11245 (SFD)Tihf 4 4 Qxk&
Z(010 P.O. BOX 1504
Building 54- Rubio 78-105 CALLE ESTADO
AfirtrPsc LA QUINTA, CALIFORNIA 92253
Development Corp.
Mailing
Address 74940 Hwy 111
City Zip Tel.
Indian Wells 92216 564--6329
Contractor
Synercon Dev.
Address
same
Zip
State Lic. City
& Classif. B 337440 Lic. # 2279
Designer
Address Tel.
CityI Zip I State
Lic. #
LICENSED CONTRACTOR'S DECLARATION
I hereby affirm that 1 am licensed under provisions of Chapter 9 (commencing with Section
7000) of!Division 3 of the; Business And Professions Code; and my license is in full force and
effect.
- � r�`.:���-s.�..�.-�°kf i� CSC-'zr�c-.•-L�._.
GNATURE DATE
OWNER -BUILDER DECLARATION
I hereby affirm that I am exempt from the Contractors License Law for the following
reason: (Sec. 7031.5,Business and Professions Code: Any city or county which requires a
permit to construct, after, improve, demolish, or repair any structure, prior to its issuance also
requires the applicant for such permit to rile a signed statement that he is licensed pursuant to
the provisions of the Contractor's License Law, Chapter 9 (commencing with Section 7000) of
Division 3 of the Business and Professions Code, or that. he is exempt therefrom, and the basis
for the alleged exemption. Any violation of Section 7031.5 by 'any applicant for a permit
subjects the applicant to a ciw7 penalty of not more than rive hundred dollars ($500).
❑ I, as owner of the property, or my employees with wages as their sole compensation, will
do the work, and the structure is not intended or offered for sale. (Sec. 7044, Buisness and
Professions Code: The Contractor's License Law does not apply to an owner of property who
builds or improves thereon and who does such work himself or through his own employees,
provided that such improvements are not intended or offered for sale. If, however, the building
or improvement is sold within one year of completion, the owner -builder will have the burden
of proving that he did not build or enprove for the purpose of sale.)
O I, as owner of the property, am exclusively contracting with licensed contractors to con-
struct the project. (Sec. 7044, Business and Professions Code: The Contractoi's License Law
does not apply to an owner of property who builds or improves thereon, and who contracts for
such projects with a contractor(s) licensed pursuant to the Contractor's License Law.)
❑ 1 am exempt under Sec B. & P.C. for this reason
Date Owner
WORKERS' COMPENSATION DECLARATION
I hereby affirm that I have a certificate of consent to self -insure, or a certificate of
Worker's Compensation Insurance, or a certified copy thereof. (Sec. 3800, Labor Code.)
Policy No. Company
l7 Copy is filed with the city. ❑ Certified copy is hereby furnished.
CERTIFICATE OF EXEMPTION FROM
WORKERS' COMPENSATION INSURANCE
(This section need not be completed if the permit is for one hundred dollars ($100) valuation
or less.) - '
I certify that In the performance of the work for which this permit is issued, I shall not
=any Person in any manner so as to become subject to the Workers' Compensation
Laws of California
Date Owner
NOTICE TO APPLICANT: If, after making this Certificate of Exemption you should become
subject to the Workers' Compensation provisions of the Labor Code, you must forthwith
comply with such provisions or this permit shall be deemed revoked.
CONSTRUCTION LENDING AGENCY
I hereby affirm that there is a construction lending agency for the performance of the
work for which this permit is issued. (Sec. 3097, Civil Code.)
Lender's Name
Lender's Address
This is a building permit when properly filled out, signed and validated, and is subject to
expiration if work thereunder is suspended for 180 days.
I certify that I have read this application and stale that the above information is correct.
I agree to comply with all city and county ordinances and state laws relating to building
construction, and hereby authorize representatives -of this city to enter the above-.
mentioned property for inspection purposes.
Signature of applicant Date
Mailing Address
City, State, Zip
No. 11245
BUILDING: TYPE CONST. OCC: GRP.:
Number
Legal Description Lot 24 Block 264
Project Description
Sq. Ft. 1778
Size
No. No. Dw.
Stories Units
New ❑ Add ❑
Alter ❑ Repair ❑ Demolition ❑
Permit does
nbbtinclude block wall or
pool
m
Estimated Valuation
142 129.40
PERMIT
AMOUNT
Plan Chk. Dep.
250.00
Plan Chk. Bal.
294.06
Const.
652.00
Mech.
42.50
Electrical
133.73
Plumbing
141.00
S.M.I.
10.30
Grading
20 .OEC
Driveway Enc.
.00
Infrastructure
2239.6b
Arts in Public 25.00
TOTAL
t3�26t:�5., tU tatJ.1CJ`:'J
REMARKS
ZONE: BY:
Minimum Setback Distances:
Front Setback from Center Line
Rear Setback from Rear Prop. Line
Side Street Setback from Center Line
Side Setback from Property Line
FINAL DATE INSPECTOR
Issued by: Date Permit
Validated by:
Validation:
CONSTRUCTION ESTIMATE
NO. ELECTRICAL FEES
NO. PLUMBING FEES
1ST FL. SQ. FT. ® $
2ND FL. SQ. FT. ®
POR. SQ. FT. ®
GAR. SO. FT. ®
CAR P. SQ. FT.
WALL SQ. FT. ®
SQ FT ®
ESTIMATED CONSTRUCTION VALUATION $
UNITS
MOBILEHOME SVC.
POWER OUTLET
YARD SPKLR SYSTEM `
BAR SINK
ROOF DRAINS
DRAINAGE PIPING
DRINKING FOUNTAIN.
URINAL
WATER PIPING
NOTE: Not to be used as property tax valuation
SLAB GRADE
FLOOR DRAIN
MECHANICAL FEES
WATER SOFTENER
VENT SYSTEM FAN EVAP.COOL HOOD
SIGN
WASHER(AUTO)(DISH)
APPLIANCE DRYER
SEWER OR SEPTIC TANK
GARBAGE DISPOSAL
FURNACE UNIT WALL FLOOR SUSPENDED
DUCT WORK
LAUNDRY TRAY
AIR HANDLING UNIT CFM
KITCHEN SINK
ABSORPTION SYSTEM B.T.U.
TEMP USE PERMIT SVC
WATER CLOSET'
COMPRESSOR HP
POLE,TEM/PERM
LAVATORY
HEATING SYSTEM FORCED GRAVITY
AMPERES SERV ENT
SHOWER
BOILER. B.T.U.
SQ. FT. ® c
BATH TUB
SO. FT. ®c
WATER HEATER
MAX. HEATER OUTPUT, B.T.U.
SQ. FT. RESID ® 1+/. c
SEWAGE DISPOSAL
BOND BEAM
SQ.FT.GAR ® Vbc
HOUSE SEWER
GAS PIPING
PERMIT FEE
PERMIT FEE
PERMIT FEE
DBL
TOTAL FEES
MICRO FEE
MECH.FEE PL.CK.FEE
CONST. FEE ELECT. FEE
SMI FEE PLUMB. FEE
STRUCTURE 7 PLUMBING ELECTRICAL HEATING & AIR COND. SOLAR
'T7 .
SETBACK
GROUND PLUMBING '713VVO,
tg
UNDERGROUND
A.C. UNIT
COLL. AREA
SLAB GRADE
ROUGH PLUMB.
BONDING
HEATING (ROUGH)
STORAGE TANK
FORMS
SEWER OR SEPTIC TANK
ROUGH WIRING.
DUCT WORK
ROCK STORAGE
FOUND. REINF.
GAS (ROUGH)
METER LOOP
HEATING (FINAL)
OTHER APP.IEQUIP.
REINF. STEEL
GAS (FINAL)
TEMP. POLE l V,4
UUU ✓
GROUT
WATER HEATER
SERVICE
FINAL INSP.
BOND BEAM
WATER SYSTEM
GRADING
cu. yd.
$ plus x$
=$
LUMBER GR.
FINAL INSP./O Q
FRAMING 2
a%� Lo
V-`
FINAL INSP. a
!�
ROOFING � (
� � pt� L'^
REMARKS:
VENTILATION
FIRE ZONE ROOFING:
FIREPLACE
SPARK ARRESTOR
A��R..FIIREWALL
G(��
MESH
INSULATION/SOUND 2
FINISH GRADING
FINAL INSPECTION-/jw
CERT. OCC.
FENCE FINAL
INSPECTOR'S SIGNATURESIINITIALS
GARDEN WALL FINAL
/-
DESERT SANDS UNIFIED SCHOOL DISTRICT
82-879 Highway 111
NOTICE: Indio, CA 92201
Document Cannot Be Duplicated (619) 347-8631
Date 7/28/92
No. 111601
Owner Name
Type of Permit
Synercon Development Corporation
No. 54340 street Rubio
City La Quinta zip 92253
La Quinta
Permit #
Log #
Study Area 110
APN # Tract # Lot # Square Footage 11825
Type of Development I Single Family Residence No. of units
Comments
At the present time, the Desert Sands Unified School District does not collect fees on
garages/carports, covered patios/walkways, residential additions under 500 square feet,
detached accessory structures or replacement mobilehomes. It has been determined
the above-named owner is exempt from paying school fees at this time due to the
following reason:
EXEMPTION NOT APPLICABLE
This certifies that school facility fees imposed pursuant to Government Code 53080
in the amount of 11.58 1 X 11.825 or $ 2,883.50 have been paid to D.S.0 S.D. for
the property listed above and that building permits and/or Certificates of Occupancy for
this square footage in this proposed project may now be issued.
Fees Paid By Synercon Development Telephone 564-6929
Name on the check
By James E. Lively
Assistant Superintendent, Business Services
Fee collected /exempted by Vickie J. Durrettq Jr
Payment -Rece ved,
f
Signature C?ieck No. 100
Collector: Attach a copy of county or city plan check application form to district copy for all waivers.
Embossed Original- Building Dept./Applicant Copy - Applicant/Receipt Copy- Accounting r k
f
VjNi
CALVIN C. KAMINSKAS
Assistant Commissioner
(714) 275.3000
OFFICE OF
AGRICULTURAL COMMISSIONER
JAMES O. WALLACE, Commissioner
83-612 Avenue 45 Suite 7
Indio, CA 92201
(619) 342-8291
DAN RILEY
Sealer. Weights & Measures
(114)215-3030
DATE 7, �J-. CASE NO. Q C Cts ? 213 92 -
r.-3DEVELOPER'S NAME: L
ADDRESS:
-r=Lj n i_rtM IAj
C_ -Lr
TELEPHONE:
3 (710
Dear Developer:
After reviewing your landscaping plans, all plant material listed is riot in
violation of quarantine laws governing Lhe Coachella Valley. if substitutions
do occur and they differ from plant materia]_ listed, this office must be notified
irmtediately. .
Thank you for protecting and preserving the Coachella Valley's pest -free ertvi.ronment.
Agricult C ssioner's Office
L11
cc: Indio and Riverside
4080 LEMON STREET, ROOM 19, RIVERSIDE, CALIFORNIA 92501 - FAX (714) 275-3012
0
'W,
V.
4080 LEMON STREET, ROOM 19, RIVERSIDE, CALIFORNIA 92501 - FAX (714) 275-3012
0
00r -751T." OF 115
EARTH SYSTEMS CONSULTANTS S.C.
BUENA ENGINEERS DIV.
79-811B Country Club Drive
Bermuda Dunes, CA 92201 9 (619) 345-1588
Client,
Client Address
Client Phone
DATE
3o i
JOB NO.
P7 -yo
P/
FIELD TESTING
-'LOCATION
Z_
MOISTURE
DRY
CONTRACTOR,
5,1piercz-'-,7 tL,,,,e/
OWNER
I
OPTIMUM
WEATHER
"c
TEMP.
0 at
0 at
AM
PM
PRESENT AT SITE
NO.
ELEVATION
CONTENT
DENSITY
DRY
DRY
MOISTURE
CLIENT REPRESENTATIVE SIGNATURE
FIELD REPORT
TECHNICIANS SIGNATURE
FIELD TESTING
-REFERENCE CURVE
MOISTURE
DRY
MAXIMUM
MAXIMUM
OPTIMUM
TEST
JEST LOCATION
LOT
NUMBER
NO.
ELEVATION
CONTENT
DENSITY
DRY
DRY
MOISTURE
%
lbs./Cu. ft.
0 DENSITY
DENSITY
CONTENT
%
s lbs./cu. ft.
%
per P/;'."
115. q
REMARKS:
'411 0 >
CLIENT REPRESENTATIVE SIGNATURE
FIELD REPORT
TECHNICIANS SIGNATURE
TITLE 24 REPORT FOR:
SINGLE FAMILY DWELLING
54-340 RUBIO
LA QUINTA; CA. 92210
PROJECT DESIGNER: --
SYNERCON DEVELOPEMENT CORP.
74-940 HWY. 111 SUITE 429
INDIAN WELLS, CA. 92210
OWNER:
SYNERCON DEVELOPEMENT CORP.
74-940 HWY. 111 SUITE 429
INDIAN WELLS, CA. 92210
REPORT PREPARED BY:
R&R ENGINEERING AND CONSTRUCTION -SVS.
R.E. THOMPSON
55857 29 -PALMS HWY., YUCCA VALLEY, CA.
(619) 369-7486.
Job Number: SYN1778N
Date: 7/22/1992
The COMPLY 24 computer program has been used to perform the calculations
summarized in -this compliance report. This pro7ram has interim approval
and is authorized by the California Energy Commission for use with the
Second Generation Nonresidential Building Energy Efficiency Standards
for Nonresidential OccuVancies. Second Generation Residential Occupancies
shown to comply with this program conform to the results produced by the
Public Domain Point System, developed by the California Energy Commission.
This program developed by Gabel Dodd Associates (415) 428-0803.
,, 1
Table Of Contents for Title 24 Report
------------------------------------
Cover Page ............................................. ....... ::. 1
Table of _Contents ................................................... 2
Form CF -1R Certificate of Compliance: Residential 3
Form MF -1R Mandatory Measures Checklist: Residential 6
Form P -2R Point System Summary ...................................... 8
Form S Shading Coefficient (SC) Worksheet ........................... 9
Domestic Hot Water, Worksheet ........................................ 11
Form WS -1R Points Thermal Mass Worksheet 12
Form WS -2R Interpolation Worksheet .................................. 13
Form CF -3 Construction Assemblies 14
HVAC Zone & Space Loads Summary ...................................... 22
/I
CERTIFICATE OF
---------------------------------------------------------------------------
COMPLIANCE:.Residential (part 1 of 3)
CF -IR page
3 of 24
Project: SINGLE
FAMILY DWELLING
360
I COMPLY 24
v 3.20
Designer: SYNERCON DEVELOPEMENT-CORP.
Location: Indio Date: 7/22/i992
Documentation: R&R ENGINEERING AND CONSTRUCTION SVS.
PROJECT ADDRESS
54-340 RUBIO
LA QUINTA, CA. 92210
GENERAL INFORMATION
Compliance Method:.
Climate Zone:
Total Conditioned Floor Area:
Building Occupancy:
Front Entry Orientation:.
Number of Dwelling Units:
Floor Construction Type:
Infiltration Control:
BUILDING SHELL INSULATION
Job #: SYN1778N
Point System
15
1778 sgft
Single Fam Det
North
1
Slab
Standard
Building Permit No
Checked By
Date User # 1615
--------------------
Component ..Area U -Value Location/Comments
R-13 Frame/Power Wall
1504
0.0520
WHOLE
HOUSE
R-13 Frame Wall
360
0.0853
WHOLE
HOUSE
R-38 Roof/Gyp Ceiling
1778
0.0288
WHOLE
HOUSE
Carpeted Slab
1453
0:7200
WHOLE
HOUSE/Insul= R-0.0
Exposed Slab
225
0:9000
WHOLE
HOUSE/Insul= R-0.0
Exposed Slab
50
0.5500.
WHOLE
HOUSE/Insul= R-7.0
Carpeted Slab
100
0.5000
WHOLE
HOUSE/Insul= R-7.0
THERMAL MASS
Thick
Mass Material
--------------- - - - - --
Area
- - --
(in).
- - - ---
Type
-
Location/Description
Concrete, Heavyweight
1553 .3.500
Covered
- - - --
------------------------------
WHOLE HOUSE/Int Mass
Concrete, Heavyweight
225
3.500 Exposed
WHOLE HOUSE/Int Mass
CERTIFICATE OF COMPLIANCE: Residential.(part 2 of 3) CF -1R page 4 of 24
------------
Project: SINGLE-FAMILY DWELLING COMPLY 24 v 3.20
Designer: SYNERCON DEVELOPEMENT CORP.. Building Permit No
Location: Indio Date: 7/22/1992 CRe-cZe-21 By
Documentation: R&R ENGINEERING AND CONSTRUCTION SVS. Date User # 1615
GLAZING Glass w/Int
Location Orient Area Type U -Val. SC Shade Description
--------------- - -
WHOLE HOUSE
North 76.0 Double 0.65 0:57 0.57 Double Solar Bronze
North 20.0 Double 0.65 0:57 0.57 Double Solar Bronze
South 46.0 Double 0.65 0.57 0:57 Double Solar Bronze
West 12.0. Double 0.65 0.57 0.57 Double Solar Bronze
West 20.0 Double 0.65 0.57 0.57 Double Solar Bronze
East 22.0 Double 0.65 0.57 0.57 Double Solar Bronze
SHADING (for Glazing above) Over
Location Exterior Device SC hang Framing Type
--------- ------------------------ ---- ---- -----------------------
WHOLE HOUSE
50 % Bug Screen 0.84 0.0 Metal w/Mullions
None 1.00 0.0 Wood Door w/Mullions
50 % Bug Screen 0.84 0.0 Metal w/Mullions
50•% Bug Screen 0.84 0.0 Metal w/Mullions
None 1:00 0.0 Wood Door w/Mullions
50 % Bug Screen 0.84 0.0 Metal w/Mullions
CERTIFICATE OF COMPLIANCE: Residential (part 3 of 3) CF -1R page 5 of 24
------------------------------- ---------------------------------------------
Project: SINGLE FAMILY DWELLING I COMPLY 24 v 3.20
Designer: SYNERCON DEVELOPEMENT CORP.
Location: Indio Date: 7/22/1992
Bui ing Permit No
Checked By
Documentation: R&R ENGINEERING AND CONSTRUCTION SVS. I Date User # 1615
-------------------------------------------------- ------------------------
HVAC SYSTEMS Minimum Output Duct Duct Manufacturer/Model No.
System Type'Efficiency (Btuh) Location RVal (or approved equal)
----------- ------- -- ---------------------- ---- -----------------------
Heat Pump 6.600 HSPF 66100 Vent. Attic Space 5.6 RHEEM RPND048J HT.PUMP
Air Cond 9.500 SEER 47500 Vent: Attic Space
Zone Furnace Max: 1.3 x [ 29893 Btuh + (10 x 1778 sqft)] = 61975 Btuh
Cooling Exception: CFM Cooling (see Load Calcs) requires Btuh
HOT WATER SYSTEMS Tank Manufacturer/Model No. # of Enemy R-12
System Type Volume (or approved equal) Sys Credits Blanket
-- - - - - - - - - - - - -- - -- - -- - ------------------- - -- --- -- - --- - - - - --- - - - - - -
Electric Resistance 47.0 A.O..Smith DSE-050 (SE) 1 0 Y
SPECIAL FEATURES/REMARKS (Add extra sheets if necessary)
COMPLIANCE STATEMENT
This Certificate of Compliance lists the building features and performance
specifications needed to comply with Title.24, Chapter 2-53 and Title 20,
Chapter 2, Subchapter 4, Article 1'of the California Administrative Code.
This certificate has been signed by the individual with overall design
responsibility and the building owner, who shall retain a copy of it and
transmit the certificate_to any subsequent purchaser of the building. When
this Certificate of Compliance is submitted for a single building plan to
be built in multiple orientations; all building conservation features which
vary are indicated in the Special Features/Remarks section.
DESIGNER I
SYNERCON DEVELOPEMENT CORP.
74-940 HWY. 111 SUITE 429
INDIAN WELLS, CA. 92210
License No:
Signed
ate
DOCUMENTATION AUTHOR
R&R ENGINEERING AND CONSTRUCTION SVS.
R.E. THOMPSON
55857 29 -PALMS HWY., YUCCA VALLEY; CA.
(619) 369-7486
BUILDING OWNER
SYNERCON DEVELOPEMENT CORP.
74-940 HWY. 111 SUITE 429
INDIAN WELLS, CA. 92210
Signed: AL
Date
ENFORCEMENT
Name:
Agency:
Telephone:_
AGENCY
s'
Signed: ����, '?�22/9Z— Signed:
at Date
MANDATORY MEASURES CHECKLIST (part 1 of,2) MF -1R page 6 of 24
---------------------------------------------------------'---------=--------
Project: SINGLE FAMILY DWELLING
COMPLY 24 v 3.20
Designer: SYNERCON DEVELOPEMENT CORP.
Location: Indio Date: 7/22/1992
Building Permit No
Checked By
Documentation: R&R ENGINEERING AND CONSTRUCTION SVS. I Date User # 1615
---------------------------------------------------------------------------
NOTE: Lowrise residential buildings subject to the Standards must contain
these measures regardless of the compliance approach used. Items._cmarked
with-an'asterisk (*) may be superseded by more stringent compliane
requirements listed on the Certificate of Compliance. When this checklist
is incorporated into the permit documents, the features noted shall be
considered by all parties as binding minimum component performance
specifications for the mandatory measures whether they are shown elsewhere
in the documents or on this checklist only.
BUILDING ENVELOPE MEASURES
o Sec. 2-5352(a): Minimum ceiling insulation R-19
weighted average. *
o Sec. 2-5352(b): Loose fill insulation manufacturers
labeled R -.Value.
o Sec. 2-5352(c): Minimum wall insulation in framed walls R-11
weighted average (does not apply to exterior mass walls).
o Sec. 2-5352(k): Slab edge.insulation - water absorption rate
,no greater than 0.3t, water vapor transmission rate no
greater than 2.0 perm/inch.
o Sec. 2-5311: Insulation specified or installed meets
California Energy Commission (CEC) quality standards.
Indicate type and form.
o Sec. 2-5352(f): Vapor barriers mandatory in Climate Zones 14
and 16 only.
o Sec. 2-5317: Infiltration/Exfiltration Controls
a. Doors and windows between conditioned and unconditioned
spaces designed to limit air leakage.
b. Doors and windows certified.
c. Doors and windows weatherstripped;• all joints and
penetrations caulked and sealed.
o Sec. 2-5352(e): Special infiltration barrier installed to
comply with Sec. 2-5351 meets CEC quality standards.
o Sec. 2-5352(d): Installation of Fireplaces
1. Masonry and factory -built fireplaces have:
a. Tight fitting, closeable metal or glass door
b. Outside air intake with damper and control
c. Flue damper and control
2. No continuous burning gas pilots allowed.
Enforcement
MANDATORY MEASURES CHECKLIST (part 2 of 2) MF -1R page 7 of 24
---------------------------------------------------------------------------
Project: SINGLE FAMILY DWELLING I COMPLY 24 v 3.20
Designer: SYNERCON DEVELOPEMENT CORP.
Location: Indio Date:.7/22/1992
Building Permit No
Checked By
Documentation: R&R ENGINEERING AND CONSTRUCTION SVS. I Date User # 1615
---------------------------------------------------------------------------
HVAC AND PLUMBING SYSTEM MEASURES
o Sec. 2-5352(g).and 2-5303: Space conditioning equipment
sizing: attach calculations.
o Sec. 2-5352(h) and 2-5315: Setback thermostat on all
applicable heating systems.
o Sec. 2-5316(a): Ducts constructed, installed and insulated
per Chapter 10, 1976 UMC. *
o Sec. 2-5316(b): Exhaust systems have damper controls.
o Sec. 2-5314(c): Gas-fired space heating equipment has
intermittent ignition devices.
o Sec. 2-5314: HVAC equipment, water heaters, showerheads and
faucets certified by the CEC.
o Sec. 2-5352(1): Water heater insulation blanket (R-12 or
greater) for storage & backup tanks for solar water heating
systems; first 5 feet of pipes closest to tank insulated
(R-3 or greater).
o Sec. 2-5312(Exception I): Pipe insulation on steam and steam
condensate return & recirculating piping.
o Sec. 2-5318(d): Swimming Pool Heating
1. System has:
a. On/off switch on heater.
b. Weatherproof instruction plate on heater.
c. Plumbed to allow for solar.
2. 75 percent thermal efficiency.
3. Pool cover.
4. Time clock.
5. Directional water inlet.
LIGHTING.AND APPLIANCE MEASURES
o Sec. 2-5352(j): Lighting - 25 lumens/watt or greater for
general lighting in kitchens and bathrooms.
o Sec. 2-5314(c): Gas fired appliances equipped with
intermittent ignition devices.
o Sec. 2-5314(a): Refrigerators, refrigerator -freezers,
freezers and fluorescent lamp ballasts certified by the CEC.
Indicate make and model number.
Enforcement
POINTS SYSTEM SUMMARY: CLIMATE
----------------------------------------------
ZONE 15
P -2R page 8
of 24
Project: SINGLE FAMILY DWELLING
COMPLY 24 v
3.20
Designer: SYNERCON DEVELOPEMENT
CORP.
Bui ing Permit No
Location: Indio
Date: 7/22/1992
Checked By
Documentation: R&R ENGINEERING
---------------------------------------------"------------------------------
AND CONSTRUCTION SVS.
Date User #
1615)
BUILDING 'DATA
-------------
Conditioned Floor Area 1778
sgft.
Number of
Stories 1
Occupancy Type Single
Fam Det
SCORE CARD
-------------------------
Measure
Points
1. Roof Insulation
-------
0.0288
(U -Value)
------
0
2. Wall Insulation
0.0585
(U -Value)
1
3. Raised Floor Insulation
0.0000
(U -Value)
-
3a. Controlled Vent.Crawlspace
0.0
(R -Value)
->
2
4. Slab Edge Insulation
0.7030
(f2 factor)
5. Infiltration Standard
0
6. Glass Heat Loss
0.65
11.0g
6
Sum 1-6
9
7. Shade Open Area Glass
SC
OH Eff
------------
a. North 96.0 5.4
----
x 0.46
---- -----
=
2.5
0
b. East 22.0 1.2
x 0.44
x 1.00 =
0.5
0
c. South 46.0 2.6
x 0.44
x 1.00 =
1.1
0
d. West 32.0 1:8
x 0.49
X. 1.00 =
0.9
0
e. Skylight 0.0 0.0
x *0.00
=
0.0
0
8. Shade Closed Area Glass
SC
OH Eff
--
a. North 96.0 5.4
----
x 0.46
---- -----
=
2.5
0
b. East 22.0 1.2
x 0.44
x 1.00 =
0.5
2
c. South 46.0 2.6
x 0.44
x 1.00 =
1.1
1
d. West 32.0 1.8
x 0.49
x 1.00 =
0.9
2
e. Skylight 0.0 0.0
x 0.00
=
0.0
0
9. Interior Thermal Mass
2.15
-1
10. Exterior Wall Mass
0.00
0
Sum 7-10
4
11. Heating System 6.600 HSPF x 0.83
Duct Eff =
5.50
Eff HSPF
0
Zonal Control: No
12. Cooling System 9.500 SEER x 0.82
Duct Eff =
7.82
Eff SEER
9
13. Water Heating (see DHW Worksheet)
_
-19
Point
Total:
3
SHADING COEFFICIENT (SC) WORKSHEET FORM S page 9 of 24
-----------------------------
Project: SINGLE FAMILY DWELLING COMPLY 24 v 3.20
Designer: SYNERCON DEVELOPEMENT CORP. Building Permit No
Location: Indio Date: 7/22/1992 Checked By
Documentation: R&R ENGINEERING AND CONSTRUCTION SVS: Date User # 1615
----------------------------------.-----------------------------------------
GENERAL INFORMATION
1.
Glazing Type:
Double
3.
Framing Type:
Metal
w/Mullions
5.
Framing/Mullion Factor:
0.81
(from Table G-10)
6.
Interior Shade Type:.
Double
Solar Bronze
7.
SC Shade Open:
0.57
(from Table G-9 or show calculation)
8.
SC Shade Closed:
0:57
(from Table G-9 or show calculation)
GLAZING, INTERIOR SHADE & FRAMING
9a. 0.57 (SC #7) x 0.81 (FMF #5) = 0.46 SC Shade Open
10a.0.57 (SC #8) x 0.81 (FMF #5) = 0.46 SC Shade Closed
EXTERIOR SHADE Exterior Shade Type: 50 % Bug Screen
11. SC Exterior Shade: 0.84 (from Table.G-11 or manufacturer's data)
12. [(0.84 (SC #11) x 0.25),+ 0.751 x 0.46 (SC #9a) = 0.44 SC Shade Open
13. [(0.84 (SC #11) x 0.25) + 0.751 x 0.46 (SC #10a) = 0.44 SC Shade Closed
---------------------------------------------------------------------------
OVERHANG FACTOR
Glass Ovrhng Dist Glass Prol OH Factor OH Factor
Orientation Area Depth Above Height Ratio Shade Open Shade Clsd
----------- ----- ------ ----- ---- ----' ---------- ----------
NO OVERHANGS
SHADING COEFFICIENT (SC) WORKSHEET FORM S page 10 of 24
------------------------------------------------
Project: SINGLE FAMILY DWELLING COMPLY 24 v 3.20
Designer: SYNERCON DEVELOPEMENT'CORP.
Location: Indio Date: 7/22/1992
Documentation: R&R ENGINEERING AND CONSTRUCTION SVS.
--------------------------------------------------------
GENERAL INFORMATION
Building Permit No
Checked By
Date User 1615
--------------------
1.
Glazing Type:.
Double
3.
Framing Type:
Wood Door w/Mullions
5.
Framing/Mullion Factor}
0.92
(from Table G-10)
6.
Interior Shade Type:
Double
Solar Bronze
7.
SC Shade Open:
0.57
(from Table G-9 or show calculation)
8.
SC Shade Closed:
0:57
(from Table G-9 or show calculation)
GLAZING, INTERIOR SHADE & FRAMING
9a. 0.57 (SC #7) x 0.92 (FMF #5)
10a.0.57 (SC #8) x 0.92 (FMF #5)
EXTERIOR SHADE
.0.52 SC Shade Open
= 0.52 SC Shade Closed
Exterior Shade Type: NO EXTERIOR SHADE
-----------------------=---------------------------------------------------
OVERHANG FACTOR
Glass Ovrhng Dist Glass Proj OH Factor OH Factor
Orientation Area Depth Above Height Ratio Shade Open Shade Clsd
----------- ----- ------ ----- ------ ----- ---------- ----------
NO OVERHANGS
DHW WORKSHEET ONE: STORAGE TYPE GAS OR ELECTRIC page 11 of 24
------------------------------------------------------------------=--------
Project: SINGLE FAMILY DWELLING COMPLY 24 v 3.20
Designer: SYNERCON DEVELOPEMENT CORP.
Location: Indio Date: 7/22/1992
Building Permit No
Checked By
Documentation: R&R ENGINEERING AND CONSTRUCTION SVS. I Date User # 1615
---------------------------------------------------------------------------
A EQUIPMENT DATA
1
Water heater type
SE
Enter SG or SE
2
Manufacturer &
---------------------------------------------------------------------------
1 Recovery
load
3
Model number
8.25 x(140-B4)x 365
A.O.Smith.DSE-050 (SE)
4
Ignition device
IID
GP, gas pilot or IID, int. ignition device
5
Tank volume
47.0
Total gallons, from CEC Appliance Directory
6
Recovery efficiency
99.9
Percent from CEC Appliance Directory
7
Standby loss
0.8
Percent/hour, from CEC Appliance Directory
8
Rated input
40956
Btu/hr, from CEC Appliance Directory
(1 kWh = 3413 Btu)
9
Number of Heaters
1
From building plans (total)
10
Insulation Jacket
Y
(Y/N) R-12 insulating jacket on the plans
B
OPERATING DATA
--------------------------------------------------------
Climate Zone.15
L
See Appendix D
2
Water heating budget
8700
KBtu/yr/unit, see Table 1
3
Tank set temp.
140
F; fixed input
4
Water main temp.
70.0
F, see Table 1
5
Daily hot water load
50
50 or 35 gallons/unit, see Table 1
6
Ambient air temp.
72.6
F, see Table 1
7
Adj Standby Losses
0.0060
See Table 2 or Appendix B
8
No. dwelling units
1
From building plans (total)'
9
Number of pumps
0
From building plans
10
Pumping energy
0.0
Watt-hr/yr per Pump, see Table 3
C WATER HEATING ENERGY CREDITS ,
---------------------------- ----------------------------------
1 Credit name See Table 5
2 Annual savings 0.0 KBtu/yr/dwelling unit., see Table 5
D CALCULATE
ANNUAL
WATER HEATING
ENERGY
(KBtu/yr)
---------------------------------------------------------------------------
1 Recovery
load
10539.4
{[B5 x
8.25 x(140-B4)x 365
x 0.001]-C2)x B8
2 Recovery energy 10549.9 D1 / A6
3 Standby loss energy 1334.1 {24 - [(D2 x 1000)/(A8 x A9 x 365)]) x 8.25
x A5 x B7 x 365 x (140-B6) x 0.001 x A9
4 Pumping energy 0.0 B9 x B10 x 3.413 x 3 x 0.001
5 Total energy 35652.1 GAS SYSTEMS: (D2 + D3 + D4) / B8
6 Water heating budget ELECTRIC: {[(D2 + D3) x 3] + D41 / B8
comparison -16952.1 KBtu/yr/unit B2 - D5
7 Water heating budget -19.1 Points (D6 / Floor Area) x 2 x B8
THERMAL MASS WORKSHEET
WS -1R page
12 of 24
Project:
SINGLE FAMILY DWELLING
------I-------------------------------
COMPLY 24
v 3.20
Designer:
SYNERCON DEVELOPEMENT CORP.
Building Permit No
Location:
Indio
Date: 7/22/1992
Checked By
Documentation: R&R ENGINEERING AND CONSTRUCTION SVS.
---------------------------------------------------------------------------
Date User
# 1615
INTERIOR
THERMAL MASS
Interior
Interior
Sides
Wall Mass
Mass
Mass
Mass Material Thick Exposed
----------------------
U -Value Area
Factor
Capacity
Concrete;
------------
Heavyweight 3:50 0
------- ------
1553.0
--------
x 1.8 =
--------
2795.4
Concrete,
Heavyweight 3.50 1
225.0
x 4.6 =
1035.0
TOTAL. 3830.4
..INTERIOR MASS FACTOR 3830.4 IMC / 1778 sqft .2; -1 -5 -
Mass listed above with a Wall U -Value denotes the Interior Mass credit
for Exterior Mass Walls, and are repeated below for Exterior Mass credit.
0 Sides Exposed indicates mass covered with surface material >= R-2.
EXTERIOR MASS WALLS Exterior Exterior
Sides IWall 'Mass Mass Mass
Mass Material Thick Exposed U -Value Area Factor Capacity
----- ----------------- -- ------ -------- --------
NONE
INTERPOLATION, WEIGHTED AVERAGE & ADDITION WORKSHEET WS -2R page 13 of 24
----------------------------------------------------------------------------
Project: SINGLE FAMILY DWELLING COMPLY 24 v 3.20
Designer: SYNERCON DEVELOPEMENT CORP. Building Permit No
Location: Indio Date: 7/22/1992
Documentation: R&R ENGINEERING AND CONSTRUCTION SVS.
INTERPOLATION
Checked By
Date User 1615
WEIGHTED AVERAGE POINTS
Type 1 Type.2 Type 3 Total Average
Item Points Area Points Area Points Area Area Points
--------- ------ ---- ------ ---- ------ ---- ----- -------
Point
Point
Point
Score
Actual
Value
Score
Score
Value
Value
Point
Item
1
Value
1
2
1
2
1
Score
Roof
4
+(
0.0288
- 0:02)
x
( -4
= 4)
/(
-----
0.04
-----
- 0.02) =
-----
0
Wall
6
+(
0.0585
- 0.04)
x
( 1
- 6)
/(
0.06
- 0.04) =
1
Slab Edge
2
+(
0.7030
- 0.70)
x
( -1
- 2)
/(
0.80
- 0.70) =
2
Glass Type 2
6
+(11.0236
-11.00)
x
( 5
- 6)
/(12.00
-11.00) =
6
N Shade
Open
0
+(
2.4845
- 2.00)
x
( -1
- 0)
/(
3.00
- 2.00) _
-0
E Shade
Open
0
+(
0.5484
- 0.00)
x
( 0
- 0)
/(
1.00
- 0.00) =
0
S Shade
Open
0
+(
1.:1467
- 1.00)
x
( 0
- 0)
/(
2.00
- 1.00) =
0
W Shade
Open
-1
+(
0.8890
- 0.00)
x
( 0
- -1)
/(
1.00
- 0.00) _
-0
N Shade
Clsd
0
+(
2.4845
- 2:00)
x
( -1
- 0)
/(
3.00
- 2.00) _
-0
E Shade
Clsd
4
+(
0.5484
- 0.00)
x
( 1
- 4)
/(
1.00
- 0.00) =
2
S Shade
Clsd
2
+(
1.1467
- 1.00)
x
( -2
- 2)
/(
2.00
- 1.00) =
1
W Shade
Clsd
6
+(
0.8890
- 0.00)
x
( 2
- 6)
/(
1.00
- 0.00) =
2
Int Mass
-1
+(
2.1543
- 2.00)
x
( 0
- -1)
/(
2.50
- 2.00) _
-1
Heating
0
+(
5.5000
- 5.14)
x
( 0
- 0)
/(
5.50
- 5.14) =
0
Cooling
0
+(
7.8217
- 7.00)
x
( 11
- 0)
/(
8.00
- 7.00) =
9
WEIGHTED AVERAGE POINTS
Type 1 Type.2 Type 3 Total Average
Item Points Area Points Area Points Area Area Points
--------- ------ ---- ------ ---- ------ ---- ----- -------
CONSTRUCTION -ASSEMBLY COMPLIANCE FORM CF -3 page 14 of 24
----------------------------.----------------------------
Project: SINGLE,FAMILY DWELLING I COMPLY 24 v 3.20
Designer: SYNERCON DEVELOPEMENT CORP.
Location: Indio Date: 7/22/1992
Documentation: R&R ENGINEERING AND CONSTRUCTION SVS.
-------------------------------------------------------
Assembly Name: R-13 Frame Wall
Assembly Type: Wall
Assembly Tilt: 90 deg (Vertical)
RuHiaing Permit No
Checked By
Date User # 1615
--------------------
Total
Framing Percentage: 15.0 %
Framing Material: Softwood, Douglas Fir -Larch
-------------------------------
Sketch of Construction Assembly
14.94 14.86
Calculation for Framing Adjustment
Summer U -Value
0.0669 x 0:85 + 0.1849 x 0.15 = 0.0846
Winter U -Value
0.0673 x 0.85 + 0:1877 x 0.15 = 0.0853
OVERALL VALUES ADJUSTED FOR FRAMING
Absorptivity: 0.70
Roughness: 'Stucco, Wood Shingles
weight: 6.4 lb/sgft
Heat Capacity: 1.84
R -Value 11.82 -- 11.72
U -Value 0.0846 0.0853
Th
R -Value
Construction Components
Fr (in)
Summer
Winter
---------------------------------------------------------------------------
Outside Air Film
0.25
0.17
1. Gypsum or Plaster Board
0.625
0.56
0.56
2. Insulation, Mineral Fiber, R-13
* 3.500
13.00
13.00
3. Gypsum or Plaster Board
0.500
0.45
0.45
4.
5.
6.
7.
8.
9.
Inside Air Film
---------------------------------------------------------------------------
0.68
0.68
Total
Framing Percentage: 15.0 %
Framing Material: Softwood, Douglas Fir -Larch
-------------------------------
Sketch of Construction Assembly
14.94 14.86
Calculation for Framing Adjustment
Summer U -Value
0.0669 x 0:85 + 0.1849 x 0.15 = 0.0846
Winter U -Value
0.0673 x 0.85 + 0:1877 x 0.15 = 0.0853
OVERALL VALUES ADJUSTED FOR FRAMING
Absorptivity: 0.70
Roughness: 'Stucco, Wood Shingles
weight: 6.4 lb/sgft
Heat Capacity: 1.84
R -Value 11.82 -- 11.72
U -Value 0.0846 0.0853
CONSTRUCTION ASSEMBLY COMPLIANCE FORM CF -3 page 15 of 24
----------------------------------------------------------------------
Project: SINGLE FAMILY DWELLING I COMPLY 24 v 3.20
Designer: SYNERCON DEVELOPEMENT CORP.
Location: Indio Date: 7/22/1992
Building Permit No
Checked By
Documentation: R&R ENGINEERING AND CONSTRUCTION SVS. I Date User # 1615
---------------------------------------------------------------------------
Assembly Name: R-13 Frame/Power Wall
Assembly Type: Wall
Assembly Tilt: 90 deg (Vertical)
Framing -Percentage: 15.0 W
Framing Material: Softwood, Douglas Fir -Larch
Calculation for Framing Adjustment
Summer U -Value
0.0463 x 0.85 + 0.0829 x 0.15 = 0.0518
Winter U -Value
0.0465 x 0.85 + 0.0835 x 0.15 = 0.0520
OVERALL VALUES ADJUSTED FOR FRAMING
-------------------------------
Sketch of Construction Assembly
Absorptivity: 0.70
Roughness: Stucco,,Wood Shingles
Weight: 12.4 lb/sqft
Heat Capacity: 2.89
R -Value
U -Value
19.31 19.22
0.0518 0.0520
Th
R -Value
Construction Components
Fr (in)
Summer
Winter
---------------------------------- ----------------------------------------
Outside Air Film
0.25
0.17
1. Stucco 1
0.875
0.17
0.17
2. Insulation, Cellular Polyisocyanurate
1.000
7.04
7.04
3. Insulation, Mineral Fiber, R-13
* 3.500
13.00
13.00
4. Gypsum or Plaster Board
0.500
0.45---
0.45
5.
6.
7.
8.
9.
Inside Air Film
0.68
0.68
Total
21.60
21.51
Framing -Percentage: 15.0 W
Framing Material: Softwood, Douglas Fir -Larch
Calculation for Framing Adjustment
Summer U -Value
0.0463 x 0.85 + 0.0829 x 0.15 = 0.0518
Winter U -Value
0.0465 x 0.85 + 0.0835 x 0.15 = 0.0520
OVERALL VALUES ADJUSTED FOR FRAMING
-------------------------------
Sketch of Construction Assembly
Absorptivity: 0.70
Roughness: Stucco,,Wood Shingles
Weight: 12.4 lb/sqft
Heat Capacity: 2.89
R -Value
U -Value
19.31 19.22
0.0518 0.0520
CONSTRUCTION ASSEMBLY COMPLIANCE FORM CF -3 page 16 of"24
------------------------7------------------------------7-------------------
Project: SINGLE FAMILY DWELLING I COMPLY 24 v 3.20
Designer: SYNERCON DEVELOPEMENT CORP.
Location: Indio Date: 7/22/1992
Building Permit No
Checked By
Documentation: R&R ENGINEERING AND.CONSTRUCTION.SVS. I Date User # 1615
---------------------------------------------------------------------------
Assembly Name: R-38 Roof/Gyp Ceiling
Assembly Type: Roof
Assembly Tilt: 0 -deg (Horizontal Roof)
Framing Percentage: 10.0 W
Framing Material: Softwood, Douglas Fir -Larch
Calculation for Framing Adjustment
Summer U -Value
0..0241 x 0.90 +0.0668 x0.10 = 0.0283
Winter U -Value
0.0243 x 0.90 + 0.0690 x 0.10 = 0.0288
OVERALL VALUES ADJUSTED FOR FRAMING
-------------------------------
Sketch of Construction Assembly
Absorptivity: 0.70
Roughness: Concrete, Asph. Shingles
Weight: 9.6 lb/sqft
Heat Capacity: 3.11
R -Value
U -Value
35.30 34.74
0.0283 0.0288
Th
R -Value
Construction Components
---------------------------------------------------------------------------
Fr (in)
Summer
Winter
Outside Air Film
0.25
0.17
1. Roofing, Built -Up
0.375
0.33
0.33
2. Plywood
0.500
0.63
0.63
3. Air Space
12.000
1.00
0.93
4. Insulation, Mineral Fiber, R-38
* 11.500
38.00
38.00
5. Gypsum or Plaster Board
0.500
0.45
0.45
6.
7.
8.
9.
Inside Air Film
---------------------------------------------------------------------------
0.92
0.61
Total
41.58
41.12
Framing Percentage: 10.0 W
Framing Material: Softwood, Douglas Fir -Larch
Calculation for Framing Adjustment
Summer U -Value
0..0241 x 0.90 +0.0668 x0.10 = 0.0283
Winter U -Value
0.0243 x 0.90 + 0.0690 x 0.10 = 0.0288
OVERALL VALUES ADJUSTED FOR FRAMING
-------------------------------
Sketch of Construction Assembly
Absorptivity: 0.70
Roughness: Concrete, Asph. Shingles
Weight: 9.6 lb/sqft
Heat Capacity: 3.11
R -Value
U -Value
35.30 34.74
0.0283 0.0288
CONSTRUCTION ASSEMBLY COMPLIANCE FORM CF73 page 17 of 24
---------------------------------------------------------------------------
Project SINGLE'FAMILY DWELLING I COMPLY 24 v 3.20
Designer: SYNERCON DEVELOPEMENT CORP.
Location: Indio Date: 7/22/1992
Documentation: R&R ENGINEERING AND CONSTRUCTION SVS.
--------------------------------------------------------
Assembly Name: Carpeted Slab
Assembly Type: Floor
Assembly Tilt: 180 deg (Horizontal Floor)
Building Permit No
Checked By
Date User # 1615
-------------------
Framing Percentage: 0.0
Framing Material: NONE
OVERALL VALUES ADJUSTED FOR FRAMING
Sketch of Construction Assembly
Absorptivity: 0.70
Roughness: Concrete, Asph. Shingles
Weight: 40.9 lb/sgft
Heat Capacity: 9.01
R -Value
3.22 3.45
U -Value 0.3106 0.2899
Th
R -Value
Construction Components
---------------------------------------------------------------------------
Fr (in)
Summer
Winter
Outside Air Film
0.25
0.17
1. Concrete, 140 lb, Not Dried
3.500
0.28
0.28
2. Flooring, Carpet and Fibrous Pad
0.250
2.08
2.08
3.
4.
5.
6.
7.
8.
9.
Inside Air Film
---------------------------------------------------------------------------
0.61
0.92
Total
3.22
3.45
Framing Percentage: 0.0
Framing Material: NONE
OVERALL VALUES ADJUSTED FOR FRAMING
Sketch of Construction Assembly
Absorptivity: 0.70
Roughness: Concrete, Asph. Shingles
Weight: 40.9 lb/sgft
Heat Capacity: 9.01
R -Value
3.22 3.45
U -Value 0.3106 0.2899
CONSTRUCTION ASSEMBLY COMPLIANCE.FORM CF -3 page 18 of 24
---------------------------------------------------------------------------
Project: SINGLE FAMILY DWELLING COMPLY 24 v 3.20
Designer: SYNERCON DEVELOPEMENT CORP.
Location: Indio. Date: 7/22/1992
Documentation: R&R ENGINEERING AND CONSTRUCTION SVS:
--------------------------------------------------------
Bui ing Permit No
Checked By
Date User # 1615
--------------------
Assembly Name: Exposed Slab
Assembly -Type,: Floor --
Assembly Tilt: 180 deg (Horizontal Floor)
Framing Percentage: 0.0 !k
Framing Material: NONE
OVERALL VALUES ADJUSTED FOR FRAMING
-------------------------------
Sketch of Construction Assembly
Absorptivity: 0.70
Roughness: Concrete, Asph: Shingles
Weight: 40.9 lb/sgft
Heat Capacity: 9.00
R -Value 1.19 1.42
U=Value 0.8403 0.7042
Th
R -Value
Construction Components
-----------------------------------------==--------------------------------
Fr (in)
Summer
Winter
Outside Air Film
0.25
0.17
1. Concrete; 140 lb, Not Dried
3.500
0.28
0.28
2. Flooring, Asphalt, Lino, Vinyl or Rubber
0.010
0.05
0.05
3.
4.
5.
6.
7.
8.
9.
Inside Air Film
-------------------------------------------------------------=-------------
0.61
0.92
Total
1.19
1.42
Framing Percentage: 0.0 !k
Framing Material: NONE
OVERALL VALUES ADJUSTED FOR FRAMING
-------------------------------
Sketch of Construction Assembly
Absorptivity: 0.70
Roughness: Concrete, Asph: Shingles
Weight: 40.9 lb/sgft
Heat Capacity: 9.00
R -Value 1.19 1.42
U=Value 0.8403 0.7042
CONSTRUCTION ASSEMBLY COMPLIANCE FORM CF -3 page 19 of 24
---------------------------------------------------
Project: SINGLE FAMILY DWELLING I COMPLY 24 v 3.20
Designer: SYNERCON DEVELOPEMENT CORP.
Location: Indio Date! 7/22/1992
Documentation: R&R ENGINEERING AND CONSTRUCTION SVS.
Assembly Name: Solid Wood Door
Assembly Type: Door
Assembly Tilt: 90 deg (Vertical)
Building Permit No
C ec a By
Date User # 1615
--------------------
Th R -Value
Construction Components Fr (in) Summer Winter
------------------------------------
Outside Air Film 0.25 0.17
1. Softwood, Douglas Fir -Larch 1.750 1.73 1.73
2.
3.
4.
5.
6.
7.
8.
9.
Inside Air Film 0.68 0.68
Framing Percentage: 0.0 W
Framing Material: NONE
Total 2.66 2.58
OVERALL VALUES ADJUSTED FOR FRAMING
R -Value
----------------------------=-- U -Value
Sketch of Construction Assembly
Absorptivity: 0.70
Roughness: Clear Pine
Weight: 5.1 lb/sqft
Heat Capacity: 1.99
2.66 2.58
0.3756 0.3872
CONSTRUCTION ASSEMBLY COMPLIANCE'.FORM CF -3 page 20. of 24
-- ------------- ------------------------------
Project: SINGLE FAMILY DWELLING I COMPLY 24 v 3.20
Designer: SYNERCON DEVELOPEMENT CORP.
,Location: Indio Date: 7/22/1992
Documentation: R&R ENGINEERING AND CONSTRUCTION SVS.
Assembly Name: Metal Door
Assembly Type: Door
Assembly Tilt: 90 deg (Vertical)
Building Permit No
CHe-c-ReEl By
Date User 1615
--------------------
Framing Percentage: '0.0
Framing Material: NONE
OVERALL VALUES ADJUSTED FOR FRAMING
R -Value. 1.80 i.87
U -Value 0.5556 0.5348
Sketch of Construction Assembly
Absorptivity: 0.70
Roughness: Smooth Plaster, Metal
Weight: "0.1 lb/sqft
Heat Capacity: 0.01
Th
R -Value
Construction Components
----------------------------------------------------------------------------
Fr (in)
Summer Winter
Outside Air Film
0.25 0.17
1. Steel
0.001
0.00 0.00
2. Air Space
1.750
0.87 1.02
3. Steel
0.001
0.00 0.00
4.
5.
6.
7.
8.
9.
Inside Air Film
------------------------7---------------------------------------------------
0.'68 0.68
Total
1.80 1.87
Framing Percentage: '0.0
Framing Material: NONE
OVERALL VALUES ADJUSTED FOR FRAMING
R -Value. 1.80 i.87
U -Value 0.5556 0.5348
Sketch of Construction Assembly
Absorptivity: 0.70
Roughness: Smooth Plaster, Metal
Weight: "0.1 lb/sqft
Heat Capacity: 0.01
CONSTRUCTION ASSEMBLY COMPLIANCE FORM CF -3 page 21 of 24
--------7----------7-------------------------------------------------------
Project: SINGLE FAMILY DWELLING COMPLY 24 v 3.20
Designer: SYNERCON DEVELOPEMENT CORP.
Location: -Indio' Date: 7/22/1992
Documentation: R&R ENGINEERING AND CONSTRUCTION SVS.
--------------------------------------------------------
Assembly Name: Double Solar Bronze
Assembly Type: Glazing
Bui ing Permit No
Checked By
Date User # 1615
---------------
Th R -Value
Construction Components Fr (in) Summer Winter
---------------------------------------------------------------------------
Outside Air Film 0.25 0.17
1. CEC Double Glazing 0.500 0.69 0.69
2.
3.
4.
5.
6.
7.
8.
9.
Inside Air Film 0.68 0.68
---------------------------------------------------------------------------
Framing Percentage: 0.0.E
Framing Material: NONE
Total 1.62 1.54
OVERALL VALUES ADJUSTED FOR FRAMING
R -Value 1.62 1.54
-- U -Value 0.6179 0.6500
Sketch of Construction Assembly
Winter Shading Coefficient: 0.57
Summer--- Shading Coefficient: 0.57
HVAC ZONE
----------
HEATING & COOLING LOAD SUMMARY
----------------------------=-------------------------------------
page
22 of 24
Project:
SINGLE FAMILY DWELLING
I COMPLY 24
v 3.20
Designer: SYNERCON DEVELOPEMENT CORP.
Location: Indio Date: 7/22/1992
Building Permit No
Checked By
Documentation: R&R ENGINEERING AND CONSTRUCTION SVS. I Date User # 1615
--------------------------------------- -----------------------------------
HVAC ZONE DESCRIPTION
HVAC Zone Name:
Heating System Name:
Cooling System Name:
System Multiplier:
Heating Schedule:
Cooling Schedule:
Fan Schedule:
Peak Load Method:
Relative Humidity:
SPACES IN_THIS ZONE PEAK
----------------------- ----
WHOLE HOUSE (Jan 12am)
TOTAL SPACE LOAD
Supply Duct Conduction -
Supply Duct Leakage
Ventilation ( 0 cfm)
Return Air Lighting Gain
Return Duct Conduction
Return Duct Leakave
Fan Motor Heat Gain
TOTAL SYSTEM LOAD
SYSTEM OUTPUT AT DESIGN CONDITIONS
WHOLE HOUSE
RHEEM RPND048J HT.PUMP
1
Residential Heating
Residential Cooling
Residential HVAC & Fans
COINCIDENT
50 %
NOTE: The TOTAL SYSTEM LOAD shown represents the minimum size equipment
which will heat or cool this zone during the design conditions indicated.
These numbers include no safety factoti and the HVAC contractor should
oversize by a reasonable margin to account for variations in weather
conditions and the pick-up capacity required to bring the zone to temper-
ature as a result of a setback thermostat: Those responsible for final
equipment selection should note that Sensible and Latent Cooling Loads are
indicated to allow for accurate comparison with manufacturer's output data.
COOLING
HEATING
PEAK
SENSIBLE LATENT
28774
(Aug 2pm)
24374
1334
28774
24374
1334
1439
1219
575
487
27
0
( 0 cfm)
0
-0
0
308
261
616
522
27
-1819
1819
29893
28682
1388
46171
34111
8671
NOTE: The TOTAL SYSTEM LOAD shown represents the minimum size equipment
which will heat or cool this zone during the design conditions indicated.
These numbers include no safety factoti and the HVAC contractor should
oversize by a reasonable margin to account for variations in weather
conditions and the pick-up capacity required to bring the zone to temper-
ature as a result of a setback thermostat: Those responsible for final
equipment selection should note that Sensible and Latent Cooling Loads are
indicated to allow for accurate comparison with manufacturer's output data.
RESIDENTIAL SPACE HEATING LOAD SUMMARY page 23 of 24
-------------------------------------------------------7-------------------
Project: SINGLE FAMILY DWELLING COMPLY 24 v 3.20
Designer: SYNERCON DEVELOPEMENT CORP Building- Permit No
Location: Indio Date: 7/22/1992 Checked By
Documentation: R&R ENGINEERING AND CONSTRUCTION -SVS. Date User 1615
---------------------------------------------------------------------------
Space Name: WHOLE HOUSE
Design Indoor Dr Bulb Temperature:
70
F
Design Outdoor Winter Dry
Bulb Temperature:
29
F
Design Temperature Difference:
41
F
Conduction
Area
U -Value
TD
Btu/hr
R-13 Frame/Power Wall
------
1504.0
x
-------
0.0520
x
----
41.0
------
= 3208
R-13 Frame Wall
360:0
x
0.0853
x
41.0
= 1260
Metal Door
20.0
x
0.5348
x
41.0
= 439
Solid Wood Door
20.0
x
0.3872
x
41.0
= 318
Double Solar Bronze
196.0
x
0.6500
x
41.0
= 5223
R-38 Roof/Gyp Ceiling
1778.0
x
0.0288
x
41.0_
= 2098
Carpeted -Slab'
Perim =
151.0
x
43
= 6493
Exposed Slab
Perim =
22.0
x
43
= 946
Exposed Slab
Perim =
4.0
x
15
= 60
Carpeted Slab
Perim =
31.0
x
15.
= 465
Infiltration: 1.00 x 0.018
x 1718 sqft
x10.0
ft x 0.75 AC
x
41.0
= 9841
TOTAL HOURLY HEAT
LOSS FOR
SPACE
28774
SUPPLY AIR QUANTITY
-------------------
Heating: 28774 Btu/hr /
[1.10 * (105
F Supply -
65 F TStat)]
=
654 cfm
RESIDENTIAL SPACE COOLING LOAD SUMMARY page 24 of 24
---------------------------------------------------------------------------
Project: SINGLE FAMILY DWELLING I COMPLY 24 v 3.20
Designer: SYNERCON DEVELOPEMENT CORP.
Location: Indio Date: 7/22/1992
Documentation: R&R ENGINEERING AND CONSTRUCTION SVS.
--------------------------------------------------------
Bui ing Permit No
Checked By
Date User 1615)
--------------------
Space Name: WHOLE HOUSE
Design Indoor Dry.Bulb Temperature:
78 F
Design Outdoor Summer
Dry Bulb Temperatures
112 F
Design Temperature Difference:
34 F
Conduction
Area
U -Value
DETD
Btu/hr
-----------------------
R-13 Frame/Power Wall
------
1504.0
x
-------
0.0518 x
----
29.6
------
= 2306
R-13 Frame Wall
360.0
x
0.0846 x
29.6
= 902
Metal Door
20.0
x
0.5556 x
29.6
= 329
Solid Wood Door
20.0
x
0.3756 x
29.6
= 222
Double Solar Bronze
196.0
x
0.6179 x
34.0
= 4117
R-38 Roof/Gyp Ceiling
1778.0
x
0.0283 x
50.0
= 2519
Infiltration: 1.00 x
0.018 x 1778
sqft x10.0
ft x 0.75 AC x
34.0
= 8161
Shaded
Unshaded
Solar Gain
Orient.
Area SGF
Area SGF
SC
Btu/hr
Double Solar Bronze
North [
-- ---
0.0 x 15
+
---- ---
76.0 x 151
----
x 0.44
------
= 505
Double Solar Bronze
North [
0.0 it 15
+
20.0 x 151
x 0.52
= 157
Double Solar Bronze
South [
0.0 x 15
+
46.0 x 321
x 0.44
= 652
Double Solar Bronze
West [
0.0 x 15
+
12.0 x 731
x 0.44
= 388
Double Solar Bronze
West [
0.0 x 15
+
20.0 x 731
x 0.52
= 766
Double Solar Bronze
East [
.0.0 x 15
+
22.0 x 731
x 0.44
= 712
Internal Gain
Op Frac.
Area
Heat Gain
Conv.
Btu/hr
----------------- - - - -
Lighting
---- - - - - --
1.00
- - - - --
x 1778.0
-
x
-- - - - - --
0.200 x
- - - --
3.413
- - - - - -
= 1214
Equipment
1.00
x 1778:0
x
0.200 x
3.413
= 1214
Occupants
1.00
x 1778:0
x
225 /
300
= 1334
TOTAL HOURLY
SENSIBLE HEAT
GAIN FOR SPACE
24374
Latent Gain
Op Frac.
Area
Heat Gain
Conv.
Btu/hr.
-----------------------
Equipment
--------
1.00
------
x 1778.0
---------
x
0.000 x
-----
3.413
------
= 0
Occupants
1.00
x 1778.0
x
225 /
300
= 1334
TOTAL HOURLY
LATENT HEAT
GAIN FOR SPACE
1334
SUPPLY AIR QUANTITY
-------------------
Cooling: 24374 Btu/hr
/ [1.08 * (
78 F TStat
-
55 F Supply)]
=
981 cfm