Loading...
06-3450 (CONR)` P.O. BOX 1504 ur�,r' • r 78-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 BUILDING & SAFETY DEPARTMENT BUILDING -PERMIT -Application Number: 06-00003450 Owner: Property Address: 52250 ROSEWOOD LN RJT HOMES - CODORNIZ APN: 772-410-997-143 -32070 - P.O. BOX 810 Application description: NEW COMML - OTHER NON-RESIDENTIAL LA QUINTA, CA 92253 Property Zoning: MEDIUM HIGH DENSITY RES. Application valuation: 68957 Fro Applicant: Architect or Engineer: 1 ----------------- LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with - Section 7000) of Division 3 of the Business and Professionals Code, and my License is in full force and effect. License CI s/: -B License No.: 690645 ta: I ntractor: WRT - Iq OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the following reason (Sec. 7031 .5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure,prior to its issuance, also requires the applicant for the permit to file a signed statement that he'or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031 .5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: 1 _ 1 I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the.structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the , improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). 1 _ I 1, as owner of the, property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed Pursuant t0 thfl GnntrArtnri' State I irense I ami 1 1 _ 1 I am exempt under Sec. , B.&P.C. for this reason Date: Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Name: - Lender's Address: LQPERMIT - - Contractor: RJT INVESTMENTS INC 1425 E. UNIVERSITY DR PHOENIX, AZ 85034 (602)257-1656 i Lic. No.: 690645 VOICE (760) 777-7012 FAX (760) 777-7011 INSPECTIONS (760) 777-7153. Date: 12/15/06 JAN 112001 LA QUINTA CE DEar . ---------------------------------------- WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: I.have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. .l have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are:' Carrier LUMBERM INS Policy Number 283257 I certify that, in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, if I should become subject to the workers' compensation provisions of Section PGIAILURE 0 of the L or Code, I sh II o with comply with those provisions.te: plicant: WAR TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN ,SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. ' APPLICANT ACKNOWLEDGEMENT IMPORTANT Application is hereby made to the Director of Building and Safety for a permit; subject to the conditions and restrictions set forth on this application. ' 1 . Each person upon whose behalf this application is made, each person at whose request and for vvliuee benerlt vvuik is ueiwimeu umur or purwarlt 10 ally parmd issued as a result of this application, .the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La-Quinta, its officers, agents and employees for any act or omission related to the work being .performed under, or following issuance of this permit. - - - 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and coppty cyclinances and ,apt. laws relating to building construction, and hereby authorize representatives of this /y t enter upon above-mentioned property f r/' spectien purposes. e: / • nature (Applicant or Agent): p / Application Number . . . . 06-00003450 Permit . . . BUILDING PERMIT Additional desc ... Permit Fee . . . . 500.00 Plan Check Fee 325.00 Issue Date *. . . . Valuation . . . . 68957 Expiration Date 6/13/07 Qty Unit Charge Per Extension BASE FEE 414.50 19.00 ---------------------------------------------------------------------------- 4.5000 THOU BLDG 50,001-100,000 85.50 Permit . . ELEC-NEW COMMERCIAL Additional desc . Permit Fee . . . . 30.90 Plan Check Fee 7.73 Issue Date Valuation . . . . 0 Expiration Date 6/13/07 Qty Unit Charge Per Extension BASE FEE 15.00 795.00 ---------------------------------------------------------------------------- .0200 ELEC GARAGE OR NON-RESIDENTIAL 15.90 Permit . . . GRADING PERMIT Additional desc . Permit Fee 15.00 Plan Check Fee.. .00 *Issue Date . . Valuation . . . . 0 Expiration Date 6/13/07 Qty Unit Charge Per Extension --------------------------------------------------------------------- BASE FEE 15.00 Permit . . . MECHANICAL Additional desc . Permit Fee 55.00 Plan Check Fee 13.75 Issue Date Valuation 0 Expiration Date 6/13/07 . Qty Unit Charge 'Per Extension BASE FEE 15.00 1.00 9.0000 EA MECH,FURNACE <=100K _ 9.00 1.00 9.0000 EA MECH APPL REP/ALT/ADD 9.00 1.00 9.0000 EA bIECK B/ C .<=3HP/ 100K ETU 9.00 2.00 ----------------------------------------- 6.5000 EA MECH VENT FAN --------------------------- 13.00 -------- Permit . . . . . .. PLUMBING LQPERMIT Application Number 06-00003450 Permit . . PLUMBING Additional desc . Permit Fee . . . . 160.50 Plan Check•Fee 40.13 Issue Date Valuation 0 Expiration Date 6/13/07 Qty Unit Charge Per Extension BASE FEE 15.00 12.00 6.00.00 EA .PLB FIXTURE 72.00 1.00 15.0000 _ EA PLB BUILDING SEWER 15.00 1.00 7.5000 EA PLB WATER HEATER/VENT 7.50 1.00 3.0000 EA PLB WATER INST/ALT/REP 3.00 1.00 9.0000 EA PLB LAWN SPRINKLER SYSTEM 9.00 3.00 3.0000 EA PLB GAS PIPE 1-4 OUTLETS 9.00 2.00 15.0000 EA PLB.GAS METER 30.00 Special Notes and Comments 795 sq. ft. comm building pool house & MECH BUILDING.December 8, 2006.11:04:08 AM JJohnson ------------------------------------------------------ Other Fees . . . . . ---------------------- . . . . ART IN PUBLIC PLACES -COM 324.78 DIF CIVIC CENTER - COMM 75.52 DIF FIRE PROTECTION -COMM 25.44 STRONG MOTION (SMI) - COM 14.48 DIF STREET MAINT FAC -COMM 18.28 DIF TRANSPORTATION -. COMM 1370.58 Fee summary Charged Paid Credited Due Permit Fee Total 761.40 .00 .00 761.40 Plan Check Total 386.61 250.00 .00 136.61 Other Fee Total 1829.08 .00 .00 1829.08 Grand Total 2977.09 250.00 .00 2727.09 LQPERMIT. P.O. BOX 1504 APPLICATION ONLY Building „.` c 78-495 CALLE TAMPICO Address �-�—� �o �l t>,: IVOdtJ Li✓ LA OUINTA, CALIFORNIA 92253 Address Ll 0 City Zip I Te I. LA- Ocji,-�fh7 VZO .S641,11- — c SSS Contractor Zip State Lic. & Classif. ' Lic•# IV1470 Arch., Engr., Designer Address Tel. Lic. # LICENSED CONTRACTOR'S DECLARATION I herebyaffirm that I provisions of Chapter 9 (commencing with Section 7000) of DZTSrio .4 Ness and Professions Code, and my license is in ful orce a effect. i o% SIGNAT1.11ATE OWNER -BUILDER DECLARATION I hereby affirm that I am exempt from the Contractor's License Law for the following reason: (Sec. 7031.5, Business and Professions Code: Any city or county which requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor's License Law, Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, or that he is exempt therefrom, and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500). O I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. (Sec. 7044, Business and Profes- sions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or im- provement is sold within one year of completion, the owner -builder will have the burden of proving that he did not build or improve for the purpose of sale). O I, as owner of the property, am exclusively contracting with licensed contractors to construct the project. (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who contracts for such projects with a contractor(s) licensed pursuant to the Contractor's License Law) O 1 am exempt under Sec. B. & P.C. for this reason WORKER'S COMPENSATION DECLARATION I hereby affirm that I have a certificate of consent to self -insure, or a certificate of Worker's Compensation Insurance, or a certified copy thereof. (Sec. 3800, Labor Code.) Policy No. Company O Copy is filed with the city. O Certified copy is hereby furnished. CERTIFICATE OF EXEMPTION FROM WORKERS' COMPENSATION INSURANCE (This section need not be completed if the permit is for one hundred dollars ($100) valuation or less). I certify that in the performance of the work for which this permit is issued, I shall not empoy any person in any manner so as to become subject to Workers' Compensation Laws of California. Date Owner NOTICE TO APPLICANT. If, after making this Certificate of Exemption you should become subject to the Workers' Compensation provisions of the Labor Code, you must forthwith comply with such provisions or this permit shall be deemed revoked. CONSTRUCTION LENDING AGENCY I hereby affirm that there is a construction lending agency for the performance of the work for which this permit is issued. (Sec. 3097, Civil Code.) Lender's Name Lender's Address This is a building permit when properly filled out, signed and validated, and is subject to expiration if work thereunder is suspended for 180 days. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter the above-mentioned property for inspection purposes. Signature of applicant Date Mailing Address City, State, Zip WHITE = BUILDING DEPARTMENT BUILDING: TYPE CONST. V AI OCC. GRP. 6961 — A.P. Number Legal Description Project Description Poo L_ 1:6 /SF= Mg5�,o dull -0&c Sq. Ft. r�/ S No. No. Dw. Size / Stories Units New �� Add ❑ Alter ❑ Repair ❑ Demolition ❑ Estimated Valuation PERMIT AMOUNT Plan Chk. Dep. Plan Chk. Bal. Const. Mech. Electrical Plumbing S.M.I. Grading Driveway Enc. Infrastructure e TOTAL REMARKS D.P.U 00 2006 ZONE: BY: Minimum Setback Distances: Front Setback fromi Center Line Rear Setback from Rear Prop. Line Side Street Setback from Center Line Side Setback from 'roperty Line FINAL DATE INSPECTOR Issued by: Date Permit Validated by: Validation: YELLOW = APPLICANT PINK = FINANCE Mc Coachella Nalley Unified School District This Box For District Use Only .83-733 Avenue 55, Thermal, CA 92274. DEVELOPER FEES PAID (760).398-5909 - Fax (760) 398-1224 AREA: .« .AMOUNT ' LEVEL ONE AMOUNT: - LEVEL TWOAMOUNT: MfEIGATIONAMOUNT: COM"D. AMOUNT: DATE: RECEIPT: CHICK #: 'IMTIAIS: CERTIFICATE OF COMPLIANCE (California Education Code 17620) Project Name: RJT� Date: 12/20/06 Owner's Name: RJT Homes Phone 1`0: 760-564-6555 Project Address: 52-250 Rosewood LN, La Quinta, CA Project Description: 1Club House APN: ' 772-410-997-143 Tract #: Lot #'s: Type of Development: Residential Commercial !XX •Industrial' Total Square Feet of Building Area: 795 SQ FT Certification of Applicant/Owners: The person signing certifies that the above information is correct and makes this statement under penalty of perjury and further represents that he/she is authorized to sign on behalf of the owner/developer. Dated:. J —0e:7 -l1� .. Signature: SCHOOL DISTRICT'S REQUIREMENTS FOR THE ABOVE PROJECT HAVE BEEN OR. WILL BE SATISFIED IN ACCORDANCE WITH ONE OF THE FOLLOWING:. (CIRCLE ONE) Education Code• Gov. Code Project Agreement Existing - Not.Subject to Fee '17620 65995 Approval Prior to 1/1/87 Requirement Number of Sq.Ft. 795 sq. ft. Amount per Sq.Ft. $ 0.42 Amount Collected' $ 333.90 Building Permit Application Completed: Yes/No By: .Carey M: Carlson, Asst. Supt., Business Services Certificate issued by: Maria L. Angulo, Facilities Secretary Signature:. NOTICE• OF 90 DAY PERIOD FOR PROTEST OF FEES AND STATEMENT OF WES, Section 66020 of the Government Code asserted by Assembly Bill 3081, effective January 1, .1997, requires that this Distict provide (1) a written notice to the project appellant, at the time of payment of school fees, mitigation payment or other exactions ("Fees"), of the 90 -day period to protest the'imposition of these Fees and (2) the amount of the fees. Therefore, in accordance with section 66020 of the Govern ment.code and other applicable law, this Notice shall serve to advise you that the 90 -day protest period in regard to such Fees or the validity thereof, commences with the payment of the fees. or performance of any other requirements as described in section 66020 of the Government code. Additionally, the amount of the fees imposed is as herein set forth, whether payable at this time or in whole or in part prior to issuance of a Certificate of Occupancy. As in the latter, the 90 days starts on. the date hereof This Certificate of Compliance is valid. for thirty (30) days from the date of issuance. Extension will be granted only for good cause, as determined by the School District; and up to three (3) such exensions may be.granted. At such time as this Certificate expires, if a building permit has, not been issued for the•project that is the subject of this�Certifcate, the owner will be reimbursed all fees that were paid to obtain this Certificate of Compliance. LT:c/mvdocs/devfees/certificate-of compliance form t3blesTO USE.doc 1/16/03-T ;� ate FtAE:PRQIEGI/ON r . 4 { RIVERSIDE COUN' FIRE DEPARTMENT In cooperation %a,itl7 the California Department of Forestry and Fire Protection %r+21A West San Jacinto Avenue • •Perris, California 92570. (951) 940-6900 Fax (951) 940-6910" v}' L �John,R' Hewklrisr Fire Chlefeki - :- 4i 1'ioudl� senrinQsthe D ate • . ;1 ` 2 y ` v. r unincorporatedr--- � -areas o"f Riverside -Cptuih , and the"". �. ,;•' . r 'Cities of•,r: OF.+. L t . -'Buildirig'Department rBeaumont'• ifs ' A Caluuesa� f.,c anonLake' ;4t,��, ARE �ODOiZAfl'Z C 1,� house �,'" t • .fir � �i r r +e .�4: . .. �, � -Coac.helltil ..�.. L. DesertHot Sprni�s `The Riverside County Fire Department is granting the Fire clearance for the following s �-, . =• ,'location! 2' -2SO R OSP"��I 011i>V2 Indian Wells ease'ca11'if you should have questions 760-863-8886I. • 'dib; La:Qumta t.4- ? , Moeaa valleys Palm Deseif Penis , + r Respectfully Rau"ch0MllaQeti'�t Sari{Jacmto ' Y rt ri Jason bble Temecula,. Fire Systems Inspector SSS } ' + Hoard of Siipen+isors ,� > 4 K v Distract r •+ r a • -r 'JohnTavaglione .err Distncf23`' 44 (' ` District 3 �.. •r s� i ! Roy.Wilsoq : ; #fir ►• , _ ' Distiict 4Al Msnon Ashley; t a{ _ '• jj� ,'4 c .- S � ,r � c {�177JJ { � s � `•i` ct+ �, "' " { �- ` _ � r John R. Hawkins Fire Chief Proudly serving the Unincorporated Areas of Riverside County and the Cities of Banning Beaumont .y Calimesa 4 Canyon Lake " Coachella 4. Desert Hot Springs 4. Indian Wells 4. Indio 4. Lake Elsinore . La Quinta 4. Moreno Valley Palm Desert Perris Rancho Mirage San Jacinto .- Temecula Board of Supervisors Bob Buster, District 1 John Tavaglione, " District 2 Jim Venable, District 3 Roy Wilson, District 4 Marion Ashley, District 5 RIVERSIDE COUNTY FIRE DEPARTMENT In cooperation with the California Department of Forestry and Fire Protection 210 West San Jacinto Avenue • Perris, California 92570 • (909) 940-6900 • Fax (909) 940-6910 January 11, 2007 To: City of La Quinta Building Department Re: Release for Building Permits LAQ-06-BP-110 / Cordoniz-Clubhouse(pool .house) and Pool Maintenance Building at 52250 Rosewood Lane, La Quinta, CA The Riverside County Fire Department hereby releases the above referenced project for issuance of a building permit at the discretion of the Building Department. The water plans require modifications of additional hydrants. There are current active hydrants in the area. Respectfully, Tracy Hobday Chief Fire Department Planner By %--Sonia Coole Fire Safety Specialist EMERGENCY SERVICES DIVISION • PLANNING SECTION • INDIO OFFICE 82-675 Highway 111, 2nd FI., Indio, CA 92201 • (760) 863-8886 • fax (750) 863-7072 John R. Hawkins Fire Chief Proudly serving the Unincorporated ' Areas of Riverside County and the Cities of. Banning Beaumont 4. Calimesa 4. Canyon Lake .P. - Coachella ., Desert Hot Springs Indian Wells 4. Indio 4. Lake Elsinore La Quinta S• Moreno Valley Palm Desert 4. Perris 4. Rancho Mirage .; San Jacinto 4. Temecula Board of Supervisors Bob Buster, District 1 John Tavaglione, District 2 Jim Venable, District 3 Roy Wilson, District 4 Marion Ashley, District 5 RIVERSIDE COUNTY FIRE DEPARTMENT In cooperation with the California Department of Forestry and Fire Protection 210 West San Jacinto Avenue • Perris, California 92570 • (909) 940-6900 • Fax (909) 940-6910 r January 9, 2007 RJI Homes 80109 Avenue 52 La Quinta, CA 92253 - r r, Re: Non -Structural Building Plan Review LAQ-06-BP-110_/ Condrniz — Pool House &-Pool Maintenance Building at 52250 Rosewood Lane, La,Quinta, CA Fire Department personnel have reviewed and approved the plans you submitted for the above referenced project. Please be advised the following conditions apply as a parl of the conditions for the issuance of a building permit. 1) The Fire Department is required to set a minimum fire flow for the remodel or construction of all commercial buildings using the procedure established in the 2001 CFC. Afire flow of 1500 gpm for a 2 -hour duration at.20 psi residual operating pressure must be available before any combustible material is placed on the job site. 2) The required fire flow shall be available from a Super hydrant(s) (6" x 4" x 21/2' x 21/2') located not less than 25' or more than 165' from any portion of the building(s) as -neasured along approved vehicular travel ways. 3) Prior to the issuance of a building permit, applicant/developer shall furnish one blueline copy of the water system plan's to the Fire Department for review. Plans shall con-orm to the fire hydrant types, location and spacing, and the system shall meet the .fire flow requirements. Plans must be signed by a registered Civil Engineer and/or the local water company with :he following certification: "I certify that the design of the water system is in accordance with the requirements prescribed by the Riverside County Fire Department". 4) Install Knox Key Lock box, Model 3200, mounted per recommended standard of the Knox Company. If the building/facility is protected with a fire alarm system or burglar alarm system, the lock boxes will require "tamper" monitoring. Special forms are available from this office for the ordering of the Key Switch. This form must be authorized and signed by this office for the correctly coded system to be purchased. 5) Install portable fire extinguishers per Title -19, but not less than 2A10BC'in rating. Contact a certified extinguisher company for proper placement and spacing of equipment. 6) Approved building address shall be placed in such a position as to be plainly visible and legible . EMERGENCY SERVICES DIVISION • PLANNING SECTION • INDIO OFFICE 82-675 Highway 111, 2T FI., Indio, CA 92201 • (760) 863-8886 • Fax (760) E63-7072 from the street. Said numbers shall contrast with their background. 7) Electrical room door shall be posted "ELECTRICAL ROOM" on the outside of door. Applicant/installer shall be responsible to contact the Fire Department to schedule inspections. Requests for inspections are to be made at least 72 hours in advance and may be arranged by calling (760) 863-8886. All questions regarding the meaning of these conditions should be referred to the Fire Department Planning & Engineering staff at (760) 863-8886. Sincerely, Tracy Hobday Chief Fire Department Planner �a By Sonia Coole Fire Safety Specialist EMERGENCY SERVICES DIVISION • PLANNING SECTION • INDIO OFFICE 82-675 Highway 111, 2n° FI., Indio, CA 92201 • (760) 863-8886 . Fax (760) 863-7072 11/20/2006 ION 13:48 F� 760 360 0548 IcKinzie Electrical Cont -)-)-) VT HODS: 2001/001 . DATE: 11-20-06 PROJECT: CORDORNIZ CONTRACTOR RJT HOMES ADDRESS: 52ND AND JEFFERSON LA QUINTA SUBJECT. LOAD CALCULATIONS POOL BUILDING 503 SQUARE FEET@ 3 WATTS 1509 WATTS 1 -AC UNIT @ 4000WAM I � - -TREADMILL MACHINE 1500WATTS 1- FOUNTAIN CIRCUITS 4000WATTS REMAINDER OF 1ST 10,000 WATTS X 40% 1009 X 40% = 403 WATTS, 1 ST 10,000 WATTS + REMAINDER 403 WATTS = 10,403wg"" 2-GFI CIRCUITS TO BATHS 1500 WATTS_ OL NT LOAD 80 /!��-�P` POFUTURE LA LOAD 4000 ATIS TOTAL 23,903 WATTS DMbED BY 240 VOLT = 9.59AMP,S, � • F¢®�g OAST �UCTICN . USE 200 AMP MAIN ELECTRICAL SERVICE Reslden.tlal Cpal�grClal Industrial IBM uc,C C.10 2408tla 79607 Country Club Dr, 0760/360-0728 suito 3 0760/360-0548 Bermuda Dunos, CA 92201 Omckinzieele&it@oorthlink.net www.mdcumeotomkku.corn PERFORMANCE CERTIFICATE OF COMPLIANCE Part 1 of 3 PERF -1 PROJECT NAME This Certificate of Compliance lists the building features and performance specifications needed to comply with Title 24, Parts 1 and 6 of the DATE CODORNIZ Fitness Center DATE OF PLANS 11/27/2006 PROJECT ADDRESS Mark Berkheimer CLIMATE ZONE 15 La Qunita NONRESIDENTIAL HIGH RISE RESIDENTIAL consistent with the other compliance forms and'worksheets, with the specifications, and with any other calculations submitted with thi PRINCIPAL DESIGNER - ENVELOPE TELEPHONE Building Permit # DTJ Design 303-443-7533 California as a civil engineer, mechanical engineer, or I am a licensed architect. DOCUMENTATION AUTHOR TELEPHONE Checked by/Date LDI Mechanical, Inc. (951) 340-9685 Enforcement Agency Use GENERAL INFORMATION This Certificate of Compliance lists the building features and performance specifications needed to comply with Title 24, Parts 1 and 6 of the California Code of Regulations. This certificate applies only to a Building using the performance compliance approach. The documentation preparer hereby certifies that the documentation is accurate and co tete. DATE OF PLANS BUILDING CONDITIONED FLOOR AREA 480 Sq.Ft. Mark Berkheimer CLIMATE ZONE 15 BUILDING TYPE NONRESIDENTIAL HIGH RISE RESIDENTIAL consistent with the other compliance forms and'worksheets, with the specifications, and with any other calculations submitted with thi HOTELIMOTEL GUEST ROOM PHASE OF CONSTRUCTION NEW CONSTRUCTION ADDITION ❑ F-1 7 1. 1 hereby affirm that I am eligible under the provisions of Division 3 of the Business and Professions Code to EXISTING + ADDITION/ALTERATION STATEMENT OF COMPLIANCE This Certificate of Compliance lists the building features and performance specifications needed to comply with Title 24, Parts 1 and 6 of the California Code of Regulations. This certificate applies only to a Building using the performance compliance approach. The documentation preparer hereby certifies that the documentation is accurate and co tete. DOCUMENTATION AUTHOR SIG TU DATE Mark Berkheimer 11112--79— The Principal Designer hereby certifys that the proposed building dbsigfi repr 69 ent d in thist of construction documents is consistent with the other compliance forms and'worksheets, with the specifications, and with any other calculations submitted with thi permit application. The proposed building as designed meets the energy efficiency requirements contained in sections 110, 116, through 118, and 140, 142, 143 or 149 of Title 24, Part 6. ENV. LTG. MECH. ❑ F-1 7 1. 1 hereby affirm that I am eligible under the provisions of Division 3 of the Business and Professions Code to sign this document as the person responsible for its preparation; and that I am licensed in the State of California as a civil engineer, mechanical engineer, or I am a licensed architect. ❑ E] % 2. 1 affirm that I am eligible under the provisions of Division 3 of the Business and Provessions Code Section 5537.2 or 6737.3 to sign this document as the person responsible for its preparation; and that I am a licensed contractor performing this work. ❑ R ❑ 3. 1 affirm that I am eligible under Division 3 of the Business and Professions Code to sign this document because it pertains to a structure or type of work described as exempt pursuant to Business and Professions Code Sections 5537, 5538, and 6737.1. (These sections of the Business and Professions Code are printed in full in the Nonresidential Manual.) ENVELOPE COMPLIANCE Indicate location on plans of Note Block for Mandatory Measures ENV -1 Required Forms PRINCIPAL ENVELOPE DESIGNER - NAME SIGNATURE LIC. NO. DATE DTJ Desicin LIGHTING COMPLIANCE Indicate location on plans of Note Block for Mandatory Measures Lighting Compliance Not In The Scope Of hfS SLIt)Tf11ttdi Required Forms PRINCIPAL LIGHTING DESIGNER - NAME SIGNATURE LIC. NO. DATE MECHANICAL COMPLIANCE Indicate location on plans of Note Block for Mandatory Measures MECH-1 MECH-2 MECH-3 MECH-5 Required Forms PRINCIPAL MECHANICAL DESIGNER- NAME SI AT U LIC. NO. DATE LDI Mechanical5p ?6T4 662 Run Initiation Time: 11127/06 08:40:45 Run Code: 11646456x5 EnergyPro 4.2 by EnergySoft ' User Number: 4693 Job Number: Page:1 of 11 ` Building Orientation... Number of Stories Number of Systems -. Number.of Zones ^.; N 0 degConditioned Floor Area-` . Unconditioned Floor Area Conditioned Footprint Area -Fuel Type " 480 sgft. Sgft. ' Sgft." t 1 FPERFORMANCE CERTIFICATE OF COMPLIANCE ; Part 2 of 3:: PERF -1 480 , 2 Natural Gas PROJECT. NAME r DATE CODORNIZ Fitness Center 11/27/2006. ANNUAL TDV.ENERGY USE SUMMARY kBtu/s ft- r ' �Standard Proposed P Com liance. P ENERGY COMPONENT Design Design , , Margin IStiMird Proposes - ' Space Heating, 5.58 ; 4.80 0.78����W�'' 3 Space Cooling 422.60, 425.94 -3.34 F indoor Fans'' 151.85 142.47 " 9.38 - _Heat :Rejection - 0.00 0.00 0:00'' x Pumps & Misc. 0.00.. 0.00. " .0.00. Domestic Hot Water- 0.00 0.00 0.00 Lighting -51.41. 51.41 0.00 . ., Receptacle s 20.22 ` .. :. 20.22 0.00 RBCS° f Process 0.00 o.00 } 0.00 - � '. _. ... ' "'_ ,.: ' ..• - •...:. - — 90-720�7�80�210290270;300"33 �> X420 . TOTALS:' 651.66 ` 644.84. 6.82 ke w5aiarr ; ', • , Percent better -than Standard: - 1.0% ( 1.0% . excluding process) BUILDING"COMPLIES.:.` i 1 GENERAL INFORMATION - ` Building Orientation... Number of Stories Number of Systems -. Number.of Zones ^.; N 0 degConditioned Floor Area-` . Unconditioned Floor Area Conditioned Footprint Area -Fuel Type " 480 sgft. Sgft. ' Sgft." t 1 . o ~`� 480 , 2 Natural Gas Standard .. Proposed a Lighting Power Density- 0.775 wisgff. 0.775 wisgft. r , Prescriptive Env. Heat Loss 225 Blum 211 Btum Prescriptive, Env. Heat Gain 19,776 Btuih-F 17,938 Btwn-F c Remarks: , .. ll - Run Initiation Time: 11/27/06 08:40:45 Run Code: 1164645645 EneigyPro 4.2 by EnergySoft : r User Number: 4693 Job Number: ji Page:2 of 11 1'. `� - - - :♦.r., .'fie, .. PERFORMANCE CERTIFICATE -OF COMPLIANCE Part 3 of 3 PERF '1 PROJECT NAME CODORNIZ Fitness Center DATE '11/27/2006 ZONE INFORMATION Floor Inst. Area LPD System Name Zone Name Occupancy Type (sqft.) (W/sf)1 Ctrl Credits (W/W Allowed LPD Proc.. Loads' (W/sf), Area . Tailored (W/S3 (W/S4 Fitness Center Excercise Room Exercise, Gymnasium 210 '1.00 Restroom Corridor/Restroom/Support 270 '0.60 , . ra'L Notes: 1. See LTG -2-C 2. See LTG -4-C 3. See LTG -5-C 4. See LTG -6-C (items marked with asterisk, see LTG -2 -C by others) (by others) Items above require special documentation , EXCEPTIONAL CONDITIONS COMPLIANCE CHECKLIST ' The local enforcement agency should pay special attention to the items specified in this checklist. These items reWlre special written justification and documentation, and special verification to be used with the performance approach. The local enforcement ageicy determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special austification and documentation submitted. 1 ' The exceptional features listed in this performance approach application have specifically been reviewed. Adequate_ written justification and documentation for their use have been provided by the applicant. ' Authorized Signature or Stam Run Initiation Time: 11127106 08:40:45 Run Code: 1164645645 EnergyPro 4.2 by EnergySoft User Number: 4693 Job Number: Page:3 of 11 • 1 1 CERTIFICATE OF COMPLIANCE ENV -1-C ' PROJECT NAME DATE CODORNIZ Fitness Center 11/27/2006 OPAQUE SURFACES 1 # Surface Type Area U -Fac. Insulation Cay. Cont. Act. Am. Tilt Cond: Status Joint Appendix IV Reference Location / Comments 1 Wall 162 0.102 R-13 R-0.0 315 90 New 09-A3 Excercise Roorr 2 Wall 99 0.102 R-13 R-0.0 225 90 New 09-A3 Excercise Room 3 Wall 96 0.102 R-13 R-0.0 45 90 New 09-A3 Excercise Room 4 Wall 162 0.102 R-13 R-0.0 135 90 New 09-A3 Excercise Room 5 Roof 210 0.043 R-22 R-0.0 135 0 New 02-A24 Excercise Room 6 Wall 1 160 0.102 R-13 R-0.0 135 90 New 09-A3 Restroom 7 Wall 132 0.102 R-13 R-0.0 135 90 New 09-A3 Restroom 8 Wall 156 0.102 R-13 R-0.0 225 90 New 09-A3 Restroom 9 Wall 56 0.102 R-13 R-0.0 135 90 New 09-A3 Restroom 10 Door 24 1.450 None R-0.0 135 90 New 28-A1 Restroom 11 Roof 130 0.043 R-22 R-0.01 135 0 New 02-A24 Restroom 12 Wall 153 0.102 R-13 R-0.0 315 90 New 09-A3 Restroom 13 Wall 154 0.102 R-13 R-0.0 135 90 1 New 09-A3 Restroom 14 Wall 26 0.102 R-13 R-0.0 135 90 New 09-A3 Restroom 15 Door 24 1.450 None R-0.0 135 90 New 28 -At Restroom 16 Wall 130 0.102 R-13 R-0.0 45 90 New 09-A3 Restroom 17 Roof 140 0.043 R-22 R-0.0 135 0 New 02-A24 Restroom N, E, A, R (New, Existing, Altered, Removed) ' FENESTRATION SURFACES ❑More than or equal to 10,000 sq.ft. of site -built fenestration area must include a label certificate either issued by NFRC or provide a CEC Default Label Certificat3 using the default Ll -factors from Standards Table 116-A and B. Certificate shall be filed In the contractor's project office during construction and in the building managers office after construction # Tvpe # Exterior Shade Type Window Overhang Left Fin Right Fin SHGC Hgt. Wd. Len. H t. LExt.RExt. Dist. Len. Hgg. Dist. Len. H t. Area U -Fac' SHGC' Act. Am. Cond. Stat. Glazing_y a Location/ Comments 1 Window Rear SW 45 0.390 NFRC 0.35 NFRC 225 New V LOW E DUAL OPER Excercise Room 2 Window Front (NE) 48 0.360 NFRC 0.35 NFRC 45 New V LOW E DUAL SLD DR Excercise Room 3 Window Rear (SW) 4 0.350 NFRC 0.37 NFRC 225 New VINYL LOW E DUAL FIXED Restroom 4 Window Right NW 7 0.350 NFRC 0.37 NFRC 315 New VINYL LOW E DUAL FIXED Restroom ' (1) 1.1 -factor Type: 116A Default Table from Standards, Table NI -1 Default Table from the ACM Manual Appendix, NFRC Labeled value. (2) SHGC Type: 1168 Default Table from Standards, COG Center of Glass, NFRC Labeled Value EXTERIOR SHADING # Exterior Shade Type Window Overhang Left Fin Right Fin SHGC Hgt. Wd. Len. H t. LExt.RExt. Dist. Len. Hgg. Dist. Len. H t. 1 None 0.76 2 None 0.76 3 None 0.76 4 None 0.76 MINIMUM SKYLIGHT AREA FOR LARGE ENCLOSED SPACES ❑ The proposed building contains an enclosed space with floor area greater than 25,000 sq.ft, a ceiling height greater than 15 feet and a LPD for general lighting of at least 0.5 W/sq.ft. If this ' box is checked, ENV -4-C must be filled out when submitting under the Prescriptive Compliance Approach. Run Initiation Time: 11/27/06 08:40:45 Run Code: 1164645645 EnergyPro 4.2 by EnergySoft User Number: 4693 Job Number: Page:4 of 11 L, CERTIFICATE OF COMPLIANCE MECH-1-C PROJECT NAME DATE CODORNIZ (Fitness Center) 11/27/2006 �] Designer: This form is to be used by the designer and attached to the plans. Listed below are all the acceptance tests for mechanical systems. The designer is required to check the boxes by all acceptance tests that apply and list all equipment that requires an acceptance test. If all equipment of a certain type requires a test, list the equipment description and the number of systems to be tested in parentheses. The NJ number designates the Section in tha Appendix of the Nonresidential ACM Manual that describes the test. Also indicate the person responsible for performing the tests (i.e. the installing contractor, design professional or an agent selected by the owner). Since this form will be part of the plans, completion of this section will allow the responsible party to budget for the scope of work appropriately. Building Departments: SYSTEM ACCEPTANCE. Before an occupancy permit is granted for a newly constructed building or space, or a new space. -conditioning system serving a building or space is operated for normal use, all control devices serving the building or space shall be certified as meeting the Acceptance Requirements for Code Compliance. In addition a Certificate of Acceptance, MECH-I-A Form shall be submitted to the building department that certifies plans, specifications, installation rPrtifiratac nnrt nnPratinn and mnintPnanrP infnrmatinn moot tha ranuiramante of Rartinn 1n-11)Athl -1 Titla 9d Pnrt R STATEMENT OF COMPLIANCE ❑ MECH-2-A: Ventilation System Acceptance Document -Variable Air Volume Systems Outdoor Air Acceptance -Constant Air Volume Systems Outdoor Air Acceptance Equipment requiring acceptance testing Test required on all New systems both New Construction and Retrofit. y MECH-3-A: Packaged HVAC Systems Acceptance Document Equipment requiring acceptance testing Test required on all New systems both New Construction and Retrofit. ❑ MECH-4-A: Air -Side Economizer Acceptance Document Equipment requiring acceptance testing Test required on all New systems both New Construction and Retrofit. Units with economizers that are installed at the factory and certified with the commission do not require equipment testing but do require construction inspection. MECH-5-A: Air Distribution Acceptance Document Equipment requiring acceptance testing This test required If the unit serves 5,000 ft2 of space or less and 25% or more of the ducts are in nonconditioned or semiconditioned space like an attic. New systems that meet the above requirements. Retrofit systems that meet the above requirements and either extend ducts, replace ducts or replace the packaged unit. ❑ MECH-6-A: Demand Control Ventilation Acceptance Document Equipment requiring acceptance testing All new DCV controls installed on new or existing packaged systems must be tested. ❑MECH-7-A: Supply Fan Variable Flow Control Acceptance Document Equipment requiring acceptance testing All new VA fan volume controls installed on new or existing systems must be tested ❑ MECH-8-A:-Hydronic System Control Acceptance Document -Variable Flow Controls Applies to chilled and hot water systems. -Automatic Isolation Controls Applies to new boilers and chillers and the primary pumps are connected to a common header. -Supply Water Temperature Reset Controls Applies to new constant flow chilled and hot water systems that have a design capacity greater than or equal to 500,000 Btulhr. -Water-loop Heat Pump Controls Applies to all new waterloop heat pump systems where the combined loop pumps are greater than 5 hp. -Variable Frequency Controls Applies to all new distribution pumps on new variable flow chilled, hydronic heat pump or condenser water systems where the pumps motors are greater than 5 hp. Equipment requiring acceptance testing EnergyPro 4.2 by EnergySoft User Number: 4693 Job Number: Page:5 of 11 4 IR SYSTEM REQUIREMENTS Part 1 of 2. MECH-2-6 ' PROJECT NAMEDATE COD'ORNIZ (Fitness Center) 11/27/2006 ' SYSTEM FEATURES 'AIR SYSTEMS, Central or Single Zone ITEM OR SYSTEM TAG(S) Fitness Center ' Number of Systems - 1 T-24 MANDATORY MEASURES Section Reference on Plans or Specification 112(a) . Heating Equipment Efficiency 4 Cooling Equipment Efficiency, ' Heat Pump Thermostat Furnace Controls 112(b) Natural Ventilation ' Minimum Ventilation 112(c), 115(a) VAV Minimum Position Control Demand Control Ventilation, Yes Time Control 121(b) Setback and Setup Control ' Outdoor Damper Control 121 c Isolation Zones ' Pipe Insulation Duct Insulation 112(a) . 8.00 HSPF 4 112(a) 13.0 SEER / 11.2 EER 112(b) Yes 112(c), 115(a) n/a 121(b) Yes 121(b) 201 cfm ° 121 c No 121(c) No + 121(c), 122(e) Programmable Switch 122(e) Heating & Cooling Required 122(f) Auto 122(g) n/a 123 124 R-4.2 r PRESCRIPTIVE MEASURES , Calculated Heating Capacity x 1.43 2 Proposed Heating Capacity 2 ' Calculated Sensible Cooling Capacity X'11.212 Proposed Sensible Cooling Capacity 2 Fan Control ' DP Sensor Location Supply Pressure Reset (DDC only) Simultaneous Heat/Cool Economizer Heating Air Supply Reset Cooling Air Supply Reset Duct Sealing for Prescriptive Compliance3 144 a & b - n/a 144 a & b 36,427 btuh ` 144 a & b n/a 144 a & b 23,839 btuh 144 c Constant Volume 144 (c) 144 c Yes 144 d No + 144 a No Economizer 144 f Constant Tem 144 (f) Constant Temp 144 (k) No 1: For each central and single zone air systems (or group of similar units) fill in the reference to sheet number and/or specification section and paragraph number where the t required features are documented. If a requirement is not applicable, put "N/A° in the column. 2: Not required for hydronic heating and cooling. Either enter a value here or put in reference of plans and specificatons per footnote 1. 3: Enter Yes if System is: Constant Volume, Single Zone; Serves < 5,000 sgft; Has > 25% duct in unconditioned space. Duct sealing is regaired for Prescriptive Compliance, ' see PERF -1 for performance method duct sealing requirements. NOTES TO FIELD - For Buildina De artment Use Only f rs.+;; +; v^ '9 a. ` M.0 & "t'.,' _4 • - r• rpt% '-'wY Run Initiation Time: 11/27/06 08:40:45 Run Code: 1164645645 EnergyPro 4.2 by EnergySoft User Number: 4693 Job Number: Page:6 of 11 i MECHANICAL VENTILATION MECH-3-C PROJECT NAMEDATE CODORNIZ (Fitness Center) 11/27/2006 PRESCRIPTIVE REHEAT LIMITATION (Section 144(d)) MECHANICAL VENTILATION Section 121 (b)2) AREA BASIS OCCUPANCY BASIS `VAV MINIMUM A B C D E F G H I J K L M N r ZONE/SYSTEM D� ins rT. d G 0 m C7 �v 3 °o Oo`Q3 x D o n 2) 3 mac. )03 'C f7D `° °, v ��n N I T 3 34,110 O m0� x C 0 7 vim WQ x o Gt GD m 0 03CD T. N. 3 D 3 �' n`DO, T N 3"a �, a TW 3x N. O x A C M wad OUR) x r= r 3� oto � 'o D rn �. D. Excercise Room 210 0.15 32 1 1 32 160 1 1 Restroom 270 0.15 40 40 41 Fitness Center Total 72 201 Minimum ventilation rate per Section 121 TaDle 121- E Based on fixed seat or the greaterof the ex cted number of occupants and 50% of the CBC occupant load fore ress purposes fors aces without fixed seatin . H Required Ventilation Air REO'D V.A. is the larger of the ventilation rates calculated on and AREA or OCCUPANCY BASIS column D or G). I Must be greater than orequal to H or use Transfer Air column N to make up the difference. J Design fan supply cfm (Fan CFM) x 30%; or K Condition area ft. sq.) x 04 cfmttt. .& or L Maximum of Columns H, J. K, or 300 cfm M This must be less than or equal to Column L and greater that or equal to the sum of Columns H + N. N Transfer air must be provided where the Required Ventilation Air (column H) is greater than the Design Minimum Air (column M). Where required, trawler air must be greater than or equal to the difference between the Required Ventilation Air (column H) and the Design Minimum Air (column M), column H - M. - Ener yPro 4.2 by Ener ySoft User Number: 4693 Job Number: Page: 7 of 11 MECHANICAL EQUIPMENT DETAILS Part 1 of 2 MECH-5-C PROJECT NAME CODORNIZ Fitness Center ]:DA:TE1 1/27/2006 71 CHILLER AND TOWER SUMMARY Efficiency Tons PUMPS Equipment Name Equipment Type Qty. Tot. Qty GPM BHP Motor Eff. Drive Eff. Pump Control DHW BOILER SUMMARY System Name Energy Standby ITANK IN Rated Vol. Condition Factor Loss or Ext. Distribution Type Qty Input (Gals.) Status or RE Pilot I R -Val. CENTRAL SYSTEM RATINGS HEATING COOLING Aux. Condition System Name System Type City Output kW Eff. Out ut Efficiency Status Economizer Type YORK ERD036 / F2RP042 Split DX 1 31,000 5. 5.00 HSPF 34,600 13.0 SEER/ 11.2 EER New No Economizer FENVELOPE MANDATORY MEASURES ENV - PROJECT NAME DATE CODORNIZ (Fitness Center) 11/27/2006 DESCRIPTION Designer Enforcement § 118(a) Installed Insulating Material shall have been certified by the manufacturer to comply with the California Quality Standards for insulating material, Title 20, Chapter 4, Article 3. § 118(c) All Insulating Materials shall be installed in compliance with the flame spread rating and smoke density requirements of Sections 2602 and 707 of Title 24, Part 2. § 117(a) All Exterior Joints and openings in the building that are observable sources of air leakage shall be caulked, gasketed, weatherstripped or otherwise sealed. § 116(b) Site Constructed Doors, Windows and Skylights shall be caulked between the unit and the building, and shall be weatherstripped (except for unframed glass doors and fire doors). § 116(a)1 Manufactured Doors and Windows installed shall have air infiltration rates not exceeding those shown in Table Number 1-E. ofthe Standards. Manufactured fenestration products must be labeled for U -value according to NFRC procedures. § 118(e) Demising Walls in Nonresidential Buildings: The opaque portions of framed demising walls in nonresidential buildings shall have insulation with an installed R -value of no less than R-13 between framing members. EnergyPro By EnergySoft User Number: User Job Number: Page:9 of 11 MECHANICAL MANDATORY MEASURES Part 1 of 2 MECH-MM PROJECT NAME DATE CODORNIZ (Fitness Center) 11/27/2006 DESCRIPTION Designer Enforcement Equipment and Systems Efficiencies §111 Any appliance for which there is a California standard established in the Appliance Efficiency Regulations will comply with the applicable standard. § 115(a) Fan type central furnaces shall not have a pilot light. § 123 Piping, except that conveying fluids at temperatures between 60 and 105 degrees Je• Fahrenheit, or within HVAC equipment, shall be insulated in accordance with Standards Section 123. ❑ § 124 Air handling duct systems shall be installed and insulated in compliance with Sections 601, 602, 603, 604, and 605 of the 2001 CMC Standards. Controls § 122(e) Each space conditioning system shall be installed with one of the following: § 122(e)1A Each space conditioning system serving building types such as offices and manufacturing facilities (and all others not explicitly exempt from the requirements of Section 112 (d)) shall be installed with an automatic time switch with an accessible manual override that allows operation of the system during off -hours for up to 4 hours. The time switch shall be capable of programming different schedules for weekdays and weekends and have program backup capabilities that prevent the loss of the device's program and time setting for at least 10 hours if power is interrupted; or ❑ § 122(e)1B An occupancy sensor to control the operating period of the system; or § 122(e)1C A 4 -hour timer that can be manually operated to control the operating period of the system. § 122(e)2 Each space conditioning system shall be installed with controls that temporarily restart and temporarily operate the system as required to maintain a setback heating and/or a setup cooling thermostat setpoint. § 122(8) Each space conditioning system serving multiple zones with a combined conditioned floor area more than 25,000 square feet shall be. provided with isolation zones. Each zone: shall not exceed 25,000 square feet; shall be provided with isolation devices, such as valves or dampers, that allow the supply of heating or cooling to be setback or shut off independently of other isolation areas; and shall be controlled by a time control device as described above. ❑ § 122(a&b) Each space conditioning system shall be controlled by an individual thermostat that responds to temperature within the zone. Where used to control heating, the control shall be adjustable down to 55 degrees F or lower. For cooling, the control shall be adjustable up to 85 degrees F or higher. Where used for both heating and cooling, the control shall be capable of providing a deadband of at least 5 degrees F within which the supply of heating and cooling is shut off or reduced to a minimum. § 122(c) Thermostats shall have numeric setpoints in degrees Fahrenheit (F) and adjustable setpoint stops accessible only to authorized personnel. § 112(b) Heat pumps shall be installed with controls to prevent electric resistance supplementary heater operation when the heating load can be met by the heat pump alone. EnergyPro By EnergySoft User Number: User Job Number: Page: 10 of 11 MECHANICAL MANDATORY MEASURES Part 2 of 2 MECH-MM PROJECT NAMEDATE CODORNIZ (Fitness Center) 11/27/2006 k Description Designer Enforcement Ventilation § 121(e) Controls shall be provided to allow outside air dampers or devices to be operated at the ventilation rates as specified on these plans. ❑ § 122(f) Gravity or automatic dampers interlocked and closed on fan shutdown shall be provided on the outside air intakes and discharges of all space conditioning and. exhaust systems. ❑ § 122(f) All gravity ventilating systems shall be provided with automatic or readily accessible manually operated dampers in.all openings to the outside, except for combustion air openings. § 121(f)l Air Balancing: The system shall be balanced in accordance with the National .Environmental Balancing Bureau(NEBB) Procedural Standards (1983), or Associated Air Balance Council (AABC) National Standards (1989); or ❑ § 121(f)2 Outside Air Certification: The system shall provide the minimum outside air as shown on the mechanical drawings, and shall be measured and certified by the installing licensed C-20 mechanical contractor and certified by (1) the design mechanical engineer, (2) the installing licenced C-20 mechanical contractor, or (3) the person with overall responsibility for the design of the ventilation system; or § 121(f)3 Outside Air Measurement: The system shall be equipped with a calibrated local or remote device capable of measuring the quantity of outside air on.a continuous basis and displaying that quantity on a readily accessible display divice; or § 1,21 (f)4 -Another method approved by the Commission. Service Water Heating Systems F—]' § 113(b)2 If a circulating hot water system is installed, it shall have a control capable of automatically turning off the circulating pump(s) when hot water is not required. § 113(c) Lavatories in restrooms of public facilities shall be equipped with controls to limit the outlet temperature to 110 degrees F. EnergyPro By Energysoft User Number: User Job Number: Page: 11 of 11