Loading...
07879 (SFD)Building Address 51-245 Rubs® Owner Paul 8 Dori Quill Mailing Address 54-390 Obre(M City I Zip ITel. Contractor Address Zip State Lic. I City & Classif. Lic. # Arch., Engr., Designer Address Tel. 44 Ci P.O. BOX 1504No. 7&105 CALLE ESTADO LA QUINTA, CALIFORNIA 92253 City.I ZipI'Stafte I Lic, # I hereby affirm that I.amjlf'ensedeunder provisions�of Chapter 9 (comm nc' g''with Section 7000) of Division 3 o t Ausine sand Profa sionsSCode, aid my li nsai l'h full force and effect. ,t 7% ,+I .y _ / IF OWNER -BUILDER DECLARATION I hereby affirm that I am exempt from the Contractor's License Law for the following reason: (Sec. 7031.5,Business and Professions Code: Any city or county which requires a permit to construct, after, improve, demolish, or repair any structure, prior to its issuance also requires the applicant for such permit to rile a signed statement that he is licensed pursuant to the provisions of the Contractor's License Law, Chapter 9 (commencing with Section 7000) of Division 3 of the Business -and Professions Code, or that. he is exempt therefrom, and the basis for the alleged exemption: Any violation of Section 7031.5 by 'any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500). O I,.as owner of the property, or my employees with wages as their sole. compensation, will do the work, and the structure is not intended or offered for sale. (Sec. 7044, Buisness and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon and who does such work himself or through his own employees, .provided that such Improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he did not build or improve for the purpose of sale.) ❑ I, as owner of the property, am exclusively contracting with licensed contractors to con- struct the project. (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who contracts for such projects with a contractor(s) licensed pursuant to the Contractor's License Law.) ❑ 1 am exempt under Sec. B. & P.C. for this reason Date Owner WORKERS' COMPENSATION DECLARATION I hereby affirm that I have a certificate of consent to self -insure, or a certificate of Worker's Compensation Insurance, or a certified copy thereof. (Sec. 3800, Labor Code.) Policy No. Company ❑ Copy is filed with the city. ❑ Certified copy is hereby furnished. CERTIFICATE OF EXEMPTION FROM WORKERS' COMPENSATION INSURANCE (This section need not be completed if the permit is for one hundred dollars ($100) valuation or less.) I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the Workers' Compensation Laws of California. Date Owner NOTICE TO APPLICANT., If, after making this Certificate of Exemption you. should become subject to the Workers' Compensation provisions of the Labor Code, you must 'forthwith comply with such provisions or this permit shall be deemed revoked. CONSTRUCTION LENDING AGENCY I hereby affirm that there is a construction lending agency for the performance of the work for which this permit is issued. (Sec. 3097, Civil Code.) Lender's Name Lender's Address This is a building permit when properly filled out, signed and validated, and is subject to expiration it work thereunder is suspended for 180 days. I certify that I have read this application -and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter the above- mentioned property for inspection purposes. Signature of applicant Date Mailing Address City, State, Zip LDING: TYPE CONST. OCC: GRP. 0 879 A.P. Number �i�—ca•c�i� ,Legal Description Project Description fie i�i� tots 4 9 5 i1t� F:xrniv til�siltr}n► Sq. Ft. 2550 Size No. Stories - No. Dw. Units New ❑ Add ❑ Alter ❑ Repair ❑ Demolition ❑ Estimated Valuation $150y723 PERMIT AMOUNT Plan Chk. Dep. 250.00 Plan Chk. Bal. 52.65 Const. 83,Ofl Mech. Electrical l" Plumbing S.M.I. 10.99 Grading Driveway Enc. Infrastructure .1629,27 TOTAL 2.023.91 1.773.91 REMARKS .. ,»K-rda-TSA?4 a@k'rttl "'f�i1.=+S ._ r .i t•ii+ Y ZONE: BY: Minimum Setback Distances: Front Setback from Center Line Rear Setback from Rear Poop. Line Side Street Setback from Center Line Side Setback from Property Line FINAL DATE INSPECTOR Issued by: Date 10 90Permit Validated by: Validation: CONSTRUCTION ESTIMATE NO. ELECTRICAL FEES NO. PLUMBING FEES 1ST FL. SO. FT. @ $ 2ND FL. SO. FT. @ POR. SO. FT. ® GAR. SO. FT. ® CAR P. SO. FT. WALL SO. FT. SO. FT. ® ESTIMATED CONSTRUCTION VALUATION $ UNITS MOBILEHOME SVC. POWER OUTLET YARD SPKLR SYSTEM BAR SINK ROOF DRAINS DRAINAGE PIPING DRINKING FOUNTAIN. URINAL WATER PIPING NOTE: Not to be used as property tax valuation SLAB GRADE FLOOR DRAIN MECHANICAL FEES BONDING WATER SOFTENER VENT SYSTEM FAN EVAP.000L HOOD SIGN WASHER(AUTO)(DISH) APPLIANCE DRYER AD SEWER OR SEPTIC TANK RM GARBAGE DISPOSAL FURNACE UNIT WALL FLOOR SUSPENDED DUCT WORK LAUNDRYTRAY AIR HANDLING UNIT CFM n Y KITCHEN SINK ABSORPTION SYSTEM B.T.U. TEMP USE PERMIT SVC WATER CLOSET' COMPRESSOR HP POLE, TEMIPERM LAVATORY HEATING SYSTEM FORCED GRAVITY AMPERES SERV ENT SHOWER BOILER B.T.U. SO. FT. ® c BATH TUB SO. FT. ® c WATER HEATER MAX. HEATER OUTPUT, B.T.U. SO. FT. RESID ® 11/. c SEWAGE DISPOSAL BOND BEAM SO.FT.GAR ® 3/ic HOUSE SEWER $ GAS PIPING PERMIT FEE PERMIT FEE PERMIT FEE DBL TOTAL FEES MICRO FEE MECH.FEE PL.CK.FEE CONST. FEE ELECT. FEE SMI FEE PLUMB. FEE STRUCTURE PLUMBING ELECTRICAL HEATING & AIR COND. SOLAR SETBACK d O BIN UNDERGROUND A.C. UNIT COLL. AREA SLAB GRADE ROUGH PLUMB. 99 BONDING HEATING (ROUGH) 41 STORAGE TANK FORMS AD SEWER OR SEPTIC TANK RM ROUGH WIRING DUCT WORK ROCK STORAGE FOUND. REINF. n Y GAS (ROUGH) METER LOOP HEATING (FINAL) OTHER APPJEOUIP. REINF. STEEL GAS (FINAL) TEMP. POLE p D GROUT WATER HEATER SERVICE FINAL INSP. BOND BEAM WATER SYSTEM $ GRADING cu. yd. —plus—x$_=$ LUMBER GR. FINAL INSP. x// FRAMING FINAL INSP. n_ ROOFING/�(/J� � '� O ,nl/ � ` /�Jl_ /` l / /�/ t/ '��� L /4— /%� / /d 11 Q REMARKS: VENTILATIvO'N" FIRE ZONE ROOFINGC/�e< FIREPLACE SPARK ARRESTOR GAR. FIREWALL LATHING MESH INSULATIONISOUND FINISH GRADING FINAL INSPECTION CERT. OCC. FENCE FINAL INSPECTOR'S SIGNATURES11NITIALS GARDEN WALL FINAL V i I t. y COUNTY OF RIVERSIDE ENVIRONMENTAL AsefteM ftroM Na 'I HEALTH SERVICES DIVISION 1773-191 -017,01N PE.� MlTI•APPUCATLQN FOR A SUBSURFACE SEWAGE DISPOSAL SYSTEM �p nl Appli ani Sub'`mitr (I - f' '.with four copies of a scaled plot plan (1-20 scale) drawn to County speculations as indicated on the attached check list A non-refun`dable filing fee (see below) is required when the application is submitted. Check must be made payable to the County of pU jRfverside. Approval of this application shall remain valid for a period not to exceed one year from date of approval. Z� VERIFY ITEMS IN SECTION A FROM BUILDING & SAFETY APPLICATION BUILDING DEPARTMENT APPLICATION LOG # 01 Agent or, Conte Person G-- Pho Address & Firm (-: ' wn e� c�er Owner Phone Mailing Address 5 o d 6r c cam &a C1,, I City Z-4 r State CA- Zip 22 S Job Property AddLegal 5 2 V 5 7244& r 1 Desc xxr Prop. M, Tract, Lot) 404- y� Blcf-A -*/ Ur .-� Lot Size ter Agency Use of Permit P/P CU, etc. Other '54n/�ar ' O /yR1r'� G f( � a r 4 r � (JI.J�./rep� Dwefli a , etc. Signature of Applicant Date CATEGORY: REV COD CATEGORY: REV CODE FEE 6 SUBSURFACE DISPOSAL 1238 $45 00 ❑ SITE EVALUATION UPON REQUEST 7349 $ 43.00 m ❑ MULTIPLE PARCELS WITHIN SAME (NO PLOT PLAN) LAND DIVISION ❑ SEWER/SEPTIC VERIFICATION 7348 $ 17.00 O 0 a. 1 st 4 Parcels (Each) 1238 $ 57.00 (Less than 1 year) 1b. Each Parcel after 4 7344 $ 24.00 ❑ PRELIMINARY ELECTIVE 7352 $ 23.00 UJ ❑ Rereview (2nd review same parcel)' 7344 $ 24.00 EVALUATION (Attach DOH SAN 53) uy ` ❑ Site Evaluation in Conjunction with ❑ HOLDING TANK 7351 $ 47.00 Critical Area 7348 $111.00 ❑ ALTERNATIVE/EXPERIMENTAL 7345 $222.00 ❑ Site Evaluation Lot Less than SYSTEM 10,000 Sq. Ft. 7347 $ 87.00 1T1411� DATE Holding Tank Agreements Completed 11 Yes o Certification of Existing S.D. System Required ❑ Yes d WQCB Clearance required. (Attach Form ❑ Yes s No DOH SAN 007, Santa Ana Region Only) Soils Percdarion Report Required. ❑ Yes Special Feesiblitty Boring Report Required. ❑ Yes Detailed Contour Plot Plans Required (1 to 5 ft interval) ❑ Yes 6-4 ❑ Yes FNo Staff Specialist Lot Inspection Required ❑ Yes Lot Inspection Date Soils boring report by #t/ Date Soils Map , Page Soil Type Approved by �- --' Doe U Z O No. of Syslame Of Syse) T tem ❑ ceding Tank ❑ Existing No. Dwelling Units J Beds (1) Septi: Tank Soil Rata Gresee/Send � Imp b New ❑ ReplecerrreK !� ggQ441 J 4d-& O ig A W U)Bottrench (2 Leach Line Sq. FL Sidewall allowance If Irtafal Lne(s) R long- wide. leach Bed R ams R rock/ 8 per running R NA min. below dralnlines or bottom area Leachlines/bed special design for slope: Applicable, (3) Ph Diameter / / No. Pits Pit Below Inlet (BI) Seepage PILTotal Depth (TD) I N/A 4000� Overburden factor �Mor &�6 I J Max. Allowabl# Depth I No. 2 System REMARKS: d A 10 p ¢ir This application i PPROV E -D for the category checked in SECTION above, regarding design of a subsurface disposal s ystem as indicated on the accomparned, p t Ian, using the requirements set forth in SECTIO.NiC above. A building permit is necessary for the installation of the above -designed system. No construction is permitted in the;,required reseryetl 100% expansion area. cSeptic"tank"and'sewer'Iines must be 50' minimum from any wellsti 10 _ /LQ�n lXr�o Leach lines must be 100' minimum from any wells, including expansk ar (3 Seepage must be 15Q minimum from �1 pits any wells, including expan on a V /�7 Si nature of Health Officialk/"� [� Date RECEIPT NO. 1;� �y �p Issued By / ""'`�� Date f �� DISTRICT: ❑ Riverside, 9.1Re% ❑ Hemet q Perris ❑ Rancho Calif. ❑ Blythe DOH -SAN -122 (Rev. 7/89) DISTRIBUTION: WHITE - Office file YELLOW - Applicant PINK - Bldg. Dept GOLDENROD - Plans/Records i 0i OFFICE OF AGRICULTURAL COMMISSIONER AND WEIGHTS WMEASURES CALVIN C. KAMINSKAS.. JAMES O. WALLACE 4080 LEMON STREET. ROOM 19 Assistant Commissioner Agk-Whffal CommIsitomer nIVERSIDE, CALIFORNIA 925011. CLEMENT BENVENISTE Oftoclor of Wi§Ights & Meames 17`14) 787-25611 jt 49613 Highway 86, Suite B12 Coachella, Ca- 92236 -8291 (619) 342 DATE CASE NO. 0 DEVEWPERIS NAME: ADDRESS: j 3`j 0 7 TELEPHONE: L Dear Developer: After reviewing your landscaping plans, all plant material listed is not in violation of quarantine -laws governing the Coachella Valley. If substitutions�' do occur and they differ fran plant material listed, this office nust be notified immediately. Thank you for protecting and preserving the Coachella Valley's pest -free envirorm.nt.e.: A&Efcultural Ccinnissioner's office CCII Indo and R vers a ts I t I =��' - _'`���� `� 'tea - I t✓l' b ii ii;1��i �.�,4, 'illi loll rs j: l'i of I I : Buffbin, l;i dub -$afvlt"Wilithiijan This Certificate issued pursuant to the requirements of Section 306 of the Uniform Building:, Code certifying that at the time of issuance this structure was iri compliance with the various. ordinances of the City,regulating building construction or use. For the following: ..44 BUILDING ADDRESS 51-245 Rubio Use Classification SFDr Bldg. Permit No. 7879 Group R3 Type Construction V1QFire Zone Use Zone SR Owner of euildinqPaul Quill Address 54-390 Obregon city La Quinta, CA 92253 ' By; Mark -Harold L � - Date; 2/7/90' ' Building -Official � . r ; POST IN A OONQTICUOU! .►LACt _ 0 RECORDING REQUESTED t3Y Cn ONK)AGO TIITLE WMyAA WVC AND WHEN RECORDED MAIL THIS DEED AND UNLESS OTHERWISE SHOWN BELOW MAIL TAX STATEMENT TO: �amaPaui' D. Quill StreetDor i Z. Q.uill Address54-390 Avenida Obregon ciry&La 'Quinta State Ca. 92253 TO Name Street Address City 8 State 1_/ LJ c O 0 g v oZ 0 v CrH 1 0.0 10 .In Z UQ W 0 v IX �t LL TITLE ORDER NOS 909910-2 1 EscRow No.34 49—JC SPACE ABOVE -THIS LINE FOR RECORDER'S USE GRANT DEED THE UNDERSIGNED GRANTOR(S) DECLARE(S) DOCUMENTARY TRANSFER TAX is $ 56.10 XID computed on full value of property conveyed, or. 0 computed ori full value less value of'liens or encumbrances remaining. at time of sale. 0 unincorporated area )0 city of La Quinta AND FOR A VALUABLE CONSIDERATION, receipt of. which is hereby acknowledged, Mark A. Reis and Danell E. Reis, husband and. wife as joint tenants hereby GRANT(s) to Paul Douglas Quill and Dori Zane Quill, husband and wife as joint terLan.ts the following described real property in the City Of La Quinta .County of Riverside.. State of California: Lots 4 and 5 in Block 48 of SANTA.CARMELITA AT VALE.LA'QUINTA, UNIT N0. 4, as shown by Map on file in Book 18. Page 62 of Maps, Records of Riverside County, California. [APN #773-044-017. & 0181 Dated 'May. 5, 1989 ° �r STATE OF CALIFORNIA COUNTY OF Riverside } SS. Danell E. Reis r On this 10th day of May in theyear.Ts 89 , before me, the undersigned, a Ndtary Public in and for said State, personally appeared Mark A. Reis and Danell E. Reis personally known to me (or proved Jo me on the basis of satisfactory evidence) to be the-=-�= persons whose name S are subscribed to the within OFFICIAL SEAL instrument, and acknowledged to me that hem executed it. �= . CAREN K.- (WAGER 4.,'>: ; r . NOTARY PUBLIC •CALIFORNIA f -PRINCIPAL OFFICE IN WITNESS my hand an fficial seal. ` '�'%?—' ° C� O . RIVERSIDE COUNTY �� Mr Commission Exp. Sept. 8, 1989 Signature NOTARY PUBLIC IN AND FOR SAID STATE (This area for olficial notarial seal( . Caren K. Rager CO -441 (REV 4i85) MAIL TAX STATEMENTS AS DIRECTED ABOVE. ' 1 ® P-Momam".45 e JeA AMA A-- • Vii..mmn ti 79-73:3 Country Club Dr., Suite 5 .r.,,,aa........- y - Bermuda Dunes, CR -92201 (619) .360-8535 CALCULATIONS FOR: Paul Quill 54-390 Obregon La Quinta,/CA Project: Paul Quill Residence 51-245 Rubio La Quinta, CA Standard Design Proposed Design Compliance 59.77 59.36 +0.41 1 original CF -1R C -2R HVAC Sizing MF -1R List of suggested HVAC and water heating equipment selected from CEC certified directories. Actual selection is responsibility -of HVAC and water heating contractor. Micropas Computer Method _ __, i } "Call Ca°"role �� r -Calif. Assoc. Building Energy Consultants .CERTIFICATE OF COMPLIANCO RESIDENTIAL � Page 1 CF -1R ------------------------------------------------------------------------------- Project Title....... . Quill Residence 2550sf Date........ 04/21/90 .Project Address........ 51-245 Rubio --------------------- La Quinta CA ------- --- ----- Documentation Author... C. Randall -Christensen Building Permit # Company... ............. T-24 Energy Calcs Co. ______-__-______- Telephone .............. (619) 360-0535 Plan Check / Date Compliance Method....... MICROPAS3 by Enercomp, Inc. Field Check/ Date Climate Zone........... 15 --------------------- MICROPAS3 v3.01 File-QUILL004 Weather-CTZ15 Program -FORM CF -1R User#-MP1017 User -T=24 Energy Calcs.Co.. Run-R49gEDrp1.1.6HP7.9R19.38.6 ----------------------------------------------------------------------=-------- GENERAL 'INFORMATION ------------------- Conditioned Floor Area..... 2550 sf Building Type ............... Single Family Detached Building Front Orientation. Front Facing 90 deg (E) Number of Dwelling Units... 1 Number of Stories.......... 1 Floor Construction Type.... Slab On Grade Infiltration Control....... Standard BUILDING SHELL INSULATION ------------------------- Component Insul Type R -value Location/Comments --------------------------------------------------------- Wall R-19 Front, Left, Back, Corner, Right to garage Roof R-38 attic, Flat Door R-0 solid wood, to garage S1abEdge R-0 to outside, to garage Glazing Orientation ------------------- Door Front (E) Window Front (E) Window Front (E) Window Left (S) Window Left (S) Window Back (W) Door Back (W) Window Back (W) Window Back (W) Door Back (W) Window Left (SW) Window Back (NW) Window Back (NW) Door Right (N) Window Right (N) Door Right (N) Window Right (N) Window Right (N) Skylight Front (E) GLAZING Area # of Interior Exterior Framing (sf) ------ Panes ----- Shading ---------- Shading -------------- Overhang -------- Type --------- 6 2 drapes 50% bug scrn Yes. Wood 11 2 none None Yes Metal 60 2 drapes 50% bug scrn Yes Metal 29 2 drapes 505 bug scrn Yes Metal 6 2 none None Yes Metal 76 2 drapes 50% bug scrn Yes Metal 33 2 drapes 50% bug scrn Yes WoodMul 18 2 drapes None Yes Metal 24 2 drapes None None Metal 2 2 drapes 50% bug scrn None Wood 6 2 drapes 50% bug scrn Yes Metal 8 12 drapes None Yes Metal 6 2 drapes 50% bug scrn Yes Metal 33 2 drapes 50% bug scrn Yes WoodMul 31 2 drapes 506 bug scrn Yes Metal 2 2 drapes 50% bug scrn Yes Wood 4 2 drapes 50% bug scrn None Metal 3 2 none None Yes Metal 16 2 none None None Metal CERTIFICATE OF COMPLIANCAh RESIDENTIAL Page 2 CF -1R Project Title.......... Quill Residence 2550sf Date........ 04/21/90 ------------- MICROPAS3 v3.01 File-QUILL004 Weather-CTZ15 Program -FORM CF71R User#-MP1017 User -T-24 Energy Calcs Co. Run-R49gEDrp11.6HP7.9R19.38.6 ------------------------------------------------------------------------------- GLAZING Glazing Area # of Interior Exterior Framing Orientation (sf) Panes Shading Shading Overhang Type ----------t--------- ------ ------------ -- -------------- -------- -------- Skylight Back (W) 4 2 none, None None Metal THERMAL MASS Area Thickness Hard Surfaced;/ ' Type (sf) (in) Exposed Location/Comments SlabOnGrade 641 3.5 Yes kit.ent.bath SlabOnGrade 1909 3.5 No typical ASSUMED HVAC SYSTEMS -------------------- Assumed Duct Duct Assumed System Efficiency Location R-value ------- --------------- HeatPump ------------ 7.9 HSPF ------------- Attic R-6.3. Air Conditioner 11.60 SEER Attic R-6.3 ACTUAL HVAC SYSTEMS Actual Output Manufacturer and Model # Actual System Efficiency (Btuh) (or approved equal) --------------- ----------`- -------- --------------------------------- Heating --------- -------- ---- ---------------------------- Cooling Cooling Coil--------------------------------- CEC Maximum Output for Gas Central Furnaces: I Btuh WATER HEATING SYSTEMS --------------------- Tank Capacity Manufacturer and Model # Energy System Type (gal) (or•approved equal) Credits ------------------------------------------------------------------------ Storage, Electric 49 Recovery SPECIAL FEATURES/REMARKS ------------------------ This is a 2 HVAC zone dwelling modeled as 1. Drapes do not have to be installed at time of final inspection by Building Department. 49 gal'elec. water heater with recovery system and equal or better efficiencies as called out in these calculations is the installed maximum unless calcs are run using higher HVAC CERTIFICATE OF COMPLIANCAM RESIDENTIAL Page.3 CF -1R Project Title.......... Quill Residence 2550sf Date........ 04/21/90 MICROPAS3 v3.01 File-QUILL004 Weather-CTZ15 Program -FORM CF -1R User#-MP1017 User -T-24 Energy Calcs Co. Run-R49gEDrp11.6HP7.9R19.38.6 ------------------------------------------------------------------------------- SPECIAL FEATURES/REMARKS ------------------------ efficiencies. Heatpump HSPF 7.9 and SEER 11.6 and Duct R6.3 are minimums. You may install equal or higher efficiency HVAC equipment. The sizing calculations in this document establish the upper limits of sizing based on the orientation for the dwelling unit. ACTUAL DESIGN SIZING OF HEATING AND COOLING EQUIPMENT IS THE RESPONSIBILITY OF THE DESIGN ENGINEER OR MECHANICAL CONTRACTOR. COOLING. The building sensible heat gain calculated in this report meets the criteria of Title 24 and may be used by the mechanical contractor in equipment selection and system design. ----------------------------- #####------------------------------- The shading coefficients for interior shading are for white/ off-white or opaque white shading devices (e.g. drapes/roller shades/venetian or vertical blinds). Light or off-white includes white with a very light pastel tint (e.g. cream colored/eggshell white etc). ,It also includes any mirror-like metallic coating that reflects images. ----------------------------- #####-------------------- =---------- RESPONSIBILITY FOR SIGNING California Energy Commission Energy Conservation Manual Sec. 1-12 ...When"the building type does not require the signature of a licensed individual under the Business and Professions Code the building owner may take responsibility as designer. Energy Calculations for residential buildings do not require the signature of a licensed individual. CERTIFICATE OF COMPLIANCjft RESIDENTIAL Page 4 CF -1R Project Title Quill Residence 2550sf Date........ 04/21/90 ----------------------- MICROPAS3 v3.01 File-QUILL004 Weather-CTZ15 Program -FORM CF -1R User#x-MP1017 User -T-24 Energy Calcs Co. Run-R49gEDrp11.6HP7.9R19.38.6 ------------------------------------------------------------------------------- COMPLIANCE STATEMENT -------------------- This certificate of compliance lists the building features and performance specifications needed to comply with Title 24, Chapter 2-53 and Title 20, Chapter 2, Subchapter 4, Article 1 of the California Administrative code. This certificate has been signed by the individual with overall design responsibility and the building owner, who shall retain a copy of it and transmit the certificate to any subsequent purchaser of the building. When this certificate of compliance.is submitted for a single building plan to be built in multiple orientations, all building conservation features which vary are indicated in the Special Features/Remarks section. DESIGNER Name.... Paul S. Anderson Company. ___ ______________________ Address. P.O. Box 277 La Quinta CA Phone... (619) 564-8060 License. Signed ........... ----------------- (date) DOCUMENTATION AUTHOR Name.... C. Randall -Christensen Company. T-24 Energy Calcs Co. Address. 79-733 Country Club Dr. Bermuda Dunes, CA 92201 Phone... (619) 360-0535 OWNER Name.... Paul Quill Company. -__ ---------------- Address. 54-390 Obregon La Quinta CA Phone... (619) 564-2685 Signed____________________________ (date) ENFORCEMENT AGENCY Name----------------------------- Title... _------------------------ Agency -- _______________________Agency..------------------------- ------------------------- Phone -------------------------------------- Phone... _________________________ Signed Signed --------------------------- (date) (date) a1 -Re COMPUTER METHOD SUMMARY • Page 1 C -2R Project Title.......... Quill Residence 2550sf Date........ 04/21/90 Project Address........ 51-245 Rubio --------------------- La Quinta CA Documentation Author... C. Randall -Christensen Building Permit # Company ................ T-24 Energy Calcs Co. ----------------- Telephone ___________Telephone.............. (619) 360-0535 Plan Check / Date _ ________ ________ Compliance Method...... MICROPAS3 by Enercomp, Inc. Field Check/ Date Climate Zone........... 15 =-------------------- MICROPAS3 v3.01 File-QUILL004 Weather-CTZ15 Program -FORM C -2R User#-MP1017 User -T-24 Energy Calcs Co. Run-R49gEDrp11.6HP7.9R19.38.6 ------------------------------------------------------------------------------- ----------------------------------------------------------------- MICROPAS3 ENERGY USE SUMMARY = ---------------------------- - Energy Use Standard Proposed Compliance = _ (kBtu/sf-yr) _----------------------- Design ---------- Design ---------- Margin = ---------- _ = Space Heating..... ... 7.34 4.86 2.48 - - Space Cooling.......... 45.10 33.34 11.76 = - Water Heating.......... 7.33 21.16 -13.83 = = Total 59.77 59.36 0.41 - _ *** Building complies GENERAL INFORMATION Conditioned Floor Area..... 2550 sf Building Type .............. Single Family Detached Building Front Orientation. Front Facing 90 deg (E) Number of Dwelling Units... 1 Number of Building Stories. 1 Weather Data Type.......... ReducedYear Floor Construction Type.... Slab On Grade Number of Building Zones... 1 Conditioned Volume......... 24225 cf Footprint Area ............. 2550 sf Slab -On -Grade Area......... 2550 sf Glazing Percentage......... 14.8 % of FA Average Ceiling Height..... 9.5 ft BUILDING ZONE INFORMATION Floor Vent Special Cond- Area Volume # of Thermostat Height Vent Area Zone Type itioned (sf) (cf) Units Type (ft) (sf) --------------------------------------- ----------------- ------ --------- HOUSE Residence Yes 2550 24225 1.00 Setback 2.0 n/a COMPUTER METHOD SUMMARY to outside 0.720' R-0 Page 2 C -2R Project Title . Quill Residence 2550sf Date........ 04/21/90 R-0 to MICROPAS3 v3.01 -File-QUILL004 Glass Weather-CTZ15 Program -FORM C -2R -- ------------------------------------------------------------------------------- User#-MP1017 Panes ----- User -T-24 Energy Calcs Co. Run-R49gEDrp11.6HP7.9R19.38.6 Azmth ----- Tilt ---- Only ----- Type ---------- Shade ----- OPAQUE SURFACES 2 Wood Hinged 0.65 Area U- Insul --------------- Act 0.36 Solar Location/ Form 3 Surface ------------ (sf) ------ value ----- R-val ----- Azmth Tilt 0.77 Gains Comments Reference HOUSE 2 Metal Slider ----- ---- 90 ----- ---------------- ------------ 1 Wall 21 0.065 R-19 90 90 No Front 2 Wall 280 0.065 R-19 90 90 Yes Front 3 Wall 405 0.065 R-19 180 90 Yes Left ------------ 4 Wall 453. 0.065 R-19. 270 90 Yes Back 5 Wall 18 0'.065 R-19 225 90 Yes ____ _ _ Corner ___ - -- 6 Wall 34 0.065 R-19 315 90 Yes Corner 7 Wall 220 0.065 R-19 360 90 Yes Right 8 Wall 228 0.065 R-19 90 90 No ------------ to garage _______-___- 9 Roof 992 0.029 R-38 90 18 Yes attic 10 Roof 208 0.029 R-38 180 18 Yes attic 11 Roof 972 0.029 R-38 270 18 Yes ------------ attic 12 Roof 263 0.029 R-38 360 18 Yes attic------�____ 13 Roof 80 0.029 R-38 0 0 Yes Flat ------_^-V- 14 Door 14 0.330 R-0 90 90 No solid wood 15 Door 18 0.330 R-0 270 90 Yes solid wood 16 Door 18 0,.330 R-0 360 90 Yes solid wood 17 Door 20 0.330 R-0 90 90 No - to garage _______±__ Length Surface (ft) HOUSE 18 S1abEdge 38 19 SlabEdge 185 20 S1abEdge 15 21 S1abEdge 46 Surface HOUSE 1 Door 2 Window 3 Window 4 Window 5 Window 6 Window 7 Window 8 Window 9 Window 10 Window 11 Window 12 Door PERIMETER LOSSES ---------------- F2 Insul Factor R-val Location/Comments ------------------------------------- 0.900 R-0 to outside 0.720' R-0 to outside 0.550 R-0 to garage 0.500 R-0 to garage GLAZING SURFACES ---------------- SC Interior SC Area # of Frame Open U- Act Glass Shade GIs+ (sf) ----- Panes ----- Type -------- Type ------ value ----- Azmth ----- Tilt ---- Only ----- Type ---------- Shade ----- 6 2 Wood Hinged 0.65 90 .90 0.67 drapes 0.36 11 2 Metal Fixed 0.65 90 90 0.77 none 0.77 48 2 Metal Slider 0.65 90 90 0.77 drapes 0.48 12 2 Metal Slider 0.65 90 90 0.77 drapes 0.48 3 2 Metal Slider 0.65 180 90 0.77 drapes 0.48 16 2 Metal Slider 0.65 180 90 0.77 drapes 0.48 6 2 Metal Fixed 0.65 180 90' 0.77 none 0.77 2 2 Metal Slider 0.65 180 90 0.77 drapes 0.48 8 2 Metal Slider 0.65 180 90 0.77 drapes 0.48 32 2 Metal Slider 0.65 270 90 0.77 drapes 0.48 44 2 Metal Slider 0.65 270 90 0.77• drapes 0.48 33 2 WoodMul Hinged 0.65 270 �90 0.61 drapes 0.33 COMPUTER METHOD SUMMARY Page 3 C -2R Project Title.......... Quill Residence 2550sf Date......'.. 04/21/90 MICROPAS3 v3.01 File-QUILL004 Weather-CTZ15 Program -FORM C -2R User#=MP1017 User -T-24 Energy Calcs Co. Run-R49gEDrp11.6HP7.9R19.38.6 ----------------- ---------------------------------------------------- ---------- GLAZING SURFACES Sc Interior SC Area # of Frame Open U- Act Glass Shade GIs+ Surface (sf) Panes Type Type value Azmth Tilt Only Type Shade ----------- 13 Window ----- 18 ----- -------- 2 Metal ------ Fixed ----- .0.65 ---'-- 270 ---- 90 ----- 0.77 ---------- drapes ----- 0.48 14 Window 24 2 Metal Fixed 0.65 270 90 0.77 drapes 0.48 15 Door 2 2 Wood Hinged 0.65 270 90 0.67 drapes 0.36 16 Window 6 2 Metal Slider 0.65 225 90 0.77 drapes 0.48 17 Window 8 2 Metal Fixed 0.65 315 90 0.77 drapes 0.48 18 Window 6 2 Metal Slider 0.65 315 90 0.77 drapes 0.48 19 Door 33 2 WoodMul Hinged _0.65 360 90 0.61 drapes 0.33 20 Window 20 2 Metal Slider 0.65 360 90 0.77 drapes 0.48 21 Door 2 2 Wood Hinged 0.65 360 90 0.67 drapes 0.36 22 Window 11 2 Metal Slider 0.65 360 90" 0.77 drapes 0.4.8 23 Window 4 2 Metal Slider 0.65 360 90 0.77 drapes 0.48 24 Window 3 2 Metal Fixed 0.65 360 90 0.77 none 0.77 25 Skylight 16 2 Metal Slider 0.64 90 18 0.77, none 0.77 26 Skylight 4 2 Metal Slider 0.64 270 18 0.77 none 0.77 OVERHANGS Area Window Overhang Overhang 'Surface (sf) Height Length Height ----------- ------ ------ -------- -------- HOUSE 1 Door 6 2.5 10.0 0.5 2 Window 11 5.5 10.0 0.5 3"Window 48 4.0 6.0 0.5 4 Window 12 2.0 6.0 0.5 5 Window 3 .1.0 2.0 2.0 6 Window 16 4.0 2.0 0.5 7 Window 6 2.0 2.0 3.5 8 Window 2 1.0 2.0 2.0 9 Window 8 4.0 2.0 1.0 10 Window 32 4.0 2.0 2.0 11 Window 44 5.6 6.0 1.0 12 Door 33 6.8 6.0 1.0 13 Window 18 3.0 6.0 1.0 16 Window 6 4.0 6.0 1.0 17 Window 8 4.0 6.0 1.0 18 Window 6 4.0 12.0 1.0 19 Door 33 6.8 2.0 0.0 20 Window 20 5.0 2.0 0.0 21 Door 2 1.5 4.0 3.0 22 Window 11 3.6 2.0 3.5 24 Window 3 1.0 2.0 1.0 COMPUTER METHOD SUMMARY Page 4 C -2R __-___-_--------- Project -Title Quill Residence 2550sf Date........ -04/21/9'0 --------------------------- MICROPAS3 v3.01 File-QUILL004 Weather-CTZ15 Program -FORM C -2R User##-MP1017 User -T-24 Energy Calcs Co. Run-R49gEDrp11.6HP7.9R19.38.6 ------------------------------------------------------------------------------- Mass Type, --------------- HOUSE 1 S1abOnGrade 2 S1abOnGrade EXTERIOR SHADING MVAC SYSTEMS Area Shading -Duct SC of Surface (sf ) Type, R -value Efficiency Ext Shade ------------ HOUSE ------ --------------- HeatPump --------- 1 Door 6 50% bug scrn 0.84 3 Window 48 50% bu scrn 0.84 4 Window 12 50% bu scrn 0.84 5 Window 3 50% bug scrn 0.84 6 Window 16 50% bug scrn 0.84 8 Window 2 506 bug scrn 0.84 9 Window 8 50% bug scrn 0.84 10 Window 32 '50% bug scrn 0.84 11 Window 44 50% bug scrn 0.84 12 Door 33 50% bug scrn 0.84 15 Door 2 506 bug scrn 0.84 16 Window 6 50% bug scrn 0.84 18 Window 6 50% bug scrn 0.84 19 Door 33 50% bug scrn 0.84 20 Window 20 50% bug scrn 0.84 21 Door 2 50% bug scrn 0.84 22 Window 11 50% bug scrn 0.84 23 Window 4 505 bug scrn 0.84 THERMAL MASS Area Thick ------------ Heat Conduct- Surface (sf) (in) ------ ----- Cap ----- ivi.ty -------- R -value -------- Location/Comments -------------------------- 641 3.5 28.0 0.98 R-0.0 kit.ent.bath 1909 3.5 28.0 0.98 R-2.0 typical MVAC SYSTEMS WATER HEATING SYSTEMS Capa- Pilot System ## of city Effic- Standby Input Size Type Heaters (gal) iency Loss Rating (Btuh) Credits ---------- -------------------------- ------ ------------ -------- ---------- Storage Electric 1 49 0.990 RE 6.00% 4 kW n/a RECOVERY Minimum Duct -Duct Duct System Type Efficiency Location R -value Efficiency HOUSE HeatPump 7.9 HSPF Attic R-6.3 0.840 Air Conditioner 11.60 SEER Attic R-6.3 0.830 WATER HEATING SYSTEMS Capa- Pilot System ## of city Effic- Standby Input Size Type Heaters (gal) iency Loss Rating (Btuh) Credits ---------- -------------------------- ------ ------------ -------- ---------- Storage Electric 1 49 0.990 RE 6.00% 4 kW n/a RECOVERY COMPUTERMETHODSUMMARY Page 5 C -2R Project Title.......... Quill Residence 2550sf Date........ 04/21/90 MICROPAS3 v3.01 File-QUILL004 Weather-CTZ15 Program -FORM C -2R User#-MP1017 User -T-24 Energy Calcs Co. Run-R49gEDrp11.6HP7.9R19.38,.6 -------------------------------------------------------------------------------- SPECIAL FEATURES/REMARKS ------------------------ This is a 2 HVAC zone dwelling modeled as 1. Drapes do not have to be installed at time of final inspection by Building Department. 49 gal elec. water heater with recovery system and equal or better efficiencies as called out in these calculations is the installed maximum unless calcs are run using higher HVAC efficiencies. Heatpump HSPF 1.9 and SEER 11.6 and Duct R6.3 are minimums. You may install equal or higher efficiency HVAC equipment. The sizing calculations in this document establish the upper limits of sizing based on the orientation for the dwelling unit. ACTUAL DESIGN SIZING OF HEATING AND COOLING EQUIPMENT IS THE RESPONSIBILITY OF THE DESIGN ENGINEER OR MECHANICAL CONTRACTOR. COOLING. The building sensible heat gain calculated in this report meets the criteria of Title 24 and may be used by the mechanical contractor in equipment selection and sysitem design. ----------------------------- #####------------------------------- The shading coefficients for interior shading are for white/ off-white or opaque white shading devices (e.g. drapes/roller shades/venetian or vertical blinds). Light or off-white includes white with a very light pastel tint (e.g. cream colored/eggshell white etc). It also includes any mirror-like metallic coating that reflects images. ----------------------------- #####------------------------------- RESPONSIBILITY FOR SIGNING California Energy Commission Energy Conservation Manual. Sec. 1-12 ...When the building type does not require the signature of a licensed individual under the Business and Professions Code the building owner may take responsibility as designer. Energy Calculations for residential buildings do not require the signature of a licensed individual. WATER HEATING Page 1 DHW Project Title .. ....... Quill Residence 2550sf -----Date --------_04/21/90 Project Address.'....... 51-245 Rubio --------------------- La Qu i nta CA_ __.___ _ Documentation Author.... C. Randall -Christensen Building Permit-# Company ................ T-24 Energy Calcs Co. Telephone............... (619) 3-60-0535 Plan Check / Date ----------------- Compliance Method...... MICROPAS3•by Enercomp, Inc. Field Check/ Date Climate Zone........... 15 --------------------- MICROPAS3 v3.01 File-QUILL004 Weather-CTZ15 Program -WATER HEATING User#-MP1017 User -T-24 Energy Calcs Co.' Run-R49gEDrp11.6HP7.9R19:38.6 -------------------------------------------------------------------------------- GENERAL INFORMATION ------------------- Conditioned Floor Area..... 2550 sf Building Type...... Single Number of Dwelling Units... 1 WATER HEATER INPUTS System Type ................ DHW Number of Heaters.,......... 1 Tank Type.........:........ Storage Heater Element Type........ Electric Tank,Volume................ 49 gal Rated Input ................ 4 kW Recovery Efficiency........ 0.99 RE Standby Loss ............... 0.06 Credit Type ................ Recovery Pump Power .................. 0 W. Pump Operation .............. 24 hr/day Pump Controller Power...... 0 W CALCULATION DETAILS COMBINED HYDRONIC DISTRIBUTION Heat supplied by fan ...... 0 Btuh Fan coil loss: fan off .... 0 Btuh Fan coil loss: fan on ..... 0 Btuh Pipe heat loss ............ 0 kBtu/sf-yr Space Heat Operation ....... 0 hr/yr LOADS Annual savings with Credit. 2805 kBtu/yr DHW recovery load '10539 kBtu/yr Space heat load ........... 0 kBtu/yr Pipe loss load ............. 0 kBtu/yr Fan Coil Loss 0 kBtu/yr Total load ................ 7734 kBtu/yr SOURCE ENERGY WATER HEATING • • Page 2 DHW Project.Title.......... Quill Residence 2550sf Date.. ....04/21/90 MICROPAS3 v3.01 File-QUILL004 Weather-CTZ15 Program -WATER HEATING User#-MP1017 User -T-24 Energy Calcs ------------------------------------------------------------------------------- Co. Run-R49gEDrp11.6HP7.9R19.38.6 Total recovery energy...... 23438 kBtu/yr Pilot light energy ........ 0 kBtu/yr Standby loss energy ....... 30518 kBtu/yr DHW Pump energy ........... 0 kBtu/yr Solar Pump Energy .......... 0 kBtu/yr Space Heat Fan and Pump ... 0 kBtu/yr Boiler exhaust Fan ........ 0 kBtu/yr Boiler to Storage Pump 0 kBtu/yr Total Fan/Pump ............ 0 kBtu/yr T.otal.Source Energy ....... 53956 kBtu/yr ELECTRIC USE ------------ Recovery Energy........ ... 2289 kWh Standby Loss Energy........ 2981 kWh' Pump and Fan Energy........ 0 kWh Total Electric Use......... FUEL USE Recovery.Energy............ Pilot Light Energy...... . Standby Loss Energy........ Total Fuel Use........... 5270 kWh 0 k8tu 0 k8tu 0 k8tu 0 k8tu TOTAL SOURCE USE ---------------- Total Electric Use......... 21.16 kBtu/sf Total Fuel Use ............. 0.00 kBtu/sf Total Use .................. 21.16 kBtu/sf HVAC SIZING Page 1 HVAC Project Title.......... Quill Residence 2550sf Date. 04/21/90 Project Address........ 51-245 Rubio --------------------- La Quinta CA Documentation Author... C. Randall -Christensen Building Permit # Company........... ... T-24 Energy Calcs Co.Telephone .............. .............. (619) 360-0535 Plan -Check / Date -------- ------ Compliance Method...... MICROPAS3 by Enercomp, Inc. ( Field Check/ Date Climate Zone........... 15 --------------------- MICROPAS3 v3.01 File-QUILL004 Weather-CTZ15 Program -HVAC SIZING User#-MP1017 User -T=24 Energy Calc.s Co. Run-R49gEDrp11.6HP7.9R19.38.6 ------------------------------------------------------------------------------- GENERAL INFORMATION ------------------- Floor Area ................. 2550 sf Volume ..................... 8358 24225 cf. Sizing Location............ INDIO Latitude ................... 33.7 degrees Winter Outside Design:..... 29 F Winter Inside Design....... 70 F Summer Outside Design...... 112 F Summer Inside Design....... 78 F Summer Range ............... 30.F Shading Used ............... Yes Latent Load Fraction....... 0.20 HEATING AND COOLING LOAD SUMMARY -------------------------------- Description --------------------------------- Opaque Conduction and Solar...... Glazing Conduction ............... Glazing Solar.... .............. Infiltration ..................... Internal Gain... ................. Ducts............................ Sensible Load .................... Heating Cooling (Btuh) (Btuh) ---------------------- 16503 7898 10079 8358 n/a-, 10162 14285 8465 n/a 2550 4087 3743 44953 41177 Latent Load ...................... n/a 8235 Total Load 44953 49412 Note: The loads shown are only one of the criteria affecting the selection of HVAC equipment. Other relevant design factors such as air flow requirements, outdoor design temperatures, coil sizing, availability of equipment, oversizing safety margin, etc., must also be considered. It is the HVAC designer's responsibility to consider all factors when selecting the HVAC equipment. CEC Maximum applicable for gas central furnaces only HVAC SIZING • Page 2 HVAC Project Title .......... *Quill Residence 2550sf Date........ 04/21/90 MICROPAS3 v3.01 File-QUILL004 Weather-CTZ15 Program -HVAC SIZING User##-MP1017 User -T-24 Energy Calcs Co. Run-R49gEDrp11.6HP7.9R19.38.6 ------------------------------------------------------------------------------- HEATING LOAD CALCULATIONS ------------------------- DESIGN CONDITIONS FOR ZONE 'HOUSE': WINTER DESIGN TEMPERATURES: Inside Temperature ................................ 70.0 F Outside Temperature ............................... 29.0 F DESIGN TEMPERATURE DIFFERENCES East 6 x 0.65 x 41.0 - Standard .......................................... Double Window East 41.0 x F x CONDUCTIVE HEAT LOSS: 293 Double Window U -value 48 x Heat x 41.0 = Area Double (Btu/hr- East TD Loss Description -------------------------- Orientation ----------- (sgft) ------ 320 sgft-F) ------- (F) (Btuh) Shaded Wall n/a 21 x 0.065 ------- x 41.0 -------- - 56 Wall East 280 x 0.065 x 41.0 = 746 Wall South 405 x 0.065 x 41.0 = 1079 Wall West 453 x 0.065 x 41.0 - 1207 Wall Southwest 18 x 0.065 x 41.0 - 48 Wall Northwest 34 x 0.065 x 41.0 - 91 Wall North 220 x 0.065 x 41.0 = 586 Shaded Wall n/a 228 x 0.065 x 41.0 = 608 Roof East 992 x 0.029 x 41.0 - 1179 Roof South 208 x 0.029 x 41.0 - 247 Roof West 972 x 0.029 x 41.0 = 1156 Roof North 263 x 0.029 x 41.0 - 313 Roof Horizontal 80 x 0.029 x 41.0 = 95 Shaded Wall n/a 14 x 0.330 x 41.0 - 189 Door West 18 x 0.330 x 41.0 - 244 Door North 18 x 0.330 x 41.0 = 244 Shaded Wall n/a 20 x 0.330 x 41.0 = 271 SlabEdge n/a 38 x 0.900 x 41.0 - 1402 SlabEdge n/a 185 x 0.720 x 41.0 = 5461 SlabEdge n/a 15 x 0.550 x 41.0 = 338 SlabEdge n/a 46 x 0.500 x 41.0 - 943 CONDUCTIVE TOTALS FOR OPAQUE SURFACES 16503 Double Door East 6 x 0.65 x 41.0 - 160 Double Window East 11 x 0.65 x 41.0 - 293 Double Window East 48 x 0.65 x 41.0 = 1279 Double Window East 12 x 0.65 x '41.0 - 320 Double'Window South 3 x 0.65 x 41.0 = 80 Double Window South 16 x 0-65 x 41.0 = 426 Double Window South 6 x 0.65 x 41.0 - 160 Double Window South 2 x 0.65 x 41.0 = 53 Double Window South 8 x 0.65 x 41.0 = 213 Double Window West 32 x 0.65 x 41.0 - 853 Double Window West 44 x 0.65 x 41.0 - 1173 Double Door West 33 x 0.65 x 41.0 = 879 Double Window West 18 x 0.65 x 41.0 = 480 CONDUCTIVE TOTALS FOR GLAZING SURFACES 10079 INFILTRATION: (Type: Medium) 24225 cuft x 0.80 ac/hr x 0.018 Btu/cuft-F x 41.0 - 14285 SUBTOTAL 40867 DUCT HEAT LOSS: Duct Location: Attic 0.10 x 40867 = 4087 TOTAL HEATING LOAD: 44953 COOLING LOAD CALCULATIONS ------------------------- DESIGN CONDITIONS FOR ZONE 'HOUSE': SUMMER DESIGN CONDITIONS: Inside Temperature ................................ 78.0 F Outside Temperature...............................112.0 F Temperature Range ................................. 30.0 F DESIGN EQUIVALENT TEMPERATURE -DIFFERENCES Standard.......................................... 34.O F Frame Walls and Doors........ ................... 32.6 F Ceiling Under Vented Attic ........................ 53.0 F Frame Partitions .................................. 24.0 F SHADING CALCULATIONS: . Over- Over- .'HVAC SIZING Un - Page 3 HVAC Project Title.......... Shade ----------------------------=====04/21/90 Quill Residence 2550sf Glaz Shaded Date MICROPAS3 v3.01 File-QUILL004 Weather-CTZ15 Leng. High. Program -HVAC SIZING High. User##-MP1017 User -T-24 Energy Calcs..Co. Run=R49gEDrp11.6HP7.9R19.38.6 Description --------------- 0. -- ---=--- Fact. Double Window West 24 x 0.65 x --------------- 41.0 = 640 Double Door West 2 x 0.65 x 41.0 - 60 Double Window Southwest 6 x 0.65 x 41.0 - 160 Double Window Northwest 8 x 0.65 x 41.0 - 213 Double Window Northwest 6 x 0.65 x 41.0 - 160 Double Door North 33 x 0.65 x 41.0 = 879 Double Window North 20 x 0.65 x 41.0 - 533 Double Door North 2 x 0.65 x 41.0 - 60 Double Window North 11 x 0.65 x 41.0 - 293 Double Window North 4 x 0.65 x 41.0 = 107 Double Window North 3 x 0.65 x 41.0 - 80 Double Skylight Horizontal 16 x 0.64 x 41.0 - 420 Double Skylight Horizontal 4 x 0.64 x 41.0 - 105 CONDUCTIVE TOTALS FOR GLAZING SURFACES 10079 INFILTRATION: (Type: Medium) 24225 cuft x 0.80 ac/hr x 0.018 Btu/cuft-F x 41.0 - 14285 SUBTOTAL 40867 DUCT HEAT LOSS: Duct Location: Attic 0.10 x 40867 = 4087 TOTAL HEATING LOAD: 44953 COOLING LOAD CALCULATIONS ------------------------- DESIGN CONDITIONS FOR ZONE 'HOUSE': SUMMER DESIGN CONDITIONS: Inside Temperature ................................ 78.0 F Outside Temperature...............................112.0 F Temperature Range ................................. 30.0 F DESIGN EQUIVALENT TEMPERATURE -DIFFERENCES Standard.......................................... 34.O F Frame Walls and Doors........ ................... 32.6 F Ceiling Under Vented Attic ........................ 53.0 F Frame Partitions .................................. 24.0 F SHADING CALCULATIONS: Over- Over- Un - Shade hang hang Shade Glaz Glaz Shaded shaded Line Leng. High. High. High. Area Area Area Description --------------- 0. -- ---=--- Fact. (ft) ----- (ft) ----- (ft) ----- (ft) ----- (sf) ----- (sf) ------ (sf) ------ Double, Door E ( 0.8 x 10.0) - 0.5 = 7.5 / 2.5 x 6 = 18 0 Double Window E ( 0.8 x 10.0) - 0.5 = 7.5 / 5.5 x 11 = 15 0 Double Window E ( 0.8 x 6.0) - 0.5 = 4.3 / 4.0 x 48 = 52 0 Double Window E (.0.8 x 6.0) - 0.5 = 4.3 / 2.0 x 12 = 26 0 Double Window S ( 4.1 x 2.0) - 2.0 = 6.1 / 1.0 x 3 = 18 0. CONDUCTIVE TOTALS FOR OPAQUE SURFACES 7898 Double Door East 6 x 0.65 x 34.0 = 133 Double HVAC- SIZING East 11 x 0.65 x 34.0 = Page 4 HVAC Project Title.......... Quill Residence 2550sf x Date........ 04/21/90 ------------------------------------------------------------------------------- MICROPAS3 v3.01 File-QUILL004 Weather-CTZ15 Program -HVAC SIZING User#-MP1017 User -T-24 Energy Calcs Co. Run-R49gEDrp11.6HP7.9R19.38.6 34.0 = 265 ------------------------------------------------------------------------------- Double Window S ( 4.1 x 2.0) - 0.5 = 7.6 / 4.0 x 16 = 31 0 Double Window S ( 4.1 x 2.0) - 3.5 = 4.6 / 2.0 x 6 = 14 0 Double Window S ( 4.1 x 2.0) - 2.0 = 6.1 / 1.0 x 2 = 12 0 Double Window S ( 4.1 x 2.0) - 1.0 = 7.1 / 4.0 x 8 = 14 0 Double Window W ( 0.8 x 2.0) - 2.0 = 0.0 / 4.0 x 32 = 0 32 Double Window W ( 0.8 x 6.0) - 1.0 = 3.8 / 5.6 x 44 = 30 14 Double Door W ( 0.8 x 6.0) - 1.0 = 3.8 / 6.8 x 33 = 18 15 Double Window W ( 0.8 x 6.0) - 1.0 = 3.8 / 3.0 x 18 = 23 0 Double Window SW ( 1.5 x 6.0) - 1.0 = 7.7 / 4.0 x 6 = 12 0 CONDUCTIVE HEAT GAIN: West 2 x U -value x 34.0 - Heat Double Window Southwest 6 x Area (Btu/hr- 34.0 - TDeq Gain Description -------------------------- Northwest 8 x Orientation ----------- (sgft) ------ sgft-F) ------- ------- (F) (Btuh) Shaded Wall 6 x 0.65 n/a 21 x 0.065 x 24.0 - -------- 33 Wall x 0.65 x East 280 x 0.065 x 32.6 - 593 Wall South 405 x 0.065 x 32.6 = 858 Wall West 453 x 0.065 x 32.6 = 960 Wall Southwest 18 x 0.065 x 32.6 - 38 Wall Northwest 34 x 0.065 x 32.6 - 72 Wall North 220 x 0.065 x 32.6 - 466 Shaded Wall n/a 228 x 0.065 x 24.0 = 356 Roof East 992 x 0.029 x 53.0 - 1525 Roof South 208. x 0.029 x 53.0 - 320 Roof West 972 x 0.029 x 53.0 - 1494 Roof North 263 x 0.029 x 53.0 = 404 Roof Horizontal 80 x 0.029 x 53.0 - 123 Shaded Wall n/a 14 x 0.330 x 24.0 = 111 Door West 18 x 0.330 x 32.6 - 194 Door North 18 x 0.330 x 32.6 = 194 Shaded Wall n/a 20 x 0.330 x 24.0 = 158 CONDUCTIVE TOTALS FOR OPAQUE SURFACES 7898 Double Door East 6 x 0.65 x 34.0 = 133 Double Window East 11 x 0.65 x 34.0 = 243 Double Window East 48 x 0.65 x 34.0 = 1061 Double Window East 12 x 0.65 x 34.0 = 265 Double Window South 3 x 0.65 x 34.0 - 66 Double Window South 16 x 0.65 x 34.0 = 354 Double Window South 6 x 0.65 x .34.0 - 133 Double Window South 2 x 0.65 x 34.0 = 44 Double Window South 8 x 0.65 x 34.0 = 177 Double Window West 32 x 0.65 x 34.0 - 707 Double Window West 44 x 0.65 x 34.0 - 972 Double Door West 33 x 0.65 x 34.0 - 729 Double Window West 18 x 0.65 x 34.0 _' 398 Double Window West 24 x 0.65 x 34.0 - 530 Double Door West 2 x 0.65 x 34.0 - 50 Double Window Southwest 6 x 0.65 x 34.0 - 133 Double Window Northwest 8 x 0.65 x 34.0 = 177 Double Window Northwest 6 x 0.65 x 34.0 = 133 Double Door North - 33 x 0.65 x 34.0 - 729 CONDUCTIVE TOTAL FOR GLAZING SURFACES 8358 SOLAR HEAT • HVAC SIZING Heat Page 5 HVAC Pr.oject Title.......... Quill Residence,2550sf Shading ----------------------- Date Orientation .. 04/21/90 MICROPAS3 v3.01 File-QUILL004 Weather-CTZ15 Program -HVAC --------------------------- Double SIZING User#-MP1017 User -T-24 Energy Calcs ------------------------------------------------------------------------------- Co. Run-R49gEDrp11.6HP7.9R19.38.6 x ---- 15 x ------- 0.64 = Double Window North 20 x 0.65 x 34.0 - 442 Double Door North 2 x '0.65 x 34.0 - 50 Double Window North 11 x 0.65 x 34.0 = 243 Double Window North 4 x 0.65 x 34.0 = 88 Double Window North 3 x 0.65 x 34.0 - 66 Double Skylight Horizontal 16 x 0.64 x 34.0 = .348 Double Skylight Horizontal 4 x 0.64 x 34.0 - 87 CONDUCTIVE TOTAL FOR GLAZING SURFACES 8358 SOLAR HEAT GAIN: Heat Area Shading Gain Description Orientation (sqft) SHGF Coeff. (Btuh) --------------------------- Double Door ------------- Shaded -------- 6 x ---- 15 x ------- 0.64 = -------- 57 Double Window Shaded 11 x 15 x 0.77 - 127 Double Window Shaded 48 x 15 x 0.74 = 532 Double Window Shaded 12 x 15 x 0.74 = 133 Double Window Shaded 3 x 15 x 0.74 - 33 Double Window Shaded 16 x 15 x 0.74 = 177 Double Window Shaded 6 x 15 x 0.77 = '69 Double Window Shaded 2 x 15 x 0.74 = 22 Double Window Shaded 8 x 15 x 0.74 - 89 Double Window West 32 x 73 x 0.74 - 1727 Double Window West 14 x 73 x 0.74 - 763 Double Window Shaded 30 x 15 x 0.74 - 331 Double Door West 15 x 73 x 0.59 - 625 Double Door Shaded 18 x 15 x 0.59 - 163 Double Window Shaded 18 x 15 x 0.77 = 208 Double Window West 24 x 73 x 0.77 = 1349 Double Door West 2 x 73 x 0.64 = 105 Double Window Shaded 6 x 15 x 0.74 = 67 Double Window Northwest 8 x 48 x 0.77 = 296 Double Window Northwest 6 x 48 x 0.74 = 213 Double Door North 33 x 15 x 0.59 = 291 Double Window North 20 x 15 x 0.74 = 222 Double Door North 2 x 15 x 0.64 = 22 Double Window North. 11 x 15 x 0.74 = 122 Double Window North 4 x 15 x 0.74 = 44 Double Window North 3 x 15 x 0.77 - 35 Double Skylight Horizontal 16 x 152 x 0.77 - 1873 Double Skylight Horizontal 4 x 152 x 0.77 - 468 SOLAR TOTAL 101.62 INFILTRATION: (Type: Medium) 24225 cuft x 0.57 ac/hr x 0.018 Btu/cuft-F x 34.0 = 8465 INTERNAL GAIN: 6 People x 225 Btu/person + 1200 Btu (appliance) = 2550 'HVAC SIZING Page 6 HVAC Project Title.......... Quill Residence 2550sf Date... .... 04/21/90 ----------------- MICROPAS3 v3.01 File-QUILL004 Weather-CTZ15 Program-HVAC SIZING User#-MP1017 User-T-24.Energy Calcs Co. Run-R49gEDrp11.6HP7.9R19.38.6 ----=-------------------------------------------------------------------------- SUBTOTAL 37434 DUCT HEAT GAIN: Duct Location: Attic 0.10' x 37434 3743 TOTAL HOURLY SENSIBLE HEAT GAIN 41177 LATENT LOAD: 0.20 x 41177 - 8235 TOTAL COOLING LOAD 49412 MANDATORY MRAaURRa.CHRCRLIST: RUIDRNTIAL MF-1R -------------------------------------------------------=------ NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. Items marked with an asterisk($) may be superseded by more stringent compliance requirements listed on the Certificate of Compliance. When this checklist is inc'orporated into the permit documents, the - features noted shall be considered by all parties as binding minimum component performance specifications for the mandatory measures whether they are' shoran elsewhere in the documents or on this checklist only. DESCRIPTION ;Designer ;Enforcement; Building Envelope Measures t9ec.2-5352(a): Minimum ceiling insulation R-19 weighted average, Sec,2-5352(b): Loose fill insulation manufacturer's labeled R -Value. #Sec.2-5352(c): Minimum wall insulation in framed walls R-11 weighted average (does not apply to exterior mass walls). Sec.2-5352(k): Slab edge insulation - water absorption rate no greater than 6.3%, water vapor transmission rate no greater than 2,0 perm/inch, Sec.2-5311: Insulation specified or installed meets California Energy Commission (CEC) quality standards. Indicate type and form. ' Sec.2-5352(f): Vapor barriers mandatory in Climate Zones 14 and 16 only. Sec.2-5317: Infiltration/Exfiltration Controls ' a. Doors and windows between conditioned and uncondition spaces designed'to limit ' air leakage. b. Doors and windows certified. c. Doors and windows weathergtripped; all joints and penetrations caulked and sealed. ' Sec.2-5352(e): Special infiltration barrier installed to comply with Sec.2-5351 meets ' CEC quality standards, Sec.2-5352(d): Installation of Fireplaces 1. Masonry and factory -built fireplaces have: a. Tight fitting, closeable metal or glass door. b, Outside air intake with damper and control , ' c. Flue damper and control 2. No continuous burning gas pilots allowed. HVAC and Plumbing S stem Measures Sec.2-5352(g) and 2-5303: Space conditioning equipment sizing: attach calculations.' Sec.2-5352(h) and 2-5315: Setback thermostat on all applicable heating systems. SSec.2-5316(a): Ducts construcied,.installed and insulated per Chapter 1®, 1976 UMC. Sec.2-5316(b): Exhaust systems have damper controls. ' Sec.2-5314(c): Gas-fired space heating equipment has intermittent ignition devices. Sec.2-5314: HVAC equipment, water heaters, showerheads and faucets certified by the CEC, ' 5ec.2-5352(i): Water heater insulation blanket (R-12 or greater) or combined interior/exterior insulation (R-16 or greater); first 5 feet of pipes closest to tank insulated (R-3 or greater) ; Sec.2-5312(Exception I); Pipe insulation on steam and steam condensate return & recirc piping. Sec.2-5318(d): Swimming Pool Heating System has: 1 a. On/off switch on heater. b, Weatherproof instruction plate on heater. , ; c. Plumbed to allow for solar. ; 2. 75 percent thermal efficiency. 3. Pool cover. ' , 4. Time clock. 5, Directional water inlet. Lighting and Appliance Measures Sec.25352(j): Lighting -25 lumens/watt or greater for general lighting in kitchens and bathrooms Sec.2-5314(c): Gas fired appliances equipped with intermittent ignition devices. Sec.2-5314(a): Refrigerators, refrigerator -freezers, freezers and fluorescent lamp ballasts certified by the CEC. Indicate make and model number. ' Form Revised December 1987 n SUGGESTED EQUIPMENT . . F��ge Nb. DIRECTORY OF CERTIFIED STORAGE WATER ' HEATERS ` Updated 3/1/90 ' Electric (WES) .[ ' T-24 Energo Calcs Co. ' ^ 79-733 Country Club Dr.4 Bermuda Dunes, PA 92201 ' HVAC Contractor is responsible for selection of .^equipment. This list pf suggested equipment 's �provided as A'courtesy only. 'Equipment' Finder v1.1 ' User # EF0160 ________________-______________------- _------ ___ ' ' Selection Criteria!, Brand..,............ 58 of 58 selected ` Volume.............. from 45.0 up to 49,0 . Recovery Efficiency. from 99�.0 up to 99.5 Rated Input.......,. from 3.0 up to 4,0 ' 04/23/90 , ^ R e c Stand Rated ` Brand Vol Eff by Input Hght Wdth R16 Model Nulber (gal) (%) (%/hr> (kw) (in) (in) ? _____________________________ _______ ____ ______ ______ ____ ____ ___ SEARS ECONOMIZER 5 153.313560 SEARS ECONOMIZER 5 153.315560 � SEARS POWER MISER 153.310560 SEARS POWER MISER 153.315520** SEARS POWER MISER 153.316560 SEARS POWER MISER 1531318560 SEARS POWER MISER 153.319520** SEARS POWER MISER 153.324520** ^ 47.6 99.0 0.75 ` 4 0 0 Y` ' 47.6 99.0 0.75 ` 4 0 0 Y 47.6 99.0 0.65 4 0 0 Y 47.0 99.0' 0.75 4` 0 0 N ' 47.6 99.0 0.75 4 0 0 Y 47.6 99.0 0.65 . 4 . 0 0 Y 47.0 99.0 . 0.75 . 4 . 0 0 N 47.0 99.0 ` 0.92 4 0 0 N / Page No. DIRECTORY OF CERTIFIED CENTRAL.. E- EAT RUM!" S Updated 3/1/90 Split Sy=stem Air Source (4-1P2) T-24 Energ .C-a:i cs Co. 79-733 Country Club Dr., Bermuda Dunr•.:•s, CA 92201 ' HVAC Contractor is re<spon_,ike for selection of e-,gai.porient.. This list of 'sugge:rpted equipment is provided as a courtesy only. Equipment Finder v1.1 7 User # EF0160 Selection'Cr.i.ter:ia: -------- SEER. u.e...n=o.<<... from 11..60 up to 13.00 ' HSPF .. a .... a .. s .. o . 1 from 7.9 - t. p to 8.5 Heating Cap to 47F • .. from .19000 up to 4200i ' { ACOP ..a.o ........... from•' e5 up to 14.0 04/23/90 Brand Cooling Heating Compressor Model Capacity Capacity Non -Compressor Model (Btuh) EER SEER HSPF ----- @'47F ACOP Type COLEMAN' ' ' ^ _?1400 10.6 1.2 . 69 . Cad 1. 24400 Y 3.3 38 ' 3724-911 , 69 2--I)UVO COLEMAN - .28200 11.4 12,00 8.3 x:90007 3.61 ,18 340-911 3736-833 L_ENNOX -36000 9,3 12.00 8.0 35400 3.1 40 I- P 14-- `61 / 411. V--.1 3P CB19--41.-.1 F' - L_ENNOX 36000 9.3 1.^a00 B.0 q 35400 3.1 40 I...IF;14••-261/1411.V-1141 , L=EI\INOX C019 -31-1P F77-170-73 ft800.1107 12.=5.., 7.9 1000• 315 140 Ed ' C; B 19 -- 21. --1. E::' L..EI'•;NOX i '� 0►� 11.2 12.80,8.5 _'61400 3 5; , 40 I•-IP22 -411- 1.f"' CB19-41. -1: F' 4 ' LE:NNOX 42000 11.3 121801 8.5- 42000 315 401. Hf-'^' -461•-1C- , CB1.9--51--.1 E- f ; RHEEhI 24SOO 10A .1 1•.1 .10 7.9 2380P 3.1' '40 . E;POB--tL240A u _ RHQA•--08* (F C;C1B--IjCn2,n. *) RI-1EE::NI ' : ' 00200, 1 0.8 12.20e- Sa 4 29`400• 313 40 `. ARi=GP-•-0`30JA*.. •• - RHUA.:._ 1 _; fix is RCC!040 6*) , Fit!t.1I? , 24CSCl O 10.1:11.60 7. y '� SOO' 1.1' 40 DIRECTORY C.}!'- CERTIFIED CEN-1".RA!.... }-1EAT h'1Jh1PS Updated 3/1/90' 0 SplitSystem Air Source (Hf=2) T-24 Energy Calps Co. 79_.7Country C1uh Dr,„ Bermuda, Dunes, CA ?2101. HVAC C'`ont.r--nr=tor is rEspc r7__ble_ fe,rscloc"t:ini'r of equiplenV This list of suggested equipment is provided as a courtesy only. Equipment Finder v1 01 ' User- # E:F0160 Selection Criteria,., Brandy 4 .. > > .. n 36 of 3E selected SEER ..oa.o.....,a, , from 1.1.60 yip to 13o00 , Heating Crap @ 47F.. o from,19000 up tV 42000 ACOP. a o d . a , .. U a from 2a::5 up to 7.,0 04/23/90 Brand Cooling Heating Compressor Model Capacity Capacity Non--Compressor Model (Btuh) EER CLEC; HCF'F @ 47F WOP Type UPGD-•-0243A t II. OA-•-0W (Rf'.Oi;._.Ii02.c * ) RUi_1D 30200 10.S 12.20 S.4 4?9400 " 3.3 40 UPC.;B...-0303 A * TRANE 32800 0 1.0L7 12.3 5 7.9 2� J4C0 3.4 40 TWX7 0D TWV739P! 5 -C MANDATORY MEASURES CHECKLIST: RESIDENTIAL MF -1R ---------------------------------------------------------------------------------------------------------------------- ---------------------------------------------------------------------------------------------------------------------- NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. Items marked with an asterisk(*) may be superseded by more stringent compliance requirements listed on the Certificate of Compliance. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as binding minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. DESCRIPTION ;Designer ;Enforcement; Building Envelope Measures ' $Sec.2-5352(a): Minimum ceiling insulation R-19 weighted average. ' f t Sec,2-5352(b): Loose fill insulation manufacturer's labeled R -Value, iSec,2-5352(c); Minimum wall insulation in framed walls R-11 weighted average (does not apply to exterior mass walls). ; Sec,2-5352(k): Slab edge insulation - water absorption rate no greater than 0.3%, water vapor transmission rate no greater than 2,0 perm/inch, ' t t Sec.2-5311; Insulation specified or installed, meets California Energy Commission (CEC) ; quality standards. Indicate type and ford. t t Sec,2-5352(f): Vapor barriers mandatory in Climate tones 14 and 16 only, t Sec.2-5317: Infiltration/Exfiltration Controls t t t a. Doors and windows between conditioned and uncondition spaces designed to limit t t air leakage. _ t t b. Doors and windows certified. ; c. Doors and windows weatherstripped; all joints and penetrations caulked and sealed. t Sec.2-5352(e): Special infiltration barrier installed to comply with Sec,2-5351 meets CEC quality standards. Sec,2-5352(d): Installation of Fireplaces 1. Masonry and factory -built fireplaces have: a, Tight fitting, closeable metal or glass door ; t t b. Outside air intake with damper and control c, Flue damper and control ; t 2. No continuous burning gas pilots allowed, ! ' t HVAC and Plumbing System Measures t t Sec,2-5352(g) and 2-5303; Space conditioning equipment sizing: attach calculations, Sec,2-5352(h) and 2-5315; Setback thermostat on all applicable heating systems. BSec.2-5316(a); Ducts constructed, installed and insulated per Chapter 10, 197E LLMC, Sec,2-5316(b): •Exhaust systems have damper controls, Sec.2-5314(c): Gas-fired space heating equipment has intermittent ignition devices, ; Sec.2-5314: HVAC equipment, water heaters, showerheads and faucets certified by the CEC. Sec,2-5352(i); Mater heater insulation blanket (R-12 or greater) or combined interior/exterior ; insulation (R-16 or greater), first 5 feet of pipes closest to tank insulated (R-3 or greater) Sec,2-5312(Exception I); Pipe insulation on steam and steam condensate return & recirc piping, Sec.2-5318(d); Swimming Pool Heating System has: 1 , a. On/off switch on heater, b. Weatherproof instruction plate on heater, c, Plumbed to allow for solar. 2. 75 percent thermal efficiency. t t 3. Pool cover, , 4. t t Time cock, , 5. Directional water inlet. Lighting and Appliance Measures ' t t , Sec.25352(j): Lighting -25 lumens/wait or greater for general lighting in kitchens and bathrooms.; ; Sec.2-5314(c): Gas fired appliances equipped with intermittent ignition devices. Sec,2-5314(a); Refrigerators, refrigerator -freezers, freezers and fluorescent lamp ballasts certified by the CEC. Indicate make and model number, Form Revised December 1987