Loading...
BRES2015-038778-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 Application Number: Property Address: APN: Application Description Property Zoning: Application Valuation: Applicant: SUNROSE CORPORATION 72-850 SOMERA ROAD PALM DESERT, CA 92260 T4+r4lwQ" COMMUNITY DEVELOPMENT DEPARTMENT BUILDING PERMIT BRES2015-0387 53459 VIA DONA 777420025 TURBAN / HIDEAWAY / SINGLE FAMILY DWELLING $465,835.60 LICENSED CONTRACTOR'S DECLARATION . I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, and my License is in full force and effect. License Class: B License No.: 533670 Date: a �Co ractoI OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: (1 I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through hisbr her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). () I, as owner of the property, am exclusively contracting with licensed contractors to construct the project.. (Sec.'7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). ( ) I am exempt under Sec. . B.&P.C. for this reason Date: Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Lender's Owner: SCOTT TU R 2363 PEBB' NORTHFIEI 04 Contractor: SUNROSE CORPORATION 72-850 SOMERA ROAD PALM DESERT, CA 92260 (760)773-6633 Llc. No.: 533670 . WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: I have and will maintain a certificate of consent to self -insure for workers' .compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier: _ Policy Number: _ I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, if I should become subject to the workers' compensation provisions of Section 3700 of the Labor Code, I shall forthwith comply with those provisions. WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO.THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT' IMPORTANT: Application is hereby made to the Building Official for a permit subject to the conditions andrestrictions set forth on this application. 1. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application , the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents, and employees for any act or omission related to the work being performed under or following issuance of this permit. 2.. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is correct. .I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter upon the. above-mentioned property for inspection purposes!1 Data% O /5 1 / Signature-(Applican i FINANCIAL INFORMATION DESCRIPTION ; ACCOUNT" QTY 'AMOUNT. PAID PAID DATE ART IN PUBLIC PLACES - RESIDENTIAL 270-0000-43201 0 $664.59 $664.59 12/28/15 PAID BY METHOD RECEIPT # CHECK # CLTD BY SUNROSE CORPORATION CHECK R11789 17578 MFA Total Paid for ART IN PUBLIC PLACES - AIPP: $664.59 $664.59 DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE. BSAS SB1473 FEE 101-0000-20306 0 $19.00 $19.00 12/28/15 PAID BY METHOD • RECEIPT # CHECK # CLTD BY SUNROSE CORPORATION CHECK R11789 17578 MFA Total Paid for BUILDING STANDARDS ADMINISTRATION BSA: $19.00 $19.00 DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE -DIF - CIVIC CENTER 252-0000-43200 0 $942.00 $942.00 12/28/15 PAID BY METHOD RECEIPT # CHECK # CLTD BY SUNROSE CORPORATION CHECK R11789 17578 MFA DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE DIF - COMMUNITY CENTERS 254-0000-43200 0 $129.00 $129.00 12/28/15 PAID BY METHOD RECEIPT # CHECK # CLTD BY SUNROSE CORPORATION CHECK R11789 17578 MFA DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE DIF - FIRE PROTECTION 257-0000-43200 0 $433.00 $433.00 12/28/15 PAID BY METHOD RECEIPT # CHECK # CLTD BY SUNROSE CORPORATION CHECK R11789 17578 MFA DESCRIPTION', ACCOUNT QTY AMOUNT PAID PAID DATE DIF - LIBRARIES 253-0000-43200 0 $344.00 $344.00 12/28/15 PAID BY METHOD RECEIPT # CHECK # CLTD BY SUNROSE CORPORATION CHECK R11789 17578 MFA DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE DIF - PARK MAINTENANCE 256-0000-43200 0 $40.00 $40.00 12/28/15 PAID BY METHOD RECEIPT # CHECK # CLTD BY SUNROSE CORPORATION CHECK R11789 17578 MFA DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE DIF - PARKS/REC 251-0000-43200 0 $2,048.00 $2,048.00 12/28/15 PAID BY METHOD RECEIPT # CHECK # CLTD BY SUNROSE CORPORATION CHECK R11789 17578 MFA DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE DIF - STREET MAINTENANCE 255-0000-43200 0 $116.00 $116.00 12/28/15 PAID BY METHOD RECEIPT # CHECK # CLTD BY SUNROSE CORPORATION CHECK R11789 17578 MFA DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE DIF - TRANSPORTATION 250-0000-43200 0 $2,842.00 $2,842.00 12/28/15 . . . ......... .. W-11-11 V, M Zi, ViiMilfiM �Eg PW, <RWBow �NQIARECEIPT A4 :, 5 _84 #1 SUNROSEXIORPORATION CHECK' 'R1178191, 1.7578 MFA -Total Paid for DIF -,SINGLE, FAMILY DWELLING: $6;64.00 $6,894.00,1 -'DESCRIPTIONS a ?f4 NT&0 gy 1`0 �40AIWIJATF3 TEMP POWER SERVICE 101-0000-42403 0 24.17 $24.17 12/28/15 D E 14. CHECK?,ffi, CLTD Byffi.. SUNROSE CORPORATION CHECK R11789 17578.."l' MFA Nr ON"k' Et � fl� g;gg 46� MAR OUNT i FRIMMAI PAID DATE 50 g mw,, i, 1A 44� i-9100 TEMP POWER SERVICE PC 10170000-42600 0. $16:02 $16.92 12/29/15 y'x mnm ,r, '§PA Z, � q. ___ �m 4%. "M � , HOD, 01 W, 4-,ve, q _m ANS, I �0-110. NKN _Q SUNROSE CORPORATION CHECK R11789 .,17578 MFA Total Paid for ELECTRICAL: $41.09,: $41.09. 4f gj_ T. A C JdbAf rANI),I)ESCRI IRS, .21 RESIDENTIAL, EA ADDITION 1,000SF 101-000042463 0 $73.98 $73.98 12/28/15 PAIDiBY,;,gM'n, 301. 5-w! "I'ME D, wll�;p Lgjg �'t ECK _NM,,1% t w I- �r4 v: w�", .RECEIP OR SUNROSE CORPORATION CHECK R11789 17S78. -MFA DESCRIPTIONyF"REV, x NT a 'PAID- ME RESIDENTIAL; EA ADDITION 1,000SF,.PC. iol-0000-42600 . $30.4 8 $30.48 12/28/15- jk­ X W A yp 1% IP m PLA IR �7 NNEW 115 SUNROSE CORPORATION .CHECK R111899 9 -17578 FA % 5 t, 66NT "Am "AMOUNT w 01, f0AWME "4- RESIDENTIAL, FIRST 1,000SF 101-�000042403 1 0 . .$145.03 $145..03 12/28/15, M, M, '0 N �­ It mxmumsm I M9140 DNA'M CHECK SUNROSE CORPORATION' . 'CHECK R 1 117 . 89 17578 MFA g, 90Z IMOUNT�� ­PAIMDATE-4- 4. IMINIMOT RESIDENTIAL; FIRST1,000SF,,PC 101-0000-42600' 0 $47.86 $47.86 12/28/15 gy %-N ETH WIN CID 10 SUNROSE CORPORATION CHECK, R11789 17578 MFA, Tota.1 Paid-f6rll�E&RICAL NEW CONSTRUCTION: $297.35 $297,35 -F �71­,11�1�mx --v-, m, - xg!, p. -FDESCRIPTION',�! EMU RISEN T Y 9Q. ME PAID �k RESIDENTIAL PRECISEGRADING -CUSTOM 101-0000-42408 $36,.26 $3616 12/28/15 HOME LOT >7KSF E7PAl f112 b ma W.I., x1Rnvgwx'RZ11ftZ ruli:OE -1 H09;k,`!`,K-- M ET R �, 9 killvl -pit 11 mi. 1 , ", TIM 4 V g MM'w1m, ZZ , g" 3112 SUNROSE CORPORATION CHECK' R11789 17578. MFA O,UNT AMOUNTS1,11mr `'- PAIDIR NO 'NO ANN'.- W RESIDENTIAL PRECISE GRADING CUSTOM 101-000042600 0 $181.29.- $181.29 12/28/15 HOMEIOT >7KSF'PC ", mma PAID BYM El 4,7�� R EC L I CHECK42 �C b f"T -,BY D-K, IN I :E R'NEK �NOARR!_f� 7 7 -3.1 SUNROSE CORPORATION CHECK. R11789 17578 . MFA Total Paid for GRADING: $217.55 $211.55.. DESCRIPTION gi Z=wffl�, .1V ACCQUNT QTY WONT R _'N JD�, EMMA IMDAT ,r, li$ �VR �4� P#R% f, W-6." CONDENSER/COMPRESSOR, 101=0000-42402 :0 $181.30 $18130, 12/28/15 PAID BY METHOD RECEIPT.# CHECK# CLTD BY SUNROSE CORPORATION CHECK R11789 17578 MFA DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE CONDENSER/COMPRESSOR PC 101-0000-42600 0 $120.85 $120.85 12/28/15 PAID BY METHOD RECEIPT # CHECK # ' CLTD BY SUNROSE CORPORATION CHECK R11789 17578 MFA DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE EXHAUST HOOD 101-0000-42402 0 $12.09 $12.09 12/28/15 PAID BY METHOD RECEIPT # CHECK # CLTD BY SUNROSE CORPORATION CHECK R11789 17578 MFA DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE EXHAUST HOOD PC 101-0000-42600 0 $4.83 $4.83 12/28/15 PAID BY METHOD RECEIPT # CHECK # CLTD BY SUNROSE CORPORATION CHECK R11789 17578 MFA DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE FURNACE 101-0000-42402 0 $181.30 $181.30 12/28/15 PAID BY METHOD RECEIPT # CHECK # CLTD BY SUNROSE CORPORATION CHECK R11789 17578 MFA DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE FURNACE PC 101-0000-42600 0 $120.85' $120.85 12/28/15 PAID BY METHOD RECEIPT # CHECK # CLTD BY SUNROSE CORPORATION CHECK R11789 17578 MFA DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE VENT FAN 101-0000-42402 0 $96.72 $96.72 12/28/15 PAID BY METHOD RECEIPT # CHECK # CLTD BY SUNROSE CORPORATION CHECK R11789 17578 MFA DESCRIPTION ACCOUNT QTY 'AMOUNT PAID PAID DATE VENT FAN PC 101-0000-42600 0 $38.64 $38.64 12/28/15 PAID BY METHOD RECEIPT # CHECK # CLTD BY SUNROSE CORPORATION CHECK R11789 17578 MFA DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE WALL HEATER 101-0000-42402 0 $74.13 $74.13 12/28/15 PAID BY METHOD RECEIPT # CHECK # CLTD BY SUNROSE CORPORATION CHECK R11789 17578 MFA DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE WALL HEATER PC 101-0000-42600 0 $36.27 $36.27 12/28/15 PAID BY METHOD RECEIPT # CHECK # CLTD BY SUNROSE CORPORATION CHECK R11789 17578 MFA Total Paid for MECHANICAL: $866.98 $866.98 DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE NEW CONSTRUCTION PERMIT 101-0000-42400 0 $730.53 $730.53 12/28/15 PAID BY METHOD RECEIPT # CHECK # CLTD BY SUNROSE CORPORATION CHECK R11789 k 17 7 17578 MFA' Total Paid for NEW. CONSTRUCTION PERMIT: $730.53 $730.53. Y.f �#,iE `4�5 �. i;y p.: -. ".PF `,r.l 'ns; •%+, '113's� 'c i ,� T ACCOUNT ir,Q r� s MOON T_ : PAID DADA Ea. AI T k" .DESCRIPTION€ E;ki ... .. r<. :,:.... ....... �x, u��xb .. TY c �Af zP NEW CONSTRUCTION PLAN.CHECK 101-0000-42600 0. $1,200.00 '$1,200.00 10/6/15 - y r%_ls r Y.n'.-: k. _! ✓,, r . �-a. •i 'a< PAID BY =�' � a'eav -.�R `j. -r,,& ' }� ' ���e����¢-, i� ;v'sr3�'ia'Y;,ti �i><".` -;RECEIPT #k # "�4CLTD �:'.�zh"•• BYE 3 ny' ,..`� '�i�a ,' � .'�. L��`'�v s rMETHOD i,.,-.: �<T��r4:tka�'�" ��5'��,'.*�fz� s ':�,h�k..r�§4��=.�....;.4�'� .. "1 :,:�`��'•k��� {ECK r.;,a ;::.irt.. s-�^��'� "7k,'�,..rr :.ia. v,-c� SUNROSE:CORPORATION. CHECK 119791 17371' SGU •.;' a :.;1txF x! # 7 ...'�r"rX;: .Y ? ..y.C`f� �✓'�" i x`"' DESCRIPTION ,�,�,r:• 55+'S' .�xd... Li,.��:. "si-. AMOUNT Y". ....� " a-�`t-`� R ".r+�� 7 WN � �N QTY 7 " PAID k h xPAIDpUATE NEW CONSTRUCTION PLAN CHECK ` 101-0000=42600 " 0 $355.32. ' "$355:32 12/28/"15 $ €.:, ivai "tiE '.%r n . A,.':tt' ,yX1 :. ; METHOD�,tRECEIP;T#.CHECK < �aX;.ki£5R`�<Yr^�vrl�i iy "i:�„4d �.PAID�BY�O SUNROSE CORPORATION CHECK ". ,R11789 11578"' MFA Paid foe, NEW CONSTRUCTION PLAN CHECK: $1;555.32: $1;555..12 yTotal <: MIR "4f§^'Ti., t' idhRi{ # t`:'y.'•,} i.�. DA�TEa �d�y��DESCRIPTI:-wE1000UNT"��QTY,�,��4MOUNTPAID PAID BACKFLOW DEVICE . •.., 101-0000=42401 0. ' $12.09 x.$12:09 .12/28/15 ,, l ? 'e 1° J ' •5 3 .syr Y BY a "E paF` rzw ' v METHOD i.gr _z_''SF�'+i5% � A� S '. k`ir'3�e ;xtK ?i. e'bP-�' Tm,"A RECEIPT# "_ �`rox F' yiti', JiS i d2 CHECK#�� CLTD BY ¢" PAID r ? F , 35`A:,'did''.d,W-1-1-nsan.a:if.=Ehl r"r,...at#2. ?S <u.'.' - 1.,'%�k.F.:..,,-.r,. wr"E".<4...�.'U4:..:,_..,,. -'.h '�",�..4!'.:Tdscw. ."I .t SUNROSE CORPORATION CHEC1. K ` R11789 - 17578 -MFA Y , ACCOUNT �� mu.,::^ezv" , ,r '"ew >:S.x AMOUNT r:i••"%-�«"='F-':..z`�rrr� PAIDy Xf >wGz?'S€k§s 33:!,u€E-:- xDESCRIPTION i .. 3mv: 3aiS.Y1'Si�,i Sa.'ice%"?a..6�b.. fQTY� +P , tiil.n E?9..< ;i C'YM £'yni# frPAID`DATE; BACKFLOW DEVICE PC 101-0000-426001. 0 . $4.83 $4.83 12/28/15 rJ 4 .1 ii%f 4Y ,t2 K' _! 'X ..:'.gip l" -2C '"�i ,{iP: e$tt2i"":. PAl"Yr r ,: Repj'<�.,i&n". 'VT.L ✓r 'n '.:two 4_ e '. s S :. T' -! CHECK # ?.an` CLTO BY g f .< SUNROSE CORPORATION CHECK" -1111789: 17578 MFA `'{DESCRIPTION�xAC000NT�QTY 5i•zA''k�°.4.F.ze �AMO€UNT�PAID�PAiOyDATE Ei»ti ,9 BUILDING SEWER "101-0000-42401 0 $12.09' $12.09 W28/15 xmti�. 44M METHOD..aaRECEIPT#Rgg ..a„PAIDBYa�fVv ?�CHECK#a7DuBY SUNROSE'CORPORATION CHECK :- R11789 17578 MFA _ f :r:Sa;s.s. ACCOUNT QTrU p „t,Z,�.sa.�::'_x ? °€w 'AMOUNT"q .,:DESCRIPTION ,x Y f PAID PAID OATE BUILDING.SEWER,PC 101-0000-42600. '0' $12.09 ,$12.09 12/28/15 u u, 113 Fck1� , nig � RECEIPT # � � CLTD BY WMETHOM.,, r�ulpw,«d W "< .- Nsem,"a d r���'�K�' SUNROSE CORPORATION . - CHECK `1111789 "17578 MFA l� 3 r i4r-4ai.. DESCRIPTION C<+ NT �,,, QTY : x r P-AIDxBY;a'i ���E �`ttV..E�'^�`fE'£�� 1�: `METHODa'.•: e��"�"a rd �' #�CLTDY� .;: ,4RECEIPTE# " r ' GHEGK SUNROSE CORPORATION CHECK R11789 17578 MFA 4"' `^"E't` ` � z DESCRIPTION t ^Yz, 'q�"-.ErN'Y-. _�, a,a..;'�.. 3 * "'�i4€°i' ��►T1f z'k%r�Y `7-( :'?"bye"-ve`3f. ,v2"xp t $"yy'p'' hr. ;. yl' 4 Y< ` .w.}`."F.:P.E.rSi' �PAIDtDATEi c i'7 F ,�€Sf.->7=; ,. '_... 'Z...a , . F+i x•: x z `ae..,�;•:.Z, :T'?�t>r.t.,±.':';".tEf: .ACCOUNT' . a*d.__•?a:x:..a ?AMOUNT £FAID .`"s.t°.�,,.�`S<�2.::F;!"sw°v ROOF DRAIN, ' 101-0000-42401 0" $48.36 $48.36 12/28/15 v >' X.' n>PAID361fN� sYs,::.`x??£.#`�a'M ME+T:HOD# ix"fi; .'`>.a'"*'.a,R-'r�e`'Y, *;#,:'�` #��'Ck1ECK P >k.: +s''y`g ""Jar:''?�e: r'e # Ey" ':zi.'Y.".:!$''..-: •*', 4 .'A t-f.�"n4n. �.:.pY.4€ 2.'Yi't,�. _ts.--.'7 ,-.i.'+M.X✓�,��`:-,5t�, �S':.. '1!`$�l9'ti; ^.xY`K,`f,."-.: i�RECEIPyT ..r3iSa,l�f.{. E��;,'t•�f. ��CLvTD(BY .;:r "..7: 3i 7. Y. '.:;M,..<c.e�Lf, �c< S�'�. iE-';b{�:'•7P :r'�3i SUNROSE CORPORATION CHECK R11789 17578 MFA '„i, ay9i ...qit;,”" w DESCRIPTION r `:...'-,&.a; `: AMOUNT � MAO" PAID �>>x�E PAIVDATE k f�..y ACCOUNT „QTY ._x ROOF DRAIN PC 101-0000-42600 0 $48.36 $48.36 12/28/15, �i'1.4:> PAID;BYa'` u1111ETHOD RECEIPT°4# h CFIECK#_ , ,nx;.xkt,.. -. iY: tS`:<z::-xos4;: en A, --:a": °Yk:r•:$;x `e%.S4?�v :z< s"'3 . '',•." `u;:.'s".: f .A ,."!`v»s-F <;: r;.: ;;k���;:s�F.Y;N s,i .CLTDBY`. SUNROSE CORPORATION CHECK :R11789 17578 MFA rlia<y 4 ..'.-':;X,i -;yz .r a .k' '" ;;DESCRIPTION;, `, �:' �,".,, 4 gif` "i`a, § ,. $ C'$ hY;°:r �'2 °x t ' ACCOUNT?ffAMOUNT�z` _' ` .. ,`'#Eij•43£ bids; PRIDE DATE? rr�"�H_„h. s��--c,. , fF..,: � � :5"'z: z.��C�'. a�<::,.W:..:...:a`� `:�arFu tPAID kap-',::'fit.X51AE�s WATER HEATER/VENT 101-0000-42401 0 $24.18• $24.18 12/28/15 ras ..x.�•<b,15 METHODz�°. +r3X.,A3:.'zi'.:i L''!{'{Y tii # CL*Tm4aD BsE rPAIDoBY s� ,..�` <''x,�RECEIPT#r s„CHEW�mmCK ' SUNROSE CORPORATION CHECK R11789 ` 17578 MFA ' �E yK y _. ,t ?. ..>:q.: *✓, ir.x, DESCRIIONm1dibfix„_i w `r*AN;[Ck`:vCiO�s+`'U'i*RNiXiT�W"1F Ff y ADf r».._ �PT;' R DYPAI).g � ATENINE; ., F< WATER HEATER/VENT PC. !. .101=0000-42.600. 0 $14.50 $14.50 ' .12/28/15 3l•;'. E Y r f M . 'h ay. F.! BY � ' K '�`:. I wEi METH�� : _MA iln iy i RECEIPT #�"� ig`ua If,,�. CHECK s .PAID: -? ... 4t.:_ t. * '>:..:a_ e-, <. -;" •wa.,. ;� ... _.:.... �- "; _ .. mss ".-.rkFax.-. f�.- ��`s�r,_...: SUNROSE CORPORATION CHECK. -1111789 17578 MFA DESCRIPTION }< PAID x�s iPAIDfDATEz , �ACCOUNTu�n.ffl £` i /AMOUNT r -., Y 4 '6 WATER SYSTEM INST/ALIT/REP 101=0000-42401',' 0.. $12.09 $12.09. 12/28/15 4• ,y BYh e'Effii E,.. q3 i'rte METHOD Y'@y�._.r.'M 1a ! CHECK # 4$ 4 xc CLTD BY ,PAID fi e. � ., -.-- �s & NRECEIP,T�# �.�.dr.�«..� r.. SUNROSE CORPORATION CHECK; R11789 17578 MFA va .w� �ir � r:. ?� s..v § `:���.4:^ $. sa .: E..''�QM°T°?�✓#Y. yr�.Li?�"'' AESCR .�':`�''�" ;,*; fS =� n� >.;: n�.. ,r . ,.rlDr--v.>. d, • _._,x-a.a.e.�€.. _14'._.k'r ::�'^ 4.Fa'r��..£.�( _.kAC..".C�iY:OfU§X-`a^.=N�,+T-bV..xi'�?'.lift ' As`. `.,..A.1ii�i4MR.5.,ik�`�LOa'iSYUS% h•NzoK'b,^A.#TxS{z`� .sk4�3�Pil,^mD d� 3� WATER.SYSTEM INST/ALT/RERPC "101=0000-42600 0 $12:09 $12.09 '-12/28/15' -: _ ° x`Y.' E' tia_. PAID ,BY '-v - _x.. +tid:. r+a,_ a h, si'' ' +` tiFi '-' METHOD<RECEIPT# .c s; q.� sk' Cz;t4>, .{ti � ,x � ., . ,:..a, a !3:�°3^'v,44 '...:.'� CHECK #' BYr ti� 4a f v., •Y ,.;. .., n ... ,^n :.a a �� ,� sW— 'rd a{CLTO SUNROSE CORPORATION CHECK., ` 'R13789�' 17578 MFA Total.Paid for'.PLUMBING FEES: $9x38.15 -$918 .15 - _ 4 vCE:: , C ..'v.::iY'LFW :: iY F 'FE:w: #.��"% fro DESCRIP�TION�� -n� t' -•'r. L§ < l E 5^ls't'l4�YthTzo-[L':. ;y .fiT 1 Si KN rt!� _ PAID"'PAIDDAE; q t+ , : :� A000UNT� yQTYAMOUNTa� f' SMI - RESIDENTIAL' 101-0000-20308" 0 $60:56 $60.56 12/28/15 by _.; (.y{.i t'W i �” 1:; 6. ti',sp✓ WS'�;y }.. d• PAIDcBYtE C a!, Si .. "°C S'STE+>i�xsa 3 x`�k $'a°a v "yf �MMINI RECEIPT# H'.tn CHECK #�* `�eaxei 3�CLTD BY h*��.��"StMETHOD, .v �`^,..iYmkT`. wn:&', r lw.'�4�:.""x+E. SUNROSE CORPORATION '.. CHECK' 1111789 17578 MFA Total Paid for STRONG MOTION INSTRUMENTATION $60:56.'. $60.56 A; 5• % F"F. 3`m DESCRIPTION aq*%`,x i'.�. '°. y ;,;kb':13d-.w' i ,� '<si' ,. A6COUNT.�QTkY..IkE fid. F ”. yi�R 4.'a"fN` ,` ; y, ^: IM AMOyUNT�tPAID @xy.;.x S'i.�i �Y%'<'bu,.3-:'dl: PAID DATE y,,r ^kFnz s SINGLE FAMILY DETACHED 224=0000-20320. 0 $1,837:44 . • ..,$1,937.44 ' 12/28/15 i 'i. i. .'J4I P -`"(. Y �s PAID,BY y>v YS,'._'q. _` w:..,,.f ..t,Ss`'''.-s•.?§.: L ..e` -'P Z .F ,` in METFiOD R a' -fib Sx ?`"ice, 'r°,F,'w*2..,r>.in ?'a' . u ;�* k e+-y'1c bs : Y ry 4 's�; �.. ��rRECEIPT�k#a�CHECK # 41 CLTD BYE e SUNROSE CORPORATION CHECK R11789' 17578 MFA Total Paid for TUMF -RESIDENTIAL: $1,837.44: $1,837.44 • Description: TURBAN / HIDEAWAY / SINGLE FAMILY DWELLING Type: BUILDING, RESIDENTIAL Subtype: DWELLING - SINGLE Status: ISSUED Applied: 10/6/2015 SGU FAMILY DETACHED Approved: 12/21/2015 J10 Parcel No: 777420025 Site Address: 53459 VIA.DONA LA QUINTA,CA 92253 Subdivision: TR 29894-4 Block: Lot: 42 Issued: 12/28/2015 MFA Lot Sq Ft: 0 Building Sq Ft: 0 Zoning: Finaled: Valuation: $465,835.60 Occupancy Type: Construction Type: Expired: 6/25/2016 MFA No. Buildings: 0 No. Stories: 0 No. Unites: 0 12/9/2015 Details: NEW 5095 SQ. FT. SFD THIS PERMIT DOES NOT INCLUDE POOL, SPA, BLOCK WALLS, DRIVEWAY APPROACH, FIRE PIT, BBQ, AND WATER FEATURE. HOME IS FIRE SPRINKLED PER 2013 CRC CODES. 76 7 „j Applied to Approved IM Approved to Issued CHRONOLOGY.TYPE STAFF NAME ACTION DATE COMPLETION DATE NOTES NOTE JIM JOHNSON 10/20/2015 10/30/2015 NOTE JIM JOHNSON 12/4/2015 12/9/2015 NOTE JIM JOHNSON 12/23/2015 12/21/2015 NOTE STEPHANIE GUMPERT 12/22/2015 12/22/2015 JENNY BROUGHT IN SCHOOL FEE RECEIPT. SEE ATTACHMENTS. PLAN CHECK COMMENTS FROM CONSULTANT KAY HENSEL 10/30/2015 10/30/2015 STRUC RFC 10829/2015 RECEIVED PLAN CHECK COMMENTS FROM CONSULTANT KAY HENSEL 12/18/2015 12/18/2015 STRUC APPROVABLE -12/18/2015 RECEIVED PLAN CHECK PICKED UP STEPHANIE KHATAMI 12/9/2015 12/9/2015 JENNY Printed: Monday, December 28, 2015 11:32:43 AM 1 of 8 C� SYSTEMS PLAN CHECK SENT TO KAY HENSEL 10/6/2015 10/6/2015 SENT TO YOUNG 10-06-15 OUTSIDE PC PLAN CHECK SENT TO KAY HENSEL 12/16/2015 12/16/2015 STRUC TO YOUNG FOR ASAP P/C. OUTSIDE PC PLAN CHECK SENT TO STEPHANIE. GUMPERT 11/23/2015 11/23/2015 OUTSIDE PC - PLAN CHECK SUBMITTAL STEPHANIE GUMPERT 11/23/2015 11/23/2015 RECEIVED PLAN CHECK SUBMITTAL STEPHANIE GUMPERT 12/15/2015 12/15/2015 RECEIVED PLAN CHECK SUBMITTAL STEPHANIE KHATAMI 10/6/2015 10/6/2015 RECEIVED TELEPHONE CALL JIM JOHNSON 10/30/2015. 10/30/2015 CALLED JENNY McINTYIER TO INFORM HER THE PLANS ARE . READY FOR CORRRECTIONS TELEPHONE CALL JIM JOHNSON 12/9/2015 12/9/2015 CALLED JENNY McINTIER TO INFORM HER PLANS ARE READY FOR CORRECTIONS CONDITIONS CONDITION DATE DATE DATE. CONTACTSTATUS REMARKS NOTES. TYPE ADDED.`REQUIRED : ' SATISFIED . READY TO ISSUE JIM JOHNSON 10/30/2015 PENDING GRADING PLAN NOT SIGNED CHECKLIST CONTACTS NAME TYPE NAME ADDRESSI CITY STATE ZIP,:: PHONE FAX ... EMAIL APPLICANT SUNROSE CORPORATION 72-850 SOMERA ROAD PALM DESERT CA 92260 CONTRACTOR SUNROSE CORPORATION 72-850 SOMERA ROAD PALM DESERT CA 92260 OWNER SCOTT TURBAN 2363 PEBBLEFORK LN I NORTHFIET__L IL 0 FINANCIAL INFORMATION Printed: Monday, December 28, 2015 11:32:43 AM 2 of 8 chviAl MY SYSTEMS Permit Details PERMIT NUMBER City of La Quinta BRES2015-0387 Printed: Monday, December 28, 2015 11:32:43 AM 3 of 8 CC7fV sysrcMs CLTD DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE RECEIPT # CHECK # METHOD PAID BY BY ART IN PUBLIC PLACES - 270-0000-43201 0 $664.59 $664.59 12/28/15 R11789 17578 CHECK SUNROSE MFA RESIDENTIAL CORPORATION Total Paid for ART IN PUBLIC'PLACES - AIPP: $664.59 $664.59 BSAS SB1473 FEE 101-0000-20306 0 $19.00 $19.00 12/28/15 R11789 17578 CHECK SUNROSE MFA CORPORATION Total Paid for BUILDING STANDARDS ADMINISTRATION $19.00 $19.00 BSA: DIF - CIVIC CENTER 252-0000-43200 0 $942.00 $942.00 12/28/15 R11789 17578 CHECK SUNROSE MFA CORPORATION DIF - COMMUNITY 254-0000-43200 0 $129.00 $129.00 12/28/15 R11789 17578 CHECK SUNROSE MFA CENTERS CORPORATION DIF - FIRE PROTECTION 257-0000-43200 0 $433.00 $433.00 12/28/15 R11789 17578 CHECK SUNROSE MFA CORPORATION DIF - LIBRARIES 253-0000-43200 0 $344.00 $344.00 12/28/15 R11789 17578 CHECK SUNROSE MFA CORPORATION DIF - PARK 256-0000-43200 0 $40.00 $40.00 12/28/15 R11789 17578 CHECK SUNROSE MFA MAINTENANCE CORPORATION DIF - PARKS/REC 251-0000-43200 0 $2,048.00 $2,048.00 12/28/15 R11789 - 17578 CHECK SUNROSE MFA CORPORATION DIF - STREET 255-0000-43200 0' $116.00 $116.00 12/28/15 R11789 17.578 CHECK SUNROSE MFA MAINTENANCE CORPORATION DIF - TRANSPORTATION 250-0000-43200 0 $2,842.00 $2,842.00 12/28/15 R11789. 17578 CHECK SUNROSE MFA CORPORATION Total Paid for DIF - SINGLE FAMILY DWELLING: $6,894.00 $6,894.00 TEMP POWER SERVICE 101-0000-42403 0 $24.17 $24.17 12/28/15 R11789 17578 CHECK SUNROSE MFA CORPORATION TEMP POWER SERVICE 101-0000-42600 0 $16.92 $16.92 12/28/15 R11789 17578 CHECK SUNROSE MFA PC CORPORATION Total Paid for ELECTRICAL: $41.09 $41.09 Printed: Monday, December 28, 2015 11:32:43 AM 3 of 8 CC7fV sysrcMs u 6`M0F'n;F�' Printed: Monday, December 28, 2015 11:32:43 AM 4 of 8 CA? SYSTEMS CLTD DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE RECEIPT # CHECK # METHOD PAID BY BY RESIDENTIAL, EA 101-0000-42403 0 $73.98 $73.98 12/28/15 R11789 17578 CHECK SUNROSE MFA ADDITION 1,000SF CORPORATION RESIDENTIAL, EA 101-0000-42600 0 $30.48 $30.48 12/28/15 R11789 17578 CHECK SUNROSE MFA ADDITION 1,000SF, PC CORPORATION RESIDENTIAL, FIRST 101-0000-42403 0 '$145.03 $145.03 12/28/15 R11789 17578 CHECK SUNROSE MFA 1,000SF CORPORATION RESIDENTIAL, FIRST 101-0000-42600 0 $47.86 $47.86. 12/28/15 R11789 17578 CHECK SUNROSE MFA 1,000SF, PC CORPORATION Total Paid for ELECTRICAL - NEW CONSTRUCTION:. $297.35 $297.35 RESIDENTIAL PRECISE GRADING - CUSTOM 101-0000-42408 0 $36.26 $36.26 12/28/15 R11789 17578 CHECK SUNROSE MFA CORPORATION HOME LOT >7KSF . RESIDENTIAL PRECISE GRADING - CUSTOM 101-0000-42600 0 $181.29 $181.29 12/28/15 R11789 17578 CHECK SUNROSE MFA .CORPORATION HOME LOT >7KSF PC Total Paid for GRADING: $217.55 $217.55 CONDENSER/COMPRESSUNROSE '17578 101-0000-42402 0 $181.30 $181.30 12/28/15 R11789 CHECK MFA SOR CORPORATION CONDENSER/COMPRES 101-0000-42600 0' $120.85 $120.85 12/28/15 R11789 17578 CHECK- SUNROSE MFA SOR PC CORPORATION EXHAUST HOOD 101-0000-42402 0 $12.09 $12.09 12/28/15 R11789 17578 CHECK SUNROSE MFA CORPORATION EXHAUST HOOD PC 101-0000-42600 0 $4.83 $4.83 12/28/15 R11789 17578 CHECK SUNROSE MFA CORPORATION FURNACE 101-0000-42402 0 $181.30 $181.30 12/28/15 R11789 17578 CHECK SUNROSE MFA CORPORATION FURNACE PC 101-0000-42600 0 $120.85 $120.85 12/28/15 R11789 17578 CHECK SUNROSE MFA CORPORATION VENT FAN ' 101-0000-42402 0 $96.72 $96.72 12/28/15 R11789 17578 CHECK SUNROSE MFA CORPORATION Printed: Monday, December 28, 2015 11:32:43 AM 4 of 8 CA? SYSTEMS Permit Details PERMIT NUMBER r - City of La Quinta BRES20115=0387 Printed: Monday, December 28, 2015 11:32:43 AM 5 of 8 CR SYST(H1S CLTD DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE RECEIPT # CHECK.# METHOD PAID BY • BY VENT FAN PC 101-0000-42600 0 $38.64 $38.64 12/28/15 R11789 17578 CHECK SUNROSE MFA CORPORATION WALL HEATER 101-0000-42402 .0 $74.13 $74.13 12/28/15 R11789 17578 CHECK SUNROSE MFA CORPORATION WALL HEATER PC 101-0000-42600 0 $36.27 $36.27 12/28/15 R11789 17578 CHECK . . NROSE MFA " ON Total Paid for MECHANICAL: $866.98. $866.98. NEW CONSTRUCTION 101-0000-424000 $730.53 $730.53 12/28/15 R11789 17578 CHECK SUNROSE MFA PERMIT CORPORATION Total Paid for NEW CONSTRUCTION PERMIT: $730.53 $730.53 NEW CONSTRUCTION 101-0000-42600 0 $1,200.00 $1,200.00 10/6/15 R9791 17371 CHECK SUNROSE SGU PLAN CHECK CORPORATION NEW CONSTRUCTION 101-0000-42600 0 $355.32 $355.32 12/28/15 R11789 17578 CHECK SUNROSE MFA PLAN CHECK CORPORATION Total Paid for NEW CONSTRUCTION PLAN CHECK: $1,555.32 _ $1,555.32 BACKFLOW DEVICE 101-0000-42401 0 $12.09 $12.09 12/28/15 R11789 17578 CHECK SUNROSE MFA CORPORATION BACKFLOW DEVICE PC 101-0000-42600 0 $4.83 $4.83 12/28/15 R11789 17578 CHECK SUNROSE MFA CORPORATION BUILDING SEWER 101-0000-42401 0 $12.09 $12.09 12/28/15 R11789. 17578 CHECK SUNROSE MFA CORPORATION BUILDING SEWER PC 101-0000-42600 0 $12.09 $12.09 12/28/15 R11789 17578 CHECK SUNROSE MFA CORPORATION FIXTURE/TRAP 101-0000-42401 0 $338.52 $338.52 12/28/15 R11789 17578 CHECK SUNROSE MFA CORPORATION FIXTURE/TRAP PC 101-0000-42600 0 $338.52 $338.52 12/28/15 R11789 17578 CHECK SUNROSE MFA• CORPORATION GAS SYSTEM, 5+ 101-0000-42401 0 $36.26 $36.26 12/28/15 R11789 17578 CHECK SUNROSE MFA OUTLETS CORPORATION Printed: Monday, December 28, 2015 11:32:43 AM 5 of 8 CR SYST(H1S DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE RECEIPT # CHECK # METHOD PAID BY CLTD BY GAS SYSTEM, 5+ 101-0000-42600 0 $24.17 $24.17 12/28/15 R11789 17573 CHECK SUNROSE MFA OUTLETS PC CORPORATION ROOF DRAIN 101-0000-42401 0 $48.36 $48.36 12/28/15 R11789 17578 CHECK SUNROSE MFA CORPORATION ROOF DRAIN PC 101-0000-42600 0 $48.36 $48.36 12/28/15 R11789 17578 CHECK SUNROSE MFA CORPORATION WATER HEATER/VENT 101-0000-42401 0 $24.18 $24.18 12/28/15 R11789 17573 CHECK SUNROSE MFA CORPORATION WATER HEATER/VENT 101-0000-42600 0 $14.50 12/28/15 R11789 17578 CHECK SUNROSE MFA PC .$14.50 CORPORATION WATER SYSTEM. 101-0000-42401 0 $12.09 $12.09 12/28/15 R11789 17578 CHECK SUNROSE MFA INST/ALT/REP CORPORATION WATER SYSTEM 101-0000-42600 0 $12.09 $12.09 12/28/15 R11789 17578 CHECK SUNROSE MFA INST/ALT/REP PC CORPORATION . Total Paid for PLUMBING FEES: $938.15. $938.15 SMI - RESIDENTIAL 101-0000-20308 0 $60.56 $60.56 12/28/15 R11789 17578 CHECK SUNROSE MFA CORPORATION Total Paid for STRONG MOTION INSTRUMENTATION SMI: $60.56 $60.56 SINGLE FAMILY 224-0000-20320 0. $1,837.44 $1,837.44 12/28/15 R31789 17578 CHECK SUNROSE MFA DETACHED CORPORATION Total Paid for TUMF -RESIDENTIAL: $1,837.44 $1,837.44 TOTALS: $14,122.56 $14,i22.S6 PARENT PROJECTS Printed: Monday, December 28, 2015 11:32:43 AM 6 of 8'?srsrcMs 1ST BLDG STR (3' JOHN 10/6/2015 10/27/2015 10/29/2015 REVISIONS REQUIRED WK) THOMPSON NEED ENGINEER'S SIGNATURE ON THE PRECISE 1ST PW GREEN AMY YU 11/17/2015 11/24/2015 11/18/2015 REVISIONS REQUIRED GRADING PLAN. SHEET GREEN SHEET AND PG PLAN IN STEPHANIE'S INBOX 2ND PW GREEN 'SHEET AMY YU 11/19/2015 11/25/2015 11/19/2015 READY FOR APPROVAL 2ND BLDG NS (2 JIM JOHNSON 11/23/2015 12/9/2015 12/4/2015 APPROVED WK) 2ND BLDG STR (2 JOHN 11/23/2015 12/9/2015 12/8/2015 REVISIONS REQUIRED WK) . THOMPSON ` 3RD BLDG NS (2 WK) JIM JOHNSON 12/15/2015 1/4/2016 12/16/2015 APPROVED CONTACT YOUNG ENGINEERING TO SEE IF WE CAN.DO STRUCTUAL IN HOUSE. 3RD BLDG STR (2 JOHN 12/15/2015 1/4/2016 12/18/2015 READY FOR APPROVAL WK) THOMPSON BOND INFORMATION ATTACHMENTS -Attachment Type CREATED OWNER DESCRIPTION PATHNAME SUBDIR ETRAKIT ENABLED DOC 10/16/2015 JIM JOHNSON S3-459 VIA DONA.docx 53-459 VIA DONA.docx 0 2ND REVIEW - 2ND REVIEW - DOC 12/8/2015 JOHN THOMPSON STRUCTURAL STRUCTURAL 0 TRANSMITTAL.pdf TRANSMITTAL.pdf 2ND REVIEW - 2ND REVIEW - DOC 12/8/2015 JOHN THOMPSON STRUCTURAL STRUCTURAL 0 COMMENTS.doc COMMENTS.doc 3RD REVIEW - 3RD REVIEW - DOC 12/18/2015 JOHN THOMPSON STRUCTURAL STRUCTURAL 0 TRANSMITTAL.pdf TRANSMITTAL.pdf 1ST REVIEW - NEW CITY DOC 10/30/2015 KATHRYN SAMUELS STRUCTURAL TRANSMITTAL BRES 0 TRANSMITTAL 2015-0387 (lst).pdf Printed: Monday, December 28, 2015 11:32:43 AM 7 of 8 §SYSTEMS Permit Details PERMIT NUMBER City of La Quinta BRES2015 .�387 p . Printed: Monday, December 28, 2015 11:32:43 AM 8 of 8 C sysrrMs ATTACHMENTS Attachment Type CREATED OWNER DESCRIPTION PATHNAME SUBDIR ETRAKIT ENABLED 1ST REVIEW - Soils_ Report_Scope_BR DOC 10/30/2015 KATHRYN SAMUELS STRUCTURAL 0 COMMENTS (SOILS) ES 2015-0387.pdf 1ST REVIEW - DOC 10/30/2015 KATHRYN SAMUELS STRUCTURAL BRES 2015-0387 KS 0 (lst).doc COMMENTS DOC 12/18/2015 MARY FASANO School Fee Letter School Fee Letter 0 (53459 VIA DONA.docx (53459 VIA DONA.docx DOC 11/17/2015 STEPHANIE GUMPERT DEBRIS PLAN.pdf DEBRIS PLAN.pdf 0 ' SCHOOL FEE RECEIPT SCHOOL FEE RECEIPT DOC 12/22/2015 STEPHANIE GUMPERT 53459 VIA DONA 12-22- 53459 VIA DONA 12-22- 0 15.pdf 15.pdf PM 10 APPROVAL 12-1- PM 10 APPROVAL 12 -1 - DOC 12/1/2015 STEPHANIE KHATAMI 15 - 53459 VIA 15 - 53459 VIA 0 DONA.pdf DONA.pdf Printed: Monday, December 28, 2015 11:32:43 AM 8 of 8 C sysrrMs 13R,E5 2.6(5e-.038? 53 December 21, 2015 Mr. and Mrs. Scott Turban Re: Lot 42D at 53459 Via Dona Final Working Drawings #2 Dear Mr. and Mrs. Turban, This correspondence shall serve as notification that the Hideaway Design Review Committee (DRC) reviewed your revised final construction documents at the December 15, 2015 meeting. The project was approved to start construction subject to the following comments being addressed prior to framing starting at the home: 1. The construction plan and details were previously requested but have not yet been submitted as required. 2. Courtesy comment: The front yard planting consists of mostly short-lived plant material that will need frequent replacement which is not preferred in the front yard where visible to the street. 3. Decomposed granite and cobble can be utilized in accent areas but are not approved for use throughout the entire yard and/or at the property lines as a transitional planting design is required. Native soil and mulch are approved ground covers. 4. Cut sheets are required for the proposed landscape path ]fight. 5. The planting, lighting and irrigation plans were submitted for review; however, the construction plan and details were not provided but are required for final approval. 6. Please provide clouding and delta revision dates on all plan submittals for record keeping purposes. We look forward to working with you during the construction process. Please contact Brook Marshall at 760-219-8057 or by email at DRCFacilitator@gmail.com with any questions regarding this review or to schedule your Pre -Construction Meeting once a Building Permit has been received. As a reminder, final approvals are valid for a one-year period. Any changes to the plans should be submitted and should include revision deltas and dates. Sincerely, THE HIDEA WA Y DESIGN RE VIE W COMMITTEE By: /04q 15- �r Title�� Date: cc: stracts Proseed DRC He Pursuant to Cal. Civil Code, any rejection by the DRC may be appealed to the Board of Directors for the Association. Ifyou wish to pursue an appeal, please contact the Association's property manager directly. r Building Address Owner °---D2E�2� �S = o 3sl P.O. BOX 1504 APPLICATION ONLY 78-495 CALLE TAMPICO e4 Aovf— LA QUINTA, CALIFORNIA 92253 Mailing Address e (�20-,eo Address State Lic.' City & Classif. 6 3 � 1,� 7 � Lic. # Desi ner CTS A21G� p ILic. # LICENSED CONTRACTOR'S DECLARATION that I am livens under provisions of Chapter 9 (commencing with Section the Bus' nm Codgragd my llcensgris in full force anO — OWNER -BUILDER DECLARATION I hereby affirm that I am exempt from the Contractor's License Law for the following reason: (Sec. 7031.5, Business and Professions Code: Any city or county which requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions o/the Contrec- tor's License Law, Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, or that he is exempt therefrom, and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500). ❑ I, as owner of the property, or. my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. (Sec. 7044, Business and Profes- sions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he did not build or improve for the purpose of sale). ❑ I, as owner of the property, am exclusively contracting with licensed contractors to construct the project. (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who contracts for such projects with a contractors) licensed pursuant to the Contractor's License Law) ❑ 1 am exempt under Sec. B. & P.C. for this reason Date Owner WORKER'S COMPENSATION DECLARATION I hereby affirm that I have a certificate of consent to self -insure, or a certificate of Worker's Compensation Insurance, or a certified copy thereof. (Sec. 3800, Labor Code.) Policy No. Company ❑ Copy is filed with the city. ❑ Certified copy is hereby furnished. CERTIFICATE OF EXEMPTION FROM WORKERS' COMPENSATION INSURANCE (This section need not be completed if the permit is for one hundred dollars ($100) valuation or less). I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to Workers' Compensation Laws of California. Date Owner NOTICE TO APPLICANT: If, after making this Certificate of Exemption you should become subject to the Workers' Compensation provisions of the Labor Code, you must forthwith comply with such provisions or this permit shall be deemed revoked. CONSTRUCTION LENDING AGENCY I hereby affirm that there is a construction lending agency for the performance of the work for which this permit is issued. (Sec. 3097, Civil Code.) Lender's Name Lender's Address This is a building permit when properly filled out, signed and validated, and is subject to expiration if work thereunder is suspended for 180 days. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter the above-mentioned property for inspection purposes. Signature of applicant Date Mailing Address City, State, Zip WHITE = BUILDING DEPARTMENT BUILDING: TYPE C-O7NST. OCC. GRP. A.P. Number / /7, Legal Description �roject Description Sq. Ft. --I-No. No. Dw. Size 0 `J Stories Units New Add ❑ Alter ❑ Repair ❑ Demolition ❑ Estimated Valuation PERMIT AMOUNT Plan Chk. Dep. Plan Chk. Bal. Const. Mech.'" :� " a tE x ji r Electrical v r Plumbing S.M.I. Grading no Driveway Enc. Infrastructure CITY OF LA; Qv ITY DEVELOP 3 TOTAC CONTACT INFORMATION NAME: -,�,c�,cJ C,7 �j PHONE: 7G0 ip ZONE: BY: Minimum Setback Distance Front Setback from Center Line Rear Setback from Rear Prop. Line Side Street Setback from Center Line Side Setback from Property Line FINAL DATE INSPECTOR Issued by: Validated by: Validation: Date Permit YELLOW = APPLICANT PINK = FINANCE TTN: LA QUINTA, CALIFORNIA 92247-1504 78-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 BUILDING & SAFETY DEPARTMENT (760) 777-7125 FAX (760),777-7011 >(I OUNG ❑ESGIL ❑VCA []COMPLETE PLAN CHECK/N/S-STRUCTURAL ODAY'S DATE: to -w (9 -- r < DUE DATE: ERMIT NUMBER: RLS SUI S77 039"1 ROJECTADDRESS: 53q -rcl OR lir PPLICANT NAME: rl.� UBMITTAL ROUND: S BIN NUMBER: S. CLUDED HEREWITH: S ❑REDLINED PLANS UCT ❑REDLINED STRUCT USS ❑REDLINED TRUSS SOILS ❑REDLINED SOILS ENERGY ❑REVISED ENERGY CORRECTION LIST OTHER ❑REVISED PLANS ❑REVISED STRUCT ❑REVISED TRUSS ❑REVISED SOILS []APPROVED PLANS ❑APPROVED STRUCT []APPROVED TRUSS ❑APPROVED SOILS ❑CUSTOMER RESPONSES -BUILDING DEPARTMENT USE ONLY- EEN SHEET TO: ❑CDD ❑(w/Plans) [-]PUBLIC WORKS ❑COVE CHECK (w/Application) IGN NON-STRUCTURAL TO: womw MENTS: L____- __ YOUNG ENGINEERING 3 'E Pv/oss JffPThT(R_ 011 Letter of Transmittal City of La Quinta Today's Date:. ' 10-39'15 78-495 Calle Tampico City Due Date: La Quinta, CA 92253 Project Address: 53459 Via Dona Kay Plan Check #: 2015-0387 ' Submittal: 1m [] 4* ' ` -- ' -- LJ �m . LJ - 'If you have any questions, Please call. This Material Sent for: Fl Your Files LJ Your Review Checking Othmr[] ' Z Per Your Request ' FlApproval El ' @* the request of: ` ' By: Kathryn Samuels Palm Desert Office: (760 Other� Fl . � OCT 2 9y015 ` CITY OFLAQUDNTA 5�, O 3m , [] Other: ' VVmare forwarding: By Messenger [] ByMail (Fe dEumvUPS) [] Your Pickup Includes: #0f Descriptions: Includes: #Of Descriptions: Copies: Copies: ' L] Structural, � ` El`� � Revised S�uc�ndPlans ---------- 1 S�ucb�na|�a�u�Uonu --------- [] . Rmv�ed8huct. Co|co El Truss Calculations Floor [] ` ReviuedTruuu and Roof [] Soils Report [] Revised Soils Report 1[] __--_-_-_ Structural 1 Redlined Plans ' ElA Approved |[� | [] Redlined Structural Ca|cm .[] Approved TCales [] ---_---_- Redlined []� ' Approved S i( Report []��[] ` _-_----_ --------- +` 'Other: Comments: Structural content is not awrovable. Please refer to comment list. 'If you have any questions, Please call. This Material Sent for: Fl Your Files LJ Your Review Checking Othmr[] ' Z Per Your Request ' FlApproval El ' @* the request of: ` ' By: Kathryn Samuels Palm Desert Office: (760 Other� Fl . � OCT 2 9y015 ` CITY OFLAQUDNTA COMMUNITY DEVELOPMENT DEPARTMENT 78-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 (7.60) 777-7125 FAX (760) 777-7011 RESIDENTIAL PLAN CHECK CORRECTION LIST (os) DATE: 10/16/2015 STATUS: FIRST REVIEW PLAN CHECKED BY: JIM JOHNSON TELEPHONE NUMBER: (760) 777-7130 ADDRESS: 53-459 UIQ ONA DESCRIPTION: NEW SFD APPLICANT: TURBAN PLAN CHECK #: BRES2015-0387 This submittal has been checked for compliance with the 2013 California Residential, Mechanical, Electrical, Plumbing, Energy, and Green Building Codes, and the City of La Quinta Municipal Code. APPLICANT: BUILDING DEPARTMENT STAFF: The following items are being returned to you for DO NOT accept any resubmittal unless ALL of the correction: following items are included: 2 SETS OF PLANS 2SETS TITLE -24 2 SETS STRUC CALCS THIS CORRECTION LIST REDLINED SETS 2 NEW REVISED SETS 2 SETS STRUC CALCS 2 SETS TRUSS CALCS 2 SETS TTILE -24 THIS CORRECTION LIST / RESPONSES P.M. 10 & BURRTEC WASTE PLANS FIRE DEPT APPROVAL (SPRINKLERS) INSTRUCTIONS TO APPLICANT: 1) Provide a written response to each comment on the following pages, noting specifically where the correction can be found. Responses such as, "Sheet A-3," or, "Handrails shall be per CBC Section 1003," are not acceptable. Show or note specifically how compliance with a code requirement is achieved. Responses such as, "Added note 16 on sheet A-3" are appropriate and will help expedite your back check. 2) Corrections may not be made by handwriting on existing drawings. Revise originals and reprint Plans and/or Calculations as necessary. 3) Return all red -marked Plans and/or Calculations with your resubmittal. 4) Each sheet of resubmitted Plans and/or Calculations shall include the preparer's name and telephone number and shall be wet -signed by the preparer. If the preparer is a licensed architect or engineer, all documents prepared by that licensed individual shall also bear his/her stamp as prescribed by California Business and Professions Code Section 5536. Resubmittals will not be accepted with signatures missing. 5) Return this list, your written responses, and all documents listed above with your resubmittal. Residential Plan Check Correction List Page 1 of 4 SECTION A - GENERAL 1) Sheet Index does not reflect actual sheets in Plans. Reconcile. 2) Provide the Project Address on the first sheet of Plans. 3) Provide on each sheet of resubmitted Plans and cover sheet of bound Calculations the preparer's name and telephone number and wet -signature. If the preparer is a licensed architect or engineer, all documents prepared by that licensed individual shall also bear his/her stamp as prescribed by California Business and Professions Code §5536. Resubmittals will not be accepted with signatures missing. 4) Provide written evidence from Burrtec Waste, approving a waste management plan that diverts not less than 50% of the construction materials from landfill for the, project. Contact the District Environmental Coordinator directly at (760) 578-5215 for free assistance with the preparation of this plan. SECTION C - ARCHITECTURAL 1) Show on Floor Plan or Window Schedule all locations of windows requiring safety glazing. (CRC §R308.4) See Floor Plan for area(s) WINDOW ON STAIRWAY 2) Provide attic access opening(s) not less than 22" x 30". Access shall be located in a corridor, hallway or other readily accessible location. Access is required in all attic spaces that exceed 30 square feet in area and have a vertical height of 30 inches (measured from the top of ceiling framing members to the underside of roof framing members). Thirty -inch minimum unobstructed headroom in the attic space shall be provided at or above the access opening. (CRC §R807.1) Show all locations on Plan. SECTION E — ELECTRICAL 1) Provide on the plan location of electrical sub -panels. (CRC §R106.1.1) 2) Provide 120 -volt smoke alarm(s). (CRC §R314.4) Show all locations on Plans. Informational Item: In dwelling units, single- or multiple station smoke alarms shall be installed and maintained at all of the following locations: 1. On the ceiling or wall outside of each separate sleeping area in the immediate vicinity of bedrooms. 3) Provide 120 -volt carbon monoxide alarm(s). (CRC §R315.1.1) Show all locations on Plans. Informational Item: In dwelling units and in sleeping units within which fuel -burning appliances are installed and in dwelling units that have attached garages an approved carbon monoxide alarm shall be installed at all of the following locations: 1. On the ceiling or wall outside of each separate sleeping area in the immediate vicinity of bedrooms. SECTION G — ENERGY EFFICIENCY 1) Conditioned floor area on Plans does not match Energy Calculations. Reconcile. Informational Items: Conditioned floor area (CFA) is the total floor area (in square feet) of enclosed conditioned space on all floors of a building, as measured at the floor level of the exterior surfaces of exterior walls Residential Plan Check Correction List Page 2 of 4 f City of La Quinta enclosing the conditioned space. [§101] This term is also referred to in the standards simply as the floor area. This is an important value.for the purpose of compliance since annual energy use is divided by this value to obtain the energy budget. CFA is calculated from the plan dimensions of the building including the floor area of all conditioned and indirectly conditioned space on all floors. It includes lofts and mezzanines but does not include covered walkways, open roofed -over areas, porches; pipe trenches, exterior terraces or steps, chimneys, roof overhangs or parking garages. Unheated basements or closets for central gas forced air furnaces are also not included unless shown to be indirectly conditioned. The floor area of an interior stairway is determined as the CFA beneath the stairs and the tread area of the stairs themselves. (Residential Compliance Manual § 1.8 Conditioned Floor Area) SECTION I - STRUCTURAL 1) See separate structural correction list, attached. Important note to Engineer of Record: If these corrections require revisions to structural calculations, in response to these corrections, do NOT simply submit two copies of a few supplemental calculations. For resubmittal, include: • One complete set of structural calculations from the previous. submittal, and... • Two complete, stamped and wet -signed sets of structural calculations for review and approval. Your written responses should direct the plan reviewer to the appropriate revised page(s). Failure to provide documentation in this manner will delay approval of your client's project. Incomplete sets, loose pages will not be assembled by the Building Department. Important note: If manufactured truss products are used on this project, be aware that the City of La Quinta does not allow deferred submittals. Truss calculations are required no later than the second submittal. SECTION J — SOIL / FOUNDATION 1) See separate structural correction list, attached. SECTION K - MISCELLANEOUS COMMENTS I) Red marks on Plans, even if not specifically mentioned in this list, indicate items needing correction. Revise Plans as necessary and provide written response, noting where correction can be found. 2) Provide a copy of the Grant Deed (or other legal document) for this property, verifying the legal description and Assessor's Parcel Number. 3) Provide one copy each of the Site Plan and Floor Plan for the County Assessor's office. While not required for resubmittal, this administrative item must be addressed prior to issuance of building permit. 4) Provide letter of approval from Homeowners' Association. 5) Inadequate information has been provided at this submittal to calculate fees for this project. Fee calculation will be performed when'Plans are complete. END.CORRECTION LIST As further information is provided and reviewed, additional corrections may be required. Residential Plan Check Correction List Page 3 of 4 City of La Quinta Residential Plan Check Correction List Page 4 of 4 s• City of La Quinta Building and Safety Department Plan Check Corrections Str_u�u�ral Turban Residence Engineer: Benjamin J. Seibel, P.E. 53459 Via Dona Plan Check No.: BRES 2015-0387 (15t check) La Quinta, California Date: 10/29/15 1. Structural plans/details must be signed by a licensed engineer or architect licensed in the State of California. 2. Provide a current site specific soils report for this project, and reference it on the structural plans. The soils report shall address all City requirements as per the City Memorandum attached to this comment list. 3. Provide soil testing report for soluble sulfate levels in the soil for verification of adequacy of concrete strength and type. If report is not available, specify on structural plan to test soil for soluble sulfate prior to pour. Provide a table specifying the concrete strength and type for the different levels of soluble sulfate. Refer to ACI 318-11, 4.2 and 4.3. Or specify Type V, 4500 PSI concrete. 4. Truss calculations for metal plate connected wood trusses may not be a deferred submittal. Provide truss calculations with resubmittal. The Engineer of Record shall issue a letter of review and approval to the Building official or affix a shop drawing stamp on the truss calculations stating reviewed and accepted. 5. At all exterior walls with hardscape in contact, provide a minimum 2" clearance for weep screed. At the loggia, the hardscape is flush with FF. CBC 2013 2512.1.2. 6. Per ICC Report ESR -2316 Section 4.2, installation of new isokern fireplaces are limited to SDC A and B. For SDC D, structural calculations and details are required for the foundation and anchorage. Seismic analysis shall comply with ASCE 7-10 Chapter 13. 7. For the City of La Quinta, revise wind exposure category to 'C'. 8. Specify minimum dimensions of all grade beam footings for Simpson SB walls. 9. Respond to all redlines on structural plans. If corrections require revisions to the structural calculations, provide one complete copy of the redlined calculations from this submittal plus two complete, bound copies of the revised calculations for review and approval. Providing only a few supplemental, revised pages will not be accepted and will delay approval of this project. Return all redlined structural plans and calculations at resubmittal. Please incorporate requested corrections into plan sets and reprint. Plan Reviewer. John Thompson, P.E. Phone No.: 760-772-5107 REC!':b`tD OCT 2 9 2015 CI7Y Cs" -, QW NTA COMMUNITY DEVELOPMENT DATE: 12/9/2015 Tjhf 4 4Quinra COMMUNITY DEVELOPMENT DEPARTMENT 78-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 (760) 777-7125 FAX (760) 777-7011 RESIDENTIAL PLAN CHECK CORRECTION LIST (os) STATUS: 2ND. REVIEW PLAN CHECKED BY: JIM JOHNSON TELEPHONE NUMBER: (760) 777-7130 ADDRESS: 53-459 VAI DONA DESCRIPTION: NEW SFD APPLICANT: TURBAN PLAN CHECK #: BRES2015-0387 This submittal has been checked for compliance with the 2013 California Residential, Mechanical, Electrical, Plumbing, Energy, and Green Building Codes, and the City of La Quinta Municipal Code. APPLICANT: BUILDING DEPARTMENT STAFF: The following items are being returned to you for DO NOT accept any resubmittal unless ALL of the correction: following items are included: 2 SETS OF PLANS 2SETS TITLE -24 2 SETS STRUC CALCS THIS CORRECTION LIST REDLINED SETS 2 NEW REVISED SETS 2 SETS STRUC CALCS 2 SETS TRUSS CALCS 2 SETS TTILE -24 THIS CORRECTION LIST / RESPONSES FIRE DEPT APPROVAL (SPRINKLERS) INSTRUCTIONS TO APPLICANT: 1) Provide a written response to each comment on the following pages, noting specifically where the correction can be found. Responses such as, "Sheet A-3," or, "Handrails shall be per CBC Section 1003," are not acceptable. Show or note specifically how compliance with a code requirement is achieved. Responses such as, "Added note 16 on sheet A-3" are appropriate and will help expedite your back check. 2) Corrections may not be made by handwriting on existing drawings. Revise originals and reprint Plans and/or Calculations as necessary. 3) Return all red -marked Plans and/or Calculations with your resubmittal. 4) Each sheet of resubmitted Plans and/or Calculations shall include the preparer's name and telephone number and shall be wet -signed by the preparer. If the preparer is a licensed architect or engineer, all documents prepared by that licensed individual shall also bear his/her stamp as prescribed by California Business and Professions Code Section 5536. Resubmittals will not be accepted with signatures missing. 5) Return this list, your written responses, and all documents listed above with your resubmittal. Residential Plan Check Correction List Pagel of 2 SECTION A — GENERAL ( NON STRUC APPROVED) WASTE MANAGEMENT PLAN NOT APPROVED SECTION I - STRUCTURAL 1) See separate structural correction list, attached. Important note to Engineer of Record: If these corrections require revisions to structural calculations, in response to these corrections, do NOT simply submit two copies of a few supplemental calculations. For resubmittal, include: • One complete set of structural calculations from the previous submittal, and... • Two complete, stamped and wet -signed sets of structural calculations for review and approval. Your written responses should direct the plan reviewer to the appropriate revised page(s). Failure to provide documentation in this manner will delay approval of your client's project. Incomplete sets, loose pages will not be assembled by the Building Department. Important note: If manufactured truss products are used on this project, be aware that the City of La Quinta does not allow deferred submittals. Truss calculations are required no later than the second submittal. SECTION J — SOIL / FOUNDATION 1) See separate structural correction list, attached. SECTION K - MISCELLANEOUS COMMENTS 1) Red marks on Plans, even if not specifically mentioned in this list, indicate items needing correction. Revise Plans as necessary and provide written response, noting where correction can be found. 2) Provide one copy each of the Site Plan and Floor Plan for the County Assessor's office. While not required for resubmittal, this administrative item must be addressed prior to issuance of building permit. 3) Provide letter of approval from Homeowners' Association. END CORRECTION LIST As further information is provided and reviewed, additional corrections may be required. Residential Plan Check Correction List Page 2 of 2 City of La Quinta Building and Safety Department Plan Check'Corrections Turban Residence Engineer: Benjamin J. Seibel, P.E. 53459 Via Dona Plan Check No.: BRES 2015-0387 (2"d check). La Quinta, California Date: 12/8/15 RdiVL_ ung<5tructural Plan Ctieck Comments ; 4. Truss calculations for metal plate connected wood trusses may not. be a deferred submittal. Provide truss calculations with resubmittal. The Engineer of Record shall issue a letter of review and approval to the Building official or affix a shop drawing stamp on the, truss calculations stating reviewed and 7. For the City of La Quinta, revise wind exposure category to 'C': ReRevnd;EzposureUnofe�onplan sheetsSP1.: , 8. Specify minimum dimensions of all grade beam footings for Simpson SB walls RRewew min�mumrequiretlu"Wd�mens�on for�footmgsatSBwalls Manufacturer:, Vh35"min ditions Revise fountlatron plan of lanchorage designfor panelkkancho sbasedonAC131x811; ApenalixD Call soutf 9. Respond to all redlines on structural plans. how footing uptlewallbeiween Casctving If corrections require revisions to the structural calculations, provide one complete copy of the redlined calculations'from this submittal plus two complete, bound copies of the revised calculations for review and approval. Providing only a few supplemental, revised pages will not be accepted and will delay approval of this project. Please incorporate requested corrections into.plan sets and reprint. Plan Reviewer: John Thompson, P.E. Phone No.: 760-772-5107 00'0 - TO: kfYOUNG ATTN: LA QUINTA, CALIFORNIA 92247-1504 78-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 TRANSMITTAL ❑ESGIL - '❑VCA BUILDING & SAFETY DEPARTMENT (760)777-7125 FAX (760) 777-7011 ❑COMPLETE PLAN CHECK/N/S-STRUCTURAL- TODAY'S DATE: 1, ` DUE DATE: A3AP PERMIT NUMBER: V 5 1947 PROJECT ADDRESS:151- 4 5 -/ V/ 71bNtA APPLICANT NAME: ! Ci�e A AI*J SUBMITTAL ROUND: BIN NUMBER: 56*4 D INCLUDED HEREWITH: ❑PLANS ❑REDLINED PLANS ❑STRUCT VEEDLINED STRUCT" � S� �� TRUSS • • ER' ❑SOILS ❑REDLINED SOILS ❑ENERGY ❑REVISED ENERGY CORRECTION LIST ❑OTHER ❑RLVISED PLANS VISED STRUCT ❑REVISED TRUSS ❑REVISED SOILS ❑APPROVED PLANS ❑APPROVED STRUCT ❑APPROVED TRUSS ❑APPROVED SOILS trilsooTOMER RESPONSES -BUILDING DEPARTMENT USE ONLY - GREEN SHEET TO: ❑CDD ❑(w/Plans) ❑PUBLIC WORKS []COVE CHECK (w/Application) ASSIGN NON-STRUCTURAL.TO: COMMENTS: fli Letter of Transmittal To: City of La Quinta Today's Date: 12-18-15 78-495 Calle Tampico City Due Date: ASAP La Quinta, CA 92253 Project Address: 53-459 Via Dona Attn: Kay / Jim Plan Check M BRES2015-0387 Submittal:. ❑ 1st ❑ 4th ❑ 2nd ❑ 5th ® 3rd ❑ Other: We are forwarding: ® By Messenger ❑ By Mail (Fed Ex or UPS) ❑ Your Pickup Includes: Descriptions: Includes: # Of Descriptions: Copies: ❑ Structural Plans ® 1 Revised Struct. Plans ❑ Structural Calculations ® 1 Revised Struct. Calcs ® 1 Truss Calcs ❑ . Revised Truss.Calcs ❑ Soils Report ❑' Revised Soils Report ® 1 Structural P/C. ❑ Approved Structural Plans Comments/Responses ® 1 Redlined Structural Plans ❑ Approved Structural Calcs ® 1 Redlined Structural Calcs ❑ Approved Truss Calcs ❑ Redlined Truss Calcs, ❑ Approved Soils Report ❑ Redlined Soils Reports ® 1 Other: 2nd Sub. Struct Plans Comments: Structural content is approvable. Structural Plan Review Time = 1.5 HR This Material Sent for: ❑ Your Files ® Per Your Request ❑ Your Review ❑ Approval ❑ Checking ❑ At the request of: Other: ❑ By: John W. Thompson' KCUL-1VELJ Office: ® (760) 772-5107 Other: ❑ DEC 19 2015 CITY OF LA QUINTA COMMUNITY 1)EVEL0pMeNT To: Attn: Structural Plan Review Time = 4.0 HR This Material Sent for: ❑ Your Files, Per Your Request ❑ Your Review ❑ Approval ❑ Checking ❑ At the request of: Other: ❑ By: John W. Thompson Office (760) 772-5107 Other: ❑ RE' Lu, DEC 0 D 2015 CITY OF LA QUINTA COMMUNITY DEVELOPMENT Submittal: ❑ 1st ❑ 4th ED 2nd ❑ 5th ❑ 3d ❑ Other: We are forwarding: By Messenger ❑ By Mail (Fed Ex or UPS) ❑ Your Pickup Includes: Descriptions: Includes: # Of Descriptions: Copies: ❑ Structural Plans 1 Revised Struct.'Plans ❑ Structural Calculations 1 Revised Struct. Calcs 1 Truss Calcs ❑ Revised Truss Calcs 1 Soils Report ❑ Revised Soils Report 1 Structural P/C Comments ❑ Approved Structural Plans i Redlined, Structural Plans ❑ Approved Structural Calcs 1 Redlined Structural Calcs ❑ Approved Truss Calcs, ❑ Redlined Truss C,alcs ❑ Approved Soils Report ❑ Redlined Soils Reports ❑ Other: Comments: Structural content is not approvable see attached remaining structural plan check comment list. Structural Plan Review Time = 4.0 HR This Material Sent for: ❑ Your Files, Per Your Request ❑ Your Review ❑ Approval ❑ Checking ❑ At the request of: Other: ❑ By: John W. Thompson Office (760) 772-5107 Other: ❑ RE' Lu, DEC 0 D 2015 CITY OF LA QUINTA COMMUNITY DEVELOPMENT 4 LA QUINTA, CALIFORNIA 92247-1504 78-495 CALLS TAMPICO LA QUINTA, CALIFORNIA 92253 TRANSMITTAL BUILDING & SAFETY DEPARTMENT (760) 777-7125 FAX (760) 777-7011 TO: X OUNG ❑ESGIL ❑VCA ❑COMPLETE PLAN CHECK/N/S-STRUCTURAL ATTN: TODAY'S DATE: -11 -7.3 -IS DUE DATE: l /57 PERMIT NUMBER: pptes ZA�s"0387 PROJECT ADDRESS: � � IIA Ao/M APPLICANT NAME: SUBMITTAL ROUND: ZM� INCLUDED HEREWITH: ❑PLANS WEDLINED PLANS ❑STRUCT XREDLINED STRUCT RUSS ❑REDLINED TRUSS SOILS ❑REDLINED SOILS ❑ENERGY ❑REVISED ENERGY XCORRECTION LIST ❑OTHER BIN NUMBER: ST(J►a� *EVISED PLANS KEVISED STRUCT ❑REVISED TRUSS ❑REVISED SOILS ❑APPROVED PLANS ❑APPROVED STRUCT []APPROVED TRUSS ❑APPROVED SOILS XCUSTOMER. RESPONSES -BUILDING DEPARTMENT USE ONLY - GREEN SHEET TO: ❑CDD ❑(w/Plans) ❑PUBLIC WORKS ❑COVE CHECK (w/Application) ASSIGN NON-STRUCTURAL TO: COMMENTS: RE: Turban Residence Hideaway Lot42D 52-791 Via Savona Plan Check No.: BRES2015-0387 SECTION A - GENERAL 1. The sheet index has been revised to show the correct sheets included in the submittal set. 2. Project address has been added to the title block. 3. All sheets have be signed by the preparer. 4. This has been included in the submittal set. SECTION C - ARCHITECTURAL 1. Window NN at stairway has been noted at Tempered see floor plan sheet 2 and schedule sheet 8. 2. Attic access have been added to the plans and casita closet, garage storage, and second floor. See floor plan sheets 1 and 2. SECTION E - ELECTRICAL All required sub -panels are shown on the plans - See first floor electrical plan sheet 3. Exterior next to master closet, Garage. 2. Smoke/carbon monoxide alarm have been added to the garage hall. SECTION G — ENERGY EFFICIENCY Calculations have been revised with correct footage. SECTION I - STRUCTURAL See response letter by structural engineer. All red marked on the original plan check submittal Set have been Included in the re -submittal sets. If you have any questions regarding the plan check, please do not hesitate to cal! �®Thank You, RECIEW Ron James Jr. 2015 Project Manager ron@stracts.com ctu D VES �ENt coN1m STRACTSINIC ARCHITECTURE + IMERIOR DESIGN 550 S. OLEANDER ROAD PALM SPRINGS, CA 92264 1 PHONE 760.636.8951 FAX 760.778.1314 COMMUNITY DEVELOPMENT DEPARTMENT 78-495 CAL -LE TAMPICO LA QUINTA, CALIFORNIA 92253 (760) 777-7012 FAX (760) 777-7011 CERTIFICATION OF BUILDING AREA STREET ADDRESS OF JOB: 53459 VIA DONA APN: 777-420-025 DESCRIPTION OF WORK: "NEW SINGLE FAMILY RESIDENCE SQUARE FOOTAGE: 5,095 LF OWNER'S NAME: SCOTT TURBAN For questions regarding this letter, please call: City of La Quinta Permit Center (760) 777-7012 Coachella Valley Unified School District 83-733 Avenue 55 P O Box 847 Thermal, CA 92274 (760) 398-5909 Desert Sands Unified School District 47-950 Dune Palms Road La Quinta, CA 92253 (760) 771-8515 CITY OF LA QUINTA BUILDING & SAFETY DEPT. APPROVED FOR CONSTRUCTION DATE I )- 1 ` 6 BY Please note: This letter verifies conditioned square footage. Please call your School District to verify school fees, requirement for cashier's check or money order and hours of operation. ADDRESS rj 3 - 5 9 0,k) Pr PROJECT DESCRIPTION N � New Construction CONDITIONED/AC (SF) O GARAGE/UNCOND (SF) �, } 3S I00 / PATIO/COVERED (SF) 3 FIRE SPRINKLER (SF) CODE EDITION 2, 1-;, CONSTRUCTION TYPE v q� GOOD aES/ NO NUMBER OF FLOORS NUMBER OF BEDROOMS NUMBER OF UNITS . OCCUPANT LOAD llfi . OCCUPANCY P,-5 U MSHCP (DU/ACRE) twj)ke .(DWELLING UNITS PER ACRE, EX: 43,560SF/7,000SF Lot = 6.22DU/AT Remodel/Addition REMODEL AREA (SF) ' ADDITION AREA (SF) AWNING/CANOPY (EA BALCONY ADDITION (EA) FIREPLACE (EA) PARTITION (EA) STUCCO APPLICATION (SF) DOOR/WINDOW - REP (EA) DOOR/WINDOW - NEW (EA) CARPORT (EA) VALUATION ($) 1-1 (AS SHOWN ON BUILDING APPLICATION) Grading TRACT ❑ CUSTOM- HOME < = 7KSF ❑ CUSTOM HOME > 7KSF Nz�S 2o/S-038,7 APPLICATION DATE Mechanical FURNACE HEATER APPLIANCE (ALT/ADD) COMPRESSOR AIR HANDLER EVAP COOLER VENT FAN EXHAUST HOOD MISC MECHANICAL Units S. .Electrical Units NEW ELECTRICAL (SF) G U . and/or RECEP/SWITCH/LIGHT plus APPLIANCE - RES APPLIANCE - NONRES POWER APPARATUS SIGNS SERVICE TEMPORARY SERVICE MISC ELECTRICAL LIGHT POLES PV SYSTEM - ARRAY PV SYSTEM - MISC EQ Plumbing Units FIXTURE/TRAP SEWER SEPTIC ROOF DRAIN WATER HEATER GREASEINTERCEPTOR WATER PIPING BACKFLOW . GAS OUTLETS REVISED: 7/15/2015 RESIDENTIAL' 'Unit Counts MY TOILETS BIDET/URINAL SHOWERS I 1 BATHTUBS ' 1 SINKSLT BAR SINK 3 fit BBQ I o OVEN RANGE COOKTOP DRINKING FOUNTAIN WASHER DRYER e WATER HEATER ROOF DRAINS FLOOR DRAINS KITCHEN SINK VEGGIE SINK �% o LAUNDRY SINK FIREPLACE 111 REVISED: 7/15/2015 RESIDENTIAL Building Permit Number: Project Description: ISFR. Exempt: ❑ (Materials may contain hazardous wastes and are not subject to recycling provisions) Construction Debris Management Plan l Plan Submittal Date 11/9/2015 Job Site Address 53459 Via Dona r Owners Name Mr. and Mrs. Turban c/o Sunrose Corporation Number, Street, or PO Box 40101 Monterey Avenue Suite B1-214 1 City, state, Postal Code Rancho Mirage, CA 92270 �/ Owner's Phone Number /�/'" Owner's E -Mail Address Project Manager's Name Mike Tuvell j - Project Managers Phone Number 760-702-0119 Project Managers E-mail Address sunrose.sedona(a gmail.com D�O�e/ L Builder/ Contractor Sunrose Corporation Number, Street or PO Box 40101 Monterey Avenue, Suite B1-214 ((ff City, State, Postal Code Rancho Mirage, CA 92270 Project Square Footage 6,810 City Approval By Date of City Approval rials To Be Discarded: Product Tons Trash 12.94 Not recyclable Product Tons Asphalt 0.00 Recyclable Masonry (broken) 0.00 Brick/Block 0.00 Recyclable.. Plaster 1.36 Cardboard 2.25 Recyclable Scrap Metal 0.00 Commingled 0.00 Recyclable Tile (floor) 1.16 Concrete 0.54 Recyclable Tile (rood 0.00 Drywall 0.40 Recyclable Wood 17.02 Donated / Reuse" 0.00 Recyclable Landscape Debris 0.00 "Describe Items !t Totals: Recycle Trash Projected Diversion: 22.71 J 12.9 1 63.7% I understand it is the property owner's responsibility to submit copies of weight tickets or receipts to the District Environmental Coordinator as these hauls occur. I hereby certify that completion, implementation and adherence of the Debris Management Plan (DMP) for the above named project shall guarantee that at least 50% of the jobsite waste is diverted from landfilling. The remaining material will be recycled or reused. I will divert, for recycling or re -use, remaining materials generated from the first day of the project through the completion of the project in accordance with this plan. This DMP is issued in the name of the property owner(s) and shall remain their property throughout the construction and/or demolition project. A contractor serving as agent of the owner may obtain a DMP for the owner. However, the DMP is still issued in the name of the property owner(s) and the owner retains legal responsibility for ensuring that the provisions of the DMP are adhered to. The property owner(s) and general contractor shall be kept informed of the diversion progress through bi-monthly reports. If self -hauling, all refuse material from this project site must be taken to an approved recycler or transfer �sta ion. CIZ _v 7���� ,Owner / De v to err//"Project Manager / Superintendents Date Construction Debris Management Plan Summary of Requirements As of January 1, 2011, The Green Building Standards Code (CALGreen) requires that the construction of most new structures in the State of California comply with sections 4.408 and 5.408 of the code in accordance with Assembly Bill 939 requiring that no more than 50% of jobsite waste be disposed of as trash at local land fill sites and transfer stations. Exceptions may be made for certain projects under certain conditions. The City of La Quinta is committed to the highest level of environmental respect, to conserving our precious natural resources and setting an example to provide for a better world for generations to come. Recycling helps keep reusable resources out of landfills and will also reduce disposal costs. IMPORTANT: Burrtec Waste & Recycling Services is the City's franchise haulers. If you choose to self -haul any recyclables or trash, you must provide copies of all weight tickets and/or receipts from the transfer station, landfill, or recycler as the job progresses. Clean-up companies and other haulers are not permitted to haul waste or recyclables from the City of La Quinta. Self -haul weight tickets should be submitted to: Kenn Stevens, District Environmental Coordinator - kstevens@burrtecdesert.com, or faxed to (760) 340-0417, or mailed to: 41575 Eclectic Street, Palm Desert, Ca 92260. Coachella Valley Unified School District 83-733 Avenue'55, Thermal, CA 92274 (760) 398-5909 — Fax (760) 398-1224 This Box For District Use Only DEVELOPER FEES PAID AREA: AMOUNT LEVELONEAMOUNT: LEVEL TWO AMOUNT: MITIGATION AMOUNT: COMMAND. AMOUNT: DATE: RECEIPT: CHECK #: INITIALS CERTIFICATE OF COMPLIANCE (California Education Code 17620) Project Name: he Hideaway Date: December 22, 2015 Owner's Name: Scott Turban Phone No. 760-773-6633 Project Address: 53459 Via Dona, LaQuinta Project Description: New Single Family Dwelling APN: 777-420-025 Tract #: Lot #'s: Type of Development: Residential !XX! Commercial Industrial Total Square Feet of Building Area: Certification of Applicant/Owners: The person signing certifies that the above information is correct and makes this statement under penalty of perjury and further represents that he/she is authorized to sign on behalf of the owner/developer. Dated: December 22, 2015 Signature: SCHOOL DISTRICT'S REQUIREMENTS FOR THE ABOVE PROJECT HAVE BEEN OR WILL BE SATISFIED IN ACCORDANCE WITH ONE OF THE FOLLOWING: (CIRCLE ONE) Education Code 17620 Number of Sq.Ft. Amount per Sq.Ft. Amount Collected Gov. Code 65995 5095 $3.36 $17119.20 Project Agreement Existing Not Subject to Fee Approval Prior to 1/1/87 Requirement Building Permit Application Completed: Yes/No By: Elsa F. Esqueda, Director of Facilities and Maintenance Note: Pursuant to AB 181 any room additions or enclosures of 500 sq. ft. or less are exempt from developer fees. Any mobile homes being relocated within the same school district's jurisdiction are exempt from developer fees. Certificate issued by: Laurie Howard, Secretary Signature: � -4 ��" NOTICE OF 90 DAY PERIOD FOR PROTEST OF FEES AND STATEMENT OF FEES Section 66020 of the Government Code asserted by Assembly Bill 3081, effective January 1, 1997, requires that this District provide (1) a written notice to the project appellant, at the time of payment of school fees, mitigation payment or other exactions ("Fees"), of the 90 -day period to protest the imposition of these Fees and (2) the amount of the fees. Therefore, in accordance with section 66020 of the Government code and other applicable law, this Notice shall serve to advise you that the 90 -day protest period in regard to such Fees or the validity thereof, commences with the payment of the fees or performance of any other requirements as described in section 66020 of the Government code. Additionally, the amount of the fees imposed is as herein set forth, whether payable at this time or in whole or in part prior to issuance of a Certificate of Occupancy. As in the latter, the 90 days starts on the date hereof. This Certificate of Compliance is valid for thirty (30) days from the date of issuance. Extension will be granted only for good cause, as determined by the School District, and up to three (3) such extensions may be granted. MV:eJmydocs`derfees.'certiticate of compliance form updated 3-2007 11/2010 'i. COMMUNITY .DEVELOPMENT DEPARTMENT 78-495 CALLS TAMPICO LA QUINTA, CALIFORNIA 92253 (760) 777-7012 FAX (760) 777-7011 CERTIFICATION,OF BUILDING AREA STREET ADDRESS OF JOB: 53459 VIA DONA APN: 777-420-025 DESCRIPTION OF WORK: NEW SINGLE FAMILY RESIDENCE SQUARE FOOTAGE: 5,095 LF OWNER'S NAME: SCOTT TURBAN For questions regarding this letter, please call: City of La Quinta Permit Center (760) 777-7012 Coachella Valley Unified School District 83-733 Avenue 55 .P O Box 847 Thermal, CA 92274 (760) 398-5909 Desert Sands Unified School District 47-950 Dune Palms Road La Quinta, CA 92253 (760) 771-8515 E U LDING & SAFETY DEPT. - APPROVED FOR CONSTRUCTION DATE I"G _/ l�Y . R�'1-,1 Please note: This letter verifies conditioned square footage. Please call your School District to verify school fees, requirement for cashier's check or money order and hours of operation. • i32�� 201 -a3s� CITY OF LA QUINTA - PUBLIC WORKS DEPARTMENT GREEN SHEET PUBLIC WORKS CLEARANCE FOR RELEASE OF BUILDING PERMIT Form updated & effective 9/25/2009 Green Sheet approvals are forwarded to the Building & Safety Department directly by Public Works. Please DO NOT submit the Green Sheet (Public Works Clearance) Packet to the Public Works Department until ALL requirements listed below are complete. Incomplete applications or applications which cannot be processed will be returned to applicant. Date: 11 / 06 / 15 Developer: Sunrose Corporation Tract No.: 29894-4 Tract Name: The Hideaway Lot No. (s):42 Address(s): 53459 Via Dona Phone Number:7( 60 ) 773-6633 The following are the requirements for Public Works Clearance to authorize issuance of a building permit from the Building & Safety Department: ❖ CUSTOM HOMES: PROVIDE ITEMS #2, #3, #4, #5 & #7 BELOW ❖ TRACT HOMES: PROVIDE ITEMS #1, #2, #3 & #5 BELOW ❖ COMMERCIAL BUILDINGSIOTHER: PROVIDE ITEMS #1 #2 #3 ;l#5 & #7 BELOW ❖ WALLS, SIGNS, OTHER: PROVIDE ITEM #6 BELOW 1. Attach Pad Elevation Certificates in compliance with the approved design elevation for building pad (maximum allowable deviation of +/- 0.1 foot). Pad Elevation Certificates must be current (within 6 months of current date). If a precise grading plan creates the pad for approval, please withhold green sheet submittal until a'Pad Elevation Certificate can be provided. 2. Attach geotechnical certification of grading plan compliance including compaction reports from a licensed Soils Engineer. Recently rough graded residential developments which have a previously approved geotechnical certification are exempt from this requirement. 3. Attach recorded final map or title information/grant deed showing proposed building locations are legal lots. 4. Complete the attached <1 acre per lot or infill project Fugitive Dust Control project information form, PM10 plan & agreement or provide alternative & valid City approved PM10 plan set reference number or hard copy plan. PM10 plans for commercial &'residential developments (beyond 1 lot) are submitted separately with grading plans & are subject to additional requirements. A current PM10 certification number is required. 5. Attach a copy of the rough or precise grading plan to the Public Works Department showing building location(s) for pad elevation verification. AO flood zone developments will require an approved flood plain development plan. 6. Attach supporting documentation for wall plan, monument sign, grease trap or special facility installations. 7. Complete and sign the attached water quality management plan (WQMP) exemption form, if applicable. PW approved building construction projects require either a WQMP or a completed WQMP exemption form. Approved maps/plans may be viewed at the following link: http://www.la-auinta.o[g/PlanCheck/m search.aspx I have reviewed and confirmed the requirements listed above as presented and find the improvements to be sufficiently complete for construction of the proposed buildings/structures/walls/signs on the subject lot(s). Pursuant to my findings, the above project may be released for building permit issuance. This section completed by City staff, Recommended by: Date: I/ JAl ff Public Works Distribution: ( ) Green Sheet to Building & Safety ( ) Green Sheet to Planning Department Declined for approval for reason(s) as follow(s), please correct and resubmit: T:1Checklists - Forms & ApplicationsWonns & ApplicationslGREEN SHEET cover & PM10 less than 1 Acre Revised 9-25-09.doc City of La Quinta - PM10 Fugitive Dust Control Project Information Construction Phase PM10 Aareement (<1 acre/lot or Infill Proiect) Project Information Project Contractor: Sunrose Corporation Project Phase (check one) Construction Demolition Project Name: Turban Residence Project Tract/Lot Numbers: 29894-4 Project Street Address: 53459 Via Dona Total Acres in Active Construction (<1 acre per Lot): 14,120 11 06 15 11 06 15 Anticipated Start Date: / / Anticipated Completion Date: / / PM10 Contact Information Please note: Dust control is required 24 hours a day, 7 days a week, regardless of construction status. Person listed below is responsible for dust control during business and non -business hours. Name: Jenny McIntire Title: Administration Company Name: Sunrose Corporation Mailing Address: 40101 Monterey Ave, #131-214 City, State, ZIP Code: Rancho Mirage, CA 92270 Primary Phone #: 760-773-6633 Fax #: 760-773-6634 24 Hour Emergency Phone#: 760-773-6633 Cell Phone #: 760-702-0119 Email Address: sunrose.sedona@gmail.com PM10 Certificate #: CV1402-000405-449 The above stated property owner (or authorized representative): ❖ Shall act as his/her acknowledgement of dust control requirements and their enforceability, pursuant to SCAQMD Rules 403, 403.1, 401, 402, 201, 203 and PERP; ❖ Shall constitute an Agreement to comply with all project conditions as identified in the approved dust control plan. ❖ Acknowledges that dust control is required twenty-four (24) hours a day, seven (7) days a week, throughout the period of project performance, regardless of project size or status; ❖ Shall ensure that each and every contractor, subcontractor and all other persons associated with the project shall be in continuous compliance with all requirements of the approved dust control plan; ❖ Shall take all necessary precautions to minimize dust, even if additional measures beyond those listed in the dust control plan are necessary; ❖ Shall authorize representatives of City/County to enter the property for inspection and/or abatement purposes; ❖ Shall hold harmless the City/County and its representatives from liability for any actions related to this dust control plan or any City/CoL(nty initiated abatement activities. Signatur of Prop y Owner or Authorized Representative Date T:\Checklists - Forms & Applications\Fonns & Applications\GREEN SHEET cover & PM10 less then 1 Acre Revised 9-25-09.doc 3. City of La Quinta - PM10 Fugitive Dust Control Plan (<1 acre per Lot or Infill Project) This Fugitive Dust Control Plan shall take into account applicable SCAQMD Regulations Rule 403, 403.1, 401, 402, 201, 203 and Portable Equipment Registration Program (PERP). ❖ WATERING: Continuous watering is required to prevent dust and must occur a minimum of four (4) times daily Water shall be applied from an adequate sized metered water source to dry soils to prevent: ■ Visible dust emissions >20% opacity ■ Visible dust emissions that travel >100 feet from the source (within site) ■ Visible dust emissions that cross any property line ❖ EDUCATION: The responsible dust control Individual and key personnel shall attend SCAQMD PM10 class and obtain PM10 certificate number prior to construction activity (training information may be obtained by contacting SCAQMD at (909) 396-2183). ❖ CONSTRUCTION & DEMOLITION ACTIVITIES: A copy of this approved Fugitive Dust Plan must be kept on site. At least one short-term stabilization method must be used during off hours. At least one long-term stabilization measure must be used within ten (10) days of ceasing activity. ❖ WEATHER MONITORING: Wind predictions shall be monitored. ❖ SIGNAGE: Approved signs shall be installed at a highly visible location. Please refer to the Coachella Valley Fugitive Dust Control Plan Handbook for Construction Signage Guidelines. ❖ TRAFFIC: Construction traffic shall not be allowed on the pad, unless absolutely necessary. If vehicles operate on pad, pad shall be kept firm and moist through hose watering and sprinklers; and a maximum traffic speed of 15mph will be enforced. Fugitive Dust shall be prevented by fencing off site to prevent unauthorized traffic on pad. ❖ PARKING: Parking is not allowed on pad. All vehicles must park on street at designated areas only. ❖ TRACK OUT: Provide 24 hour street cleaning and track out system as approved by City Public Works inspectors. No dirt on public or private roads. Track out shall be cleaned up within one (1) hour of incident and at the conclusion of each workday. ❖ DIRT PILES: Dirt piles shall be limited to 50 cubic yards and built per California Building Code grading requirements. Piles shall be kept moist or covered with tarp material. Larger dirt piles will require stockpile or grading permit. ❖ FENCING: Provide PM10 fencing at perimeter of public roads and where applicable. Wood slat fencing can be installed at rear of property and return 20 feet on either side if HOA restrictions apply. Block walls can replace PM10 fencing during the construction phase. ❖ EQUIPMENT: Extra hoses and sprinklers shall be maintained on site. ❖ EXCAVATION MEASURES: All areas to be excavated or graded shall be pre -watered. Water shall also be applied during excavation or grading operations. ❖ DUMP TRUCKS: Open top dump trucks shall be wet down, moist and covered with a tarp prior to leaving site. ❖ INACTIVE SITE: Within 10 days of ceasing of activities, re -vegetate or permanently stabilize as required. ❖ RECORD KEEPING: Fugitive Dust Control Plan records (i.e. self inspection records, records of use of chemical suppressants, etc.) shall be maintained for 3 years by the Property Owner (or Authorized Representative). Property Owner shall notify the City and SCAQMD within 10 days of completion of project. TAChecklists - Fonns & Applications\Fonns & Applications\GREEN SHEET cover & PM10 less than 1 Acre Revised 9-25-09.doc RECORDING REQUESTED BY Daniel E. Olivier Nethery/Mueller/Olivier LLP AND WHEN RECORDED MAIL DOCUMENT AND NOVTAX STATEMENT TO: Irl NAME Daniel E. Olivier Nethery/Mueller/Olivier LLP CITY OF COMMUNITY STREET 41-750 Rancho Las Palmas Drive ADDRESS Bldg H CITY, STATE & Rancho Mirage, California ZIP CODE 92270 TITLE ORDER N0. N/A ESCROW NO. N/A GRANT DEED 11:0 APN: 777-420-025-8 0 2015 ®UINTA DOC # 2015-0146974 04/13/2015 11:55A Fee:18.00 Page 1 of 2 Recorded in Official Records County of Riverside Peter Aldana Assessor, County Clerk & Recorder 1111111111111111111111111111 IN 1 S -F RTU PAGE SIZE DA MISC LONG RFD COPY 2 l M A L 465 426 CO NCORSMF NCHG G,EXAM V T: CTY UNI SPACE ABOVE THIS LINE FOR RECORDER'S USE ONLY /g1:20 The undersigned grantor(s) declare(s) DOCUMENTARY TRANSFER TAX $ n 815 0 computed on full value of property conveyed, or computed on full value less liens and encumbrances remaining at time of sale. 0 Unincorporated Area City of La Quinta FOR VALUABLE CONSIDERATION, receipt of which is hereby acknowledged, I (We) Gary Sorensen and Tamara Sorensen, Husband and Wife (NAME OF GRANTOR(S)) hereby remise, release and grant to Scott D. Turban and Dana D. Turban Husband and Wife (NAME OF GRANTEE(S)) the following described real property in the City of La Quinta County of Riverside State of California (Insert Legal Description) PARCEL 1: Lot 42 of Tract No. 29894-4, in the City of La Quinta, County of Riverside, State of California, as shown by map on file in Book 351, Pages 49 to 57, -inclusive, of maps, in the Office of the County Recorder of Rivprside County, California. Parcel 2: Non-exclusive Easements for Access, INgress, Egress, Doge, Maintenanw,.Ieepairs and for other purpose, All as Described in Declaration DATED: April 2015 G Name A notary public or other officer completing this certificate 00 verifies only the identity of the individual who signed the ame document to which this certificate is attached, and not the truthfulness, accuracy, or validity of that document. STATE OF CALIFORNIA COUNTY OF RIVERSIDE ) P On 419 (5 before me, a.i'Y) v` Q �i � /let��'�ar�J 2.61'1c. personally appeared CD(here insert name and title of the officer) I lD �` 6C 2.115 e -o oA d, (aa" \ «-f'q S CCen S ej} - who provedlo me on the basis of satisfactory evidence to be the person(s) whose name(s) is/are subscribed to the within instrument and acknowledged to me that he/she/they executed the same in his/her/their authorized capacity(ies), and that by his/her/their signature(s) on the instrument the person(s), or the entity upon behalf -of which the person(s) acted, executed the instrument. (certify under PENALTY OF PERJURY under the laws of the State of California that the foregoing paragraph is true and correct. WITNESS my and and official seal. Signature MAIL TAX STATEMENT AS DIRECTED ABOVE 4htQEV. Ft6t.0 Commission #► 2088483 (SEAL) a Notary Public - California Z ' Riverside Coultty My comm. Ex ires Nov 1, 2018 ,��'. _ �� �:;�„'' �.?i. ,��:,� , _ ,,y��_ � � ,� i �_�rr;-�a.i PETER ALDANA Recorder P.O. Box 751 COUNTY OF RIVERSIDE Riverside, CA 92502-0751 ASSESSOR -COUNTY CLERK -RECORDER (951)486-7000 www. rivers i deacr. co m CERTIFICATION Pursuant to the provisions of Government Code 27361.7, I certify under the penalty of perjury that the following is a true copy of illegible wording found in the attached document: (Print or type the page number(s) and wording belowl: 1 t j Date: '/- / -3 /J'— Signature: Print Name: ACR 601 (Rev. 09/2005) Available in Alternate Formats 2015-0146974 04/13/2015 11 : 55R HTK Structural Engineers Turban / Hideaway 42D Plan Check Corrections November 19, 2015 Issue Number: Section I —Structural 1. All structural plans and calculations have been stamped and signed by a licensed engineer. Additional Corrections 1. All structural plans and calculations have been stamped and signed by a licensed engineer. 2. Soil reported provided (by others) and referenced on structural plans on sheet SP1 under Foundation Notes.. 3. Specified type V concrete, 4500 PSI for all concrete on structural plans. 4. Provided truss calculation package (by others). 5. Hardscape by others 6. Provided foundation for isokern fireplace analysis. Anchorage and fireplace by others. Design uplift minimal & provided minimum anchorage required. 7. Revised to wind exposure C; Corrected all shearwalls where wind governs (current shearwalls still adequate). w 8. Specified dimensions of all footings at Simpson SB walls C,IT*Y OF LFAF, Q PINTA 9. Added and/or corrected all redlines on structural plans. BUILDING & SAFETy DEPT, APPROVE® FOR CONSTR CTION DATE f'2 Z (S BY \ r r 2015 �rgrFOF Cq 1F3R VIN Of p .LOPv%l co MMUMT1 H 0 GENERAL NOTES 1. ANY GRADING PERFORMED TO ESTABLISH OR RE-ESTABLISH THE BUILDING PAD ELEVATION SHALL BE PERFORMED IN ACCORDANCE WITH THE APPROVED ROUGH GRADING PLAN AND A SEPARATE PERMIT ISSUED BY THE CITY OF LA QUINTA PUBLIC WORKS DEPARTMENT. 2. THE CONTRACTOR IS AUTHORIZED TO PROCEED WITH FINE GRADING ACTIVITY RELATED TO ELEVATIONS SHOWN ON THIS PLAN, ON ANY SPECIFIC LOT ON THE PLAN, ONLY IF, A VALID BUILDING PERMIT HAS BEEN ISSUED BY THE LA QUINTA BUILDING AND SAFETY DEPARTMENT FOR CONSTRUCTION OF THE PRIMARY STRUCTURE ON THAT PARTICULAR LOT. 3. A SEPARATE PERMIT SHALL BE OBTAINED FROM THE LA QUINTA BUILDING AND SAFETY DEPARTMENT FOR ANY BLOCK WALLS SHOWN ON THIS PLAN. 4. THIS PLAN IS FOR ON -LOT CONSTRUCTION ONLY. ALL OFF -LOT CONSTRUCTION ACTIVITY SUCH AS DRIVEWAY APPROACHES OR OTHER IMPROVEMENTS IN THE STREET RIGHT OF WAY, SHALL BE PERFORMED BY SEPARATE PLANS AND PERMIT ISSUED BY THE LA QUINTA PUBLIC WORKS DEPARTMENT. 5. THE CONTRACTOR IS RESPONSIBLE FOR OBTAINING ALL REQUIRED PERMITS. 6. THE CONTRACTOR, AND ITS SUBCONTRACTORS, ARE RESPONSIBLE FOR ENSURING THE DRAINAGE CONCEPT SHOWN ON THIS PLAN IS NOT COMPROMISED BY LANDSCAPING FEATURES OR OTHER APPURTENANCES NOT SHOWN ON THIS PLAN. 7. AFTER CLEARING PLANT GROWTH AND OTHER DELETERIOUS MATERIAL FROM THE BUILDING PAD, THE GROUND SURFACE WITHIN THE BUILDING ENVELOPE SHALL BE SCARIFIED TO A MINIMUM OF 6" AND THEN COMPACTED TO NINETY PERCENT (90X) RELATIVE DENSITY PER A.S.T.M. SPECIFICATIONS. 8. THE CONTRACTOR SHALL NOT DISTURB EXISTING SURVEY MONUMENTS OR BENCH MARKS NOTED ON THE PLANS, OR FOUND DURING CONSTRUCTION. REMOVAL AND REPLACEMENT SHALL BE DONE BY A REGISTERED CIVIL ENGINEER WITH AN R.C.E. NUMBER BELOW 33,966, OR A LICENSED LAND SURVEYOR ONLY. 9. ALL STREETS, PUBLIC OR PRIVATE, SHALL BE CLEANED DAILY OF DIRT, MUD, AND DEBRIS DEPOSITS RESULTING FROM ANY ACTIVITY RELATED TO CONSTRUCTION OCCURING ON THE LOTS SHOWN ON THIS PLAN. CLEANING SHALL BE PERFORMED TO THE SATISFACTION OF THE BUILDING OFFICIAL OR CITY ENGINEER. 10. THE CONTRACTOR SHALL PROVIDE WIND EROSION AND DUST CONTROL MEASURE AS REQUIRED BY THE FUGITIVE DUST CONTROL PLAN APPROVED FOR THIS PROJECT. 11. CONSTRUCTION OPERATIONS AND MAINTENANCE OF EQUIPMENT WITHIN ONE HALF MILE OF HUMAN OCCUPANCY SHALL BE PERFORMED ONLY DURING THE TIME PERIODS AS FOLLOWS: OCTOBER 1ST TO APRIL 30TH: MONDAY -FRIDAY 7:00 AM TO 5:30 PM SATURDAY 8:00 AM TO 5-00 PM MAY 1ST TO SEPTEMBER 30TH: MONDAY -FRIDAY 6:00 AM TO 7:00 PM PAVERS PEF SATURDAY 8:00 AM TO 5.00 PM WORK SHALL BE PROHIBITED ANY TIME ON SUNDAY OR FEDERAL HOLIDAY. 12. MAXIMUM CUT AND FILL SLOPES = 2:1. 13. MINIMUM BUILDING PAD DRAINAGE SHALL BE 2%. DRAINAGE SWALES SHALL BE A MINIMUM OF 0.3' DEEP AND BE CONSTRUCTED A MINIMUM OF 2' FROM THE TOP OF CUT OR FILL SLOPES. MINIMUM SLOPE OF SWALES SHALL BE 0.50%. LEGEND FINISHED SURFACE . . . . . . . . . . . . . . . FS HIGH POINT . . . . . . . . . . . . . . . . . . . HP LOW POINT . . . . . . . . . . . . . . . . . . . LP GRADE BREAK . . . . . . . . . . . . . . . . . . GB INVERT . . . . . . . . . . . . . . . . . . . INV TOP OF WALL . . . . . . . . . . . . . . . . . TW PAD ELEVATION . . . . . . . . . . . . . . . . . PE FINISHED FLOOR ELEVATION. . . . . . . . . . . FF FLOWLINE . . . . . . . . . . . . . . . . . . . . FL PROPERTY LINE . . . . . . . . . . . . . . . . PL - CLEAN OUT . . . . . . . . . . . . . . . . . . • C.O. TOP OF CURB . . . . . . . . . . . . . . . . . TC TOP OF FOOTING . . . . . . . . . . . . . . . . TF FINISHED GRADE . . . . . . . . . . . . . . . . • FG TOP OF GRATE . . . . . . . . . . . . . . . . . . TG END OF PAVEMENT . . . . . . . . . . . . . . . . EP (XXX.XX). . . . . . . . . . . . . . . . . . . . . . EXIST. ELEV. RIGHT OF WAY R/W PLANTER AREA . . . . . . . . . . . . . . . . . . P.A. WATER METER . . . . . . . . . . . . . . . . . . WM SEWER LATERAL . . . . . . . . . . . . . . . . . SL PUBLIC UTILITY EASEMENT. . . . . . . . . . . . ------ SETBACK LINE . . . . . . . . . . . . . . . . . _ _ - FLOW GRADE . . . . . . . . . . . . . . . . . . . TOP OF SLOPE . . . . . . . . . . . . . . . . . . TOE OF SLOPE . . . . . . . . . . . . . . . . . . . EXISTING SEWER LINE . . . . . . . . . . . . . . _S EXISTING WATER LINE . . . . . . . . . . . . . . Vy BLOCK WALL. 8' NDS CAP WITH 6' CLEANOUT LNLET INLET (0Tlp ON z 0 COMPACT BACKFILL TO 90% MIN. WfTH TOP 12' COMPACTED TO 95% - 4' CONCRETE SLAB (POURED IN PLACE) EXTEND 6' INTO UNDISTURBED SOIL (CLASS 520-C-2500 CONCRETE) TLET -Fl-OW-- OU PRECAST PERFORATED CONCRETE RING '3/8' TO 3/4' WASHED ROCK A NON -WOVEN RLTER FABRIC PER SEC 88-103 CAL. STD. SPEC. SHALL BE USED BETWEEN THE WASHED ROCK AND UNDISTURBED SOIL _318" TO 3/4" WASHED ROCK ON UNDISTURBED SOIL A MINIMUM 12" THICK NOTE: ALL JOINTS ABOVE THE LEACHING AREA SHALL BE MORTAR SEALED INSIDE AND OUT. DRYWELL DETAIL NOT TO SCALE IN THE CITY OF LA QUINTA, COUNTY OF RIVERSIDE, STATE OF CALIFORNIA PRECISE GRADING PLAN THE HIDEAWAY LOT 42[D TRACT 29894-4 M.B. 351/49-57 PORTION OF SECTION 9, T.6S., R.7E., SBB&M CONSTRUCTION NOTES 1U INSTALL YARD DRAIN, NDS #50, 6" DIA. GREEN GRATE OR EQUAL. 2O INSTALL 6" PVC PIPE, (SDR -35). S=1% UNLESS OTHERWISE NOTED ON PLAN. 0 INSTALL 6"05' BEND (PVC -SDR -35). ® CONSTRUCT WALL PER SEPARATE PLAN AND PERMIT. O INSTALL 6"x6" TEE (PVC -SDR -35). © CONSTRUCT 6" MIN. THICKNESS PAVER DRIVEWAY PER ARCHITECT PLAN. INSTALL BUBBLER BOX WITH GRATE TOP, NYOPLAST 12" DRAIN BASIN PER DETAIL HEREON. ® CONSTRUCT 10' DEEP DRYWELL PER DETAIL HEREON. gO CONSTRUCT YARD DRAIN, NDS #16S, 3' DIA. GRATE OR EQUAL. 10 INSTALL YARD DRAIN, NDS #3, 4' SQ. SATIN BRASS GRATE OR EQUAL 12 INSTALL 7/16' BRICKSLOT (GALVANIZED STEEL), PART #98999 PER DETAIL HEREON, OR EQUAL 13 CONSTRUCT CLEAN OUT, PER DETAIL ON HEREON SET FLUSH WITH FINISH SURFACE 14 INSTALL 6' PVC C-900 W/BELL & GASKET JOINT, PER ASTM F477 & ASTM 3139, SLOPE AT 1% UNLESS OTHERWISE NOTED ON PLAM (MIN. COVER 36'x. ARCHITECT PLAN,, / PROVIDE 3/8" GAP BUBB__.. OVER 6" COMPACTED 1" ROCK ENC R FABRIC APPROVED FOR PERMITTING BURT HANADA DATE BUILDING AND SAFETY DIRECT❑R CITY OF LA QUINTA PLANNING AND ZONING COMPLIANCE LES JOHNSON DATE COMMUNITY DEVELOPMENT DIRECT❑R CITY OF LA QUINTA i N VIUINI I Y MHr N.T.S. BENCHMARK - LOCAL BENCHMARK TBM TOP OF CURB AT THE INTERSECTION OF THE PROLONGATION OF THE NORTHERLY PROPERTY LINE OF LOT 42 WITH THE WESTERLY CURB OF VIA DONA, PER CITY OF LA QUINTA GRADING PLAN, PLAN NUMBER 040504-13 ELEV. = 1001.72 DATUM = NGVD29 +1000.00' BASIS OF BEARINGS THE BASIS OF BEARINGS FOR THIS MAP IS THE NORTHERLY PROPERTY LINE OF LOT 42, AS SHOWN BY A MAP ON FILE IN BOOK 351, PAGES 49-57 INCLUSIVE OF MAPS, OFFICIAL RECORDS, COUNTY OF RIVERSIDE, STATE OF CALIFORNIA BEING: NORTH 75006'49"EAST PREPARED UNDER THE SUPERVISION OF: QROFESS/ON PR Syq ql ESFANDIAR SHAHANDEH DATE: \ ;���;�47 49����z S S I RCE N0. 47834 � �, No. s3 =� rGINEERING APPROVED BY: RCE NO. EXP. DATE DATE: qT CIV1�- \OF CNO LEGAL DESCRIPTION LOT 42 OF AMENDED TRACT 29894-4, AS SHOWN IN MAP BOOK 351, PAGES 49-57, RECORDS OF RIVERSIDE COUNTY, STATE OF CALIFORNIA. NOTE: DRIVEWAY APPROACH REQUIRES A SEPARATE PERMIT AND INSPECTION FROM CITY OF LA QUINTA PUBLIC WORKS DEPARTMENT LOT COVERAGE: TOTAL LOT AREA = t 14,120 SF TOTAL BUILDING AREA (COVERED PATIO AND GARAGE INCLUDED) = f 6,810 SF BUILDING AREA/LOT AREA = 48.2 % APN: 777-420-025 53-459 VIA DONA TURBAN RESIDENCE . PRECISE GRADING PLAN 77-540 SPRINGFIELD LANE, SUITE c- THE HIDE WAY LOT 4 2 PALM DESERT, CA 92211 (760) 772-8400 OFFICE (760) 772-8421 FAX TR 29894-4 MB 351/49-57 igineering - planning - surveying PORTION OF SECTION 9, T.6S., R.7E., SBM CITY OF LA QUINTA 9/9/15 DESIGN: DRAFT: BEDROOM 21401 ESSI CHECK: GA,'3AGE .. GB AUG. 2015 1 . ! I 34 TC 7 BATH 2 o C.1~D WY SERVICE 1003.26 100"'U'W 100 -- C1 003.08 ND '' 8100 I; I I J-1� 2 2 7 M PA Q T.. CU 2 PA .Ja ' TELECOM ❑ - G STRAMP ` ,. .; �., 2 PA �Fl .AF:l PA. 2 � ELE I IN CU'B II•`I (N75-06'49 E 167.45') I 1 1008.80TW 4 1 1008.80TW 4 N82*41'S1.E 1008.80TIMI`' �' �ZON 10 1.19 TC I I I I I 10 1.73 FL I 1002.8FG 1001.80TF 1002.8FG 1001.80TF 1002.8FG 1001.80TF VERI II I II I LOT 41D ;; I - PE (1002.3) I VACANT L I III g i o i I I it BENCHMARK - LOCAL BENCHMARK TBM TOP OF CURB AT THE INTERSECTION OF THE PROLONGATION OF THE NORTHERLY PROPERTY LINE OF LOT 42 WITH THE WESTERLY CURB OF VIA DONA, PER CITY OF LA QUINTA GRADING PLAN, PLAN NUMBER 040504-13 ELEV. = 1001.72 DATUM = NGVD29 +1000.00' BASIS OF BEARINGS THE BASIS OF BEARINGS FOR THIS MAP IS THE NORTHERLY PROPERTY LINE OF LOT 42, AS SHOWN BY A MAP ON FILE IN BOOK 351, PAGES 49-57 INCLUSIVE OF MAPS, OFFICIAL RECORDS, COUNTY OF RIVERSIDE, STATE OF CALIFORNIA BEING: NORTH 75006'49"EAST PREPARED UNDER THE SUPERVISION OF: QROFESS/ON PR Syq ql ESFANDIAR SHAHANDEH DATE: \ ;���;�47 49����z S S I RCE N0. 47834 � �, No. s3 =� rGINEERING APPROVED BY: RCE NO. EXP. DATE DATE: qT CIV1�- \OF CNO LEGAL DESCRIPTION LOT 42 OF AMENDED TRACT 29894-4, AS SHOWN IN MAP BOOK 351, PAGES 49-57, RECORDS OF RIVERSIDE COUNTY, STATE OF CALIFORNIA. NOTE: DRIVEWAY APPROACH REQUIRES A SEPARATE PERMIT AND INSPECTION FROM CITY OF LA QUINTA PUBLIC WORKS DEPARTMENT LOT COVERAGE: TOTAL LOT AREA = t 14,120 SF TOTAL BUILDING AREA (COVERED PATIO AND GARAGE INCLUDED) = f 6,810 SF BUILDING AREA/LOT AREA = 48.2 % APN: 777-420-025 53-459 VIA DONA TURBAN RESIDENCE . PRECISE GRADING PLAN 77-540 SPRINGFIELD LANE, SUITE c- THE HIDE WAY LOT 4 2 PALM DESERT, CA 92211 (760) 772-8400 OFFICE (760) 772-8421 FAX TR 29894-4 MB 351/49-57 igineering - planning - surveying PORTION OF SECTION 9, T.6S., R.7E., SBM CITY OF LA QUINTA 9/9/15 DESIGN: DRAFT: ESSI ESSI CHECK: DATE: AMG AUG. 2015 DWG No. PG113001 G-1