06954 (SFD)Building
AtfrlrPcc 49-010 Balada Court
Owner
BRRCON DEVELOPMENT
Mailin
Address 68-713 Perez Road, 11
city Cathedral Ci
Contractor
city lZip I Tel.
P.O. BOX 1504
78-105 CALLE ESTADO
LA QUINTA, CALIFORNIA 92253
State Lic. 337€77IGity 1219
& Classif. Lic. #
Arch., Engr.,
Designer
Address
City r (Zip (State
Lic. #
LICENSED CONTRACTOR'S DECLARATION
I Hereby affirm that I am licensed under Provisions of Chapter 9 (commencing with Section
7000) of irision 3 of the Business and Professions Code, and my license is -in full/}orce and
effect, .i /*w
SIGNATURE f ` DATE
OWNEWBUILDER DECLARATION
1 hereby affirin that I am exempt from the Contractor's License Law for the following
reasom (Sec. 7031.5,13usiness and Professions Code: Any city or county which requires a
perm to construct, after, improve, demolish 'or repair any structure, prior to its issuance also
requires the appicant for such permit to f&a signed statement that he is licensed pursuant to
the provisions of the Contractor's License Law, Chapter 9 (commencing with Section 7000) of
00vision 3 of the Business and Professions Code, or that. he is exempt therefrom, and the basis
for the alleged exemption. Any violation of Section 7031.5 by 'any applicant for a permit
subjects the appicard to a civil penalty of not more than five hundred dollars ($500).
O 1, as owner of the property, or employees mployees with wages as their sole compensation, will
do the work, and the structure is not intended or offered for sale. (Sec. 7044, Buisness and
Professions Code. The Contradoes License Law does not apply to an owner of property who
bulls or improves thereon and who does such work himself or through his own employees,
provided that such improvements are not intended or offered for sale. If, however, the building
or irprovement rs sold wf ttb one year of completion, the owner -builder will have the burden
of proving that he did not build or improve for the purpose of sale.)
O I, as owner of the property, am exclusively contracting with licensed contractors to con-
struct the project (Sec. 7044, Business and Professions Code: The Contractor's License Law
does not appy, to an owner of property who bunds or improves thereon, and who contracts for
such projects with a eontrador(s) icensed putsuant to the Contractor's License Law.)
O 1 am exempt under Sec B. & P.C. for this reason
Date Owner
WORKERS' COMPENSATION DECLARATION
I hereby affirm that I have a certificate of consent to self -insure, or a certificate of
Workers Compensation Insurance, or a certified copy thereof. (Sec. 3800, Labor Code.)
Policy No Company
O Copy is filed with the city. O Certified copy is hereby furnished.
CERTIFICATE OF EXEMPTION FROM
t WORKED' COMPENSATION INSURANCE
(This section need not be completed ff the permit is for one hundred dollars ($100) valuation
or less.) I
I certify that in the performance of thg work for which this permit is issued, I shall not
employ
any person in`any manner so as to become subject to the Workers' Compensation
Laws of California
Date Owner
N077CE TO APPLICAffr.ff, after making this Certificate of Exemption you should become
subject to the workers' Compensation provisions of the Labor Code, you must forthwith
comply with such provisions or Ifus permit shall be deemed revoked.
CONSTRUCTION LENDING AGENCY
hereby affirm that there is a construction lending agency for the performance of the
work for which this permit is issued. (Sec. 3097, Civil Code.)
Lenders Name
Lenders Address
This is a building permit when properly filled out, signed and validated, and is subject to
expiration "If work thereunder is suspended for 180 days.
I certify that I have read this application and state that the above information is correct.
I agree to comply with all city and county ordinances and state laws relating to building
construction, and whereby authorize representatives -of this city to enter the above-.
mentioned property for inspection purposes.
Signature of applicant Date
Mailing Address
City,. State, Zip
No. 46954
BUILDING: TYPE CONST. OCC; GRP.
Tract B-ys Y fes
A.P. Number
Legal Description
PARC LA QUI11TA
Project Description
Pian 1740 M. Lot #25
Sq. Ft. 1,740
Size
No. No. Dw.
Stories Units
New Add ❑ Alter ❑ Repair ❑
Demolition ❑
Estimated Valuation
$83,574
PERMIT
AMOUNT
Plan Chk. Dep.
Plan Chk. Bal.
494.25
Const.
590.00
Mech.
66.50
Electrical
102.60
Plumbing
120.50
S.M.I.
1.23
Grading
Driveway Enc.
Infrastructure
11992.32
TOTAL
3,3 3.00 ,/
REMARKS
AnIC4 N? P. {77rt r1f .-' A_A- ii f 0
1.EI - t.H;.t� i tt it7i_ L
as+a.rl
ZONE: BY:
Minimum Setback Distances:
Front Setback from Center Line
Rear Setback from Rear Prop. Line
Side Street Setback from Center Line
Side Setback from Property Line
FINAL DATE INSPECTOR
Issued by: Date Permit
Validated by:
Validation:
CONSTRUCTION ESTIMATE
NO. ELECTRICAL FEES
NO. PLUMBING FEES
1ST FL. SQ. FT. ® $
UNITS
COLL. AREA
SLAB GRADE Z �[ O
ROUGH PLUMB.'
YARD SPKLR SYSTEM
2ND FL SQ. FT. @
HEATING (ROUGH)
STORAGE TANK
FORMS
MOBILEHOME SVC.
BAR SINK
POR. SO. FT, ®
ROCK STORAGE
FOUND. REINF.
GAR. SO. FT. ®
POWER OUTLET
ROOF DRAINS
HEATING (FINAL)
OTHER APPJEQUIP.
DRAINAGE PIPING
CAR P. SO, FT, ®
TEMP. POLE
WALL SO. FT. ®
DRINKING FOUNTAIN
SQ FT ®
SERVICE
URINAL
ESTIMATED CONSTRUCTION VALUATION $
WATER PIPING
NOTE: Not to be used as property tax valuation
FINAL INSP. .
FLOOR DRAIN
MECHANICAL FEES
WATER SOFTENER
VENT SYSTEM FAN EVAP.COOL HOOD
SIGN
WASHER(AUTO)(DISH)
APPLIANCE DRYER
n
�?j (,�J
GARBAGE DISPOSAL
FURNACE UNIT WALL FLOOR SUSPENDED
LAUNDRY TRAY
AIR HANDLING UNIT CFM
VENTILATION
KITCHEN SINK
ABSORPTION SYSTEM B.T.U.
TEMP USE PERMIT SVC
WATER CLOSET
COMPRESSOR HP
POLE, TEM/PERM
LAVATORY
HEATING SYSTEM FORCED GRAVITY
AMPERES SERV ENT
SHOWER
BOILER B.T.U.
SO. FT. ® c
BATH TUB
SQ. FT. ® c
WATER HEATER
MAX. HEATER OUTPUT, B.T.U.
SO. FT. RESID ® 11/. c
SEWAGE DISPOSAL
SO.FT.GAR ® a/<c
HOUSE SEWER
MESH
GAS PIPING
PERMIT FEE
PERMIT FEE
PERMIT FEE
DBL
TOTAL FEES
MICRO FEE
MECH.FEE PL.CK.FEE
CONST. FEE ELECT. FEE
SMI FEE PLUMB. FEE
STRUCTURE PLUMBING ELECTRICAL HEATING & AIR COND. SOLAR
SETBACK �( %� W
GROUND PLUMBING Z !S�
(l NDERGROUND
A.C. UNIT
COLL. AREA
SLAB GRADE Z �[ O
ROUGH PLUMB.'
BONDING
HEATING (ROUGH)
STORAGE TANK
FORMS
SEWER OR SEPTIC TANK
/,
ROUGH WIRINGY l/ q6
(
DUCT WORK
ROCK STORAGE
FOUND. REINF.
GAS (ROUGH)
METER LOOP
HEATING (FINAL)
OTHER APPJEQUIP.
REINF. STEEL
GAS (FINAL)
TEMP. POLE
GROUT
WATER HEATER
SERVICE
FINAL INSP.
BOND BEAM
WATER SYSTEM
FINAL INSP. .
2,J
J
GRADING
cu. yd.
$ -Plus-X$-=$
LUMBER GR.
FRAMING �C Rar
FINAL INSP.
ROOFING
n
�?j (,�J
// / !td
�J
REMARKS:
VENTILATION
FIRE ZONE ROOFING '
FIREPLACE
SPARK ARRESTOR
GAR. FIREWALL
MESH
INSULATION/SOUND
FINISH GRADING
FINAL INSPECTION O� d
CERT. OCC.
FENCE FINAL
INSPECTOR'S SIGNATURESIINITIALS
GARDEN WALL FINAL
t
1N3 d013A3a kLINnww0�
. NInb `d130 kLI:)
MOZ9483.E
G FFK(Tr1(oP
BUILDING ENERGY ANALYSIS REPORT
PROJECT:
Gipson Residence
49-010 Balado Court
La Quinta, CA
Project Designer:
Lench Design Studio
78215 Calle Cadiz
La Quinta, Ca 92253
760-564-1860
Report Prepared by:
Joan D. Hacker
Insu-form, Inc.
77810 Las Montanas Road, Suite 201
Palm Desert, Ca 92211
760-345-1352
Job Number:
Date:
IIA1303d
2/4/2014 C::;F
F Qin i 6�JT�q
�
The EnergyPro computer program has been used to perform the calculations summarized in thiarepor�fT,lalsaprtogpaMa�ap pro al and is
authorized by the California Energy Commission for use with both the Residential and Nonres8 Building Energ�%Efficle crSta dards.
RO ✓EDThis program developed by EnergySoft, LLC — ION
�w.enINSTRUCTEne Pro 5.1 6 Ene Soft User Number: 2655 RunCode: 2014-02-04T1 :13:02DATEBY 4`
1
PERFORMANCE CERTIFICATE: Residential Part 1 of 5
CF-1 R
Project Name
Gipson Residence
Building Type m Single Family ❑ Addition Alone
❑ Multi Family ® Existing+ Addition/Alteration
Date
2/4/2014
Project Address
49-010 Balado Court La Quinta
California Energy Climate Zone
CA Climate Zone 15
Total Cond. Floor Area
1,785
Addition
45
# of Stories
1
FIELD INSPECTION ENERGY CHECKLIST
❑ Yes IZI No HERS Measures -- If Yes, A CF-4R must be provided per Part 2 of 5 of this form.
❑ Yes ❑ No Special Features -- If Yes, see Part 2 of 5 of this form for details.
INSULATION
Construction Type
Area Special
Cavity Features see Part 2 of 5 Status
Slab Unheated Slab-on-Grade
None 1,740 Perim = 125' Existing
Wall Wood Framed
R-11 1,430 Existing
Door Opaque Door
None 20 Existing
Roof Wood Framed Attic
R-19 1,740 Existing
Roof Wood Framed Attic
R-38 45 New
Wall Wood Framed
R-13 333 New
Slab Unheated Slab-on-Grade
None 45 Perim = 18' New
FENESTRATION U-
Orientation Area Factor
Exterior
SHGC Overhang Sidefins Shades Status
Front (W) 68.0 0.710
0.73 2.0 none Bug Screen Existing
Left (N) 12.0 0.710
0.73 2.0 none Bug Screen Existing
Rear (E) 44.4 0.710
0.73 2.0 none Bug Screen Removed
Rear (E) 44.4 0.710
0.73 2.0 none Bug Screen Existing
Right (S) 16.0 0.710
0.73 2.0 none Bug Screen Existing
Right (S) 15.0 0.710
0.73 2.0 none Bug Screen Removed
Right (S) 20.0 0.710
0.73 2.0 none Bug Screen New
Rear (SE) 10.0 0.710
0.73 2.0 none Bug Screen Removed
Left (N) 18.0 0.590
0.45 2.0 none Bug Screen New
Rear (SE) 49.0 0.590
0.45 2.0 none Bug Screen New
HVAC SYSTEMS
Ot . Heating Min. Eff Cooling Min. Eff Thermostat Status
1 Central Furnace 80% AFUE Split Air Conditioner 12.0 SEER Setback
Existing
HVAC DISTRIBUTION
Location Heating
Duct
Cooling Duct Location R-Value Status
Existing House Ducted
Ducted Attic, Ceiling Ins, vented 4.2
Existing
WATER HEATING CITY OF LA QU11ITA�
Ot . Type Gallons Min. Eff Dist libution,,,���. o r ,,, pr-%ptu„s
/"- ►1� i- hi i '1f L LJ
1-1
Y Y ,e 31 �l I i lli
V V
Ener Pro 5.1 by Ener Soft User Number. 2655 Run Code: 2014-02-04T13:1 ,,02*C -lam:
Page 3 of 12
PERFORMANCE CERTIFICATE: Residential Part 2 of 5) CF -1 R
Project Name
Gipson Residence
Building Type ® Single Family ❑ Addition Alone
1 ❑ Multi Family ® Existing+ Addition/Alteration
Date
2/4/2014
SPECIAL FEATURES INSPECTION CHECKLIST
The enforcement agency should pay special attention to the items specified in this checklist. These items require special written
justification and documentation, and special verification to be used with the performance approach. The enforcement agency
determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of
the special justification and documentation submitted.
HERS REQUIRED VERIFICATION
Items in this section require field testing and/or verification by a certified HERS Rater. The inspector must receive a
completed CF -4R form for each of the measures listed below for final to be given.
CITY OF LA C UINTA
DUILujlviU & 5Ht-t I Y DEPT.
FOR CONSTRUCTION
Ener Pro 5.1 by Ene Soft User Number: 2655 RunCode: 2014-02-04T13:13:02 ID: Pa e 4 of 12
l DATE --- gy
- I
CA
PERFORMANCE CERTIFICATE: Residential Part 3 of 5 CF -1 R
Project Name
Building Type m Single Family ❑ Addition Alone
Date
Gipson Residence
1 ❑ Multi Family m Existing+ Addition/Alteration
2/4/2014
ANNUAL ENERGY USE SUMMARY
Standard Proposed Margin
TDV kBtu/ft2- r
Space Heating 8.94 8.23 0.72
Space Cooling 127.52 121.41 6.11
Fans 28.12 26.75 1.37
Domestic Hot Water 19.67 19.67 0.00
Pumps 0.00 0.00 0.00
Totals 184.25 176.05 8.20
Percent Better Than Standard: 4.4%
BUILDING COMPLIES - NO HERS VERIFICATION REQUIRED
Fenestration
Building Front Orientation: (tM 270 deg Ext. Walls/Roof Wall Area Area
Number of Dwelling Units: 1.00 (W 320 68
Fuel Available at Site: Natural Gas (N) 620 30
Raised Floor Area: 0 (E) 710 93
Slab on Grade Area: 1.785 (S) 360 36
Average Ceiling Height: 10.0 Roof 1,785 0
Fenestration Average U -Factor: 0.67 TOTAL: 227
Average SHGC: 0.65 Fenestration/CFA Ratio: 12.7%
REMARKS
STATEMENT OF COMPLIANCE
This certificate of compliance lists the building features and specifications needed
to comply with Title 24, Parts 1 the Administrative Regulations and Part 6 the
Efficiency Standards of the California Code of Regulations.
The documentation author hereby certifies that the documentation is accurate and complete.
Documentation Author
Company Insu-form, Inc.
2/ 2 14
Address 77810 Las Montanas Road, Suite 201 Name Joan D. Hacker
City/State/ZipCity/State/Zip Palm Desert, Ca 92211 Phone 760-345-1352 sigLdi Date
The individual with overall design responsibility hereby certifies that the proposed building design represented in this set
of construction documents is consistent with the other compliance forms and worksheets, with the specifications, and
with any other calculations submitted with this permit application, and recognizes that compliance using duct design,
duct sealing, verification of refrigerant charge, insulation installation quality, and building envelope sealing require
installer testing and certification and field verification by an approved HERS rater,----. _
Designer or Owner (per Business & Professions Code) C1 F LIA NT
.!
Company Lench Design Studio BUI NG & S �tFl: p T-,
� �%
Address 78215 Calle Cadiz NameLl 1
1.
f . a.r
City/State/Zip La Quinta, Ca 92253 Phone 760-564-1860 igned�Icgcq.tj#}R746 N Date
Ener.qyft 5.1 by Ener Soft User Number: 2655 RunCode: 2014-02-04713:13:02 BY Pa e 5 of 121
CERTIFICATE OF COMPLIANCE:
Residential Part 4 of 5 CF-1 R
Project Name
Gipson Residence
Building Type m Single Family ❑ Addition Alone
❑ Multi Family la Existing+ Addition/Alteration
Date
214/2014
OPAQUE SURFACE DETAILS
Surface
Type Area
U Insulation
Factor I Cavity I Exterior Frame Interior Frame Azm
Joint Appendix
Tilt I Status 4 Location/Comments
Slab
1,740
0.730 None
0
180 Existing 4.4.7-A1
Existing House
Wall
252
0.110 R-11
270
90 Existing 4.3.1-A2
Existing House
Wall
408
0.110 R-11
0
90 Existing 4.3.1-A2
Existing House
Wall
346
0.110 R-11
90
90 Existing 4.3.1-A2
Existing House
Door
20
1.450 None
90
90 Existing 4.5.1-A1
Existing House
Wall
324
0.110 R-11
180
90 Existing 4.3.1-A2
Existing House
Roof
1,740
0.049 R-19
270
0 Existing 4.2.1-A4
Existing House
Wall
330
0.110 R-11
90
90 Removec 4.3.1-A2
Existing House
Wall
100
0.110 R-11
135
90 Existing 4.3.1-A2
Existing House
Roof
45
0.025 R-38
270
0 New 4.2.1-A21
Addition
Wall
182
0.102 R-13
0
90 New 14.3.1-A3
Addition
Slab
45
0.730 None
0
180 New - 4.4.7-A1
Addition
Wall
1511
0.102 R-13
135
90 New 4.3.1-A3
Addition
FENESTRATION SURFACE DETAILS
ID
Type
Area U-Factor
SHGC2
Azm Status
Glazing Type
Location/Comments
1
Window
24.0 0.710 Default
0.73 Default
270 Existing
Double Metal Clear
Existing House
2
Window
12.0 0.710 Default
0.73 Default
270 Existing
Double Metal Clear
Existing House
3
Window
16.0 0.710 Default
0.73 Default
270 Existing
Double Metal Clear
Existing House
4
Window
16.0 0.710 Default
0.73 Default
270 Existing
Double Metal Clear
Existing House
5
Window
12.0 0.710 Default
0.73 Default
0 Existing
Double Metal Clear
Existing House
6
Window
33.4 0.710 Default
0.73 Default
90 Removed Double Metal Clear
Existing House
7
Window
2.0 0.710 Default
0.73 Default
90 Existing
Double Metal Clear
Existing House
8
Window
9.0 0.710 Default
0.73 Default
90 Existing
Double Metal Clear
Existing House
9
Window
33.4 0.710 Default
0.73 Default
90 Existing
Double Metal Clear
Existing House
10
Window
11.0 0.710 Default
0.73 Default
90 Removed Double Metal Clear
Existing House
11
Window
16.0 0.710 Default
0.73 Default
180 Existing
Double Metal Clear
Existing House
12
Window
15.0 0.710 Default
0.73 Default
180 Removed Double Metal Clear
Existing House
13
Window
20.0 0.710 Default
0.73 Default
180 New
Double Metal Clear
Existing House
14
Window
10.01 0.710 Default
0.73 Default
135 Removed Double Metal Clear
Existing House
15
Window
9.01 0.590 NFRC
0.45 NFRC
0 New
IWC 6200 Alurnkow-E
Addition
16
Window
9.01 0.590 1 NFRC
1 0.45 NFRC
0 New
IWC 6200 Alum/Low-E
Addition
(1) Ll-Factor Type: 116-A = Default Table from Standards, NFRC = Labeled Value
2 SHGC Type: 116-B = Default Table from Standards, NFRC = Labeled Value
EXTERIOR SHADING DETAILS
ID
'Exterior Shade Type SHGC
Window
Hot Wd
Ove hang Left Fin
Len Hot LExt I RExt Dist Len
Right Fin
Hot Dist Len Hot
1
Bug Screen
0.76
4.0 6.0
2.0 0.1
2.0 2.0
2
Bug Screen
0.76
6.0 1.0
2.0 0.1
2.0 2.0
3
Bug Screen
0.76
4.0 4.0
2.0 0.1
2.0 2.0
4
Buq Screen
0.76
4.0 4.0
2.0 0.1
2.0 2.0
5
Bug Screen
0.76
6.0 1.0
2.0 0.1
2.0 2.0
6
Bug Screen
0.76
6.8 8.0
2.0 0.1
2.0 2.0
7
Bug Screen
0.76
1.0 2.0
2.0 0.1
2.0 2.0
8
Bug Screen
0.76
3.0 3.0
2.0 0.1
2.0 2.0
9
Bug Screen
0.76
3.0 3.0
2.0 0.1
2.0 2.0
10
Bug Screen
0.76
3.0 3.0
2.0 0.1
2.0 2.0
11
Bug Screen
0.76
4.0 4.0
2.0 0.1
2.0 2.0
12
Bug Screen
0.76
3.81 4.0
2.0 0.1
2.0 2.0 I ^
'--
13
Bug Screen
0.76
6.8 3.0
2.0 0.1
2.0 2.0 N 1. I I i (.i!1r-
14
Bug Screen
0.76
4.0 3.0
2.0 0.1
= .� r-y
2.0 2.0 I Rf A A mir+ o
15
Bug Screen
0.76
4.51 2.0
2.0 0.1
2.0 2.0 I
``��L - t Y U t:
16
Bu Screen
0.76
4.5 2.0
2.0 0.1
2.0 2.0 1 -
P Q ��, .1
FOR CONSTRUCTION
Ener Pro 5.1 b Ener Soft User Number: 2655 Run Code: 2014-02-04T13:13:02 ID:
Pa e 6 of 1
CERTIFICATE OF COMPLIANCE: Residential
Part 4 of 5 CF -1 R
Project Name
Gipson Residence
Building Type m Single Family
❑ Multi Family
❑ Addition Alone
m Existing+ Addition/Alteration
Date
2/4/2014
OPAQUE SURFACE DETAILS
Surface U- Insulation
Type Area Factor Cavity Exterior Frame Interior Frame Azm Tilt Status
Joint Appendix
4 Location/Comments
FENESTRATION SURFACE DETAILS
ID Toe Area U -Factor SHGC2 Azm Status Glazinq Type Location/Comments
17 Window 9.0 0.590 1 NFRC 0.45 NFRC 135 New IWC 6200 AlumA-ow-E Addition
18 Window 40.0 0.5901 NFRC 0.45 NFRC 135 New IWC 6200 Alum/Low-E Addition
(1) LI -Factor Type: 116-A =Default Table from Standards, NFRC =Labeled Value
2 SHGC Type: 116-B = Default Table from Standards, NFRC = Labeled Value
EXTERIOR SHADING DETAILS
Window Ove hanq
ID Exterior Shade Type SHGC H t Wd Len Hot I LExt RExt
Left Fin Ri ht Fin
Dist Len H t Dist Len I H t
17 Bug Screen 0.76 3.0 3.0 2.0 0.11 2.0 2.0
18 Bug Screen 0.76 6.8 6.0 2.0 0.1 2.0 2.0
N C ,i 1/ -)iz f A fM fIN[ p is I
I ILLIYI Yla fX OP.,'1: 17-- I , A
M 1-n i'%,* x r- r1
v r- Y Y YY L i `6Y L._ L -y
EnergyPro 5.1 by EnerqySoft User Number. 2655 Run Code: 2014-02-04713:13:02 N
nd0j= Page 7 of 1
CERTIFICATE OF COMPLIANCE: Residential Part 5 of 5
CF-1 R
Project Name
Gipson Residence
Building Type ❑ Single Family ❑ Addition Alone
❑ Multi Family ❑ Existing+ Addition/Alteration
Date
214/2014
BUILDING ZONE INFORMATION
System Name Zone Name
Floor Area ft
New Existing Altered Removed Volume Year Built
Existing House Existing House
1,740
17,400 1980
Addition
45
450
Totals 45 1,740 0 0
HVAC SYSTEMS
System Name Qty. I Heating Type
Min. Eff. Cooling Type Min. Eff. Thermostat Type Status
Existing House 1 I Central Furnace
80% AFUE Split Air Conditioner 12.0 SEER Setback
Existing
HVAC DISTRIBUTION
System Name Heating
Duct
Cooling Duct Location R-Value
Ducts
Tested? Status
Existing House Ducted Ducted Attic, Ceiling Ins, vented 4.2
❑ Existing
❑
WATER HEATING SYSTEMS
S stem Name
Qty.
Type
Distribution
Rated
Input
Btuh
Tank
Cap.
al
Energy
Factor
or RE
Standby
Loss or
Pilot
Ext.
Tank
Insul. R-
Value
Status
Standard Gas 50 gal or Le
1
Small Gas
No Pipe Insulation
40,000
50
0.53
n/a
n/a
Existing
MULTI-FAMILY WATER
HEATING
DETAILS
HYDRONIC
HEATING
SYSTEM PIPING
Control
Hot Water Piping Length
ft
c
0
id
v U)
¢ —
Pipe
System Name Len th
Pipe Insul.
Diameter Thick.
Qty. HP
Plenum Outside Buried
❑
VI
❑
BU
❑
r� �-,
'
❑
r r r-t
I-UFi UONSTRUCTION
Ener Pro 5.1 by EnergySoft User Number. 2655
RunCode: 2014.02-04T13:13:0 ID:
Page 811`712
I DATE BY I
MANDATORY MEASURES SUMMARY: Residential Pae 1 of 3 MF -1 R
Project Name
Date
Gipson Residence
1 2/4/2014
NOTE: Low-rise residential buildings subject to the Standards must comply with all applicable mandatory measures listed, regardless of
the compliance approach used. More stringent energy measures listed on the Certificate of Compliance (CF -1 R, CF -1 R -ADD, or CF -
1 R -ALT Form) shall supersede the items marked with an asterisk (') below. This Mandatory Measures Summary shall be incorporated
into the permit documents, and the applicable features shall be considered by all parties as minimum component performance
specifications whether they are shown elsewhere in the documents or in this summary. Submit all applicable sections of the MF -1 R
Form with plans,
Building Envelope Measures:
116(a)l: Doors and windows between conditioned and unconditioned spaces are manufactured to limit air leakage.
§116(a)4: Fenestration products (except field -fabricated windows) have a label listing the certified U -Factor, certified Solar Heat Gain
Coefficient SHGC and infiltration that meets the requirements of 10-111 (a).
117: Exterior doors and windows are weather-stripped; all joints and penetrations are caulked and sealed.
118(a): Insulationspecified or installed meets Standards for Insulating Material. Indicate type and include on CF -6R Form.
§118(1): The thermal emittance and solar reflectance values of the cool roofing material meets the requirements of §118(1) when the
installation of a Cool Roof is specified on the CF -1 R Form.
150(a): Minimum R-19 insulation in wood -frame ceiling orequivalent U -factor.
§150(b): Loose fill insulation shall conform with manufacturer's installed design labeled R -Value.
150 c : Minimum R-13 insulation in wood -frame wall orequivalent U -factor.
*§1 50 d : Minimum R-13 insulation in raised wood -frame floor orequivalent U -factor.
.4150(f): Air retarding wrap is tested labeled and installed according to ASTM E1677-95 2000 when specified on the CF -1 R Form.
150 : Mandatory Vapor barrier installed in Climate Zones 14 or 16.
§150(1): Water absorption rate for slab edge insulation material alone without facings is no greater than 0.3%; water vapor permeance
rate is no greater than 2.0perm/inch and shall be protected from physical damage and UV light deterioration.
Fireplaces, Decorative Gas Appliances and Gas Log Measures:
150(e)IA: Masonry or factory -built fireplaces have a closable metal or glass door covering the entire opening of the firebox.
§150(e)1 B: Masonry or factory -built fireplaces have a combustion outside air intake, which is at least six square inches in area and is
equipped with a with a readily accessible, operable, and tight -fitting damper and or a combustion -air control device.
§150(e)2: Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the
outside of the building, are prohibited.
Space Conditioning, Water Heating and Plumbing System Measures:
§110-§113: HVAC equipment, water heaters, showerheads, faucets and all other regulated appliances are certified by the Energy
Commission.
§113(c)5: Water heating recirculation loops serving multiple dwelling units and High -Rise residential occupancies meet the air release
valve, backflow prevention, pump isolation valve, and recirculation loop connection requirements of §113(c)5.
§115: Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces, household cooking appliances
(appliances with an electrical supply voltage connection with pilot lights that consume less than 150 Btu/hr are exempt), and pool and
spa heaters.
150(h): Heating and/or cooling loads are calculated in accordance with ASHRAE, SMACNA or ACCA.
150(i): Heating systems are equipped with thermostats that meet the setback requirements of Section 112(c).
§1500)1 A: Storage gas water heaters rated with an Energy Factor no greater than the federal minimal standard are externally wrapped
with insulation having an installed thermal resistance of R-12 or greater.
§1500)113: Unfired storage tanks, such as storage tanks or backup tanks for solar water -heating system, or other indirect hot water
tanks have R-12 external insulation or R-16 internal insulation where the internal insulation R -value is indicated on the exterior of the
tank.
§150(j)2: First 5 feet of hot and cold water pipes closest to water heater tank, non -recirculating systems, and entire length of
recirculating sections of hot water pipes are insulated per Standards Table 150-13.
§150(j)2: Cooling system piping (suction, chilled water, or brine lines),and piping insulated between heating source and indirect hot
water tank shall be insulated to Table 150-B and Equation 150-A.
§1500)2: Pipe insulation for steam hydronic heating systems or hot water systems >15 psi, meets the requirements of Standards Table
123-A.
§150(j)3A: Insulation is protected from damage, including that due to sunlight, moisture—,equip eflt-maintenans
§1500)3A: Insulation for chilled waterand refrigerant suction lines includes a v�a
piping 9
r etardan o is e c 6se tiFe
` p� d r O Y' Uc 6s �� yV�/-f,
conditioned space.
§150(j)4: Solar water-heatingsystems and/or collectors are certified b the Solar matin
C u l k. !l Jv k-1
and Certification rgti n. DEP I.
AHHHUVED
FOR CONSTRUCTION
EnergyPro 5.1 by EnergySoft User Number: 2655 RunCode: 2014-02-04713:13:02
ID: Page 9
of 12
DATE By
MANDATORY MEASURES SUMMARY: Residential (Page 2 of 3 MF -1 R
Project Name
Date
Gipson Residence
2/4/2014
§150(m)1: All air -distribution system ducts and plenums installed, are sealed and insulated to meet the requirements of CMC Sections
601, 602, 603, 604, 605 and Standard 6-5; supply -air and return -air ducts and plenums are insulated to a minimum installed level of R-
4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct -closure system that meets the
applicable requirements of UL 181, UL 181 A, or UL 181 B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is
used to seal openings reater than 1/4 inch, the combination of mastic and either mesh or tape shall be used
§150(m)1: Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed
sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may
contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area
of the ducts.
§150(m)2D: Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes
unless such tape is used in combination with mastic and draw bands.
150(m)7: Exhaust fans stems have back draft or automatic dampers.
§150(m)8: Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated
dampers.
§150(m)9: Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind.
Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar
radiation that can cause de radation of the material.
150 m 10: Flexible ducts cannot have porous inner cores.
§150(o): All dwelling units shall meet the requirements of ANSI/ASHRAE Standard 62.2-2007 Ventilation and Acceptable Indoor Air
Quality in Low -Rise Residential Buildings. Window operation is not a permissible method of providing the Whole Building Ventilation
required in Section 4 of that Standard.
Pool and Spa Heating Systems and Equipment Measures:
§114(a): Any pool or spa heating system shall be certified to have: a thermal efficiency that complies with the Appliance Efficiency
Regulations; an on-off switch mounted outside of the heater; a permanent weatherproof plate or card with operating instructions; and
shall not use electric resistance heating ora pilot light.
§114(b)1: Any pool or spa heating equipment shall be installed with at least 36" of pipe between filter and heater, or dedicated suction
and return lines, or built-up connections for future solar heating.
114(b)2: Outdoor pools ors as that have a heat pump or gas heater shall have a cover.
§114(b)3: Pools shall have directional inlets that adequately mix the pool water, and a time switch that will allow all pumps to be set or
programmed to run only during off-peak electric demand periods.
150 : Residential pool systems orequipment meet the pump sizing, flow rate, piping, filters, and valve requirements of §150
Residential Lighting Measures:
§150(k)1: High efficacy luminaires or LED Light Engine with Integral Heat Sink has an efficacy that is no lower than the efficacies
contained in Table 150-C and is not a low eff icacy luminaire asspecified by §150(k)2.
§150(k)3: The wattage of permanently installed luminaires shall be determined asspecified by §130(d).
§150(k)4: Ballasts for fluorescent lamps rated 13 Watts or greater shall be electronic and shall have an output frequency no less than
20 kHz.
§150(k)5: Permanently installed night lights and night lights integral to a permanently installed luminaire or exhaust fan shall contain
only high efficacy lamps meeting the minimum efficacies contained in Table 150-C and shall not contain a line -voltage socket or line -
voltage lamp holder; OR shall be rated to consume no more than five watts of power as determined by §130(d), and shall not contain a
medium screw -base socket.
150(k)6: Lighting integral to exhaust fans, in rooms other than kitchens, shall meet the applicable requirements of §150(k).
150(k)7: All switching devices and controls shall meet the requirements of §150(k)7.
§150(k)8: A minimum of 50 percent of the total rated wattage of permanently installed lighting in kitchens shall be high efficacy.
EXCEPTION: Up to 50 watts for dwelling units less than or equal to 2,500 ff2 or 100 watts for dwelling units larger than 2,500 ft2 may be
exempt from the 50% high efficacy requirement when: all low efficacy luminaires in the kitchen are controlled by a manual on occupant
sensor, dimmer, energy management system (EMCS), or a multi -scene programmable control system; and all permanently installed
luminaries in garages, laundry rooms, closets greater than 70 square feet, and utility rooms are high efficacy and controlled by a
manual -on occupant sensor.
§150(k)9: Permanently installed lighting that is internal to cabinets shall yse no more than 20-watts=of-power per-limeaf- foot of
illuminated cabinet. I GITY OF I Ani l A K 17-
BUILDING & SAFETY DEPT.
A 1—
FOR CONSTRUCTION
EnergyPro 5.1 by EnergySoft User Number.' 2655 RunCode: 2014-00-04713:13:02 ID: Page 10 of 12
I UAIE BY
MANDATORY MEASURES SUMMARY: Residential (Page 3 of 3 MF-1 R
Project Name
Date
Gipson Residence
1 2/4/2014
§150(k)l0: Permanently installed luminaires in bathrooms, attached and detached garages, laundry rooms, closets and utility rooms
shall be high efficacy.
EXCEPTION 1: Permanently installed low efficacy luminaires shall be allowed provided that they are controlled by a manual-on
occupant sensor certified to comply with the applicable requirements of §119.
EXCEPTION 2: Permanently installed low efficacy luminaires in closets less than 70 square feet are not required to be controlled by a
manual-on occupancy sensor.
§150(k)l 1: Permanently installed luminaires located in rooms or areas other than in kitchens, bathrooms, garages, laundry rooms,
closets, and utility rooms shall be high efficacy luimnaires. EXCEPTION 1: Permanently installed low efficacy luminaires shall be
allowed provided they are controlled by either a dimmer switch that complies with the applicable requirements of §119, or by a manual-
on occupant sensor that complies with the applicable requirements of §119. EXCEPTION 2: Lighting in detached storage building less
than 1000 square feet located on a residential site is not required to comply with §150 k 11.
§150(k)12: Luminaires recessed into insulated ceilings shall be listed for zero clearance insulation contact (IC) by Underwriters
Laboratories or other nationally recognized testing/rating laboratory; and have a label that certifies the lumiunaire is airtight with air
leakage less then 2.0 CFM at 75 Pascals when tested in accordance with ASTM E283; and be sealed with a gasket or caulk between
the luminaire housing and ceiling.
§150(k)13: Luminaires providing outdoor lighting, including lighting for private patios in low-rise residential buildings with four or more
dwelling units, entrances, balconies, and porches, which are permanently mounted to a residential building or to other buildings on the
same lot shall be high efficacy. EXCEPTION 1: Permanently installed outdoor low efficacy luminaires shall be allowed provided that
they are controlled by a manual on/off switch, a motion sensor not having an override or bypass switch that disables the motion sensor,
and one of the following controls: a photocontrol not having an override or bypass switch that disables the photocontrol; OR an
astronomical time clock not having an override or bypass switch that disables the astronomical time clock; OR an energy management
control system (EMCS) not having an override or bypass switch that allows the luminaire to be always on EXCEPTION 2: Outdoor
luminaires used to comply with Exceptionl to §150(k)13 may be controlled by a temporary override switch which bypasses the motion
sensing function provided that the motion sensor is automatically reactivated within six hours. EXCEPTION 3: Permanently installed
luminaires in or around swimming pool, water features, or other location subject to Article 680 of the California Electric Code need not
be high efficacy luminaires.
§150(k)14: Internally illuminated address signs shall comply with Section 148; OR not contain a screw-base socket, and consume no
more than five watts of power as determined according to §130(d).
§150(k)15: Lighting for parking lots and carports with a total of for 8 or more vehicles per site shall comply with the applicable
requirements in Sections 130, 132, 134, and 147. Lighting for parking garages for 8 or more vehicles shall comply with the applicable
requirements of Sections 130, 131, 134, and 146.
§150(k)l6: Permanently installed lighting in the enclosed, non-dwelling spaces of low-rise residential buildings with four or more
dwelling units shall be high efficacy luminaires. EXCEPTION: Permanently installed low efficacy luminaires shall be allowed provided
that they are controlled by an occupant sensors certified to comply with the applicable requirements of 119.
CITY OF LA QUINTA
BUILDING& SAFETY DEPT.
APPROVED
FOR CONSTRUCTION
EnergyPro 5.1 by EnergySoft User Number: 2655 RunCode: 20
4- -
Page 11 of 12
HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY
Project Name
Gipson Residence
Date
2/4/2014
System Name
Existing House
Floor Area
1,785
ENGINEERING CHECKS
SYSTEM LOAD
Number of Systems
1
COIL
CFM
Total Room Loads 896
Return Vented Lighting
Return Air Ducts
Return Fan
Ventilation 1 0
Supply Fan
Supply Air Ducts
TOTAL SYSTEM LOAD
COOLING
PEAK
COIL HTG.
PEAK
Heating System
Sensible
Latent
CFM
Sensible
Output per System 70,000
28,978
2,261
588
29,760
Total Output 8tuh 70,000
0
Output Btuh/s ft 39.2
2,457
2,114
Cooling System
0
0
Output per System 58,000
0
0
0
0
Total Output Btuh 58,000
0
2,261
0
Total Output Tons 4.8
2,457
2,114
Total Output Btuh/s ft 32.5
Total Output s ft/Ton 369.3
1 33,892
1 33,988
Air System
CFM per System
1,300
HVAC EQUIPMENT SELECTION
Airflow cfm
1,300
Existing HVAC 46,950 0
70,000
Airflow cfm/s ft
0.73
Airflow cfmrron 269.0
Outside Air %
0.0%
Total Adjusted System Output 46,950 0
(Adjusted for Peak Design conditions)
TIME OF SYSTEM PEAK Aug 3 PM
70,000
Jan 1 AM
Outside Air cfm/s ft 0.00
Note: values above given at ARI conditions
HEATING SYSTEM PSYCHROMETRICS
Airstream Temperatures at Time of Heating Peak
26 OF 68 OF
Outside Air
0 cfm Supply Fan
1,300 cfm
68 OF
68 OF 119 OF
Heating Coil 118 OF
ROOM
70 OF
COOLING SYSTEM PSYCHROMETICS Airstream Temperatures at Time of Cooling Peak
112/78°F 80/59°F
Outside Air
0 cfm
80 / 59 °F"Fn
80/59°F 46/44°F
0
Supply Fan Cooling Coil
1,300 cfm
CITY OF LA 09 IN �
BUILDING & SAFETY DEPT;--M
FOR CONSTRUCTION
48 / 45 OF
OM
78 / 58 OF
EnergyPro5.1 by EnergySoft User Number: 2655 RunCode: 2014x"
0 -04,T 3:13:02 / „
Page 12 of 12