Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
13-0685 (SOL)
r•, P.O. BOX 1504 78-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 Application Number: 13-00000685 Property Address: 51305 AVENIDA APN: - 773-044-028-8 Application description: SOLAR Property Zoning: MEDIUM DENSITY Application valuation: 28000 Tiht �� J � VOICE (760) 777-7012 FAX (760) 777-7011 BUILDING & SAFETY DEPARTMENT f INSPECTIONS (760) 777-7153 BUILDING PERMIT Date: 7/30/13 Owner: RUBIO BRIAN CORNELL -000000- LA QUINTA, CA 92253 ( RES Applicant: Architect or Engineer: Contractor: D PLANET SOLAR INC 719 EAST HALEY STREET SANTA BARBARA, CA 93103 LNo.:938313 805)2��� �� ?013 PIN. J / ___________________________________________ LICENSED CONTRACTOR'S DECLARATION _ WORKER'S COMPENSATION DECLARATION hereby affirm under penalty of perjury t Rt I licensed under provisions of Chapter 9 (commencing with I hereby affirm under penalty of perjury one of the following declarations: Section 7000). of Division 3 of the Bu s a Code, and my License is in full force and effect. _ I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided EProosonals License Class: B C46 License No.: 938313 for by Section 3700 of the Labor Code, for the performance of the work for which this permit is Date: 1 1� Contractor: issued. l have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor ..- �V Code, for the performance of the work for which this permit is issued. My workers' compensation insurance and number are: �• OWNR-8 D DECLARATION I hereby affirm under penalty of perjury that I am exem from the Contractor's State License Law for the carrier policy Carrier .COMMERCE & IND Policy Number WC001645925 following reason (Sec. 7031 .5, Business and Professions Code: Any city or county that requires a permit to. _ I certify that, in the performance of the work for which this permit is issued, I shall not employ any construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the person in any manner to com ubl ct to the workers' compensation laws of California, permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State and agree that, if I s be m s ject t the workers' compensation provisions of Section License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or 3700 of the Labor o I s 11 f rt with c mply with those provisions. that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by than five hundred dollars ($500).: (Date:'2=0/13 Applicant: ' any applicant for a permit subjects the applicant to a civil penalty of not more V'" (_) I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The WARNING: FAILURE TO SECURE WORKERS' COMPEN ATI OV AGE IS UNLAWFUL, AND SHALL Contractors' State License Law does not apply to an owner of property who builds or improves thereon, SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AN IL FINES UP TO ONE HUNDRED THOUSAND - and who does the work himself or herself through his or her own employees, provided that the DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN improvements are not intended or offered for sale. If, however, the building or improvement is sold within SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. one year of completion, the owner -builder will have the burden of proving that he or she did not'build or improve for the purpose of sale.). APPLICANT ACKNOWLEDGEMENT (_) I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. _ IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of conditions and restrictions set forth on this application. property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed 1. Each person upon whose behalf this application is made, each person at whose request and for . pursuant to the Contractors' State License Law.). whose benefit work is performed under or pursuant to any permit issued as a result of this application, ( ) I am exempt under Sec. , B.&P.C. for this reason the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City Date: Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Name: _ Lender's Address: LQPERMIT of La Qwnta, its officers, agents and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state th t ab i rmation is orrect. I agree to comply with all city and county ordinances and state laws relating t b I ng ni ruction, and ereby authorize representatives of this county to enter upon the above-mentioned p p for ns ction purposes. Date: 7 ;0 Signature (Applicant or Agent) Li'Df LQPERMIT . Application Number . . . . . 13-0000.0685 Permit ELECTRICAL 2013 Additional desc . Permit Fee . . . . 47.66 Plan Check Fee .00 Issue Date . . . . Valuation . . . . 0 Expiration Date 1/26/14 Qty Unit Charge Per Extension 1.00 23.8300 LS ELEC DEVICES, FIRST 20 23.83 1.00 23.8300 EA ELEC SERVICES 23.83 ---------------------------------------------------------------------------- Special Notes and Comments 1O.OkW SOLAR ARRAY - (40) 250W MAGE PANELS W/ (40) M215 MICRO-INVERTERS (720SF] 2010 CALIFORNIA ELECTRICAL CODE. -7 -------------------------------------------------------------------------- Other Fees . . . . . . . BLDG STDS ADMIN (SB1473) 1.00 PLAN CHECK, ELECTRICAL '35.75 PERMIT ISSUANCE M/P/E 90.57 Fee summary Charged Paid Credited ---------------------------------------- Due ----------------- Permit Fee Total 47.66 .00 .00 47.66 Plan Check Total .00 .00 .00 .00 Other Fee Total 127.32 .00 .00 127.32 Grand Total 174.98 .00 .00 174.98 LQPERMIT Bin. # City. Of .La Quin' t- a Buiiding at Safety Division P.O. Box 1504,78495 Calle Tampico 4.Quinta, CA 92253 -:(760) 777-7012 Building Permit Application and Tracking Sheet Permit # ProjectAddress: 51.3o5 Pkv exti r c.. cu.Owner's Nameo :. A. P. Number. Address: 513 OSAve,-,,V h r ck. Legal Description: Contractor G City, ST, Zip: QQ ' a GF* gZZco3 Telephone: Address: 411 _cl q S Bcaral �z� (� sk vEe IC Project Description: L( Q 5 p �. a v 40 l 4-0 City, ST, Zip: g �tn [fie s w+ 2,7_& 1 ba (o.. L") a-n r Telephone: 7Cd0-3 H l - l K 13 State Lia # : 9 3 8 3 l3City Lia #: Arcfi•. Designer ., � Address: City., ST. Zip: Telephone: State Lia #: Construction Type: j; Le c Occu 45 P�Y� Project type (circle one): New Add'n Alter Repair Darty Sq. Ft.: # Stories: # Units: Name of ContactPerson: (;��t S'i t GA'1 _( _» zc t,n z� Telephone # of Contact Person: 7(D O -7(vCo S8' I Estimated Value of Project: 2-1b ova APPLICANT: DO NOT WRITE BELOW THIS UNE N Submittal ReWd Recd TRACKNG PERMIT FEES Plan Sefs 3 Plan Check submitted � d U Item Amount Structural Cales. Reviewed, ready for corrections Plan Check Deposit. . Truss Cates. Called Contact PersonPiaa Check Balance Tithe 24 Coles. s picked up Construction Flood plata plan s resubmitted.'. Mecharilcal G:mding plan 42-�lReviewreadyioreorreefiouecout Subeontactor List ed Contact Person Plumbing Grant Deed a picked up SALL H.O.A. Approval Plans resubmitted Grading IN HOUSE:- ''d Reylew, ready for correetlonslissae Developer Impact Fee Planning Approval. Called Coataet Person AXP.P. Pub. Wks. Appr Date of permit issue School Fees Total Permit Fees bjr),I17o« How EDMO ' ,mss - Lb*b C*tX'4 AMLd *t Fay. _PARUAt*tc - WQv1iaM Rio' want 8A2*t1'*_M DaL"L#-M . it�f'�arwr�oN ad Ox.I9514tAW04*4 of st,Tb pl c: ton U1 P44 sdewt-44 .b t6 7,013 — ot-Ow 13P Ckw Lt"44� W4 J;�jnsUW-45srUAA- • ) Residential Electrical Load Calculation's Address: 51305 Avenida Rubio, La Quinta, CA. Date 6/18/2013 Owner: Brian Cornell Planet Solar Inc. Calif h 938313 General Lighting Loads Sq. Ft. 9248 x 3 Volt Amps x 27744 VA Small Appliance Load Sq. Ft. @ 1500 va each x (min of 2) 3000 VA Laundry (Washing Machine) Circuit 1500 va x (min of 1) 1500 vA 1 General Lighting Load Sub -Total 32244 VA First 3,000 VA of Lighting, Small Appliance, Laundry load at 100% 3,000 VA From 3, 001 to 120,000 VA @ 0.35 (Table 220.42) 10,235 VA Over 120,000 VA use 0.25 (Table 220.42) VA Net Load and Neutral and Feeder Calculation: 13,235 VA Fixed Appliances - if fewer than (4) units use 100%, if 4 or more use 75% of the �12oo nameplate rating 0 VA Dishwasher Water Heater 6000 VA x 1200VA x 4500VA Disposal Compactor 1 6001 x 600VA 0 VA 11200 Ix 1200VA Microwave1500 x 1500VA Clothes Dryer x5000VA Range (KW) Oven (KW) 1000 Range (KW) Oven (KW) 1000 (0,500x 715 2 Subtotal . at 100% Subtotal of (1) & (2) of General Loads or at 75% 4875 VA -0f2&5_Wr Applying Demand Factors 1s,1 10 V* First I O,000VA @ 100% 110: ,Ib/plY — Remainder @ 40% —510 p,�p ppm A Total of General Loads:. Heating or Air Conditioning @ 100% �uN Heating Units (3 or Less) VA x 65% Heating Units (4 or More) VA x 40% A/C Unit 6000 VA. x 100% A/C Unit 6000 VA x 100% Heat Pump VA x , 100% B Sub -Total of Demand and Heating/Cooling Loads: t��Tt Spare 20A x 240 Volts (Future) . rIo >�:c-, r1u� R•r-*�,� TO $G Grand Total (A) + (B) '� 9 Total Volt Amps .2 G9"ivided by 240 Volts Service Size:. 200A Grounding Electrode Conductor _*1000 l� od V 0 VA 0 VA 6000 VA 6000 VA 0 VA 12000 VA t 4800 VA + #6 = t�4s vs D6'. sw t*tca.--0c , Pbac- b* -D j'oot. LWYT .,� (Wise Ch"44 .AL4*. ,5 Cox -V-43 ATS A*1� t*tca,►�OL Poop f�trn.-ce,-lT ENPHASE AC INTERCONNECT CABLE AND s6 GROUND WIRE TO THE NEXT MICR04NVERTER INSTALL PROTECTIVE END CAP AFTER THE LAST (13TH) MICR04NVERTER ENTIRE ARRAY CONSISTS OF THREE BRANCHES: TWO BRANCHES WITH 13 MODULES AND ONE BRANCH WITH 14 MODULES FOR A TOTAL OF 40 MODULES (10,000 WATTS DC; 8,600 WATTS AC) (11,41:094W UTILITY METER # 1B4SR-112835 r - IC EXISTING ELECTRICAL 200 AMP SERVICE ENTRANCE AND LOAD CENTER _120/240 VAC_ 200 AMP BUS N �J I UTILITY GRID I SINGLE PHASE L Tronsformer # UN -3551 100 KVA C phose High 7.2KV Low 120/240V Underground Service ENPHASE AC INTERCONNECT CABLE AND 46 GROUND WIRE TO THE NEM MICR04NVERTER. INSTALL PROTECTIVE END CAP AFTER THE LAST (13TH) MICR04NVERTER INTO' S G 60694IRt- ENPHASE AC INTERCONNECT CABLE AND 06 GROUND WIRE TO THE NEM MICR04NVERTER. INSTALL PROTECTIVE END CAP AFTER THE LAST (14TH) MICR04NVFRTER ENPHASE AC INTERCONNECT CABLE NO CONDUIT fPRn.nrn RY NANIIFAm.,2FRI 215 WATT GRID-INTERRE MICRO -INVERTER (TYPICAL OF 13 PER STRING) ENPHASE M215-60-2LL-S22 � 22 - 45e VDC�O 240 VAC. I o / 8\ NO CONDUIT 215 WATT GRID-INTERTIE MICRO -INVERTER (TYPICAL OF 13 PER STRING) ENPHASE M215-60-2LL-S22 22 - 45c VDr 70.2240 VAC, 1 0 NO CONDUIT 16 BARE CU GROUNDING ELECTRODE CONDUCTOR (GEC - Run independently of other conductors and tie directly into AC grounding electrode.) No NOTES: CLE 0 EQUIPMENT SHALL BE INSTALLED IN ACCORDANCE WITH THE NEC 2008, 2010 CEC AND ALL APPLICABLE REQUIREMENTS Q7 PROVIDE' WARNING SIGN PER NEC 690.17 READING "WARNING—ELECTRIC SHOCK HAZARD—DO NOT TOUCH OF THE SERVING ELECTRIC UTILITY COMPANY AND OF THE LOCAL AUTHORITY HAVING JURISDICTION. TERMINALS—TERMINALS ON BOTH LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OFF POSITION. 33 BI—DIRECTIONAL UTILITY METER TO BE INSTALLED BY UTILITY COMPANY (WHEN REQUIRED). _ LABEL BACKFED BREAKER "PHOTOVOLTAIC POWER SOURCE" PER NEC 705.10, AND "BREAKERS 8 �9 LISTING AGENCY NAMES AND NUMBERS TO BE INDICATED ON POWER INVERTER AND SOLAR MODULES PER NEC 110.3(B). METALLIC CONDUIT SHALL BE USED WITHIN BUILDING PER NEC 690.31 (E). ARE BACKFEEDING" PER NEC690-64(B)(5). LABEL WITH THE MAXIMUM AC OUTPUT OPERATION CURRENT ® LABEL COMBINER BOX "NOTICE—DEDICATED PHOTOVOLTAIC SYSTEM COMBINER PANEL, DO NOT ADD LOADS TO THIS PANEL" AND THE OPERATING VOLTAGE PER NEC 690.54. POINT OF CONNECTION AT END OF BUSSING OPPOSITE OF MAIN BREAKER. ALABEL "PHOTOVOLTAIC SYSTEM GEC TO BE INSTALLED AS REQUIRED BY MANUFACTURER INSTRUCTIONS AND NEC 690.47. "BREAKER UTILITY DISCONNECT SWITCH". SWITCH COVER TO BE LOCKED AT ALL TIMES. LABEL HAS BEEN DE—RATED PER NEC 690.64(B)(2)". SWITCH TO BE VISIBLE BLADE AND ACCESSIBLE PER UTILITY REQUIREMENTS AND CONFORM TO NEC 705.22. LABEL AT BATTERY BANK WITH MAXIMUM OPERATING VOLTAGE, EQUALIZATION VOLTAGE AND POLARITY PER NEC 690.55. A5 LABEL "PHOTOVOLTAIC ARRAY DC DISCONNECT SWITCH" PER NEC 690.14(C)(2). LABEL WITH OPERATING ® LABEL BACKFED BREAKER "WARNING—INVERTER OUTPUT CONNECTION, DO NOT RELOCATE THIS OVERCURRENT DEVICE". CURRENT, OPERATING VOLTAGE, MAXIMUM SYSTEM VOLTAGE, AND SHORT CIRCUIT CURRENT PER NEC 690.53. SWITCH TO BE LOCKED PER NEC 690.7(D). EXISTING; CIRCUIT BREAKERS SHALL BE REMOVED FROM MAIN PANEL AND RE—LOCATED TO NEW SUBPANEL TO PROVIDE SPACE FOR NEW SOLAR CIRCUIT BREAKER. EXTEND EXISTING CIRCUITRY TO NEW PANEL AS REQUIRED. © LABEL "PHOTOVOLTAIC SYSTEM METER". OPTIONAL IF NOT REQUIRED BY UTILITY COMPANY. NOTE: NO ELECTRICAL LOAD AD ED TO MAIN PANEL WIT[ MODIFICATION. Sy6QA*l&. St Lc Ste& �4t tom.►( I` �+i Q � n-*,, � / U Q U I� U WI J W No. Revision/Issue Dote A Added details /6/1 lie Planet Solar INSTALLATION&DESIGN 41-995 Boardwalk, Suite K Palm Desert, CA 92211 760-341-1413 Contractor's Lic. # 938313 w"pn xm,,. m,a Alrom: Cornell, Brian 51305 Avenida Rubio LoQuinto, CA 92253 "-W CLE 3 of 7 5/24/13 s� N.A. AJ Ortega From: AJ Ortega ` Sent: • Thursday, June 20, 2013 12:51 PM To: 'Christian Inzunza' Subject: RE: Cornell Project Revisions 51305 Avenida Rubio Attachments: 51-305 Avenida Rubio - 2nd Review Comments.pdf Christian, reviewed the revised sheet and load calculation that you sent, please see the attached comments, and let me know if you have any question, or just include the information as requested and send me the revised sheets when ready. AJ From: cginzunza(.U)gmail.com [mailto:cginzunza0)gmail.com1 On Behalf Of Christian Inzunza Sent: Wednesday, June 19, 2013 2:00 PM To: AJ Ortega Subject: Fwd: Cornell Project Revisions 51305 Avenida Rubio Hello AJ, Attached are the revisions to the Cornell Project on 51305 Avenida Rubio. Let me know if you have 'any further questions or concerns. Regards, . Christian Inzunza 1 Address: 51305 Avenida Rubio, La Quinta, CA. Owner: Brian Cornell General Lighting Loads Sq. Ft. Small Appliance Load Sq. Ft. @ 1500 va each Laundry (Washing Machine) Circuit 1500 va Residential Electrical Load Calculations Date 6/18/2013 Planet Solar Inc. Calif h 938313 9248 x 3 Volt Amps x 27744 VA x . (min of 2) 3000 VA CO - x (min of 1) 1500 VA I General Lighting Load Sub -Total 32244 VA First 3,000 VA of Lighting, Small Appliance, Laundry load at 100% 3,000 VA From 3, 001 to 120,000 VA @ 0.35 (Table 220.42). A 10,235 v Over 120,000 VA use 0.25 (Table 220.42) VA Net Load and Neutral and Feeder Calculation: 13,235 VA Fixed Appliances - if fewer than (4) units use 100%, if U or more usez750/ Of the nameplate radiig 0 VA Dishwasher Water Heater 1200 x 1200VA Disposal x.4500VA Compactor. 600: x;600VA Microwave i5Q0 x'60*0V_A Clothes Dryer 122T_1200VA Range (KW) Range (KW) 4800 VA Oven (KW) Oven (KW) plofflo x5001)V.A: (6540 1►" 74 Applying Demand Factors voos uo: firAiY , Heating or Air'C6nditioning@'1009 Heating Units (3 or Less) Heating Units (4 or More) A/C Unit A/C Unit Heat Pump Fm C4o TOV1. �ri.yl;rL l o �r t►ISrt�ti) 2 Subtotal at 100% Subtotal of (1) & (2) of General Loads First IO,000VA @ 100% Remainder @ 40% A Total of General Loads: .6i• at 75% 4875 VA t B Il0 Ytl� VA x 65% VA x 40% 6000 VA x 100% 6000 VA x 100% VA x 100% - 8 Sub -Total of Demand and Heating/Cooling Loads: . Spare 20A x 240 Volts (Future) Grand Total (A) + (8) Total Volt Amps Service Size: a9;Q09:i+rt,+, -.1294 .11494--VA- 0 116394 uA—.. .28,$94 -Divided by 240 Volts 200A Grounding Electrode Conductor 0 VA 0 VA 6000 VA 6000 VA 0 VA 12000 VA } 4800 VA 66 3S • �G�. flDT tAIG.�."�Dc F10Dl.r ILIA-� j'eap. t>N�rt�4o (�lVts� 4k-a,wrtt.a:,u I 1401 uls ammo ffiWKne m ra�iexicuKn�owvrnu''m Wiliftp wCPwxvEmCPP [NP,IlI[ ACS G CeBIL [wxAf[ K Eti[PC01e6C1 CNP[ a-110 w ixux-a (nlpL[a BYKIaNAC11PRR1 (FPgbi< R YWufKEWCA) NnC�OxM l f Da• �fA0uX0 EMXiE APRAY CONSEISOF THREE BRANCHES mum 1N Two BPANCNEfi WRN 1JMODIILEBMIOONE IJLES WTTM HMOOIILE9 went am AVFf FORATOTALOF40M000LEB wnaf vOGya.eA1 NAW (t0.fM10 WATTS DC; B,faO WATTB AC) V�w4wivl[�(niwiUi�OrR ]� SiAWC) ENRV.Y nls-4o-riL-sit.® at -4x KKto :.o vK, T. (\r EGn.E CPgAIp w w*luno PrloalvcnRP RA ) cM+lAu K NRBcwan balA DRKa AM .n[PN1•ICCr [AEL[ a-cio w wrm-t C .g [gNyAI ca1-I w aumu (IaoM[D !n uAxVKTVRtR) (FPPVRD Br YWu— rKnww) APrtiMll BOx 1-110 Cl N L L N IlmOnro) w7a : 48„ W,41SlPOe4•S SQ,K.s eF n f�/ R-�w•l4 -. •• L C � a¢vmiaa aa.P AC SL lt1V2�.E1a- P�74.a^4.TTf0 Ul7L+ Kr spwf(r. 6 ► w1pac. u1,Aa1ro FP G w.+E lla iuiaxxL[t Y1NRONvf lfA S w.;1.fx ncl�ro,r�MPf� ra \C [ISE K .rtO6Ou6n Gam[ xg (wlovuoe. NeP1P.eiNiaq wi �u4. cwp• -- `. D. RemlC fUCINLu 1� flL SCO Alm 5[ANR [piRVKL UTILITY MEIEfl •w.wu ® ! Pv+. A. E IB4SR-112935 e1. LaK cOn[n B 1xo/t4o cK_t00 ANP eus I L L 1 4 1 0' -TY t12.a' I � � I m1M.tA :-Ifi w -Nen-x I I I ._[e w xwrPeL 1-110 w C 9 L L I 1 ®®c I N L Li -v -CJ 1 U1KnY GRID SINGLE PIUSE L I,OPfto,mo, R UN -3551 100 KVA C p — Higb 7.2KV Low 120/240V Unao1910ana Seni- t1f wen a0D-wRPIK VCN?NVCPITA ItYNCN W 1J KP StPWC) PeuY utly-fi0-lu-Saa Q 22 - 4H KK i0 t40 vK • 6 CG1M ai01AD L L N E,NMAs[ �ut4tE CNIU: (HOMED Bt YVN KIUMP) N„CnOb BOa IxBaTm) N 14% 0 N NCCIPIl 1 -//!•Ca— .D _ AC L to wen allo-NrtmP 1 uK0.0-erH" (nPKu m 14 RP ) V]IJ-80-nl-Saa /tP� tae/tP— a[nP,uBC a CMWM f.RDW� 1 •® PNDip.91. fi31[u COUBMP PN.[1 I t 00 x114. -la a rmnP.Et SaMB[-000 m/al w°p�v.°["Q® IIIL IDl ° .= ,M— a irvN�n t p J -FOIL. W AfVf, NO VK 2;&& 12. . 16 WE w CnwxaixC ELMME CwwCtOP (CFC -nun Na.nmeuuy a an•. .—I. m C. nb.aly Nle K a.•vn•N •xcOPa.) NOTES 0 EOUIPMENn SHALL BE INSTALLED IN ACCORDANCE WITH THE NEC 2008. 2010 CEC AND ALL APPLICABLE PEOUIREMENTS OF THE SERVING ELECTRIC UTILITY COMPANY AND OE THE LOCAL AUTHORITY HAVING JURISDICTION, BI-DIRECTIONAL UTRITY METER TO BE INSTALLED BY UTILITY COMPANY (WHEN REOUIRED). 3 LABEL BACKFED BREAKER "PHOTOVOLTAIC POWER SOURCE" PER NEC 705.10, AND "BREAKERS ARE BACKFEEOING" PER NEC690-64(8)(5). LABEL WITH THE MAXIMUM AC OUTPUT OPERATION CURRENT AND THE OPERATING VOLTAGE PER NEC 690.54. POINT OF CONNECTION AT END OF BUSSING OPPOSITE OF MAIN BREAKER. LABEL -PHOTOVOLTAIC SYSTEM UTILITY DISCONNECT SWITCH". SWITCH COVER TO BE LOCKED AT ALL TIMES. SVITCH TO BE VISIBLE BLADE AND ACCESSIBLE PER UTILITY REOUIREMENTS AND CONFORM TO NEC 705.22. AS LABEL "PHOTOVOLTAIC ARRAY DC DISCONNECT SWITCH" PER NEC 690.14(C)(2). LABEL WITH OPERATING CURRENT, OPERATING VOLTAGE. MAXIMUM SYSTEM VOLTAGE. AND SHORT CIRCUIT CURRENT PER NEC 690.53. SWITCH TO BE LOCKED PER NEC 690,7(D). LABEL -PHOTOVOLTAIC SYSTEM METER". OPTIONAL R NOT REOUIRED BY UTILITY COMPANY. R V. Bj ® PROVIDE WARNING SIGN PER NEC 690.17 READING -WARNING-ELECTRIC SHOCK HAZARD -DO NOT TOUCH TERMINALS -TERMINALS ON BOTH LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OFF POSITON. LISTING AGENCY NAMES AND NUMBERS TO BE INDICATED ON POWER INVERTER AND SOLAR MODULES PER NEC 110.3(8). METALLIC CONDUIT SHALL BE USED WITHIN BUILDING PER NEC 690.31 (E). LABEL COMBINER BOX "NOTICE -DEDICATED PHOTOVOLTAIC SYSTEM COMBINER PANEL, DO NOT ADD LOADS TO THIS PANEL GEC TD BE INSTALLED AS REQUIRED BY MANUFACTURER INSTRUCTIONS AND NEC 690.47. LABEL 'BREAKER HAS BEEN OE -RATED PER NEC LABEL AT BATTERY BANK WITH MAXIMUM OPERATING VOLTAGE. EQUALIZATION VOLTAGE AND POLARITY PER NEC 690.55. ® LABEL BACKFED BREAKER -WARNING-INVERTER OUTPUT CONNECTION, DO NOT RELOCATE THIS OVERCURRENT DEVICE". EXISTING dRCUR BREAKERS SHALL BE REMOVED FRO- AWN PANEL AND RE -LOCATED TO NEW SUBPANEL TO PROVIDE SPACE FOR NEW SOLAR CIRCUIT BREAKER. EXTEND EXISTING CIRCUITRY i0 NEW PANEL AS REQUIRED. NOTE: NO ELECTRICAL LOAD ADT D TO MAIN PANEL WI7 MODIFICATION. st2Z sa6M-40b170170313 .- St1ti Iro4cUaP►{ Q 0 u I� U W W w:MmA.w oc1. b0•f 4•l•ib /fi/1 PRlan�eE•465o6Nr 41-995 Boardwalk, Suite K Palm Desert, CA 92211 760-341-1413 Contractor's Lic. d 938313 Cornell, Brion 51305 AVeniBo Rubio LoQuinto, CA 92253 CLE r 5/24/13 3 of 7 N.A. lm PV INSTALLATION PACKAGE FOR THE CORNELL RESIDENCE PHOTOVOLTAIC EQUIPMENT REGUIRED WARNING 516NAGE: II 2010 CEG, 2008 NEC, CFA/LAFD MARKING5, LABELS AND WARNING SIGNS REQUIRED. A. MAIN SERVICE D15CGNNECT: CAUTION SOLAR FI Er'TRIG 5Y5TEM CONNECTED 1. Residentlal buildings - the markings may be placed within the main service service disconnect sl operablehall bwi h the service panelOn the dclosed.r if the main 2. Permanent labels shall be provided, no permanent marking pen labels shall be allowed within any main service panel 0 sub -panel. 3. Markings, verbage. Format and Type R�CEIVED of, a. verbage: CAUTION pOYqER TO TH15 BUILDING 15 AL -150 SUPPLIED FROM THE PV 5Y5TEM 5OLAR gpUR�SATED AS 5GpOI EGT MAX, 3 0 2013 ` D Format: { (1) nilte lettering On a Red Background. 1 (2) Minimum 3/8 inch letter height. m) Ail letters shall be capitalized. I� B. Marking Requirements On DC Condult, Raceways, Enclosures. Gable ' Aesembiles, DC Combiners and all ,!unction Boxes. 1. Marking Placement, verbage, Format and Type Of Materlal. a. Permanent Placement Markings shall be placed evert) Ten (10) feet On all interior and exterior DG Gondutts, Raceways, Enclosures and Gable Assemblies, at Turns, above and/or below all electrical penetrations, all pr_ Combiners and Junction BOXe5. b. verbage CAUTION 7 ' SOLAR CIRCUIT c. The following labels to be placed on all AG Disconnects: CAUTION SOLAR CIRCUIT DISC.ONNEGT FOR ` UTILITY OPERATIONS t Y SHEET INDEX 1) COVER SHEET 2) SITE PLAN 3) ELECTRICAL DIAGRAM 4) MODULE SPECIFICATIONS 5) INVERTER SPECIFICATIONS 6) AC DISCONNECT SWITCH SPECIFICATIONS 7) MOUNTING SPECIFICATIONS I GENERAL NOTES: W RNIA CODE5: WF. BUILDING CODE F. PLUMBING GORE r UF. RESIDENTIAL CODEF. 2. ENERGY GODS n1/ 2010 CALIF. MECHANICAL CODE W 2010 CALIF. ELECTRICAL GORE S. ALL EXTERIOR CONDUIT. FITTINGS AND BOXES 5HALL Be U.L. LISTED BE APPROVED FOR YIET LOCATIONS PER MEC —995Palm -BoaDeserdw lk K U All work shown on this drawing set shall be installed IS • �C 1 w ��'� undersi Ilf GOntraGtAr. D' & Sq� 4, Dete S �0 �]" 5i ne Inmm GaliPorniaLicrnx01 s t�1r'etlon . �8&i19 .6 !!31/2074 DATE / /z� I GENERAL NOTES: Initial Rel. 1. LOCAL UTILITY PROVIDER SHALL BE NOTIFIES) PRIOR TO USE AND ACTIVATION OF ANY SOLAR PHOTOVOLTAIC INSTALLATION. 2. NO SHEET METAL OR TECH 5CREY�` 5HALL BE USED TO GROUND DISCONNECT ENCLOSURE NITH TIN-PLATED ALUMINUM LUGS. Planei5olar si a PROPER GROUNDING1,GROUND BAR KIT5 SHALL BE U5ED. irrslw�mvt:v S. ALL EXTERIOR CONDUIT. FITTINGS AND BOXES 5HALL Be U.L. LISTED BE APPROVED FOR YIET LOCATIONS PER MEC —995Palm -BoaDeserdw lk K RAN TIGHT ! SHALL 9221e1 4 914.15a) ANY A,DE,0UATE 5PACING SHALL BE MAINTAINED BETr4EE l THE ROOF AND UNDER5IDE 760-341-1413 Contractor's Lic. # 938313 PLUMBING VENTS EXTENDING THROUGH 5. OF THE PV PANELS. SEPARATION DISTANCE FROM ROOF TO BOTTOM OF Pv PANELS SHALL BE A MINIMUM OF 4". PREb. DTHE CONCENTRIC r-NOCKOUTS ON THE DC SIDE OFDELECTRICAL Cornell, Brian i. SYSTEM MEC 250.q'1). BACK -FED CIRCUIT BREAKERS MUST BE AT THE OPPOSITE END OF 51305 Avenida Rubio LaQuinte, CA 92253 THE BUS BAR FROM THE MAIN CIRGUiT BREAKER OR MAIN LUGS 5UppLYING CURRENT FROM THE UTILITIE5. TO SUNLIGHT SHALL BE LISTED A5 a. ALL CONDUCTORS EXP05ED SUNLIGHT RESISTANT. SHALL BE COVERED BY °aE5/20//13 q. NO BUILDING, PLUMBING OR MECHANICAL CLE 10. THE 50LAR ARRAY. SMOKE AND CARBON MONOXIDE ALARMS REGVIRED BY CRG 8514 1 of 7 11. ALL 1EXPOSED CONDUIT SHALL BE PAINTED TO MATCH SUILDIN6 N.A. SURFACE. r .EM a NEW MAGE 250/6 MNS SOLAR MODULES 250 WATT,- TOTAL QTY: 40 (stand-off mounted: 150 tilt, 1800 azimuth angle) "- • � = - • With " NEW ENPHASE M215-60-2LLLS22 r PHOTOVOLTAIC MICROINVERTERS including . NEW PHOTOVOLTAIC SYSTEM DC DISCONNECT CONNECTIONS - - •10• _ 20 30 r 40 ;50 FEET M` NEW AC PHOTOVOLTAIC SYSTEM UTILITY AC DISCONNECT SWITCH 1 EXISTING 200A MAIN ELECTRICAL SERVICE UN -3551 ' and 100 KVA C phase High 72KV VOLTAIC SYSTEM KWH METER 1 4 (located within 1F(B�U i o I anel, if required by utility company) undergroundLow S ILDI G & SAR9 ground Service APPRQVED NEW LOAD CENTER SUBPANEL-J 'GENERAL NOTES: �. 1) UTILITY HAS 24 -HR UNRESTRICTED. ACCESS TO UTILITY DATE DISCONNECT SWITCH AND KWH METER(S). i 2) PROJECT SHALL COMPLY WITH 2010 CBC AND 2010 CEC. A V E N D A R U. B I O I I i00 t z• , • � y y - No. Revision/Issue Date A city comments) Planet Solar &.S(N.IATNaF7 R pESIGN 41-995 Boardwalk, Suite K Palm Desert, CA 92211 760-341-1413 Contractor's Lic. # 938313 Cornell, Brian 51305 Avenida Rubio LoQuinta, CA 92253 o ' CLE 2 of 7 o� 5/22/13 BAR SCALE 1 k ■ c - I ENPHASE AC INTERCONNECT CABLE AND 96 - r • GROUND WIRE TO THE NEXT MICRO4NVERTER. INSTALL PROTECTIVE END CAP AFTER THE • LAST 03TH) MICR04NVERTER ENPHASE AC INTERCONNECT CABLE ENPHASE AC INTERCONNECT CABLE 2-010 CU THWN-2 NO CONDUIT NO CONDUIT 1-g10 CU NEUTRAL (PROVIDED BY MANUFACTURER) (PROVIDED BY MANUFACTURER) 1-®10 CU GROUND JUNCTION BOX � r1/2" CONDUIT 250 WATT PV MODULE t L ENTIRE ARRAY CONSISTS OF THREE BRANCHES: (TYPICAL OF 13) - AC L TWO BRANCHES WITH 13 MODULES AND ONE BRANCH WITH 14 MODULES MAGE 25WB MNS GROUND _ FAULT FOR A TOTAL OF 40 MODULES - va 37.55 VDC.70 .IM�P°a.21 AMPS _ GFPD ° G ° (10,000 WATTS DC; 8,600 WATTS AC) - G 5 U U U U U U W No. Revision/Issue Date A Added details 6/6/13 B City comments 7/10/13 0 PfanetSolar R.'SrAILATK3NG DESIGN 41-995 Boardwalk, Suite K Palm Desert, CA 92211 760-341-1413 Contractor's Lic. # 938313 Rapti xa.•. mb AwnQ Cornell, Brian 51305 Avenida Rubio LaQuinto, CA 92253 o� 215 WATT GRID-INTERTIE - CLE 3 of 7 o 5/24/13 sm° N.A. MICRO -INVERTER (TYPICAL OF 13 PER STRING) ENPHASE'M215-60-2LL-S22 22 - 45 VDC TO 240 VAC, 1 0, - - NEGATIVE 'GROUND ' - • , ENPHASE AC INTERCONNECT CABLE AND 46 �' ♦ , - "GROUND WIRE TO THE NEXT MICRO-INVERTEFL T - - INSTALL PROTECTIVE END CAP AFTER THE -. LAST (13TH) MICR04NVERTER ENPHASE AC INTERCONNECT CABLE ENPHASE AC INTERCONNECT CABLE 2-#10 CU THWN-2 s NO CONDUIT ,, NO CONDUIT 1-#10 CU NEUTRAL {. (PROVIDED BY MANUFACTURER) (PROVIDED BY MANUFACTURER) I-810 CU GROUND " - it JUNCTION BOX L L N -- (ROOFTOP) 1/2".CONDUIT •. + DC N • "j ♦' ,. 250 WATT PV MODULE + L - . '• (TYPICAL OF 13) - - AC' - - L MAGE 25016 MNS VOC=37.70 VDC, IS( --&70 AMPS • GROUND FAULT .. • - , _ y ♦ _ ' VMP=30.55 VOC. IMP --821 AMPS FPD ° G e _ .. ♦ G - • 215 WATT GRID-INTERTIE _ - MICRO -INVERTER (TYPICAL OF 13 PER STRING) - - - ` - '• ' ENPHASE M215-60-2LL-S22 �^R\ 22 - 45 VDC TO 240 VAC, 1 0 Q = - - NEGATIVE GROUND - _ v . - - ENPHASE AC INTERCONNECT CABLE AND 96 • GROUND WIRE TO THE NEM MICRO•INVERTER. - - INSTALL PROTECTIVE END CAP AFTER THE 2 r LAST (14TH) MICR04NVERTER ENPHASE AC INTERCONNECT CABLE ENPHASE AC INTERCONNECT CABLE 2-g10 CU THWN-2, w NO CONDUIT 'aEPLAc¢ NO CONDUIT _ - 41-#10 CU NEUTRAL _ ' �w EXISIINC 2WA (PROVIDED BY MANUFACTURER) - (PROVIDED BY MANUFACTURER) ,1-V10 CU GROUND JUNCTION BOX ><Z - wvN 6RF VIER WnH n ' . 175A BREAKER TO ' NEW 125 AMP SUSPANEL , L L ROOF -TOP) 1 /2" CONDUIT N ` ( ) V w a u . FAOUTATE ADanoN DF 3-j)6 CU THWN-2 CURER HAMMER - SOLAR SACKFED 6RFARER - - + N2 _ 1-#8 CU GROUND BRG12L125RP DC N • EXISTING ELECTRICAL ' 200 AMP SERVICE ENTRANCE 1" CONDUIT (RAlocote t- W ekt. s nwn mels P-1) ® 250 WATT PV MODULE + L �p Z AND LOAD CENTER 14) - - '- AC - L o ' 120/240 VAC, 200 AMP BUS - MAGE25016MNS VO(�37.70 VDC, ISC-8.70 AMPS CRa1wD FAULT - - - - - - UTILITY METER I F - -- - l VMP=30.55 VDC, IMP -8.21 AMPS- # 184SR-112835 I Q © G — ` I I fi ' L L "N ' I 215 WATT IW2P • BREAKER o MICRO -INVERTER (TYPICAL O F 14I PER STRING) I T fi 2-b6 CU THWN-2 ENPHASE M215-60-2LL-S22 2�2P 22 - 45 VDC TO 240 VAC, 1 0 Q 1-(J6 NEGATIVE GROUND PHOTOVOLTAIC I ' I 6OA/2P I Na CU NEUTRAL 1-#10 CU GROUND SYSTEM COMBINER PANEL 'r• SDUARE-D HOM612L100R8 OR EOUNALENT 2-1y6 CU THWN-2 � T 3/4' CONDUIT - 1-g6 CU NEUTRAL (ODA. 120/240 VAC'Q® 1 -#to CU GROUND N L L IW2P - 7 Q Qj 3/4" CONDUIT s A ® C I G, L — _ _ L L I _ lrv1J I L L UTILITY GRID SINGLE PHASE L J PHOTOVOLTAIC SYSTEM UTILITY _ _ _ _ Transformer # UN -3551 DISCONNECT SWITCH (VISIBLE OPEN, NO FUSES) PHOTOVOLTAIC Q EXISTING CUTLER HAMMER DC222URS OR EQUIVALENT SYSTEM METER 6 1100 KVA C phase GROUND 2 -POLE, 60 AMPS, 240 VAC 2�.125A M 2S High 7.2KV LOW 120/240V © $6 BARE CU GROUNDING ELECTRODE CONDUCTOR (GEC - Run independently of other conductors and tie directly into AC grounding electrode.) Underground Service NOTES; Q1 EQUIPMENT SHALL BE INSTALLED IN ACCORDANCE WITH THE NEC 2008, 2010 CEC AND ALL APPLICABLE REQUIREMENTS Q7 PROVIDE WARNING SIGN PER NEC 690.17 READING "WARNING -ELECTRIC SHOCK HAZARD OF THE SERVING ELECTRIC UTILITY COMPANY AND OF THE LOCAL AUTHORITY HAVING JURISDICTION. -DO NOT TOUCH TERMINALS -TERMINALS ON BOTH LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OFF POSITON. © BI-DIRECTIONAL UTIUTY METER TO BE INSTALLED BY UTILITY COMPANY (WHEN REQUIRED). ® LISTING AGENCY NAMES AND NUMBERS TO BE INDICATED ON POWER INVERTER AND SOLAR MODULES PER NEC 110.3(B). OWER SOURCE" PER NEC 705.10, AND "BREAKERS METALSHALL WITHIN ER NEC O.31 Cj���� %%�� MAXIMUM AC LABELLICOMB NERITBOX VOT CE SDEDD GATED PHOTOVOLTAIC OLING TAIC �ANp6fHE�FJPERA41fdGq/ C569).54.POINT OFECONNECTON AT END OFOBUSSING OPPOSITE OF MAIN BREAKER. SYSTEM COMB COMBINER PANEL, DO NOT ADD LOADS 70 THIS PANEL". B£C�Qf16TddO�alCrSfSTEM iliP[ITY UfSC (��R J�' nIji����((���SIL, �CC�FT�Y/ QFP NNECT SWITCH". GEC TO BE INSTALLED AS REQUIRED BY MANUFACTURER INSTRUCTIONS AND NEC 690.47. SW L1 LE ( � JI ACCESSI SWITCH COVER TO BE LOCKED AT ALL TIMES. LE PER UTILITY REQUIREMENTS AND CONFORM TO NEC 705.22. LABEL "BREAKER HAS BEEN DE -RATED PER NEC 690.64(8)(2)". SQ LABEL "PHOTOVOLTAIC,PERA � ® LABEL AT BATTERY BANK WITH MAXIMUM OPERATING VOLTAGE, EQUALIZATION VOLTAGE AND POLARITY PER NEC 690.55. RAY DC DISCONNE T SWITCH" PER NEC 690.14(C)(2). LABEL WITH OPERATING ® LABEL BACKFED BREAKER "WARNING T, OPERATING V TBE MAXIMUM S STEM VOLTAGE, AND SHORT CIRCUIT CURRENT PER -INVERTER OUTPUT CONNECTION, DO NOT RELOCATE THIS OVERCURRENT ® EXISTING DEVICE". NEC NEC SWITCH T BE LOCKED PER IE%TlrAQFIIBX EC 690.7(D). CIRCUIT BREAKERS SHALL BE REMOVED FROM MAIN PANEL AND RE—LOCATED TO NEW SUBPANEL TO PROVIDE �53 SPACE FOR NEW SOLAR .CRCUIT BREAKER. EXTEND EXISTING CIRCUITRY TO NEW PANEL AS REQUIRED. NAL IF NOT REQUIRED BY UTILITY COMPANY. NOTE: NO ELECTRICAL LOAD ADDED TO MAIN PANEL WITH MODIFICATION. 5 U U U U U U W No. Revision/Issue Date A Added details 6/6/13 B City comments 7/10/13 0 PfanetSolar R.'SrAILATK3NG DESIGN 41-995 Boardwalk, Suite K Palm Desert, CA 92211 760-341-1413 Contractor's Lic. # 938313 Rapti xa.•. mb AwnQ Cornell, Brian 51305 Avenida Rubio LaQuinto, CA 92253 o� CLE 3 of 7 o 5/24/13 sm° N.A. ww MAGE • "�]YSOLAR ©MAGE POW ERT=C' PLUS 250 / 6 MNS PHOTOVOLTAIC MODULE Three Full Decades of Power - Guaranteed ) With our 30 -Year, 80% Power Guarantee, you can be assured top -production for 3 decades lo Industry leading 12 Year, 90% Power Guarantee High Efficiency Modules when Value Matters Most ) Only positive tolerances of up to +5 watts ensure maximum power without compromise Simple compatibility with any of our inverter partner products to achieve maximum system output Quality Tested, Service Assured Certified by the most rigorous US and International standards > 10 -Year Product Warranty > Built to withstand even the most harsh conditions Flexible Design ) Ideal for all rooftops and ground mount installations ) Easily connected to the grid or used in off -grid scenarios ) Suitable for use on ungrounded PV arrays Number of Cells: 60 Solar Cell Type: monocrystalline Power class: 250 WP YEARf �.. YF-AR90°A YEAR R WA TSPOSITIVE r PRODUCT pPOWER GUARANTEE TOLERANCES WARRANTY GUARANTEE I Ak MAGE° SO LAR Ir ®MAGE POWERT=C' PLUS 250 / 6 MNS PHOTOVOLTAIC MODULE ELECTRICAL CHARACTERISTICS Maximum Power Rating P_ IWpI 250 Tolerance of P_ P[Wp] -0/•5 lav Maximum Power Voltage of;— U,,,," M - 30.55 � Maximum Power Current P",,, I_ [AI 8.21 � -T Short Circuit Current r. Im [A] 8.70 Open Circu it Voltage Uam 37.70 r ^3 E E _ - o 0 Maximum System Voltage T M600 - _ - _, ., o Maximum Series Fuse JAI 15 ' , M1 • . STC rA7E E .2i" C. t00J V!!m'. AM I$ Eo; ui a E N n m a TECHNICAL FACTS O x N E _ Number of Cells [Matrix] 60 [6 x 101 a ^ ri o01 --.• monocrystalline n Solar Cell Type - ..w. m a Solar Cell Sire [mm] 156x 156 _- _ Solar Cell Size [inl 6 x 6 N 01 EW Dimensions'JLxWxHmm Dimensions[LaWxHmm] e.. _ 1644x992x42 Dimensions (LxWxHin] � 64.72 x 39.06 x 1.65 ;< Weightlkgl 19.0 Weight fibs]' - 41.9 _ I I� 37.09"(942mm) Module Efficiency 1%] J 15.33 �---39.06"(992mm) eoT. Connector Type MC4Equivalent DATE THERMAL CHARACTERISTICS NOCT PC] a 46 s2 4c[%/ b * 0'04 e.Temperature Coefficient Temperature Coefficient Ua(%/Kl -0'32 - c € Temperature Coefficient P,,,o[%/K] -0.43 9=2 0.414M Increases efficiency Unmatched I %.- 30-Yearandreduces S Performancecurrent losses Guarantee , . C US FSEC CEC w MAGE SOLAR USA 720 industrial Boulevard • Dublin, Georgia 31021 USA $ Toil -free (877) 311.6243 - Main Office (478) 609.6640 • Fax (478) 275.7685 info®magesolar.com•www.magesolar.com o V J Z U U W n U/ & j %. DIM, �) F Planet Solar trurrttn-la, a:x sID•1 Boardwalk, Suite K Desert, CA 92211 0-341-1413 Contractor's Lic. # 938313 Cornell, Brian 51305 Avenida Rubio LoQuinto, CA 92253 W.CLE 4 of 7 5/28/13 f N.A. ENPHASE MICROINVERTER j enphase M215 The Enphase Energy Microinverter System improves energy harvest, increases reliability, and dramatically simplifies design, installation and management of solar power systems. The Enphase System includes the microinverter, the Envoy Communications Gateway, and Enlighten, Enphase's monitoring and analysis software. - Maximum energy production PRODUCTIVE - Resilient to dust, debris and shading - Performance monitoring per module System availability greater than 99.8% RELIABLE [ - No single point of system failure SMART Quick & simple design, installation and management [ - 24/7 monitoring and analysis SAFE Low voltage DC - Reduced fire risk Y� 1 MICR61NVERTER TECHNICAL DATA Input Data (DC) M215.6o-2LL-5]1/523 M215.60.21.1.-522-NA/523-NA (Ontario) CLE Recommended maximum input power (STC) 26OW �K N.A. ' Maximum Input DC voltage 45V Peak power tracking range 22V - 36V operating range 16V- 36V MinJMax. start voltage 26 4V/45V Max. DC short circuit current 15A 1 Max. input current 10.5A _T Output Data (AC) @208 Vac -h @240 Vac I" __ Maximum output power 215W 215W Nominal output current 1.0 A• 0.9 Ae 240V/211 V -264V Nominal vohage/range 208VA 83V -229V Extended voltage/range 208V/179V-232V 240V/206V-269V Nominal frequency/range 60.0/59.3-60.5 60.0/59.3-6D.5 Extended frequency/range 60.0/59260.6 60.0/59.20.6 Power factor >0.95 >0.95 Maximum units per 20A branch circuit 25 (three phase) 17 (single phase) Maximum output fault current 1.05 Arms, over 3 cycles; 252 Apeak, 1.74ms duration .Arms at nominal voltage Ef iciency - - �o 01 CEC weighted efficiency 96.0% 96.3% BUI DING Peak inverter efficiency EN 50530) 99.8% P F Static MPPi efficiency (weighted, reference Dynamic MPPT efficiency (fast Irradiation changes, reference EN 50530) 99•9% 46mW Night time power consumption Mechanical Data DATE Ambient temperature range 40°C to +65-C Operating temperature range (intemal) -40'C to+85oC 17.3 cm x 16.4 cm x 2.5 cm (6.8' x 6.45'x 1.07 Dimensions (WxHXD) Weight - 1.6 kg (3.5 lbs) Natural convection - no fans Cooling Enclosure environmental rating Outdoor - NEMA 6 without mounting bracket Features Pairs with most 60 -cell PV modules Compatibility Communication Power line 25 -year limited warranty Warranty UL1741AEEE1547, FCC Part 15 Class 8 Compliance CAN/CSA-C22.2 NO. 0-M91, 0.4-04, and 107.1-01 osmnm h S�®Enphase Energy, Inc. C 201 to Street, Petaluma, CA 94952 C US 8777974743 www.enphase.com ® Printed an 100 Percent recycled PePer. e Revision/Issue F PlanetSolar Kgm. i f tl(hIv F. DE54N oardwalk, Suite K esert, CA 92211 —341-1413 Contractor's Lic. # 938313 Cornell, Brian 51305 Avenida Rubio LaQuinta, CA 92253 s..� CLE 5 of 7 e� 5/28/13 �K N.A. DG222URB 60A 240V 2P 3W NF N -3R Disc Eaton Cutler -Hammer Vendor..___ ------- ------------- --_..._.___.._.._...__.._._..___.................... --_.__...--.--._.._...___Eaton_Cutler�Hammer...._..__.._.._' Catalog_Number DG222URB {' ..:.._.._...___........._._..__...._..._..__.__..._._..__._.._ UPC/EANIGTIN___............. _............... ____ _.____..._._..._..---- -.._.__..__...__.00782113144238__._...._______._.__.__...._.__.._...__........ .... __..----..._.......___..___.._.--_-.._.._...___...__.__,._.._.._ Weight.-mr-un.it... ..... _........ _..... _........ ............. ... ........... _.__._.._.._.._.._...__........... 8...7_..(lbs/each)....___.._------_.._.___._.__._ ..._.._.._.._...._..__.____._..___.._.._...__....... ...... ..... .......... .---.._....-.--_-..---__-- Desori t Qn._..._.._.._......._._.__..._..._._...__._..___.._.._......._._.._.__._...__._.._..._.._..._...._...__..DCa..2 URB._60A_240V Zl?31W__...NF...N.-�R..Di$�_.._...___.__.._._..__.__._._......__..._.._.._..._.._ r U_PC_.._..._.._..___.._...----_.__......_..___..___.._..._......___...____._.-.-.--.----._.._______.._.__...---..__.782113144238----.-__.__.__.....__...__'.____.__._______._.._____._.._...___..--.-.--__...---..---._.._...___.__.._._.._ Sb Brand_......__._.._..._.___._. EATON CUTLER -HAMMER Iterr1..T.y..ep.......... _....... ._.............. _... ............................................... ___...._.._..._..__....._..__.Single Thro.W..S�fety./D sconn.ect...Switch.._.... _.................... _....._..._._._.__......... _.................... Praduct Type.___._.._.__._.._..___.....__._..___.._..._...._.._......._...._..._...._.._.._.._..__ General DutY_$a eta!_Switch_..._.._.._.------....-.---..._.._...... _.._..__._._.._...--.-_...... ---_..._.._.._.___ Distribution. E.... ui _t_- Safet. Npun.___.._.._.._....__.._.._.._....._.._..._..._._.._.._..._._._.._.._...__..___..... ................ ......... _......... _._Safety General Duty Safety; 240 V Ac Voltage; Long Description Safety Switch, 60 Ampere; Power Rating 10 HP At 240 Vac 1 Phase; 2 Pole; 2 Wire; Non Fusible Fuse; No Neutral; Nema 3R; _._.__ . __ _.. _._ _._.__.___Approyal._UI;._pG M_odel;._Ap.plGa.ile Standard..-Mema_KS-1_._.._..___ _._. _ ._._._----------.... ._. _.__. _._ .___._. _._ . _ _. __._.-. Vendor. Nam.e..._..._.._._..._.._..._......_......_......_.._...__......__._.._....._.._.._.._.._.._..._.._..._....._..Cutler�H�mmer,_Distrrbut on.._Equi.pment�Contrq_s_....... _............... _._.._.._.._ M_od_el.._..__...._.....__..._..........._._..._..... _.......... ..... ......... -._._.._..._.._..._......__._.._._.........__...._...__._DG..... .............. ...._.............. _...... __ _.._.._.._,..... ....... ........-_................... _..... ............ _....... ............ ............................... _... ... ....... -... ...................... _ _....... -.-General AC_Volta a -Ratti Ouwent_Rating..._.._......__._..._._._..._._.._.._.._...- _ ..__..._._..---------------...__._60 Am_pere..__.._.._ ------------------- -- - --_ ._._......__... - _- _._..__._.._..._. - Power.Rating............._........_..._..._.._........_._.._.._.._..__.._.._......._..._._. ....... 1...O...H P_At-240.. Vac_1_-Phase_...... ............. ........ ....... ._..._..._.........._...... ........... ...................... .... ...... _.... -......... _.._..._.... _..... _._. _............._._. _.............. _.._..___.._..._.__..._._2_......_._____.._..._ ---.____.._--.-_--.._____.......__.._---....._........_.._....._._..._...----- --_............ _._._.._.._._.__...._.__...----._..._......._-- ....__... _..... _................ ...................... _-_-..___..___...___..__..2__..._..._._______.._..____.___._______.._.____._._.__.._._....._...__..___._.._._._.____....._...__._._...__...._._.._......._.__.._._._..__........ .- Fuse._Proviso Neutral. Type.._..........--......_......_............._.._...........__....._......__._._ . ... ..... * ------------------------------- -- . ...... E n.r,l.osur._..___.._....__..__._........_. _... _. _.__._.__._._.._..._._._...__._.._......_..___.._...__._ ........... ... . 1e_m 3R__ ........ .......... _.____.__...___.._.___..._...:.._.._... ................. ..... ._._....... _.____..._.._.._..._..._._.._....._...._._._.._.._.._.._._.._..........._.._ Approval..._.._..__.._..__....._....._._.__.._.._-.__..._.._..._..--.--_.._.._.._.-.---......._.._.._...__....._..___.U.._ .... ...... _.---_-__..._..____-__.._.____._.._.._..._.._._....... ..-...... ........ .... ___._...-----..._.._........__....---..._..._._.___...__..._...__..__..._.._ A —d.it QnaLInform-at ion__._....._.._..__.___..._.._._.___._.._.._.._.___..._Ap.plicable_Sta.ndard Nema KS.-1.__.._...__..._._.._.._..__..__.__._._...__..__..__._.._._..._..__ UU U U U UU U W 7 U U U 0 t BUILDING &®p✓ A k ^ FETY DEPT. A.&vj9ion/Issue Dote 99 i 71 Initial Rel. DATE ��P` •I MISt:.I VR1CN.tiDtSrM 41-995 Boardwalk, Suite K Palm Desert, CA 92211 760-341-1413 Contractor's Lic. # 938313 Cornell, Brian 51305 Avenida Rubio LoQuinta, CA 92253 a`- _*CLE Sb 6 of 7 oma. 5/28/13 s� N.A. r'A TILE TRAC @ PHOTOVOLTAIC MOUNTING SYSTEM TILE TRACOATTACHMENT BASE TO BE SECURED TO RAFTERS W1 5116° LAG BOLTS AND MASTIC: SIKAFLE) ° PREFERRED TILE I SLIDING CARRIAGE �5116'XY e LAG BOLT TILETRAC° o FLASHABLE ROOF STANCHION I: 3/8'X6'/ THREADED - STUD FOR TILE ROOF DRILL 318' HOLE IN TILE WITH MASONRY BIT FOR THREADED STUD, REPLACE TILE, APPLY SEALANT AROUND STUD AND COMPRESS WI 318° WASHER RAFTER ATTACHMENT DETAIL 3 TILETRAC® ATTACHMENT DETAIL 4 TILETRAC7 IS ATRADEMARK OF PROFESSIONAL SOLAR PRODUCTS C Sub -Total of Demand Pool/Spa Loads: 1800 VA Grand Total (A) + (B)+© 36,710 VA Total Volt Amps 36,710 Divided by 240 Volts 153.0 Amps Service Size: 200A Grounding Electrode Conductor • #6 BU9L�Jl�1G SAVETY �P rl�v a�FICE rop � Residential Electrical Load Calculations Address: 51305 Avenida Rubio, La Quinta, CA Date 7/29/2013 Owner: Brian Cornell Planet Solar Inc. Calif h 938313 General Lighting Loads Sq. Ft. 9248 x 3 Volt Amps x 27744 VA Small Appliance Load Sq. Ft. @ 1500 va each x (min of 2) 3000 VA Laundry (Washing Machine) Circuit 1500 va x (min of 1) 1500 VA 1 General Lighting Load Sub -Total 32244 VA First 3,000 VA of Lighting, Small Appliance, Laundry load at 100% 3,000 VA From 3, 001 to 120,000 VA @ 0.35 (Table 220.42) 10,235 VA Over 120,000 VA use 0.25 (Table 220.42) VA Net Load and Neutral and Feeder Calculation: 13,235 VA Fixed Appliances - if fewer than (4) units use 100%, if (4) or more use 75% of the nameplate rating Dishwasher 1200 x 1200VA Disposal 600 x 600VA Water Heater x 4500VA Compactor 1200 x 1200VA Microwave 1500 x 1500VA Clothes Dryer x5000VA Range (KW) Oven (KW) 1000 Range (KW) Oven (KW) 1000 2 Subtotal at 100% or at 75% 4875 VA Subtotal of (1) & (2) of General Loads 18,110 VA Heating or Air Conditioning @ 100%, Heating Units (3 or Less) VA x 65% 0 VA Heating Units (4 or More) VA x 40% 0 VA A/C Unit 6000 VA x 100% 6000 VA A/C Unit 6000 VA x 100% 6000 VA Heat Pump VA x 100% 0 VA B Sub -Total of Demand and Heating/Cooling Loads: 12000 VA Spare 20A x 240 Volts (Future) 4800 VA Pool and Spa @ 100% Pool Pump Unit 1800 VA x 100% - 1800 VA C Sub -Total of Demand Pool/Spa Loads: 1800 VA Grand Total (A) + (B)+© 36,710 VA Total Volt Amps 36,710 Divided by 240 Volts 153.0 Amps Service Size: 200A Grounding Electrode Conductor • #6 BU9L�Jl�1G SAVETY �P rl�v a�FICE rop �