BSOL2016-0025arw0
VO
78-495 CALLE TAMPICO 4
ICE (760) 777-7125
LA QUINTA, CALIFORNIA 92253 FAX (760) 777-7011
COMMUNITY DEVELOPMENT DEPARTMENT INSPECTIONS (760) 777-7153
BUILDING PERMIT
Date: 3/16/2016
Application Number:
BSOL2016-0025
Owner:
Property Address:
54575 AVENIDA VALLEJO
PATRICK RYAN
AM:
774281027
54575 AVENIDA VALLEJO
Application Description:
RYAN / 5.8kW PV SYSTEM - (30) 285W PANEL/(1) INVERTER
LA QUINTA, CA 92253
Property Zoning:
a
M
Application Valuation:
$25,650.00
I
Applicant:
Contractor:
SOLAR CREWMICHAEL
SARRAZIN!'�'
.-.t
840 S ROCHESTER STE D
840 S ROCHESTER STE D
a of
ONTARIO, CA 91761
ONTARIO, C'A.91761
(909)376-6751.
Llc. No.: 931995
LICENSED CONTRACTOR'S DECLARATION
I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter
9 (commencing with Section 7000) of Division 3 of the Business and Professions Code,
and my License is in full force and effect.
License Class: C10, D03 License No.: 931995
Date: 6 contractor
OWNER -BUILDER DECLARATION
I hereby affirm under penalty of perjury that I am exempt from the Contractor's State
License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any
city or county that requires a permit to construct, alter, improve, demolish, or repair
any structure, prior to its issuance, also requires the applicant for the permit to file a
signed statement that he or she is licensed pursuant to the provisions of the
Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division
3 of the Business and Professions Code) or that he or she is exempt therefrom and the
basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a
permit subjects the applicant to a civil penalty of not more than five hundred dollars
($500).:
(1 I, as owner of the property, or my employees with wages as their sole
compensation, will do the work, and the structure is not intended or offered for sale.
(Sec. 7044, Business and Professions Code: The Contractors' State License Law does not
apply to an owner of property who builds or improves thereon, and who does the work
himself or herself through his or her own employees, provided that the improvements
are not intended or offered for sale. -If, however, the building or improvement is sold
within one year of completion, the owner -builder will have the burden of proving that
he or she did not build or improve for the purpose of sale.).
(1 I, as owner of the property, am exclusively contracting with licensed contractors
to construct the project..(Sec. 7044, Business and Professions Code: The Contractors'
State License Law does not apply to an owner of property who builds or improves
thereon, and who contracts for the projects with a contractor(s) licensed pursuant to
the Contractors' State License Law.).
(_ _) I am exempt under Sec. . B.&P.C. for this reason
Date:
Owner:
CONSTRUCTION LENDING AGENCY
I hereby affirm under penalty of perjury that there is a construction lending agency for
the performance of the work for which this permit is issued (Sec. 3097, Civ. C.).
Lender's Name:
Lender's
WORKER'S COMPENSATION DECLARATION
I hereby affirm under penalty of perjury one of the following declarations:
I have and will maintain a certificate of consent to self -insure for workers'
compensation, as provided for by Section 3700 of the Labor Code, for the performance
of the work for which this permit is issued.
I have and will maintain workers' compensation insurance, as required by
Section 3700 of the Labor Code, for the performance of the work for which this permit
is issued. My workers' compensation insurance carrier and policy number are:
Carrier: _ Policy Number: _
I certify that in the performance of the work for which this permit is issued, I
shall not employ any person in any manner so as to become subject to the workers'
compensation laws of California, and agree that, if I should become subject to the.
workers' compensation provisions of Section 3700 of the Labor Co , hall forthwith
comply witht ose provisions.
AV 00,
Date: 416 !� Applican
WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL,
AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO
ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF
COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE,
INTEREST, AND ATTORNEY'S FEES.
APPLICANT ACKNOWLEDGEMENT
IMPORTANT: Application is hereby made to the Building Official for a permit subject to
the conditions and restrictions set forth on this application.
1. Each person upon whose behalf this application is made, each person at whose
request and for whose benefit work is performed under or pursuant to any permit
issued as a result of this application , the owner, and the.applicant, each agrees to, and
shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents, and
employees for any act or omission related to the work being performed under or
following issuance of this permit.
2. Any permit issued as a result of this application becomes null and void if work is
not commenced within 180 days from date of issuance of such permit, or cessation of
work for 180 days will subject permit to cancellation.
I certify that I have read this application and state that the above information is correct.
I agree to comply with all city and county ordinances and state laws relating to building
construction, and hereby authorize representatives of this city to enter upon the
above-mentioned property for inspection purposes.
Date: Signature (Applicant or Agent):
FINANCIAL ••
•
DESCRIPTION.
ACCOUNT:-
„CITY AMOUNT
PAID PAID DATE
BSAS SB1473 FEE
101-0000-20306
0 $2.00
$0.00
PAID BY
METHOD
RECEIPT # '
CHECK #- CLTD BY
Total Paid for BUILDING STANDARDS ADMINISTRATION BSA: $2.00 $0.00
DESCRIPTION
ACCOUNT:
CITY.:,AMOUNT
PAID
PAID DATE
PV SYSTEM - ARRAY, FIRST 20
101-0000-42403
0
$24.17
$0.00
PAID BY
METHOD
RECEIPT #
'CHECK #
;CLTD BY
DESCRIPTION
ACCOUNT
CITY
AMOUNT
PAID
PAID DATE
PV SYSTEM - ARRAY, FIRST 20 PC
101-0000-42600
0
$24.17
$0.00
PAID BY
METHOD:
:RECEIPT #
CHECK ##
CLTD BY
Total Paid -for ELECTRICAL: $48.34. $0.00
DESCRIPTION.
' ACCOUNT . _
CITY
AMOUNT
PAID-
PAID DATE
PERMIT ISSUANCE
101-0000-42404
.0
$91.85
$0.00
PAID BY
METHOD "
RECEIPT #
CHECK'#
CLTD BY
Total Paid for PERMIT ISSUANCE: $91.85 $0.00
TOTALS:0•
Description: RYAN / 5.8kW PV SYSTEM - (30) 285W PANEL/(1) INVERTER
Type: SOLAR Subtype: Status: APPROVED Applied: 2/8/2016 MFA
Parcel No: 774281027 Site Address: 54575 AVENIDA VALLEJO LA QUINTA,CA 92253 Approved: 3/14/2016 AOR
Subdivision: SANTA CARMELITA AT VALE LA QUINTA Block: Lot: 5 Issued:
UNIT 28
Lot Sq Ft: 0 Building Sq Ft: 0 Zoning: Finaled:
Valuation: $25,650.00 Occupancy Type: Construction Type: Expired:
No. Buildings: U No. Stories: 0 No. Unites: 0
Details:. 8.5kW SOLAR ARRAY - (30)-285W SOLARWORLD PANELS W/(1) SOLAR EDGE SE7600A-US AFCI INVERTER [540SF] 2013 CALIFORNIA
ELECTRICAL CODE.
Printed: Wednesday, March 16, 2016 2:16:49 PM 1 of 4 EmirCRUff
SYSTEMS
F9
ADDITIONAL
CHRONOLOGY
CHRONOLOGY TYPE
STAFF NAME`
ACTION DATE .
COMPLETION DATE
NOTES
E-MAIL
AJ ORTEGA
3/9/2016
3/9/2016
EMAIL SENT IN RESPONSE TO VOICEMAIL LEFT BY MICHAEL,
HE MAY RESUBMIT VIA EMAIL:
EMAIL SENT TO APPLICANT THAT PLANS ARE APPROVED AND.
E-MAIL,
AJ ORTEGA
3/14/2016
3/14/2016
PERMIT MAY BE ISSUED ONCE A CITY BUSINESS LICENSE HAS
BEEN ISSUED TO THE CONTRACTOR OF RECORD.
PLAN CHECK PICKED UP
RAMSES SEVILLA
2/16/2016
2/16/2016
MICHAEL PICK UP PLANS
PLAN CHECK SUBMITTAL
AJ ORTEGA
3/10/2016
3/10/2016
VIA EMAIL, CREATED REVIEW.
RECEIVED
PLAN CHECK SUBMITTAL
MARY FASANO
2/8/2016
2/8/2016
RECEIVED
PLAN CHECK SUBMITTAL
RAMSES SEVILLA
2/24/2016
2/24/2016
PLANS RECEIVED BY MAIL
RECEIVED
Printed: Wednesday, March 16, 2016 2:16:49 PM 1 of 4 EmirCRUff
SYSTEMS
F9
Printed: Wednesday, March 16, 2016 2:16:49 PM 2 of 4 NANIF
SYSTEMS
FINANCIAL
INFORMATION
DESCRIPTION ACCOUNT QTY
AMOUNT
PAID PAID DATE RECEIPT # CHECK # METHODPAID BY CLTD
• BY
PHONED APPLICATION (MICHAEL 909-376-6751) AND LEFT
TELEPHONE CALL
$0.00
AJ ORTEGA
$2,00
2/12/2016
BSA:
2/12/2016
PV SYSTEM -ARRAY,
101-0000-42403
0
$24.17
$0.00
MESSAGE THAT THE PLANS ARE READY FOR CORRECTIONS.
TELEPHONE CALL
AJ ORTEGA
3/2/2016
3/2/2016
PHONED APPLICANT REGARDING REMAING•COMMENT, SEE
PV SYSTEM - ARRAY,
101-0000-42600
0
$24.17
$0.00
2ND REVIEW NOTES.
FIRST 20 PC
PHONED APPLICANT REGARDING 311D REVIEW COMMENT,
TELEPHONE CALL
AJ ORTEGA
$48.34
3/10/2016
3/10/2016
SEE REVIEW FOR ADDITIONAL INFORMATION.
CONDITIONS
CONDITION
DATE
DATE DATE
CONTACT
STATUS
REMARKS
NOTES
TYPE
-ADDED
REQUIRED SATISFIED
READY TO ISSUE
AJ ORTEGA 3/14/2016
3/16/2016
3/16/2016
COMPLETE
CONTRACTOR REQUIRED TO HAVE CITY
CHECKLIST
BUSINESS LICENSE PRIOR TO ISSUANCE
CONTACTS
NAME TYPE
NAME
ADDRESSI
CITY
STATE
ZIP
PHONE
FAX
EMAIL
APPLICANT
SOLAR CREW
840 S ROCHESTER STE D
ONTARIO
CA
91761
(951)283-0431
CONTRACTOR
MICHAEL SARRAZIN
840 S ROCHESTER STE D
ONTARIO
CA
91761
(951)283-0431
msarrazin@solarcrew.c
om
OWNER
PATRICK RYAN
54575 AVENIDA
LA QUINTA
CA
92253
(951)283-0431
VALLEJO
Printed: Wednesday, March 16, 2016 2:16:49 PM 2 of 4 NANIF
SYSTEMS
FINANCIAL
INFORMATION
DESCRIPTION ACCOUNT QTY
AMOUNT
PAID PAID DATE RECEIPT # CHECK # METHODPAID BY CLTD
• BY
BSAS SB1473 FEE 101-0000-20306 0
$2.00
$0.00
Total Paid for BUILDING STANDARDS ADMINISTRATION
$2,00
$0.00
BSA:
PV SYSTEM -ARRAY,
101-0000-42403
0
$24.17
$0.00
FIRST 20
PV SYSTEM - ARRAY,
101-0000-42600
0
$24.17
$0.00
FIRST 20 PC
Total Paid for ELECTRICAL:
$48.34
$0.00
Printed: Wednesday, March 16, 2016 2:16:49 PM 2 of 4 NANIF
SYSTEMS
DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE RECEIPT # CHECK # METHOD PAID BY CLTD
BY
PERMIT ISSUANCE 101-0000-42404 0 $91.85 $0.00
Total Paid for PERMIT ISSUANCE: $91.85 $0.00
INSPECTIONS
HUNU INFORMATION
Printed: Wednesday, March 16, 2016 2:16:49 PM 3 of 47
SYSTF MS
N
REVIEWS
RETURNED
STATUS
REMARKS
REVIEW TYPE
REVIEWER
SENT DATE
DUE DATE
DATE
NOTES
1ST BLDG NS (1 WK)
AJ ORTEGA
2/8/2016
2/16/2016
2/12/2016
REVISIONS REQUIRED
SEE ATTACHED CORRECTIONS.
3/2/2016 4:51:58 PM (AJ ORTEGA) - ORIGINALLY
POSTED
2ND BLDG NS (1
STRING SIZING AND QUANTITY REVISED,
WK)
AJ ORTEGA
2/24/2016
3/2/2016
3/2/2016
REVISIONS REQUIRED
CURRENT PROPOSED TEN (10) PANELS PER
STRING TIMES THREE (3) EXCEED THE INVERTER
INPUT CONNECTIONS AND EXTERNAL FUSING IS
REQUIRED.
CLARIFICATION OF PROPOSED "LOAD CENTER"
REQUIRED, INCLUDING PROPOSED LOCATION OF
INSTALLATION.
3RD BLDG NS (1
DAY)
AJ ORTEGA
3/10/2016
3/11/2016
3/10/2016
APPROVED
EMAIL CONFIRMATION RECEIVED, WILL BE A
LOAD CENTER AND BE LOCATED IN A READILY
ACCESSIBLE LOCATION, STATUS CHANGED TO
APPROVED.
HUNU INFORMATION
Printed: Wednesday, March 16, 2016 2:16:49 PM 3 of 47
SYSTF MS
N
Printed.: Wednesday, March 16, 2016 2:16:49 PM 4 of 4 .x
SYSTEMS
ATTACHMENTS
Attachment Type
CREATED
OWNER
DESCRIPTION
PATHNAME
SUBDIR
ETRAKIT ENABLED
BSOL2016-0025- 1ST
DOC
2/12/2016
AJ ORTEGA
1ST REVIEW SOLAR
REVIEW SOLAR
0
CORRECTIONS
CORRECTIONS.pdf
BSOL2016-0025 - 1ST
DOC
2/12/2016
AJ ORTEGA
1ST REVIEW SOLAR
REVIEW SOLAR PLAN
0
PLAN (REDLINED)
(REDLINED).pdf
Printed.: Wednesday, March 16, 2016 2:16:49 PM 4 of 4 .x
SYSTEMS
I
. PROJECT ADDRESS:
RYAN
54575 AVENIDA VALLEJO
LA QUINTA CA 92553
AP N : 774281027 LOT 5
BOOK 19 PAGE 59
SCOPE OF WORK:
30 X 285W ROOF MOUNTED PV MODULES
SYSTEM SIZE 8.55 'kW DC STC
CONTRACTOR:
SOLAR CREW
840 S. ROCHESTER AVENUE "D"
ONTARIO CA 91761
C-10 931995
SHEETINDEX
1. SITE PLAN, VICINITY MAP
2. ROOF PLAN
3. SINGLE LINE DIAGRAM
4. ELECTRICAL CALCULATIONS
5. SIGNAGE
6. RACKING ENGINEERING (3 PGS)
7. EQUIPTMENT SPECKS (4 PGS) -
OrDMF LA QUINTA
WILDINGS SAFETY DEPT.
FOR CONsTRUCT10N
T !f
,1.� K.w <'�r - +:✓ i>rt �.r ,3 :%! S> ': i" Yf't 4' .9�> - s' � y +
xtCalir Potrero aIle P o ile F t ele
^�f� to-�� -•},t ' .rr :rr tt...... Rd,�i..: i'' ,:-::.=• L��.,'= _};
P1: VICINITY MAP
1,01 /O/P/t/
3�
PROJECT SHALL COMPLY WITH: r r_
2013 CBC 2013 CRC 2013 CEC 2013 CFC
CGBSC 301 .1.1 AND CIVIL CODE 1101.1
THE REQUIRE OCfCA41jlN MONOXIDE
DETECTORS S A fl AS PE C R314 & R315.
FEB 2 3 2016
CITYOF LA QUINTA
z2
0
-3Z
P1: SITE PLAN & ,
PROJECTADDRESS: SIGNED:
RYAN MICHAEL SARRAZI
54575 AVENIDA VALLEJO SOLAR CREW
LA QUINTA CA 92553 931995C-10
910 9 � 3 7o 6757
LAQUIN A
BUILDING & SAFETY DE T.
APPROVED
FOR CONSTRUCTION
DATE=
NOTES:
Equipment used shall be new, unless otherwise noted.
Working clearance will be maintained around new and existing equipment (CEC 100.26)
All PV equipment, wiring and interconnection shall be installed by qualified persons.
Photovoltaic conductors shall be identified and grouped.
All exposed PV conductors on roof will be USE -2 or Photovoltaic (PV) type wire
All photovoltaic conductors will be 90; C rated.
All conductors exposed to sunlight shall be listed as "sunlight resistant'.
All exterior conduit, fittings and boxes to be rain -tight and approved for wet location.
All metallic raceways and equipment to be bonded and electrically continuous.
Grounding electrode conductor will be continuous.
Grounding bushings required around per -punched concentric knockouts.
Array equipment shall be grounded; conductors smaller than 6AWG shall be protected.
All equipment shall be listed for the application: UL 1703 for modules, UL 1741 for inverters.
P111 4 �, 7"o jLG� Kj
5�G�12 r t u�2Gb 5 W Z S v P/0 S0"/21 K oor_ ml7G
►— t�t�o �SOM Q_ rid 5T S9G1� L f ��t,,
Zx6 � C7
A 130V
lzoob�
DiS-
60- V1 e,, - ?'
.
MA iN jai V/U Z-
PROJECTADDRESS: SIGNED:
RYAN MICHAEL SARRAZIN
54575 AVENIDA VALLEJO SOLAR CREW
P2: ROOF PLAN LA QUINTA CA 92553 931995 C-10
90 7
z
m
m
� (A m -0
P. 55 m
0
C z0
M
05
z > 0
> > 0
WA
:0
m
m
C-
0
0K Ln
to
-,t. m
0 0m
om>
D
N,
tA Nu
1z,
tcu 0
-0 20
0,0
zMao
Oa
ELECTRICAL CALCULATIONS
OPERATING VOLTAGE _ (10)(31.3)=313.OV
OPERATING CURRENT = (3)(9.2)= 27.6A
MAX PV VOLTAGE & CURRENT CALC'S
RECORD LOW TEMP. (*C): -1
TEMP. COEFF (%/`C): -0.30
OPEN CIRCUIT VOLTAGE (Voc): 39.7V
MAX PV SYSTEM VOLTAGE (PER NEC 690.7)
= (10x39.7) x 1.12=444.64
MAX PV CONTINUOUS CURRENT PER NEC 690.8(A)(1):
(1.25)(Isc)(3 STRINGS)
(1.25)(9.84)(3)= 36.9A
DC CONDUCTOR AMPACITY CALC'S ROOF CONDUIT
EXPECTED MAX AMBIENT TEMP. (*C): 54*
TEMP. CORRECTION NEC, TABLE 310.15(B)(2)(a): 0.50 13/90 mm above
CIRCUIT CONDUCTOR SIZE/TYPE: 8AWG, THWN-2, 90*C
# OF CURRENT CARRYING CONDUCTORS:/ (p
CONDUIT FILL CORR., NEC TABLE 310.15(B)(3)(a): 0.8
CIRCUIT CONDUCTOR AMPACITY, TABLE 310.15(B)(16): 55A
REQUIRED CIRCUIT CONDUCTOR AMPACITY, NEC 690.8(B):
(1.25)(1.25)(Isc)
(1.25)(1.25)(9.84) = 15.375A.
ADJUSTED AMPACITIES COR CONDUCTORS, NEC 310.15:
TEMP. CORRECTION, NEC TABLE 310.15(B)(2)(a)x
CONDUIT FILL CORRECTION, NEC 310.15(B)(3)(a)x
CONDUCTOR AMPACITY, NEC TABLE 10.15(B)(16)
(0.50)(0.8)(55)= 22.OA> 15.4A OK
8AWG, THWN-2, 90*C WIRE IS OK
AC CONDUCTOR AMPACITY CALC'S WALL CONDUIT
# OF INVERTER: 1 '
EXPECTED MAX AMBIENT TEMP. (*C) 50*
TEMP. CORRECTION, NEC TABLE 310.15(B)(2)(a):.82
CIRCUIT CONDUCTOR SIZE/TYPE: 8AWG, THWN-2, 90*C
# OF CURRENT,CARRYING CONDUCTORS: 2
CONDUIT FILL CORR., NEC TABLE 310.15(B)(3)(a): 1.0
CIRCUIT CONDUCTOR AMPACITY, TABLE 310.15(B)(16): 55A
REQUIRED CIRCUIT CONDUCTOR AMPACITY, NEC 690.8(B):
(1.25)(# OF INVERTERS)(MAX INVERTER OUTPUT CURRENT)
(1.25)(1)(32)= 40.OA
ADJUSTED AMPACITIES COR CONDUCTORS, NEC 310.15:
TEMP. CORRECTION, NEC TABLE 310.15(B)(2)(a)x
CONDUIT FILL CORRECTION, NEC 310.15(B)(3)(a)x
CONDUCTOR AMPACITY, NEC TABLE 10.15(B)(16)
(0.82)(1.0)(55)= 45.1A> 40.OA OK
8AWG, THWN-2, 90*C WIRE IS OK
40A PV BREAKER WILL BE PROVIDED
POINT OF INTERCONNECTION, NEC 705.12(D)(2):
(1.2)(BUS RATING) > MAIN BREAKER + PV BREAKER
(1.2)(200A)> 200A + PV BREAKER
PV BREAKER SHALL BE < 40A
40A PV BREAKER OK
P4: ELECTRICAL CALCULATIONS
CITY OF LA QUINTA
BUILDING & SAFETY DEPT.
APPROVED
FOR CONSTRUCTION
DATE BY_�_
76 675 /
PROJECTADDRESS: SIGNED:
RYAN MICHAEL SARRAZIN
54575 AVENIDA VALLEJO SOLAR CREW
LA QUINTA CA 92553 931995 0' X�"
9
ROCK -IT SJ- STem
Designed with the installer in mind.
EcoFasten Solar specializes in solar roof attachments that are the easiest to install, most secure and cost-
effective solutions for installers. EcoFasten offers a wide variety of standard products as well as custom
solutions, for a one-stop source for all of your rooftop anchoring needs. Products are rigorously tested and
approved above and beyond industry standards in-house and by third party agencies. EcoFasten's patented
conical sealing system has been in service in the snow guard and solar industry for two decades.
FeaTU res
• Fastest, easiest to level system on the market
• ETL listed to UL SUB 2703
• Class A Fire rating with Type 1 modules
• Integrated electrical bonding
SYSTem comPonenTS
ROCK -IT MounT
Array SKIrT
• SIMPLE- only 3 components
• Fixed wire management tray
• North-South adjustability of up to 4'
• Only one tool required (1/2" deep well socket)
ROCK -IT COUPLInG
V10 A 11
D&oFasten Solar
EcoFasten Solar products are protected by
the following U.S. Patents:
8,151,522 B2 8,153,700 B2 8,181,398 B2
8,166,713 B2 8,146,299 62 8,209,914 B2
8,245,454 B2 8,272,174 B2 8,225,557 B2
www.ecofastensolar.com info@ecofastensolar.com 877-859-3947
ROCK -IT mounT ASSeMBLY
NOTe: IT'ems 1-12 SHIP assemBLeD
1 5/16"-18 x 1.5" Hex Flange Bolt 300 Series SS
2 Rock -It Mid -Clamp 6005A -T5
3 Compression Spring 300 Series SS
4 Tie Plate 6005A -T5 AL
5 Rock -It Shelf 6005A -T5 AL
6 Flange Level Nut 300 Series SS
7 Packaging O -Ring (Remove Prior to Installation)
8 Rock -It Pedestal 6005A -T5 AL
9 3/8" ID Star Lock Washer 300 Series SS
10 3/8"-16 Hex Tap Bolt 300 Series SS
11 5/16"-18 x .375" Hex Flange Bolt 300 Series SS
12 Rock -It -Slide 6005A -T5 AL
13 5/16" ID EPDM Bonded Washer 300 Series SS
14 5/16" x 4!'l lex Lag Screw or 5/16"-18 X 1.50"
Hex Bolt 300 Series SS
ROCK -IT COUPUnG ASSeMBLY
NOTe: ITems 1-4 SHIP asseMBL.eD
1 5/16"-18 x 1.5" Hex Flange Bolt 300 Series SS
2 Rock -It Coupling Mid Clamp 6005A -T5 AL
3 Compression Spring 300 Series SS
4 Rock -It Coupling Shelf 6005A -T5 AL
www.ecofastensolar.com info@ecofastensolar.com 877-859-3947
array LAYOUT
• Find the required structural attachment points.
Mark these using a vertical (N -S) chalk line on the
center of the rafters.
Spacing may vary depending upon project specific
structural requirements; i.e. high snow and wind
load areas may require lesser bracket spacing in
the E -W axis vs. the maximum spacing. Max spacing
is 48" for portrait orientation and 72" for landscape
orientation. Consult project layout diagram for
project specific bracket spacing on the roof.
Install Rock -It Mounts to predetermined mount
spacing.
• The array skirt sections are the width of a typical
60 cell module - use the array skirt as a guide to
lay out module placement.
Note: The distance between the rows of mounts is calculated by the module dimension N -S plus 1 3/8"
(35mm). Lag screw should be Installed as close to center of exposed shingle as possible.
GreenFasTen FLasHinG insTaLL
1 Locate the rafters and snap horizontal and vertical lines to mark the installation
position for each GreenFasten flashing.
2 Drill a pilot hole (1 /4" diameter) for the lag bolt. Backfill with sealant. EcoFasten Solar
recommends an EPDM mastic.
3 Insert the flashing so the top part.is under the next row of shingles and pushed far
enough up slope to prevent water infiltration through vertical joint in shingles. The
leading edge of flashing must butt against upper row of nails to prevent turning
when torqued.
4 Line up pilot hole with GreenFasten flashing hole.
Insert the lag bolt through the EPDM bonded washer, the Rock -It slide, the gasketed
hole in the flashing and into the rafter.
Torque: The range is between 100-140 torque inch -pounds depending on the type
of wood and time of year. The visual indicator for proper torque is when the EPDM
on the underside of the bonded washer begins to push out the sides as the washer
compresses. If using an impact wrench to install the fasteners be careful not to over
torque the fastener. You may need to stop and use a ratchet to finish the install.
www.ecofastensolar.com info@ecofastensolar.com 877-859-3947
ROCK -IT SYSTem insTaLL
ROCK -IT
SYSTEM'
1 Install EcoFasten Solar Flashing with Rock -It Mounts
Follow GreenFasten Install instructions for flashing and bracket install on composition shingle roofs.
Optimum vertical distance between lag bolts is 13/8" plus module dimension.
Set mounts on eave most row so that the Rock -It Pedestal is on the South end of Rock -It Slide. (ex. image 1)
Set mounts on all upper rows so that the Rock -It Pedestal is on the Norti end of Rock -It Slide. (ex. image 6)
2 Install Array Skirt to Eave Mounts
• Install array skirt starting on west side of array and move east.
3-4 Attach Couplings to Array Skirt
Tighten the west most array skirt bolt on coupling first.
When tightening the east bolt the array skirt sections will be drawn together.
5 Align and Straighten First Row of the Rock -It System with Array Skirt
Use North-South adjustment of the Rock -It pedestal to straighten array skirt.
Tighten screw on side of Rock -It Pedestal to secure it to the Rock -It Slide.
Adjust Flange Level Nut to level the system (optional - can be leveled during or after installation)
6_7 Install 1 st Row of PV Modules
Slide Rock -It Mounts that are upslope down to engage top of first module.
Note: Make sure cable tray is facing upslope.
Torque 1 st and 2nd row of mid -clamps on Rock -It Mounts and Rock -It Couplings to 150 in -lbs.
Note: Torque setting may vary according to module manufacturer,
Install Balance of PV Modules
8_9
Secure wire and electrical components in built in wire tray on Rock -It Mounts and Couplings.
Install next row of panels and torque mid -clamps to secure modules.
Repeat install for all remaining rows of modules.
10 Level the Rock -It System
• When assembly is complete, level the entire system by adjusting Flange Level Nuts.
www.ecofastensolar.com info@ecofastensolar.com 877-859-3947
Ic;rounainG LUG insTaLL
Necessary Components:
- Burndy CL50-1 TN Ground Lug (UL Listing #KDER.E9999)
- 14 AWG - 4 AWG Copper Ground Wire
- 8-32 x 0.5" Serrated Flange Head Bolt (300 Series SS)
- 8-32 Serrated Flange Nut (300 Series SS)
- 11 /32" and 1/4" wrenches or ratchets/sockets
1 The Ground Lug is installed into the T slot on the Rock -It Mount.
2 Slide the Flange Head Bolt on the Ground Lug into T slot on Rock -It Mount.
3 Tighten Flange Nut/Bolt.
4 Place wire in Ground Lug channel and tighten set screw to complete assembly.
lBonDinG AssemBLY anD BonDinG PATH
• Bond Path
Grounding Lug
- Equipment.Grounding
conductor (EGci
generaify to earth
ground
Rock -it Coupling
Rock -It Mount
Integrated Bonding .
www.ecofastensolar.com info@ecofastensolar.com 877-859-3947
THermaL ExPansion anD BonDinG
A thermal expansion gap is
required per each continuous
100' length of modules.
Omit a coupling and leave a 2"
gap in the array skirt and also
between the modules at that
point.
BracKeT sPaonG
Portrait Orientation
Maximum bracket spacing in
portrait orientation is 48" OC.
— Bond Path
0 Grounding Lug
EqulpmentGraundIng
Conductor (EGO.
aenera0 F to earth
grauM
Rack -It Coupling
• Rock -It Mount
Landscape Orientation
Maximum bracket spacing in
landscape orientation is 72" OC.
Spacing may vary depending upon project specific structural requirements; i.e. high snow and wind load
areas may require lesser spacing E -W than the maximum.
sTaGGereD LaY OUT
Staggered Mounting Points
Rock -It Mount =Rock -It Coupling
The array layout instructions in this installation manual offer a
general overview of layout. Periodically, due to a variety of
factors (roof obstacles, shading, etc.) other layouts are required
canTlLever am oFFseT
Cantilever: Maximum cantilever is 25% of module width. For portrait
orientation installations, check layout prior to installing.
Offset: Offset from all roof edges depends on wind speed, snow
loads, local fire and building codes per location
www.ecofastensolar.com info@ecofastensolar.com 877-859-3947
`ROCK -IT
SYSTEJ
ROCK -IT SYSTem
• Fastest, easiest to level system on the market
• ETL listed to UL SUB 2703
• Class A Fire rating with Type 1 modules
• Integrated electrical bonding
• SIMPLE- only 3 components
• Fixed wire management tray
• North-South adjustability of up to 4'
• Only one tool required (12" deep well socket)
Max No. of Panels
300 Modules per ground lug
Materials
300 Ser es Stainless,
6000 Series Aluminum
Max System Voltage
1000VDC
Coating
Black Andodization/Mill Finish
Class A Fire Rating
With UL1703 Type 1 Rated
Lug Specifications
Burndy CL50-1 TN Ground Lug
Modules
(UL Listing #KDER E9999)
Leveling Range
3-4"
Ground Wire
14 AWG 4 AWG Copper
Per above Lug spec.
Ground Wire
Rock -It Slide Range
4"
Max Module Size
64.96"(1 650m m) x
39.05"(992mm) x 2"(50mm)
Min/Max Roof Slope
5:12/12:12
Max Downforce/Uplift Rating
45 PSF
Max Anchor Spacing
72"
Rock -It Mount Load Rating
547lbs with Single 5/16" Lag 3.0
Safety Factor
Skirt Box QTY
6 units
Slide Fastening Hole
5/16" diameter
Mount Box QTY
12 units
Module Cantilever
Lesser of 25% Width, or Module
Installat on Manual
Coupling Box QTY
12 units
Warranty
10 Year Material and Workman-
ship
Codes: National Electric Code, ANSI/NFPA 70, NEC 250, NEC 690, IRC, IBC
Standards: UL 2703, UL 1703
`_*'( To
us
www.ecofastensolar.com
A
U,>EcoFasten Solar
info@ecofastensolar.com
877-8S9-3947
solar-••
SolarEdge Single Phas+
For North America
SE3000A-US / SE380OA-US / SE5000A
SE760OA-US / SE10000A-US / SE1140C
The best choice for SolarEdge enabled systems
Integrated arc fault protection (Type 1) for NEC 2011 690.11 compliance
Superior efficiency (98%)
Small, lightweight and easy to install on provided bracket
Built-in module -level monitoring
Internet connection through Ethernet or Wireless
Outdoor and indoor installation
Fixed voltage inverter, DC/AC conversion only
Pre -assembled Safety Switch for faster installation
Optional — revenue grade data, ANSI C12.1
USA -GERMANY-ITALY-FRANCE -JAPAN CH:NA-AUSI'RAIIA I-IENEI HFH IAN 05 ISRAEI www.solaredge.us
SQ r _ • • :. Single Phase Inverters for North America
SE3000A-US / SE380OA-US / SE5000A-US / SE6000A-US I
SE7600A-US/ SE10000A-US / SE1140OA-US
SE3000A-US jSE3800A-US 1 SESOOOA-US iSE6000A-USI SE760OA-US ; SE1000OA-US ; SE1140OA-US
--- - - - - --- - - - ---------
OUTPUT
9980 @ 208V
Nominal AC Power Output
j 3000 3800 5000 6000 I 7600 11400
VA
10000 @240V
Max. AC Power Output
3300 4150 5400 @ 208V 6000 8350 10800 @ 208V 12000
VA
� 5450 @240V 1 ) 10950 @240V
AC Output Voltage Min: Nom: Maxj11
r
183 - 208 - 229 Vac
AC Output Voltage Min: Nam: Max.111
1
211- 240 - 264 Vac
AC Frequency Min: Nom: Max.111
, 59.3 - 60 - 60.5 (with HI country setting 57 - 60 - 60.5)
H:
Continuous Output Current
IIMax.
I 12.5 16 1 21.�.240V...�...... 25....... f 47.5
A
II l......32....... 42 •@ 240V-
III
GFDI Threshold
i I
A
UHlily Monitoring, Islindi_ng Prolechon, Country Configurable Thresholds Yes
r
Yes
INPUT,
-
-
Recommended Max. DC Power"! -
3750 4750 6250 ! 7500 9500 12400 14250
W
Transformer-less, Ungrounded
I Yes
Max. Input Voltage
500
Vdc
Nom. DC Input Voltage
32S @ 208V / 350 @ 240V
Vdc
Max. Input Current("
i l6.5 Cd 208V .33 @ 208V
95 13 ill 23 34.5
Adc
I 15.5 240V 30.5 @ 240V
Max. Input Short Circuit Current
45
Adc
Reverse-Polarity Protection
Yes
Ground-Fault Isolation Detection
600k-r Sensitivity
Mdxinlum Inverter Efficiency
97.7 98.2 98.3 98.3 i 98 98 98
9b
CEC Weighted Efficiency
97.5 98 97.5 @ 208V 97 5 97.5 97 @ Z08V � 97.5 +
Y6
98, @ 240V ( 975.@ 240V
Nighttime Power Consumption _
. _ _- - < 2.5 4 _ _ < 4
W
ADDITIONAL FEATURES
_
Supported Communication Interfaces
RS485, RS232, Ethernet, ZigBee (optional) 1
Revenue Grade Oata, ANSI C12.1
Optional"' I
Rapid Shutdown -NEC 2014 690.12
Functionality enabled when SolarEdge_ rapid shutdown kit is installedell
STANDARD COMPLIANCE
- - - -
r - - _
Safety
( U1.174.1. UL16998, UU998 , CSA 22.2
Grid Connection Standards
IEEE1547
Emissions _
({
FCC partly class 0
INSTALLATION SPECIFICATIONS
- -
AC output conduit size / AWG range
j 3/4" minimum / 16-6 AWG 3/4" minimum / B-3 AWG
DC Input conduit, size / if of strings /f
'
AWG ranRe
} 3/4" minimum / 1-2 strings / 16-6 AWG 3/4" minimum / 1.2 strings / 14-6 AWG
Dimensions with Safety Switch
30.5 x 13.5 x 7 / 30.5-x 125 x 7.5 /
in /
(HxWxD)
30.Sx12.5x10.5J775x315x260
775 Is 315 1%2 775,x 315x191
mm
Weight with Safety Switch
i Si:2.%23.2 54.7/ 24.7 88 A / 40.1
lb/kg
Cooling
Natural Convection Fans (user replaceable)
Noise.
< 25 <50
d BA
Min.-Max. Operating Temperature
-13 to +140 / -25 to +60 (-40 to +60 version available"I)
'F /'C
Range
Protection Rating
NEMA 3R
I'1 For other regional settings please contact SoNFEdge support
"I likW and lower: Limited to 135%of AC power; 7 6kW and higher: Limited to 125%for kscations where the yearly average high temperature is Auva 777/25'C end to 135% for locations where It Is below 77'F/25'C
For detailed Information, refer to Idto //Wwwsulircdde.ud0L"M11hBnyoic,
do rvewnne eu-de.odf
PIA higher current source maybe used; the imrerter win limit its Input current to the values stated
(,I Revenue grade inverter P/N: SExxxxA-LIStI00NNR2
lsl Rapid shutdown kit P/N: SE1000-11S0-S1
1.I -40 version P/N: 5ExxxxA-L1S000NNLI4
solar =@@
SolarEdge Power Optimizer
Module Add -On For North America
P300 / P400 / P405
PV power optimization at the module -level
— Up to 25% more energy
— Superior efficiency (99.5%�)
— Mitigates all types of module mismatch losses, from manufacturing tolerance to partial shading
- Flexible system design for maximum space utilization
— Fast installation with a single bolt
— Next generation maintenance with module -level monitoring
— Module -level voltage shutdown for installer and firefighter safety
USA - GERMANY - iFALY FRANCE - JAPAN - ChINA - ;SRAF! - AUSFRALIA www.solaredge.us
solar
=a"
SolarEdge Power Optimizer
Module Add-On for North America
P300 / P400 / P405
P300 P400
P405
modules — i for 72 & 6-c 11 modulesj- '
- -^ - -
(for thin film modulesl
- - ni
INPUT
Rated Input DC Power"'
I
300 1 400
405
t W
Absolute Maximum Input Voltage
f
48 80
12S
Vdc
(Voc at lowest temperatu_ re)
MPPT Operating Range
8-48 8-80 !
12.5-105
Vdc
Maximum Short Circuit Current (Isc)
10
Adc
1
Maximum DC Input Current
12.5
Adc
Maximum Efficiency
99.5
%
Weighted Efficiency
-18.8
%
Overvoltage CateggrY___ _-_. _._ _ _
�_• 11
OUTPUT DURING OPERATION (POWER OPTIMIZER CONNECTED TO OPERATING SOLAR_ E_DG_E_ INVERTER)
-
Maximum Output Current
i5
i Adc
Maximum Output Voltage_
60 j
Vdc
_ _ _
OUTPUT DURING STANDBY (POWER OPTIMIZER DISCONNECTED FROM SOL_AREDG_ E INVERTER OR S_ OLA_RE_DGE INVERTER OFF)
Safety Output Voltage per Power Optimizer 1 -
1
�� Vdc
STANDARD COMPLIANCE
EMC
_ _ _
FCC Part15 Class B, IEC600
10-6-2, IEC61000-6-3
Safety
IEC62109-1(class 11 safety), UL1741
t
RoHS ]
_
INSTALLATION SPECIFICATIONS
-- - -� ____Yes
Maximum Allowed System Voltage
1000
Vdc
Pxxx-2 series
141 x 212 x 40.5_ / 5.55 x 8.34 x 1.59
mm J in
Dimensions (W x L x H)
128 x 152 x 27.5 J 128 x 152 x 35 /
x 152 x 48 /
Pxxx-5 series
t
i128
5x5.97xmg 5x'S.97,x1.37.
I
5x5.97x1.89
mm/in
Weight (including cables) Pxxx.2 series
95012.1
gr' / Ib
Pxxx 5 series
770/1.7 1 930/2.65 j
930/2.05
gr / Ib
Input Connector
MC4 Compatible
Output Wire Type / Connector I
Double Insulated; Amphenol
Output Wire Length )
0.95/3.0 l 1.2/3.9
m /ft
Operating Temperature Range
-40 -+85 / -40 -+185
'C/'F
1
j Pxxx-2 series
IP65 / NEMA4
Protection Rating
Pxxx-5 series
IP68 / NEMA6P
Relative Humidity I
0-100
%
Rated STC power of the module. Module of up to+;%power tolerance allowed
PV SYSTEM DESIGN USING
SINGLE PHASE THREE PHASE 208V THREE PHASE 480V
A SOLAREDGE INVERTER("
Minimum String Length i
8 10
18
(
(Power OptlmizerO
Maximum String Length
25 25
50
t
(Power Optimizers)
Maximum Power per String
5250 6000
12750
W
Parallel Strings of Different Lengths
or Orientations
Yes
'n It is not allowed to mlx P405 with P300/P400/P600/P700 in one string
4.
RAIN
13USTER
I
�J -r- ty
dVarr
an
p etWoe
Ultra Flexible Roof Tile Adhesive/Sealant
pmdeaf�o Ocag demft aneg flim n We
ROOF TILE 1 SHINGLES I SHEET METAL 1 FLASHING I VENTS I GUTTERS 1 TRIM 1 NEW CONSTRUCTION I REPAIRS
Roofs are on the front line in preventing water intrusion
p High -Grade Polyurethane Formulation
and are subjected to the most extreme wind and weather
D Permanently Secures Roof Tile
conditions. To prevent roof damage and leaks, an adhesive/
D Non -Shrinking, Permanently Flexible
sealant must be a standout performer. RainBuster 850
Ultra -Flexible Roof Tile Adhesive/Sealant is specified by
I> UV Resistant; Flexes to Prevent Broken Tiles
leading builders and trusted by quality -minded contractors
D Withstands Extreme Wind, and Foot Traffic
to prevent roof leaks. Unlike traditional roofing cements.
D Seals Roofing Joints including Flashing
and mastics, RainBuster 850 offers a high-grade polyurethane
b Withstands Extreme Weather & Temperature
formulation, permanent flexibility and powerful adhesion.
p Non -Sag to Prevent Tile Slip
When used as a roof tile adhesive, RainBuster 850 shines
I> Adheres to Damp Surfaces
as it flexes with hurricane force wind uplift, foot traffic, and
b Paintable (See Painting Section)
seismic activity to prevent broken tiles. When applied to
> Non -Flammable
flashing, vents and gutters, RainBuster 850 permanently
b VOC, CARE, and AOMD Compliant
seals joints to effectively divert water away from the home.
D Lifetime Warranty
The Ultimate Roof Tile
$0 : c 01
RICH
BUSTER!
i • • IrC1�l�aE:JI, � ❑ � � Irt��^JCd:� Qt.�i3 � r [[ob • � � o : i � � iD�ri1 ❑ 1�1R,ri! _.;! � .n�iiF.li,v�
DESCRIPTION
RainBuster 850 Ultra -Flexible Roof Tile Adhesive/Sealant
is the high quality standard in the prevention of roof
leaks. Its technologically advanced polyurethane formu-
lation has been specifically designed to provide roofing
application solutions. RainBuster 850 performs equally
well when used as a file adhesive or as a sealant on
flashing, vents, and other roof penetrations. RainBuster
850 is ideal for specifying as a multi -use roofing adhe-
sive/sealant. R is ideal for both new construction and
repairs.
PACIlAGING, SHELF LIFE & STORAGE
RainBuster 850 Ultra -Flexible Roof Tile Adhesive/
Sealant is available in standard 300 ml cartridges
(packaged 24 per case) and 592 ml sausage tubes
(packaged 12 per case). The shelf life is 12 months.
Store in a cool, dry place below 80°F for maximum
shelf life.
AVAILAB&ITYAND COST
RainBuster 850 Ultra -Flexible Roof Tile Adhesive/
Sealant is competitively priced and widely available.
Please contact Top Industrial, Inc. at 800-473-1617 or
see www.topindustrial.com for a supplier nearest you. }
AUTHORIZATIONS
Meets or exceeds:
ASTM C920 Type S, Grade NS, Class 35, use NT, A and M '
Federal Specification TT -S -00230C (COM-NBS)
Type ll, Class A
Canadian Specification CAN/CGSB-19,13-M87
ENVIRONMENTALLY FRIENDLY
• Qualifies for TEED Credit from U.S. Green Building
Council:1 pt EQ Credit 4.13
• Qualifies for NAHB Green Build Credits:
5 pts Global Impact Credit 7.1.3
• VOC Compliant under AGMD and CARB
LIFETIME WARRANTY
Top Industrial warrants this adhesive to perform as
described on its package and associated data sheet for
a period of 100 years from the date of purchase. See
next page for further warranty details.
Field Proven to Prevent Roof Leaks
o TILE -TO -TILE BONDING
RainBuster 850 is ideal for adhering roof file -to -
tile in valley, ridge, hip, rake and general roof tile
installation. Secures cut tiles when mechanical
fasteners cannot be used. RainBuster 850 provides
,+ additional protection against wind uplift, seismic
activity, and tile damage. Prevents file chatter.
D RainBuster 850 seals nail entry points created
rr-n during file installation. RainBuster 850 flexes to
•: stay bonded and prevent broken fife and roof leaks.
FLASHING LAP JOINTS
RainBuster 860 is Ideal for sealing varied lap joirds
where two lengths of flashing meet such as In valleys.
RainBuster 850 flexes to maintain a permanently
bonded watertight seal. For best results, apply a
continuous 1/2" bead to both the inside and
outside of the joint Tool the outside joint bead
as necessary (see application and tooling sec -
tons). Available in the multiple colors and
paintable (see painting section).
I . AOOF-TO-WALL FLASHINGS
RainBuster 850 is ideal for use where flashing
" terminates at walls and chimneys. RainBuster 850
' provides outstanding adhesion to both metal and
common exterior wall surfaces. RainBuster 850
ilexes to maintain a watertight seal. For best
mg results, apply a continuous 1/2' bead to both
-,• c the inside and outside of the joint Tool the out-
side joint bead as necessary (see application
and tooling sections). Available in the multiple colors
and palntable (see painting section).
VENTS AND CHIMNEY CAPS
/ • RainBuster 850 seals joints in verde, chimney caps
and other roofing envelope penetrations. Also secures
vent structures to underlying bm& RainBuster 850
flexes to maintain a watertight seal. For best results.
apply a continuous 1/2" bead to both the inside
and outside of the joint Tool the outside joint
bead as necessary (see application and tooling
asections). Available in the multiple colors and
` q paintable (see painting section).
d±oMw Seals seams in gutters, gutter assemblies, and downspouts.
AUVaNWw#W>NVW Adheres shingles and supplements mechanical fasteners.
Sbl"W Permanently seats seams and fastener entry holes.
~Supplements mechanical fasteners and seals seams. Can significantly reduce vibration noise.
0 tole entSeals tears in felt and undalaymerd. Bridge entire fear and tad as necessary.
Ydf Smftw Lm* &pr .Adheres to to damp surfaces. Remove standing wafer prior to application.
Top Industrial, Inc. 9 15010 Keswick St., Van Nuys, CA 91405 • 800-473-1617 • www:topindustrial.com
u
APPLICATION: Easy to apply with conventional caulking equipment. Application temperature range: 20F —120F. If application air temperatures are below 40F, con-
dition product at 70F prior to using for best results. Cut tip at a 45 -degree angle. Location of cwt will determine desired bead thickness. Puncture seal. Apply sealant to joint.
Typically, minimum 3/8"-1/2" beads should be used for proper bonding and sealing. Fill joints in continuous beads from deepest point and avoid overlapping of sealant to
prevent air entrapment. Adhesive/sealant should wet the joint wall surfaces. With lap joints, apply adhesive/sealant to both inside and outside of joint for best results.
Adhesive/sealant provides 1-3 hour working time before skinning. Adhesivelsealant cures with exposure to normal atmospheric moisture with full cure in 1-3 days depending
on humidity. May be used on damp surfaces; take steps to remove standing water. For best results, use opened cartridges and sausages the same day.
APPROPRIATE SURFACES: RainBuster 850
is appropriate for use in new construction
and repairs on a wide range of common
roofing materials including concrete, clay,
slate, composition, fiber -cement, asphalt
saturated shingles, masonry, mortar, metals
Including galvanized, aluminum, and
copper, underlayment and fells, plastics
including PVC, vinyl, fiberglass, nails, and
wad.
PREPARATION: For best adhesion results,
surfaces should be dean, and free from
dirt, dust, oils, release ager% standing
water, old sealants, or other contaminants.
Dust and lows particles should be blown
oft surfaces.
FIELD PRETEST: Due to the varied nature
of construction substrates, field-test
adhesive/sealant on actual surfaces prior
to beginning work User must determine 4
result including adhesion are acceptable.
TO01i I required, tooling is recommended
within 20 minutes after application. Tooling
should be done in one continuous stroke.
Techniques using solvents or soaps are not
recommended. If masking, remove tape
Immediately after tooting.
CLEAN UP: Clean hands safely with
RainBuster Top Towels (citrus wipes).
Mlneral spirits and other commercial
solvents such as xylene, toluene, or
methyl ethyl ketone (ME)Q may be used
to clean up excess smears and tools. The
use of solvents may be hazardous to your
health. Keep away from open flame and
use In well -ventilated area. Follow
solvent manufacturer's Instructions.
Cured adhestve/sealant is difficult to
remove and must be done so by abrasion
or other mechanical means.
PAINTING OVER RAINBUSTER 850: For
best results, apply paint over RalnBuster
850 adhesive/sealant 72 hours atter
application. High quality 100% acrylic
paints and primers are recommended.
Many roofing specific spray paints are
acceptable. Avoid the use of oil base
paints as they may exhibit a slow/non-
curing condition when in contact with
adhesive/sealant. Paint when weather
and temperature conditions meet paint
manufacturer requirements. Feld pre-test
for suitability of paint and painting
process is required. Contractor must
determine suitability. Consult Top
Industrial for further information.
MAINTENANCE No maintenance should
be needed. If adhesive/sealant becomes
damaged, remove damaged portion. Clean
surfaces in damaged area, and repair with
fresh RainBuster 850.
PRIMING PRIOR TO APPLICATION:
Generally, priming is not required. If
adhesion pretest is unacceptable, consult
Top industrial for recommendations.
APPLICATION OVER GLAZED, PRE-
PAINTED, OR PRE -PRIMED SURFACES:
Glazed, pre -painted and pre -primed
surfaces typically do not -have the adhesive
quality or flexibility of RainBuster 850
adhesive/sealant. Lack of adhesive/sealant
contact with raw substrate may inhibit
ability to maintain bond and seal. Glaze,
paint or primer may pug away from raw
substrate with joint movement.
USE WITH ASPHALT BASED SELF -
ADHERED FLASHING (A.K.A. SBS modi-
fied asphalt & bituminous material):
When used appropriately, RainBuster 850
Can be used successfully with asphalt -
based flashings. Unlimited contact is
acceptable between adhesive/sealant
and the permanent polyethylene/plastic-
based facer side of self -adhered asphalt
flashings. Steps must be taken to minimize
contact with the adhesive side of asphaft
flashings. Plasticizers in adhesive/sealant
may accelerate the normal moistening and
softening of asphalt that occurs with heat.
Do not apply adhesive/sealant directly to
adhesive asphalt side of flashing. Do not
apply adhesive side of asphalt flashing
directly over adhesive/sealant. Remove
excess sealant prior to application of
adhesive asphalt side of flashing. User
must determine suitability through field
pretest. Consult Top Industrial for further
information.
LIMITATIONS: Suitability for each intended
use must be determined by the user using
the Information found in this data sheet and
an application pretest
• Not for use over standing surface water
or Surface frost
• Not designed to replace use of
mechanical fasteners.
• Not for use where subjected to constant
water immersion.
• When painted, user must determine
paint suitability. See"Painting" section for
detailed limitations.
• When used with asphalt -based self -
adhered flashings, user must determine
suitability through field pretest See 'Use
With Asphalt" section for detailed
limitations.
• Do not cure in presence of curing
silicone sealants. This may interfere
with RainBuster850's curing,process.
• Avoid sealant contact with solvent
cleaners during are. This may interfere
with RainBuster 850's curing process.
PRECAUTION: Combustible vapor.
Uncured sealant may rause allergic skin
reaction and eye, skin and respiratory tract
Irritation. Keep away from sparks and
flame. Avoid contact with eyes, skin and
clothing. Avoid prolonged exposure to
vapors. Use only with adequate ventilation.
Wear protectve clothing during handling.
Wash thoroughly after handling. KEEP OUT
OF REACH OF CHILDREN. See material
safety data sheet before use (contact Top
Industrial or distributor).
FOR CONSiRUC710M AND INDUSTRIAL
USE BY QUALIFIED CRAFTSMAN.
FIRST AID: If inhaled, rernoveto fresh air.
N breathing is difficult, give oxygen and call
a physician. In case of contact with
uncured sealant, immediately flush eyes
with water for at least 15 minutes and
wash skin with soap and water after using
RainBuster Top Towels (dbts wipes). Call a
physician if inflation persist. See material
safety data sheet for more detail..
LIFETIME WARRANTY DETAILS: Top
Industrial, Inc. warrants this sealant/adhe-
sive to perform as described on its pack-
age and associated data sheet for a period
of 100 years iron the date of purchase.
Upon proof of purchase, Top Industrial's
sole liability, expressed or implied, shall be
to replace sealant/adhesive proven defec-
tive and is limited to the stated selling
price. This warranty is not transferable
from the original purchaser. in no event
shall Top Industrial be gable for conse-
quential or incidental damages, resuf ing
from the use of its sealant products.
0 iY 0
BUSTER
• �:�e.� aft:-�_--
-v•
��A r
�• � � lL
d{ v
Top Industrial, Inc. • 15010 Keswick St., Van Nuys, CA 91405 • 800-473-1617 • www:topindustrial.com
RAIN�
BUSTER
The Ultimate
Roof Tile
Adhesive/
Sealant
Ultra Flexible Roof Tile Adhesive/Sealant
Prevents Roof Leaks and Broken Tile
ROOF TILE I SHINGLES I SHEET METAL 1 RASNM I VENTS I OUITERS I TRIM I NEW CONSTRUCTION I WAIWS
AVAILABLE COLORS
Coral Tena Cotta Tan Gray (Sloane) Brown Black
(BMW)
I
BIP.
For more than 25 years,
Top Industrial's RainBuster
I has been trusted to prevent leaks in the building
elope and squeaks in floor structures. Today that
ist runs deep - RainBuster is specified by the
radon's leading builders and trusted by scores of
900 ML CARTRIDGES
The reason for the trust is simple...
RalnBuster products and services outperform
APPROMMATE LINEAR FEET PER CARTRIDGE
related call-backs.
w
BEAD WIDTH, INCHES
114" aw 1/2' 318"
3/4"
7/8"
1"
..
1/8'
49.6 33.1 24.8 20:0
16.5
14.2
12.4
1/4'
24.8 20.0 12.4 10.0
8.3
7.1
6.2
a
-
3/8'
- 11.0 8.3 6.6
5.5
4.7
4.1
112"
- - 6.2 5.0
4.1
3.5
3.1
Ro"dly
th� usn
PHYSICAL PROPEIMES
Skin Time..........................................................1-3 hours
Cure Time...........................................................1-3 days
% solids.......................................................96% to 99%
Pairdabie.........................................Yes — See limitations
Sag or Slump...........................................................None
Clean-Up....................................................Citrus Cleaner
Shrinkage....................................................................NII
Chalking or Crazing., ....... . ...... ....... I ........ . .. . . ........ Nil
11PICAL PERFORIHAMCE CHARACTERISTICS
After 7 days cure at 77 deg. F and 50% RH
Hardness (Shore A); ................................ 32 ASTM D 2240
Tensile Strength ......................Up to 250 psi ASTM D 412
Elongation ... ..................................... 1400%ASTM D 412
Adhesion in Peel..................................................>33 piw
...........................................T-S-00230C/ASTM C 794
Stain & Color Change................................................None
.......................TT-S-002300
STM C 510
Ozone Resistance ...............................................Excellent
Joint Movement Capability ..................................... ±35%
ASTM C719, 73"F cure / 73°F cycling
W Resistance ........................Excellent - ASTM C 793-75
Water Resistance ................................................Excellent
BIP.
For more than 25 years,
Top Industrial's RainBuster
I has been trusted to prevent leaks in the building
elope and squeaks in floor structures. Today that
ist runs deep - RainBuster is specified by the
radon's leading builders and trusted by scores of
respected contractors.
The reason for the trust is simple...
RalnBuster products and services outperform
other brands in preventing leak and squeak
related call-backs.
w
�o
Product Data Sheet DU222RB
Safety Switch, 60A, 240VAC, Non -Fusible,
General Duty, 2 -Pole
I]
Technical Characteristics
Wire Size
Action
Ampere Rating
Approvals -
Enclosure Type
Enclosure Rating
Factory Installed Neutral
Maximum Voltage Rating
Disconnect Type
Terminal Type
Mounting Type
Type of Duty
Number of Poles
Shipping and Ordering
_BCWARE' 32
by Sehneider eicctric
List Price $353.00 USD
Availability Stock Item: This Item Is normally stocked in our distribution facility.
#10 to #2 AWG(AI) - #14 to #2 AWG(Cu)
Single Throw
60A
UL Listed File Number E2875
Rainproof and SteeUlce proof (Indoor/Outdoor)
NEMA 3R
No
240VAC
Non -Fusible
Lugs
Surface
General Duty
2 -Pole
Category
00106 - Safety Switch, General Duty, 30 - 200 Amp, NEMA3R
Discount Schedule
DE1A
GTIN
00785901491491
Package Quantity
1
Weight
4.7 lbs.
Availability Code
Stock Item: This item is normally stocked in our distribution facility.
Returnability
Y
Country of Origin
MX
As standards, specifications, and designs change from time to time, please ask for confirmation of the information given in this document.
Q 2009 Schneider Electric. All rights reserved. Schneider
VElectric
NEW PV SOLAR SYSTEM
N
s
FOR
{. ,..
xr } _ -
CD
U to
;t
CD
�
�'
Breitigan Residence
. ..
,F
4
N
Q m
r
-o O Z
LOCATED AT
..#
E c6
-°
co <
53455 Avenida Alvarado
-_
-
J
LaQuinta, CA 92253
---
so ar
�
APN # 604-311-005
"
GOVERNING CODES
SHEET INDEX
o
ALL WORK SHALL COMPLY WITH THE CODES BELOW
-
COVER SHEET
N
c4
J
All construction shall comply with the 2013 California Buiding, Residential, Mechanical,
P.V. 1.0
SITE PLAN
"01111`
11 of Ca,''''1
"
Electrical, Plumbing, Energy and Green Building Codes and La Quinta Municipal Code
CD
co
2.0
�' °"e�� c-' : _
P.V.
ROOF PLAN
��� -
o
°'
�O
U)
P.V. 3.0
e .
MOUNTING DETAILS��°•?'� 9t3�5`°,�'oi��
Q
o
F
>_
W
LO
eoe so°e•°°
Uj
H
W
E. 1.0
1 -LINE DIAGRAM "'"`
o"
LL
W
J
J
Z
J
�—Q
J
Q
CITY FLAQUINTA
—�zZzdo
_
BUILDING & SAFETY DEPT.
SHEET
NAME:
APPROVEU
W W
FOR CONSTRUCTION
> W
•
DATEJWsY
�U
O
(n
SHEET
"CLASS "A" FIRE RATED MODULES AND RACKING SYSTEMS REQUIRED PER
I V"
NUMBER:
U.L. 1703 AND CSFM 14-011"
Photovoltaic equipment and systems and all associated wiring and interconnections shall be installed
'
only by qualified persons. CEC 690.4
-0
d
'.
� 1
Roof Section 2
Roof Azimuth: 0
Roof Tilt 14
S -CURVE TILE
Roof Section 1
Roof Azimuth: 180
Roof Tift: 14
S -CURVE TILE
BOL KEY:
0 PLUMBING VENTS)
ROOF VENT(S)
CHIMNEY
SKY LIGHT(S)
SATELLITE
DISH
I ELECTRICAL MAST
ROOFTOP
vw SWAMP COOLER
ACROOFTOP
ROOFTOP AC UNIT
Roof Section 4
RodAzrnLM:90
Rod Tit 14
S -CURVE TILE
1 9"
. . .
. . .
.....................
. . . .............................
. . . ............................. .
...............................
...............................
. ................
...... .... ..
. . .
.................................
.... ................................................................
.................................
............. I ................
...............................
................
........................
............................
.... .....................................................
........ ............................
...........................
......... ............................
..........................................................
............................
. . . . ...........................
...........................
.........................
.............................
...............................
.............................
..............................
..............................
............................
CITY OF LA QUINTA
.PPILDING & SAFETY DEPT.
APPROVED
FOR CONSTRUCTION
DATE BY
Roof Section 6
RoafAvrvuth: 0
Roof Tilt 14
S -CURVE TILE
Roof Section 5
Roof Azimuth: 180
Roof Titt: 14
S -CURVE TILE
SHEET
NAME:
..........
...........
LL Z
..........
...........
0
0<
..........
...........
..........
...........
.......... ()f
EXISTING CONDUIT PV SYSTEM ROOF PLAN CD
® ® TIE INTO UTILITY METER #
M 1113" = V —01' >
I a—
o 0
'o
C
An a
M
cn c Z
f
m
0 a o C
O� a
< v
D m
0 y Z
O 00
�D >0< O
r mv
G) � + m-nvc to
Om
z �C
O
C < _°T
o Ty
m C7 r Cl) m7 D ~ Z m 0
Z � Z 0 m O0�
cnU) G)u 00
�m
O D D v -� 0 w
0.V
o
Z7 z m
G) m00
z
Dz
m z �Z
x
_ X Cn
Cn
m
r
Z O Z
0K0m (nor- Z
Cn OOn -0
D r -Dy ZK�
M --j U) G)
m mZ 000 0 Dn AW N
0 K O C D o�-�=
C D D r- rPzOz
m-i� Z = + ;a
W G) m nm0m
M Z Z u k.6
�o
-i mo�z°m n°��
DOr(AC chi Nm
G A N�
pi�mw
zm q m m
55=m m
2 p 3
R,
M C�
0 z 1'I
o� a�
z c> m ``o
m
tDi� O
rm D -O
Z �O 0'c
O < m -4 �m
0,9 -4O yO
C m n
m :r
:Ey
O
0 � O z O
D o O
r (n C m m Z m
m r pm �D O�m
m
z_
0 m r "' m 0.
W Vir-x
D r, Vi NmG)
C ,x;161 i ZTw
Q m x O 5
z
0-4m
Ory
m m...
z 1
0 0_ 0_ '
mm 41m �m
1 p7 PQ
O. A 1
D?0 Nu
n go
0 C)� G) n
O = O nD
_a C 0--j
� a p � 2 1/2" MIN.
F- O r v°' °D
mO Z -u D <
O go Q0 m
leBro�s��Zv o I W tib
D n D O a O� I N
t a x_
m, (zr)e mG) m n m I mGzi
x-� .. ! "•n .n
ec�n o 4 Gn r
CALIFORNIA C-46# - 973756
NAME -CODY ORAM t
c
m D = INSTALLER: VIVINT SOLAR Breltlgan Residence
m MOUNT. M m INSTALLER NUMBER: 1.877.404.4129 vivintsolar
w m m • 53455 Avenida Alvarado
PV 3.0 m --i --ICA LICENSE: 973756 (C46/C10) La Quinta, CA 92253
DETAILS DRAWN BY: TMK I S: 4790081 1 Last Modified: 2/11/2016 UTILITY ACCOUNT NUMBER: 50664871
35 PV MODULES PER INVERTER =9100 WATTS STC
1 STRING OF 17 PV MODULES
1 STRING OF 18 PV MODULES
Q O Q o 0 0 18 17
SOLAREDGE gym—�—
P300 OPTIMIZERS
0 0 0 ° ° ° 17 ,B
H0 0 0 = �,
SOLAREDGE I
P300 OPTIMIZERS
* CONFORMS TO ANSI C12.1-2008
Conduit Conductor Schedule (ALL CONDUCTORS MUST BE COPPER)
Tag #
Description
Wire
Gauge
# of Conductors/Color
Conduit
Type
Conduit
Size
1
PV Wire
10 AWG
2 (V+, V-)
N/A -Free
Air
N/A -Free
Air
1
Bare Copper Ground (EGC/GEC)
6 AWG
1 BARE
N/A -Free
Air
N/A -Free
Air
2
THWN-2
8 AWG
4 (2V+, 2V-) R/B
EMT
3/4"
2
THWN-2 - Ground
8 AWG
1 GRN
EMT
3/4"
3
THWN-2
8 AWG
3 (11-1, 1L2 1N) B/R/W
EMT
3/4"
3
THWN-2 - Ground
8 AWG
1 GRN
EMT
3/4"
1 SOLAREDGE
SE760OA-US-R
INVERTER'
L SOLAREDGE
ti DC SAFETY
SWITCH
0 0 0 0
JUNCTION BOX 2
WITH IRREVERSIBLE
GROUND SPLICE
CONFORMS TO NEC 2014
02
POINT OF
a
V5
W
CONNECTION— L1 L2 N
v
N
LOAD SIDE
�? '•:.� ` ;'�':`
C
�o
N
�
M
.
�®
m
v
0
POINT OF
V5
W
CONNECTION— L1 L2 N
LOAD SIDE
�? '•:.� ` ;'�':`
c
NEC 705.12(D)
'S' r..•T'�
O n 1
z o
SquareD#DU222RB 200A
240V/60AUNFUSED
NEMA3
�,�
T-1
Z
OREQUIVALENT
oZc
z J
z M
q
40A
240V/200A AC
SHEET
LOAD -CENTER
NAME:
G
WITH 1-2 POLE 40A
o
VISIBLE
SOLAR BREAKER
2
W
LOCKABLE MINIMUM GEC SIZE
LU
KNIFE' � ^ 4 AWG COPPER
Q Z q
EC
DISCONNECT ,, Jj
—
—
_
J
O -� Q
r
SHEET
NUMBER:
'w
0
Created with Electrical
Template Revision 9/10/15
W
[Design Conditions: I
ROOFTOP CONDUCTOR AMPACITIES DESIGNED
IN COMPLIANCE WITH NEC 690.8, TABLES
310.15(B)(2)(a), 310.15(B)(3)(a), 310.15(B)(3)(c),
310.15(B)(16), CHAPTER 9 TABLE 4, 5, & 9.
LOCATION SPECIFIC TEMPERATURE OBTAINED
FROM ASHRAE 2013 DATA TABLES.
ASHRAE 2013
Highest Monthly 2% DB Design Temp 47°C.
Lowest Min. Mean Extreme DB -7.5°C
DC Safety Switch:
Rated for max operating condition of
inverter NEC 690.35 compliant
*opens all ungrounded conductors
Calculations:
Breaker, calculations dependent upon inverter Continuous Maximum Output.
Wire Gauge Calculated from NEC code 310.15(B)(16) with ambient temperature calculations from NEC
310.15(2)(a) using the 90*C column (On Roof) or 75*C column (Off Roof), *310.15(B)(3)(c) for 1/2" minimum
clearance of the conduit above the roof and 310.15(B)(3)(a) Adjustment factor for current -carrying cunductors
in a raceway.
- When a wire is upsized in the conduit conductor table, voltage drop adjustments were made
SE760OA-US-U Max Output = 31.67A x 1.25 (NEC code 210.19(A)(1)(a))=39.60A.
(off roof): 8 gauge wire rated for 50A > 39.60A (max of solar panel production).
(on roof): 8 gauge wire rated for 55A x 0.50 (ambient+*22°C) x 0.800000 (fill derate of 4 current -carrying conductors)
= 22.00 > 18.75A Max circuit output per circuit 15 x continuous duty uprating 125%).
System SDecs:
Max DC Voltage
Nominal DC Operating Voltage
Max. DC Current per String
Nominal AC Current
500V
350V
15A
47.5A
PV Module Rating @ STC
Model Make/Model
YL260P-29b
Amps
Max Power -Point Current (Imp)
8.59
Amps
Max Power -Point Voltage (Vmp)
30.3
Volts
Open -Circuit Voltage (Voc)
37.7
Volts
Short -Circuit Current (Isc)
9.09
Amps
Max Series Fuse (OCPD)
15
Amps
Nominal Maximum Power at STC (Pmax)
260
Watts
Maximum System Voltage
1000 V (IEC) / 600 V (UL)
Volts
Voc Temperature Coefficient
-0.32
%/C
Other Notes
Solar PV System AC Point Of Connection
AC Output Current
Accoding to Nec
690.8(B)(1)
39.6
Amps
Nominal AC Voltage
240
Volts
THIS PANEL IS FED BY MULTIPLE SOURCES (UTILITY AND SOLAR)
Optimizer
Solar Edge P300
DC Input Power
300
Watts
DC Max Input Voltage
8-48
Volts
DC Max Input Current
12.5
Amps
DC Max Output Current
15
Amps
Max String Rating
5250
Watts
Inverter Make/Model
SE760OA-US
CEC Efficiency
97.5
%
AC Operating Voltage
240
Volts
Continuous Max Output Current
32
Amps
DC Maximum Input Current
23
Amps
Short Circuit Current
40
Amps
Max Output Fault Current
40
A/20ms
CITY OF LA QUINTA
BUILDING & SAFETY DEPT.
APPROVED
FOR CONSTRUCTION r
DATE BY
\V • • nr
...u`.J-
_M
02
a
N
M
�s 6
J
a
V
s
J
s
SHEET
NAME:
W
It W
gZq
0J Q
V) •' O
SHEET
NUMBER:
O
W
INVERTER GROUNDED SYSTEMS PER 690.5(C)I]
LNPHASt: AI J-t$UXtJ
WARNING
ELECTRICAL SHOCK HAZARD
IF A GROUND FAULT IS INDICATED,
NORMALLY GROUNDED CONDUCTORS
MAY BE UNGROUNDED AND ENERGIZED
COMBINER BOXES, J -BOXES, DISCONNECTS, DEVICES &
INVERTERS IN UN -GROUNDED SYSTEMS PER 690.35(F)
(STRING SYSTEMS)
WARNING
ELECTRICAL SHOCK HAZARD.
THE DC CONDUCTORS OF THIS
PHOTOVOLTAIC SYSTEM ARE UNGROUNDED
AND MAY BE ENERGIZED
CONDUIT AND RACEWAYS (LABELED EVERY 10')
WARNING: PHOTOVOLTAIC POWER SOURCE
DC DISCONNECT PER 690.17 & 690.53
SOLAR DC DISCONNECT
WARNING
ELECTRICAL SHOCK HAZARD.
DO NOT TOUCH TERMINALS. TERMINALS
ON BOTH THE UNE AND LOAD SIDES
MAY BE ENERGIZED IN THE OPEN POSITION
PHOTOVOLTAIC POWER SOURCE DC DISCONNECT
RATED MAXIMUM POWER POINT CURRENT (IMP) 8.59 A
RATED MAXIMUM POWER POINT CURRENT (VMP) 30.3 A
MAXIMUM SYSTEM VOLTAGE (VOC) 37.7 V
SHORT CIRCUIT CURRENT (ISC) 9.09 A
DERATE OF MAIN BREAKER DUE TO SOLAR
MAIN BREAKER DE -RATED DUE TO SOLAR CIRCUITS
AMPS MAX ALLOWED
DO NOT UPGRADE
NOTE: SIGNAGE CHARACTERISTICS - MIN. 3/8, REFLECTIVE, WHITE, ARIAL, ALL CAPITAL
LETTERING ON RED BACKGROUND MADE OF WEATHER RESISTANT MATERIAL.
AC DISCONNECT AND ANY LOAD CENTERS
(COMBINER PANEL) PER 690.17(E) & 705.12
SOLAR AC DISCONNECT
PHOTOVOLTAIC AC DISCONNECT
RATED AC OUTPUT CURRENT: 39.6 A
NOM. OPERATING AC VOLTAGE: 240 V
WARNING
ELECTRICAL SHOCK HAZARD.
DO NOT TOUCH TERMINALS. TERMINALS
ON BOTH THE LINE AND LOAD SIDES
MAY BE ENERGIZED IN THE OPEN POSITION
INVERTER OUTPUT CONNECTION (SOLAR BREAKER)
AT MAIN SERVICE PANEL PER 705.12
WARNING
INVERTER OUTPUT CONNECTION
DO NOT RELOCATE THIS
OVERCURRENTDEVICE
MAIN SERVICE PANEL SIGNAGE
(INSTALLED ON THE FACE OF THE SERVICE METER)
PER 690.54, 690.56(8) & 705.10 NOTE: Roofline Placard not needed
unless PV disconnect is not at same location as Main Service
CAUTION: SOLAR ELECTRICAL SYSTEM CONNECTED
ER TO THIS
6 FRTHE Fa
`��l�Y • ONN Y
PHOTOVOLTAIC POWER SOURCE
RATED AC OUTPUT: 39.6 A
NOM. OPERATING AC VOLTAGE: 240 V
SERVICE
CI OF LA QUINT'A
BU WING & SAFETY DEPT.
PPROVE®
OR CONSTRUCTION
4e4c�taee><ua���,�
eke a° �Q �c �1 oe� �• ''�
°
o v
T!, °e o° .
o� ' ao J737'0Av
� °Oo�0000•#a°� G� ��
0
v -°
U L
c M
6J >
Q
v
m _
c c
M
OD >
}, m
to
v Ln
CO m
Ln
F,
0
(A0
0
Ln66
N
N t0
rn m
Q O
u "'
" u
c Q
C
J �I
rn
N
v !
o
w
U
n oi3 u
C9 tD t
O u c
W c
Z W t!! Y
Z m n
_> m
z 01
Z
OC d' to
J J Z
J J W O
V_ O
Cn
N Ln J N
v
zz<U
SHEET
NAME:
W
Q
Q
Z
0
N
(SHEET
NUMBER:
T-4
r4
J
C
d .e
EVERY 10'
AND WITHIN 1'
OF ELBOWS
STRING -INVERTER
SYSTEMS
(7 _
10:
STRING -INVERTER
SYSTEMS
D
WARNING
CAUTION: SOLAR ELECTRIC SYSTEM CONNECTED PHOTOVOLTAIC DISCONNECT ELECTRICAL SHOCK HAZARD
Property of Vivint Solar3
of Vivint Solar THE DC CONDUCTORS OF THIS �__
RATED AC OUTPUT CURRENT: 39.6 A 10 PHOTOVOLTAIC SYSTEM ARE UNGROUNDED
MAIN BREAKER DE -RATED DUE TO SOLAR CIRCUITS NOM. OPERATING AC VOLTAGE: 240 V AND MAY BE ENERGIZED
2 AMPS MAX ALLOWED — it SOLAR DC DISCONNECT
DO NOT UPGRADE WARNING Property of Vivint Solar°; A
in co
Property of Vivint Solar ELECTRICAL SHOCK HAZARD. - a N ,�,
DO NOT TOUCH TERMINALS. TERMINALS SOLAR DC DISCONNECT a °' w
7 ON BOTH THE LINE AND LOAD SIDES 1 Property of Vivint So u u R
--,\ PHOTOVOLTAIC POWER SOURCE MAY BE ENERGIZED IN THE OPEN POSITION c w 2
3Property of Vivint Solar Pro ert of Vivint Solar m > <
RATED AC OUTPUT: 39.6 A PHOTOVOLTAIC POWER SOURCE DC DISCONNECT v _
Ln
NOM. OPERATING AC VOLTAGE: 240 V r CAUTION: SOLAR CIRCUIT - RATED MAXIMUM POWER POINT CURRENT (IMP) 8.59 A mrn
V Property of Vivint Solar 12 RATED MAXIMUM POWER POINT CURRENT (VMP) 30.3 A '^
MAXIMUM SYSTEM VOLTAGE (VOC) 37.7 V
WARNING SHORT CIRCUIT CURRENT (ISC) 9.09 A
D-4INVERTER OUTPUT CONNECTION WARNING Pro a of Vivint Solar
DO NOT RELOCATE OVERCURRENT DEVICE ELECTRICAL SHOCK HAZARD
IF A GROUND FAULT IS INDICATED SITE PLAN PLACARD SHOWING ADDITIONAL POWER
5 PHOTOVOLTAIC NORMALLY GROUNDED CONDUCTORS 13 SOURCE AND DISCONNECT LOCATIONS. PLACARD
AC DISCONNECT Y MAY BE UNGROUNDED AND ENERGIZED SHALL BE MOUNTED ON EXTERIOR OF ELECTRICAL
i
Property of Vivint Solar PANEL(only when necessary)L
CITU OF LA QUINTA
BUILDING & SAFETY DEPT. 0
APPROVE® cn
12, FOR CONSTRUCTION 13
IF APPLICABLE c
DATE BY N
11 7 7 7 3 �z„ct�la�,AaILI
°••
C.1
^� G
ROOFTOP ARRAY (10
7
.0
OSOLAR
O0�F���`� INVERTERS
O,o,�iO l
' 71h' eA1' vidl; 1QN„ :V4k 'A`i�'k s)4
DC
DISCONNECT
INSIDE
6) (6
Am' vw,
!UNCTION �Q INTEGRATED WITH ARRAY)
BOX +
)MBINER VISIBLE/LOCKABLE � SUB PANEL
PANEL A/C DISCONNECT VIVINT SOLAR METER VISIBLE/LOCKABLE
(WHERE. -REQUIRED) A/C DISCONNECT (WHEN
(WHERE REQUIRED) REQUIRED)
TYPICAL SOLAR GENERATION INSTALLATION
(NOT ALL DEVICES ARE REQUIRED IN EVERY JURISDICTION) ,4 INSIDE PANEL
THESE PLACARDS SHALL BE PLACED ON ALL INTERIOR AND EXTERIOR DIRECT-CURRENT (DC) CONDUIT, ENCLOSURES.
ALL STICKER DESCRIBED HERIN SHALL BE MADE OF A WEATHER PROOF ADHESIVE, THEY SHALL BE REFLECTIVE, REALE-WAYS, CABLE ASSEMBLIES,JUNCTION BOXES, COMBINER BOXES, AND DISCONNECTS TO ALERT THE FIRESERVICE IX
AVOID CUTTING THEM. MARKINGS SHALL BE PLACED ON ALL DC CONDUIT EVERY 10 FT (3048 MM), WITHIN I FOOT (305
THEY SHALL CONTAIN NO SMALLER THAN 3/8” WHITE ARIAL FONT TEXT, AND HAVE A RED BACKGROUND MM) OF TURNS OR BENDS AND WITHIN I FOOT (305M.M). ABOVE AND BELOW PENFTRATIONSOFROORCEILING
ASSEMBLIES, WALLS OR BARRIERS
2
H
�°
` 44(0 .` e�G ,
O
ON
N
c
�qco p� Zgv_
~
n
Y
Z
co
�
u
�0psaaoee°yr
O^1
m
��
`�s
&
00
-4
U
L
v
m
DISCONNECT
- PANE'
4
INSIDE PAN
ON
c
~
n
Y
Z
co
�
m
O^1
m
&
Z
w
N
ei
W
J
W
J
Z
W
00
O
O
N
N
U
J
cn
K
z
SHEET
NAME:
caO
N
z
W
m
I=
Q
g
3
i�@gaIOIlleee�ef,
SHEET
NUMBER:
O
. Sfl S
o
POWER TO THIS BUILDING IS ALSO
SUPPLIED FROM THE FOLLOWING
SOURCES WITH DISCONNECTS AS SHOWN
N
JUNCTION BOX
LOCATED ON ROOFTOP
SOLAR MODULES WITH POWER
)PTIMIZERS MOUNTED ON THE
SACK OF EACH MODULE
?V INTERCONNECTION POINT,
LOCKABLE DISCONNECT
SWITCH,& UTILITY METER
LOCATION
53455 Avenida Alvarado