION -RES 140.00 GRADING PLAN CHECK FEE .00 DIF LIBRARIES - RES 355.00 DIF PARK MAINT FAC - RES 22.00 DIF PARKS/REC - RES 892.00 ' STRONG MOTION (SMI) - RES 15.73 DIF STREET MAINT FAC -RES 67.00 DIF TRANSPORTATION ' RES 1930.0.0 Fee summary Charged Paid Credited Due Permit Fee. Total ------- 1147.28 .00 ------- --- .00. 1147.28 l Plan Check Total 620.08 .00 .00 620.08 Other Fee Total 4565.49 .00 .00 4565.49 Grand Total 6332.85 .00 .00 6332.85 LQPERMIT JCM Inspections :EM1 39725 Garand Lane Suite F Palm Desert, CA 92211 INSPECTIONS Phone: 760-345-5554 - Fax: 760-772-3895 LLM% INSPECTIONS PRESTRESSED CONCRETE INSPECTION REPORT Date: Project Name: Trilogy @ La Quinta - Shea Homes Project No: 02-1109 Project Address: 60-800 Triolgy Parkway City: La Q-jinta, CA Client: Sub -Contractor: Shea La Quinta, LLC Sun Coast Tensioning General Contractor: Architect: Shea Homes for Active Adults Bassenian Lagoni Structural Engineer: Borm & Associates, Inc./ Suncoast Post Tensi Size and Type of Tendons: 1/2" Diameter Seven Strand Stress -Relieved Tendons Jack Machine Calibration: Received Sheet from Sun Coast -Gage Pressure in psi to Machine Load in kips ry� psi to 33.04 kips/33,000 lbs Calibration Date: Machine # Phasefit L Lot#" �(a Product PlanLJ C r; j e ta: � r���•, �� , ❑✓ IBC ❑ Title 24 Other: Unresolved Items: ❑ None ❑ See Below Description of Work Inspected: Actual Elongation (in) Specified Complies within 7% +/- of specified elongation. Lot# Location Tendons Elongation (in) Reference 11h/SN2. c (p Yes No El El, El y ) � ET, El ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ - ❑ ❑ I hereby certify that I have inspected all of the above work, unless otherwise noted, and to the best of my ability 1 have found this work to comoly with the approved plans, specifications _applicable building laws. Final report issued at project completion. Inspector:,,Ja`ck C. Millin ICC Ceftification No: 0842216-89 Contractor's Representative: Copy 1 JCM Inspections Copy 2 Project Superintendent Copy 3 Governing Agency Page I off JCM Inspections 39725 Garand Lane Suite F •� Palm Desert, CA 92211LT..J INSPECTIONS Phone: 760-345-5554 - Fax: 760-772-3895 INSPECTIONS REINFORCED CONCRETE INSPECTION REPORT Dates: Noted Below Project Name: Project No: Trilogy @ La Quinta - Shea Homes 02-1109 Project Address: City: 60-800 Triolgy Parkway La Quinta, CA Client: Sub -Contractor: Shea La Quinta, LLC DCCCC General Contractor: Architect: Structural Engineer: Shea Homes for Active Adults Bassenian-Lagoni Borm & Associates, Inc./ Suncoast Post Tensi Slump (inches): � Supplier: Superior Time Sampled: ' r-, r., 'N Mix Design: D83625P Time in Mixer (min.): (�� Specified Strength (PSI): 4000 Water Added @ Jobsite (gals.): �� ^ Addmixture: POZZ 322N Concrete Temperature (F): Truck M �� � 1 Ticket #: .:: M -� Ambient Air Temperature (F): C`t (� Field ID Marking: Set A - 4 cylinders ZIBC Title 24 Other: Unresolved Items: None ❑ See Below Location of Sample: CA�� ,, a-� Y �` tn.r, No Samples Taken Description of Work Inspected: Phase G Lot# r,.(,:�C Product Plan qc7C, c" -►�_m 1) Received mill certifications for rebar and tendons placed. 2) Typical exterior Footings including Garage Footings/Door (11,12,13/SD-1), Tie Beams (20/SD-1), Typical Interior Footings/Rib including step (15,18/SD-1), Seven Strand Tendons (4,10,12,13,16/SD-1), Simpson Strong Walls (24/SD-1), Anchor Bolts and Holdowns (6,7,8/SD-1), Pad Footings and additional rebar placed as per these details and as noted on Also, typical details 2, 3/SD-1 and Notes on SN -1 apply. Checked rebar for grade, size, placement, coverage and splices. Rebar and tendons were securely tied and supported off the earth. Accepted for concrete placement. 1) The placement of concrete for areas noted above except Garage Interior Footing and Slab on Grade. Total cubic yards placed: approx A mechanical vibrator was used to consolidate the concrete. Approved #4 rebar slab dowels were placed @ 18" o.c. 2) Molded 4 cylinders for compression tests with breaks at 7 days (1), 28 days (2) and one for holding purposes. ro 1) The placement of concrete for Garage Interior Footings and Slab on Grade Total cubic yards placed: approx 7� Verified correct mix design. I hereby certify that I have inspected all of the above; work, unless otherwise noted, and to the best of my ability I have found this work to comply with the approved plans, specifications _applicable building laws. Final report issued at project completion. Inspector: Jack C. Millin ICC Certification No: 0842216-49 ,%A Contractor's Representative: Copy 1 JCM Inspections Copy 2 Project Superintendent „ Copy 3 Governing Agency Page of r JCM Inspections 39725 Garand Lane Suite F Palm Desert, CA 92211 INSPECTIONS Phone: 760-345-5554 - Fax: 760-772-3895 INSPECTIONS COMPRESSION STRENGTH TEST RESULTS Client: Shea La Quinta, LLC Date: 12/2/07 Project: Trilogy @ La Quinta - Shea Homes Project No: 02-1109 60-800 Triolgy,Parkway La Quinta, CA 92253 Set ID Structure Age 3f Test- Compression Strength JCM ID Location Date Cast Cylinder ID (d3y.$) (psi) Set A Phase 18C1 - Lot #7069 Slab on Grade 273-913 Kitchen 8-13-07 Concrete Required psi: 4000 8024 7 3500 8025 28 4900 8026 28 4950