07-2269 (SFD)I
P.O. BOX 1504 ,
78-495 CALLE TAMPICO
LA QUINTA, CALIFORNIA 92253
Application Number 07' 00002269
Property Address: 57505 ROSEWOOD CT
APN: 762-240-011-1 -32279 -
Application description: DWELLING - SINGLE FAMILY
Property Zoning: LOW DENSITY RESIDENTIAL
Application valuation: 208902
Applicant:
� �4urKrw
BUILDING & SAFETY DEPARTMENT
BUILDING PERMIT
Owner: '
STANDARD PACIFIC
15326 ALTON PKWY
DETACHED IRVINE, CA 92618
(949)789=1600
cr,hitect or Engineer:
LICENSED CONTRACTOR'S DECLARATION
I hereby affirm under penalty of perjury th4irf-a-m—hensed under provisions of Chapter 9 (commencing with
Section 7000) of Division 3 of the Buri ro sio License is in full force and effect.
i �coneo,CUec B� _ / Y o o u. S
Date:
I hereby affirm under penalty of perjury that.) am exempt from the Contractor's State License Law for the
following reason (Sec. 7031 .5, Business and Professions Code: Any'city or county that requires a permit to
construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the
permit to file a signed statement that. he or she is licensed pursuant to the provisions of the Contractor's State
License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or
that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by
any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).:
(_) I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and
' the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The
Contractors' State License Law does not -apply to an owner of property who builds or improves thereon,
and who does the work himself or herself through his or her own employees, provided that the
improvements are not intended or offered for sale. If, however, the building or improvement is sold within
one year of completion, the owner -builder will have the burden of proving that he or she did not build or
improve for the purpose of sale.). '
(_) I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec.
7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of
property who builds or improves thereon, and who contractsfor the projects with a contractor(s) licensed,.
pursuant to the Contractors' State License Law.).
(_ 1 I am exempt under Sec. , B.&P.C. for this reason
Date: Owner:
CONSTRUCTION LENDING AGENCY ,
I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the
work for which thispermit is issued (Sec. 3097, Civ. C.).
Lender's Name:
Lender's Address:
LQPERMIT
Contractor:
STANDARD PACIFIC
15326 ALTON PKWY
IRVINE, CA 92618
(949)789-1600
Lic. No.: 641665
VOICE (760) 777-7012
FAX (760) 777-7011
INSPECTIONS (760) 777-7153
Date- 8/09/07
COACHELLA VLY.
WORKER'S COMPENSATION DECLARATION
I hereby affirm under penalty of perjury one of the following declarations:
_ I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided
for by Section 3700 of the Labor Code, for the performance of the work for which this permit is
-P issued.
have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor
Code, for the performance of the work for which this permit is issued. My workers' compensation
insurance carrier and policy number are:
Carrier SEA BRIGHT INS Policy Number BB1070237
_ I certify that, in the performance of the work for which this permit is issued, I shall not employ'any
person in any manner so as to come bject to the workers' compensation laws of California,
and agree that, if I should he or vers' co sation provisions of Section
00 of the Labor C tall forthwith c m pr isions. .
D� �/ pplicant:
WAR ING: AILURE TO SECURE WORK COMPENSATI N C ER IS UNLAWFUL, AND SHALL
SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL. FINES UP TO ONE HUNDRED THOUSAND
DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN
SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES.
• APPLICANT ACKNOWLEDGEMENT
IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the
conditions and restrictions set forth on this application.
1 . Each person upon whose behalfthisapplication is made; each person at whose request and for
whose benefit work is performed under or pursuant to any permit issued as a result of this application,
the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City
of La Quinta, its officers, agents and employees for any act.or omission related to the work being
performed under or following issuance of this permit.
2. Any permit issued as a result of this application becomes null and void if work is not commenced
. within 180 days from date of issuance of suc rmit, cessation of work for 180 days will subject
permit to cancellation.
I certify that 1 have read this application and s ha he above inform do is ct. I agree to comply with all
• city and county ordinances and state laws relating Iii a re b a representatives
Of this y to nter upon the above-mentioned roperty rinspec
ate: %/ Signature scant or Age '
Application Number
. . . 07-00002269
Permit
BUILDING PERMIT
Additional desc..:.
Permit Fee
1021.00 Plan Check Fee
663.65
Issue Date
Valuation . . . .
208902
Expiration Date
2/05/08
Qty Unit Charge
Per
Extension
BASE FEE
639.50
'
109..00 3.5000
THOU BLDG 100,001-500,000.
381.50
Permit.
MECHANICAL
Additional desc
Permit Fee . . .
101.00 Plan Check Fee
25.25
_
Issue Date
Valuation
0
Expiration Date .
2/05/08
Qty Unit Charge
Per
Extension
BASE FEE
15.00_
2.00 9.0000
EA MECH FURNACE <=100K
18.00
2.00 9.0000
EA. MECH B/C <=3HP/100K BTU
18.00
6.00 6.5000
EA MECH VENT FAN
39.00
1.00 11.0000
EA MECH DOMESTIC INCINERATOR
11.00
Permit . . .
ELEC-NEW RESIDENTIAL
Additional desc..
Permit Fee . . . .
146.32 Plan Check Fee '.
36.58
Issue Date . _ . .
Valuation
0
Expiration Date
2/05/08
Qty Unit Charge
Per -
Extension
BASE -FEE
15.00
3380.00 .0350
ELEC NEW RES - 1 OR 2 FAMILY
' 118•.30
651.00 .0200
-----------------------------------------------------------------------------
ELEC GARAGE OR NON-RESIDENTIAL
13.02
Permit
PLUMBING
Additional desc .
'Permit Fee
-191.25 Plan Check Fee
47.81 .
Issue Date
Valuation
- 0
Expiration Date
2/05/08
Qty Unit Charge.
Per
Extension
BASE FEE
15.00
20.00 6.0000
EA PLB FIXTURE
120.00
1.00., 15.0000
EA PLB BUILDING SEWER
15:00
LQPERMIT
..
i
LQPERMIT
-Application Number
. . . . 07-00002269
Permit . . . . . PLUMBING
Qty Unit Charge
Per
Extension
1.00. 7.5000
EA PLB WATER HEATER/VENT
7.50
1.00 3.0000
EA PLB WATER INST/ALT/REP
3.00
1.00 . 9.0000
EA PLB LAWN SPRINKLER:SYSTEM
9.00
" 9.00 .7500
EA PLB GAS PIPE >=5
6.75
1.00 15.0000
EA, PLB GAS METER
15.00
Permit GRADING PERMIT
Additional desc .
Permit Fee
15.00 Plan Check Fee
.00
Issue Date . . . .
0
Expiration Date
_Valuation
2/05/08
Qty Unit Charge.
Per
Extension
BASE FEE.
15.00
--------------------------- -------------------------------------------
Special Notes and Comments -
SFD - LOT 1, PLAN 1SC,
INCLUDES
COURTYARD FIREPLACE, 3380 SF. PERMIT
DOES NOT INCLUDE POOL,
SPA, BLOCK WALLS
OR DRIVEWAY APPROACH.
2001 CBC, CMC,.
CPC,,2004 CEC, 2005 ENERGY CODES
-----------------------
Other Fees . . . . .
Other
----------------------
--------------------------
.- ART IN PUBLIC PLACES -RES
--
22.25 .
DIF COMMUNITY CENTERS -RES
74.00
DIF CIVIC CENTER - RES
995.00'
ENERGY REVIEW FEE
66.37
DIF FIRE PROTECTION -RES
140.00
GRADING PLAN CHECK FEE
.0.0
DIF LIBRARIES _ RES
355.00
DIF PARK MAINT FAC - RES
22.00
DIF PARKS/REC - RES
892.00
REPLACEMENT INSP CARD
15.00
STRONG MOTION (SMI) - RES
20.89
DIF STREET MAINT FAC -RES
67.00
DIF TRANSPORTATION - RES
1930.00
Fee summary Charged
---=------------- ----------
Paid. Credited
----- ----- ---------- ----------
Due
F( xK lit- F'Qe Total
1474,57 , 00 , 00
1474,57-
474,57-
Plan
P1an Check Total
773.29 .00 .00
773.29
Other;Pee Total
4599.51 .00 .00
4599.51
Grand Total
6847.37 .00 .00
6847.37
e
ENGINEERING, INC.
structural consulting and design
July 9, 2008
Standard Pacific of Coachella Valley
PMB #303
1717 E Vista Chino Rd, Ste A7
Palm" Springs, CA 92262
ATTN: Troy Hefner
WE: Palo Verde
Structural, Observation_'
Lot 1-ISC� 57-505 Rosewood Court
Dear Mr. Hefner,
jn accoidance.with your request our office performed a site observation of the Palo Verne project.in order '
to observe the framing to date of the above mentioned lot and have found it in general conformance with`
the plans: The site visit consisted of a walk through observation of the construction tha: was visible: No
dismantling of construction' or testing was performed to verify construction that was noi: readily visible.
• The observation does not relieve the contractor and builder from making sure that the construction
conforms to the city approved construction documents. If you should have any questions, please contact
this office:
Sincerely
Richar reitas, P.E.
' -cco. 4§072- -T 61
President
307 N. Berry Street
Brea, California 92821
'9
phone (714)256.2722 fax (714)256.9182
!CERTIFICATE OF FIELD VERIFICATION
ECT AND DIAGNOSTIC TESTING (TD 8 TXT
PROJINFO N
Project TiUs. Pato verde CZ:
Project Address: La Quinta
Builder Nast w Standard Pacific
Builder Contact: Trey Voice * :
ptF # Tract # 32279 Vofoe # : 760498-2609
2B
Dion'*. 1
kddress: 57 -505 -Rosewood Cpm- i
;ontfrtioned Floor Area: uare Feet
1ERS TER HERS R VIDER INFORMATION
OEM Rater: SON Johnson Jame Callen
'ern = CCMJ614037 Jame Carden
IERS Firm: MPH
ddb: 2208 S. Fairview Road, Santa Voice #: 714-641-3983
ERS Provider: CHEERS. Ca 82704
ERS Address; 9400 Twanga Canyon Blvd.. Ch Voice # : 800-4243977
IERS TER COMPLIANC STATEM a�"O 81311
he house / unit was:
Tested / Verfled
K Approved as a part of sample, but was not Tested /Verified
No Diagnostic Credits have been taken (visual inspections only)
The installer has nrovirtcw s .. -.. --
Air Dig& pn•.. I *Wit vucw
Where Doth system is '=idly Ducted (deem,etsi, ductboard or flex dud)
ked ft1bber adhesive duct tape is installed, maO
cloth badwd,bber adhesive duct tape to seal leeks at the c and connertionsmwbands are used in combination with
COOLING
0.7 x Floor Area x Nominal Cooling
0.5 x Floor Area x 0ma
.06) for ate ton one 8 throughro15
400 x (Cooling mie51 through 78,18
+red Fan FT in Nonal Tong) x (0,06)
t PmmrizWon Test Results (CFM 0 25 PA)
K Test Leakage f Fan Flow = % Leakage
ek Box for Puss Or Fail (Pass 6% or Legs)
,T-24 Comp6once Credit was Taken for TXV (Installed _ Y! N)
Mmr_
Heating Capacity in Thousands of Output M per hour
21.7 x Heating Capadty in "Ura of Out 9711 Per hour
21.7 x (Heat r>g Cap. In 1000's of Output BTU per hour) x (0.05)
Duct PreasurtWon Test Results (CFM @ 25 PA)
100 x Test Leakage / Fan Flow = % Leakage
rasa or ran trans = oyb or Law)
ft? RA M, Appendfx RL
R2bM CoMytrig Signature
Date 11/1` 1=08
F2001-02 (4.02) Action NOW T-24 CF-4itMem.xis
PAGE Zit 1 RM AT 111132008 t.35:22 AM radc Sha &d rhejt 80:890A101N DNISM CS®IUM139HIMTION hum ):01.00
gel
CF -4R Page 1 of 1
Southwest Inspection and Testing, Inc.
441 Commercial Way, La Habra, CA 90631
(562) 941-2990 • (714) 526-8441 • Fax (562) 946-0026
REGISTERED INSPECTORS'S DAILY REPORT*
SWIT Job No.
Date
9-4;-018
TYPE OF
INSPECTION
REQUIRED
59 Reinforced Concrete ❑ Strdctural Steel Assembly ❑ Quality Control
❑ Post Tensioned Concrete ❑ Fire Proofing ❑ Other
❑ Reinforced Masonry ❑ Asphalt
Job Address�
5
City
a.
Job Name
Permit No.r���
DD
Is ued By
Type of Structure h
Architect ,
Material Description (type, grode, source)
Engineer
Contractor
Inspe r(s) No a
Subcontracto
TESTS PERFORMED
TYPE OF SAMPLE
SLUMP
QUANTITY IN SET
ADDITIONAL REMARKS ON SAMPLES
41/
A -j
of
INSPECTION SUMMARY —
LOCATIONS OF WORK INSPECTED, TEST SAMPLES TAKEN, WORK REJECTED, JOB PROBLEMS, PROGRESS, REMARKS, ETC.
INCLUDES INFORMATION ABOUT - AMOUNTS OF MATERIAL PLACED OR WORK PERFORMED, NUMBER, TYPE & IDENT. NO'S OF
TEST SAMPLES TAKEN: STRUCT. CONNECTIONS (WELD MADE H.T. BOLTS TORQUED) CHECKED, ETC.
065-evveA
Q fo a i d r 1
I
V
4 14 A As V -
-7•SoS o =o -?142
K st
o aJAI-La LU411z06--160,4 o
6-7pivsle:wodd C�ti�,cr-� �e%c3woiS-JO05'
CERTIFICATION OF COMPLIANCE
I HEREBY CERTIFY THAT I HAVE OBSERVED TO THE BEST OF MY KNOWLEDGE ALL OF THE ABOVE REPORTED
WORK UNLESS OTHERWISE NOTED. I HAVE FOUND THIS WORK TO COMPLY WITH THE APPROVED PLANS,
SPECIFICATIONS-ey, AND APPLICABLE SECTIONS OF THE GOV RNING BUILDING LAWS.
r '
SIGNATU E OF EGISTERED INSPECTOR
l!J 3151-I- /4'q
SPECIALTY NO. AGENCY
CONTINUED ON NEXT PAGE ❑ FAGE OF
TIME IN I TIME OUT I REG. HOURS I O.T. HOURS I CYLINDERS
4630 1 IVIG 18 I I+
All inspections based on a minimum of 4 hours and over 4 hours - 8 hour
minimum.
Approved by
Superintendent
WHITE - OFFICE COPY, CANARY - ACCOUNTING COPY, PINK - INSPECTOR'9'COPY, GOLDENROD - JOB SITE COPY
J` Southwest Inspection and Testing, Inc.
441 Commercial Way, La Habra, CA 90631
(562) 941-2990 9 (714) 526-8441 9 Fax (562) 946-0026
REGISTERED INSPECTORS'S DAILY REPORT
SWOITJobONo.
9t- 09
TYPE OF
INSPECTION
REQUIRED
(X Reinforced Concrete ❑ Strcictural Steel Assembly ❑ Quality Control
❑ Post Tensioned Concrete ❑ Fire Proofing ❑ Other
❑ Reinforced Masonry ❑ Asphalt
Job Address
,,1, lcwn City
Job Name
Permit o. �e
J0610 4.00� s
Iss ed By
Type of Structur. h
Architect
Material Description (tyJple, grade. so rce)
Engineer
Contractor S
OL
i
Inspector( ame
DA 0131"QLr
Subcontractor
TESTS PERFORMED
TYPE OF SAMPLE
SLUMP
QUANTITY IN SET
ADDITIONAL REMARKS ON SAMPLES
INSPECTION SUMMARY
— LOCATIONS OF WORK INSPECTED, TEST SAMPLES TAKEN, WORK REJECTED, JOB PROELEMS, PROGRESS, REMARKS, ETC.
INCLUDES INFORMATION ABOUT - AMOUNTS OF MATERIAL PLACED OR WORK PERFORMED, NUMBER, TYPE & IDENT. NO'S OF
TEST SAMPLES TAKEN: STRUCT. CONNECTIONS (WELD MADE H.T. BOLTS TORQUED) CHECKED, ETC.
0
fsN
A= wall 6011,vt
e- I i
� � 1
s� �s-ost
��
n -s ux-Y
r i AIA0121EATS g 1 f
CERTIFICATION OF COMPLIANCE
I HEREBY CERTIFY THAT I HAVE OBSERVED TO THE BEST OF MY KNOWLEDGE ALL OF THE ABOVE REPORTED
WORK UNLESS OTHERWISE NOTED. I HAVE FOUND THIS WORK TO COMPLY WITH THE APPROVED PLANS,
SPE ICATIONS OF THE GOVERNING BUILDING LAWS.
SIGNATUR(OFR ISTERED INSPECTOR
SPECIALTY NO. AGENCY
CONTINUED ON NEXT PAGE U FAGE OF
TIME IN I TIME OUT I REG. HOURS I O.T. HOURS I CYLINDERS
L 1 -.0 0 1 12) 0,0 11
All inspections based on a minimum of 4 hours and over 4 hours 8 hour
minimum.
Approved by
Project Superintendent
WHITE - OFFICE COPY, CANARY - ACCOUNTING COPY, PINK - INSPECTOR'S COPY, GOLDENROD - JOB SITE COPY
SOUTHWEST INSPECTION AND TESTING INC.
441 COMMERCIAL WAY
LA HABRA, CA 90631-6168
562-941-2990 714-526-8441 Fax -562-946-0026
-------------------------------
FIELD DATA ON TEST SPECIMENS
--- ASTM C31, C138, C143, C172, C173, C231, C1064 ---
CONCRETE: X GROUT: MORTAR: SHOTCRETE: CORES: GUNITE:
ADDRESS: 57-505 ROSEWOOD CT. LA QUINTA JOB #: 60280 DATE: 10/18/2007
JOB NAME: PALO VERDE/TR#32279/PH#2A PERMIT #: 07-2269 ISSUED BY: LA QUINTA
ARCHITECT: BASSENIAN & LAGONI ENGINEER: R.G.F.
CONTRACTOR: STANDARD PACIFIC SUB CONTRACTOR: DIAZ CONCRETE
-----------_-----------------------------------------------
LOCATION IN STRUCTURE: FOOTINGS/ LOT#1
-----------------------------------------------------------
CONCRETE SUPPLIER: SUPERIOR PLANT: COACHELLA MIX #: D83625P
TYPE OF CEMENT.: V ADMIXTURE: TICKET #: 21959
SLUMP : 4" WATER ADDED: 0 GAL. AIR TEMP: 72'F
CONCRETE TEMP: 70 F MIXING TIME: 45 MIN. TIME CAST: 8:00
------------------------------------------------------------
DATE CAST: 9/19/2007 RECEIVED AT LAB: 9/20/2007
-------------------------------------------------------------
SPECIMENS MADE BY: BILL LA GRANDE SPECIFIED PSI: 4000
------------------------ ---�*-
FIELD IDENTIFICATIONI A I B I C I D I E
--------------------------------------------------------------
LAB IDENTIFICATION : 709859 : 709859 : 709859 : 709859
------------------------------------------------------------------
AGE DAYS 7 28 : 28 : H O L D
DATE TEST 9/26/2007 10/17/2007: 10/17/2007:
SIZE -IN. 4 X 8 4 X 8 4 X 8
AREA-SQ.IN. 12.57 12.57 12.57
CRUSH LOAD -LBS 47600 70130 73160
COMP-STR.-PSI. 3790 5580 5820
I. H/D
CORR FACTOR
CORR.STR.-PSI
TIME TESTED
BREAK TYPE
C.T.M. USED FORNEY FORNEY FORNEY
-----------------------------------------
REMARKS:
------------------------------------------------------------
ASTM C39, C174, C192, C470, C617, C42
COMPLIES: X DOES NOT COMPLY:
----------------------------------------------------------
THIS REPORT SHALL NOT BE REPRODUCED, EXCEPT IN FULL WITHOUT THE APROVAL OF SITI
---------------------------------------------------------
RESPECTFULLY SUBMITTED
SOUTHWEST INSPECTION AND TESTING
SAMPLES CAST BY OTHERS:
LAB. MAN
ASTM C39 BREAKS A= cone B= cMrne and split C= cone D=shear E=columnar
SOUTHWEST INSPECTION AND TESTING INC.
441 COMMERCIAL. WAY
LA HABRA, CA 90631-6168
562-941-2990 714-526-8441 Fax-562-946-0026
FIELD DATA ON TEST SPECIMENS
--- ASTM C31, C138, C143, C172, C173, C231, C1064 --
CONCRETE: X GROUT: MORTAR: SHOTCRETE: CORES: . GUNITE:
ADDRESS: 57-535 ROSEWOOD CT. LA QUINTA JOB #: 60280 DATE: 10/18/2007
JOB NAME: PALO VERDE/TR#32279/PH#2A PERMIT ##: 07-2276 ISSUED BY: LA QUINTA
ARCHITECT: BASSENIAN & LAGONI ENGINEER: R.G.F.
CONTRACTOR: STANDARD PACIFIC SUB CONTRACTOR: DIAZ CONCRETE
----------------------------------
------------------
LOCATION IN STRUCTURE: FOOTINGS/ LOT#2
--------------------------------------
CONCRETE SUPPLIER: SUPERIOR PLANT: COACHELLA MZX #: D83625P
TYPE OF CEMENT : V ADMIXTURE: TICKET #: 21955
SLUMP : 4" WATER ADDED: 0 GAL. AIR TEMP: 70 F
CONCRETE TEMP: 68.F MIXING TIME: 40 MIN. TIME CAST: 7:35
--------------
-------------------
DATE CAST: 9/19/2007 RECEIVED AT LAB: 9/20/2007
--------------------------------
SPECIMENS MADE BY: BILL LA GRANDE SPECIFIED PSI: 4000
-----------------------------------------
----------
FIELD IDENTIFICATIONI A I g I C I D I E
----------------------------
----------------------
LAB IDENTIFICATION 709860 709860 : 709860 709860
------------------------------
----------------------
AGE DAYS 7 28 28 H 0 L D
DATE TEST 9/26/2007 10/17/2007: 10/17/2007:
SIZE -IN. 4 X 8 4 X 8 4 X 8
AREA-SQ.IN. 12.57 12.57 12.57
CRUSH LOAD -LBS 48900 76390 78930
COMP-STR.-PSI. 3890 6080 6280
I H/D
CORK FACTOR
CORR.STR.-PSI
TIME TESTED
BREAK TYPE
C.T.M. USED FORNEY FORNEY FORNEY
-----------------------------------------
------------
EMARKS:
------------------------------------------
ASTM C39, C174, C192, C470, C617, C42
COMPLIES: X DOES NOT COMPLY:
---------------------------
-------------------------
THIS REPORT SHALL NOT BE REPRODUCED, EXCEPT IN FULL WITHOUT THE APROVAL OF SITI
-----------------------------------------
RESPECTFULLY SUBMITTED
SAMPLES CAST BY OTHERS:
SOUTHWEST INSPECTION AND TESTING
LAB. MANA
ASTM C39 BREAKS A= cone B= corAt and split C= cone D=shear E=columnar
SOUTHWEST INSPECTION AND TESTING INC.
441 COMMERCIAL WAY
LA HABRA, CA 90631-6168
562-941-2990 714-526-8441 Fax -562-946-0026
-------------------------------
FIELD DATA ON TEST SPECIMENS
--- ASTM C31, C138, C143, C172, C173, C231, C1064 ---
CONCRETE: X GROUT: MORTAR: SHOTCRETE: CORES: GUNITE:
ADDRESS: 57-565 ROSEWOOD CT. LA QUINTA JOB #: 60280 DATE: 10/18%2007
JOB NAME: PALO VERDE/TR#32279/PH#2A PERMIT #: 07-2277 ISSUED BY: LA QUINTA
ARCHITECT: BASSENIAN & LAGONI ENGINEER: R.G.F.
CONTRACTOR: STANDARD PACIFIC SUB CONTRACTOR: DIAZ CONCRETE
---------------------------------------
LOCATION IN STRUCTURE: FOOTINGS/ LOT#3
-----------------------------------7-------------
CONCRETE SUPPLIER: SUPERIOR IPLANT: COACHELLA MLIX #: D83625P
TYPE OF CEMENT : V ADMIXTURE: TICKET #: 21939
SLUMP : 4" WATER ADDED: 0 GAL. AIR TEMP: 80 F
CONCRETE TEMP: 74 F MIXING TIME: 35 MIN. TIME CAST: 10:15
---------------------------
DATE CAST: 9/18/2007 RECEIVED AT LAB: 9/19/2007
------------------------------------------------------
SPECIMENS MADE BY: BILL LA GRANDE SPECIFIED PSI: 4000
-------------------------------------------------------
FIELD IDENTIFICATION A I B I C I D I E
-------------------------------------------------------
LAB IDENTIFICATION : 709861 : 709861 : 709861 : 709£61
--------------------------------------------------------
AGE DAYS 7 28 : 28 : H O L D
DATE TEST 9/25/2007 10/16/2007: 10/16/2007:
SIZE -IN. :.4 X 8 4 X 8 4 X 8
AREA-SQ.IN. 12.57 12.57 12.57
CRUSH LOAD -LBS 44070 62500 63900
COMP-STR.-PSI. 3500 4970 5080
I H/D
CORR FACTOR
CORR.STR.-PSI
TIME TESTED
BREAK TYPE
C.T.M. USED FORNEY FORNEY FORNEY
-------------------------------------------------
REMARKS:
--------------------- - ----------------------------
ASTM C39, C174, C192, C470, C617, C42
COMPLIES: X DOES NOT COMPLY:
---------------------------------------
THIS REPORT SHALL NOT BE REPRODUCED, EXCEPT IN FULL WITHOUT THE APROVAL OF SITI
------------------------------------------------
RESPECTFULLY SUBMITTED
SOUTHWEST INSPECTION AND TESTING
SAMPLES CAST BY OTHERS:
R.0
LAB. MAN
ASTM C39 BREAKS A= cone B= cone and split C= cone D=shear E=columnar
SOUTHWEST INSPECTION AND TESTING INC.
441 COMMERCIAL WAY
LA HABRA, CA 90631-6168
562-941-2990 714-526-8441 Fax-562-946-0026
FIELD DATA ON TEST SPECIMENS
--- ASTM C31, C138, C143, C172, C173, C231, 01064 ---
CONCRETE: X GROUT: MORTAR: SHOTCRETE: CORES: GUNITE:
ADDRESS: 57-595 ROSEWOOD CT. LA QUINTA JOB #: 60280 DATE: 10/18/2007
JOB NAME: PALO VERDE/TR#32279/PH#2A PERMIT #: 07-2278 ISSUED BY: LA QUINTA
ARCHITECT: BASSENIAN & LAGONI ENGINEER: R.G.F.
CONTRACTOR: STANDARD PACIFIC SUB CONTRACTOR: DIAZ CONCRETE
--------------------------7------------
LOCATION IN STRUCTURE: FOOTINGS/ LOT#4
---------------------------------
CONCRETE SUPPLIER: SUPERIOR PLANT: COACHELLA NIX #: D836'25P
TYPE OF CEMENT : V ADMIXTURE: TICKET #: 21927
SLUMP : 4" WATER ADDED: 0 GAL. AIR TEMP: 70,F
CONCRETE TEMP: 68 F MIXING TIME: 45 MIN. TIME 'AST: 7:40
------------------=---------------
DATE CAST: 9/18/2007 RECEIVED AT LAB: 9/19/2007
----------------------------------------------------
SPECIMENS MADE BY: BILL LA GRANDE SPECIFIED PSI: 4000
--------------
----------------------------------
FIELD IDENTIFICATIONI A I B I C I D I E
---------------------------------------------------
LAB IDENTIFICATION : 709862 : 709862 : 709862 : 709862
---------------------------------------------------
AGE DAYS 7 28 : 28 : H O L D
DATE TEST 9/25/2007.: 10/16/2007: 10/16/2007:
SIZE -IN. 4 X 8 4 X 8 4 X 8
AREA-SQ.IN. 12.57 12.57 12.57
CRUSH LOAD -LBS 42670 63500 64800
COMP-STR.-PSI. 3395 5050 5155
I H/D
CORR FACTOR
CORR.STR.-PSI
TIME TESTED
BREAK TYPE
C.T.M.' USED FORNEY FORNEY : FORNEY
--------------------------------------------
REMARKS: -
--------------------------------------------------
ASTM C39, C174, C192, C470, C617, C42
COMPLIES: X DOES NOT COMPLY:
--------------------------------------
THIS REPORT SHALL NOT BE REPRODUCED, EXCEPT IN FULL WITHOUT THE APROVAL OF SITI
-----------------------------------------------
RESPECTFULLY SUBMITTED
SOUTHWEST INSPECTION AND TESTING
SAMPLES CAST BY OTHERS:
R
LAB. MAN
ASTM C39 BREAKS A= cone B= co..e and split C= cone D=shear E=columnar