Loading...
07-1187 (SFD)P:O. BOX 1504 78-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 4 zfk Qamm BUILDING & SAFETY DEPARTMENT BUILDING PERMIT Application Number: _07.-00001187 1 Owner: VOICE (760) 777-7012 FAX (760) 777-7011 INSPECTIONS (760) 777-7153 Date: 4/19/07 Property Address: 57685 ROSEWOOD CT STANDARD PACIFIC COACHELLA VLY APN: 762-240-011-7 -32279 - 15326 ALTON" PKWY' Application description: DWELLING - SINGLE FAMILY DETACHED IRVINE, CA 92618 Property Zoning: LOW DENSITY RESIDENTIAL (949) 789-1600 Application valuation: 232894 D 6 Applicant: rchaect or Engineer: Contractor: STANDARD PACIFIC CORP ry q 15326 ALTON PKWY MAY 0 l LOOT IRVINE, CA 92618. (949) 789-1600 C17 -Y OF LA QUINTA Lic. No.: 641665 ---------------------------------------.---------------------------------------------------------- LICENSED CONTRACTOR'S DECLARATION WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with 1 hereby affirm under penalty of perjury one of the following declarations: • Section 7000) of Division 3 of the Busin s an irofessio_qajs, Code, and my License is in full force and effect. I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided Licens Class: B i nse o.: 41665 _ for by Section 3700 of the Labor Code, for the performance of the work for which this permit is b Date: S D � ontractor: issued. I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation - 0 ECLARATION insurance carrier and policy number are: I hereby affirm under penalty of perjury that 1 am exempt from the Contractor's State License Law for the Carrier SEA BRIGHT INS Policy Number BB1070237 following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to _' I certify that, in the performance of the work for which this permit is issued, I shall not employ any construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the person in any manner so as to become subject to the workers' compensation laws of California, permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State and agree tha ' lshou - ome subject the workers' compensation provisions of Section License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or 700 ofLabor C e, I.sha ar fiOvi o ply those provisions. that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by - any applicant for a permit subjects the applicant to a. civil penalty of not more than five hundred dollars ($5001.:e: —6A cant: _ (_ 1 I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and //off the structure is not intended or offered for sale ISec. 7044, Business and Professions Code: The WARN( G. FAILURE TO SECURE WORKERS' C E T NCO RAGE IS UNLAWFUL, AND SHALL Contractors' State License Law does not apply to an owner of property who builds or improves thereon, SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CI S UP TO ONE HUNDRED THOUSAND and who does the work himself or herself through his or her own employees, provided that the DOLLARS ($700,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN . improvements are not intended or offered for sale. If, however, the building or improvement is sold within SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. ' ' one year of completion, the owner -builder will have the burden of proving that he or she did not build or • improve for the purpose of sale.). - APPLICANT ACKNOWLEDGEMENT ' • 1 _ 1 1, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of conditions and restrictions set forth on this application. property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed 1. Each person upon whose behalf this application is made, each person at whose request and for ' ' pursuant to the Contractors' State License Law.). whose benefit work is performed under or pursuant to any permit issued as a result of this application, (_ 1 I am exempt under Sec. , BAP.C. for this reason the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City Date: Owner: ' CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Name: Lender's Address: LQPERMIT of La.Quinta, its officers, agents and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that theabo information .is correct. I agree to comply with all city and c hty ordinances and state laws relating to buil ' g constr tion, an ereb authorize representatives of thi o=n¢y t enter upon the above-mentioned y or ins ate: 0 Signature (Applicant or Agent): LQPERM[T _ Application Number . . . . . .07-00001187 Permit BUILDING PERMIT Additional desc . Permit Fee . . . . 1105.00 Plan Check Fee. 179.56 Issue Date Valuation 232984 Expiration Date 10/16/07 Qty Unit Charge _ Per Extension BASE FEE 639.50 133.00 3.5000 THOU BLDG 100,001-500,000 465.50 1. Permit . . ". MECHANICAL Additional desc . Permit Fee 96.50 Plan Check Fee 6.03 Issue Date . . . .. Valuation 0 Expiration'Date 10/16/07 Qty Unit Charge Per Extension BASE FEE 15.00 "2.00 9.0000 EA MECH FURNACE <=100K '18.00 2.00 9.0000 EA MECH B/C <=3HP/100K BTU 18..00 6.00 6.5000 EA MECH VENT FAN 39.00 1.00 6.5000 EA MECH EXHAUST HOOD 6.50 Permit . . . . ELEC-NEW RESIDENTIAL Additional desc . Permit Fee . . . . 162.57 Plan Check Fee 10.16 Issue Date . . Valuation . .". . 0 Expiration Date 10/16/07 Qty Unit Charge Per ..Extension BASE FEE 15.00 38.55.00 .0350 ELEC NEW RES - 1 OR 2 FAMILY 134.93 632.00 .0200 ---------------------------------------------------------------------------- ELEC GARAGE OR NON-RESIDENTIAL 12.64 Permit . . . PLUMBING Additional desc . Permit Fee . . . . 202.50 Check Fee 12.66 Issue Date . . . _Plan Valuation 0 Expiration Date 10/16/07 Qty Unit. Charge Per Extension BASE FEE 15.00 22.00 6.0000 EA PLB FIXTURE 132.00 1.00 15.0000 EA PLB BUILDING SEWER 15.00. LQPERM[T _ LQPERMIT .. Application Number 07-00001187 Permit . . . . . PLUMBING Qty Unit Charge Per Extension 1.00 7.5000. EA PLB WATER HEATER/VENT 7.50 1.00 3.0000 EA PLB WATER INST/ALT/REP 3.00 1.00 9.0000 EA PLB LAWN SPRINKLER SYSTEM 9.00 8.00 .7500 EA PLB GAS PIPE >=5 6.00 1.00 15.0000 EA PLB GAS METER ---------------------------------------------------------------------------- 15.'00. Permit . . . GRADING PERMIT Additional desc . Permit Fee . . . . 15.00 Plan Check Fee .00 Issue Date Valuation .. 0 Expiration Date 10/16/07 Qty Unit Charge Per Extension BASE FEE 15.00 -------------------------------------------- --- - Special Notes and Comments SFD --LOT 7, PLAN 3SCR, 3855 SF. PERMIT DOES NOT INCLUDE POOL, SPA, BLOCK WALLS OR DRIVEWAY APPROACH. 75% REDUCTION TO F PLAN CHECK FEES DUE TO MULTIPLE ISSUANCE OF SAME OF PLAN TYPE. 2001 CBC, CMC., CPC, 2004 CEC, 2005 ENERGY CODES ----------------------------------------------------------------------------- Other Fees . . . . . . . . . ART IN PUBLIC PLACES -RES 82.23 DIF COMMUNITY CENTERS -RES 74.00 DIF CIVIC CENTER.- RES 995..00 . ENERGY REVIEW'FEE 17.96 DIF FIRE PROTECTION -RES 140.0`0 GRADING PLAN CHECK FEE .00 DIF LIBRARIES,.- RES 355.00 DIF PARK.MAINT FAC - RES 22.00 DIF PARKS/REC - RES 892.00 . REPLACEMENT INSP'CARD" 15.00 STRONG MOTION (SMI) - RES .23.28 DIF STREET MAINT FAC -RES 67.00 DIF TRANSPORTATION - RES 1930.00 Fee summary Charged Paid Credited Due Permit Fee Total 1581.57 .00 .00 1581.57 Plan Check Total• 208.41 .00 .00 208.41 Other. Fee Total 4613.47 .00 .06 4613.47 Grand -Total 6403.45 .00 .00 640.3.45 LQPERMIT .. ENGINEERING, INC. structural consulting and design July 17, 2007 Standard Pacific of Coachella Valley PMB #,303 1717 E Vista Chino Rd, Ste A7 Palm Springs; CA 92262 ATTN: Troy. Hefner RE: Palo. Verde Structural. Observation_._ ' LLot 7-3SCR; 57-685 kosewood Courtl Dear Mr: Hefner, In accordance with your request our office performed a site observation of the Palo Verde project in order to observe the framing to date of the above mentioned lots and have found them in .general conformance with.the plans. The site visit consisted of a walk through observation of the construction that was visible.. No dismantling of construction or testing was performed to verify construction that was-not readily visible. The observation does not relieve the contractor and builder from making sure that the construction conforms to the city approved construction documents. If you should have any questions, please contact this office. Sincerely,. Richard G`Freitas, P.E. President eoV ESs/6' F 0 �No. rill W rrt Exp. 0 - -0 471 W. Lambert Road, Suite 105 Brea, California 92821 phone (714)256.2722 fax (714)256.9182 SOUTHWEST INSPECTION AND TESTING INC. 441 COMMERCIAL WAY LA HABRA, CA .90631-6168 562-941-2990 714-526-8441 Fax -562-946-0026 -------------------------------------=------------------------------------------ -------------------------------------------------------------------------------- FIELD DATA ON TEST SPECIMENS --- ASTM C31, C138, C143, C172, C173, C231, C1064 --- CONCRETE: X GROUT: MORTAR: SHOTCRETE: CORES: GUNITE: �ADDRES=S-i-5 7 F6'8�5'"RROS.EWOOD–CT . LA QUI NTA JOB #: 60280 DATE : 6/29/2007 JOB NAME: PALO VERDE/TR#32279/PH#1 PERMIT #: 071187 ISSUED BY: LA QUINTA ARCHITECT: BASSENIAN & LAGONI ENGINEER: RGF ENGINEERING CONTRACTOR: STANDARD PACIFICI HOMES SUB CONTRACTOR: DIAZ CONST. -------------------------------------------------------------------------------- LOCATION IN STRUCTURE: LOT#7/ SLAB -------------------------------------------------------------------------=------ CONCRETE SUPPLIER: SUPERIOR PLANT: 74 MIX #: D83625P TYPE OF CEMENT : V ADMIXTURE: TICKET #: 19172 SLUMP : 5 1/4" WATER ADDED: 10 GAL. AIR TEMP: 90 F CONCRETE TEMP: 85 F MIXING TIME: 34 MIN. TIME CAST: 10:20 -------------------------------------------------------------------------------- DATE CAST: 5/21/2007 RECEIVED AT LAB: 5/22/2007 ------------------------------------------------------------------------------- SPECIMENS MADE BY: PHILIP A. PETTEREZ SPECIFIED PSI: 4000 ------------------------------------------------------------------------------- FIELD IDENTIFICATIONI A I B I C I D I E ------------------------------------------------------------------------------- ' LAB IDENTIFICATION : 705697 : 705697 705697 : 705697 -------------------------------------------------=----------------------------- AGE DAYS 7 28 28 H 0 L D DATE TEST 5/28/2007 6/18/2007 6/18/2007 SIZE -IN. 4 X 8 6.000X12 6.000X12 AREA-SQ.IN. 12.56 28.27 28.27 CRUSH LOAD -LBS 44120 128830 133910 COMP-STR.-PSI. 3510 4560 4740 I H/D CORR FACTOR CORR.STR.-PSI TIME TESTED BREAK TYPE C.T.M. USED FORNEY FORNEY FORNEY REMARKS: ASTM C39, C174, C192, C470, 0617, C42 COMPLIES: X DOES NOT COMPLY: ------------------------------------------------------------------------------ THIS REPORT SHALL NOT BE REPRODUCED, EXCEPT IN FULL WITHOUT THE APROVAL OF SITI ------------------------------------------------------------------------------- RESPECTFULLY SUBMITTED SOUTH ST INSP CTION AND TESTING SAMPLES CAST BY OTHERS: RENAN R LAB. MANAGER ASTM C39 BREAKS A= cone B= cone and split C= cone D=shear E=columnar 2007/07/18 07:01:.12 1-951--7..39-9509 _1-951-739-9501 Powered -by LightningFAX Page:2/2 1-951-739-9501 MEPS Ready 1610 Maple St., &ieXT��AC Corona, CA 92880 AIR cowirior W S.C.L. #585972 INC, Job# 6150 r tot# 7 Date . 7/18/2007 Job Name Palo Verde Phase 1 . A0 r_ess 5T685`R"QS.E_W-O_QD� LotiD 22070 Builder Standard Pacific of the City LA QUINTA Your Westpac Heating and Air Conditioning system is ready for MEPS inspection. If you have any questions or concerns regarding this lot, please contact us at (951) 73979501. "Working as a Team to be the Best in our.Industry" ci . 19 INSTALLA TE 3 of 13) CF -6R /C f t2 -9e3 Site Address' Permit Number DUCT LEAKAGE AND DESIGN DIAGNOSTICS fJ DUCT LEAKAGE r1ori .Pfftsurization Test Results (CFM @ 25 PA) Fan Flow Test Leakage (CFM) If Fan Flow Is Calculated as 40() cfinftm x number of tons, of as 21.7 x Heating capacity in Thousands. of BtuAhr, enter calculated value hem Leakage Fraction If fen flow Is measured, enter measured value here Test Lwk890((M=ured Or Calculated Fa - n Flow)= Pass if leakage fmclion!5 0.06 13 trorARROSOL TYPE SEALANTS ONLY - ne follewhig dimpos& testing VMS completedh Duct Fen Pressurization at rough -in measured leakage (CFM) CHECK AFTER FINISHING WALL: 11yes 0 No 11 Pressure pan test or House pressurization test 13 Yes 11 No - 0 Visual Inspection of Duct Connections Pass Fail inrvKrnVtfVATIC EXPANSION VALVE aXV) Yes No Thermostatic Expansion Valve is installed and Access is provided for Inspection Age Yes Is a pass P Fall 13 DUCT DESIGN 1. Yes- [3 No ACCA Mabual D Design caicuhntions (lave been completed, Duct Design Is on the plans and duct Installation matches plow. 2. Yes 13 No 7XV Is Installed or Fan flow has been verified. If no 7XV, verified fan flow matches design from CF -IR. Measured Fen Flow 11 Yes for both I and 2 is a Pass 13 Pass Fail the InWwftned, verify that the above diagnostic test results and the Work I performed assodsted.with. the teft) is in with the'requirements for compliance credit. Me builder shall provide the HERS providem a copy-ofthe CF -'6R signed by the builder employees or sub-oontractorg ca*ing that diagnostic testing and 1118tRilation meet the requiremairts for compliance credit /01 Tests Migodwe, Date zLta/0_77-_ Performed Installing.Subcontrectur (Co. �e) OR� -COPY TO: Building Department General Contractor (Co. Name 'HERS Provider (if applicable) Building Owner at Occupancy CompHande Forms August 2001 A-25 INSTALLATION CERTIFICATE (Page 3 of 13) CF -6R -�57 s Site Address Permit Number DUCT LEAKAGE AND DESIGN DIAGNOSTICS DUCT LEAKAGE REDUCTION .rTssurizat'on Test Results (CFM ® 25 PA) Test Leakage (CFM) Fen Flow If Fan Flow is Calculated as 400 cfm/ton x number of tons, or as 21.7 x Heating Capacity / �1 in Thousumcls.of Btu/hr, enter calculated vahn here [ If fan flow is measured, enter measured value here Leakage Fraction = Test Leakage/(Measured or Catcuh+ted Fan Flow) _ Pass if leakage fraction 5 0.060 ❑ t ror AEROSOL TYPE SEALANTS ONLY - The following diapostic testing was completed: Paas Fail Duct Fan Pres uization at rough -in measured leakage (CFM) CHECK AFTER FINISHING WALL: ❑ Yes ❑ No ❑ Pressure pan tester House press rization test Q Yes ❑ No ❑ Visual Inspection of Duct Connections ❑ 13, Pass Fail. THERMOSTATIC EXPANSION VALVE Yes ❑ No Thermostatic Expansion Valve is installed and Access is Ap provided for inspection ❑ Yes is a pass P Fail 0 DUCT DESIGN I ❑ Yes. ❑ No ACCA Manual D Design calculations have been completed, Duct Design is on the plans atui dud Installation matches plans. 2. ❑ Yes ❑ No TXV is installed or Fan flow has been verified. If no TXV, verified fie flow matches design from CF -IR. Measured Fan Flow = ❑ ❑ ,. Yes for both 1 and 2 is a Pass Pass Fall I, the undersigned, ver* that the above diagnostic test results and the work i paa%stned assoeided.with fire lest(s) is in LAX*Wce with the'requhaneda for compliance credit. [The builder small provide the HERS provider a copy of the CF -611 signed by the builder employes or sub-conlradars certifying that diagnostic testing and installation meet the tegtti wNx is for compliance cx!edit.] Tests gnature, Date Installing Subcontractor (Co. Name) OR Performed General Contractor (Co. Name) COPY TO: Building Deparhnad HERS Provider (if applicable) Building Owner at Occupancy Compliande Forms August 2001 A-25 co') Certificate'of Occu ancy 11 0 _�,P V. 9� OFT1 Building &Safety Department Y. S'J XT E" This Certificate is issued pursuant to the requirements of Section 109 of the California Building Code, certifying' that, at the time of issuance' this structure' was in compliance with the 4 provisions of the Building Code and the various ordinances of the City regulating building construction and/or use. BUILDING ADDRESS: 57- 685 ROSEWOOD COURT Use classification: SFD Building Permit No.: 07-1187 Occupancy Group: R-3 Type of Construction: VN Land Use Zone: RL Owner of Building: STANDARD PACIFIC HOMES Address: 1717 E. VISTA CHINO RD, STE A7 City, ST, ZIP: PALM SPRINGS, CA. By: KIRK KIRKLAND Date: NOVEMBER 7, 2007 Building Official POST IN A CONSPICUOUS PLACE