06-2746 (SFD)P.O. BOX 1504
78-495 CALLE TAMPICO
LA QUINTA, CALIFORNIA 92253
BUILDING & SAFETY DEPARTMENT
BUILDING PERMIT
Applicant:
Architect or Engineer:
LICENSED CONTRACTOR'S DECLARATION
I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with
Section 7000) of Division 3 of the Business and Professionals Code, and my License is in full force'and effect.
License Class: License No.:
Date: Contractor: ,
OWNER -BUILDER DECLARATION '
I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the
following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to
construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the
permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State
License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or
that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by
any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars 155001.:,
(�) I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and
the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The
Contractors' State License Law does not apply to an owner of property who builds or improves thereon,
and who does the work himself or herself through his or her own employees, provided that the
improvements are not intended or offered for sale. If, however, the building or improvement is sold within
one year of completion, the owner -builder will have the burden of proving that he or she did not build or
improve for the purpose of sale.).
1 1 I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec.
7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of
property who builds or improves thereon, and who contracts for the projects with a contractors) licensed
pursuant to the Contractors' State License Law.).
(_ 1 I am exempt under Sec. , B.&P.C. for this reason '
A
—C9 C
CONSTRUCTION LENDING AGENCY
I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the
work for which this permit is issued (Sec. 3097, Civ. C.).
Lender's Name: _
Lender's Address:
LQPERnfIT
Owner:
CALDERON FRANCISCO B
53800 AVENIDA DIAZ
LA QUINTA, CA 92253
Other struct info
Contractor:
Owner.
DITION
VOICE (760) 777-7012
FAX (760) 777-7011
INSPECTIONS (760) 777-7153
Date: 10/16/06
2001/2005
------------–
WORKER'S COMPENSATION DECLARATION
I hereby affirm under penalty of perjury one of the following declarations:
I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided
for by Section 3700 of the Labor Code, for the performance of the work for which this permit is
issued.
I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor
Code, for the performance of the work for which this permit is issued. My workers' compensation
insurance carrier and policy number are:
Carrier 5.00 Policy Number NO
AL I certify that, in the performance of the work for which this permit is issued, I shall not employ any
person in any manner so as to become subject to the workers' compensation laws of California,
and.agree that, if I should become subject to the workers' com ensation provisions of Section
3700 of the Labor Cods all forthwith comply with{)ovisions.
WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL'
SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND
DOLLARS 1$100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN
SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES.
APPLICANT ACKNOWLEDGEMENT
IMPORTANT Application is hereby made to the Director of Building and Safety for a-perinivsubject-to the
conditions and restrictions set forth on this application.
1. Each person upon whose behalf this application is made, each person at whose request and for
whose benefit work is performed under or pursuant to any permit issued as a result of this application,
the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City
of La Quinta, its officers, agents and employees for any act or omission related to the work being
performed under or following issuance of this permit.
2. Any permit issued as a result of this application becomes null and void if work is not commenced
within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject
permit to cancellation.
I certify that I have read this application and state that the above information is correct. I agree to comply ith all
city and -county ordinances and state laws relating to building constructio y on repress tives
of this county to enter upon the above-mentioned property for ' ion purpii �i .
Application Number:
0 Y0000274--6
Property Address:
53540 AVENIDA RUBIO.
APN:
774-113-003-22 -000000-
Application description:
DWELLING - SINGLE FAMILY DETACHED
Property Zoning:
COVE RESIDENTIAL
Application valuation:
131388
Applicant:
Architect or Engineer:
LICENSED CONTRACTOR'S DECLARATION
I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with
Section 7000) of Division 3 of the Business and Professionals Code, and my License is in full force'and effect.
License Class: License No.:
Date: Contractor: ,
OWNER -BUILDER DECLARATION '
I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the
following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to
construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the
permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State
License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or
that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by
any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars 155001.:,
(�) I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and
the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The
Contractors' State License Law does not apply to an owner of property who builds or improves thereon,
and who does the work himself or herself through his or her own employees, provided that the
improvements are not intended or offered for sale. If, however, the building or improvement is sold within
one year of completion, the owner -builder will have the burden of proving that he or she did not build or
improve for the purpose of sale.).
1 1 I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec.
7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of
property who builds or improves thereon, and who contracts for the projects with a contractors) licensed
pursuant to the Contractors' State License Law.).
(_ 1 I am exempt under Sec. , B.&P.C. for this reason '
A
—C9 C
CONSTRUCTION LENDING AGENCY
I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the
work for which this permit is issued (Sec. 3097, Civ. C.).
Lender's Name: _
Lender's Address:
LQPERnfIT
Owner:
CALDERON FRANCISCO B
53800 AVENIDA DIAZ
LA QUINTA, CA 92253
Other struct info
Contractor:
Owner.
DITION
VOICE (760) 777-7012
FAX (760) 777-7011
INSPECTIONS (760) 777-7153
Date: 10/16/06
2001/2005
------------–
WORKER'S COMPENSATION DECLARATION
I hereby affirm under penalty of perjury one of the following declarations:
I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided
for by Section 3700 of the Labor Code, for the performance of the work for which this permit is
issued.
I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor
Code, for the performance of the work for which this permit is issued. My workers' compensation
insurance carrier and policy number are:
Carrier 5.00 Policy Number NO
AL I certify that, in the performance of the work for which this permit is issued, I shall not employ any
person in any manner so as to become subject to the workers' compensation laws of California,
and.agree that, if I should become subject to the workers' com ensation provisions of Section
3700 of the Labor Cods all forthwith comply with{)ovisions.
WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL'
SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND
DOLLARS 1$100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN
SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES.
APPLICANT ACKNOWLEDGEMENT
IMPORTANT Application is hereby made to the Director of Building and Safety for a-perinivsubject-to the
conditions and restrictions set forth on this application.
1. Each person upon whose behalf this application is made, each person at whose request and for
whose benefit work is performed under or pursuant to any permit issued as a result of this application,
the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City
of La Quinta, its officers, agents and employees for any act or omission related to the work being
performed under or following issuance of this permit.
2. Any permit issued as a result of this application becomes null and void if work is not commenced
within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject
permit to cancellation.
I certify that I have read this application and state that the above information is correct. I agree to comply ith all
city and -county ordinances and state laws relating to building constructio y on repress tives
of this county to enter upon the above-mentioned property for ' ion purpii �i .
Application Number . . . . . 06-00002746
Permit
. . .
BUILDING PERMIT
Additional
desc ..
Permit Fee
. . . .
751.50
Plan Check Fee
488.48
Issue Date
Valuation . . . .
131388
Expiration
Date..
4/14/07
Qty • Unit Charge
.Per
Extension
BASE
FEE
639.50
.32..00
3.5000
THOU BLDG
100,001-500,000
112.00
Permit
ELEC-NEW RESIDENTIAL
Additional
desc .
Permit Fee
113.89
Plan Check Fee
28.47
Issue Date
Valuation
0
Expiration
Date
.4/14/07
Qty Unit Charge
Per
Extension
BASE
FEE
15.00
2130.00
.0350
ELEC
NEW RES - 1 OR 2 FAMILY
74.55
467.00
.0200
ELEC
GARAGE OR NON-RESIDENTIAL
9.34
1.00
15.0000
EA ELEC
TEMPORARY POWER POLE
15.00.
Permit
GRADING PERMIT
Additional
desc .
Permit -Fee
. . . .
15.00
Plan Check Fee
.00
Issue Date
Valuation . . .
0
Expiration
Date
4/14/07
Qty Unit Charge
Per
Extension
BASE
FEE
15.00
Permit
. . .
MECHANICAL
'Additional
desc .
Permit Fee
. . . .
63.5.0
Plan Check Fee -.
15.88 .
Issue.DateValuation
- 0
Expiration
Date
4/14/07
Qty Unit Charge
Per*
Extension
BASE
FEE
15.00
1.00
9.0000
EA MECH
FURNACE <=100K
.9.00
.1.00
4.5000
EA MECH
VENT INST/ DUCT ALT.
4.50
1.00
9.0000
EA MECH
B/C <=3HP/100K BTU
9.00
3.•00
6.5000
EA MECH
VENT FAN
19.50
1.00
6.5000
EA MECH
EXHAUST HOOD
6.50
r
LQPERMIT
.. 11_1.;,.
ERMIT
Application Number
06-00002746
----------------------------------------------------------------------------
Permit
PLUMBING
Additional desc .
Permit Fee
155.25 Plan Check Fee..
38.81
Issue Date
Valuation
0
Expiration Date
4/14/07
Qty Unit Charge
Per
Extension
BASE FEE
15.00
15.00 6.0000
EA PLB FIXTURE
90.00
1.00 15.0000
EA PLB BUILDING SEWER
15.00
1.00 7.5000
EA PLB WATER HEATER/VENT
7.50
1.00 3.0000
EA PLB-WATER INST/ALT/REP
3.0.0
1.00 9.0.000
EA PLB LAWN SPRINKLER.SYSTEM
9.00'
4.00 3.0000
EA PLB GAS•PIPE 1-4 OUTLETS
12.00 .
5.00 .7500
EA PLB GAS PIPE >=5
3:75
--------------------------------------------------------------
Special Notes and Comments
--------------
2,130 SQ FT SF DWELLING/V-NR/RES-3.
THIS PERMIT DOES NOT
INCLUDE.
•BLOCKWALLS, POOL AND
SPA, OR DRIVEWAY
APPROACH.October 10,.
2006 3:20:49 PM
AORTEGA
----------------------------------------------------------------------------
Other Fees
. ART IN PUBLIC PLACES -RES
20.00
DIF COMMUNITY CENTERS -RES
74.00
DIF CIVIC CENTER -.RES
480.00
-ENERGY REVIEW FEE
.48.85
DIF FIRE PROTECTION -RES
140.00
GRADING PLAN CHECK FEE
.00
DIF•LIBRARIES - RES
355.00
DIF PARK.MAINT FAC -"RES
22.00
DIF PARKS/REC - RES
892.00
STRONG MOTION (SMI) -.RES
13.13
DIF STREET MAINT FAC -RES
67.00
7
DIF TRANSPORTATION - RES
1666.00
Fee summary Charged Paid Credited
Due
Permit Fee Total
1099.14 .00 .00,
1099.14
Plan Check Total
571.64 250.00 00.
321.64
Other Fee Total
3777.98 .00 .00
3777.98
Grand -Total
5448.76 250.00. .00
5198.76
Bin #
City of La Quinta
Building U Safety Division
P.O. Box 1504, 78-495 Calle Tampico
La Quinta, CA 92253 - (760) 777-7012
Building Permit Application and Tracking Sheet
Permit #l
/ �Z'� KJ
0
Project Address: s� _ sa,,, Qv\,C,Td
ame:
A. P. Number: �_ _ O
3 - �r90 /�
Legal Description:
Contractor:
ip: v%
+ °
elephone:
Address:
Project Description:
City, ST, Zip:
Telephone:"
State Lic. # :
City yic. #:
Arch., Engr., Designer:
Address:
City, ST, Zip:
Telephone:
State Lic. #:
Name of Contact Person:
Construction Type: Occupancy:
Project type (circle one): New Add'n Alter Repair. Demo
Sq. Ft.: 2,1 Z
# Stories:
# Units:
Telephone # of Contact Person:
Estimated Value of Project:
APPLICANT: DO NOT WRITE BELOW THIS LINE
#
Submittal
Req'd
Recd
TRACKING
PERMTI FEES
Plan Sets
Plan Check submitted
Item Amount
Structural Cates.
Reviewed, ready for corrections s
8 '3
Plan Check Deposit Z.S�
Truss Calcs.
Called Contact Person
Plan Check Balance
Energy Calcs.
Plans picked up
. Construction
Flood plain plan
Plans resubmitted
Mechanical
Grading plan
21" Review, ready for corrections/issue
Electrical
Subcontactor List
Called Contact Person
Plumbing
Grant Deed
Plans picked up
S.M.I.
H.O.A. Approval
Plans resubmitted
Grading
IN HOUSE:-
''" Review, ready for corrections/issue
Developer Impact Fee
Planning Approval
Called Contact Person
A.I.P.P.
Pub. Wks. Appr
Date of permit issue "
A
School Fees
JUL 20 2 O6
g�;
1 Ytx IJI S
q1 1 lotal -er it
w'L 17V Yb[ i �Lt NS fi T ip f (& FINANCE DEP k< IA)a) -1
Q jos �•yit ►�.
�J CIA
P)
CERTIFICATE OF COMPLIANCE S�k IED c
Desert Sands Unified School District �4C'i��o
47950 Dune Palms Road ¢ BERMUDA DUNES r
a�
q rn RANCHO MIRAGE Cf
Date 10/16/06 La QUinta, CA 92253 k_� INDIAN WELLS
�. PALM DESERT
No. 28969 (760) 771-8515 .y> LA QUINTAINDIO
�y
O
Owner
Francisco Calderon
APN # 774-113-003
Address
Jurisdiction La Quinta
City
Zip
Permit #
Tract #
Study Area
Type
Single Family, Residence
No. of Units 1
Lot # No. Street S.F..
Lot # No. Street S.F.
Unit 1
53540 Avenida Rubio 2130
Unit 6
Unit 2
Unit 7
Unit 3
Unit 8
Unit 4
Unit 9
Unit 5
-Unit 10
Comments
At the present time, the Desert Sands Unified School District does not collect fees on garages/carports, covered patios/walkways, residential additions under 5
00 square feet, detached accessory structures (spaces that do not contain facilities for living, sleeping, cooking, eating or sanitation) or replacement mobile ho
mes. It has been determined that the above-named owner is exempt from paying school fees at this time due to the following reason:.
EXEMPTION NOT APPLICABLE
This certifies that school facility fees imposed pursuant to
Education Code Section 17620 and Government Code 65995 Et Seq.
in the amount of $2.63 X 2,130 S.F. or $5,601.90 have been paid .for the property listed above and that
building permits and/or Certificates of Occupancy for this square footage in this proposed project may now be issued.
Fees Paid By OC/California Bk & Trust - Francisco Calderon Check No. 415782949
Name on the check Telephone
Funding Residential
By Dr. Doris Wilson
Superintendent
Fee collected /exemp d by h cGilvrey Payment Recd so.,36,77 F>�
$5,601.90 OverlUnder
�.,
Signature 3._; *•
NOTICE: Pursuant to Government Code Section 660 d(1 is will serve to notify you that the 90 -day approval period in. whicti you may protest the fees o
r other payment identified above will begin to run from the date on which the building or installation permit for this project is issued; or from the date on which
those amounts are paid to the District(s) or to another public entity authorized to collect them on the District('s) behalf, whichever is earlier.
NOTICE: This Document NOT VALID if Duplicated
Embossed Original- Building Department/Applicant Copy- Applicant/Receipt Copy -Accounting
w+.Te'y,sR1Rr^lyy�..�✓1^`.�eFaf`.�4._+.�sw{/IfsJ.aOV�03Ygjj:rA!..4•A1V'�.,+r
T-�"fi^'�lie�-.�.('�'.. - 6
4 ��
COACHEU`.A VALLEY WATER DISTRICT CASH.RECEIPT DETAIL.
11541`
Money
Order
Received From:
`
1
Date •
Address:- %! •s t ''
l._ i ` - r
��
/
f
Account No. ' � ' {
� � .�
�-- � i iti ° r `
Lot(s) Tract%-*N-
r-. (
L+
S r ice Address
-
TI? i , G:A: Code
j/S
❑ Backtlow(s)
I
❑ House Lateral(s)
t
❑ Detector Check(s)
❑ Copy to:.
Cash
Check
i
Money
Order
Water
Cashier
•CVWD-438 (1/05)
TITLE 24 REPORT
Title 24 Report for:
Caderon Residence
53-540 Avenida Rubio
La Quinta, CA
Project Designer:
t
Report Prepared By:
Joan D. Hacker
Insu-form, Inc.
41-921 Beacon Hill, Suite A
Palm Desert, CA 92211
(760) 779-0657
CITY OF LA QUINTA
BUILDING & SAFETY DEPT.
APPROVED
FOR CONSTRUCTION
DA C L�O BY
Job Number:
Date:
10/9/2006
The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is
authorized by the California Energy Commission for use with both the Residential and Nonresidential 2005 Building Energy Efficiency Standards.
This program developed by EnergySoft, LLC - www.energysoft.com.
EnergyPro 4.1 by EnergySoft Job Number: User Number: 2655
I TABLE OF CONTENTS I
Cover Page
Table of Contents
Form CF -1 R Certificate of Compliance
Form MF -1 R Mandatory Measures Summary
Form WS -5R Residential Kitchen Lighting
HVAC System Heating and Cooling Loads Summary
Room Load Summary
1
2
3
7
9
10
11
EnergyPro 4.1 by EnergySoft Job Number: User Number: 2655
Certificate Of Compliance:
Residential
❑ Addition
(Part 1 of 4) CF-1 R
S,qtlprnn Rpsdencp
Project Title
❑ Existing + Add/Alt
Building Front Orientation:
(W) 270 deg
10/9/2006
Date
9?-5_40AypnodgRubin I
Project Address
QI Iinta
Fenestration:
Number of Stories:
Building Permit #
InSIj-form Ing
219 ft 2
Avg. U: 0.71
(760) 779-0657
10.3% Avg.
Documentation Author
BUILDING ZONE
INFORMATION
Telephone
Plan Check/Date
FnprnvPm
Floor Area Volume
15
1 Field Check/Date
Compligrice Method
Climate Zone
TDV Energy Use
Standard
Proposed Compliance
(kBtu/sf-yr)
Design
Design
Margin
Space Heating
1.76
0.77
0.99
Space Cooling
47.66
49.25
-1.59
Fans
7.11
7.91
-0.80
Domestic Hot Water
18.41
16.95
1.46
Pumps
0.00
0.00
0.00
Totals
74.94
74.87
0.08
Percent better than Standard:
0.1 %
Building Type:
[-X] Single Family
❑ Addition
n/a ft2
❑ Multi Family
❑ Existing + Add/Alt
Building Front Orientation:
(W) 270 deg
Fuel Type:
8.5 ft
Propane
Fenestration:
Number of Stories:
1
Area:
219 ft 2
Avg. U: 0.71
Ratio:
10.3% Avg.
SHGC: 0.53
BUILDING ZONE
INFORMATION
Zone Name
Floor Area Volume
OPAQUE SURFACES
Type Frame Area U -Fac
Wall Wnnd 140 0 074
nnor None 36 0 500
Wall Wood 175 0 074
Wall Wnnd 505 n n74
Wall Wnnd 405 n n74
$nof Wood 2 130 0 025
Insulation Act.
Cay. Cont. Azm
Total Conditioned Floor Area:
2,130 ft2
Existing Floor Area:
n/a ft2
Raised Floor Area:
0 ft2
Slab on Grade Area:
2,130 ft2
Average Ceiling Height:
8.5 ft
Number of Dwelling Units:
1.00
Number of Stories:
1
# of Thermostat
Vent
Units Zone Type Type
Hgt. Area
Gains Condition
Tilt Y / N Status. JA IV Reference Location / Comments
nq-A5 I wing 7nnp
98-A4 I wing Zone
(19 -AS I wing Zone
nq_AS I wing 7nnp
nP-A5 I wing Zone
01-A1A Iiving7nne
: 1 1 : 1 1
,:1
■
-
1 EnergyPro 4.1 by EnergySoft User Number: 2655 Job Number: Page:3 of 11 1
Certificate Of Compliance: Residential (Part 2 of 4) CF -1 R
Caderon Residence 10/9/2006
Project Title Date
FENESTRATION SURFACES
Window
Condition
Status .
Overhang
Left Fin Right Fin
#
Exterior Shade Type
True Cond.
Location/
#
Type
Hgt. LExt.
RExt. Dist. Len. Hgt. Dist. Len. Hgt.
Area LI -Factor' SHGCz Azm. Tilt Stat. Glazing Type
Comments
0.76
Windnw
Front
(Wl
940 n 71 NERC X53 NFRr 270 qQ New mint Pana Windows
I Ming
7one
2
Window
Left
(N)
3.0 0.710 NFRC 0_53 NFRC 0 90 New Dual Pane Windows
Living
Zone
3
Window
Left
(N)
48.0 0.710 NFRC 0_53 NFRC 0 90 New Dual Pane Windows
Living
Zone
4
Window
Left
(N)
24.0 0.710 NFRC 0_53 NFRC 0 90 New Dual Pane Windows
Living
Zone
5
Window
Rear
(E)
3.0 0.710 NFRC 0_53 NFRC 90 90 New Dual Pane Windows
Living
Zone
6
Window
Rear
(E)
48.0 0.710 NFRC0 53 NFRC 90 90 New Dual Pane Windows
Living
Zone
L
Window
Rear
(E)
24-0 0-71 NF$Q_Q-U NFRC 90 90 New Dual Pane Windows
Living
Zone
8
Window
Right
(S)
9.0 0.710 NFRC 0_53 NFRC 180 90 New Dual Pane Windows
Living
Zone
5
Window
Right
(S)
3.0 0.710 NFRti 0.53 NFRC 180 '90 New -Dual Pane Windows
Living
Zone
1Q
Window
Right
(S)
24.0 0.710 NFRC 0.53 NFRC 180 90 New Dual Pane Windows
Living
Zone
10
Window
Right
(S)
9.0 0_710 NFRC0 53NFRC 180 90 New Dual Pane Windows
Living
Zone
1. Indicate source either from NFRC or Table 116A. 2. Indicate source either from NFRC or Table 1168.
INTERIOR AND EXTERIOR SHADING
Window
Condition
Status .
Overhang
Left Fin Right Fin
#
Exterior Shade Type
SHGC
Hgt.
Wd.
Len.
Hgt. LExt.
RExt. Dist. Len. Hgt. Dist. Len. Hgt.
1
Bug Screen
0.76
4.0
6.0
2.0
0.1 2.0
2.0
2
Bug Screen
0.76
1.0
3.0
2.0
0.1 '2.0
2.0
3
Bug Screen
0.76
8.0
6.0
2.0
0.1 2.0
2.0
4
Bug Screen
0.76
4.0
6.0
2.0
0.1 2.0
2.0
5
Bug Screen
0.76
1.0
3.0
2.0
0.1 2.0
2.0 _
6
Bug Screen
0.76
8.0
6.0
2.0
0.1 2.0
2.0 _
7
Bug Screen
0.76
4.0
6.0
2.0
0.1 2.0
2.0
8
Bug Screen
0.76
1.0
3.0
2.0
0.1 2.0
2.0
9
Bug Screen
0.76
1.0
3.0
2.0
0.1 2.0
2.0
10
Bug Screen
0.76
1.0
3.0
2.0
0.1 2.0
2.0 _
11
Bug Screen
0.76
3.0
3.0
2.0
0.1 2.0
2.0
THERMAL MASS FOR HIGH MASS DESIGN
Type
Area Thick. Heat Inside
(so (in.) Cap. Cond. R -Val. JA IV Reference
Condition
Status .
Location/
Comments
PERIMETER LOSSES
Insulation
Condition
Location/
Type
Length R -Val. Location JA IV Reference
Status
Comments
Slab Perimeter
53 None No Insulation 26-A1
New
Living Zone
Run Initiation Time: 10/09/06 16:22:50 Run Code: 1160436170
EnergyPro 4.1 by EnergySoft User Number: 2655 Job Number: Page:4 of 11
Certificate Of Compliance: Residential (Part 3 of 4) CF -1 R
Caderon Residence 10/9/2006
Project Title Date
HVAC SYSTEMS
Heating Minimum Cooling Minimum Condition Thermostat
Location Type Eff Type Eff Status Type
Living Zone Larqe Split Heat Pump 8.10 COP Split Heat Pump 13.0 SEER New Setback
HVAC DISTRIBUTION
Duct Duct Condition Ducts
Location Heating Cooling Location R -Value Status Tested?
Living Zone Ducted Ducted Attic 6.0 New Yes
Hydronic Piping Pipe Pipe Insul.
System Name Length Diameter Thick.
WATER HEATING SYSTEMS Ratedl
Tank
Energy
Standbyl Tank Insul.
Water Heater # in Input
Cap.
Condition Factor
Loss R -Value
System Name Type Distribution Syst. (Btu/hr)
(gal)
Status or RE 1
(%) Ext.
A O SMITH PGCG-50-246 Small Gas . Kitchen Pipe Ins 1 40,000
50
New 0.62
n/a n/a
Multi -Family Central Water Heating Details
Hot Water Pump Hot Water Piping Length (ft) Add 1/2"
Control # HP Type In Plenum Outside Buried Insulation
1 For small gas storage (rated input — 75000 Btu/hr), electric resistance and heat pump water heaters, list energy factor.
For large gas storage water heaters (rated input > 75000 Btu/hr), list Rated Input, Recovery Efficiency and Standby Loss.
For instantaneous gas water heaters, list Rated Input, and Recovery Efficiency.
REMARKS
COMPLIANCE STATEMENT
This certificate of compliance lists the building features and specifications needed to comply with Title 24, Parts 1 and 6 of the California Code of
Regulations, and the administrative regulations to implement them. This certificate has been signed by the individual with overall design responsibility.
The undersigned recognizes that compliance using duct design, duct sealing, verification of refrigerant charge and TXVs, insulation installation quality,
and building envelope sealing require installer testing and certification and field verification by an approved HERS rater.
Designer or Owner (per Business & Professions Code)
Name:
Title/Firm:
Address:
Telephone:
Lic. #:
(signature) (date)
Enforcement Agency
Name:
Title/Firm:
Address:
Telephone:
Documentation Author
Name: Joan D. Hacker
Title/Firm: Insu-form, Inc.
Address: 41-921 Beacon Hill, Suite
Palm Desert, CA 92211
Telephone: (760) 779-0657
WW,IC• i 1
Certificate Of Compliance: Residential (Part 4 of 4) CF -1 R
Caderon Residence 10/9/2006
Project Title Date
Special Features and Modeling Assumptions
The local enforcement agency should pay special attention to the items specified in this checklist. These items require special
written justification and documentation, and special verification to be used with the performance approach. The local enforcement
anenry determines the adeauacv of the iustification. and may reiect a building or design that otherwise complies based on the
adequacy of the special justification and documentation submitted.
Plan I Field
HERS Required Verification
Items in this section require field testing and/or verification by a certified home energy rater under the supervision of a CEC-
approved HERS provider using CEC approved testing and/or verification methods and must be reported on the CFAR Plan Field
installation certificate.
The HVAC System "Living Zone" incorporates HERS verified Duct Leakage. Target leakage is calculated and documented on the CF -
4R.
The HVAC System "Living Zone" incorporates a HERS verified Refrigerant Charge test or a HERS verified Thermostatic Expansion
Valve.
The Cooling System "Carrier 38YXA06033" includes credit for a 10.7 EER Condenser. A certified HERS rater must field verify the
installation of the correct Condenser.
EnergyPro 4.1 by EnergySoft User Number: 2655 Job Number: Page:6 of 11 1
Mandatory Measures Summary: Residential (Page 1 of 2) MF -1 R
NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. More stringent
compliance requirements from the Certificate of Compliance supercede the items marked with an asterisk (7 below. When this checklist is incorporated
into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory
measures whether they are shown elsewhere in the documents or on this checklist only.
DESCRIPTION Instructions: Check or initial applicable boxes when completed or check N/A if not
applicable.
N/A
DESIGNER
ENFORCE -
MENT
Building Envelope Measures
❑
❑X
❑
*§ 150(a): Minimum R-19 in wood ceiling insulation or equivalent U -factor in metal frame ceiling.
❑
❑X
❑
§ 150(b): Loose fill insulation manufacturers labeled R -Value:
❑ '
❑
❑
§ 150(c): Minimum R-13 wall insulation in wood framed walls or equivalent LI -factor in metal frame walls (does not
F
Q
❑
apply to exterior mass walls).
❑
1K
❑
;§ 150(d): Minimum R-13 raised floor insulation in framed floors or equivalent U -factor.
❑
❑
❑
§ 150(e): Installation of Fireplaces, Decorative Gas Appliances and Gas Logs.
❑
❑X
❑
1. Masonry and factory -built fireplaces have:
❑
Q
❑
a. closable metal or glass door covering the entire opening of the'firebox
❑
❑X
❑
b. outside air intake with damper and control, flue damper and control
❑
0
❑
2. No continuous burning gas pilot lights allowed.
❑
1K
❑
§ 150(f): Air retarding wrap installed to comply wit§ 151 meets requirements specified in the ACM Residential Manual.
❑
0
❑
§ 150(g): Vapor barriers mandatory in Climate Zones 14 and 16 only.
❑
❑
❑
§ 150(1): Slab edge insulation - water absorption rate for the insulation alone without facings no greater than 0.3%, water vapor
❑
❑
❑
permeance rate no greater than 2.0 permfinch.
❑
FX
❑
§ 118: Insulation specified or installed meets insulation installation quality standards. Indicate type and
❑
0
❑
include CF -6R Form:
❑
191
❑
§ 116-17: Fenestration Products, Exterior Doors, and Infiltration/Exfiltration Controls.
1.' Doors and windows between conditioned and unconditioned spaces designed to limit air leakage.
❑
❑X
❑
2. Fenestration products (except field fabricated) have label with certified U -Factor, certified Solar Heat Gain
❑
1K
El
(SHGC), and infiltration certification.
3. Exterior doors and windows weatherstripped; all joints and penetrations caulked and sealed.
❑
❑X
❑
Space Conditioning, Water Heating and Plumbing System Measures
§ 110-13: HVAC equipment, water heaters, showerheads and faucets certified by the Energy Commission.
❑
❑X
❑
§ 150(h): Heating and/or cooling loads calculated in accordance with ASHRAE, SMACNA or ACCA.
❑
❑X
❑
§ 150(i): Setback thermostat on all applicable heating and/or cooling systems.
❑
Q
❑
§ 1506): Water system pipe and tank insulation and cooling systems line insulation.
1. Storage gas water heaters rated with an Energy Factor less than 0.58 must be externally wrapped with
❑
a
❑
insulation having an installed thermal resistance of R-12 or greater.
2. Back-up tanks for solar systems, unfired storage tanks, or other indirect hot water tanks have R-12 external
❑
❑X
❑
insulation or R-16 internal insulation and indicated on the exterior of the tank showing the R -value.
3. The following piping is insulated according to Table 150-A/B or Equation 150-A Insulation Thickness:
1. First 5 feet of hot and cold water pipes closest to water heater tank, non -recirculating systems, and entire
❑
FX
❑
length of recirculating sections of hot water pipes shall be insulated to Table 150B.
2. Cooling system piping (suction, chilled water, or brine lines), piping insulated between heating source
❑
191
❑
and indirect hot water tank shall be insulated to Table 150-B and Equation 150-A.
4. Steam hydronic heating systems or hot water systems > 15 psi, meet requirements of Table 123-A.
❑ '
❑X
❑
5. Insulation must be protected from damage, including that due to sunlight, moisture, equipment
❑
❑X
❑
maintenance, and wind.
6. Insulation for chilled water piping and refrigerant suction piping includes a vapor retardant or is enclosed
❑
❑
❑
entirely in conditioned space.
7. Solar water -heating systems/collectors are certified by the Solar Rating and Certification Corporation.
❑
❑
❑
EnergyPro 4.1 by EnergySoft User Number: 2655 Job Number:
Page:7 of 11
Mandatory Measures Summary: Residential (Page 2 of 2) MF -1 R
NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. More stringent
compliance requirements from the Certificate of Compliance supercede the items marked with an asterisk (7 below. When this checklist is incorporated
into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory
measures whether they are shown elsewhere in the documents or on this checklist only.
Instructions: Check or initial applicable boxes when completed or check N/A if not
ENFORCE -
DESCRIPTION
applicable.
N/A DESIGNER MENT
Space Conditioning, Water Heating and Plumbing System Measures: (continued)
§ 150(m): Ducts and Fans
1. All ducts and plenums installed, sealed and insulated to meet the requirements of the CMC Sections 601, 602, 603, 604,❑
X❑ ❑
605, and Standard 6-5; supply -air and return -air ducts and plenums are insulated to a minumum installed level of
R-4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct -closure system
that meets the applicable requirements of UL 181, UL 181A, or UL 181B or aerosol sealant that meets the requirements
of UL 723. If mastic or tape is used to seal openings greater than 1/4 inch, the combination of mastic and either mesh
or tape shall be used.
2. Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than
❑ x❑ ❑
sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and
support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause
reductions in the cross-sectional area of the ducts.
3. Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive
❑ ® ❑
duct tapes unless such tape is used in combination with mastic and draw bands.
❑ ® ❑
4. Exhaust fan systems have back draft or automatic dampers.
5. Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operating
❑ ® ❑
dampers.
6. Protection of Insulation. Insulation shall be protected from damage, including that due to sunlight, moisture, equipment
❑ ® ❑
maintenance, and wind. Cellular foam insulation shall be protected as above or painted with a coating that is water
retardant and provides shielding from solar radiation that can cause degradation of the material.
❑ ® ❑
7. Flexible ducts cannot have porous inner cores.
§ 114: Pool and Spa Heating Systems and Equipment
1. A thermal efficiency that complies with the Appliance Efficiency Regulations, on-off switch mounted outside of the
❑ ❑ ❑
heater, weatherproof operating instructions, no electric resistance heating and no pilot light.
2. System is installed with:
❑ ❑ ❑
a. At least 36" of pipe between filter and heater for future solar heating.
b. Cover for outdoor pools or outdoor spas.
❑ ❑ ❑
3. Pool system has directional inlets and a circulation pump time switch.
❑ ❑ ❑
§ 115: Gas fired fan -type central furnaces, pool heaters, spa healers or household cooking appliances have no continuously
❑ ❑ ❑
burning pilot light. (Exception: Non -electrical cooking appliances with pilot < 150 Btu/hr)
§ 118 (i): Cool Roof material meets specified criteria
❑ ❑ ❑
Lighting Measures
§ 150(k)l: HIGH EFFICACY LUMINAIRES OTHER THAN OUTDOOR HID: contain only high efficacy lamps as outlined in Table
❑ ® ❑
150-C, and do not contain a medium screw base socket (E24/E26). Ballasts for lamps 13 Watts or greater are
electric and have an output frequency no less than 20 kHz.
§ 150(k)1: HIGH EFFICACY LUMINAIRES - OUTDOOR HID: contain only high efficacy lamps as outlined in Table 150-C,
❑ X❑ ❑
luminaire has factory installed HID ballast.
§ 150(k)2: Permanently installed luminaires in kitchens shall be high efficacy luminaires. Up to 50% of the Wattage, as determined
❑ X❑ ❑
in Section 130(c), of permanently installed luminaires in kitchens may be in luminaires that are not high efficacy luminaires,
provided that these luminaires are controlled by switches separate from those controlling the high efficacy luminaires.
§ 150(k)3: Permanently installed luminaires in bathrooms, garages, laundry rooms, utility rooms shall be high efficacy luminaires.
❑ a ❑
OR are controlled by an occupant sensor(s) certfied to comply with Section 119(d).
§ 150(k)4: Permanently installed luminaires located other than in kichens, bathrooms,garages, laundry rooms, and utility rooms
shall be high efficacy luminaires (except closets less than 70 ft) OR are controlled by a dimmer switch OR are
❑ X❑ ❑
controlled by an occupant sensor that complies with Section i 19(d) that does not turn on automatically or have an
always on option.
§ 150(k)5: Luminaires that are recessed into insulated ceilings are approved for zero clearance insulation cover (IC) and are
❑ X❑ ❑
certified to ASTM E283 and labeled as air tight (AT) to less than 2.0 CFM at 75 Pascals.
§ 150(k)6: Luminaires providing outdoor lighting and permanently mounted to a residential building or to other buildings on the
❑ x❑ ❑
same lot shall be high efficacy luminaires (not including lighting around swimming pools/water features or other Article
680 locations) OR are controlled by occupant sensors with integral photo control certified to comply with Section 119(d).
§ 150(k)7: Lighting for parking lots for 8 or more vehicles shall have lighting that complies with Sections 130, 132, and 147.
❑ ❑ ❑
Lighting for parking garages for 8 or more vehicles shall have lighting that complies with Section 130, 131, and 146.
§ 150(k)8: Permanently installed lighting in the enclosed, non -dwelling spaces of low-rise residential buildings with four or more
❑ ❑ ❑
dwelling units shall be high efficacy luminaires OR are controlled by occupant sensor(s) certified to comply with Section
119(d).
EnergyPro 4.1 by EnergySoft User Number: 2655 Job Number:
Page:8 of 11
0
Residential Kitchen Liqhtinq Worksheet WS -5R
Caderon Residence 10/9/2006
Project Title Date
At least 50% of the total rated wattage of permanently installed luminaires in kitchens must be in luminaires that are high efficacy luminaires
as defined in Table 150-0. Luminaires that are not high efficacy must be switched separately.
Kitchell Lighting Schedule. Provide the following information for all luminaires to be installed in kitchens.
High Efficacy
Luminaire Type High Efficacy? Watts Quantity Watts Other Watts
(1) 40w Fluorescent Twin MagEE Yes X No 43.0 x 4 = 172 or
Yes No x = or
Yes No x = or
Yes No x• = or
Yes No x = or
Yes No x = or
Yes No x = or
Yes No x = or
Yes No x = or
Yes No x = or
Yes No x = or
Yes No x = or
Yes No x = or
Yes I No x = or
Yes No x = or
Yes No x = or
Yes No x = or
Yes No x = or
Yes No x = or
Yes No x = or
Total A: 172 B: 0
COMPLIES IF A>_ B YES ® NO ❑
EnergyPro 4.1 by EnergySofi User Number: 2655 Job Number: Page:9 of 11
1HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY
PROJECT NAME DATE
Caderon Residence 10/9/2006
SYSTEM NAME FLOOR AREA
Living Zone 2,130
ENGINEERING CHECKS 11SYSTEM LOAD
Number of Systems
1
Heating System
Output per System
80,000
Total Output (Btuh)
80,000
Output (Btuh/sqft)
37.6
Cooling System
Output per System
58,000
Total Output (Btuh)
58,000
Total Output (Tons)
4.8
Total Output (Btuh/sqft)
27.2
Total Output (sgft/Ton)
440.7
Air System
CFM per System
1,595
Airflow (cfm)
1,595
Airflow (cfm/sgft)
0.75
Airflow (cfmrron)
330.0
Outside Air (%)
0.0
Outside Air (cfm/sgft)
0.00
Note: values above given at ARI conditions
JEATING SYSTEM PSYCHROMETRICS
26.0 OF 69.0 OF 69.OoF
Outside Air
0 cfm
69.0 of
Total Room Loads
Return Vented Lighting
Return Air Ducts
Return Fan
Ventilation
Supply Fan
Supply Air Ducts
TOTAL SYSTEM LOAD
COIL COOLING PEAK
COIL HTG. PEAK
CFM
I Sensiblel
Latent
CFM
I Sensible
924
25,072
2,620
833
24,397
0
79.5/61.2OF 79.5/61.3oF
50.9/49.50F
2,624
1,638
0
0
0
0
0
0
0
0
0
2,624
1,638
30,3211 2 620 27 672
HVAC EQUIPMENT SELECTION
Carrier 38YXA06033 48,549 0 49,966
Total Adjusted System Output 48 549 0 49,966
(Adjusted for Peak Design Conditions)
TIME OF SYSTEM PEAK Aug 2 pm Jan 12 am
Supply Fan Heating Coil
1595 cfm
98.5 OF
k Return Air Ducts 4
Supply Air Ducts
97.5 of
ROOMS
70.0 of
DOLING SYSTEM PSYCHROMETRICS Airstream Temperatures
at Time of Cooling
Peak
111.9/77.6OF
79.5/61.2OF 79.5/61.3oF
50.9/49.50F
;114Outside
"
Supply Air Ducts
Air
0 cfm
Supply Fan Cooling Coil
52.5 / 50.1 of
1595 cfm
ROOMS
36.4% R.H.
79.5/61.20F
78.0/60.70F
Return Air Ducts
I
EnergyPro 4.1 by EnergySoft
User Number: 2655
Job Number:
Page:10 of 11
ROOM LOAD SUMMARY
PROJECT NAME DATE
Caderon Residence 10/9/2006
SYSTEM NAME FLOOR AREA
Livina Zone 2,130
ROOM LOAD SUMMARY
ROOM COOLING PEAK
COIL COOLING PEAK
COIL HTG. PEAK
ZONE NAME
ROOM NAME
Mult.
CFM
SENSIBLE
LATENT
CFM
SENSIBLE
LATENT
CFM
SENSIBLE
LivingLiving Zone
1
924
25,072
2,620
924
25,072
2,620
833
24,397
PAGE TOTAL 1 924 25,072 2,620 833 24,397
TOTAL 1 924 25,072 F 2,620 833 24,397
EnergyPro By EnergySoft User Number: User Job Number: Page: 11 of 11