Loading...
BPLB2016-013778-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 Titr444g!Arw DESIGN & DEVELOPMENT DEPARTMENT BUILDING PERMIT VOICE (760) 777-7125 FAX (760) 777-7011 INSPECTIONS (760) 777-7153 Application Number: BPLB2016-0137 Owner: Property Address: 47610 EISENHOWER DR 4 . ® OBERT HATFIELD APN: 646150025 Q 0 BOX 750 Application Description: HATFIELD RESIDENCE / HOT WA H R QUINTA, CA 92253 Property Zoning: v 7 0 2016 Application Valuation: $4,525.00 DEC 1 Applicant: QUINTA IE INC 31225 LA BAYA WESTLAKE VILLAGE, CA 91362 Date: 12/6/2016 CIT( QF LA tractor: DESIGN AND DEVELOPMENT DEPARTMrL SEASONS AIR CONDITIONING PLUMBING & 75-450 GERALD FORD DR STE 303 PALM DESERT, CA 92211 LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, and my License is in full force and effect. License Class: C20, C36 License No.: 827420 Date )Z 'l h,L _Contractor: OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that 1 am exempt from the Contractor's State License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: (_) I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). (_) I, as owner of the property, am exclusively contracting with licensed contractors to construct the project. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). (_) I am exempt under Sec. . B.&P.C. for this reason Date: Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Name: Lender's (760)202-3067 Llc. No.: 827420 WORKER'S COMPENSATION DECLARATION hereby affirm under penalty of perjury one of the following declarations: I have and will maintain a certificate of consent to self -insure for workers' :ompensation, as provided for by Section 3700 of the Labor Code, for the performance :)f the work for which this permit is issued. �M� I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier: SECURITY NATIONAL INSURANCE COMPANY Policy Number: SWC1104S44 I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, if I should become subject to the workers' compensation provisions of Section 3700 of the Labor Code, I shall forthwith comply with those provisions. Date: 174-11 tt p Applicant: WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT: Application is hereby made to the Building Official for a permit subject to the conditions and restrictions set forth on this application. 1. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application , the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents, and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter upon the above-mentioned property for inspection purposes. o Dater l tle Signature (Applicant or Agent) ' Date: 12/6/2016 Application Number: 6131-132016-0137 Owner: Property Address: 47610 EISENHOWER DR ROBERT HATFIELD APN: 646150025 P 0 BOX 750 Application Description: HATFIELD RESIDENCE / HOT WATER HEATER LA QUINTA, CA 92253 Property Zoning: Application Valuation: $4,525.00 Applicant: Contractor: IE INC ALL SEASONS AIR CONDITIONING PLUMBING & 31225 LA BAYA 75-450 GERALD FORD DR STE 303 WESTLAKE VILLAGE, CA 91362 PALM DESERT, CA 92211 (760)202-3067 Llc. No.: 827420 --------------------------------------------------------------------------------------------- Detail: INSTALL TANKLESS WATER HEATER [2013 ENERGY] CARBON MONOXIDE ALARM(S) TO BE INSTALLED PRIOR TO FINAL INSPECTION. PER 2013 CALIFORNIA BUILDING CODES DESCRIPTION - FINANCIAL INFORMATION ACCOUNT QTY AMOUNT BSAS SB1473 FEE 101-0000-20306 0 $1.00 Total Paid for BUILDING STANDARDS ADMINISTRATION BSA: $1.00 DESCRIPTION ACCOUNT QTY AMOUNT PERMIT ISSUANCE • 101-0000-42404 0 $96.27 Total Paid for PERMIT ISSUANCE: $96.27 DESCRIPTION ACCOUNT QTY AMOUNT WATER HEATER/VENT 101-0000-42401 0 $12.67 DESCRIPTION ACCOUNT QTY AMOUNT WATER HEATER/VENT PC 101-0000-42600 0 $7.60 Total Paid for PLUMBING FEES: $20.27 Bin.# Cit0� Quo: Building a Safety Division P.O. Box 1504,78-495 Calle Tampico 14.Quinta, CA 92253 - (760) 777-7012 Building Permit Application and Tracking Sheet Permit # Project Address: 47610 Eisenhower Drive Owner's Name:. Kathy Hatfield A. P. Number. Address: 47610 Eisenhower Drive Legal Description: Contractor. All Seasons A%C, Plumbing & Heating City, ST, Zip; La Quinta, CA .92253 Telephone: Address: 73605 Dinah Shore Drive #1310M Project Description: Remove existing storage water heater and. City, ST, Zip: Palm Desert, CA 92211 replace with new Navien NPE 210A tankless water heater . Telephone: 760-568-2663 State Lic. # : 827420. City Lic, 9. Arch., Engr., Designer Address: City, ST. Zap: Telephone:. State Lit:. #: ,i :'"✓n�•'.f. 3 r aF� Construction Type: . Occupancy: Project type (circle one): New Add'n Alter Repair Demo Sq. Ft.: # Stories: # Units: Name of Contact Person: Steven Schnierer Telephone # of Contact Person: 8.18-735-7876 Estimated Vafue of Project: 4,525.00. APPLICANT: DO NOT WRITE BELOW THIS UNE # Submittal Req'd Recd TRACMG PERMfF FEES Plan Sets Pian Check submitted Item Amount Structural Cales. Reviewed, ready for corrections Plan Check Deposit. . Truss Cates. Called Contact Person Plan Check Balance Title 24 Calci. Plans picked up Construction Flood plain plan Plans resubmitted Mechanical Grading pled 2" Review, ready for correctionslissue Electrical Subeontactor List Called CoutactPerson Plumbing Grant Deed Plans picked up S.M.I. H.O.A. Approval Plans resubmitted Grading IN HOUSE.- '^' Review; ready for correetionslissae Developer Impact Fee Planning Approval Called Contact Person A.I.P.P. Pub. Wks. Appr ' Date of permit Issue School Fees Total Permit Fees STATE OF CALIFORNIA' RESIDENTIAL ALTERATIONS -WATER HEATER CEC-CFIR-ALTRI-E (Revised 06114) CALIFORNIA ENERGY COMMISSION CERTIFICATE OF COMPLIANCE CF1R-ALT-01-E WATER HEATER Prescriptive Residential Alterations for Water Heater (Page 1 o 2) A. GENERAL -INFORMATION - 01 Site address, Building Type: ngle Family Dwelling . o Multi Family Dwellings City,, Zip Code: Lq Outvkvm.GA% tizzy Climate Zone: 06 G. WATER HEATING SYSTEMS Section 160.2(b)1G) 01 02 1 03 04 1 05 06 07 08 09 10 11 1a 13 14 15 Water Water Water' • N of . Water Fuel Rated Rated Heating Heating Standby Exterlor Back -Up Central Dwelling Heating Heating 'Heater Water Heater Type Input Input Efficiency EfFlC)ency Loss'(%) insult Solar DIM System unit DHW System System Type Heaters Storage Type Value Type Value R. -.Value Savings Distribution System Identification • Type in Volume Frattion Type Distribution br. system - (gal) . Type Name Plaviex, Di4w zy s+.1 F . NIA. RO,3601 UE IF e qU PA, IN 1A A N A S+rca�d�rtil N?r--2)peA .. .. , WATER HEATING SYSTEMS Water heating cortipliance for'an alteration Is described InSection 150.2(b)1G. For single dwell(ng'a.gas yr propane Water heater, with a'storage tank of -60 gallons maximum br instantaneous (tankless) can be. used. Dwelling Unit distribution systems areJlmited to Standard trunk and branch -or demand recirculaflon for gas or propane,water �gater..Demartd recirculation isnot allowed for electric water heater. If there is no natural-gas. connected to the building, an e.[RctrJc waterheater, may hk replaced with another electric water heater.. However, rhangingfrom gas to electric is not allowed. Multi-famliy central systems must use certified equi.prt,ent;as defined,urider Section 1163 and Ti0:3. NOTE: If the proposed Installation -does not meet the requirements allowed specifically for alterations, use form CF1R-NCB=01 to document the water heater alteration, ; Insir6c4ions for sections with column numbers are Qiven below: 1. Water Heating System Identification or Name: enter a unique name for the Water Heating System.. 2. Water heating system type: Domestic Hot Water.IDHW),' Hydronic, Combined Hydronic, •or Central. DHW lifer domestic hot water, hydronic isaw . ater heating system used for space heating only; combined hydronic are when the water heater will provide both space conditioning and .domestic hot water. 3. Water heater type: For non -central systems only Small Storage or Small Instantaneous are allowed. For Central systems pick from large Storage, Small Storage, Heat Pump, Boiler, Large Instantaneous, Small Instantaneous or Indirect. 0 CERTIFICATE OF COMPLIANCE CRR -ALT -014 WATER HEATER• Prescriptive Residential Alterations for Water Heater (Page 2 of 2) 4. Number of water heaters in system: In single-family and multi -family with water heaters in each dwelift units the value Is 1. For multi -family centraf systems serving multiple dwelling units enter the total number of water heaters. 5. Water'heatee volume (gal): tank capacity In gallons..For individual water heaters for a dwelling unit this will be 60' gallons or less. 16 instantaneous, enter n/a. For multi -family central systems enter the total storage volume; 6. Fuel Type: Gas, Propane, Electric (Only If natural gas is not available) ' 7. Rated Input Type: Enter the equipment input rating type, for gas or propane fired units are Btuh, for electric'fired system the un:"its arekW. . '8. Rated input Value: Enter the numeric value of rated input. 4. -Heating, Efficiency TyperEnergy Factor, AFUE, or Thermal Efficiency. From product literature "or a California Energy Commissfon di rectory.. . 10. Heating Efficiency Value: Enter the value from product literature or a'.California Energy Commission directory 11. Standby Loss (percent): Applies only to large"storage water heaters, Enter n/a for, small storage or Instantaneous water heaters. 12. Exterior Insulation R -Value: Enter the R -value if exterior. Insulation on the storage tank is installed 13. Back-up sellar savirig9 fraction: If compliance requires a back-up solar system, Indicate the solar contribution (e.g., 0.30).. External calculations are.required. 14: Central DHW Distribution System: For multi -family buildings with using a central distribution system a demand recirculation system'with at least two distribution loops must be installed. This requirement applies to any building with eight or more units. If the system is non -centra( or project is Individual units enter n/:a. 1'5. [iJuelling Unit•DHW Distribution Type: For a Central DHW.this field shall hr Stendafd: If noncentral then-pick'•froin StandaM, Demand Recirculation.—'Manu�I nr• Control, Deiiland Recirculation— Serisof Control: )f noncentral electric waterheater this must be Standard, no recirculation system shall be installed.'' DOCUMENTATION AUTHOR'S DECLARATiON STATEMENT • I certify that this Certificate of Compliance documentation is accurate and complete. .. Name: • .: �"' 'gClwner thorizedagent oContractor �P�Je;Y1 tJC�Y�l6:iZ(' Signature;.,C� d. J Company :. A1r�S wvn i" a� 3 r i Contractor license 9. $274 Za Address: %3 1>;r.o.1. 131D 1� Phone: '7roo- 60t- zfofo3. City/State/Zipi` :b.�tv� �GSe� CA W�211 Dater For assistance Or questions:regafdingthe Energy, Standards, contact the Energy. Hotline at.1-800-772-3300,! •• NavieN NPE Series Tankless Water Heaters Premium Condensing Specification Sheet Tonkless Gas Water Heater • Certified design according to ANSI Z21.10.3/CSA 4.3-2013 standards for both indoor or outdoor installations (with optional Outdoor Vent Kit) • Compatible with 1/2" gas pipe up to a length of 24 ft' ('see Installation Manual for additional information) , • Compatible with 2" PVC vent up to 60 ft" and 150 ft** using 3" PVC vent (**with no elbows) • Gas Input Ranges NPE-150 - 120,000 to 18,000 BTUh NPE-180 -150,000 to 15,000 BTUh NPE-210 - 180,000 to 19,900 BTUh NPE-240 -199,900 to 19,900 BTUh • Hot Water Flow Rate Capacity (*based on 357temperature rise) NPE-150 - 6.8 GPM NPE-180 - 8.4 GPM NPE-210 - 10.1 GPM NPE-240 - 11.2 GPM • Dual Primary and Secondary Stainless Steel Heat Exchangers for optimum efficiency and durability • Built-in Control Panel - allows adjustment of temperature settings and displays the operating status and error codes • GMMOgnFloml"Technology - "A" models come included with built-in 0.5 gallon Buffer Tank and Recirculation Pump to provide maximum comfort • INTELLIGENT Preheating - recognizes hot water usage patterns to intelligently provide hot water when needed (optional for"S models) • Temperature Options - available temperature settings for Residential applications range from 987 up to 140°F with high temperature Commercial mode capable of up to 182•F • Ready -Link Multi -System - up to 16 units can be cascaded together for increased hot water production • Reduced pressure loss for maximum hot water output • Ease of Maintenance and Service - allows for quick removal and simple repairs to waterway components such as the pump, water adjustment valve, and 2 -way valve • Freeze Protection - maintains normal operation during freezing ambient temperatures down to -5•F (standard on all models) • Uniform Energy Factor Ratings for NG and LP units NPE-18OA/21OA/240A - 0.96 UEF (0.97 EF for Canada) NPE-1505 - 0.96 UEF (0.97 EF for Canada) NPE-1805/210S/240S - 0.97 UEF (0.99 EF for Canada) • Compatible with Natural Gas (NG) and Propane (LPG)•" (... requires installation of included Field Conversion Kit by a qualified gas servicer) • Approved for Installations on Mobile/Manufactured Homes • Certified by CSA, NSF 5, AHRI, AB1953 CA Low Lead, SCAQMD (Rule 1146.2 Type 1 - Complies with 14 ng/J or 20 ppm NOx @ 3% 02) • 15 -Year Heat Exchanger and 5 -Year Parts Warranty (Residential) 8 -Year Heat Exchanger and 3 -Year Parts Warranty (Commercial).... (•••• see Navien Limited Warranty) • Optional accessories are available (see below) Sleek Design -Compatible with 2"PVC Vent and 1/2" Gas Pipe Diagnostics Up Information -- fl Down Reset Power ON/OFF Built -In Control Panel with Diagnostics Indoor and Outdoor Intake cap d% Venting Options Coupling - 2' pipe = . i, I. Non -Direct Vent (Indoor) Outdoor Vent Cap-- h Non -Direct Vent (Outdoor) AS, F EJ412 , o Job Name: Location: Engineer. Wholesaler. Contractor: Model No.: Submitted to: Remote Controller Plumb Easy Valve Set (3/4") Condensate Neutralizer Ready -Link 3' Vent Termination Caps NR-20DU.(GXXXOD1322-Single Unit) Outdoor Vent Kit External Pump Wire (30009323A -.Lead Free) Communication Cable � - .and Wall flanges (300D9757A), . (30012581A -for Pipe Cover) (GXXX001 324 - Up to 6Units) (GXXX000546) (30010604A) (GXXX001319) (GXXX3873B) (GXXX001325 - Up to 16 Units) maviem Premium Condensing Tankless Gas Water Heater Dimensions NPE Series Tankless Water Heaters Specification Sheet Specifications 'Item NPE-1505 NPE-180A I NPE-1805 NPE-210A I NPE-2105 NPE-240A I NPE-240S Heat Natural Gas 18,000- 15,000-150,000 BTU/H 19,900.180,000 BTU/H 19,900-199,900 BTU/H Capacity 120,000 Exhaust (Input) Propane Gas BTU/H 15,000-150,000 BTU/H 19,900-180,000 BTU/H 19,900-199,900 BTU/H Efficiency UEF«orNG& P) 0.96 0.96 10.97 0.96 0.97 0.96 0.97 Ratings EF (Canada) Iron NG a LP) 0.97 0.97 10.99 0.97 0.99 0.97 0.99 35"F(19"C)Temp Rise 6.8 GPM 8.4 GPM (32 Um) (26 Um) 10.1 GPM (38 Um) 11.2 GPM (42 Um) Flow Rate (DHW) 45"F(25"Temp Rise Q 5.3 GPM 6.5 GPM (25 Um) (20 Um) 7.8 GPM (30 Um) 8.7 GPM (33 Um) 67"F(36"C) Temp Rise 3.2 GPM 4.3 GPM 4.2 GPM 5.0 GPM 5.2 GPM 5.6 GPM 5.7 GPM 0 2 Um) (16 Um) (16 Um) 0 9 Um) (20 Um) (21 Um) (22 Um) Dimensions 173"(W) x 27.4"(H) x 13.2"(D) Weight 55 lbs 75 lbs 67 lbs 82 lbs 75 lbs 82 lbs 75 lbs (25kg) (34kg) (30kg) (37 kg) (34kg) (37 kg) (34kg) Installation Type Indoor or Outdoor Wall -Hung Venting Type Forced Draft Direct Vent Ignition Electronic Ignition Water Pressure 15-150 PSI Natural Gas Supply Pressure 3.5 in WC -10.5 in WC (from source) Propane Gas Supply Pressure (from source) gin WC-13in WC Natural Gas Manifold Pressure -0.04 in WC- (min -max) -038 in WC -0.04 in WC --0.84 in WC -0.05 in WC --0.36 in WC -0.05 in WC--0.58.in WC Propane Gas Manifold Pressure -0.04 in WC (min -max) -0.42 in WC -0.05 in WC --0.50 in WC -0.10 in WC --0.66 in WC -0.10 in WC --0.78 in WC Minimum Flow Rate 0 GPM (0 Um) for"A" models / 0.5 GPM (1.9 Um) for"S" models Cold Water Inlet 3/4 in NPT Connection Saes ' Hot Water Outlet 3/4 in NPT Gas Inlet 3/4 in NPT Power Main Supply 120V AC, 60Hz Maximum Power Supply Consumption 20OW (max 2A), 350W (max 4A) with external pump connected Casing Cold Rolled Carbon Steel Materials Heat Exchangers Primary Heat Exchanger: Stainless Steel Secondary Heat Exchanger: Stainless Steel Exhaust 2" or 3" PVC, CPVC, Polypropylene 2" or 3" Special Gas Vent Type BH (Class II, A/B/C) Venting Intake 2" or 3" PVC, CPVC, Polypropylene 2" or 3" Special Gas VentType BH (Class II, A/B/C) Vent Clearances 0" to combustibles Safety Flame Rod, APS, Ignition Operation Detector, Water Temperature High Limit Switch, Exhaust Temperature High Limit Sensor, Devices Power Surge Fuse Gas-fired, tankless, condensing, wall -mounted water heater(s) shall be direct vent NPE Series models as manufactured by Navien, Inc. and are certified by CSA Group to the latest edition ofANSI standard Z21.10.3/CSA 4.3. Water heoter(s) shall have a 15 year limited Heat Exchanger warranty and 5 -year limited Parts warranty (8 year Heat Exchanger and 3 -year Parts for Commercial use) per Navien Limited Warranty. Unit(s) shall be designed to burn natural gas and can be for use with propane when a Field Conversion Kit is installed. Water heater(s) shall have a nominal flow rate capacity of GPM/GPH at °F rise with rated input of BTU/hr. Water heater(s) shall be vented with 2" PVC/CPVC vent pipe at a distance not to exceed 60'.(or equivalent) with each elbow equal to 8' of pipe length ora"PVC/CPVC vent pipe at a distance of 150' (or equivalent) with each elbow equal to 5' of pipe length. Water heater(s) is rated for 150 PSI working water pressure and 300 PSI test pressure. Gas supply pressure shall be 3.5" to 10.5" WC for natural gas and 8.0" to 13.0"WC for propane. Unit(s) shall have a steel case, dual stainless steel heat exchangers, eco premixed burner, negative pressure gas valve, dual venturi, 3/4" inletgas connection, 3/4" brass inlet/outlet water connections, water holding capacity of 0.6 gallons for the NPE-1505, 1.0 gallon for the NPE-180A model (0. 7gallonsfor NPE-180S model), 1.2 gallons for the NPE-21 OA/NPE-240A models (0.7 and 0.9 gallons for NPE-2105 and NPE-240S models respectively), and a condensate collector. The NPE-1 SOS model weighs 55 lbs, the NPE-180A model weighs 75 lbs (NPE-1805 weighs 67 lbs), and the NPE-210A/NPE-240A models weigh 82 lbs (NPE-2105 and NPE-240S weigh 75 lbs). Unit(s) shall include featuressuch as an adjustment for installations at high elevation, temperature lockout, and temperature options from 98-1207 in 1 Y intervals and 125-140°F in 5°F intervals. The unit(s) shall include additional temperature options of 150-180°F in 10°F intervals, and 182°Ffor high temperature commercial applications. All NPE "A" models shall include an internal circulation pump and 0.5gallon buffer tank. The water heater(s) shall be controlled by an internal circuit board that monitors the inlet and outlet temperatures with installed thermistors, sensing and.controlling flow rate to set point temperature with air fuel ratio controls in order to maintain thermal combustion efficiency. Unit(s) shall include safetyfeatures such os flame sensor system, high limit sensors, overheat prevention device, freeze protection mode, and fon motor rotation detector. Multi -system (cascade) applications that require 2 to 16 units shall be installed by connecting the units using cable -only connections'(Reody-Link). The water heater(s) exceeds the energy efficiency requirements ofASHRAE 90.1-2013 and is listed by SCAQMD rule 1146.2 (Type 1) for Low NOx that complies with 14 ng/) or 20 ppm NOx requirements @ 3% 02. *Navien reserves the right to change specifications at any time without prior notice Navien, Inc. 20 Goodyear, Irvine, CA 92618 Ph: (949)420-0420 Fax: (949)420-0430 www.Navien.com Rev. 6/15