Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
06-3488 (AR)
Ar P.O. BOX 1504 78-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 Application Number: Property Address: APN: Application description Property Zoning: Application valuation: Applicant: (`06x00003488_: 53800 AVENIDA RUBIO 774-153-024-21 -000000- ADDITION - RESIDENTIAL COVE RESIDENTIAL 29973 Architect or Engine BUILDING & SAFETY DEPARTMENT BUILDING PERMIT LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professionals Code, and my License is in full force and effect. License Class: License No.: Date: Contractor: OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the following reason (Sec. 7031 .5, Business and Professions Code: Any city or'county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement'that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or tha/h she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by arcant fora permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500):: , as owner of the property, or my employees with wages as their sole compensation, will do the work, and t.r the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). (_ 1 I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec.. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). I 1 I am exempt under Sec. , B.&P.C. for this reason 0w ier.- V CONSTRUCTION LEND&d AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Name: _ Lender's Address: LQPEXMIT Owner: PEREZ JODY J 53800 RUBIO LA QUINTA, CA 92253 ( Contractor: Owner VOICE (760) 777-7012 FAX (760) 777-7011 INSPECTIONS (760) 777-7153 Date: 2/05/07 WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier ...r Policy Number ,- certify that, in the performance of the work for which this permit is issued, I shall not employ any -" person in any manner so as to become subject to the workers' compensation laws of California, and agree that, if I should becb9' a subject to the workers' compensation provisions of Section 377100 of the Labor o , I s rPMPENS7ATIONCOVERAGE comply with those provisrs. Dater (+��Applicant: WARNING: FAILURE TO SECURE RKERS' IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRI NAL PENALTIES AND UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. . APPLICANT ACKNOWLEDGEMENT IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the conditions and restrictions set forth on this application. . 1 . Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application, the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit,. or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this county to center upon the above-mentionedrop ty for in c ion purposes. � bate' Vs Signature (Applicant or_Agen Application Number . . . . 06-00003488 ------ Structure Information 524 SF RM ADDITION/V-NR/RES-3/[ENG] ----- Other struct info . . . . . CODE'EDITION 2001/2005 # BEDROOMS 1.00 FLOOD ZONE NO' -------7-------------------------------------------------------------------- 1ST FLOOR SQUARE FOOTAGE 524.00 �' Permit BUILDING PERMIT Additional desc .,. Permit Fee . . . . 284.50 Plan Check Fee 184.93 Issue Date . . . . Valuation . . . . 29973 Expiration Date 8/04/07 Qty Unit Charge Per Extension BASE FEE 252.00 5.00 6.5000 ---------------------------------------------------------------------------- THOU BLDG 25,001-50,000 32.50 Permit . ... . . ELECT - ADD/ALT/REM Additional desc . Permit Fee 39.00 Plan Check Fee 9.75 Issue Date . . . Valuation . . . . 0 Expiration Date 8/04/07 Qty Unit Charge Per Extension BASE FEE 15.00 20.00 .7500 PER ELEC DEVICE/FIXTURE;1ST 20 15.00 20.00 .4500 -------------------------- EA ELEC ------------ DEVICE/FIXTURE >20 ---------------------- 9.00 ---------------- Permit MECHANICAL Additional desc . Permit Fee . . . . 44.00 Plan Check Fee 11.00 Issue Date . . . . Valuation . . . . 0 Expiration Date 8/04/07 Qty Unit Charge Per Extension BASE FEE 15.00 1.00. 9.0000 EA MECH FURNACE <=100K 9.00 1.00 4.5000 EA MECH VENT INST/ DUCT ALT 4'.50 1.00 9.000Q EA MECH B/C <=3HP/100K BTU 9.00 1.00 6.5000 ---------------------------------------------------------------------------- EA MECH VENT FAN 6.50 Permit . . . PLUMBING Additional desc . Permit Fee 36.00 LQPERNIT Plan Check Fee . . 9.00 Application Number . . . . . 06-00003488 Permit . . . . PLUMBING Issue Date . . . . Valuation . . . . 0 Expiration Date 8/04/07 Qty Unit Charge Per Extension BASE FEE 15.00 3.00 6.0000 EA PLB FIXTURE 18.00 1.00 3.0000 EA PLB WATER INST/ALT/REP 3.00 ---------------------------------------------------------------------------- Special Notes and Comments. 524SF ROOM ADDITION/V-NR/RES-3/CLASS A-.FR/[ENGINEERED]. THIS PERMIT DOES NOT INCLUDE BLOCKWALLS. February 2, 2007 12:03:59 PM AORTEGA ---------------------------------------------------------------------------- Other Fees . . . . . . . . . ENERGY REVIEW FEE 18.49 STRONG MOTION (SMI) - RES 2.99 Fee summary Charged Paid Credited ----------------- ---------- ---------- ---------- ---------- Due ' Permit Fee Total 403.50 .00 .00 403.50 Plan Check Total 214.68 .00 .00 214.68 Other Fee Total 21.48 .00 .00 21.48 Grand Total 639.66 .00 .00 639.66 LQPERA1IT i CERTIFICATE OF COMPLIANCE 4�'�� IEDIF Desert Sands Unified School District tcc) 47950 Dune Palms Road Q BERMUDA DUNES Cn Date 2/9/07 La Quinta, CA 92253 {� R INANCHO DIAN WELLSE PALM DESERT y No. 29219 (760) 771-8515 u'y �QINDIO yr'l� O Owner Jody Perez APN # 774-153-024 Address 53-800 Avenida Rubio Jurisdiction La Quinta City La Quinta Zip Permit # Tract # Study Area Type Residential Addition No. of Units 1 Lot # No. Street S.F. Lot # No. Street S.F. Unit 1 53800 Avenida Rubio Unit 2 Unit 3 Unit 4 Unit 5 Comments 524 Unit 6 Unit 7 Unit 8 Unit 9 Unit 10 At the present time, the Desert Sands Unified School District does not collect fees on garages/carports, covered patios/Walkways, residential additions under 5 00 square feet, detached accessory structures (spaces that do not contain facilities for living, sleeping, cooking, eating or sanitation) or replacement mobile ho mes. It has been determined that the above-named owner is exempt from paying school fees at this time due to the following reason: EXEMPTION NOT APPLICABLE This certifies that school facility fees imposed pursuant to Education Code Section 17620 and Government Code 65995 Et Seq. in the amount of $2.63 X 524 S.F. or $1,378.12 have been paid for the property listed above and that building permits and/or Certificates of Occupancy for this square footage in this proposed project may now be issued. Fees Paid By CC/1st Bank - Jody Perez Check No. 82374 Name on the check Telephone Funding Residential By Dr. Doris Wilson Superintendent �.. r Fee collected lexemp y r4Gilv Payment Recd y$0.00 "` r $1,378.12 -Over/Under -2 Signature NOTICE: Pursuant to Government Code Section 66020(d)o, this will serve to notify you that the 90 -day approval period in which you may protest the fees o r other payment identified above will begin to run from the date on which the building or installation permit for this project is issued, or from the date on which those amounts are paid to the District(s) or to another public entity authorized to collect them on the District('s) behalf, whichever is earlier. NOTICE: This Document NOT VALID if Duplicated Embossed Original - Building Department/Applicant Copy - Applicant/Receipt Copy - Accounting �t CITY OF LA QUINTA SUB -CONTRACTOR LIST-' 7T JOB ADDRESS :?-'800 AV& PERMIT NUMBER OWNER & tJ ILDER This form shall be on the job with the Building Inspection Card at all times in a conspicuous place. Only persons appearing o st .or their employ s are authorized to work on this job. Any.changes to this list must be approved by the Building Division prior to commencement of work. Failure to comply will result in a stoppage of work and/or the voidance ♦._A ..1! a .. +ftA kn1na.I m. 1Ct hra f'nrnnlPtPrl hV annlirant_ "On Fite" is not an acceptable response. of building permit. For Udell OpPlIUCUIG UCIJG, O.. 1" %J1414ua.v...c,yVV.aaV. Contractor :.:' —w— .,, . v ... r....-_.- -, :::.<>:<::::;<:::?:;::State:::Contractors License:Workers Classification License Number Exp. Date (e.g. A. B, C-8) (xxxxxx) (xx/xx/xx) -r-v • ----- --- - --- -- ::..:. Com ensabon;Insurance':.``: Carrier Name Policy Number Exp. Date le.g. State Fund, CalComp) (Format Varies) (xx/xx/xx) City Business Licen . License Number Exp. Date (xxxx) (xx/xx/xx) Trade / Classification Company Name EARTHWORK (C-12) ::; A11A CONCRETE IC -81 Ll/I�/C �mhC�G�C. ��� /`1���� 3 /� /�L'-61-ND3 s /\���/�l9 i /� C ✓ 317o FRAMING :(C-5) Q(,�/�/ �Ui��r•2_ STRUCT'.:STEEL MASONRY (C-291 PLUMBING (C-361 / //i�G /�f// // C'3� S/. f� n /;^.d�taga / (/�iE/ / 03' l�n . �7 J °3 , y 3y3 3�1 LATA"; PLASTER 35) otdn �l DRYWALL (C-9)..::. ./,O Vo S, jai` I �ISoo3 i��d` �r O HVAC.IC-20Y.::. . ;. .. g/L{CZES 10 131 ® I € � E eA of4,1., to ���IS�7 1gb� /b , a 3�� ELECTRICAL.(C-101: e� C—/ti. �C� 7Z.. �� erF i%f p �6t'itajo. ew € ii����-QC%�1� a 1 C7gj 5,` %� �0 3�. o% ROOFING.IC 391`.: '', `:r. X5 1 ; 1(,� c- -7oggo I(130 <j4-.(�o�a�;®r3 3� .�� (y3� bpi- lob ! �r(�'c1£� � p 0 v� SHEET METAL (C=43) �. FLOORING (C". SY. GLAZING (C-17)` INSULATION (C-2): SEWAGE DISP (6-42) . PAINTING CERAMIC TILE (C-54) n efl_, CABINETS IC -6) p FENCING (C7'13) LANDSCAPING (C=27.1. tj POOL (C-53)% --A _... IR CO > Ii• a ............... .._..._.........__._._....._......_......... - - ...__.._........ _...,......._................. _.. ......_.... ....... ..._. ............. S .=IRSf A IERICAN TITLE COMPANY DOC ' # 2 06=03°49026 REs 1EQlJIAL DIVISION 03/ 12/20011f;'08: 00A' Fee: 11. 00 Pefie l of 3 RECORDING REQUESTED BY• Recorded Lr official Records County cf Riverside First American Title _ Lari-y U. hard A AND WHEN RECORDED MAIL TO: ssessor, , County Clerk &Recorder JODY PEREZ Illlilll III 1111111 iii lllli sill sill KATHERINE PEREZ I1II1I1III11IIlIIlI11 53800 Avenida Rubio Rubio, CA 92253 - Title Order No. 2328492 Escrow No. 400721 -GK ©©0lm®m�I . .- ®�® A.P.N. 774-153-024-1-�(�Q�•• �' �'" NUE MMMMWMMM- `, _ Grant Deed THE UNDERSIGNED GRANTOR(S) DECLARE(S) I City Transfer Tax is $0.00 k County Transfer Tax is $0.00 TC (X ), . Computed on. the full consideration or value of property conveyed OR' ( ) Computed on the full consideration or valueless liens or encumbrances remaining at time of sale (X) City of La Quinta, and FOR A VALUABLE CONSIDERATION, receipt of which is hereby -acknowledged, JODY PEREZ and KATHERINE PEREZ hereby GRANT(S) to JODY PEREZ and KATHERINE PEREZ, husband and wife as joint tenants the real property in the City of La Quinta, County of Riverside, State of California, described as: Lot 20 and 21 of Block 201 Santa Carmelita at Vale La Quinta Unit #19 as per map recorded in Book 19 Pages 33 and 34 of Maps, in the Office of the County Recorder of said Riverside County. The legal description is pursuant to that Notice of Lot Merger recorded June 21, 1989 as Instrument No. 89-205190 of Official Records. 9 DY E Z KA NE PEREZ Dated April 19, 2006 State of California ) Coun of - R i V f" -S I cl,- )SS �vE t,..ytJ aA, t4Els y, On c+c-�t /� ..D� �o before me, Wdod �gAi, a Notary Public in and for said State, personally ap red Jody Perez and Katherine Perez personally known to me (ow. proved 49basis of a 'device) -to be the`person(s) whose names(s) Ware subscribed to the within instrument and acknowledged to me that helsbefthey executed the same in hisfher/their authorized capacity(ies), and that by his.# r/their signature(s) on the instrument the person(s), or the entity upon behalf of which the person(s) acted, executed the instrument. WITNESS my hand and official seal. EirELYPI H. ID:LSEY Commission # 1368?N41 Z i Notary Public - CaRforroa - Riverside County Signature ��r"Mrrww, E°*mAugBZppg MAIL TAX STATEMENTS AS DIRECTED ABOVE Grant Deed#78904 EXHIBIT "A" , 20 and 21 of Block 201/as per map recorded in Book 19, Pages 33 and 34, in the Office of the County Recorder of said Riverside County. The Above legal description is pursuant to that Notice of Lot Merger recorded June 21, 1989 as Instrument No. 89- 205190 of official records. MAIN TAX CTATFhAFnITC nc n10CrrTCn ADnIM Exhibit "A" TWe Order Number. File Number: O-SA-2328gR Real property in the City of La Quinta, County of Riverside, State of California, described as follows: LOT 20 AND 21 OF BLOCK 201 SANTA CARMELITA AT VALE LA QUINTA UNIT #19, AS PER MAP — --RECORDED IN -BOOK -19 -.PAGE -33 AND. 34 OF MAPS,..I,N_TH._ EOFFL OF THE COUNTY RECORDER OF SAID RIVERSIDE COUNTY. -"- - THE ABOVE LEGAL DESCRIPTION IS PURSUANT TO THAT NOTICE OF LOT MERGER RECORDED JUNE 21, 1989 AS INSTRUMENT NO. 89-205190 OF OFFICIAL RECORDS. APN: 774-153-024-1 TITLE 24 REPORT Title 24 Report for: Perez Residence (Addition) It 53800 Avenida Rubio La Quinta, CA 92253 Project Designer: Santa Fe Builders 74-850 Joni Drive Palm Desert, CA 92260 (760) 674-84.50 Report Prepared By: CJ McFadden BREEZE AIR CONDITIONING 75-145 ST. CHARLES PLACE PALM DESERT, CA 92211 (760) 346-0855 CITY OF LA QUINTA BUILDING & SAFETY DEPT. APPROVED . FOR CONSTRUCTION DATE26110n8Y Job Number: Date: 10/17/2006 0 The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2005 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC - www.energysoft.com. EnergyPro 4.1 by EnergySoft Job Number. User Number. 3665 TABLE OF CONTENTS Cover Page Table of Contents Form CF -1 R Certificate of Complianc'e' Form MF -1 R Mandatory Measures Summary HVAC System Heating and Cooling Loads Summary Room Load Summary Room Heating Peak Loads Room Cooling Peak Loads Manufacturer's Specifications 1 I 1 2 3 7 9 10 11 -12 13 EnergyPro 4.1 by EnergySoR Job Number. User Number. 3665 Certificate Of Compliance:. Residential (Part 1 of 4) CF -1 R Perez Residame (Addition) 10/17/2006 Project Title Date _53$OD AvenidaRRi No I a Quinta --� Project Address Building Permit # _BREEZF AIR CONDITIONING, (760) 346-0855 Documentation Author Telephone plan Check/Date -C m pl -yPr Method Climate Zone Field Check/Date TDV Energy Use Standard Proposed Compliance (kBtu/sf-yr) Design Design Margin Space Heating 2.61 3.30 -0.69 Space Cooling 46.89 44.38 2.51 Fans 7.01 8.27 -1.26 Domestic Hot Water 0.00 0.00 0.00 Pumps 0.00 0.00 0.00 Totals 56.51 55.94 0.57 Percent better than Standard: 1.0% BUILDING COMPLIES - HERS VERIFICATION REQUIRED Building Type: Single Family FXI Addition Total Conditioned Floor Area: 524 ft2 ❑ Multi Family ❑ Existing + Add/Alt Existing Floor Area: r; n/a ft2 Building Front Orientation: (N) 0 deg Raised Floor Area: 0 ft2 Fuel Type: Natural Gas Slab on Grade Area: 524 ft2 Fenestration: Average Ceiling Height: 8.0 ft Area: 29 ft2 Avg. U: 0.77 Number of Dwelling Units: 0.35 Ratio: 5.5% Avg. SHGC: . 0.59 Number of Stories: 1 - BUILDING ZONE INFORMATION # of Thermostat Vent Zone Name Floor Area Volume Units Zone Type Type Hgt. Area HVAC -t1 52419192 n 5— Cpnditinnad Setback— 9_n1a OPAQUE SURFACES Insulation Act. Type Frame Area U -Fac. Cay. Cont. Azm. Tilt Rnof Wend 524 0 099 R-38 R_0.0 345 p _Wall Wood 172 0.102 R_13 R-0.0 _n AQ Door None 20 0 500 None R-0.0 x_90 Wall Wnnd 173 0089 R-21 R_0 0 An gp Wall Wnnd 170 0 O6q R_21 R -n n 180 go Wall Wood 37 0.069 _R_21 R-0.0 270 90 Door NnnP 20 0 S Nonp R-0 0 27n 9n Gains Condition Y / N Status i Run Initiation Time: 10/17/06 EnergyPro 4.1 by EnergySoft User Number. 3665 JA IV Reference Location / Comments 02-A11 70NF 01 09-A3 ZONE #1 28-A4 ZONE #1 09-A6 70NF 91 09-A6 ZONE #1 09-A6 ZONE #1 28-A4 70NE #1 Job Number: 1 3 of -13 I Certificate Of Compliance : Residential (Part 2 of 4) CF -1 R Perez Residence Project Title (_Addition) 10/17%2006 Date FENESTRATION SURFACES # Type Area U -Factor' True Cond. SHGC2 Azm. Tilt Stat. Glazing Type Location/ Comments J- Window Rear (S, 6.0 0.790 l l&A n �a 116-6 180 q0_ New Default nnu6le Metal 70NF_ #1 2 Window Rear (S) 3 Window Rear (S) 4 Window Right (W) 8.0 0.790 116-A 0_59 8.0 0.790 116-A 0_59 6.7 0.710 116-A 0_60 116-B 180 90 New Oft0QUffilftetal ZONE #1 116-B 180 90 New &DOARROMNletal ZONE #1 116-8 270 90 New etal Tinted (Fixed)ZONE #1 New ZONE #1 1. Indicate source either from NFRC or Table 116A. 2. Indicate source either from NFRC or Table 116B. INTERIOR AND EXTERIOR SHADING window Overhang Left Fin Right Fin # Exterior Shade Type SHGC Hgt. Wd. Len. Hgt. ' LExt. REA Dist. Len. Hgt. Dist. Len. Hgt. 1 Bug Screen 0.76 6.7 3.0 2.0 0.1 2.0 2.0 2 Bug Screen 0.76 4.0 2.0 2.0 0.1 2.0 2.0 3 Bug Screen 0.76 4.0 2.0 2.0 0.1 2.0 2.0 4 Bug Screen 0.76 6.7 1.0 0.0 0.0 0.0 0.0 THERMAL MASS FOR HIGH MASS DESIGN Area Thick.Heat Inside Condition Location/ Type (so (in.) Cap. Cond. R -Val. JA IV Reference Status Comments PERIMETER LOSSES Insulation Condition Location/ Type Length R -Val. Location JA IV Reference Status Comments Slab Perimeter 78 None No Insulation 26-A1 New ZONE #1 I EnergyPro 4.1 by EnergySoft • User Number. 3665 Job Number. Paoe:4 of 13 1 Certificate Of Compliance: Residential (Part 3 of 4) CF -1 R Perez Residence (Addition) 10/17/2006 Project Title Date HVAC SYSTEMS Heating Minimum Cooling Minimum Condition Thermostat Location Type Eff Type Eff Status Type HVAC -#1 Split Heat Pump 8.20 HSPF Split Heat Pump 15.2 SEER New Setback HVAC DISTRIBUTION Duct Heating Coolinq Location HVAC41 Ducted Ducted Attic Hydronic Piping Pipe . Pipe Insul. System Name Length Diameter Thick. Duct Condition Ducts R -Value Status Tested? 4:2 New Yes WATER HEATING SYSTEMS Rated Tank Energy Standbys Tank Insul. Water Heater # in Input Cap. Condition Fector Loss R -Value System Name Type Distribution Syst..(Btu/hr) (gal) Status or RE 1 (%) Ext. Multi -Family Central Water Heating Details Hot Water Pump Hot Water Piping Length (ft) Add 1/2" Control # HP Type In Plenum Outside Buried Insulation 1 For small gas storage (rated input <= 75000 Btu/hr), electric resistance and heat pump water heaters, list energy factor. For large gas storage water heaters (rated input > 75000 Btu/hr), list Rated Input, Recovery Efficiency and Standby Loss. For instantaneous gas water heaters, list Rated Input, and Recovery Efficiency. REMARKS COMPLIANCE STATEMENT This certificate of compliance lists the building features and specifications needed to comply with Title 24, Parts 1 and 6 of the California Code of Regulations, and the administrative regulations to implement them.This certificate has been.signed by the individual with overall design responsibility. The undersigned recognizes that compliance using duct design, duct sealing, verification of refrigerant charge and TXVs, insulation installation quality, and building envelope sealing require installer testing and certification and field verification by an approved HERS rater. Designer or Owner (per Business & Professions Code) Documentation Author Name: Name: CJ McFadden Title/Firm: Santa Fe Builders Title/Firm: BREEZE AIR CONDITIONING Address: 74-850 Joni Drive Address: 75-145 ST. CHARLES PLACE Palm Desert, CA 92260 PALM DESERT, CA 92211 Telephone: (760) 674-8450 Telephone: 760 346-0855 LIC. M e Q 11 (signature) (date) Enforcement Agency Name: Title/Firm: Address: Telephone: Certificate Of Compliance : Residential (Part 4 of 4) CF -1 R Perez Residence (Addition) 10/17/2006 • Project Title Date Special Features and Modeling Assumptions The local enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The local enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the aoequacy or ine spectai f usUTIcation ana aocumentation suomittea. IThe Roof "R-38 Roof" includes credit for a Radiant Barrier installed per Section 3.3.3 of the Residential Manual. Plan I Field HERS Required Verification Items in this section require field testing and/or verification by a certified home energy rater under the supervision of a CEC- approved HERS provider using CEC approved testing and/or verification methods and must be reported on the CF -0R Plan Field installation certificate. The HVAC System "HVAC -#1" incorporates HERS verified Duct Leakage. Target leakage is calculated and documented on the CF - 4R. The HVAC System "HVAC -#1" incorporates a HERS verified Refrigerant Charge test or a HERS verified Thermostatic Expansion Valve. The Cooling System "MAYTAG PSH4BF / PAH4VM (2 Ton)" includes credit for a 12.0 EER Condenser. A certified HERS rater must field verify the installation of the correct Condenser. I EnergyPro 4.1 by EnergySoft User Number. 3665 Job Number. Paae:6 of 13 1 4 Mandatory Measures Summary: Residential (Page 1 of 2) MF -1 R NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. More stringent compliance requirements from the Certificate of Compliance supercede the items marked with an asterisk (') below. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. DESCRIPTION Instructions: Check or initial applicable boxes when completed or check N/A if not ENFORCE - applicable. N/A DESIGNER MENT Building Envelope Measures § 150(a): Minimum R-19 in wood ceiling insulation or equivalent U -factor in metal frame ceiling. ❑ Q ❑ § 150(b): Loose fill insulation manufacturer's labeled R -Value: ❑ ❑ ❑ § 150(c): Minimum R-13 wall insulation in wood framed walls or equivalent U -factor in metal frame walls (does not ❑ ❑X ❑ apply to exterior mass walls). �§ 150(d): Minimum R-13 raised floor insulation in framed floors or equivalent U -factor. ❑ ❑ ❑ § 150(e): Installation of Fireplaces, Decorative Gas Appliances and Gas Logs. 1. Masonry and factory -built fireplaces have: ❑ I . ❑ a. closable metal or glass door covering the entire opening of the firebox ❑ ❑X ❑ b. outside air intake with damper and control, flue damper and control ❑ ❑X ❑ 2. No continuous burning gas pilot lights allowed. ❑ ❑X ❑ § 150(f): Air retarding wrap installed to comply witt§ 151 meets requirements specified in the ACM Residential Manual. ! ❑ ❑ ❑ § 150(g): Vapor barriers mandatory in Climate Zones 14 and 16 only. ❑ ❑ ❑ § 150(1): Slab edge insulation -water absorption rate for the insulation alone without facings no greater than 0.3%, water vapor ❑ ❑ ❑ . permeance rate no greater than 2.0 pemdinch. ❑ ❑ ❑ § 118: Insulation specified or installed meets insulation installation quality standards. Indicate type and❑ ❑ ❑ ❑ include CF -6R Forth: § 116-17: Fenestration Products, Exterior Doors, and Infiltration/Exfiltration Controls. ❑ ❑ ❑ 1. Doors and windows between conditioned and unconditioned spaces designed to limit air leakage. ❑ ❑X ❑ 2. Fenestration products (except field fabricated) have label with certified U -Factor, certified Solar Heat Gain Coefficient ❑ ❑X ❑ (SHGC), and infiltration certification. Page:7 of 13 3. Exterior doors and windows weatherstripped; all joints and penetrations caulked and sealed. ❑ Q ❑ 'Space Conditioning, Water Heating and Plumbing System Measures § 110-13: HVAC equipment, water healers, showerheads and faucets certified by the Energy Commission. ❑ Q ❑ § 150(h): Heating and/or cooling loads calculated in accordance with ASHRAE, SMACNA or ACCA. ❑ ❑ ❑ § 150(i):. Setback thermostat on all applicable heating and/or cooling systems. ❑ ❑X ❑ § 1500): Water system pipe and tank insulation and cooling systems line insulation. 1. Storage gas water heaters rated with an Energy Factor less than 0.58 must be externally wrapped with ❑ Q. ❑ insulation having an installed thermal resistance of R-12 or greater. w 2. Back-up tanks for solar systems, unfired storage tanks, or other indirect hot water tanks have R-12 external ❑ I . ❑ insulation or R-18 intemal insulation and indicated on the exterior of the tank showing the R -value. 3. The following piping is insulated according to Table 150-A/B or.Equation 150-A Insulation Thickness: 1. First 5 feet of hot and cold water pipes closest to water heater tank, non -recirculating systems, and entire ❑ Q' ❑ length of recirculating sections of hot water pipes shall be insulated to Table 150B. 2. Cooling system piping (suction, chilled water, or brine lines), piping insulated between heating source ❑ ❑X ❑ and indirect hot water tank shall be insulated to Table 150-B and Equation 150-A. 4. Steam hydronic heating systems or hot water systems > 15 psi, meet requirements of Table 123-A. ❑ ❑ ❑ 5. Insulation must be protected from damage, including that due to sunlight, moisture, equipment ❑ Q ❑ maintenance, and wind. 6. Insulation for chilled water piping and refrigerant suction piping includes a vapor retardant or is enclosed ❑ ❑ ❑ entirely in conditioned space. 7. Solar water -heating systeiTWcollectors are certified by the Solar Rating and Certification Corporation. ❑ ❑ ❑ EnergyPro 4.1 by EnergySoft User Number. 3665 Job Number. Page:7 of 13 Mandatory Measures Summary: Residential (Page 2 of 2) MF -1 R NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. More stringent compliance requirements from the Certificate of Compliance supercede the items marked with an asterisk (') below. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. DESCRIPTION Instructions: Check or initial applicable boxes when completed or check N/A if not ENFORCE - applicable. N/A DESIGNER MENT Space Conditioning, Water Heating and Plumbing System Measures: (continued) § 150(m): Ducts and Fans 1. All ducts and plenums installed, sealed and insulated to meet the requirements of the CMC Sections 601, 602, 603, 604, ❑. 0 ❑ 605, and Standard 6-5; supply -air and retum-air ducts and plenums are insulated to a minumum installed level of R-4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct -closure system that meets the applicable requirements of UL 181, UL 181A, or UL 181B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings greater than 1/4 inch, the combination of mastic and either mesh or tape shall be used. 2. Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than ❑ 0 ❑ sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and ❑ ❑ ❑ § 115: Gas fired fan -type central furnaces, pool heaters, spa heaters or household cooking appliances have no continuously ❑ ® ❑ support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause § 118 (1): Cool Roof material'meets specified criteria ❑ ❑ ❑ reductions in the cross-sectional area of the ducts. § 150(k)l: HIGH EFFICACY LUMINAIRES OTHER THAN OUTDOOR HID: contain only high efficacy lamps as outlined in Table ❑ ® ❑ 3. Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive ❑ ® ❑ duct tapes unless such tape is used in combination with mastic and draw bands. ❑ ❑X ❑ luminaire has factory installed HID ballast. 4. Exhaust fan systems have back draft or automatic dampers. ❑ ® ❑ 5. Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operat fg ❑ ® ❑ dampers. , § 150(k)4: Permanently installed luminaires located other than In kichens, bathrooms,garages, laundry rooms, and utility rooms shall be high efficacy luminaires (except closets less than 70 ft) OR are controlled by a dimmer switch OR are ❑ © ❑ 6. Protection of Insulation. Insulation shall be protected from damage, including that due to sunlight, moisture, equipment ❑ ® ❑ maintenance, and wind. Cellular foam insulation shall be protected as above or painted with a coating that is water § 150(k)6: Luminaires providing outdoor lighting and permanently mounted to a residential building or to other buildings on the ❑ © ❑ retardant and provides shielding from solar radiation that can cause degradation of the material. 680 locations) OR are controlled by occupant sensors with integral photo control certified to comply with Section 119(d). 7. Flexible ducts cannot have porous inner cores. ❑ ❑ ❑ § 114: Pool and Spa Heating Systems and Equipment 1. A thermal efficiency that complies with the Appliance Efficiency Regulations, on-off switch mounted outside of the ❑ ❑ ❑ heater, weatherproof operating instructions, no electric resistance heating and no pilot light. 2. System is installed with: a. At least 36' of pipe between filter and heater for future solar heating. ❑ ❑ ❑ b. Cover for outdoor pools or outdoor spas. ❑ ❑ . ❑ 3. Pool.system has directional inlets and a circulation pump time switch. ❑ ❑ ❑ § 115: Gas fired fan -type central furnaces, pool heaters, spa heaters or household cooking appliances have no continuously ❑ ® ❑ burning pilot light. (Exception: Non -electrical cooking appliances with pilot < 150 Btu/hr) § 118 (1): Cool Roof material'meets specified criteria ❑ ❑ ❑ Lighting Measures § 150(k)l: HIGH EFFICACY LUMINAIRES OTHER THAN OUTDOOR HID: contain only high efficacy lamps as outlined in Table ❑ ® ❑ 150-0, and do not contain a medium screw base socket (E24/E26). Ballasts for lamps 13 Watts or greater are electric and have an output frequency no less than 20 kHz. § 150(k)1: HIGH EFFICACY LUMINAIRES - OUTDOOR HID: contain only high efficacy lamps as outlined in Table 150-0, ❑ ❑X ❑ luminaire has factory installed HID ballast. § 150(k)2: Permanently installed luminaires in kitchens shall be high efficacy luminaires. Up to 50% of the Wattage, as determined ❑ 2 ❑ in Section 130(c),gf permanently installed luminaires in kitchens may be in luminaires that are not high efficacy luminaires, provided that these luminaires are controlled by switches separate from those controlling the high efficacy luminaires. § 150(k)3: Permanently installed luminaires in* bathrooms, garages, laundry rooms, utility rooms shall be high efficacy luminaires. ❑ ❑X ❑' OR are controlled by an occupant sensor(s) certified to comply with Section 119(d). , § 150(k)4: Permanently installed luminaires located other than In kichens, bathrooms,garages, laundry rooms, and utility rooms shall be high efficacy luminaires (except closets less than 70 ft) OR are controlled by a dimmer switch OR are ❑ © ❑ controlled by an occupant sensor that complies with Section 1=19(d) that does not tum on automatically or have an always on option. § 150(k)5: Luminaires that are recessed into insulated ceilings are approved for zero clearance insulation cover (IC) and are ❑ ❑A ❑ certified to ASTM E283 and labeled as air tight (AT) to less than .2.0 CFM at 75 Pascals. § 150(k)6: Luminaires providing outdoor lighting and permanently mounted to a residential building or to other buildings on the ❑ © ❑ same lot shall be high efficacy luminaires (not including lighting around swimming pools/Water features or other Article 680 locations) OR are controlled by occupant sensors with integral photo control certified to comply with Section 119(d). § 150(k)7: Lighting for parking lots for 8 or more vehicles shall have lighting that complies with Sections 130, 132, and 147. ❑ ❑ ❑ Lighting for parking garages for 8 or more vehicles shall have lighting that complies with Section 130, 131, and 146. § 150(k)8: Permanently installed lighting in the enclosed, non -dwelling spaces of low-rise residential buildings with four or more ❑ ❑ ❑ dwelling units shall be high efficacy luminaires OR are controlled by occupant sensor(s) certified to comply with Section 119(d). EnergyPro4.1 by EnergySoft User Number. 3665 Job Number. Page:8 of. 13 t. , 0 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME DATE Perez Residence Addition 10/17/2006 SYSTEM NAME FLOOR AREA HVAC -#1 524 Number of Systems 1 1 Heating System Output, per System 25;000 Total Output (Btuh) 25,000 Output (Btuh/sgft) 47.7 Cooling System Output per System 24,000 Total Output (Btuh) 24,000 Total Output (Tons) 2.0 Total Output (Btuh/sgft) 45.8 Total Output (sgft/Ton) 262.0 Air System CFM per System 800 Airflow (cfm) 800 Airflow (cfm/sgft) 1.53 Airflow (cfm/Ton) 400.0 Outside Air (%) 4.9 Outside Air (cfm/sgft) 0.07 ote: values above given at ARI conditions :ATING SYSTEM PSYCHROMETRICS 26.0 of 67.1oF Outside Air 39 cfrn 69.2 of COOLING SYSTEM 111.0 / 77.6 of Outside Air 39 cfm 73.0/59.6 of j EnergyPro 4.1 Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAK 1iCOILHTG.PEAK CFM I Sensiblel Latent I I CFM I Sensible 378 7192 1,69 570 8,870 0 821 678 0 0 39 1,590 947 39 1,807 0 0 821 678 11,154 2,640 12 032 MAYTAG PSH4BF / PAH4VM (2 Ton) 20,005 0 15,614 Total Adjusted System Output 20,005 0 15,614 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK Aug 2 pm i Jan 12 am Cream Temperatures at Time of Heating Peak) 85.4 of 85.4 of Heating Coil t'�L.,. Supply Air Ducts Supply Fan 84.6 of 800 cfm ROOMS 70.0 of Return Air Ducts I irstream Temperatures at Time of Cooling Peak) 74.8 / 60.7 of 51.3 / 50.2 of 51.3 / 50.2 of ;'FIF 4Supply Air Ducts Cooling Coil Supply Fan 52.3 / 50.7 of 800 cfm47.0% R.H. ROOMS 72.0 / 59.2 of User Number. 3665 Return Air Ducts Job Number. of 13 ROOM LOAD SUMMARY I PROJECT NAME Perez Residence Addition DATE 10/17/2006 SYSTEM NAME HVAC -#1 FLOOR AREA 524 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK ZONE NAME ROOM NAME Mult. CFM SENSIBLE LATENT CFM SENSIBLE LATENT CFM SENSIBLE ZONE #1 HVAC -#1 1 378 7,921 1,692 378 7,921 1,692 570 8,870 w PAGE TOTAL TOTAL 1 378 7,921 1,692 570 8,870 1 378 7,921 1,692 570 8,870 EnergyPro By EnergySoft User Number. User Job Number. Page: 10 of 13 . • i ROOM HEATING PEAK LOADS Project Title Date Perez Residence Addition 10/17/2006 Room Information Desi n Conditions Room Name HVAC -#1 Time of Peak Jan 12 am Floor Area 524 Outdoor Dry Bulb TemPerature 26°F Indoor Dry Bulb Temperature 70°F Conduction Area U -Value AT OF: Btu/hr Items shown with an asterisk (•rr) denote conduction through an interior surface to another room. Page Total: 6941 Infiltration: �i 1.001 x 1.064 x 524 x 8.00 x 0.589 / 60] x 0 = 1 929 chedule Alr Sensible Area Ceiling Height ACH OT Fraction TOTAL HOURLY HEAT LOSS FOR ROOM 8.870 EnergyPro 4.1 by EnergySoft User Number. 3665 Job Number. Page: 11 of 13 i 524.0 x x X X x x X x X x X X x x x x x x x x x x x x. x x x x x x x x x x x x x X x 0.0290 x x x x x X x X X X X x x x x x x x x x x x x x x x x x x x x x x x x x x x x 44 — = = = = = = = =. = = = = = = = = = = = = = = = = = = = = = = = = = = = 669 172.0 0.1020 44 772 20.0 0.5000 44 440 172.8 0.0690 44 525 170.0 0.0690 44 516 6.0 0.7900 44 209 8.0 0.7900 44 278 8.0 0.7900 44 278 7 0,0690 44 113 6.7 0.7100 209 20.0 0.5000 44=440 perimeter = 77.6 0.7300 f 44 2,493 Items shown with an asterisk (•rr) denote conduction through an interior surface to another room. Page Total: 6941 Infiltration: �i 1.001 x 1.064 x 524 x 8.00 x 0.589 / 60] x 0 = 1 929 chedule Alr Sensible Area Ceiling Height ACH OT Fraction TOTAL HOURLY HEAT LOSS FOR ROOM 8.870 EnergyPro 4.1 by EnergySoft User Number. 3665 Job Number. Page: 11 of 13 i RESIDENTIAL ROOM COOLING. LOAD SUMMARY upaque surfaces R-38 Roof R-13 Wall Solid Wood Door R-21 Wall R-21 Wall R-21 Wall Solid Wood Door Orientation Area X X X X X X x X X x XX x U -Factor X X X X X X x X X x X CLTD 1 N 524.0 0.0201 56.0 N 172.0 0.1020 23.0 N 20.0 0.5000 23.0 E 172.8 0.0690 33.0 S 170.0 0.0690 26.0 W 37.3 0.0690 33.0 (W) 20.0 0.5000 33.0 Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Fenestration rage I otai Orientation Shaded Area .x x x X x X X X GLF + + + + + + + + Unshaded Area X x X X X X X X GLF S 6.0X 37.7+ 0.0x 37.8 S 8.0X 37.7+ 0.0X 37.8 S 8.0 37.7 0.0 37.8 W 0.0x 36.5+ 6.7X 72. Page Total Btu/hr - 589 404 230 393 305 85 330 2 336 Btu/hr Internal Gain Btu/hr Occu ants DX X Occupants x 230 BtUh/occ. = 920 E ui ment' Dwelling Units X 1,6001 Wafts/sqft = 1 600 w Infiltration: 1.064 x 124 x 33.20 x = 1.7531 Air Sensible CFM ELA OT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 7,6211 Latent Gain Btu/hr Occu ants ® x Occupants X 200 Btuh/occ. = 800 Infiltration: 4 77 x 1.24 ' x 33.20 x 0.00454 = 892 Air Latent CFM ELA pW TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 1,692 EnergyPro 4.1 by EnergySoft User Number. 3665 Job Number. Page: 12 of 13