07-1191 (SFD)4 P.O. BOX 1504 ^�
78-495CALLE TAMPICO
LA QUINTA, CALIFORNIA 92253 BUILDING & SAFETY DEPARTMENT
BUILDING PERMIT
Application Number: ;` 07-00001191 ` Owner:
Property Address: 57630 ROSEWOOD --CT STANDARD PACIFIC
APN: 762-240-011-26 -32279 - 15326 ALTON PKWY
Application description: DWELLING - SINGLE FAMILY DETACHED IRVINE, CA 92618
Property Zoning: LOW DENSITY RESIDENTIAL (949)789-1600
Application valuation: 208902
Applicant:
rchitect or Engineer:
[7-B 24a4Z:W �el�s
LICENSED CONTRACTOR'S DECLARATION
I hereby affirm under penalty of perjury that I kens nder provisions of Chapter 9 (commencing with
Section 7000) of Division 3 of the Busine and Professiona Code, and my License is in full force and effect.. -
License Class: B 665
Date: ntractor:
OWNER -BUILDER DECLA
I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the
following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to
construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the
permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State
License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or
that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by
any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).:
I _ ) I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and
the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The
Contractors' State License Law does not apply to an owner of property who builds or improves thereon,
and who does the work himself or herself through his or her own employees, provided that the
improvements are not intended or offered for sale. If, however, the building or improvement is sold within
one year of completion, the owner -builder will have the burden of proving that he or she did not build or
improve for the purpose of sale.)..
(_ 1 I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec.
7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of
-- - property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed
pursuant to the Contractors' State License Law.l.
(_ I I am exempt under Sec. , B.&P.C. for this reason
Date: Owner:
CONSTRUCTION LENDING AGENCY
I -hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the
work for which this permit is issued (Sec. 3097, Civ. C.).
Lender's Name:
Lender's Address:
LQPERA11T
VOICE (760) 777-7012
FAX (760) 777-7011
INSPECTIONS (760) 777-7153
COACHELLA VLY
Contractor: D d
STANDARD PACIFI RP
15326 ALTON PK
IRVINE, CA 926 8n
(949) 789-1600 - AY ll / 1Uo�
Lic. No.: 641 65 C/�.
/A !_11A OerA _
Date: 4/19/07
WORKER'S COMPENSATION DECLARATION
I hereby affirm under penalty of perjury one of the following declarations:
_ 1 have and will maintain a certificate of consent to self -insure for workers' compensation, as provided
for by Section 3700 of the Labor Code, for the performance of the work for which this permit is
a -Ai issued.
I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor
Code, for the performance of the work for which this permit is issued. 'My workers' compensation
insurance carrier and policy number are:
Carrier SEA BRIGHT INS Policy Number BB1070237
I certify that, in the performance of the work for which this permit is issued, I shall not employ.any
person in any manner so as ome subject to the workers' compensation laws of California,
and agree that, if I shou dome bject to the workers' compensation provisions of Section
3700 of the Labor Co e, I shall forth it n ly ith those provisions.
e:pplicanv
WARN G: FAILURE TO SECURE WORKERS' COMPENSATION C ERAGE IS LAWFUL, AND SHALL
SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND
DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION; DAMAGES AS PROVIDED FOR IN
SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES.
APPLICANT ACKNOWLEDGEMENT
IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the
conditions and restrictions set forth on this application.
1. Each person upon whose behalf this application is made, each person at whose request and for -
whose benefit work is performed under or pursuant to any permit issued as a result of this application,
the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City
of La.Quinta, its officers, agents and employees for any act or omission related to the work being
performed under or following issuance of this permit.
2. Any permit issued as a result ofthis application becomes null and void if work is not commenced
within 180 days from date of issuance of such permit, or cessationof work for 180 days will subject
permit to cancellation. -
I certify that I have read this application and state that th ove' formation is correct. I agree to comply with all
city and county ordinances and state laws relating to byt ding const uction, nd hereby authorize representatives
of th!scyuiyy t enter upon the above-mentioned pr de r o es.
Date: � nature (Applicant or Agen '
Application Number .
. . . . 07-00001191
Permit . . .
BUILDING PERMIT
Additional desc .
Permit Fee
1021.00
Plan Check Fee
165.91
Issue Date
Valuation
208902
Expiration Date
10/16/07
Qty. Unit Charge
Per
Extension
BASE
FEE
639.50
109.00 3.5000
THOU BLDG
100,001-500,000
381.50
Permit . . .
MECHANICAL
Additional desc..
Permit Fee . . . .
101.00
Plan Check Fee
6.31
Issue Date . . . .
Valuation
0
Expiration Date..
10/16/07
Qty Unit Charge
Per
Extension
BASE
FEE
15.00
2.00 9.0000
EA MECH
FURNACE <=100K
18.00
.2.00 9.0000
EA MECH
B/C <=3HP/100K BTU
18.00
6.00 6.5000
EA MECH
VENT FAN
39.00
1.00 •11.0000
---------------------------------
EA MECH
------------------------------------------
DOMESTIC INCINERATOR
11.00
Permit ELEC-NEW RESIDENTIAL
Additional desc .
Permit Fee . . . .
1.46.32
Plan Check Fee
9.15•
Issue Date
Valuation . . . .
0
Expiration Date
10/16./07
Qty Unit Charge
Per
Extension
BASE
FEE
15.00
3380.00 .0350
ELEC
NEW RES - 1 OR 2 FAMILY.
118.30
651.0.0. .0200
--------------------------
ELEC
------------
GARAGE OR NON-RESIDENTIAL
-----------------------------
13.02
---------
- Permit . . . PLUMBING
Additional desc .
Permit Fee . . . .
191.25
Plan Check Fee
11.95
Issue Date . . . .
Valuation
0
Expiration Date
10/16,/07
Qty Unit Charge
Per.
Extension
BASE
FEE
15.00
20.00 6.0000
EA PLB FIXTURE
120.00
1.00 15.0000
EA PLB BUILDING SEWER
15.00
LQPERAIIT
LQPERMIT
Application Number .
. . . . 07-00001191
Permit . .. PLUMBING
Qty Unit.Charge
Per
Extension
1.00 7.5000
EA PLB WATER HEATER/VENT
7.50
.1.00 3.0000
EA PLB-WATER INST/ALT/REP
3.00
1.00 9.0000
EA PLB LAWN SPRINKLER SYSTEM
9.00
9.00 .7500
EA PLB GAS PIPE >=5
6.75
1.00 15.0000
-------------------------------------------------
EA PLB GAS METER
---------------------------
15.00
Permit'. . . GRADING PERMIT
Additional desc .
Permit Fee . . . .
15.00 Plan Check Fee
.00
Issue Date . . . .
Valuation . . .
. 0
.Expiration Date
10/16/07
Qty Unit Charge
Per
Extension
BASE FEE.
15.00
- ---------------------------------------------------------
Special Notes and Comments
SFD -.LOT 26, PLAN 1SR, 3380 SF. PERMIT
DOES NOT INCLUDE POOL,
SPA, BLOCK WALLS
OR DRIVEWAY APPROACH.
75% REDUCTION TO
PLAN CHECK FEES DUE TO MULTIPLE
ISSUANCE OF SAME PLAN
TYPE 2001.CBC,
CMC,
CPC, 2004 CEC, 2005 ENERGY CODES
Other Fees . . .
. . . ART IN PUBLIC PLACES -RES
22.25 '
DIF COMMUNITY CENTERS -RES
74.00
DIF CIVIC CENTER _ RES
995.00
ENERGY REVIEW FEE
16.60
DIF FIRE PROTECTION -RES
140.00
GRADING PLAN CHECK FEE
.00
DIF LIBRARIES - RES
355.00
DIF PARK MAINT FAC - RES
22.00
DIF PARKS/REC - RES
892.00
REPLACEMENT INSP CARD
15.00'
STRONG MOTION (SMI) - RES
20.89
DIF STREET MAINT FAC -RES
67.00
DIF TRANSPORTATION - RES
1930.00
Fee summary Charged
Paid Credited
1?1de
Permit Fee.Total
1474.57 .00 .00
1474.57
Plan Check Total
193.32 .00 .00
193.32
Other Fee Total
4549.74 .00 .00
4549.74
Grand Total
6217.63 .00 .00
6217.63
ENGINEERING, INC.
structural consult,ing awd design
July 23, 2007
Standard Pacific of Coachella Valley
PMB #303
1717 E Vista Chino Rd, Ste A7
Palm Springs, CA 92262 .
ATTN: Troy Hefner
Palo Verde
StructuralObservation - _
Lot 26-1SR 57 630 RosewoodCortl
Dear Mr. Hefner,
In accordance•with your request our office performed a site observation of the Palo Verde project in order
to observe the framing to date of the -above mentioned lot and have found it in general conformance with
the plans. The site visit consisted of a walk through observation of the construction that was visible. No
dismantling of construction or testing was .performed to verify construction that was not readily visible.
The observation does not relieve the contractor and builder from making sure that the construction
conforms to the city approved construction documents. If you should have any questior.s, please contact
this office.
Sincerely,
OFESW
Richar reitas, P.E. Q� ani
President
'i 00 2 -
li w ¢ No. >D72 �m
Exp.
471 W. Lambert Road, Suite 105
Brea, California 92821
1 phone (714)256.2722 fax (714)256.9182
It
.
SOUTHWEST INSPECTION AND TESTING INC.
441 COMMERCIAL WAY
LA HABRA, CA 90631-6168
562-941-2990 714-526-8441 Fax -562-946-0026
--------------------------------------------------------------------------------
--------------------------------------------------------------------------------
FIELD DATA ON TEST SPECIMENS
-- ASTM C31, C138, C143, C172, C173, C231, C1064 ---
CONCRETE: X GROUT: MORTAR: SHOTCRETE: CORES: GUNITE:
ADDRESS: 57-630 ROSEWOOD CT. LA QUINTA JOB #: 60280 DATE: 6/30/2007
JOB NAME: PALO VERDE/TR#32279/PH#1 PERMIT #: 071191 ISSUED BY: LA QUINTA
ARCHITECT: BASSENIAN & LAGONI ENGINEER: RGF ENGINEERING
CONTRACTOR: STANDARD PACIFICI HOMES SUB CONTRACTOR: DIAZ CONST.
--------------------------------------------------------------------------------
LOCATION IN STRUCTURE: LOT#26/ FOOTINGS
--------------------------------------------------------------------------------
CONCRETE SUPPLIER: SUPERIOR PLANT: 74 MIX #: D83625P
TYPE OF. CEMENT : V ADMIXTURE: TICKET #: 19270
SLUMP : 4 1/2" WATER ADDED: 0 GAL. AIR TEMP: 80 F
CONCRETE TEMP: 86 F MIXING TIME: 35 MIN. TIME CAST: 8:58
--------------------------------------------------------------------------------
DATE CAST: 5/23/2007 RECEIVED AT LAB: 5/24/2007
-------------------------------------------------------------------------------
SPECIMENS MADE BY: PHILIP A. PETTEREZ SPECIFIED PSI: 4000
-------------------------------------------------------------------------------
FIELD IDENTIFICATIONI A I B I C i D I E
-------------------------------------------------------------------------------
LAB IDENTIFICATION : 705818 : 705818 : 705818 : 705818
-------------------------------------------------------------------------------
AGE DAYS 7 28 28 H O L D
DATE TEST 5/30/2007 6/20/2007 6/20/2007
SIZE -IN. 4 X 8 6.000X12 6.000X12
AREA-SQ.IN. 12.56 28.27 28.27
CRUSH LOAD -LBS 47100 128970 134520
COMP-STR.-PSI. 3750 4560 4760
I H/D
CORR FACTOR
CORR:STR.-PSI
TIME TESTED
BREAK TYPE
C.T.M. USED FORNEY FORNEY FORNEY
REMARKS:
ASTM C39, C174, C192, C470, C617, C42
COMPLIES: X DOES NOT COMPLY:
------------------------------------------------------------------------------
THIS REPORT SHALL NOT BE REPRODUCED, EXCEPT IN FULL WITHOUT THE APROVAL OF SITI
---------------------------------------------------------------------------
RESPECTFULLY SU MITTED
SOUT ST INS CTION AND TESTING
SAMPLES CAST BY OTHERS:
RENAN R d9WGZ
LAB. MANAGER
ASTM C39 BREAKS A= cone B= cone and split C= cone D=shear E=columnar
SOUTHWEST INSPECTION AND TESTING INC.
441 COMMERCIAL WAY
LA HABRA, CA 90631-6168
562-941-2990 714-526-8441 Fax -562-946-0026
----------------
FIELD DATA ON TEST SPECIMENS
---k ASTM C31,, C138, C143, C172, C173, C231, C1064 -
CONCRETE: X GROUT: MORTAR: SHOTCRETE: CORES: GUNITE:
ADDRESS: `5T7 6 7@RO:S-EWOOD--C—T. LA QUINTA JOB #: 60280 DATE: 10/15/2007
JOB NAME PALO VERDE/ TR#32279/PH#1 PERMIT #: 07-2165 ISSUED BY: LA QUINTA
ARCHITECT: BASSENIAN & LAGONI ENGINEER: R.G.F.
CONTRACTOR: STANDARD PACIFIC SUB CONTRACTOR: MASONRY GRP.
--------------------------------------------------------------------------------
LOCATION IN STRUCTURE: FOOTINGS/ BLACKWALL/ LOT#26 BETWEEN 25 & 26
--------------------------------------------------------------------------------
CONCRETE SUPPLIER: ASSOCIATED PLANT: INDIO MIX #: AA1601
TYPE .OF CEMENT : II ADMIXTURE: TICKET #: 6320210
SLUMP : 5" WATER ADDED: 0 GAL. AIR TEMP: 72 F
CONCRETE TEMP: 70 F MIXING TIME: 40 MIN. TIME CAST: 8:15
--------------------------------------------------------------------------------
DATE CAST: 9/17/2007 RECEIVED AT LAB: 9/18/2007
-------------------------------------------------------------------------------
SPECIMENS MADE BY: BILL LA GRANDE SPECIFIED PSI: 2500
--------------------------------------
FIELD IDENTTFICATIONI A I B I C I D I E
----------------------------------------------------=--------------------------
LAB IDENTIFICATION 709765 709765 709765 709765
-------------------------------------------------------------------------------
AGE DAYS 7 28 28 H O L D
DATE TEST 9/24/2007 10/15/2007: 10/15/2007:
SIZE -IN. : 4 X 8 4 X 8 : 4 X 8
AREA-SQ.IN. 12.57 12.57 12.57
CRUSH LOAD -LBS 24270 36420 34660
COMP-STR.--PSI. 1930 2900 2760
I H/D
CORR FACTOR
CORR.STR.-PSI
TIME TESTED
BREAK TYPE -
C.T.M. USED FORNEY FORNEY FORNEY
REMARKS:
ASTM C39, C174, C192, C470, C617, C42
COMPLIES: X DOES NOT COMPLY:
------------------------------
THIS REPORT SHALL NOT BE REPRODUCED, EXCEPT IN FULL WITHOUT THE APROVAL OF SITI
--------------------------------------------------------------------------
RESPECTFULLY SUBMITTED
SAMPLES CAST BY OTHERS: SOUTHWEST INSPECTION AND TESTING
ENAN R.CRU
LAB. MANA
ASTM C39 BREAKS A= cone B= cone"'and split C= cone D=shear E=columnar
_ f
2007/07/30 07:13:50 1-951-739-9509 1-951-739-9501 Powered by Lightn•engFAX Page:2/2
1-951-739-9501 MEPS Ready
1610 Maple St.
Corona, CA 92880
AIR CONK)ITIO W
INQ S.C.L. #585972
Job# 6150 Lot# 26
Date 7/30/2007
Job Name Palo Verde Phase 1 Address"57 630°ROS_EWOOD Lot13D 22074
Builder Standard Pacific of the City LA QUINTA- '
Your Westpac Heating and Air Conditioning system is ready for MEPS inspection.
If you have any questions or concerns regarding this lot, please contact us at (951) 739-9501.
INSTALLATION CERTIFICATE (page 3 of 13) CF-6R
�a-
Site Address 7
Permit Number
DUCT LEAKAGE AND DESIGN DIAGNOS'T'ICS
DUCT LEAKAGE REDUCITON
P on Test Results (CFM ® 25 PA)
Fan Flow Test Leakage (CFM)
If Fan Flow is Calculated as 400 c6n/ton x number of tons, or as 21.7 x Heating Capacity ���-
in Thousands. ofBtdhr, enter calculated value here —t w 0
If fan flow is measured, enter measured value here
Leakage Fraction = Test Lealcage/(Meesured or Calculated Fan Flow) -
Pass if leakage fraction:5 0.06
ftor AEROSOL TYPE SEALANTS ONLY - The following db P Fail
� R�s1k testing was completed':
Duct Fan Pressurization at rough-in measured leakage (CFM)
CHECK AFTER FEWSHING WALL:
0 Yes 0 No 0 Pressure pan test or House pressurization test
0 Yes 0 No • Q Visual Inspection of Duct Corm
ections 0
11
Pass Fail
THERMOSTATIC EXPANSION VALVE
Yes 0 No Thermostatic Expansion Valve is installed and Access is
provided for inspection AZI
Yes is a pass Pas>; Fail
DUCT DESIGN
I 0 Yes 0 No ACCA Manual D Design Oucuhmtio» s have been
completed, Duct Design is on the plans and duct histallation
matches Vians.
2. 0 Yes 0 No TXV is installed or Fan flow has been verified. If no TXV,
verified favi now matches design from CF-IR.
Measured Fan Flow =
Yes for both I and 2 is a Pass Pass Fail
tML
the undelsigned, verily that the above diagnostic test results and the work I performed asaociate&with The
dace with the're;gnic�ats tests) is in
compliance credit. (The builder shall provide the HERS provider s copy of the CF-611
for ed by the ildei employ or sub-cxmtractors certifying that diagnostic testing and installation meet the requirements
ell
Z2" ,
lsjo�TC
Testsgesture, Date-
Performed Installing.Subeontractor (Co. Name) OR
COPY TO: Building Deptounent General Contractor (Co. Name)
HERS Provider (if applicable)
Building Owner at Occupancy
Compliance Forms August 2001
A-25
4 - '. A
i
INSTALLATION CERTiFIV A TT
Permit Number
DUCT LEAKAGE AND DESIGN -DIAGNOSTICS
LEAKAGE REDUCITON
M Test Results (CFM ®25 PA}
Fan Flow Test Leakage (CFM) U-7
If Fan Flow is Calculated as 400 cSnRon x number of tons, or as 21.7 x Heating Capacity
'in Thousands.ofBtulhr, enter calculated vahre here 600
If fan flow is measured, enter meaSuted value here
Leakage Fraction =Test Leakage/(Measured or Calculated Fan Flow) a
Pass if leakage fraction S 0.06
0 ftor AEROSOL TYPE SEALANTS ONLY - The following d itgeostle txRiag was completerb
Duct Fan Pressurization at rough -in measured leakage (CFM)
CHECK AFTER FEMSH[MG WALL:
0 Yes 0 No 0 Pressure pan test or House pressurization test
0 Yes 0 No • ® Visual Inspection of Duct Connections
THERMOSTATIC EXPANSION VALVE (TX
CF -6R
-t11 '
P6 Fail
0 0
Pass Fail
Yes O No Thermostatic Expansion Valve is installed and Access is
provided for inspection
Yes is a pass
Yass Fail
DUCT DESIGN
1' 0 Yes 0 No ACCA Manual D Design calwlatlons have been
completed, Duct resign Is on the plans and duct itistellation
matches plans.
2. ® Yes D ,No TXV is installed or Pan flow has been verified. If no TXV,
verified fan flow matches design from CF -IR.
Measured Fan Flow13,
=
Yes for both land 2 is a Pass as
Pass Fail
Vq�OmLancc
the renders � f=4 dud ore above do test results and the worki performed associated with ure tests) is in
with the' compliance credit, [The builder shall provide the HERS
signed by the builder employees or sub -contractors cert Aft that di Pider s copy ofthe CF -6R
for compliance credit agnostic testing and instatla8on meel.the requirements
Tests Sig�Dge
Performed Instal liag.Subeorrhactor (Co. Nene) OR
COPY TO: Building Deparhuem Gerww Contractor (Co. Name)
HERS Provider (if applicable)
Building owner at Occupancy
Compliance Forms ' August 2001
A-25
VT
Ce, tof
ficate of0ccupancy
OF Building Safety- Department
14
This Certificate is issued pursu ant to.the requirements of Section 109 of the California Building
Code, certifying that, at the time of issuanc6, this structure was in compliance with the
provisions of the Building Code and the various ordinances of the City regulating- building
construction andlor use.
BUILDING ADDRESS: 57- 630 ROSEWOOD COURT
Use classification: SFD Building Permit No.: 07-1191
Occupancy Group R-3 of Construction: VN Land. Use Zone: RL
.Type
Owner of Building: STANDARD PACIFIC HOMES Address'. 1717 E.YISTA CHINO RD, STE A7
City, ST, ZIP- PALM SPRINGS, CA.
By: KIRK KIRKLAND
Date: NOVEMBER 8, 2007
Building Official
POST IN A CONSPICUOUS PLACE