BRES2015-041278-495 CALLE TAMPICO
LA QUINTA, CALIFORNIA 92253
Application Number:
Property Address:
APN:
Application Description:
Property Zoning:
Application Valuation:
Applicant:
SUNROSE CORPORATION
72-850 SOM ERA ROAD
PALM DESERT, CA 92260
T4'!t 4 4 Qu1#&:
COMMUNITY DEVELOPMENT DEPARTMENT
BUILDING PERMIT
BRES2015-0412
80210 VIA CAPRI
777100070
HIDEAWAY CLUB / NEW SFD / SUNROSE RESIDENCE
$609,604.20
-LICENSED CONTRACTOR'S DECLARATION
I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter
9 (commencing with Section 7000) of Division 3 of the Business and Professions Code,
and my License is in full force and effect.
License Class: B License No.: 533670
Date: el ContrIto
OWN ER -BUILDER DECLARATION
I hereby affirm under penalty of perjury that I am exempt from the Contractor's State
License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any
city or county that requires a permit to construct,,alter, improve, demolish, or repair
any structure, prior to its issuance, also requires the applicant for the permit to file a
signed statement that he or she is licensed pursuant to the provisions of the
Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division
3 of the Business and Professions Code) or that he or she is exempt therefrom and the
basis for the alleged exemption. Any violation of Section 7031.5 by'any applicant for a
permit subjects the applicant to a civil penalty of not more than five hundred dollars
($500).: '
(_) I, as owner of the property, or my employees with wages as their sole
compensation; will do the work, and the structure is not intended or offered for sale.
(Sec. 7044, Business and Professions Code: The Contractors' State License Law does not
apply to an owner of property who builds or improves thereon, and who does the work
himself or herself through his or her own employees, provided that the improvements
are not intended or offered for sale. If, however, the building or improvement is sold
within one year of completion, the owner -builder will have the burden of proving that
he or she did not build or improve for the purpose of sale.).
(1 I, as owner of the property, am exclusively contracting with licensed contractors
to construct the project. (Sec. 7044, Business and Professions Code: The Contractors'
State License Law does not apply to an owner of property who builds or improves
thereon, and who contracts for the projects with a contractor(s) licensed pursuant to
the Contractors' State License Law.).
(_) I am exempt under Sec. . B.&P.C. for this reason
Date:
Owner:
CONSTRUCTION LENDING AGENCY
I hereby affirm under penalty of perjury that there is a construction lending agency for
the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). -
Lender's Name:
Lender's Address:
48
_ VOICE (760) 777-7125
FAX (760)777-7011
INSPECTIONS (760) 777-7153
Date: 1/14/2016
Owner:
MOUNTAIN WEST INVESTMENT1S,-
40101 MONTEREY AVE STE B1T 4 �1
RANCHO MIRAGE, CA 92270
Contractor: z tv
SUNROSE'CORPORATION o
72-850 SOMERA ROAD rn
PALM DESERT, CA 92260
(760)773-6633
Llc. No.: 533670
WORKER'S COMPENSATION DECLARATION
I hereby affirm under penalty of perjury one of the following declarations:
I have and will maintain a certificate of consent to self -insure for workers'
compensation, as provided for by Section 3700 of the Labor Code, for the performance
of the work for which this permit is issued.
I have and will maintain workers' compensation insurance, as required by
Section 3700 of the Labor Code, for the performance of the work for which this permit
is issued. My workers' compensation insurance carrier and policy number are:
Carrier: _ Policy Number: _
I certify that in the performance of the work for which this permit is issued, I
shall not employ any person in any manner so as to become subject to the workers'
compensation laws of California, and agree that, if I should become subject to the
workers' compensation provisions of Section 3700 of the Labor Code, I shall forthwith
comply with those provisions.
Date: / Appli /'
WARNING: FAILURE TO SECURE WORKER COMPENSATI N COVERAGE IS UNLAWFUL,
AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO
ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF
COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE;
INTEREST, AND ATTORNEY'S FEES.
APPLICANT ACKNOWLEDGEMENT
IMPORTANT: Application is hereby made to the Building Official for a permit subject to
the conditions and restrictions set forth on this application.
1. Each person upon whose behalf this application is made, each person at whose
request and for whose benefit work is performed under or pursuant to any permit
issued as a result of this application , the owner, and the applicant, each agrees to, and
shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents, and
employees for any act or omission related to the work being performed under or
following issuance of this permit.
2. Any permit issued as a result of this application becomes null and void if work is
not commenced within 180 days from date of issuance of such permit, or cessation of
work for 180 days will subject permit to cancellation.
I certify that I have read this application and state that the above information is correct.
I agree to comply with all city and county ordinances and state laws relating to building
construction, and hereby authorize representatives of this city to enter upon the
above-mentioned property for inspection purposes.
Date: / �3gnature (Applicant or gent
DESCRIPTION
FINANCIAL INFORMATION
ACCOUNT QTY
AMOUNT
PAID
PAID DATE
ART IN PUBLIC PLACES - RESIDENTIAL
270-0000-43201 0
$996.42
$0.00
PAID BY
METHOD RECEIPT #
CHECK #
CLTD BY
Total Paid for ART IN PUBLIC PLACES - AIPP: $996.42 $0.00
DESCRIPTION
ACCOUNT
QTY
AMOUNT
PAID
PAID DATE
HOURLY PLAN CHECK - YES
101-0000-42600
5
$350.00
$0.00
PAID BY
METHOD
RECEIPT: #
CHECK #
CLTD BY
Total Paid for BLDG CITY STAFF - PER HOUR: $350.00 $0.00
DESCRIPTION
ACCOUNT
QTY
AMOUNT
PAID
PAID DATE
BSAS SB1473 FEE
101-0000-20306
0
$24.00
-$0.00
PAID BY
METHOD
RECEIPT # -
CHECK #
CLTD BY
Total Paid for BUILDING STANDARDS ADMINISTRATION BSA: $24.00 $0.00
DESCRIPTION
ACCOUNT
QTY
AMOUNT
PAID
PAID DATE
DIF - CIVIC CENTER
252-0000-43200
0
$942.00
$0.00
PAID BY`
METHOD
RECEIPT #
CHECK #
CLTD BY
DESCRIPTION
'ACCOUNT
QTY
' AMOUNT
PAID
PAID DATE
DIF - COMMUNITY CENTERS
254-0000-43200
0
$129.00
$0.00
PAID BY
METHOD
RECEIPT #
CHECK #
CLTD BY
DESCRIPTION
ACCOUNT
QTY
AMOUNT
PAID
PAID DATE
DIF - FIRE PROTECTION
257-0000-43200
0
$433.00
$0.00
PAID BY
METHOD
RECEIPT #
CHECK #
CLTD BY.
DESCRIPTION
ACCOUNT
QTY
AMOUNT
PAID
PAID DATE
DIF - LIBRARIES
253-0000-43200
0
$344.00
$0.00
PAID BY
METHOD
RECEIPT #
CHECK #
CLTD BY
DESCRIPTION
ACCOUNT
QTY
AMOUNT
PAID
PAID DATE
DIF - PARK MAINTENANCE
256-0000-43200
0
$40.00
$0.00
PAID BY
METHOD
RECEIPT #
CHECK #
CLTD BY
DESCRIPTION
ACCOUNT,
QTY
AMOUNT
PAID
PAID DATE
DIF - PARKS/REC
251-0000-43200
0
$2,048.00
$0.00
PAID BY
METHOD
RECEIPT #
CHECK #
CLTD BY
DESCRIPTION
ACCOUNT
QTY
AMOUNT
PAID
PAID DATE
DIF -STREET MAINTENANCE
255-0000-43200
0...:
;, •, $116.00
$0.00, .
* ..,` t' Xg-. .
z x, PAID„BY ��.r.r ss,��
Z` -PAI
em ., ua
METHOD
IBM
h, ".,: i.4. ;: r{';s
r."a RECEIPT #
s -` ' f?5,'.as,=.6 >s a''
0% `CHECK#� �`.CLTD+BYE
r
_
.. y
�m
r
Y.,k,', 5e:_w.: k!r, akE .ara �S f'e�d ?!,^� _
y
Ya AAY :&'S".v n.. �"''�'Y1i
J`u.:%'ke";
:� f & -) C ✓:"e< : r, a: �jt.: �,'�-5�{ {, � ia{ x "F. �
_
DESCRIPTIONx,
'f ja'kAf�'"s 2xi�X�+' `•-�„n _..5.1
ACCOUNT
�St:"i,4 �wl��
QTY
'`�*�kT�.�i%i �"7":'�' '•iii"kr&�y ��,u � �
AMOUNT
•T�:�; Yay �-h.-.: ":�{SG�s3 � .43'�Y'��'ti �
PAID
� F .i'i ,'�,'. �aE.�s&`ti'.
PAIDDATE
�_
'��'?r
�.d•^.�,E€§!i•{R'FiP.P, '�Z '.v$NR4^:.
b fl>°
,�,< ',',A:;.,e
DIF - TRANSPORTATION
250=000043200
.0.,
$2,842.00
o `?.`Y�
) i:Taa: r£ �(,kLr” 's
�.`a�".•`l��a'4'SYy'�•e: xa'�Y'e: A'.�W`�"${" d� ?„r�'a..�`$
T
;,6 YY`�.:''.'{ti.'^(.x: 'i
D�,
x''
aL._�a
i.x�ai._`�•f."`'{+ MU .!f: 9T'^
x'S-
�?
�'?p°Y,is T:Y.c�%F•Z,'':fibui'�k".�"rs._.0
xP`
CHECK#
b� .i4.{Pa°�' :` e
r'
"CLT BY
.PAIDrBYt
K? 01
� METH, :� 4� ra
f RECEIPT;#
z x�
Vi
Total Paid for'DlF - SINGLETAMS ILY DWELLING: $6,894.00 $0.00
,G:t. .'}�.% ". $'4'I &
� N A kR 4X'ii..i3r4 {,W.e,•zFiF.. "{'3`Y£'. "lei
�{ACCOUNW,QTY�
f [!'4i4 i'R, Jyf"
xi 1'. pa�jy5'Q:� �•^� Af E'$S'. yy
"Ymmg -n r •'.:'a a {
d ..�",�x„
PAID
., z,.DESCRIPTION_4
AMOUNT«F
PAIDr,
DATE
TEMP POWER SERVICE
101-0000=42403
0
:$24.17.
$0.00
BY,nfa'>;
�flVr
BY
.�METHOq
�LECEIP�011CuL
�v,
2-•y <ry ; � 7 twL.__-. ,� ro, �To." -'4} x`t f'1 - .. � �1:
DESCRIPTION
#',� Jc?4;�"+ u naX�+`�-ez ;��;:F.` ��:.
� ,e>�� �* v.y. '�a"";�.,;x ��t-.> ,,�
AMOUNTjPAID4,X�{
.� �t. ���.,_"y�3.czey�. a":
i _'�.r-�"t�f;_i:*7•"' - �,
PAID DATE
�ACCO,UNT3CZTY
TEMP POWER SERVICE' PC
101-0000-42600
0 $16.92',
ra.::
PAID BY r��F�"°�
'" f 4'S#[".<z:.., a V-"$.
METHOD��
._. r..� ..:�,:,s2'.;t ;.'� >�:'"ivj
RECEIPT #
.x., s4H, -%r'".'2
h.
BYE=
MEMOS
a� ,r. `i.���...�a_xsrY.r��:=n�. �.. r��.z�t3z4
.�... � ��,- - _.�.�_ � �Y.,`�?_:;i�_.
xx�CHECK<#f=�CLT.D
�o..> �x..�:.
x,�-x,,.�:.
Total,Paid for ELECTRICAL: " $41.09. $0:00,
r RIPTIN r„ ;r +
SC O
:.
�� ACCOUflIT'4T1f
t
"" a:�
'
PAID DATE
.'DE
s r
`k< z'.'YP 73...'-, ..
99
*�iAMOUNT a
v.A...�'
PAID€ Y3
"a, 5, `.ti.
d
RESIDENTIAL,"EA ADDITION 1,000SF ' ,,
101-000042403
0
$98.64
_-$0.00.
R a F
1; G -[' }� ti
PAID:BY e�
h s- it- ? 8
-} t
METHOD
YF
RECEIPTS
tT rg£k'-�i4j.. :Z'Y'""'*T - Y'
CHECK'#�x�
% W N ('•'S v
C m BY
Rq
r
x
v,:, ,
g
ih`Gr-.. vk. c.4£ -7y
.....
". ff4.sa' s.xs;�f x�v� w''kecS
ACCOUNT
-�% ..;s; 4k;K,
,w a..-s::rr..,<_.
PAID
PAID t)ATE
rDESCRIPTION� „m
+
g ...""
CZTY
AMOUNT
RESIDENTIAL, EA ADDITION 1,000SF, PC
101-0000-42600
0
$40.64..
. ,• $0.00.
,>, { +�. ` } 34 :R., i �(S t '?v �''• Fivffi �+ �➢`.asx
PAID-BYifM�ETHOD�
662
f Yr y$:F .i'F'f'„u. - h-N.P�.F {4
{ca "Sv i 3,...�.9.e ''+• 'Yi'..
1F. ,.3� {, �.
tClTOBY
0 3F .[ u5bn4,
$RECEIPT>#`�
CHECK#
ri
�.
`at .t: ,�•"," .:
<�
w—, kC,;;
4yv ' e.,t6if�.:i' �}S'k'+%$bn. $P.p, °'k+ L
�1
c :,yk%„ r"',..:.. + `�, "e�' ob i-bt&
PAID'
M ." ':'3' F '� -a'F, y
PAIDDATE=
.ray:, ��ACCOUNTs ?
„TIfAMOUNT
x
RESIDENTIAL,, FIRST 1,0005E
101-0000=42403
0::
:$i45.03'
$0.00 _
{`
PAID°BYE 4 t, I
P'E's'�M1.S��W➢
S Y asap'
�< METHOD
��'RECEIPT #
CHECK
CLTD�BY
h ._a_. � 4
��
. ,
fi._.,4:
t K x Ci 4
a. ?3 'ti 3f
�. �;i.`b'S ��.. ;[�..a; ,•--""
4
�y � -u w.�€`:X.-.'Tii� �*•�"?3�
4x i.%t
,�'w.. vEt.;`"`.'�?,kc;,P �,"
g
PAID DATE<
z,rDESCRtPTIUN�ACCO.UNTk�
my"_.... ,_.
'CZTY�AMOUNT"L:PA
D.:
RESIDENTIAL, FIRST 1,000SF, PC'
101-0000-42600
0 $47.86
$0.00
s h-7 F4 $:., xsd y. #"'4r✓ m'V, ,a+. a'- E
PAID BY��
� %w+:3,. >€:..,r� hQ �isz z'
METHOD E a
�. 3 ".a�n
' a k:.A+sz'K<.r:i3,€d
RECEIPTS#��CHECK#
?
i�CLTD BY
_
. ,
Xx�.:3.'X
. .x.` 2 .�.t$ "f x'%,v".�i. _...< .._3i� �.3.
g
.�..-r fXt4r....?31,
F
Total Paid for ELECTRICAL - NEW CONSTRUCTION: ' .. $332.17 $0.00
X33u
Fiatr�.ft" r
"' vC �i !Px
MOUTe
-P
�� PAD
"PAxIDDATEt
;DESCRIPTIONNT�
RESIDENTIAL PRECISE GRADING =CUSTOM
101=0000=42408 '
0
$36.26 , . '•
$0.00
HOME LOT >7KSF
;S ;p �' }� g%2 ..sem ,' "`i k .: L -
PAID=BY "
�,....E3` ''".c:S ."`�" ...sz�.' ' -2 " °qv
#
-r. Mf?i ,- `a:R'b'°, i.:E, tS'S -: E;
r r:
r m,>RECEIPT#°�4,.k
:;.::. " x.: Y..v, 'c.y..
BY
.',,€.
.e ...... ,: ? :. c4,..,
<METHOD 1.�,
..
tCHECK#�n�CL�TD
rn..r,..r �.. ....
*``%i I'" 'S'
DESCRIPTIONro�,YpACCOUIVT�'r
N. {^ `WY )"f(:.i�ify\yJ':te4
QTY-AMOUNT��
r A n.
PAID
�PAID$DATE
RESIDENTIAL PRECISE GRADING --,CUSTOM
r
'
101-0000-42600
0.
$181.29'
$0.00 `.
HOME LOT >7KSF PC"
,
PAID BY
METHOD
RECEIPT #
CHECK #
CLTD BY
Total Paid for GRADING: $217.55 $0.00
DESCRIPTION
ACCOUNT
QTY
AMOUNT
PAID
PAID DATE
CONDENSER/COMPRESSOR
101-0000-42402
0
$181.30
$0.00
PAID BY
METHOD '
RECEIPT #
CHECK #
CLTD BY
DESCRIPTION
ACCOUNT
QTY
AMOUNT
PAID
PAID DATE
CONDENSER/COMPRESSOR PC
101-0000-42600
0
$120.85
$0.00
PAID BY
METHOD
RECEIPT #
CHECK #
CLTD BY
DESCRIPTION
ACCOUNT
QTY
AMOUNT
PAID
PAID DATE
EXHAUST HOOD
101-0000-42402
0
$12.09
$0.00
PAID BY
METHOD
RECEIPT #
CHECK #
CLTD BY
DESCRIPTION
ACCOUNT
QTY
AMOUNT
PAID
PAID DATE
EXHAUST HOOD PC
101-0000-42600
0
$4.83
$0.00
PAID BY
METHOD
RECEIPT #
CHECK #
CLTD BY
DESCRIPTION
ACCOUNT.
QTY
AMOUNT
PAID
PAID DATE
FURNACE
101-0000-42402
0
$181.30
$0.00
PAID BY
METHOD
RECEIPT #
CHECK #
CLTD BY
DESCRIPTION
ACCOUNT
QTY
AMOUNT
PAID
PAID DATE
FURNACE PC
101-0000-42600
0
$120.85
$0.00
PAID BY
METHOD
RECEIPT #
CHECK #
CLTD BY
DESCRIPTION
ACCOUNT
QTY
AMOUNT
PAID
PAID DATE
VENT FAN
101-0000-42402
0
$108.81
$0.00
PAID BY
METHOD
RECEIPT #
'CHECK #
CLTD BY
DESCRIPTION
ACCOUNT
QTY
AMOUNT
PAID
PAID DATE
VENT FAN PC
101-0000-42600
0
$43.47
$0.00
PAID BY
METHOD
RECEIPT #
CHECK #
CLTD BY
DESCRIPTION
ACCOUNT
QTY
AMOUNT
PAID
PAID DATE
WALL HEATER
101-0000-42402
0
$148.26
$0.00
PAID BY
METHOD
RECEIPT #
CHECK #
CLTD BY
DESCRIPTION
ACCOUNT
QTY
AMOUNT
PAID
PAID DATE
WALL HEATER PC
101-0000-42600
0
$72.54
$0.00
PAID BY
METHOD
RECEIPT #
CHECK #
CLTD BY
DATEry` °
Total Paid for MECHANICAL: , $994.30 $0:00
�.� {k X'YB...i:�..s:_txi�,'"�3',..y4;D,.`q'st.
1DESCRIPT;ION..•�
ACCOUNTr�.
`4s= �.i.�4',q�i:pi=[:Pb+.
'QTY AMOUNT
aM.:i._t
PAID���
PAID.,DATE'=
,. •�.
.6v e..l...-.Y.e3x.. Y4-::'..3'I'S..°'i''x.:9iYSE,"iC.F",d4�+E.{.e'3-rli
r� ,�
??iS2�!?A,A?fY.F«S,T..1k-h
i�S�.,*".,w-ES$iS,wE'fZ,-'{f�f:.^..''�i,dk.tb'�,S'W..d<`.E:.€�!'lei
�E
NEW CONSTRUCTION PERMIT
101-0000-42400-,
0 $805:01
: $0.00
... u"i -$..Y
} Yee •L - Y _, S
PAID BYk
, „T- .��.c";91'3#Y.h'P:x �F.$'x 'z4YyS
3'{'CX� 3� P -:3:? �
ff-
>1 ",•aj. {"(d. aE'rt'H$#.w `Fi
� Ys -f � Y �
RECEIPT #
6l';u.sn. ?"S•if .€H'Y7-)r-F
&J��3% T :3 ➢�.Iv
RECHECK #
Z•T3 a; i
CLTD BY
�rMETHODE
���.,
{
ax •� �.. k?.,,
s�
Total Paid for NEW CONSTRUCTION 'PERMIT: $805.01 $0.00
, a ..:,:-,..:ca" exEtzy .a':,....
DESCRIP.,TIONEr
ACCOUNT����Qr
e"
$
'AINIOUNT
a..xasY
' a.
PAID:GATE
s<,s
t .i •„:s. .,, .:, ..,.....>:. .1 40.2m
,.
,
., -.s-:. �'i.� ,*�!awE.#.vim:,. .i •:�r&- . ,* ,.�a::F
rr..-::? .'+
.
$�:g'i�+. _.sa�A.>b.3!G �E i��..
.PAIDg
ze3'6
NEW CONSTRUCTION PLAN.CHECK
101-0000-42600%
`0
$1,500.00
$1;500.00
10/26/15:
.'r r`'.
°':?i-n:*.,,.s
'�
,z..'..,.r• `s at - mss;
a �
'�., :y=i y'Ft� .
CIiECK#'
•'''q
_PAIDYBY t i � '�
.: METHOD
F. ..,.a*." .,�.-'�.z�
yRECEIRT`#
,$.".�.?.:d; '�"v.. . ,a, 7. " ., :3•
r tt
= .::r,... +a'N max.' a¢W,
a 5'LTD'B�Y�
SUNROSE CORPORATION
CHECK
R10259
2012
MFA
DESCRIPTION*��,_�NACCQfUNTz
:.sri `•aSq..4'`i��`� �' .i�z.>t'' �
a ;F '-,g z
QTYAMOUNT
�:.z.� ,:, �� xi �v� �E :E`���
3,�w., �:"�`ss�.,E,.,
PAID
�PAIODATE,
x _
°._
,
, PP U
,ice �a�� i��.o
NEW CONSTRUCTION PLAN CHECK,`.
101-0000-42600
0
$243.48
$0.00
1 1 4it'iiY �x%el„Aid'�W�1131
'O .P.,..:5,�
METHODRECEIPT
#gCHECK
#g,.,
�CLTD BYSY
Total Paid for NEW CONSTRUCTION PLAN CHECK: : $1,743.48 $1,500:00 .
�' .fes:'.., .➢ v°5. :. nx.Y::.3 %','f+'S'4_er};`uSxY.. C�£35,Xy.'�-•
DESCRIPTION
. tY-+F .: e k``�.
ACCOUNT
ix �Y
y,
�V .Ti.��'i
M T�
t'v:
PAID€
ry"Y .et-v'aE. S•7m.%'.N,
PAIMDATE
s
'BACKFLOW DEVICE
101-0000-42401y+
0
$12.09
,.$0.00
+2:pII�N�XK�v.:¢
r PAID BY f
(�4k _, ��'WPyk 3.`.J.$:,"sT` '.E.f'�3L�4-.Z€'.
-g, . ��
k i
k$F
T]w a-*:.V....,iS..,xg�i' ar"..
RECEIP..T # s
'. '.a:` H .. # Y
� ;
CHECK #C6TDBY
f i.x:. ..
E
x 4z a<r; .,METHOD
.
,� y�
4�
..P...rot;�wr:37�
,
DESCRIPTION, _�
qpg` ACCOUNT x
; QTY
x AMOUNT
PAID. zFPA10OATE
'i.. .f_. ri S`:r.'�.• 7, k:a?.✓a .A,E,.. '.5^a�a?;zc'xa� .=w=w:`?.'
*c9:� iss%..atsagr>tC>.,-fat
:�as.-,rr..,,::°.
��.er'nw":,t�a'
.`*;
BACKFLOW,. DEVICE PC
101-0000-42600 ,;
0
$4.83
$0.00
E: -}''✓res s7-, F,�Y'¢Fxk j a4'-•:.gn.ylE '�' t
�x>:rtY PAIDTBYi�.�EiHOD��
Vis,',+£t;,;�rPnt^`:.ri.'T,'`;, z`"i�4 �'?
z�RECE€IfPT�#
i:'t s`"r:7xea-�
",? x??«..t
CHECK#p
CtTDBYs
• r. .- .J. i. =
f R7 t $ r ; f i. .. •'14. f 1.- .�€?.:} 3Pg :- ; b
DESCRIPTION
's Wit" 2c gY' `.(i .q i uL'X - �`y'y. t4 :..#`es
"v'1 a'?F?l -•` . a2; � ^ p2L. *�'`�"S-' w:
AMOUNT.
'.•.�. y x§ ,.
yPAID
!E
PAID DATE
xr'�ACCOUIVT�"
QTY 9*w
r
BUILDING SEWER' -
101-0000=42401
0 $12.09
$0.00
___`f�hi'aEf'$, 3 ',41��kv.S'
` ! BY< � �
:,rod `"Yc#S �w �§tn 8°€k''k47F K .. �E' 3'
��+ �
i' 4�- �..�
5 IRECEIPT
;. L w..r::..£+A.F a;
- r"t 'r.•Fa' 3'.
¢PAID:
i ,
..
PME7HOD
• ,� -b.3"1 .r€#.,,....:y >v,y T� k,�
#� � QUM
3sEm.`F.ni.0 wAsA? �i":'C+..Y?sP.:Y,
� ��{CHECK4# �� a
.`1 •,7 .Tn a"
-.,f. .Y.n
NOW
., ° •� .. - yy �t } he(. ik e. �'v .�*°Ye �r�l
.i - �y' Ma^e- :�'!z "`"3{ii : G' -! q..E,; -
FACGOUNT
yA:YYEt''� §'3''
%..Y- . [,N-. £'E` ".. 4pm.
;
AMOUNE:PAIDk4NE
: "-.Kt" .-+x, j» ,R•➢!€.:'y.f
".J"-�'t':. e�. -.{.. .:.
rPAIDDATEc
a.. .DESCRIPTION :ttw
r>
. r1&5QTY
j
BUILDING SEWER. PC..
101-0000-42600
0" •
' - $12:09_
.$0:00.
T-
:C,a}c• ¢ f, gm°�°ai°"Ep q.�
PAID BYs�
``,v-t"i ,aa'i:,ii:,%i r E :;z+„ir•''
'��METHOD g
}
`RECEIPT
F;i'se-'."LY:xw+'H.-Em''c�r'..,gq ,E
#CHECK=#
:'. �,a'PE� -%�x+r j?
e7'3..h•>yiv>�:.Ynw;,;Y:xt'x
a.S�€k.".am:.,..;.t
:�`uw_�._:...>;�:>r,...'.°=
4x
"r h -,,� .i E',k SPY'iy
�r�
ACCOLINT��xQTY4
Rx 'iE
L+.. '
b.�
.'e,.
PAIDR�
PAD
,DESCRIPTION
;.E�E._.:.r...€,P �.
-M ,,�.;T.:�
�..c
AMOUNT; E
�.. �x�
,
FIXTURE/TRAP
101=0000-42401,' ' '
0.
•,., $374:79
$0.00
Al x
PAIX �:�' i°an i ;` PF'
D BYs,
4.
':"a`'vE .P.y5"ku` -''.;y _
4 i..
.:€, ., wk.z.�id
p.
CHECK #Pt
�CLTDaBY:
.: <<'�,
_E,:.
�,METIIOD;� .
>.
s�RECEIPT
�.
;�• #n
. _ 3'E >
L,xti° -�+. Y F ,' i.4 ,i4� 'C*1: °t
k Y
ps: •zDE
.' 4'Z Cc`aH.6an`Puf•,s-" `'., t...
:?�a '2"•"X' yH\^�e�'S_` fH: ::.'Y..S'G
QT4YAMOUNT
'L:y 'x..L tom#'+';'' 3:*°v
PAID
moi^- _.... `-•E',o'd*'W
PAID DATE
�1DESCRIPwTION�A00011NT
• �,. r .:.. ., i..%�SMw
FIXTURE/TRAP PC
101,0000 42600
0 $374.79
$0.00 •
F.:.h a,; M1.f_'qgeaaq,�..:='R€a..;i,��
PAID BYE" "��yMETIiOD
�.NN
z�
n�-i`;.•;.:ss._.<-:'iY,€"'s P; :�i; ..r4.e•,
a
CHECK
LT"
RECEIPT #�
BY
DESCRIPTIONSY
,4,x�` 4'..u�'�,^L k-'•"K:i�' � 4
3 � �L�'Ybi•:.f" wT '�i{ � �'K E E
Ja {••. ,�'V'�4i:
PAID
; iRACCOUNT�Qn,rAMOUNTk�4PAID�
IF
T
°
DATEry` °
GAS SYSTEM, 5+ OUTLETS
101-0000-42401
0:. $36.26
$0.00 ,
Y"
.Y 3, E :.Y'.`
u= r° PAID BYf
T E-p✓�
METHOD
4. �7" #
�,eRECEIRT
CHECK #f
\ .;
-r
r
g
�c ..`.4T.n... �F.Ai..: •$i:. -A' FL.':.'�ii ,.. m�..,.
-
'r:..'Y. �..
CLTD BYE
•v& $?�:�.. ?'rie.
,y.�,...�.: a,,,. r: •.;;L,; 'i.yt DESCRIPTION��::,;,�'"`G'�'s
$sB ��:-
.... E. r .:a
ACCO.UNT.,h��
4TY;AMOUNT..xrPAIDz�
�PAIDDATE,r
GAS SYSTEM, 5+ OUTLETS PC
101-0000-42600
0: '
$24.17
$0.00
x- BY � �
',�T,.f�����,
;METHOD 4_ -
t`"�i. 3E.
�
,"�`8' :-n,'es;r•�., m
`.RECEIPT
7: =RAID, : ;
�..•:h.. .,. •�,. ,. ::..,. hey
r. ?�
��� � � �
��.���s��„
_��. .�,_,�_:
���.�.�:_:s��<,�,•��aw,��,����.�;f,,.
z t -: .f ., :.. .,.:1 : r F:'� ,,t�E '•w<'r -
f s g DESCRIPTION'ACCOUNT
y• v*, y 4; 1�.,u�va.;:zXE.i" �„
.'�':i7i:
f
flQTY
YAMOUNTRAID�5PAIDDATE
�.
WATER HEATER/VENT
101-000042#401
0,
$24.18
$0.00
y
f kaki: +k .c"Si.
x 4 PAID BY'r,rxMETHOD�x
:Y:` ' :y +','4Y �.AF'.fn,','§ a�.�'.v6'.yM, �`8v:1 ${ h;!
%Y` 2 9i• Ee
RECEIPT#C ysr S s'
Fk.,A
fg.
CHECKY# �s�
'�0j CLTD BY,Y
,
s,a
.....u.hE. s7....in,£':�.A�rcx��#Y. �'
"Gr.:9kTG�.£hf.
be.. - .,•.: 'F., -: -::. � `. `�. if�,�z�.. s
1 4
t�?;f�AGCOUNT�"C{Tl!�AMOUNT;s
�% � f � s'-u°�''...a�v � �.1'"'�€. z� :4 �' S �
4!, �:
z�M 3 �r
;-N,£N^'�,frt'-s �a _.+. - r
�, ' ..k'^
yDESCRIPTION
x PAID'
PAID,DATE
WATER HEATER/VENT PC'
' f -101-0000-42600
0
$14.50
$0.00
f eY. . T i ir' 4-d;r q
..l '4 . 4d„F£5h
iY” 'Fx`_Ci�b:.",•M'3' C.;yu Txz,
�
.?�.`&T,
LS -4-:n...a.5?.�i-.. may(i*
R
&577-5:�¢Y Rr�6
#
X3� 3). <:44 Y''jFTi •T?.,
CLTD
YV'.e,.
.METHOD
R 04'
CEIPr # <_s .."
I. CHECK
BY z s
:y �, \ t �'X 2.
, zDESCRIPTION Z ����
yaX�: :'��.v'a.` �' .{N',}t T $ "°''f
�
!,.rS�.i%E,+',�''-
QTY
"Y'T:FI ;h AAf'ic%✓Y
: $ "i'' .an
�
PAID
��
i+.$."....i°'!,.Q`^:`L..,#.a:+-<".C%$r'4'dX.,...ii'`E';5x_c•..
�AGCOUNT��?�y �
�
-DATE
WATER SYSTEM INST/ALT/REP
-101-0000-42401
0'
$12.09
$0:00
. C �£a .0 ;7-i-
PAIQ BY%
;''W
���METNOD %K
€ RECEIPT>#Ere
'CHECK#�
ACL°TD BYE
,
:...,A>�Hw
Y
'Y. �:..Y _30S3Z'� 43? ,:tt,dY.: --. 'dr .':..'X.:f:.
3..e•, .t
NO
-i: it. ...k.? }Y 4..11 ...:. :.k a..
TV, r
:1..h�t....:
a,3P'°,s
DESCRIPTION,£°':;,.1-x4
-T.y'°'s"G }: (Y, f�",-r
�.
�iir'
..."-"xfW.�#&3'-`5 C':'•a.�.
r tom.; 1'
,�&�S :X�3i.
T3
." ,ACCOUNT 5
�4TY��AMOUNTOIKINA
R
.7A�.�.,
�rPASIDDATE
WATER SYSTEM INST/ALT/REP PC
101-0000-42600
0
$12.09
$0.00
,< Y -, .:::'.:-.->e&"w:.�*ix.
s %3 PAID BY}fis"gr
tV1ETHOD:
�:..sa.c,rr:.o�:.s-ss__..3:aV,'�_.
�RECEIPT�#
-Es fcr
'
'.-E...?
s
�..L..'wss.tfr- :€.
BY
,..,j
,a.,:.}...-.,x.x-.:?.si.c.:
'
, ;--u.'�>'"
.CHECK#'�
,(3TD hr.
Total Paid for PLUMBING;FEES: .$913.97 $0.00
"DESCRIPTION <Y�ACCOU`NT;
}a'gh',Fr4j6£
:4 1 i"§;a' _.1"�Yrtrtf'Y'.�`5.`Y:Yi
AMOUNT.SY;
m -- 4�'
PAID DATE
w.•ry •r ..¢'..
:
5-P ,+•:+c3=.`::>+`3�±.F.Y:_3
^.yPAID
�v^4:.i�. i'�i'�.iS.RC
.
4R�. k..ptL,-Yh4
SMI -RESIDENTIAL
101-0000-20308
0
:$77:81
$0.00
<b &:E.
*, {PAID;BY Z"h
E
n`h�`� MEFHOD3�''RECEIPT#
<CFiEC1C#';'
LTDBYx
Total Paid for STRONG:MOTIONp INSTRUMENTATION SMI:.. $77.81 $0.00
DESCRtPT10N, �; £ b�'
sM�V'`fti .T,Y,Ett"'S,:R"'.'aa"F
f p� x ACCOUNT'S y'QTY�
ANIOUNT< "-12
� Yi) it<€FG Y S`
lPAIDf
fn..^ 4 !•'%:'"°s
PAID DATE
"'.?3hr.%.,�D
1K,�i.?5:t�s",..,#zf�?`x,v?
�i4aw?:ak
1sY
.
SINGLESFAMILYOETACHED
224-0000-20320
0
$1;837.44
$0.00
�r." - ei
',F,�, _ .. e<^t3? :.:y. fx..�.a.a'e;T
��
� RECEI?T
`CFtECK # a
CLTD BY
W ME HOD ll
Total Paid for TUMF - RESIDENTIAL: $1,837.44 $0.00'
o Y �� ��
Description: HIDEAWAY CLUB / NEW SFD / SUNROSE RESIDENCE
Type: BUILDING, RESIDENTIAL Subtype: DWELLING - SINGLE Status: APPROVED -CONDITIONS
Applied: 10/26/2015 MFA
FAMILY DETACHED
Approved: 1/8/2016 JJO
Parcel No: 777100070 Site Address: 80210 VIA CAPRI LA QUINTA,CA 92253
Subdivision: TR 29894-2 Block: Lot: 49
Issued:
Lot Sq Ft: 0 Building Sq Ft: 0 Zoning:
Finaled:
Valuation: $609,604.20 Occupancy Type: Construction Type:
Expired:
No. Buildings: 0 No. Stories: 0 No. Unites: 0
PLAN CHECK COMMENTS
Details: NEW 6605 SQ. FT. SFD. THIS PERMIT DOES NOT INCLUDE POOL, SPA, BLOCK WALLS, DRIVEWAY APPROACH, FIRE PIT, BBQ, OR
WATER FEATURE. HOME IS FIRE SPRINKLED PER 2013 CRC CODES.
so
Printed: Thursday, January 14, 2016 3:21:13 PM 1 of 6
SYSTEMS
ADDITIONAL
CHRONOLOGY
CHRONOLOGY TYPE
STAFF NAME
ACTION DATE
COMPLETION DATE
NOTES
PLAN CHECK COMMENTS
FROM CONSULTANT
KAY HENSEL
1/8/2016
1/8/2016
STRUC APPROVABLE 1/6/2016 - SEE NOTE ON TRANSMITTAL
RECEIVED
PLAN CHECK PICKED UP
STEPHANIE KHATAMI
11/19/2015
11/19/2015
ANTON
PLAN CHECK SENT TO
STEPHANIE GUM PERT
12/22/2015
12/22/2015
OUTSIDE PC
,
PLAN CHECK SUBMITTAL
STEPHANIE GUMPERT
12/22/2015
12/22/2015
RECEIVED
TELEPHONE CALL
JIM JOHNSON
11/17/2015
11/17/2015
CALLED SUNROSE CORP. TO INFORM THEM THE PLANS ARE
READY FOR CORRECTIONS.
CALLED SUNROSE CORP. TO INFORM THEM THE PLANS ARE
TELEPHONE CALL
JIM JOHNSON
1/8/2016
1/8/2016
READY TO ISSUE, NEED SCHOOL FEES, AND GRADING PLAN
NOT SIGNED
Printed: Thursday, January 14, 2016 3:21:13 PM 1 of 6
SYSTEMS
Permit Details PERMIT NUMBER
City of La Quinta BRES201�041=2
FINANCIAL
CONDITIONS
DESCRIPTION ACCOUNT QTY AMOUNT
PAID
PAID DATE RECEIPT # CHECK # METHOD PAID BY CLTD
BY
CONDITION
DATE
DATE DATE
Total Paid for ART IN PUBLIC PLACES - AIPP: $996.42 $0.00
HOURLY PLAN CHECK -
YES
101-0000-42600
5
$350.00
CONTACT
STATUS
REMARKS
NOTES
TYPE
ADDED
REQUIRED SATISFIED
101-0000-20306
0
$24.00
$0.00
READY TO ISSUE
JIM JOHNSON 1/7/2016.
PENDING
GRADING PLAN NOT SIGNED
CHECKLIST
252-0000-43200
0
-$942.00
$0.00
CONTACTS
254-0000-43200
0
$129.00
$0.00
NAME TYPE
NAME
ADDRESSI
CITY
STATE
0
ZIP
PHONE
FAX
EMAIL
APPLICANT
SUNROSE CORPORATION
72-850 SOMERA ROAD
PALM DESERT
CA
0
92260
(760)773-6633
CONTRACTOR
SUNROSE CORPORATION
72-850 SOMERA ROAD
PALM DESERT
CA
.92260
(760)773-6633
OWNER
MOUNTAIN WEST INVESTMENTS
40101 MONTEREY AVE
RANCHO
CA
92270
(760)773-6633
STE B1-214
MIRAGE
FINANCIAL
INFORMATION
DESCRIPTION ACCOUNT QTY AMOUNT
PAID
PAID DATE RECEIPT # CHECK # METHOD PAID BY CLTD
BY
ART IN PUBLIC PLACES -
RESIDENTIAL 270-0000-43201 0 $996.42
$0.00
Total Paid for ART IN PUBLIC PLACES - AIPP: $996.42 $0.00
HOURLY PLAN CHECK -
YES
101-0000-42600
5
$350.00
$0.00
Total Paid for BLDG CITY STAFF - PER HOUR: $350.00 $0.00
BSAS SB1473 FEE
101-0000-20306
0
$24.00
$0.00
Total Paid for BUILDING STANDARDS ADMINISTRATION $24.00 $0.00
BSA:
DIF - CIVIC CENTER
252-0000-43200
0
-$942.00
$0.00
DIF - COMMUNITY
CENTERS
254-0000-43200
0
$129.00
$0.00
DIF - FIRE PROTECTION
257-0000-43200
0
$433.00
$0.00
DIF - LIBRARIES
253-0000-43200
0
$344.00
$0.00
Printed: Thursday, January 14, 2016 3:21:13 PM 2 of 6 j■1�ai�' SYSTEMS
• CR?IrJ L
Printed: Thursday, January 14, 2016 3:21:13 PM 3 of 6 CPEAJF
EFEF SYSTEMS
CLTD
DESCRIPTION
ACCOUNT
QTY
AMOUNT.
PAID
PAID DATE
RECEIPT #
CHECK #
METHOD
PAID BY
BY
DIF - PARK
256-0000-43200
0
$40.00
$0.00
MAINTENANCE
DIF - PARKS/REC
251-0000-43200
0
$2,048.00
$0.00
DIF - STREET
255-0000-43200
0
$116.00
$0.00
MAINTENANCE
DIF -TRANSPORTATION
250-0000-43200
0.
$2,842.00
$0.00
Total Paid for DIF - SINGLE FAMILY DWELLING: $6,894.00 $0.00
TEMP POWER SERVICE
101-0000-42403
0
$24.17
$0.00
TEMP POWER SERVICE
101-0000-42600
0
$16.92
$0.00
PC
Total Paid for ELECTRICAL: $41.09 $0.00
RESIDENTIAL, EA
101-0000-42403
0
$98.64
$0.00
ADDITION 1,000SF
RESIDENTIAL, EA
101-0000-42600
0
$40.64
$0.00
ADDITION 1,000SF, PC
RESIDENTIAL, FIRST
101-0000-42403
0
$145.03.
$0.00
.. 1,000SF
RESIDENTIAL, FIRST
101-0000-42600
0
$47.86
$0.00
1,000SF, PC
Total Paid for ELECTRICAL - NEW CONSTRUCTION: $332.17 $0.00
RESIDENTIAL PRECISE
GRADING - CUSTOM
101-0000-42408
0
$36.26
$0.00
HOME LOT>7KSF
RESIDENTIAL PRECISE
GRADING - CUSTOM
101-0000-42600
0
$181.29
$0.00
HOME LOT >7KSF PC
Total Paid for GRADING: $217.55 $0.00
CONDENSER/COMPRES
101-0000-424020
$181.30
$0.00
SOR
Printed: Thursday, January 14, 2016 3:21:13 PM 3 of 6 CPEAJF
EFEF SYSTEMS
tt' Permit Details PERMIT NUMBER
City of La Quinta BREs2015-0412
DESCRIPTION
ACCOUNT
CITY
AMOUNT
PAID
PAID DATE
RECEIPT #
CHECK #
METHOD
PAID BY
CLTD
'BY' BY
CONDENSER/COMPRES
SOR PC
101-0000-42600
0
$120.85
$0.00
EXHAUST HOOD
101-0000-42402
0
$12.09
$0.00
EXHAUST HOOD PC
101-0000-42600
0
$4.83
$0.00
FURNACE
101-0000-42402
0
$181.30
$0.00
FURNACE PC
101-0000-42600
0
$120.85
$0.00
VENT FAN
101-0000-42402
0
$108.81.
$0.00
VENT FAN PC
101-0000-42600
0
$43.47
$0.00
WALL HEATER
101-0000-42402
0
$148.26
$0.00
WALL HEATER PC
101-0000-42600
0
$72.54
$0.00
Total Paid for MECHANICAL: $994.30 $0.00
NEW CONSTRUCTION
PERMIT
101-0000-42400
0
$805.01
$0.00
Total Paid for NEW CONSTRUCTION PERMIT: $805.01 $0.00
NEW CONSTRUCTION
PLAN CHECK
101-0000-42600
0
$1,500.00
$1,500.00
10/26/15
R10259
2012
CHECK
SUNROSE
CORPORATION
MFA
NEW CONSTRUCTION
PLAN CHECK
101-0000-42600
0
$243.48
$0.00
.Total Paid for NEW CONSTRUCTION PLAN CHECK: $1,743.48 $1,500.00
BACKFLOW DEVICE
101-0000-42401
0
$12.09
$0.00
BACKFLOW DEVICE PC
101-0000-42600
0
$4.83
$0.00
BUILDING SEWER
101-0000-42401
0
$12.09
$0.00
BUILDING SEWER PC
101-0000-42600
0
$12.09
$0.00
FIXTURE/TRAP
101-0000-42401
0.
$374.79
$0.00
FIXTURE/TRAP PC
101-0000-42600
0
$374.79
$0.00
Printed: Thursday, January 14, 2016 3:21:13 PM 4 of 6 cp
EVEY SYSTEMS
DESCRIPTION
ACCOUNT
QTY
AMOUNT
PAID
PAID DATE
RECEIPT #
CHECK #
METHOD
PAID BY
CLTD
DATE
1ST BLDG NS (3 WK)
JIM JOHNSON
10/26/2015
11/16/2015
11/17/2015
BY
GAS SYSTEM, 5+
101-0000-42401
0
$36.26
$0.00
11/16/2015
11/16/2015
REVISIONS REQUIRED
WK)
OUTLETS
GAS SYSTEM, 5+
101-0000-42600
0
$24.17
$0.00
OUTLETS PC
WATER HEATER/VENT
101-0000-42401
0
$24.18
$0.00
WATER HEATER/VENT
101-0000-42600
0
$14.50
$0.00
PC
WATER SYSTEM
101-0000-42401
0.
$12.09
$0.00
INST/ALT/REP
WATER SYSTEM
01-0000-42600
10
0
$12.09
$0.00
INST/ALT/REP PC
Total Paid for PLUMBING FEES: $913.97 $0.00
SMI - RESIDENTIAL
101-0000-20308
0
$77.81
$0.00
Total Paid for STRONG MOTION INSTRUMENTATION SMI: $77.81 $0.00
SINGLE FAMILY .
224-0000-20320
0 j
$1,837.44
$0.00
DETACHED
Total Paid for TUMF - RESIDENTIAL: $1,837.44 $0.00
TOTALS': $15,227.24 $1'suum
REVIEW TYPE
REVIEWER
SENT DATE
DUE DATE
RETURNED
REVIEWS
STATUS '
REMARKS
NOTES
-
DATE
1ST BLDG NS (3 WK)
JIM JOHNSON
10/26/2015
11/16/2015
11/17/2015
REVISIONS REQUIRED
IST BLDG STR (3
JOHN
10/26/2015
11/16/2015
11/16/2015
REVISIONS REQUIRED
WK)
THOMPSON
Printed: Thursday, January 14, 2016 3:21:13 PM 5 of 6 cl?
sysrrms
Permit Details PERMIT NUMBER., l
BRES201'5-10412`,...
City of la Quinta �
1ST PW GREEN
AMY YU
12/8/2015
12/15/2015
12/11/2015
READY FOR APPROVAL
PM2013-534
SHEET
Attachment Type
'CREATED
OWNER
DESCRIPTION
PATHNAME
2ND BLDG NS (2
JIM JOHNSON
12/22/2015
1/11/2016
1/8/2016
APPROVED
80-210 VIA CAPRI.docx
WK)
DOC
11/17/2015
JIM JOHNSON
80-210 VIA CAPRI.pdf
80-210 VIA CAPRI.pdf
0
2ND BLDG STR (2JOHN
'THOMPSON
12/22/2015
1/11/2016
1/6/2016
READY FOR APPROVAL
WK)
1ST REVIEW -
DOC
11/14/2015
Printed: Thursday, January 14, 2016 3:21:13 PM 6 of 6
SYSTEMS
BOND INFORMATION
ATTACHMENTS
Attachment Type
'CREATED
OWNER
DESCRIPTION
PATHNAME
SUBDIR
ETRAKIT ENABLED
DOC
11/17/2015
JIM JOHNSON
80-210 VIA CAPRI.docx
80-210 VIA CAPRI.docx
0
DOC
11/17/2015
JIM JOHNSON
80-210 VIA CAPRI.pdf
80-210 VIA CAPRI.pdf
0
LQ PC
1ST REVIEW -
DOC
11/14/2015
JOHN THOMPSON
STRUCTURAL
TRANSMITTAL_BRES201
0
TRANSMITTAL.pdf
5_0412_1ST_11-14-
15.pdf
1ST REVIEW -
1ST REVIEW -
DOC
11/14/2015
JOHN THOMPSON
STRUCTURAL SOIL
STRUCTURAL SOIL
0
REQUIREMENTS.pdf
REQUIREMENTS.pdf
IST REVIEW -
1ST REVIEW -
.DOC
•11/15/2015
JOHN THOMPSON
STRUCTURAL
STRUCTURAL
0
COMMENTS.doc
COMMENTS.doc
2ND REVIEW -
2ND REVIEW -
DOC
1/6/2016
JOHN THOMPSON
STRUCTURAL
STRUCTURAL
0
TRANSMITTAL.pdf
TRANSMITTAL.pdf
DOC
12/8/2015
STEPHANIE GUMPERT
GRANT DEED 12-08-
GRANT DEED 12-08-
0
15.pdf
15.pdf
DOC
12/8/2015.
STEPHANIE GUMPERT
DEBRIS MANAGEMENT
DEBRIS MANAGEMENT
0
PLAN 12-08-15.pdf
PLAN 12-08-15.pdf
DOC
12/11/2015
STEPHANIE KHATAMI
PM10 - 80210 VIA CAPRI
PM10 - 80210 VIA CAPRI
0
12-11-IS.pdf
12-11-15.pdf
Printed: Thursday, January 14, 2016 3:21:13 PM 6 of 6
SYSTEMS
P.O. BOX 1504 APPLICATION ONLY
78 495 CALLS TAMPICO
Building
Address 2 (.e' 6 1114-" 5 O .�� /o 1 / �i LA QUINTA, CALIFORNIA 92253
(/
Owner
lyPKIII-M1 BUILDING: TYPE CONST. OCC. GRP.
Mailing _ I
Address 7-2 -7 r /O0 Q ZO 7 A.PNumber
c p
City Zip Tel. Legal Description
7� a �l� .� 2 7 v
1760 7Z -66-5 3� �
Contractor`2,� 1i—
�j Project Description P fEkrz 60-u G7` 0' r.., JI C— (%
Address
City , Zip Tel.
% 773 6633
State Lie. City
& Classif. Lie. #
Designer
Lie. #
LICENSED CONTRACTOR'S DECLARATION
I hereby affirm that I am licensed under provisions of Chapter 9 (commencing with Section 7000)
oI Division 3 of the Business and Professions Code, and my license is in full force and effect.
SIGNATURE DATE
OWNER -BUILDER DECLARATION
I hereby affirm that I am exempt from the Contractor's License Law for the following reason:
(Sec. 7031.5, Business and Professions Code: Any city or county which requires a permit to construct,
alter, improve, demolish, or repair any structure, prior to its issuance also requires the applicant for
such permit to file a signed statement that he is licensed pursuant to the provisions of the Contrac-
tor's License Law, Chapter 9 (commencing with Section 7000) of Division 3 of the Business and
Professions Code, or that he is exempt therefrom, and the basis for the alleged exemption. Any
violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of
not more than five hundred dollars ($500).
❑ I, as owner of the property, or my employees with wages as their sole compensation, will do
the work, and the structure is not intended or offered for sale. (Sec. 7044, Business and Profes-
sions Code: The Contractor's License Law does not apply to an owner of property who builds or
improves thereon and who does such work himself or through his own employees, provided that
such improvements are not intended or offered for sale. If, however the building or improvement
is sold within one year of completion, the owner -builder will have the burden of proving that he did
not build or improve for the purpose of sale).
❑ I, as owner of the property, am exclusively contracting with licensed contractors to construct the
project. (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply
to an owner of property who builds or improves thereon, and who contracts for such projects with
a contractor(s) licensed pursuant to the Contractor's License Law)
❑ 1 am exempt under Sec. B. & P.C. for this reason
Date Owner
WORKER'S COMPENSATION DECLARATION
I hereby affirm that I have a certificate of consent to self -insure, or a certificate of Worker's
Compensation Insurance, or a certified copy thereof. (Sec. 3800, Labor Code.)
Policy No. Company
❑ Copy is filed with the city. ❑ Certified copy is hereby furnished.
CERTIFICATE OF EXEMPTION FROM
WORKERS' COMPENSATION INSURANCE
(This section need not be completed it the permit is for one hundred dollars ($100) valuation
or less).
I certify that in the performance of the work for which this permit is issued, I shall not employ
any person in any manner so as to become subject to Workers' Compensation laws of California.
Date Owner
NOTICE TO APPLICANT.. If, after making this Certificate of Exemption you should become
subject,to the Workers' Compensation provisions of the Labor Code, you must forthwith
comply with such provisions or this permit shall be deemed revoked.
CONSTRUCTION LENDING AGENCY
I hereby affirm that there is a construction lending agency for the performance of the work for
which this permit is issued. (Sec. 3097, Civil Code.)
Lender's Name
Lender's Address
This is a building permit when properly filled out, signed and validated, and is subject to
expiration if work thereunder is suspended for 180 days.
I certity that I have read this application and state that the above information is correct.
I agree to comply with all city and county ordinances and state laws relating to building
construction, and hereby authorize representatives of this city to enter the above-mentioned
property for inspection purposes.
Signature of applicant Date
Mailing Address
City, State, Zip
WHITE = BUILDING DEPARTMENT
Sq. Ft. AA No. No. Dw.
Size f0 6 Stories Units
New IO/ Add ❑ Alter ❑ Repair ❑ Demolition ❑
Estimated Valuation
PERMIT AMOUNT
Plan Chk. Dep.
Plan Chk. Bal.
Const.
Mech.
Electrical
Plumbing
S.M.I.
Grading
Driveway Enc.
Infrastructure
TOTAL
CONTACT INFORMATION
NAME:
PHONE:
ZONE: BY:
Minimum Setback Distances:
Front Setback from Center Line —
Rear Setback from Rear Prop. Line —
Side Street Setback from Center Line
Side Setback from Property Line
FINAL DATE—
Issued by:
Validated by: —
Validation:
YELLOW = APPLICANT
INSPECTOR
Date Permit
PINK = FINANCE
RECORDING REQUESTED BY:
Title 365
AND WHEN RECORDED MAIL TO:
Mountain West Investment Corp
201 Ferry Street NE
Salem, OR 97301
Order No.: 510.1501497-51
Escrow No.: FS960
A.P.N.: 777.100.078 TRA 020.160 i
SPACE ABOVE
GRANT'DEED
DOC # 2015-0158659
04/20/2015 03:30 PM Fees: $28.00
Page 1 of 2 Doc T Tax Paid
Recorded in Official Records
County of Riverside
Peter Aldana
Assessor, County Clerk & Recorder
""This document was electronically submitted
to the County of.Riverside for recording"
Receipted by: SGOMEZ
REC
THE UNDERSIGNED GRANTOR(S) DECLARE(S)
DOCUMENTARY TRANSFER TAX IS $ l , �G45
[ X ] computed on full value of property conveyed, or
[ ] computed on full value less value of liens or encumbrances remaining at time of sale.
[ ] unincorporated area [ X ] City of La Quinta
FOR A VALUABLE CONSIDERATION, receipt of which is hereby acknowledged,
Discover Investments, LLC I
hereby GRANTS) to Mountain West Investment Corporation, an Oregon Corporation
the following described real property in the County of Riverside, State of California
See Exhibit "A" attached hereto and made a part hereof. le,
Commonly known as: Lot 48/49 and Lot 50/51 (APN 777-100-078) , La Quinta, CA 92253
Dated: April 1, 2015
A notary public or other officer completing this certificate
verifies only the Identity of the individual who signed the
document to which this certificate is attached, and not the
truthfulness, accuracy, or validity of that document.
STATE OF CALIFORNIA
COUNTY OF GE=—
On IPPR(t— I Zn before me,
0 a no a public,
personally appeared T(
who proved to me on the basis of satisfactory evidence to be the
person(s) whose name(s) is/are subscribed to the within
instrument and acknowledged to me that he/she/they executed
the same in his/her/their authorized capacity(les), and that by
his/her/their signature(s) on the instrument the person(s), or the
entity upon behalf of which the person(s) acted, executed the
instrument.
I certify under PENALTY OF PERJURY under the laws of the
State of California that the foregoing paragraph Is true and
correct.
DEC � $ 2015
et" of
4� p,�1NTA ENS
ON►M N N���opM
C
Disco estments
By: Aut onze er
ss. ,�. 1if a rce
-------------------
LEESA MERRIIL-LOEFKE
Commisslon # 2079142
Notary Public - Calaornla
Orange County
My Comm. Expires Aug22, 2010
WITNESS my hand and official eal.
Signature (Seal)
(This area for official notary seal)
MAIL TAX STATEMENTS AS DIRECTED ABOVE
5
DOC #2015-0158659 Page 2 of 2 04/20/2015 03:30 PM
EXHIBIT A
Legal Description
The land hereinafter referred to Is situated in the City of La Quinta, County of Riverside, State of CA, and is described as
follows:
Parcel "A"
Lots 48 and 49 of Amended Tract No. 29894-2, in the City of La Quinta, County of Riverside, State of California as per
map recorded In Hook 327, Pages 56 through 88, inclusive and amended No. 2 of said Tract No. 29894-2, per map
recorded In Book 359, Pages 68 through 82, inclusive of Maps, In the Office of the County Recorder of said County as
shown on Parcel Merger No. 2003-418 recorded April 14, 2003 as Instrument No. 2003-260930, Official Records;
Together with Lots 50 and 51 of said Amended Tract No. 29894-2, as shown on Parcel Merger No. 2003-419 recorded
April 14, 2003 as Instrument No. 2003-260931, Official Records, described as a whole as follows:
Beginning at the Northwest corner of said Parcel Merger No. 2003-418;
Thence N 41 degrees 01 minutes 08 seconds E, along the North line of said Parcel Merger No. 2003-418, a distance of
53.13 feet to the beginning of a non -tangent curve, a radial line to said non -tangent curve bears N 54 degrees 38 minutes
19 seconds W;
Thence Northeasterly along said curve concave to the Southeast through a central angle of 29 degrees 00 minutes 33
seconds a radius of 430.00 feet and an are length of 217,71 feet to the Northeast corner of said Parcel Merger No.
2003-419;
Thence S 23 degrees 14 minutes 42 seconds E, along the East line of Parcel Merger No. 2003-419, a distance of 150.20
feet to the Southeast corner of said Parcel Merger 2003-419 and a point on a non -tangent curve whose radial line bears S
26 degrees 54 minutes 29 seconds E, said curve having a radius of 280.00 feet;
Thence Southwesterly along said curve concave to the Southeast through a central angle of 27 degrees 53 minutes 17
seconds an arc length of 136.29 feet to a point of reverse curvature;
Thence Southwesterly along said reverse curve concave to the Northwest through a central angle of 12 degrees 20
minutes 07 seconds a radius of 400.00 feet an arc length of 86.12 feet to the Southwest corner of said Parcel Merger No.
2003-418;
Thence N 41 degrees 46 minutes 53 seconds W, along the West line of said Parcel Merger 2003-418, a distance of
150.00 feet to the Northwest corner of said Parcel Merger No. 2003418 and the true point of beginning.
Merged Parcel containing 37,050 sq. ft., (0.85 acres) more or less
ON: 777-100-070-9
APN: 777-100-071-0
Exhlbit A Created: 03/25/2015 510.1501497-51
139..c--5 215-0�/
CITY OF LA QUINTA - PUBLIC WORKS DEPARTMENT GREEN SHEET
PUBLIC WORKS CLEARANCE FOR RELEASE OF BUILDING PERMIT
Form updated & effective 9/25/2009
Green Sheet approvals are forwarded to the Building & Safety Department directly by Public Works. Please DO NOT
submit the Green Sheet (Public Works Clearance) Packet to the Public Works Department until ALL requirements listed
a below are complete. Incomplete applications or applications which cannot be processed will be returned to applicant.
Date: 12 / 04 / 15 Developer: Sunrose Corporation
Tract No.: 29894-2
Tract Name: The Hideaway Lot No. (s): 48/49-50/51
Address(s): 80210 Via Capri
Phone Number:( 60 ) 773-6633
The following are the requirements for Public Works Clearance to authorize issuance of a building permit from the
Building & Safety Department:
❖ CUSTOM HOMES: PROVIDE ITEMS #2. #3, #4, #5 & #7 BELOW
❖ TRACT HOMES: PROVIDE ITEMS #1, #2, #3 & #5 BELOW
❖ COMMERCIAL BUILDINGSIOTHER: PROVIDE ITEMS #1 #2 #3 #5 & #7 BELOW
❖ WALLS, SIGNS, OTHER: PROVIDE ITEM #6 BELOW
1. Attach Pad Elevation Certificates in compliance with the approved design elevation for building pad (maximum
allowable deviation of +/- 0.1 foot). Pad Elevation Certificates must be current (within 6 months of current date).
If a precise grading plan creates the pad for approval, please withhold green sheet submittal until a Pad Elevation
Certificate can be provided.
2. Attach geotechnical certification of grading plan compliance including compaction reports from a licensed Soils
Engineer. Recently rough graded residential developments which have a previously approved geotechnical
certification are exempt from this requirement.
3. Attach recorded final map or title information/grant deed showing proposed building locations are legal lots.
4. Complete the attached <1 acre per lot or infill project Fugitive Dust Control project information form, PM10 plan &
agreement or provide alternative & valid City approved PM10 plan set reference number or hard copy plan.
PM10 plans for commercial & residential developments (beyond 1 lot) are submitted separately with grading plans
& are subject to additional requirements. A current PM10 certification number is required.
5. Attach a copy of the rough or precise grading plan to the Public Works Department showing building location(s)
for pad elevation verification. AO flood zone developments will require an approved flood plain development plan.
6. Attach supporting documentation for wall plan, monument sign, grease trap or special facility installations.
7. Complete and sign the attached water quality management plan (WQMP) exemption form, if applicable. PW
approved building construction projects require either a WQMP or a completed WQMP exemption form.
Approved maps/plans may be viewed at the following link: http://www.la-guinta.orq/PlanCheck/m search.aspx
I have reviewed and confirmed the requirements listed above as presented and find the improvements to be sufficiently
complete for construction of the proposed buildings/structures/walls/signs on the subject lot(s). Pursuant to my findings,
the above project may be released for building permit issuance.
This section completed by City staff.
Recommended by: Date: /2- /(/ //5
Public Works Distribution: (Z) Green Sheet to Building & Safety
( ) Green Sheet to Planning Department
Declined for approval for reason(s) as follow(s), please correct and resubmit:
T:\Checklists - Fors & Applications\Fors & Applications\GREEN SHEET cover & PM10 less than 1 Acre Revised 9-25-09.doc
t
'R
City of La Quinta - PM10 Fugitive Dust Control Project Information
Construction Phase PM10 Agreement <1 acre/lot or Infill Project
Project Information
Project Contractor: Sunrose Corporation
Project Phase
(check one)
Construction
Demolition
Project Name: Mountain West Investments
Project Tract/Lot Numbers: 29894-2
Project Street Address: 80210 Via Capri
Total Acres in Active
Construction (<1 acre per
Lot): 37,050 sq. ft
12 04 15 12 04 15
Anticipated Start Date: / / Anticipated Completion Date: / /
PM10 Contact
Information
Please note: Dust control is required 24 hours a day, 7 days a week, regardless of
construction status. Person listed below is responsible for dust control during business and
non -business hours.
Name:
Jenny McIntire
Title:
Administration
Company Name:
Sunrose Corporation
Mailing Address:
40101 Monterey Ave, #131-214
City, State, ZIP Code:
Rancho Mirage, CA 92270
Primary Phone #:
760-773-6633
Fax #:
760-773-6634
24 Hour Emergency
Phone#:
760-773-6633
Cell Phone #:
760-702-0119
Email Address:
sunrose.sedona@gmail.com
PM10 Certificate #:
CV1402-000405-449
The above stated property owner (or authorized representative):
❖ Shall act as his/her acknowledgement of dust control requirements and their enforceability, pursuant to SCAQMD
Rules 403, 403.1, 401, 402, 201, 203 and PERP;
❖ Shall constitute an Agreement to comply with all project conditions as identified in the approved dust control plan.
❖ Acknowledges that dust control is required twenty-four (24) hours a day, seven (7) days a week, throughout the
period of project performance, regardless of project size or status;
❖ Shall ensure that each and every contractor, subcontractor and all other persons associated with the project shall
be in continuous compliance with all requirements of the approved dust control plan;
❖ Shall take all necessary precautions to minimize dust, even if additional measures beyond those listed in the dust
control plan are necessary;
❖ Shall authorize representatives of City/County to enter the property for inspection and/or abatement purposes;
❖ Shall hold harmless the City/County and its representatives from liability for any actions related to this dust control
plan -or-any City/County initiated abatement activities.
of Pro y Owner or Authorized Representative Date
TAChecklists - Forms & ApplicalionsWorms & Applications\GREEN SHEET cover & PM10 less than 1 Acre Revised 9-25-09.doc
Plan Submittal
Job Site
Owner's N
Number, Street, or PO
City, State, Postal C
Owners Phone Nur
Owners E -Mail Add
Project Managers
Project Manager's Phone N
Project Manager's E-mail Ai
Builder / Contn
Number, Street or PO
City, State, Postal (
Project Square
Building Permit Number.
Project Description: SFR
Exempt: 13
(Materials may contain hazardous wastes and
are not subject to recycling provisions)
Construction Debris Management Plan
City Approval By
Date of City Approval
Materials To Be Discarded:
Product
Trash
Asphalt
Brick/Block
Cardboard
Commingled
Concrete
Drywall
Donated / Reuse'
'Describe Items
11/9/2015
Via Capri Lot 48/49-50/51
Mountain West Investments c/o Sunrose Corporation
40101 Monterey Avenue Suite B1-214
Rancho Mirage, CA 92270
Mike Tuvell
760-702-0119
.sun rose.sedona(@-gmail.com
Sunrose Corporation
40101 Monterey Avenue, Suite B1-214
Rancho Mirage, CA 92270
Tons
12.55 1 Not recyclable
0.53 Recyclable
0.39 Recyclable
0.00 Recydabte
Totals: Recycle Trash
22.1 1 12.5
Product
Masonry (broken)
Plaster
Scrap Metal
Tile (floor)
Tile (roof)
Wood
Landscape Debris
fIN�®
vtf
DEC o a 205
CI'N 0f p0E�OpMENT
C�MM�p1'N
Tons
0.00 Recyclable
1.32 Recyclable
0.00 Recyclable
1.12 Recyclable
0.00 Recyclable
16.51 Recyclable
0.00 Recyclable
Projected Diversion:
F 83.7%
1 understand it is the property owner's responsibility to submit copies of weight tickets or receipts to the District
Environmental Coordinator as these hauls occur. I hereby certify that compWm, Implementation and adherence of the
Debris Management Plan (DMP) for the above named project shaft guarantee that at least 50% of the jobsite waste is diverted
from landfilling. The remaining material will be recycled or reused. I will divert, for recycling or re -use, remaining materials
generated from the first day of the project through the completion of the project in accordance with this plan. This DMP Is Issued
In the name of the property owner(s) and shag remain their property throughout the construction and/or demolition project. A
contractor serving as agent of the owner may obtain a DMP for the owner. However, the DMP is still issued In the name of the
property, owner(s) and the owner retains legal responsibility for ensuring that the provisions of the DMP are adhered to. The
property owner(s) and general contractor shall be kept informed of the diversion progress through bi-monthly reports. if self -
hauling, all refuse material from this project site must be taken to an approved recycler or transfer station.
Owner / Developer / Project Manager / Superintendant Date
BUILDING ENERGY ANALYSIS REPORT
= PROJECT: - .. .
• - A New Residence -
Lots 48-51, The Hideaway
La Quinta, CA 92253. rerwoe.,
R�
Project Desi ner:W
5R4Y
Stracts Architects
550.S. Oleander -
Palm Springs, CA 92262
(760) 636-8951
Report Prepared by:
Tim Scott '
Scott Design and Title 24,, -Inc,
r 77085 Michigan Drive
Pal 92
LA QUINTS!
'BUILDING & SAFETY DEPT.
APPROVED
FOR CONS RUCTION
DATEBY ,
_ w®
b Numb r:
Date: Crt`�N,N p V�i�oox
12/17/2015
The EnergyPro computer program has been used to perform the calculations summarized in this compliance report..This program has approval and is
authorized by the California Energy Commission for use with both the Residential and Nonresidential 2013 Building Energy Efficiency Standards.
• This program developed by EnergySoft, LLC — www.energysoft.com.
EnergyPro 6.7 by EnergySoft User Number: 6712 ID:
CERTI'PE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE iOD
Project 'PE
New Residence Ca culation Date/Time: 08:10, Thu, Dec 17, 2015
Calculation Description: Title 24 Analysis
Input File Name: Hideaway Lot 48-51 -Stracts-1 5.xml
CF PRF -01
Page 1 of 13
GENERAL INFORMATION
01
01
Project Name New Residence
02
This building incorporates features that require field testing and/orverification by a certified HERS rater under the supervision of a CEC-approved HERS provider.
St 1', tL ll L)1'.. -� t1 fL IM 11 J1 it
02
Calculation Description Title 24 Analysis
08
Energy Use (kTDV/ft2-yr)
03
Project Location Lots 48-51, The Hideaway
Compliance Margin
Percent Improvement
04
City La Quinta
05
Standards Version Compliance 2015
06
Zip Code 92253
07
Compliance Manager Version BEMCmpMgr 2013-4 (744)
08
Climate Zone CZ15
09
Software Version EnergyPro 6.6
10
Building Type Single Family
11
Front Orientation (deg/Cardinal) 135
12
Project Scope Newly Constructed
13
Number of Dwelling Units 1
14
Total Cond. Floor Area (ft2) 6605
15
Number of Zones 4
16
Slab Area (ft) 6605
17
Number of Stories 1
18
Addition Cond. Floor Area N/A
19
Natural Gas Available Yes
20
Addition Slab Area (ft2) N/A
21
Glazing Percentage (%) 36.0%
COMPLIANCE RESULTS
01
Building Complies with Computer Performance
02
This building incorporates features that require field testing and/orverification by a certified HERS rater under the supervision of a CEC-approved HERS provider.
St 1', tL ll L)1'.. -� t1 fL IM 11 J1 it
03
This building incorporates one or',more Special Features shown'below
08
Energy Use (kTDV/ft2-yr)
Standard Design
Registration Number: 215-N6305400B-000000000-0000 Registration Date/Time: 2015-12-17 08:33:11 HERS Provider: C8ICERTS inc.
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-08252015-744 Report Generated at: 2015-12-17 08:11:33
ENERGY USE SUMMARY
04
05
06
07
08
Energy Use (kTDV/ft2-yr)
Standard Design
Proposed Design
Compliance Margin
Percent Improvement
Space Heating
5.59
6.47
-0.88
-15.7%
Space Cooling
127.80
110.56
17.24
13.5%
IAQ Ventilation
0.75
0.75
0.00
0.0%
Water Heating
3.89
5.55
-1.66
-42.7%
Photovoltaic Offset
----
0.00
0.00
--
Compliance Energy Total
138.03
123.33
14.70
10.6%
Registration Number: 215-N6305400B-000000000-0000 Registration Date/Time: 2015-12-17 08:33:11 HERS Provider: C8ICERTS inc.
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-08252015-744 Report Generated at: 2015-12-17 08:11:33
CERTI#E OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE POD CFORF-01
Project ame: New Residence Calculation Date/Time: 08:10, Thu, Dec 17, 2015 Page 2 of 13
Calculation Description: Title 24 Analysis Input File Name: Hideaway Lot 48-51-Stracts-15.xm1
REQUIRED SPECIAL FEATURES
The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis.
• Window overhangs and/or fins
HERS FEATURE SUMMARY
The following is a summary of the features that must be field -verified by a certified HERS Rater as a condition for meeting the modeled energy performance for this computer analysis. Additional detail is
provided in the building components tables below.
Building -level Verifications:
• Building Envelope Air Leakage
• IAQ mechanical ventilation
Cooling System Verifications:
• Minimum Airflow
• Verified EER
• Verified SEER
• Refrigerant Charge
• Fan Efficacy Watts/CFM
HVAC Distribution System Verifications:
• Duct Sealing
• Verified low -leakage ducts entirely in conditioned space
Domestic Hot Water System Verifications: n
•
--None
01 1 11 11 1 e
ENERGY DESIGN RATING \ � d U U n V b 0 \� 0
This is the sum of the annual TDV energy consumption foreA ergy use,_compdrients�includled in the'perfor ance complliahce approach4or the -Standard Design Building (Energy Budget) and the annual
TDV energy consumption for lighting and components not regulated by Title 24, Part�6 (such as domestic appliances and consumer electronics) and accounting for the annual TDV energy offset by an
on-site renewable energy system.
Reference Energy Use Energy Design Rating Margin Percent Improvement
Total Energy (kTDV/f2-yr)* 173.15 158.45 14.70 8.5%
* includes calculated Appliances and Miscellaneous Energy Use (AMEU)
BUILDING - FEATURES INFORMATION
01
02
03
04
05
06
07
Project Name
Conditioned Floor Area (ft2)
Number of Dwelling
Units
Number. of Bedrooms
Number of Zones
Number of Ventilation
Cooling Systems
Number of Water
Heating Systems
New Residence
6605
1
5
4
0
2
Registration Number: 215-N6305400B-000000000-0000 Registration Date/Time: 2015-12-17 08:33:11 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-08252015-744 Report Generated at: 2015-12-17 08:11:33
CERTI'PE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE �OD
Project
'PE
New Residence Ca culation Date/Time: 08:10, Thu, Dec 17, 2015
Calculation Description: Title 24 Analysis
Input File Name: Hideaway Lot 48-51 -Stracts-1 5.xml
CFORF-01
Page 3 of 13
ZONE INFORMATION
01
02
03
04
05
06
07
Zone Name
Zone Type
HVAC System Name
Zone Floor Area
(ft2)
Avg. Ceiling
Height
Water Heating System 1
Water Heating System 2
master Zone
Conditioned
HVAC 11
1586
9
DHW Sys 1
Window & Door Area (ft2)
grt din kit zone
Conditioned
HVAC 2,32
3134
9
DHW Sys 1
1020
bed
Conditioned
HVAC 43
722
9
DHW Sys 1
Front
casita zone
Conditioned
HVAC 54
1163
9
DHW Sys 3
225
OPAQUE SURFACES
01
02
03
04
05
06
07
08
Name
Zone
Construction
Azimuth
Orientation Gross Area (ft2)
Window & Door Area (ft2)
Tilt (deg)
NE Wall
master Zone
R-21 Wall (W.19.2x6.16)
45
Right
1020
102
90
SE Wall
master Zone
R-21 Wall (W.19.2x6.16)
135
Front
625
112
90
SW Wall
master Zone
_ R_-21 Wall (W.19.2x6._16)
225
Left
625
75
90
NW Wall
master Zone
r� s R'21�Wall�(W.19.2x616)
_ . ,
(315
tBack
, 1020
160
90
R-38 Roof
master'Zone
R-38 Roof(R'38.2x1y4-16)
a
1586
NE Wall 2
grt di—n kit'zone
~ _ R-21 Wall (1N.19.2x6.16)}
45 fif
Right
T 1000
24
90
SE Wall 2
grt din kit zone
t L-- R-21 Wall (W. 1 9.2z6.16)%
135
Front
r : 2375
524.34
90
SW Wall 2
grt din kit zone
R-21 Wall (W.19.2x6.16)
225
Left
1200
386
90
NW Wall 2
grt din kit zone
R-21 Wall (W.19.2x6.16)
315
Back
1800
443
90
R-38 Roof 2
grt din kit zone
R-38 Roof(R.38.2x14.16)
3134
NE Wall 3
bed
R-21 Wall (W.19.2x6.16)
45
Right
725
72
90
SE Wall 3
bed
R-21 Wall (W.19.2x6.16)
135
Front
875
42
90
SW Wall 3
bed
R-21 Wall (W.19.2x6.16)
225
Left
875
29
90
NW Wall 3
bed
R-21 Wall (W.19.2x6.16)
315
Back
875
136
90
R-38 Roof 3
bed
R-38 Roof(R.38.2x14.16)
722
NE Wall 4
casita zone
R-21 Wall (W.19.2x6.16)
45
Right
375
86
90
SE Wall 4
casita zone
R-21 Wall (W.19.2x6.16)
135
Front
720
27
90
SW Wall 4
casita zone
R-21 Wall (W.19.2x6.16)
225
Left
375
48
90
NW Wall 4
casita zone
R-21 Wall (W.19.2x6.16)
315
Back
720
136
90
R-38 Roof 4
casita zone
R-38 Roof(R.38.2x14.16)
1163
Registration Number: 215-N6305400B-000000000-0000 Registration Date/Time: 2015-12-17 08:33:11 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CFIR-08252015-744 Report Generated at: 2015-12-17 08:11:33
CERTI f E OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE OD
Project ame: New Residence Ca culation Date/Time: 08:10, Thu, Dec 17, 2015
Calculation Description: Title 24 Analysis
Input File Name: Hideaway Lot 48-51 -Stracts-1 5.xml
C FORF-01
Page 4 of 13
ATTIC
01
02
03
04
05
06
07
08
Name
Construction
Type
Roof Rise
Roof Reflectance
Roof Emittance
Radiant Barrier
Cool Roof
Attic master Zone
Attic Roofmaster Zone
Ventilated
3
0.1
0.85
No
No
Attic grt din kit zone
Attic Roofgrt din kit zone
Ventilated
3
0.1
0.85
No
No
Attic bed
Attic Roofbed
Ventilated
3
0.1
0.85
No
No
Attic casita zone
Attic Roofcasita zone
Ventilated
3
0.1
0.85
No
No
La" CERTS, nc,
Registration Number: 215-N630540OB-000000000-0000 Registration Date/Time: 2015-12-17 08:33:11 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-08252015-744 Report Generated at: 2015-12-17 08:11:33
CERTIVE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE OD
Project ame: New Residence Ca culation Date/Time: 08:10, Thu, Dec 17, 2015
Calculation Description: Title 24 Analysis
Input File Name: Hideaway Lot 48-51-Stracts-15.xm1
CRF -01
Page 5 of 13
WINDOWS
01
02
03
04
05
06
07
08
09
10
Name
Type
Surface (Orientation -Azimuth)
Width (ft) Height (ft)
Multipli
er
Area
(ft2)
U -factor
SHGC
Exterior Shading
K
Window
NE Wall (Right -45)
--
---
1
6.0
0.32
0.29
Insect Screen (default)
8
Window
NE Wall (Right -45)
---
---
1
1 96.0
0.32 1
0.29
Insect Screen (default)
9
Window
SE Wall (Front -135)
14.0
8.0
1
112.0
0.32
0.29
Insect Screen (default)
11
Window
SW Wall (left -225)
7.5
10.0
1
75.0
0.32
0.29
Insect Screen (default)
10
Window
NW Wall (Back -315)
12.0
10.0
1
120.0
0.32
0.29
Insect Screen (default)
O
Window
NW Wall (Back -315)
-
-
1
6.0
0.32
0.29
Insect Screen (default)
P
Window
NW Wall (Back -315)
---
-
1
10.0
0.32
0.29
Insect Screen (default)
N
Window
NW Wall (Back -315)
---
---
1
8.0
0.32
0.29
Insect Screen (default)
M
Window
NW Wall (Back -315)
-
----
1
10.0
0.32
0.29
Insect Screen (default)
L
Window
NW Wall (Back -315)
--
---
1
6.0
0.32
0.29
Insect Screen (default)
F
Window
SE Wall 2 (Front -135)
---
---
1
7.1
1 0.32
0.29
Insect Screen (default)
2
Window
SE Wall 2 (Front -135) r !� . t - 12.0 8.0
1
96.0
0.32
0.29
Insect Screen (default)
E
Window
SE Wall 2 (Front -135)
19.0�.t
11.0 j
i1�`1 f
X209.0
0.32
0.29
Insect Screen (default)
C
Window
\ SE Wall 2 (Front 135) ti`s_ i ., u
� 4.0
r. �� 8.0
' 1 [) j. x_32.0
0.32
0.29
Insect Screen (default)
B
Window
SE Wall 2,(Front-135)-) <
P 4.01
, 8.0 y 11#
X32.0
0.32
0.29
Insect Screen (default)
A
Window
SE Wall 2 (Front -135)
8.8
12.3
1
108.2
0.32
0.29
Insect Screen (default)
1
Window
SE Wall 2 (Front -135)
4.0
10.0
1
40.0
0.32
0.29
Insect Screen (default)
16
Window
SW Wall 2 (Left -225)
27.5
10.0
1
275.0
0.32
0.29
Insect Screen (default)
13
Window
SW Wall 2 (Left -225)
7.5
10.0
1
75.0
0.32
0.29
Insect Screen (default)
D
Window
SW Wall 2 (Left -225)
---
---
1
36.0
0.32
0.29
Insect Screen (default)
T
Window
NW Wall 2 (Back -315)
12.0
12.0
1
144.0
0.32
0.29
Insect Screen (default)
S
Window
NW Wall 2 (Back -315)
4.0
8.0
1
32.0
0.32
0.29
Insect Screen (default)
R
Window
NW Wall 2 (Back -315)
4.0
8.0
1
32.0
0.32
0.29
Insect Screen (default)
15
Window
NW Wall 2 (Back -315)
8.6
10.0
1
86.0
0.32
0.29
Insect Screen (default)
14
Window
NW Wall 2 (Back -315)
3.0
8.0
1
24.0
0.32
0.29
Insect Screen (default)
12
Window
NW Wall 2 (Back -315)
12.5
10.0
1
125.0
0.32
0.29
Insect Screen (default)
19
Window
NE Wall 3 (Right -45)
---
----
1
72.0
0.32
0.29
Insect Screen (default)
Z
Window
SE Wall 3 (Front -135)
-
-
1
30.0
0.32
0.29
Insect Screen (default)
Y
Window
SE Wall 3 (Front -135)
-
- -
1
6.0
0.32
0.29
Insect Screen (default)
Registration Number: 215-N630540OB-000000000-0000 Registration Date/Time: 2015-12-17 08:33:11 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-08252015-744 Report Generated at: 2015-12-17 08:11:33
CERTI�E OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE �OD
Project ame: New Residence Ca culation Date/Time: 08:10, Thu, Dec 17, 2015
Calculation Description: Title 24 Analysis
Input File Name: Hideaway Lot 48-51-Stracts-15.xm1
CF*RF-01
Page 6 of 13
x
Window
SE Wall 3 (Front -135)
- --
1
6.0
0.32
0.29
Insect Screen (default)
W
Window
SW Wall 3 (Left -225)
--- ----
1
4.0
0.32
0.29
Insect Screen (default)
V
Window
SW Wall 3 (Left -225)
--- ---
1
12.5
0.32
0.29
Insect Screen (default)
U
Window
SW Wall 3 (Left -225)
--- ---
1
12.5
0.32
0.29
Insect Screen (default)
18
Window
NW Wall 3 (Back -315)
11.0 8.0
1
88.0
0.32
0.29
Insect Screen (default)
17
Window
NW Wall 3 (Back -315)
6.0 8.0
1
48.0
0.32
0.29
Insect Screen (default)
EE
Window
NE Wall 4 (Right -45)
--- ---
1
6.0
0.32
0.29
Insect Screen (default)
DD
Window
NE Wall 4 (Right -45)
-- ---
1
6.0
0.32
0.29
Insect Screen (default)
Cc
Window
NE Wall 4 (Right -45)
-- ---
1
6.0
0.32
0.29
Insect Screen (default)
42
Window
NE Wall 4 (Right -45)
-- ---
1
68.0
0.32
0.29
Insect Screen (default)
BB
Window
SE Wall 4 (Front -135)
- ---
1
6.0
0.32
0.29
Insect Screen (default)
AA
Window
SE Wall 4 (Front -135)
--- ---
1
15.0
0.32
0.29
Insect Screen (default)
HH
Window
SE Wall 4 (Front -135)
--- --
1
6.0
0.32
0.29
Insect Screen (default)
KK
Window
SW Wall 4 (Left -225)
-- ---
1
15.0
0.32
0.29
Insect Screen (default)
JJ
Window
SW Wall 4 (Left -225)
--- ---
1
15.0
0.32
0.29
Insect Screen (default)
LL
Window
SW Wall 4 (Left -225) tr' I T ZIN
C- §'.14 ---
1
6.0
0.32
0.29
Insect Screen (default)
GG
Window
SW Wall 4 (17eft-225) 541!�
- ---
; r 1)J
-6.0
0.32
0.29
Insect Screen (default)
FF
WindowSW
Wall_4,(L`eft-225) �# ) �- ij
-' ` '-'
ee -U
1 6:0
0.32
0.29
Insect Screen (default)
44
Window
',,�NW Wall 4J(Back-315)'� ?
'" ` ' m
]t 1 :
68.0
0.32
0.29
Insect Screen (default)
43
Window
NW Wall 4 (Back -315)
--- ----
1
68.0
0.32
0.29
Insect Screen (default)
DOORS
01 02 03 04
Name Side of Building Area (ft2) U -factor
23 NE Wall 2 24.0 0.50
Registration Number: 215-N6305400B-000000000-0000 Registration Date/Time: 2015-12-17 08:33:11 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-08252015-744 Report Generated at: 2015-12-17 08:11:33
CERTIFOE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE *OD
Project ame: New Residence Ca culation Date/Time: 08:10, Thu, Dec 17, 2015
Calculation Description: Title 24 Analysis
Input File Name: Hideaway Lot 48-51-Stracts-15.xmi
CF*RF-01
Page 7 of 13
OVERHANGS AND FINS
01
02
03
04
05
06
07
08 09
10
11
12
13
14
Overhang
Left Fin
Right Fin
Window
Depth
Dist Up
Left
Extent
Right
Extent
Flap Ht.
Depth
Top Up DistL
Bot Up
Depth
Top Up Dist R
Bot Up
9
10
0.1
10
10
0
0
0 0
0
0
0
0
0
11
14
0.1
14
14
0
0
0 0
0
0
0
0
0
10
10
0.1
10
10
0
0
0 0
0
0
0
0
0
2
14
0.1
14
14
0
0
0 0
0
0
0
0
0
E
14
0.1
14
14
0
0
0 0
0
0
0
0
0
C
14
0.1
14
14
0
0
0 0
0
0
0
0
0
B
14
0.1
14
14
0
0
0 0
0
0
0
0
0
A
14
0.1
14
14
0
0
0 0
0
0
0
0
0
1
14
0.1
14
14
0
0
0 0
0
0
0
0
0
16
20
0.1
20
20
0
0
0 0
0
0
0
0
0
13
20
0.1
--30
i'1 20 =, � 0� -.' �_.. 0� �
On 0
0
0
0
0
0
T
14
-4 0.1
14'`�
� X14
a 0. )
f~0 -.�
01 0
0
0
0
0
0
S
14
< _\*0.1
1 _14
i# X14,-_�
i�0 € 11
11 0
011 if 11 Q"
0
0
0
0
0
R
14
041
X14 3=
m14,c
r0, n
'I-,% i� Oro
0
0
0
0
0
15
14
0'1
14 '"-I
'14'
� 0 `
" `0 `
0" ~ — 0' `
0
0
0
0
0
14
14
0.1
14
14
0
0
0 0
0
0
0
0
0
12
14
0.1
14
14
0
0
0 0
0
0
0
0
0
18
10
0.1
10
10
0
0
0 0
0 4
00
0
0
17
10
0.1
10
10
0
0
0 0
0
0
0
0
0
Registration Number: 215-N6305400B-000000000-0000 Registration Date/Time: 2015-12-17 08:33:11 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-08252015-744 Report Generated at: 2015-12-17 08:11:33
CERTIFPE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE *OD
Project ame: New Residence Ca culation DatefTime: 08:10, Thu, Dec 17, 2015
Calculation Description: Title 24 Analysis Input File Name: Hideaway Lot 48-51-Stracts-15.xml
CF*RF-01
Page 8of13
OPAQUE SURFACE CONSTRUCTIONS
01
02
03
04
05
06
07
02
03
04
05
Total Cavity
Winter Design
Name
Construction Name
Surface Type
Construction Type
Framing
R -value
U -value
Assembly Layers
master Zone
1586
140
None
0.8
No
• Cavity/ Frame: no insul. / 2x4 Top Chrd
grt din kit zone
3134
186
2x4 Top Chord of Roof Truss @ 24
0.8
No
Roof Deck: Wood Siding/sheathing/decking
Attic Roofmaster Zone
Attic Roofs
Wood Framed Ceiling
in. O.C.
none
0.644
Roofing: Light Roof (Asphalt Shingle)
casita zone
1163
155
None
0.8
No
• Inside Finish: Gypsum Board
Ceilings (below
Cavity/Frame: R-9.1 /2x4
R-38 Roof(R.38.2x14.16)
attic)
Wood Framed Ceiling
2x4 @ 16 in. O.C.
R 38
0.025
Over Floor Joists: R-28.9 insul.
• Inside Finish: Gypsum Board
• Cavity / Frame: R-21 / 2x6
• Exterior Finish: Wood
R-21 Wall (W.19.2x6.16)
Exterior Walls
Wood Framed Wall
2x6 @ 16 in. O.C.
R 21
0.066
Siding/sheathing/decking
• Cavity/ Frame: no insul. / 2x4 Top Chrd
2x4 Top Chord of Roof Truss @ 24
Roof Deck: Wood Siding/sheathing/decking
Attic Roofgrt din kit zone
Attic Roofs
Wood Framed Ceiling
in. O.C.
none
0.644
Roofing: Light Roof (Asphalt Shingle)
• Cavity/ Frame: no insul. / 2x4 Top Chrd
2x4 Top Chord of Roof Truss @ 24
Roof Deck: Wood Siding/sheathing/decking
Attic Roofbed
Attic Roofs
Wood Framed Ceiling
j5,^ rinr0.97�-.
none,1
0.644
Roofing: Light Roof (Asphalt Shingle)
}
2x4kTop Chord of Roof Truss 24
'�
f
f "
- Cavity / Frame: no insul. / 2x4 Top Chrd
Roof Deck: Wood Siding/sheathing/decking
Attic Roofcasita zone
Attic Roofs
Wood Framed Ceiling
t.l _ L e3 i.
in^O.C:
�]
.1 Tr LLL
Vnone
0.644'
Roofing: Light Roof (Asphalt Shingle)
a► 9-4 r s -c `. s.I O -e t I tr it a a r- 9�q
SLAB FLOORS
01
02
03
04
05
06
07
Name
Zone
Area (ft)
Perimeter (ft)
Edge Insul. R -value & Depth
Carpeted Fraction
Heated
Slab
master Zone
1586
140
None
0.8
No
Slab 2
grt din kit zone
3134
186
None
0.8
No
Slab 3
bed
722
125
None
0.8
No
Slab 4
casita zone
1163
155
None
0.8
No
BUILDING ENVELOPE - HERS VERIFICATION
01 02 03 04
Quality Insulation Installation (QII) Quality Installation of Spray Foam Insulation Building Envelope Air Leakage CFM50
Not Required Not Required Required 4359.3
Registration Number: 215-N6305400B-000000000-0000 Registration Date/Time: 2015-12-17 08:33:11 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-08252015-744 Report Generated at: 2015-12-17 08:11:33
CERTIFJOE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE *OD
Project ame: New Residence Ca culation Date/Time: 08:10, Thu, Dec 17, 2015
Calculation Description: Title 24 Analysis
Input File Name: Hideaway Lot 48-51 -Stracts-1 5.xml
CF*RF-01
Page 9of13
WATER HEATING SYSTEMS
01
02
03
04
05
01
02
03
04
05
06
Name
System Type
Distribution Type
Water Heater
Number of Heaters
Solar Fraction (%)
DHW Sys 1 - 1/2
DHW
Pipe Insulation, All Lines
DHW Heater 1
2
.0%
DHW Sys 3 - 1/1
DHW
Pipe Insulation, All Lines
DHW Heater 3
1
.0%
WATER HEATERS
01
02
03
04
05
06
07
08
Name
Heater Element Type
Tank Type
Tank Volume
(gal)
Energy Factor or
Efficiency
Input Rating
Tank Exterior
Insulation
R -value
Standby Loss
(Fraction)
DHW Heater 1
Natural Gas
Small Storage
75
0.65
65000-Btu/hr
0
0
DHW Heater 3
Natural Gas
Small Storage
50
0.62
40000-Btu/hr
0
0
WATER HEATING - HERS VERIFICATION
01
02 , _
r, 03,
j04j
05
06
07
Name
Pipe Insulation
f Parallel Piping
Compact Distribution
`Point -of Use
Recirculation
Control
Central DHW
Distribution
DHW Sys 1 1/2
.�; ;+.:�
�.�.` ti: -r t_ i u
f i+_f 'r V
System
DHW Sys 3 - 1/1
---
.� � t- rll
v, t U
t, t"" --
Heating Component 2
Cooling Component 2
SPACE CONDITIONING SYSTEMS
01
02
03
04
05
06
SC Sys Name
System Type
Heating Unit Name
Cooling Unit Name
Fan Name
Distribution Name
HVAC 11
Other Heating and Cooling
Heating Component 1
Cooling Component 1'
HVAC Fan 1
Air Distribution System 1
System
HVAC 2,32
Other Heating and Cooling
Heating Component 2
Cooling Component 2
HVAC Fan 2
Air Distribution System 2
System
HVAC 43
Other Heating and Cooling
Heating Component 3
Cooling Component 3
HVAC Fan 3
Air Distribution System 3
System
HVAC 54
Other Heating and Cooling
Heating Component 4
Cooling Component 4
HVAC Fan 4
Air Distribution System 4
System
Registration Number: 215-N6305400B-000000000-0000 Registration Date/Time: 2015-12-17 08:33:11 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF113-08252015-744 Report Generated at: 2015-12-17 08:11:33
CERTI f E OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE *OD
Project ame: New Residence Ca culation Date/Time: 08:10, Thu, Dec 17, 2015
Calculation Description: Title 24 Analysis Input File Name: Hideaway Lot 48-51 -Stracts-1 5.xml
CF•RF-01
Page 10 of 13
HVAC - HEATING UNIT TYPES
01
02
01
02
03
Name
Type
Efficiency
Heating Component 1
CntrlFurnace - Fuel -fired central furnace
80 AFUE
Heating Component 2
CntrlFurnace - Fuel -fired central furnace
80 AFUE
Heating Component 3
CntrlFurnace - Fuel -fired central furnace
80 AFUE
Heating Component 4
CntrlFurnace - Fuel -fired central furnace
80 AFUE
HVAC - COOLING UNIT TYPES
01
02
03 04
05
06
07
Name
Verified Airflow
Efficiency
Verified EER
Multi -speed
Verified Refrigerant
Charge
Name
System Type
EER SEER
Zonally Controlled
Compressor
HERS Verification
Cooling Component 1
SplitAirCond
13
16
Not Zonal
Single Speed
Cooling Component
1 -hers -cool
Cooling Component 2
SplitAirCond
13
16
Not Zonal
Single Speed
Cooling Component
1 -hers -cool
Cooling Component 3
SplitAirCond
{
} 13 �
;16
Zonally, Controlled
Single Speed
Cooling Component
1
.t tt
liF jI
_�!
F I? t1 /!�
-hers -cool
Cooling Component 4
SplitAi Cond\ �'
x 13� �
�
fp y�_
x L1 t116
N 3i ,�
N1 (I nal {
Single Speed
g p
Cooling Component
'N_
1 -hers -cool
HVAC COOLING - HERS VERIFICATION
01
02
03
04
05
06
Name
Verified Airflow
Airflow Target
Verified EER
Verified SEER
Verified Refrigerant
Charge
Cooling Component 1 -hers -cool
Required
350
Required
Required
Required
Cooling Component 2 -hers -cool
Required
350
Required
Required
Required
Cooling Component 3 -hers -cool
Required
150
Required
Required
Required
Cooling Component 4 -hers -cool
Required
350
Required
Required
Required
Registration Number: 215-N6305400B-000000000-0000 Registration Date/Time: 2015-12-17 08:33:11 HERS Provider: CaIGERTS inc.
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-08252015-744 Report Generated at: 2015-12-17 08:11:33
CERTIFf E OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE *OD
Project ame: New Residence Ca culation Date/Time: 08:10, Thu, Dec 17, 2015
Calculation Description: Title 24 Analysis Input File Name: Hideaway Lot 48-51-Stracts-15.xml
CF*RF-01
Page 11 of 13
HVAC - DISTRIBUTION SYSTEMS
01
02
03
04
05
06
07
Name
Type
Duct Leakage
Insulation R -value
Duct Location
Bypass Duct
HERS Verification
Air Distribution System 1
LowLlCod
Sealed and tested
8
Conditioned zone (VLL)
None
Air Distribution System
1 -hers -dist
Air Distribution System 2
Lowl-lCod
Sealed and tested
8
Conditioned zone (VLL)
None
Air Distribution System
2 -hers -dist
Air Distribution System 3
LowLlCod
Sealed and tested
8
Conditioned zone (VLL)
None
Air Distribution System
3 -hers -dist
Air Distribution System 4
LowLlCod
Sealed and tested
8
Conditioned zone (VLL)
None
Air Distribution System
4 -hers -dist
HVAC DISTRIBUTION - HERS VERIFICATION
01
02
03
04
05
06
07
08
Name
Duct Leakage
Verification
Duct Leakage
Target (%)
Verified Duct
Location
Verified Duct
Design
Buried
Ducts
Deeply Buried
Ducts
Low -leakage
Air Handler
Air Distribution System 1 -hers -dist
Required
6.0
Required
Not Required
Not Required
Not Required
—
Air Distribution System 2 -hers -dist
Required �`
X6.0: �' _
J , _Required '
[ Not Required ,
: Not Required
Not Required
Air Distribution System 3 -hers -dist
Required V11
rr � 1I >*'i
I Required
NotyRequired
i Not Required
Not Required
--
Air Distribution System 4 -hers -dist
Required
6.0
Required
Not Required
Not Required
Not Required
---
v r■ e rti _ z r' F z a r u r z� z ■ z
HVAC -FAN SYSTEMS
01
01
02
03
04
Name
Type
Fan Power (Watts/CFM)
HERS Verification
HVAC Fan 1
Single Speed PSC Furnace Fan
0.58
HVAC Fan 1 -hers -fan
HVAC Fan 2
Single Speed PSC Furnace Fan
0.58
HVAC Fan 2 -hers -fan
HVAC Fan 3
Single Speed PSC Furnace Fan
0.58
HVAC Fan 3 -hers -fan
HVAC Fan 4
Single Speed PSC Furnace Fan
0.58
HVAC Fan 4 -hers -fan
HVAC FAN SYSTEMS - HERS VERIFICATION
01
02
03
Name
Verified Fan Watt Draw
Required Fan Efficiency (Watts/CFM)
HVAC Fan 1 -hers -fan
Required
0.58
HVAC Fan 2 -hers -fan
Required
0.58
HVAC Fan 3 -hers -fan
Required
0.58
Registration Number: 215-N6305400B-000000000-0000 Registration Date/Time: 2015-12-17 08:33:11 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-08252015-744 Report Generated at: 2015-12-17 08:11:33
CERTI'PE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE WOD
Project ame: New Residence ation Date/Time: 08:10, Thu, Dec 17, 2015
Calculation Description: Title 24 Analysis Input File Name: Hideaway Lot 48-51 -Stracts-1 5.xmi
HVAC Fan 4 -hers -fan Required 0.58
C*RF-01
Page 12 of 13
IAQ (Indoor Air Quality) FANS
01
02
03
04
05
06
Dwelling Unit
IAQ CFM
IAQ Watts/CFM
IAQ Fan Type
IAQ Recovery
Effectiveness(%)
HERS Verification
SFam IAQVentRpt
111.05
0.25
Default
0
Required
PROJECT NOTES
Mountian West Investments
Joint Venture with Sedona Homes/Sunrose corp.
The Hideaway County Club
CERI , mc.
H ERS PROVIDER
Registration Number: 215-N6305400B-000000000-0000 Registration Date/Time: 2015-12-17 08:33:11 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-08252015-744 Report Generated at: 2015-12-17 08:11:33
CERTI %E OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE OD
Project ame: New Residence Ca culation Date/Time: 08:10, Thu, Dec 17, 2015
Calculation Description: Title 24 Analysis
Input File Name: Hideaway Lot 48-51-Stracts-15.xm1
C19RF-01
Page 13 of 13
DOCUMENTATION AUTHOR'S DECLARATION STATEMENT
1. 1 certify that this Certificate of Compliance documentation is accurate and complete.
Documentation Author Name:
Documentation Author Signature:
T&W11.157alEr
Tim Scott
Company:
Signature Date:
Scott Design and Title 24, Inc.
2015-12-17 08:33:11
Address:
CEA/HERS Certification Identification (If applicable):
77085 Michigan Drive
City/State/Zip:
Phone:
Palm Desert, CA 92211
760-200-4780
RESPONSIBLE PERSON'S DECLARATION STATEMENT
I certify the following under penalty of perjury, under the laws of the State of California:
1. 1 am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design identified on this Certificate of Compliance.
2. 1 certify that the energy features and performance specifications identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of
Regulations.
3. The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents,
worksheets, calculations, plans and specifications submitted to,the enforcement agency for approval with.this building permit application.
Responsible Designer Name:'_.
_� j
Responsible Designer Signature:"
Tu�ri.Sea i
1� C
Tim Scott _
---x
-,-,
-- � rt t1,
Company:HERt�
"�
Date,Signed: JWl^�
201542-1708:33:1-1
Scott Design and Title 24, Inc.
Address:
License:
77085 Michigan Drive
na
City/State/Zip:
Phone:
Palm Desert, CA 92211
760-200-4780
Digitally signed by CaICERTS. This digital signature is provided in order to secure the content of this registered document, and in noway implies Registration Provider responsibility for the accuracy of the
information.
Registration Number: 215-N6305400B-000000000-0000 Registration Date/Time: 2015-12-17 08:33:11 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-08252015-744 Report Generated at: 2015-12-17 08:11:33
•
RESIDENTIAL MEASURES SUMMARY
RMS -1
Project Name
A New Residence
Building Type 10 Single Family ❑ Addition Alone
❑ Multi Family ❑ Existing+ Addition/Alteration
Date
12/17/2015
Project Address
Lots 48-51, The Hideaway
La Quinta
California Energy Climate Zone
CA Climate Zone 15
Total Cond. Floor Area
6,605
Addition
n/a
# of Units
1
INSULATION
Construction Type
Area
Cavity ftz Special Features Status
Roof Wood Framed Attic
R38 6,605
New
Wall Wood Framed
R 21 12,803
New
Slab Unheated Slab -on -Grade
- no insulation 6,605 Perim = 606'
New
Demising Wood Framed
- no insulation 2,467
New
Door Opaque Door
- no insulation 24
New
FENESTRATION
Orientation Area ft
T Total Area: 2.378 Glazin Percentage: 6.0%1
U -Fac SHGC Overhang Sidefins
New/Altered Average U -Factor: 0.32
Exterior Shades Status
Right (NE) 260.0
0.320
0.29 none none
Bug Screen New
Front (SE) 112.0
0.320
0.29 10.0 none
Bug Screen New
Left (SW) 75.0
0.320
0.29 14.0 none
Bug Screen New
Rear (NIA) 256.0
0.320
0.29 10.0 none
Bug Screen New
Rear (Nw) 176.0
0.320
0.29 none none
Bug Screen New
Front (SE) 76.1
0.320
0.29 none none
Bug Screen New
Front (SE) 517.2
0.320
0.29 14.0 none
Bug Screen New
Left (SW) 350.0
Left (SW) 113.0
0.320
0.320
0.29 20.0 none
0.29 none none
Bug Screen New
Bug Screen New
Rear (NW) 443.0
0.320
0.29 14.0 none
Bug Screen New
HVAC SYSTEMS
Qty. Heating
Min. Eff
Cooling Min. Eff
Thermostat Status
1 Central Furnace
80% AFUE
Split Air Conditioner 16.0 SEER
Setback
New
2 Central Furnace
80% AFUE
Split Air Conditioner 16.0 SEER
Setback
New
1 Central Furnace
80% AFUE
Split Air Conditioner 16.0 SEER
Setback
New
HVAC DISTRIBUTION
Location Heating
Cooling Duct Location
Duct
R -Value Status
HVAC 1 Ducted
Ducted Conditioned
8.0
New
HVAC 2,3 Ducted
Ducted Conditioned
8.0
New
HVAC 4 Ducted
Ducted Conditioned
8.0
New
WATER HEATING
Qty. Type
Gallons Min. Eff Distribution Status
2 Small Storage Gas
75
0.65 All Pipes Ins
New
1 Small Storage Gas
50
0.62 All Pipes Ins
New
EnerqyPro 6.7 by EnerqySoft User Number: 6712
RunCode: 2015-12-17T08:11:52
/D:
Pae 16 of 40
•
•
•
RESIDENTIAL MEASURES SUMMARY
RMS -1
Project Name
A New Residence
Building Type m Single Family ❑ Addition Alone
❑ Multi Family ❑ Existing+ Addition/Alteration
Date
11211712015
Project Address
Lots 48-51, The Hideaway
La Quinta
California Energy Climate Zone
CA Climate Zone 15
Total Cond. Floor Area
6,605
Addition
n/a
# of Units
1
INSULATION
Construction Type
Area
Cavity ftz Special Features
Status
FENESTRATION
Orientation Area(ft2)
I Total Area: 2,378 Glazin Percentage: 36.0 % I New/Altered Average U -Factor:
U -Fac SHGC Overhang Sidefins Exterior Shades
0.32
Status
HVAC SYSTEMS
Qty. Heating
Min. Eff Cooling Min. Eff Thermostat
Status
1 Central Furnace
80% AFUE Split Air Conditioner 16.0 SEER Setback
New
HVAC DISTRIBUTION Duct
Location Heating Cooling Duct Location R -Value
Status
HVAC 5 Ducted
Ducted Conditioned 8.0
New
WATER HEATING
Qty. Type
Gallons Min. Eff Distribution
Status
Ene Pro 6.7 by EnerqySoft User Number: 6712 Run Code: 2015-12-17708:11:52 /D:
Pae 17 of 40
F'__
41
2013 Low -Rise Residential Mandatory Measures Summary
NOTE: Low-rise residential buildings subject to the Standards must comply with all applicable mandatory measures listed, regardless of the
COmD1lanCe anDroach used. Excentions may annly. Review the rp-mPrtivo rndo cortinn Ar mnro inArmntinn
Building Envelope Measures:
§I 10.6(a)1:
Doors and windows between conditioned and unconditioned spaces are manufactured to limit air leakage.
§1 10.6(a)5:
Fenestration products (except field -fabricated windows) have a label listing the certified U -Factor, certified Solar Heat Gain
Coefficient SHGC and infiltration that meets the requirements of 10-111 a .
§110.7:
Exterior doors and windows are weatherstripped; all joints and penetrations are caulked and sealed.
§I 10.8(a):
Insulation specified or installed meets Standards for Insulating Material. Indicate type and include on the CF2R.
§ 110.8(i):
The thermal emittance and aged solar reflectance values of the cool roofing material meets the requirements of § 1 10.8(i) when the
installation of a cool roof is specified on the CFI R.
§ 110.80):
A radiant barrier shall have an emittance of 0.05 or less when the installation of a radiant barrier is specified on the CFI R.
Minimum R-30 insulation in wood -frame ceiling; or the weighted average U -factor shall not exceed 0.031. Minimum R-19 in a
§ 150.0(a):
rafter roof alteration. Attic access doors shall have permanently attached insulation using adhesive or mechanical fasteners. The
attic access shall be gasketed to prevent air leakage.
§I50.0(b):
Loose fill insulation shall conform with manufacturer's installed design labeled R -value.
§ 150.0(c):
Minimum R-13 insulation in 2x4 inch wood framing wall or have a U -factor of 0.102 or less (R-19 in 2x6 or 0.074 maximum U -
factor).
§ I50.0(d):
Minimum R-19 insulation in raised wood -frame floor or 0.037 maximum U -factor.
In Climate Zones 14 and 16 a Class II vapor retarder shall be installed on the conditioned space side of all insulation in all exterior
§I50.0(g)1:
walls, vented attics and unvented attics with air -permeable insulation.
In Climate Zones 1-16 with unvented crawl spaces the earth floor of the crawl space shall be covered with a Class i or Class 11
§ 150.0(g)2:
vapor retarder.
In a building having a controlled ventilation crawl space, a Class I or Class 11 vapor retarder shall be placed over the earth floor of
§ I50.0(g)3:
the crawl space to reduce moisture entry and protect insulation from condensation, as specified in the exception to Section
150.0(d).
§ 150.0(1):
Slab edge insulation shall: have a water absorption rate, for the insulation material alone without facings, no greater than 0.3%;
have water vapor permeance rate is no greater than 2.0 perm/inch, be protected from physical damage and UV light deterioration;
and when installed as part of a heated slab floor meets the requirements of § 110.8
150.0
§ (q)'
Fenestration, including skylights, separating conditioned space from unconditioned space or outdoors shall have a maximum U-
factor of 0.58; or the weighted average U -factor of all fenestration shall not exceed 0.58.
Fireplaces, Decorative Gas Appliances and Gas Log Measures:
§I50.0(e)IA:
Masonry or factory -built fireplaces have a closable metal or glass door covering the entire opening of the firebox.
§I50.0(e)IB:
Masonry or factory -built fireplaces have a combustion outside air intake, which is at least six square inches in area and is
equipped with a readily accessible, operable, and tight -fitting damper or a combustion -air control device.
§I50.0(e)IC:
Masonry or factory -built fireplaces have a flue damper with a readily accessible control.
§I50.0(e)2:
Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the outside
of the building, are prohibited.
Space Conditioning, Water Heating and Plumbing System Measures:
§110.0-§110.3:
HVAC equipment, water heaters, showerheads, faucets and all other regulated appliances are certified to the Energy Commission.
§ 110.3(c)5:
Water heating recirculation loops serving multiple dwelling units meet the air release valve, backflow prevention, pump isolation
valve, and recirculation loop connection requirements of § 110.3(c)5.
Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces, household cooking appliances (appli-
§ 110.5:
ances without an electrical supply voltage connection with pilot lights that consume less than 150 Btu/hr are exempt), and pool
ands a heaters.
§I50.0(h)1:
Heating and/or cooling loads are calculated in accordance with ASHRAE, SMACNA or ACCA using design conditions specified
in§150.Oh2.
§I50.0(h)3A:
Installed air conditioner and heat pump outdoor condensing units shall have a clearance of at least five feet from the outlet of any
dryer vent.
§I50.0(i):
Heating systems are equipped with thermostats that meet the setback requirements of §I I0.2(c).
§150.00)1A:
Storage gas water heaters with an energy factor equal to or less than the federal minimum standards shall be externally wrapped
with insulation having an installed thermal resistance of R-12 or greater.
§150.00)1B:
Unfired hot water tanks, such as storage tanks and backup storage tanks for solar water -heating systems, have R-12 external
insulation or R-16 internal insulation where the internal insulation R -value is indicated on the exterior of the tank.
For domestic hot water system piping, whether buried or unburied: the first 5 feet of hot and cold water pipes from the storage
tank, all piping with a nominal diameter of 3/4 inch or larger, all piping associated with a domestic hot water recirculation system
§ 150.00)2A:
regardless of the pipe diameter, piping from the heating source to storage tank or between tanks, piping buried below grade, and
all hot water pipes from the heating source to kitchen fixtures must be insulated according to the requirements of TABLE 120.3-
A.
§150.00)2B:
All domestic hot water pipes that are buried below grade must be installed in a water proof and non -crushable casing or sleeve
that allows for installation, removal, and replacement of the enclosed pipe and insulation.
is
2013 Low -Rise Residential Mandatory Measures Summary
§ I50.00)2C:
Pipe for cooling system lines shall be insulated as specified in § I50.00)2A. Piping insulation for steam and hydronic heating
systems or hot waters stems with pressure > 15 psig shall meet the requirements in TABLE 120.3-A.
§150.00)3:
Insulation is protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind.
Insulation exposed to weather shall either be rated for outdoor use or installed with a cover suitable for outdoor service. For
§ I50.00)3A:
example, protected by aluminum, sheet metal, painted canvas, or plastic cover. Cellular foam insulation protected as specified or
painted with coating that is water retardant and provides shielding from solar radiation that degrades the material.
Insulation covering chilled water piping and refrigerant suction piping located outside the conditioned space shall have a Class I
§150.00)3B:
or Class II vapor retarding facing, or the insulation shall be installed at the thickness that qualifies as a Class 1 or Class It vapor
retarder.
Systems using gas or propane water heaters to serve individual dwelling units shall include: a 120V electrical receptacle within 3
feet of the water heater; a Category III or IV vent, or a Type B vent with straight pipe between the outside termination and the
§150.0(n)l:
space where the water heater is installed; a condensate drain that is no more than 2 inches higher than the base of the installed
water heater, and allows natural draining without pump assistance; and a gas supply line with a capacity of at least 200,000
Btu/hr.
§I50.0(n)2:
Recirculating loops serving multiple dwelling units shall meet the requirements of §I 10.3(c)5.
§I50.0(n)3:
Solar water -heating systems and collectors shall be certified and rated by the Solar Rating and Certification Corporation (SRCC)
or by a testing agency approved by the Executive Director.
Ducts and Fans Measures:
All air -distribution system ducts and plenums installed are sealed and insulated to meet the requirements of CMC §601.0, §602.0,
§603.0, §604.0, §605.0 and ANSI/SMACNA-006-2006 HVAC Duct Construction Standards Metal and Flexible 3rd Edition.
Supply -air and return -air ducts and plenums are insulated to a minimum installed level of R-6.0 (or higher if required by CMC
§605.0) or enclosed entirely in directly conditioned space as confirmed through field verification and diagnostic testing
(RA3.1.4.3.8). Connections of metal ducts and inner core of flexible ducts are mechanically fastened. Openings shall be sealed
§I50.0(m)l:
with mastic, tape, or other duct -closure system that meets the applicable requirements of UL 181, UL 181A, or UL 181 B or
aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings greater than '/4 inch, the
combination of mastic and either mesh or tape shall be used. Building cavities, support platforms for air handlers, and plenums
defined or constructed with materials other than sealed sheet metal, duct board or flexible duct shall not be used for conveying
conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms
shall not be compressed to cause reductions in the cross-sectional area of the ducts.
Factory -Fabricated Duct Systems shall comply with specified requirements for duct construction, connections, and closures; joints
§I50.0(m)2:
and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such tape is
used in combination with mastic and draw bands.
§I50.0(m)3-6:
Field -Fabricated Duct Systems shall comply with requirements for: pressure -sensitive tapes, mastics, sealants, and other
requirements specified for duct construction; duct insulation R -value ratings; duct insulation thickness; and duct labeling.
§ I50.0(m)7:
All fan systems that exchange air between the conditioned space and the outside of the building must have backdraft or automatic
dampers.
§ I50.0(m)8:
Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated dampers
except combustion inlet and outlet air openings and elevator shaft vents.
Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind but not
§ I50.0(m)9:
limited to the following: insulation exposed to weather shall be suitable for outdoor service. For example, protected by aluminum,
sheet metal, painted canvas, or plastic cover. Cellular foam insulation shall be protected as above or painted with a coating that is
water retardant and provides shielding from solar radiation.
§I50.0(m)10:
Flexible ducts cannot have porous inner cores.
When space conditioning systems use forced air duct systems to supply conditioned air to an occupiable space, the ducts shall be
§I50.0(m)11:
sealed and duct leakage tested, as confirmed through field verification and diagnostic testing, in accordance with Reference
Residential Appendix RA3.
Mechanical systems that supply air to an occupiable space through ductwork exceeding 10 feet in length and through a thermal
§ I50.0(m)12:
conditioning component, except evaporative coolers, shall be provided with air filter devices that meet the requirements of
§150.0 m 12.
Space conditioning systems that utilize forced air ducts to supply cooling to an occupiable space shall have a hole for the
placement of a static pressure probe (HSPP), or a permanently installed static pressure probe (PSPP) in the supply plenum. The
§I50.0(m)13:
space conditioning system must also demonstrate airflow>_ 350 CFM per ton of nominal cooling capacity through the return
grilles, and an air -handling unit fan efficacy:5 0.58 W/CFM as confirmed by field verification and diagnostic testing, in
accordance with Reference Residential Appendix RA3.
Zonally controlled central forced air cooling systems shall be capable of simultaneously delivering, in every zonal control mode,
§ I50.0(m)15:
an airflow from the dwelling, through the air handler fan and delivered to the dwelling, of >: 350 CFM per ton of nominal cooling
capacity, and operating at an air -handling unit fan efficacy of < 0.58 W/CFM as confirmed by field verification and diagnostic
testing, in accordance with Reference Residential Appendix RA3.
All dwelling units shall meet the requirements of ASHRAE Standard 62.2. Neither window operation nor continuous operation of
§ 150.0(0):
central forced air system air handlers used in central fan integrated ventilation systems are permissible methods of providing the
Whole Building Ventilation.
§150.0(o)IA:
Whole Building Ventilation airflow shall be confirmed through field verification and diagnostic testing, in accordance with
Reference Residential Appendix RA3.
Pool and Spa Heating Systems and Equipment Measures:
Any pool or spa heating system shall be certified to have: a thermal efficiency that complies with the Appliance Efficiency
§I 10.4(a):
Regulations; an on-off switch mounted outside of the heater that allows shutting off the heater without adjusting the thermostat
setting; a permanent weatherproof plate or card with operating instructions; and shall not use electric resistance heating.
4
4
2013 Low -Rise Residential Mandatory Measures Summary
§ 110.4(b)1:
Any pool or spa heating equipment shall be installed with at least 36 inches of pipe between filter and heater or dedicated suction
and return lines, or built-up connections for future solar heating.
§ 110.4(b)2:
Outdoor pools or spas that have a heat pump or gas heater shall have a cover.
§ 110.4(b)3:
Pools shall have directional inlets that adequately mix the pool water, and a time switch that will allow all pumps to be set or pro -
rammed to run only during off-peak electric demand periods.
§ 110.5:
Natural gas pool and spa heaters shall not have a continuous burning pilot light.
§I50.0(p):
Residential pool systems or equipment shall meet specified pump sizing, flow rate, piping, filters, and valve requirements.
Lighting Measures:
§ 110.9:
All lighting control devices and systems, ballasts, and luminaires shall meet the applicable requirements of § 110.9.
§ I50.0(k)IA:
Installed luminaires shall be classified as high -efficacy or low -efficacy for compliance with § 150.0(k) in accordance with TABLE
150.0-A or TABLE 150.0-B, as applicable.
§ I50.0(k)I B:
When a high efficacy and low efficacy lighting system are combined in a single luminaire, each system shall separately comply
with the applicable provisions of § 150.0(k).
The wattage and classification of permanently installed luminaires in residential kitchens shall be determined in accordance with
§ I50.0(k)l C:
§I30.0(c). In residential kitchens, the wattage of electrical boxes finished with a blank cover or where no electrical equipment has
been installed, and where the electrical box can be used for a luminaire or a surface mounted ceiling fan, shall be calculated as 180
watts of low efficacy lighting er electrical box.
§I50.0(k)ID:
Ballasts for fluorescent lamps rated 13 watts or greater shall be electronic and shall have an output frequency no less than 20 kHz.
Permanently installed night lights and night lights integral to installed luminaires or exhaust fans shall be rated to consume no
§ I50.0(k)l E:
more than 5 watts of power per luminaire or exhaust fan as determined in accordance with § I30.0(c). Night lights do not need to
be controlled by vacancy sensors.
§150.0(k)IF:
Lighting integral to exhaust fans (except when installed by the manufacturer in kitchen exhaust hoods) shall meet the applicable
requirements of § 150.0(k).
§I50.0(k)2A:
High efficacy luminaires must be switched separately from low efficacy luminaires.
§I50.0(k)2B:
Exhaust fans shall be switched separately from lighting systems.
§ I50.0(k)2C:
Luminaires shall be switched with readily accessible controls that permit the luminaires to be manually switched ON and OFF.
§I50.0(k)2D:
Controls and equipment are installed in accordance with manufacturer's instructions.
§150.0(k)2E:
No control shall bypass a dimmer or vacancy sensor function if the control is installed to comply with §I50.0(k).
§ I50.0(k)2F:
Lighting controls comply with applicable requirements of § 110.9.
An Energy Management Control System (EMCS) may be used to comply with dimmer requirements if: it functions as a dimmer
§ I50.0(k)2G:
according to § 110.9; meets Installation Certificate requirements of §130.4; the EMCS requirements of §130.5; and all other
requirements in §150.0(k)2.
An Energy Management Control System (EMCS) may be used to comply with vacancy sensor requirements of § I50.0(k) if: it
§ I50.0(k)2H:
functions as a vacancy sensor according to § 110.9; meets Installation Certificate requirements of § 130.4; the EMCS requirements
of ' 130.5; and all other requirements in § 150.0(k)2.
§I50.0(k)2I:
A multiscene programmable controller may be used to comply with dimmer requirements of this section if it provides the
functionality of a dimmer according to § 1 10.9, and complies with all other applicable requirements in §I50.0(k)2.
§ I50.0(k)3A:
A minimum of 50 percent of the total rated wattage of permanently installed lighting in kitchens shall be high efficacy.
Kitchen lighting includes all permanently installed lighting in the kitchen except internal lighting in cabinets that illuminate only
§I50.0(k)3B:
the inside of the cabinets. Lighting in areas adjacent to the kitchen, including but not limited to dining and nook areas, are
considered kitchen lighting if they are not separately switched from kitchen lighting.
§ I50.0(k)4:
Permanently installed lighting that is internal to cabinets shall use no more than 20 watts of power per linear foot of illuminated
cabinet.
§I50.0(k)5:
A minimum of one high efficacy luminaire shall be installed in each bathroom; and all other lighting installed in each bathroom
shall be high efficacy or controlled by vacancy sensors.
§ 150.0(k)6:
Lighting installed in attached and detached garages, laundry rooms, and utility rooms shall be high efficacy luminaires and
controlled by vacancy sensors.
§ 150.0(k)7:
Lighting installed in rooms or areas other than in kitchens, bathrooms, garages, laundry rooms, and utility rooms shall be high
efficacy, or shall be controlled by either dimmers or vacancy sensors.
Luminaires recessed into ceilings shall: be listed for zero clearance insulation contact (IC) by Underwriters Laboratories or other
nationally recognized testing/rating laboratory; have a label that certifies that the luminaire is airtight with air leakage less than 2.0
CFM at 75 Pascals when tested in accordance with ASTM E283; be sealed with a gasket or caulk between the luminaire housing
§150.0(k)8:
and ceiling, and shall have all air leak paths between conditioned and unconditioned spaces sealed with a gasket or caulk; and
allow ballast maintenance and replacement without requiring cutting holes in the ceiling.
For recessed compact fluorescent luminaries with ballasts to qualify as high efficacy for compliance with § I50.0(k), the ballasts
shall be certified to the Energy Commission to comply with the applicable requirements in §110.9.
For single-family residential buildings, outdoor lighting permanently mounted to a residential building or other buildings on the
same lot shall be high efficacy, or may be low efficacy if it meets all of the following requirements:
i. Controlled by a manual ON and OFF switch that does not override to ON the automatic actions of Items ii or iii below; and
§I50.0(k)9A:
ii. Controlled by a motion sensor not having an override or bypass switch that disables the motion sensor, or controlled by a
motion sensor having a temporary override switch which temporarily bypasses the motion sensing function and automatically
reactivates the motion sensor within 6 hours; and
iii. Controlled by one of the following methods:
2013 Low -Rise Residential Mandatory Measures Summary
is
a. Photocontrol not having an override or bypass switch that disables the photocontrol; or
b. Astronomical time clock not having an override or bypass switch that disables the astronomical time clock, and which is
programmed to automatically turn the outdoor lighting OFF during daylight hours; or
c. Energy management control system which meets all of the following requirements: At a minimum provides the functionality of
an astronomical time clock in accordance with §110.9; meets the Installation Certification requirements in §130.4; meets the
requirements for an EMCS in § 130.5; does not have an override or bypass switch that allows the luminaire to be always ON; and,
is programmed to automatically turn the outdoor lighting OFF during daylight hours.
For low-rise multifamily residential buildings, outdoor lighting for private patios, entrances, balconies, and porches; and outdoor
lighting for residential parking lots and residential carports with less than eight vehicles per site shall comply with one of the
§I50.0(k)9B:
following requirements:
i. Shall comply with §I50.0(k)9A; or
ii. Shall comply with the applicable requirements in § 1 10.9, § 130.0, § 130.2, § 130.4, § 140.7 and § 141.0.
§150.0(k)9C:
For low-rise residential buildings with four or more dwelling units, outdoor lighting not regulated by §I50.0(k)9B or 150.0(k)9D
shall comply with the applicable requirements in $110.9, $130.0, $130.2, §130.4, $140.7 and $141.0.
§I50.0(k)9D:
Outdoor lighting for residential parking lots and residential carports with a total of eight or more vehicles per site shall comply
'
with the applicable requirements in 110.9, § 130.0, § 130.2, § 130.4, § 140.7 and § 141.0.
§ 150.0(k)l0:
Internally illuminated address signs shall comply with § 140.8; or shall consume no more than 5 watts of power as determined
according to §130.0(c).
§ I50.0(k)11:
Lighting for residential parking garages for eight or more vehicles shall comply with the applicable requirements for
nonresidential garages in $110.9, $130.0, § 130. 1, § 130.4, § 140.6, and $141.0.
In a low-rise multifamily residential building where the total interior common area in a single building equals 20 percent or less of
§ I 50.0(k) I 2A:
the floor area, permanently installed lighting for the interior common areas in that building shall be high efficacy luminaires or
controlled by an occupant sensor.
In a low-rise multifamily residential building where the total interior common area in a single building equals more than 20
percent of the floor area, permanently installed lighting in that building shall:
§ I50.0(k)1213:
i. Comply with the applicable requirements in § 110.9, § 130.0, §130. 1, § 140.6 and § 141.0; and
ii. Lighting installed in corridors and stairwells shall be controlled by occupant sensors that reduce the lighting power in each
space by at least 50 percent. The occupant sensors shall be capable of turning the light fully On and Off from all designed paths of
ingress and egress.
Solar Ready Buildings:
Single family residences located in subdivisions with ten or more single family residences and where the application for a
§ 110.10(a)1:
tentative subdivision map for the residences has been deemed complete, by the enforcement agency, on or after January 1, 2014,
shall comply with the requirements of {+110.10 b through §110.10 e .
§ 110.10(a)2:
Low-rise mu Iti-fami ly buildings shall comply with the requirements of § 110.10(b) through § 110.10(d).
The solar zone shall have a minimum total area as described below. The solar zone shall comply with access, pathway, smoke
ventilation, and spacing requirements as specified in Title 24, Part 9 or other Parts of Title 24 or in any requirements adopted by a
local jurisdiction. The solar zone total area shall be comprised of areas that have no dimension less than 5 feet and are no less than
80 square feet each for buildings with roof areas less than or equal to 10,000 square feet or no less than 160 square feet each for
§110.10(b)l:
buildings with roof areas greater than 10,000 square feet.
For single family residences the solar zone shall be located on the roof or overhang of the building and have a total area no less
than 250 square feet. For low-rise multi -family buildings the solar zone shall be located on the roof or overhang of the building or
on the roof or overhang of another structure located within 250 feet of the building or on covered parking installed with the
building project and have a total area no less than 15 percent of the total roof area of the building excluding any skylight area.
§ 110.10(b)2:
All sections of the solar zone located on steep -sloped roofs shall be oriented between 110 degrees and 270 degrees of true north.
§ 110.10(b)3A:
No obstructions, including but not limited to, vents, chimneys, architectural features, and roof mounted equipment, shall be
located in the solar zone.
Any obstruction, located on the roof or any other part of the building that projects above a solar zone shall be located at least twice
§I 10.10(b)3B:
the distance, measured in the horizontal plane, of the height difference between the highest point of the obstruction and the
horizontal projection of the nearest point of the solar zone, measured in the vertical plane.
§ 110.10(b)4:
For areas of the roof designated as solar zone, the structural design loads for roof dead load and roof live load shall be clearly
indicated on the construction documents.
The construction documents shall indicate: a location for inverters and metering equipment and a pathway for routing of conduit
§110.10(c):
from the solar zone to the point of interconnection with the electrical service (for single family residences the point of
interconnection will be the main service panel); a pathway for routing of plumbing from the solar zone to the water -heating
system.
§ 110. 10(d):
A copy of the construction documents or a comparable document indicating the information from § 110.10(b) through §110. 10(c)
shall be provided to the occupant.
§ 110.10(e)1:
The main electrical service panel shall have a minimum busbar rating of 200 amps.
The main electrical service panel shall have a reserved space to allow for the installation of a double pole circuit breaker for a
§1 10.10(e)2:
future solar electric installation. The reserved space shall be: positioned at the opposite (load) end from the input feeder location or
main circuit location, and permanently marked as "For Future Solar Electric".
is
4
4
HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY
Project Name
New Residence
Date
12/17/2015
System Name
HVAC 1
Floor Area
1,586
ENGINEERING CHECKS
SYSTEM LOAD
Number of Systems
1
COIL
CFM
Total Room Loads 1,129
Return Vented Lighting
Return Air Ducts
Return Fan
Ventilation 0
Supply Fan
Supply Air Ducts
TOTAL SYSTEM LOAD
COOLING
PEAK COIL HTG.
PEAK
Heating System
Sensible
Latent CFM
Sensible
Output perSystem 89,000
24,450
1,685 569
25,324
Total Output Btuh 89,000
0
Output Btuh/s ft 56.1
0
0
Cooling System
01
0
Output perSystem 58,000
0
0 0
0
Total Output Btuh 58,000
0
1,685
0
Total Output Tons 4.8
0
0
Total Output Stuh/s ft 36.6
Total Output s ft/Ton 328.1
24,450
25,324
Air System
CFM perSystem
2,000
HVAC EQUIPMENT SELECTION
Airflow cfm
2,000
Carrier 24ANB760/58CVX110
43,299 6,102
89,000
Airflow cfm/s ft
1.26
Airflow cfm/Ton
413.8
Outside Air %
0.0%
Total Adjusted System Output
(Adjusted for Peak Design conditions)
TIME OF SYSTEM PEAK
43,299 6,102
Aug 3 PM
89,000
Outside Air cfm/s ft 0.00
Jan 1 AM
Note: values above given at ARI conditions
HEATING SYSTEM PSYCHROMETRICS
Airstream Temperatures at Time of Heating Peak
26 OF 72 OF
Outside Air
0 cfm Supply Fan
2,000 cfm
72 OF
14
72 OF 114 OF
Heating Coil
_
114 OF
ROOM
72 OF
COOLING SYSTEM PSYCHROMETRICS (Airstream Temperatures at Time of Cooling Peak)
112/78°F 76/62°F 76/62°F 56/55°F
Outside Air
0 cfm Supply Fan Cooling Coil
2,000 cfm
76/62°F _
56 / 55 OF
46.6% ROOM
t�
76/62°F
EnergyPro 6.7 by EnergySoft User Number: 6712 Run Code: 2015-12-17708:11:52 /D: Page 22 of 40
r
L_
4
HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY
Project Name
New Residence
Date
12/17/2015
System Name
HVAC 2,3
Floor Area
3,134
ENGINEERING CHECKS
SYSTEM LOAD
Number of Systems
2
COIL
CFM
Total Room Loads 2,473
Return Vented Lighting
Return Air Ducts
Return Fan
Ventilation 0
Supply Fan
Supply Air Ducts
TOTAL SYSTEM LOAD
COOLING PEAK COIL HTG.
PEAK
Heating System
Sensible
Latent CFM
Sensible
Output per System 51,000
55,066
3,331 1,234
52,455
Total Output Btuh 102,000
0
Output Btuhls ft 32.5
0
0
Cooling System
0
0
Output per System 35,500
0
0 0
0
Total Output Btuh 71,000
0
0
1 55,066 3,331
0
Total Output Tons 5.9
0
Total Output Btuh/s ft 22.7
Total Output s ft/Ton 529.7
52,455
Air System
CFM per System
1,200
HVAC EQUIPMENT SELECTION
Airflow cfm
2,400
Carrier 24ANB736/58CVX070
53,432 6,923
102,000
Airflow cfm/s ft
0.77
Airflow cfm/Ton 405.6
Outside Air %
0.0%
Total Adjusted System Output
(Adjusted for Peak Design conditions)
TIME OF SYSTEM PEAK
53,432 6,923
Aug 3 PM
102,000
Jan 1 AM
Outside Air cfm/s ft 0.00
Note: values above given at ARI conditions
HEATING SYSTEM PSYCHROMETRICS
Airstream Temperatures at Time of Heating Peak
26 OF 72 OF
Outside Air
0 cfm Supply Fan
2,400 cfm
72 OF
72 OF 112 OF
Heating Coil
II
112 OF
( ROOM
72 OF
COOLING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Cooling Peak
112/78°F 76/62°F 76/62°F 55/54°F
0'
Outside Air AP -
0 cfm Supply Fan Cooling Coil
2,400 cfm
76 / 62 OF
LLE U
55 / 54 OF
46.2% ROOM
76 / 62 OF
EnergyPro 6.7 by EnergySoft User Number: 6712 RunCode: 2015-12-17708:11:52 /D: Page 23 of 40
HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY
Project Name
A New Residence
Date
12/17/2015
System Name
HVAC 4
Floor Area
722
ENGINEERING CHECKS
SYSTEM LOAD
Number of Systems
1
COIL
CFM
Total Room Loads 737
Return Vented Lighting
Return Air Ducts
Return Fan
Ventilation 0
Supply Fan
Supply Air Ducts
TOTAL SYSTEM LOAD
COOLING
PEAK COIL HTG.
PEAK
Heating System
Sensible
Latent CFM
Sensible
Output per System 89,000
16,216
767 457
20,326
Total Output Btuh 89,000
0
Output Btuhls ft 123.3
0
0
Cooling System
0
0
Output per System 58,000
0
0 0
0
Total Output Btuh 58,000
0
767
0
Total Output Tons 4.8
0
0
Total Output Btuh/s ft 80.3
Total Output s ft/Ton 149.4
16,216
20,326
Air System
CFM per System
2,000
HVAC EQUIPMENT SELECTION
Airflow cfm
2,000
Carrier 24ANB760/58CVX110 43,986 5,146
89,000
Airflow cfm/s ft
2.77
Airflow cfm/Ton
413.8
Outside Air %
0.0%
Total Adjusted System Output 43,986 5,146
(Adjusted for Peak Design conditions)
TIME OF SYSTEM PEAK Aug 3 PM
89,000
Outside Air cfmis ft 0.00
Note: values above given at ARI conditions
Jan 1 AM
HEATING SYSTEM PSYCHROMETRICS
Airstream Temperatures at Time of Heating Peak
26 OF 72 OF
�O 0
Outside Air
0 cfm Supply Fan
2,000 cfm
72 OF
72 OF 114 OF
Heating Coil 114 OF
ROOM
(( 72 OF
COOLING SYSTEM PSYCHROMETRICS (Airstream Temperatures at Time of Cooling Peak)
112/78°F 76162°F 76/62°F 55/54°F
Outside Air
0 cfm Supply Fan Cooling Coil 55 / 54 OF
2,000 cfm
45.5% I ROOM
76/62°F ll 76/62°F
EnergyPro 6.7 by EnergySoff User Number: 6712 Run Code: 2015-12-17708:11:52 /D: Page 24 of 40
SYSTEM HEATING AND COOLING LOADS SUMMARY
e
Fesidence
Date
1211712015
System Name
HVAC 5
Floor Area
1,163
ENGINEERING CHECKS
SYSTEM LOAD
Number of Systems
1
COIL
CFM
Total Room Loads 1,032
Return Vented Lighting
Return Air Ducts
Return Fan
Ventilation 0
Supply Fan
Supply Air Ducts
TOTAL SYSTEM LOAD
COOLING
PEAK COIL HTG.
PEAK
Heating System
Sensible
Latent CFM
Sensible
Output perSystem 71,000
19,276
1,661 434
19,249
Total Output Btuh 71,000
0
Output Btuh/s ft 61.0
0
0
Cooling System
0
0
Output perSystem 46,000
0
0 0
0
Total Output Btuh 46,000
0
1,661
0
Total Output Tons 3.8
0
0
Total Output Btuhls ft 39.6
Total Output s ft/Ton 303.4
1 19,276
19,249
Air System
CFM perSystem
1,600
HVAC EQUIPMENT SELECTION
Airflow cfm
1,600
Carrier 24ANB748/58CVX090
29,887 7,250
71,000
Airflow cfm/s ft
1.38
Airflow cfm/Ton
417.4
Outside Air%
0.0%
Total Adjusted System Output
(Adjusted for Peak Design conditions)
TIME OF SYSTEM PEAK
29,887 7,250
Aug 3 PM
71,000
Jan 1 AM
tside Air cfm/s ft 0.00
ENote:alues above given at ARI conditions
HEATING SYSTEM PSYCHROMETRICS
Airstream Temperatures at Time of Heating Peak
26 OF 72 OF
Outside Air
0 cfm Supply Fan
1,600 cfm
72 OF
72 OF 114 OF
Heating Coil
II
114 OF
ROOM
72 OF
COOLING SYSTEM PSYCHROMETRICS (Airstream Temperatures at Time of Cooling Peak
112/78°F 70/59°F 70/59°F 52/52°F
Outside Air
0 cfm Supply Fan Cooling Coil
1,600 cfm
70 / 59 OF
52 / 52 OF
51.8% ROOM �.
70 / 59 OF
EnergyPro 6.7 by EnergySoft User Number: 6712 Run Code: 2015-12-17708:11:52 /D: Page 25 of 40
r�
•
4)
ROOM LOAD SUMMARY
Project Name I Date
A New Residence 12/17/2015
System Name Floor Area
HVAC 1 . 1,586
ROOM LOAD SUMMARY
ROOM COOLING PEAK COIL COOLING PEAK I COIL HTG. PEAK
Zone Name Room Name Mult. CFM Sensible Latent CFM SensibleII— Latent CFM Sensible
master Zone Master Suite 1 1 1,1291 24,4501 1,685 1,129 24,4501 1,6851 5691 25,324
PAGE TOTAL
TOTAL*
*T
1,129
24,4501
1,6851
569
25_324
1,129
24,450
1,685
569
25,324
I EnergyPro 6.7 by EnergySoft User Number: 6712 RunCode: 2015-12-17708:11:52 /D: Page 26 of 40 1
•
•
C�
J
ROOM HEATING PEAK LOADS
Project Name
A New Residence
Date
12/17/2015
ROOM INFORMATION
DESIGN CONDITIONS
Room Name Master Suite
Floor Area 1,586.0 ft2
Indoor Dry Bulb Temperature 72 T
Time of Peak Jan 1 AM
Outdoor Dry Bulb Temperature 26 OF
Conduction
Area
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
to
Ceiling
U -Value
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
AT 'F
=
=
_
=
_
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
46
Btu/hr
R-38 Roof(R.38.2x14.16)
1,586.0
0.0260
46
1,897
R-21 Wall (W 19.2x6.16)
2,841.0
0.0690
46
9,017
dual non metal tinted. 32.29
449.0
0.3200
46
6,609
Slab -On -Grade
perim = 140.0
0.7300
46
4,701
'R-0 Interior Wall
584.0
0.3560
0
0
Items shown with an asterisk (') denote conduction
Infiltration:[ 1.00 X 1.064
Schedule Air Sensible
Fraction
through an interior surface
X 1,586 X
Area
another room
9.00 X 0.266
Height ACH
Page Total
/60] X
AT
22,225
= 3,100
TOTAL HOURLY HEAT LOSS FOR ROOM 25,324
EnergyPro 6.7 by EnergySoft User Number: 6712 RunCode: 2015-12-17T08:11:52 /D: Page 30 of 40
n
174
ROOM HEATING PEAK LOADS
Project Name
A New Residence
Date
12/17/2015
ROOM INFORMATION
DESIGN CONDITIONS
Room Name GreabDining/KWEntq
Floor Area 3,134.0 ft'
Indoor Dry Bulb Temperature 72 OF
Time of Peak Jan 1 AM
Outdoor Dry Bulb Temperature 26 OF
Conduction
Area
U -Value
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
AT 'F
c
=
_
=
=
_
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
46
Btu/hr
R-38 Roof(R.38.2x14.16)
3,134.0
X
0.0260
46
3,748
R-21 Wall (W.19.2x6.16)
4,997.7
X
X
0.0690
46
15,863
Wood Door
24.0
0.5000
46
552
dual non metal tinted. 32.29
1,353.3
X
X
X
0.3200
46
19,921
Slab -On -Grade
perim = 186.0
0.7300
46
6,246
'R-0 Interior Wall
788.0
0.3560
0
0
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
Items shown with an asterisk (') denote conduction
Infiltration:[ 1.00 X 1.064
Schedule Air Sensible
Fraction
through an interior surface
X 3,134 X
Area
to another room
9.00 X 0.266
Ceiling Height ACH
Page Total
/60] X
AT
46,329
_ 6,125
TOTAL HOURLY HEAT LOSS FOR ROOM 52,455
EnergyPro 6.7 by EnergySoft User Number: 6712 Run Code: 2015-12-17T08:11:52 ID: Page 31 of 40
•
C7
•
ROOM HEATING PEAK LOADS
Project Name
A New Residence
Date
12/17/2015
ROOM INFORMATION
DESIGN CONDITIONS
Room Name Bedroom Office
Floor Area 722.0 ftZ
Indoor Dry Bulb Temperature 72 °F
Time of Peak Jan 1 AM
Outdoor Dry Bulb Temperature 26 OF
Conduction
Area
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
to
Ceiling
U -Value
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
AT *F
=
=
_
_
_
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
46
Btu/hr
R-38 Roof(R.38.2x14.16)
722.0
0.0260
46
864
R-21 Wall (W.19.2x6.16)
3,071.0
0.0690
46
9,747
dual non metal tinted. 32.29
279.0
0.3200
46
4,107
Slab -On -Grade
perm = 125.0
0.7300
46
4,198
'R-0 Interior Wall
584.0
0.3560
0
0
Items shown with an asterisk (') denote conduction
Infiltration:[ 1.00 X 1.064
Schedule Air Sensible
Fraction
through an interior surface
X 722 X
Area
another room
9.00 X 0.266
Height ACH
Page Total
/60] X
AT
18,915
c 1,411
TOTAL HOURLY HEAT LOSS FOR ROOM 20,326
EnergyPro 6.7 by EnergySoft User Number: 6712 Run Code: 2015-12-17T08:11:52 ID: Page 32 of 40
r
ROOM HEATING PEAK LOADS
Project Name Date
A New Residence 12/17/2015
ROOM INFORMATION
DESIGN CONDITIONS
Room Name Casita
Floor Area 1,163.0 ft2
Indoor Dry Bulb Temperature 72 OF
Time of Peak Jan 1 AM
Outdoor Dry Bulb Temperature 26 OF
Conduction
Area
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
to
Ceiling
U -Value
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
AT *F
=
=
_
c
=
=
=
=
=
-
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
46
Btu/hr
R-38 Roof(R.38.2x14.16)
1,163.0
0.0260
46
1,391
R-21 Wall (W.19.2x6.16)
1,893.0
0.0690
46
6,008
dual non metal tinted. 32.29
297.0
0.3200
46
4,372
Slab -On -Grade
pen .m = 155.0
0.7300
46
5,205
'R-0 Interior Wall
511.0
0.3560
0
0
Items shown with an asterisk (') denote conduction
Infiltration:[ 1.00 X 1.064
Schedule Air Sensible
Fraction
through an interior surface
X 1,163 X
Area
another room
9.00 X 0.266
Height ACH
Page Total
/60] X
AT
16,976
_ 2,273
TOTAL HOURLY HEAT LOSS FOR ROOM 19,249
EnergyPro 6.7 by EnergySoft User Number: 6712 Run Code: 2015-12-17708:11:52 ID: Page 33 of 40
•
RESIDENTIAL ROOM COOLING LOAD SUMMARY
Project Name Date
A New Residence 12/17/2015
ROOM INFORMATION DESIGN CONDITIONS
Room Name
Master Suite
Outdoor Dry Bulb Temperature
112 OF
Floor Area
1,586.0 ft2
Outdoor Wet Bulb Temperature
78 OF
Indoor Dry Bulb Temperature
76 OF
Outdoor Daily Range:
34 OF
Ooaaue Surfaces
R-38 Roof(R.38.2x14.16)
R-21 Wall (W.19.2x6.16)
R-21 Wall (W.19.2x6.16)
R-21 Wall (W.19.2x6.16)
R-21 Wall (W.19.2x6.16)
`R-0 Interior Wall
Orientation
(KO
(NE)
(SE)
(St/10
(NW)
Area
X
X
X
X
X
X
X
X
X
U -Factor
X
X
X
X
X
X
X
X
X
CLTD'
=
=
=
=
=
=
=
=
=
1,586.0
0.0260
56.0
918.0
0.0690
29.0
513.0
0.0690
31.0
550.0
0.0690
31.0
860.0
0.0690
30.2
584.0
0.3560
0.0
0.0
17.2
120.0
26.5
0.0
17.2
6.0
26.5
0.0
17.2
10.0
Page Total
Items shown with an asterisk (') denote conduction through an interior surface to another room.
1. Cooling Load Temperature Difference (CLTD)
Fenestration
K
8
9
11
10
Q
P
N
M
Orientation
(NE)
(NE)
(SE)
(SW
(NW)
(NW)
(NW)
(NW)
(NIM,
Shaded Unshaded
Btu/hr
2,309
1,837
1,097
1,176
1,7941
1 8,2141
Area
X
X
X
X
X
X
X
X
X
GLF
+
+
+
+
+
+
+
+
+
Area
X
X
X
X
X
X
X
X
X1
GLF
=
=
=
=
=
=
=
=
-
0.0
17.2
6.0
26.5
0.0
17.2
96.0
26.5
112.0
17.2
0.0
23.8
75.0
17.2
0.0
23.8
0.0
17.2
120.0
26.5
0.0
17.2
6.0
26.5
0.0
17.2
10.0
26.5
0.0
17.2
8.0
26.5
0.0
17.2
10.0
26.5
Page Total
159
2,543
1,922
1,287
3,178
159
265
212
265
Internal Gain Btu/hr
Occupants 4.8 Occupants X 245 Btuh/occ. = 1,1
Equipment 1,586 Floor Area X 0.50 ver/sgft =2.7
Infiltration: 1.064 X 0.88 X 65.42 X 36 = 2,215
Air Sensible CFM ELA AT
TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 24.450
Latent Gain Btu/hr
( Occupants 4 8 Occupants X 155 Btuh/occ. = 737
Infiltration: 4,771 X 0.88 X 65.42 X 0.00344 = 948
Air Sensible CFM ELA AW
I TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 7371
I EnergyPro 6.7 by EnergySoft User Number., 6712 Run Code: 2015-12-17708:11:52 ID: Page 34 of 40 1
i
•
n
RESIDENTIAL ROOM COOLING LOAD SUMMARY
Project Name
Date
A New Residence
12/17/2015
ROOM INFORMATION
DESIGN CONDITIONS
Room Name Master Suite
Outdoor Dry Bulb Temperature
112 OF
Floor Area 1,586.0 ft2
Outdoor Wet Bulb Temperature
78 OF
Indoor Dry Bulb Temperature 76 OF
Outdoor Daily Range:
34 OF
Opaque Surfaces Orientation Area U -Factor
CLTD'
Btu/hr
X
X
=
X
X
=
X
X
=
X
X
=
X
X
=
X
X
=
X
X
=
X
X
=
X
X
=
Page Total
0
Items shown with an asterisk (') denote conduction through an interior surface to another room.
1. Cooling Load Temperature Difference (CLTD)
Shaded
Unshaded
Fenestration Orientation Area GLF Area
GLF
Btu/hr
L (NtL,9 0.0 X 17.2 +
6.0
X 26.5 =
159
X +
X -
X +
X =
X +
X =
X +
X =
X +
X =
X +
X =
X +
X =
X + I
X =
Page Total
159
Internal Gain
Btu/hr
Occupants 48 Occupants X 245
Btuh/occ.
=
Equipment 1,586 Floor Area X 0.50
w/sgft
L1,166
=
2,707
Infiltration: 1.064 X 0.88 X 65.42 X 36 =
2,215
Air Sensible CFM ELA AT
TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM
24,450
Latent Gain
Btu/hr
Occupants 4 8 Occupants X 155
Btuh/occ.
=
737
Infiltration: 4,771 X 0.88 X 65.42 X 0.00344 —
948
Air Sensible CFM ELA AW
TOTAL HOURLY LATENT HEAT GAIN FOR ROOM
737
Ene Pro 6.7 by EnerqySoft User Number 6712 Run Code: 201 5-1 2-1 7 70 8:11:52 /D:
Page 35 of 40
•
•
0
I RESIDENTIAL ROOM COOLING LOAD SUMMARY
12/17/2015
DESIGN CONDITIONS
Room Name
Great/Dining/Kit/Entry IOutdoor
Dry Bulb Temperature
112 OF
Floor Area
3,134.0 ft2
I
Outdoor Wet Bulb Temperature
78 OF
Indoor Dry Bulb Temperature
76 OF
Outdoor Dailv Ranae:
34 OF
Opaque Surfaces
R-38 Roof(R.38.2x14.16)
R-21 Wall (W. 19.2x6.16)
Wood Door
R-21 Wall (W. 19.2x6.16)
R-21 Wall (W.19.2x6.16)
R-21 Wall (W. 19.2x6.16)
"R-0 Interior Wall
Orientation
(M
(NE)
(NE)
(SE)
(SW)
(NVI0
Area
X
X
X
X
X
X
X
X
X
U -Factor
X
X
X
X
X
X
X
X
X
CLTD'
=
=
=
=
=
=
=
=
=
3,134.0
0.0260
56.0
976.0
0.0690
29.0
24.0
0.5000
29.0
1,850.7
0.0690
31.0
814.0
0.0690
31.0
1,357.0
0.0690
30.2
788.0
0.3560
0.0
23.8
108.2
17.2
0.0
23.8
40.0
17.2
0.0
Page Total
Items shown with an asterisk (') denote conduction through an interior surface to another room.
1. Cooling Load Temperature Difference (CLTD)
Fenestration
F
2
E
C
B
A
1
16
13
Orientation
(SE)
(SE)
(SE)
(SE)
(SE)
(SE)
(SE)
(SW)
(S W)
Shaded Unshaded
Btu/hr
4,563
1,953
348
3,959
1,741
Z831
0
1 15,3941
Area
X
X
X
X
X
X
X
X
X
GLF
+
+
+
+
+
+
+
+
+
Area
X
X
X
X
X
X
X
X
X
GLF
=
=
=
=
=
=
=
=
-
0.0
17.2
7.1
23.8
96.0
17.2
0.0
23.8
209.0
17.2
0.0
23.8
32.0
17.2
0.0
23.8
32.0
17.2
0.0
23.8
108.2
17.2
0.0
23.8
40.0
17.2
0.0
23.8
275.0
17.2
0.0
23.8
75.0
17.2
0.0
1 23.8
Page Total
Btu/hr
169
1,647
3,587
549
549
1,857
686
4,7191
1,287
15,0511
Internal Gain Btu/hr
Occupants 9.4 Occupants X 245 Btuh/occ. = 2,3
Equipment 3.134 Floor Area X 0.50 w/sgft =
Infiltration: 1.064 X 0.88 X 129.26 X 36 =4.3
Air Sensible CFM ELA AT
TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 55,066
Latent Gain Btu/hr
Occupants 9 4 Occupants X 155 Btuh/occ. = 1,457
Infiltration: 4,771 X 0.88 X 129.26 X 0.00344 - 1,873
Air Sensible CFM ELA AW
1,45
I EnergyPro 6.7 by EnergySoft User Number: 6712 RunCode: 2015-12-17708:11:52 /D: Page 36 of 40 1
•
•
0
RESIDENTIAL ROOM COOLING LOAD SUMMARY
Project Name
Date
A New Residence
12/17/2015
ROOM INFORMATION
DESIGN CONDITIONS
Room Name
Great/Dining/Kit/Entry
Outdoor Dry Bulb Temperature
112 OF
Floor Area
3,134.0 ftz
Outdoor Wet Bulb Temperature
78 OF
Indoor Dry Bulb Temperature 76 OF
Outdoor Daily Range:
34 OF
Opaque Surfaces
Orientation Area U -Factor
CLTD'
Btulhr
X
X
=
X
X
=
X
X
=
X
X
=
X
X
=
X
X
=
X
X
=
X
X
=
X
X
=
Page Total
0
Items shown with an asterisk (')
denote conduction through an interior surface to another room.
1. Cooling Load Temperature
Difference (CLTD)
Shaded
Unshaded
Fenestration
Orientation Area GLF Area GLF
Btu/hr
D
(SIM 0.0 X 17.2 +
36.0 X
23.8 =
858
T
(NIA9 0.0 X 17.2 +
144.0 X
26.5 =
3,814
S
(NKK 0.0 X 17.2 +
32.0 X
26.5 =
848
R
(NVI9 0.0 X 17.2 +
32.0 X
26.5 =
848
15
(NM 0.0 X 17.2 +
86.0 X
26.5 =
2,278
14
(NV) 0.0 X 17.2 +
24.0 X
26.5 =
636
12
(NM 0.0 X 17.2 +
125.0 X
26.5 =
3,311
X +
X
=
X I +
X
=
Page Total
12.592
Internal Gain
Btu/hr
Occupants
9.4 Occupants X 245
Btuh/occ.
=
2,303
Equipment
3,134 Floor Area X 0.50
w/sgft
Infiltration: 1.064
X 0.88 X 129.26 X 36 =
4,377
Air Sensible
CFM ELA AT
TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM
55,066
Latent Gain
Btu/hr
Occupants
9.4 Occupants X 155
Btuh/occ.
=
1,457
Infiltration: 4,771
X 0.88 X 129.26 X 0.00344 =
1,873
Air Sensible
CFM ELA AW
TOTAL HOURLY LATENT HEAT GAIN FOR ROOM
1,457
EnerqvPro 6.7 by Ener Soft
User Number: 6712 RunCode: 2015-12-17708:11:52 ID:
Page 37 of 40
RESIDENTIAL ROOM COOLING LOAD SUMMARY
Project Name
A New Residence
ROOM INFORMATION DESIGN CONDITIONS
Room Name Bedroom Office Outdoor Dry Bulb Temperature
Floor Area 722.0 ft2 Outdoor Wet Bulb Temperature
Indoor Dry Bulb Temperature 76 OF Outdoor Dailv Rancie:
Onaaue Surfaces
R-38 Roof(R.38.2x14.16)
R-21 Wall (W.19.2x6.16)
R-21 Wall (W. 19.2x6.16)
R-21 Wall (W. 19.2x6.16)
R-21 Wall (W 19.2x6.16)
'R-0 Interior Wall
Orientation
Date
12/17/2015
Area
X
X
X
X
X
X
X
X
X
U -Factor
X
X
X
X
X
X
X
X
X
CLTD'
=
=
=
=
=
=
=
=
=
722.0
0.0260
56.0
653.0
0.0690
29.0
833.0
0.0690
31.0
846.0
0.0690
31.0
739.0
0.0690
30.2
584.0
0.3560
-6.0
0.0
17.2
4.0
23.8
0.0
17.2
12.5
23.8
0.0
17.2
12.5
Page Total
Items shown with an asterisk (') denote conduction through an interior surface to another room.
1. Cooling Load Temperature Difference (CLTD)
Fenestration
Orientntinn
(NE)
(SE)
(SE)
(SE)
(SW)
(SIA9
(Sth9
(NKK
(Nw)
Shaded Unshaded
Area
X
X
X
X
X
X
X
X
X
GLF
+
+
+
+
+
+
+
+
+
Area
X
X
X
X
X
X
X
X
X
GLF
=
=
=
=
=
=
=
=
=
0.0
17.2
72.0
26.5
0.0
17.2
30.0
23.8
0.0
17.2
6.0
23.8
0.0
17.2
6.0
23.8
0.0
17.2
4.0
23.8
0.0
17.2
12.5
23.8
0.0
17.2
12.5
23.8
0.0
17.2
88.0
26.5
0.0
17.2
48.0
26.5
Page Total
112 OF
78 OF
34 OF
Btu/hr
1,051
1,307
1,782
1,810
1,541
-1.247
6,
Btu/hr
1,907
715
143
143
95
298
298
2,331
1,271
7.202
Internal Gain Btu/hr
Occupants 2 2 Occupants X 245 Btuh/occ. 531
Equipment 722 Floor Area X 0.50 w/sgft 1,232
Infiltration: 1.064 X 0.88 X 29.78 X 36 = C
Air Sensible CFM ELA AT
TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 16,216
Latent Gain ' Btu/hr
Occupants 2 2 Occupants X 155 Btuh/occ. = 336
Infiltration: 4.771 X 0.88 X 29.78 X 0.00344 - 432
Air Sensible CFM ELA AW
TOTAL HOURLY LATENT HEAT GAIN FOR ROOM
I EnergyPro 6.7 by EnergySoft User Number.' 6712 RunCode: 20 1 5-1 2-1 7 708:11:52 /D: Paae 38 of 40 1
•
•
s
RESIDENTIAL ROOM COOLING LOAD SUMMARY
Project Name Date
A New Residence 12/17/2015
ROOM INFORMATION DESIGN CONDITIONS
Room Name Casita Outdoor Dry Bulb Temperature 112 OF
Floor Area 1,163.0 ft2 Outdoor Wet Bulb Temperature 78 °F
Indoor Dry Bulb Temperature 70 OF Outdoor Daily Range: 34 °F
ODaaue Surfaces
R-38 Roof(R.38.2x14.16)
R-21 Wall (W 19.2x6.16)
R-21 Wall (W.19.2x6.16)
R-21 Wall (W 19.2x6.16)
R-21 Wall (W 19.2x6.16)
`R-0 Interior Wall
Orientation
(W)
(NE)
(SE)
(SW)
(NIM
Area
X
X
X
X
X
X
X
X
X
U -Factor
X
X
X
X
X
X
X
X
X
CLTD'
=
=
=
=
=
=
=
=
=
1,163.01
0.0260
56.0
289.0
0.0690
29.0
693.0
0.0690
31.0
327.0
0.0690
31.0
584.0
0.0690
30.2
511.0
0.3560
6.0
23.8
0.0
6.0
23.8
0.0
15.0
23.8
0.0
1 15.0
23.8
Page Total
Items shown with an asterisk (') denote conduction through an interior surface to another room.
1. Cooling Load Temperature Difference (CLTD)
I Fpnpstratinn
EE
DD
CC
42
BB
AA
HH
KK
JJ
OriPntatinn
(NE)
(NE)
(NE)
(NE)
(SE)
(SE)
(SE)
(Sim
(SIM
Btu/hr
1,693
578
1,482
699
1,218
1,091
1 6,7631
Shaded
Area
X
X
X
X
X
X
X
X
X
GLF
17.2 +
17.2 +
17.2 +
17.2 +
17.2 +
17.2 +
17.2 +
17.2 +
17.2 +
Unshaded
Area
X
X
X
X
X
X
X
X
XI
GLF
=
=
=
=
=
=
=
=
=
0.0
6.0
26.5
0.0
6.0
26.5
0.0
6.0
26.5
0.0
68.0
26.5
0.0
6.0
23.8
0.0
15.0
23.8
0.0
6.0
23.8
0.0
15.0
23.8
0.0
1 15.0
23.8
Page Total
Btu/hr
159
159
159
1,801
143
358
143
358
3,
rnal Gain Btu/hr
ants 3 5 Occupants X 245 Btuh/occ.
ment 1,163 Floor Area X 0.50 w/sgft
I Infiltration: 1.064 X 0.94 X 47.97 X 42 = 2,005
Air Sensible CFM ELA AT
I TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 19,2761
Latent Gain Btu/hr
Occupants 3 5 Occupants X 155 Btuh/occ. = 541
Infiltration: 4.771 X 0.94 X 47.97 X 0.00523 = 1,120
Air Sensible CFM ELA AW
5411
I EnergyPro 6.7 by EnergySoft User Number: 6712 RunCode: 2015-12-17T08:11:52 /D: Page 39 of 40 1
r
•
•
RESIDENTIAL ROOM COOLING LOAD SUMMARY
Project Name
Date
A New Residence
12/17/2015
ROOM INFORMATION
DESIGN CONDITIONS
Room Name
Casita
Outdoor Dry Bulb Temperature
112 OF
Floor Area
1,163.0 ftz
Outdoor Wet Bulb Temperature
78 OF
Indoor Dry Bulb Temperature 70 OF
Outdoor Daily Range
34 OF
Opaque Surfaces
Orientation Area U -Factor
CLTD'
Btu/hr
X
X
=
X
X
=
X
X
=
X
X
=
X
X
=
X
X
=
X
X
=
X
X
=
X
X
=
Page Total
0
Items shown with an asterisk (')
denote conduction through an interior surface to another room.
1. Cooling Load Temperature
Difference (CLTD)
Shaded
Unshaded
Fenestration
Orientation Area GLF Area
GLF
Btu/hr
LL
(SK) 0.0 X 17.2 +
6.0
X 23.8 =
143
GG
(SlM 0.0 X 17.2 +
6.0
X 23.8 =
143
FF
(SIM 0.0 X 17.2 +
6.0
X 23.8 =
143
44
(NM 0.0 X 17.2 +
68.0
X 26.5 =
1,801
43
(NM 0.0 X 17.2 +
68.0
X 26.5 =
1,801
X +
X =
X +
X =
X +
X =
X +
X =
Page Total
4,031
Internal Gain
Btu/hr
Occupants
3 5 Occupants X 245
Btuh/occ.
=
855
Equipment
1,163 Floor Area X 0.50
w/sgft
=
1,985
Infiltration: 1.064
X 0.94 X 47.97 X 42 =
2,005
Air Sensible
CFM ELA AT
TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM
19,276
Latent Gain
Btu/hr
Occupants
3 5 Occupants X 155
Btuh/occ.
=
541
Infiltration: 4.771
X 0.94 X 47.97 X 0.00523 —
1,120
Air Sensible
CFM ELA OW
TOTAL HOURLY LATENT HEAT GAIN FOR ROOM
541
EnerqyPro 6.7 by Ener Soft
User Number: 6712 Run Code: 2015-12-17T08:11:52 /D:
Page 40 of 40
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: New Residence Calculation Date/Time: 09:12, Fri, Sep 09, 2016
Calculation Description: Title 24 Analysis Input File Name: Hideaway Lot 48-51 -Stracts-1 5.xml
CFI R -PRF -01
Page 1 of 13
GENERAL INFORMATION
05
ENERGY USE SUMMARYr
06
:H T1
07' 1'�
01
02Calculation
T Project Name New Residence
Description Title 24 Analysis
Standard Design
Proposed Design
:Compliance Margin
03
04
Project Location Lots 48-51, The Hideaway
City La Quinta 05
Standards Version Compliance 2015
06
08
Zip Code 92253
Climate Zone CZ15
07
09
Compliance Manager Version
Software Version
BEMCmpMgr 2013-4 (744)
EnergyPro 6.6
10
Building Type Single Family
11
Front Orientation (deg/Cardinal) 135
12
Project Scope Newly Constructedn&S
_
0.00
Number of Dwelling Units
1
14
Total Cond. Floor Area (ft2) 6605
-1.66
Number of Zones
4
16
Slab Area (ft2) 6605
0.00
Number of Stories
1
18
20
Addition Cond. Floor Area N/A
Addition Slab Area'(ft2) N/A
i
y,,,-, _ _. � � %_. ..
BUIL
APPHOVEDF%Glazing
Cnr1 '/i/�� PATI\f •
Natural Gas Available
- Percentage (%)
iii. Y:•^.. .;?f� :i. ..
�-� _ �. _. u•... c.rw - u..- — —.
Yes a
36.0%
._ .. _ -
COMPLIANCE RESULTS •'',,�� -� � ~-°' -"- � �,. ��, ��,, ��
01 Building Complies with'Computer' Performancet + a ✓
.. rDATE% ``�f
02 This building incorporates fea{ure`s`that require fiel
ter Under the supervision off a CEC approved HERS provider.
• rE �^ ice_ t 4 Y4 a. !S 't ++.. �'r �1 sf , may'. tAiii�
03 This building incorporates one orimore Special Features shown below {'
r `•,1 �-. � ti:. )t � .,� i" r " a -i ,. � 1l...+r K... � `! ice"'"' � '"
04 .
05
ENERGY USE SUMMARYr
06
:H T1
07' 1'�
C)
08
Energy Use (kTDV/ft2-yr)
Standard Design
Proposed Design
:Compliance Margin
Percent Improvement
Space Heating
5.59
9.36
-3.77
-67.4%
Space Cooling
127.80
118.24;=
9.56
7.5%
IAQ Ventilation
0.75
0.75
_
0.00
0.0%
Water Heating
3.89
5.55
-1.66
-42.7%
Photovoltaic Offset
-
0.00
0.00
___
Compliance Energy Total
138.03 _
133.90
4.13
3,0%
Registration Number: 215-N63054000-000000000-0000 Registration Date/Time: 2016-09-09 09:18:49 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF111-04072016-744 Report Generated at: 2016-09-09 09:14:07
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1 R -PRF -01
Project Name: New Residence Calculation Date/Time: 09:12, Fri, Sep 09, 2016 Page 2 of 13
Calculation Description: Title 24 Analysis Input File Name: Hideaway Lot 48-51 -Stracts-1 5.xml
REQUIRED SPECIAL FEATURES
The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis.
• Window overhangs and/or fins
HERS FEATURE SUMMARY
The following is a summary of the features that must be field -verified by a certified HERS Rater as a condition for meeting the modeled energy performance for this computer analysis. Additional detail is
provided in the building components tables below.
Building -level Verifications:
• IAQ mechanical ventilation
Cooling System Verifications:
• Minimum Airflow
• Verified EER
• Verified SEER
• Refrigerant Charge
• Fan Efficacy Watts/CFM
HVAC Distribution System Verifications:
• Duct Sealing
• Low -leakage Air Handling Unit /
Domestic Hot Water System Verifications:x*—
• --None—
ENERGY
-None—
ENERGY DESIGN RATING / '<% ( t � I I I t i { � I � 1 i '� I I } (
This is the sum of the annual TDV energy consumption,focenergy A componenfs'include'd itn-fhe perfor`m'ance complian6 approach foi`the Stariclard Design Building (Energy Budget) and the annual
TDV energy consumption for lighting and components not -regulated by Title 24; Part -6 (such as domestic:appliances`and consumer electronics) and accounting for the annual TDV energy offset by an
on-site renewable energy system. � , 18 .� i' it'i �.../ � 1 i..% � 1-N
Reference Energy Use Energy Design Rating Margin Percent Improvement
Total Energy (kTDV/f2-yr)* 173.15
169.02 4.13 2.4%
• includes calculated Appliances and Miscellaneous Energy Use (AMEU)
BUILDING - FEATURES INFORMATION
01
02
03
04
05
06
07
Project Name
Conditioned Floor Area (ft2)
Number of Dwelling
Units
Number of Bedrooms
Number of Zones
Number of Ventilation
Cooling Systems
Number of Water
Heating Systems
New Residence
6605
1
5
4
2
2
Registration Number: 215-N630540OC-000000000-0000
CA Building Energy Efficiency Standards - 2013 Residential Compliance
Registration Date/Time: 2016-09-09 09:18:49
Report Version - CF1R-04072016-744
HERS Provider: CaICERTS Inc.
Report Generated at: 2016-09-09 09:14:07
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: New Residence Calculation Date/Time: 09:12, Fri, Sep 09, 2016
Calculation Description: Title 24 Analysis Input File Name: Hideaway Lot 48-51-Stracts-15.xml
CFI R -PRF -01
Page 3 of 13
ZONE INFORMATION
01
02
03
04
05
06
07
Zone Name
Zone Type
HVAC System Name
Zone Floor Area
(ft)
Avg, Ceiling
Height
Water Heating System 1
Water Heating System 2
master Zone
Conditioned
HVAC 11
1586
9
DHW Sys 1
Construction
grt din kit zone
Conditioned
HVAC 2,32
3134
9
DHW Sys 1
bed
Conditioned
HVAC 43
722
9
DHW Sys 1
SE Wall
casita zone
Conditioned
HVAC 54
1163
9
DHW Sys 3
112
OPAQUE SURFACES
01
02
03
04
05
06
07
08
Name
Zone
Construction
Azimuth
Orientation Gross Area (ftz)
Window & Door Area (ft2)
Tilt (deg)
NE Wall
'master Zone
R-21 Wall (W.19.2x6.16)
45
Right
1020
102
90
SE Wall
master Zone -
,.
R-21 Wall (W.19.2x6.16)
135
Front
625
112
90
SW Wall
master Zone
R-21 Wall (W.19.2x6.16)
225
Left
625
75
90
NW Wall
- mastei�Zone
�
r R-21�Wall (W.19.2x6.16)�!
�f315
(Back
1020
160
90
R-38 Roof
'master Zone
t,�
( ;F2-38 Roof(R.38_2x1.4".16)k
4 � r.
S J i) 11 k�
1586
NE Wall 2
.' grt d'in kit'zone
A
R=,21 Wall'(WA9;2x6.16)—
-
45 %�
r... .
`Ri ht
...,. 9 .- ,
1000
24
90
SE Wall 2
grt din kit ione
_I
s•- R=21 WaW(W.19.2z6.16)-%
135 11
i.J Front 1 s
2375
524.34
90
SW Wall 2
grt din kit zone
R-21 Wall (W.19.2x6.16)
225
Left
1200
386
90
NW Wall 2
grt din kit zone
R-21 Wall (W.19.2x6.16)
315
Back
1800
443
90
R-38 Roof 2
grt din kit zone
R-38 Roof(R.38.2x14.16)
3134
NE Wall 3
bed
R-21 Wall (W.19.2x6.16)
45
Right
725
72
90
SE Wall 3
bed
R-21 Wall (W.19.2x6.16)
135
Front
875
42
90
SW Wall 3
bed
R-21 Wall (W.19.2x6.16)
225
Left
875
29
90
NW Wall 3
bed
R-21 Wall (W.19.2x6.16)
315
Back
875
136
90
R-38 Roof 3
bed
R-38 Roof(R.38.2x14.16)
722
NE Wall 4
casita zone
R-21 Wall (W.19.2x6.16)
45
Right
375
86
90
SE Wall 4
casita zone
R-21 Wall (W.19.2x6.16)
135
Front
720
27
90
SW Wall 4
casita zone
R-21 Wall (W.19.2x6.16)
225
Left
375
48
90
NW Wall 4
casita zone
R-21 Wall (W.19.2x6.16)
315
Back
720
136
90
R-38 Roof 4
casita zone
R-38 Roof(R.38.2x14.16)
1163
Registration Number: 215-N630540oC-000000000-0000
CA Building Energy Efficiency Standards - 2013 Residential Compliance
Registration Date/Time: 2016-09-09 09:18:49
Report Version - CF111-04072016-744
HERS Provider: CaICERTS Inc.
Report Generated at: 2016-09-09 09:14:07
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: New Residence Calculation Date/Time: 09:12, Fri, Sep 09, 2016
Calculation Description: Title 24 Analysis Input File Name: Hideaway Lot 48-51 -Stracts-1 5.xml
CFIR-PRF-01
Page 4 of 13
ATTIC
01 02
Name Construction
Attic master Zone Attic Roofmaster Zone
03
Type
Ventilated
04 05 06
Roof Rise Roof Reflectance Roof Emittance
3 0.1 0.85
07
Radlant.Barder,Cool
Yes'
08
Roof
No
t
Attic grt din kit zone Attic Roofgrt din kit zone
Ventilated
3 0.1 0.85
Yes
No
Attic bed Attic Roofbed
Ventilated
3 0.1 0.85
Yes
No
Attic casita zone Attic Roofcasita zone
Ventilated
3 0.1 0.85
Yet
No
NEN1
Registration Number: 215-N6305400C-000000000-0000 Registration Date/Time: 2016-09-09 09:18:49 HERS Provider: CaICERTS Inc.
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF111-04072016-744 Report Generated at: 2016-09-09 09:14:07
t
ry
Registration Number: 215-N6305400C-000000000-0000 Registration Date/Time: 2016-09-09 09:18:49 HERS Provider: CaICERTS Inc.
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF111-04072016-744 Report Generated at: 2016-09-09 09:14:07
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: New Residence Calculation Date/Time: 09:12, Fri, Sep 09, 2016
Calculation Description: Title 24 Analysis Input File Name: Hideaway Lot 48-51 -Stracts-1 5.xml
CF1 R -PRF -01
Page 5 of 13
WINDOWS
01
02
03
04
05
06
07
08
09
10
Name
Type
Surface (Orientation -Azimuth)
Width (ft) Height (ft)
Multipll
er
Area
(ft2)
U -factor
SHGC
Exterior Shading
K
Window
NE Wall (Right -45)
--
---
1
6.0
0.33
0.20
Insect Screen (default)
8
Window
NE Wall (Right -45)
--
---
1
96.0
0.34
0.16
Insect Screen (default)
9
Window
SE Wall (Front -135)
14.0
8.0
1
112.0
0.34
0.16
Insect Screen (default)
11
Window
SW Wall (Left -225)
7.5
10.0
1
75.0
0.34
0.16
Insect Screen (default)
10
Window
NW Wall (Back -315)
12.0
10.0
1
120.0
0.33
0.20
Insect Screen (default)
Q
Window
NW Wall (Back -315)
--
--
1
6.0
0.33
0.20
Insect Screen (default)
P
Window
NW Wall (Back -315)
---
--
1
10.0
0.33
0.20
Insect Screen (default)
N
Window
j `; NW Wall (Back -315)
---
----
1
8.0
0.33
0.20
Insect Screen (default)
M
Window
' NW Wall (Back -315)
--
1
10.0
0.33
0.20
Insect Screen (default)
L
Window
NW WallBack-315)
(
---
---
1
6.0
0.33
0.20
Insect Screen (default)
F
Window4
_ _ --SE Wall (Front -135)
---
--
1
7.1
0.33
0.20
Insect Screen (default)
2
Window
-':SE Wall_2,(Front-135) �^� t"=
1:3 8.0 f
1
96.0
0.33
0.20
Insect Screen (default)
E
Window
_-' SE Wall 2 Front=135 t I
- r1 (., )� 19.0
` 11.011
x`209.0
0.33
0.20
Insect Screen (default)
C
Window
I ' t'` SE V1l`a_11�2(Fronf 135j
4'.0
8.0 t
U 1 U320
•�
0.33
0.20
Insect Screen (default)
B
Window
�' t SE Wall 2J Front -135
t �: r( )
4:0
'• �t `SA
LIZ
32.0
0.33
0.20
Insect Screen (default)
A
Window
ySE Wall 2 -(Front -1 35)
8.8
12.3 V
1
108.2
0.33
0.20
Insect Screen (default)
1
Window
SE Wall 2 (Front -135)
4.0
10.0
1
40.0
0.95
0.49
Insect Screen (default)
16
Window
SW Wall 2 (Left -225)
27.5
10.0
1
275.0
0.34
0.16
Insect Screen (default)
13
Window
SW Wall 2 (Left -225)
7.5
10.0
1
75.0
0.34
0.16
Insect Screen (default)
D
Window
SW Wall 2 (Left -225)
--
--
1
36.0
0.33
0.20
Insect Screen (default)
T
Window
NW Wall 2 (Back -315)
12.0
12.0
1
144.0
0.33
0.20
Insect Screen (default)
S
Window
NW Wall 2 (Back -315)
4.0
8.0
1
32.0
0.33
0.20
Insect Screen (default)
R
Window
NW Wall 2 (Back -315)
4.0
8.0
1
32.0
0.33
0.20
Insect Screen (default)
15
Window
NW Wall 2 (Back -315)
8.6
10.0
1
86.0
0.34
0.16
Insect Screen (default)
14
Window
NW Wall 2 (Back -315)
3.0
8.0
1
24.0
0.34
0.16
Insect Screen (default)
12
Window
NW Wall 2 (Back -315)
12.5
10.0
1
125.0
0.34
0.16
Insect Screen (default)
19
Window
NE Wall 3 (Right -45)
--
---
1
72.0
0.34
0.16
Insect Screen (default)
Z
Window
SE Wall 3 (Front -135)
--
---
1
30.0
0.33
0.20
Insect Screen (default)
Y
Window
SE Wall 3 (Front -135)
---
---
1
6.0
0.33
0.20
Insect Screen (default)
Registration Number: 215-N6305400C-000000000-0000 Registration Date/Time: 2016-09-09 09:18:49 HERS Provider: CaICERTS Inc.
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF111-04072016-744 Report Generated at: 2016-09-09 09:14:07
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: New Residence Calculation Date/Time: 09:12, Fri, Sep 09, 2016
Calculation Description: Title 24 Analysis Input File Name: Hideaway Lot 48-51 -Stracts-1 5.xml
CF1 R -PRF -01
Page 6 of 13
X
Window
SE Wall 3 (Front -135)
---- --
1
6.0
0.33
0.20
1 Insect Screen (default)
W
Window
SW Wall 3 (Left -225)
--- ---
1
4.0
0.33
0.20
Insect Screen (default)
V
Window
SW Wall 3 (Left -225)
---- --
1
12.5
0.33
0.20
Insect Screen (default)
U
Window
SW Wal -13 (Left -225)
---- ---
1
12.5
0.33
0.20
Insect Screen (default)
18
Window
NW Wall 3 (Back -315)
11.0 8.0
1
88.0
0.34
0.16
Insect Screen (default)
17
Window
NW Wall 3 (Back -315)
6.0 8.0
1
48.0
0.34
0.16
Insect Screen (default)
EE
Window
NE Wall 4 (Right -45)
--- ---
1
6.0
0.33
0.20
Insect Screen (default)
DD
Window
NE Wall 4 (Right -45)
--- --
1
6.0
0.33
0.20
Insect Screen (default)
CC
Window
NE Wall 4 (Right -45)
--- --
1
6.0
0.33
0.20
Insect Screen (default)
42
Window
NE Wall 4 (Right -45)
--- ---
1
68.0
0.34
0.16
Insect Screen (default)
BB
Window
SE Wall 4 (Front -135)
---- --
1
6.0
0.33
0.20
Insect Screen (default)
AA
Window
SE Wall 4 (Front -135)
---- ---
1
15.0
0.33
0.20
Insect Screen (default)
HH
Window
SE Wall 4 (Front -135)
--- ---
1
6.0
0.33
0.20
Insect Screen (default)
KK
Window
�' SW Wall 4 (Left -225)
--- ---
1
15.0
0.33
0.20
Insect Screen (default)
JJ
Windows
' 'SW Wall 4 (Left -225)
--- ---
1
15.0
0.33
0.20
Insect Screen (default)
LL
Window
SW Wall`47(Left-225) (- ZI ___
1
6.0
0.33
0.20
Insect Screen (default)
GG
Window
' SW Wall 4 (Celt -225) #
' -
1 /-6.0
0.33
0.20
Insect Screen default
FF
Window
r,' SWWall4 Left -225
( ) ` 1i
'-'_
- t` �i -
L,
6;0:
0.33
0.20
Insect Screen (default)
44
Window
f NW Wall 41Bach-315 4
J( )� P
s
-? -T
1.
68.0
0.34
0.16
Insect Screen (default)
43
Window
NW Wall 4 (Back -315)
--- ---
1
68.0
0.34
0.16
Insect Screen (default)
DOORS
01 02 03 04
Name Side of Building Area (ft2) U -factor
23 NE Wall 2 24.0 0.50
Registration Number: 215-N6305400C-000000000-0000
CA Building Energy Efficiency Standards - 2013 Residential Compliance
Registration Date/Time: 2016-09-09 09:18:49
Report Version - CF111-04072016-744
HERS Provider: CaICERTS Inc.
Report Generated at: 2016-09-09 09:14:07
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: New Residence Calculation Date/Time: 09:12, Fri, Sep 09, 2016
Calculation Description: Title 24 Analysis Input File Name: Hideaway Lot 48-51-Stracts-15.xml
CF1 R -PRF -01
Page 7 of 13
OVERHANGS AND FINS
01
02
03
04
Overhang
05 06
07
08 09
Left Fin
10
11
12 13
Right Fin
14
Window
9
Depth
10
Dlst Up
0.1
Left
Extent
10
Right
Extent Flap Ht.
10 0
Depth
0
Top Up DIstL
0 0
Bot Up
0
Depth
0
Top Up
0
Dist R
0
Bot Up
0
11
14
0.1
14
14 0
0
0 0
0
0
0
0
0
10
10
0.1
10
10 0
0
0 0
0
0
0
0
0
2
14
0.1
14
14 0
0
0 0
0
0
0
0
0
E
14
0.1
14
14 0
0
0 0
0
0
0
0
0
C
14
0.1
14
14 0
0
0 0
0
0
0
0
0
B
14
0.1
14
14 0
0
0 0
0
0
0
0
0
A
141
0.1
14
14 0
0
0 0
0
0
0
0
0
1
14,
0.1
14
14 0
0
0 0
0
0
0
0
0
16
20
0.1
20
_ 20 0
0
0 0
0
0
0
0
0
13
20
0.1 ;^.r 20
20, 0� .
—0"'—
0 rl 0
0
0
0
0
0
T
S
14 X0.1
�#14
yFL�O���
�� 0
Ii 0t'j,
oil r
f7 oil I [Ik�" ry
0
0
0
0
0
0
0
0
0
0
R
! r` 140:1
jJ14
x140;.0
`f on
0
0
0
0
0
15
14
0:1
) 4 `
` '14— ' 0
i- b
0'- "` 0- .
0
0
0
0
0
14
14
0.1
14
14 0
0
0 0
0
0
0
0
0
12
14
0.1
14
14 0
0
0 0
0
0
0
0
0
18
10
0.1
10
10 0
0
0 0
0
0
0
0
0
17
10
0.1
10
10 0
0
0 0
0
0
0
0
10
Registration Number: 215-N6305400C-000000000-0000 Registration Date/Time: 2016-09-09 09:18:49 HERS Provider: CaICERTS Inc.
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CFIR-04072016-744 Report Generated at: 2016-09-09 09:14:07
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: New Residence Calculation Date/Time: 09:12, Fri, Sep 09, 2016
Calculation Description: Title 24 Analysis Input File Name: Hideaway Lot 48-51 -Stracts-1 5.xml
nPen119 CI IDCAPC rnuerM1Inr --
CF1 R -PRF -01
Page 8 of 13
----��� ��... r-vr vv.•v1\VV IIVI\J ---
01 02 03 04 05 06 07
Construction Name
Surface Type
Construction Type
Framing
Total Cavity
R-value
Winter Design
U -value
Assembly Layers
03
04
05
06
07
Name
Zone
Attic Roofmaster Zone
Attic Roofs
Wood Framed Ceiling
2x4 Top Chord of Roof Truss @ 24
in. O.C.
none
0.644
• Cavity / Frame: no insul. / 2x4 Top Chid
Roof Deck: Wood Siding/sheathing/decking
Roofing: Light Roof (Asphalt Shingle)
R-38 Roof(R.38.2xl4.16)
Ceilings (below
attic)
Wood Framed Ceiling
2x4 @ 16 in. O.C.
R38
0.025
• Inside Finish: Gypsum Board
Cavity/Frame: R-9.1 /2x4
Over Floor Joists: R-28.9 insul.
3134
186
None
0.8
No
Slab 3
• Inside Finish: Gypsum Board
722
125
None
0.8
No
Slab 4
• Cavity / Frame: R-21 / 2x6
R-21 Wall (W.19.2x6.16)
Exterior Walls ,
Wood Framed Wall
2x6 @ 16 in. O.C.
R 21
0.066
• Exterior Finish: Wood
Siding/sheathing/decking
Attic Roofgrt din kit zone
Attic Roofs' i ti
Wood Framed Ceiling
2x4 Top Chord of Roof Truss @ 24
in. O.C.none
0.644
• Cavity/ Frame: no insul. / 2x4 Top Chid
Roof Deck: Wood Siding/sheathing/decking
Roofing: Light Roof (Asphalt Shingle)
Attic Roofbed
Attic Roofs
Wood Framed:Ceiling
2x4 Top Chord of Roof Truss @ 24
/i ^' 1n: O.C.
.. \ `r=te i
none' l
0.644
Cavity/ Frame: no insul. /2x4 Top Chid
Roof Deck., Wood Siding/sheathing/decking
Roofing: Light Roof (Asphalt Shingle)
9 9 ( A 9)
Attic Roofcasita zone
Attic Roofs
r
e
�Wodd Framed Ceiling's
{ rr
! i i E"'e ) i `
r
2x4=Top Chord of Roof Truss @ 24
�` - �in:-O.C.' ' "�
.�
none
0:644
Cavity/ Frame: no insul. / 2x4 Top Chrd
Y
Roof Deck: Wood Siding/sheathing/decking
Roofing: Light Roof (Asphalt Shingle)
SLAB FLOORS
R -J W f A..-.#
v— M
01
02
03
04
05
06
07
Name
Zone
Area (ft2)
Perimeter (ft)
Edge Insul. R -value & Depth
Carpeted Fraction
Heated
Slab
master Zone
1586
140
None
0.8
No
Slab 2
grt din kit zone
3134
186
None
0.8
No
Slab 3
bed
722
125
None
0.8
No
Slab 4
casita zone
1163
155
None
0.8
No
BUILDING ENVELOPE - HERS VERIFICATION
01 02 03 04
Quality Insulation Installation (QII) Quality Installation of Spray Foam Insulation Building Envelope Air Leakage CFM50
Not Required Not Required Not Required
Registration Number: 215-N6305400C-000000000-0000
CA Building Energy Efficiency Standards - 2013 Residential Compliance
Registration Date/Time: 2016-09-09 09:18:49
Report Version - CF111-04072016-744
HERS Provider: CaICERTS Inc.
Report Generated at: 2016-09-09 09:14:07
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: New Residence Calculation Date/Time: 09:12, Fri, Sep 09, 2016
Calculation Description: Title 24 Analysis Input File Name: Hideaway Lot 48-51-Stracts-15.xml
CFI R -PRF -01
Page 9 of 13
WATER HEATING SYSTEMS
01
02
03
04
01
02
03
04
05 06
Name
DHW Sys 1 - 1/2
System Type
DHW
Distribution Type
Pipe Insulation, All Lines
Water Heater
DHW Heater 1
Number of Heaters Solar Fraction (%)
2 .0%
DHW Sys 3 - 1/1
DHW
Pipe Insulation, All Lines
DHW Heater 3
1 .0%
WATER HEATERS
01
02
03
04
05
06
07
Name
08
Name
DHW Heater 1
Heater Element Type
Natural Gas
Tank Type
Small Storage
Tank Volume
(gal)
75
Energy Factor or
Efficiency
0.65
Input Rating
65000-Btu/hr0
Tank Exterior
Insulation
R -value
Standby Loss
(Fraction)
0
DHW Heater 3
Natural Gas
Small Storage
50
0.62
40000-Btu/hr
0
yr
0
Cooling Component 3
WATER HEATING - HERS VERIFICATION
01
t� . 02 I
—03, r----..� .
%04 Pft
05
06
07
Name
J
r' • Pipe Insulation
! l• `�-- j ! } r
r' i Paullel Piping ]
}
Compact Distribution
'..
r
Poinf Use
Recirculation
Control
Central DHW
DHW Sys 1 - 1/2
' ter' �! \7
was 1 + L t ci
j--
r
Other Heating and Cooling
System
Distribution
Cooling Component 2
DHW Sys 3 - 1/1
✓ --`"
�ri �'—`"`
yr
Heating Component 3
Cooling Component 3
HVAC Fan 3
Air Distribution System 3
SPACE CONDITIONING SYSTEMS
01
02
03
04
05
06
SC Sys Name
System Type
Heating Unit Name
Cooling Unit Name
Fan Name
Distribution Name
Cooling Component 1:1-leating Component 1:Air
Distribution System 1:HVAC Fan 1:1
Other Heating and Cooling
System
Heating Component 1
Cooling Component 1
HVAC Fan 1
Air Distribution System 1
Cooling Component 2:Heating Component 2:Air
Distribution System 2:HVAC Fan 2:1
Other Heating and Cooling
System
Heating Component 2
Cooling Component 2
HVAC Fan 2
Air Distribution System 2
Cooling Component 3:Heating Component 3:Air
Distribution System 3:HVAC Fan 3:1
Other Heating and Cooling
System
Heating Component 3
Cooling Component 3
HVAC Fan 3
Air Distribution System 3
Cooling Component 4:Heating Component 4:Air
Distribution System 4:HVAC Fan 4:1
Other Heating and Cooling
System
Heating Component 4
Cooling Component 4
HVAC Fan 4
Air Distribution System 4
Registration Number: 215-N630540oC-000000000-0000 Registration Date/Time: 2016-09-0909:18:49 HERS Provider: CaiCERTS Inc.
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CFSR-04072016-744 Report Generated at: 2016-09-09 09:14:07
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: New Residence Calculation Date/Time: 09:12, Fri, Sep 09, 2016
Calculation Description: Title 24 Analysis Input File Name: Hideaway Lot 48-51-Stracts-15.xm1
CFI R -PRF -01
Page 10 of 13
HVAC - HEATING UNIT TYPES
01
02
01
02
03
Name
Type
Efficiency
Heating Component 1
CntrlFurnace - Fuel -fired central furnace
80 AFUE
Heating Component 2
CntrlFurnace - Fuel -fired central furnace
80 AFUE
Heating Component 3
CntrlFurnace - Fuel -fired central furnace
80 AFUE
Heating Component 4
CntrlFurnace - Fuel -fired central furnace
80 AFUE
HVAC - COOLING UNIT TYPES
01
02
03 04
05
06
07
Name
System Type
Efficiency
EER SEER
Zonally Controlled
Multi -speed
Compressor
HERS Verification
Cooling Component 1
SplitAirCond
13
16
Not Zonal
Single Speed
Cooling Component
Required
350
Required
Required
Required
1 -hers -cool
Cooling Component 2
r;
_ SplitAirCond - `
13
16
Not Zonal
Single Speed
Cooling Component
Required
350
Required
Required
Required
2 -hers -cool
Cooling Component 3
\ _
` SplitAirCond
n rr
11 133
� i
y6
Zonally, Controlled
11 1 r ?t orf--
Single Speed
CoolingComponent
P
3 -hers -cool
Cooling Component 4
S IitAirC d `.�
P r
,I it �3 �
1
J U16 {f
U tNot Zonal
Single Speed
Cooling Component
4 -hers -cool
HVAC COOLING - HERS VERIFICATION
f %-IF i,-,. 9 j
01
02
03
04
05
06
Name
Verified Airflow
Airflow Target
Verified EER
Verified SEER
Verified Refrigerant
Charge
Cooling Component 1 -hers -cool
Required
350
Required
Required
Required
Cooling Component 2 -hers -cool
Required
350
Required
Required
Required
Cooling Component 3 -hers -cool
Required
350
Required
Required
Required
Cooling Component 4 -hers -cool
Required
350
Required
Required
Required
Registration Number: 215-N6305400C-000000000-0000 Registration Date/Time: 2016-09-09 09:18:49 HERS Provider: CaiCERTS Inc.
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-04072016-744 Report Generated at: 2016-09-09 09:14:07
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: New Residence Calculation Date/Time: 09:12, Fri, Sep 09, 2016
Calculation Description: Title 24 Analysis Input File Name: Hideaway Lot 48-51 -Stracts-1 5.xml
CF1 R -PRF -01
Page 11 of 13
HVAC - DISTRIBUTION SYSTEMS
01
02
03
04
05
06
07
Name
Type
Duct Leakage
Insulation R -value
Duct Location
Bypass Duct
HERS Verification
Air Distribution System 1
DuctsAttic
Specified Lower Leakage
8
Attic
None
Air Distribution System
Ducts
Ducts
Target
Air Distribution System 1 -hers -dist
;�,� Required:
_ 6.0
1 -hers -dist
Air Distribution System 2
DuctsAttic
Specified Lower Leakage
8
Attic
Air Distribution System 2 -hers -dist
Air Distribution System
X6.0`
Not Requited
Target
NotRequiredNot
Required
None
2 -hers -dist
Air Distribution System 3
DuctsAttic
Specified Lower Leakage
8
Attic
None
Air Distribution System
Required
q
Air Distribution System 4 -hers -dist
Target
`6.0—
"Not#Req_uured
Not Required
3 -hers -dist
Air Distribution System 4
DuctsAttic
Specified Lower Leakage
8
Attic
Air Distribution System
,Required
Target
None
4 -hers -dist
HVAC DISTRIBUTION - HERS VERIFICATION
01
!� 02
03
04
05
06
07
08
Type
Duct Leakage
Duct Leakage
Verified Duct
Verified Duct
Buried
Deeply Buried
Low -leakage
Name �-
Verification
Target (%)
Location
Design
Ducts
Ducts
Air Handler
Air Distribution System 1 -hers -dist
;�,� Required:
_ 6.0
Not Required
z Not Required
Not Required
Not Required
Required
Air Distribution System 2 -hers -dist
Requiredf
X6.0`
Not Requited
Not Required r,
NotRequiredNot
Required
Required
Air Distribution System 3 -hers -dist
I� Required ��
6.0
'Not Required
Not;Required �i�,.q,
Not Re uired
Not Required
q
Required
q
Air Distribution System 4 -hers -dist
Req'u`i
`6.0—
"Not#Req_uured
Not Required
Not
Not Required
Required
,Required
HVAC -FAN SYSTEMS
01
01
02
03
04
Name
Type
Fan Power (Watts/CFM)
HERS Verification
HVAC Fan 1
Single Speed PSC Furnace Fan
0.58
HVAC Fan 1 -hers -fan
HVAC Fan 2
Single Speed PSC Furnace Fan
0.58
HVAC Fan 2 -hers -fan
HVAC Fan 3
Single Speed PSC Furnace Fan
0.58
HVAC Fan 3 -hers -fan
HVAC Fan 4
Single Speed PSC Furnace Fan
0.58
HVAC Fan 4 -hers -fan
HVAC FAN SYSTEMS - HERS VERIFICATION
01
02
03
Name
Verified Fan Watt Draw
Required Fan Efficiency (Watts/CFM)
HVAC Fan 1 -hers -fan
Required
0.58
HVAC Fan 2 -hers -fan
Required
0.58
HVAC Fan 3 -hers -fan
Required
0.58
Registration Number: 215-N6305400C-000000000-0000
CA Building Energy Efficiency Standards - 2013 Residential Compliance
Registration Date/Time: 2016-09-09 09:18:49
Report Version - CF1R-04072016-744
HERS Provider: CaICERTS Inc.
Report Generated at: 2016-09-09 09:14:07
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: New Residence Calculation Date/Time: 09:12, Fri, Sep 09, 2016
Calculation Description: Title 24 Analysis Input File Name: Hideaway Lot 48-51 -Stracts-1 5.xmi
HVAC Fan 4 -hers -fan Required 0.58
IAQ (Indoor Air Quality) FANS
01 02 03 04 05
IAQ Recovery
Dwelling Unit IAQ CFM IAQ Watts/CFM IAQ Fan Type Effectiveness(%)
SFam IAQVentRpt 111.05 0.25 Default 0
r i
PROJECT NOTES
Mountlan West Investments �.
Joint Venture with Sedona Homes/Sunrose corp. J
The Hideaway County Club jPr
j.)
/ H E R S
F:2 T (7-, P rn) I'f
L�--= u u u t=�/P u b U \'\=:�a
PROVIDER
CF1 R -PRF -01
Page 12 of 13
06
HERS Verification
Required
05
Number of Fans
1
1
Registration Number: 215-N63054000-000000000-0000 Registration Date/Time: 2016-09-09 09:18:49 HERS Provider: CaICERTS Inc.
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-04072016-744 Report Generated at: 2016-09-09 09:14:07
COOLING VENTILATION
01
02
03
04
Name
Cooling Vent CFM
Cooling Vent Watts/CFM
Total Watts
WH Fan 1
85
0.0470588
4
WH Fan 2
27
0.925926
25
r i
PROJECT NOTES
Mountlan West Investments �.
Joint Venture with Sedona Homes/Sunrose corp. J
The Hideaway County Club jPr
j.)
/ H E R S
F:2 T (7-, P rn) I'f
L�--= u u u t=�/P u b U \'\=:�a
PROVIDER
CF1 R -PRF -01
Page 12 of 13
06
HERS Verification
Required
05
Number of Fans
1
1
Registration Number: 215-N63054000-000000000-0000 Registration Date/Time: 2016-09-09 09:18:49 HERS Provider: CaICERTS Inc.
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-04072016-744 Report Generated at: 2016-09-09 09:14:07
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: New Residence Calculation Date/Time: 09:12, Fri, Sep 09, 2016
Calculation Description: Title 24 Analysis Input File Name: Hideaway Lot 48-51 -Stracts-1 5.xml!
CF1 R -PRF -01
Page 13 of 13
DOCUMENTATION AUTHOR'S DECLARATION STATEMENT
1. t certify that this Certificate of Compliance documentation is accurate and complete.
Documentation Author Name:
Documentation Author Signature:
Tim Scott
Company:
Signature Date:
Scott Design and Title 24, Inc.
2016-09-09 09:18:49
Address:
CEA/HERS Certification Identification (If applicable):
77085 Michigan Drive
City/State/Zip:
Phone:
Palm Desert, CA 92211
760-200-4780
RESPONSIBLE PERSON'S DECLARATION STATEMENT
I certify the following under penalty of perjury, under the laws of the State of California:
1. 1 am eligible under Division 3 of the Business'and Professions Code to accept responsibility for the building design identified on this Certificate of Compliance.
2. 1 certify that the energy features and performance specifications identified this Certificate
on of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of
Regulations. . _J /r '1 '�
`
3. The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents,
worksheets, calculations, plans and_ specifications sub_niitted to
-the enforcement,agency,for approval,with this -building permit application.
Responsible Designer Name: -
Tim Scott
Responsible Designer Signature:
1� C %c xris'CdZ�'-
Company: } H E
Scott
Scott Design
Title 24, Inc.
t--^' t7
i ned: f;
Date Signed-
a. �1 '4:
and
20"�
16-09-09 09:18:49'
Address:
License:
77085 Michigan Drive
na
City/State/Zip:
Phone:
Palm Desert, CA 92211
760-200-4780
Digitally signed by Ca/CERTS. This digital signature is provided in order to secure the content of this registered document, and in noway implies Registration
Provider responsibility for the accuracy of the information.
Registration Number: 215-N6305400C-000000000-0000 Registration Date/Time: 2016-09-09 09:18:49 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version - CF1R-04072016-744 Report Generated at: 2016-09-09 09:14:07