Loading...
04-3712 (SFD)i� P.O. Boz 1504 787495 CALLS-TAMPIC0. LA QUINTA CALIF RIMA 92253 BUILDING dt SAFETY DEPARTMENT (760) 777-7012 FAX (760).777-7011 INSPECTION RE UESTS 7 .. Q (760): 77-7153 BUILDING PERMIT Application. Number .04- 0_.7T2 Date 4/27/04 Property Address 53060.AVENIDA RUBIO;. APN: T74:=04`3-003=-22 -000000- Application description'., .;:.DWELLING.- SINGLE FAMILY DETACHED Property Zoning COVE RESTDENTIAL. . Application valuation.. : "�<. Y :U9732.3. °s Owner.y N ..>'Contractor,,. .. D6 H* DEVELOPMENT CORP " r `�•� DGH.DEVELO'PMENT CORPORATION ...,_ .... .,..:_.. ,. ..,... PO ,BOX 2 _..; :. -... P:.; 91. ... _.._ .... .. ... _9.`82 PALM" DESERT `' CA, 9.2261 _ ' PALM' DESERT t . _; :. = : `:. CA 9226-1 (7 60) 36'0:=,87'06 WCC..: STATE FUND, WC. -..-.11640909 ' `' 02/01/05 CS .`.. 480'1:2 �_:: ; .. ,... 09/30/05 CCC. .B, - - 0 C3�6C2. ----=--------=-=-=-=.----- Structure '.Information. --,.------'---------- -------- Construction°Type TYPE V-'NON,RATED Occupancy Type . . . DWELLG/LODGING/LONG`<=10 Flood Zone . . . . . . -NON=AO FLOOD.'ZONE Other struct 'info CODE EDITION, 2001..CBC #:BEDROOMS..-. 3.00. FIRE SPRINKLERS NO GARAGE. S.Q FTG, 440 40 PATIO' `SQa,FTG-.� •_76 ,0,0 NUMBER, OR. UMTS 1.00 F.IRST'FLOOR SQ:, .FTG. y 1533.00 ----- - - - - ---------- - - - - Permit Q 4 . sa -- -- -- -- -- - -------- --- - - - - -- BUILDING PERMITz� Addit.ional.desc Permit, Fee 63G.50 Plan .Cheek 'Fee 409.83 Is.su.e Date 3/03/04 Valuation 97323 Qty. Unit Charge Per Extension BASE FEE i.o,..<, 414.50 48.00 4.5000 THOU BLDG 50,001'100;000 216.00 Permit MECHANICAL - Additional desc . Permit Fee, .... 59.00 Plan.. Check 'Fee.. 14.75 ::Issue Date. _ Valuation 0 Qty Unit Charge. *Per Extension t •�{I N ! P.O. BOX 1504 VOICE (760) 777-7012 78-495 CALLS TAMPICO FAX (760) 777-7011 LA QUINTA, CALIFORNIA 92253 INSPECTIONS (760) 777-7153 BUILDING & SAFETY DEPARTMENT Application Number 01 3 7/z Date: 1l •�7� D� Applicant: Architect or Engineer. Applicant's Mailing Address: Architect or Engineers Address: Lic. No BUILDING PERMIT DECLARATIONS 1 Iwereby affirm under LICENSED CONTRACTOR'S DECLARATION DAY d perjury that I am licensed under Provisions Of ChaPer 9 (cornnenc np nth S@Ckn TOW) of Division 3 of the Business and Pmbuionets Code. and mylull brmx and atfecL Loerw Cls;c License No.- Dap, o._ rs U L a r Dab by slum under penalty d perjury that 1 am ONINER$tLDM DECLARATION oily or county Vial requires a permit b oorwlruct Sher. from the Cortracbi8' Stab License Law for the bbwiq ns•orh (Sec 70315. Business and Prolessiorwc Cod f: Any MpoMe. denworrstw or repair any slrudum p it b Its ketene•, 8150 requires Ma applicant ter the permit b ie a signed stalerr ole that Ins or she r fat he pmasuart b the proviciorws d the Contrackm* Stab Lker" Law P4 1er 9 (e0rrsnenCing with Section 7000) d Division 3 cite emlin"s and Prolessiorws Code) or that he rx she k exempt tnenekom and the basic for the alleged acerrmptiam. Any vk>f•ion of Section 7031.5 by any appieent ter a pannit subjects Aro Sppiant to a dwi penalty d not mere Man five hundredj. ) x U t ss owner d the property. a my errmThe with wages as their 5010 compehsaion, wT• do the work, and the strrclue k not ktended or ofm for 8810 (Sec 7044. Business end Prdessiorws (',oda The ConOrador8' Sthimself orate License Law does not apply b an owner d property who guilds a improves Vwereorn, and wwfmo does the wwork sold orae or VroLo Itis or her own employees, Provided that the iWromnerft are not kw -1 1P or a fared for sale. K, howweyw, the built ft or inprovrrnent k (, !. as owner d the l� d �r�4 Vr Oww-b alder w� have the burden d proviq that he or she dd not build err knprove for the purpose d sale.} Stab License not property am *N*mv* aontracewg with licensed eontracbm b coralruct"pojed (Sec 7044. Business and Piolsssions Code: The Contr•atas' apply ben owner of papetty who builds or improves thaSon, and who contracts lex the projects with • contractor(s) kwised pursuant b the Cantraclow State License Lew.). () I am exempt under Sec . SA P.C. for this reason Date" Owner 1 hereby affirm under penalty d Perjury one d the WORKERS, C0MPENSATION DECLARATION _ I have and will maktakn a culikMe d consent 10 ter rrorkeW O the work ter which this per.. k ksued m p'ovid0d for by Section 3700 of the Labor Code, br the peAomanoe _ 1 have and will maintain wonkers' compensation 1naxwxx4 ss by Section 3700 of the Labor Code. for the perbrmmure d the work br whish this permit is ed_My a' comp cation kwsuraioe canier • Cartier I'Mility that• in the ppb 1� Of to work lior va pew it issued, Ino employ any person in any narner so as to become subject b the workers' 85 on lovers of C80rma p iprOa, and vFsions. agree Mat V 1 should become subject b brihoft comrply with those the workers' compensation provisions Of Section 3700 of the Labor Code, l shah WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SFWLL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CML FINES UP TO ONE ItUNDRED THOUSAND DOLLARS ($100.000). IN ADDITION TO THE COST OF COMPENSATION. DAMAGES AS PROVIDED FOR IN SECTION 3708 OF THE LABOR CODE- MEREST. AND ATTORNEY'S FEES. . I henry affirm underCONSTRUCTION LENDING AGENCY DewdtY d Pe)u!Y that Mwero k a construction landing agencyfor to Pwkmw" at hi the work for wdh this permitk ksued (Sec. 3097. Civ. C.). Lenderc Name ��� Lenders Address IMPORTANT Application is hereby m fft b the Director of APPLICANT ACKNOWLEDGEMENT SWISmg wdrti end Safety for a Permit subject b the eorons and restrictions set forth on this appicaioa 1. Each person upon whose behalf Vmk Issued as a result d Mira a k made. each person at whose request and for whose benefit work k peAortne0 under a pursuant b any permit dficeM Std ppication, Awe owner. and the appicaml, each agrees b. and stall. defend. indemnify and hold harmless the City d La Cults, its Z Any oaf N" a d as a resulta for ad or n fission related b tlm wpk being performed under or following Issuance d the poi n cessation d work for 180 da will becomes rrrr and void if work knot commenced within 150 d>tys k0m date d issuance d such Permit or 1 certify that I have read this >z N b ' oonrtify that I and application and state that the above kooration k correct. I agree b comply with all city and county ordirwms and stab laws b (hereby MAhorin representatives d tis caxdy b enter upon the above-mentioned property for Inspection purposes. rolrinq brddinp Date Signature (Applicant or Page 2 Appli,catibn Number 04-00003712 Date 4/27/04 Qty Uriit Charge. Per. Extension BASE :, FEE. 15.00 1. 00 . 9.0.000, EA MECH-FURNACE '<=100K , 9.00 ; 1..00. 9.0000 EA MECH B/C�<=3HP/100K.BTU 9.00 3.00 6.: 50.00. EA ME CH : VENT FAN 19.50 1.00. 6.50`00 .EA ME0H4:_EXHAUST HOOD 6.50 Permit PLUMBING Additional ,'desc-',. -AtPetmit Fee .123.00 Plan Check Fee*-. 30.75 Issue% Date Valuation . . . . 0 Qty Unit Charge Per Extension BASE FEE, : = 15.00 9.00 6'. 000.0:- EA PLB' FIXTURE 54.00 1.00 15.0000.- EA PLB BUILD I NG'SEW ER 15.00 1.00'- 7:5,000 EA PLB:WATER-HEATER/.VENT 7.50 1.00 3.0;0.0'0 EA ' PLB"WATER•. INST%ALT/REP 3.00. 1.00 9.0000 EA_'. -,PLB'.LAWN SPRINKLE -R SYSTEM 9.00 6.00 .7500 EP; PLB GAS PIPE''.>=5. 4.50 1-00 15.0000: EA PLB GAS. 'METER'' 15.00 Permit . . . . . ELEC-NEW= RESIDENTIAL' Additional desc Permit Fee: 92;46 Plan Check .Fee 23.12 Issue.Date . . . Valuation . . . 0 Qty Unit Charge' Per Extension BASE FEE 15.00 1533.00 .0350 ELEC`NEW RES - 1 OR 2 FAMILY 53.66 440.00 020'0' ELEC GARP;GE OR,NON-RESIDENTIAL 8..80 1.00 ,15.0000 EA-:*;''ELEC TEMPORARY.'POWER`POLE 15.00 Permit . . . . . . GRADING:,PERMIT Additional desc Permit Fee i5.00 Plan Check Fee .00 Issue Date . . . . _ Valuation 0 Qty Unit Charge Per Extension BASE 'FEE . 15.00 Special Notes and Comments;: SFD - 1533- S.F. PERMIT DOES NOT INCLUDE ,* Page 3 ' Application.Number .. •h 04-00003712 Date 4/27/04 . ' — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — ----------------------------- — —l----- — --- — ------------------------------- Special Special_ Notes andLComments_ POOL/SPA, BLOCK `WALLS.,: OR'�DRIVEWAY APPROACH. - --------------- — — -• . — — — — — — — ------------- '.. Other Fees k --------------------------------------- . .. ART IN PUBLIC PLACES=RES .00 ... DIF. COMMUNITY CENTERS-RES 97.00 = bIF CITIC CENTER. = RES 366.00 ENERGY REVI'EW FEE: 40.98 DIF". FIRE PROTECTION-RES 97.00 GRADING-:PLAN CHECK FEE .00 DIF LIBRARIES'- RES 225.00 DIF PARK MAINT FAC'- RES 5.00 DIF:-PARKS/REC RES 502.00 - a, COVE 'PRECISE a, PLAN�'FEE 100.-00 STRONG 'MOTION• (SM11) - RES 9.73 DIF.,.STREET MA-INT FAC.=RES 15.00 ....DIP-"TRANS'P.ORTATION - RES 1098.00 Fee summary Charged Paid. Credited Due Permit.Fee Total 919-..96 00 .00 919.96 Plan Check Total 478`:45 250.00 .00 228.45 Other Fee;'Total 2555.71 ..00 .,00 2555.71 Grand, Total 3954:12 250`..00 .00 3704:12 tis Address Owner V. Mailing Address Address I k--a'01,� Gity I , Zips 4 P.O. BOX 1504 78-495 CALLE TAMPICO i LA QUINTA, CALIFORNIA 92253 Nkowl �-d�( APPLICATION ONLY oma!• 3762. BUILDING: TYPE"CONST. i-' OCC. GRP. A.P. Number — w Tel. 4zl �2 (� LIC 1-7 �" tD — Legal Description Project Description 1 f Tel.. State Lic. I City & Classif. �-� / Lic. # Arch., Engr., ! Designer Address Tel. City Zip State Lic. # 7J :L'ICENSEO CONTRACTOR'S DECLARATION I herebyy afli hat I am;license er provisions of Chapter 9 (commencing with Section eTODO)ffec of.Di qn� of t1ie.Busin" s d Professions Code, and my license is in full force and effect. a % opt 0, : _.. v . OWNER -BUILDER DECLARATION I hereby affirm that -l.am,exempt from the Contractor's License Law for the following reason: (Sec. 7031.5,Business and Professions Code: Any city or county which requires a permit to construct, alter, Improve, demolish, or repair any structure, prior to its issuance also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor's License Law, Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, or that. he is exempt therefrom, and the basis for thealleged exemption. Any violation of Section 7031.5 by 'any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500). I: I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. (Sec. 7044, Buisness and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he did not build or improve for the purpose of sale.) I I I, as owner of the property, am exclusively contracting with licensed contractors to con- struct the proiact. (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who contracts for such projects with a contractor(s) licensed pursuant to the Contractor's License Law.) 1! 1 am exempt under Sec. B. & P.C. for this reason Date Owner WORKERS' COMPENSATION DECLARATION I hereby affirm that I have a certificate of consent to self -insure, or a certificate of Worker's Compensation Insurance, or a certified copy thereof. (Sec. 3800, Labor Code.) Policy Nd. Company Cl Copy is filed with the city. ❑ Certified copy is hereby furnished. CERTIFICATE OF EXEMPTION FROM WORKERS' COMPENSATION INSURANCE (This section need not be completed if the permit is for one hundred dollars ($100) valuation Or less.) I certify that in the performance of the work for which this permit is issued, 1 shall not employ any person in any manner so as to become subject to the Workers' Compensation Laws of California. Dale Owner NOTICE TO APPLICANT: It, atter making this Certificate of Exemption you should become subject to the Workers' Compensation provisions of the Labor Code, you must forthwith comply with such provisions or this permit shall be deemed revoked. CONSTRUCTION LENDING AGENCY 1 hereby affirm that there is a construction lending agency for the performance of the work for which this permit is issued. (Sec. 3097, Civil Code.) Lender's Name Lender's Address This is a building permit when properly filled out, signed and validated, and is subject to expiration if work thereunder is suspended for 180 days. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives -of this city to enter the above- mentioned property for inspection purposes. Signature of a0plicant Date Mailing Address City, State, Zip Sq. Ft.No. No. Dw. Size !.�'3 3 Stories Units New)( Add ❑ Alter ❑ Repair ❑ Demolition ❑ 17 32 3 ✓atus►Tcma PERMIT Plan Chk. Dep Plan Chk. Bal. Const. Mech. Electrical Plumbing S.M.I. Grading Driveway Enc. Infrastructure AL 7. ter• - I _ I ZONE: BY: Minimum Setback Distances: Front Setback from Center Line Rear Setback from Rear Prop. Line Side Street Setback from Center Line Side Setback from Property Line FINAL DATE INSPECTOR Issued by: Date Permit Validated by: Validation: a WHITE = BUILDING DEPARTMENT YELLOW = APPLICANT PINK = FINANCE Date 3/16/04 No. 25695 Owner DISH Development Corp. CERTIFICATE OF COMPLIANCE Desert Sands Unfed School District 47950 Dune,Palms Road La'Qu,inta CX 92253 ;(760).;771-8515 APN # 4G'_,S F, DSc 0 z o Q BERMUDA DUNES (n RANCHO MIRAGE INDIAN WELLS �. PALM DESERT ,y t� LA QUINTA INDIO Q L� 0 774-043-003 Address P.O.Box 2982 Jurisdiction La Quinta City Palm Desert Zip 92261 Permit # Tract # Study Area Type Single Family Residence No: of Units 1 Lot # No. Street 3':f=. Lot # No. Street S.F. Unit 1 53060 Avenida Rubio 1533 .,. Unit 6 Unit 2 Unit 7 Unit 3 Unit8.: Unit 4 Unit 9 Unit 5 Unit 10. , . Comments Certs #25690 through 25697 used forCC#88079,in the amount of $26;248.00. Overpayment in $3.04"paid in,cash.REP 2lNT ISSUED 4/28/04 AS ORIGINAL.-MISPLACED/LOST. At the present time, the Desert Sands Unified School District does pot collect fees on garages/carports, covered patios/walkways, residential additions under 500 square feet, detached accessory structures (spaces that do not.contain facilities for living, sleeping, cooking, eating or sanitation) or replacement mobile homes. It has been determined that the above-named owner is exempt from paying school fees at this time due to the following'mason: EXEMPTION.'NOT APPLICABLE This certifies that school facility fees. imposed pursuant to Education Code Section 17620 and Government Code 65995 Et Seq. in the amount of $2.14 X 1,533 S.F. 0:e--,$3,280:62 have been paid for the property listed above and that building permits and/or Certificates of Occupancy for this square footage 6.'this proposed project may now be issued. Fees Paid By. CC/Palm .Desert Nat'l, Bank - David Heusinkveld Check No. 080079 Name on the,check Telephone 760/360-8706 Funding Residential By Dr. Doris Wilson Superintendent Fee collected /exempted b aron McGilvrey Payment Recd 1$0.00 $3'1280.62 Over/Under Signature NOTICE: Pursuant to Government Code Section 66020(d)(1), this will serve to notify you that the 90 -day approval period in which you may protest the fees or other payment identified above will begin to run from the date on which the building orinstallation permit for this project is issued, or from the date on which those amounts are paid to the District(s) or to another -public entity authorized, to collect them on the District('s)'behalf, whichever is earlier. NOTICE: This Docuirient'NOT VALID'if Duplicated Embossed Original - Building Department/Applicant Copy - Applicant/Receipt Copy - Accounting ' -�LiCertificate of Occupanc r • _ .r t ,- %d G�0 Buildin "&.,..Safbty, De artment r I -,This, Certificate•isrissued, pursuant: to'the req uirements of Section 109,'of'the California Building Code, ~certifying Chat, ` at the: tune of issuance,' this structure was' -in compliance with the provisions of the Building,,Code{ and the various ordinances of the tiCity regulating .building con st_ruction,and_/or use. Y- ' BUILDING ADDRESS: 6060 AVENIDA:RUBIO Use classificat-ion:•SFD _ - _ Building Permit No.: 04-3866 - Occupancy.Group: R3 Type, of Construction: VN ' Land Use Zone: RC Owner of Building: DGH '� "��; Address:'PO BOX 2982 City, ST; ZIP: PALM DESERT CA 92261' - By: KIRK KIRKLAND Date: 9-20-04 - r ra -Building..Official _t POST IN A CONSPICUOUS PLACE ' • _ .r t a I I . TITLE.24 REPORT I F Title 24 Report for: " DGH CONSTRUCTION " Plan 1533 Sq.Ft. Four Cardinal Orientations La Quinta, CA 92253 53-00 j-vG. kuloi'o Project Designer GLS GROUP 74-854 VELIE WAY, Suite #5 Palm Desert, CA 92211 760-340 3528 Report:Prepared By: S L.O GLS Group 74-854 Velie Way, Suite 5 Palm Desert, CA 9226:0 (760) 340-3528 Job Number: LQ -04-T17 Date: 2/4/2004 :6 t.Y OF LA QUINTA BUILDING & SAFETY DEPT. APPROVED FOR CONSTRUCTION DATE'y-O BY ffr ^ o�O&S The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2001 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC (415) 883-5900. EnergyPro 3.1 By EnergySoft Job Number: LQ - 04 - T17 User Number 5553 i TABLE OF CONTENTS Cover Page Table of Contents Form CF -1 R Certificate of Compliance Form MF -1 R Mandatory. Measures Checklist Form C -2R Computer Method Summary Form ENV -3 Proposed Construction Assembly HVAC System Heating and Cooling Loads Summary 1 2 3 6 8 12 13 EnergyPro 3.1 By EnergySoft Job Number: LQ - 04 - T17 User Number. 5553 Certificate -of -Coftliance. Resiftntial(Part 1 CF -1 R " DGH CONSTRUCTION" Plan -1533 Sq Ft 2/4/2004 Project Title R-38 Roof (R.38.2(4.24) Date Four Cardinal Orientations.. La Quinta Slab On Grade Na Project Address Covered Slab WR -0:6 Perimeter Insulation Slab On Grade Building Permit # GLS Group (760) 340-3528 R-19 Wali (W.19.24.16) Wood Documentation Author =.. Telephone Solid Wood Door Plan check / Date Computer Performance 15 R-19 Wall (W.19.2x6.16) 1/2+5/8 GYP Field Check/ Date Compliance Method (Package or Computerj Climate Zone Enforcement Agency Use Only GENERAL•INFORMATION Right 56.0 Total Conditioned Floor Area: 1;533 ft2 Average Ceiling Height: 9.7 ft Total Conditioned Slab Area: 1 .533 ft2 Rear Building Type: 0.65 0.40 Bug ScreenX❑ (check one or more) ❑ Q ® Single Family Detached. ❑ Addition ❑ Single Family Attached ❑ Existing.Building ❑ Multi -Family . ❑ Emstinq Plus Addition Front Orientation: All Four Orientations Floor Construction Type: FX] Slab Floor . Number of Dwelling Units; 1.00 Number of Stories: 1 0 Raised Floor tiUILUINU SMELL IN5ULATION Component Type Frame. Type Const.. . Assembly U -Value Location/Comments (attic; -.garage, typical, etc.) R-38 Roof (R.38.2(4.24) Wood 0.024 Exterior Roof. . Slab On Grade Na 0.756 Covered Slab WR -0:6 Perimeter Insulation Slab On Grade Na 0.756 Exposed Slab w/R-0.0 Perimeter Insulation R-19 Wali (W.19.24.16) Wood 0.065 Exterior Wall Solid Wood Door None 0.387 Exterior Door. R-19 Wall (W.19.2x6.16) 1/2+5/8 GYP Wood 0.060 Exterior Wall t tNt, I KA I IUN Shadin De vices Type :Orientation Area Fenestration Exteriorj�Yes/ verhang Side Fins SF U -Factor • SO GC •Shadin No Yes / No Front 29.0 . 0.65 0.40 Bug Screen X❑ ❑ FRI❑ Left 38.0 0.65 0:40 Bug Screen X❑ ❑ ❑ x❑ Right 56.0 0.65 0.40 Bug SweenX❑ ❑ ❑ Rear 40.0 0.65 0.40 Bug ScreenX❑ ❑ ❑ Q ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ 1:1 El n ❑❑- ❑❑ 1-1 EI ❑❑ 1:1 El ❑❑ ❑❑ El El Run Initiation Time: 02/04/04 08:55:51 Run Codec •1075913761 - EnergyPro 3.1 By EnerqySoft User humbec5553 Job Number LQ - 04 - T17 Pa e:3 of 13 Certificate_ of Compliance: Residential _ (Part 2 of 2) CFA R ' DGH.CONSTRUCTION " Oiari 15333S .Ft: 2/4/2004 Project Title Date N HVAC SYSTEMS Note: inputtHydronic or Combined'Hydronic data under Water Heating Systems, except Design Heating Load. Distribution Heating Equipment Minimum Type and . Duct or Type (furnace, heat Efficiency: Location Piping Thermostat. Location/ pump, etc.) (AFUE%HSPF){ducts; attic, etc.) . R -Value , Type Comments. Central Fumace 80%AFUE Ducts in Attic 42 Setback HVAC Split System Gas/ ler Cooling Equipment Minimum Duct Type (air conditioner, Efficiency Location Duct Thermostat Location/ heat pump, evap. cooling) (SEER) (attic; etc.) R -Value Type . - . Comments Split Air Conditioner WATER HEATING SYSTEMS . Rated 1 Tank Energy Facts 1 External Water Heater Water Heater Distribution # in Input Cap. or RecoveryStandbyy Tank Insul. System Name. Type Type Syst. Btu/hr (gal) Efficiency Loss (%) R -Value A.O Smith FSG40-"2 Small Gas Standard 1_ 32 000 _40 0-56 n/a 12 1 For small gas storage (rated inputs of less than or equal to 75,000 Btu/hr), electric resistance and heat pump v.rater heaters, list energy factor. For large gas storage water heaters (rated input of greater than 75,000 Btu/hr), list Rated Input, Recovery Efficiency and Standby Loss. For instantaneous gas water heaters, list Rated Input and Recovery Efficiency. REMARKS vveverur�eaa.G v e rs e ceveeav e , This certificate;of compliance lists the building features and performance specifications needed to comply with Title 24, Parts 1 and 6 of the California Code of Regulations, anis the administrative regulations to implerrienf them. This certificate has been signed by the individual with overall design responsibility. The undersigned recognize that compliance using duct sealing and TXV's requires installer testing and certification and field verification by an approved HERS rater. Designer or Owner (per Business & Professions Code Documentation Author Name: Name: S L O Title/Firm: GLS GROUP Title/Firm: GLS Group Address: 74-854 VELIE WAY. Suite #5 Address: 74854 VelirWay. Suite 5 PalriV%ert. CA 92211 m Des rt A 92260 Teleph 7 3528 ATelepho :7s t3 Lic. # D p4 (signature) (date).' (signature) . (date) Enforcement Agency Name: Title/Firm: Address: Telephone: Certificate of Compliance: Residential.._ .: _ .(Addendum) . CF -1 R " DGH CONSTRUCTION " Plan 1533 Sq Ft 2/4/2004 Project Title Date Special Features and Modeling Assumptions The local enforcement agency should pay special attention to the items specified in this checklist.. These items require special written justification and documentation, and special verification to be used with the performance approach. The local enforcement agency determines the adequacy of the justification, and may reject.. building or design that otherwise complies __ _ ......._ .... ,, ....., �,,...o. �,.�..... a..v,..a..0 UVUU.n1Cnaauvn mY...uMU. Plan J Field The DHW System "A.O.Smith FSG -40-222" Energy Factor = 0.560. An EF below 0.58 requires an R-12 External Blanket. The HVAC System "HVAC Split System Gas/Elec" includes credit for a Radiant Barrier installed per Section 8.13 of the Residential Man HIGH MASS Design(see C -2R) - Verify Thermal Mass: 839 sqft Covered' Slab Floor, 3.50" thick at Whole House HIGH MASS Design(see C -2R) - Verify Thermal Mass:. 694 sgft'Exposed Slab Floor, 3.50" thick at Whole House HERS Required Verification These features must be confirmed and/or tested bar a certified HERS rater under irlthe supervision of a CEC approved HERS nrnvnr Tk- YCOC r ** ...... A......:....� ate_ -. • ---- - --- ------ ---- ••-------..._•.• ••• •• • • •••. ..•..... u.......oy..v�aw .�uny v1 uiCSC nlga5urt75 on a form G1__UrC Plan Field EnergyPro 3.1 By EnergySoft User Number: 5553 Job Number: LQ - 04 - T17 Page:5 of 13 r Mandatory Measures.,Checklist:Residential (Page 1 of 2)MF-1 R NOTE: Lownse residential buildings'subject tothe Standards must contain these measures regardless oft uil compliance approach used. Rems'marked.whh an max.. . asterisk (*)may be superseded by more stringent compliance requirements listed on the Certificate'of Compliance. When this checklist is incorporated into the permit documents, the•fe'atures noted sh6dbe considered. by all parties as minimum component performance specifications for the mandatory measures whether they ere.shown elsewhere in the documents or on this checklist oniv. DESCRIPTION Instructions:,Check or initial applicable boxes or enter WA if not applicable. DESIGNER. ENFORCEMENT Building Envelope Measures �'§150(a): Minimum -R-19 ceiling insulation.. §150(b): Loose fill insulation manufacturer's labeled R -Value. a'§150(c):' Minimum R-13 wall insulation in wood framed walls or equivalent U -value in metal frame walls (does not apply to exterior mass walls). ' 0 `§150(d): Minimum R-13 raised floor insulation in framed floors or equivalent. §1500): Slab edge insulation - water•absorption rate no greater than 0.30k; water vapor transmission rate no . ❑ greater than 2.0 permfinch. EXJ §118: Insulation specified or installed meets insulation quality standards. Indicate type and form. §116-17: Fenestration Products, Exterior Doors and Infiltration/Exfiltration Controls 1. Doorsand windows between conditioned and unconditioned spaces designed to limit air leakage. 2. Fenestration products (except field fabricated) have label with certified U -Factor, certified Solar Heat Gain Coefficient (SHGC), and infiltration certification. 3. Exterior doors and windows weatherstripped; all joints and penetrations caulked and sealed. §150(g): Vapor barriers mandatory in Climate Zones 14 and 16 only. § 150(f): Special infiftration barrier installed to comply with Section 151 meets Commission quality standards: ® §150(e): Installation of Fireplaces, Decorative Gas Appliances and Gas Logs. 1. Masonry and factory built fireplaces have:: a. Closeable metal or glass door b. Outside air intake with damper and control c. Flue damper and control 2. No continuous burning gas pilots allowed. ,c Space Conditioning, Water Heating.and-Plumbing .System Measures §110-13: HVAC equipment, water heaters, showerheads and faucets certified,by the Commission. ® § 150(h): Heating and/or cooling loads calculated in accordance with ASHRAE, SMACNA or ACCA. a§150 ow Setback thermostat on all,applicable heating'and/or cooling systems. § 1506): Pipe and Tank Insulation 1. S4orage gas water heaters rated with an'Energy Factor less than 0.58.must be externally wrapped with insulation having an installed thermal resistance of R-12 or greater. . 2. First 5 feet of pipes closest to•water heater tank, non -recirculating systems, insulated (R-4 or greater) 3. Back-up tanks for solar system, unfired storage tanks, or other indirect hot water tanks have R-.12 external insulation or R-16 combined intemallextemal insulation. 4. All buried or exposed piping insulated in recirculating sections of hot water systems. 5. Cooling system piping below 55 degrees F. insulated. 6. Piping insulating between heating source and indirect hot water tank. ' EnergyPro 3.1 By EnergySoft User Number: 5553 Job' Number: LQ - 04 - T17 Page:6 of 13 NOTE: Lowrise residential buildings subject .to'the Standards'must contain these measures regardless of the compliance approach used. Items marked with an asterisk,(*) may be superseded by more stringent compliance requirementslisted on the Certificate of Compliance When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown "elsewhere in the documents or on this checklist only. DESCRIPTION . Instructions: Check or initial applicable boxes or enter N/A if not applicable. DESIGNER ENFORCEMENT Space Conditioning, Water Heating and Plumbing System Measures: (continued) FX -]'§150(m): Ducts and Fans 1. All ducts and plenums installed, sealed and insulated to meet the requirements of the 1998 CMC Sections 601, 603, 604 and Standard 6-3; ducts insulated to a minimum installed level'of RA.2 or enclosed entirely in. conditioned space. Openings shall be sealed with mastic, tape, aerosol sealant, or other duct -closure system that meets the applicable requirements of UL181, UL181A; or UL181B. If mastic or tape is used to seal openings greater than 1/4 inch, the combination of mastic and either mesh or tape shall be used. Building cavities shall not be used for conveying conditioned air. Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such tape is used in combination with mastic and drawbands. 2. Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the -cross-sectional area of the ducts.. 3. Joints and seams of duct systems'and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such a tape is used in combination with mastic and drawbands. 4. Exhaust fan systems have back draft or automatic dampers. 5. Gravity ventilation systems serving conditioned space have eitherautorriatic or readily accessible, manually operated dampers. 6. Protection of Insulation. Insulation shall be protected from damage, including thatdue to sunlight, moisture, equipment maintenance, and wind but not limited to the following: Insulation exposed to weather shall be suitable for outdoor service e.g., protected by aluminum, sheet metal, painted canvas, or plastic cover. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that can causedegradation of the material. ❑§114: Pool and Spa Heating Systems and Equipment 1. Certified with 78% thermal efficiency, on-off switch, weatherproof operating instructions, no electric resistance heating, and no pilot. 2. System is installed with at least 36" of pipe between filter and heater for, future solar, coverfor outdoor pools or spas. a. At least 36" of pipe between fitter and heater for future solar.heating. b. Cover for outdoor pools or outdoor spas. 3. Pool system has directional inlets, and a circulation pump time switch. §115: Gas fired central furnaces, pool heaters, spa. heaters or household cooking appliances have no - ... continuously burning pilot light (Exception: Non -electrical cooking appliances with pilot < 150 Btu/hr) ❑ §118 (f): Cool Roof material meet specified criteria Lighting Measures ® §150(k)1: Luminaires for general lighting in kitchens shall have'lamps with an efficacy 40 lumenshvatt or greater for general lighting in kitchens: This general lighting shall be controlled by a switch on a readily accessible lighting control panel at an entrance to the Idtchen. RI §150(k)2: Rooms with a shower or bathtub must have either at least one luminaire with lamps with an efficacy of 40 lumens/vratt or greater switched.at• the entrance to the room or one of the alternative to this requirement allowed in Section, 150(k)2.; and recessed ceiling fixtures are IC (insulation cover) approved. 3.1 By EnergySoft User Number: 5553 Job Number: LQ - 04 -_T77 Page:? of 13 Computer Method Summary - . (Part 1 -of 3)- C -2R " DGH CONSTRUCTION "-Plan 1533 Sq:Ft. 2/4/2004 Project Title Date Four Cardinal Orientations. La Quinta Project Address Building Permit # GLS Group( -760) 340-3528 Plan check/Date Documentation Author Telephone Computer Performance 15 'L Feld Check/Date Compliance Method (Package or Computer) Cimate Zone ..,,.: Source Energy. Standard Use (kBtu/sf-yr) Design Space Heating 3.88 Facing North _Margin Thermostat Facing East . MaPgin Zone Name Facing South Margin Zone Type Type Facing West Margin 4.08 -0.20 4.20 -0.31 4.15 -0.27 3.94 -0.06 Space Cooling 41.64 39.41 2:22 38.50 3.14 39.62 2.12 38.80 2.84 Domestic Hot Water. 15.53 14.49 1.04 14.49 1.04 14.49 1.04 14.49 1.04 57.98 3.07 57.1'8 3.87 58..16 2.89 57.22 3.82 Totals 61.05 Total Conditioned Floor Area: Building Type: Building Front Orientation: Number of Dwelling Units: Number of Stories: 1;533 ft2 in all orientations. Single Fam Detached Floor Construction Type: All Four Orientations . Total Fenestration Area: 1.00 Total Conditioned Volume: 1 Total Conditioned Slab Area: ❑ Raised Floor ❑X Slab Floor 10.6%. 14,809 ft 3 1,533 ft2 BUILDING ZONE INFORMATION # of Thermostat Vent Zone Name Floor Area Volume Units Zone Type Type Hgt. Area HVAC . System ran/Flec I Sa1480 1_pp_ condai�e Setback _2 n(a OPAQUE SURFACES Solar Act. Gains Type Area. U -Val. Aam. Tilt Y / N Form 3 Reference / Comments ❑ ❑ ❑ ❑ ❑❑ Run i fo Time: 02/04/04 08:66:61 Run Code: 1076913751 3.1 By EnergySoft User Number. 5553 lQ - 04 = T17 Page:8 of 13 Com outer -Method Surhmary (Part 2 00) 'C -2R " DGH CONSTRUCTION "-Plan 1533 Sq.Ft. 2/4/2004 Project Title Date -FENESTRATION SURFACES Glazing Type Location/ . # Type Area . Factor SHGC Aim'. Tilt Comments L Window Front (North) 24 0 0 650. 040 n.: _ad DEFALII T DBI 'ANF Whnl He Hca 2 Window Front (North) 5.0 0.650 0.40 0 90 DEFAULT DBL PANE.. - Whole House 5 Window Left (East) 16.0 ' 0.650 0.40 1 90 90 DEFAULT'DBL PANE Whole House 4 Window Left '(East) 16.0 0.650 .0.40 90 90 ,DEFAULT DBL PANE 'Whole House 5 Window Left (East) 6.0 0.650 0.40., 90 g0 DEFAULT DBL PANE Whole House 6 Window Right West) 40.0' .0650 0.40 270 90 DEFAULT DBL PANE Whole House L Window Rear (South) 40.0 0,650 0-40 180 _$Q:DFFAULT DBL PANE Whole House 8 Window Right (West) 16.0 0:650 0.40'- 270 90 DEFAULT DBL PANE Whole House INTERIOR AND EXTERIOR SHADING Window Overhang Left Fin Right Fin # Exterior Shade.TVpe SHGC Hgt. Wd. Len. Hgt. LExt. ''RExt. Dist. Len. _ Hgt Dist Len Hgt 1 Bug Screen 0.76 4.0 6.0.. .,2.0 0.1 2.0 2.0 2 Bug Screen 0.76 '5.0 110 12.5 0.1 . 0.0 0.0 3 Bug Screen .0.76 .4.0 4.0 " 2.0 0.1 2.0 2.0 4 Bug Screen 0.76 4.0 4.0 2.0. 0.1. 2.0 2.0 5 Bug Screen 0.76 2.0. 3.0 2.0. 0.1 2.0. 2.0 .. . 6 Bug Screen 0.76 6.7 6. 0, 2.0.... b-1 . 2.0 2.0 7 Bug Screen ..0.76 6.7. 6.0 . �.2.0 ... 0..1 2:0 2.0 :... 8 Bug Screen 0.76 4.0 , 4.0 2.0 " ' 0.1 2.0 2.0 3.1 By Energysoft User Number.. 5553 Run Code: `i Number: LQ - 04 r17 of 13 Computer Meth®d,as um maiy (Part _3 of. 3) _C. -2.R " DGH CONSTRUCTION -Plan 1533..Sq.Ft. 2/4/2004 Project Title • Date THERMAL MASS FOR HIGH`MASS,DESIGN Area. Thick.4Heat*. Inside Location Type (sf) ,(in) Cap:;.Cond. ,Form 3 Reference R=Val. Comments Concrete. Hea0yeight P-49 3F;0:' �A .- O 0: n/a s. _9 :: Wh6a Heusp / Slab en Trade Concrete, Heawweight 694 3_50 28 0 n/a 0 Whole House / Slab on Grade PERIMETER LOSSES F2 Insulation actor R -Val. De Slab Perimeter 104 076 Slab Perimeter M 0.76 0-0 HVAC SYSTEMS tion/'Comments Heating Equipment Minimum Distribution Type Type (furnace, heat Efficiencyy. and.Location Duct Thermostat. Location / pump, etc.) (AFUE/HSPFXdicts/attic, etc.) 'R -Value Type Comments Central Furnace 80%AFUE Ducts in Attic 4.2 Setback HVAC Split ystem Gas/Flee Hydronic Piping pipe Pipe Insul. System Name Length Diameter 'Thick. Cooling Equipment MinimumDuct Type (air conditioner, Efficiency Location Duct Thermostat Location % heat pump, evap. cooling) (SEER) (attic, etc) R -Value Type Comments Split Air Conditioner 12 0 SFFR Ducts in Attic _ 4.2 Setback HVAC Snlit WATER HEATING SYSTEMSRated/ Tank Energy Facts Tank Insul. Water Heater Water Heater Distribution . # in Input Cap. or Recovery Standby 1 R -Value System Name Type Type. Syst. _-(Btu/hr) (gal) Efficiency Loss (%) Ext. A.O.Smith FSG 40-222 Small Gas Standard 1 32,000 40 0.56 1 For small gas storage (rated input.— 75000 Btu/hr), electric' resistance and heat pump water heaters,.list energy factor. For large gas storage water, heaters (rated input > 750001:Btu/hr), list Rated Input, Recovery Efficiency and Standby Loss.. . For instantaneous gas water heaters, list Rated Input, "and+RecoveryEfficiency.' " REMARKS Run 'Initiation Time: 02/04/64 08:66:61 Run Code: 1076913761 EnergyPro 3.1 By Ener Soft User Number. 5553 Job Number: LQ - 04 - T17. Pa e:10 of 13 Computer Method Summary per_ :::(Addendum) C -2R " DGH CONSTRUCTION " Plan 1533 Sq Ft 2/4/2004 Project Title Date Special Features and Modeling Assumptions The local enforcement agency should pay special attention to the items specified in this checklist .•These items require special written justification and documentation, and special verification to be used with the performance approach. The local, enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise. comp lies based on the adequacy of the special justification and documentation, submitted. Plan Field The DHW System "A.O.Smfth FSG -40-222". Energy Factor = 0.560. An EF below 0.58 requires an R-12 Extdmai Blanket. The HVAC System "HVAC Split System Gas/Elec" includes credit for a Radiant Barrier installed per Section 8.13 of the Residential Mail al. HIGH MASS Design(see C -2R) - Verify Thermal Mass: 839 sqft Covered Slab Floor, 3.50" thick at Whole House HIGH MASS Design(see C -2R) - Verify Thermal Mass: 694 sqft Exposed Slab Floor, 3.50" thick at Whole House HERS Required Verification These features must be confirmed and/or tested by a certified HERS rater under the supervision of a CEC approved HERS provider. The HERS rater must document the field verification and diagnostic testing of these measures on a form CF -6R Plan Field EnergyPro 3.1 By EnergySott User Number: 5553 Job Number: LQ - 04 - T17 Page: 11 of 13 OPOS.ED CONSTRUCTION 4SS:EMBLY ENI t PROJECT NAME DATE " DGH CONSTRUCTION " Plan 1.533 S .Ft. 2/4/2004 COMPONENT DESCRIPTION DESCRIPTION 1. OUTSIDE SURFACE AIR FILM 1 Gypsum or Plaster.Board 2 Membrane, Vapor -Permeable Felt 3 Insulation, Mineral Fiber, R-19 4 . Gypsum or Plaster Board 6 ASSEMBLY NAME JRA9WaII 19:2x6.16 172+5/8 GYP 1.06 7 0.26 8 ASSEMBLY Floor INSIDE SURFACE AIR FILM . 0:680 TYPE (check one) X Wall LU Ceiling ! Roof N FRAMING `MATERIAL TOTAL HC 2.3 FN— p Z FRAMING % 15 %. Framing % 16% (16" o.c. Wall) 1204 (24" o.c. Wall) 10% (16" o.c. Floor/Cell.) SKETCH OF ASSEMBLY 7%(24" o.c. Floor/CeiL) ■ ■ ■ ■ ■ ■ ■ DESCRIPTION 1. OUTSIDE SURFACE AIR FILM 1 Gypsum or Plaster.Board 2 Membrane, Vapor -Permeable Felt 3 Insulation, Mineral Fiber, R-19 4 . Gypsum or Plaster Board 6 2.87 6 1.06 7 0.26 8 9 INSIDE SURFACE AIR FILM . ■ ■ ■ ■ ■ ■ ■ CAVITY R -VALUE (Rc) 1. I o 1 .111 1 01 0.562 0.060 0.060 19:002. 5.'940 SUBTOTA R -VALUE CAVITY R -VALUE (Rc) WOOD FRAME R -VALUE ..0.170 0.170 0.5621 0.562 0.060 0.060 19:002. 5.'940 0.450 0.450 2.87 0.37 1.06 2.08 0.26 0.54 = 0,680 0:680 20.92 7.86 RC R 'HEAT CAPACITY (Optional) WALL WEIGHT (lbs%sf) SPECIFIC . HEAT (Btu/F4b) HC (A X B) (Btu/F-" members. [ 0.0478 2.60 - 0.26 0.68 0.06. 0.35 0.02 2.87 0.37 1.06 2.08 0.26 0.54 7.6 TOTAL HC 2.3 'NOTE: Weight and Specific Heat values for materials penetrated b wood framing include the effects of the framing members. [ 0.0478 X 0;85 ] +„ [ 0.1272 X 0.15 1 / Rc 1 - (Fr% / 100) 1 / Rf fr% 1100 ASSEMBLY U -VALUE COMMENTS EnergyPro 3.1 By Energysoft User Number: 5553. Job Number: LQ - 04 - T17 Page: 12 of 13 HVAC SYSTEM HEATING- AND .COOLING LOi4®S SUMMARY PROJECT NAME DATE " DGH CONSTRUCTION." Plan 1533 S .Ft. 2-/4/2004--... - SYSTEM NAME FLOOR AREA HVAC Split S. stem. Gas/bec 1,533 NGINEERING CHECKS SYSTEM LOAD Number of Systems 1 Heating System Output per System 32,000 Total Output (Btuh) 32,000 Output (Btuh/sgft) 20.9 Cooling System Output per System 35,200 Total Output (Btuh) 35,200 Total Output (Tons) 2.9 Total Output (Btuh/sgft) 23.0 Total Output (sgft/Ton) 522.6 Air System CFM per System 1,200 Airflow (cfm) 1,200 Airflow (cfm/sgft) 0.78 Airflow (cfm/Ton) 409.1 Outside Air Outside Air (cfm/sgft) 0.00 Note: values above.given at ARI conditions Total Room Loads Return Vented Lighting Retum Air Ducts Retum Fan Ventilation Supply Fan Supply Air Ducts COIL -'COOLING PEAK" COIL HTG: PEAK -COM-fSensiblel 791 Latent .I I CFM I Sensible 712 .12,841 0 791 19,797 0 642 990 0 0 = 00 :,;;:;• Supply Fan Heating Coil 0 0 0 0 642 990 TOTAL SYSTEM LOAD 1 J4.1251 0 21 ns HVAC EQUIPMENT SELECTION" York H4DH036/P4HUA12LO32 U&H 2'2,935 7,067 32,000 Total Adjusted System`Output935 7 �7 .. (Adjusted for Peak Design Conditions) -�� TIME OF SYSTEM PEAK Aug 2pm Jarrl2aml EATING .SYSTEM PSYCHROMETRICS- Airstream Tem eratures at Time of Heating: Peak 26.0 OF 69.20F 69.20F 94.3°F .: Supply Air Ducts Outside Air 0 cfm :,;;:;• Supply Fan Heating Coil 93,5 °F 1200 cfm ROOMS 70.0 OF 69.2 OF Retum Air Ducts DOLING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of. Coolin Peak 111.0/77.6°F 74.5/62.1°F 74.5/62.1°F 56.5 55.5 OF - .. - ;Supply Air Ducts Outside Air 0 cfm Supply Fan Cooling Coil 57:0 155.7 OF 1200 cfm ROOMS 50.996 R.H. 74.5 / 62.1 °F — 74.0161:9 OF Retum Air DU- . �. EnergyPro 3.1 Ey EnergySoft User Number: 5553 Job Number..LQ - 04 -T17-. Page: 13 of 13