11-1022 (AR)ra _,{`'iA. P.O. BOX 1504 78-495 CALLE TAMPICO LA QUINTA., CALIFORNIA 92253 Application Number: ==-_11-00001022'�~r.F . Property Address: 81928; -RUSTIC •CANYON DR APN: 764-280-999-69 -300237- Application description: ADDITION - RESIDENTIAL Property Zoning: MEDIUM HIGH DENSITY RES Application valuations 224152 Applicant: PAe r Architect or E PIP Tuv144Q" BUILDING & SAFETY DEPARTMENT .BUILDING PERMIT --------------------------------------------------- LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professionals Code, and my License is in full force and effect. License Class: B 3 License No.: o^83w435�8 De/� tracto. se rOWNER-BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: (_) I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The . Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the ' improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of -proving that he or she did not build or improve for the purpose of sale.). (_ 1. I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.l. (_ 1 I am exempt under Sec. - , B.&P.C. for this reason Date: Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of'perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Name: /wy Lender's Address: /• LQPERMIT VOICE (760) 777-7012 FAX (760) 777-7011 INSPECTIONS (760) 777-7153 Date: 11/03/11 Owner: NOLAN, ROBERT & MARYANN- 81928 RUSTIC CANYON DR LA QUINTA, CA.92253 ( Contractor: KELLNER, JEFFREY F. PO BOX 245 RANCHO MIRAGE, CA.92270 (760)774-5333 Lic. No.: 834358 ------------------ WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. I have and will maintain workers' compensation insurance; as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier STATE FUND' Policy Number 310269700-01 I certify that, in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, if I should become subject to the workers' compensation provisions of Section 3700 of the Labor Code, I shall forthwith comply with those pr 'sion� ire ant: WARNING: FAILURE TO SEC E WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL , SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS 15100,0001. IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the conditions and restrictions set forth on this application. 1. Each person upon whose behalf this application is made, each person at whose request and for whose benefit woik is performed under of pursuant to any permit issued as a result of this application, the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of/county to enter upon the above-mentioned property for ins tion purposes. Date:( /-� _� nature (Applicant or Agent): Application Number . . . . . 11-00001022 . Structure Information Construction Type TYPE V, UNPROTECTED - Occupancy Type . . . . DWELLG/LODGING/CONG <=10 Other struct info.. CODE EDITION 2010 # BEDROOMS 1.00 FLOOD ZONE NO ---------------------------------------------------------------------------- 1ST FLOOR SQUARE FOOTAGE 278.00 Permit . . . ELECT - ADD/ ALT/REM Additional desc . Permit Fee . . . . 43.23 Plan Check Fee 10.81 Issue Date Valuation . . . . 0 Expiration Date 5/01/12 Qty Unit Charge Per Extension BASE FEE. 15.00 278.00 .0350 ELEC NEW RES - 1 OR 2 FAMILY 9.73 1.00 18.5000 ---------------------------------------------------------------------------- EA ELEC SVC <=600V/<=200A 18.50 Permit BUILDING PERMIT INV FEE Additional.desc . Permit Fee . . . . 468.00 Plan Check Fee 152.10 Issue Date Valuation . . 22462 Expiration Date 5%01/12 Qty Unit Charge Per Extension BASE FEE 90.00 21.00 18.0000 -----------.-------------------------,---------------------------------- THOU BLDG 2,001-25,000 378.00 ------ Permit . . . MECHANICAL Additional desc . Permit Fee . . . . 39.50 Plan Check Fee 9.88 Issue Date Valuation . . 0 Expiration Date 5/01/12 Qty Unit Charge Per Extension BASE FEE 15.00 1.00 9.0000'EA MECH FURNACE <=100K 9..00 1.00 9.0000 EA MECH B/C <=3HP/100K BTU 9.00 1.00 6.5000 ---------------------------------------------------------------------------- EA MECH VENT FAN 6.50 Permit PLUMBING INV FEE Additional desc . LQPERMIT Application Number . . . 11-00001022 Permit . . . PLUMBING INV.FEE - Permit Fee 102.00 Plan Check Fee .12.75 Issue Date Valuation 0 .Expiration Date 5/01/12 Qty Unit.Charge Per Extension BASE FEE 30.00 3.00 12.0000 EA PLB FIXTURE 36.00 1.00 30.0000 EA PLB BUILDING SEWER 30.00 1.00 6.0000 EA PLB WATER INST/ALT/REP 6.00 Special Notes and Comments :11/02/2011 - CRC 108.6 -WORK PERFORMED PRIOR TO'OBTAINING PROPER PERMITS. (GROUND PLUMBING,FORMS AND FOOTINGS IN PLACE)''INVESTIGATIVE FEES ASSESSED FOR BUILDING & PLUMBING PERMITS. 278 SF, ATTACHED CASITA ADDITION PER ENGINEERED DESIGN. 2010 CODES. ENGINEER: CARLOS ELIAS #16839. MINOR ADJUSTMENT 2011-629 APPROVED FOR 18 FT FRONT SETBACK. ------------------------- ------------------------.----------------------------------------------------- Other Fees . . . . . BLDG STDS ADMIN (SB1473) -- ---- 2.00 ENERGY REVIEW FEE 15.21 STRONG MOTION (SMI) - RES. 2.25 Fee summary Charged Paid Credited Due Permit Fee. Total 652.73 .00 .00 652.73 Plan Check Total 185.54 .00 .00, 185.54 Other Fee Total 19.46 .00 .00 19.46 Grand Total 857.73 .00 .00 857.73 LQPERMIT 099.1/001 Dint.. ch Quinta.' fit df, La N�Mhig & SafetY.Mdon lermtt # T.O.. $ox.,1504, 78495 Cage-TanjplO. to QuMta, CA 92253 777-7012 Building Permit Application and Tracking Sheet Project Address-. 9.1,9 R-6f.377C, akJ 0 1) owceNim,: A. P. Number Z& -SSD 0 Z(, Add=,. )eUS?7c-- Legw Ddcriptiow. IYAc-e-o 6vr&9 TR 3oo!3-7 Contractor: city.sTzip: L,#ulAl7x _je Add=: dd=: Po. aeg-- "ad D=nphon ADO. C-V,5U7-' C4fl ZA 71) City. ST. Zip: R,4AIC,�(,b . AA-C#gV j-�ekQd A4 4 -- Some Lic, #: 41) r -14.6r City Lk- &v Fie&' Arch.. EW, 1��. j City. ST. Zip: P41-.4 TdThoar- 2 6o 7 740-1 h 2 -wog Type: V Ompancy: $we Lic. 4: Project type (circle one): New Alt. XMC of COW -aa Person: DGA A.) C,+AW-X 0 Sq FtA7.2r 9 Stories: I -T# units j TcIcphwc.# Of Cafta Pemn: 7bo 72,? /&S -,-A- Eaftuated Value of Pwject APPLICANT: 00 NOT WRITE BEiDW THIS UNE Wd TRACK= 'Plan Sw,- Cbe* Utu Amomt "aft for =rrewow I'D 6w rIMCbM&DV.,4t Tr=Cak& COW CwtM Peewee �0 ti Balm Mgt U Cala nm odmd wo phales'amut ed 21! Rtyk-, ra* for co. e KX Sabcqsuctor List COW CMtsd PCFBM GmutD=d Phas pidwd up swu AfftoW "kid "abMftw- IId 11ME- Review, fuoy ft co ftvd"n hwd Fee N=nftAMr*vM Called Quh,t Pen" A.U.P., S&" Ftft 7-v 0 73 If. u • ac(>Cra. Coache~ l� laValley Unified School District 83-733 Avenue 55, Thermal, CA 92274 (760) 398-5909 — Fax (760) 398-1224 This Box For District Use Only .DEVELOPER FEES PAID AREA: AMDUNT - LEVEL ONE AMOUNT: LEVEL TWO AMOUNT: M17-GATION AMOUNT: COMMAND. AMOUNT: DATE: RECEIPT: CHE.CK#: INITIALS: CERTIFICATE OF COMPLIANCE (California Education Code 17620) Project Name:ERY,, Date: november 3, 2011 Owner's Name: Robert Nolan Phone N•). Project Address: 81-928 Rustic Canyon Dr., LaQuintas, CA 92253 Project Description: New attached casita addition APN: 764-550-026 Tract #: Lot #'s: Type of Development: Residential Commercial iXX Industrial Total Square Feet of Building Area: 278 sq. ft. Certification of Applicant/Owi ers: The person signing certifies that the above information is correct and makes this statement under penalty of perjury and further represents that he/she is a Dated: November 3, 2011 Signature: ****************************t-�*********'******************************** SCHOOL DISTRICT'S REQUIREMENTS FOR THE ABOVE PROJECT HAVE BEEN OR WNL BE SATISFIED IN ACCORDANCE WITH ONE OF THE FOLLOWING: (CIRCLE ONE) Education Code. Gov. Code Project 17620 65995 Approval Note: Number of Sq.Ft. 278 sq. ft. Amount per Sq.Ft. $ 0.00 Amount Collected $ 0.00 Building Permit Application Completed: Yes/No By: Jamie T. Brown, Asst. Supt., Business Services Agreement Existing Not Subject to Fee Prior to 1/1/87 Requirement Certificate issued by: Laurie Howard, Secretary HI Signature: NOTICE OF 90 DAY PERIOD FOR PROTEST OF FEES AND STATEMENT OF FEES Section 66020 of the Government Code asserted by Assembly Bill 3081, effective January 1, 1997, requires that this Distr.ct provide (1) a written notice to the project appellant, at the time of payment of school fees, mitigation payment or other exactions ("Fees"), of the 90 -day period to protest the imposition of these Fees and (2) the amount of the fees. Therefore, in accordance with section 66020 of the Government code and other applicable law, this Notice shall serve to advise you that the 90 -day protest period in regard to such Fees or the validity thereof, commences with the payment of :he fees or performance of any other requirements as described in section 66020 of the Government code. Additionally, the amount of the fees imposed is as herein set forth, whether payable at this time or in whole or in part prior to issuance, of a Certificate of Occupancy. As in the latter, the 90 days starts on he date hereof. This Certificate of Compliance is valid for thirty (30) days from the date of issuance. Extension will be granted only for good cause, as determined by the School District, and up to three (3) such extensions may be granted. MV:c,Inydocs/devlees/certi hicatcofcompliance form tablesfO US13.<Ioc 1/16/03T .We are pleased to inform you that your plans for installation of a casita, a low courtyard wall and landscape and :irrigation modifications after casita is completed, received on 08/09/2011, have been approved by the Architectural Committee with the following conditions: 7, 8, 9,1;1,13,15,16,18,19 and 23. Please refer to HOA guidelines section V. Site Development, 5.2, (z), (i) Attached or Detached Dwellings: Front elevation must match existing structure, provide drainage thru wall in SVSB. Please note: Any, damages caused by contractor due to construction must be repaired; all irrigation and landscape'shall be restored to original condition: This approval does not constitute consent by the Association for the applicant to encroach, trespass, or build on any property other than .that of the applicant. This approval is related solely to the items reserved for approval by the CC&R's in accordance with the Architectural Guidelines. The approval does not extend to the. .quality of work done by your architect, or contractor; or to any structural engineering, soils engineering, or site grading and drainage design. You are urged to obtain the services of a state licensed professional for consultation as needed.. The Architectural Committee is composed of volunteers. As such, it does not review applications to ensure .compliance with building codes, or other local or state laws. Please be advised that this approval does not relieve you from obtaining any necessary building permits from the governmental agencies involved to ensure compliance with these codes.. Any violations of these ordinances will be your responsibility to correct. Thank you for your patience in this matter and for complying with the Association's policies and. standards. , rely, o the tural Committee arty Ste tt, CCAM, CMCA, AMS Comm ty Manager Enclosures cc: - Board of Directors Architectural Committee Trilogy at t a`Quinta Maintenance Assoc.. Projessionally�"lyfomiggeil by Action Property Management, Inc: 60-750 trilbgy Parkway, LaQuinta, CA 92253-7717 Phone: -760-777059 Fax: (760) 564-2474 www.actionlife.com sl a Trilog, August 10, 2.011 Robert Nolan Maryann Nolan 36 Catalina Dr Sherwood Park, AB T8H 1R2 - CANADA Property: 81928 Rustic Canyon Dr Account: 015000020960 CONDITIONAL APPROVED Dear Robert Nolan: .We are pleased to inform you that your plans for installation of a casita, a low courtyard wall and landscape and :irrigation modifications after casita is completed, received on 08/09/2011, have been approved by the Architectural Committee with the following conditions: 7, 8, 9,1;1,13,15,16,18,19 and 23. Please refer to HOA guidelines section V. Site Development, 5.2, (z), (i) Attached or Detached Dwellings: Front elevation must match existing structure, provide drainage thru wall in SVSB. Please note: Any, damages caused by contractor due to construction must be repaired; all irrigation and landscape'shall be restored to original condition: This approval does not constitute consent by the Association for the applicant to encroach, trespass, or build on any property other than .that of the applicant. This approval is related solely to the items reserved for approval by the CC&R's in accordance with the Architectural Guidelines. The approval does not extend to the. .quality of work done by your architect, or contractor; or to any structural engineering, soils engineering, or site grading and drainage design. You are urged to obtain the services of a state licensed professional for consultation as needed.. The Architectural Committee is composed of volunteers. As such, it does not review applications to ensure .compliance with building codes, or other local or state laws. Please be advised that this approval does not relieve you from obtaining any necessary building permits from the governmental agencies involved to ensure compliance with these codes.. Any violations of these ordinances will be your responsibility to correct. Thank you for your patience in this matter and for complying with the Association's policies and. standards. , rely, o the tural Committee arty Ste tt, CCAM, CMCA, AMS Comm ty Manager Enclosures cc: - Board of Directors Architectural Committee Trilogy at t a`Quinta Maintenance Assoc.. Projessionally�"lyfomiggeil by Action Property Management, Inc: 60-750 trilbgy Parkway, LaQuinta, CA 92253-7717 Phone: -760-777059 Fax: (760) 564-2474 www.actionlife.com sl This Material Sent for: ❑ Your Files ® Per Your Request CIF1IAW�+ ❑ Your Review ❑ Approval ❑ Checking ❑ At the request of:ft ry v -T �r2 nn 1�rr'r— Other: ❑ By: John W. Thompson Rancho Mirage Office: ® (760) 834-8860 Other: ❑ 686 71..780 San Jacinto Dr:. Ste: E2- Rancho Mirage `Ca,. 92270 ph (76Q) 834-8860: —fax 834-8861 Letter of Transmittal To: City of La Quinta Today's Date: 10-31-11 78-495 Calle Tampico City Due Date: 11-1-11 La Quinta, CA 92253 Project Address: 81-928 Rustic Canyon Attn: Kay Plan Check #: 11-1022 Submittal: ❑ 1st ❑ 4th ® 2nd ❑ 5th ❑ 3`d ❑ Other: We are forwarding: ® By Messenger ❑ By Mail (Fed Ex or UPS) ❑ Your Pickup Includes: # Of Descriptions: Includes: # Of Descriptions: Copies: Copies: ❑ Structural Plans ® 1 Revised Structural Plans ❑ Structural Calculations ® 1 Revised Struct. Calcs ® 1 Truss Calculations ❑ Revised Truss ❑ Soils Report ❑ Revised Soils Report ® 1 Structural Comment List ❑ Appro,.ed Structural Plans ® Redlined Structural Plans ❑ Approved Structural Calcs ® 1 Redlined Structural Calcs ❑ Approved Truss Calcs ❑ Redlined Truss Calcs ❑ Approved Soils Report ❑ Redlined Soils Reports ❑ Other: Comments: Structural content is approvable; pending engineer of record provide a review/approved letter for the truss calculations or stamp truss calculations with a reviewed/approved shop drawing stamp. This Material Sent for: ❑ Your Files ® Per Your Request CIF1IAW�+ ❑ Your Review ❑ Approval ❑ Checking ❑ At the request of:ft ry v -T �r2 nn 1�rr'r— Other: ❑ By: John W. Thompson Rancho Mirage Office: ® (760) 834-8860 Other: ❑ � ,a BUILDING ENERGY ANALYSIS REPORT PROJECT: Nolan Residence 81928 Rustic Canyon Drive La Quinta, CA Project Designer: 0 V3 Report Prepared by: Joan D. Hacker Insu-form, Inc. 77-810 Las Montanas Road, Suite 201 ` Palm Desert, Ca 92211 760--3451352 F� 0 T SEP 2 1 2011 By I.) .l Job Number: CITY OF LA QUINTA BUILDING & SAFETY DEPT, APPROVED Date: FOR CONSTRUCTION 9/12/2011 DAT a ►� Br The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2008 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC — www.energysoft.com. EnergyPro 5.1 by Ener Soft User Number. 2655 Run Code: 2011-09-12T18:02:53 /D r e TABLE OF CONTENTS Cover Page 1 Table of Contents 2 Form CF -1 R Certificate of Compliance 3 Form MF -1 R Mandatory Measures Summary 8 HVAC System Heating and Cooling Loads Summary, 11 PERFORMANCE CERTIFICATE: Residential Part 1 of 5 CF-1 R Project Name Nolan Residence Building Type ® Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 9/1212011 Project Address 81928 Rustic Canyon Drive La Quinta California Energy Climate Zone CA Climate Zone 15 Total Cond. Floor Area 278 Addition n/a # of Stories 1 FIELD INSPECTION ENERGY CHECKLIST ❑ Yes El No HERS Measures -- If Yes, A CF-4R must be provided per Part 2 of 5 of this form. ® Yes ❑ No Special Features -- If Yes, see Part 2 of 5 of this form for detai=s. INSULATION Area Special Construction Type Cavity Features see Part 2 of 5 Status Wall Wood Framed R-13 140 New Wall Wood Framed R-19 482 New Roof Wood Framed Attic R-38 278 New Slab Unheated Slab-on-Grade None 278 Perim = 15' New FENESTRATION U- Exterior Orientation Area Factor SHGC Overhang Sidefins Shades Status Front (S) 10.0 0.710 0.73 2.0 none Bug Screen New Front (S) 10.0 0.710 0.73 2.0 none Bug Screen New Left (W) 24.0 0.710 0.73 2.0 none Bug Screen New Rear (N) 6.0 0.710 0.73 2.0 none Bug Screen New HVAC SYSTEMS City. Heating Min. Eff Cooling Min. Eff Thermostat Status 1 Room Heat Pump 6.59 COP Room PTAC without Sic 12.0 EER Setback New HVAC DISTRIBUTION Duct Location Heating Cooling Duct Location R-Value Status Casita Ductless / with Fan Ductless n/a n/a New WATER HEATING City. Type Gallons Min. Eff Distribution Status 1 Instant Gas 0 0.83 No Pipe Insulation New EnergyPro 5.1 by Energ Soft User Number. 2655 RunCode: 2011-09-12718:02:53 ID: Pa e 3 of 11 PERFORMANCE CERTIFICATE: Residential Part 2 of 5 CF -1 R Project Name Nolan Residence Building Type ® Single Family ❑ Addition Alone 1 ❑ Multi Family ❑ Existing+ Addit orVAlteration Date 1911212011 SPECIAL FEATURES INSPECTION CHECKLIST The enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies: based on the adequacy of the special justification and documentation submitted. ' HIGH MASS Design - Verify Thermal Mass: 278.0 & Exposed Slab Floor, 3.500' thick at Casita HERS REQUIRED VERIFICATION Items in this section require field testing and/or verification by a certified HERS Rater. The inspector must receive a completed CF -413 form for each of the measures listed below for final to be given. EnemvPro 5.1 by Ener Soft User Number. 2655 Run Code: 2011-09-12718:02:53 ID: Pace 4 of 11 PERFORMANCE CERTIFICATE: Residential Part :3 of 5 CF-1 R Project Name Building Type m Single Family ❑ Addition Alone Date Nolan Residence 1 ❑ Multi Family ❑ Existing+ Addition/Alteration 1911212011 ANNUAL ENERGY USE SUMMARY Standard Proposed Margin TDV kBtu/ft2- r Space Heating 1.05 0.95 0.10 Space Cooling 104.92 93.54 11.38 Fans 19.13 25.58 -6.45 Domestic Hot Water 75.70 36.85 38.85 Pumps 0.00 0.00 0.00 Totals 200.79 156.91 43.88 Percent Better Than Standard: 21.9 BUILDING COMPLIES - NO HERS VERIFICATION REQUIRED Fenestration Building Front Orientation:' (S) 180 deg Ext. Walls/Roof Wall Area Area Number of Dwelling Units: 1.00 (S) 160 20 Fuel Available at Site: Natural Gas (M/) 176 24 Raised Floor Area: 0 (N) 160 6 Slab on Grade Area: 278 (E) 176 0 Average Ceiling Height: 8.0 Roof 278 0 Fenestration Average U-Factor: 0.71 TOTAL: 50 Average SHGC: 0.73 Fenestration/CFA. Ratio: 18.0% REMARKS STATEMENT OF COMPLIANCE This certificate of compliance lists the building features and specifications needed to comply with Title 24, Parts 1 the Administrative Regulations and Part 6 the Efficiency Standards of the California Code of Regulations. The documentation author hereby certifies that the documentation is accurate and complete. Documentation Author Company Insu-form, Inc. 9/12/2011 Address 77-810 Las Montanas Road, Suite 201 Name Joan D. Hacker City/State/ZipCity/State/Zip Palm Desert, Ca 92211 Phone 760-345-1352 Signed Date The individual with overall design responsibility hereby certifies that the proposed building design represented in this set of construction documents is consistent with the other compliance forms and worksheets, with the specifications, and with any other calculations submitted with this permit application, and recognizes that compliance using duct design, duct sealing, verification of refrigerant charge, insulation installation quality, and building envelope sealing require installer testing and certification and field verification by an approved HERS rater. Designer or Owner (per Business & Professions Code) Company Address Dean Carlson Name 2125 N. Girasol Avenut City/State/ZipPalm Springs, CA 9226% Phone Signed License# Date EnerovPro 5.1 by EnemySoff User Number: 2655 Run Code: 2011-09-12718:02:53 ID: Pace 5 of 11 CERTIFICATE OF COMPLIANCE: Residential Part 4 of 5)_ CF -1 R Project Name Nolan Residence Building Type ® Single Family ❑ Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 1911212011 OPAQUE SURFACE DETAILS Surface U- Insulation Joint Appenc:ix TvDe Area I Factor Exterior Frame Interior Frame Azm Tilt Status 4 Location/Comments Wall 140 0.102 180 90 New 4.3.1-A3 Casita Wall 152 0.074 270 90 New 4.3.1-A5 Casita ER-19 Wall 154 0.074 0 90 New 4.3.1-A5 Casita Wall 176 0.074 90 90 New 4.3.1-A5 Casita Root 278 0.025 R-38 180 0 New 4.2.1-A21 Casita Slab 278 0.730 None 0 180 New 4.4.7-A1 Casita FENESTRATION SURFACE DETAILS ID Tvoe Area U -Factor SHGC2 Azm Status Glazing Type Location/Comments 1 Window 10.0 0.710 Default 0.73 Default 180 New Double Metal Clear Casite 2 Window 10.0 0.710 Default 0.73 Default 180 New Double Metal Clear Casita 3 Window 24.0 0.710 Default 0.73 Default 270 New Double Metal Clear Casita 4 Window 6.0 0.710 Default 0.73 Default 0 New Double Metal Clear Casita (1) Ll -Factor Type: 116-A = Default Table from Standards, NFRC = Labeled Value 2 SHGC Type: 116-B = Default Table from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAILS Window Ove hanq Left Fin Right Fin ID Exterior Shade T e SHGC Hot Wd I Len I H t LExt I REA Dist I Len Hat Dist I Len Hot 1 Bug Screen 0.76 5.0 2.0 2.01 0.1 2.01 2.0 2 Bug Screen 0.76 5.0 2.0 2.0 0.1 2.01 2.0 3 Bug Screen 0.76 8.0 3.0 2.0 0.1 2.01 2.0 4 lBug Screen 0.76 3.0 2.0 2.0 0.1 2.0 2.0 Ener Pro 5.1 by EnergySoff User Number. 2655 RunCode: 2011-09-12718:02:53 ID: Page 6 of 11 CERTIFICATE OF COMPLIANCE: Residential Part 5 of 5 CF -1 R Project Name Nolan Residence Building. Type ® Single Family ❑ Addition Alone: ❑ Multi Family ❑ Existing+ Addi-Jon/Alteration Date 1911212011 BUILDING ZONE INFORMATION System Name Zone Name Floor Area New Existing Altered I Removed Volume Year Built Casita Casita 278 2,224 1996 Totals 01 278 01 0 HVAC SYSTEMS S stem Name Qty. HeatingType Min. Eff. CoolingType Min. Eff. Thermostat T e Status Casita 1 Room Heat Pump 6.59 COP Room PTAC without Sidi 12.0 EER Setback New HVAC DISTRIBUTION System Name Heating Duct Cooling Duct Location R -Vague Ducts Tested? Status Casita Ductless / with Fan Ductless n/a n/a ❑ New 13 WATER HEATING SYSTEMS S stem Name aty. Type Distribution Rated Input Btuh Tank Cap. al Energy Standby Factor Loss or or RE Pilot Ext. Tank Insul. R- Value Status Takagi T -K3 -Pro 1 Instant Gas No Pipe Insulation 199,000 0 0.83 n/a We New MULTI -FAMILY WATER HEATING DETAILS I HYDRONIC HEATING SYSTEM PIPING Control Hot Water Piping Length h c Q c System Name Pipe Length Pipe Diameter Insul. Thick. Ot . HP Plenum Outside Buried 01 ❑ EnergyPro 5.1 by EnergySoft User Number: 2655 RunCode: 2011-09-12T18:02:53 ID: Page 7 of 11 MANDATORY MEASURES SUMMARY: Residential Pae 1 of 3 MF -1 R Project Name Nolan Residence Date 1 9/12/2011 NOTE: Low-rise residential buildings subject to the Standards must comply with all applicable mandatory neasures listed, regardless of the compliance approach used. More stringent energy measures listed on the Certificate of Compliance (OF -1 R, CF -1 R -ADD, or CF - 1 R -ALT Form) shall supersede the items marked with an asterisk (') below. This Mandatory Measures Summary shall be incorporated into the permit documents, and the applicable features shall be considered by all parties as minimum component performance specifications whether they are shown elsewhere in the documents or in this summary. Submit all applicable sections of the MF -1 R Form with plans. Building Envelope Measures: 116(a)l: Doors and windows between conditioned and unconditioned spaces are manufactured to limit a$ leakage. §116(a)4: Fenestration products (except field -fabricated windows) have a label listing the certified 1.1 -Factor, certified Solar Heat Gain Coefficient SHGC and infiltration that meets the requirements of 10-111 (a). 117: Exterior doors and windows are weather-stripped; all joints and penetrations are caulked and sealed. 118(a): Insulationspecified or installed meets Standards for Insulating Material. Indicate type and include on CF -6R Form. §118(i): The thermal emittance and solar reflectance values of the cool roofing material meets the requirenents of §118(1) when the installation of a Cool Roof is specified on the CF -1 R Form. *§1 50 a : Minimum R-19 insulation in wood -frame ceiling or equivalent LI -factor. 4150(b): Loose fill insulation shall conform with manufacturer's installed design labeled R -Value. *§150(c): Minimum R-13 insulation in wood -frame wall orequivalent 1.1 -factor. *§1 Od : Minimum R-13 insulation in raised wood -frame floor or equivalent 1.1 -factor. 4150(f): Air retardina wrap is tested labeled and installed according to ASTM E1677-95 2000 when specified on the CF -1 R Form. 150 : Mandatory Vapor barrier installed in Climate Zones 14 or 16. §150(1): Water absorption rate for slab edge insulation material alone without facings is no greater than 0.3%; water vapor permeance rate is no greater than 2.0 permAnch and shall be protected from physical damage and UV light deterioration. Fireplaces; Decorative Gas Appliances and Gas Log Measures: 150 e 1 A: Masonry or factory -built fireplaces have a closable metal or glass door covering the entire opening. of the firebox. §150(e)1 B: Masonry or factory -built fireplaces have a combustion outside air intake, which is at least six square inches in area and is equipped with a with a readily accessible operable, and tight -fitting damper and or a combustion -air control device. §150(e)2: Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the outside of the building,are prohibited. Space Conditioning, Water Heating and Plumbing System Measures: §110-§113: HVAC equipment, water heaters, showerheads, faucets and all other regulated appliances are certified by the Energy Commission. §113(c)5: Water heating recirculation loops serving multiple dwelling units and High -Rise residential occupancies meet the air release valve backflow prevention, pumpisolation valve and recirculation loop connection requirements of §113:5. §115: Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces, household cooking appliances (appliances with an electrical supply voltage connection with pilot lights that consume less than 150 Btu/hr are exempt), and pool and spa heaters. 150(h): Heating and/or cooling loads are calculated in accordance with ASHRAE, SMACNA or ACCA. §150(i): Heating systems are equipped with thermostats that meet the setback requirements of Section 112(c). §1500)tA: Storage gas water heaters rated with an Energy Factor no greater than the federal minimal stasidard are externally wrapped with insulation having an installed thermal resistance of R-12 or greater. §1500)1 B: Unfired storage tanks, such as storage tanks or backup tanks for solar water -heating system, or other indirect hot water tanks have R-12 external insulation or R-16 internal insulation where the internal insulation R -value is indicated on the exterior of the tank. §1500)2: First 5 feet of hot and cold water pipes closest to water heater tank, non -recirculating systems, and entire length of recirculating sections of hot water pipes are insulated per Standards Table 150-B. §1500)2: Cooling system piping (suction, chilled water, or brine lines),and piping insulated between heating source and indirect hot water tank shall be insulated to Table 150-B and Equation 150-A. §1500)2: Pipe insulation for steam hydronic heating systems or hot water systems >15 psi, meets the requirements of Standards Table 123-A. §1500)3A: Insulation is protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind. §1500)3A: Insulation for chilled water piping and refrigerant suction lines includes a vapor retardant or is enclosed entirely in conditioned space. §1500)4: Solar water -heating systems and/or collectors are certified by the Solar Rating and Certification Corporation. EnergyPro 5.1 by EnergySoR User Number. 2655 Run Code: 2011-09-12T18:02:53 ID: Page 8 o/ 11 MANDATORY MEASURES SUMMARY: Residential (Page 2 of 3 MF -1 R Project Name Date 912/201 Nolan Residence §150(m)1: All air -distribution system ducts and plenums installed, are sealed and insulated to meet the requirements of CMC Sections 601, 602, 603, 604, 605 and Standard 6-5; supply -air and return -air ducts and plenums are insulated to a minimum installed level of R- 4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct -closure system that meets the applicable requirements of UL 181, UL 181 A, or UL 181 B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings reater than 1/4 inch the combination of mastic and either mesh or tape shall be used §150(m)1: Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area of the ducts. §150(m)2D: Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such tape is used in combination with mastic and draw bands. 1 50 m 7: Exhaust fans stems have back draft or automatic dampers. §150(m)8: Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated dampers. §150(m)9: Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that can cause dearadation of the material. 150 m 10: Flexible ducts cannot have porous inner cores. §150(o): All dwelling units shall meet the requirements of ANSI/ASHRAE Standard 62.2-2007 Ventilation and Acceptable Indoor Air Quality in Low -Rise Residential Buildings. Window operation is not a permissible method of providing the Whole Building Ventilation required in Section 4 of that Standard. Pool and Spa Heating Systems and Equipment Measures: §114(a): Any pool or spa heating system shall be certified to have: a thermal efficiency that complies with the Appliance Efficiency Regulations; an on-off switch mounted outside of the heater; a permanent weatherproof plate or card with operating instructions; and shall not use electric resistance heating ora pilot light. §114(b)1: Any pool or spa heating equipment shall be installed with at least 36" of pipe between filter and heater, or dedicated suction and return lines or built-up connections for future solar heatin . 114(b)2: Outdoor pools ors as that have a heat pump or gas heater shall have a cover. §114(b)3: Pools shall have directional inlets that adequately mix the pool water, and a time switch that will allow all pumps to be set or programmed to run only during off-peak electric demand periods. 150 : Residential pool systems or equipment meet the pump sizing, flow rate, piping, filters, and valve requirements of §150 Residential Lighting Measures: §150(k)1: High efficacy luminaires or LED Light Engine with Integral Heat Sink has an efficacy that is no lower than the efficacies contained in Table 150-C and is not a low efficacy luminaire asspecified by §150(k)2. §150(k)3: The wattage of permanently installed luminaires shall be determined asspecified by §130(d). §150(k)4: Ballasts for fluorescent lamps rated 13 Watts or greater shall be electronic and shall have an output frequency no less than 20 kHz. §150(k)5: Permanently installed night lights and night lights integral to a permanently installed luminaire or exhaust fan shall contain only high efficacy lamps meeting the minimum efficacies contained in Table 150-C and shall not contain a line -voltage socket or line - voltage lamp holder; OR shall be rated to consume no more than five watts of power as determined by §130(d), and shall not contain a medium screw -base socket. 4150(k)6: Lighting integral to exhaust fans in rooms other than kitchens, shall meet the applicable requirements of §150(k). 150(k)7: All switchingdevices and controls shall meet the requirements of4150(k)7. §150(k)8: A minimum of 50 percent of the total rated wattage of permanently installed lighting in kitchens shall be high efficacy. EXCEPTION: Up to 50 watts for dwelling units less than or equal to 2,500 ft2 or 100 watts for dwelling units larger than 2,500 ft2 may be exempt from the 50% high efficacy requirement when: all low efficacy luminaires in the kitchen are controlled by a manual on occupant sensor, dimmer, energy management system (EMCS), or a multi -scene programmable control system; and all permanently installed luminaries in garages, laundry rooms, closets greater than 70 square feet, and utility rooms are high efficacy and controlled by a manual -on occupant sensor. §150(k)9: Permanently installed lighting that is internal to cabinets shall use no more than 20 watts of power per linear foot of illuminated cabinet. EnergyPro 5.1 by EnergySoft User Number. 2655 RunCode: 2011-09-12T18:02:53 ID: Page 9 of 11 MANDATORY MEASURES SUMMARY: Residential (Page 3 of 3 MF-1 R Project Name Date 9/12/2011 Nolan Residence §150(k)l0: Permanently installed luminaires in bathrooms, attached and detached garages, laundry rooms, closets and utility rooms shall be high efficacy. EXCEPTION 1: Permanently installed low efficacy luminaires shall be allowed provided that they are controlled by a manual-on occupant sensor certified to comply with the applicable requirements of §119. EXCEPTION 2: Permanently installed low efficacy luminaires in closets less than 70 square feet are not required to be controlled by a manual-on occupancy sensor. §150(k)11: Permanently installed luminaires located in rooms or areas other than in kitchens, bathrooms, garages, laundry rooms, closets, and utility rooms shall be high efficacy luimnaires. EXCEPTION 1: Permanently installed low efficacy luminaires shall be allowed provided they are controlled by either a dimmer switch that complies with the applicable requirements of §119, or by a manual- on occupant sensor that complies with the applicable requirements of §119. EXCEPTION 2: Lighting in detached storage building less than 1000 square feet located on a residential site is not required to comply with §150 k 11. §150(k)l2: Luminaires recessed into insulated ceilings shall be listed for zero clearance insulation contact (IC) by Underwriters Laboratories or other nationally recognized testing/rating laboratory; and have a label that certifies the lumiunaire is airtight with air leakage less then 2.0 CFM at 75 Pascals when tested in accordance with ASTM E283; and be sealed with a gasket or caulk between the luminaire housing and ceiling. §150(k)l3: Luminaires providing outdoor lighting, including lighting for private patios in low-rise residential buildings with four or more dwelling units, entrances, balconies, and porches, which are permanently mounted to a residential building or to other buildings on the same lot shall be high efficacy. EXCEPTION 1: Permanently installed outdoor low efficacy luminaires shall be allowed provided that they are controlled by a manual on/off switch, a motion sensor not having an override or bypass switch that disables the motion sensor, and one of the following controls: a photocontrol not having an override or bypass switch that disables the photocontrol; OR an astronomical time clock not having an override or bypass switch that disables the astronomical time clock; OR an energy management control system (EMCS) not.having an override or bypass switch that allows the luminaire to be always on EXCEPTION 2: Outdoor luminaires used to comply with Exceptionl to §150(k)13 may be controlled by a temporary override switch which bypasses the motion sensing function provided that the motion sensor is automatically reactivated within six hours. EXCEPTION 3: Permanently installed luminaires in or around swimming pool, water features, or other location subject to Article 680 of the California Electric Code need not be hi h efficacy luminaires. §150(k)14: Internally illuminated address signs shall comply with Section 148; OR not contain a screw-base socket, and consume no more than five watts of power as determined according to §130(d). §150(k)15: Lighting for parking lots and carports with a total of for 8 or more vehicles per site shall comply with the applicable requirements in Sections 130, 132, 134, and 147. Lighting for parking garages for 8 or more vehicles shall comply with the applicable requirements of Sections 130,131, 134 and 146. §150(k)l6: Permanently installed lighting in the enclosed, non-dwelling spaces of low-rise residential buildings with- four or more dwelling units shall be high efficacy luminaires. EXCEPTION: Permanently installed low efficacy luminaires shall be allowed provided that they are controlled by an occupant sensors certified to comply with the applicable requirements of § 119. EnergyPro 5.1 by EnefgySoR User Number: 2655 RunCode: 2011-09-12T18:02:53 ID: Page 10 of 11 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name Nolan Residence Date 9/12/2011 System Name Casita Floor Area 278 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation F Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL CFM 340 0 COOLING PEAK COIL HTG. PEAK Sensible Latent CFM Sensible Heating System Output per System 15,100 7,243 605 137 5,118 Total Output Btuh 15,100 0 Output Btuh/ ft 54.3 0 0 Cooling System 0 0 Output per System 17,500 0 0 0 0 Total Output Btuh 17,500 0 0 7,243 605 0 0 Total Output ons 1.5 Total Output Btuh/s ft 62.9 5,118 Total Output s ft/Ton 190.6 Air System CFM per System 300 HVAC EQUIPMENT SELECTION Airflow cfm 300 Samsung 052/070 13,038 1,815 9,431 1 9,431 Jan 1 AM Airflow cfm/s ft 1.08 Airflow cfmfTon 205.7 Outside Air % 0.0% Total Adjusted System Output (Adjusted for Peak Design conditions) I TIME OF SYSTEM PEAK 1 13,0381 1,815 Aug 3 PM Outside Air cfm/s ft 0.00 Note: values above given at ARI conditions HEATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26 OF 70 OF 0 Outside Air 0 cfm Supply Fan 300 cfm 70 OF 41 70 OF 105 OF Heating Coil 105 OF - ROOM 70 OF COOLING SYSTEM PSYCHROMETICS Airstream Temperatures at Time of Cooling Peak 112/78°F 75/62°F 75/62°F 55/54°F O C Outside Air 0 cfm Supply Fan Cooling Coil 300 cfm 75 / 62 OF r 55/ 54 OF 48.6% ROOM 75/ 62 OF EnergyPro 5.1 by EnergySoR User Number. 2655 RunCode: 2011-09-12T18:02:53 /D: Page 11 of 11