Loading...
14442 (SFD)f Building 52-100 Ave. Rubio Addfess Owner James Belknap Mailing p.C• Box 297 Address City Zip Palm Desert o, r 922€ 0 Con ractarp Construction Address 44 P.O. BOX 1504 No. 14442 78-495 CALLE TAMPICO LA OUINTA, CALIFORNIA 92253 Tel. ' City Zip Tel.: State Lic. & Classif. B 652815 City Lic. # 2845 ' Arch., Engr., Designer Address Tel. City . ... /,. . Zip State Lic. # (1 LICENSEQCONTRACTOIPSDECLARATION I herebyy`affirm, that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of tivision 3 of the Business addProfessions Code, and m'�j license is in full force and A GNATURE DATE r ! OWNEWBUILDER DECLARATI 14 -7-- I ' I hereby affirm that I am exempt from the Contractor's License Law for the following • reason: (Sec. 7031.5,Business and Professions Code: Any city or county which requires a permit to construct, after, improve, demolish, or repair any structure, prior to its issuance also requires the applicant for such permit to file a signed statement'that he is licensed pursuant to the provisions of the Contractor's license Law, Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, or that. he is exempt therefrom, and the basis for the alleged exemption. Any violation of Section 7031.5 by 'any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500). ❑.I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not Intended or offered for sale. (Sec. 7044, Bulsness and Professions Code:. The Contractor's License law does not apply to an owner of property who builds or improves thereon and who does such work himself or through his own employees, provided that such improvements are not intended or offered.for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he did not build or improve for the purpose of sale.) • ❑ I, as owner of the property, am exclusively contracting with licensed. contractors to con- struct the project. (Sec. 7044; Business and •Professions Code: The Contractor's License Law does not apply to an, owner of property who builds or improves thereon, -and who contracts for such projects with a contractor(a) frcensed pursuant to the Contractor's License Law.) , ❑ 1 am exempt under Sec B. & P.C. for this reason Date Owner WORKERS' COMPENSATION DECLARATION I hereby affirm that I have a certificate of consent to self -insure, or a certificate of worker's Compensation Insurance, or a certified copy thereof. (Sec. 3800, Labor Code.) Policy No. Company ❑ Copy is filed with the city. ❑ Certified copy is hereby furnished. CERTIFICATE OF EXEMPTION FROM WORKERS' COMPENSATION INSURANCE (This section need not be completed if the permit is for one hundred dollars ($100) valuation or less.) I certify that in the performance of the work for which this permit is issued, I shall not employ anyparson In any manner so as to become subject to the Workers'. Compensation Laws of California Date Owner NOTICE TO APPLICANT: n, alter. making this Certificate of Exemption you - should become subject to the Workers' Compensation provisions of the -Labor Code, you must forthwith comply with such provisions or this permit shall be deemed revoked. ' WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND . SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES'UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000), IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. This is abuilding permit when properly filled out, signed and validated, and is subject to expiration if work thereunder is suspended for 181 days. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives -of this city to enter the above-.. mentioned property for Inspection purposes. Signature of applicant Date Mailing Address City, State, Zip BUILDING: TYPE CONST. OTB OCC: GRP. R3 A.P. Number 773-223-005 Legal Description Lot • 18 Block 3 Project Description' ZONE: BY: Minimum Setback Distances:' Front Setback from Center Line• Rear Setback from.Rear Pro Side Street Setback from nn r Line 1 Side Setback from Prop Ine FINAL DATE INSCTOR '- Issued by: Date ` Pe/m1( Validated by: Validation: /I // Sq. Ft. I400 Size No. No. Dw. Stories Units New ❑ Add ❑ Alter ❑ Repair ❑ Demolition ❑ Permit does not include block walla or pool • . . Estimated Valuation$5 r �5 • PERMIT' AMOUNT Plan Chk. Dep. 4:1111,11_ ~_ Plan.Chk: Bal. �_ • Const. .y I q 0 4V � Mech. 5 • JV Electrical t2t • Plumbing S.M.I.1. a Grading 00 Driveway Enc. _ • 7D ~ Infrastructure e �'vu w . Pr_v�.a:a� xY s. � xi TOTAL 3;326.6034 32.as 3 0760 . o 3 1 , REMARKS ZONE: BY: Minimum Setback Distances:' Front Setback from Center Line• Rear Setback from.Rear Pro Side Street Setback from nn r Line 1 Side Setback from Prop Ine FINAL DATE INSCTOR '- Issued by: Date ` Pe/m1( Validated by: Validation: /I // I ' / CONSTRUCTION ESTIMATE NO. ELECTRICAL FEES NO. PLUM FEES. 1ST FL. SO. FT. ® $ 2ND FL. SQ. FT. POR. SQ. FT. ® GAR. SQ. FT. ® CAR P. SQ. FT. WALL SO. FT. SO. FT. ® ESTIMATED CONSTRUCTION VALUATION $ UNITS MOBILEHOME SVC. POWER OUTLET YARD SPKLR SYSTEM BAR SINK ROOF DRAINS DRAINAGE PIPING DRINKING FOUNTAIN URINAL WATER PIPING NOTE: Not to be used as property tax valuation HEATING (ROUGH) FLOOR DRAIN MECHANICAL FEES FORMS WATER SOFTENER VENT SYSTEM FAN EVAP.000L HOOD SIGN WASH ER(AUTO)(DISH) APPLIANCE DRYER GAS (ROUGH) METER LOOP GARBAGE DISPOSAL FURNACE UNIT WALL FLOOR SUSPENDED OTHER APPJEOUIP. LAUNDRYTRAY AIR HANDLING UNIT CFM FINAL INSP. KITCHEN SINK ABSORPTION SYSTEM B.T.U. TEMP USE PERMIT SVC WATER CLOSET' COMPRESSOR HP POLE,TEMIPERM LAVATORY HEATING SYSTEM FORCED GRAVITY AMPERES SERV ENT SHOWER BOILER B.T.U. SO. FT. ® c BATH TUB SQ. FT. ® c WATER HEATER MAX. HEATER OUTPUT, B.T.U. SQ. FT. RESID ® 11/4 c SEWAGE DISPOSAL � '7-C SQ.FT.GAR ® 3/4c HOUSE SEWER GAS PIPING PERMIT FEE PERMIT FEE PERMIT FEE DBL TOTAL FEES MICRO FEE MECH.FEE PL.CK.FEE CONST. FEE ELECT. FEE SMI FEE PLUMB. FEE STRUCTURE PLUMBING ELECTRICAL HEATING & AIR COND. SOLAR SETBACK VZjo GROUND PLUMBING /wDERGROUND A.C. UNIT COLL. AREA SLAB GRADE ROUGH PLUMB. BONDING HEATING (ROUGH) STORAGE TANK FORMS SEWER OR SEPTIC TANK ROUGH WIRING DUCT WORK ROCKSTORAGE FOUND. REINF. GAS (ROUGH) METER LOOP HEATING (FINAL) OTHER APPJEOUIP. REINF. STEELGAS (FINAL) / 3 /JWMP. POLE FINAL INSP. GROUT WATER HEATER SERVICE BOND BEAM WATER SYSTEM GRADING cu. yd. $ plus x$ _$ LUMBER GR. FINAL INSP. FRAMING �/ G/S FINAL INSP. ROOFING l 1jL / ' �✓�/�Sf /,�i%l'/%� ��Z-� -rJ.� G�✓,�Z�T1�T� /9 ',/� I , / W' V l •� REMARKS •" j VENTILATION 0 � '7-C STi' .:a z./C eW 0 FIRE ZONE ROOFING FIREPLACE SPARK ARRESTOR\ A ON 0 T %. S � - 1s1 /��d C.L ✓" �.� .A, : GAR. FIREWALL a � LATHING /G //S MESH IL INSULATION/SOUND FINISH GRADING g FINAL INSPECTION CERT. OCC. 3 /5 FENCE FINAL INSPECTOR'S SIGNATURESIINITIALS GARDEN WALL FINAL 1 DESERT SANDS UNIFIED SCHOOL DISTRICT \ ' 82-879 Highway 111 1 NOTICE: Indio, CA 92201 Document Cannot Be Duplicated 619-775-3500 Date 112/13/941 Type of Permit I La Quinta No. 113226 1 Permit # Owner Name James Belknap Log No. 52-100 Street Ave. Rubio city La Quinta Zip 92253 Study Area 115 APN # Tract # Lot # 0 Square Footage 11400 Type of Development Single Family Residence No. of units 0 Comments At the present time, the Desert Sands Unified School District does not collect fees on garages/carports, covered patios/walkways, residential additions under 500 square feet, detached accessory, structures or replacement mobilehomes. It has been determined the above-named owner is exempt from paying school fees at this time due to the following reason: EXEMPTION NOT APPLICABLE This certifies that school facility fees imposed pursuant to Government Code 53080 in the amount of 1.72 x 1400 or $ 2,408.00 have been paid to D.S.U.S:D. for the property listed above and that building permits and/or Certificates of Occupancy for this square footage in this proposed project may now be issued. Fees Paid By James C. Belknap, Jr. Telephone 341-2271 Name on the check By Dolores A. Ballesteros i Superintendent I Fee collected /exempted by Mary Lou Lopez Payment �Roceived\ fi Signature _ ' -tyhebk No1130 Collector: Attach a cop of county or city pl �ck application form to distric jcopy for all`wavers. Embossed Original- Building Dept./Applicant Copy - Applicant/Receipt Copy�- Ati o nting SENT BY: XEROX Telecopier 7017:10-13-94 :12:OOPM 6197739289 1 ' ku/141 V4 itc40 rAS VUtr 187 50'/Z lal' AMAIVAV Tl'L 10002/110E Order No. E:.crcw No. 2-18333 b L car. No. ! •� �O' not �.%IHEN RECORDED MAIL TO: p nex.. lralP;es C. Bw1kr1AP, Jr - r.':';1500 tl, '73 5 0 0Fiddleneck LATle Dae>art, CA 92260 a ��t. v�1�1`l�yl, }` + . y gr a CoU'''�� 1 A Br onfV, Crofi 8' -ATE OF CALI�RNIA SPACE WOVE TH!8 UNE POR RECORIMRS Ufa ----. -AX S1'ATEMENT3 T0. 38 70 DOCUMENTARY TRANSFER TAX .,.,.•s...,,.......................... ;a pro ?!.computed an the consideratian Or velus of pmparty oonvsy d; OR e as above.. ,,,,,Computed an the oonsideration or value lase Hens or encumbrances rs!rriaihing at time of sale Foresiter Escrow, Inc. — ho-) en.tun o adarant or ^gem cammaninv Gm�rrT+ ams -.P,W 773-223-005 TRA: GRANT DEED !=0R AVALUABLE CONSIDERATION, receipt of which is hereby acknowledged, r ERADOPI W. CRoFF and CARLA CROFF, husband and wife nereby GRANT(5) to JANSS C. BELKHAP, JR., Trustee of 2`fl$ JAMES BEWUP SEPARATE TRUST, dated' May 5, 1992 ` the real property In the City of L° Qu ° State of Catlfomla, desertbed ee Ocunty Of Riverside Lot Se, 010ak 3, Baat.A 02=011tn at Yale T,a in the Qtsinta, omit No. Ii As per atmp Office of the Countb Retarder ( rwordad in Boat 18, page 46 of Nage, of Riverside County. aember 28, 1994 Da:c Set: 1 } Br onfV, Crofi 8' -ATE OF CALI�RNIA C_1UNTY OF } Before me, / r1 ;a pro 'u,montlbj apppeared • Bradak W. crotf and Carla Croft - (or pmad to me an the basis of eabdaaimY R evidence) to be the persons) whoira narngs) Mitre subtptbed to the oessNessase0Soease ess+ereseeesee�e Z HAIL KENNEDY within Instrument and achrohvledged to me that htlsheAhay eaaouted the EUZABEiN S same in hlslherhheir errlhortzed ppadty(iee), and that by hlalhor"? COMM, N1018216 S p' j7 k ttlgTARY P17fltlC • t;ALirDnNtA s.gnau:re(s) an tho tnswm nt the Darm(S) or tht entity upon behotr or ( fi48Rt1Dt COUNYtl } tAy Oonwrr. ted+M tstxwry 91, teas s S whicA the Persrlaouted "I atn mni on sees�sesseessuessveseersseseessese00 vvriNE88 and PIS Sites for oftial WSW aril) Signature - AIL`Tr�i�.S'iAT r�1CvTS`AS-DIP.EC?EO-AEinVE.. _ 1002(1194) 1 r r e OFFICE OF THE AGRICULTURAL COMMISSIONER CALVIN C. I(AMwsXAs Assistant Corrxnissloner P.O. BOX 1089 C"O" A.00 ' RIVERSIDE CA 92502-1089 DAN RILEY '. JAMES O. WALLACE PHONE (909) 275-3000 Sealer, weights & Measures Agricultural commissioner FAX (909) 275-3012 Director of Weights & Measures (909) 275.3030 FAX (909) 276-4728 83-612 Avenue 45 Suite 7 Indio, CA 92201 (619)863-8291 DATE 6 CASE NO. vt C13 t ( �2 3 V / - DEVELOPER'S NAME: Af ADDRESS: V P .10 TELEPHONE: Dear Developer: After reviewing your landscaping plans, all plant material listed is not :in violation of quarantine laws governing the .Coachella Valley.. If substitutions, -..do occur and they differ from plant material listed, this office must be notified immediately. Thank you for protecting and preserving the Coachella Valley's pest -free environment.. AgricuItur Comm issioner's*Office cc: Indio. and Riverside ;Ij (�z V 0 1 Orrr,1%.L Tit'Vf ka-.011thita This Certificate issued pursuant to the requirements of Section 306 of the Uniform Building Code certifying that at the time of issuance this. structure was in compliance with the various ordinances of the City regulating building construction or use. For the following: BUILDING ADDRESS 52-100 Avenida'Rubio Single Family Dwelling 14442 Use Classification Bldg. Permit No. Group R3 Type Construction VN, Fire Zone Use Zone SR Owner of Building James Belknap Address P-0- Rc)x 2()7 City La Quinta , CA 92 2 S 3 By; Daniel P. Crawford Jr. Date; March 15, 1995 Building Officip'l POST IN A CONSPICUOUS PLACE TITLE 24 REPORT FOR: BELNAP CONSTRUCTION LA 9UIENTA, CALIF. PROJECT DESIGNER': BELNAP CONSTRUCTION REPORT PREPARED BY: GINA'TROOLINES MJT Constructiron Services 4277 Main St. Riverside, Calif. 92501-3822 (909) .369-1700 Job Number 5205-2 Date:' 11/2/1994 The COMPLY 24 computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential Building Energy Efficiency Standards. I IIA. 1 Vyl QI11 VGVG1Vj•+GV Vj l.IfR VC:l VVIAIA• -+e-Q-VOVJ Table Of Contents for Title 24 Report ------------------------------------- Cover Page ....... ....................... ... 1 Table of Contents ...... ..... 2 Form CF -1R Certificate of Compliance: Residential ... 3 Form'MF-1R Mandatory Measures Checklist: Residential ................. 5 Form C -2R Computer Method Summary .............. .. 7 Form P -2R Point .System Summary ....:.. ...... . 1'0 HVAC Zone &.Space Loads Summary ..._......................... ... ... 11 CERTIFICATE OF COMPLIANCE; Residential (part 1 of 2) CF -1R* page'3 of 13 Project Name: BELNAP CONSTRUCTION o.Date: 11/2/1994 Address: o LA 9UIENTA, CALIF. 6Building Permit No' o Designer: BELNAP CONSTRUCTION 6Checked by /'Date 6 Documentation: MJT Construction Services 6COMPLY 24 User 1160 GENERAL INFORMATION Compliance Method:. COMPLY 24 version 4.10 Climate Zone: 15 Conditioned•Floor Area:" 1400 sqft Building Type: Single Fam Det Building Front Orientation: 270 deg (W) Number of Dwelling Units:' 1 F1oor.Construction Type:. Slab on Grade BUILDING SHELL INSULATION Component U -Value Location/Comments R-13 Wall w/1" EPS ,0.059 WHOLE HOUSE R-38 Roof(R.38.2xl4.16) 0.028 WHOLE HOUSE Slab Perimeter w/R-0.0 0:900 WHOLE HOUSE Slab Perimeter w/R-0.0 0.720 WHOLE HOUSE FENESTRATION Shading Devices Frame Orient. Area U -Val Type Interior" Exterior OH SF Type Left (N), 44.0 0.72 Double Std Drape Standard Bug Scr N N Metal `Back (E) 2'117.3 O.72 Double Std Drape' Standard Bug Scr' N N Metal Right (S) 10.3 0.72 Double Std Drape'- Standard Bug Scr N' N Metal.. Front, (W) 16.0 0.72 Double Std -Drape-. Standard Bug Scr N N Metal Front (W) 4.0 0.75 Double Std Drape Standard Bug Scr Y' 'N Meta'l Skylight 12.0 0..80 Double ' ' none - 'none N N Metal - THERMAL MASS `Area Thick Type Covering (sf) ;(in) • Location/Description Concrete, Heavyweight Exposed 1673 ',3.50 Slab on Grade Concrete, Heavyweight Covered, 727 3:50 'Sl,ab on Grade CERTIFICATE OF COMPLIANCE: Residential (part 2 of 2) CF -1R page 4 of 13 ---------------------------------- ---------------------------------------- Project Name: BELNAP CONSTRUCTION 6Date: 11/2/1994 6 Documentation: MJT Construction Services 6COMPLY 24 User 1160 ---------------------------- ---------------------------------------------- HVAC SYSTEMS Minimum Distrib Type', Duct TStat System Type Efficiency --------------------- and Location ---------------- RVal Type ---- ------ Location/Comments ----------------------- PackHtPump 6.600 HSPF Ducts in Attic 4.2 SetBck WHOLE HOUSE PackHtPump 12.000 SEER Ducts in Attic 4.2 SetBck Water No. Tank Ext. WATER HEATING SYSTEMS Heater in Energy Size Insul System Name Distribution Type Type Sys Factor (gal) R -Val ,Std Gas 50 gal or Less Standard StorGas 1 0.53 50.0 12.0 AFUE WATER HEATER EQUIPMENT DETAIL /Rec Rated Stdby Tank Pilot System Name System Type ' Eff Input Loss R -Val Light Std Gas 50 gal or Less DomesticHW 0.760 40000 0.040 0.0 0 SPECIAL'FEATURES/REMARKS COMPLIANCE STATEMENT This Certificate of Compliance lists the building,features and'performance specifications needed to comply with Title 24, Parts 1 & 6 of the Califor- nia Code of Regulations, and the administrative regulations to implement them. This 'certificate has been signed by the individual with overall design responsibility. When this certificate of compliance is submitted for a single building plan to be built in multiple orientations, any shading feature that is varied is indicated in the Special Features/Remarks section DESIGNER or OWNER (Per Business & Professions Code) BELNAP CONSTRUCTION, Lic signatu-lule ) /( date ) ENFORCEMENT AGENCY Name: Title Agency: Telephone' DOCUMENTATION AUTHOR GINA TROOLINES MJT Construction Services 4277 Main St. Riverside,'Calif. 92501-3822 ( 909,1 369-1700. ( signature ) ( date ) (signature/stamp) ( date ) MANDATORY MEASURES CHECKLIST (part 1 of 2) MF -1R page 5 of -13 -----------------------------------------------------------------7--------- Project Name: BELNAP CONSTRUCTION 6Date: 11/2/1994 6 Documentation: MJT Construction Services 6COMPLY 24 User 1160 ---------------------------------------------------- ------------------------ I Lowrise residential buildings subject to the Standards. must contain these measures regardless of the compliance approach used. Items marked -with an asterisk (*) may be superseded by more stringent compliance requirements listed on the Certificate of Compliance. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as binding minimum` component performance specifications for the mandatory measures whether .they'are shown elsewhere in the documents or on this checklist only. BUILDING ENVELOPE MEASURES o 'Sec . 150(a): Minimum R-19 ceiling insulation. * o Sec. 150(b): Loose fill insulation manufacturers labeled R -Value. ' o Sec. 150(c): Minimum R-13 wall insulation in framed walls (does not apply to exterior mass walls). o Sec. 150(d): Minimum R-13 raised floor insulation in framed floors; Minimum R-8 in concrete raised floors. * o Sec. ,150(1): Slab edge insulation - water absorption rate no greater than 0.3%, water vapor transmission rate no greater than 2.0 perm/inch. o Sec.'118: Insulation specified or installed meets California Energy Commission quality standards- Indicate Type & form. Enforcement o Sec. 116-117: Fenestration Products, Ext Doors & Infil/Exfil Controls a. Doors and windows between conditioned and unconditioned spaces designed to limit air leakage., b. Manufactured fenestration products have label w/certified U -Value c. Exterior doors and windows weatherstripped; all joints and penetrations caulked and sealed. o Sec. 150(9): Vapor barriers mandatory in Climate Zones 14 and 16 only. ; o Sec. 150(f): Special, infiltration barrier' installed to .comply with Sec. 151 meets Commission quality standards. o Sec. 150(e): Installation of Fireplaces, Decorative Gas Appliances and Gas Logs 1. Masonry and factory -built fireplaces have a. Closeable metal or'glass door b. Outside air intake with.damper and control c. Flue damper and control 2. No continuous burning gas pilots allowed. MANDATORY MEASURES CHECKLIST (part 2 of.2). MF -1R page 6 of 13 --------------------------------------------------------------------------- Project Name: BELNAP CONSTRUCTION 6Date: 11/2/1994 6 Documentation: MJT Construction Services 6COMPLY 24 User 1160 SPACE CONDITIONING, WATER HEATING AND PLUMBING SYSTEM MEASURES Enforcement o Sec. 110-13: HVAC equipment, water heaters, showerheads and faucets certified by the Commission. o Sec. 150(i): Setback thermostat on all applicable heating systems. o Sec. 150(j): Pipe and Tank Insulation 1. Indirect hot water tanks ('eq unfired storage tanks or backup solar hot water tanks) have -insulation -blanket (R-12 or greater) or combined interior/exterior insulation (R-16 or, greater) . . 2. First 5 feet of pipes closest to water heater tank, non -recirculation systems, insulated (R-4 or greater. 3. All buried or exposed,piping'insulated in recirculation sections of hot water system. 4. Cooling'system.piping below 55 F`insulated. 5. Piping insulated between heating source and indirect hot water tank. o Sec. 150(m) Ducts and ' Fans * ' 1. Ducts constructed, installed and sealed to comply with UMC Sections 1002 and 1004; ducts insulated to'a minimum R-4.2 or ducts enclosed entirely within conditioned space. 2. Exhaust systems have backdraft or automatic dampers. 3. Gravity ventilating systems serving conditioned space have either automatic or readily accessible manually operated dampers. , o Sec. 114:•Pool and Spa Heating Systems and Equipment 1. System is certified with 78% thermal efficiency, on-off switch, weatherproof operating instructions, no electric resistance heating and no pilot light. 2. System is installed with:. a. At least 36" pipe.between filter and heater for future solar heating. b. Cover for outdoor pools or outdoor spas. 31. Pool system has directional inlets and a circulation pump time switch. o Sec. 115: Gas-fired central furnace, pool heater, spa heater or household cooking appliance have .no continuously burning pilot light. (Exception: Non-electrica-1 cooking appliance with pilot < 150 Btuh) LIGHTING MEASURES o Sec. 150(k): Lighting - 40 lumens/watt or greater for general lighting in kitchens and rooms with water closets; and recessed ceiling fixtures IC (insulation cover) approved. COMPUTER 'METHOD• -SUMMARY (part 1 of 3) C -2R page 7 of 13 --------------------------------------------------------------------------- Project Name: BELNAP CONSTRUCTION _•6Date: 11/2/1994 Documentation: MJT Construction Services 6COMPLY 24 User 1160 -------------------------------------------------------=------------------- POINT SYSTEM COMPLIANCE SUMMARY Proposed Design Point Score 0 Points *Building Complies* Budget Compliance -Point Goal 0 Points GENERAL INFORMATION Compliance Method: COMPLY 24 version 4.10 Climate Zone: 15 Conditioned Floor Area: 1400 sqft Building Type: Single.Fam Det .Building Front Orientation: 270 deg (.W) Number of Dwelling Units: 1 Number of Stories: 1 Floor Construction Type: Slab on Grade Total Conditioned Volume: 14000 cuft , Conditioned Footprint Area: 1400 sqft Ground Floor 'Area: 1400 sqft BUILDING ZONE INFORMATION Floor # of Vent Zone Name Area Volume.Units Zone Type TStat Type Mgt Area. WHOLE HOUSE 1400 `14000 1.00 Conditioned Setback 2 n/a OPAQUE SURFACES'Act Solar Type Area U -Val Azm Tilt Gains ---- ---- ----- --- ---- ----- Form 3 Reference Location/Comments ZONE NAME = WHOLE HOUSE ----------------------- ' -- --------------,---- Wall 380 0.059 270 y90 Yes R -13 -Wail w/1°.EPS WHOLE HOUSE Wall 283.0.059 90 90 Yes R-13 Wall w/1" EPS WHOLE HOUSE Wall 470 0.059 180 90 Yes R-13 Wall w/1" EPS WHOLE HOUSE Wall 436 0.059 0 90 Yes R-13 Wall w/1" EPS WHOLE HOUSE Roof 1388 0.028 90 22 Yes R-38 Roof(R.38.2x14.16) WHOLE HOUSE r s. COMPUTER METHOD SUMMARY (part 2 of 3) C -2R page 8 of 13 --------------------------------------------------------------------------- Project Name- BELNAP CONSTRUCTION 6Date=,'1'1/2/1994 0 Documentation= MJT Construction Services 6COMPLY 24 User 1160 PERIMETER LOSSES F2 Insulation Type Length Factor R -Val, Depth Location/Comments ZONE NAME = WHOLE HOUSE Exposed 203.0 0.90 0.0 0 in WHOLE HOUSE Covered 176.0 0.72 0.0 0 in WHOLE HOUSE FENESTRATION SURFACES Sc Act Glass # ,Type Area Frame Div U -Val Azm Tilt Only Location/Comments ZONE,NAME = WHOLE HOUSE 1 Wdw-Front (W) 16.0 Metal No 0.72 270 90 0.88 WHOLE:HOUSE 2 Wdw Front (W) 4.0 Metal No 0.75 270 90 0..88 WHOLE,HOUSE 3 Wdw Back (E) 117.3 Metal No 0.72 90, 90 0.88 WHOLE HOUSE 4 Wdw Right (S) 10.3 Metal No 0.72 180 90 0:88 WHOLE HOUSE 5 Wdw_Left (N) 44.0 Metal No 0.72 0 90 0.88 WHOLE HOUSE 6 Sky Back (E) -12.0 Metal No 0.80 90 0 0.88 WHOLE HOUSE INTERIOR & EXTERIOR SHADING # Type Interior Shade Type SC Exterior Shade Type SC 1 Wdw Std Drape 0.78 Standard Bug Screen 0.87 2 Wdw Std Drape 0.78 Standard Bug Screen 0.87 3 Wdw Std Drape 0.78 Standard Bug Screen 0.87 4 Wdw Std -,Drape 0.78 Standard Bug Screen 0.87. 5 Wdw Std Drape 0.78 Standard Bug Screen 0.87 6 Sky None 1.00 None 1.00 COMPUTER METHOD SUMMARY (part 3 of 3) C' -2R page 9 of 13 Project Name: BELNAP CONSTRUCTION 6Date: 11/2/1994 Documentation.: MJT Construction Ser'v'ices 6COMPLY'24 User 1160 -------------------------------------------------------------- OVERHANGS/SIDE FINS --Window-- ----- Overhang ------- ---Left Fin-=- ---Right Fin-- # Type Ht Wd Len Ht LEx.t RExt Dist Len Ht Dist Len Ht 2 Wdw 2.0 2.0 4.0 0.1 4.0 4.0 THERMAL MASS --Area Thick :Heat,- Inside Location Type (sf) (in) Cap Cond Form 3 Reference R -Val . Comments y - ZONE NAME = WHOLE HOUSE Exposed Slab 673 3.50 28 •0.98 n/a 0 Covered Slab 727 -'3,.50 28, 0.981 n/a .2 HVAC SYSTEMS Minimum Distrib Type Duct TStat System Type Efficiency.and Location RVal Type Location/Comments PackHtPump 6:600 HSPF Ducts in Attic 4.2 SetBck WHOLE HOUSE PackHtPump 12.000 SEER Ducts in Attic 4.2 SetBck Water No. Tank,. Ext. WATER HEATING SYSTEMS Heater in Ener.gy.Size Insul System.Name Distribution Type. Type.-. Sys Factor (gal) 'R -Val Std Gas 50 gal or- Less Standard StorGas 1. 0.53 50.0 12,`O AFUE WATER HEATER EQUIPMENT DETAIL /Rec Rated Stdby Tank Pilot System Name 1.System Type_ Eff Input Loss R -Val _Light • - - _..- - - - - - - - - - - - - - - - - - - - - - - - - - Y - - - - -.. - - - - - - - - - - - - Std G,as'•50 gal or Less DomesticHW 0.760 • 40000• 0.040 -,-'0.0 0 - SPECIAL FEATURES/REMARKS •. , POINT SYSTEM SUMMARY P -2R page 10 of 13. Project Name: BELNAP CONSTRUCTION 6Date: 11/2/1994 o. Documentation: MJT Construction.Services 6COMPLY 24 User 1160 BUILDING DATA ------------- Conditioned Floor Area 1400'sgft Number of Stories 1 Occupancy Type Single Fam Det SCORE CARD Measure Points 1. Roof Insulation 0.0283 (U -Value) 0. 2. Wall 'Insulation 0-0585 (U -Value.) -1 3. Raised Floor Insulation 0.0000 (U -Value) o 6 3a. Controlled Vent Crawlspace 0.0 (R -Value) o-> -1 a 4. Slab Edge Insulation 0.8164(f2 factor) -6 5.. Infiltration Standard 0 6. Glass Heat Loss 0.72 14.5% -1 Sum 1-6 -3 7. Fenestration.Heat Gain SC Orientation Area %,Glass Open Eff % SER North 44.0 3.1. x 0.77 _ ' 2.4 0.86 1 - East 117.3 8.4 x _ 0.77 _ 6.4 .0.86 -11 South 10.2. 0.7 x 0.77 = 0.6 0.86' 2 West 20.0 1.4 x 0.70 = 1.0 0.84 2 Skylight 12'.0 0,9 x 0.79 = 0.7 1.00 -4 8. Interior Thermal Mass 3.15'- 3 9. Exterior Wall Mass 0:00 0 Sum 7-9 -7 10. Heating System 0 Zonal Control: No 11. Cooling System 10 12. Water Heating = 0 Point Total: 0 HVAC ZONE HEATING & COOLING LOAD SUMMARY ---------------------------------------------- page 11 of 13, ---------------------------- Project Name:'BELNAP CONSTRUCTION 6Date: 11/2/1994 o Documentation: MJT Construction Services 6COMPLY 24 User 1160 HVAC ZONE DESCRIPTION, , HVAC Zone Name:' WHOLE HOUSE Heating System Name: �, Carrier SON0042 Cooling System Name: System Multiplier: - 1 Fan Schedule: Day Fans'STD Peak Load Method: NONCOINCIDENT .. Relative Humidity: 50 % COOLING SPACES IN THIS ZONE PEAK HEATING. PEAK ." SENSIBLE LATENT ----------------------- ---_ WHOLE HOUSE (Jan 12am) ------- 38054 --__ (Aug 2pm) 29464 861 -------- ----- TOTAL SPACE LOAD 38054 29464 861 Duct -Gains & Losses: 3805 2946 Return Air"Lighting Gain 0 TOTAL SYSTEM LOAD 41859 32410,, 861 SYSTEM OUTPUT AT DESIGN CONDITIONS 54935 • X32256 6763 NOTE: The TOTAL SYSTEM LOAD shown represents the minimum size equipment which will heat.or cool this zone during the design conditions indicated. These numbers include no safety factor, and the HVAC contractor'should oversize by a reasonable margin to account for variations in weather conditions and the pick-up capacity`required*to bring the zone to�'temper- ature as a result of a setback'thermostat. Those responsible for final equipment selection should note that Sensible and Latent Cooling Loads .are indicated to allow for accurate comparison with manufacturer' -s output data. RESIDENTIAL SPACE HEATING LOAD,SUMMARY --------------------------------------------------------------------------- page 12 of 13 Project Name:,BELNAP'CONSTRUCTION oDate:• 11/2/1994, Documentation:_MJT Construction Services --------------------------------------------------------------------------- 6COMPLY 24 User' 1160 Space Name: WHOLE HOUSE Design Indoor Dry Bulb Temperature: 70 F Design Outdoor Winter'Dry,Bulb Temperature: -- ` 29 F Design Temperature Difference: 41 F Conduction Area U -Value TD Btu/hr ----------------------- ------ - -----. - ---- . . ------ R=13 Wall w/1" EPS 1568.4 x 0.0585' x 41.0 = 3763 Double Clear' (NR Std) 187.6 x 0.7200 x 41.0 - 5536 Double Clear ( Res Std) 4.0 x` 0.7500 x 41 ..0 = 123 R=38 Roof(-R.38.2x14.16) 1388.0• x 0.0283 x 41.0 = 1613 Double Clear (Res Dflt) 12.0 x 0.8000 x 41.0 - 394 Slab on Grade Perim = 203.0 x 43 = 8729 Slab on Grade Perim = 176:0 -x 43 - 7568 Infiltration: 1.00 x,0.018 x 1400 sf x..10.0 ft x 1:00 AC x 41.0 = 10328 ,Ventilation: 1.080 x 1400 sf x -0.0 cfm / 333.0 x 41.0 = 0 TOTAL HOURLY HEAT LOSS FOR SPACE 38054 Heating AirFlow: 38054 Btu/hr. / A1.08 x •35 F Delta -T)0 = 1007 cfm t 1 r , RESIDENTIAL SPACE COOLING LOAD SUMMARY page 13 of.13 ----------------------------------------- --------------------------------- Project Name: BELNAP CONSTRUCTION 6Date: 11/2/1994 6 Documentation: MJT Construction Services 6COMPLY 24 User 1160 --------------------------------------------------------------------------- Space Name- WHOLE HOUSE Design Indoor Dry Bulb Temperature: 78 F Design Outdoor Summer°Dry Bulb Temperature: 112 F Design Temperature Difference': 34 F. Conduction Area U -Value ------- DETD ---- Btu/hr, ------ ----------------------- R-13 Wall w/1" EPS ------ -1568.4 x 0.0585 x 29-.6 = 2716 Double Clear (NR Std) 187.6 x 0.7200 x 34.0 = 4591 Double Clear (Res Std) 4:0 x 0.7500 x 34.0 = 102 R-38 Roof(R.38.2x14.16) 1388.0 x 0.0283 x 50.0 = 1967 Double Clear ( Res Dflt ) t 36.0 x 0.80 1 0 0 x 34.0 = 979 Infiltration: 1.00 x.0.018 x 1400 sf x 0.6 -ft x 1.00 AC x 34.0 - •8565 Ventilation: 1.080 x 1400 sf x 0.0 cfm %" 333.0 x 34.0 = 0 f Shaded Unshaded Solar Gain Orient. Area SGF - Area .SGF SC Double Clear ' ( NR Std) West A '3.2 x 15 +. 12.8 x 730 x 0.66 = 647 . Double Clear (Res Std) West A-' 4.0 x 15 + 0.0 x 730 x 0.66 = 40 Double Clear (NR Std) East A 0.0 x 15 + 117.3'x 730 x 0.66 = 5641 Double Clear (NR Std) South A 6.0 x 15 + 10.3 x 320 x 0.66 = 2.16. Double Clear (NR Std) North A 0.0 x 15 + 44.0 x 150 x 0.66 '_ 435 - Double Clear (Res Dflt) Skylight A 0.0 x 15 + 12.0,x1520 x 0.79-= 1445 Internal Gain Op Frac. Area Heat.Gain Conv.. Lighting 1.00 x 1400.0 x 0.200 '•x 3.413 - 956 Equipment .. 1 .00 -x- 1400.0 x 0.100 x3.413 - 478 Occupants 1.00 x 1400.0 x 225 /' 333 = 946 TOTAL HOURLY SENSIBLE HEAT GAIN FOR SPACE 29464 Latent Gain, Op Frac. Area Heat Gain Conv. Btu/hr ----------------------- Equipment --------------- 1.00 x --------- 1400.0 x 0.000 x ----- 3.413 ------ - 0 Occupants 1.00 x 1400.0 x 225 / 333 = 946. Infiltration: 1.00 x 0.018 x 1400 sf x 10.0 ft x 1.00 AC•x -0.3 - -78 Ventilation: 1.080 x 1400 sf x 0.0 cfm / 333.0 x -0.3 = -01 TOTAL HOURLY LATENT HEAT GAIN FOR,SPACE 861 Cooling AirFlow: 29464 Btu/hr / A1.08 x •23 F DeltaT)U = 1187 cfm w U