Loading...
07-2279 (SFD)-P.O. BOX 1504 78-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 Tiht 4 4 Q" BUILDING & SAFETY DEPARTMENT BUILDING PERMIT Application Number: ' 07-00002279 Property Address: 57600 ROSEWOOD CT APN: 762-2407011-27 -32279 - Application description: DWELLING - SINGLE FAMILY• DETACHED Property Zoning: LOW-DENSITY RESIDENTIAL Application valuation: 221901 Applicant: rchi4z tett or.Engineer:, LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury the m derp of Chapter 9 (commencing with Section 7000) of Division 3 of the Busme _ ro sio Is o nd License is in full force and effect. License lass: Li 6 5 ' /Date: ntractor: - OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the following reason (Sec. 7031 .5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the ' permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: (_) I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that Fie or she did not build or improve for the.purpose of sale.). (_ 1 I; as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with o contractor(s) licensed pursuant to the Contractors' State License Law.). (_ 1 I am exempt under Sec. , B.&P.C. for this reason Date: Owner: CONSTRUCTION LENDING AGENCY-) I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Name: I' Lender's Address: LQPERMIT Owner: STANDARD PACIFIC 15326 ALTON PKWY IRVINE, CA 92618 (949)789-1600 VOICE (760) 777-7012 FAX (760) 777-7011 INSPECTIONS (760) 777-7153, COACHELLA VLY Contractor: STANDARD PACIFIC CORP 15326 ALTON PKWY IRVINE, CA 92618 (949)789-1600 Lic. No.: 641665 Date: 8/09/07 ----------------------------------------------- WORKER'S COMPENSATION DECLARATION hereby affirm under penalty of perjury one of the following declarations: - 1 have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance'of the work for which this permit is issued. I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier SEA BRIGHT INS Policy Number BB1070237 I certify that, in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as t ome subject the workers' compensation laws of California, and agree that, if I should ecome bjest t work rs' compensation provisions of Section 00 of the Labor Co , I s se provisions. a/D te: �,LURET�SEaCURE t: WARNN WOCSMTO NAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN - SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT Application is hereby made to the Director of Building and Safety for a.permit subject to the conditions and restrictions set forth on this application. 1 . Each persuii upun whose behalf this application Is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application, the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such cion of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that t ab is c rrec comply with all city and county ordinances and state laws relating to buildi natives oI his coo ty to ter upon the above-mentioned propert for inspecu urp� es Date: #y/0;'ra ture (Applicant or Agent): LQPERMIT _ Application Number 07-00002279 ' Permit . . . . . BUILDING PERMIT Additional desc . -Permit Fee . . 1066.50 Plan Check Fee 173.31 Issue Date Valuation . . . . 221901 Expiration Date 2/05/08 Qty Unit Charge Per Extension BASE FEE 639.50 122.00 3.5000 ---------------------------------------------------------------------------- THOU BLDG.100,001-500,000 427.00 Permit . . . MECHANICAL Additional desc . Permit Fee 103.00 Plan Check Fee 6.44 Issue Date Valuation . . . . 0 Expiration Date 2/05/08 Qty Unit Charge 'Per Extension BASE FEE 15.00. 00 9.0000 EA MECH FURNACE -<=100K 18.00 ''2. 2.00 9.0000 EA MECH B/C <=3HP/100K BTU 18.00 7.00 6.5000 EA MECH VENT FAN 45.50 1.00 6.5000 EA, MECH EXHAUST HOOD 6.50 Permit ELEC-NEW RESIDENTIAL Additional desc " Permit Fee 151.30 Plan Check Fee 9.46 Issue Date . . . Valuation 0 Expiration Date 2/05/08 Qty. Unit Charge Per, Extension BASE FEE 15.00 3544:00 .0350 ELEC NEW RES - 1 OR 2 FAMILY 124.04 613.00 .0200 ELEC GARAGE OR NON-RESIDENTIAL -------------- 12.26 Permit. ermitPLUMBING Additional desc . Permit Fee- 202.50 Plan Check Fee 12.66_, Issue Date Valuation 0 Expiration Date 2/05/08 Qty Unit'Charge Per Extension BASE FEE 15.00 22.00 6.0000 EA PLB FIXTURE 132.00 •1.00. 15.0000 EA PLB BUILDING SEWER 15.00 LQPERMIT LQPERMIT .. Application Number 07-00002279 Permit PLUMBING Qty Unit Charge Per Extension 1.00 7.50'00 EA PLB WATER HEATER/VENT 7.50 1.00 1.0000 EA_ PLB WATER INST/ALT/REP 3.00 1.00 .9.0000 EA PLB LAWN SPRINKLER SYSTEM 9.00 8.00 .7500 EA PLB GAS -PIPE >=5 6'.00 P 1.00 15..0000 EA PLB.GAS METER 15.00 Permit. . . GRADING PERMIT Additional desc Permit Fee . . . . 15.00 Plan Check Fee .00 Issue Date . . . Valuation 0 Expiration Date 2/05/08 Qty. Unit Charge Per Extension BASE FEE 15.00 ---------------------------------------------------------- Special Notes and Comments SFD - LOT 27, PLAN 2SC, 3544 SF. PERMIT DOES NOT INCLUDE POOL, SPA, BLOCK WALLS OR DRIVEWAY APPROACH. 75% ` REDUCTION TO PLAN CHECK FEES DUE TO MULTIPLE ISSUANCE OF SAME PLAN TYPE, 2001 CBC, CMC, CPC, 2004 CEC, 2005 ENERGY CODES -----------------------.-------------------------------------- Other Fees . . . . . . . . . ART IN PUBLIC PLACES -RES 54.75 DIF COMMUNITY CENTERS -RES 74.00 DIF CIVIC CENTER '- RES 995.00 ENERGY REVIEW FEE 17.33' DIF FIRE PROTECTION -RES 140.00 GRADING PLAN CHECK FEE .00 - DIF LIBRARIES - RES 355.00 DIF PARK MAINT FAC - RES 22.00 DIF PARKS/REC - RES- 892.00 REPLACEMENT INSP CARD 15.00 STRONG MOTION (SMI).- RES 22.19• DIF STREET MAINT FAC -RES 67.00 DIF TRANSPORTATION - RES 1930:.0.0. Fee summary Charged Paid Credited Due -------- ----------- ---------- ---------- Permit Fee Total - 1538.30 .00 .00 1538.30 Plan Check Total 201.87 00 00 201.87 Other Fee Totdl 4584.27 .00 .00 4584.27 LQPERMIT .. ENGINEERING, INC. structural consulting and design April -15, 2008 . Standard Pacific of Coachella Valley ; PMB #303 1717 E Vista Chino Rd, Ste A7 Palm Springs, 'CA 92262 ATTN: Troy Hefner RE: Palo Verde Structural Observation Lot 27-2SC 57-600 Rosewood Court Dear Mr. Hefner, In accordance with your request our office performed a site observation of the Palo Verde project in order to observe the framing to date of the above mentioned lot and have found it in general conformance with the plans. The site visitconsisted of a walk through observation of the construction that was visible. No dismantling of.construction or testing was performed to verify construction that"was no. readily visible. The observation does not relieve the contractor and builder from making sure that the construction conforms'to the city approved construction documents. If you should have any questions, please contact this office. Sincerely, " OQ�pFfS"��Nq - Richard G. Freitas, P.E. ¢ No. C 072 v' rn ' President u1 �. rn ' OF C �L1f0 4 307 N. Berry Street Brea, California 92821 phone (714)256.2722 fax (714)256.9182 11 INSTALLATION CERTIFICATE (Page 3 of 13) CF -6R r% I i ,.i% Permit Number Site Address DUCT LEAKAGE, AND DESIGN DIAGNOSTICS DUCT LEAKAGE REDUCTION Pressurization Test Results(CFM Q 25 PA) g (CFM) 5 Test Leakage CFM 5 Fan Flow 'If Fan Flow is Calculated as 400 cfm/ton x number of tons, or as 21.7 x Heating Capacity in Thousands of Btu/hr, enter calculated value here (o Ob If fan flow is measured, enter measured value here Leakage Fraction = Test Leakage/(Measured or Calculated Fan Flow) _ Pass if leakage fraction 5 0.06 0 ❑ Pass Fail ❑ For AEROSOL TYPE SEALANTS ONLY - The following diagnostic testing was completed: Duct Fan Pressurization at rough -in measured leakage (CFM) CHECK AFTER FINISHING WALL: ❑ Yes ❑ No ❑ Pressure pan test or House pressurization test ❑ Yes ❑ No ❑ Visual Inspection of Duct Connections ❑ ❑ Pass Fail © THERMOSTATIC EXPANSION VALVE (TXV) ❑ Yes ❑ No Thermostatic Expansion Valve is installed and Access is provided for inspection ❑ ❑ Yes is a pass Pass Fail ❑ DUCT DESIGN 1 ❑ Yes ❑ No ACCA Manual D Design calculations have been completed, Duct Design is on the plans and duct installation matches plans. 2. ❑ Yes ❑ No TXV is installed or Fan flow has been verified. If no TXV, verified fan flow matches design from CF -IR. - Measured Fan Flow = ❑ ❑ Yes for both I and 2 is a Pass Pass Fail ❑ I, the undersigned, verify that the above diagnostic test results and the work I performed associated with the test(s) is in conformance with the requirements for compliance credit. [The builder shall provide the HERS provider a copy of the CF -6R signed by the builder employees or sub -contractors certifying that diagnostic testing and installation meet the requirements for compliance credit.] A/f, Tests Signature, Date Installing Subcontractor (Co. Name) OR Performed General Contractor (Co. Name) COPY TO: Building Department HERS Provider (if applicable) Building Owner at Occupancy Compliance Forms August 2001 A-25 INSTALLATION CERTIFICATE (Page 3 of 13) CF -6R r Permit Number Site Address DUCT LEAKAGE AND DESIGN DIAGNOSTICS �I DUCT LEAKAGE REDUCTION Pressurization Test Results (CFM (a3 25 PA) Test Leakage (CFM) �V Fan Flow If Fan Flow is Calculated as 400 cfm/ton x number of tons, or as 21.7 x Heating Capacity in Thousands of Btu/hr, enter calculated value here r_') a o , If fan flow is measured, enter measured value here Leakage Fraction = Test Leakage/(Measured or Calculated Fan Flow) = Pass if leakage fraction <_ 0.06 [� ❑ Pass . Fail ❑ For AEROSOL TYPE SEALANTS ONLY - The following diagnostic testing was completed: Duct Fan Pressurization at rough -in measured leakage (CFM) CHECK AFTER FINISHING WALL: ❑ Yes ❑ No ' ❑ Pressure pan test or House pressurization test ❑ Yes ❑ No ❑ Visual Inspection of Duct Connections ❑ ❑ Pass Fail ® THERMOSTATIC EXPANSION VALVE (TXV) V Yes ❑ No Thermostatic Expansion Valve is installed and Access is ❑ provided for inspection KI Yes is a pass Pass Fail ❑ DUCT DESIGN 1 ❑ Yes ❑ No ACCA Manual D Design calculations have been - completed, Duct Design is on the plans and duct installation matches plans. 2• ❑ Yes ❑ No TXV is installed or Fan flow has been verified. If no TXV, verified fan flow matches design from CF -IR. Measured Fan Flow = ❑ ❑ Yes for both I and 2 is a Pass Pass Fail Z I, the undersigned, verify that the above diagnostic test results and the work I performed associated with the test(s) is in conformance with the requirements for compliance credit. [The builder shall provide the HERS provider a copy of the CF -6R signed by the builder employees or sub -contractors certifying that diagnostic testing and installation meet the requirements for compliance credit.] Tests Signature, Date Installing Subcontractor (Co. Name) OR Performed General Contractor (Co. Name) COPY TO: Building Department HERS Provider (if applicable) Building Owner at Occupancy Compliance Forms August 2001 A-25 lg� AirnlHq l..nstal.iation Certificate : Residential CF -6R Site Address 57-570 ROSEWOOD COURT Bldg: - Unit: 1. BUILDER INFORMATION Standard Pacific of the Coachella Valley 1717 E. Vista Chino Rd., Suite A7 Palm Springs, CA 92262 PERMIT # SUBDIVISION: Palo Verde CITY: LA QUINTA COUNTY: RIVERSIDE INSTALLING CONTRACTOR: Airplus of California 2. PROJECT INFORMATION DISTRIBUTION TYPE DUCT OR PIPING R-VALI Flexible Ductwork in Flexible Ductwork Will have a Attic and Between Floors R -Value of 4.20 or Better I, the undersigned, verify that the equipment listed in the category above my signature is the equipment installed and that the equipment meets or exceeds the requirements of the Appliance Efficiency Standards. In addition, i have verified that the equipment is equivalent to or more efficient than the equipment specified on the Certificate of Compliance submitted to demonstrate complience with the Energy Efficiency Standards for residential buildings. 3. HEATING INFORMATION HEATING MANUFACT HEATING UNIT ACTUAL EFF. HEATING E UTP HEATING E UTP. MAKE MODEL # AFUE CAPACITY LOAD Furnace-FAU1 Amana GMS80904BXA 80% Furnace-FAU2 Amana GN1S81155CX 80% 4. COOLING INFORMATION , COOLING MANUFACT COMPRESS-QR-- ACTU EFF. COOLING EQUIP COOLING E UTP. MAKE MODEL # 11 SEER CAPACITY LOAD A/C -1 STD' Amana GSC130421A 13 Coil -1 STD' Aspen CP48A3B EER A/G2 STD.' Amana GSC130481A 13 Coil -2 STD Aspen CP60B2X EER The building design heat loss and design heat gain rate have been determined using a method specified in Section 150(h) of the Energy Effidiency Standards, and are two of the criteria used for equipment sizing and selection. 5. THERMOSTATIC EXPANSION VALVE (TXV): Thermostatic Expansion Valve (or Commision approved equivalent) is installed and access is provided for inspection. YES d NO Q N/A Q 6. SUBMITTED BY: Airplus of California 7/30/2008 Signature Installing HVAC Contractor Dace D:1lntraneAwwwrootlCryst*LBPPS=nslCF6R RepoMnn 19AGE 3191RCYD AT 1130120081:53:10 PM (Pacific Daylight Time] "SYR:S90A101611 I DNIS:9630' CSID:' DURATION (mmpss):0248 1 07/31/2006 11:05 7146413989 MPH PAGE 04 CERTIFICATE OF FIELD VERIFICATION AND DIAGNOSTIC TESTING Project 11111w Palo Verde ProjeotAddress; La Quinta Builder Name: Standard Paciflo Builder Contact: Troy Project ID # ; Tract # 32279 Phase #: 2A Lot #: 27 Plan #: 2 Address: 57-600 Rosewood Court Conditioned Floor Area; Square Feet HERS RATER & HERS PROVIDER INFORMATION HERS Rater. Scott Johnson Jayrne Carden Certification #; CCNSJ614037 CCNJC615157 HERS Firm: MPH Address: 2208 S. Fairview Road, Santa Ana, Ca 92704 HERS Provider. CHEERS Ca CA 9131 e house ! unit was: Tested / Verfied Approved as a part of sample, but was not Tested / Verified No Diagnostic Credits have been taken (visual inspections only) The installer has provided a Copy of CF -6R Voice # Voice # 78p -898-25M Voice 9: 714641-3983 Voice #.- 800-42¢3377 -c9 %,ompnance toreait was Taken for Tight Ducts Air Distribution System is Fully Ducted (sheetmstal, ductboard or flex duct) Where Goth backed rubber adhesive duct tape is installed, mastic and drewbands are used in combination with Goth backed, rubber adhesive duct tape t4 seal leaks at the connections. Nominal Cooling Tons 0.7 x Floor Area x (0.06) for Climate Zone 8 through 15 0.5 x Floor Area x (0.06) for Climate Zones 1 through 7 & 16 400 x (Cooling Capacity In Nominal Torts) x (0.06) Measured Fan Flow Duct Pressurization Test Results (CFM ® 25 PA) 100 x Test Leakage / Fan Flow = % Leakage Check Box for Pass or Fail (Pass = 8% or Less) XJT-24 Compliance Credit was Taken for TXV (Installed - Y! N) Heating Capadly in Thousands of Output BTU per hour 21.7 x Heating Capacity in 1000'8 of Output BTU per hour 21.7 x (Heating Cap. in 1000% of output BTU per hour) x (0.06) Duct Pressurizatlon Test Results (CFM @ 25 PA) 100 x Test Leakage 1 Fan Flow = % Leakage rass or ran Wass = tob or Less) for veMlcaton are 8vallbre in Cerb'fyPng Signature Was Rl. t -6V01.02 (4.02) Action Now T-24 CF-4Rmacro.)ft 7/31108 CF -4R Page 1 of 1 PAGE 415 t RM AT 7131!200811:01:51 Wrack Daylight Time)" SYR:S90A101612 t BMW* * CSID:71464139891DURATION (IIItr-Ss):0144 SOUTHWEST INSPECTION AND TESTING INC. 441 COMMERCIAL WAY LA HABRA, CA 90631-6168 562-941-2990 714-526-8441 Fax -562-946-0026 -------------------------------------------------------------------------------- FIELD DATA ON TEST SPECIMENS ' --- ASTM C31, C138, C143, C172, C173, C231, 01064 --- CONCRETE: X GROUT: MORTAR: SHOTCRETE.: CORES: GUNITE: ADDRESS: 57-600 ROSEWOOD CT. LA QUINTA JOB #: 60280 DATE: 7/22/2008 JOB NAME: PALO VERDE PERMIT #: 07-2167 ISSUED BY: LA QUINTA ARCHITECT: ENGINEER: CONTRACTOR: PACIFIC STANDARD' SUB CONTRACTOR: THE MASONRY CO. -------------------------------------------------------------------------------- LOCATION IN STRUCTURE: FOOTINGS/ LOT #'27 RETURN WALL/ S/E CORNER ----------=--------------------------------=------------------------------------ CONCRETE SUPPLIER: ASSOCIATED PLANT: 14IX #: AA1601 TYPE OF CEMENT : V ADMIXTURE:TICKET #: SLUMP :'5" WATER ADDED:_ 0 GAL. AIR TEMP: 87 F CONCRETE TEMP: 89 F' MIXING -TIME: 60 MIN. TIME CAST: 9:50 DATE CAST: 6/13/2008 RECEIVED AT LAB: 6/14/2008 --------------------------------------------------------------------------------- SPECIMENS MADE BY: PHOENIX FEATHEROCK SPECIFIED PSI: 2500 ------------------------------------------------------------------------------ FIELD IDENTIFICATION) A I B I C I D I E ------------------------------------------------------------------------------- LAB IDENTIFICATION 803424 803424 803424 803424 . ------------------------------------------------------------I------------------- AGE.DAYS 7 28 28 H 0 L D DATE'TEST :,6/20/2008 7/11/2008 7/11/2008 SIZE -IN... 4 X 8 4 X 8 4 X 8 AREA-SQ.IN. 12.57 12.57 12.57 CRUSH LOAD -LBS 26200 38260 35920 COMP-STR.-PSI. 2080 3040 2860 H/D CORR FACTOR CORR.STR.-PSI TIME TESTED BREAK TYPE C.T..M . USED FORNEY FORNEY FORNEY REMARKS: ASTM C39, C174, C192, C470, C617, C42 COMPLIES: X DOES NOT COMPLY: ------------------------------------------------------------------------------ THIS REPORT SHALL NOT BE REPRODUCED, EXCEPT IN FULL WITHOUT '-HE APROVAL OF SITI ------------------------------------------------------------------------------- RESPECTFULLY SUBMITTED SOUTHWES INSPECTIjON aND TESTING SAMPLES CAST BY OTHERS: RENAN R. CRU25' LAB. MANAGER ASTM C39 BREAKS A= cone B= cone and split C= cone D=shear E=columnar SOUTHWEST INSPECTION AND TESTING INC. 441 COMMERCIAL WAY LA HABRA, CA 90631-6168 562-941-2990 714-526-8441 Fax -562-946-0026 FIELD DATA ON TEST SPECIMENS --- ASTM C31, C138, C143, C172, C173, C231, -21064'--- CONCRETE: X GROUT: MORTAR: SHOTCRETE: CORES: GUNITE: ADDRESS: 57-600 ROSEWOOD CT..LA QUINTA JOB #: 60280 DATE: 19/22/2007 JOB NAME: PALO VERDE/ TR#32279/PH#2 PERMIT #: 07-2279 ISSUED BY: LA QUINTA` ARCHITECT: BASSENIAN & LAGONI ENGINEER: R.G.F. CONTRACTOR: STANDARD PACIFIC SUB CONTRACTOR: DIAZ CONC. -------------------------------------------------------------------------------- LOCATION IN STRUCTURE: FOOTINGS/ LOT#27 CONCRETE SUPPLIER: SUPERIOR PLANT: COACHELLA MIX #: D83625P TYPE OF CEMENT : V ADMIXTURE: TIC{ET #: 22006 SLUMP : 4 1/2" WATER ADDED: 0 GAL. AIR TEMP:. 68 F CONCRETE TEMP: 70 F MIXING TIME: 25 MIN. TIME CAST: 7:15 --------------------------------------------------------------------------------- DATE CAST: 9/21/2007 RECEIVED AT LAB: 9/22/2007 -------------------------------------------------------------------------------- SPECIMENS MADE.BY: BILL LA GRANDE SPECIFIED PSI: 4..000 FIELD IDENTIFICATIONI A I B i C I D I E LAB IDENTIFICATION 709957 709957 709957 70.3957 AGE DAYS 7 28 28 H. 0 L D DATE TEST 9/28/20.07 10/19/2007: 10/19/2007: SIZE -IN. 4 X 8 4 X 8 4 X 8 AREA-SQ.IN. 12.57 12.57 12.57 CRUSH LOAD -LBS 52280 66910 : 68020 COMP-STR.-PSI. 4160. 5320 5410 H/D CORR FACTOR CORR.STR.-PSI TIME TESTED _ BREAK TYPE C.T.M. USED FORNEY RIEHLE RIEHLE ------------------------------------------------------------------------------ REMARKS: ------------------------------------------------------------------------------ ASTM C39, C174, C1921 C470, C617, C42 COMPLIES: X DOES NOT COMPLY:. ------------------------------------------------------------------------------ THIS REPORT SHALL NOT BE REPRODUCED, EXCEPT IN FULL WITHOUT "HE APROVAL OF SITI ---------------------------------------------------------------------------- RESPECTFULLY SUBMITTED SOUTHWEST INSPECTION AND TESTING. SAMPLES CAST BY OTHERS: RENAN R.CR LAB. MAN v ASTM C39 BREAKS A= cone B= cone and split C= cone D=shear E=columnar. SOUTHWEST INSPECTION AND TESTING INC. 441 COMMERCIAL -WAY LA HABRA, CA 9063176168 562-941-2990 714-526-8441 Fax -562-946-0026 -------------------------------------------------------------------------------- FIELD DATA ON TEST SPECIMENS --- ASTM C31, C138, C143, C172, C173, C231, _-1064 --- CONCRETE: X' GROUT: MORTAR: SHOTCRETE: CORES: GUNITE: ADDRESS: 57-570 ROSEWOOD CT. LA QUINTA JOB #: 60280 DATE: 19/22/2007 JOB NAME: PALO VERDE/ TR#32279/PH#2' PERMIT #: 07-2280 ISSUED BY: LA QUINTA ARCHITECT: BASSENIAN & LAGONI ENGINEER: R.G.F. CONTRACTOR: STANDARD PACIFIC SUB CONTRACTOR: DIAZ COWC. -------------------------------------------------------------------------------- LOCATION IN STRUCTURE: FOOTINGS/ LOT#28 -------------------------------------------------------------------------------- CONCRETE SUPPLIER: SUPERIOR PLANT: COACHELLA MIX #: D83625P TYPE OF CEMENT : V ADMIXTURE: TICKET #: 22010 SLUMP : 4 1/2" WATER ADDED: 0 GAL. AIR TEMP: 72 F CONCRETE TEMP: 70 F MIXING TIME: 30 MIN. TIME CAST: 7:45 -------------------------------------------------------------------------------- DATE CAST: 9/21/2007 RECEIVED AT LAB: 9/22/2007 ------------------------------------------------------------------------------- SPECIMENS MADE BY: BILL LA GRANDE SPECIFIED PSI: 4000 ------------------------------------------------------------------------------- FIELD IDENTIFICATIONI A I B I C I D I E ------------------------------------------------------------------------------- LAB IDENTIFICATION 709958 709958 709958 709958 ------------------------------------------------------------------------------ AGE DAYS 7 28 : 2 8 : H O L D DATE TEST 9/28/2007 10/19/2007: 10/19/2007:. SIZE: -IN. 4 X 8 4 X 8 4 X 8 AREA-SQ.IN. 12.57 12.57 12.57 CRUSH LOAD -LBS 51640 68820 68190 COMP-STR.-PSI. 4110 5470 5425 H/D CORR FACTOR CORR.STR.-PSI TIME TESTED BREAK TYPE C.T.M. USED FORNEY RIEHLE RIEHLE REMARKS: ASTM C39., C174, C192, C470, C617, C42 COMPLIES:X DOES NOT COMPLY: ------------------------------------------------------------ ----------------- THIS REPORT SHALL NOT BE REPRODUCED, EXCEPT IN FULL WITHOUT THE APROVAL OF-SITI RESPECTFULLY SUBMITTED SOUTHWEST INSPECTION rND TESTING SAMPLES CAST BY OTHERS: RENAN R. LAB. ASTM C39 BREAKS A= cone' B= cone and split C= cone D=sr_ear E=columnar SOUTHWEST INSPECTION AND TESTING INC. 441 COMMERCIAL WAY LA HABRA, CA 90631-6168 562-941-2990 714-526-8441 Fax -562-946-0026 FIELD DATA ON TEST SPECIMENS --- ASTM C31, 0138, C143, C172, C173, C231, 01064 --- CONCRETE: X GROUT: MORTAR: SHOTCRETE: CORES: GUNITE: ADDRESS: 57-540 ROSEWOOD CT. LA QUINTA JOB #: 60280 DATE: 19/22/2007 JOB NAME: PALO VERDE/ TR#32279/PH#2 PERMIT #: 07-2281 ISSUED BY: LA QUINTA ARCHITECT: BASSENIAN & LAGONI ENGINEER: R.G.F. CONTRACTOR: STANDARD PACIFIC SUB CONTRACTOR: DIAZ CONC. -------------------------------------------------------------------------------- LOCATION IN STRUCTURE:'FOOTINGS/ LOT#29 -------------------------------------------------------------------------------- CONCRETE SUPPLIER: SUPERIOR = PLANT: COACHELLA MIX #: D83625P TYPE OF CEMENT : V ADMIXTURE: TICKET #: 22034 SLUMP : 4 WATER ADDED: 0 GAL. AIR TEMP: 68 F CONCRETE TEMP: 72 F MIXING TIME: 55. MIN. TIME CAST: 7:10 DATE CAST: 9/24/2007 RECEIVED AT LAB: 9/25/2007 -------------------------------------------------------------------------- SPECIMENS MADE BY: BILL LA GRANDE SPECIFIED PSI: 4000 ---------------------------------------.----------------------------------- FIELD IDENTIFICATIONI A I B I C I D I E --------------------- ------------------------------------------------------ LAB IDENTIFICATION 710015 710015 7100.15 710015 AGE DAYS 7 28- 28 H 0 L D DATE TEST, 10/1/2007 10/22/2007: 10/22/2007: SIZE -IN. 4 X 8 4 X 8 4 X 8 AREA-SQ.IN: 12.57 12.57 12:57 CRUSH LOAD -LBS 5080.0 62960 68200 COMP-STR.-PSI.. 4040 5010 5425 H/D CORR FACTOR CORR.STR.-PSI TIME TESTED BREAK TYPE C.T.M. USED FORNEY FORNEY FORNEY ------------------------- REMARKS: ----------------------------------------------------------------- --------- ASTM C39, C174, C192, C470, C617, C42 COMPLIES: X DOES NOT COMPLY: ------------------------------------------------------------------------------ THIS REPORT SHALL NOT BE REPRODUCED, EXCEPT IN FULL WITHOUT -HE APROVAL OF SITI ----------------------------- -------------------------------------------------- RESPECTFULLY SUBMITTED SOUTHWEST INSPECTION AND TESTING SAMPLES CAST -BY OTHERS: R NAN R.CR LAB. MAN P ASTM C39 BREAKS A= cone B= cone and split C= cone D=shear E=columnar SOUTHWEST.INSPECTION AND TESTING INC. 441 COMMERCIAL.WAY LA HABRA, CA 90631-6168 562-941-2990 714-526-8441 Fax -562-946-0026 -------------------------------------------------------------------------------- FIELD.DATA ON TEST SPECIMENS . -- ASTM C31, C138, C143, C172, C173, C231, -1064 --- CONCRETE: X GROUT: ' MORTAR: SHOTCRETE: CORES: GUNITE: ADDRESS: 57-510 ROSEWOOD CT. LA QUINTA JOB #: 60280 DATE: 19/22/2007 JOB NAME: PALO VERDE/ TR#32279/PH#2 PERMIT #: 07-2282 ISSUED BY: LA QUINTA ARCHITECT: BASSENIAN & LAGONI ENGINEER: R.G.F. CONTRACTOR: STANDARD PACIFIC SUB CONTRACTOR: DIAZ CONC. -------------------------------------------------------------------------------- LOCATION IN STRUCTURE: FOOTINGS/ LOT#30 CONCRETE SUPPLIER: SUPERIOR PLANT: INDIO MIX #: D83625P TYPE OF CEMENT : V ADMIXTURE: TICKET #: 43385 SLUMP : 4" WATER ADDED: 0 GAL. AIR TEMP: 74 F CONCRETE TEMP: 72 F MIXING TIME: 50 MIN. TIME CAST: 8:25 -------------------------------------------------------------------------------- DATE CAST: 9/24/2007 RECEIVED AT LAB: 9/25/2007 --------------------------------------------------------------------------------- SPECIMENS MADE BY: BILL LA GRANDE SPECIFIED PSI: 4000 -------------------------------------------------------------------------------- FIELD IDENTIFICATIONI A I B I C I D I. E ------------------------------------------------------------------------------- LAB IDENTIFICATION 710016 710016 710016 :710016 ----------------------------------7-------------------------------------------- AGE DAYS 7. 28 28 H: O L D DATE TEST 10/1/2007 10/22/2007: 10/22/2007: SIZE -IN. 4 X 8 4 X 8 4 X 8 AREA-SQ.IN. 12.5.7 12.57 12.5,7 CRUSH LOAD -LBS 48200 66790 66570 COMP-STR.-PSI. 3835 5310 5295 H/D CORR FACTOR CORR.STR:-PSI TIME TESTED - --- BREAK TYPE C.T.M. USED FORNEY FORNEY FORNEY, " ASTM C39, C174, C192, C470, C617, C42 COMPLIES: X DOES NOT COMPLY: ------------------------------------------------------------------------------ THIS REPORT SHALL NOT BE REPRODUCED, EXCEPT IN FULL WITHOUT THE APROVAL OF SITI RESPECTFULLY SUBMITTED SOUTHWEST INSPECTION AND TESTING SAMPLES CAST BY OTHERS: RENAN R.0 LAB. ASTM C39 BREAKS A= cone B= cone.and split C= cone D=sr.ear E=columnar